BRR : 10184280
Tender Brief : Repairing Of Pre-Fabricated Bsl Iii Laboratory With 2Yrs Of Cmc And The Cmc May Be Extended Up To 5Yrs ( On Yearly Basis ) , The Repair Of Pre-Fabricated Bsl-Iii Lab , Installation Of New Plc / Bms Control For Bsl 3 Lab Operation & Monitoring , Supply& Installation Ofahu With Pre & Fine Filters , Exhaust Ahu Motor Repair , Supply & Installation Of Supply Terminal Gel Seal Mini Pleat Hepa Filters H13 – 5 No , Supply & Installation Of Exhaust Terminal Gel Seal Mini Pleat Hepa Filters H13–04No , Service & Maintenance Of Double Door Autoclave , Replacement Of Air Cooled Chiller With 11 ... Read More
Tender Value
₹
Ref. Document
Submission Date
11-08-2023
Participated Bidder List
6 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 92,00,000 | L4 | |||
| 2 | cnet-technologies | Bid Analytics | 73,39,350 | L1 | |||
| 3 | cnet-technologies | Bid Analytics | |||||
| 4 | cnet-technologies | Bid Analytics | 82,21,200 | L2 | |||
| 5 | cnet-technologies | Bid Analytics | 90,47,036 | L3 | |||
| 6 | cnet-technologies | Bid Analytics |
Work Detail
repairing of pre-fabricated bsl iii laboratory with 2yrs of cmc and the cmc may be extended up to 5yrs ( on yearly basis ) , the repair of pre-fabricated bsl-iii lab , installation of new plc / bms control for bsl 3 lab operation & monitoring , supply& installation ofahu with pre & fine filters , exhaust ahu motor repair , supply & installation of supply terminal gel seal mini pleat hepa filters h13 – 5 no , supply & installation of exhaust terminal gel seal mini pleat hepa filters h13–04no , service & maintenance of double door autoclave , replacement of air cooled chiller with 11 tr condensing unit. , replacement of ahu water pipes with condensing unit coil , repair of cassette ac 2 ton01 no , repair of 1.5 ton split ac – 03 no , repair of biosafety cabinet b2 type -01 no , replacement / repair of 20 kva ups , supply & installation of 20 kva ups batteries , supply & installation of temp / rh / dp monitor with alarm for the facility – 02 n0 , supply & installation of differential pressure gauges – 06 no , smoke detectors and alarm system: , replacement of faulty ceiling lights , repair of static pass box – 02 no , repair and replacement of cctv cameras- 04camera, dvr and monitor , service / maintenance of dg set , repair & maintenance of decontamination system , repair of refrigerator , repair of -86 deep freezer , air balancing for maintaining negative pressure gradient inside the facility. , execution of cmc , 1st year cmc , 2nd year cmc , 3rd year cmc , 4th year cmc , 5th year cmc
View Original Notice/Document
Result Documents
Tender Documents