Tender Brief : GENERAL-Anad G P Electrical works-Electrical work in kolla lps 35/25-General Electrical Work--- 1 Electrification 2 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare cop... Read More
Tender Value
81,334
Submission Date
19-09-2025
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 71,980.94 L1
2 cnet-technologies Bid Analytics
Work Detail
general-anad g p electrical works-electrical work in kolla lps 35/25-general electrical work--- 1 electrification 2 90.2.1.1:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).single control light point with 6a, plate ceiling rose - short point 3 90.2.1.4:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).single control ceiling fan point with 6 a, 3 plate ceiling rose & with socket size stepped electronic regulator. - short point 4 90.2.1.6:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).combined plug point with 6 a, 5 pin plug socket controlled by 6 a, switch in the same switch board as that of light points 5 90.2.1.7:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).independent plug - short point 6 1.32:supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 7 1.56:supplying and fixing suitable size gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 a modular socket outlets and 2 nos. 5/6 a modular switches, connection etc. as required. (for light plugs to be used in non residential buildings). 8 od214663/2025-2026:supply conveyance, installation, testing and commissioning the light fittings of following types made of poly carbonate material, cri>80, colour temperature: 6500 k, luminous efficiency>=100 lm / w directly on wall and giving connections with 16/0.20 mm 3 core pvc insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.1200 mm 36-40 w led batten 9 90.4.1:supply and installation of suitable size ms rod type fan clamp in the rcc slab as per is 732 as required. 10 90.4.5.4:supply, installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/watt), air delivery minimum 210(cubic meter/minute), copper winding suitable for 230v/240v single phase ac supply 11 1.21.1:supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 12 1.17.3:supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.3 x 1.5 sq.mm 13 1.17.12:supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.3 x 2.5 sq. mm 14 1.17.21:supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.3 x 4 sq. mm 15 2.3.3:supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 12 way, double door 16 2.10.1:supplying and fixing 5a to 32 a rating, 240/415 volts, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole 17 2.12.1:supplying and fixing following rating, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.40 amps 18 2.14.2:supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (rccb), having a sensitivity current 30 milli amperes in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 amps 19 5.1:earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. 20 90.16.1.3:supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 swg) 21 90.16.5.3:supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 swg) 22 90.14.1.2:fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type mv panel board comprising of the following components/ devices & complying to is 8623. fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of is 8623 (with latest amendments) using crca sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. crca sheet alone be used for the fabrication. angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. the measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.supply and fabrication of mv panel board using 1.6mm crca sheet, powder coated (excluding base frame) 23 od214662/2025-2026:supply and fixing 32 a, 2 way neutral links mounted on dmc/smc base 24 od214661/2025-2026:supplying and fixing 32a, hrc bakelite fuse fittings with hrc fuse link with connections, in existing meter board
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download ac5ccb0e-58c8-4e35-9dcd-2b8dbcb14bf0 financialevaluation notice
Download boqcomparativechart boq document
Download finance_1318676 aoc document
Download finsummary_1318676 aoc document
Download File Name File Description
Download e29f07b3-4b11-40b3-b641-b9b8ec3022c1 Tender Documents
Download BOQ_1318676 Tender Documents
Download Tendernotice_1 Tender Documents
Download viewsbd Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.

PriceBid
Similar Tenders Results
TenderDetail
Loading tenders