BRR : 10591979
Click Here To View Tendering Authority. Price Bid City/State :  gonda, Uttar Pradesh
Tender Brief : tender for Work for rewinding & overhauling of cooling fans of transformers, replacement of gaskets in marshalling boxes alongwith other associated worksat132 KV substation Colonelganj under Electricity Trans. Division Gonda Sl. No. Item Description 1 Rewinding of 3 phase 440 volt, 0.5 HP capacity cooling fans of power transformers. The work includes dismantling of cooling fans from the transformers, its carriage to repair workshop & back after due rewinding. Replacement of defective ball bearings oiling, greasing etc and finally mounting of cooling fans on the transformers with proper ele... Read More
Tender Value
Ref. Document
Submission Date
04-01-2025
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 1,67,500 L1
2 cnet-technologies Bid Analytics 1,80,000 L3
3 cnet-technologies Bid Analytics 1,79,000 L2
Work Detail
tender for work for rewinding & overhauling of cooling fans of transformers, replacement of gaskets in marshalling boxes alongwith other associated worksat132 kv substation colonelganj under electricity trans. division gonda sl. no. item description 1 rewinding of 3 phase 440 volt, 0.5 hp capacity cooling fans of power transformers. the work includes dismantling of cooling fans from the transformers, its carriage to repair workshop & back after due rewinding. replacement of defective ball bearings oiling, greasing etc and finally mounting of cooling fans on the transformers with proper electrical connection for satisfactory running as per details given below: 2 40 mva t/f- i, ii and iii at 132 kv substation colonelganj. 3 overhauling & servicing of 3 phase, 440 volt, o.5 hp capacity cooling fans of power transformers. the work includes dismantling of the cooling fan from the transformers its carriage to repair workshop & back after due replacement of defective ball bearing, oiling, greasing etc and finally mounting of the coolng fans on the transformers with proper electrical connection for satisfactory running as per details given below: 4 40 mva t/f- i and ii at 132 kv substation colonelganj. 5 replacement of damaged rubber gaskets and glass 6 mm thick in the door of marshalling boxes of transformers by providing & fixing of rubber gaskets of same size for making its dust & vermin proof & glass. 6 for 40 mva t/f- iii at 132 kv substation colonelganj. 7 providing & fixing of 415 volt ac 10amp 4 pole power contactor alongwith auxiliary contact (as per smple-l&t make) including proper electrical connection as per drawing for satisfactory automated running of cooling fans as per details given below: 8 40 mva t/f- i at 132 kv substation colonelganj. 9 p&f of thermal o/l relay (as per smple) including proper electrical connection as per drawing for satisfactory automated running of cooling fans as per details given below: 10 40 mva t/f- i and ii at 132 kv substation colonelganj.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 8cfec8ca-a604-43b9-9b07-25257d445e03 financialevaluation notice
Download boqcomparativechart boq document
Download finance_1725680 aoc document
Download finsummary_1725680 aoc document
Download File Name File Description
Download e31a6fee-2d03-4784-975d-78616baed9de Tender Documents
Download BOQ_1725680 Tender Documents
Download RETD10 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.