BRR : 10842228
Tender Brief : Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Rfp; As Per Rfp; Buyer- 1 Handling And Dragging Of Transformer From Stacking Yard To Repairing Hall. 1.01 10Kva 1.02 25Kva 1.03 63Kva 1.04 100Kva 2 Cutting Of Sealed Transformers Top Cover Plate Smoothly And Uniformally By Gas/Chisel Cutter Or Opening Of Top Cover Plat And Detanking Of Core And Coil Assembly. 2.01 10Kva 2.02 25Kva 2.03 63Kva 2.04 100Kva 3 Dragging Of The Tank From The Repaired Hall To Yard. & Cleaning Oil And Dust Etc. And Scraping The Rust Etc And Washing Of Transform... Read More
Tender Value
₹
48,08,000
Contract Value
₹ 46,85,595.33
Saving / Difference
₹ 1,22,405
▲
Submission Date
16-03-2026
Contract Date
Ref. Document
Completion Date
Ref. Document
Participated Bidder List
3 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 48,28,294.5 | L2 | |||
| 2 | cnet-technologies | Bid Analytics | 62,70,335.92 | L3 | |||
| 3 | cnet-technologies | Bid Analytics | 46,85,595.33 | L1 |
Work Detail
bids are invited for repair, maintenance, and installation of plant/ systems/equipments (version 2) - as per rfp; as per rfp; buyer- 1 handling and dragging of transformer from stacking yard to repairing hall. 1.01 10kva 1.02 25kva 1.03 63kva 1.04 100kva 2 cutting of sealed transformers top cover plate smoothly and uniformally by gas/chisel cutter or opening of top cover plat and detanking of core and coil assembly. 2.01 10kva 2.02 25kva 2.03 63kva 2.04 100kva 3 dragging of the tank from the repaired hall to yard. & cleaning oil and dust etc. and scraping the rust etc and washing of transformer tank with caustic soda & water, caustic soda shall be provided by contractor 3.01 10kva 3.02 25kva 3.03 63kva 3.04 100kva 4 painting of inner side of transformer tank and channels with heat proof zinc chromate paint of good quality (berger, nerolac, jenson & nicholson etc) shall be 4.01 10kva 4.02 25kva 4.03 63kva 4.04 100kva 5 dragging out empty tank from yard to repairing hall. 5.01 10kva 5.02 25kva 5.03 63kva 5.04 100kva 6 dismantling core and coil assembly and cleaning of dust and dirt from the core assembly and checking of lv and hv leg coils for assessing its reuse, rechecking and recording of physical dimensions of coil and cleaning of core and their components etc. 6.01 10kva 6.02 25kva 6.03 63kva 6.04 100kva 7 reconditioning of minor damaged in hv/lv leg coil/ strip of transformer. work includes removing of damage part dpc insulation and providing new dpc on same hv coil/lv strip should be properly cleaned and should be made of same size as of original . 7.01 25kva 7.02 63kva 7.03 100kva 8 ‘‘making of complete lv leg alu. leg coils identical to original one with same number of turns, weight etc providing super enameled / dpc conductor/ strip confirming to is 1971 /53 in place of old and damage coil. alu. coil, wire strip will be provided by the department. all coil assembly of identical voltage shall be interchangeable without requiring any special equipment. coil shall be supported between adjacent sections by insulations, spacers, beamers and other insulations.rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. the insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of winding as per original design. 8.01 10kva 8.02 25kva 8.03 63kva 8.04 100kva 9 ‘‘making of complete hv leg alu. leg coils identical to original one with same number of turns, weight etc providing super enameled / dpc conductor/ strip confirming to is 1971 /53 in place of old and damage coil. alu. coil, wire strip will be provided by the department. all coil assembly of identical voltage shall be interchangeable without requiring any special equipment. coil shall be supported between adjacent sections by insulations, spacers, beamers and other insulations.rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. the insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of winding as per original design. 9.01 10kva 9.02 25kva 9.03 63kva 9.04 100kva 10 assembly of core and coils and fitting of other parts requiring replacement such as press board, making supports between adjacent sections by insulating spares and rapping etc & tapping etc. (breezing/soldering) required, shall be arrange by the contractor. 10.01 10kva 10.02 25kva 10.03 63kva 10.04 100kva 11 shifting and keeping the assembled core coil etc. in oven from the repairing and assembly place.
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | 4002a1c4-5c21-4f2e-b959-f2633d941b74 | result notice |
| Download | File Name | File Description |
|---|---|---|
| Download | ff1d75fe-1f18-41c3-9de4-f04f43ff8cee | Tender Documents |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results