BRR : 10935748
Tender Brief : supply of Oil Filled Service Transformer For Ntpc Singrauli Tpp Oil Filled Service Transformer For Ntpc Singrauli Tpp As Per Nit Documents , 1600Kva, 11Kv/0.433Kv, 3 Phase, 2 Winding, Outdoor, Onan, Z=6.25%, Dyn1, Off Circuit Taps ±5% In Steps Of 2.5% (With Cable Box Type Hv, With Bus-Duct Type Lv And With Solidly Grounded Lvn Termination) , Tank Pressure Test , Tank Vacuum Test , Measurement Of Acoustic Noise Level As Per Nema Tr-1 (Special Test) , Temperature Rise Test At A Tap Corresponding To Maximum Losses. (Gas Chromatography Shall Be Conducted On Oil Sample Taken Before & Immediately A... Read More
Tender Value
₹
Ref. Document
Submission Date
25-11-2025
Participated Bidder List
8 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics | |||||
| 4 | cnet-technologies | Bid Analytics | |||||
| 5 | cnet-technologies | Bid Analytics | |||||
| 6 | cnet-technologies | Bid Analytics | |||||
| 7 | cnet-technologies | Bid Analytics | |||||
| 8 | cnet-technologies | Bid Analytics |
Work Detail
supply of oil filled service transformer for ntpc singrauli tpp oil filled service transformer for ntpc singrauli tpp as per nit documents , 1600kva, 11kv/0.433kv, 3 phase, 2 winding, outdoor, onan, z=6.25%, dyn1, off circuit taps ±5% in steps of 2.5% (with cable box type hv, with bus-duct type lv and with solidly grounded lvn termination) , tank pressure test , tank vacuum test , measurement of acoustic noise level as per nema tr-1 (special test) , temperature rise test at a tap corresponding to maximum losses. (gas chromatography shall be conducted on oil sample taken before & immediately after temp. rise test. gas analysis shall be as per is: 9434 (based on iec: 60567), results will be interpreted as per is: 10593 (based on iec: 60599).result shall be recorded for future reference). , lightning impulse (full & chopped wave) test on windings (as per iec 60076-3) , short circuit test (special test) as per iec 60076-5** , 2000kva, 11kv/0.433kv, 3 phase, 2 winding, outdoor, onan, z=10.0%, dyn1, off circuit taps ±5% in steps of 2.5% (with cable box type hv, with bus-duct type lv and with solidly grounded lvn termination) , tank pressure test , tank vacuum test , measurement of acoustic noise level as per nema tr-1 (special test) , temperature rise test at a tap corresponding to maximum losses. (gas chromatography shall be conducted on oil sample taken before & immediately after temp. rise test. gas analysis shall be as per is: 9434 (based on iec: 60567), results will be interpreted as per is: 10593 (based on iec: 60599).result shall be recorded for future reference). , lightning impulse (full & chopped wave) test on windings (as per iec 60076-3) , short circuit test (special test) as per iec 60076-5** , 2500kva, 11kv/0.433kv, 3 phase, 2 winding, outdoor, onan, z=10.0%, dyn1, off circuit taps ±5% in steps of 2.5% (with cable box type hv, with bus-duct type lv and with solidly grounded lvn termination) , tank pressure test , tank vacuum test , measurement of acoustic noise level as per nema tr-1 (special test) , temperature rise test at a tap corresponding to maximum losses. (gas chromatography shall be conducted on oil sample taken before & immediately after temp. rise test. gas analysis shall be as per is: 9434 (based on iec: 60567), results will be interpreted as per is: 10593 (based on iec: 60599).result shall be recorded for future reference). , lightning impulse (full & chopped wave) test on windings (as per iec 60076-3) , short circuit test (special test) as per iec 60076-5** , 2500kva, 11kv/3.45kv, 3 phase, 2 winding, outdoor, onan, z=6.0%, dyn1, off circuit taps ±5% in steps of 2.5% (with cable box type hv, with bus-duct type lv and with resistance grounded busbar type lvn termination) , tank pressure test , tank vacuum test , measurement of acoustic noise level as per nema tr-1 (special test) , temperature rise test at a tap corresponding to maximum losses. (gas chromatography shall be conducted on oil sample taken before & immediately after temp. rise test. gas analysis shall be as per is: 9434 (based on iec: 60567), results will be interpreted as per is: 10593 (based on iec: 60599).result shall be recorded for future reference). , lightning impulse (full & chopped wave) test on windings (as per iec 60076-3) , lightning impulse on neutral , short circuit test (special test) as per iec 60076-5** , **charges for carrying out short circuit test shall be payable based on actual invoice from designated laboratories (cpri, bhopal/ cpri, banglore / erda, vadodara) with an additional lump sum amount of 5% of ex-works price of transformer being tested to cover handling costs (transportation, insurance etc.). , in case type/ special tests are waived, the type/ special test charges shall not be payable to the bidder , charges for all type/ special tests except short circuit test shall be considered for price comparisons purpose. , in case any of the type/ special tests are required to be repeated the same shall be carried out by the vendor without any commercial / delivery implication to bhel.
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Technical Evaluation In Progress
Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.