BRR : 10792439
Click Here To View Tendering Authority. Price Bid City/State :  gelling, Arunachal Pradesh
Tender Brief : Tender For Construction Of Sos And Ors Living Accommodation At Bop Gelling Of 49 Bn Itbp; 1 Earth workexcavation by manual means over area ( exceeding 30 cm in depth1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.: All kind of soil 2 Excavation work in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dresing of sides and ramming of bottoms lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils... Read More
Tender Value
2,41,70,861
Submission Date
06-12-2025
Participated Bidder List
5 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 1,78,88,854 L1
2 cnet-technologies Bid Analytics 2,34,45,735 L5
3 cnet-technologies Bid Analytics 2,01,10,156 L3
4 cnet-technologies Bid Analytics 1,81,28,146 L2
5 cnet-technologies Bid Analytics 2,19,22,971 L4
Work Detail
tender for construction of sos and ors living accommodation at bop gelling of 49 bn itbp; 1 earth workexcavation by manual means over area ( exceeding 30 cm in depth1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.: all kind of soil 2 excavation work in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dresing of sides and ramming of bottoms lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed , within a lead of 50 m.all kind of soil 3 filling available excavated earth ( excluding rocks) in plinth side of foundation, under floors in layers not exceeding 20 cm in depthincluding, watering, ramming consolidating and dressing completelead up to 50 m and lift up to 1.5 m 4 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - all work upto plinth level :1:2:4 (1 cement : 2 coarse sand (zone-iii) : 4 graded stone aggregate 20 mm nominal size) 5 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - all work upto plinth level :1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 6 providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete :. cement ordinary portland43 grade conforming to is no: 8112- 1989:1:1½:3 (1 cement: 1½ coarse sand(zone-iii) : 3 graded stone aggregate 20 mm nominal size) 7 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm bed by dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth 8 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size) 9 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size) 10 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarsesand (zone-iii) : 3 graded stone aggregate 20 mm nominal size). 11 centering and shutturing incl. strutting, proping etc and removal of form work for all heights:foundations, footings, bases of columns, etc. for mass concrete 12 centering and shutturing incl. strutting, proping etc and removal of form work for all heights:suspended floors, roofs, landings, balconies and access platform 13 centering and shutturing incl. strutting, proping etc and removal of form work for all heights: lintels, beams, plinth beams, girders, bressumers and cantilevers 14 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.thermo-mechanically treated bars of grade fe-500d or more 15 random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : cement mortar 1:6 (1 cement : 6 coarse sand) 16 random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) above plinth level with : cement mortar 1:6 (1 cement : 6 coarse sand) 17 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) with first class local wood(tita champa / pine/tiger): local wood 18 providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :first class local wood(tita champa / pine) 19 providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including isi marked m.s. pressed butt hinges bright finished of required size with necessary screws: first class local wood (tita champa/pine/tiger)-35mm thick 20 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 21 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws; 35 mm thick shutters: with isi marked m.s. pressed butt hinges bright finished of required size: first class local wood (tita champa/pine/tiger) 22 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. complete.: fixed to windows openings/wooden frame with screws 23 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than gradeac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm 24 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than gradeac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10mm 25 providing and fixing aluminium tower bolt100x10mm 26 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than gradeac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :size 125mm 27 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than gradeac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : size 100 mm 28 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than gradeac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.: twin rubber stopper 29 providing and fixing aluminium casement stays, isi marked, anodised (anodic coating not less than gradeac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 30 structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 31 providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only .laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. glazed vitrified tiles matt/antiskid finish of size. size of tile600 x 600 mm 32 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 33 extra for providing and fixing wind ties of 40x 6 mm flat iron section. 34 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineerin-charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 35 providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (tct), zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete :ridges plain (500 - 600mm) 36 providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (tct), zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete :barge board/eave board on roof edge 37 12mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 38 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 39 distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer , of required shade and colour complete, as per manufacturers specification. : two or more coats on new work 40 applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : water thinnable cement primer 41 finishing walls withacrylic smooth exterior paint of required shade : new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 42 applying priming coat with: with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 43 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work 44 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete. 45 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group b 46 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 47 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.: 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 48 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 49 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 a & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required 50 supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box/ wooden block including connections etc. as required. 51 supplying and fixing pvc batten/ angle holder including connections etc. as required. 52 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator):8 way, double door 53 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 54 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 63 amp 55 sitc of 1200mm 5 star rated ceiling fan for 230v 50hz ac supply including wiring the down rods of standerd lenth (up to 300mm) with 1.5sqmm frls pvc insulated copper conductor single core cable(excel star 1200mm white ceiling fan) 56 sitc of surface mounted 20 watt led batten (4 ft) with wiring up to terminal block connection complete etc. as reqd. 57 sitc of 5 watt led batten (1 ft) surface mounting mirror light fitting having white colour along with 1.5sqmm frls pvc copper conductor single core cable earthing as per reqd. 58 supplying & laying of one number pvc insulated and pvc sheathed / xlpe aluminium conductor armoured electric cable 3.5 core 35 sqmm of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required .(brand should be used (havells / grandley / plaza / kalinga / national) 59 supplyingandlayingoffollowingsizedwchdpe pipe isi marked along with all accessories like socket, bend,couplersetc. conformingto is14930,partii complete with fitting and cutting, jointing etc.direct in ground(75cmbelowgroundlevel)including excavation and refilling the trench but excluding sand cushioningandprotectivecoveringetc.,completeas required. 63 mm dia (od-63 mm & id-50 mm nominal) 60 sitc of solar street light 30 watt white led with wiring up to terminal block connection complete etc. as reqd.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 43fc9725-b8fb-47f0-b1f5-50c9ac4095f6 financialevaluation notice
Download boqcomparativechart boq document
Download finsummary_930035 aoc document
Download File Name File Description
Download 627c317b-6f63-4fe5-895f-898d1fe5d0be Tender Documents
Download Tendernotice_2 Tender Documents
Download BOQ_930035 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.

PriceBid
Similar Tenders Results
TenderDetail
Loading tenders