BRR : 10340651
Tender Brief : Tender for To get the work done under deposit scheme head against various packages under Electricity Distribution Section II, Etawah. - Carriage of PCC pole from Store Center Kunera Etawah to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work. 2 11 Mtrs. long ST pole 3 8.5 Mtrs. long PCC pole 4 Line material i.e. conductor, G.I. wire TPMO stay rod, disc insulator, cross arm, Angle channel, Different type of Clamps and other ... Read More
Tender Value
₹
Ref. Document
Submission Date
07-01-2025
Participated Bidder List
3 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 1,29,955.64 | L1 | |||
| 2 | cnet-technologies | Bid Analytics | 1,32,554.75 | L2 | |||
| 3 | cnet-technologies | Bid Analytics | 1,37,856.95 | L3 |
Work Detail
tender for to get the work done under deposit scheme head against various packages under electricity distribution section ii, etawah. - carriage of pcc pole from store center kunera etawah to site of work through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work. 2 11 mtrs. long st pole 3 8.5 mtrs. long pcc pole 4 line material i.e. conductor, g.i. wire tpmo stay rod, disc insulator, cross arm, angle channel, different type of clamps and other required material 5 acsr weasel conductor 6 33 kv 3 core all. xlpe cable 7 3x50+1x35+1x16 sqmm abc cable 8 3x95+1x70+1x16 sqmm abc cable 9 25 kva transformer 10 erection ofsinglesupportbyst/pcc pole includingfixingcompleteht/lt fittingsasperresspomunualincludingthecostoflabour, t&p and carrier etc. required for proper completion of work. 11 groutingofsinglesupport st/pcc pole asperresspomanual including of the cost of labour,t&p and carrier etc. required for proper completion of work. the support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. 12 erection & grouting ofdouble pole including fixing completeht/ltfittingasperresspomanualincludingthe cost of labour, t&p and carrier etc. required for proper completion of work. the support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. 13 laying, sagging, stringing, binding & jumpering of acsr weasel conductor on the newly erected pole asperrespomanualandasperdirectionofsupervising engineer,includingthecostofarrangementoflabour,t&p carrier etc. required for proper completion of work. 14 laying, sagging, stringing, binding & jumpering of following cable on the newly erected pole asperrespomanualandasperdirectionofsupervising engineer,includingthecostofarrangementoflabour,t&p carrier etc. required for proper completion of work. 15 3x50+1x35+1x16 sqmm abc cable 16 3x95+1x70+1x16 sqmm abc cable 17 laying, sagging, stringing, binding & jumpering of33 kv 3 core all. xlpe cable includingfixingof allaccessoriesasper resspo manual and as per direction ofsupervising engineer, includingthecostofarrangementoflabour,t&pcarrieretc. required for proper completion of work. : 18 erection and grouting of stay set including the work of nozzling etc. as per respo manual and also including the cost of arrangement of allgrouting material, labour, t&p etc. required for proper completion of work as per resspo manual. 19 fixing &connectingofearthingrod complete as as perresspomanual includingthecostoflabour,t&petc.requiredforproper completion of work. 20 fixing ofltdistribution box including making connections of distributionboxwithltmainsbypiercingclampsforarial bunchedcable.theworkwillalsoincludethe openingofthe serviceconnectionoftheconsumeranditsconnectingin distribution box. 21 mounting of 25 kva transformer on the single pole/double pole/plinth structures and connections thereof. 22 guardingof ht/lt 11 kv line with gi wire as per respo norms. includingthe costofarrangementoflabour, t&p etc required for proper completion of work. 23 installation & fixing of following accessories. includingthecostoflabour, t&p and carrier etc. required for proper completion of work. 24 polymer pin insulator 25 11 kv pin insulator with pin 26 polymer disc insulator 45 kn 27 11 kv disc insulator 28 top channel 100x50x5x2240 mm 29 11 kv v type cross arm 30 11 kv cross arm 31 cross arm holding clamp 32 stay wire 33 11 kv fuse set 34 11 kv f clamp for 8.5 pcc pole 35 t/f base angle 65x65x6x2028 mm 36 dp clamp for 8.5 pcc/st pole 37 dropper channel 38 nut & bolt 39 t-off channel 40 11 kv tpmo set 41 i-hook with clamp 42 distribution box 43 distribution box clamp 44 disc fitting 45 suspension clamp 46 lt pearsing connector type 47 pg clamp 48 dead & clamp
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Financial Evaluation In Progress
Financial bids are currently under review. Awarded bidder information will be published after final evaluation.
PriceBid