BRR : 10842842
Click Here To View Tendering Authority. Aoc City/State :  CHITTORGARH, Rajasthan
Tender Brief : Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220Kv Switchyard Three Phase Manual Isolators (Ds) Preventative Maintenance (Total Quantity 1 Is Equal To 19 Numbers .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220Kv Switchyard Three Phase Motorized Isolators (Ds) Preventative Maintenance (Total Quantity 1 Is Equal To 17 Numbe.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (... Read More
Tender Value
29,00,810
Contract Value
₹ 26,39,685
Saving / Difference
₹ 2,61,125 ▲
Submission Date
14-01-2026
Contract Date
Ref. Document
Completion Date
Ref. Document
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics 26,39,685 L1
Work Detail
bids are invited for repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard three phase manual isolators (ds) preventative maintenance (total quantity 1 is equal to 19 numbers .. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard three phase motorized isolators (ds) preventative maintenance (total quantity 1 is equal to 17 numbe.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, assistance in preventative maintenance of three phase 220kv sf6 circuit breaker (total quantity 1 is equal to 10 numb.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, assistance in preventative maintenance of 132 kv three phase mocb (total quantity 1 is equal to 2 numbers for t.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, cleaning and tightness of 220 kv switchyard single tension / suspension string for single conductor (total quantity 1.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, cleaning and tightness of 220 kv switchyard double insulator suspension string for single conductor (total quantity 1.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard overhead connectors (t connection), clamp / joints inspection, cleaning and tightness checks and rep.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard overhead connectors (y connection), clamp / joints inspection, cleaning and 1 tightness checks and rep.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv line tension insulator cleaning and tightness of wall bracket for support at tb wall (total quantity 1 is equal.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, cleaning and tightness of sky ground wire connections (tower top and ground) (total quantity 1 is equal to 51 set for.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard insulators cleaning, inspection and connection tightness of ct / pt / cvt / la / sut / gt hv bushin.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, assistance for disconnection and connection of 220kv ct / pt / cvt / gt / sut / ut terminals for diagnostic testing o.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv line wave trap cleaning, inspection and connection tightness (total quantity 1 is equal to 7 numbers for two ye.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard bus post insulators (vertically mounted on ground) cleaning, inspection and connection tightness (to.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 21 kv isolated phase bus duct cleaning, inspection and connection tightness and replacement of gasket and sealing etc.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard overhead aac strained all aluminum conductor / jumper replacement up to twenty meter length piece (t.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, replacement of 132 kv la (total quantity 1 is equal to 6 numbers for two years); as per scope of work and atc , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, replacement of single tension / suspension string / wave trap (of 220kv switchyard) for single conductor (total quant.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, replacement of double insulator suspension string set (of 220kv switchyard) for single conductor (total quantity 1 is.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, replacement of 220kv switchyard bus post insulator (total quantity 1 is equal to 2 numbers for two years); as per sco.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, replacement of insulator of 220kv switchyard isolator (ds) / ct / pt / cvt) i.e. complete unit of one phase (total qu.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, replacement of sky wire (60 meter length each) of 220kv switchyard (total quantity 1 is equal to 5 numbers for two ye.. , repair, maintenance, and installation of plant/ 2 total quantity : repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard three phase manual isolators (ds) preventative maintenance (total quantity 1 is equal to 19 numbers .. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard three phase motorized isolators (ds) preventative maintenance (total quantity 1 is equal to 17 numbe.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, assistance in preventative maintenance of three phase 220kv sf6 circuit breaker (total quantity 1 is equal to 10 numb.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, assistance in preventative maintenance of 220 / 132 kv three phase mocb (total quantity 1 is equal to 2 numbers for t.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, cleaning and tightness of 220 kv switchyard single tension / suspension string for single conductor (total quantity 1.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, cleaning and tightness of 220 kv switchyard double insulator suspension string for single conductor (total quantity 1.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard overhead connectors (t connection), clamp / joints inspection, cleaning and tightness checks and rep.. , repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard overhead connectors (y connection), clamp / joints inspection, cleaning and 1
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 458b42b5-4fb2-4a08-8f2b-c9df4e1e8ef3 result notice
Download File Name File Description
Download 1764929357 Tender Documents
Download 1764929503 Tender Documents
Download 0b0870f9-0f85-4d0f-ae7c-6033aa109e3b Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders