BRR : 10646064
Tender Brief : Procurement Of Mccb And Mcb Of Different Ratings . As Per Nit , 3 Pole Mccb With Thermal Magnetic Trip Unit , Ics=100% Icu , Adjustable Thermal/Overload Setting , Breaking Capacity@ 415V , 50Hz 25Ka , Rated Current 32A . Make: Siemens , Schneider & Abb Only . . , 3 Pole Mccb With Thermal Magnetic Trip Unit , Ics=100% Icu , Adjustable Thermal/Overload Setting , Breaking Capacity@ 415V , 50Hz 25Ka , Rated Current 63A . Make: Siemens , Schneider & Abb Only . , 3 Pole Mccb With Thermal Magnetic Trip Unit , Ics=100% Icu , Adjustable Thermal/Overload Setting , Breaking Capac... Read More
Tender Value
₹
Ref. Document
Submission Date
10-07-2020
Participated Bidder List
2 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 16,272 | L1 | |||
| 2 | cnet-technologies | Bid Analytics | 7,40,840 | L1 |
Work Detail
procurement of mccb and mcb of different ratings . as per nit , 3 pole mccb with thermal magnetic trip unit , ics=100% icu , adjustable thermal/overload setting , breaking capacity@ 415v , 50hz 25ka , rated current 32a . make: siemens , schneider & abb only . . , 3 pole mccb with thermal magnetic trip unit , ics=100% icu , adjustable thermal/overload setting , breaking capacity@ 415v , 50hz 25ka , rated current 63a . make: siemens , schneider & abb only . , 3 pole mccb with thermal magnetic trip unit , ics=100% icu , adjustable thermal/overload setting , breaking capacity@ 415v , 50hz 25ka , rated current 100a . make: siemens , schneider & abb only . . , 3 pole mccb with thermal magnetic trip unit , ics=100% icu , adjustable thermal/overload setting , breaking capacity@ 415v , 50hz 25ka , rated current 160a . make: siemens , schneider & abb only . , 3 pole mccb with thermal magnetic trip unit , ics=100% icu , adjustable thermal/overload setting , breaking capacity@ 415v , 50hz 36ka , rated current 200a . make: siemens , schneider & abb only . , 3 pole mccb with thermal magnetic trip unit , ics=100% icu , adjustable thermal/overload setting , breaking capacity@ 415v , 50hz 36ka , rated current 250a . make: siemens , schneider & abb only . , 3 pole mccb with thermal magnetic trip unit , ics=100% icu , adjustable thermal/overload setting , breaking capacity@ 415v , 50hz 36ka , rated current 400a . make: siemens , schneider & abb only . , 3 pole mccb with thermal magnetic trip unit , ics=100% icu , adjustable thermal/overload setting , breaking capacity@ 415v , 50hz 36ka , rated current 500a . make: siemens , schneider & abb only . , 2 pole ac mcb , breaking capacity as per iec 60898-1 , characteristic c , current rating 2a . make: siemens , schneider & abb only . , 2 pole ac mcb , breaking capacity as per iec 60898-1 , characteristic c , current rating 4a . make: siemens , schneider & abb only . , 2 pole ac mcb , breaking capacity as per iec 60898-1 , characteristic c , current rating 6a . make: siemens , schneider & abb only . , 2 pole ac mcb , breaking capacity as per iec 60898-1 , characteristic c , current rating 10a . make: siemens , schneider & abb only . , 2 pole ac mcb , breaking capacity as per iec 60898-1 , characteristic c , current rating 16a . make: siemens , schneider & abb only . , 3 pole ac mcb , breaking capacity as per iec 60898-1 , characteristic c , current rating 25a . make: siemens , schneider & abb only . , 3 pole ac mcb , breaking capacity as per iec 60898-1 , characteristic c , current rating 32a . make: siemens , schneider & abb only . , 3 pole ac mcb , breaking capacity as per iec 60898-1 , characteristic c , current rating 40a . make: siemens , schneider & abb only . , 3 pole ac mcb , breaking capacity as per iec 60898-1 , characteristic c , current rating 50a . make: siemens , schneider & abb only . , 3 pole ac mcb , breaking capacity as per iec 60898-1 , characteristic c , current rating 63a . make: siemens , schneider & abb only .
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Financial Evaluation In Progress
Financial bids are currently under review. Awarded bidder information will be published after final evaluation.
PriceBid
Similar Tenders Results