BRR : 10383541
Tender Brief : Tender For Erection Of Electricity Lines Under Deposit Head In The Area Of Edd, Jalesar, Etah Under Edc Etah - Safe carriage of 8.5 mtr. Long PCC pole from store center Etah 33/11 KV S/S to direct pit site in distance range 0 to 60 Km including loading & unloading at both ends. 2 Safe carriage of 11/13 mtr. long ST pole from store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 60 Km. including loading & unloading at both ends. 3 Safe carriage of line material from store center Etah to pit site in distance range 0 to 60 km including loading & unloading at both end... Read More
Tender Value
₹
10,00,000
Submission Date
27-05-2025
Participated Bidder List
3 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 9,98,750 | L1 | |||
| 2 | cnet-technologies | Bid Analytics | 10,29,470 | L2 | |||
| 3 | cnet-technologies | Bid Analytics | 10,33,250 | L3 |
Work Detail
tender for erection of electricity lines under deposit head in the area of edd, jalesar, etah under edc etah - safe carriage of 8.5 mtr. long pcc pole from store center etah 33/11 kv s/s to direct pit site in distance range 0 to 60 km including loading & unloading at both ends. 2 safe carriage of 11/13 mtr. long st pole from store center etah/nearest 33/11 kv s/s to direct pit site in distance range 0 to 60 km. including loading & unloading at both ends. 3 safe carriage of line material from store center etah to pit site in distance range 0 to 60 km including loading & unloading at both ends. 4 safe carriage of following t/f form store center, etah je store to different pit site in distance range 0 to 60 km including loading & unloading at both ends. 5 16 kva 6 25/63 kva 7 100 kva 8 250 kva 9 safe carriage of 11 kv vcb from store center etah to pit site in distance range 0 to 60 km including loading & unloading at both ends. 10 erection of 8.5 mtr long pcc pole as single support including fixing of ht/lt accessories etc complete, pole should be grouting/concreting and muffling properly as per dvvnl/respo norms. 11 erection of 11/13 mtr long st pole as single support including fixing of ht/lt accessories etc complete, pole should be grouting/concreting and muffling properly as per dvvnl/respo norms. 12 erection of 8.5 mtr. long pcc poles as d/p or section pole including fixing of ht/lt accessories with tpmo etc. complete, pole should be grouting/concreting and muffling properly as per dvvnl/respo norms. 13 erection of 11/13 mtr. long st poles as d/p/section pole including fixing of ht/lt accessories with tpmo etc. complete, pole should be grouting/concreting and muffling properly as per dvvnl/respo norms. 14 erection of 11/13 mtr. long st poles as tri pole including fixing of ht/lt accessories with tpmo etc. complete, pole should be grouting/concreting and muffling properly as per dvvnl/respo norms. 15 laying sagging, stringing, binding and jumpering etc of following conductor as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t&p, carrier etc required for proper completion of work. 16 dog conductor 17 acsrweasel 18 33 kv xlpe cable 3x300 sq mm 19 11 kv xlpe cable 3x120 sq mm 20 lt pvc cable 3.5x70 sq mm 21 lt pvc armoud cable 2x6 sq mm 22 construction of 250 kva t/f plinth for size 2x2x1.5 m with the help of first class brick and masonary in the ratio 1:4 cement & sand coarse. filling the structure completely as per norms with rcc top 1:2:4 cement, sand coarse and stone grit with ms bar and ms channel for resting transformer wheel (100x50x6mm) and plaster. all material shall be provided by the contractor and installation of 250 kva t/f on it in proper alignment direction & making ht/lt connection all cost of labour and t&p which required for completion of work. 23 net fencing shall be 1150*1200 mm made of 35*35 mm ms angle covered by expended metal 14 swg up to full height 1200 mm duly steftened by ms flat by an 8 swg dia bolt & nut 24 pipe earthingup to water level of 250 kva medium power transformers 25 erection of 11 kv ct/pt pole mounting unit with connection 26 erection of 33 kv ct/pt pole mounting unit with connection 27 installation of 11 kv pilfer metering cubical 28 installation of 33 kv pilfer metering cubical 29 providing and fixing of barbed wire 30 providing and fixing of danger board with clamp/number plate 31 providing and fixing of stone pad 300x300x75 mm 32 erection of stay rod with nozzling etc complete. 33 providing and fixing of double pole/lt clamp 34 providing and fixing of holding clamp 35 providing and fixing of alluminium lug 36 providing and fixing of nut bolts off size 37 fixing of single/three phase disribution box 38 providing and fixing of dead end clamp/piercing connector for ab cable 39 fixing of indoor jointing kit suitable for 11 kv 3x70 sq mm xlpe cable 40 fixing of outdoor jointing kit suitable for 11 kv 3x70 sq mm xlpe cable 41 fixing of intdoor jointing kit suitable for 33 kv 3x300 sq mm xlpe cable 42 fixing of outdoor jointing kit suitable for 33 kv 3x300 sq mm xlpe cable 43 mounting of following transformers at double/single pole of pcc pole supports including connections with lt line etc. complete. 44 10/16 kva 45 25/63 kva 46 100 kva 47 installation of 250 kva t/f 48 earthing of pcc/st pole with ms earth rod as per respo norms/specification. 49 new guarding of ht lines with gi wire as per respo norms/specification.
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Financial Evaluation In Progress
Financial bids are currently under review. Awarded bidder information will be published after final evaluation.