BRR : 10368419
Tender Brief : Purchse Of Medical Stores As Per Rfp , Medicines : , 5.5 Mm Peek Knotless Lateral Row Anchor For Rotator Cuff With Two Components With Proximal Self-Punch In Pointed End; Distal Screw Component Which Locks The Suture Within The Implant And Secure Cortical Fixation Used For Rotator Cuff Repair , A 4.5Mm Tap In Peek Knotless Lateral Row Anchor With Offset Barbed Geometry Threads & Inner Plug Design To Provide More Precise Fixation And Suture Tensioning Of Final Repair , A 5.5Mm Tap In Peek Knotless Lateral Row Anchor With Offset Barbed Geometry Threads & Inner Plug Design To Provide More Precis... Read More
Tender Value
₹
Ref. Document
Submission Date
28-07-2023
Participated Bidder List
5 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | L5 | ||||
| 2 | cnet-technologies | Bid Analytics | L1 | ||||
| 3 | cnet-technologies | Bid Analytics | L3 | ||||
| 4 | cnet-technologies | Bid Analytics | L2 | ||||
| 5 | cnet-technologies | Bid Analytics | L4 |
Work Detail
purchse of medical stores as per rfp , medicines : , 5.5 mm peek knotless lateral row anchor for rotator cuff with two components with proximal self-punch in pointed end; distal screw component which locks the suture within the implant and secure cortical fixation used for rotator cuff repair , a 4.5mm tap in peek knotless lateral row anchor with offset barbed geometry threads & inner plug design to provide more precise fixation and suture tensioning of final repair , a 5.5mm tap in peek knotless lateral row anchor with offset barbed geometry threads & inner plug design to provide more precise fixation and suture tensioning of final repair , arthroscopic shavers 4.5mm compatible with smith and nephew shaver system , all suture anchor of size 1.8mm loaded with #2 magnum wire suture, with radial expansion up to 4mm on deployment for instability , 1.9mm all suture tap in anchor made up of high molecular weight polyethylene braided fiber & pre-loaded with double ultrahigh molecular weight polyethylene braided sutures which opens up to 3mm post deployment with special deployment mechanism through unique visual, tactile & auditory cues intended for instability repair , 1.8 mm all suture anchor double loaded for bankart repair , all suture anchors of size 2.8 mm loaded with #2 magnumwire suture, with radial expansion upto 5.5mm on deployment for rotator cuff repair , continuous loop femoral cortical suspension device having titanium button measuring 20mm, preloaded with lead suture and flipping suture. device should be supported by over 20 years of clinical success , continuous loop femoral cortical suspension device having titanium button measuring 15mm, preloaded with lead suture and flipping suture. device should be supported by over 20 years of clinical success , continuous loop femoral cortical suspension device having titanium button measuring 25mm, preloaded with lead suture and flipping suture. device should be supported by over 20 years of clinical success , bio-compatible fenestrated screw dia 10*30mm (65% plga, calcium sulphate &?-tcp , bio-compatible fenestrated screw dia 11*30mm (65% plga, calcium sulphate &?-tcp , bio-compatible fenestrated screw dia 12*30mm (65%plga, calcium sulphate &?-tcp , bio-compatible fenestrated screw dia 09*30mm (65%plga, calcium sulphate &?-tcp , adjustable femoral cortical suspension device having titanium button and ultrahigh molecular weight polyethylene loop with cradle to protect graft , all inside curved meniscus repair system for repairing meniscus tear, it should have depth limiter, active deployment, pre knotted 2 peek implants with suture, should be able to rotate freely depending upon the tear , all inside reversed curve meniscus repair system for repairing under surface meniscus tear, it should have depth limiter, active deployment, pre knotted 2 peek implants with suture, should be able to rotate freely depending upon the tear , all inside straight meniscus repair system for repairing meniscus tear, it should have depth limiter, active deployment, pre knotted 2 peek implants with suture, should be able to rotate freely depending upon the tear => limited
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Financial Evaluation In Progress
Financial bids are currently under review. Awarded bidder information will be published after final evaluation.
PriceBid
Similar Tenders Results