BRR : 10577775
Click Here To View Tendering Authority. Price Bid City/State :  bikaner, Rajasthan
Tender Brief : Supply Of Disposable Surgical And Chemicals For Dialysis Department Supply Of Disposable Surgical And Chemicals For Dialysis Department , Dialyzer Should Be Synthetic Membrane ( Polysulfone Or Poly Ethersulfone ) Effective Surface Area 1.1 Sqm , Dialyzer Should Be Synthetic Membrane ( Polysulfone Or Poly Ethersulfone ) Effective Surface Area 1.3 Sqm , Dialyzer With Blood Tubing Set Dialyzer Should Be Synthetic Membrane ( Polysulfone Or Poly Ethersulfone ) Blood Tubing Set Must Be Same Company Of Dialyzer Effective Surface Area 1.4 Sqm , Dialyzer With Blood Tubing Set Dialyzer Should Be... Read More
Tender Value
1,20,00,000
Submission Date
01-08-2022
Participated Bidder List
5 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 22,683 L1
2 cnet-technologies Bid Analytics 18,297.6 L1
3 cnet-technologies Bid Analytics 9,995.35 L1
4 cnet-technologies Bid Analytics 12,445 L1
5 cnet-technologies Bid Analytics 24,038 L2
Work Detail
supply of disposable surgical and chemicals for dialysis department supply of disposable surgical and chemicals for dialysis department , dialyzer should be synthetic membrane ( polysulfone or poly ethersulfone ) effective surface area 1.1 sqm , dialyzer should be synthetic membrane ( polysulfone or poly ethersulfone ) effective surface area 1.3 sqm , dialyzer with blood tubing set dialyzer should be synthetic membrane ( polysulfone or poly ethersulfone ) blood tubing set must be same company of dialyzer effective surface area 1.4 sqm , dialyzer with blood tubing set dialyzer should be synthetic membrane ( polysulfone or poly ethersulfone ) blood tubing set must be same company of dialyzer effective surface area 1.5 sqm , dialyzer should be synthetic membrane ( polysulfone or poly ethersulfone ) effective surface area 1.6 sqm , dialyzer with blood tubing set dialyzer should be synthetic membrane ( polysulfone or poly ethersulfone ) blood tubing set must be same company of dialyzer effective surface area 1.8 sqm , pediatric dialyzer with pediatric blood tubing dialyzer should be synthetic membrane ( as polysulfone or poly ethersulfone ) effective surface area 0.6 sqm , pediatric dialyzer with pediatric blood tubing dialyzer should be synthetic membrane ( as polysulfone or poly ethersulfone ) effective surface area 0.8 sqm , double lumen catheter with kit curved / straight catheter should be made of flexible radio opaque polyurethane with a radio opaque tip ( easy visualization in x ray ) accessory shuold be provided as contains ( catheter, dilator, introducer needle syringe, guide wire with dispenser and inj. caps ) catheter should be usfda approved ( certificate must be enclosed. ) size 11.5 / 12fr x 13 cm , double lumen catheter with kit internal jugular curved / straight catheter should be made of flexible radio opaque polyurethane with a radio opaque tip ( easy visualization in x ray ) accessory shuold be provided as contains ( catheter, dilator, introducer needle syringe, guide wire with dispenser and inj. caps ) catheter should have usfda approved ( certificate must be enclosed. ) size 8.5 / 09fr x 11 cm , double lumen catheter with kit internal jugular curved / straight catheter should be made of flexible radio opaque polyurethane with a radio opaque tip ( easy visualization in x ray ) accessory shuold be provided as contains ( catheter, dilator, introducer needle syringe, guide wire with dispenser and inj. caps ) catheter should have usfda approved ( certificate must be enclosed. ) size 10fr x 12 cm , double lumen catheter with kit internal jugular curved / straight catheter should be made of flexible radio opaque polyurethane with a radio opaque tip ( easy visualization in x ray ) accessory shuold be provided as contains ( catheter, dilator, introducer needle syringe, guide wire with dispenser and inj. caps ) catheter should have usfda approved ( certificate must be enclosed. ) size 11.5 x 12 fr x 16 / 15cm , disposable biopsy gun needle automated spring loaded presterile size 16g / 18g- needle should be us fda approved ( certificate must be enclosed ) it should have sample notch size 1.8 cm and 1.9 cm.it should have non roll handle design. , a.v fistula needle 16g rotating wing tuype having back eye , a.v fistula needle 17g rotating wing tuype having back eye , haemo dialysis solution fluid concentrate ( part a ) 10 ltr with bicarbonate powder 2 pkt ( part-b ) , h.d fluid high concentrate part a compatible with bibag- company must be iso and gmp certified ( certificate must be enclosed ) , hot sterlilzation solution 5 ltr jar solution should be effective for cleaning bil film calcium magnesium deposited to reduce haemo dialysis machine breakdown and use for machine disinfection , sodium hypochlorite soloution:- concentrate in 5ltr can , acetic - acid soloution:- concentrate in 5ltr can , hydrochloric acid solution:- concentrate in 5ltr can , citrosteril solution ( 5ltr ) :- , high flux dialyzer :- effective surface area - 0.9 m2 specification :- 1. dialyzer should be of a reputed international make:- 2. must be european ce from a notified body / usfda certified ( certificate must be enclosed ) 3. inside diameter of fiber should be 200 micro meter. 4.it should using the sterilization method of steam / gamma , high flux dialyzer :- effective surface area - 1.1 m2 specification :- 1. dialyzer should be of a reputed international make:- 2. must be european ce from a notified body / usfda certified ( certificate must be enclosed ) 3. inside diameter of fiber should be 200 micro meter. 4.it should using the sterilization method of steam / gamma. , high flux dialyzer :- effective surface area - 1.4 m2 specification :- 1. dialyzer should be of a reputed international make:- 2. must be european ce from a notified body / usfda certified ( certificate must be enclosed ) 3. inside diameter of fiber should be 200 micro meter. 4.it should using the sterilization method of steam / gamma , high flux dialyzer :- effective surface area - 1.5 m2 specification :- 1. dialyzer should be of a reputed international make:- 2. must be european ce from a notified body / usfda certified ( certificate must be enclosed ) 3. inside diameter of fiber should be 200 micro meter. 4.it should using the sterilization method of steam / gamma. , high flux dialyzer :- effective surface area - 1.7 m2 specification :- 1. dialyzer should be of a reputed international make:- 2. must be european ce from a notified body / usfda certified ( certificate must be enclosed ) 3. inside diameter of fiber should be 200 micro meter. 4.it should using the sterilization method of steam / gamma. , high flux dialyzer :- effective surface area - 1.9 m2 specification :- 1. dialyzer should be of a reputed international make:- 2. must be european ce from a notified body / usfda certified ( certificate must be enclosed ) 3. inside diameter of fiber should be 200 micro meter. 4.it should using the sterilization method of steam / gamma.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 50e41cbe-3ccf-41b1-b5d6-695599b42718 financialevaluation notice
Download boqcomparativechart boq document
Download finsummary_509988 aoc document
Download File Name File Description
Download be588484-8dbe-4c07-8237-b8c4e71bc188 Tender Documents
Download BOQ_509988 Tender Documents
Download item1 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.

PriceBid
Similar Tenders Results
TenderDetail
Loading tenders