BRR : 10327715
Click Here To View Tendering Authority. Price Bid City/State :  sikandra, Uttar Pradesh
Tender Brief : Supply 33 Kv Hardware Accessories , Supply Of 33 Kv Ct Clamp With Bimetallic Type Bushing For Ct Rating 2000/1250/1 Amp Suitable For Twin Moose Conductor Complete With All Nut Bolt Washer As Per Sample , Supply Of 33 Kv Ct Clamp With Bi-Metallic Type Bushing For Ct Rating 800/400/1 Amp Suitable For Twin Panther Conductor Complete With All Nut Bolt Washer As Per Sample , Supply Of 33 Kv Ct Clamp With Bimetallic Type Bushing For Ct Rating 400/200/1 Amp Suitable For Twin Panther Conductor Complete With All Nut Bolt, Washer As Per Sample , 33 Kv Isolater Terminal Connector U Bolt With Bimetallic ... Read More
Tender Value
1,99,000
Submission Date
26-05-2025
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 1,74,650 L2
2 cnet-technologies Bid Analytics 2,31,985 L3
3 cnet-technologies Bid Analytics 1,67,132 L1
Work Detail
supply 33 kv hardware accessories , supply of 33 kv ct clamp with bimetallic type bushing for ct rating 2000/1250/1 amp suitable for twin moose conductor complete with all nut bolt washer as per sample , supply of 33 kv ct clamp with bi-metallic type bushing for ct rating 800/400/1 amp suitable for twin panther conductor complete with all nut bolt washer as per sample , supply of 33 kv ct clamp with bimetallic type bushing for ct rating 400/200/1 amp suitable for twin panther conductor complete with all nut bolt, washer as per sample , 33 kv isolater terminal connector u bolt with bimetallic slip type suitable for twin panther conductor made lm 6 alloy thickness of connector from all sides should be less than 12 mm and casting of connector should be free from below holes pad size of connector which is to be matched with isolater plate 80*80 mm 3 no ubolts of size 10mm including nut, spring &flat washer duly galvanized should be provided with connector for proper tightining of conductor connector should be as per sample , 33 kv isolater terminal connector u bolt with bimetallic slip type suitable for twin moose conductor made lm 6 alloy thickness of connector from all sides should be less than 12 mm and casting of connector should be free from below holes pad size of connector which is to be matched with isolater plate 80*80 mm 3 no ubolts of size 10mm including nut, spring &flat washer duly galvanized should be provided with connector for proper tightining of conductor. connector should be as per sample , 33 kv breaker terminal connector u bolt with bimetallic slip type suitable for twin panther conductor made lm 6 alloy thickness of connector from all sides should be less than 12 mm and casting of connector should be free from below holes. pad size of connector which is to be matched with breaker plat 100*100 mm 6 no ubolts of size 10mm including nut, spring & flat washer dul galvanized should be provided with connector for proper tightining of conductor connector should be as per sample , 33 kv breaker terminal connector u bolt with bimetallic slip type suitable fo twin moose conductor made lm 6 alloy thickness of connector from all sides should be less than 12 mm and casting of connector should be free from below holes pad size of connector which is to be matched with breaker pla 100*100 mm 6 no ubolts of size 10mm including nut.spring & flat washer du galvanized should be provided with connector for proper tightining of conductor connector should be as per sample , supply of pg clamp duly made of lm-6aluminium alloy suitable for acsr panther to acsr panther conductor complete with 4 no. 16x90mm gi bolt nuts spring &plain washer as per technical specification and sample , supply of pg clamp duly made of lm-6aluminium alloy suitable for acsr panther to acsr moose conductor complete with 4 no. 16x90 mm gl bolts nuts. spring &plain washer as per technical specification and sample , supply of pg clamp duly made of lm-6aluminium alloy suitable for acsr panther to acsr moose conductor complete with 4 no. 16x90 mm gl bolts nuts. spring &plain washer as per technical specification and sample
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download fc9fd334-3906-4929-b797-6bb0310da0c3 financialevaluation notice
Download boqcomparativechart boq document
Download finance_1879743 aoc document
Download finsummary_1879743 aoc document
Download File Name File Description
Download PART1 Tender Documents
Download Tendernotice_1 Tender Documents
Download 70fac149-c571-4a4c-865e-7663d322ac1b Tender Documents
Download BOQ_1879743 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.

PriceBid
Similar Tenders Results
TenderDetail
Loading tenders