BRR : 10852057
Click Here To View Tendering Authority. Technical Bid City/State :  Jammu, Jammu And Kashmir
Tender Brief : Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division Gmch Jammu. Servicing, Maintenance And Repair Of 66 Tr Air Cooled Air Conditioning Chiller Plant No 1 Installed At Terrace Of Library Of Gmc, Jammu Mhdj/E-Nit 405 Of 2025-26 Dated: 18.03.2026 Due : 24.03.2026 Bidder Name : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For Thi... Read More
Tender Value
2,27,500
Submission Date
24-03-2026
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
Work Detail
tender for item rate boq boq_ver3.0 item rate normal inr only inr select, excess (+), less (-) less (-) tender inviting authority: executive engineer, mechanical & hospital division gmch jammu. servicing, maintenance and repair of 66 tr air cooled air conditioning chiller plant no 1 installed at terrace of library of gmc, jammu mhdj/e-nit 405 of 2025-26 dated: 18.03.2026 due : 24.03.2026 bidder name : price schedule (this boq template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. bidders are allowed to enter the bidder name and values only ) number # text # text # number # text # number number text text # number # text# text # number # number number number number text text number number number number text text number number number number text text number number number number text text number number number number text text number number number # number # text text number # number # date number # number # text # sl. no. item code / make quantity units estimated rate addition / deduction rate including gst to be quoted by the bidder rs. p currency convertion against each item quoted currency in inr / other currency rebate on old parts in percentage (%) if any excise duty vat freight charges ( unloading & stacking) any other taxes/duties/levies other taxes 2 iiird party i.e dgs&d / rites etc inspection charges @0.34%+service tax less for cenvat credit,if any respect of supplies under full excise duty category net cost of item rs. p total amount total amount with taxes total amount in words , servicing, maintenance and repair of 66 tr air cooled air conditioning chiller plant no 1 installed at terrace of library of gmc, jammu by way of disconnecting of electrical connections and holding the water supply by closing the butterfly valves of chiller pipeline. the job includes disconnecting of damaged motherboard with display- rev 11.1 of mcs magnum make. job includes removing the motherboard with display from its installed position and sending to workshop for repairs and calibration of same so that it should be compatible to connect to the pc and on site loading of software and programme as per the heat load the mother board should be able to control and regulate the operation of screw compressor , multiple liquid lines solenoid, electronic expansion valves , liquid injection and economizers. the job includes providing and fitting of in and out temperature sensors of condenser line in place of damaged ones. the job includes opening of fan motors of 1.5 kw capacity and sending to workshop for repairs/rewinding of coil and fitting back after repairs. the job also includes recovering of the refrigerant gas r-407 from the unit with the help of vaccum pump and storing in cylinders . the job also includes the testing of leakages in the chiller plant by filling nitrogen gas in the unit to a pressure of 1.5 times of operating pressure of plant and retained for 24 hrs. during the retention period, the leakages, if any, are checked by soap bubble detection test. then plugging the leakages with help of copper brazing method and replacement of nipples etc then flushing out the old contaminated compresser oil and filling fresh polyolester compresser oil 20 ltrs approx in all the 6 compressors then recharging the plant with refrigerant gas r-407- 30 kg and stored refrigerant gas r-407 also and fitting the repaired mother board in its original position and opening the butterfly valves to circulate water and then making all the electrical connections testing of chillar plant on no load and on full load. complete job includes cost of materiai, labour, transportation and all types of taxes etc. total in figures 23 23 0.0 23 inr zero only quoted rate in figures select 0.0 0.0 zero only quoted rate in words inr zero only
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 153d1b25-b86c-4e64-8ba7-5dc80c283911 technicalevaluation notice
Download techsummary_994952 document
Download File Name File Description
Download 38fcd71b-4f46-42c6-824f-af4f22a6b17e Tender Documents
Download BOQ_994952 Tender Documents
Download Tendernotice_1 (4) Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Technical Evaluation In Progress

Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.

TechnicalBid
Similar Tenders Results
TenderDetail
Loading tenders