View Bid Results For Telephone Plan Tenders

We found 597 Bid Results related to telephone plan tenders. You can find Contractor details who won telephone plan tenders along with contract details in Bid awards announcements section.

Filters
Stage
473
98
26
Tender Publishing Platform
185
412
State / UT
32
106
84
80
46
35
34
30
24
17
15
13
13
12
12
11
9
8
6
5
5
5
5
3
3
3
3
2
2
2
2
1
1
Contract Value
296
130
120
50
Publish Date
0
1
0
0
0
Sector
24
221
98
72
59
32
20
20
13
11
9
7
6
4
4
4
3
3
3
2
2
1
1
1
1
Ownership
4
297
226
44
30
Within keyword
Active filters:
Showing 1–12 of 597 tenders matching your filters
Contract Date: Jun 17, 2026 Contract Value : 3.80 Lakh
Government Departments No of Bidders 1
3.
Housing Urban and Rular Development #11229363 AOC
Misc. Repairs And Other Civil Works Of Tiles, Doors, Windows,Wooden Flooring, Shed And Internal And External Painting In C.M. Bunglow Civil Line Nagpur.(Only For Society).-= 1 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand 2 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 3 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. 4 Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 1190 to 1202 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring 5 Providing and laying Vitrified MATT finishhaving decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical andconfirmingtoIS15622-2006(GroupBla)ofapprovedmakeshadeandpatternfor flooringinrequiredpositionlaidonabedofbondingchemicalfillingjointscuringand cleaning etc .complete. 6 Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. 7 Providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 8 Providing and fixingTable top white wash basin of size 120x635x405mm rubber plugs and brass chain, withpillar cock, C.P.Angular stop cock long thread, continentalincluding S.S. bottle trap of approved make havingnecessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. 9 ProvidingandapplyingTextureplasterwithfinishingwithtexturematerial ofapproved makein 3 to 4 millimeterthickness on previously plastered surface, including Plaster Groove 6mmthicknessorTapeGrooves35to45mmthicknessorasrequired,inallposition including preparing the surface, scaffolding etc. complete. 10 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box 11 Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand. 12 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm 13 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 14 Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etccomplete 15 Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete.b) Granite 16 Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. 17 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. 18 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc.as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.Spec. No. : As directed by Engineer-in-charge. 19 Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors/windows including providing and fixing clips, putty etc. complete. (a) 2.00 mm thick. 20 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. 21 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. 22 Removing W.C. Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the service-able materials as and where directed includingthrowing the unserviceable materials out side etc. complete. 23 Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 24 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. 25 Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. 26 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 27 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 28 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 29 Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 30 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 31 Providing and fixing C.P. BIB cock with wall flange jaquar or equivalent make continental (CAT.NO. CON-047) including necessary sockets/ union nut etc. complete. 32 Providing and fixing C.P. Angular stop clock with wall flange Jaquar make or equivalentcontinental (CAT.NO. CON-059) including necessary sockets/union nut etc. complete. 33 Providing and fixing C.P. pillar cock long neck with aerator jaquar or equivalent make continental (CAT.NO. CON -021) including necessary sockets/union nut etc. complete. 34 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 35 Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 36 Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. 37 Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets & necessary fittings and tested as per municipal requirement etc. complete. 38 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres 39 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 40 Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover. 41 Providing & constructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover etc. complete. 42 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange jaquar or equivalent ?make continental (CAT.NO. CON-273 UPR) including necessary sockets/union nut etc. complete. 43 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 44 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. 45 Providing and fixing crimped with G.I. mesh and size 20 mm x 20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel) 46 Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. 5 km leadloading unloading 47 Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. 48 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 kg) 49 Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 kg) 50 Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kg/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaningetc. complete. (using 100% crushed sand) 51 Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards,screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. 52 Providing and fixing Shutter to wall Cupboard consisting of Teak Wood styles and Rails 25 mm thick and 75 mm wide with panel insert of 12 mm thick particle Board with one approved coloured Laminated Face on one side 1.5 mm thick, bonded with Phenol Formaldehyde Synthetic Resin including Lipping Beading. Iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame). 53 Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 90 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete.(excluding painting to underside of plank). 54 Providing and fixing C.P. 2 Way BIB cock with wall flange of approvedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge. 55 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) 56 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete 57 Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. 58 Trimming of grass, shurbs and weeds from the shoulders/berms and disposing off the same to suitable locations etc. complete 59 Replacement of damaged Mortise Lock of approved quality and make to door shutter including Removing and Refixing with Necessaryscrew, making proper adjustment for smoothoperation etc. complete as per sample approved by Engineer in-chareg. 60 ProvidingHydrulic door closer .... 61 ProvidingSuper Jet Spry with flange 2 in 1 faucet 1.50 mtr long. 62 Providing Skilled plumber with tools as per direction of Engineer Incharge. 63 Providing skilled carpentor with tools as per direction of Engineer Incharge 64 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface and including scraping etc. complete. 65 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 66 Providing and applying single coats ofexterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. 67 Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete 68 Providing and fixing high level 10 liter capacity with fittings inlet PVC pipe with stop tap ,brackets for fixing the cistern,32 mm dia. PVC flush pipe with fitting and clamps 20 mm dia. PVC overflow pipe with mosquito proof couplings, galvanised iron chain and pulley painting if ordered to cistern pipe etc. and cutting and making good the damaged wall and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) 69 Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. 70 Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete 71 Providing curtain rod dropping with channel MAC brand of superiar quaility including all required material labour etc complete. as directed by engineer incharge......... 72 Replacement of damaged alluminium Butt Hinges of 125 mm of approved quality and maketo door shutter including removing existing the same inoriginal position making prope radjustment for smooth operation etc. complete as per sample approved by Engineer incharge. 73 Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and maketo door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. 74 Replacement of damaged Tower Bolt 300 mm Chromium plated of approved quality and maketo door/window shutter including removing existing the same inoriginal position making proper adjustment for smooth operationetc.complete as per sample approved by Engineer in-charge. 75 ProvidingHandle 150 mm Chromium plated (Rounded shape). 76 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. 77 Providing and injecting epoxy grout including structuring of crack in the body of slab girder by sand blasting, fixing inlet tube arrangement including cost of materials, machinery required for the work and labour charges etc. complete. 78 Providing & fixing Decorative wall paper superior quality including adhesive to fix at wall etc complete. as directed by engineer incharge......... 79 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 80 Providing & fixing Mica laminate as per ISI 0.1 mm thick etc complete...... 81 Providing & fixing 19 mm plywood 710 bwp full red core with report etc complete...... 82 Providing & fixing 12 mm plywood 710 bwp full red core with report etc complete...... 83 Providing & fixing teak wood batterns 50x25 mm etc complete...... 84 Providing & fixing plain glass 6 mmetc complete...... 85 Providing & fixing teak wood batterns 70x45 mm etc complete...... 86 Providing & fixing door stopper etc complete...... 87 Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete. 88 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 89 Providing and Laying wearing laminate wooden or eqiuvalent flooring 8 mm thick in attractive strips for conference hall. 90 Providing, laying andfixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 kg/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 91 Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. 92 Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with allnecessaryfixturesandfittingetc.complete.(SampletobefinalbyEngineerIn-charge prior execution of work) 93 Providing and applying French polish for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding etc. complete as directed 94 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. 95 Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 96 Providing and fixing C.P. sink cock with raised J shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete. 97 Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. 98 Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. 99 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 100 BASIC TEST OF CEMENT :-Standerd Consistancy Fineness, Specific Graviti, Setting Time (Initial & final, Compressive Strength, Soundness. 101 BASIC TEST OF BRICK :-Water Absorption, (Set of 5 Brick), Comoressive Strength (Set of 5 Blocks), Efflorescence (Set of 5 Bricks) 102 CERAMIC TILES/ VITRIFIED TILES :- Water Absorption, Modules of Rapture (Set of 6 Tiles) 103 BASIC TEST OF C. C. TILES. :-Flexural test(Set of 6 tiles) Water Absorption,(Set of 6 tiles) Resistance to wear(Set of 6 tiles). 104 BASIC TEST OF Fine Aggregate Fineness Modulus (Sieve Analysis) silt and cley content..... 105 BASIC TEST OF Concrete Paving Block :- Compressive strength, Water Absorption, (Set of 8 Blocks ) 106 BASIC TEST OF STONE / RUBBLE/ Crushing Value/Compressive strengh, Water 107 Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction materials for whichroyalty is necessary.(Royalty charges will be paid to contractor after sumbitting valid documents of revenue authority)Royalty for naturalSand (Royalty + Surcharges 2% & Distt. mineral foundation cess 10%)
Contract Date: Jun 04, 2026 Contract Value : 15.18 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
Contract Date: Jun 02, 2026 Contract Value : 5.92 Lakh
Government Departments No of Bidders 1
6.
Public Administrative Department #11142241 AOC
Construction And Carry Out Ancillary Works For Urban Ayushman Health Temples (Uhwc) In Porta Cabins At 14 Places In The Jurisdiction Of Thane Municipal Corporation.-1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. :Means Bd.A.1 Page No.259 2 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means 3 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. 4 Transportation of excavated material including loading and unloading etc. complete. (c) lead up to 5 km) 5 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. 6 Providing soling using 80 mm size trap metal in 15 cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. 7 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 8 Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 9 Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use).Spec. No As director by engineer incharge. Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec. No As director by engineer incharge. Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. 14 Painting letters upto 20 centimetre height including cost of brushes, coir brushes dusting, cleaning etcetera complete. Spec. No. As Directed By Engineer In Charge. Only For Road Side Furniture. Spec .No. MORTH 801 15 Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. 16 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. cover of 75 Kilogram with lid and frame fixed in cement concrete.. Spec. No. 17 Providing and laying in trenches 25 mm dai. UPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 18 Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying) 19 Providing and making ISI Mark ferrule connection of 25mm dia.to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. 20 Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters 21 Supplying, erecting, testing and commissioning of minimum three and above star rated centrifugal water pump (monoblock),230 V,single phase,50 Hz,AC.supply of 0.375kw/0.5 HP with discharge 36/9 lpm for head of 6/21 m & 25 mm suction /25 mm delivery pipe on provided CC foundation as per specification no.WP.CGP. 22 Supplying, installing and testing earthing with copper earth plate 30 x 30 x 0.315 cm complete with all accessories of copper materials and recording the results as per specification no.Ea-EP Supplying, & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 Kg.capacity cartridge type conform to IS 2878/15683 complete erected with necessary clamp made from 50 x 6 mm M.S. flat with nut & bolts rounded in wall complete. Supplying, & erecting Hand dryer machine having speed jet of warm air with low noise blower to quick dry wet hands,power 1800 W,voltage 230V,50 Hz.Automatic cut off after 5-10 second. Providing,Supplying and fixing electrical meter with all necessary accessories,required cable for connection from main supply including required permission from MSEDCL,TORRENT and Local authorities.(The contractor shall submit the original receipts of payments made to MSEDCL, Torrent Power co.The payments will be made as per the actual expenses made by contractor for each permission and purchasing of electric meter.) Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying and laying (including excavation) 50 mm outside dia double wall corrugated pipe (DWC) of HDPE for enclosing cable below ground/road surface to required depth completed Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Providing, Supplying and installation of Porta Cabin Fabricated at Factory Scope of work per cabin shall includes as follows 1. Specification mentioned as below 2. Internal and external arrangement of cabin as per drawings as attached 3. Works of Plumbing, sanitary, electrification, CCTV 4. Furniture as below a. Executive Chairs (as per sr.no.3) - 3 nos, b. Visitor chair (as per sr.no.4) - 6 no c. Two seater chair (as per sr.no.5) – 2 Nos d. Three seater chair (as per sr.no.6) – 5 Nos e. Patient Examination Couch/Table (as per sr.no.8) – 2 Nos f. Storage Cabinet (as per sr.no.9) – 1 Nos g. Table (as per sr.no.10) – 4 Nos h. Table (as per sr.no.11) – 1 Nos i. Medical Store Racks in pharmacy room (as per sr.no.12) – as per drawing j. Trash Bin (as per sr.no.13) – 6 Nos k. Seating tools (as per sr.no.7) – 6 Nos Detailed Description and Specification: Unit Size – L x B x Ht = 30 ft x 20 ft x 9 ft (Clear internal Height) Cabin should be structurally stable and suitable to meet severity of climatic conditions. Sustainable in wind condition of 55m/s- in Seismic zone IV and ambient temperature range (-) 40 degree C to (+) 50 degree C. Bottom Frame 80 x 40 x 2mm GI Rectangular Hollow Pipe (Apollo Make) Stiffener Bottom 50 x 50 x 2mm GI Rectangular Hollow Pipe (Apollo Make) for Shorter Span and 80 x 40 x 2mm for longer Span making the grid of 2ft x 2ft. Please note Base frame shall be quoted with special type of anticorrosive paint to avoid rusting and for better life (i.e. Black Coal Tar Epoxy Paint) Top Frame 80 x 40 x 2 mm GI Rectangular Hollow Pipe (Apollo Make) Stiffener (Top Frame) 50 x 50 x 2mm GI Rectangular Hollow Pipe (Apollo Make) for Shorter Span and 80 x 40 x 2mm for longer Span making the grid of 2ft x 2ft. Please note Base frame shall be quoted with special type of anticorrosive paint to avoid rusting and for better life (i.e. Black Coal Tar Epoxy Paint) Paneling Outside Outside Wall of the cabin shall be made from 16 guage GI sheet with solid color of approved shade, fitted on inside GI pipe framing making the grid of 2ft x 2ft. Paneling Inside Inside wall of the cabin shall be made from 3 MM Thk ACP sheet with aluminum foil thickness of 0.25 mm with solid color of approved shade fitted on inside Gl pipe framing making the grid of 2ft x 2ft. All the ACP joints shall be filled with Black silicon. Wall Panels shall be completely insulated with Glass wool of 48 kg/m3 Density and slab thickness 50mm. Corners Pole 72 x 72 x 3.2mm GI Rectangular Hollow Pipe (Apollo Make) with black coal tar epoxy coating Plumbing Arrangement UPVC concealed internal plumbing system shall be provided with all necessary inlet and outlet points as per the Drawing. External water connection shall be Provided by TMC. Drinking Arrangement Providing and Fixing branded water purifier of make like Aquaguard, Kent, LG or equivalent with all necessary connections, fittings accessories with storage arrangement etc. complete Sanitary Fittings All plumbing and sanitary fittings such as Ceramic Western Commode with seat cover, Ceramic Indian Commode, Ceramic urinal with push pillar cock, Ceramic Wash Basin, Wash basin Push Pillar Cock shall be of brand like Kajaria, Hindware, Paryware or equivalent. All western Toilets must be equipped with jet Spray, 2 in 1 Taps and Flush Tank. Accessories for PWD persons shall be provided in all toilets. (Excluding External Sewerage Connection). Roof Outside Roof Slope 1:2 one way 126 Roof shall be made from 1.2 mm 120 GSM GI sheets of Jindal make, which shall be fully welded and sloped to avoid leakage. All the roof joints shall be covered with 75mm Butyl Vinyl Tape. Roof shall be covered with Heat Resistant paint to maintain low temperature inside the cabin. Roof Gutter Specially designed gutter section shall be provided to drain water at the single side of the cabin. This shall be made from 1.2 mm 120 GSM GI sheet Jindal make including fitting arrangement. False Ceiling False Ceiling shall be made from 3 mm Thk ACP sheet with Aluminium foil thickness of 0.25 mm with solid colour of approved shade fitted on inside GI pipe framing making the grid of 2ft x 2ft. All the ACP joints shall be filled with Black silicon. Flooring Flooring shall be made from 18 mm High Strength Bison board/ Cement fibre sheet, which is covered with 2 mm PVC vinyl flooring for cabin. For toilet Cement sheet shall be covered by 10 mm thick 1 X 2 ceramic tiles which shall be fixed by using tile adhesive and cement mixture of at least 50mm Thk. Doors & Door frame Main Door Flush door 32 mm thick waterproof material with 4mm Glass as per approved design and drawing and door frame shall be made from aluminium Section. Locking arrangement along with D Handles in SS 304, door closer, door stopper etc. Door Size: 5’x 6’ Internal doors shall be sliding doors/ flush door of size as per drawing and as per the specifications decided by engineer-in charge Toilet Door and door frame shall be made from aluminium frame with 4mm Glass and ACP including locking arrangement, Handles in SS 304, Door Size: 2’-6’’ x6’ Windows Powder coated aluminium Two Track sliding windows with 4 mm tinted Glass. Size of windows as per drawings. M.S. Grill of weight @ 20 kg per sqm shall be provided to all windows/louvered window from outside. Curtains of good quality and curtain rod/track with fixtures shall be provided from inside of windows. Insulation False Ceiling and Wall Panels shall be completely insulated with Glass wool of 48 31 Providing, Supplying and installation of Porta Cabin Fabricated at Site Scope of work per cabin shall includes as follows 32 Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 Kilogram/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm, skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 33 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 34 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 35 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 36 Testing :- Compressive test of C.C.Cube 37 Provide and supplying Executive Chairs A generously cushioned, molded PU seat combined with breathable mesh fabric, Crafted from strong and durable Polyamide (Nylon) featuring a reinforced mesh back, chair equipped with BIFMA Certified Class-4 Hydraulic Gas Spring and BIFMA Certified 60mm Wheel Castors. Chair having 3 years warranty (Executive chairs) / or equivalent / as Directed by Engineer Incharge. Key Features Colour : GREY / Black Material : Metal Dimensions : 64D x 61W x 119H Centimeters Size : Standard Back Style : Mesh Back Special Feature : Adjustable Lumbar, Adjustable Height, Adjustable Arm Rest, Adjustable Head Support Seat Material Type : Breathable Microfiber Cloth Covered in PU Foam 38 Providing and supplying visitor chair having size Depth- 62cm, width-55cm, height- 80cm & seat height 45 cm. (+/- 2cm ), having seat & back, shall be made up of 1.2 cm hot pressed plywood, approved tapestry upto Rs.300/m and mould polyurethane foam with P.V.C. lipping all around etc. complete. The chair shall be provided with two one piece armrest made of polypropylene. The chair shall be supported by cantilever type powder coated tubular frame dia 2.54cm x 14 B G M.S.E.R.W. tube. All aluminium steel component shall have Epoxy Polyster Powder Coated. The chair shall be Ergonimc Dry film thickness shall be more than 45 Micron. And as directed by Architect in charge. The over all appearance of the product shall be as per photograph. All metal work shall be Epoxy Polyster Powder Coated and as directed by Architect in 39 Public Seating Chair. - 2 Seater Providing and Fixing 2 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish with 1 year warranty etc complete as directed by engineer in charge.. 40 Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 41 Seating tool for Lab and Class-IV Providing and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge. 42 Providing and supplying examination couch. This examination couch features an adjustable backrest that can be easily operated using a gas spring system. The twosection foam-padded top provides added comfort for patients during examinations. It is equipped with three drawers and three cabinets, offering ample storage space for medical equipment and supplies, keeping everything organized and easily accessible. A tray for the B.P. apparatus is conveniently placed near the headrest, ensuring easy access for medical professionals. The couch is finished with pre-treated epoxy powder coating, making it durable and easy to clean, while also ensuring resistance to corrosion Designed with a carrying capacity of 150-180 kg. etc complete. as directed by engineer in charge. Key Features Adjustable Backrest: The backrest is adjustable using a gas spring system, providing flexibility for various examination positions. Foam Padded, Upholstered Top: Offers comfort and support during patient examinations. Ample Storage: Equipped with three drawers and three cabinets to store medical supplies and equipment. BP Tray: A tray near the headrest for easy access to BP apparatus. 43 Providing, supplying and installing the cabinet, dimensions of 1200mm (W) x 1660mm (H) x 450mm (D) and is constructed from prime quality 0.8mm thick CRCA steel for the body panels and shelves. The shelves are adjustable in height and have a uniformly distributed load capacity of 50kg per shelf. The vertical sides feature continuous slots for mounting shelves at variable heights. The entire carcass is finished with a 50 ±10 microns epoxy polyester powder coating. The facia of the cabinet consists of metal shutters with metal borders, incorporating toughened glass panels. The handles are Dshaped in an aesthetically pleasing design with a stainless steel (SS) finish. The locking mechanism uses a metal cam lock for security. Additionally, the cabinet is equipped with adjustable levelers featuring plastic bases, allowing height adjustments of up to 15mm.This furniture is built according to the specifications and samples approved by the client. It meets the required certifications including ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, BIS standards, and is a BIFMA Gold certified member. The product comes with a 5-year warranty. Installation and other details are as directed by the engineer in charge. 44 Providing & Fixing of HNI Make table of Size. The Worktop shall be made of 25mm Prelam particle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. The above furniture should be as per specification with 3 years warranty etc. sample approved by client. TABLE SIZE :- W1060mm x D600mm x H750 mm -1 No W900mm x D300mm x H750 mm – 1 No W600mm x D450mm x H750 mm – 2 No As Directed by Engineer Incharge 45 Providing & Fixing of HNI Make table of Size. The Worktop shall be made of 25mm Prelam particle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. Legs are made of powdered coated steel 50mmx 50mm Section. Cross Member are in CRCA steel and the Beam is made of MS of 1.5mm thickness in powder coated finish of 50 microns thickness. The above furniture should be as per specification with 3 years warranty etc. sample approved by client. TABLE SIZE :- W1200xD700xH740mm As Directed by Engineer Incharge 46 Providing and supplying adjustable MS storage rack having size 1200 mm to 1800mm x 300 mm x 1600 mm including all transportation upto site etc complete as directed by engineer in charge. Key features 1. Material  Frame : Mild steel (MS) powder coated  Shelves: Cold-rolled steel (CRCA) or galvanized  iron (GI) 2. Angle Specifications  Size 40 x 40 x 2.50 mm  Length : Standard lengths of 6 feet, 8 feet, or 10 47 Providing and supplying trash bins with a maximum height of 450mm 35 - 40 liter, made of high-quality molded plastic for durability and ease of maintenance. The bins shall be equipped with a functional lid mechanism and shall be provided as per the approved selection and design. The work shall be carried out as directed by the Engineer-In-Charge etc complete . 48 Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. 49 Providing and Laying M60 grade cement concrete of approved mix design with avg. Flextural strength of 4.4 MPa in 3 days from R.M.C. plant incld. use of micro silica/alcofine, approved make super plastiser and retarder, fibriliated 100 % virgin polypropylene fibres, fly ash and transported by transit mixer and placing at work site. Compacting, finishing, initial curing by approved curing compound/contractors water and tarring the sides of slab with hot bitumen as specified and as directed (w/c ratio 0.28 max.). (vatta for curing will be paid separately) for Ultra thin White Topping (UTWT) pavement. etc completed. Providing second class Burnt Brick masonry with conventional/I.S .type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete Providing structural steel work in single stanchions composed of R.S.J. Channel etc. with caps, bases, mild steel plated, angle brackets, cleats, gusset plates, anchor bolts etc. as per detailed designs and drawings or as directed including cutting, fabrication, hoisting, erecting fixing in position, making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it two. coats of oil painting approved quality and shade etc. complete. Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meter made out of 4 mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity microprismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorized distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminum-Zinc alloy (55% aluminum 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) Providing Excavator (JCB JS 80 or equivalent) of 0.9 Cum etc complete Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec. One Number: As directed by Engineer- in-charge. Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing and laying Cast in situ/Ready Mix cement concrete M-15 trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing tuck pointing with cement mortar 1:3 for stone/Brick masonry including scaffolding and curing etc. complete. Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. Transportation of excavated material including loading and unloading etc. complete. ( (c) lead up to 5 km) Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing soling using 80 mm size trap metal in 15 cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer in charge. Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineerin- charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use).Spec. No As director by engineer in charge. Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec. No As director by engineer incharge. Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Painting letters upto 20 centimetre height including cost of brushes, coir brushes dusting, cleaning etcetera complete. Spec. No. As Directed By Engineer In Charge. Only For Road Side Furniture. Spec .No. MORTH 801 Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. etc
Contract Date: May 21, 2026 Contract Value : 4.09 Crore
Local Bodies No of Bidders 2
Maharashtra View Result →
7.
Public Administrative Department #11109429 AOC
Tender For Master Plan Kalagram At P.L. Deshpande Udyan To Carry Out Various Development Works Remaining work -ITEM NO : 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m.) By Manual Means ( SSR Item No : 21.01 ) (PMC Bhavan ) Unique No (15201) Rate List Year (2024-2025) ITEM NO : 2 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. ( SSR Item No : 46.09 ) (PMC Bhavan ) Unique No (16016) Rate List Year (2024-2025) ITEM NO : 3 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. ( SSR Item No : 46.12 ) (PMC Bhavan ) Unique No (16019) Rate List Year (2024-2025) ITEM NO : 4 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. ( SSR Item No : 46.13 ) (PMC Bhavan ) Unique No (16020) Rate List Year (2024-2025) ITEM NO : 5 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete ( SSR Item No : 46.19 ) (PMC Bhavan ) Unique No (16026) Rate List Year (2024-2025) ITEM NO : 6 Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. SSR Item No : 46.14 ) (PMC Bhavan ) Unique No (16021) Rate List Year (2024-2025) ITEM NO : 7 Transportation of material obtained from excavation including soil, Cu.M rubble, bricks, RCC concrete, kerb stones, steel railing, iron pipes, channels etc. Obtained from excavation, dismantling, loading in a Truck of minimum 5 Cu M capacity or designed capacity and transporting within the municipal limits or any designated place, unloading, stacking or spreading of material etc. complete. As directed by Engineer In charge SSR Item No : 78.36 ) (PMC Bhavan ) Unique No (17223) Rate List Year (2024-2025) ITEM NO : 8 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. SSR Item No : 21.36 ) (PMC Bhavan ) Unique No (15231) Rate List Year (2024-2025) ITEM NO : 9 Providing leather finished polishing to Kota / Marble / Shahabad Kadappa Stone slab by continuous grinding in 4 coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. SSR Item No : 33.57 ) (PMC Bhavan ) Unique No (15525) Rate List Year (2024-2025) ITEM NO : 10 Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. SSR Item No : 21.38 ) (PMC Bhavan ) Unique No (15233) Rate List Year (2024-2025) ITEM NO : 11 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( SSR Item No : 24.04 ) (PMC Bhavan ) Unique No (15309) Rate List Year (2024-2025) ITEM NO : 12 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( SSR Item No : 25.50 ) (PMC Bhavan ) Unique No (15327) Rate List Year (2024-2025) ITEM NO : 13 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( SSR Item No : 25.31 ) (PMC Bhavan ) Unique No (15322) Rate List Year (2024-2025) ITEM NO : 14 Providing first class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth including bailing out water manually, striking joints on unexposed faces, pointing with cement mortar 1:3 on exposed face and watering etc. Complete. ( SSR Item No : 27.02 ) (PMC Bhavan ) Unique No (15371) Rate List Year (2024-2025) ITEM NO : 15 Providing uncoursed rubble masonry of trap / granite / quartzite gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. SSR Item No : 28.01 ) (PMC Bhavan ) Unique No (15385) Rate List Year (2024-2025) ITEM NO : 16 Providing flush grooved pointing with cement mortar 1:3 for stone masonry work including scaffolding and curing etc. complete. SSR Item No : 32.17 ) (PMC Bhavan ) Unique No (15449) Rate List Year (2024-2025) ITEM NO : 17 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound 1Kilogramper cement bag curing the same for not less than days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1: finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. SSR Item No : 32.11 ) (PMC Bhavan ) Unique No (15444) Rate List Year (2024-2025) ITEM NO : 18 Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. SSR Item No : 23.02 ) (PMC Bhavan ) Unique No (15298) Rate List Year (2024-2025) ITEM NO : 19 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Number : As directed by Engineer-in-charge. SSR Item No : 23.07 ) (PMC Bhavan ) Unique No (15303) Rate List Year (2024-2025) ITEM NO : 20 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. ( SSR Item No : 26.33 ) (PMC Bhavan ) Unique No (15352) Rate List Year (2024-2025) ITEM NO : 21 Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete. ( SSR Item No : 42.37 ) (PMC Bhavan ) Unique No (15889) Rate List Year (2024-2025) ITEM NO : 22 Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super Pillar tap with flange including all accessories etc complete ( SSR Item No : 43.41 ) (PMC Bhavan ) Unique No (15981) Rate List Year (2024-2025) ITEM NO : 23 Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super bib tap with flange including all accessories etc complete ( SSR Item No : 43.35 ) (PMC Bhavan ) Unique No (15975) Rate List Year (2024-2025) ITEM NO : 24 Providing and fixing on walls/ ceiling/ floors, 15 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings. remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. ( SSR Item No : 41.10 ) (PMC Bhavan ) Unique No (15792) Rate List Year (2024-2025) ITEM NO : 25 Providing and fixing on walls/ ceiling/ floors 20 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 1.93 Kilogram/meter with necessary fitting remaking good the demolished portion and applying primer of anti-corrosive oil paint, 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. ( SSR Item No : 41.11 ) (PMC Bhavan ) Unique No (15793) Rate List Year (2024-2025) ITEM NO : 26 Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SSR Item No : 41.12 ) (PMC Bhavan ) Unique No (15794) Rate List Year (2024-2025) ITEM NO : 27 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SSR Item No : 42.55 ) (PMC Bhavan ) Unique No (15907) Rate List Year (2024-2025) ITEM NO : 28 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SSR Item No : 42.56 ) (PMC Bhavan ) Unique No (15908) Rate List Year (2024-2025) ITEM NO : 29 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SSR Item No : 42.57 ) (PMC Bhavan ) Unique No (15909) Rate List Year (2024-2025) ITEM NO : 30 Building (Bd-V : Water supply and sanitory fittings)P.V.C. flexible Waste Pipe 32 mm dia SSR Item No : 49.V-74 ) (PMC Bhavan ) Unique No (17745) Rate List Year (2024-2025) ITEM NO : 31 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. SSR Item No : 33.34 ) (PMC Bhavan ) Unique No (15502) Rate List Year (2024-2025) ITEM NO : 32 Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab of approved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. a) One side polish ( SSR Item No : 33.32 ) (PMC Bhavan ) Unique No (15500) Rate List Year (2024-2025) ITEM NO : 33 Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover 75Kilogramwith lid and frame fixed in cement concrete. ( SSR Item No : 42.11 ) (PMC Bhavan ) Unique No (15863) Rate List Year (2024-2025) ITEM NO : 34 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75 Kilogram with lid and frame fixed in cement concrete. ( SSR Item No : 42.10 ) (PMC Bhavan ) Unique No (15862) Rate List Year (2024-2025) ITEM NO : 35 Providing and erecting chain link fencing 1.6 M. height with G. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/ with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete. ( SSR Item No : 46.39 ) (PMC Bhavan ) Unique No (16044) Rate List Year (2024-2025) ITEM NO : 36 Building (Bd-W : Water supply and sanitory fittings)Concentina Coil Wire ( SSR Item No : 49.W-09 ) (PMC Bhavan ) Unique No (18065) Rate List Year (2024-2025) ITEM NO : 37 Building (Bd-V : Water supply and sanitory fittings)Plastic Bucket ( SSR Item No : 49.V-101 ) (PMC Bhavan ) Unique No (17772) Rate List Year (2024-2025) ITEM NO : 38 Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. ( SSR Item No : 41.63 ) (PMC Bhavan ) Unique No (15838) Rate List Year (2024-2025) ITEM NO : 39 Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. ( SSR Item No : 42.30 ) (PMC Bhavan ) Unique No (15882) Rate List Year (2024-2025) ITEM NO : 40 Flat back urinal-providing and fixing flat back urinal without flushing tank but including bracket for fixing urinals,inlet pipe,32mm dia pvc flush pipe and stop tap ,filling the gaps with white cement etc complete ( SSR Item No : 61.04 ) (PMC Bhavan ) Unique No (16484) Rate List Year (2024-2025) ITEM NO : 41 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. ( SSR Item No : 42.20 ) (PMC Bhavan ) Unique No (15872) Rate List Year (2024-2025) ITEM NO : 42 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. ( SSR Item No : 42.67 ) (PMC Bhavan ) Unique No (15919) Rate List Year (2024-2025) ITEM NO : 43 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. ( SSR Item No : 39.9 ) (PMC Bhavan ) Unique No (15683) Rate List Year (2024-2025) ITEM NO : 44 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters SSR Item No : 42.53 ) (PMC Bhavan ) Unique No (15905) Rate List Year (2024-2025) ITEM NO : 45 Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. SSR Item No : 33.25 ) (PMC Bhavan ) Unique No (15493) Rate List Year (2024-2025) ITEM NO : 46 Providing and laying Vitrified mirror/glossy finish having decorative type of size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc . complete. SSR Item No : 33.58 ) (PMC Bhavan ) Unique No (15526) Rate List Year (2024-2025) ITEM NO : 47 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track sect ion 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. SSR Item No : 39.37 ) (PMC Bhavan ) Unique No (15711) Rate List Year (2024-2025) ITEM NO : 48 Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. ( SSR Item No : 36.03 ) (PMC Bhavan ) Unique No (15579) Rate List Year (2024-2025) ITEM NO : 49 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item Number 15 18 prior approval of Superintending Engineer will be necessary ( SSR Item No : 35.26 ) (PMC Bhavan ) Unique No (15576) Rate List Year (2024-2025) ITEM NO : 50 Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. ( SSR Item No : 35.09 ) (PMC Bhavan ) Unique No (15560) Rate List Year (2024-2025) ITEM NO : 51 Providing and applying French polish for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding etc. complete as directed ( SSR Item No : 34.05 ) (PMC Bhavan ) Unique No (15545) Rate List Year (2024-2025) ITEM NO : 52 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. ( SSR Item No : 34.09 ) (PMC Bhavan ) Unique No (15549) Rate List Year (2024-2025) ITEM NO : 53 Providing & fixing WOODEN FINISH/STONE Finish CEMENT PLASTER having Cement Mortar of 1:3 proportion with thickness 20 to 40 mm for wall, columns & beams, slab bottom/top or any surface. Rate includes Cement plaster of proportion 1:4 of wooden effect, after required curing, proper cleaning of surface by sand paper application of 1 coat of Apex exterior grade primer above that 2 coat of exterior grade Apex Paint as a base coat & 1 coat of Apex Paint for making wooden finish/grains & with 2 final coat of Apex clear polish including cement, Sand, chemical, adhesive, chikenmesh, paint, polish, paper, etc. all material, labor, scaffolding, etc. all complete. Work done should be as per a approved sample & the instructions of engineer incharge. SSR Item No : 1 ) (PMC Garden ) Unique No (19717) Rate List Year (2024-2025) ITEM NO : 54 PAINTING OF EXISTING WOODEN FINISH TEXTURED SURFACE at all heights including scaffolding etc. complete. Rate includes proper cleaning of surface by sand paper application of 1 coat of Apex exterior grade primer above that 2 coat of exterior grade Apex Paint as a base coat & 1 coat of Apex Paint for making wooden finish/grains & with 2 final coat of Apex clear polish including cement, Sand, chemical, adhesive, chikenmesh, primer, paint, polish, paper, etc. all material, labor, scaffolding, etc. all complete. Work done should be as per a approved sample & the instructions of engineer incharge. SSR Item No : 4 ) (PMC Garden ) Unique No (19720) Rate List Year (2024-2025) ITEM NO : 55 Providing & fixing BAMBOO FINISH RAILING IN CEMENT MORTOR of 1:3 proportion with appropriate thickness resembling bamboo of diameter 2½ to 3 inch. Railing clear Height 1.0m with underground support of minimum 0.45m depth of 1:1.5:3 ratio concrete of size 0.3 x 0.3 x 0.6m. vertical supports should be at min. 1.0 m intervals & with 10mm Tor steel 2nos in each horizontal member & 3nos in each vertical member. Railing will have two horizontal & two diagonal members in each panel. All external surfaces will have bamboo finish. Rate includes proper cleaning of surface by sand paper application of 1 coat of Apex exterior grade primer above that 2 coat of exterior grade Apex Paint as a base coat & 1 coat of Apex Paint for making wooden finish/grains & with 2 final coat of Apex clear polish including cement, Sand, chemical, adhesive, chikenmesh, primer, paint, polish, paper, etc. all material, labor, scaffolding, etc. all complete. Work done should be as per a approved sample & the instructions of engineer incharge. SSR Item No : 14 ) (PMC Garden ) Unique No (19730) Rate List Year (2024-2025) ITEM NO : 56 PROVIDING and laying Natural River Sand in Play Area or required locations in Gardens, as per the instructions given by the Engineer Incharge, inclusive of material, Labour, Transportation, , etc all complete. ( SSR Item No : 10 ) (PMC Garden ) Unique No (19726) Rate List Year (2024-2025) ITEM NO : 57 Providing and applying a base coat comprising of 1KilogramPolydee-MC and 1Kilogramfresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. ( SSR Item No : 31.11 ) (PMC Bhavan ) Unique No (15428) Rate List Year (2024-2025) ITEM NO : 58 Providing and laying polished hand cut Kotah Stone flooring 25mm to 30mm thick and 45cm to 55cm wide in plain/diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete. ( SSR Item No : 33.08 ) (PMC Bhavan ) Unique No (15476) Rate List Year (2024-2025) ITEM NO : 59 Providing Grouring by specially prepared grout of approved make Sq.m chemical with cement in proportion 135 (1 part chemical & 3.5 part cement by weight) along wih 50 ml super plasticizer non cracking antrwash high strength polymer cement grout PC grout available in bags or equivalent with proper water for injectable consistency and applying it in the body of structure like slab, beam, column, pillars, deckslab, retaining wall, basement, underground and elevated water storage reservoir concrete and brick wall, crack portion of structure etc. by injectng method, to achieve its original strength including drilling of suitable diameter drills holes at 2 to 4 Nos. per sqm. using caps and nozzle grouting machinery necessary, scaffolding, finishing and covering gurantee of 10 years on court stamp paper of Rs. 100/-and necessary testing etc. complete (Prior permission of S.E. in writing is necessary before inclusion of this item in estimate) ( SSR Item No : 52.28 ) (PMC Bhavan ) Unique No (16301) Rate List Year (2024-2025) ITEM NO : 60 Providing and laying yellow jaisalmare 25mm to 30mm thick and required width wide in plain/diamond pattern ona bed of 1:6 C.M. including cement float, filling joints, with neat cement slurry, curing, polishing and cleaning etc.complete. ( SSR Item No : 60.13 ) (PMC Bhavan ) Unique No (16474) Rate List Year (2024-2025) ITEM NO : 61 Building (Bd-V : Water supply and sanitory fittings)Brass nozzle pillar tap 12mm ( SSR Item No : 49.V-146 ) (PMC Bhavan ) Unique No (17817) Rate List Year (2024-2025)
Contract Date: May 19, 2026 Contract Value : 27.25 Lakh
Local Bodies No of Bidders 7
Maharashtra View Result →
8.
Road Transport and Highways #11021845 Technical Bid
Tender For Consultancy Services for Authority’s Engineer for supervision of “Construction and Upgradation of existing road on NH-510 between Rabangla to Gyalshing to 2-lane with paved shoulder configuration in the State of Sikkim under SARDPNE Phase ‘A’ on EPC mode for (i) Design Chainage Km 32+500 to Km 33+600 (PackageIII), (ii) Design Chainage Km 33+600 to Km 58+840 Km (Package IV), (iii) Design Chainage Km 58+840 to Km 75+000 Km (Package V) &(iv) Design Chainage Km 75+000 to Km 90+210 Km (Package VI)”.-- 1 Professional Staff 2 Team Leader Cum Senior HighwayEngineer (1 nos.) (1x18+1x15) 3 ResidentcumHighway Engineer (1 nos.) (1x18+1x60) 4 Bridge/Structural Engineer (1 nos.) (1x18+1x10) 5 Senior Quality cum Material Expert (1 nos.) (1x18) 6 Senior Geotechnical Expert (1 nos.) (1x10+1x3) 7 Senior Geologist (1 nos.) (1x10+1x3) 8 Road Safety Expert (1 nos.) (1x6+1x10) 9 Tunnel Safety Exper (1 nos.) (1x5+1x5) 10 Sub-Professional Staff 11 Survey Engineer (02 nos.) (2x18+1+1x10) 12 Lab Technician (02 nos.) (2x18) 13 Assistant Quality cum Material Engineer (02 nos.) (2x18) 14 Quantity Surveyor (02 nos.) (2x18+1x8) 15 Assistant Highway Engineer (1 nos.) (1x18+1x60) 16 Support Staff (inclusive of per diem allowance) 17 Office Manager (1 nos.) (1x18+1x60) 18 Accountant cum Cashier (1 nos.) (1x18+1x60) 19 Steno cum Computer Operator (1 nos.) (1x18+1x60) 20 Office Boy (1 nos.) (1x18+1x60) 21 Transportation : The vehicles provided by the Consultants shall include the cost for rental, drivers, operation, maintenance, repairs, insurance, etc. for all complete approx. 3000km/month run 22 Bolero or equivalent 4 x 4 vehicles (not more than 3 years old) (3x18+1x60) 23 Duty Travel to Site(Fixed Costs): Professional and Sub-Professional Staff. 24 Employers Head Office (1x30) 25 Employers regional Office (1x30) 26 Office Rent (Fixed Costs) The rent cost includes electricity and water charges, maintenance, cleaning, repairs, etc. 27 One Office of Minimum 200 sqm area shall be rented at one location in midway of project during Construction & Maintenance Period (1x18+1x60) 28 Office Supplies, Utilities and Communication (Fixed Costs): Office Supplies, Drafting Supplies, Computer Running Costs, Domestic and International Communication 29 During Construction Period (1x18) 30 During Maintenance Period (1x60) 31 Office Furniture and Equipment (Rental) : The cost shall include rental charges towards all such furniture and equipment as required for proper functioning of office. Office furniture shall include executive tables, chairs, visitor chairs, steel almirahs, computer furniture, conference table etc. Office equipment shall include as a minimum of telephone (2 external & 10 internal lines), photocopier (15ppm, 12000 copies per month with A3 & A4 input), PCs (5 No., Intel Core i3, 19’’ colour TFT, Cache-6MB, RAM-2 GB, HDD-250 GB, DVD Writer, Key board, optical scroll mouse, MS- Windows 8/10, pre-loaded anti-virus etc.), laser/colour printers (2 no., 14 ppm, 266 MHZ, 5000 pages per month, 600x600 dpi or better etc.), Engineering Plan printer (1 no.), binding machine (1 no.), plotter A0 size, overhead projector, AC (4 no., 1.5 Ton), Water Coolers (as required)etc. 32 During Construction Period (1x18) 33 During Maintenance Period (1x60) 34 Reports and Document Printing 35 Monthly reports(Construction and Maintenance) [3x4x(18+60)] 36 Half yearly Reports [3x{(3x3)+(4x10)}] 37 Various others reports as provided in the Contract Agreement such as Completion Report [03 (After Project Completion) + 04 (After completion of Maintenance period)] 38 Cost towards Road Survey Equipment (Network Survey Vehicle/Falling Weight Deflectometer/Mobile Bridge Inspection Unit/Retro Reflectometer) including all required manpower, software & report processing etc. 39 Surface defects detection and roughness measurement using Network Survey Vehicle (57.71 km x 11) 40 Pavement strength measurement using FWD(57.71 km x 6) 41 Bridge inspection using Mobile Bridge Inspection Unit(57.71 km x 10) 42 Road signs inspection using Retro Reflectometer(57.71 km x 11) 43 Contigencies A fixed amount of Indian Rupees Ten Lakh (Rs 10,00,000/-) shall be included in the Financial Proposal
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
9.
Tourism #10881944 Technical Bid
Tender for Furniture Supplying Of Bed Headboard Paneling Made In 19Mm Marine Plywood With 0.1Mm Laminate Finish From Outside And In Middle Bed Headboard With Foam 32D And Fabric As Chosen For The Back Restoration Size: 14Ft X 4Ft , Supplying Of Designer Molding Above The Bed Headboard With Wooden Patti 2 X 1 With Designer Patti With Deco Paint Finish. Size: 14Ft X 1Ft With Concealed Coved Light On The Headboard . , Supplying Of Double Bed Made In 19Mm Marine Gurgen Plywood With 0.1Mm Laminate Finish Brand Greenply Century Or Equilant Brand. Size: 78 X 72 X 16 , Supplying Of Bed Side Table Made In 19Mm Marine Gurgen Plywood With 0.1Mm Laminate Finish Brand Greenply Century Or Equilant Brand. Size: 18 X 16 X 24 , Supplying Of Non Woven Wallpaper Above The Bed Headboard Including Installation Charges. Size: 11Ft X 4Ft , Supplying Of Dressing Unit Made In 19Mm Marine Gurgen Plywood With 0.1Mm Laminate Finish Brand Greenply Century Or Equilant Brand With 4Mm Mirror Company Saint Gobin With Appropriate Handles And Fixtures. Size: 36 X 90 X 26 , Supplying Of Dressing Unit Stool Made In Sal Wood Frame With High Density Foam And Fabric As Per The Chosen. Size: 20 X 24 X 18 , Supplying Of Wardrobe Made In 19Mm Marine Gurgen Plywood With 0.1Mm Fabric Colour Laminate Finish Brand Greenply Century Or Equilant Brand With Appropriate Handles And Fixtures With Inside 2 Drawers And Shefls With Access Rod For Hanging Cloths Wardobe Size: 4.6Ft X 7Ft X 24 , Supplying Of Luggage Rack Made In 19Mm Marine Gurgen Plywood With Teakwood Frame Size 2 X 1.5 With 18Mm Stone Marble Finish With Edged Polished On Top. Size: 3.10Ft X 2Ft X 22 , Supplying Of Tv Unit Made In 19Mm Marine Gurgen Plywood With 0.1Mm Glossy Colour Laminate Finish Brand Greenply Century Or Equilant Brand With Appropriate Handles And Fixtures With Inside 2 Drawers. Size: 6.7Ft X 2Ft X 24 , Supplying Of Working Desk Made In 19Mm Marine Gurgen Plywood With 0.1Mm Glossy Colour Laminate Finish Brand Greenply Century Or Equilant Brand With Appropriate Handles And Fixtures With Inside 2 Drawers. Size: 3Ft X 2Ft X 24 , Supplying Of Working Desk Chair Made In Teakwood Frame With High Density Foam And Fabric As Per Chosen With Melamine Polish. , Supplying Of Curtain Pelmet Made In 16Mm Marine Plywood With Laminate Finish With Double Curtain Tracks. Size: 11.4Ft X 2Ft , Curtain Fabric Main (80% Blackout With 100% Polyster Material Easy To Maintain Wash) Brand - Ddecor Size: 11.4Ft X 8.5Ft , Curtain Fabric Sheer (100% Polyster 54 Width Light Weight Easy To Maintain Wash) Brand - Ddecor Size: 11.4Ft X 8.5Ft , Curtain Installation And Stitching Charges For Window Size: 11.4Ft X 8.5Ft , False Ceiling Made In Gyproc Borad With Required Metal Support / Chanel Patti / Rafter Patti / L Patti (Isi Marked ) Etc. All The Materials Used For The Above Item Shall Confirm To The Latest Relevant Is Standards. Size: Size: 22.5Ft X 11.6Ft Including Cutiing Charges For Light Fixtures And Ac Drains , Supplyng Of Sofa Arm Chair Made In Sal Wood Frame With High Density Foam And Fabric Suede Type 400Gsm Fabric As Per The Selection. Size: 30 X 18 X 20 , Supplying Of Center Table Made In Teakwood Frame With Melamine Polish With Top 12Mm Clear Glass. Size: 3Ft X 2Ft , Bathroom Fixtures Providing & Installtion Of Sanitory Ware - Counter Top Basin Brand - Hindware/ Kohler/ Cera / Parryware / Jaguar Or Equilant Other Brand With Bottle Trap 300Mm And Polished Chrome. Model No. K-7314In-Cp , Sanitory Counter - Carcass- Made Of 50Mmx 50Mm Gi Tube Coverd With Marine Plywood / Acrylic Limaniate / Top Made Of Indian Stone - Granite / Jaislermer/ Makrana Etc Edges Witll Diamond Polished With Blunt Edge Profile / Led Lighting / Dustbin & Tissue Throw Cut Provisioned , Western Styled Toilet Seat - Make Of Cera/ Hindware/ Jaguar Etc , With Health Faucet, Tab, Tissue Holder / Storage Tank Etc With Installation , False Ceiling - Made Of Grid Pattern Pvc Multiwall Celing , Supplying Of Toilet Door Made In Teakwood Frame With 20Mm Blockboard With Laminate Finish With Appropriate Hanges And Handles- With 304 Ss Accessories - Auto Door Closer , Mirror -6Mm Clear Mirror Float Glass All Edge Polished Height - 3.5 Ft , Width As Per Requirement - Irrespetive Of Small Or Big Sizes Pof Area Mounted On 16Mm Thick Marine Plywood , Exhuast For Urinal Area And Basin Area 4 Dia Pvc Pipe Ducting / Inline Fan Etc , Supplying Of Square Shower Head With Shower Arm In Polished Chrome - Model No. K226451n-Cp - Brand - Kohler , Supplyin Of Square Hand Shower Without Hose In Polished Chrome - Model No. K970091n-Cp , Supplying Of Bath Spouts With Diverter In Polished Chrome - Model No. K-2351In-Cp , Supplying Of Shower Enclosure With Toughned Glass And Hanges And Fittings With Rubber - Model No. K-704699In-Shp (Id2p-S In) Upto 3000 Mm Running Length , Supplying Of Angle Valve And Polished Chrome - Model No. K-23515In-4-Cp , Supplying Of 2 Way Bib Tap In Polished Chrome - Model No. K-20075In-4-Cp , Supplying Of Click Drain Big Cap In Polished Chrome - Model No. K-7120In-Cp , Supplying Of Towel Shelf In Polished Chrome - Model No. K-25066In-Cp , Supplying Of Square Tissue Holder With Cover In Polished Chrome - Model No. K-25071In-Cp , Supplying Of Towel Ring In Polished Chrome - Model No. K-5631In-Cp , Supplying Of Tissue Holder In Polished Chrome - Model No. K-5632In-Cp , Supplying Of Soap Dish In Polished Chrome -Model No. K-5634In-Cp , Supplying Of Tumbler Holder In Polished Chrome - Model No. K-5637In-Cp , Supplying Of 6L Step Can In Stainless Still Dustbin _ Model No. K-17531T-St , Bath Of Bath Grip In Polished Chrome - Model No. K-10701D-Cp , Supplying Of Outdoor Furniture Chairs Made In Aluminum 18 Gauge Pipe With Plastic Cane With High Density Foam Using Outdoor Sunbrella Fabric All Weather Proof As Per The Design Selected. Size: 30 X 20 X 18 , Supplying Of Outdoor Furniture Center Table Made In Aluminum 18 Gauge Pipe With Plastic Cane As Per The Design Selected. Size: 3Ft X 2Ft , False Ceiling Made In Pvc Sheet For Outdoor Use Using Gyproc Borad With Required Metal Support / Chanel Patti / Rafter Patti / L Patti (Isi Marked ) Etc. All The Materials Used For The Above Item Shall Confirm To The Latest Relevant Is Standards Including Cutiing Charges For Light Fixtures And Ac Drains , Designing Of Floor Plan For The Layout Purpose Including 3D And 2D With Floor Plans False Ceiling, Tiling, Furniture, Plumbing And Electrical Designing. , Designing Of 3D With Colours Scheme And Cordination With Execution Planning And Statistics Including Space Management And Consulting Charges , Electrical Items 25Mm Condut Pipe - Brand Sudhakar , 25 Mm Junction Box - Brand Sudhakar , 25 Mm Bend - Brand Sudhakar , Insulation Tape - Sudhakar , 1 Module Plate Metal Box - Brand Legrand Lyncus , 2 Module Plate Metal Box - Brand Legrand Lyncus , 3 Module Plate Metal - Brand Legrand Lyncus , 4 Module Plate Metal Box - Brand Legrand Lyncus , 6 Module Plate Metal Box - Brand Legrand Lyncus , 8 Module Plate Metal Box - Brand Legrand Lyncus , 1 Sqmm Wire - Brand Polycab , 1.5 Sqmm Wire - Brand Polycab , 2.5 Sqmm Wire - Brand Polycab , 4 Sqmm Wire - Brand Polycab , Cat 6 Cable - Brand D Link , 1 Module Plate - Brand Legrand Lyncus , 2 Module Plate - Brand Legrand Lyncus , 3 Module Plate - Brand Legrand Lyncus , 4 Module Plate - Brand Legrand Lyncus , 6 Module Plate - Brand Legrand Lyncus , 8 Module Plate - Brand Legrand Lyncus , 5 Amps Switch - Brand Legrand Lyncus , 5 Amps Sockets - Brand Legrand Lyncus , 15 Amps Switch - Brand Legrand Lyncus , 15 Amps Socket - Brand Legrand Lyncus , Telephone Socket - Brand Legrand Lyncus , Outside Room - Bell Push Switch - Brand Legrand Lyncus , Room - Regulator - Brand Legrand Lyncus , Room - Main Switch Key Tag - Brand Legrand Lyncus , Room - Fan 48 Inches - Orient,Havells, Crompton , Balcony - Fan 24 Inches - Orient,Havells, Crompton , Bathroom - Celing Exhaust - Brand Orient,Havells, Crompton , Bathroom - Geyser 5L - Brand Crompton, Recoilt , Room - 12 Watt Cob - Brand Panasonic, Wipro, Philips , Bathroom And Wardrobe - 7 Watt Cob - Brand Panasonic, Wipro, Philips , Room - Strip Light 24O Led , Balcony - 12 Watt Cylinder , Room - 3 Module Laser , Balcony - Bollard , Room - Hanging Light , Bathroom And Dressing - Picture Light , Bed Side - Wall Lamp , Corridor - Surface Panel - Brand Panasonic, Wipro, Philips , Wardrobe - Cabinet Light - Brand Wipro, Ledure , Wardrobe - Wardrobe Sensor- Brand Sensonova , Bathroom - Bathroom Sensor - Brand Sensonova , Room - Bell , Room - Foot Lamp (Indoor) , Balcony - Foot Lamp (Outdoor) , Electrical - Wiring And Cabling, Switches And Sockets Installation, Lighting Fixtures And Rectification, Concealed Work Conduit Laying ,Final Inspection , Room - Tv (43 Inches) , Room - Fridge , Room - Kettle , Bathroom - Hair Driyer , Bathroom - Hanging Telephone , Room - Telephone , Room -Digital Locker , Door - Door Lock Rfid - Brand Yale, One Touch, Goderej , Corridor - 25 Mm Conduit (1.2 Mm ) 3 Mtr - Brand Sudhakar , Corridor - 1 Sqmm Multistand - Brand Polycab , Corridor - Surface Panel 15 Watt - Brand Panasonic, Wipro, Philips , Corridor - 4 Module Plate - Brand Legrand , Corridor - 6 Amps Switch - Brand Legrand , Corridor - 4 Module Metal Box - Brand Legrand , Labour Charges For Electrical Work , 25 Mm Conduit (1.2 Mm ) 3 Mtr- Brand - Sudhakar- For Corridor , 25 Mm Band - Brand - Sudhakar , 25 Mm J Box - Brand - Sudhakar , 2.5Sq Mm Wire - Brand - Polycab , 1 Sqmm Multistand - Brand Polycab For Corridor , Surface Panel 15 Watt - Brand Panasonic, Wipro, Philips , Mcb Box - Brand Legrand , Mcb 32 annual periodical maintenance 3 Pole - Brand Legrand , Mcb 16/32 - Brand Legrand , 4 Module Plate - Brand Legrand , 6 Amps Switch - Brand Legrand , 4 Module Metal Box , Erting , Civil Works Breaking Of Toilet Wall And Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block - D3,D8,D7,D5,D6,D1,D4 , Breaking Of Waterproofing In Sunken Area For Provision Of Plumbing Pipes, Shifting The Debris, And Disposing Off The Same Including Cost Of Transportation, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing Crystaline Waterproofing For Toilet Sunk And Wall Upto 1Mtr Height, Including Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Filling Sunken Slab With Hard Laterite Or Rubble Stone Upto 200Mm Ht, With 1:3 Cement Mortar Mixed With Waterproofing Compound, Including Material And Labour Complete. Block D2,D8,D7,D5,D6,D1,D4 , Providing And Applying Smooth Waterproof Cement Plaster 18Mm Thich In Cement Mortar (1:3) To Reinforced Cement Concrete And Masonary Surfaces Mixed With Waterproofing Compound, Including Smooth Patra Finish, With Material And Labour And Material Complete. Block D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing Single Coat Plaster For Toilet Walls Upto 12Mm Thick In (1:4) Cement Mortar, Including Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing In Position Readymade Tiles Of Nitco,Somany, Kajaria Make Of Approved Colour And Sizein Dado/Wall As Per Design, Including Cutting To Proper Size, Fixing To Level In Cement Paste, Filling The Joints With Matching Colour, With Material And Labour Complete (Basic Rate = Rs 800/Sq.Mtr) Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing Granite Counter For Wash Basin In Toilet, Including Full Moulding For Edges, With Material And Labour Complete.(Basic Granite Rate = Rs. 200/Sq.Ft) Block D2,D3,D7,D5,D6,D1,D4 , Breaking Of Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Skirting Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Balcony Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Balcony Skirting Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Balcony Coping Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D8,D7,D5,D6 , Providing And Laying In Position Readymade Floor Tile For Flooring Of (Size 2*2/4*2)Size Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Skirting Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D32,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Balcony Flooring Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Skirting Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Balcony Coping Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D8,D7,D5,D6 , Breaking Of Concrete Sopo In Balcony, Shifting The Debris And Disposing Off The Same Including Transportation Construction Block D2,D3,D1,D4 , Breaking Of Old Damaged Plaster From Internal Ceiling And Wall. Block D3,D8,D7,D6,D1,D4 , Providing And Fixing Single Coat Plaster For Ceiling And Walls Upto 12Mm Thickness, In (1:4) Cement Mortar, Including Material And Labour Complete. Block D8,D7,D6,D1,D4 , Breaking Of Passage Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Tile From Pardi Top,Wall Tile In Staircase, Staircase Step, Ground Floor Passage Floor,External Steps,Duct And Store Room Floor,External Step For Block 1 & 4 , Breaking Of Passage Floor Skirting Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete.Ground Floor Passage Flooring, Duct And Store, Staircase Skirting , Providing And Laying In Position Readymade Floor Tile For Flooring Of (Size 2*2/4*2)Size Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. First Floor Passage Flooring, Tile From Pardi Top, Ground Floor Passage Floor, Duct And Store Room Floor , Providing And Laying In Position Readymade Floor Tile For Skirting Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. First Floor Passage Flooring, Ground Floor Passage Flooring, Duct And Store, Staircase Skirting , Providing And Laying In Position Jet Black Granite In, Steps Tread As Directed To Proper Levels And Lines Including Setting In Cement Mortar (1:3) 25Mm Thk And Joined With Cement Slurry, With Material And Labour Complete. Staircase Step, External Step , Painting Work Application Of 1 Coat Damp Proof Primer And 2 Coat Apex Ultima Paint For Ceiling And Walls, Including Cost Of Scaffolding, With Material And Labour Complete. , Application Of 2 Coat Cement Based Putty, 1 Coat Internal Primer And 2 Coat Premium Emulssion Paint For Ceiling And Walls, Including Material Nad Labour Complete. Room No. D5,D6,D7,D8,D1,D4,D2,D3 , Application Of 1 Coat Primer And 2 Coat Ace Emulsion For Ceiling And Walls Of Staircase And Passage, Including Material And Labour Complete. , Application Of Oil Paint For Railing And Grill, Including Material And Labour Complete. , Plumbing Work Providing And Fixing Upvc Pipes For External Work Confirming To (Astral Flow Guard/Supreme ) Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fitting S Including Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Cheses And Testing 11/2 Pipe Ing Upvc Pipes For External Work Confirming (Astral Flow Guard/Supreme ) Having Thermal Stability For Cold Water Supply Including All Upuc Plain Elbow Tee And Fitting S Including Jointing Of Pipes And Fittings With One Step Upvc Solvent Cement And The Cost And Testing 11/2 Pipe , Providing And Fixing Upvc Pipes For External Work Confirming To (Astral Flow Guard/Supreme ) Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fitting S Including Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Cheses And Testing 11/2 Pipe Ing Upvc Pipes For External Work Confirming (Astral Flow Guard/Supreme ) Having Thermal Stability For Cold Water Supply Including All Upuc Plain Elbow Tee And Fitting S Including Jointing Of Pipes And Fittings With One Step Upvc Solvent Cement And The Cost And Testing 2 Pipe , Providing And Fixing S.W.R Soil And Waste Pipes. Isi Marking/ Rubber Ring Joints All Special Such As Bends,Tee, Reducers Etc.4 Pipe , Providing And Fixing S.W.R Soil And Waste Pipes. Isi Marking/ Rubber Ring Joints All Special Such As Bends,Tee, Reducers Etc.21/2 Pipe , Providing And Fixing Pvc Drenej Pipes Line Including All Fitting Such As Bends ,Tee, Reducers Support Etc 6 Pipe , Providing And Fixing Pvc Drenej Pipes Line Including All Fitting Such As Bends ,Tee, Reducers Support Etc 11/2 Pipe , Providing And Fixing Pvc Rain Water Pipes Including All Fitting Such As Bends ,Tee, Reducers Support Etc 4 Pipe , Providing And Fixing Pvc Ac Drenej Pipes Line Including All Fitting Such As Bends ,Tee, Reducers Support Etc 3/4 Pipe , Providing And Fixing Pvc Floor Trap 110×75 Mm Self Cleansing With Or Without Went Arm Inlet Receiving Cap For Inlet Dia 50And 40 Mm Complete Including Cutting And Marking Good Wall And Floor , Providing And Constricting With First Class Bricks In Cement Mortar 23 Cm Wall Of Inspection Chamber Laid Over A Bed Of Cement Concrete Inside Plastering Thick With Cement Morter Finished With Floating Coat 24×24 Size Including Providing C.I Man Hole Cover With Frame , Providing And Constricting With First Class Bricks In Cement Mortar 23 Cm Wall Of Inspection Chamber Laid Over A Bed Of Cement Concrete Inside Plastering Thick With Cement Morter Finished With Floating Coat 18×18 Size Including Providing C.I Man Hole Cover With Frame , Providing And Fixing Brass Ball Valves Having Pressure Rating Of 20 Bar Make Molotov Or Equivalent 2 Size , Providing And Fixing Brass Ball Valves Having Pressure Rating Of 20 Bar Make Molotov Or Equivalent 11/2 Size , Providing And Fixing Pvc Rigid Water Storage Tank Of 2000 Ltr. Of Sintex And Shakti, Plasto, Supreme Make At All Heights And Level ,,Make Including All Necessary Fixing , Wall Mounted P Trap Water Closet Providing And Fixing In Position First Quality European Type Standard Wall Mounted Model No. Sls-Wht 6953 Including Heavy Solid Plastic Seat Cover With Rubber Buffer Flap Cover , Providing And Fixing Gabriet Or Equivalent Type Plastic Concealed Cistern With Dual Flush 6/3 Ltr Including Water Supply Connection Code No.110.121.00.1 , Concealed Type Flush Control Plate Of Gabriel Make Model No .115.045.21.3 , Providing And Fixing In Position White Under Counter Wash Basin Of Jaqwar Make Model No Fnswht-.40701 Or Equivalent Of Approved Quality With Jaquar Make Series Waste Coupling Model No. 709 Bottle Trap Model No. Acd7696-300×190 Connection Pipes , Providing And Fixing Two Way Bib Cock Model No. Opp-Chr-15041 Of Jaqwar , Providing And Fixing Health Faucet Of Jaqwar Model No. 573 , Providing And Fixing Basin Mixer Model No. Opp-150053 Of Jaqwar , Providing And Fixing Angel Stop Cock Of Jaqwar. Make Continental Seris Model No. 053 Kn , Providing And Fixing Single Lever Diverter Exposed Parts Kit Of Jaqwar Make Opel Prime Series Model No.Opp-15079Nkpm , Providing And Fixing Concealed Body For Single Lever Diverter Of Jaqwar Make Model No.Ald-Chr-079N , Providing And Fixing Overhead Shower Shower Arm Model No.Shp479l450 Ohs-Chr-1603 , Providing And Fixing Bathtub Spout And Hand Shower Of Jaqwar Make Model No.Spj-Chr-15463 , Providing And Fixing Concealed Stop Cock Of Jaqwar Make Model No. 089 ,083 , Providing And Fixing Nahni Trap S.S Jally 6×6 , Providing And Fixing Pressure Pump 1.5 Kg Of Make V Guard , Providing And Fixing Of Storage Heater With Heating Capacity Of 10 Ltr Make Recold Eterno Make Or Equivalent With Necessary Inlet And Outlet With Flexible Pipes , Roofing Removel Of Existing Battens, Asbestos Sheets, Battens, Mangalore Tiles And Fabricated Structure With Acp Sheets , Fabrication Of 2Ft X 2Ft Grid Over The Existing Roof Slab, Iko Cambridge Shingle (30 Year Warranty), Membrane (Asian Paints) 3 Mms, Bitumen Primer, Ridge, 16Mm Fiber Cement Board, Aluminum Drip Edge, Installation, Transport, Handling & Gas , Facia (8Inches) , Upvc Gutters 6Inches
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
12.
Housing Urban and Rular Development #10778167 Price Bid
Tender For Maintenance of Road (Project-126 Model Road) Noida - Earth work in excavation by Mecanical means ( Hydraulic Excavator ) Manual means over Areas Exclooding 30cm in Depth , 1.5m in With as well as 10 Sqm on Plan including getting out and disposal of Excavated earth load upto 50 m and Lift upto 1.5m as direction by engineer in Charge . The Contractor has defect different utilities like Sever line, water supply line, electric cable , Telephone Cable , Gas Pipe line Etc. using Utility Detecting Machine Before Start of Excavation and Shall atart Excavated only After Getting Permission on E/I. 2 Providing and laying Cement concrete with 4cm gauge approved stone ballast, approved coarse sand and cement in the proportion of 1:4:8 (1 cement ; 4 Coarse sand : 8 graded Stone Ballast 40mm. Nominal size.) including supply of all materials, labour and T & P etc. required for proper completion of the work. 3 Providing and laying Cement concrete with 4cm gauge approved stone ballast, approved coarse sand and cement in the proportion of 1:3:6 (1 cement ; 4 Coarse sand : 8 graded Stone Ballast 40mm. Nominal size.) including supply of all materials, labour and T & P etc. required for proper completion of the work. 4 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 5 Fabrication & Manufacturing of Prestressed Hollow Core slab (Hollow area 25 to 30%) of different thickness nodular width 1200 mm in Controlled Factory Envionment with approved methodology confirming to IS 10297:1982 by using long line casting method having arrangement of proper steel bed. Concreting should bel done by batch mixing plant capable of producing zero slump concrete, transported through automatic shuttels off tandard make & layed on bed with the help of extruder/Slipfonner, finishing, curing and also provision off steam curing. Cutting, making necessary cutout/holes of required sizes for services in stab element after achieving required strength, yard handling & stacking all complete as per approved shop drawings & design mix as per the direction of the Engineer-in-change. (Cost of strands should be paid separately) Note: Exces/less cement over the specified cement content used as per design mix is payable/recoverablo separatcly) icluding steel & Transport charge. 150 mm thick hollow core stab Providing and laying in position cument 6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth and above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 7 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. 8 Brick work with Common Brunt clay F.P.S( Non-modular) bricks of class designation 100 in foundation and plinth in:Cement mortar 1:4 (1 cement :4 coarse sand) 9 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 10 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 11 12mm cement plaster on of mix: 1:4 (1 cement : 4 coarse sand) 12 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 13 Providing wall putty on Old Surface with Approved Quality Material of Berger/J.K/Birla or Similar make 2 Coats. 14 Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 15 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 16 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 17 Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. 18 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 19 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). 20 Providing and Fixing of Multi cell Polycarbonate Panels 12 mm Danpalthick with 3 cells 4 walls structure over MS Supporting structures / MS frame (Paid separately). Panel Width shall be600-900 mm to ensure best performance for wind uplift. The panels shall be uniform in color with an integral Multi-Cell core. In a cross section, the core shall be constructed of Microcell of max 4.5mm x4.5 mm and soft light finish DG both side. The appearance should be either rectangular/tight cell like to giveMR highest resistance to impact and hail damage. The weight of theSqm 5205;$208.00 panel only shall not be less than 1550 gram per square meter. panel should have co-extruded UV protection with U value 2.4 RCHIW/M2.K and UV transmission less than 0.1% with UV filtration test AS No. 1067-1990. Panel and system should have impact and shock resistance with D1-10j -M 50,300 J-M 50 400 J. I DEL Polycarbonate panels also shall have Yellowness Index as perASTM D 1925 and sample exposed to UV for minimum 2000Hrs. Panel should (have fire test-Bsido.5205.70/3gm Lowest rates reicud 21 Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 to 1.00 kg/sqm using mechanical means. 22 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm 23 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe 24 Demolishing cement concrete including disposal of material within 50 metre lead: Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 25 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 26 Extra for cutting reinforcement bars in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) 27 Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work. 28 Dismolishing brick work manually / by mechanical means including stacking of sericeable material and disposal of unserviceable material within 50 metre lead as per direction of engineer- in- charge. In cement mortar 29 Removing mortar form bricks and cleaning bricks including stacking within a lead of 50m (stacks of cleaned bricks shall be measured): From brick work in cement mortar 30 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. 31 Dismantling including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.Water bound macadam road 32 bituminous road 33 Dismantling Kerb Stone (Dismantling kerb stone by manual means and disposal of dismantled material with all lifts and up to a lead of 1000 metre) 34 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge 35 Disposal of building rubbish / malba / similarunserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer- in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 36 TR Concrete bench Supply of concrete bench as per approved design casted in FRP mould for uniform surface straingthness and appropriate edge precasted with M-25 concrete mix appropriate reinforcement, the other surface to be coated with sealer. 37 Providing and fixing of Signage of Size 3000x600x150mm height approx in MS finished as per attached drawing/image and placing on finished platform as attached drawing without damaging the edges complete as per instruction from consultant and Engineer-in-charge. 38 Providing and fixing of Decorative wall (IAM NOIDA) of Size 5000mm height approx in 75x100mm MS sections with letters in laser cuttring aluminium finished as per attached drawing and placing in position without damaging the edges complete as per instruction from consultant and Engineer-in-charge. 39 Providing and fixing of Colourful swing sculptures of Size 3000mm height approx in 1000x500mm MS finished as per attached drawing and placing in position without damaging the edges complete as per instruction from consultant and Engineer-in-charge. 40 Providing and fixing of MS Sphere entry of 2100mm height approx in 304 SS finished as per attached drawing and placing in position without damaging the edges complete as per instruction from consultant and Engineer-in-charge. 41 White Marble Modern Art Ht. 120 (3 nos of each set) 42 Concrete bench with planter supply of glass fiber reinforced concrete bench as per approved design, the planter should be casted in fiber reinforced plastic molds allowing tolerence +10 mm. The wall thickness should be minimum 25 mm, casted in portland cement based of J.K. Cement, Ultratech or equivalent, using appropriate reinforced with alkali resistence glass fiber rainging from 3 to 5% of N.E.G. Japan or ownes cornng. The bench should be pigmented with synthetic oxide non fading water proof, UV resistance pigment of M/s Bayferrox / Lanxess of equivalent. The outer surface need to be coated with sealer. 43 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 44 P/F of 4050 mm dia granite polished spheres with base plate of granite 45 Dustbin-MSWDBANALYSIS OF RATEDim:- 370 L x 340 w x 875 H mm.Capacity- 50 Ltr.Construction:-GI. powder coated frame with 70 x 12 mm synthetic wood planks cladding (synthetic wood is a composite material of wood & plastic which makes it termite free and weather resistance & has a good self life). 46 Providiing and fixing of 8x8 metal kiosk with canopy on windows and completely locable as approved by architect. 47 CNC Jali 4 mm powder coated MS Sheet 4874.12-18% GST 48 P/F of Saucer drain of Size 600x300x100 m (along the side) in PCC (1:1/2:3) Complete and provide proper slope of drain of rainwateron the top of drain including all lead lift etc complete for the fineshedItem of work as per direction Engineer in charge. Note: ( No Separate measurement will be considered for the excavation) : M 40 Grade. 49 Supply of Labour Complete at site on etc. in all respect as per direction of engineer in charge. 50 Supply of Tractor with Trolley Complete at site on hire basis including cost of diesel and driver etc. complete in all respect as per direction of engineer in charge. 51 Supply of J.C.B. Complete at site on hire basis including cost of diesel and driver etc. complete in all respect as per direction of engineer in charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Uttar Pradesh View Result →
13.
Drinking Water Supply and Sanitation #10713558 Price Bid
Different Works Related To Water Supply Scheme At Duna & Its Adjoining Mouzas Water Supply Scheme Within Mayureswar-Ii Block Including Supply Of All Labour & Materials Underbirbhum Division, Phe Dte. ( Sl. No.11 ) - Sinking Of Tubewell- 3 Nos. ( Annexure I ) Site Preparation, Temporary Latrine, Placement & Levelling Of Rig Machine, Mast Hoisting And Casing Drilling ( Upto 6 Mtr. ) Placement Of Casing With All Allied Works Necessary To Commence Drilling Woks And Wind Up Of All Machineries After Completion Of Drilling. 2 Drilling By Direct Rotary Method Of Drilling Using9 7 / 8” Dia.Bit For Pilot Bore Follwed By Subsequently Reaming Using 12 1 / 4” Dia. , 15 Dia. And 17.5 Dia. Rock Roller Bits / Drag Bits In Consolidated, Semi Consolidated And Soft Formation Up To Required Depth Including Casing Boring And Casing Lowering As Required Includingcost Of Fuels And Lubricants Etc. As Required For Drilling.Note:1 ) Rate Only For Pilot Drilling Will Be @ 50%. Of Item Rate.2 ) Ratefor Reaming By 12 1 / 4 Dia. Bit Will Be @ 14% Of Item Rate.3 ) Ratefor Reaming By 15 Dia. Bit Will Be @ 16% Of Item Rate.4 ) Ratefor Reaming By 17.5 Dia. Bit Will Be @ 20% Of Item Rate. From 6 Mtr. To 60 Mtr. 3 From 60 Mtr. To 90 Mtr. 4 From 90 Mtr. To 120 Mtr. 5 From 120 Mtr. To 150 Mtr. 6 From 150 Mtr. To 180 Mtr. 7 Lowering The Tube Well Assembly ( Upvc Casing Pipe , Well Pipe, Strainer Along With Upvc Accessories ) Vertically In A Position With Proper Lowering Arrangement By Applying Necessary Jointing Compound Including Labour Cost For Subsequent Gravel Packing And Machine Operation Cost Etc. 8 Cost Of Consumables For Drilling Rigs And Machineries. 9 Development ( Min. 8 Hr. Continuous ) Of Tube Well By Using Suitable Air Compressor ( Min. Capacity: 600Cfm & Operating Pressure 14 Bar ) Followed By Yield Testing With Bht Pump ( Head :45 To 50Mtr., Discharge :1100 To 1000 Lpm And 25 Bhp Engine ) All Complete Includingto & Fro Transportation Cost And Cost Of Fuels, Lubricants & Labour Etc. 10 Water Sample Collection And Chemical Test Including Arsenic Test. 11 Transportation Cost Of Drilling Equipmentand Accessories Rig Machine Etc. Including Cost Of Fuel, Lubricant & Loading Unloadingthe Materials From Store / Stack Yard / Suppliers Godown And Unloading / Stacking The Same At Site. ( Upto 60.0 Km Distance ) 12 Supply And Delivery Of Upvc Pipe ( Cd ) Conforming To Is 12818:2010. ( Cipet Certified ) . ( 250 Mm Dia. ) 13 Supply And Delivery Of Upvc Pipe ( Cd ) Conforming To Is 12818:2010. ( Cipet Certified ) . ( 150 Mm Dia. ) 14 Supply And Delivery Of Upvcdeep Well Screen ( Rds ) Pipes With Ribs Conforming To Is 12818:2010 . ( Cipet Certified ) 150 Mm Dia. 15 Supply And Delivery Ofupvcreducer 250Mm X 150Mm Dia. 16 Supply And Delivery At Site Of Upvc End Cap. ( 250 Mm Dia. ) 17 Supply And Delivery At Site Of Upvc End Cap. ( 150 Mm Dia. ) 18 Supply And Delivery Of M.S. Housing Clamp 250 Mm Dia. 19 Supply And Delivery Of M.S .Centre Guide ( Special Type ) . 20 Supply And Delivery Of Washed Gravels Size Ranging From 1.80 Mm To 4.74 Mm. Conforming To Is 4097 : 1967. 21 Supply And Delivery Of Bentonite Powder Conforming To Is 6186 : 1986. 22 Electro-Logging Charge. 23 Trial Boring Of Tube-Welldrilling By Reverse Rotary Method Of Drilling Using9 7 / 8” Dia.Bit For Pilot Bore Follwed By Subsequently Reaming Using 12 1 / 4” Dia. , 15 Dia. And 17.5 Dia. Rock Roller Bits / Drag Bits In Consolidated, Semi Consolidated And Soft Formation Up To Required Depth Including Casing Boring And Casing Lowering As Required Includingcost Of Fuels And Lubricants Etc. As Required For Drilling.Note:1 ) Rate Only For Pilot Drilling Will Be @ 50%. Of Item Rate.2 ) Rate For Reaming By 12 1 / 4 Dia. Bit Will Be @ 14% Of Item Rate.3 ) Rate For Reaming By 15 Dia. Bit Will Be @ 16% Of Item Rate.4 ) Rate For Reaming By 17.5 Dia. Bit Will Be @ 20% Of Item Rate.From G.L. To 60 Mtr. 24 From 60 Mtr. To 90 Mtr. 25 From 90 Mtr. To 120 Mtr. 26 From 120 Mtr. To 150 Mtr. 27 From 150 Mtr. To 180 Mtr. 28 Cleaning Compound Premises Of Shrubs, Plants, Jungled Etc. As Per Direction Of E.I.C. 29 Soil Test For Ohr- 1 No. ( Annexure Ii ) Mobilisation Charges Of All Tools & Plants Along With Accessories, Material, Labour, Supervision Etc. At Site Of Work Required In Connection With Boring And Testing Work, Including Setting Up Boring Rigs And Shifting To Different Bore-Hole Points Etc. And Also Including Withdrawal Of Same From The Site After Completion Of Work, Complete As Per Direction Of Engineer-In-Charge. 30 Labour For Making Bore-Holes Of 150Mm To 250Mm Dia. By Any Standard Method To Any Depth Below Ground Level / Bed Level In All Kinds Of Soil Like Clay, Silt, Sand, Stiff Clay, Mixed Soils Etc. Except Rocks ( For The Purpose Of Collecting Disturbed & Un Disturbed Soil Samples, Conducting Standard Penetration Test At Suitable Intervals Etc. ) Including Preparation And Submission Of Bore-Log As Per Irc : 75 And 78 And Clause 2400 Of Specifications For Road & Bridge Works ( 5Th Revision ) , Published By Irc, And Also Including Hire Charges Of Tools And Plants Complete As Per The Direction Of Engineer-In-Charge.A ) When Casing Pipe Is Used To Prevent Collapse Of Bore Hole ( Casing Pipe To Be Finally Withdrawn ) I ) Depth 0 M To 10 M ( For 3 Nos Bore ) 31 Ii ) Depth Greater Than 10 M & Upto 20 M 32 Iii ) Depth Greater Than 20 M & Upto 30 M 33 Field Investigation :I ) Collection Of Undisturbed Soil Sample From The Bore Hole To Be Made By The Concerned Division / Party At Their Cost.A ) 0.00 - 10.0 M 34 B ) 10.00 - 20.0 M 35 C ) 20.00 - 30.0 M 36 Ii ) Collection Of Samples From The Bore Hole ( A ) Disturbed 37 Iii ) Standard Penetration Tests ( S.P.T. ) By Split Spoon Sampler In The Bore Hole As Per Is : 2131.A ) 0.00 - 10.0 M 38 B ) 10.00 - 20.0 M 39 C ) 20.00 - 30.0 M 40 Laboratory Investigation :I ) Liquid Limit As Per Is 2720 ( Part – V ) . 41 Ii ) Plastic Limit As Per Is 2720 ( Part – V ) 42 Iii ) Grain Size Analysis By Sieving As Per Is 2720 ( Part – Iv ) . 43 Iv ) Grain Size Analysis By Hydrometer Method As Per Is 2720 ( Part – Iv ) . 44 V ) Determination Of Water Content As Per Is 2720 ( Part – Ii ) . 45 Vi ) Determination Of Specific Gravity As Per Is 2720 ( Part – Iii ) . 46 Vii ) Direct Shear Test As Per Is 2720 ( Part – Xiii ) . 47 Viii ) Determination Of Unconfined Compressive Strength As Per Is 2720 ( Part-X ) ( I ) Undisturbed 48 Ix ) Determination Of Consolidation Properties As Per Is 2720 ( Part – Xiv ) . 49 X ) Tri-Axial Shear Test :A ) Determination Of Shear Strength Parameters Of A Specimen Tested Inunconsolidated Undrained Tri-Axial Compression Without Measurement Ofpore Water Pressure As Per Is 2720 ( Part –Xi ) . 50 Carriage Of All Disturbed & Undisturbed Samples From Site Of Work To The Divisional Office Or Elsewhere Including Loading And Unloading As Per Direction Of Engineer-In-Charge. Detailed Investigation. 51 Preparation And Submission Of Report In 6 ( Six ) Copies, Giving All Relevant Information Data Like Site Plan, Bore Log And Water Table, Test Results, Calculations, Discussions, Suggestions And Recommendations In Respect Of Suitable Foundation Etc. Including Determination Of Silt Factor Calculation Of Waterways And Complete Design Of Foundation Including Analysis Of Bearing Capacities And Settlements In Bound And Presentable Form Complete As Per Direction Of Engineer-In-Charge.Detailed Investigation. 52 Construction Of 300 Cum Ohr- 1 No. ( Annexure Iii ) Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete. A ) Depth Of Excavation Not Exceeding 1500 Mm 53 B ) Depth Of Excavation For Additional Depth Beyond 1500Mm And Upto 3000Mm. ( But Not Requiring Shoring ) . 54 Bailing Out Water From Foundation Trench. This Item Should Be Executed On The Specific Direction Of The Engineer-In-Charges When He Is Satisfied In His Absolute Discretion, That This Has Not Been Necessitated Due To Any Fault On The Part Of The Contractor ) 55 Hire And Labour Charges For Shoring Work ( Including Necessary Close Plank Walling, Framing, Eucalyptus / Jhau Balla Pilling, Strutting Etc ) Complete As Per Directionof The Engineer-In-Charge For Foundation Excavation ( Vertical Surface Are In Contact With Supported Earth Is To Be Measured. ) ( This Item Should Be Executed On Specific Direction Of The Engineer-In-Charge ) .A ) Depth Upto 1.5M. 56 B ) For Additional Depth Beyond 1.5M And Upto 3.00M. 57 Earth Filling In Foundation Trenches Or Plinth With Good Earth In Lyres Not Exceeding 150Mm Including Watering & Ramming Etc Layer By Layer Complete.A ) With Earth Obtained From Excavation Of Foundation. 58 Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm As Directed And Consolidating The Same By Thorough Saturation With Water, Ramming Complete Including The Cost Of Supply Of Sand. ( Payment To Be Made On Measurement Of Finished Quantity ) Do - By Fine Sand 59 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming And Dressing Bed To Proper Level, And Filling Joints With Powered Earth Or Local Sand. 60 Cement Concrete With Graded Stone Chips ( 20Mm Size ) Excluding Shuttering, In Ground Floor ) Considering 30 Km Distance From Suri Rly. Yard.A ) 1:2:4 Proportion. ( In Foundation And Under Tank At Finished Gl, Plinth Protection Etc. ) 61 Controlled Cement Concrete With Well Graded Stone Chips ( 20Mm Nominal Size ) Excluding Shuttering & Reinforcement With Complete Design Of Concrete As Per I.S.456 And Relevant Special Publications, Submission Of Jobs Mix Formula After Preliminary Mix Design After Testing Of Concrete Cubes As Per Direction Of Eic. Consumption Of Cement Concrete Will Not Be Less Than 300Kg Of Cement With Super Plasticizer Per Cubic Meter Of Controlled Concrete But Actual Consumption Will Be Determined On The Basis Of Preliminary Test And Job Mix Formula. ( Using Concrete Mixture ) .Considering 60 Km Distance From Suri Rly. Yardm- 25 Grade ( With Pakur Variety. ) A ) For Works In Foundation, Basement And Upto Roof Of Ground Floor / Upto 4M. 62 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 63 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 64 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 65 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 66 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Bottom Of Heal Beam 67 Controlled Cement Concrete With Well Graded Stone Chips ( 20Mm Nominal Size ) Excluding Shuttering & Reinforcement With Complete Design Of Concrete As Per I.S.456 And Relevant Special Publications, Submission Of Jobs Mix Formula After Preliminary Mix Design After Testing Of Concrete Cubes As Per Direction Of Eic. Consumption Of Cement Concrete Will Not Be Less Than 300Kg Of Cement With Super Plasticizer Per Cubic Meter Of Controlled Concrete But Actual Consumption Will Be Determined On The Basis Of Preliminary Test And Job Mix Formula. ( Using Concrete Mixture ) . Considering 60 Km Distance From Suri Rly. Yardm- 30 Grade ( With Pakur Variety. ) A ) Heal Beam And Above ( Cell Wall, Floor, Top & Bottom Ring Beam, Heal Beam ) A ) 6Th Floor 68 B ) 7Th Floor 69 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4M Using Approved Stout Props And Thick Hard Wood Planks Of Approved Thickness And Required Bracing For Concrete Slabs, Beams, Column Lintel Curved Or Straight Including Fitting, Fixing And Striking Out After Completion Of Woks ( Upto Roof Of Ground Floor ) .Steel Shuttering Or 9 To 12Mm Thick Approved Quality Ply Board Shuttering In Any Concrete Work.C ) For Foundation Upto G.L. 70 Hire And Labour Charges For Shuttering For Concrete Work In Overhead R.C. Reservoir On Separate R.C. Frame Including Fitting, Fixing And Striking Off After Completion Of Work Including Staging Upto 4M Using Ply Board Or Steel Shuttering. ( Not Applicable For Resting On Roof Top ) .A ) G.L. To Top Lantern Of Ohr. 71 Hire And Labour Charges For Staging Beyond 4M With Necessary Cross Bracing And Fixtures And Removing The Same After Completion Of The Work All Complete As Per Direction Of The E.I.C. [ Mode Of Measurement :Area Of Unsupported Horizontal Projection ( Where Staging Beyond 4M Is Practically Un-Avoidable ) X Mean Height Of Staging ] Above Initial 4M. ( Dia 10.50 M. Mean Height 16M. ) 72 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc. , Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Inter-Section, Complete As Per Drawing And Direction. I ) Tor Steel / Mild Steeli. Sail / Tata / Rinl A ) For Works In Foundation Basement Upto Roof Of Ground Floor / Upto 4 M . 73 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 74 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 75 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 76 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 77 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Top Of Heal Beam 78 G ) 6Th Floor I.E. From Top Of Heal Beam To Top Ofshell Wall 79 H ) 7Th Floori.E. From Top Of Shell Wall To Rest 80 Applying 2 ( Two ) Coats Of Bonding Agent With Synthetic Multi Funtional Rubber Emulsion Having Adhesive And Water Proofing Properties By Making With Water In Proportion ( 1 Bonding Agent : 4 Water : 6 Cement ) As Per ManufacturerS Specification. 81 Extra Rate For Using Water Proofing And Plastering Admixture @ 0.2%By Weight Of Cement ( Or At ManufacturerS Specified Rate For Concrete Of Various Grades ) . 82 Supplying, Fitting, Fixing Fly / Mosquito Proof Nylon Net On Any Type Of Window, Doorshutter Frame With Necessary Fixing Arrangements Complete. 83 Supplying Fitting And Fixing Door Made With Irc Febric Mesh Of 75Mm X50mmx4.5Mmx2.7Mm On 50Mm X 50Mm X 6Mm Angle Iron Frames All Round And One 37.5Mm X 6Mm M.S. Flat Bar Over The Netting All Round Welded To Angle Iron Frame And Providing Locking Arrangements If Necessary And With Two Coats Of Synthetic Enamel Paint ( Other Than Hi-Gloss ) Fitted And Fixed With Clamps Or Haskal Doomney Etc. Complete At The Lantern Of R.C.C. Over Head Reservoir. 84 Artificial Stone In Floor, Dado, Staircase Etc. With Cement Concrete ( 1:2:4 ) With Stone Chips, Laid In Panels As Directed With Topping Made With Ordinary Or White Cement ( As Necessary ) And Marble Dust In Proportion ( 1:2 ) Including Smooth Finishing And Rouding Off Corners And Including Raking Out Joints Or Roughening Of Concrete Surface Andapplication Of Cement Slurry Before Flooring Works, Using Cement @ 1.75 Kg / Sq.M. All Complete Including All Materials And Labour.In Ground Floor 3 Mm Thick Topping ( High ) Polishing, Grinding On This Item Is Not Permitted With Ordinary Cement ) .25 Mm Thick.A ) In G.F For Plinth Protection And Under Tank Floor 85 B ) 6Th Floor 86 C ) 7Th Floor 87 M.S. Structural Works In Columns, Beams Etc. With Simple Rolled Structural Members ( E.G. Joists, Angle, Channel Sections Conforming To Is: 226, Is: 808 & Sp ( 6 ) - 1964 Connected To One Another With Bracket, Gussets, Cleats As Per Design, Direction Of Engineer-In Charge Complete Including Cutting To Requisite Shape And Length, Fabrication With Necessary Bolting, Metal Arc Welding Conforming To Is: 816- 1969 & Is: 1995 Using Electrodes Of Approved Make And Brand Conforming To Is:814- 2004, Haulage, Hoisting And Erection All Complete. The Rate Includes The Cost Of Rolled Steel Section, Consumables Such As Electrodes, Gas And Hire Charge Of All Tools And Plants And Labour Required For The Work Including All Incidental Chages Such As Electricity Charges, Labour Insurance Charges Etc. Payment To Be Made On The Basis Of Calculated Weight Of Structural Members Only In Finished Work As Per Is Specified Weight. Payment For Gusset, Bracket, Cleat, Rivets, Bolts And Nuts May Be Make By Adding The Actual Weight Of Such Items With The Weight Of Finished Structural Members Or 7% Of Weight For Finished Structural Members Weighing Not Less Than 22.5 Kg. / M. Or 15 % Of Weight For Finished Structal Members Weighing Less Than 22.5 Kg. / M. May Be Increased Allow For Bracket, Cleat, Rivet, Bolts And Nuts Etc. And No Seperate Payment Being Made For These Items, As Per Direction Of Engineer In Charge. The Rates Are Considered For A Height Of Erection 8M. / 2Nd Floor Level From The Ground. Add 1.5% Extra Over The Rate For Each Additional Floor Or 4M. Beyond Initiial 8M. Or Part Thereof.Iii ) For Built Up Sections / Srtuctural Members Of Specified Sections Weighing Not Less Than 22.5 Kg. / M 88 M.S. Gate Of Jail Type As Per Approved Design Made Of Strong M.S. Frame Work, Intermediate Stiffeners And Round / Square Bars Or Angles. M.S. Sheet ( Not Less Than 14 Gauge ) Gussets, Cleats Etc. Including Necessary Riveting, Bolting, Welding, Locking And Hanging Arrangements, Fitting And Fixing Complete As Per Direction Of The Engineer-In -Charge. 89 M.S. Or W.I. Ornamental Grill Of Approved Design, Joints Continuously Welded With M.S. Wi Flats And Bats For Winding, Drilling Etc.Fitted & Fixedwith Necessary Screw And Lugs In Ground Floor.A ) Grill Weighing Above 10 Kg / Sqm Upto 16 Kg / Sqm ( In Kg ) 90 Supplying, Fitting, Fixing900 Mm High G.I. Pipe Railing For R.C.C Stair Cat Ladder Walk Way Fabrication, Erection, Welding Of 40 Mm G.I ( Non Tata Medium ) Pipe Place At Top Of Railingand2 Nos 25 Mm Dia. G.I Pipe ( Non Tata Medium ) Placed Equally In Between Railingtop & Floor, Vertical Post Of Raillingare 40 Mm Dia. G.I Pipe ( Non Tata Medium ) Placed At 900 Mm C / C . The Each End Of The Vertical Post Is Join By The 62 Mm ( 25 Mm X 6 Mm X 0.062 M Long ) Ms Flat And 150 Mm Length ( Propes Pipes ) Are Grouted In Concrete Base Of Stair, Walk Way Etc. All Complete With Supplying Of All Materials Including Hoisting Up To The Any Height Complete With 2 Coats Of Painting With Super Gloss ( Hi Gloss ) In Any Shade Except White And Black Over A Coat Of Primer Complete As Per Direction Of E.I.C.Analysis Of Rate Enclosed In Seperate Sheets. ( Analysis Rate ) 91 Supplying At Site Hoisting, Fitting, Fixing Erecting And Building In Position Where Necessary 450Mm.Wide Ladder As Per Design Consisting Of 2Nos. M.S.Plate Of 8Mm.Thick With Necessary Base Plate 60Mm Wide; And 16Mm.Dia M.S.Round Or Square Bar As Steeps Placed @ 300 C / C Including Fabrication, Welding Drilling Etc. As Per Drawing And Direction And Finished With Two Coats Of Synthetic Enamel Painting Over A Coat Of Red Lead Primer Etc. All Complete As Per ;Direction Of The Eic 92 Supplying Fitting And Fixing In Position C.I Manhole / Pit Cover With Rim.A ) Square.I ) 600 X 600Mm ( 50Kg.Approx ) . 93 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Superstructure Ground Floor ( 1:6 ) 94 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand Cement Mortar Including Rounding Off Or Chambering Corners As Directed And Raking Out Joints Including Throating Nosing And Drip Course Scafolding / Staging Where Necessary ( Ground Floor ) Excluding Cast At Shipping Over Concrete Surface. Ii ) With 1:4 Cement Mortar ( 10 Mm Thick Cement Plaster ) A ) G.L. To Top Of 1St Bracing 95 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 96 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 97 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 98 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 99 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Bottom Of Heal Beam 100 G ) 6Th Floor I.E.From Bottom Of Heal Beam To Top Of Ring Beam 101 H ) 7Th Floori.E. From Ring Beam To Rest 102 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand Cement Mortar Including Rounding Off Or Chambering Corners As Directed And Raking Out Joints Including Throating Nosing And Drip Course Scafolding / Staging Where Necessary ( Ground Floor ) Excluding Cast At Shipping Over Concrete Surface. Ii ) With 1:3 Cement Mortar ( 10 Mm Thick Cement Plaster ) A ) 6Th Floor 103 B ) 7Th Floor 104 Supplying & Installation Of Lighting Solid Conductor Rod Of Phosphorous-Bronze Size 2M X 12Mm On The Top Dome Of The Rcc Overhead Reservoir, Laying Lightning Conductor Of 65Mm X 8Mm G.I. ( Hot Deep ) Ms Flatruns From The Roof Upto Gl Along The Shell Wall And Colume Fitted With Necessary Rust Proof Clamps, Lying65mm X 8Mm G.I. ( Hot Deep ) Ms Flat Conductorfrom Gl To Bottom Of The Earthing Main Pipe 80Mm Dia. Tata ( M ) Fitted And Fixedand Connecting With The Main Earthing Gi Pipe Of 80Mm.Dia Tata ( M ) Of 2.50M To Be Used As Earthing Electrode Driven Down To At Least 3.0M Below Gl And Filling Up With Charcoal, Construction Of Masonry Chamber Making As Per Direction Of Eic & Necessary Arrangement For Testing The Same As Per Iee Rule. ( All Work To Be Done As Specification Of Pwd ( Elec. ) Schedule. ) 105 Provision For Embossing The Name And Capacity Of The Reservoir With ( 2:1 ) Raised Sand Cement Plaster With Letter Size 30Cm. X 20Cm. On The Outside Of Shell Wall Of The Reservoir Painted Complete As Per Direction Of Eic. 106 Protective And Decorative Acrylic Exterior Emulsion Paint Of Approved Quality, As Per Manufacturer’S Specification And As Per Direction Of Eic To Be Applied Over Acrylic Primer As Required. The Rate Includes Cost Of Material, Labour, Scaffolding And All Incidental Charges But Excluding The Cost Of Primer. ( Two Coats. ) I ) Super Protective 100% Acrylic Emulsion.A ) G.L. To Top Of 1St Bracing 107 B ) From Top Of 1St Bracing To Top Of 2Nd Bracing 108 C ) From Top Of 2Nd Bracing To Top Of 3Rd Bracing 109 D ) From Top Of 3Rd Bracing To Top Of 4Th Bracing 110 E ) From Top Of 4Th Bracing To Top Of 5Th Bracing 111 F ) From Top Of 5Th Bracing To Top Of Heal Beam 112 G ) From Top Of Heal Beam To Top Of 1 / 3Rd Of Shell Wall 113 H ) From 1 / 3Rd Of Shell Wall To Rest 114 Applying Exterior Grade Acrylic Primer Of Approved Quality And Brand On Plastered Or Concrete Surface Old Or New Surface To Received Decorative Textured ( Matt Finish ) Or Smooth Finish Acrylic Exterior Emulsion Paint Including Scraping And Preparing The Surface Thoroughly, Complete As Per Manufacturer’S Specification And As Per Direction Of The Eic. ( Two Coats ) A ) G.L. To Top Of 1St Bracing 115 B ) From Top Of 1St Bracing To Top Of 2Nd Bracing 116 C ) From Top Of 2Nd Bracing To Top Of 3Rd Bracing 117 D ) From Top Of 3Rd Bracing To Top Of 4Th Bracing 118 E ) From Top Of 4Th Bracing To Top Of 5Th Bracing 119 F ) From Top Of 5Th Bracing To Top Of Heal Beam 120 G ) From Top Of Heal Beam To Top Of 1 / 3Rd Of Shell Wall 121 H ) From 1 / 3Rd Of Shell Wall To Rest 122 Neat Cement Punning About 1.5Mm Thick In Wall, Dado, Window, Ceiling, Floor, Drain Etc. 123 Priming One Coat On Steel Or Other Metal Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothing Surface By Sand Pepering Etc. 124 Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening Surface By Sand Papering Etc Including Using Of A Approved Putty Etc On The Surface If Necessaryon Steel Or Other Metal Surface ( With Other Than Hi Gloss Of Approved Quality ) . I ) 2 Coats ( With Any Shade Except White ) 125 Painting With Ready Mixed Black Japan Of Approved Make And Brand Including Smoothening Surface.Two Coats. 126 Making Arrangement For Showing The Water Tightness Test Of The Rcc Elevated Reservoir By Filling With Water Upto The Maximum Level Of The Tank To The Full Satisfaction Of Eic ( Arrangements Of Water, Its Carriage And Lifting To The Tank Including Necessary Pipes, Fitting, Pumping Machinery Etc. Are To Be Provided By The Contractor With His Own Cost. ( If Water Is Supplied By The Department Rate Shall Be Reduced As Per Prevailing Departmental Rate ) ) 127 Disinfection And Washing The Tank And Pipe Connections Including Cleaning The Inside Of The Etc. Complete. 128 Hoisting, Erection , Placing Connecting With Pipes And Specials Cidf Pipes, Specials ) Securing With Building Specials Providing Stays, Clamps As Required Including Cost Of Staging Platform For The Work Etc.All Complete In All Respects As Per Drawing And Direction Of Eic.A ) 250Mm.Dia . 129 B ) 150Mm.Dia . 130 C ) 100Mm.Dia . 131 Laying Of Cidf / D.I Pipes With Specials, Valves Etc. In Trenches Including Excavation In All Sorts Of Soil, Moorum, Soft Rock And Refilling The Trenches After Laying & Jointing Of Pipes Etc. All Complete As Per Specification And Direction Of Eic.A ) 250Mm.Dia . 132 B ) 150Mm.Dia . 133 C ) 100Mm.Dia . 134 Fitting, Fixing Duct-Foot Bend Including Construction Of Cement Concrete ( 4:2:1 ) Base With Stone Chips Ofapproved Grade & Quality & Including Excavation Of Earth Etc Complete In All Respect. ( Analysis Rate ) A ) 250Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 135 B ) 150Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 136 C ) 100Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 137 Hoisting, Fitting, Fixing Of Ci Bell Mouth With Puddle Collar In Rcc Work As Per Drawing Specification Complete In All Respect.A ) 250Mm.Dia . 138 B ) 150Mm.Dia . 139 C ) 100Mm.Dia . 140 Construction Of Masonry Drain 300 Mm X 250 Mm Inner Section With 1St Class 250 Mm Th. Brick Work In Cement Mortar ( 1:4 ) Over A Layer Of Single Brick Flat Soling , Sand Filling 100Mm Th. And 100 Mm Th. Weak Cement Concrete ( 6:3:1 ) With Graded Stone Ballast Pakur Variety ( 40Mm Size ) Including Earth Work In Excavation, 15Mm Th. Cement Plaster ( 4:1 ) And Neat Cement Punning All Rounding The Drain Etc. All Complete As Per Approved Design , Drawing And Direction Of The Engineer In-Charge. ( Analysis Rate ) 141 Supply And Delivery Of Different Dia.Cidf Pipe ( Class - B ) I.S: 1538 - 1976 & Specials ( Class - B ) As Per Is: 1538 - 1993 With Latest Amendment Including Loading, Unloading & Stacking Properly For Connection Of Inlet, Outlet, Overflow And Washout Line Of Ohr As Per Departmental Drawing With Specified Dia. Inclusive Of All Incidental Charges If Any All Complete As Per Direction Of The E.I.C. ( Test Certificate From The Manufacturer And Guarantee Certificate Should Be Produced By The Agency ) 142 A ) Supply And Delivery Of Cidf Sluice Valve Pn-10 Of Different Dia Make With Cast Iron Double Flanged Non Rising Spindle Sluice Valve Generally Conforing To I:S 14846-2000 With Latest Amended If Any Having Body Door Dome / Bonnet And Cover Of Cast Iron Gr.- F.G. 200 ( Ref. Is-210 ) Spindle Of Is: 6603 Gr.- 12 / Cr. 13 Non-Magnetic, Nut And Seat Rings Are Gunmetal As Per Is: 1538 Part Iv & Vi Valves Are Suitable For Maximum Working Pressure Of 10Kg / Sq.Cm. ( Seat Test ) And Body Tested To 15Kg / Sq.Cm. ( Test Certificate From The Manufacturer As Well As Inspection Certificate From Third Party Inspection, Agency To Be Arranged By Their Own Cost And To Be Approved By E.I.C. ) N.B. The Above Item Should Be Procured From The Reputed Manufacturer Viz- Kalpana, Jupiter & Upadhaya Or Similar Approved Vender List. [ With Cap ] A ) 250Mm.Dia . 143 B ) 150Mm.Dia . 144 C ) 100Mm.Dia . 145 Construction Of R.C.C. Inlet & Overflow Chamber As Per Drawing Cast With Rcc Wallwithcement Concretenot Leaner Than 1:1.5:3 With Graded 20 Mm Down Pakur Variety Stone Chips And Reforcement Having Wall Thickness 125 Mm And Complete With Plastering 15Mm Th. ( 1:4 ) With Neat Cement Finishing And As Per Direction Of The E.I.C. ( Inner Size = 600 Mm X 600 Mm X 750 Mm ) ( Analysis Rate ) 146 Applyingwate Thinable Non-Toxic Acrylic Polymer Modified Paint Coating Or Equivalent Brand Of Approved Quality 2 ( Two ) Finished Coats Over 2 Coats Of Primer Of Same Brand To The Ceiling Of Roof Dome Including Supplying Supplying Requisite Coating Materials Cleaning Of The Substrant Properly To Make It Free From Dirt, Paint, Oil And Grease Sludge, Blisters, Fungus , Moss, And All Other Undesireble Particles Using Wire Brush , Sand Paper Etc. Including Mending Good All Damages All Complete As Per Direction Of The E.I.C. 147 Supplying Hoisting, Fitting Fixing Approved Type Water Level Indicator With Copper Float, Guide Pulley, Wire Boards Etc. As Per Standard Specification And Direction And Satisfaction Of Eic 148 Site Clearence By Removing All Unserviceablematerials, Debris Etc. All Complete As Per Direction Of E.I.C. 149 Construction Of 3 Nos Pump House And Boundary Wall With Land Development ( Annexure Iv ) Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete.Depth Of Excavation Not Exceeding 1, 500 Mm. 150 Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm. As Directed And Consolidating Same By Thorough Saturation With Water Ramming Complete, Including The Cost Of Supply Of Sand. 151 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming Anddressing Bed To Proper Level And Filling Joints With Local Sand. 152 Ordinary Cement Concrete ( 1:2:4 ) With Graded Stone Chips ( 20 Mm Size ) Nominal Size Excluding Shuttering And Reinforcement , If Any In Ground Floor As Per Relevant Is Code. ( A ) Pakur Variety 153 Ordinary Cement Concrete ( Mix 1:1.5:3 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes. Pakur Variety 154 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth, In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. ( Payment To Be Made On The Basis Of Measurement Of Finished Quantity Of Work ) ( A ) With Earth Obtained From Excavation Of Foundation. 155 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc. , Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Inter-Section, Complete As Per Drawing And Direction.A ) For Works In Foundation Basement Upto Roof Of Ground Floor / Upto 4 M . I ) Top Steel / Mild Steel [ I. Sail / Tata / Rinl=> Rs.-53241.00 / M; Ii. Other Than Sail / Tata / Rinl=> Rs.-51991.00 / Mt ] 156 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Foundation And Plinth. 157 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Superstructure Ground Floor ( 1:6 ) 158 125 Mm Thick Brickwork With 1St Class Bricks In Cement Mortar ( 1:4 ) In Ground Floor 159 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4 Mtr Using Approved About Props And Thick Hard Wood Planks Of Approved Thickness With Required Bracing For Concrete Slabs , Beams, Columns, Lintels, Curved Or Straight Including Fitting, Fixing & Striking Out After Completion Of Works ( Upto Roof Of Ground Floor ) A ) 25 Mm To 30 Mm Thick Wooden Shuttering As Per Decision & Direction Of Engineer-In-Charge. 160 25 Mm Thick Damp Proof Course With Cement Concrete With Stone Chips ( 3:1.5:1 ) ) ( With Gradedstone Aggregates 10 Mm Normal Size ) And Paintingthe Top Surface With A Coat Of Bitumen Using 1.7 Kg Per Sq M Including Heating The Bitumen And Cost And Carriage Of All Materials Complete. 161 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand & Cement Mortar Includgrounding Off Or Chamfering Corners As Directed A Ramming Out Joints Or Roughening Of Concretesurface By Chamfering Etc. Including Threading Noising And Drip Course Where Necessary. ( Ground Floor ) I ) With 1:6 Cement Mortar.20 Mm Thick Plaster 162 I ) With 1:6 Cement Mortar.15 Mm Thick Plaster 163 I ) With 1:4 Cement Mortar.10 Mm Thick Plaster 164 Supplying Fitting, Fixing- Openable Steel Windows As Per Is Sizes With Side Hung Shutters And Horizotal Glazing Bars With / Without Fixed Type Ventilators. [ The Extra Rate Admissible For The Openable Portion Only ] ( P-82, I-33 ) 165 Supplying 1.5Mm Thick M.S. Sheet Fitted And Fixed On One Or Both Faces Of M.S. / W.I. Gate Etc. With Point Welding At Not More Than150mm Apart Complete In All Respect As Per Design Including Cost Of All Labour And Materials 166 M.S. Or W.I. Ornamental Grill Of Approved Design, Joints Continuously Welded With M.S. Wi Flats And Bats For Winding, Drilling Etc.Fitted & Fixedwith Necessary Screw And Lugs In Ground Floor. ( I ) Grill Weighing Above 10 Kg. / Sq.Mtr And Up To 16 Kg. / Sq. Mtr.Rs.- 8247.00 / Qt, ( Ii ) Grill Weighing Above 16 Kg. / Sq.Mtr And Abovers.-8053.00 / Qt. 167 Applying Decorative Cement Based Paint Of Approved Quality After Preparing The Surface Including Scraping The Same Thoroughly ( Plastered Or Concrete Surface ) As Per ManufactureS Specification In Ground Floor. A ) Two Coats ( On New Cement Plaster Surface ) 168 White Washing Including Cleaning And Smoothening Surfacethoroughly.A ) 3 Coats. 169 B ) Priming One Coat On Steel Or Other Metal Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothening Surfaces By Sand Papering Etc. 170 Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening Surface By Sand Papering Etc Including Using Of A Approved Putty Etc On The Surface If Necessaryb ) On Steel Or Other Metal Surface ( With Other Than Hi Gloss Of Approved Quality ) . I ) 2 Coats ( With Any Shade Except White ) ( Hi Gloss ) 171 Number Plaque Of Buildings ( Plaque Size Upto 225 Mm X 225Mm ) Made Of Cement Plaster ( 2:1 ) On Face Of Wall Or Plinth , With 50 Mm Size Letters P.H.E. And The Number Of The Structure Formed Thereon ( In Sunk Type ) Including Painting The Letters Complete As Per Direction. ( Cement = 1 Kg / No ) 172 Supplying, Fitting And Fixing PeetS Valve Fullway Gunmetal Standard Pattern Best Quality Of Approved Brandbearing I.S.I. Marking With Fittings . ( Tested To 21 Kg / Sq.Cm. ) ( For Water Lines Only ) .- 15 Mm. Dia. 173 Construction Of Septic Tank Of Different Capacities As Per Approved Drawing With 1St Class Brick Work In Cement Mortar ( 1:4 ) Including Two 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Of Approved Make Supplied, Fitted And Fixed In The 100Mm Thick R.C.C ( 1:1.5:3 ) Top Slab With Necessary Fittings, 20Mm Thick Cement Plaster ( 4 : 1 ) With Neat Cement Finish To The Internal Surfaces And 15 Mm Thick Cement Plaster ( 4 : 1 ) To Outside Wall Upto 200 Mm Below G.L Floor Finished With 25 Mm Thick Grey Artificial Stone Over 100 Mm Thick R.C.C ( 1:1.5:3 ) Bottom Slab Including Supplying, Fitting And Fixing All Necessry Specials, Fittings, S.W. Tees, C.I. Foot Rest Etc. Including Excavation Earth In All Sorts Of Soil, Shoring, Bailing Out And Pumping Out Water As Necessary, Ramming, Dressing The Bed And Fefilling The Sides Of The Tanks With Earth, Removing Spoils, Filling Up The Chamber With Clear Water, Removing Foreign Materials From The Chamber And Including Constructing Attached Inspection Pit As Per Approved Drawing And Connecting All Necessary Pipes, Joints Etc. With Internal Plaster Work And Artificial Stone Flooring Is To Be Done With Admixture Of Water Proofing Compound @ 0.5% By Weight Of Cement With All Costs Of Labour And Materials. Note:- ( I ) Finished Level Of Septic Tank Should Be 400 Mm. From Ground Level. ( Ii ) Height Of 50 Mm. Ventilation Pipe &Mosquito Proof Mesh, Should Be Follwed As Per Is:2470, Part I.Payment Will Be Made Separetly On The Basis Of Actual Height Based On Relevant I.S.Code. ( I ) For 10 Usersa ) With Pakur Variety. ( Sail / Tata / Rinl ) 174 Supplying, Fitting & Fixing Orissa Pattern Water Closet In White Glazed Vitreous Chinaware Of Approved Make Supplied , Fitted Fixed In Positioncomplete Excluding P Or S Trap. ( Excluding Cost Of Concrete For Fitting ) I ) 530Mm X 410 Mm 175 Supplying Fitting And Fixing10 Litre Pvc Low-Down Cisternof Conforming To I.S. Specification With Pvc Fitting Complete C.I.Make With Either Side Or Bottom Brackets Including Two Coats Of Painting To Brackets. 176 Supplying Pvc Water Storage Tank Of Approved Quality With Closed Lid ( Black ) -Multilayer. A ) 500 Litre Capacity. 177 Construction Of Circular Soak Well 2.5 Metre Deep In All Types Of Sandy Soils With Dry Brick Work Upto 1.6 Metre From The Bottom Having 150 Mm Intermediate Cement Brick Work ( 1:4 ) Band All Round And Cement Brick Work ( 1:4 ) Upto 0.90 Metre From Top With 20Mm Thick Cement Plastering ( 1:4 ) To Inside Face Upto The Depth Of Cement Brick Work, 15Mm Thick Cement Plaster ( 1:4 ) On Outer Face From Top Of The Well Upto G.L. And 6 Mm Thick Cement Plaster ( 1:4 ) On Top Of The R.C.C. Cover Slab Including Filling Bottom 1.00 Metre Of Inside Of The Well With Brick Metal ( 50 Mm To 63 Mm Size ) Including R.C.C. Cover Slab Of 100 Mm Thick With Cement Conc ( 1:1.5:3 ) With Stone Chips With Necessary Reinforcement And Shuttering Including One 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Of Approved Make Supplied, Fitted And Fixed In The Cover Slab With Necessary Fittings, Making Nacessary Arrangements For Pipe Connections, Excavation Of Well Including Shoring, Dewatering And Removing The Exess Earth From The Premises As Per Direction Complete In All Respect With All Costs Of Labour And Materials. With 250 Mm Thick Dry Brick Work And 250 Mm Thick Cement Brick Work ( 1:6 ) And 1.00M Inside Dia. ( Sail / Tata / Rinl ) 178 Supplying, Fitting & Fixing Upvc Pipes A-Type And Fittings Conforming To Is:13592-1992 With All Necessary Clamps Nails, Including Making Holes In Walls, Floor Etc. Cutting Trenches In Any Soil Through Masonry Concrete Structures Et. If Necessary And Mending Good Damages Including Joining With Jointing Materials ( Spun Yarn, Valamoid / Bitumen / M-Seal Etc ) Complete. ( A ) 75Mm. Dia. 179 Supplying, Fitting And Fixing Fan Hook For Ceiling With1 Metre Long16mm Dia Rod Complete Including Mending Damages .Payment For Damage And Repair To Be Made Separately. 180 Wash Basin White Vitreous China Of Approved Make ( Without Fittings ) Supplied , Fitted And Fixed In Position On 75Mm X 75Mm X 75Mm Wood Blocks And C.I. Brackets Including Two Coats Of Painting Of C.I. Brackets. ( A ) 450 Mm X 300 Mm Size. 181 Supplying, Fitting And Fixing Approved Brand P.V.C. Connector White Flexible, With Both Ends Coupling With Heavy Brass C.P. Nut, 15 Mm Dia. ( A ) 900 Mm Long. 182 Cutting Holes And Subsequent Mending Good Damages. 183 Supplying , Fitting And Fixing 30 Mm. Thick Both Side Prelaminated Factory Made Solid Panel Pvc Door Shutter Consisting Of Outer Frame Made Out Of Ms Tubes Of 19 Gauge Thickness And Size 19 Mm. X 19 Mm. For Styles, Top And Bottom Rails, Ms Frame Shalll Have Cost Of Steelprimers Of Approved Make And Manufacture, M.S Frame Cover With 5 Mm.Thick Head Moulded Pvc C Channel Of Size 30 Mm. Thick 70Mm. Width Out Of Which 50 Mm. Shall Beflat And 20Mm. Shall Be Tapered In 45 Degree Angle Of Either Side Forming Styles, And 5Mm Thick 95 Mm. Wide Pvc Sheet Out Of Which 75 Mm. Shall Be Flat And 20 Mm. Tapered In 45 Degree On The Inner Side Toform Top & Bottom Rail And 115Mm.Wide Pvc Sheet Out Of Which 75 Mm. Shall Be Flat And 20 Mm. Shall Be Tapered On Both Sides To Form Lock Rail. Top Bottom And Lock Rails Shall Be Provided Either Side Of The Panel With 10Mm. ( 5Mm. X 2 Mm. ) Thick , 20 Mm. Wide Cross Pvc Sheet As Gap Insert For Top Rail And Botttom Rail Sheet To Be Fitted In The M.S Frame Weled / Sealed Tothe Styles &Rails With 7 Mm. ( 5Mm. + 2 Mm. ) Thick X 15 Mm. Wide Pvc Sheet Beading On Inner Side And Joint Together With Solvent Cement Adhesive . An Additional 5 Mm. Thick Pvc Strip Of 20 Mm. Which Is To Be Stuck On The Interior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Com Excluding All Necessary Hardwire As Per Direction Of The E.I.C In Ground Floor. 184 Supplying Fitting Approved Type Ventilator In Position After Cutting Holes In Walls, Setting In Cement Mortar, Mending Damages To Wall And Plaster And Two Coats Of Paint Of Approved Brand Sand Shade .Payment Of Mending Two Damages Of Wall & Plaster And Painting To Be Made Separately.R.C.C. Ventilator Of 20 Mm Thick - Upto 0.10 Sq.M. Area 185 Constructing Inspection Pit Of Inside Measurement 600 Mm X 600 Mm X Upto 600 Mm ( Depth ) With 250 Mm Thick 1St Classbrick Work In Cement Mortar ( 1:4 ) On All Sides , Bottom Of The Pit Consisting Of 100 Mm Thick Cement Concrete ( 1:3:6 ) With Stone Chips Over A Layer Of Jhama Brick Flat Soling, 15 Mm Thick ( 1:4 ) Cement Plaster To Inside Walls And Outside Walls Upto Gl And 20 Mm Thick ( 1:4 ) Plaster To Bottom Of The Pit, Providing Necessary Invert With Cement Concrete ( 1:3:6 ) With Stone Chips As Per Direction, Neat Cement Finishing To Entire Internal Surfaces, Top Of The Pit Covered With 100 Mm Thick Rcc Slab ( 1:1.5:3 ) With Stone Chips And Necessary Reinforcements Upto 1% And Shuttering Including 6 Mm Thick Cement Plaster ( 1:4 ) In All External Surfaces Of The Slab And One 560 Mm Dia Rcc Manhole Cover Of Approved Make Supplied, Fitted And Fixed In The Slab With Necessary Fittings, Necessary Earth Work In Excavation In All Sorts Of Soil, Filling Sides Of The Pit With Earth And Removing Spoils After Work Complete In All Respects With All Costs Of Labour And Materials. -With Pakur Variety. 186 Supplying , Fitting And Fixing Cast Iron P Or S Trap Conforming To I.S. 3989 / 1970 And 1729 / 1964 Including Lead Caulked Joints And Painting Two Coats To The Exposed Surface. ( Painting To Be Paid Seperately ) .- S Trap - 100 Mm. 187 Supplying, Fitting And Fixing Alloy Iron With Brass Spindle Bib Cock / Stop Cock Of Approved Brand And Make, Spray Painted And Tested To 21 Kg Per Sq.Cm. - 15 Mm. Dia. 188 Supplying, Fitting And Fixing Approved Patent Vent Cowl I.C.I. Conforming To I.S.S And Painting Two Coats To The Exposed Surface With Approved Paint Complete. ( Payment Of Painting Will However Be Paid Seperately ) .- 100 Mm Dia. 189 Supplying, Fitting And Fixing Pillar Cock Of Approved Make. A ) I ) Cp Pillar Cock-15 Mm ( Equivalent To Code No-507 & Model - Tropical / Sumthing Special Of Essco Or Similar Brand ) . 190 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. A ) With Carried Earth Arranged By The Contractor Within A Radius Of 3 Km. Including Cost Of Carried Earth. 191 Laying For Rising Main & Distribuition System With Fhtc ( Annexure V ) Carrying Ci / Di Pipes With Specials And Valves And Lowering Placing In Position And Laying Carefully Inside The Trenches In Proper Alignment And Gradient Etc.Including Earth Work Inexcavation Of Adequate Width As Per Specification Having Min. Clear Cover From Top Of Pipe Is 1.10Mtr. Below Existing Ground Level In Any Kind Of Soil Including Mixed With Boulder, Road Sub-Grade And Its Flank, But Excluding Moorum And Laterite And Stone Etc.Without Damaging The Exisiting Telephone / Electric Cableetc. ( Incaseof Damaged If Any Type Of Cable Line During Excecution , Necessary Damaged Charges As Applicable By The Respective Authority Will Beborne By The Agency In His Own Cost ) Preparing The Bottom Surface For Continuous Bedding Of Pipe Line And Laying Pipes, Fitting, Fixing Specials And Valves With Bailing Out Water If Any Including Carriage Of Pipes, Specials And Valves From Local Deptt.Store Within 8Km And Back Filling The Trenches With Excavated Earth In Layers To Original Condition As Per Specification And Direction Of Eic. The Surplus Materials After Execution Of Work Are To Be Return To The Deptt. Store.N.B: I ) Any Deviation From Required Clear Cover Of 1.10Mtr., Due To Site Adverse Condition, Prior Permission Is To Be Obtained From The Eic In Exceptional Situation And Payment Will Be Made On Prorate Basis Over The Rate Of Entire Item Ii ) No Payment Will Be Made Without Hydraulic Test Of The Pipe Line Either Part Or Full Iii ) Thepipes, Specials And Valves , Rubber Gasket Will Be Supplied Deptt. Free Of Cost.A ) 150Mm Dia. 192 B ) 200Mm Dia. 193 C ) 250Mm Dia 194 Making Rubber Gasket Joint To Ci / Di Pipes Maintaining Proper Alignment Level Etc. By Mechanical Arrangement With Or Without Using Mobile Cranes Where Necessary And With Help Of All Other Equipments Tools And Tackles Etc. As Required Providing Lubricants Of Approved Quality And Direction Of Eic. ( Rubber Gasket Will Be Supplied Deptt. Free Of Cost ) B ) 150Mm Dia. 195 C ) 200Mm Dia. 196 D ) 250Mm Dia 197 Making Flange Joint To Di / Ci Pipes, Specials And Valves Where Necessary With Supply Of Required Rubber Insertion And Nut Bolts, Washers Etc. Of Approved Quality And Type All Complete As Per Specification And Direction Of Eic ( Nut And Bolts Shall Be Of Tata / Gkw Rate ) .A ) 250Mm Dia 198 B ) 200Mm Dia. 199 C ) 150Mm Dia. 200 E ) 100Mm.Dia . 201 Cutting Di Pipe ( All Class & Type ) To Required Length With Cutting Device Etc. And Grinding The Cutting Portion With File As Per Direction And Satisfaction Of Eic.B ) 150Mm.Dia.To 200Mm.Dia Pipe 202 C ) 250Mm.Dia.To 350 Mm.Dia Pipe 203 Chamfering The Spigot End Of All Type / Class Of Di Pipe For Proper Using Of Push Joint By Means Of Grinder Set At Site For Proper Joint Etc. All Complete As Per Direction Of Eic.B ) 150Mm Dia. 204 C ) 200Mm Dia. 205 D ) 250Mm Dia 206 Filling The Pipe Line With Water, Testing Hydraulically As Per I.S 3114-1965 ( Article-6 ) In Section Of A Length Not Exceeding 500Mtr. For Head Of Pressure As Per Specification Including Supplying Installing And Fixing All Equipments Such As Diesel Pump Set, Blank Flange, Pressure Gauge, Valve, Pressure Pump And All Other Tools And Plants Including Drilling Topping And Plugging Of Necessary Holes To Pipes, Blocking Ends Providing Temporary Thrust Block And Subsequent Blocking Of Holes And Other Jointing Materials And Dismantling And Removal Of The Same Including Disposal Of Water Etc. All Complete As Per Specification And Direction Of Eic. The Rate Is Inclusive Of Cost Of Requisite Water To Be Arranged By The Contractor ( Recovery Rate Of Water @ Rs.10.00 / M3, If Contractor Used Water From Deptt. Source ) .A ) For Ci / Di Pipe.A ) 150Mm Dia. 207 B ) 200Mm Dia. 208 C ) 250Mm Dia 209 B ) For Upvc / Hdpe Pipea ) 50Mm ( Od ) 210 B ) 63Mm ( Od ) 211 C ) 75Mm ( Od ) 212 D ) 90Mm ( Od ) 213 E ) 110Mm ( Od ) 214 F ) 125Mm ( Od ) 215 G ) 140Mm ( Od ) 216 H ) 160Mm ( Od ) 217 I ) 180Mm ( Od ) 218 J ) 200Mm ( Od ) 219 K ) 225Mm ( Od ) 220 Cleaning Thoroughly The Inner Surface Of Pipe Line Including Specials And Valves By Flushing With Water And Subsequently Disinfection Of The Same Pipe Line By Flushing Again With Water Containing Bleaching Powder Resulting In Residual Chlorine Not Less Than 15Mg / Ltrs. After 24Hrs. Of Such Filling Including Laboratory Testing Of Water Samples Obtain From The Disinfested Pipe Line And Disposal Of Water From The Pipe Line After Completion Of The Work. The Rates Including Of Cost Of Requisite Water To Be Arranged By The Contractor ) ( The Rate Of Water @Rs. 10 / M3 May Be Recovered, If The Contractor Used Water From Deptt. Source ) .A ) For Ci / Di Pipe.B ) 150Mm Dia. 221 C ) 200Mm Dia. 222 D ) 250Mm Dia. 223 B ) For Upvc / Hdpe Pipea ) 50Mm ( Od ) 224 B ) 63Mm ( Od ) 225 C ) 75Mm ( Od ) 226 D ) 90Mm ( Od ) 227 E ) 110Mm ( Od ) 228 F ) 125Mm ( Od ) 229 G ) 140Mm ( Od ) 230 H ) 160Mm ( Od ) 231 I ) 180Mm ( Od ) 232 J ) 200Mm ( Od ) 233 K ) 225Mm ( Od ) 234 Submission Of Complete Detailed Drawing Of Distribution System, Rising Main Etc. After Execution Of Work Showing Position Of Different Types Of Valves, Fittings / Specials Sluice Valve Chamber With Location, Node To Node Wise In The Sanctioned Drawing As Completion Drawing Of The Water Supply Scheme As Per Direction And Satisfaction Of Eic. The List Of Dia Wise Fitting / Specials, Different Pipes ;Of Valve Used In The Rising Main Should Be Shown In The Completion Drawing ( Not Separate ) With Verified By Sae & Ae In-Charge Of The Scheme. The Above Drawing Will Be Submitted In 5 Copies. 235 Bituminous Pucca Road ( Approx. 450Mm Depth ) Cutting By Using Gaiti, Chisel, Hammer Etc. And Picking Uip The Withdrawing Excavated Materials And Remove The Same Within Distance Of 30Mtr. At Least All Complete For Fixing / Crossing All Dia Of Pipe Line As Per Direction Of Eic 236 Dismantling All Type Of Plain Cement Concrete Works, Stacking Serviceable Materials Of Site And Removing Rubbish As Directed Within A Lead Of 75Mtr. For Laying All Dia Pipe Line In Ground Floor, Upto 150Mm Thick.A ) Upto 150Mm Thick 237 B ) Above 150Mm Thick 238 Construction Of Different Dia Sluice Valve / Air Valve / Washout Chamber In Different Sizes For Village Road Where Light Traffic Run And For Main Road Where Heavy Traffic Run As Deptt.Approved Drawing With 25Cm Thick Brick Work ( 1:6 ) Over Cement Concrete ( 4:2:1 ) Over A Single B / F Soling Over150mm.Thick Sand Filling In Foundation Including Earth Work In Excavation And Disposal Of Excess Earth From Work Site With Rcc ( 1:1.5:3 ) Cover Slab 100Mm / 150Mm Thick Slab On Top Of Chamber With 1% Reinforcement Inrcc Cover Slab With Necessary Opening For Operation Of Valve All Complete Including Cost Of Labour & Materials As Per Departmental Dwg. [ Reinforcement Type:- Other Manufactuerers Not Specified ] I ) 80 Mm To 150 Mm Dia Pipe 239 Ii ) 200 Mm Dia Pipe 240 Iii ) 250 Mm Dia To 350Mm Dia Pipe 241 Making Holes In Two Sides Of Wall Of Culvert / Drain Or Any Other Structuresin Any Places For Laying Any Dia Pipe Line Within Structures Intwo Sides Of Wall Of Culvert / Drain / Any Structure At Any Places And Mending Good Damages All Complete As Per Direction Of Eic. 242 A ) Construction Of Rcc Street Stand Post ( 700Mm Height ) Of Rcc ( 1:1.5:3 ) Footing Over 75Mm Thick 4:2:1 P.C.C Over A Single B / F Soling With 1% Reinforcement, Connected With Saddlepiece & 15Mm Dia Brass Ferrule With Supplying Fitting, Fixing 15Mm Dia G.I. Nipple, G.I.Socket, G.I. 200Mm X 150Mm Reducing Elbow And 20Mm Dia Gi ( M ) Tata Pipe Of ( Avg. ) 2.6Mtr. Long And One 15Mm Dia Alloy Iron With Brass Spindle Bib Cock With Socket And 20Mm G.I. Elbow 2Nos. With 15Mm Gi ( M ) Tata Pipe Of 0.225Mtr. For Connection Of Stand Post To Distribution Line As Per Deptt. Design And Drawing As Per Direction Of Eic Along With Construction Of Platform Of Size Cc Platform ( 1:2:4 ) Over A Single B / F Soling Below G.L Over 150Mm.Thick Sand Filling, Neat Cement Finish Over Platform And Inner Side Of Band And 15Mm Thick Cement Plaster ( 4:1 ) On Top Of Platform Band And Outside Upto G.L. As Per Deptt. Drawing And As Per Direction Of Eic 243 Supplying Hdpe ( Materials Grade Pe-80 ) Pipes Conforming To Is 4984-1995 With Latest Revision & Amendments If Any With Necessary Hdpe Specials ( Excluding Cost Of Cidf Valves ) Including Labour Charges For Earth Work In Excavation In Any Kind Of Soil Including Mixed Soil With Boulder, Road Sub-Grade And Aits Flank But Excluding Moorum Laterite Or Sand Stone / Hard Rock Cutting With Chisel Required Including Cutting Road Flank / Brick Pavement Etc. Without Damaging The Exisiting Telephone / Electrical Cable Line Etc. ( In Case Of Damage Of Any Type Of Cable Line By The Agency At The Time Of Execution Necessary Damage Charge As Applicable By The Respective Authority Will Have To Be Brone By The Agency At His Own Cost ) Upto The Depth ( Av. ) So As To Maintain 1.10M.Earth Cushion From Top Of The Pipe Upto G.L. Including Loading Unloading Carrying Lowering Laying Fitting Fixing Carefully Pipes, Valves And Specials With The All Types Of Jointing Materials In Trenches Maintaining Proper Levels And Alignment Jointing The Pipes And Specials By Butt Welding / Adopting Suitable Method ( But Weld Jointing With Help Ofhydraulic Tack And Trimming Machines, Hitter Etc. For Reaching At Necessary Melting Point Of Hdpe Pipe So That Joint Can Be Monolithic ) So As To Facilitate The Maintenance Of Pipe Line Locally As Per Conventional Method In Future. ( A ) Pressure Rating : Pn 6Ii ) Laying Of Pipe Line Including Cost Of Pipe & Fittings / Specials Butexcluding Cost Of Valvesa ) 50Mm ( Od ) 244 B ) 63Mm ( Od ) 245 C ) 75Mm ( Od ) 246 D ) 90Mm ( Od ) 247 E ) 110Mm ( Od ) 248 F ) 125Mm ( Od ) 249 G ) 140Mm ( Od ) 250 H ) 160Mm ( Od ) 251 I ) 180Mm ( Od ) 252 J ) 200Mm ( Od ) 253 K ) 225Mm ( Od ) 254 Providing Fhtc From The Existing Cl / Dl / Upvc / Hdpe / Gl / Ac Distribution Pipeline By Installing 10 Mm Nb Gun-Metal Ferrule Conforming To Is 2692:1989 With Latest Amendments On The Said Pipeline With Supply, Fitting & Fixing Of All Other Accessories Like Saddle Piece Of Required Size To Fit The Existing Distribution Pipeline, Specials, Nut & Bolts, Rubber Sheet, Washers Etc And Supply & Laying Of 15Mm Nb Pvc ( Schedule 80 ) / 20Mm Od Hdpe ( Peioo, Pn16 ) Pipe ( Average 15M Length ) With All Necessary Specials 1.0 Metre Below The Ground Connecting The Ferrule Including Cutting Trenches In All Sorts Of Soil And Filling Up Trenches As Per Direction Of The Engineer-In-Charge And Upto A Point Just Inside The Premises Of The Household Or As Directed By Eic. Supply And Installation Of A 15Mm Dia. Alloy Iron Bib Cock ( Tested To 21 Kg / Cm2 ) Above 1.0 Mtr. From Ground, An Alloy Stop Cock Of 15 Mm Dia. With Brass Spindle ( Tested To 21 Kg / Cm2 ) To Be Fitted In A Position As Directed By E.I.C. G.L Pipe Of Tata Make ( Medium Duly ) Of 2 Metre Length With All Necessary Specials To Continue From The End Of The Hdpe / Pvc Pipe And Upto 1.0 M Above Ground Within The Premises Of Household.Note : 1. Pvc Pipe Shall Of Schedule 80 ( Medium Duty ) Conforming To Astmd-1785 And Threaded To Match With Gi Pipe As Per Is: 1239 ( Part-I ) .2. Rate Is Exclusive Of Supply And Delivery Of 10Mm Nb Gun Metal Ferrule.3. Payment Of Supply And Laying Of 15Mm Dia Nb Pvc ( Schedule 80 ) Or 20Mm Od Hdpe ( Pe 100, Pn 16 ) Pipe With All Necessary Specials 1.0M Below The Ground Will Be Made On Actual Measurement Basis. The Rate Of This Item Is Rs. 117 / -Per Metre.A ) Upto 10M Length 255 B ) Above 10M Upto 20M Length 256 Colection Of Household Details As Per Prescribed Formatthrough Mobile App / Hard Copies Including Geo Referance As Diected By E.I.C And Submission Of The Same To The P.H.E Dte.In Soft Copies. 257 Ordinary Cement Concrete ( Mix 1:2:4 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement, If Any, In Ground Floor As Per Relevant Is Codes.A ) Pakur Variety 258 Cost For Boring Any Type Of Soil By Augor Boring ( Horizontal ) With Water Jet System Including Hire Charges Of Machine, Tools & Plants, All Complete With All Labour And Supply Of Water Etc. As Per Specification And Direction Of Eic.I ) 80Mm To 100Mm Dia. 259 Ii ) 125 Mm To 200 Mm Dia 260 Supplying, Fitting And Fixing In Position G.I. Pipes Of Tata Make For Underground Works With All Necessary Accessories, Specials Viz.Socket, Bend, Tee, Union, Cross, Elbow, Nipple, Short Piece Etc.Including Cost Of All Materials, Jointing Materials , Cutting Pipes, Making Threads, Cutting Trenches Upto 1.5 Metre Below Surface In All Sorts Of Soil And Refilling The Same As Directed With Two Coats Of Painting On G.I. Pipes And Specials With Bituminous Paint Complete In All Respect. ( Payment Will Be Made On The Centre Line Measurement Of The Total Pipe Line Including All Specials No Separate Payment Will Be Made For Accessories, Specials.Payment For Painting Will Be Made Seperately ) ( S & P Schedule, Page-2 ) H ) ( Ii ) 80 Mm Dia. Medium Quality. 261 Supplying, Spreading And Consolidating Stone Dust To A Depth Of 100 Mm And Above At Desired Density And C.B.R. As Per Specification With Power Roller To Proper Gradient And Camber Including Watering As Necessary, And Lighting, Guarding, Barricading And Making Adequate Earthen Bundh Where Necessary To Protect The Edges And Curing With Water For 2 To 3 Days, Mending Cracks And Depressions By Rolling Where Necessary Including All Incidental Charges Of Roller, Cost Of Fuel & Lubricants Complete As Per Specification. ( Ref ; Pwd Sor 17 , Page No 242 , Item No 4.06 ) 262 Carriage Of Different Type Of Departmental Pipes From Divisional / Sub-Divisional Store To The Work Site By Truck Including Loading, Unloading, Stacking Etc. Including Cost Of Fuel, Lubricant And Also Cost Of Driver, Helper Etc. And All Other Taxes And Charges As Applicable As Per Direction Of Eicf ) Above 40 Km Upto 50 Km 263 G ) Above 50 Km ( Extra Cost Per Km ) Extra 50 Km ( 4 Nos Truck X 50 Km Each = 200 Km )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
15.
Housing Urban and Rular Development #10547255 Price Bid
M/T And Upgradation And Construction Sh Prepration Of Dpr And Cbr Tests Prepration Of Technical Sanction, Working Estimat, Dnit, And Structural Design Of Foundation, Sub Structure , Super Structure And Proof Checking Of Detailed Design And Structure Drawings Of 30 Mtr Psc Grider Bridge. , Prepration Of Detailed Project Report Which Include Following Provision As Mentioned Below: A) Topography Survey By Digital Total Station With Two Second Accuracy, Showing All Features On Survey Plan Like Trees, Culvert, Bridge, Electric Pole, Telephone Poles, Hand Pumps, School, Habitant Villages. B) Draw Cross Section At 15 M (Fifteen Meter) Interval, L-Section & Calculate The Quantity Of Earth Work In Standart Format Of Autocad Showing All Layer Of Pavement Components As Applicable. C) Prepration Of Survey Plan Showing All Provision And Preparation Of Detailed Project Report As Per Mord Guidelines. , Cbr Test Including Grain Size Analysis, Atterbergs Limit, Proctor Compaction And Cbr Value , Preparation Of Detailed Estimate Of Bridge As Per Analyised Rates.Printing Approved 3 Set And Submitting The Same To The Divisional Office. Same Aproved From Higher Office , Prepration Of Technical Sanction. The Work Will We Carried In Accordance With Latest Desgin Specfication, Latest Market Rate And To Satisfaction Of Engineer -In - Charge. Printing Two Set Complete In All Respect And Submitting The Same To Division Office And There After Approval From Competent Authority , Prepration Of Working Estimate. The Work Will We Carried In Accordance With Latest Desgin Specfication, Latest Market Rate And To Satisfaction Of Engineer -In - Charge.Printing Two Set Complete In All Respect And Submitting The Same To Division Office And There After Approval From Competent Authority , Prepration Of Dnit. The Work Will We Carried In Accordance With Latest Market Rate And To Satisfaction Of Engineer -In - Charge. Printing Two Set Complete In All Respect And Submitting The Same To Division Office And There After Approval From Competent , Structural Design Of Foundation, Sub Structure & Super Structure As Per Latest Design Codes And Preparation Of Working Drawings Of Foundation, Sub Structure & Super Structure. The Work Will We Carried In Accordance With Latest Design Specifications And To The Satisfaction Of Engineer-In-Charge , Proof Checking Of Detailed Design, Structural Drawings Of 30 Mtr Span Rcc T-Beam Bridge From Competent Authority Such As Iit,Nit Or Pec In All Respects And Submitting The Same To Higher Office For Approval.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Himachal Pradesh View Result →
16.
Health and Family Welfare #10546188 Price Bid
Ct Scanner 16 Slice With Flat Table Top Couch(Ct Simulator) Ct Scanner 16 Slice With Flat Table Top Couch(Ct Simulator) , Ct Scanner 16 Slice With Flat Table Top Couch As Per The Specification Except The Following , Additional Work Station , Dry Imager , Pressure Injector With Syringes , Full System Ups , Lead Glass , Light Weight Vinyl Lead Apron With Thyroid Shield , Gonad Shield , Music And Patient Address System With Speakers , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion):Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos /Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System (Cup Lock Type ) On The Exterior Side Of Building/Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, (2) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size). , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S (Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand)Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976/2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili/ Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977/2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978/2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979/2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer(Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980/2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C/C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms/Sqm (Both Side Inclusive), Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, ,Made Of G.I Sheet Having Galvanizing Of 100 Gms/ Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections (Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg/ Sq. Cm, Bending Strength 100 Kg/Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg/Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer (Fittings To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , 10.16.3 Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981/2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982/2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983/2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500/31000/40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I/C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878/2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf/Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf/ Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf/Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf/Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf/Cm2 , Od31984/2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized/Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness,Fixed To The Shutter Styles By Means Of Plastic/Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge( For W.C. And Bathroom Door Shutter). , Od31985/2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986/2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987/2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989/2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990/2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991/2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board /Any Other False Ceiling. The Rate Including All Labour Charges ,Material Charges Ect Complete. , Od33559/2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth(Bio-Active Fabric Washable Germfree-Suitable For Icu Room) Curtain System With Maximum Curtain Cloth Height 230Cm (Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval) Stitching With Stifiner Tape,Pleats,Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging/Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup ,All Leads And Lifts Including All Labour Charges Etc. Complete.(Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet)/Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length (App. Length 1.10M) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C/C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level ,Sealing All Gaps In False Ceiling Due To Hanging Supports ,All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560/2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored(30Mm) Lead(2Mm) Lined Flush Door Side Hung Two Rebated Shutters With Plywood(6Mm) & Laminated (1Mm) On Both Sides And All Accessories ( Ss Hinges (4 Nos), Tower Bolt , Ss Handles Etc..) , Lead Lined Door Frames: Lead(2Mm) Lined Flush Door Side Hung Single Shutter With Plywood(6Mm) &Laminated (1Mm) On Both Sides And All Accessories(Lead Sheet Should Overlap Door Frame & Wall )Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood /Jack Wood (Frame Size 12 Cm X 8 Cm) , Wood Frame For Fixing Lead Glass (Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard (Godrej) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled (Looped) Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor,Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module (200Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module (125Mmx125mm) , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers/ Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300/305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va/C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way (8+18) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8 + 18) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface/ Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/ Rccb/Isolator)2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, (Three Phaseand Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35/36 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 70 Sq. Mm (38Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 95 Sq. Mm (45Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 185 Sq. Mm (57Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 240 Sq. Mm (62Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm (25Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm (35Mm) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.65 Mm Copper Conductor (12 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm (12 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm (10 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm (8 Swg) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/ Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required (For Horizontal Run) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/ Terminating With Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W (Max), 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required (Philips, Wipro Or Similar Superior Make) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes (Make: M/S Almonard/ Crompton/Bajaj Or Equivalent) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan/ Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable (Size As Per The Requirement Of Ac Manufacturer) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit(Powder Coated) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw/Hr With Rotary/Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw/Hr With Rotary /Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables/Wires(Havells/Rr Kabel/V-Guard Frls Wires) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg/Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts/Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning (Sitc) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required , Supply And Providing Copper Earth Bus In The Panel Board , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos %Icu= 25Ka) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Suitable De- Humidifier Units : Extraction At Least 35 Litres/Day, Compresor : Rotary, Air Flow : At Least 220M3/Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Buy Back Offer Of Old Ct Simulator Available At Mch Kohikode , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp Digital Multifunction Meter To Read V,A.Hz,Pf,Kwh Surge Protection Device (Type1+2) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply, Installation, Testing And Commissioning (Sitc) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required (Not Taken For Evaluation) , Ct Fluoroscopy (Not Taken For Evaluation) , Branded Personal Computer With Printer (Not Taken For Evaluation) , Led View Box 3 Film (Not Taken For Evaluation) , Apple Osrix Workstation (Not Taken For Evaluation) , Neuro Package Including Neuro Dsa & Neuro Perfusion (Not Taken For Evaluation) , Spectral Package Including Twin Spiral Spectral Viewing, Dual Energy And Calculi Characterization (Not Taken For Evaluation)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
18.
Road Transport and Highways #10466563 Price Bid
Supervision Consultancy Services ( Sc ) For Supervision Of Operation And Maintenance Including Supervision Of Completion Of Balance Work Of Timmapuram To Losari Section ( 5 Packages ) Of Nh-216 { I.E., From Km 26+150 To Km 135+740 Of Nh-214 ( New Nh-216 ) And I.E., From Km 0+000 To Km 34+230 Of Nh-214A ( New Nh-216 ) } To 2 Lane With Paved Shoulder In The State Of Andhra Pradesh On Epc Basis. 1 Remuneration For Local Staff 2 Team Leader Cum Senior Highway Engineer 3 Resident Cum Highway Engineer 4 Bridge / Structural Engineer 5 Road Safety Expert 6 Sub-Professional Staff 7 Quantity Surveyor -1 8 Assistant Highway Engineer -1 9 Assistant Bridge Engineer-1 10 Assistant Quality Cum Material Engineer 11 Support Staff ( Inclusive Of Per Diem Allowance ) 12 Office Manager Cum Accountant 13 Computer Operator Cum Steno 14 Office Boy 15 Transportation ( Fixed Costs ) Scorpio / Bolero Or Equivalent ( Not More Than 03-Year-Old ) ( 01 Nos During Maintenance Period ) 16 Transportation ( Fixed Costs ) Toyota Etios Or Equivalent ( Not More Than 03-Year-Old ) ( 01 Nos During Maintenance Period ) 17 Office Rent ( Fixed Costs ) The Rent Cost Includes Electricity And Water Charges, Maintenance, Cleaning, Repairs, Etc. ( Rate Per Month ) During Maintenance / Dlp Period 18 Office Supplies Including Everything Such As Utilities, Drafting Supplies, Computer Running Cost Etc. ( Fixed Costs ) , Rate Per Month 19 Office Furniture And Equipment ( Rental ) Office Furniture Shall Include Executive Tables, Chairs, Visitor Chairs, Steel Almirahs, Computer Furniture, Conference Table Etc. Office Equipment Shall Include As A Minimum Of Telephone ( 2 External & 10 Internal Lines ) , Photocopier ( 15Ppm, 12000 Copies Per Month With A3 & A4 Input ) Fax Machine, Pcs ( 5 No., Intel Core 2 Duo E8300, 19’’ Colour Tft, Cache-6Mb, Ram-2 Gb, Hdd-250 Gb, Dvd Writer, Key Board, Optical Scroll Mouse, Ms- Windows Vista Business, Pre-Loaded Anti-Virus Etc. ) , Laser Printers ( 2 No., 14 Ppm, 266 Mhz, 5000 Pages Per Month, 600X600 Dpi Or Better Etc., Engineering Plan Printer ( 1 No. ) , Binding Machine ( 1 No. ) , Plotter A0 Size, Overhead Projector, Ac ( 4 No., 1.5 Ton ) , Water Coolers ( As Required ) Etc., 20 Reports And Document Printing ( Rate As Per Copy ) Monthly Reports 21 Road Survey Equipment, Rate Per Km 22 Surface Defects Detection And Roughness Measurement Using Network Survey Vehicle 23 Pavement Strength Measurement Using Fwd 24 Bridge Inspection Using Mobile Bridge Inspection Unit 25 Road Signs Inspection Using Retro Reflectometer 26 Contigenciesa Fixed Amount Of Indian Rupees One Million Shall Be Included In The Financial Proposal. ( Fixed As Rs. 10, 00, 000 ) And To Be Entered By Bidder
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Andhra Pradesh View Result →
19.
Health and Family Welfare #10416328 Price Bid
Tender For supply of Ct Simulator , 4D Ct Simulator As Per The Specification Except The Following , One Set Of 3 External Static Laser System , Laser Qa Tool , Laser Printer Duplex A4 , Laser Printer Duplex A3 , Single Head Pressure Injector With 100 Syringes , Water Bath / Oven , Full System Ups , Lead Apron With Thyriod Gurad , Lead Glove , Gonad Shield , Additional Workstation As Per Spec (Not Taken For Evaluation) , Dry Imager (Not Taken For Evaluation) , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion):Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos /Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System (Cup Lock Type ) On The Exterior Side Of Building/Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, (2) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size). , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S (Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand)Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976/2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili/ Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977/2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978/2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979/2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer(Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980/2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C/C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms/Sqm (Both Side Inclusive), Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, ,Made Of G.I Sheet Having Galvanizing Of 100 Gms/ Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections (Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg/ Sq. Cm, Bending Strength 100 Kg/Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg/Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer (Fittings To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , 10.16.3 Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981/2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982/2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983/2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500/31000/40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I/C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878/2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf/Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf/ Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf/Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf/Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf/Cm2 , Od31984/2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized/Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness,Fixed To The Shutter Styles By Means Of Plastic/Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge( For W.C. And Bathroom Door Shutter). , Od31985/2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986/2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987/2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989/2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990/2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991/2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board /Any Other False Ceiling. The Rate Including All Labour Charges ,Material Charges Ect Complete. , Od33559/2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth(Bio-Active Fabric Washable Germfree-Suitable For Icu Room) Curtain System With Maximum Curtain Cloth Height 230Cm (Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval) Stitching With Stifiner Tape,Pleats,Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging/Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup ,All Leads And Lifts Including All Labour Charges Etc. Complete.(Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet)/Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length (App. Length 1.10M) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C/C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level ,Sealing All Gaps In False Ceiling Due To Hanging Supports ,All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560/2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored(30Mm) Lead(2Mm) Lined Flush Door Side Hung Two Rebated Shutters With Plywood(6Mm) & Laminated (1Mm) On Both Sides And All Accessories ( Ss Hinges (4 Nos), Tower Bolt , Ss Handles Etc..) , Lead Lined Door Frames: Lead(2Mm) Lined Flush Door Side Hung Single Shutter With Plywood(6Mm) &Laminated (1Mm) On Both Sides And All Accessories(Lead Sheet Should Overlap Door Frame & Wall )Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood /Jack Wood (Frame Size 12 Cm X 8 Cm) , Wood Frame For Fixing Lead Glass (Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard (Godrej) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled (Looped) Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor,Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module (200Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module (125Mmx125mm) , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers/ Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300/305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va/C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way (8+18) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8 + 18) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface/ Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/ Rccb/Isolator)2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, (Three Phaseand Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35/36 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 70 Sq. Mm (38Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 95 Sq. Mm (45Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 185 Sq. Mm (57Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 240 Sq. Mm (62Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm (25Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm (35Mm) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.65 Mm Copper Conductor (12 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm (12 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm (10 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm (8 Swg) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/ Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required (For Horizontal Run) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/ Terminating With Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W (Max), 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required (Philips, Wipro Or Similar Superior Make) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes (Make: M/S Almonard/ Crompton/Bajaj Or Equivalent) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan/ Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable (Size As Per The Requirement Of Ac Manufacturer) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit(Powder Coated) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw/Hr With Rotary/Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw/Hr With Rotary /Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables/Wires(Havells/Rr Kabel/V-Guard Frls Wires) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg/Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts/Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning (Sitc) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required , Supply And Providing Copper Earth Bus In The Panel Board , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos %Icu= 25Ka) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Suitable De- Humidifier Units : Extraction At Least 35 Litres/Day, Compresor : Rotary, Air Flow : At Least 220M3/Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp Digital Multifunction Meter To Read V,A.Hz,Pf,Kwh Surge Protection Device (Type1+2) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply, Installation, Testing And Commissioning (Sitc) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required (Not Taken For Evaluation)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
20.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
21.
Housing Urban and Rular Development #10373373 Price Bid
Tender For Strengthening Of Road (Construction Of Rotary And Other Development Works Around Rotary On 45M Wide Road Along Sector-90 And 137) Noida, 1 Demolishing cement concrete manually/ mechanical means and incluiding disposal of material within 50 metres lead as per direction of Engineer-in-charge. Normal 1:3:6 or richer Mix. 2 Demolishing R.C.C work manually/ by mechanical means incluiding stacking of steel bars and disposal of unserviceable materials within 50 metre lead as per direction of Engineer - in-charge. 3 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m,and lift upto1.5m, as directed by Engineer-in-charge. : All kinds of soil. (C.R.) The Contractor has to detect Different utilities like sewer line, water Supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of Engineer-in- Charge(CR). 4 Filling available excavated earth (excluiding rock) in trenches, plinth , sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering , lead up to 50m and lift upto 1.5m 5 Disposal of building rubbish / malba / similar unserviceable , dismantled or waste materials by mechanical means incluiding loading transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge. Beyound 50 m initial lead, for all leads incluiding all lifts involved. 6 Construction of sub-grade and earthen shoulder with approved obtained from right of way all lifts & leads , transporting to site ,spreading ,grading to required slope and compacted to meet requirement of table no. 300-2 7 By Mix in Place Method Well graded Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. MORT&H Specification 401 Sr No 4.1 8 Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 9 Prime Coat over WBm/WMM, Providing and applying Primewith SS1 grade bitumen emulsion using emulsion pressure distributor at the rate of 0.70 to 1.00 kg per sqm using mechanical means. 10 (Dense Graded Bituminous Macadam Grading 2 )Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 per centby weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as percomplete in all respects. 11 Providing and applying tack coat using hot straight run bitumen of grade VG-10 incluiding heating the bitumen, sraying the bitumen with mechanically operated spray uint fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : On bituminous surface @ 0.50 kg/sqm. 12 Bituminous Concrete Grading 2 Providing and laying bituminous concrete withhigher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4per centof mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per complete in all respects 13 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface.Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 The finished surface to be level, uniform and free from streaks and holes. 14 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -all work upto plinth level 1:4:8(1cement :4 course sand (zone III ):8 graded stone aggregate 40mm nominal size ). 15 Providing and laying factory made chamferededge Cement Concrete Paver Blocks in Footpath, parks, lawns, drive ways, or light traffic parking etc, of required strenght, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand , compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra san. complete all as per direction of Engineer-in-charge.16.91.1 60mm thick c.c. paver block of M-35 grade with approved color and design & pattern. 16 Centering and shuttering including strutting, propping etc. and removal of form for :Wall any thickness including attached pilasters, buttresses, plinth and string course etc. 17 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete 18 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 19 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impaining strength and durability as per direction of the Engineer-in-charge. (Note Cement content considered in this item is @ 330kg/cum.Excess/less cement used as per design mix is payable/recoverable separately). All works up to plinth level. 20 Extra for providing richer mixes at all floor levels. Noe :- Excess/less cement over the specified content used is payable/recoverable separately . Providing M-30 grade concrete inseed of M-25 grade BMC/RMC. ( Note:- Cement content considered in M-30 is @340 kg/cum). 21 Manufacturing, Supplying and fixing retro reflective overhead signage boardmade up of 2mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens tyoe heat activatedretro reflective sheeting conforming to type- III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC :67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substratre by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by..........complete as per drawings, specification and direction of the engineer-in-charge ( structural frame workincluding M.S plate to be provided separately. Rectangular area of the sheet only shall be measured for payment)Full Language in orignal file. 22 Providing wall putty on new surface with approved quality material of Berger/JK/Birla of similar make 2 coats 23 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 24 Providing and laying Mastic Wearing course ( as per specifications ) with Industrial bitumen of grade 85/25 conforming to IS : 702, prepared by using mastic cooker and laid to required level and slope, Incluiding providing antiskid surface with bitumen precoated fine grainedhard stone chipping of approved size at the rate of 0.005 cum per 10 sqm and at approximate spacing of 10 cm centre to centre in both directions, pressed into surface protruding 1 mm to 4mm over mastic surface, Incluiding cleaning the surface, removal of debris etc. All complete. ( Considering bitumen using 10.2% as per MORTH specification ) 40mm thick 25 Brick work with common burnt clayF .P.S (non modular ) bricks of class designation 100 in foundation and plinth in : cement mortar 1:4 ( 1 cement : 4 coarse sand ) 26 Providing and laying C.C pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per Engineer- in -charge. (The panel shuttering work shall be paid for separately.) ( Note:- Cement content considered in this item is @330 Kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). 27 Fabrication & Manufacturing of Prestressed Hollow Core slab (Hollow area 25 to 30%) of different thickness & modular width 1200 mm in Controlled Factory Environment with approved methodology confirming to IS 10297:1982 by using long line casting method having arrangement ............as per the direction of the Engineer-in-charge. (Cost of strands should be paid separately). Note: Excess/less cement over the specified cement content used as per design mix is payable/recoverable separately) including steel & Transport charge.Full Language in Orignal file. 28 Boring/drilling bore well of required dia for casing /strainer pipe, by suitable method prescribed in IS : 2800 (part I), incluiding collecting samples from different strata, preparing and submitting strata chart/ bore log, incluiding hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.1 All types of soil23.1.1.1300 mm dia. 29 Supplying , assembling, lowering and fixing in verticle position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, incluiding required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.3.3 200 mm dia. 30 Supplying , Filling , spreading & Leveling stone Boulders of size range 5cm to 20cm , in Recharge Pit , in the required thickness, for all leads & lift , all complete as per direction of Engineer-in-charge. 31 Supplying , Filling , spreading & Leveling Gravels of size range 5mm to 10mm , in the Recharge Pit , over the existing layer of boulders, in required thickness, for all leads & lift , all complete as per direction of Engineer-in-charge. 32 Supplying , Filling , spreading & Leveling Coarse sand of size range 1.5 mm to 2 mm , in the Recharge Pit , over the gravel layer , in required thickness, for all leads & lift , all complete as per direction of Engineer-in-charge. 33 Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800(part 1). 34 centering and shuttering incliuding strutting propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. 35 Providing and fixing plan non- asbestos cement sheet strip in joints pavement / terrazo flooring 100mm wide & 6mm thick (based on item no. 11.13.1/195/DAR-2018 vol-1 36 Taking out existing CC interlocking paver blocks from footpath/ central verge, incluiding removal of rubbish etc, disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-charge. 37 Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe grade @ maximum 100mm c/c on both ways, neat cement punning on finished surface, propoerly encased on all edges with 1.6 mm thick, 100 mm wide MS sheet duly painted over primimg coat, reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc I/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. 38 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. incluiding cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, incluiding welding and bolted with special shaped washers Electric resistance or induction bult welded tubes etc complete. 39 Steel work welded in built up sections/ framed work, incluiding cutting ,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 41 12mm Cement plaster of mix : 1:4 (1 cement :4 course sand) 42 Sculpture at rotary.(White marble modern art.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 10
Uttar Pradesh View Result →
22.
Housing Urban and Rular Development #10373368 Price Bid
Tender For Development Of Sector-117 (Construction Of Drain Between Sector-120, 117 And Sarfabad), Noida, 1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.The Contractor has to dectect different utilities like sewer line, water supply line, electric cable, telephone cable , gas pipe line etc, using utility decteting machine before start of excavation andshall start excavation only after getting permission of E/I. All kind of soil (Letter No. Noida/CPE/2015/464, Dt. 20.07.2015) 2 Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : bituminous road 3 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) 5 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 6 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level 7 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 8 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete 9 Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 10 Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform 11 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mm nominal size) 12 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter 13 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 14 Providing wall putty on new Surface with Approved Quality Material of Berger/ J.K / Birla or Similar Make 2 Coats. 15 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 10
Uttar Pradesh View Result →
23.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
24.
Health and Family Welfare #10350693 Price Bid
Tender For supply of Mri Simulator , Mr Simulator As Per The Specification Except The Following , Mr-Rt Planning , Additional Workstation , Mr Compatible Pressure Injector With Syringes , Full System Ups , Dry Imager , Iv Stand ( Mr Compatible ) , Patient Trolley ( Mr Compatible ) , Music And Pa System With Speakers , Patient Comfort Kit As Per Spec , Hand Held Metal Detector , Metal Detector Door , Wheel Chair ( Mr Compatible ) , Fire Extinguisher Mr Compatible , Mr Compatible Stethoscope , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) :Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System ( Cup Lock Type ) On The Exterior Side Of Building / Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1 ) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, ( 2 ) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size ) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S ( Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand ) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand ) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand ) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976 / 2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili / Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portionpowder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977 / 2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978 / 2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979 / 2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm ) , With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980 / 2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C / C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms / Sqm ( Both Side Inclusive ) , Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, , Made Of G.I Sheet Having Galvanizing Of 100 Gms / Sqm ( Both Sides Inclusive ) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns ( Minimum ) , Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg / Sq. Cm, Bending Strength 100 Kg / Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc ( Noise Reduction Coefficient ) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg / Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer ( Fittings To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc ( Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) , 10.16.3 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981 / 2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982 / 2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983 / 2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500 / 31000 / 40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I / C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878 / 2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf / Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf / Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf / Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf / Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf / Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf / Cm2 , Od31984 / 2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized / Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness, Fixed To The Shutter Styles By Means Of Plastic / Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge ( For W.C. And Bathroom Door Shutter ) . , Od31985 / 2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986 / 2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987 / 2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989 / 2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990 / 2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991 / 2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board / Any Other False Ceiling. The Rate Including All Labour Charges , Material Charges Ect Complete. , Od33559 / 2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth ( Bio-Active Fabric Washable Germfree-Suitable For Icu Room ) Curtain System With Maximum Curtain Cloth Height 230Cm ( Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval ) Stitching With Stifiner Tape, Pleats, Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging / Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup , All Leads And Lifts Including All Labour Charges Etc. Complete. ( Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet ) / Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length ( App. Length 1.10M ) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C / C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level , Sealing All Gaps In False Ceiling Due To Hanging Supports , All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560 / 2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Providing, Making And Fixing In Position Partition Walls Over A Wooden Frame Work Of Size 50X50mm With Hard Wood Pinkoda / Violet / Or Equivalent Frame Work At 60Cm Or Nearest As Verticals And Three Numbers Of Horizontals, Spacing As Shown In The Drawing With 10Mm / 12Mm Thick Marine Plywood On Onesides Of The Frame Work For The Fullheight Of Height And Fixing Plywood With Teak Wood Beadings Between Plywood And Wooden Frame With Suitable Junction Joints And Extra Supports If Needed For Joinery Openings.The Plywood Is Fixed To The Frame Work Using Steel Screws Including Finishing The Joints With Joint Filler Etc.To Get Smooth And Even Finished Joints Including Cost And Labour Charges Of All Materials And The Outer Frames Fixing To Concrete / Masonry By Chipping And Providing Tight Plugs, Making Good The Damages, Including Cost Of All Materials Such As All Wooden Members, Plywood On Onesides, Etc. Complete, Wooden Sections Confirming To The Nearest Dimensions Etc.For Fixed Partitions Etc Complete As In The Drawing And As Per Requirement. The Rate Inclusive Of All Material Charge, Labour, Transportation, Scaffolding ( If Needed ) Loading / Unloading At The Work Spaceetc. Complete As Per The Direction Of Engineer In Charge. , Wood Frame For Fixing Lead Glass ( Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard ( Godrej ) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module ( 100Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module ( 200Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module ( 125Mmx125mm ) , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers / Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300 / 305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va / C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way ( 8+12 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way ( 8+18 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way ( 8 + 18 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface / Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phaseand Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35 / 36 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%, , Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1 / 2X 70 Sq. Mm ( 38Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 95 Sq. Mm ( 45Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 185 Sq. Mm ( 57Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 240 Sq. Mm ( 62Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm ( 25Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm ( 35Mm ) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.65 Mm Copper Conductor ( 12 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm ( 12 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm ( 10 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm ( 8 Swg ) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal / Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall / Parapet / Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required ( For Horizontal Run ) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg ) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16 / 0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W ( Max ) , 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required ( Philips, Wipro Or Similar Superior Make ) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes ( Make: M / S Almonard / Crompton / Bajaj Or Equivalent ) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan / Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable ( Size As Per The Requirement Of Ac Manufacturer ) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit ( Powder Coated ) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables / Wires ( Havells / Rr Kabel / V-Guard Frls Wires ) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg / Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts / Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply And Providing Copper Earth Bus In The Panel Board , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A / 400A, 50 / 55 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Suitable De- Humidifier Units : Extraction At Least 35 Litres / Day, Compresor : Rotary, Air Flow : At Least 220M3 / Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Supply, Installation, Testing And Commissioning ( Sitc ) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp Digital Multifunction Meter To Read V, A.Hz, Pf, Kwh Surge Protection Device ( Type1+2 ) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Additional Iron Shielding If Any , Mr Compatible Pipe For Medical Gas 12Mm , Mr Compatible Outlet , Mr Compatible Flowmeter With Humidifier , Mr Compatible Wall Mounted Suction Jar , Mr Compatible Probes , Mr Compatible Bed Head Panels For 6 Outlets , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. ( Not Taken For Evaluation ) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos %Icu= 25Ka ) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. ( Not Taken For Evaluation ) , Supply, Installation, Testing And Commissioning ( Sitc ) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required. ( Not For Evaluation ) , Small Fov Diffusion Like Focus, Zoomit, Zoom Diffusion ( Not Taken For Evaluation ) , Breast Spectroscopy Like Brease, Grace, Breast Spectro. ( Not Taken For Evaluation ) , Cartilage Assessment Like Cartigram, Mapit, Cartilage Assessment. ( Not Taken For Evaluation ) , Free Breathing Abdominal Imaging Like Ideal / Freezit ( Not Taken For Evaluation ) , Liver Imaging Package With Iron Quantification Like Ideal Iq / Liverlab Etc. ( Not Taken For Evaluation ) , Bone Imaging. ( Not Taken For Evaluation ) , Oncology Support Assembly For Head / Neck, Flex Coils For Neuro, Body & Pelvic Imaging. ( Not Taken For Evaluation )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
25.
Health and Family Welfare #10350409 Price Bid
Tender For supply of Digital Pet Ct Scanner As Per The Specification Except The Following , Advanced Dedicated Work Station For Pet-Ct With Oncology, Cardiology & Neurology Packages , Dual Head Injector , Dry Laser Imager , Full System Ups , Lead Glass , Additional Workstation With 1 Tb Storage Capacity , Dose Calibrator For Pet , Portable Survey Meter For Pet , Contamination Monitor For Pet , Personal Pocket Dosimeter , Tungsten Vial Shield For Carrying Isotopes , Syringe Shields For 2 & 5 Ml , Shielded Waste Decay Drum For Pet Radionuclide , L Bench With Lead Glass For Pet , Lead Lined Storage Cabinet , Interlocking Lead Bricks Including Corner Blocks , Shield Lead Carrier For Pet Doses , Light Weight Vinyl Lead Apron Of 0.5Mm Lead Equivalent , Foot Operayive Waste Bin For Pet , Dose Calibrator Shileding Ring For Pet , Dose Dispensing Unit , Decontamination Kit , Tongs 12, 18 And 24 Inch , Transport Container (Biodex Or Equivalent) , Cushioned Sofa Seats , Icu Trolley , Water Purifier (Hot And Cold) , Televisions 42 , Office Table , Dining Table With 10 Chair , Rubco Chairs , Modular Book Shelf With Glass Doors , Library Chair , Library Table , Jefferson Chair , Projector And Screen , Sound System With Fixed Mic And Wireless Mic , Pharma Refrigerator 400L , Induction Cooker , Non Revolving Chair , Refrigerator 260L , Emergency Trolley , External Lasers , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 15.60 Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 2.31Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 5.2.2Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , 50.5.33.1Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M- 20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note: Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Up To Plinth Level , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size). , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.1Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Foundations, Footings, Bases Of Columns, Etc For Mass Concrete , 5.9.2Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion):Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos /Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System (Cup Lock Type ) On The Exterior Side Of Building/Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, (2) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S (Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand)Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete , Providing And Fixing Gi Chicken Wire Mesh 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes Including Cement Slurry And Pegs/Nails With Nailing Machine As Required Before Plastering Etc. Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) , 13.12- 18 Mm Cement Plaster In Two Coats Under Layer 12 Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand )And A Top Layer 6 Mm Thick Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand) Finished Rough With Sponge. , 22.5Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B) Second Layer Of Slurry Of Cement @ 0.242 Kg /Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976/2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili/ Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977/2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978/2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979/2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer(Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980/2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C/C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms/Sqm (Both Side Inclusive), Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, ,Made Of G.I Sheet Having Galvanizing Of 100 Gms/ Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections (Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg/ Sq. Cm, Bending Strength 100 Kg/Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg/Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer (Fittings To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , 10.16.3 Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981/2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982/2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983/2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500/31000/40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I/C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.81Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand/Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P/S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878/2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf/Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf/ Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf/Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf/Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf/Cm2 , 18.7.2 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge. Internal Work - Exposed On Wall20 Mm Nominal Outer Dia Pipes , 18.7.3Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge. Internal Work - Exposed On Wall 25 Mm Nominal Outer Dia Pipes , 18.8.2Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20 Mm Nominal Outer Dia Pipes , 18.8.3 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 25 Mm Nominal Outer Dia Pipes , Od31984/2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized/Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness,Fixed To The Shutter Styles By Means Of Plastic/Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge( For W.C. And Bathroom Door Shutter). , Od31985/2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986/2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987/2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989/2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990/2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991/2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board /Any Other False Ceiling. The Rate Including All Labour Charges ,Material Charges Ect Complete. , Od33559/2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth(Bio-Active Fabric Washable Germfree-Suitable For Icu Room) Curtain System With Maximum Curtain Cloth Height 230Cm (Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval) Stitching With Stifiner Tape,Pleats,Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging/Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup ,All Leads And Lifts Including All Labour Charges Etc. Complete.(Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet)/Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length (App. Length 1.10M) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C/C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level ,Sealing All Gaps In False Ceiling Due To Hanging Supports ,All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560/2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored(30Mm) Lead(2Mm) Lined Flush Door Side Hung Two Rebated Shutters With Plywood(6Mm) & Laminated (1Mm) On Both Sides And All Accessories ( Ss Hinges (4 Nos), Tower Bolt , Ss Handles Etc..) , Lead Lined Door Frames: Lead(2Mm) Lined Flush Door Side Hung Single Shutter With Plywood(6Mm) &Laminated (1Mm) On Both Sides And All Accessories(Lead Sheet Should Overlap Door Frame & Wall )Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood /Jack Wood (Frame Size 12 Cm X 8 Cm) , Wood Frame For Fixing Lead Glass (Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard (Godrej) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Group Controlled (Looped) Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 4 Sq. Mmm , Switches & Sockets: Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15/16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 20/25 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 20/25 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module (200Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module (125Mmx125mm) , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Ceiling, Wall And Exhaust Fans: Extra For Fixing The Louvers/ Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes (Make: M/S Almonard/ Crompton/Bajaj Or Equivalent) , Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With 16/0.20Mm Pvc Insulated And Pvc Sheathed 650/1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mm Sweep -5Star Rated Bldc Ceiling Fan Complete With 300Mm Down Rod , Canopies, Shackles And Blades Working On 230V/240V Single Phase A/C , Supply Of 300/305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va/C , Db Mcb Switch Gear: Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8+18) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8 + 18) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface/ Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/ Rccb/Isolator)2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, (Three Phaseand Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required 100 Amp, 30 Ka 4 Pole , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35/36 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Cable Supply Laying And Termination: Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc.As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 300 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required. 3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 70 Sq. Mm (38Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 95 Sq. Mm (45Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 185 Sq. Mm (57Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 240 Sq. Mm (62Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 10 Sq. Mm (25Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 16 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 50 Sq. Mm (35Mm) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 10 Sqmm , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Earthing & La: Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 2.65 Mm Copper Conductor (12 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 3.15 Mm Copper Conductor ( 10 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 4.00 Mm Copper Conductor ( 8 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 2.65 Mm (12 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm (10 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm (8 Swg) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/ Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required (For Horizontal Run) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads 40Mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/ Terminating With Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 2.00 Mm Copper Conductor ( 14 Swg) , Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube,Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Fixing Of Lightning Conductor Finial (Single Prong) With Base Plate Including Holes Etc. Complete As Required , Jointing Copper / G.I. Tape (With Another Copper/ G I Tape, Base Of The Finial Or Any Other Metallic Object) By Riveting / Nut Bolting/ Sweating And Soldering Etc As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Vertical Run) , Fixing Of Copper/ G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Horizontal Run) , Fixing Of Copper/ G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. , Providing And Laying G.L. Tape 32 Mm X 6 Mm From Earth. Electrode Directly In Ground As Required , Laying Copper/ G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Led Fixtures S&F: Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Supplying And Fixing Of Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W (Max), 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Supplying And Fixing Ofrecess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required (Philips, Wipro Or Similar Superior Make) , Supply Of 18W Led Downlighter With A Nominal System Lumen Output Of Minimu 500 Lumens. System Wattage Should Not Exceed 18W. The Luminaire Shall Have A Rated System Lifetime Of 50,000 Burning Hours. The Luminaire Should Have A Color Temperature Of 5700K And Cri>80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.95. Housing Shall Be Crca Powder Coated With Pmma Diffuser.Driver Shall Have 85% Efficiency. Similar To Wipro Make Ld06-221-Xxx-57-Xxor Eqivalent , Supply Of 12W Led Downlight, High Efficiency With A Nominal System Lumen Output Of 760 Lumens. Luminaire Wattage Should Not Exceed 12W. The Luminaire Should Have Acri > 80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.9. Slim Led Batten In Aluminium Housing And Decorative End Caps. Robust Driver With Wide Voltage Range 100-240 Volts And Inbuilt Protection. Aesthetically Designed Mirror Led Light Fixture Of 4000 K,Of Surface Mounting Which Provides Soft-Light And Glare Free Symmetrical Illumination. Simialr To Model Number Ld07- 131-060-40-Wh Of Wipro Make Or Equivalent. , Fire Alarm, Fire Extinguisher & Safety: Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Supplying, Installing, Testing And Commissioning Ofconventionalsingle Action Manual Call Point , Supplying, Installing, Testing And Commissioning Of Conventional Hooter With Builtin Flasher Lightwith Base Ul/En Listed. , Supplying, Installing, Testing And Commissioning Of 2 Core X 1.5 Sqmm Fr Pvc,Multistrand Copper Cu Ar Cable Confirming To Is Standards And Specifications. Make: Polycab / Century , Providing Installating, Connecting, Testing And Commissioning Heat Detectors Type With Mounting Base, Blinking Ledas Required Complete And Integration , Supplying, Installation, Testing And Commissioning Ofconventional Photoelectric Smoke Detectorsas Required To Connect With Existing System , Providing And Fixing Of Response Indicator As Required , Conventional Single -Zone Fire Panel With Batteries, Battery Charger Mimic Diagram Etc , Supply And Providing2/3 Mm Thick Sythetic Type And 1 M Wide Electrical Grade Chequered Type Rubber Mat To Withstand 3.3 Kv Dielectric Strength Conforming To Is 5429/1969. , Supply And Providing Laminated First Aid Chart Duly Framed And Placed In A Conspicuous Location For Clear Vision. , Numbering & Lettering: Numbering Of Ceiling Fan / Exhaust Fan/ Fluorescent Fittings As Required. , Hvac Works: Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable (Size As Per The Requirement Of Ac Manufacturer) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit(Powder Coated) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw/Hr With Rotary/Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw/Hr With Rotary /Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables/Wires(Havells/Rr Kabel/V-Guard Frls Wires) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg/Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts/Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning (Sitc) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required , Suitable De- Humidifier Units : Extraction At Least 35 Litres/Day, Compresor : Rotary, Air Flow : At Least 220M3/Hr, Reputed Brand, Input 230V Ac , Ssb And Ups Panel:Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos %Icu= 25Ka) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Statutory Approvals: Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , Elv: Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor,Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 32Mm , Supplying And Laying Of Following Pair Armoured Telephone Cable Through Wall/Tray With All Acessories As Required For Complete Installation And As Instructed By Engineer In Charge/Consultant And Making Good All Damages Made For Installation. 5 Pair , Kronebox-Supply,Erection,Testingandcommissioningoffollowingpairkronewithbox Including Mounting Frame, Enclosure Of Isi Grade With Lockable Front Cover With All Accessories Required For For Complete Installation In Wall As Directed By The Engineer In Charge. 10Pair , Supply, Installation, Testing And Commissioning Of Basic User Phone With Necessary Connection As Required For Complete Installation As Directed By The Engineer In Charge. , Supplying And Drawing Of 6 Core Sm Armoured Optical Fibre Cable (Ofc) Through Wall / Tray With All Acessories As Required For Complete Installation And As Instructed By Engineer In Charge / Consultant And Making Good All Damages Made For Installation. , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required 1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Drawn Of Utp 4 Pair Cat 6A Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required 1 Run Of Cable , Cat 6A Rj 45 Computer Jack Modular Socket Outlet , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 9U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Dismantling Works : Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Cctv & Public Addressing System: Supply, Installation, Testing And Commissioning Of Ip Based 3.6 Mm Fixed Lens, 2Mp Resolution, H.264 / H.265, 1/2.8 Progressive Scan Cmos Day/Night, Ir Dome Poe Enabled Camera,20 To 30 Meters Ir Range, 120 Db Digital Wdr With All Connectors And Necessary Accessories For Mounting In False Ceiling As Required For Complete Installation As Directed By Engineer In Charge. , Ceiling Mounted Speaker - Supply, Fixing, Testing And Commissioning Of Ceiling Mount Metal Grille Speakers With Inbuilt Line Matching Transformer With Power 6W With All Accessories Required For Complete Instllation As Required. , Wall Mounted Speaker - Supply, Fixing, Testing And Commissioning Of Wall Mounted Speakers With Inbuilt Line Matching Transformer With Power 9Wwith A Volume Controller To Adjust The Volume Individually As Per The Requirement With All Accessories Including Wall Mounting Kit Required For Complete Instllation. The Volume Controller Shall Be Fixed Separately As Per The Site Condition For Individual Control. Cost Inclusive Of Necessary Interconnection Including Conduit, Connection Wire Etc , Mechanical Ventillation System: Axial Fans: Supply, Installation, Testing And Commissioning Direct Driven Axial Flow Fans Suitable Formountingonwallorductinstandardgalvanized/Powdercoatedsteelconstructionwith Requiredrating,Static,Singlemotorandflexibleconnectiontoconnectwithducting/Plenum, Louvers With Birdscreen. The Cost Inclusive Of Ducts Required As Per The Layout. 50 - 250 Cfm , Supply, Installation, Testing And Commissioning (Sitc) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp Digital Multifunction Meter To Read V,A.Hz,Pf,Kwh Surge Protection Device (Type1+2) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
26.
Housing Urban and Rular Development #10295873 Price Bid
Tender For D/O Village (C/O Kitchen Toilet And Safety Tank In Primary School Of Nalgarha Village Dallupura For Opreation Of Kayakalp) Noida - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. The contractor has to detect diffrent utilities like sewar line ,Water supply line ,Electric cable,Telephone cable, Gas pipe line etc. using utility detecting machine before start of excavation and shallstart excavation only after getting permission of engineer in charge All kinds of soil. 2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (Zone-III) drived from natural sources : 8 graded stone aggregate 40 mm nominal size drived from natural sources). 3 Brick work with Common Brunt clay F.P.S( Non-modular) bricks of class designation 100 in foundation and plinth in:Cement mortar 1:4 (1 cement :4 coarse sand) 4 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330kg/cum.Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level 5 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330kg/cum.Excess/less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level 6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 7 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 Kms, from the site of work and including watering, dressing etc. labour and T&P etc. required for the proper complition of the work. saplings of girth upto 30 cms. measured at a height of 1 M. above ground level and removal of rubbish upto a distance of 50 M. out side the periphery of area cleared. 8 Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns, etc. for mass concrete. 9 Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. 10 Centering and shuttering including strutting, propping etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. 11 Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts. 12 Brick work with F.P.S. bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes inCement mortar 1:4 (1 cement :4 coarse sand) 13 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 14 6 mm cement plaster of mix:1:3 (1 cement: 3 fine sand) 15 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs C) After two days of proper curing applying a second coat of cement slurry using 2.75kg! sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre doth of approved quality in top layer of plaster and finally finishing the surface with trowe’ with neat cement suvr an making pattern ot 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge:With average thickness of 120mm and minimum thickness at khurra as 65 mm. 16 Providing Wall putty on new surface with approved qualit material of Berger/ J.K. / Birla or similar make 2 coats. 17 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shadeNew work (two or more coats) over and including water thinable priming coat with cement primer. 18 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.110 mm diameter 19 Providing and fixing on wall face uriplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10 mm gap for thermal expansion.Bend 87.5°110mm bend 20 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 5Ox5Ox5Omm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the waIl etc. complete.110 mm 21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard designIn 75x75mm deep chase 22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet lmxlmx400micron, finished with 12mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete. 23 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 24 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 25 Earth Work in Embankment in ordinary soil embankment to be in 20cm layers including ramming Dressing the surface to required levels with half tonne steel or wooden rammer and rolling every third and top most layer in roller 8 to 10 tonne capacity and Including 1.50mtr, Lift and all lead(earth shall be brought from a placewhich including cartage of earth by mechanically transport and T & P. Labour etc.required for proper completion.Earth shall be arranged by the contractor at his own cost. 26 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 27 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand(Zone-III) drived from natural sources : 4 graded stone aggregate 20 mm nominal size drived from natural sources) 28 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 29 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 30 Kota stone slab 20 mm thick in risers of step, skiting, dado nd pillars laid on 12mm (average) thick cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete Sand Stone Flooring 31 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm 32 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chainwith rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: White glazed fire clay kitchen sink of size 600x450x 250 mm 33 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semirigid pipe 40 mm dia 34 P/F PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long. Wt. not less than 88 gms. 35 Providing and fixing PTMT stop cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not lessthan 88 gms 36 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length 37 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal outer dia Pipes 38 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 39 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suttable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 40 Providing and fixing water closet squatting pan (Indian type W.C. pan with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern includly flush pipe with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever requiredWhite Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. 41 Providing and fixing white vitreous china pedestal type water closet (European type ) with seat and lid, 10 litre low level white vitreous china flushing cistern & C P flush bend with fittings & C I brackets. 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved muncipal design complete , including painting 0f fittingas and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid 42 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern 43 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China wash basin size 550x 400 mm with a pair of 15 mm C.P. brass pillar tap 44 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal outer dia Pipes 45 Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms 46 P/F PTMT Ball cock of approved quality colour and make-complete with Epoxy coated- with L.P./ H.P.H.D. plastic ball. 15 mm nominal bore, 105 mm long. Wt. not less than 138 gms. 47 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 48 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways ,or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paverlocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand compated all as per direcation of engineer -in - charge .60mm thick Cement concrete paver block of M-35 grade with approved colour, design & pattern.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Uttar Pradesh View Result →
27.
Housing Urban and Rular Development #10270510 Price Bid
Tender For Construction Of Ad Office Udhampur- 1 Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : 2 Removal / disposal of surplus excavation earth by mechanical means upto a lead of 1km. 3 Providing and lying in position cement concreteof specified gradeexcluding the cost of centring and shuttering- all works upto plinth level. (crushedStone 40 mm nominal size) 1 cement 4 coarse sand: 8 graded, stone aggregates 40mm size crushed Stone. 4 Providing and laying Cement Concrete (1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size) in string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level etc. l, including curing but excluding the cost of centring, shutteringand finishing with. 5 Providing and laying in position specified grade of reinforced cement concrete M 20 Mix excluding the cost of centering, shuttering, finishing and reinforcement - All works upto plinth level:1:1:5:3 (1 cement: 1:5 coarse sand:3 graded stone aggregate 20mm nominal size) 6 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts ans sturts, etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size) 7 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 8 Providing and laying in position cement concrete of 1:3:6 grade (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) excluding the cost of centring andshuttering- All work upto plinth level. 9 Brickworkwith common burnt clay F.P.S (non modualar) bricks of class designation 75 upto plinth level in 1cement : 4 fine sand mortar. 10 Providing and laying damp-proof course 50 mm thick with cement concrete 1: 2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 nominal size) crushed aggregate 11 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 12 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. 13 Cetring and shuttering including strutting, propping etc and removal of the form work for: 14 Foundation, footing, bases of columns 15 Wall (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 16 Suspended floors, roofs, landing, balconies and access platforms. 17 columns, Pillars,Piers, Abutments, Posts and Struts. 18 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 19 Edge of slabs and break in floors and walls Under 20 cms wide. 20 Weather shade, chajjas, corcels etc., including edes. 21 Stairs, (excluding landings) except spiral staircases 22 Brickworkwith common burnt clay F.P.S (non modualar) bricks of class designation 75 in superstructureupto floor V level in 1cement : 6 fine sand mortar. 23 Half brick masonry with bricks of class designation 75 in foundations and plinth, and superstructure upto floor V level in Cement mortar 1:4 (1 cement: 4 coarse sand). 24 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m. 25 Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete. 26 15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 coarse sand) 27 Add for plaster drip course/groove in plastered surface of moulding to R.C.C. projections. 28 Making of Grove 12mm x10 mm between Brick and RCC. 29 Providing and laying vitrified floor tiles in Size of tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete 30 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 31 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.In colour such as White, Ivory, Grey, Fume Red Brown 32 Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab over 0.5 sqm) 18mm thick:- 33 Extra for providing edge moulding to 18 mm thick Granite stone counters, Vanities etc. over item no. 8.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 34 Extra for providing opening of required size and shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble I stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. 35 Cement concrete flooring 1:2:4 ( 1 cement: 2 coarse sand 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.50 mmthick with 20mm nominal size stone aggregate. 36 Providing and fixing on wall face unplasticized - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.110 mm diameter 37 Providing and fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised- Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 1 0 mm gap for thermal expansion. 38 Coupler 110mm. 39 Single tee with door 110 x 110 x110mm 40 Bend 87.5* 110mm 41 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggreagate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 42 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Sal wood 43 Providing 40x5 mm flat iron hold fast 40 em long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 44 Providing and fixing 35mm thickglazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. in Second Class Deodar Wood 45 Providing and fixing 35mm thick wire guage shutters using galvanised M.S. wire guage of average width for aperture 1.4 mm in both direction with wire of dia 0.63 mm for doors, windows and clerestory windows with ISI marked M.S pressed but hinges bright finished butt hinges of required size with necessary screws, in Second Class Deodar Wood 46 Providing and fixing Glass panes weighing 13.75 kg/sqm with Deodar wood Fillets.(Area of opening for glass panes excluding portion inside rebate shall be measured). 47 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1stclass hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. 49 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 50 Providing and fixing stainless steel tower bolt ISI marked of approved make with necessary screws etc. complete : 51 200x10 mm 52 150x10 mm 53 Providing and fixing stainless steel Aldrops ISI marked of approved make with necessary screws etc. complete :250X14 mm 54 Providing and fixing stainless steel Handles ISI marked of approved make with necessary screws etc. complete : 55 150 mm 56 100 mm 57 Providing and fixing stainless steel hanging floor door stopper lSI markedwith necessary crews etc. complete .Twin rubber stopper. 58 Providing and fixing stainless steel M.S. hasp and staple (Safety type) lSI marked with necessary screws etc. complete. 59 Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete : 60 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary ccessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 61 providing and fixing of stainless steel nevel post including top ball of aisi 304 grade of required height duli anchored to floor with dash fasteners . Height of the nevel post shall not be less than 1050mm above the finished squirting level all complete as per architectural drawing (including cost of material lead,lift,carriage at etc. 62 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete. 63 Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Two or more coats applied @ 1.25 liter/10sqm over andincluding one coat of special primer applied @ 0.75liter /10sqm 64 Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). 65 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work ( wood work). 66 Providing and fixing of overhead signage boards made up of 2 mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type-II of STM-D-4956-01 as approved by engineer in charge, letters, boarders etc. at entrance over pillars including Aluminium frame work 67 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 68 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. 69 Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. 70 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40mm C.P. brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the walls wherever required : Size 600x450x200 mm 71 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 literwhite P.V.C automatic flushing cistern. 72 Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects as per direction of Engineer-Incharge. 73 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 74 Providing & fixing C.P. brass robe hook fixed to wall/door with plastic rawl plugs andC.P brass screws including cutting and making good the walls wherever required as per direction of Engineer-Incharge. 75 Providing & fixing recessed liquid soap dispenseras per direction of Engineer-Incharge. 76 P/F of Soap Dish Holder with all fittings as per direction of Engineer-in-charge 77 Providing and fixing of Tumbler Holder with all fittings as per direction of Engineer-in-charge 78 Providing and fixing Bottle Trap and other ancillary fittings. Cutting and making good the walls wherever required compete as per directions of Engineer-Incharge. 79 Providing and fixing 6mm copper backed float glass mirror MODI / SAINT-GOBAIN including 6mm thick BWR type ply board, 40mm stainless steel channel plugged to wall, hard wood treated with two coats of wood preservative, etc. all complete as specified and to the satisfaction of Engineer in charge. 80 Providing and fixing CP brass towel rail of approved make complete with CP brackets fixed to wooden cleats with CP brass screws. 81 Providing and fixing 15 mm dia. C.P. brassbib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (Short Body) 82 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 83 Providing and fixingPVC pipes 6kg/cm2 pressure excluding pvc fittings, jointing with adhesive/seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion of approved make Supreme/Finolex/ Astral or equilant. 84 110 mm dia 85 80 mm dia 86 160 mm dia 87 Providing and fixingPVC plain Bend of approved make Supreme/Finolex/ Astral or equilant complete. 88 110 mm dia 89 160 mm dia 90 Providing and fixingPVC Floor Trap of approved make Supreme/Finolex/ Astral or equilant complete. 91 110 mm X 80 mm 92 160 mm X 110 mm 93 Providing and fixingPVC Plain Tee of approved make Supreme/Finolex/ Astral or equilant complete. 94 110 mm X 80 mm 95 Providing and fixingPVC Door Bend of approved make Supreme/Finolex/ Astral or equilant complete. 96 110 mm 97 Providing and fixingPVC Door Tee of approved make Supreme/Finolex/ Astral or equilant complete. 98 110 mm 99 Providing and fixingPVC Coupler of approved make Supreme/Finolex/ Astral or equilant complete. 100 160 mm 101 Providing and fixingPVC Clamps for pvc pipes of approved make complete. 102 110 mm 103 Providing and fixingPVC Cowl of approved make complete. 104 110 mm 105 Providing and fixingC.P Jali of approved make complete. 106 110 mm 107 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Sintex, Electroplast, star, Lotous or equivalent having valid ISI license) (2000 ltr. Capacity 3 No.). 108 Cutting holes upto 30x30 cm in walls including making good the same with common burnt clay F.P.S.(non modular) bricks 109 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 110 32 mm Diameter 111 25 mm Diameter 112 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 113 Group C 114 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 115 2x1.5 +1 1x1.5 sq. mm 116 2 x 2.5 + 1x2.5sq. mm 117 2 x 4.0 +1x4.0 sq. mm 118 2 X 6.0 +1x6.0 sq. mm 119 2 x 10.0 + 1x6.0 sq. mm 120 4 x 6 sq.mm +2 X 6 sq.mm earth wire 121 4 X 10 sq.mm +2 X 6 sq.mm earth wire 122 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 123 20mm Conduit 124 25mm Conduit 125 40mm Conduit 126 deep junction box 127 surface junction box 128 5” dia fan box 129 Supplying and fixing following size/modules , GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 130 1 or 2 module ( 75mm x 75mm) 131 3 Module (100mmX75mm) 132 4 Module ( 125mm x 75mm) 133 6 Module ( 200mm x 75mm) 134 8 Module ( 125mm x 125mm) 135 12 Module ( 200mm x 150mm) 136 Supplying and fixingon exisitng GI Box modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc as required. 137 Supplying and fixingon exisitng GI Box modular plate and cover in front on surface or in recess, including providing and fixing 5 pin5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc as required. 138 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 139 5/6Amp Switch 140 3 pin 5/6 Amp socket outlet 141 Telephone socket outlet 142 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc., as required. 143 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 144 Installation, Testing and commissioning of pre-wired, fluorescent fitting of all types complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5sqmm FRLS PVC insulated , copper conductor, single core cable and earthing etc. as required. 145 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 146 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 147 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 148 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 149 2 Pair 150 4 Pair 151 Supplying and drawing of UTP 4 pairCAT 6A LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 152 Supplying and fixing 5 amps to 32 amps 10kArating, 240 Volts, C series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 153 Single pole 154 Single pole & Neutral 155 Trip pole & Neutral 156 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 157 Providing and fixing M.V. danger notice plate of 200mm x 150mm , made of mild steel, at least 2 mm thick , and viterous enamelled white on both sides, and with inscription in single red colour on front side as required. 158 Supply, Installation, Testing and commissioning of following Distribution boards made of sheet steel in IP43construction with key lock with sheet metal door of Legrand(Ekinoxe3) or equivalent in Siemens/Schneider makes 159 8 Way TPN 160 6 Way TPN 161 Supply of following LED lighting fixtures 162 Supply of Wall / Ceiling Fans230V 50Hz celing fan with double ball bearing with low power consumptionof following sweeps: 163 1200mmCeiling Fan 164 400mm Wall Fan 165 Supply of following sizes of heavy duty exhaust fan as per approved makes 166 450mm Sweep 167 200mm Sweep 168 Supply of 1.1kV grade , XLPE insulated,Aluminium conductor, Heavy Duty , Armoured cables of following ratings as per IS : 7098 Part-1 with latest amendments. 169 3.5C x 400sqmm 170 3.5C x 120sqmm 171 3.5C x 70sqmm 172 Supplying and Installing Following Size of Perforated Hot Dipped Galvanized Cable Tray with Perforation not more than 17.5% in convenient Sections ,joined with connectors ,suspended from the Ceiling including bolts and Nuts ,etc as required. 173 300mm (W) x 50 mm (H)x 1.6 mm(T)cable tray Perforated type 174 Providingandfixing FireExtinguishers(A,B,Ctype powder)complete withallaccessories as per manufacturers specifications. 175 Supply, installation, testing and commissioning of 75 mm Cu. Pipe Filled with Crystalline conductive Mixture with Copper Strip of Size 40 mm x 6 mm of Length2 mtr with Ecofriendly Backfill Compound 50 Kg. Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance value & Earth pit chamber (300mm x 300mm) with CI cover for the above as required complete Job. 176 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 177 Supplying,Installation,Testing and Commissioning of CubicalTypeLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars, etc. as required as per the Following Description.INCOMERi) MCCB 400 Amps 4 P with Breaking Capacity 36 KA(1 Nos)ii) Indicating Lamps RYB(1 Set) iii) Voltmeter-0-500 Volts &Ammeter (0-600 A) (1 No Each) iv)Selector Switch (2 Nos)&Current Transformer 500/5 A 10 VABurdenClass-1 v) Aluminium Busbar 600 Amps FP E-91 E Grade Electrolytic Aluminiumvi) Digital Load Manager ,SP MCB 2 A& ON/OFFTRIP (02 Sets) 178 OUTGOINGSi) MCB 100 Amps TPN C curv (36 Nos) ii) MCCB 100 Amps 4 P with Breaking Capacity 25 KA (1 Nos) v)Load Bearing Members to be made out of 2.0 mm CRCA Sheet. vi)Partitions to be made out of 1.6 mm CRCA Sheet & Gland Plates to be 3.0 mm Thick. 179 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thickcompacted bed of fine sand, filling the joints with coarse sand etc. allcomplete as per direction of Engineer-in-charge. 180 Carriage of material by M.T inclloading/unloading& stacking complete 181 Sand av lead 54 km 182 Stone agg below 40 mm nominal size av lead 5 km 183 Bricks av lead 75 km
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
28.
Health and Family Welfare #10267207 Price Bid
Cardiac Cath Lab With Ep Facility Model A , Cathlab Machine As Per The Specification Except The Following , Medical Grade Large High Definition Fhd Display 55 , Four Medical Grade High Definition Display Lcd / Led Flat 19 Or Higher Monitors With Wide Viewing Angle, High Luminance High Contrast, Flicker Free, Distortion Free , Electrophysiology Application , Workstation As Per Spec , High Pressure Injector With 200 Syringes , Online Ups For Cathlab & Accessories , Console, Workstation, Lights And Computer , All In One Computer With Laser Printer , 12 Channel Ecg With Pc Connectivity , Full Wrap Around Lead Aprons , Skirt ( With Fastening Belt ) -Vest Type Lead Aprons , Front Fulltype Lead Apron , Light Weight Leadless Single Piece Aprons With Front And Back Coverage , Light Weight Leadless Skirt And Vest With Fastening Belt , Thyroid Guard Lead Less , Leadless Head Gear Radiation Protection And Light Weight Lead Goggles , Lead Stockings , Lead Spectacles , Lead Gloves , Heavy Duty Stand With Hangers To Hold Atleast 5 Lead Aprons ( Stainless Steel 304 Construction ) , Wall Mounted Hangers To Hold Atleast 5Lead Aprons , Intercom Between Exam And Control Room , Instrument Table , Accessory Table , Buy Back Offer Of Existing Cathlab Model Philips Allua Fd10 Installed At Mch Kottayam , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) :Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System ( Cup Lock Type ) On The Exterior Side Of Building / Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1 ) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, ( 2 ) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size ) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S ( Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand ) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand ) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand ) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976 / 2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili / Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portionpowder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977 / 2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978 / 2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979 / 2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm ) , With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980 / 2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C / C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms / Sqm ( Both Side Inclusive ) , Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, , Made Of G.I Sheet Having Galvanizing Of 100 Gms / Sqm ( Both Sides Inclusive ) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns ( Minimum ) , Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg / Sq. Cm, Bending Strength 100 Kg / Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc ( Noise Reduction Coefficient ) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg / Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer ( Fittings To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc ( Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) , 10.16.3 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981 / 2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982 / 2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983 / 2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500 / 31000 / 40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I / C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878 / 2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf / Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf / Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf / Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf / Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf / Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf / Cm2 , Od31984 / 2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized / Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness, Fixed To The Shutter Styles By Means Of Plastic / Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge ( For W.C. And Bathroom Door Shutter ) . , Od31985 / 2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986 / 2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987 / 2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989 / 2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990 / 2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991 / 2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board / Any Other False Ceiling. The Rate Including All Labour Charges , Material Charges Ect Complete. , Od33559 / 2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth ( Bio-Active Fabric Washable Germfree-Suitable For Icu Room ) Curtain System With Maximum Curtain Cloth Height 230Cm ( Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval ) Stitching With Stifiner Tape, Pleats, Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging / Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup , All Leads And Lifts Including All Labour Charges Etc. Complete. ( Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet ) / Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length ( App. Length 1.10M ) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C / C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level , Sealing All Gaps In False Ceiling Due To Hanging Supports , All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560 / 2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored ( 30Mm ) Lead ( 2Mm ) Lined Flush Door Side Hung Two Rebated Shutters With Plywood ( 6Mm ) & Laminated ( 1Mm ) On Both Sides And All Accessories ( Ss Hinges ( 4 Nos ) , Tower Bolt , Ss Handles Etc.. ) , Lead Lined Door Frames: Lead ( 2Mm ) Lined Flush Door Side Hung Single Shutter With Plywood ( 6Mm ) &Laminated ( 1Mm ) On Both Sides And All Accessories ( Lead Sheet Should Overlap Door Frame & Wall ) Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood / Jack Wood ( Frame Size 12 Cm X 8 Cm ) , Wood Frame For Fixing Lead Glass ( Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard ( Godrej ) For Storage 6Ft Tall 3 Feet Width , Cupboardfor Storage Of Catheters , 6Ft Tall 3 Feet Width.19 Mm Ply Board Construction Laminate Finishpainted ( Enamel ) As Per Approval. Front Panels To Have A Locking Arrangements With One Panel Having Tower Bolt On The Inner Sidewith Handles , Magnetic Hinges Andall Complete , Providing, Fixing And Installation Of Floor Mounted 2 Bay Scrub Station Made Of Ss 304 1.6Mm Thk. Sheet Withtimeout Facilities, Foot Operated With Hot And Cold Water Mixture Complete With All Fittings Etc. Satin Finish And Most Optimal Ra Value. Elbow Operated Water And Hand Scrub. Curved Joints To Avoid Microbial Deposition And Growth, Ensuring Perfect Hygiene And Ease Of Cleaning. The Station Shall Be Equipped With Soap Dispensers. Easily Openable For Refilling The Hand Scrub / Routine Maintenance. Two Bay 63”X29”44” , Catheter Hanger And Wall Clamp Ss304 For 5 Aprons Including All Materials And Fittings , Lead Apron Hanger. Completely Made Of Ss304. Provision To Hang 10 Aprons. The Hanger Should Be 2Ft Width. Shoould Have Strong Base For Stability. The Width Of The Total Assembly Shall Be 3.5Ft Width And 2 Ft Depth. The Height Shall Be 153 Ft. , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module ( 100Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module ( 200Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module ( 125Mmx125mm ) , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers / Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300 / 305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va / C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way ( 8+12 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way ( 8+18 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way ( 8 + 18 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface / Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phaseand Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35 / 36 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%, , Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1 / 2X 70 Sq. Mm ( 38Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 95 Sq. Mm ( 45Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 185 Sq. Mm ( 57Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 240 Sq. Mm ( 62Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm ( 25Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm ( 35Mm ) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.65 Mm Copper Conductor ( 12 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm ( 12 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm ( 10 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm ( 8 Swg ) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal / Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall / Parapet / Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required ( For Horizontal Run ) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg ) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16 / 0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W ( Max ) , 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required ( Philips, Wipro Or Similar Superior Make ) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes ( Make: M / S Almonard / Crompton / Bajaj Or Equivalent ) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan / Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable ( Size As Per The Requirement Of Ac Manufacturer ) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit ( Powder Coated ) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables / Wires ( Havells / Rr Kabel / V-Guard Frls Wires ) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg / Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts / Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning ( Sitc ) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required , Supply And Providing Copper Earth Bus In The Panel Board , Cardiac Catheter Wash Station : Completely Made Ofss 304 Gsatin Finish, All Curved Joints Should Be As Perhtm Standards To Ensureperfect Hygiene And Ease Of Cleaning, Provision Forconnecting The Catheter Using 3 Way Adapter, Provision To Connect Air ( High Pressure ) And Water Through Separate Discharge Pipe Lines To Clean The Catheter, Wall Mounted Type, Approximate Dimension 33”Lx 24”W X 57”H, Provisions To Connect And Clean At Least 6 Catheters Simultaneously. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp Digital Multifunction Meter To Read V, A.Hz, Pf, Kwh Surge Protection Device ( Type1+2 ) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A / 400A, 50 / 55 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Suitable De- Humidifier Units : Extraction At Least 35 Litres / Day, Compresor : Rotary, Air Flow : At Least 220M3 / Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. ( Nottaken For Evaluation ) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos %Icu= 25Ka ) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. ( Not Taken For Evaluation ) , Supply, Installation, Testing And Commissioning ( Sitc ) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required ( Not Taken For Evaluation ) , The Scrub Station Shall Be Made Of High-Grade Stainless Steel 304 With Stain Polish Finish And Wired To The Current Iee Regulations & Bs 7971. The Scrub Stations Control System Shall Be Based On Advanced Microprocessor. The Scrub Station Shall Be Sensor-Activated 24Vac. The Scrub Station Shall Be Provided With User Selectable Time Out Control. The Supply Shall Not Be Interrupted In Case Of Power Failure Or Maintenance. The Station Shall Be Equipped With Thermostatic Mixing Valve To Controls The Temperature Of Hot / Cold Water Supply. The Washing Faucet Shall Be Made Of Chrome Plated Brass Hand. The Station Shall Be Equipped With Soap Dispensers. Two Bay 63”X24”31” ( Not Taken For Evaluation ) , Eto Sterlizer, Sealing Machine & Accessories ( Not Taken For Evaluation ) , Latest Dose Reduction / Image Quality Improvement Packageslike Autoright / Clarity / Optiq. ( Not Taken For Evaluation ) , Cathlab Machine As Per Specifications With 18 Inches Or 46Cms Diagnol Detector Except Monitors ( All Configuration As Per Sr No 13 Except Detector ) ( Not Taken For Evaluation ) , Iabp As Per The Specification ( Not Taken For Evaluation )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
29.
Health and Family Welfare #10267202 Price Bid
Supply of Cardiac Cath Lab With Ep Facility Model B , Cathlab Machine As Per The Specification Except The Following , Medical Grade Large High Definition Fhd Display 55 , Four Medical Grade High Definition Display Lcd / Led Flat 19 Or Higher Monitors With Wide Viewing Angle, High Luminance High Contrast, Flicker Free, Distortion Free , Electrophysiology Application , Workstation As Per Spec , High Pressure Injector With 200 Syringes , Online Ups For Cathlab & Accessories , Console, Workstation, Lights And Computer , All In One Computer With Laser Printer , 12 Channel Ecg With Pc Connectivity , Full Wrap Around Lead Aprons , Skirt ( With Fastening Belt ) -Vest Type Lead Aprons , Front Fulltype Lead Apron , Light Weight Leadless Single Piece Aprons With Front And Back Coverage , Light Weight Leadless Skirt And Vest With Fastening Belt , Thyroid Guard Lead Less , Leadless Head Gear Radiation Protection And Light Weight Lead Goggles , Lead Stockings , Lead Spectacles , Lead Gloves , Heavy Duty Stand With Hangers To Hold Atleast 5 Lead Aprons ( Stainless Steel 304 Construction ) , Wall Mounted Hangers To Hold Atleast 5Lead Aprons , Intercom Between Exam And Control Room , Instrument Table , Accessory Table , Buy Back Offer Of Existing Cathlab Model Philips Allua Fd10 Installed At Mch Kottayam , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) :Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System ( Cup Lock Type ) On The Exterior Side Of Building / Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1 ) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, ( 2 ) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size ) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S ( Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand ) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand ) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand ) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976 / 2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili / Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portionpowder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977 / 2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978 / 2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979 / 2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm ) , With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980 / 2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C / C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms / Sqm ( Both Side Inclusive ) , Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, , Made Of G.I Sheet Having Galvanizing Of 100 Gms / Sqm ( Both Sides Inclusive ) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns ( Minimum ) , Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg / Sq. Cm, Bending Strength 100 Kg / Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc ( Noise Reduction Coefficient ) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg / Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer ( Fittings To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc ( Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) , 10.16.3 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981 / 2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982 / 2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983 / 2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500 / 31000 / 40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I / C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878 / 2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf / Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf / Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf / Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf / Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf / Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf / Cm2 , Od31984 / 2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized / Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness, Fixed To The Shutter Styles By Means Of Plastic / Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge ( For W.C. And Bathroom Door Shutter ) . , Od31985 / 2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986 / 2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987 / 2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989 / 2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990 / 2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991 / 2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board / Any Other False Ceiling. The Rate Including All Labour Charges , Material Charges Ect Complete. , Od33559 / 2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth ( Bio-Active Fabric Washable Germfree-Suitable For Icu Room ) Curtain System With Maximum Curtain Cloth Height 230Cm ( Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval ) Stitching With Stifiner Tape, Pleats, Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging / Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup , All Leads And Lifts Including All Labour Charges Etc. Complete. ( Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet ) / Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length ( App. Length 1.10M ) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C / C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level , Sealing All Gaps In False Ceiling Due To Hanging Supports , All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560 / 2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored ( 30Mm ) Lead ( 2Mm ) Lined Flush Door Side Hung Two Rebated Shutters With Plywood ( 6Mm ) & Laminated ( 1Mm ) On Both Sides And All Accessories ( Ss Hinges ( 4 Nos ) , Tower Bolt , Ss Handles Etc.. ) , Lead Lined Door Frames: Lead ( 2Mm ) Lined Flush Door Side Hung Single Shutter With Plywood ( 6Mm ) &Laminated ( 1Mm ) On Both Sides And All Accessories ( Lead Sheet Should Overlap Door Frame & Wall ) Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood / Jack Wood ( Frame Size 12 Cm X 8 Cm ) , Wood Frame For Fixing Lead Glass ( Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard ( Godrej ) For Storage 6Ft Tall 3 Feet Width , Cupboardfor Storage Of Catheters , 6Ft Tall 3 Feet Width.19 Mm Ply Board Construction Laminate Finishpainted ( Enamel ) As Per Approval. Front Panels To Have A Locking Arrangements With One Panel Having Tower Bolt On The Inner Sidewith Handles , Magnetic Hinges Andall Complete , Providing, Fixing And Installation Of Floor Mounted 2 Bay Scrub Station Made Of Ss 304 1.6Mm Thk. Sheet Withtimeout Facilities, Foot Operated With Hot And Cold Water Mixture Complete With All Fittings Etc. Satin Finish And Most Optimal Ra Value. Elbow Operated Water And Hand Scrub. Curved Joints To Avoid Microbial Deposition And Growth, Ensuring Perfect Hygiene And Ease Of Cleaning. The Station Shall Be Equipped With Soap Dispensers. Easily Openable For Refilling The Hand Scrub / Routine Maintenance. Two Bay 63”X29”44” , Catheter Hanger And Wall Clamp Ss304 For 5 Aprons Including All Materials And Fittings , Lead Apron Hanger. Completely Made Of Ss304. Provision To Hang 10 Aprons. The Hanger Should Be 2Ft Width. Shoould Have Strong Base For Stability. The Width Of The Total Assembly Shall Be 3.5Ft Width And 2 Ft Depth. The Height Shall Be 153 Ft. , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module ( 100Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module ( 200Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module ( 125Mmx125mm ) , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers / Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300 / 305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va / C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way ( 8+12 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way ( 8+18 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way ( 8 + 18 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface / Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phaseand Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35 / 36 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%, , Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1 / 2X 70 Sq. Mm ( 38Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 95 Sq. Mm ( 45Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 185 Sq. Mm ( 57Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 240 Sq. Mm ( 62Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm ( 25Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm ( 35Mm ) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.65 Mm Copper Conductor ( 12 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm ( 12 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm ( 10 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm ( 8 Swg ) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal / Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall / Parapet / Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required ( For Horizontal Run ) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg ) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16 / 0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W ( Max ) , 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required ( Philips, Wipro Or Similar Superior Make ) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes ( Make: M / S Almonard / Crompton / Bajaj Or Equivalent ) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan / Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable ( Size As Per The Requirement Of Ac Manufacturer ) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit ( Powder Coated ) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables / Wires ( Havells / Rr Kabel / V-Guard Frls Wires ) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg / Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts / Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning ( Sitc ) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required , Supply And Providing Copper Earth Bus In The Panel Board , Cardiac Catheter Wash Station : Completely Made Ofss 304 Gsatin Finish, All Curved Joints Should Be As Perhtm Standards To Ensureperfect Hygiene And Ease Of Cleaning, Provision Forconnecting The Catheter Using 3 Way Adapter, Provision To Connect Air ( High Pressure ) And Water Through Separate Discharge Pipe Lines To Clean The Catheter, Wall Mounted Type, Approximate Dimension 33”Lx 24”W X 57”H, Provisions To Connect And Clean At Least 6 Catheters Simultaneously. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp Digital Multifunction Meter To Read V, A.Hz, Pf, Kwh Surge Protection Device ( Type1+2 ) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A / 400A, 50 / 55 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Suitable De- Humidifier Units : Extraction At Least 35 Litres / Day, Compresor : Rotary, Air Flow : At Least 220M3 / Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. ( Nottaken For Evaluation ) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos %Icu= 25Ka ) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. ( Not Taken For Evaluation ) , Supply, Installation, Testing And Commissioning ( Sitc ) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required ( Not Taken For Evaluation ) , The Scrub Station Shall Be Made Of High-Grade Stainless Steel 304 With Stain Polish Finish And Wired To The Current Iee Regulations & Bs 7971. The Scrub Stations Control System Shall Be Based On Advanced Microprocessor. The Scrub Station Shall Be Sensor-Activated 24Vac. The Scrub Station Shall Be Provided With User Selectable Time Out Control. The Supply Shall Not Be Interrupted In Case Of Power Failure Or Maintenance. The Station Shall Be Equipped With Thermostatic Mixing Valve To Controls The Temperature Of Hot / Cold Water Supply. The Washing Faucet Shall Be Made Of Chrome Plated Brass Hand. The Station Shall Be Equipped With Soap Dispensers. Two Bay 63”X24”31” ( Not Taken For Evaluation ) , Eto Sterlizer, Sealing Machine & Accessories ( Not Taken For Evaluation ) , Latest Dose Reduction / Image Quality Improvement Packageslike Autoright / Clarity / Optiq. ( Not Taken For Evaluation ) , Cathlab Machine As Per Specifications With 18 Inches Or 46Cms Diagnol Detector Except Monitors ( All Configuration As Per Sr No 13 Except Detector ) ( Not Taken For Evaluation ) , Iabp As Per The Specification ( Not Taken For Evaluation )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
30.
Power #10237421 Price Bid
Tender For Different Work Under The Area Of Uedd-Ii, Varanasi Under Add. Business Plan 2023-24- 1 For Replacement Of 33 Kv Varuna Garden And 33 Kv Nkvp Main Vcb At Chaukaghat S / S Varanasi Under Add. Business Plan 2023-24 2 Labour Charge 3 Replacement Of Old Vcb To New Vcb 4 Laying Of Control Cable 5 De-Centralised Item 6 Control Cable 4X2.5 Sqmm 7 For For Laying New U / G 11 Kv, 3X185 Sqmm Xlpe Cable From Sbi Bank To Badshahbag Tubewell Where Single Cable Is Available On 11 Kv Badshahbag Feeder, Varanasi Under Add. Business Plan 2023-24 8 Labour Charge 9 Cable Laying Charge Of 3X185 Sq.Mm Xlpe U / G Double Ckt By Digging / Drilling Method 10 Jointing Of 11 Kv, 3X185 Sq.Mm O / D Box And Connection With Associated Ht Line & Hoisting Of Cable On D / P And Jumpering 11 Cartage Of Cable & Other Materials From Central Store Rajatalb To Site Including Loading And Unloading 12 De-Centralised Item 13 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm O / D 14 Hdpe Pipe 160 Mm Suitable For Road Crossing 15 G I Pipe 100 Mm Dia Classb 16 Ms N&B Off Size With Washer 17 For Laying New U / G 11 Kv, 3X185 Sqmm Xlpe Cable From 250 Kva Dt St. Raghuwar Nagar To 100 Kva Dt Chandrika Nagar Where Single Cable Is Available On 11 Kv Bank Colony Feeder, Varanasi Under Add. Business Plan 2023-24 18 Labour Charge 19 Cable Laying Charge Of 3X185 Sq.Mm Xlpe U / G Double Ckt By Digging / Drilling Method 20 Jointing Of 11 Kv, 3X185 Sq.Mm O / D Box And Connection With Associated Ht Line & Hoisting Of Cable On D / P And Jumpering 21 Cartage Of Cable & Other Materials From Central Store Rajatalb To Site Including Loading And Unloading 22 De-Centralised Item 23 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm O / D 24 Hdpe Pipe 160 Mm Suitable For Road Crossing 25 G I Pipe 100 Mm Dia Classb 26 Ms N&B Off Size With Washer 27 For Laying New U / G 11 Kv, 3X185 Sqmm Xlpe Cable From 400 Kva Telwala T / F To 400 Kva Lavkush T / F Where Single Cable Is Available On 11 Kv Kali Mahal Feeder, Varanasi Under Add. Business Plan 2023-24 28 Labour Charge 29 Cable Laying Charge Of 3X185 Sq.Mm Xlpe U / G Double Ckt By Digging / Drilling Method 30 Jointing Of 11 Kv, 3X185 Sq.Mm O / D Box And Connection With Associated Ht Line & Hoisting Of Cable On D / P And Jumpering 31 Cartage Of Cable & Other Materials From Central Store Rajatalb To Site Including Loading And Unloading 32 De-Centralised Item 33 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm O / D 34 Hdpe Pipe 160 Mm Suitable For Road Crossing 35 G I Pipe 100 Mm Dia Classb 36 Ms N&B Off Size With Washer 37 For Laying New U / G 11 Kv, 3X185 Sqmm Xlpe Cable From Telephone Exchange To 400 Kva Telwala T / F Where Single Cable Is Available On 11 Kv Kali Mahal & 11 Kv Kodai Chauki Feeder, Varanasi Under Add. Business Plan 2023-24 38 Labour Charge 39 Cable Laying Charge Of 3X185 Sq.Mm Xlpe U / G Double Ckt By Digging / Drilling Method 40 Jointing Of 11 Kv, 3X185 Sq.Mm O / D Box And Connection With Associated Ht Line & Hoisting Of Cable On D / P And Jumpering 41 Jointing Of 11 Kv, 3X185 Sq.Mm S / T J / Kit 42 Erection Of Pole Including Its Grouting & Muffing 43 Painting Of Pole With Material 44 Earthing Of Pole With Earth Rod 45 Grouting Of Stay 46 Cartage Of Cable & Other Materials From Central Store Rajatalb To Site Including Loading And Unloading 47 De-Centralised Item 48 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm O / D 49 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm S / T 50 G I Pipe 100 Mm Dia Classb 51 Ms N&B Off Size With Washer 52 For Laying Of 11 Kv 3X185 Sqmm Cable From Ayurvedik Hospital To Chitrakoot Maidan Via Sampoornanand East Gate Of Nati Imali Feeder, Varanasi Under Add. Business Plan 2023-24 53 Labour Charge 54 Cable Laying Charge Of 3X185 Sq.Mm Xlpe U / G Double Ckt By Digging / Drilling Method 55 Jointing Of 11 Kv, 3X185 Sq.Mm O / D Box And Connection With Associated Ht Line & Hoisting Of Cable On D / P And Jumpering 56 Jointing Of 11 Kv, 3X185 Sq.Mm S / T J / Kit 57 Cartage Of Cable & Other Materials From Central Store Rajatalb To Site Including Loading And Unloading 58 De-Centralised Item 59 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm O / D 60 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm S / T 61 G I Pipe 100 Mm Dia Classb 62 Ms N&B Off Size With Washer 63 For Splitting Of 11 Kv Sonia Feeder ( Overloaded ) , Nagar Nigam S / S And Shifting The Load On Kali Mahal Feeder, Beniyabagh S / S, Varanasi Under Add. Business Plan 2023-24 64 Labour Charge 65 Cable Laying Charge Of 3X185 Sq.Mm Xlpe U / G Double Ckt By Digging / Drilling Method 66 Jointing Of 11 Kv, 3X185 Sq.Mm O / D Box And Connection With Associated Ht Line & Hoisting Of Cable On D / P And Jumpering 67 Jointing Of 11 Kv, 3X185 Sq.Mm S / T J / Kit 68 Erection Of Pole Including Its Grouting & Muffing 69 Painting Of Pole With Material 70 Earthing Of Pole With Earth Rod 71 Grouting Of Stay 72 Cartage Of Cable & Other Materials From Central Store Rajatalb To Site Including Loading And Unloading 73 De-Centralised Item 74 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm O / D 75 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm S / T 76 Hdpe Pipe 160 Mm Suitable For Road Crossing 77 G I Pipe 100 Mm Dia Classb 78 Ms N&B Off Size With Washer 79 For Laying New U / G 11 Kv, 3X185 Sqmm Xlpe Cable From Falmandi To Sonia Mod On 11 Kv Sonia Feeder, Varanasi Under Add. Business Plan 2023-24 80 Labour Charge 81 Cable Laying Charge Of 3X185 Sq.Mm Xlpe U / G Double Ckt By Digging / Drilling Method 82 Jointing Of 11 Kv, 3X185 Sq.Mm O / D Box And Connection With Associated Ht Line & Hoisting Of Cable On D / P And Jumpering 83 Cartage Of Cable & Other Materials From Central Store Rajatalb To Site Including Loading And Unloading 84 De-Centralised Item 85 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm O / D 86 Hdpe Pipe 160 Mm Suitable For Road Crossing 87 G I Pipe 100 Mm Dia Classb 88 Ms N&B Off Size With Washer 89 For For Laying New U / G 11 Kv, 3X185 Sqmm Xlpe Cable From Aurangabad Chauraha To Mini Tubewell Where Single Cable Is Available On 11 Kv Sonia Feeder, Varanasiunder Add. Business Plan 2023-24 90 Labour Charge 91 Cable Laying Charge Of 3X185 Sq.Mm Xlpe U / G Double Ckt By Digging / Drilling Method 92 Jointing Of 11 Kv, 3X185 Sq.Mm O / D Box And Connection With Associated Ht Line & Hoisting Of Cable On D / P And Jumpering 93 Cartage Of Cable & Other Materials From Central Store Rajatalb To Site Including Loading And Unloading 94 De-Centralised Item 95 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm O / D 96 Hdpe Pipe 160 Mm Suitable For Road Crossing 97 G I Pipe 100 Mm Dia Classb 98 Ms N&B Off Size With Washer 99 For Laying New U / G 11 Kv, 3X185 Sqmm Xlpe Cable From Mini Tubewell To Sarai Fatak Where Single Cable Is Available On 11 Kv Sonia Feeder, & Laying New U / G 11 Kv, 3X185 Sqmm Xlpe Cable From Aurangabad Chauraha To Kamlapati Tiwari Where Single Cable Is Available On 11 Kv Sonia Feeder Varanasi Under Add. Business Plan 2023-24 100 Labour Charge 101 Cable Laying Charge Of 3X185 Sq.Mm Xlpe U / G Double Ckt By Digging / Drilling Method 102 Jointing Of 11 Kv, 3X185 Sq.Mm O / D Box And Connection With Associated Ht Line & Hoisting Of Cable On D / P And Jumpering 103 Cartage Of Cable & Other Materials From Central Store Rajatalb To Site Including Loading And Unloading 104 De-Centralised Item 105 Cable Jointing Kit H&S, 11 Kv, 3X185 Sq.Mm O / D 106 Hdpe Pipe 160 Mm Suitable For Road Crossing 107 G I Pipe 100 Mm Dia Classb 108 Ms N&B Off Size With Washer
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
31.
Drinking Water Supply and Sanitation #10236715 Price Bid
Augmentation Cum Reorganization Of Aapni Yojana Phase I Churu Bisau Feeder Water Supply Project Including 10 Years O And M District Churu.- 1 Part A : Cost Estimate For Pipeline Works 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 75 Mm Dia 4 90 Mm Dia 5 110 Mm Dia 6 125 Mm Dia 7 140 Mm Dia 8 160 Mm Dia 9 180 Mm Dia 10 200 Mm Dia 11 225 Mm Dia 12 100 Mm Dia 13 150 Mm Dia 14 200 Mm Dia 15 250 Mm Dia 16 300 Mm Dia 17 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-7 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 18 100 Mm Dia 19 150 Mm Dia 20 200 Mm Dia 21 250 Mm Dia 22 300 Mm Dia 23 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-9 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 24 150 Mm Dia 25 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpe Pe- 80 Pn-6 Isi Marked Pipes As Per Is-4984:1995 ( Ammended Upto Date ) With Neccessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe By Butt Fusion / Electro Fusion Welding Method, Including All Taxes, Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bends Etc. ) , Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earthwork ) 26 75 Mm Dia 27 90 Mm Dia 28 110 Mm Dia 29 125 Mm Dia 30 140 Mm Dia 31 160 Mm Dia 32 180 Mm Dia 33 200 Mm Dia 34 225 Mm Dia 35 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Combination Air Release Valve Kinetic Type With Single Chamber Housed Double Orifice And Have 3 Functions, Large Air Exhaust, Small Air Venting And Large Air Intake During Vacuum Of Pipeline Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications:Governing Standard - Awwa C512 , Body And Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float & Internal Trim: Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbrdrilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside Fasteners - Cs / Galvanised Steel , Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, Big Orifice Size Should Be Equal Or Larger Than The Inlet Flange Bore, For Fully Comply With Awwa C512. ) , Valve Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. 36 50 Mm Dia 37 Construction Of Air Valve Pillar For Fixing Of Air Valves 38 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 39 100 Mm Dia 40 150 Mm Dia 41 200 Mm Dia 42 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Manually Operated Ci Sluice Valves Of Class Pn 1.0 Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 43 80 Mm Dia 44 100 Mm Dia 45 125 Mm Dia 46 150 Mm Dia 47 200 Mm Dia 48 250 Mm Dia 49 300 Mm Dia 50 Cosntruction Of Valve Chamber For Sluice Valves, Flow Control Valve And Butterfly Valve As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 51 Type - A ( 80 Mm To 100 Mm Dia ) 52 Type - B ( 125 Mm To 200 Mm Dia ) 53 Type - C ( 250 Mm To 350 Mm Dia ) 54 Construction Of Village Transfer Chamber As Per Approved Design, Drawing & Specification Given For Material Of Construction And Completion Of All Works Of Installation Of Sluice Valves, D.Joints, C.I. Pipes, Specials ( Excluding Supply ) Etc. Complete In All Respect To Achieve The Work As Given In The Scope Of Work. 55 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 56 100 Mm Dia 57 150 Mm Dia 58 200 Mm Dia 59 250 Mm Dia 60 300 Mm Dia 61 Construction And Commissioning Of Rcc Intze Type Over Head Service Reservoir Of Following Capacity And Staging As Per The Scope Of Work And Technical Specifications, Consisting Of The Following Main Activities: - 62 A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction. B ) Excavation In All Types Of Soil, Pcc Below Foundation, All Rcc Work, Plinth Protection All Around The Structure Including All Material, Labour, Shuttering, Scaffolding Etc.C ) Ohsr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Edge Of Outer Most Projection Of Ohsr.The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Grade Concrete Laid Over 150Mm Thick Layer Of Compacted Soil.D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface On The Top Dome, Edge Beam And 600 Mm Height Of The Vertical Wall.E ) Conducting Successfully Hydro Test And Water Tightness Test As Per I.S. Code.F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Top Surface Of The Top Dome.G ) Providing And Applying Three Coats Of Cement-Based Paint On The External Surface Of The Container, Balcony, Cone Wall, Columns & Beams Etc..H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss-304 Ladder From Top Dome / Slab To Bottom Dome / Slab Inside Container. I ) Providing And Fixing Of Ms Section Ladder From The Last Landing To Balcony Having Railing All Around It And Ms Ladder With Safety Cage From Balcony To Top Dome / Slab.J ) Providing And Fixing Water Level Indicator ( Float Type ) . 63 K ) Providing And Fixing Of Hand Railing All Around The Balcony, Top Dome And Staircase Consisting Of 25Mm Diameter Class-B Gi Pipe In Two Rows And 1000 Mm High, 50X50x6mm Angle Iron Vertical Post At A Maximum Spacing Of 1500Mm Centres.L ) All Ms Parts To Be Painted With Two Coats Of The Enamel Paint Over The Primer Coat Of Red Oxide.M ) Providing And Fixing Of 150Mm Wide Pvc Water Bar For The Construction Joints In The Container ( Vertical Wall & Cone Wall ) .N ) Providing One Aluminium Portable Ladder Of Appropriate Length To Access First Landing ( 3.5 To 4.5M Above Gl ) From Ground.O ) Lighting Arrestor Consisting Of Providing And Fixing Of 2 Nos.Of Chemical Earthing And Connecting It To The Conical Cover Of Ss Ventilator With Two Separate Gi Strips Of 50Mmx3mm.P ) Ci / Di Puddle Collar Shall Be Fixed In The Bottom Dome / Slab For Connecting Inlet, Outlet, Overflow And Washout Pipe Of The Reservoir.Q ) Painting The Name Of The Scheme And Other Details On The Reservoir, And Any Other Work Related To Structure As Per The Directions Of Engineer-In- Charge, Technical Specification And Scope Of Work.R ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 64 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 18 M 65 100 Kl 66 150 Kl 67 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 20 M 68 100 Kl Each ( 100 X 2 Nos. ) 69 200 Kl Each ( 200 Kl X 3 Nos. ) 70 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 71 100 Mm Dia 72 150 Mm Dia 73 200 Mm Dia 74 Construction Of Boundary Wall Of Brick / Stone Masonary As Per Enclosed Ga Drawing, Scope Of Work And Technical Specifications Complete Work In All Respect. Brief Details Of Boundary Wall Parameter Is As Below:1. Depth Of Foundation- 900 Mm.2. Pcc In M-10, Width -900 Mm And Thickness 100 Mm, 3. Section Of Foundation Above Pcc W-600 Mm, D-450Mm, W- 450Mm, D-450 Mm.4. Superstructure Work: Stone Masonary W-300, Height-1650 Mm, / Brick Work W-230 Mm, Height- 1650 Mm.5. Cement Mortar Pointing On Stone Masonary And Cement Mortar Plaster 20 Mm Thick On Brick Masonary In Cm 1:6.6. Expansion Joint Shall Be On Every 30 Mtr.7. On Top Of Wall There Shall Be Cc Coping 75 Mm Thick ( 1:2:4 ) Shall Be Provided.8. Pillar For Main Gate 350X350 Mm In Size Is Part Of Boundary Wall.9. Cement Paint Of Approved Colour In 3 Coat Shall Be Done. 75 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. 76 Dismantling Of Cement Concrete Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 77 Providing And Laying In Position Cement Concrete M10 Grade Nominal Mix 1:4:8 ( 1 Cement : 4Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) In Base Course Complete Including All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. 78 Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. M20 Grade Nominal Mix1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 79 Dismantling Of Flexible Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Madefor Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work. 80 Bituminous Courses 81 Granular Courses 82 Provision For Restroration Of Bitumen Road After Laying & Jointing Pipe Line As Per Direction Of Engineer In Charge 83 Provision Forrestoration Of Wbm Road Cutting As Per Specifications. 84 Total Length Of Canal Corssing During Laying Of Pipe At Various Locations 85 Providing Service Connection As Per Technical Specification And Standard Drawing As Per Relevant Is Code ( Ammended Up To Date ) From All Kind Of Water Mains Up To Consumer Meter / Premises ( Complete Job ) . This Job Includes Digging Out Suitable Size Of Pits And Trench For Laying Service Line In All Kinds Of Soil Including Demolishing Of Cement Concrete, Wbm, Black Top Etc. Of All Thickness; Cutting Of Cc Road / Jhiri By Using A Concrete Cutter Machine; Depositing And Refilling Of Pit & Jhiri Watering And Ramming / Compacting In Layers And Disposal Of Surplus Excavated Soilas Directed With In A Lead Of 50 Meter; Providing And Fixing Of All Fitting Duty Approved In Accordance With Iso / Dtr 9080 As Per Specification For Portable Water Including Approved Make Of Ms / Pvc Clamp With Saddle Piece, Gunmetal Ferrule 4.0 Mm ( Isi Make ) , Valve ( Is: 778 ) And Specials With Mdpe Pipe Pe 80 Pn 12.5 As Per Iso 4424 Below Ground Level And P&F Gi Pipe 15 Mm Dia Class B ( Isi Mark ) Above Ground Level In The Premises For Fixing Tap ( Max. Length2.0 Mtr. ) , P&F A 15 Mm Bib Cork With Foam Flow Chrome Plated With Complete Brass Body Including Brass Handle Having Good Quality With Wt 300 To 325 Gm, Including Accessories With Flushing , Cleaning, Disinfecting And Testing Of Pipeline Complete Required For Making Of Service Connection Complete In All Respect Including Labour Charges. In Addition To The Ferrule, An Orrifice Of 4.0Mm Dia Should Also Be Provided In The Service Line At The Entry Pointy Of ConsumerS Property In Such A Way That It Should Be Accessible For Inspection To Vwsc, Phed And Any Other Authority Which Woyld Like To Inspect As And When Required. The Service Line Should Be Laid Atleast 45 Cm Below Ground Level, Except In Case Of Concrete / Bituminous Raods Where Minimum Depth Shall Be 20Cm. For Details Specifications Of Mdpe Pipes Please Refer Technical Specifications Of Bid Document. General Specifications Of Mdpe Pipes Shall Be As Under: The Raw Material Shall Be Virging Pe 80 Blue Compound And Comply With The Requirement Of Iso / Directive Of Testing Material : 9080 With Minimum Required Strength Of 8 Kg / Sq.Cm. ; The Raw Material Shall Be Food Grade Quality ; Ressure Rating Shall Be 12.5 Bar ; The Pipes Shall Bear Iso Marking 86 Removing& Re-Fixing Of Precast Concrete Interlocking Blocks By Manual, Stacking Of Serviciable & Non Serviceable Material Separately. Disposal Of Dismantled Material Lead Up To 50 Mtr. The C.C. Interlocking Paving Blocks Be Laid On Average 25 Mm Thick Bed Of Coarse Sand And The Joints To Be Filled With Fine Sand. Laying Procedure On Compacted Sub Base As Defined. Complete Job Is To Be Executed As Per The Directions Of Engineer In Charge. The Rates To Be Inclusive Of Fixing Of Minimum 70 Percent Reusable Precast Concrete Interlockingblock And Cost Of Required New Precast Concrete Interlocking Block Against Damaged, Including Alllead And Lift As Per Technical Specifications. ( Interlocking Blockmanufactured By Fully Computerized Automatic Stationery Hydraulic Vibro Pressed Machine & Full Computerized Automatic Batching Plant Of Class A-1 As Per Bs:6717-2001. Tensile Splitting Strength And Breaking Load As Per Bs: 6717-2001Colour: Grey Cement Natural Colour. Variation In Dimension : Less Than 1.6 Mm Variation In Thickness: Less Than 3.2 Mm ) 80 Mm Thick 87 Add Extra Over Item No 1.21 & 1.22 For Providing20 Mm Pe80 Pn 16 As Per Iso 4427 Mdpe Pipe Including Excavation, Providing, Laying & Jointing Of Service Line Above 5.00 Mtr. 88 Supply Laying And Pushing Of Ms Casing Pipe Of Specified Thickness Approved By Concerned Department Authority By Trenchless Method Adopting Any Suitable Technology Below Ground At Required Depth Under Running Traffic Condition As Per Highway / Railway Standard Including Carrying Out Survey Work At The Job Site For Determining Underground Cable Trenches Like Telephone, Cable, Water & Sanitary Lines And Resistivity Test For Finding The Soil Strata Using Necessary Equipments For Completion Of Works, Mobilizing Of Machineries And Specialized Crew At The Job Site Complete In All Respect, Including Excavation Of Driven Pit And Exit Pit ( Up To 3 Meter Depth ) With Proper Protection At These Sites With Shoring Sheets And Ismb. Providing Ms Cutting Edges For Front Shield And Constructing Thrust Bed At Designated Level. Necessary Dewatering And Providing Concrete Foundation At The Base Of The Driven Pit, Pvc / Rubber Saddle As Per The Requirement Of Highway / Railway Authority, Crane For Handing Of Pipe And Any Other Machinery, Tools, And Tackles Required, Construction Of Temporary Works As Per Design, Drawing And Method As Per Approved Byauthority Specification And The Direction Of The Engineer.Apply Corrosion, Resistant, Protection On Inside And Outside Of Casing Pipeas Per Technical Specification. 89 300 Mm Dia 8 Mm Thick Casing Pipe With Protective Coating. 90 Part B : Pump House & Cwr 91 Fabrication, Supply Of Flanged / Plain Ended Ms Pipe Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixing In Position At All Level / Depths In Trenches Complete Excluding Flanged Jointing Wherever ( Required ) Including All Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer. 92 Ms Pipe Upto 600 Mm Dia ( With Minimum 5Mm Thickness Sheet 93 Ms Pipe Above 600Mm Dia ( With Minimum 6.3Mm Thickness Sheet ) 94 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 95 100 Mm Dia 96 125 Mm Dia 97 150Mm Dia 98 200 Mm Dia 99 250 Mm Dia 100 300 Mm Dia 101 450 Mm Dia 102 500 Mm Dia 103 600 Mm Dia 104 700 Mm Dia 105 900 Mm Dia 106 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 107 100 Mm Dia 108 125 Mm Dia 109 150 Mm Dia 110 200 Mm Dia 111 250 Mm Dia 112 300 Mm Dia 113 450 Mm Dia 114 500 Mm Dia 115 600 Mm Dia 116 900 Mm Dia 117 1000 Mm Dia 118 Cosntruction Of Valve Chamber For Sluice And Butterfly Valves As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 119 Valve Chamber ( 80 Mm To 100 Mm Dia ) 120 Valve Chamber ( 500 To 600 Mm ) 121 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Class Pn 1.6, Motorised Operatednote: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 122 100 Mm Dia 123 150 Mm Dia 124 250 Mm Dia 125 450 Mm Dia 126 500 Mm Dia 127 600 Mm Dia 128 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.6 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 129 100 Mm Dia 130 125 Mm Dia 131 150 Mm Dia 132 250 Mm Dia 133 450 Mm Dia 134 500 Mm Dia 135 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.0 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specificationsand As Per Direction Of Engineer. 136 600 Mm Dia 137 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq 138 295.08 Lps, 59 M Head 139 295.08 Lps, 80 M Head 140 274.12 Lps, 61 M Head 141 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq. 142 25.79 Lps, 70 M Head 143 26.83 Lps, 75 M Head 144 15.14 Lps, 79 M Head 145 Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 Operating At Sync. Speed 2900 Rpm With Requisite Moc Impeller, Priming Funnel, Cock, Suitable Flanges At Suction And Delivery Side. Pump Shall Have Common Shaft For Pump And Motor. Motor Shall Be Suitable For Working On 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor Shall Be Tefc Type And Pump Set Shall Be Suitable For Working At Various Discharge And Head Requirements As Per Scope Of Work. Pump Shall Be Erected Onc.C. Foundation / Cross Channels / Rsj Frame Block With Suitable Foundation Bolts Grouted In C.C. Foundation Block Etc. Complete In All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditions Mentioned In Td. 146 19.31 Lps, 41M Head 147 20.62 Lps, 54 M Head 148 9.93 Lps, 78 M Head 149 26.15 Lps, 44 M Head 150 18.46 Lps, 62 M Head 151 9.39 Lps, 73 M Head 152 Supplying, Erecting, Testing & Commissioning Of Electrically Operated Travelling Crane ( Eot ) .Main Girder & End Carriage Fabricated From Rollled Steel Section, Gear Box For All Motion, Electro Magnetic Friction Disc Type Brakes, All Safety Limit Switches, Lt Wheels En 9, Double Flanged 4No, With Sq. Cage Motor Of Adequate Rating ( Kw ) , Duly Painted Mechanical Cleaning And One Coat Of Primer And Two Coat Of Synthetic Paint And As Per The Direction Of The Engineer. 153 Span 7 M 6 Mtr. Lift 154 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci D / F Sluice Valves Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200 Stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss , Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxicsuitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitable Support Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-Incharge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Ci Sluice Valve Of Class Pn-1.0 155 100 Mm Dia 156 600 Mm Dia 157 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 158 100 Mm Dia 159 600 Mm Dia 160 700 Mm Dia 161 Design & Construction Of Clear Water Reservoirs Of Required Capacity At Following Places, Including Its Piping, Fittings, Etc Complete In All Respect As Per The Scope Of Work & Specifications Given In The Tender Document At The Following Places & Sizes . 162 Tps / Cps Bhaleri 163 Design, Manufacturing And Supply Of Batch Type Electro Chlorinator Of Capacity As Per Requirement Of Site 164 Part : C Repair Works 165 Repair Of Valves From Karamsana To Bhaleri 166 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Di Body Flanged End Tamper Proofkinetic Air Valve Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications: Governing Standard - Awwa C512 / Is:14845:2000 ( Amended Up To Date ) Body, High Pressure Cover , Low Pressure Cover, Cowl Andjoint Support Ring - Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float- Lp Ball & Hp Ball : Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbr , Hp Orifice & Hp Orifice Plug : Bronze / Ss , Bush: Bronze , Flanges As Per Is / Bs, Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside .Fasteners - Cs / Galvanised Steel, Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, With Di Metal Seated D / F Non Rising Stem. Sluice Valves As Per ( Is: 14846 Amendedupto Date ) Pn 1.6 Ratings. Valves Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge. Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. ( Class Pn 1.6 ) 167 150 Mm Dia 168 200 Mm Dia 169 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 170 Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6Sectional Valves 171 150 Mm Dia 172 200 Mm Dia 173 900 Mm Dia With Gear 174 Providing, Lowering, Aligning, Fixing In Position And Jointing Ms Dismantling Joint Fabricated Steel ( Suitable For Sluice Valves Etc. ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioningand As Per Technical Specifications And Direction Of Engineer In-Charge. Class Pn 1.0 / 1.6 175 900 Mm Dia 176 Construction Of Valve Chamber As Per Approved Drawing And Specification Of Engineer In Charge 177 Type G Size Up To 800Mm To 900 Mm 178 Major Repair Of Pmc Office Building, Residential Buildings At Pmc Campus, All Work Civil, Electric, Water Supply, Road, Drainage Cleaning, Horticulture, Etc. Complete 179 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 180 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 181 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 182 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 183 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 184 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 185 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 186 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 187 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 188 Scraping Old Surface And Redoing Lime Loi Or Sandla. 189 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 190 5.5 Mm Thick Plain Glass Panes. 191 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 192 5.5 Mm Thick Plain Glass Panes. 193 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 194 In Existing Roof. 195 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 196 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 197 Depth 50 Mm To 75 Mm. 198 Depth 75 Mm To 100 Mm. 199 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 200 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 201 4Wide 202 6 Wide 203 Panel By 204 Shuttering Ply - 9Mm Thick ( Commercial ) 205 Wire Gauge 14 Mesh X 24 Gauge 206 Plain Glass Panes 4Mm Thick 207 Aldrop Of Mild Steel 208 12 Long X12mm Dia 209 8 Long X 10Mm Dia 210 Stopper Of Aluminium With 211 Single Rubber Gutka 212 Double Rubber Gutka 213 Door Springs Of Mild Steel 214 Steel Hinges 215 For Wooden Chowkhat 3 Size. 216 For Wooden Chowkhat 4 Size 217 For Stone Chowkhat , 4Size 218 Mild Steel Tower Bolt 6 Long 219 Steel Locking Bolt 220 Steel Handle 6 Size 221 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 222 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 223 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 224 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 225 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 226 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 227 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 228 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 229 Hot Rolled Deformed Bars ( Is : 1139 ) . 230 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 231 20 Mm Thick. 232 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 233 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 234 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 235 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 236 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 237 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 238 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 239 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 240 Sand Or Other Approved Stone 25 Mm Thick. 241 Sand Or Other Approved Stone 35 Mm Thick. 242 Sand Or Other Approved Stone 50 Mm Thick. 243 Kota Stone 25 To 30 Mm Thick. 244 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 245 Jhunjhunu / Jalore ( Red / Choclate Colour ) 246 Above 3601 Cm2 Slabs 247 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 248 Size Of Tile 60X60 Cm 249 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 250 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 251 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 252 Size 100X75mm. 253 Size 125X100mm. 254 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 255 Size 125 X 100Mm. 256 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 257 30 Mm Thick Shutter 258 Commercial Veneer Both Side 259 Decorative Teakveneer One Side 260 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 261 30 Mm Thick Ghana Teak Wood Grade - I 262 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 263 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 264 1:3:6 Or Richer Mix. 265 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 266 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 267 In Cement Mortar. 268 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 269 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 270 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 271 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 272 Ms Sheet 18 Swg 273 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 274 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 275 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 276 14 Mesh X 24 Gauge 277 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 278 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 279 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 280 Providing & Fixing 12 Mm Thick Tegular Edge Glass Fibre Reinforced Gypsum False Ceiling Tiles Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections ( Galvanized @ 170 Gsm / Sqm. ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30Mm Thick ( Minimum ) Sheet Spaced At 1200Mm Center To Center And Cross “T” Of Size 24X25mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200Mm Long Spaced Between Main “T” At 600Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600Mm And Size 24X25mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grids Of 600X600mm And Wall Angle Of Size 21X21x0.30 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Wherever, Required, Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Fixed To Ceiling With 6 Mm Dia And 50Mm Long Dash Fasteners, 4Mm Gi Adjustable Rods With Galvanised Level Clips Spaced At 1200Mm Center To Center Along Main T, Bottom Exposed Width Of 24Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete At All Heights As Per Specifications Drawings And As Directed By Engineer-In-Charge. 281 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 282 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 283 Old Work ( One Or More Coats ) . 284 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 285 Two Or More Coats On New Work. 286 One Or More Coats On Old Work. 287 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 288 For Area Of Each Slab Up To 900 Sq. Cm 289 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 290 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 291 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 292 Add 10 % For Water Supply And Sainatry Works 293 Add 10 % For Electric Works 294 Horticulture 295 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 296 Girth From 300 Mm To 600 Mm 297 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 298 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 299 From Yard Manure ( Organic ) 300 Compost 301 Goat Dungmanure 302 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 303 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 304 Methly Prathion 2% 305 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 306 Different Flowing Plants 900 Mm To 1500 Mm 307 Different Varrities Of Shrubs 600 Mm To 900 Mm 308 Different Varrities Of Climbers 900 Mm To 1500 Mm 309 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 310 In Rows 7.5 Cms. Apart In Either Direction 311 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 312 Road And Drainage Work 313 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 314 Grading - Ii Material 315 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 316 Crusher Broken -Grade-Ii ( 63-45Mm ) 317 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 318 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 319 With Bitumen Vg-Grade 30 320 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 321 With Bitumen Vg-Grade 30 322 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 323 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 324 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 325 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 326 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 327 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 328 200 Mm Internal Diameter 329 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 330 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 331 Providing And Laying Lean Cement Concrete 1:4:8 In Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg / Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing Complete As Per Clause 601, 112 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion 332 Providing And Laying Un-Reinforced, Plain Cement Concrete Mix With Concrete Mixer & Vibrator Pavement Over A Prepared Sub Base With 43 Grade Cement , Coarse And Fine Aggregate Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed As Per Approved Mix Design, Laid, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints Etc Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 333 Pcc M-30 334 Campus Lighting 335 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 336 7 Mtr 337 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 338 Single Arm Overhang 339 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 340 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 341 10.0 Sq.Mm2 Cor 342 Add 5% Over Head 343 Repair Of Pump House Building At Churu, Bhaleri Like Repair Of Plaster, Floor, Roof, Doors, Windows, Colour Washing, Painting Etc. 344 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 345 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 346 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 347 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 348 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 349 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 350 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 351 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 352 Scraping Old Surface And Redoing Lime Loi Or Sandla. 353 Patch Repair To Cement Concrete Floor Including Digging Out Old Floor In Regular Shape And Removal Of Rubbish Curing Etc. Complete In All Respects. 354 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 355 5.5 Mm Thick Plain Glass Panes. 356 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 357 In Existing Roof. 358 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 359 Depth 50 Mm To 75 Mm. 360 Depth 75 Mm To 100 Mm. 361 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 362 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 363 4Wide 364 6 Wide 365 Panel By 366 Shuttering Ply - 9Mm Thick ( Commercial ) 367 Wire Gauge 14 Mesh X 24 Gauge 368 Plain Glass Panes 4Mm Thick 369 Aldrop Of Mild Steel 370 12 Long X12mm Dia 371 8 Long X 10Mm Dia 372 Stopper Of Aluminium With 373 Single Rubber Gutka 374 Double Rubber Gutka 375 Door Springs Of Mild Steel 376 Steel Hinges 377 For Wooden Chowkhat 3 Size. 378 For Wooden Chowkhat 4 Size 379 For Stone Chowkhat , 4Size 380 Mild Steel Tower Bolt 6 Long 381 Steel Locking Bolt 382 Steel Handle 6 Size 383 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 384 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 385 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 386 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 387 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 388 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 389 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 390 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 391 Hot Rolled Deformed Bars ( Is : 1139 ) . 392 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 393 20 Mm Thick. 394 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 395 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 396 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 397 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 398 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 399 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 400 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 401 30 Mm Thick Shutter 402 Commercial Veneer Both Side 403 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 404 30 Mm Thick Ghana Teak Wood Grade - I 405 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 406 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 407 1:3:6 Or Richer Mix. 408 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 409 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 410 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 411 Ms Sheet 18 Swg 412 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 413 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 414 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 415 14 Mesh X 24 Gauge 416 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 417 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 418 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 419 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 420 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 421 Old Work ( One Or More Coats ) . 422 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 423 Two Or More Coats On New Work. 424 One Or More Coats On Old Work. 425 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 426 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 427 75 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 428 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 429 For Area Of Each Slab Up To 900 Sq. Cm 430 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 431 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 432 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 433 Add 5 % For Water Supply And Sainatry Works 434 Add 10 % For Electric Works 435 Horticulture 436 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 437 Girth From 300 Mm To 600 Mm 438 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 439 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 440 From Yard Manure ( Organic ) 441 Compost 442 Goat Dungmanure 443 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 444 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 445 Methly Prathion 2% 446 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 447 Different Flowing Plants 900 Mm To 1500 Mm 448 Different Varrities Of Shrubs 600 Mm To 900 Mm 449 Different Varrities Of Climbers 900 Mm To 1500 Mm 450 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 451 In Rows 7.5 Cms. Apart In Either Direction 452 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 453 Road And Drainage Work 454 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 455 Grading - Ii Material 456 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 457 Crusher Broken -Grade-Ii ( 63-45Mm ) 458 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 459 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 460 With Bitumen Vg-Grade 30 461 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 462 With Bitumen Vg-Grade 30 463 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 464 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 465 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 466 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 467 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 468 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 469 200 Mm Internal Diameter 470 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 471 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 472 Campus Lighting 473 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 474 7 Mtr 475 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 476 Single Arm Overhang 477 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 478 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 479 10.0 Sq.Mm2 Cor 480 Repair Of Residantialbuilding At Churu, Bhaleri, Like Repair Of Plaster, Floor, Roof, Doors, Windows, Color Washing, Painting Etc. 481 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 482 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 483 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 484 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 485 Scraping Old Surface And Redoing Lime Loi Or Sandla. 486 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 487 5.5 Mm Thick Plain Glass Panes. 488 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 489 5.5 Mm Thick Plain Glass Panes. 490 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 491 In Existing Roof. 492 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 493 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 494 Depth 50 Mm To 75 Mm. 495 Depth 75 Mm To 100 Mm. 496 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 497 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 498 4Wide 499 6 Wide 500 Panel By 501 Shuttering Ply - 9Mm Thick ( Commercial ) 502 Wire Gauge 14 Mesh X 24 Gauge 503 Plain Glass Panes 4Mm Thick 504 Aldrop Of Mild Steel 505 12 Long X12mm Dia 506 8 Long X 10Mm Dia 507 Stopper Of Aluminium With 508 Single Rubber Gutka 509 Double Rubber Gutka 510 Door Springs Of Mild Steel 511 Steel Hinges 512 For Wooden Chowkhat 3 Size. 513 For Wooden Chowkhat 4 Size 514 For Stone Chowkhat , 4Size 515 Mild Steel Tower Bolt 6 Long 516 Steel Locking Bolt 517 Steel Handle 6 Size 518 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 519 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 520 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 521 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 522 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 523 20 Mm Thick. 524 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 525 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 526 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 527 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 528 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 529 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 530 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 531 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 532 Kota Stone 25 To 30 Mm Thick. 533 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 534 Jhunjhunu / Jalore ( Red / Choclate Colour ) 535 Above 3601 Cm2 Slabs 536 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 537 Size Of Tile 60X60 Cm 538 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 539 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 540 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 541 Size 100X75mm. 542 Size 125X100mm. 543 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 544 Size 125 X 100Mm. 545 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 546 30 Mm Thick Shutter 547 Commercial Veneer Both Side 548 Decorative Teakveneer One Side 549 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 550 30 Mm Thick Ghana Teak Wood Grade - I 551 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 552 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 553 1:3:6 Or Richer Mix. 554 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 555 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 556 In Cement Mortar. 557 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 558 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 559 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 560 Ms Sheet 18 Swg 561 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 562 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 563 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 564 14 Mesh X 24 Gauge 565 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 566 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 567 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 568 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 569 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 570 Old Work ( One Or More Coats ) . 571 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 572 Two Or More Coats On New Work. 573 One Or More Coats On Old Work. 574 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 575 For Area Of Each Slab Up To 900 Sq. Cm 576 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 577 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 578 Add 10 % For Water Supply And Sainatry Works 579 Add 10 % For Electric Works 580 Repair Of Boundry Wall At Pmc, Bhaleri, Including Provinf Fixing Of Borbed Wire Fancing Repair Of Gates Et. 581 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 582 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 583 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 584 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 585 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 586 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 587 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 588 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 589 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 590 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 591 Columns, Pillars, Posts And Struts Etc. 592 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 593 Hot Rolled Deformed Bars ( Is : 1139 ) . 594 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 595 20 Mm Thick. 596 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 597 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 598 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 599 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 600 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 601 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 602 Old Work ( One Or More Coats ) . 603 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 604 Two Or More Coats On New Work. 605 One Or More Coats On Old Work. 606 Part : E Electrical Works 607 33 Kvring Main Unit Consisting Of 2 Lbs At Incoming & 2 VcbSoutgoing As Per Requirements And Specifications. 608 Stranded Compact Circular Aluminium Conductor, Conductor Screened With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screened With Copper Tape, Cores Laid Up, Inner Sheath Of Pe Type, Galvanised Steel Flat Strip Armoured And Overall Pvc Sheathed Cable Confirming To Is 7098 / Ii / 85 With Latest Amendments Of 33 Kv ( Ue ) 609 3Cx300 Mm2 610 Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kit Of Approved Make Suitable For Xlpe Insulated 33 Kv Cable, With Required Components, Prepration Of Cable Ends, Testing Etc. 611 3 Core 240 / 300 / 400 Sq.Mm 612 Outdoor 613 Indoor 614 Sitc Of Floor Mounted Pmcc ( Indoor, Dust Proff Ip-4X Front Operated With 2 Mm Thick Sheet Metal Compartmentalised ) With All Accessible Parts, Head Shrinkable Sleeves, Smc / Dmc Bus Bar Supports, Padlocking Facility On Outgoing Feeders Etc. 615 Lv Capacitor With Apfc Panel 616 Sitc Of Microprocessor Based Intelligent Power Factor Correction Relay Having Sensitivity Up To 50 Milli Amp Secondary Current And Following Way, Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Minimum Three Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Indication Of Switching On Units, Auto / Manual Status, And 6 To 14 Stage - Sensitivity Upto 50 Milli Amp. 617 Sitc Of Self Healing Mpp / Mp Type Shunt Capacitor ( Banks ) Conforming To Is:13340-41 / Iec :831-1&2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.5 Watt Per Kvar. Including Making Connections With Suitable Capacity Conductors / Cables Testing As Required.Heavy Duty Three Phase 440 V , 50 Hz Capacitor ( Bank ) 618 P / Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Iind Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. 619 3 / Cx6 Sq Mm 620 3 / Cx10 Sq Mm 621 3 / Cx16 Sq Mm 622 3 / Cx25 Sq Mm 623 3 / Cx240 Sq Mm 624 Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Aluminium Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. 625 3 / Cx6 Sq Mm 626 3 / Cx10 Sq Mm 627 3 / Cx16 Sq Mm 628 3 / Cx25 Sq Mm 629 3 / Cx240 Sq Mm 630 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Covering 631 3C X 2.5 Sq.Mm 632 5Cx1.5 Sq Mm 633 14Cx1.5 Sq Mm 634 Supply & Makingone End Termination With Heavy Duty Single Compression Brass Gland Sibg Type, Copper Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Arrmoud Pvc Insulated And Pvc Sheated / Xlpe Almunium Cunductor Cable Of 1100 Volt Grad As Required Size. 635 3C X 2.5 Sq.Mm 636 5C X 2.5 Sq.Mm 637 14 C X 2.5 Sq.Mm 638 Supply, Fabricating & Installing Following Sizes Of Perforated Cable Trays Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Suspenders And Including Painting As Required. 639 600Mm X 50Mm X 2.0Mm 640 150Mm X 50Mm X 1.6Mm 641 Supply, Installation, Testing And Commissioning Of Copper Wound Transformers 33 / 0.433 Kv, Three Phase, 50 Hz, Dyn 11, Onan Type , Standard Accessories With Off Load Tap Changer ( +5% To -10% In Steps Of 2.5% ) , Winding / Top --- Temperature Rise Of 45°C / 40°Cfirst Fill Oil, Having Permissible Total Loss Values Not Exceeding 7.5% Of The Maximum Total Loss Values For 11 Kv As Per Energy Efficiency Level - 2 At Basic Insulation Level Conferming To Iss 2026 ( Part- I To Part - Ii ) , Latest Ammended And Is 1180 Part-I : 2014. Transformers Described As Above And As Per The Following Continuous Rating 642 400 Kva 643 1250 Kva 644 1600 Kva 645 S.I.T.C. Of Bus Duct Arrangement In Convenient Sections Complete With Enclouser Of Crca Sheet Steel Of Minimum 2 Mm Thickness, Aluminium Bus Bar And Earth Bus For Use On 3 Phase, 4 Wire, 415 Volts, A.C. Supply With Degree Of Protection Ip-42 For The Following Current Carrying Capacity, Including Jointing Of Sections, Copper Flexible Joints. Expansion Joints, Bends, And Earthing With 2 Runs Of Alum. Strips Etc. As Required 646 1 Straight Run With 2 Earth Bus 3200 Amp 647 Bend 3200 Amp 648 Copper Flexible Tpn 3200 Amp 649 Supply Installation Testing & Commissioning Of Local Push Button Stations 650 Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I. Coating Of The Size G.I. Pipe 3000 Mm Long , 80 / 40 Mm , Terminal 14 Mm G.I. Strip 651 S & Laying Following Size Earth Wire / Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection Etc. As Required. 652 50Mm X 6Mm G.I. Strip 653 25Mm X 6Mm G.I. Strip 654 25Mm X 3Mm G.I. Strip 655 10 Swg G.I. Wire 656 P & F Lightning Conductor Final Made Out Of 25 Mm Dia., 300 Mm Long Copper Tube Having Single Prong At Top With 85 Mm Dia., 3 Mm Thick Copper Base Plate Including Holes Etc. Complete As Required. 657 Part : F Instrumentation & Scada 658 Sitc Of Ultrasonic Level Transmitter Suitable For Measuring Water Level In Reservoir, Normal Powered 24Vdc, Type Of Transmitter: Two Wire ( 4-20 Ma ) , Cable Entry:1 / 2 Npt ( F ) , Sensor Material: Pp, Slip-On Flange: 2 ½” Flange, Material Of Construction For Slip-On Flange: Pp, Output 4~20Ma, Hart Compatible, Accuracy + / _ 0.2 % As Per Detailed Technical Specification, Scope Of Work And Direction Of Engineer In Charge. Measuring Range 0.0 To 6.0 Mtr 659 Providing, Installation, Testing And Commissioning Of Diaphragm Type Pressure Gauges Dial Size 150 Mm Glycerin Filled Shatterproof Glass, Over Range Protection: 125% Of Maximum Pressure, Material Of Sensor And Other Wetted Parts: Ss Type 316, Housing Material: Die Cast Aluminum 660 Providing, Installation, Testing And Commissioning Of Pressure Transmitter For Water Application: Range: 0-10 Bar / Power Supply: 24 V Dc / Output: 4-20 Ma With Hart / Diaphragm: Ss316l / Process Connection: 1 / 2 Npt ( M ) / Accuracy: 0.15% Protection: Ip671 / 2 M ( Npt ) 661 Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 662 150 Mm Dia 663 200 Mm Dia 664 250 Mm Dia 665 400 Mm Dia 666 900 Mm Dia 667 Sitc Of Bulk Flow Meter With Removable Mechanism Class B Confirming To Iso:4064:2005 / Is: 2373Of Approved Make Of Following Dia Sized Pipelines And Specifications Complete:Media : Water ( Clear ) , Temp. 50 Deg., Pr. Rating: Pn16, Protection Type: Ip- 68, Body Material : Is-210 Gr. Fg-200, Accuracy Class :Class B ( ±2 % @ Nominal Flow Rate ) , Magnetic Drive, Dry Dial, Epoxy Powder Coated, Pulse Out Put Option, Anti-Magnetic Protection Including All Materials And Making Connection With Existing Pipeline Required For Bulk Flow Meter Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 668 Bfm 100 Mm 669 Bfm 150 Mm 670 Bfm 250 Mm 671 Sitc Of Rtu Complete With Di, Do, Ai And Modbus Communication Ports And Power Supply ( 24 V, Dc ) 672 Providing And Laying Stranded / Flexible Annealed Bare Copper Conductor , Xlpe / Pvc Insulated 2 Pair 1.5 Sqmm Suitably Laid Up Together Overall Polyester Taped Al ( Mylar Tape Wrapped ) Along With Atc Drain Wire Overall Pvc Sheathed ( St-1 ) Overall Screened Triad Armoured Instrumentation Cables Generally Confirming To Pas 5308- Part-2-2009 673 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Coveringsize 3C X 2.5 Sq.Mm 674 Supply, Installation, Testing And Commissioning Of Mnre Approved Off Grid Solar Panels For Running Of Motor Pumps With 25 Years Of Linear Generation Warranty, Work Includes Designing Of Solar Panel Area And Ms Frame And Foundation On Ground / Roof Of Pump House Or Cwr, Showing Arrangement Of Panel In Available Space, Installation Of Pv Module On Ms Frame As Per Approved Design And Drawings. Mounting Structure Shall Be Suitably Design To Withstand Wind Velocity Up To 150Km / Hr. The Work Shall Be Executed As Per Detailed Technical Specifications, Approved Drawing And Direction Of Engineer In Charge. Note: There Shallbe5 Year Service Warranty For Solar Panel And Mounting Structure Andsuitable Provision Shall Be Included In Tender Document ( Each Of .5 Kw ) 675 P&F Of Gsm / Gprs Based Data Transmitter Device Forwater Meter Compitable To Scada System. 676 Supply, Installation, Testing, Commissioning Of Plc / Scadasystem Including All Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations. 677 Cps Bhalari 678 Supply, Installation, Testing, Commissioning Of Master Control Room Including All Plc / Scadasystem, Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations.Churu 679 Part G : Operation & Maintainance & 680 Cost Of Operation And Maintenance Of The System For 10 Years After Defect Liability Period Of One Year @ 6.0%On Above Items Excluding Villages Inrta Systemand As Per Scope Of Work & Specification 681 Operation And Maintenance Charges 1St Year 682 Operation And Maintenance Charges 2Nd Year 683 Operation And Maintenance Charges 3Rd Year 684 Operation And Maintenance Charges 4Th Year 685 Operation And Maintenance Charges 5Th Year 686 Operation And Maintenance Charges 6Th Year 687 Operation And Maintenance Charges 7Th Year 688 Operation And Maintenance Charges 8Th Year 689 Operation And Maintenance Charges 9Th Year 690 Operation And Maintenance Charges 10 Th Year 691 Part H : Dismantling Of Old Pump Sets 692 Cost For Dismantling Of Old Pump Sets, Electrical Panels And Intrumentation Etc And Depositing In Depatmental Stores As Per Direction Of E.I.C. 693 Tps Karamsana 694 Ir-4 695 Cps / Tps Bhaleri 696 Cps / Tps Churu
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
32.
Health and Family Welfare #10170492 Price Bid
Supply Of Ct Scanner 16 Slice Model A , Ct Saccner Inclusive Of All Accessories And Other Items Mentioned In The Specification Which Are Not Specifically Mentioned Below , Additional Workstation As Per Spec , High Pressure Injector Single Head , Full System Ups , Personal Computer With Laser Printer , Lead Apron With Tyriod Gurad , Dry Imager , Led View Box , Civil Works : Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area 3 Sq. Metres And Below , Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Dismantling Old Electrical Points, Wiring, Lights And Handing Over The Same To The Hospital Authorities , Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles 10 Mm To 25 Mm , Dismantling Of Toilet Fittings Including Pipe Lines , Closets, Washbasin Etc To Complete , Anti- Termite Treatment : Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified. Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , Diluting And Injecting Chemical Emulsion For Post-Constructional Anti- Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) : Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300 Mm Including Excavation Channel Along The Wall &Rodding Etc. Complete: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Upto 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed : All Kinds Of Soil , Providing Cable Trench For System Cables And Wherever Necessary With Metal Cover Including Finishing Works And All Allied Works , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) . , Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Up To Plinth Level. Thermo-Mechanically Treated Bars. , Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) , 12 Mm Cement Plaster Of Mix : 1:4 ( 1 Cement: 4 Fine Sand ) , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorptions Less Than 0.08%And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portion Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) . Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Providing And Fixing 12Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is:12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge. Pre-Laminated Particle Board With Decorative Lamination On Both Sides. , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 5.50 Mm Thickness , Providing And Fixing Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000Mm ) With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete. , Providing And Fixing 100Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete. , Providing And Fixing Sun Controlled Film On Glass Surface For Door / Windows, After Thoroughly Cleaning And Dust Free The Surface To Get Smooth Finish, To Get Air Tight Clean Surface, Ect, Complete As Directed By Engineer-In -Charge , Providing And Fixing Aluminium Handles Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete : 125 Mm , Providing And Fixing Aluminium Tower Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete : 250X10 Mm , Providing And Fixing Aluminium Tower Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete : 150X10 Mm , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5Mm Dia X 50Mm Long With 6Mm Dia Bolts Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts &Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Rate Of 1200Mm Centre To Centre To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size3.5 X 25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3Layers Covering Upto 150 Mm Or Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufactures Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : 12.5 Mm Thick Tapered Edge Gypsum Plain Board Conforming To Is: 2095- Part I. , Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595 X 595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams Per Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85X 30X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer -In-Charge. 12.5 Mm Thick Square Edge Pvc Laminated Gypsum Tile Size 595X595 Mm Made Of Gypsum Plasterboard , Manufactured From Natural Gypsum As Per Is 2095 Part I And Laminated With White 0.16 Mm Thick Fire Retardant Pvc Film On The Face Side And 12 Micron Metalized Polyster On The Back Side With All Edges Sealed With The Face Side Pvc Film Which Goes Around And Wraps The Edges And Is Bonded To The Edges And The Back Side Metalized Polyster Film So As To Make The Tile A Completely Sealed Unit , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : One Or More Coats On Old Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : One Or More Coats On Old Work , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade Old Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm ) Over Existing Cement Paint Surface. , Providing And Fixing White Vitreous China Extended Wall Mounting Water Closet Of Size 780X370x690 Mm Of Approved Shape Including Providing& Fixing White Vitreous China Cistern With Dual Flush Fitting, Of Flushing Capacity 3 Litre / 6 Litre ( Adjustable To 4 Litre / 8 Litres ) , Including Seat Cover, And Cistern Fittings, Nuts, Bolts And Gasket Etc Complete. , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690Gms. 15 Mm Nominal Bore , Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require : White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour.600Mm Long Towel Rail With Total Length Of 645Mm, Width 78Mm And Effective Height Of 88Mm, Weighing Not Less Than190gms. , Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 20 Mm Pipe 10 Kgf / Cm2 , Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 75 Mm Pipe 6 Kgf / Cm2 , Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf / Cm2 , Constructing Soak Pit 1.20X1.20X1.20M Filled With Brickbats Including S.W. Drain Pipe 100 Mm Diameter And 1.20 M Long Complete As Per Standard Design. , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 32 Mm Dia , Providing And Fixing Pvc Door Frame Of Size 50X47mm With A Wall Thickness Of 5 Mm ( ± 0.2 Mm ) Made Out Of Single Piece Extruded Pvc Profile, With Mitred Cut Joints And Joint With 2Nos Of Pvc Bracket Of Size 190 Mm X 100 Mm Long Arms Of Cross Section Size 35 X 15Mm & Self Driven Self Taping Screws, The Vertical Door Profiles To Be Reinforced With 40X20mm M.S. Rectangular Tube Of 0.8 Mm , Including Providing Epdm Rubber Gasket Weather Seal Throughout The Frame, Including Jointing 5Mm Pvc Frame Strip With Pvc Solvent Cement On The Back Of The Profile. The Door Frame To Be Fixed To The Wall Using 8X100mm Long Anchor Fasteners Complete, All As Per Manufacturers Specification And Direction Of Engineer -In- Charge. , 35 Mm Thick Factory Made Solid Panel Pvc Door Shutter Made Out Of Single Piece Extruded Solid Pvc Profiles, 5 Mm ( ± 0.2Mm ) Thick, Having Styles &Rails ( Except Lock Rail ) Of Size 95 Mmx 35 Mm X 5 Mm, Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered ( On Both Side ) , Having One Side Thickness Of 15 Mm Integrally Extruded On The Hinge Side Of The Profile For Better Screw Holding Power, Including Reinforcing With Ms Tube Of Size 40 Mmx 20 Mm X 1 Mm, Joints Of Styles & Rails To Be Mitered Cut & Joint With The Help Of Pvc Solvent Cement, Self Driven Self Tapping Screws & M.S. Rectangular Pipes Bracket Of Size 190 Mm X 100 Mm Of Cross Section Size 35 Mm X 17 Mmx 1 Mm At Each Corner. Single Piece Extruded 5Mm Thick Solid Pvc Lock Rail Of Size 115 Mm X 35 Mm X 35 Mm, Out Of Which 95 Mm To Be Flat And 20 Mm To Be Tapered At Both Ends, Having 15 Mm Solid Core In Middle Of Rail Section Integrally Extruded, Fixing The Styles & Rails With The Help Of Solvent And Self Driven Self Tapping Screws Of 125 Mm X 11 Mm, Including Providing 5 Mm Single Piece Solid Pvc Extruded Sheet Inserted In The Door As Panel, All Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. Non Decorative Finish ( Matt Finish ) . , Providing And Laying Rectified Glazed Ceramic Floor Tiles 300X300 Mm Or More ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours White, Ivory, Rey, Fume Red Brown, Laid On 20Mm Thick Cement Mortar 1:4 ( 1Cement : 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored ( 30Mm ) Lead ( 2Mm ) Lined Flush Door Side Hung Two Rebated Shutters With Plywood ( 6Mm ) & Laminated ( 1Mm ) On Both Sides And All Accessories ( Ss Hinges ( 4 Nos ) , Tower Bolt , Ss Handles Etc.. ) , Lead Lined Door Frames: Lead ( 2Mm ) Lined Flush Door Side Hung Single Shutter With Plywood ( 6Mm ) &Laminated ( 1Mm ) On Both Sides And All Accessories ( Lead Sheet Should Overlap Door Frame & Wall ) Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood / Jack Wood ( Frame Size 12 Cm X 8 Cm ) , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood , Providing And Fixing Paneling Or Paneling And Glazing In Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) Paneling For Paneled Or Paneled And Glazed Shutters 25 Mm To 40 Mm Thick Using Good Quality Anjili / Jack Wood , Wood Frame For Fixing Lead Glass ( Lead Sheet Should Overlap Door Frame & Wall ) , Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves, Shutter With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primerincluding All Fittings As Per The Direction Of Site Engineer-In-Charge. ( Total Area Of The Shutter Only Measured ) . , Steel Cupboard ( Godrej ) For Storage 6Ft Tall 3 Feet Width , Cubicle Curtain With Hanger: Should Be Track And Curtain Type, 2. Track Shall Be Made Of High Quality Aluminum, 3. Should Have Stain Free Curtain Material, 4. Manual Operation, 5. Per Meter Rate For Aluminum Track And Curtain Material Shall Be Offered , Computer Table ( Long ) With Keyboard Tray, Cpu Storage At Basein A Side And Storage Drawers At Other Side. ( For Workstation And Reports ) Reputed Brandgodrej / Featherlite / Wipro , Revolving Chair - Pushback, Pu Arms, Pneutic Height Adjustment And Nylon Base. Reputed Brand Like Godrej / Featherlite / Wipro , Miscellaneous Works:- Pvc Name Plates - 24 ( L ) X 4 ( H ) , Site Cleaning , Supply, Installation, Testing & Commissioning Oflt Panel , Cubicle Type, Made Out Of 2Mm Thick Crca Sheet, Totally Enclosed, Ip 42, Free Standing, Floor Mounting, Dust And Vermin Proof, Indoor, Compartmentalised, Suitable For Operation On 3 Phase , 415 V, 50Hz Ac System With Busbars , Including Internal Wiring With Suitable Sizehffr Wires / Cable, Interconnection, Duly Powder Coated With Seven Tank Process Etc., Including All Inter Connections And Following Components As Per Drawing And Technical Specifications. Incomer 200 A Fp 36Ka Mccb With Adjustable Microprocessor Based Release With Ol & Sc Protection - 1 Nos. Busbars 200 Ampere Tpn Busbars Of Aluminum Alloy High Conductivity With Heat Shrinkable Coloured Sleeves Instruments Digital Type Multifunction Meter With Cts Of Suitable Rating For Measurement Of Voltage, Current, Frequency, Power Factor, Kva, Kw, Kwh. - 1 Noefr - 1 Noon / Off Indication Lamps-1Set Ryb Indicating Lamps Led Type - 3 Nos. Outgoings160a Fp. 25Ka Mccb With Adjustable Microprocessor Based Release With Ol & Sc Protection - 1 Nos. 100A Fp 25Ka Mccb With Adjustable Microprocessor Based Release With Ol & Sc Protection -2 Nos.63A Fp 25Ka Mccb With Adjustable Microprocessor Based Release With Ol & Sc Protection - 2 Nos. , Supply, Installation, Testing & Commissioning Oflt Panel ( Ups ) , Cubicle Type, Made Out Of 2Mm Thick Crca Sheet, Totally Enclosed, Ip 42, Free Standing, Floor Mounting, Dust And Vermin Proof, Indoor, Compartmentalised, Suitable For Operation On 3 Phase , 415 V, 50Hz Ac System With Busbars , Including Internal Wiring With Suitable Sizehffr Wires / Cable, Interconnection, Duly Powder Coated With Seven Tank Process Etc., Including All Inter Connections And Following Components As Per Drawing And Technical Specifications. Incomer 160 A Fp, 25Ka Mccb With Adjustable Microprocessor Based Release With Ol & Sc Protection - 1 Nos. 200 Ampere Tpn Busbars Of Aluminum Alloy High Conductivity With Heat Shrinkable Coloured Sleeves Instruments On / Off Indication Lamps-1Set Ryb Indicating Lamps Led Type- 3 Nos. Voltmeter ( 0-500V ) With Selector Switch - 1 No. Ammeter ( 0-400A ) - 3 No. Outgoings125 A Fp 25 Ka Mccb With Adjustable Microprocessor Based Release With Ol & Sc Protection - 1 Nos. 100 A Fp 25 / 16Ka Mccb With Adjustable Microprocessor Based Release With Ol & Sc Protection - 4 Nos.63 A Fp 25 / 16Ka Mccb With Adjustable Microprocessor Based Release With Ol & Sc Protection - 2 Nos. , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 125A, 35 / 36 Ka ( Ics=100%Icu ) , 3 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) Tpn, Mcb Db, 4 Way ( 8+12 ) , Double Door, Horizontal Type , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 125A, 35 / 36 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) Tpn, Mcb Db, 6 Way ( 8+18 ) , Double Door, Horizontal Type , Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A, Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required. ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 4 Way ( 4+12 ) , Tpn, Vertical Type, Mcb Db, Double Door , Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “B” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 6 A. To 32 A. Ratings , Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 6 A. To 32 A. Ratings , Supplying And Fixing Following Rating 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63A Tp Mcb, C-Curve Mcb , Supplying And Fixing Following Rating 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40A Tp Mcb, C-Curve Mcb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 100 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5 / 6 Amps Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 / 16 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5 / 6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15 / 16 Amp Socket Outlet , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 Amps Modular Socket Outlet And 5 / 6 Amps Modular Switch, Connection Etc. As Required. , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 25A Dp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 25 A3 Pin Shuttered Socket Modular , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 4 X 1.5 Sq. Mm + 2 X 1.5 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 4 X 2.5 Sq. Mm + 2 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 4 X 4 Sq. Mm + 2 X 4 Sq. Mm Earth Wire , Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In Existing / Recessed Steel / Pvc Conduit As Required. 1 Run Of Cable , Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In Existing / Recessed Steel / Pvc Conduit As Required. 2 Run Of Cable , Supplying And Drawing Following Pair 0.5 Sq Mm Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 2 Pair Cable , Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group C , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet Rj 11 , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Cat 6 Rj 45Computer Jack , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module ( 100Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module ( 200Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module ( 125Mmx125mm ) , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W ( Max ) , 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Supplying And Fixing Of Wall / Ceiling Mounted Type Ip 65 Circular Led Fitting, 15 W Along With Led Lamp , Powder Coated Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm In Pop / Gypsum Board Ceiling, Wipro / Philips / Bajaj / Havells Etc , Supply & Fixing 20W Led Cool White / White Type Tube Light Light Fittings Philips / Havells / Similar Superior Make , Supplying And Fixing Of 6 / 7 W Bayonet Cap Type Led Bulb In The Existing Angle Batton Etc As Required ( Philips, Wipro Or Similar Superior Make ) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Require. 4C X 95 Sq.Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.4C X 95 Sq.Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required. 4C X 70 Sq.Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required 4C X 70 Sq.Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Require. 4C X 50 Sq.Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required 4C X 50 Sq.Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Require. 4C X 25 Sq.Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required 4C X 25 Sq.Mm , Ssupply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Require. 4C X 16 Sq.Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required 4C X 16 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade As Required. 4C X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade As Required. 4C X 70 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade As Required. 4C X 50 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade As Required. 4C X 25 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade As Required. 4C X 16 Sq.Mm , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25 Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. , Providing And Fixing Earth Bus Of 50 Mm X 5 Mm Copper Strip On Surface For Connections Etc. As Required. Copper Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) , Providing And Fixing 4Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing As Required , Supplying , Installation, Testing And Commissioning Of 1200 Mm Ceiling Fans With Bee 5 Star Rating For Energy Efficiency, Including Wiring The Down Rods Of Standard Length ( Upto 30Cm ) With 1.5Sq Mm Fr Pvc Insulated, Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing 2 Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supply, Installation, Testing And Comissioning Of Residential Type Light Duty Exhaust Fan 900 Rpm, 300 Mm, In Plastic Housing Light Dutyin The Existing Opening, Including Louver / Shutter, Making The Hole To Suit The Size Of The Above Fan, Making Good The Damage, Connection, Testing Commissioning Etc As Required , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes ( Make: M / S Almonard / Crompton / Bajaj Or Equivalent ) , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Suitable De- Humidifier Units : Extraction At Least 35 Litres / Day, Compresor : Rotary, Air Flow : At Least 220M3 / Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval, Energisation Sanction And Regularizing The Additiona Load With Kseb Including Revising The Ht Agreement. , 2 Kg Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , 4 Kg Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Superior Brands, Cooling Capacity 3000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Supply, Conveyance Testing And Commissioning Of 1.5 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Superior Brands, Cooling Capacity 4500 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Supply, Conveyance Testing And Commissioning Of 2 Ton 4 / 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Copper Pipe With Superlon Insulation For Suction And Discharge ( For Additional Length Which Exceeds Thecopper Pipe Supplied Along With The Machine ) , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable ( Size As Per The Requirement Of Ac Manufacturer ) , Supporting Stand For Fixing Outdoor Unit ( Powder Coated ) , Ductable A / C Units 11 Tr X 2 Nos ( 2 Outdoor Unit Of 11Tr And 2 Ahu ) Low Side Works For Complete Installation & Commissioning Of Ac Supply, Installation, Testing & Commissioning Of 11 Tr Or Higher Capacity Aircooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fitting, Gss Sheet Metal Duct ( Insulation Using Resin Bounded Glass Wool With 7 Micron Aluminium Foil ) For Air Distribution 22 / 24 G, Idu Ss Drain Pan As Per Specification Complete With Suitable Capacity Drive Motor , Aircooled Condensor With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Support For Fixing Idu / Odu, Safety Devices Including Thermal Protector, Pressur Releafe Valve, Overload Relay Single Phase Preventer Etc, Power Wiring And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out Suitable For 3 Phase 440V Supply Etc Complete As Required. The Two Units Shall Work Alternatively. Should Have Provision To Change Automatically In Prefixed Time. Should Also Have Provision To Control Both Unit Manually. Quote Rate For 2 11Tr Outdoor And Indoor Unit With Ducting And Other Accesories. ( Not Taken For Evaluation ) , Ductable A / C Units8.5 Tr X 2 Nos ( 2 Outdoor Unit Of8.5Tr And 2 Ahu ) Low Side Works For Complete Installation & Commissioning Of Ac Supply , Installation , Testing & Commissioning Of 8.5 Tr Or Higher Capacity Aircooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fitting, Gss Sheet Metal Duct ( Insulation Using Resin Bounded Glass Wool With 7 Micron Aluminium Foil ) For Air Distribution 22 / 24 G, Idu Ss Drain Pan As Per Specification Complete With Suitable Capacity Drive Motor , Aircooled Condensor With All Accessories , Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Support For Fixing Idu / Odu, Safety Devices Including Thermal Protector, Pressur Releafe Valve , Overload Relay Single Phase Preventer Etc, Power Wiring And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out Suitable For 3 Phase 440V Supply Etc Complete As Required. The Two Units Shall Work Alternatively. Should Have Provision To Change Automatically In Prefixed Time. Should Also Have Provision To Control Both Unit Manually. Quote Rate For Two 8.5Tr Outdoor And Indoor Unit With Ducting And Other Accesories. ( Not Taken For Evaluation ) , Ac Trap Door ( Not Taken For Evaluation ) , Pressure Injector Dual ( Not Taken For Evaluation )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
33.
Science and Technology #10055799 Price Bid
Tender For Renovation / Refurbishment / Upgradation Works In Health Centre At Csir-Cecri, Karaikudi.; 1 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2 Of area 3 sq. metres and below 3 Of area beyond 3 sq. metres 4 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. 5 Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : 6 Of sectional area 40 square centimetres and above 7 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 8 For thickness of tiles 10 mm to 25 mm 9 Dismantling the existing old damaged wash basin & sink including necessary fittings as directed by the Engineer-in-charge. 10 Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. 11 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: 12 G.S. Sheet 13 Demolishingbrickworkmanually/bymechanicalmeansincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 14 In cement mortar 15 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 16 Closing the minor holes upto 0.10sqm area in existing mansonry wallls with necessary plastering and neat finishing as directed by the Engineer-in-charge 17 Removing old unnecessary clamps , angles ,curtain rods and other unwanted minor parts projected in walls & roofs. the rate inclusive of all lift and leads including necessary scaffolding as directed by the Engineer-in-charge. 18 Removing and placing the existing wooden furnitures and other movable items after executing the work including proper placing, cleaning wherever & whenever required as directed 19 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 20 Nominal concrete 1:3:6 or richer mix (including equivalent design mix) 21 Demolishing the existing wethering course laid in roofs and including disposal / levelling near the site as directed. 22 Supplying chemical emulsion in sealed containers including delivery as specified. 23 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 24 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 25 Along the external wall below concrete or masonry apron [email protected] linear metre including drilling and plugging holes etc.: 26 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 27 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : 28 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 29 Providing and injecting approved grout inproportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) 30 Stirrer mixed SBR Polymer (of approved make) modified Cement slurrymade with Shrinkage Compensating Cement in concrete/RCC work. 31 Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as perspecifications and direction of Engineer- In-charge complete in all respect. 32 Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make 33 Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modifiedself curing mortar, including disposal of rubbish, all completeas per the direction of Engineer-In-Charge. 34 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 35 All kinds of soil. 36 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 37 Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth 38 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) 39 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 40 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 41 Cement mortar 1:6(1 cement :6 coarse sand) 42 Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in : 43 Cement mortar 1:6 (1 cement: 6 coarse sand) 44 Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in super structure above plinth upto floor V level. 45 Cement mortar 1 : 4 (1 cement : 4 coarse sand) 46 12 mm cement plaster of mix: 47 1:6 (1 cement: 6 coarse sand) 48 Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : 49 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 50 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 51 Providing,transporting,hoistingandfixingaboveplinthlevelupto floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). 52 Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. 53 Thermo-Mechanically Treatedbars of gradeFe-500D or more. 54 Centering and shuttering including strutting, propping etc. and removal of form for 55 Lintels,beams,plinthbeams,girders,bressumersand cantilevers 56 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded stone aggregate 6 mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and sofits. 57 50 mm thick 58 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 59 Second class teak wood 60 Providing and fixing ISI marked flush door shutters conforming to IS : 2202(PartI)non-decorative type,core of blockboardconstruction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 61 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 62 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 63 Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). 64 Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 65 Frame size 45 x 85 mm 66 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 67 30 mm thick 68 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. 69 Extra for providing vision panel not exceeding 0.1sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 70 Rectangular or square 71 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 72 Providing and fixing bright /matt finished Brass tower bolt of approved quality & make with necessary screws etc all complete. 300mm x 10mm 73 Providing and fixing Stainless steel latest ornamental fancy handle 1metrelong including necessary screws as directed by the Enginner- in -charge 74 Providingandfixingaluminiumextrudedsectionbodytubulartype universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 75 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 76 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanizedmild steel section madeof requiredshape & size asper CPWDSpecification,uPVC extrudedglazingbeads,interlocksandlnlinesashadaptor(where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) 77 shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. 78 Note:-StructuraldesignproofcheckedfromaGovernment Engineering Institute,tobeprovidedbythemanufacturerfor (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds Two and half track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. 79 Using R3 series with frame (85 mm & above) x (40 mm & above) & glazed sash (30 mm & above) x (55 mm & above) & fly screen sash (20 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated handle on every glazedpanelalongwithmulti-pointlocking system. (Height upto 1.8 metre). 80 Fixed window/ ventilator without mullion /transom. 81 Using R2 series with frame (39 mm & above) x (39 mm & above). (Height upto 1.2 metre) 82 Providing and fixing glazing in UPVC window, ventilator shutters and partitions etc. as per the architectural drawings and the directions of engineer-in-charge. With colour glass panes of 4.0 mm thickness 83 Providing and fixing fiber glass mesh mosquito net in UPVC window, ventilator shutters etc. withas per the architectural drawings and the directions of engineer-in-charge. 84 Providing and fixing horizontal cassette roller blinds (Zebra) made of synthetic fabric of polyester /cotton with required pattern . Cassette mounting brackets shall support both the roller tube and the cassette. They must be capable of mounting inside, outside or to the ceiling, with the clutch on either right or left hand side of the roller. Cassette shall be installed to conceal the roller tube and mounting hardware. Cassette shall be made of approximately extruded aluminium and shall be painted with a high quality baked enamel finish, or finished with an anodized finish. Size of cassette depends on the size of blind.Cassette shall be able to accommodate a coordinated fabric insert and as directed by the Engineer-in-charge. 85 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : 86 For fixed portion 87 Powder coated aluminium (minimum thickness of powder coating 50 micron) 88 Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 89 Powder coated aluminium (minimum thickness of powder coating 50 micron) 90 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 91 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 92 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 93 Providingandfixingcupboardshutterwith 19mmthickoneside decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2 mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge. (Payment of providing and fixing auto closing hinges shall be paid separately) 94 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 95 1.0 mm thick 96 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVCfoil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/ kitchen cabinet etc. of required sizes comprisingof virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class A 97 category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 98 18 mm thick 99 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 100 200 mm 101 Providing and fixing bright /matt finished Stainless Steel tower bolt of approved quality & make with necessary screws etc all complete. 100x10mm 102 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 103 50 mm 104 Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel chromium plating grade 1as per IS:1068 and fixing with necessary screws etc., complete. 105 Overall width 35 mm 106 Providing and fixing false ceiling at all heightincluding jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting & frame work with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I 107 Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets andgalvanized with zinc coating of 120 gms/sqm(bothside inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm 108 long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, 109 all as per manufacturers specification and also including the cost of making openings for light fittings, grills, difusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 110 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main T runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross T of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between mainT at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick 111 (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main T runners to be suspended from ceiling using al. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main T. Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 112 Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection >85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. 113 Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 114 Glazed Vitrified tiles Matt/Antiskid finish of size 115 Size of Tile 600 x 600 mm 116 Providingandfixing 18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters,window sills,facias andsimilar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 117 Granite stone slab of colour black, Cherry/Ruby red 118 Area of slab over 0.50 sqm 119 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 120 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 121 Providing and fixing white vitreous china laboratory sink 32 mm C.P brass waste fitting , suitable felxible PVC waste hose , and 32mm C.P . brass trap with necessary C.P . brass unions complete, including cutting and making good the wall wherever required : Size 600x450x200 mm 122 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 123 15 mm nominal bore 124 Providing and fixing wash basin with Rackbolt, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste fittings & waste hose of standard pattern,wherever required White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 125 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 126 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 127 W.C. pan with ISI marked white solid plastic seat and lid 128 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 129 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 130 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 131 15 mm nominal bore 132 Providing and fixing PVC multi trap (Nahini trap) with jalli including necessary fittings as directed by the Engineer - in- charge. 100mm dia 133 Providing and fixing CP two way tap of approved quality as directed by the Engineer-in-charge 15mm nominal bore 134 Providing and fixing CP coatedhealth faucet 1.0mtr length of approved quality with necessary fittings and screws as directed by the Engineer - in -charge 135 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 136 Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms. 137 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 138 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 139 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. 140 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 141 Inside size 90x80 cm and 45 cm deep including C.I. coverwithframe(lightduty) 455x610mminternal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 142 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 143 Providing and fixingPVC SWR pipes Type B conforming to IS:13592 including jointing with necessary fittings as directed by the Engineer-in-charge. 150mm diameter 144 Providing and fixingPVC SWR pipes Type B conforming to IS:13592 including jointing with necessary fittings as directed by the Engineer-in-charge. 110mm diameter 145 Providing and fixingPVC SWR pipes Type B conforming to IS:13592 including jointing with necessary fittings as directed by the Engineer-in-charge. 63mm diameter 146 Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 147 All kinds of soil 148 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 149 ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 150 20 mm nominal dia Pipes 151 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 152 25 mm nominal dia Pipes 153 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 154 25 to 40 mm nominal bore 155 Providing and fixing CPVC ball valve of approved quality, High or low pressure, with plastic floats complete as directed by the Engineer -in -charge. 25 mm nominal bore 156 Providing and fixing granite of 18 mm thick gang saw cut, mirror polished (double side), premoulded and prepolished, machine cut for urinal spearator and similar locations of required size (1300mm x 600mm), approved shade, colour, textureand fixing the walls as per site condition, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 157 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mmwith fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 158 Providing and fixing CP brass urinal half turn valve of aprroved quality as directed by the Engineer-in-charge. 15mm nominal bore 159 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 160 Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for pressed clay roof tiles as directed. 161 Providing & Applying polymer modified, flexible cementatiouswaterproofing coating with elastic waterproofing polymers on roofsurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer(dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. 162 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 163 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 164 Hot finished welded type tubes 165 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 166 In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete 167 Providing and fixing precoated galvanised iron profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 168 Providingand fixingexpansionhold fasteners onC.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 169 Wedge expansion type 170 Fastener with threaded dia 12 mm 171 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 172 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 173 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 174 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approvedbrandandmanufacture,includingapplyingadditionalcoats wherever required to achieve even shade and colour. 175 Two coats 176 Providing andapplyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. 177 Finishing walls with Acrylic Smooth exterior paint of required shade: 178 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 179 Finishing walls with textured exterior paint of required shade: 180 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 181 Providing and applying acrylic based granular textured wall coating finish in any shade with spray coat bubble or compact or rustik shade.The rate inclusive of POP punning to the wall with proper level & making grooves and preparation of surface as directed. new work two or more coats applied @ 3.28ltr/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm 182 Cutting holes up to 30x30 cm in walls including making good the same: 183 With common burnt clay F.P.S. (non modular) bricks 184 Providng and fixing precast reinforced cement concrete rings with 25mm thick of size 450mm dia & height 300mm in existing masonry walls with neat finishing as per the direction of Engineer-in-charge. 185 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 186 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 187 Making through holes in plain or reinforced cement concrete / brick masonry wall with diamond core drilling system by mechanical means as directed100mm dia 188 Providing polishing white pebbles stone for vase fillers outdoor / indoor decoration as directed by the engineer-in-charge. size 20mm to 40mm 189 Providing and fixing wall lining / ceiling factory made moulded WPC ( wood polymer composite)louver panel at all height with contemporary design ,jointing and finishing to a flush finish with recommended screws all as per manufacturers specification including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge. (Excluding the cost of frame work or backing boards) 160 wide x23 mm thick 190 Cutting / Carving of plywood / ACP sheet/WPC/PVC/ cement board with CNCoperations in the required patternas directed by the Engineer-in-charge upto 25mm thick 191 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, bufing, polishing andmakingcurvature(wherever required)andfittingthesame with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 192 Making letter with 12mm thick WPC sheet in all colours including neccssary machine cutting andneat finishing with sutable font. Fixing and placing in position at required height with neccssary screws / bolt & nuts. The rate inclusive of all transport charges , scaffolding and neccssary fittings as directed by the Engineer In-charge. 200mm high 193 Providing and fixing PVC beading for corner of the ceramic glazed wall tiles area and positioning as approved by engineer in charge. 194 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 195 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 196 Providing and fixing 9 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with Non -decorative lamination on both sides 197 Providng and fixing precast reinforced cement concrete rings with cover 25mm thick of size 900mm dia & height 300mm by using 6mm mild steel reinforcement 100mm c/c in both direction. The rate inclusive of all lifts and leadsas directed by the Engineer-in-charge. 198 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. 199 Weathering course using best quality of broken jelly of 20mm gauge in pure slacked lime (no sand to be added) over roof slab the proportion of brick jelly to lime being 32:12.5 by volume and laid over in a single consolidated to the required design and finished thickness by beating the concrete with wooden beater to the size required slope of approved pattern and keeping the surface constantly wet by sprinkling lime jaggery water as per standard specification and as directed by the departmental officers. 200 Providing and laying pressed clay tiles (as per approved pattern 18 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. 201 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 202 Fixed to openings /wooden frames with rawl plugs screws etc. 203 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 204 Providing and fixing glass door stainless steel lock of approved quality , design and make with necessary fixing arrangements as directed by the Engineer-in-charge. 205 Supplying and fixing self adhesive decorative film for glass doors/ winows /glass partition/backing of suitable boards including requireddesign as directed by the Engineer-in-charge. 206 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 207 150 x 100 mm size P type 208 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 209 Supplying and Fixing of stainless steel (304 grade) polished CSIR-Emblemfinished with suitable mounding struds inluding neat finishing at directed by Engineer-in-charge 450mm dia 210 Dismantling doors, windows,wooden board,wooden frames,aluminium partitions,false ceiling materials and clerestory windows (steel ,aluminium or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 1500 metres lead (store yard) : 211 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 212 For pipes 100 to 250 mm diameter 213 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 3 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / 214 Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws,nuts,bolts, washers,cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain 215 wall with aluminium compositepanel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 216 Providing and fixing on wall face unplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 217 110 mm diameter 218 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. 219 Bend 87.5° 220 110 mm bend 221 Shoe (Plain) 222 110 mm Shoe 223 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 224 Group C 225 Wiringfortwincontrollightpointwith 1.5sq.mmFRLSPVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 226 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. 227 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 228 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 229 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 230 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 231 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 232 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 233 4 X 10 sq. mm + 2 X 6sq. mm earth wire 234 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 235 Supplyingand drawingfollowingpair 0.5mmdiaFRLSPVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 236 2 Pair 237 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 238 25 mm 239 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 240 100 mm X 100 mm X 60 mm deep 241 200 mm X 150 mm X 75 mm deep 242 200 mm X 300 mm X 100 mm deep 243 Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. 244 5/6 A switch 245 15/16 A switch 246 3 pin 5/6 A socket outlet 247 6 pin 15/16 A socket outlet 248 Telephone socket outlet 249 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 250 Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. 251 1 or 2 Module (75mmX75mm) 252 3 Module (100mmX75mm) 253 6 Module (200mmX75mm) 254 12 Module (200mmX150nnm) 255 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 256 Installation,testingandcommissioningofpre-wired,fluorescent fitting / compact fluorescent fittingof alltypes,complete withall accessoriesand tube/lamp etc.directly on ceiling/ wall,including connectionswith 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 257 Numberingofceilingfan/exhaustfan/fluorescentfittingsas required. 258 Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 259 Group C 260 Supplying and fixing following way,horizontal type three pole and neutral,sheetsteel,MOBdistributionboard, 415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 261 4 way (4 + 12), Double door 262 6 way (4 + 18), Double door 263 8 way (4 + 24), Double door 264 Supplyingand fixingof following ways surface/ recessmounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.) 265 4 way (4 + 12), Double door 266 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. 267 Single pole 268 Double pole 269 Triple pole 270 Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required. 271 Supplying and fixing DP sheet steel enclosure on surface/ recess alongwith 25/32A240VCcurveDPMCBcompletewith connections, testing and commissioning etc. as required. 272 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 273 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415Volts,onsurface/recess,completewithtestingand commissioning etc.as required. 274 For 4 way, Double door TPN MCBDB 275 For 6 way, Double door TPN MCBDB 276 For 8 way, Double door TPN MCBDB 277 Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete withtesting and commissioning etc. as required. 278 Supplyingandinstallingfollowingsizeof perforatedpaintedwith powdercoatingM.S.cabletrayswithperforationnotmorethan 17.5%,in convenient sections, joined with connectors, suspended fromtheceilingwithM.S.suspendersincludingbolts&nuts, painting suspenders etc as required. 279 150 mm width X 50 mm depth X 1.6 mm thickness 280 300 mm width X 50 mm depth X 1.6 mm thickness 281 Supplyingandinstallingfollowingsizeof perforatedpaintedwith powder coatingM.S.cable traysbends withperforationnot more than 17.5%„ joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 282 150 mm width X 50 mm depth X 1.6 mm thickness 283 300 mm width X 50 mm depth X 1.6 mm thickness 284 Supplyingandinstallingfollowingsizeof perforatedpaintedwith powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincludingbolts&nuts,paintingsuspendersetcas required. 285 300 mm width X 50 mm depth X 1.6 mm thickness 286 Earthing withG.I.earthplate 600mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 287 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 288 Supplying andlaying 25 mm X 5 mm copper strip at 0.50 metre belowground asstrip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 289 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 290 Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required. 291 Providingandfixing4.00mmdiacopper wireonsurfaceorin recess for loop earthing as required. 292 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 293 Laying of one number PVCinsulated andPVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 294 Above 35 sq. mm and upto 95 sq. mm 295 Above 95 sq. mm and upto 185 sq. mm 296 Laying of one number PVC insulated andPVC sheathed / XLPE powercableof1.1KVgradeoffollowingsizeintheexisting masonry open duct as required. 297 Above 35 sq. mm and upto 95 sq. mm 298 Above 95 sq. mm and upto 185 sq. mm 299 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 300 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 301 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mmMS flat clamp) 302 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 303 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 304 Supplyingandmakingendterminationwithbrass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. 305 312 X 70 sq. mm (38mm) 306 3% X 150 sq. mm (50mm) 307 Supplying and fixing of 32 mm dia X 2.00 metres long GI. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 308 Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. 309 Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 310 90 mm dia (00-90 mm & I0-76 mm nominal) 311 120 mm dia (00-120 mm & ID-103 mm nominal) 312 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 313 Removing the existing TPN and SPN DBs,changeover switch Db,SFU’s of all size, Fuse carriers,Main switches, Sub main, circuit and point wirings,switch boards, power boardsfan and light fittings with Various size of cables , removing of Incoming cables/wires for old PDB and LDB and other unused and worn-out electrical installations, and other unwanted Electrical materials in the proposed area complete in all aspects as per site condition and returning the removed items to the departments stores or any such place within the campus area as directed by the engineer in charge as per site condition. 314 Shifting of 15 KVA UPS System (including UPS Unit and Batteries) from passage to proposed new panel room. Scope includes:Disconnecting ,shifting andreconnecting UPS,Batteries (20Nos) power and battery cables, Installation and realignment in new location, Testing and commissioning all required manpower, tools, and accessories as per site condition. 315 LED Street Light Fitting :Supply and fixing ofoutdoor type LED Street light fitting,36W, in the existing pole (up to 40mm dia ) located in site along with all accessories as required as per site condition. Simial to JV Lukers STRADA Model No.LST- 36 or Equivalent as approved by department.(note:The fitting should have 2 years warranty replacement) 316 2 FtLED Batten:Supply of 2 feet extruded aluminium LED batten indoor type 12W, having high efficiency, flicker free suitable for wall, surface and conduit mounting system with required accessories as required. Similar to Philips Endura Smat BrightModel No. BN021 LED12S-6500 PSU GR or Equivalent with time of 25,000 hours as approved by department 317 LED ML Fitting : Supply of LED mirror light fitting of 18 W,WW having high efficiency,wall/ surface mounting with suitbale driver of wide voltage range as required. Similar to JV Lukers LITA T8 Model No.LMCL 18 or Equivalent as approved by department.Note:the fitting shall have 2 years warranty replacement 318 12 Way VTPN DB with 100 A MCCB:Supplying and fixing 12 way surface/ recess MCCB mounting, 415 volts, vertical type TPN MCB distribution board (with wire way/cable end box) of sheet steel,dust protected, duly powder painted, inclusive of 160 amps tinned copperbusbar,commonneutrallink,earthbar,dinbarfor mounting MCBs, along with 100 A,16/25 KA TPN MCCB, phase barrier and spreaders for incomer, interconnection between DB incomer and the bus bars/Existing mains shall be made with copper cables of appropriate rating as required.The VTPN DB shall be mounted on a adequate size angle/flat and grouted/ fixed (drilling,cutting welding painting etc)firmly in the existing wall/ existing base channel as required as per site condition complete in all aspects.The above DB shall include the following C series, 10 kA MCBs in the out going circuits 319 TP MCB-63A-2 NosSP MCB-6-32A-30 NosBlanking plates -As required.Make : Legrand /Schneider /Siemens/Hager or equivalentsubject to the approval of the department. 320 TP +N MCB With Enclosure for AC outdoor:-Supplying and fixing TP+N415 volts, 63 amps,C Series,MCB including Enclosure asrequired as per site condition complete in all aspects . 321 Raceway 100x50 mm: Supply and fixing of100 x 50 mm UPVC cable management complete system / raceway trunking along with all accessories as requiredin surface and carrying out the proposed electrification works complete in all aspects as required as per site condition.Make : MK/ Legrand/Siemens or Eauivalent as approved by department. 322 Raceway 50x50 mm:Supply and fixing of50 x 50 mm UPVC complete cable managementsystem / raceway trunking along with all accessories as requiredin surface and carrying out the proposed electrification workscomplete in all aspects as required as per site condition.Make : MK/ Legrand/Siemens or Eauivalent as approved by department. 323 TP MCB:-Supplying and fixing TP 415 volts, 63 amps,C Series,MCBin the existing DBas required as per site condition complete in all aspects . 324 TP +N MCB:-Supplying and fixing TP+N415 volts, 40 amps,C Series,MCBin the existing DBas required as per site condition complete in all aspects . 325 2x2 LED fitting: Supply and fixing recessed mounting2x2 LED energy efficient fitting, 4200 lumens, around 40 watts,WW/WHalong with suitable driver with ripple less than 5%for flicker/glare-free light in the existing false ceiling with required accessoriessuch as chain/stringfor supporting the fittings firmlyin the ceiling including interconnections as required. Similar to Philips Full Glow G6 Model No : RC380B LED 42S-6500/4000 G6 l60 W60 PSU OD or Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 326 2x2 LED fitting: Supply ofrecessed mounting2x2 LED energy efficient fitting, 4200 lumens, around 40 watts,WW/WH along with suitable drive rwith ripple less than 5%for flicker/glare-free light as required. Similar to Philips Full Glow G6 Model No : RC380B LED 42S-6500/4000 G6 l60 W60 PSU OD or Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 327 Square/RoundLED down lighter :Supply and fixing ofrecessed mounting Square Down lighter LED energy efficient fitting,1200 lumens, 12W, WW/WH light along with suitable driver in the existing false ceiling with required accessories for mounting the fittings firmlyin the ceiling including interconnections as required. Similar to Philips Sleek surface slim profile SM250/260 LED 12S 6500 PSUor Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 328 Square/RoundLED down lighter :Supplyofrecessed mounting Square Down lighter LED energy efficient fitting,1200 lumens, 12W, WW/WH light along with suitable driver in the existing false ceiling with required accessories for mounting the fittings firmlyin the ceiling including interconnections as required. Similar to Philips Sleek surface slim profile SM250/260 LED 12S 6500 PSUor Equivalent as approved by department.(Note:The Fitting Should have 2 years warranty replacement) 329 Smart LED Strip Light : Supply, installation, testing and commissioning of indoor type, 5 mtr, 12 V,25 W,2200 lumens, Smart WiFi Tunable white strip light that works works with voice/ WiZ connected/remote based application along with suitable AC driver of continuous duty,etc having an adhesive for firm fixing and2 years replacement warranty etc.The strip light shall be installed in the existing confernce room wall panel/ false ceilingwith required accessories, interconnections of adequate rated cables complete in all aspects as required as per site condition. Similar to Phlips 5 Mtr WiZ Smart Strip LightProduct SKU : 929003551501 or equivalent as approved by department. 330 4 Ft Industrial LED Batten:Supply of standard 4 feet industrial indoor 40W,LED batten having high efficiency, flicker free suitable for wall, surface and conduit mounting system with required accessories as required. Similar to Philips Endura LED Next Model No. BN308CLED40S-6500 L1 PSD or Equivalent as approved by department.(Note:The LED batten shall have minimum 2 years relacement warranty.) 331 LED Wall Lamp : Supply, installation, testing and commissioning of indoor type bigwall mounted modern creative light fixture LED wall lampmade up of glass or combination of metal and crystal material having Gold/Shining lamp shade, Bold vibe, Abstract pattern and the model will be selected by the engineer in-charge . the basic amount of the fitting should be reckoned as Rs 5000/ (± 5%) excluding GST. operating with AC source of power supply, having a replacement warranty of 1 year, complete with wall lamp and bulb to be suitably mounted in the wall mounting panel and other structures with required accessories, interconnections of adequate rated cables complete in all aspects as required as per site condition. 332 LED Silicon Neon Profile Tube Light Lighting: Supply, installation, testing and commissioning of indoor type, 10 mtr, 24 V,75 W,vibrant lighting with low energy consumptionalong with suitable AC driver of continuous duty,etc having an adhesive for firm fixing and2 years replacement warranty etc.TheProfile Tube Light shall be installed with different meter length in the existing conference room wall panel/ false ceilingwith required accessories, interconnections of adequate rated cables complete in all aspects as required as per site condition. Similar to Harold 10 Mtr Silicon Neon Profile Tube Light or equivalent as approved by department. 333 Butterfly Gold LED Wall Lamp:Supply, installation, testing and commissioning of indoor type bigwall mounted modern CITRA Transparent Acrylic Butterfly Gold LED Wall Lamp Bedside Light - Warm Whitemade up of Metal or combination of metal and crystal material having Gold lamp shade, Bold vibe, Abstract pattern and minimum dimension of 24Lx19Wx12H CM, AC source of power supply, having a replacement warranty of 1 year, complete with wall lamp and bulb to be suitably mountedin the wall mounting panel and other structures withrequired accessories, interconnections of adequate rated cablescomplete in all aspects as required as per site condition. Similar to CITRA Transparent Acrylic Butterfly Gold LED Wall Lamp Bedside Light - Warm White or equivalent as approved by the department. 334 Sun flower Wall Lamp:Supply, installation, testing and commissioning of indoor type bigwall mounted modern Lamp master 3-in-1 LED Sunflower Wall made up of Acrylic or combination of metal and crystal material having Lamp master 3-in-1 LED, Abstract pattern and minimum dimension of 23Lx5Wx23H CM, AC source of power supply, having a replacement warranty of 1 year, complete with wall lamp and bulb to be suitably mountedin the wall mounting panel and other structures withrequired accessories, interconnections of adequate rated cablescomplete in all aspects as required as per site condition. Similar to Lamp master 3-in-1 LED Sunflower Wall & Ceiling Light - Creative Acrylic Decorative Wall Light or equivalent as approved by the department. 335 Exhaust fan CATA C B15 Matic: Supplyingand fixing of window mounted plastic housing of industrial type white colour exhaust fan,automatic shutter, 220-240 V 50 Hz,class B insuslation, theramal cutout,43 dB noise level, 40 Deg ambient, 320 CFM suitable for 150 Sq Ft size room in the existing window of the bathroom as required with necessary accessories, interconnection etc as per site condition. Similar to CATA C B15 Maticor equivalent as approved by department. 336 Supply of constant current LED Driver suitable for 2x2’ Full Glow LED Fitting, with thespecifications is Input Voltage: 140–270V AC, Output: Constant current, suitable for 36W–40W LED, Power Factor: ≥0.95, THD: <10%, Surge Protection: ≥4kV, Efficiency: ≥85%, Specify approved make or “equivalent” 337 Supply of LED Driver for Down lighter LED fitting 12W, 1200 Lumens, WW/WH color. Input: 220-240V AC Output: 12V/Constant Current, PF > 0.9 , Efficiency > 85% , THD < 15%, CE/RoHS compliant andSpecify approved make or “equivalent”. 338 Supplyand installtion of Rubber mat of size (100X200) cm as persite condition at VTPN DB area of thickness as per standard IS 15652. 339 Supplying & fixing of ariel clamp set of Suitable angle for fixing following HRC Fuse Base and Fuselink on the LT polewith 250 AMPS HRC Fuse base (make: L&T) and 250 A HRC Fuse link (make:L& T) with necessary accessories assembled as complete set and mounted in the existing LT pole along with the termination of UG cable as required as per site condition. 340 Dispensary MV Distribution Panel a) Supply, installation, testing and commissioning of In Door type panel manufactured by a CPRI approved panel fabricator compling IS standards.LT Panel Sheet thickness should not be less than 2.00 mm for load bearing members and doors and LT panel cubicle/vertical should be with 9 fold design structure for more strength, with detachable gland plates of 3mm thick for entry of cables from the top/bottom as required with 400A ratings electrolytic copper bus bars with sleeves (100% for phases & 50% neutral & as per standards for earth running all around the panel), free standing, totally enclosed, suitable for 3 phase and neutral. The panel should be modular in design with ZERO welding and suitable for 415 V, 3 phases, 50 Hz, 4 wire systems IP 43 & IK09. The LT panel bus bars shall be supported with the Glass reinforced Polyamide 6.6 type bus bar support suitable up to 140 deg C. Main incoming & outgoing switchgear/circuit breakers should be of same manufacturer and switchgear should be of same series/model of the OEM. 341 No live part should be accessible from the front, while operating the door. Total Discrimination chart should be prepared for all the LT panels & should be submitted before approval along with GA Drawing. Incomer :- 1 No’sof 320 Amps 4 pole Changeover switch parallel with a separate suitable HRC fuse carrier set along with neutral bus on the load side with necessary interconnections as required as per standards etc, direct rotary handle, 2 set of spreader terminal, phase barrier,intersource barrier, shorting links set of 4,415/690 V AC, 100 % Neutral,12.5 kA, insulation voltage of 1000 V Ac, impulse voltage of 12 kV, mechanical and electrical rating of 10000 and 2000 cycles respectively confirming to IS as amended up to date complete withall otheraccessories etc as required. Similar to TSE power line, Frame-2 Cat No.424188 of Legrand or equivalent as approved by department. 342 i) Digital multifunction meter class 1 accuracy, with Rs 485 portoutput for communication toread V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, etc - 1No.ii) 320A/5A CL.1 accuracy, 15VA burden CT - 3 Nos.iii) RYB and ON, OFF, indication lamps for both source connected with suitable control fuse and MCB -1 Set.Outgoing: 8 No’s of100 Amps TPN MCCB (Icu=10 kA=Ics )Thermal magnetic based, 415V, 100% Neutral, rating confirming to IS as amended up to date complete with over current & short circuit protection, spreaders, phase barriers, direct rotary handle etc with required interconnections as required complete in all aspects as required 343 Erection in all aspect including providing necessary angle iron channels for the panel to be mounted on the existing trench/brickwork/panel room, with required fastners, accessories and other allied works deemed to be required to complete as per site condition (including necessary civil works as required and finishing the same to the original condition, along with cable excavation for loose/loop purpose as required.) 344 Supply, fabrication, and installation of CRCA metal enclosure with sealing arrangments as per EB requirements, 2 MM thickness (powder coated) of minimum size 400mm (W) x 300mm (D) x 500mm (H)along with electrolytic copper bus bar rated for 300A, mounted inside the enclosure with suitable supports, sleeves, and interconnections for incomer and outgoing connections and3mm thick detachable gland plates for 150 Sqmm aluminium cable entry from top/bottom as required. The cable end box shall be mounted on a adequate size angle/flat and grouted/ fixed (drilling, cutting welding painting etc) firmly in the existing wall/ existing base channel as required as per site condition complete in all aspects. 345 Shifting of TNEB Metering Board Three Phase: a)Supplying and fixing of suitable size of teakwood plank for fixing of existing meter and other accessories as required.b) Supplying and fixing of required 03 nos of 63A-100A porcelain fuse unit. c)Supplying and Fixing of copper earth strip of size 19mm X 3mmthick of6`` length for earth connections as reqd. The above complete set has to be mounted on wall. The charge including all interconntions and masonry works etc. d)Re fixingor shifting of Existing Meters (10-60A) with new boards including remitting of necessary charges to TNEB for meter shifting on behalf of CSIR-CECRI and co-coordinating with TNEB officials in all aspects in order to charge the meteringboard complete as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
34.
Defence #10031490 AOC
Bids Are invited for Title1 - Water Dispenser with Hot and Cold facility , Title2 - Weight Machine 1 gm to 5 kgs , Title3 , Title4 - Round Stamp , Title5 - First Sight Dak Stamp , Title6 , Title7 - Honour Board , Title8 - Calendar Frame Med Size , Title9 - Digital Wall Clock Big Size , Title10 - Digital Wall Clock Small Size , Title11 - Table Glass 8 mm 6 by 4 ft , Title12 - Window Screen , Title13 - Table Writing , Title14 - Table Cloth Superior Quality 6ft by 6 ft , Title15 - Towel Large , Title16 - Electric Call Bell Superior Quality , Title17 - Electric Call Bell Normal , Title18 - Paper Shredder , Title19 - Towel Hand , Title20 - Measuring Tape 30 mtr , Title21 - Measuring Tape 05 mtr , Title22 - Office Board , Title23 - Floor Sign Board , Title24 - Pad Lock Godrej Navtal 7 Lever 75mm , Title25 - Board Duster , Title26 - Coaster Set , Title27 - Full Plate Set of Six , Title28 - Quarter Plate Set of Six , Title29 - Bowls set of six , Title30 - Borosil Glass Set of Six , Title31 - Dustbin SS , Title32 - Dustbin Plastic 80 ltrs with wheels , Title33 - Dust Bin 60 ltrs with wheels , Title34 - Dettol Hand Wash , Title35 - Room Freshener , Title36 - Mosquito spray Black Hit , Title37 - Lal Hit , Title38 - Colin , Title39 - Lizol , Title40 - Phenyl , Title41 - Harpic , Title42 - Naphthalene Ball , Title43 - Odonil , Title44 - Pocha , Title45 - Wiper , Title46 - Broom Soft , Title47 - Broom Nariyal , Title48 - Dusting Cloth , Title49 - Toilet Brush , Title50 - Washing Powder , Title51 - Glass Wiper , Title52 - Vim bar , Title53 - Scissor , Title54 - White Board 3FT BY 4FT , Title55 - Notice Board 4ft by 5 ft , Title56 - Board Stand , Title57 - Invitation Card , Title58 - Writing pad , Title59 - Folding Table , Title60 - Curtains , Title61 - Electric Tea Kettle , Title62 - Table Lamp , Title63 - Tea or Coffee Making Machine , Title64 - Wall Mounted Fans , Title65 - Models for Sample room , Title66 - Display Telephone M71 , Title67 - Digital Locker , Title68 - Plan Phone Total Quantity : 1644
Contract Date: Ref. Documents Contract Value : 10.15 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
Maharashtra View Result →
35.
Tourism #10027930 AOC
Proposed Conservation And Repair Work To Naroshankar Temple, At.Panchvati,Tq.Dist.Nashik - Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete.SSR 2022-23 Page No.157 Item No. 21.34 2 Removal of plants / ficus grown by pulling out root system embedded in masnory, cutting stem and application of high/gur/lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide Glycel(iso proplamine salt of glyphosate) or other chemical as specified by the Engineer incharge etc. complete.SSR 2022-23 Page No.301 Item No. 46.58 3 Removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. SSR 2022-23Page No. 224 Item No. 35.18 4 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete SSR 2022-23Page No. 297 Item No. 46.19 5 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete S.S.R. 2022 - 23 Page No.296,Item No.46.12 6 Removing brick bat coba including stacking the spoils as directed with all leads,lifts etc, complete. SSR 2022-23Page No.296 Item No.46.14 7 Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete.S.S.R. 2022 - 23 Page No.211,Item No.32.33 8 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etcS.S.R. 2022 - 23 Page No.296,Item No.46.09 9 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete S.S.R. 2022 - 23 Page No.296,Item No.46.15 10 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directedinthe compound including scaffolding etc. complete.S.S.R. 2022 - 23 Page No.235,Item No.38.26 11 Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete.SSR 2022-23Page No.297 Item No.46.29 12 Removing wooden or A.C.partition including frame work and stack-ing the materials as with all leads, lifts etc. complete.SSR 2022-23Page No.296 Item No.46.17 13 Dismantling flat wooden orA.C. Sheet ceiling with framework including stacking the materials as directed with all leads, lifts etc. complete..SSR 2022-23Page No.296 Item No.46.06 14 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.SSR 2022-23Page No.299 Item No.46.42 15 Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete.SSR 2022-23Page No.298 Item No.46.38 16 Specialised Stone cleaning to remove oil or emulsion paint,stains or dark patches,layers of impervious coatings,cementious layers,rust stains from surface of stone with chemicals ,thinners,solvents or soft teepol type soap solution or by pressure jet machine (As specified by consulting architect),A gentle use of air abrasive tools may be permitted as long as no damage to the original surface is ensured.it may include usage of mechanical tapping ,chemical surfactant or solvant,patent cleaning product or use of pressurised micro abrasive as necessary.test patches would need to be undertaken to asses efficeincy of technique prior to work.Removal to be followed by water washing.The surface shall finally be cleaned by hand rubbing and rinsing with clean water to obtain nearly original surface,colour and textureNON SSR R.A.34 17 Gently cleaning the surface of stone masonary with specialised water misting technique employing air water jet usinga fine nossle sprinkling system calibrated to sprey fine mist along the stone surface without over wetting followed up by gentle brushing with soft nylon brushesand removing dirt,dist,bird dropping,grease,oil,algae,fungus,monkey beats,vegetable growth,etc as specified.gentle surface cleaning using water misting and mild pH balanced surfactants as specified for indicated areas to remove the surface dirt,grit accretion by means of water misting and cleaning etc.complete as directed by engineer in chargeBMC -USOR-R3-CS-CH-1,2023 18 Removing pointing and other epoxy-based hard material from joints and surface area of Basalt stone masonary manually with chisel and hammer or with the help of electric grinders wherever directed by Engineer In charge. Proper care should be taken not to damage the stone during removal. 19 Numbering the monument elements in proper order before lowering down with approved colour and shade as directed by Engineer in-charge, including ladder, scaffolding etc.complete.NON SSR R.A No.203 20 Lowering down carefully existing stone masonry of the monument manually in proper order including shifting the stone elements up to a distance of 50 meter beyond the monument area and stacking them as directed by Engineer in-charge, removing building rubbish and cleaning the site etc. complete .NON SSR R.A No.204 21 Providing Lime Pointing to stone work in lime mortar 1:1 in superstructure, as per detailed specifications and drawings or as directed including all face or visible work shall be pointed, unless otherwisespecified and shall be done while the mortar is fresh, the mortar shall consists of lime and fine sandshall not be ground fine but sand should be finer, the joints of the pointed work shall be neatlydefined by the pointing, the lines shall be regular and uniform in breadth and the joints shall beraised or flat as may directed, preparing the lime mortar with 640 gram pulp of wood apple(Belfruit) per cubic metre of lime mortar as a bonding material, watering and all work whenhanded over to be perfectly clean and free from all mortar stains etc. complete Non - S.S.R. Item From Rate Analysis No. 136 of Deapartment Rate Abstract 22 Providing Lime Pointing to brick work in lime mortar 1:1 in superstructure, as per detailed specifications and drawings or as directed including all face or visible work shall be pointed, unless otherwise specified and shall be done while the mortar is fresh, the mortar shall consists of lime and fine sand shall not be ground fine but sand should be finer, the joints of the pointed work shall be neatly defined by the pointing, the lines shall be regular and uniform in breadth and the joints shall be raised or flat as may directed, preparing the lime mortar with 640 gram pulp of wood apple (Belfruit) per cubic metre of lime mortar as a bonding material, scaffolding, watering and all work when handed over to be perfectly clean and free from all mortar stains etc. complete.Non - S.S.R.Item From Rate Analysis No. 138 of Deapartment Rate Abstract 23 Providing injection grouting with lime and fine screened sand slurry in proporation of (1 : 1) with a proper jet pump pressure including cleaning and washing and packing the existing crack / holes in the brick or stone masnory with lime and finesand paste in proporation of (1:1) properly from down side, filling the slurry in cracks or holes including all necessary actions and required tools and machineries, scaffolding, curing etc. complete. for soil stabilizationNon S.S.R. 24 Excavation for foundation in earth, soils of all types sand, gravel and soft murum,Including removing the excavated matreial upto a distance of 50 M beyond the building area stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling ,ramming, watering Including shoring and strutting etc.complete ( Lift upto 1.50m ) SSR 2022-23Page No.153 Item No. 21.01(By manual Means) 25 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. SSR 2022-23Page No.157 Item No. 21.40 26 Compacting the sub grade/gravel/oversize metal (200 mm loose) layers for all width with Vibratory roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete.SSR 2022-23Page No.346 Item No. 50.60 27 Providing and laying cast in situ 1:2:4 Lime Concrete of Trap stone metal for foundation and bedding as per detailed specifications and drawings or as directed including centring, formwork, laying/pumping, compacting, preparing the lime mortar in lime miller and then mixing with coursed aggregate in drum mixer, bailing out water, watering etc. complete.NON SSR R.A. No. 4 28 Providing Un-coursed Rubble Masonry of trap / granite stones in lime mortar 1:1½, in foundation and plinth as per detailed specifications and drawings or as directed including the stones to be set in the work as received from the quarry, after merely knocking off weak corners and edges with the masons hammer, the stones shall be carefully laid so as to break joints, no joint shall exceed 12.5 mm. (½″) in thickness, every stone shall be set flush in mortar, the face stone shall be for greater size, and good beds, one through stone shall be inserted at least every 0.80 sq. mete (1 square yard), the joints shall be racked out carefully at least 25 mm. (1″) where pointing or plastering to be done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, bailing out water, watering and all exposed masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete..(NON SSR R.A No.87) 29 Providing Block In Course Masonry of trap / granite stones in lime mortar 1:1½ with size of stone 0.60m. x 0.45m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the face of stones shall be rough-tooled, rustic (with or without chisel draft, except at quoins), or chamfered as specified, the beds and joints of all ashlar stones to be dressed perfectly true, square and full, headers shall not be less in length than breadth of ashlar stone plus 45 cm. (1ꞌ6″), the stones shall be set in mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 17.5 cm. (7″) in height, the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete.NON SSR 39 30 Providing/Re-setting Stone Paving, Second Sort of reuse-stones in lime mortar 1:1½, per detailed specifications and drawings or as directed including the joints running true, the stones to be laid with joints not exceeding 8 mm. (5/16″) thick and to be evenly and firmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all paving work when handed over to beperfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.152 31 Providing and fixing Stone Paving, SecondSort in lime 1:1/2 mortar, with average size of stone 0.45 m. x 0.30 m. x 0.15m. as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stonestobelaidwithjointsnotexceeding 6mm.(¼″)thick andtobe evenlyandfirmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all pavingwork when handed over to be perfectly clean and free from all mortar stains etc. complete.flooring for ghat and parking NON SSR R.A. No.151 32 Providing and fixing Stone Paving, First Sort in lime mortar 1:1, with size of stone 0.45 m. x 0.30 m. x 0.15 m., as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stones to be laid with joints not exceeding 6 mm. (¼″) thick and to be evenly and firmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all paving work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.149 33 Providing/Re-setting Ashlar Rough tooled Masonry of reuse-stones in lime mortar 1:1 in superstructure as per detailed specifications and drawings or as directed including the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course, the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A No.16 34 Providing Ashlar Rough Tooled Masonry of trap / granite stones in lime mortar 1:1 with size of stone 0.60 m. x 0.45 m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″) in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No15 35 Providing/Re-setting Ashlar Fine Masonry of reuse-stones in lime mortar 1:1 in superstructure as per detailed specifications and drawings or as directed including the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course, the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A No.12 36 Providing Ashlar FineMasonry of trap / granite stones in lime mortar 1:1 with size of stone 0.60 m. x 0.45 m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″) in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No11 37 Providing/Re-setting Ashlar Fine Stone Steps of reuse-stones in lime mortar 1:1 as per detailed specifications and drawings or as directed including each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A No.62 38 Providing Ashlar Fine Stone Steps of trap / granite stones in lime mortar 1:1with size of stone 0.6m. x 0.400 m. x 0.220 m. as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the stones shall be of exact size and shape, the shall be fine dressed on exposed surface, holes for balusters should be cut in the steps before they are laid, each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.61 39 Providing Ashlar Fine Masonry of trap / granite stones for GAUMUKH in lime mortar 1:1 with average size of stone 0.60 m. x 0.45 m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 40 Providing Ashlar Fine Masonry of trap / granite stones for TADKHADA(BASESTONE) in lime mortar 1:1 with average size of stone 0.60 m. x 0.60 m. x 0.60 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 41 Providing Ashlar Fine Masonry of trap / granite stones for Columns/Ganesh Patti/Lintel/Chandrashila/Ardha-Chandrashila in lime mortar 1:1 with average size of stone 0.6 m. x 0.6 m. x 2.70 m in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 11 42 Providing Ashlar Fine Masonry of trap / granite stones for Beams/Ganesh Patti/Lintel/Chandrashila/Ardha-Chandrashila in lime mortar 1:1 with average size of stone 0.51 m. x 0.51 m. x 2.70 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 43 Providing Ashlar Fine Masonry of trap / granite stones for CIRCULAR BRACKET in lime mortar 1:1 with average size of stone 0.70m. x 0.70 m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 44 Providing Ashlar Fine Masonry of trap / granite stones for FOURWAY BRACKET/RECTANGULAR BRACKET in lime mortar 1:1 with average size of stone 0.70m. x 0.70 m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 45 Providing Ashlar Fine Masonry of trap / granite stones for KARNSHILA CAP,KARNSHILA STONES in lime mortar 1:1 with average size of stone 1.85m. x 0.90m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 46 Providing Ashlar Fine Masonry of trap / granite stones for SLAB in lime mortar 1:1 with average size of stone 0.6m. x 0.60 m. x 0.508 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 47 Providing Ashlar Fine Masonry of trap / granite stones for CHAJJA STONES in lime mortar 1:1 with average size of stone 0.9m. x 0.60m. x 0.216 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 48 Providing Ashlar Fine Masonry of trap / granite stones for KAKSHASHAN in lime mortar 1:1 with average size of stone1.85m. x 0.90m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 49 Providing Ashlar Fine Masonry of trap / granite stones for Galtha in lime mortar 1:1 with average size of stone 0.70m. x 0.70m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. completeFor Stone curved shape chajjafor Temple. NON SSR 11 50 Providing Ashlar Fine Masonry of trap / granite stones for Parapet in lime mortar 1:1 with average size of stone 0.60m. x 0.45m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. completeFor Stone curved shape chajjafor Temple. NON SSR 11 51 Providing Ashlar Fine Masonry of trap / granite stones for Shikhar Urshringe block in lime mortar 1:1 with average size of stone 0.40m. x 0.40m. x 0.81 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. completeFor Stone curved shape chajjafor Temple. NON SSR 11 52 Providing Ashlar Arching of trap / granite stones in lime mortar 1:1, with size of stone 60 cm. x 45 cm. x 30 cm. as per detailed specifications and drawings or as directed including the arch stones be of approved quality, colour, hard and free from defect of any kind, the arch stones in all cases of the entire thickness, the arch stones shall be dressed full and true to their proper shapes with the necessary summering, twist or winding and be set in fine mortar, the intrados, joints and beds to fair tooled and left full, the cast or keying course to be accurately fitted, at all horizontal joints the intrados to have a 2 cm. (¾″) chamfer, the face stone may be tooled or rock-faced with or without chamfer as directed, in arches up to 60 cm. (2ꞌ) in depth all stones shall be of the full thickness of the ring, arches to be built on proper centring, the bed joints shall be radial and the side joints shall be at right angles to the bed joints and the thickness of the joints shall not exceed 5 mm. (3/16″) preparing the lime mortar in lime miller, cantering/scaffolding, watering and all archwork when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No125 53 Providing Brick Arching Second Class of second class bricks of size 9″ x 4½″ x 2½″ in lime mortar 1:1½ as per detailed specifications and drawings or as directed including the bricks to be of uniform size, thoroughly well burnt and sound, ringing clearly when stuck with trowel, the bricks to be soaked in water for 12 hours before used, the bricks to be laid in concentric half-brick ring, the joints are to be properly summered and not to exceed 17 mm. (⅔″) in thickness, the joints to be truly radial to the curve at all points, great care to be taken that the rings are bonded together properly,whenever the joints of any of the rings come to a summering or plane face, all arches to be turned on centrings, preparing the lime mortar in lime miller, cantering/scaffolding, watering and all arch work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 133 54 Providing Brick Masonry Second Class in superstructure with size of brick9″ x 4½″ x 2½″ in lime mortar 1:1½, as per detailed specifications and drawings or as directed including the bricks to be of uniform size, moulded ground, thoroughly well burnt and sound, ringing clearly when stuck with trowel, the bricks to be soaked in water for 12 hours before used, the bricks are to be laid flush in mortar in suchbond as directed, as far as possible, bricks of uniform colour are to be selected for theface work when it is not to be plastered, the joints are not to exceed12.5 mm. (½″), no bats or half brick to be usedin the work, racking out joints where pointing or plastering tobe done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 119 55 Carving ornamental work including moulding, grove, chisseling & dresing the same part with fine finishing as per existing/similar type of work of on the stone surface of any type & size or as directed by engineer in charge etc. complete. The charges for chisscling & dressing on stone surface for govering at the stone surface after chisling a fine surface rate for as per market rate. 56 Caving ornamental work on surface including moulding, grove, chisseling & dresing the same part with fine finishing as per existing/similar type of work of on the stone surface of any type & size or as directed by engineer in charge etc. complete.The charges for chiseling & dressing on stone surface for ornamental carving work surface etc. as per existing design. pattern and form as directed by engineer in chargeRates as per R.A. No. 29 57 Providing Soil Bag Support to the monument with contractor´s soil in proper layers carefully as directed by Engineer in-charge including filling, tying and conveying the bags, removing the soil bags after work up to a distance of 50 meter beyond the monument area and cleaning the site etc. complete.For Lowering Down NONSSR206 58 Providing Soil Bag Support to the monument with contractor´s soil in proper layers carefully as directed by Engineer in-charge including filling, tying and conveying the bags, removing the soil bags after work up to a distance of 50 meter beyond the monument area and cleaning the site etc. complete.For Restoring NONSSR206 59 Providing and laying cast in situ 1:1:4 Lime Concrete of broken brick metal for coping or waterproofing as per detailed specifications and drawings or as directed including centring, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required, with fine aggregate, preparing the lime mortar in lime miller and then mixing with coursed aggregate or surkhi in drum mixer, the concrete must be bitten for two days with pouring water as per specifications, scaffolding, watering and all concrete work when handed over to be perfectly clean and free from all mortar stains, etc. complete. NON S.S.R. R.A.6 60 Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete SSR 2022 - 23Page No.245 Item No.39.01 61 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete SSR 2022 - 23Page No.246 Item No.39.08 62 Providing and applying melamine polish of required finish to the wood work byspray machine including knotting and preparing the even surface by scraping,applying French polish , scaffolding if required etc. complete.Note:The work to be executed on prior approval of Superintending Engineer will be necessary.SSR 2022 - 23Page No.222 Item No.34.09 63 Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt.SSR 2022 - 23Page No.294 Item No.44.10 64 Providing12 mm. thick Rough Cast Lime Plaster and 10 mm thick in doublecoat in lime mortar 1:1/2 and 1:1(22 mm) lime putty fine coat on last layer in plinth, as perdetailedspecificationsanddrawingsorasdirectedincludingalljointsinmasonryandbrick work are to be racked out to a depth of at least 20 mm. and the wall to be washed with fresh water andthoroughlywettedforsixhoursbeforeplastering,theplastertobeappliedinanevenand uniform coat well pressed in to the joints and to be well beaten for 1½ days with hand tappers, the plaster should also be well sprinkle during the proses of beating with a mixture of 1.10 jaggary and 640grampulpofwoodapple(Belfruit)in90to135litreofwater,theplasterbeingwetted occasionally with fresh water while the beating is in progress, all exposed angles and junctions with door frame to be carefully finished, all mouldings shall be worked true to template and drawn neat, clean and level, soffits of arches must true arch of circle, preparing the lime mortar in lime miller with 1.60 kg Gugal (a kind of fragrant gum) and 960 gram chopped hemp (fibre of bhendi or tag ) per cubic metre of lime mortar as a bonding material, of lime as a bonding material, watering and allwork when handed over to be perfectly clean and free from all mortar stains etc. complete.NONSSR RA142 65 Stucco work in lime, surkhi and sand (1:1:1) as per traditional practices and design, the mortar should be prepared by grinding mill only. The thickness varies from 10mm to 100mm as per design.NON SSR 2022 - 23 66 Providing and applying integral fine coat, with addition of colour pigments, as paint to the plainlime stucco plaster in 2 layers, including scaffolding, curing, all leads and lifts, etc. complete. 1) The first coat to be laid is a mixture of fine lime and white washing lime in proportion of 2:1,made smooth with wooden rubbers and very lightly beaten. 2)The finishing coat consisting of fine lime, white washing lime, mixed with the appropriate pigment in 1:2:1 proportion is to be applied and well polished with trowels. .NON SSR 2022 - 23 67 Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in- charge, of approved brand and manufacture, diluted withsolventmineral Turpentineoil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sandstonemasonry surfacewith two or more coats to give uniform application of chemical onthe surface, all completeas per direction of Engineer-In-charge (The rate is inclusive of allmaterials& labours involved except scaffolding).Non - S.S.R. 68 Disposing of dismantling materials of R.C.C./ stone / brick masonry / derbies, excavated material / soil / murum / rubbish material or vegetation / grass / shrubs etc., from work site beyond the 5km. SSR 2023-24STATEMENT C1 PG NO.459 69 Providing and fixing of retro-reflectorised informatory sign board rectangular /Square in shape having area greater than 0.9 square meter made out of 2mm aluminum sheet bonded withwhite retroreflective sheeting of Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive / heat activated adhesive retoreflective specified background, border and backside reto reflctive symbols,letters, numerals, arrowasper IRC:67-2012TableNo8.3, supported with back support frame25mmx25mmx3mm,duly painted on back side with two coats of grey stove enamel paint and supported on one Number mild steel angle iron post 75mmx75mmx6mm,3.5mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45cmx45cmx60cm,60cm below ground level asper approveddrawingTheangle ironpost shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paint having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete. The nut bolts of board with angle iron post / supportingstructureafter fixingat sitehas tobeelectrically welded.ClassB(TypeIVHighintensitymicro-prismaticgrade sheeting-HIP) sheeting shall have7 yearswrittenwarranty fromthemanufacturerandauthoriseddistributor / convertor issued for field performance including the screen printed areasandcut-out sheetingandcut-out durable transparent overlay film and this warrantySSR 2022 - 23Page No.58 Item No.6.34 70 Providing and fixing Required Size Granite plate engraving 10 cm. Height letter, figures including painting the lefters/figures with approved colour and shade complete SSR 2022-23Page No.294 Item No.44.12 71 Public Seating Chair. - 3 Seater Providing and Fixing 3seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.SSR 2022-23Page No.359 Item No.51.44 72 Supplying and erecting Solar Street Light Non SSR 73 Preparing and carrying out videography, Documentary & Shooting of still photographs of Extra copies - 5 X 7 Sizeoutdoor and indoor of roads, bridges, other structures and programme, including preliminarys survey, still shots moving shooting, necessary board for video shooting hiring of vehicle, equipment for video shoot­ing, transportation of all equipment, persons, required for shooting, lighting arrangement as may be necessary, editing, mixing, titling, lettering, sounding including cost of coloured cassette of approved quality etc. completeNON SSR 74 Book Designing, Publishing and Printing: The work involves printing of a book / guidebook on the fort / monuments and its various aspects, which would provide authentic and precise tourism oriented information. This work involves important photographsof the site, art objects, antiquities, inscriptions etc., which would be useful for educating the masses of the rich cultural heritage of the site, region and state. providing 100 pages coloured books as directed by engineer in charge / ADA Non SSR 75 Preparation of Photogrammetric and LiDAR Survey Plan of the Monuments/Sites to delineate Protected & Controlled Areas. Scope Photogrammetry, LiDAR, UAV/drone-based surveying, geo-tagging monuments. Non SSR 76 Carrying of detailed topographic survey by using total station along the existing or new road including taking L-section and cross section at every 30 meter ROW ,taking at least 10 spot levels per cross section, picking up all existing details inside the Row like electric telephone line , encroachments, structures etc. connecting all the primary total station control points by G.I.S.Bench marks level or whichever available with department using auto level and preparing Auto CAD plan by using above data taking out 1 set of black and white printout on 50 micron polyster film sheet A2 size and 2 sets of coloured printout on A2 size submitting soft copy all data on CD. Plain Terrain New AlignmentSSR 2022-23 Page No.17 Item No. 1.41
Contract Date: Apr 20, 2026 Contract Value : 2.89 Crore
Government Departments No of Bidders 2
Maharashtra View Result →
36.
Tourism #10023425 AOC
Proposed Conservation And Repair Work To Ajagareshwar Baba Samadhi Temple, Tq.Dist.Nashik- 1 Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. 2 Providing and fixing double scaffolding system(cuplock type)on the exterior sideo f building/structure, including additional rows of scaffolding instepped manneras per requirement of site, madewith40mmdiaM.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes,M.S.tube challis,M.S.clampsandstaircasesysteminthescaffoldingforworkingplatformetc.and maintaining it inaserviceable condition for execution of work of cleaning and/or pointing and/orapplying chemical and removing itthereafter. Thes caffolding systemshallbestiffened withbracings,runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. 3 Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete.SSR 2022-23Page No.298 Item No.46.38 4 Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete.S.S.R. 2022 - 23 Page No.211,Item No.32.33 5 Removing pointing and other epoxy-based hard material from joints and surface area of Basalt stone masonary manually with chisel and hammer or with the help of electric grinders wherever directed by Engineer In charge. Proper care should be taken not to damage the stone during removal. 6 Removing and resetting Mangalore tiles from roof including refixing loose battens etc. complete. S.S.R. 2022 - 23 Page No.235,Item No.38.24 7 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete 8 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. 9 Removing rafters from roof including the materials as directed with all leads, lifts etc. complete. 10 Removing planking from roof or ceiling and stacking them as directed with all leads and lifts etc. complete 11 RemovingG.I.orA.C.sheetroofingincluding purlins,principal raftersetc. includingsorting serviceableand unserviceable materials, stacking the same as and where directed inthe compoundincluding scaffoldingetc.complete. 12 Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. 13 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. 14 Dismantling stone masonry in lime or cement mortar including stacking the materials as directed with all leads, lifts etc. 15 Numbering the monument elements in proper order before lowering down with approved colour and shade as directed by Engineer in-charge, including ladder, scaffolding etc.complete.NON SSR R.A No.203 16 Lowering down carefully existing stone masonry of the monument manually in proper order including shifting the stone elements up to a distance of 50 meter beyond the monument area and stacking them as directed by Engineer in-charge, removing building rubbish and cleaning the site etc. complete .NON SSR R.A No.204 17 Specialised Stone cleaning to remove oil or emulsion paint,stains or dark patches,layers of impervious coatings,cementious layers,rust stains from surface of stone with chemicals ,thinners,solvents or soft teepol type soap solution or by pressure jet machine (As specified by consulting architect),A gentle use of air abrasive tools may be permitted as long as no damage to the original surface is ensured.it may include usage of mechanical tapping ,chemical surfactant or solvant,patent cleaning product or use of pressurised micro abrasive as necessary.test patches would need to be undertaken to asses efficeincy of technique prior to work.Removal to be followed by water washing.The surface shall finally be cleaned by hand rubbing and rinsing with clean water to obtain nearly original surface,colour and textureNON SSR R.A.34 18 Excavationforfoundationinearth,soilsofalltypessand,gravelandsoft murum,Includingremovingthe excavatedmatreialuptoadistanceof50Mbeyondthebuildingareastackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming,wateringIncluding shoring and strutting etc.complete ( Lift upto 1.50m )by manual means 19 Filling in plinth and floors with approved excavated material in 15cm. To 20cm.Layers including watering and compacting etc. complete. 20 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. SSR 2022-23Page No.157 Item No. 21.40 21 Providing and laying cast in situ 1:2:4 Lime Concrete of trap/ granite/ quartzite/ gneiss metal for foundation and bedding as per detailed specifications and drawings or as directed including bailing out water, centring, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required with fine aggregate, preparing the lime mortar in lime miller and then mixing with coursed aggregate in drum mixer as per specifications including bailing out water, watering etc. complete. 22 Providing Un-coursed Rubble Masonry of trap / granite stones in lime mortar 1:1½, in foundation and plinth as per detailed specifications and drawings or as directed including the stones to be set in the work as received from the quarry, after merely knocking offweak corners and edges with the masons hammer,the stones shall be carefully laid so as to break joints, no joint shall exceed 12.5 mm. (½″) in thickness, every stone shall be set flush in mortar, the face stone shall be for greater size, and good beds, one through stone shall be inserted at least every 0.80 sq. mete (1 square yard), the joints shall be racked out carefully at least 25 mm. (1″) where pointing or plastering tobe done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, bailing out water, watering and all exposed masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. 23 Providingandfixing StonePaving, First Sortinlimemortar1:1,withsizeof stone0.45 mtx 0.30mt.x0.15 mt.,asperdetailedspecificationsanddrawingsorasdirectedincludingallstoneslabstoof approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stones to be laid with joints not exceeding6 mm.(¼″)thickandtobeevenlyandfirmlybeddedflushinmortarontheconcreteandno hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all paving work when handed over to be perfectly clean and free from all mortar stains etc. complete. 24 Providing and fixing Stone Paving, SecondSort in lime 1:1/2 mortar, with average size of stone 0.45 m. x 0.30 m. x 0.15m. as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stonestobelaidwithjointsnotexceeding 6mm.(¼″)thick andtobe evenlyandfirmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all pavingwork when handed over to be perfectly clean and free from all mortar stains etc. complete.flooring for ghat and parking NON SSR R.A. No.151 25 Providing/Re-setting Ashlar Fine Stone Steps of reuse-stones in lime mortar 1:1 as per detailed specifications and drawings or as directed including each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A No.62 26 Providing Ashlar Fine Stone Steps of trap / granite stones in lime mortar 1:1with size of stone 0.6m. x 0.400 m. x 0.220 m. as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the stones shall be of exact size and shape, the shall be fine dressed on exposed surface, holes for balusters should be cut in the steps before they are laid, each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.61 27 Providing Ashlar Rough Tooled Masonry of trap / granite stones in lime mortar 1:1 with size of stone 0.60 m. x 0.45 m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″) in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No15 28 Providing/Re-setting Ashlar Fine Masonry of reuse-stones in lime mortar 1:1 in superstructure as per detailed specifications and drawings or as directed including the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course, the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A No.12 29 Providing Ashlar Fine Masonry of trap / granite stones for Galtha in lime mortar 1:1 with average size of stone 0.30m. x 0.70m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. completeFor Stone curved shape chajjafor Temple. NON SSR 11 30 Providing Ashlar Fine Masonry of trap / granite stones for BRACKET in lime mortar 1:1 with average size of stone 0.70 m. x 0.70 m. x 0.30 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 31 Providing Ashlar Fine Masonry of trap / granite stones for Parapet in lime mortar 1:1 with average size of stone 0.60 m. x 0.60 m. x 0.45 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete NON SSR 11 32 Providing Semi-circular Coping Cut-stone Second Sort, 22.5 cm. (9″) height and 52.5 cm. (1ꞌ9″) wide of trap / granite stones in lime mortar 1:1½ with size of stone0.762 m. x 0.560m. x 0.2 m. as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the stone shall be dressed full or to template, exposed face of the stones shall be fine rough tooled, semi-circular and all joints shall be in line and close and not more than 3 mm. (⅛″) thick, preparing the lime mortar in lime miller, scaffolding, watering and all coping work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 59 33 Providing Soil Bag Support to the monument with contractor´s soil in proper layers carefully as directed by Engineer in-charge including filling, tying and conveying the bags, removing the soil bags after work up to a distance of 50 meter beyond the monument area and cleaning the site etc. complete. For Lowering Down 34 Providing Soil Bag Support to the monument with contractor´s soil in proper layers carefully as directed by Engineer in-charge including filling, tying and conveying the bags, removing the soil bags after work up to a distance of 50 meter beyond the monument area and cleaning the site etc. complete.For Restoring 35 Providing Brick Masonry Second Class in superstructure of first quality bricks of size 9″ x 4½″ x 2½″ in lime mortar 1:1½,asperdetailedspecificationsanddrawingsorasdirectedincludingthebrickstobeofuniformsize, moulded on tables, thoroughly well burnt and sound, ringing clearly when stuck with trowel, the bricks to be soaked in water for 12 hours before used, the bricks are to be laid flush in mortar in such bond as directed, as far as possible, bricks of uniform colour are to be selected for the face work when it is not to be plastered, the joints arenot toexceed9.5 mm.(⅜″), nobats or half brick tobe usedin thework, rackingout joints where pointing or plastering to be done, striking joints where no pointing or plastering is to be done, preparingthe lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. 36 Providing Lime Pointing to stone work in lime mortar 1:1 in superstructure, as per detailed specifications and drawings or as directed including all face or visible work shall be pointed, unless otherwise specified and shall be done while the mortar is fresh, the mortar shall consists of lime and fine sand shall not be ground fine but sand should be finer, the joints of the pointed work shall be neatly defined by the pointing, the lines shall be regular and uniform in breadth and the joints shall be raised or flat as may directed, preparing the lime mortar with 640 gram pulp of wood apple (Belfruit) per cubic metre of lime mortar as a bonding material, scaffolding, watering andall workwhenhandedover tobeperfectlycleanandfreefromallmortar stainsetc.complete. 37 Carving ornamental work including moulding, grove, chisseling & dresing the same part with fine finishing as per existing/similar type of work of on the stone surface of any type & size or as directed by engineer in charge etc. complete. The charges for chisscling & dressing on stone surface for govering at the stone surface after chisling a fine surface rate for as per market rate. 38 Caving ornamental work on surface including moulding, grove, chisseling & dresing the same part with fine finishing as per existing/similar type of work of on the stone surface of any type & size or as directed by engineer in charge etc. complete.The charges for chiseling & dressing on stone surface for ornamental carving work surface etc. as per existing design. pattern and form as directed by engineer in charge Rates as per R.A. No. 29 39 Providing 12mm thick Rough Cast lime Plaster in single coat in lime mortar1.50:1 insuperstructure as per detailedspecifications anddrawings or as directedincludingall joints inmasonaryandbrickwork are tobe racked out to a depth of at atleast 20 mm and the wall to be washed with fresh water and thoroughly wetted for six hours before plastering,the plaster to be applied in an even and uniform coat well pressed in to the joints andtobewellbeatenfor11/2dayswithhandtappers,theplastershouldalsobewellsprinkleduringthe process of beating with mixture 1.10 kg jaggeryand 640 gram pulp of wood apple (Belfruit) in 90 to 135 litre of water the plaster being wetted occasionally with fresh water while beating is in progress all exposed angles and drawn neat clean and level soffits of arches must true arch of circle preparing the lime mortor in lime miller with 1.60 kg gugal (a king of fragnent gum) and 960 gram chopped hemp (fibre of bhendi or tag)per cubic meter of lime mortar as bonding material,of lime as a bonding material ,scaffolding watering and all work when handed over to be perfectely clean and free from all mortar stains etc complete 40 Providing10mm.thickRoughCastLimePlasterinsinglecoatinlimemortar1:1insuperstructure,asper detailedspecificationsanddrawingsorasdirectedincludingalljointsinmasonryandbrickworkaretobe racked out to a depth of at least 20 mm. and the wall to be washed with fresh water and thoroughly wetted for six hours before plastering, the plaster to be applied in an even and uniform coat well pressed in to the joints and to be well beaten for 1½ days with hand tappers, the plaster should also be well sprinkle during the proses of beating with a mixture of 1.10 kg Jaggary and 640 gram pulp of wood apple (Belfruit) in90 to135 litreof water, the plaster being wetted occasionally with fresh water while the beating is in progress, all exposed angles andjunctionswithdoorframetobecarefullyfinished,allmouldingsshallbeworkedtruetotemplateand drawn neat, clean and level, soffits of arches must true arch of circle, preparing the lime mortar in lime miller with1.60 kgGugal (akindof fragrant gum) and960 gramchoppedhemp(fibreof bhendior jute) percubic metre of lime mortar as a bonding material, of lime as a bonding material, scaffolding, watering and all work when handed over to be perfectly clean and free from all mortar stains etc. complete. 41 ProvidingFineCoatoflimeoverroughCastPlasterinsuperstructureasperdetailedspecificationsand drawings or as directed including all finishing Coat is to be applied overrough Cast Plaste and well polished with trowel,preparing lime mortar,Scaffolding,and watering complete 42 Providing and grouting the holes with Lime and Fine Screened Sand Slurry in proportion of (1:1)with proper jet pressure including Cleaning and Washing and Packing the existing Crack/Holes in the Brick or Stone masonary with lime and finesand paste in proportion of (1:1) properly from downside,filling the slurry in cracks or holes including all necesarry actions and required tools and machinaries,Scaffolding,Curing etc Complete. 43 Providing Ashlar Fine Masonry of trap / granite stones for TADKHADA(BASESTONE) in lime mortar 1:1 with average size of stone 0.60 m. x 0.60 m. x 0.60 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. completeFor Stone curved shape chajja for Temple. NON SSR 11 44 Providing and fixing First Quality Indian T.W Column of size 0.24 m x 0.24m x 2.20 m for roofing/ floor including carving as per drawing or as directed and scaffolding if necessary etc. complete.It is mandatory to use first quality well seasoned Indian Teak Wood from Forest Departments FDCML 45 Providing and fixing First Quality Indian T.W beams and truss parts of size 0.240 m x 0.280 m x 2.20 m for roofing/ floorincluding scaffolding if necessary etc. complete.It is mandatory to use first quality well seasoned Indian Teak Wood from Forest Departments FDCML 46 Providing and fixing First Quality Indian T.W Purlin and Rafter of size 0.150m x 0.150m x 4.25 m for roofing/ floorincluding scaffolding if necessary etc. complete.It is mandatory to use first quality well seasoned Indian Teak Wood from Forest Departments FDCML 47 Providing and fixing Burma T.W Inclined support part of Truss of size 0.15 m x 0.15 m x 2.5 m for roofing/ floorincluding scaffolding if necessary etc. complete.It is mandatory to use first quality well seasoned Indian Teak Wood from Forest Departments FDCML 48 Providing and fixing Burma T.W Arches of size 0.15m x 0.381 m x 1.8 m for roofing/ floorincluding including carving as per drawing or as directed and scaffolding if necessary etc. complete.It is mandatory to use first quality well seasoned Indian Teak Wood from Forest Departments FDCML 49 Providing and fixing Burma T.W Bracket of size 0.15m x 0.15 m x 0.9 m for roofing/ floorincluding including carving as per drawing or as directed and scaffolding if necessary etc. complete.It is mandatory to use first quality well seasoned Indian Teak Wood from Forest Departments FDCML 50 Providing and fixing Indian teak wood eaves boards 15 cm wide and 25 mm thick plain decorative type including including carving as per drawing or as directedand scaffolding and painting with two coats etc. complete.It is mandatory to use first quality well seasoned Indian Teak Wood from Forest Departments FDCML 51 Providing and fixing Indian teakwood plank ceiling 20mm thick plain under side tongued and grooved including iron screws, scaffolding, if necessary, including one primercoaton under side and one coat of coal tar on upper side etc. complete.It is mandatory to use first quality well seasoned Indian Teak Wood from Forest Departments FDCML 52 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side )profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) 53 Providing and fixing Mangalore tiled roofing with class AA tiles including securing thelast course of tiles near the eaves with steel flat 40 mm x 3 mm and 1.22 mm wire fixingcountry teak wood sloping battens of 25 x 12 mm teak wood horizontal battens of50mm x 25mm over the slopping battens, all iron work and coal tarring the battens etc.complete (Excluding ridge and hip tiles) 54 Providing and fixing Mangalore tile ridge and hip tiles of class AA including scaffolding if necessary, pointing with coloured cement mortar and curing etc. complete. 55 Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete 56 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete SSR 2022 - 23Page No.246 Item No.39.08 57 Providing and applying melamine polish of required finish to the wood work byspray machine including knotting and preparing the even surface by scraping,applying French polish , scaffolding if required etc. complete.Note:The work to be executed on prior approval of Superintending Engineer will be necessary. 58 Providingandlayingcastinsitu1:1:4LimeConcreteofbrokenbrickmetalforcopingor waterproofingasperdetailedspecificationsanddrawingsorasdirectedincludingcentring, formwork,laying/pumping,compacting,rougheningthemifspecialfinishistobeprovided, finishing if required, with fine aggregate, preparing the lime mortar in lime miller and then mixing withcoursedaggregateorsurkhi indrummixer,theconcretemustbebittenfortwodayswith pouring water as per specifications,scaffolding, wateringand all concrete work when handed over to be perfectly clean and free from all mortar stains, etc. complete. 59 Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in- charge, of approved brand and manufacture, diluted withsolventmineral Turpentineoil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sandstonemasonry surfacewith two or more coats to give uniform application of chemical onthe surface, all completeas per direction of Engineer-In-charge (The rate is inclusive of allmaterials& labours involved except scaffolding).Non - S.S.R. 60 Disposing of dismantling materials of R.C.C./ stone / brick masonry / derbies, excavated material / soil / murum/ rubbish material or vegetation / grass / shrubs etc., from work site beyond the 1 km. 61 Carrying of detailed topographic survey by using total station along the existing or new road including taking L-section and cross section at every 30 meter ROW ,taking at least 10 spot levels per cross section, picking up all existing details inside the Row like electric telephone line , encroachments, structures etc. connecting all the primary total station control points by G.I.S.Bench marks level or whichever available with department using auto level and preparing Auto CAD plan by using above data taking out 1 set of black and white printout on 50 micron polyster film sheet A2 size and 2 sets of coloured printout on A2 size submitting soft copy all data on CD. Plain Terrain New Alignment SSR 2022-23 Page No.17 Item No. 1.41 62 Public Seating Chair. - 3 Seater Providing and Fixing3seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 63 Preparing and carrying out videography, Documentary & Shooting of still photographs of Extra copies - 5 X 7 Sizeoutdoor and indoor of roads, bridges, other structures and programme, including preliminarys survey, still shots moving shooting, necessary board for video shooting hiring of vehicle, equipment for video shoot­ing, transportation of all equipment, persons, required for shooting, lighting arrangement as may be necessary, editing, mixing, titling, lettering, sounding including cost of coloured cassette of approved quality etc. completeNON SSR
Contract Date: Apr 20, 2026 Contract Value : 1.06 Crore
Government Departments No of Bidders 4
Maharashtra View Result →
37.
Tourism #10023424 AOC
Proposed Conservation And Repair Work To Kot Wall In Precinct From Ekmukhi Datta Mandir To Balaji Kot, At.Panchvati, Tq.Dist.Nashik- 1 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.SSR 2022-23Page No.299 Item No.46.42 2 Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete.SSR 2022-23Page No.298 Item No.46.38 3 G.I sheet (Patra) Partition: As per Instruction erect the vertical poles at a distance of 8 to 10 feet & on that provide the horizontal poles & prepare the square, on that fix the GI sheet (patra) .Provide the opening in patra where required. Instructions:- 1) In this work Excavation in any type of road, soil, loose or hard rock should be done and after the work Excavated pits should be refill. 2) The rate of the above work is for 3 days and because of if any reason days exceed beyond 3 days Rate as perfollowing will be given a) for 4th day to 30 th day- 3% of original rate.PMC(BHAVAN)DSR 2022-23, Item No.2998,AG 65.14 4 Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) SSR 2022-23Page No.85 Item No. 12.22 5 Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete.SSR 2022-23 Page No.157 Item No. 21.34 6 Removal of plants / ficus grown by pulling out root system embedded in masnory, cutting stem and application of high/gur/lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide Glycel(iso proplamine salt of glyphosate) or other chemical as specified by the Engineer incharge etc. complete.SSR 2022-23 Page No.301 Item No. 46.58 7 Specialised Stone cleaning to remove oil or emulsion paint,stains or dark patches,layers of impervious coatings,cementious layers,rust stains from surface of stone with chemicals ,thinners,solvents or soft teepol type soap solution or by pressure jet machine (As specified by consulting architect),A gentle use of air abrasive tools may be permitted as long as no damage to the original surface is ensured.it may include usage of mechanical tapping ,chemical surfactant or solvant,patent cleaning product or use of pressurised micro abrasive as necessary.test patches would need to be undertaken to asses efficeincy of technique prior to work.Removal to be followed by water washing.The surface shall finally be cleaned by hand rubbing and rinsing with clean water to obtain nearly original surface,colour and textureNON SSR R.A.34 8 Gently cleaning the surface of stone masonary with specialised water misting technique employing air water jet usinga fine nossle sprinkling system calibrated to sprey fine mist along the stone surface without over wetting followed up by gentle brushing with soft nylon brushesand removing dirt,dist,bird dropping,grease,oil,algae,fungus,monkey beats,vegetable growth,etc as specified.gentle surface cleaning using water misting and mild pH balanced surfactants as specified for indicated areas to remove the surface dirt,grit accretion by means of water misting and cleaning etc.complete as directed by engineer in chargeBMC -USOR-R3-CS-CH-1,2023 9 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete SSR 2022-23Page No. 297 Item No. 46.19 10 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directedinthe compound including scaffolding etc. complete.S.S.R. 2022 - 23 Page No.235,Item No.38.26 11 Removing wooden or A.C.partition including frame work and stack-ing the materials as with all leads, lifts etc. complete.SSR 2022-23Page No.296 Item No.46.17 12 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete S.S.R. 2022 - 23 Page No.296,Item No.46.12 13 Removing brick bat coba including stacking the spoils as directed with all leads,lifts etc, complete.SSR 2022-23Page No.296 Item No.46.14 14 Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete.S.S.R. 2022 - 23 Page No.211,Item No.32.33 15 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc S.S.R. 2022 - 23 Page No.296,Item No.46.09 16 Removing pointing and other epoxy-based hard material from joints and surface area of Basalt stone masonary manually with chisel and hammer or with the help of electric grinders wherever directed by Engineer In charge. Proper care should be taken not to damage the stone during removal. 17 Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc SSR 2022-23Page No.296 Item No.46.11 18 Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete.SSR 2022-23Page No.297 Item No.46.29 19 Numbering the monument elements in proper order before lowering down with approved colour and shade as directed by Engineer in-charge, including ladder, scaffolding etc.complete.NON SSR R.A No.203 20 Lowering down carefully existing stone masonry of the monument manually in proper order including shifting the stone elements up to a distance of 50 meter beyond the monument area and stacking them as directed by Engineer in-charge, removing building rubbish and cleaning the site etc. complete .NON SSR R.A No.204 21 Providing Lime Pointing to stone work in lime mortar 1:1 in superstructure, as per detailed specifications and drawings or as directed including all face or visible work shall be pointed, unless otherwisespecified and shall be done while the mortar is fresh, the mortar shall consists of lime and fine sandshall not be ground fine but sand should be finer, the joints of the pointed work shall be neatlydefined by the pointing, the lines shall be regular and uniform in breadth and the joints shall beraised or flat as may directed, preparing the lime mortar with 640 gram pulp of wood apple(Belfruit) per cubic metre of lime mortar as a bonding material, watering and all work whenhanded over to be perfectly clean and free from all mortar stains etc. complete Non - S.S.R. Item From Rate Analysis No. 136 of Deapartment Rate Abstract 22 Providing injectiongrouting with aslurryof lime and fine screened sand in proporation of (1 : 1) with a proper jet pump pressure including cleaning and washing and packing the existing crack / holes in the brick or stone masnoryproperly upward with slurry,scaffolding,curing etc. complete and machineries, scaffolding, curing etc. complete.Non S.S.R. 23 Excavation for foundation in earth, soils of all types sand, gravel and soft murum,Including removing the excavated matreial upto a distance of 50 M beyond the building area stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling ,ramming, watering Including shoring and strutting etc.complete ( Lift upto 1.50m ) SSR 2022-23Page No.153 Item No. 21.01 24 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. SSR 2022-23Page No.157 Item No. 21.40 25 Compacting the sub grade/gravel/oversize metal (200 mm loose) layers for all width with Vibratory roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete.SSR 2022-23Page No.346 Item No. 50.60 26 Providing and laying cast in situ 1:2:4 Lime Concrete of Trap stone metal for foundation and bedding as per detailed specifications and drawings or as directed including centring, formwork, laying/pumping, compacting, preparing the lime mortar in lime miller and then mixing with coursed aggregate in drum mixer, bailing out water, watering etc. complete.NON SSR R.A. No. 4 27 Providing Un-coursed Rubble Masonry of trap / granite stones in lime mortar 1:1½, in foundation and plinth as per detailed specifications and drawings or as directed including the stones to be set in the work as received from the quarry, after merely knocking off weak corners and edges with the masons hammer, the stones shall be carefully laid so as to break joints, no joint shall exceed 12.5 mm. (½″) in thickness, every stone shall be set flush in mortar, the face stone shall be for greater size, and good beds, one through stone shall be inserted at least every 0.80 sq. mete (1 square yard), the joints shall be racked out carefully at least 25 mm. (1″) where pointing or plastering to be done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, bailing out water, watering and all exposed masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete..(NON SSR R.A No.87) 28 Providing and fixing Stone Paving, SecondSort in lime 1:1/2 mortar, with average size of stone 0.45 m. x 0.60 m. x 0.15m. as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stonestobelaidwithjointsnotexceeding 6mm.(¼″)thick andtobe evenlyandfirmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all pavingwork when handed over to be perfectly clean and free from all mortar stains etc. complete.flooring for ghat and parking NON SSR R.A. No.151 29 Providing and fixing Stone Paving, First Sort in lime mortar 1:1, with size of stone 0.45 m. x 0.60 m. x 0.15 m., as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stones to be laid with joints not exceeding 6 mm. (¼″) thick and to be evenly and firmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all paving work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.149 30 Providing Ashlar Rough Tooled Masonry of trap / granite stones in lime mortar 1:1 with size of stone 0.60 m. x 0.45 m. x 0.23 m. in superstructure as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″) in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No15 31 Providing Brick Masonry Second Class in superstructure with size of brick9″ x 4½″ x 2½″ in lime mortar 1:1½, as per detailed specifications and drawings or as directed including the bricks to be of uniform size, moulded ground, thoroughly well burnt and sound, ringing clearly when stuck with trowel, the bricks to be soaked in water for 12 hours before used, the bricks are to be laid flush in mortar in suchbond as directed, as far as possible, bricks of uniform colour are to be selected for the face work when it is not to be plastered, the joints are not to exceed12.5 mm. (½″), no bats or half brick to be usedin the work, racking out joints where pointing or plastering tobe done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 119 32 Providing Ashlar Arching of trap / granite stones in lime mortar 1:1, with size of stone 60 cm. x 45 cm. x 30 cm. as per detailed specifications and drawings or as directed including the arch stones be of approved quality, colour, hard and free from defect of any kind, the arch stones in all cases of the entire thickness, the arch stones shall be dressed full and true to their proper shapes with the necessary summering, twist or winding and be set in fine mortar, the intrados, joints and beds to fair tooled and left full, the cast or keying course to be accurately fitted, at all horizontal joints the intrados to have a 2 cm. (¾″) chamfer, the face stone may be tooled or rock-faced with or without chamfer as directed, in arches up to 60 cm. (2ꞌ) in depth all stones shall be of the full thickness of the ring, arches to be built on proper centring, the bed joints shall be radial and the side joints shall be at right angles to the bed joints and the thickness of the joints shall not exceed 5 mm. (3/16″) preparing the lime mortar in lime miller, cantering/scaffolding, watering and all archwork when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No125 33 Providing/Re-setting Ashlar Fine Stone Steps of reuse-stones in lime mortar 1:1 as per detailed specifications and drawings or as directed including each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A No.62 34 Providing Ashlar Fine Stone Steps of trap / granite stones in lime mortar 1:1with size of stone 0.6m. x 0.400 m. x 0.220 m. as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the stones shall be of exact size and shape, the shall be fine dressed on exposed surface, holes for balusters should be cut in the steps before they are laid, each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR R.A. No.61 35 Providing Semi-circular Coping Cut-stone Second Sort, 22.5 cm. (9″) height and 52.5 cm. (1ꞌ9″) wide of trap / granite stones in lime mortar 1:1½ with size of stone0.60 m. x 0.60m. x 0.200 m. as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the stone shall be dressed full or to template, exposed face of the stones shall be fine rough tooled, semi-circular and all joints shall be in line and close and not more than 3 mm. (⅛″) thick, preparing the lime mortar in lime miller, scaffolding, watering and all coping work when handed over to be perfectly clean and free from all mortar stains etc. complete. NON SSR 59 36 Providing and fixing 50mm diameter and 1.5 mm thick vertical and top Stainless steel hand railing in S.S.304 Grade with Stainless steel square / circular pipe bracing of size 32mm x32mm x1.5 mm in 3 rows including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete SSR 2022-23Page No.379 Item No. 51.111 37 Providing Soil Bag Support to the monument with contractor´s soil in proper layers carefully as directed by Engineer in-charge including filling, tying and conveying the bags, removing the soil bags after work up to a distance of 50 meter beyond the monument area and cleaning the site etc. complete.NONSSR206 38 Providing and laying cast in situ 1:1:4 Lime Concrete of broken brick metal for coping or waterproofing as per detailed specifications and drawings or as directed including centring, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required, with fine aggregate, preparing the lime mortar in lime miller and then mixing with coursed aggregate or surkhi in drum mixer, the concrete must be bitten for two days with pouring water as per specifications, scaffolding, watering and all concrete work when handed over to be perfectly clean and free from all mortar stains, etc. complete. NON S.S.R. R.A.6 39 Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical: 12 Part of Turpentine oil), on the existing Basalt stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 40 Providing12 mm. thick Rough Cast Lime Plaster and 10 mm thick in doublecoat in lime mortar 1:1/2in plinth, as perdetailedspecificationsanddrawingsorasdirectedincludingalljointsinmasonryandbrick work are to be racked out to a depth of at least 20 mm. and the wall to be washed with fresh water andthoroughlywettedforsixhoursbeforeplastering,theplastertobeappliedinanevenand uniform coat well pressed in to the joints and to be well beaten for 1½ days with hand tappers, the plaster should also be well sprinkle during the proses of beating with a mixture of 1.10 jaggary and 640grampulpofwoodapple(Belfruit)in90to135litreofwater,theplasterbeingwetted occasionally with fresh water while the beating is in progress, all exposed angles and junctions with door frame to be carefully finished, all mouldings shall be worked true to template and drawn neat, clean and level, soffits of arches must true arch of circle, preparing the lime mortar in lime miller with 1.60 kg Gugal (a kind of fragrant gum) and 960 gram chopped hemp (fibre of bhendi or tag ) per cubic metre of lime mortar as a bonding material, of lime as a bonding material, watering and allwork when handed over to be perfectly clean and free from all mortar stains etc. complete.NONSSR RA142 41 Stucco work in lime, surkhi and sand (1:1:1) as per traditional practices and design, the mortar should be prepared by grinding mill only. The thickness varies from 10mm to 100mm as per design.NON SSR 2022 - 23 42 Providing and applying integral fine coat, with addition of colour pigments, as paint to the plainlime stucco plaster in 2 layers, including scaffolding, curing, all leads and lifts, etc. complete. 1) The first coat to be laid is a mixture of fine lime and white washing lime in proportion of 2:1,made smooth with wooden rubbers and very lightly beaten. 2)The finishing coat consisting of fine lime, white washing lime, mixed with the appropriate pigment in 1:2:1 proportion is to be applied and well polished with trowels. .NON SSR 2022 - 23 43 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailingout water, Steel centering formwork, laying/pumping cover blocks, compaction andcuring roughening the surface if special finish is to be provided (Excluding reinforcementand structural steel) etc. complete, with fully automatic micro processor based PLC withSCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.complete. With fine aggregate (Crushed sand VSI Grade)SSR 2022 - 23Page No.178 Item No.25.11 44 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap /granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing oras directed including steel centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness togive a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)SSR 2022 - 23Page No.179 Item No.25.31 45 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, complete.SSR-2022-23 Item.No.26.33 Pg. No.188 46 Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt.SSR 2022 - 23Page No.294 Item No.44.10 47 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. SSR 2022-23Item No. 32.12,Page No.209 48 Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge). S.S.R. 2022 - 23 Page No. 409,Item No.51.192 49 Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete SSR 2022 - 23Page No.245 Item No.39.01 50 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete SSR 2022 - 23Page No.246 Item No.39.08 51 Providing and applying melamine polish of required finish to the wood work byspray machine including knotting and preparing the even surface by scraping,applying French polish , scaffolding if required etc. complete.Note:The work to be executed on prior approval of Superintending Engineer will be necessary.SSR 2022 - 23Page No.222 Item No.34.09 52 Disposing of dismantling materials of R.C.C./ stone / brick masonry / derbies, excavated material / soil / murum / rubbish material or vegetation / grass / shrubs etc., from work site beyond the 5km. SSR 2023-24STATEMENT C1 PG NO.459 53 Public Seating Chair. - 3 Seater Providing and Fixing 3seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.SSR 2022-23Page No.359 Item No.51.44 54 Preparing and carrying out videography, Documentary & Shooting of still photographs of Extra copies - 5 X 7 Sizeoutdoor and indoor of roads, bridges, other structures and programme, including preliminarys survey, still shots moving shooting, necessary board for video shooting hiring of vehicle, equipment for video shoot­ing, transportation of all equipment, persons, required for shooting, lighting arrangement as may be necessary, editing, mixing, titling, lettering, sounding including cost of coloured cassette of approved quality etc. completeNON SSR 55 Book Designing, Publishing and Printing: The work involves printing of a book / guidebook on the fort / monuments and its various aspects, which would provide authentic and precise tourism oriented information. This work involves important photographsof the site, art objects, antiquities, inscriptions etc., which would be useful for educating the masses of the rich cultural heritage of the site, region and state. providing 100 pages coloured books as directed by engineer in charge / ADA Non SSR 56 Carrying of detailed topographic survey by using total station along the existing or new road including taking L-section and cross section at every 30 meter ROW ,taking at least 10 spot levels per cross section, picking up all existing details inside the Row like electric telephone line , encroachments, structures etc. connecting all the primary total station control points by G.I.S.Bench marks level or whichever available with department using auto level and preparing Auto CAD plan by using above data taking out 1 set of black and white printout on 50 micron polyster film sheet A2 size and 2 sets of coloured printout on A2 size submitting soft copy all data on CD. Plain Terrain New Alignment SSR 2022-23Page No.17 Item No.1.41 57 Providing and fixing of retro-reflectorised informatory sign board rectangular /Square in shape having area greater than 0.9 square meter made out of 2mm aluminum sheet bonded withwhite retroreflective sheeting of Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive / heat activated adhesive retoreflective specified background, border and backside reto reflctive symbols,letters, numerals, arrowasper IRC:67-2012TableNo8.3, supported with back support frame25mmx25mmx3mm,duly painted on back side with two coats of grey stove enamel paint and supported on one Number mild steel angle iron post 75mmx75mmx6mm,3.5mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45cmx45cmx60cm,60cm below ground level asper approveddrawingTheangle ironpost shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paint having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete. The nut bolts of board with angle iron post / supportingstructureafter fixingat sitehas tobeelectrically welded.ClassB(TypeIVHighintensitymicro-prismaticgrade sheeting-HIP) sheeting shall have7 yearswrittenwarranty fromthemanufacturerandauthoriseddistributor / convertor issued for field performance including the screen printed areasandcut-out sheetingandcut-out durable transparent overlay film and this warrantySSR 2022 - 23Page No.58 Item No.6.34
Contract Date: Apr 20, 2026 Contract Value : 3.98 Crore
Government Departments No of Bidders 2
Maharashtra View Result →
38.
Housing Urban and Rular Development #9966229 AOC
Misc. Works At Cottage No 11 And 12 In The Premises Of Nagbhavan ,Nagpur. (Only For Unemployed Engineers).-1 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. 2 Removing W.C. pansin including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials sadn where directed including throwing the unserviceable materials ls outside etc.carefully and throwing out there refusal outside etc. complete. 3 Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 meters or spreading in the compound and cleaning the site etc. complete. 4 Removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completed 5 Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the un serviceable materials outside etc complete. 6 Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and make to doorshutterincludingremovingexistingthesameinoriginalpositionmakingproper adjustment for smoothoperation etc. Complete as per sample approved by Engineer in-charge. 7 Providing andfixing 450mm x550mm size superiortype Belgium mirrorwith16mmdia. nickel plated towel rod etc. complete. 8 Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. 9 Providing and fixing Bib cock with wall flange (Angular Shape) in wall surface including all labor and material cost of Jaguar Brand ets.complete.As directed by Engineer Incharge 10 Providing andfixing 10cm C.I.NahaniTrapincludingC.I.gratingbendandpiece ofC.I. pipe upto the outside face of the wall complete. 11 Providing andfixing onwalls/ceiling/floor 20mm dia.CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 12 Providing , laying and fixing ,jointingEco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such as a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. 13 Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8C.Cfoundation,1:2:4C.C.channels/halfroundglazedstonewarepipechannel,salt glazedstone-wareinterceptingtrapwithroddingpipesetin1:4:8cementconcreteblock,brickmasonryplasteringinsideandOutside,fixedincementconcretewithR.C.C.Cover medium duty 140 Kilogram. etc complete 14 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 Kilogram) 15 Providing and fixingTable top white wash basin of size 120x635x405mm rubber plugs and brass chain, withpillar cock, C.P.Angular stop cock long thread, continentalincluding S.S. bottle trap of approved make having necessary pipe connection up to the outside face of the wall.etc complete as directed by Engineer in charge. 16 Providing andfixing white europeantype wall-hung pan, of size 350mm x355mm x570 mmconcealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe uptotheoutsidefaceofwall,100mmdiaC.I.plugbendinletpipeallfittings,cutting& making good walls, floors etc. complete. 17 Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalentmake including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturers Green product and shall got approved from the Engineer In Charge.) 18 Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. 19 Manually clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for proper functioning line chamber to chamber etc. complete. 20 Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. 21 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium platedfixturesandfastenings,withbrassmortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete. 22 Providingandapplyingmelaminepolishofrequiredfinishtothewoodworkbyspray machineincludingknottingandpreparingtheevensurfacebyscraping,applyingFrench polish , scaffolding if required etc. complete. 23 Providing andfixing in position(as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeofbearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre.Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm atweight 0.417Kilogram/Runningmetre.Asperdetaileddrawingsandasdirectedby Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainlesssteeljailwithall required screws and nuts etc, complete. With colour Anodising with box 24 Providing and fixing in position powder coated aluminium louvered windows / ventilator of varioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete. 25 Providing and fixing fly proof mesh shutter toventilator / window using CCTW members of size 45 x22 mm for frame work and35 x 22 mm for middle support andfixing fly proof mesh on it and coveringTW battens of size 20 x 10 mm including priming and two coats of oil painting to the new wood and steel work and all labour charges including all fixture and fastenings etc. complete 26 Providing antitermite treatment around the periphery of the existing building as per I.S. 6313 (Part-III) by excavating trenches of 20cm width and exposing the sides of columns and plinth beams upto a depth of 300mm and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per One Running Metre and refilling the trenches etc. complete covering 2 years guarantee on bond paper. 27 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 28 Providing and laying vitrified rustic matt stone finish tileshaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approvedmake,shadeandpatternforflooringinrequiredpositionlaid onabedof1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 29 Providing and laying vitrified rustic matt stone finish tileshaving size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approvedmake,shadeandpatternfordadoandskirtinginrequiredpositionfixedin1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. 30 Providing and laying ceramic tileshaving size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 31 Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S.for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 32 ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade) 33 Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles forsteps and dado of approved colour and design 22 +/ -2 mm thick bayercolourpigmentedasperIS1237-1980reaffirmedin2006,havingwerttransvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing,polished and cleaning etc. complete. For steps, and dado 34 ProvidingandfixingP.V.C.Rainwaterpipesof160mmouterdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. 35 Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) 36 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asperdetaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixinginpositionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding one coat of anticorrosive paint andover ittwo coats of oil painting of approved quality and shade etc. complete. 37 Providing and fixing superior quality decorative type wall paper etc.complete. 38 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 39 Providing andapplying one coatofsealcementprimerofapprovedmanufacture andshed includingscaffoldingpreparingthesurfacebycleaningdirtandotherforeignmatters, scrapping if necessary including scaffolding etc. complete. 40 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in single coat including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. 41 Providing and applying One coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat,scaffolding if necessary , and watering the surface for two days etc complete. 42 Providing and applying two coats of flat oil paint of approved colour to the old structural steel workandironworkpreviouslypaintedinbuildingincludingscaffolding,ifnecessary, cleaning and preparing the surface (excluding primer coat)etc. complete. 43 Transportation of material obtained from debris of various sorts excavated stuff including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed.( Beyond 10 Km. ) 44 Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction material for which royalty is necessary. Natural Sand 45 Testing Charges for Conducting BASIC TEST OF CEMENT.Standard ConsistancyFineness, Specific Gravity,Setting Time ( Initial & Final ), CompressiveStrength, Soundness etc. complete. 46 Testing Charges for Conducting BASIC TEST OF FINE AGGREGATES. Fineness Modulus ( Sieve Analysis ),Silt & Clay Content 47 Testing Charges for Conducting BASIC TEST Of CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles)
Contract Date: Apr 10, 2026 Contract Value : 5.57 Lakh
Government Departments No of Bidders 9
Maharashtra View Result →
39.
Housing Urban and Rular Development #9966228 AOC
Misc. Works At Cottage No 15 And 16 In The Premises Of Nagbhavan ,Nagpur. (Only For Unemployed Engineers).-1 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. 2 Removing W.C.pans in including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stackingtheserviceablematerialssadnwheredirectedincludingthrowingtheunserviceablematerialslsoutsideetc.carefullyandthrowingoutthererefusaloutsideetc. complete. 3 Removingtheexistingcementplasterofanythicknesswithoutcausingdustnuisanceand stacking the debris upto a distance of 50 meters or spreading in the compound and cleaning the site etc. complete. 4 Removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completed 5 Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the un serviceable materials outside etc complete. 6 Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and make to doorshutterincludingremovingexistingthesameinoriginalpositionmakingproper adjustment for smoothoperation etc. Complete as per sample approved by Engineer in-charge. 7 Providing andfixing 450mm x550mm size superiortype Belgium mirrorwith16mmdia. nickel plated towel rod etc. complete. 8 Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. 9 Providing and fixing Bib cock with wall flange (Angular Shape) in wall surface including all labor and material cost of Jaguar Brand ets.complete.As directed by Engineer Incharge 10 Providing andfixing 10cm C.I.NahaniTrapincludingC.I.gratingbendandpiece ofC.I. pipe upto the outside face of the wall complete. 11 Providing andfixing onwalls/ceiling/floor 20mm dia.CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 12 Providing , laying and fixing ,jointingEco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such as a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. 13 Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8C.Cfoundation,1:2:4C.C.channels/halfroundglazedstonewarepipechannel,salt glazedstone-wareinterceptingtrapwithroddingpipesetin1:4:8cementconcreteblock,brickmasonryplasteringinsideandOutside,fixedincementconcretewithR.C.C.Cover medium duty 140 Kilogram. etc complete 14 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 Kilogram) 15 Providing and fixingTable top white wash basin of size 120x635x405mm rubber plugs and brass chain, withpillar cock, C.P.Angular stop cock long thread, continentalincluding S.S. bottle trap of approved make having necessary pipe connection up to the outside face of the wall.etc complete as directed by Engineer in charge. 16 Providing andfixing white europeantype wall-hung pan, of size 350mm x355mm x570 mmconcealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe uptotheoutsidefaceofwall,100mmdiaC.I.plugbendinletpipeallfittings,cutting& making good walls, floors etc. complete. 17 Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalentmake including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturers Green product and shall got approved from the Engineer In Charge.) 18 Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. 19 Manually clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for proper functioning line chamber to chamber etc. complete. 20 Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. 21 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both f Send feedback Use the arrows to see the full translation. 22 Providingandapplyingmelaminepolishofrequiredfinishtothewoodworkbyspray machineincludingknottingandpreparingtheevensurfacebyscraping,applyingFrench polish , scaffolding if required etc. complete. 23 Providing andfixing in position(as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeofbearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre.Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm atweight 0.417Kilogram/Runningmetre.Asperdetaileddrawingsandasdirectedby Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainlesssteeljailwithall required screws and nuts etc, complete. With colour Anodising with box 24 Providing and fixing in position powder coated aluminium louvered windows / ventilator of varioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete. 25 Providing and fixing fly proof mesh shutter toventilator / window using CCTW members of size 45 x22 mm for frame work and35 x 22 mm for middle support andfixing fly proof mesh on it and coveringTW battens of size 20 x 10 mm including priming and two coats of oil painting to the new wood and steel work and all labour charges including all fixture and fastenings etc. complete 26 Providing antitermite treatment around the periphery of the existing building as per I.S. 6313 (Part-III) by excavating trenches of 20cm width and exposing the sides of columns and plinth beams upto a depth of 300mm and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per One Running Metre and refilling the trenches etc. complete covering 2 years guarantee on bond paper. 27 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 28 Providing and laying vitrified rustic matt stone finish tileshaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approvedmake,shadeandpatternforflooringinrequiredpositionlaid onabedof1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 29 Providing and laying vitrified rustic matt stone finish tileshaving size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approvedmake,shadeandpatternfordadoandskirtinginrequiredpositionfixedin1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. 30 Providing and laying ceramic tileshaving size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 31 Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S.for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 32 ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade) 33 Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles forsteps and dado of approved colour and design 22 +/ -2 mm thick bayercolourpigmentedasperIS1237-1980reaffirmedin2006,havingwerttransvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing,polished and cleaning etc. complete. For steps, and dado 34 ProvidingandfixingP.V.C.Rainwaterpipesof160mmouterdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. 35 Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) 36 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asperdetaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixinginpositionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding one coat of anticorrosive paint andover ittwo coats of oil painting of approved quality and shade etc. complete. 37 Providing and fixing superior quality decorative type wall paper etc.complete. 38 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 39 Providing andapplying one coatofsealcementprimerofapprovedmanufacture andshed includingscaffoldingpreparingthesurfacebycleaningdirtandotherforeignmatters, scrapping if necessary including scaffolding etc. complete. 40 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in single coat including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. 41 Providing and applying One coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat,scaffolding if necessary , and watering the surface for two days etc complete. 42 Providing and applying two coats of flat oil paint of approved colour to the old structural steel workandironworkpreviouslypaintedinbuildingincludingscaffolding,ifnecessary, cleaning and preparing the surface (excluding primer coat)etc. complete. 43 Transportation of material obtained from debris of various sorts excavated stuff including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed.( Beyond 10 Km. ) 44 Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction material for which royalty is necessary. Natural Sand 45 Testing Charges for Conducting BASIC TEST OF CEMENT.Standard ConsistancyFineness, Specific Gravity,Setting Time ( Initial & Final ), CompressiveStrength, Soundness etc. complete. 46 Testing Charges for Conducting BASIC TEST OF FINE AGGREGATES. Fineness Modulus ( Sieve Analysis ),Silt & Clay Content 47 Testing Charges for Conducting BASIC TEST Of CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles)
Contract Date: Apr 10, 2026 Contract Value : 5.57 Lakh
Government Departments No of Bidders 8
Maharashtra View Result →
40.
Educational and Research Institute #9946716 Technical Bid
Tender For Sale Of Unserviceable Material In Mpbse Bhopal; 1- Aluminium Profile material such as Aluminium Partition frame, Alu. Grill, Alu. Window Frame, Alu. Door Frame, Alu. Cabinate Kg. 2- Steel Structure material such as Windows, Door, Grill, Cleat angle & all type Steel material. Kg. Telephone Instrument/Plan Each 406 2 Card less Phone Each 11 3 Mobile Instrument Each 13 4 Modam Each 36 5 All Parpus/Table Fan/Pedistal fan/Wall Bracket fan Each 121 6 Window A/C Each 58 7 Flood light/Helogen Fitting Each 58 8 Tube Fitting 2x40/Decorutive Tube fitting 1x40/Miror Optica/ T-5 Each 1054 9 Air Cloor Each 200 10 Emeargency Light Each 61 11 Fire Extingusher ABC Type/Co2/Dcp Each 36 12 Automatic fire Extingusher 10kg Each 1 13 Fax Machine Each 18 14 Genrator Each 3 15 Heat Convector Each 24 16 Alu. Ladder Each 4 17 Street Light Each 132 18 Refrigerator Each 3 19 Stablizer Each 19 20 Table lamp Each 4 21 Water cooler storag/ Water Cooler Cumpurifire Each 41 22 Aquagard Each 5 23 UPS Off Line Each 35 24 UPS On Line Each 15 25 Volumina Fitting 150 w Each 5 26 Celling fan Each 400 27 Split type A/C Each 28 28 Geyser Each 52 29 CPC Cord Each 16 30 Fresh air fan/Exhaust fan Each 70 31 Submersiwal Pump Each 2 32 Pump set/Monoblock/centrifugal Each 5 33 TV Each 10 34 Mic Each 10 35 Inverter Each 9 36 CCTV System - Camera/ DVR Each 1 37 Dome Camera with Housing Each 5 38 Electric Distribution Panel Each 2 39 Chang over 800 A Each 2 40 PBAX Exchang Make- BPL Each 1 41 Fitting 11 Watt Each 44 42 Fitting 18 Watt Each 1 43 Fitting 8 Watt Each 2 44 Projector Each 2 45 Light Fitting 2x2 Each 22 46 Light Fitting 1x1 Each 3 47 Amplifier Each 2 48 Distroyer Each 1 49 Speekar Each 8 50 Hand Dryer Each 6 51 Mixer Each 1 52 Motorize Screen Each 1 1- All type Wooden Material Such as Door, Windows & other wooden material 2- Useless Electrical maintenance materials and T&P of main administrative building campus and Ravishankar nagar : - Tube road, choke, starter, holder, lampe, fuse switch, socket, board, regulator, condenser, wire, cable, busbar, MCB, MCB box, bell, pipe, main switch, celling rose, pump starter, power pluge, Modem, Energy Meter, Smoke Detector, Post top lenturn ,etc.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Madhya Pradesh View Result →
41.
Housing Urban and Rular Development #9943596 AOC
Tender For Renovation And Upgradation Works Of Govt. Residential Qtr No. E-5 At Senior Officers Colony, Khanapara, Guwahati-22 , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. All Kinds Of Soil , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Cement Plaster 1:3 (1 Cement: 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement. 20 Mm Cement Plaster , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Providing And Fixing Roofing Consist Of 0.8 Mm Thick Galvanized Steel Deck Sheet Confirming To Is 277:1992 Used As Permanent Shuttering Over Which Ms Wire Mesh 3Mm Laid At 100X100 Mm Grid Including Edge Trim Covered With Concrete. This Metal Deck Will Be Supported On Structural Steel Beam With Shear Studs. (Structural Steel Like Beam,Column, Joists Etc. & Concrete Of Different Grade As Per Design Will Be Paid Separately). , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting,Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. Kg 89.65 , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Second Class Teak Wood , Providing And Fixing Bright Finished Brass Single Acting Spring Hinges With Necessary Brass Screws Etc. Complete : 150 Mm , Providing And Fixing Factory Made Laminated Veneer Lumber Glazed Shutter Conforming To Is: 14616 And Tads 15:2001 (Part B), Using 4 Mm Thick Float Glass Panes For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, All As Per Directions Of Engineer-In-Charge (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) 30 Mm Thick Shutters , Extra For Providing Frosted Glass Panes 4 Mm Thick Instead Of Ordinary Float Glass Panes 4 Mm Thick In Doors, Windows And Clerestory Window Shutters. (Area Of Opening For Glass Panes Excluding Portion Inside Rebate Shall Be Measured). , Polishing In High Gloss/Matt Finish Melamine Clear Polish On Wood Work In Required Color/Wooden Shade Texture With Following Process In The Sequence As Detailed Below: 1. The Surface To Be Polished Is Rubbed With Sand Paper 80/120 No.And Then With Sand Paper Of 160/180 Nos. 2. Applying Two Coats Of Sealer With Spray Gun And Allowing Sufficient Drying Time For 1St Coat And 2Nd Coat Is Allowed To Dry For 8 To 12Hrs. 3. On Drying Of Sealer Coat, Wet Rubbing With Emery Cloth Of Finer Grading With Ample Water To Remove Excess Sealer Layer And Make The Surface Further Smooth After This Wet Rubbing, Then Surface Is Applied With Special Grade Melamine Fillers To Fill All The Small And Big Holes/Grooves Etc. Filler Coat To Be Allowed To Dry For 4 To 6 Hrs On Which Again A Light Wet Rubbing Is Done This Surface Is Further Allowed To Dry For 12 Hrs. 4. On This, 1St Coat Of Melamine Polish Is Applied With Spray Gun Using Melamine Clear Polish And Melamine Thinner In Required Proportion. This 1St Coat Is Allowed To Dry For 24 Hrs Then This Dry Surface Is Again Fine Wet Rubbed Smooth, Which Is Further Allowed To Dry For 12 Hrs. The Final Melamine Polish Is Applied With Compressor Pressure Spray Gun Using Melamine Clear Polish And Melamine Thinner Mixed In Required Proportion Complete As Per Direction Of Engineer-In-Charge. (Final Coat To Be Done In 1 Or 2 Layers Without Gap Of Time.) , Providing And Fixing Brass 100Mm Mortice Latch And Lock With 6 Nlevers Without Pair Of Handles (Best Make Of Approved Quality) For Aluminium Doors Including Necessary Cutting And Making Good Etc.Complete. , Providing And Fixing Factory Made Upvc White Colour Casement/ Casement Cum Fixed Glazed Door Comprising Of Upvc Multi-Chambered Frame,Sash And Mullion (Where Ever Required) Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length (Shape & Size According To Upvc Profile), Upvc Extruded Glazing Beads Of Appropriate Dimension, Epdm Gasket, Zinc Alloy (White Powder Coated) 3D Hinges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Multi Point Locking Having Transmission Gear, Cylinder With Keeps And One Side Key, G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws, Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Welded Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. (Single / Double Glass Panes And Silicon Sealent Shall Be Paid Separately). Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Mm & Sash 67 X 110 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Upto 2.00 Sqm). , Providing And Fixing Factory Made Upvc White Colour Fixed Glazed Windows/Ventilators Comprising Of Upvc Multi-Chambered Frame And Mullion (Where Ever Required) Extruded Profiles Duly Reinforced With 1.60 ± 0.2Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length (Shape & Size According To Upvc Profile), , Upvc Extruded Glazing Beads Of Appropriate Dimension, Epdm Gasket, G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Welded Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge.(Single / Double Glass Panes And Silicon Sealant Shall Be Paid Separately). Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Fixed Window / Ventilator Made Of (Small Series) Frame 47 X50 Mm & Mullion 47 X 68 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Upto 0.75 Sqm.) , Providing And Fixing Factory Made Upvc White Colour Sliding Glazed Window Upto 1.50 M In Height Dimension Comprising Of Upvc Multi-Chambered Frame With In-Built Roller Track And Sash Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length (Shape & Size According To Upvc Profile), Appropriate Dimension Of Upvc Extruded Glazing Beads And Upvc Extruded Interlocks, Epdm Gasket, Wool Pile, Zinc Alloy (White Powder Coated) Touch Locks With Hook, Zinc Alloy Body With Single Nylon Rollers (Weight Bearing Capacity To Be 40 Kg), G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. (Single /Double Glass Panes,Wire Mesh And Silicon Sealent Shall Be Paid Separately). Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Note: For Upvc Frame And Sash Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Two Track Two Panels Sliding Window Made Of (Small Series)Frame 52 X 44 Mm &Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 1.75 Sqm) , Two Track Two Panels Sliding Window Made Of (Big Series) Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension . (Area Of Window Above 1.75 Sqm Upto 2.50 Sqm). , Three Track Three Panels Sliding Window With Fly Proof S.S Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of (Big Series) Frame 116 X 45 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.75 Sqm). , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Filling The Gap In Between Aluminium Frame & Adjacent Rcc/ Brick/Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete. Upto 5Mm Depth And 5 Mm Width , Providing And Fixing Fly Proof Stainless Steel Grade 304 Wire Gauge, To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.50 Mm All Complete. With 2Nd Class Teak Wood Beading 62X19 Mm Sqm 1404.25 With 12 Mm Mild Steel U Beading , Providing And Fixing 19Mm Thick Both Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approved Brand Boxes,Shelves,Racks,Almirah,Cupboard And Drawer Etc. Including Necessary Nails,Screws Etc. Complete As Per Direction Of Engineer-Incharge. , Providing And Fixing Cupboard Shutter With 19Mm Thick One Side Decorative And Other Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approved Brand Including 2Mm Thick Pvc Edge Banding Tape With Hot Glue By Edge Bending Machine Etc. With Auto Closing Spring Loaded Hinges (Hydraulic Type) Etc. Complete As Per Direction Of Engineer-In-Charge.(Payment Of Providing And Fixing Auto Closing Hinges Shall Be Paid Separately) , Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors,Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes , Providing And Fixing Stainless Steel Soft Closing Spring Hinges At 0 Degree Hinges (Hydraulic Type) Of Approved Make/Brand To Cupboard Shutters With Full Threaded Steel Screws Including Making Necessary Recess In Board And Finished Etc. Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Soft Closing Heavy Type Telescopic Drawer Channels Of Approved Make 500 Mm Long With Screws Etc.Complete As Per Directions Of Engineer- In-Charge. , Providing And Fixing 2Mm Thick 16 To 19Mm Wide Pvc Edge Binding Tape Of Approved Quality For Cupboard/Wardrobe Shutters Including Necessary Synthetic Resin Hot Pressed To Edges On Binding Machine Etc. Complete As Per Directions Of Engineer- In-Charge. , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate , Providing And Laying Vitrified Tiles In Floor In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement:4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily. Glazed Vitrified Floor Tiles Polished Finish Of Size Size Of Tile 600 X 1200 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Laying Polished Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Colour Of Black, Cherry/Ruby Red Or Equivalent , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge : Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing Of Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Stone Slab Of Colour Black, Cherry/Ruby Red Area Of Slab Over 0.50 Sqm , Extra For Providing Opening Of Required Size & Shape For Wash Basin/Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/ Granite/ Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre,Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills,Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : 12.5 Mm Thick Tapered Edge Glass Reinforced Gypsum (Grg) Board Conforming To Is: 2095- (Part 3):1996 (Boards With Bis Certification Marks) , Providing And Fixing At All Height False Ceiling Of 4Mm Thick Phenol Bonded Bamboo Mat Board (595X595mm) Conforming To Is:13958-1994 Including Providing And Fixing Of Frame Work Made Of Gi Angle 25X25x0.4 Mm Thick All Around Suitably Fixed To Wall With The Help Of Dash Fastener And Hanger Frame (600X600 C/C) Made Gi Slotted Tee Having Powder Coating On Bottom Side (30X25x0.3 Mm Thick For Main Member & 25X25x0.3 Mm For Cross Member) Connected To Ceiling With 2.64Mm Gi Wire And Anchor Fastener At Every Junction And Also Including Cost Of Making Openings For Light Fittings, Grills, Diffusers,Cut Outs Made With Frame Of Perimeter Channels Suitably Fixed All Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing 15 Cm Wide, 45 Cm Overall Semi-Circular Plain G.S. Sheet Gutter With Iron Brackets 40X3mm Size, Bolts, Nuts And Washers Etc., Including Making Necessary Connections With Rain Water Pipes Complete. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² , Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces),Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004,Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Providing And Fixing Approved Brand And Manufacture Ss Handle Of Size 600 Mm Fixed With Ss Screws Etc, Complete In All Respects As Per Manufacturers Specifications & As Directed By Engineer-In-Charge. , Providing And Fixing Approved Brand And Manufacture Ss 304 Grade Top & Bottom Patch Fixed With Ss Screws Etc. Complete In All Respects As Per Manufacturers Specifications & As Directed By Engineer-In-Charge. , Providing And Fixing Approved Brand And Manufacture Ss 304 Grade 900Mm Pull Handle With 32Mm Dia Fixed With Ss Screws Etc. Complete In All Respects As Per Manufacturers Specifications & As Directed By Engineer-In-Charge. , Providing And Fixing Approved Brand And Manufacture Ss 304 Grade Glass To Glass Lock Round Type With Ss Screws Etc. Complete In All Respects As Per Manufacturers Specifications & As Directed By Engineer-In-Charge. , Providing And Fixing Approved Brand And Manufacture Ss 304 Grade Floor Spring (Weight Approx 100-120Kgs) Fixed With Ss Screws Etc. Complete In All Respects As Per Manufacturers Specifications & As Directed By Engineer-In-Charge. , Supplying, Fitting And Fixing Full Height Wooden Partition Made Of Secondary Seasoned Hard Wood As Approved, Out Of 60Mm X 50Mm Section Both Horizontal And Vertical @ 600 C/C Including Covering The Above Frame (Primary Surface) With 12Mm Bwr Ply Wood On Both Side With 1.0 Mm Thk Laminate Finish And Necessary Edge Finish As Approved All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. , Providing And Fixing 40Mm Thick Cladding Comprising Of Wooden Framework Using 25Mx50mm Sections At A Maximum Spacing Of 600Mm In Any One Direction (Including Adding Members As Required) Covered With12mm Thick Bwp Ply Layered With 4Mm Thk. Veneer (Basic Rate Rs.60/-Sqftjon One Side Pasted And Pressed With Adhesive To Give A Uniform And Smooth Finish, Including 4Mm Thk. S.S. Strip Framework On All Sides Of Veneer Panels With Wooden Member Surround, Top Moldings/Margins, Etc. To Finish The Thickness, As Shown Complete In Drawing. All Members/Ply Etc. Shall Be Treated With Anti-Termite Solution As Per Norms. No Extra Shall Be Pald For Maling Of Openings, Door / Window Frames And For Making Provisions For Electric Condults. , Providing And Fixdng 18Mm Thick Granite Stone Work For Wall Lining Upto 10 M Height In Cement Mortar 1:3 (1Cement: 3 Coarse Sand) Including Pointing With White Cement Mortor With An Admixture Of Pigment To Match The Granite Shade Complete As Per Direction Of Engineer-In-Charge. , Providing And Laying Laminate Wooden Flooring (Grade Ac4, 8 Mm Thick Ambience Premium-Ac4), Having A Good Backing Layer Made Up Of Plastic Laminate Or Melamine As Specified By The Manufacturer And Approved By Engineer-Incharge. , Providing And Fixing Bamboo Composite Roof All Complete As Per Direction Of Engineer-In-Charge. , 1650 Mm Height Bamboo Boundary Wall As Per Direction Of Engineer-In Charge. , Providing Fitting And Fixing Of Branded Modular Lit And Wall Cabinet For Iitchen Along With Hardware Fittings At Senior Officers Colony As Per Direction Of Engineer-In-Charge. , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit With Modular Switch Modular Plate Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc.As Required. Group C , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 1.5 Sq.Mm. + 1 X 1.5 Sq.Mm. Earth Wire. , 2 X 2.5 Sq.Mm. + 1 X 2.5 Sq.Mm. Earth Wire. , 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , 4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5/6 Amps Switch , 15/16 Annual Periodical Maintenance Switch , 3 Pin 5/6 Annual Periodical Maintenance Socket Outlet , 6 Pin 15/16 Annual Periodical Maintenance Socket Outlet , Telephone Socket Outlet , Tv Antenna Socket Outlet , Bell Push , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module (100Mmx75mm) , 4 Module (125Mmx75mm) , 6 Module (200Mmx75mm) , 8 Module (125Mmx125mm) , 12 Module (200Mm X 150Mm) , Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required. 3 Module , 4 Module , 6 Module , 8 Module , 12 Module , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cm/M/W) Minimum 6.00, Air Delivery Minimum 210 Cum/Min , 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. , Supplying Including Fitting Fixing Of Following A.C. 2 Model Starter In The Existing 2 Model Modular Board Necessary Connection As Approved By The Deptt.)As 6 Required Complete And As Directed By The Department.25 Amps 2 Module Starter , Supplying Installation Testing And Commissioning Of Exhust Fan 225 Mm Air Flow As Required 1.5 Sq Mm Copper Multstrand Wire Connection An As Specified 3 And Directed By The Deptt. Orient/Usha/Cromton Make , Supplying And Fixing Of Recessed Jaquar Or Equivalent Philips/ Wipro Led Spot Light Fittings Complete With Shade, Back Plate Including Connection Cable, As 5 Approved By The Deptt.S Etc. As Required. 7W Led Cob , Supplying, Installation, Testing And Commission Of The Following Indoor Decorative Recess Mounted Led Down Lighter Luminaries Of Model No- Dn296b Led15s-6500Psu Wh Hsn Code 9405 Complete With All Accessories Such As Ballast, Starter Etc. In The False Ceiling Type Armstrong /Gypsum Or Similar Celling 6 Mounting With Necessary Support With 1.5 Sq.Mm. P.V.C. Insulated S.C.Copper Conductor As Required And As Directed By The Department (Philips/Jaquar / Lt/Wipro Make) , Supplying, Installation, Testing And Commission Of The Following Indoor Decorative Recess Mounted Liner Led Strip Light Premium 50W With Derver Complete With All Accessories Such As Ballast, Starter Etc. In The False Ceiling Type Armstrong/Gypsum Or Similar Celling Mounting With Necessary Support With 1.5 Sq.Mm. P.V.C. Insulated S.C.Copper Conductor As Required And As Directed By The Department (Philips/Jaquar/Lt/Wipro Make). 50 W Led Strip Light
Contract Date: May 30, 2026 Contract Value : 53.05 Lakh
Government Departments No of Bidders 2
42.
Heavy Industries and Public Enterprises #9940997 Technical Bid
Tender For U200 New Control Room Revamping-Brick work demolishing 2 Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In lime mortar with old mughal bricks 3 RCC demolition 4 Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as perdirection of Engineer -in-Charge. 5 Pcc demolishing 6 Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:4:8 or leaner mix ( including equivalent design mix) 7 Demolishing wooden door 8 Dismantling doors, windows and clerestory windows (steel or wood ) shutterincluding chowkhats, architrave, holdfasts etc. complete and stacking within 50metres lead:Of area beyond 3 sq. metres 9 Dewatering with pump 10 Bailing out water/slush using pump above 5HP and up to 10 HP, includingconveyance to site and erection, cost of fuel, lubrication oil and other stores, pay ofstaff etc complete. All deposits/slush shall be shifted to designated location with in1km lead 11 Demolishing old iron ventilators 12 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. orR.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.Bwork) as per direction of Engineer-in-charge. 13 Demolishing existing wooden partition 14 Dismantling wooden boardings in lining of walls and partitions, excluding supportingmembers but including stacking with in 50 metres lead:Upto 10 mm thick 15 Demolishing false ceiling 16 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking thematerial within 50 metres lead of :Asbestos cement Sheet 17 Excavation work 18 Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil 19 soling 20 Soling with rough stone of size 200 mm, well packed and filling voids with stonechips and required profile with hammer dressed stones having no side less than 15cm, with minimum depth of 20 cm includingpreparing the bedding surface etc. all complete 21 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) 22 RCC upto plinth level 23 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) 24 Steel reinforcement work upto plinth level 25 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelMild steel and Medium Tensilesteel bars 26 Solid block masonry upto plinth level 27 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for foundation andplinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etccomplete 28 Bituminous painting 29 Painting with black anti- corrosive bitumastic paint of approved brand andmanufacture to give an even shade:Two or more coats on new work 30 Red earth filling 31 Filling with contractors own earth ( excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge 32 RCC for column above plinth level 33 Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources) 34 Solid block masonry 35 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in :CM 1:6 ( 1 cement : 6 coarse sand) etc 36 RCC beam 37 Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 38 Steel reinforcement above plinth level 39 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Cold twisted bars 40 Plastering with 12mm cement plaster mix 1:4 41 Plastering with 12 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand ) 42 Ceiling 43 Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size andother end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mmrunning at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular toG.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mmlong G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommended jointing compound, jointing tapes, finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturers specification and alsoincluding the cost of making openings for light fittings, grills, diffusers, cutouts madewith frame of perimeter channels suitably fixed, all complete as per drawings,specification and direction of the Engineer in Charge but excluding the cost ofpainting with:12.5 mm thick tapered edge gypsum moisture resistant board 44 Shuttering for footing 45 Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete 46 Shuttering for column above plinth level 47 Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts 48 Shuttering for beams 49 Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers 50 Shuttering for slab 51 Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform 52 Shuttering for sunshade 53 Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges 54 Shuttering for stair 55 Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases) 56 Applying SBR latex mixed plaster and applying bonding agent 57 Providing, mixing and applying SBR polymer (of approved make such as NitobondSBR/SBR Reomix/Cera SBR Latex of M/s Fosroc/BASF/Cera Chem or Similiarrespectively) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer as per manufactures specification) including surface cleaning and application of bonding slurry to the prepared surface for proper adhesion as per manufacturers specificationas and directions of Engineer in chargeNote:Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made onlyafter proper wet curing has been done and surface has been satisfactorily evaluated by sounding /tapping with a blunt metal instrument of 12 mm average thickness includingscaffoldings upto 4 m height 58 Thixotropic Non shrink mortar 59 Providing and applying single component fibre reinforced thixotropic non shrinkrepair mortar such as BASF EMACO S48CT or FOSROC/BOSTIK product forcolumns, beams, slabs and otherstructural members with 4 ltrs of potable water per 25kg of product, mixing by heavyduty,slow speed drill with spiral mixing paddle or a Pan type mixers etc. afterpouring the water in a mixing vessel, mixed materialshall be applied both by trowel or spray application and finished to get a uniformthickness and finish and all works as per manufactures specifications and as directedby the Engineer in charge, including curing, cost of materials, labour, scaffoldingupto a height of 4 mtr, conveyance etcThe work shall be carried by an agency havingsufficient experience and should ensure a guarantee of 5years. Only skilled andexperienced persons shall be employed for this purpose. 60 Supply and laying first quality vitrified tiles of size 1200*600 61 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including spacers 3mm and grouting the joints with epoxy which shall be paid extra., complete.Size of Tile 1200x600 mm 62 Epoxy grouting 63 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm or nearest 64 providing & fixing anti skid floor tile at toilet 65 Providing and fixing premium quality ceramic digital anti-skid floor tiles ofmake
Kajaria/Nitco/Simpolo/Cera or approved brand conforming to IS :15622 (thickness to be
specified by the manufacturer), in all colours, shadesof size matching to wall tiles or as approved by
Engineer -in-Charge, over12 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) with tilespacers 3mm and jointing with epoxy joint fillers with pigment of matchingshade of approved brand in approved pattern
with two or more desgin tilescomplete. 66 Providing & fixing premium quality ceramic digital wall tile 67 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and including spacers 3mm and grouting the joints with epoxy which shall be paid extra., complete 68 painting 69 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additivesof required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over andincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 70 Window grill 71 Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 72 Aluminium Frame work for Doors windows and partitions 73 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) 74 Shutter for doors and windows 75 For shutters of doors, windows & ventilators including providing and fixinghinges / pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paidfor separately)Powder coated aluminium (minimum thickness of powder coating 50micron) 76 UV sheet for doors 77 Providing and fixing 4 mm thick UV sheet in panelling fixed in aluminum doors,windows shutters and partition frames with C.P. brass / stainless steel screws , UVSheet finished in two diffrent colours and complete as per architectural drawings anddirections of Engineer - in-Charge 78 Glass 79 Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) 80 Lock for doors 81 Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete 82 Hinges 83 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:100 mm 84 Handles 85 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:100 mm 86 Tower bolts 87 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barreltype) with necessary screws etc. complete : (Copper oxidized as per IS : 1378)250x10mm 88 FRP door frame 89 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. 90 FRP door shutter 91 Providing and fixing to existing door frames.30 mm thick Fiberglass ReinforcedPlastic (F.R.P) flush door shutter in different plain and wood finish made with fireretardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate allaround, with suitable wooden blocks inside at required places for fixing of fittingsand polyurethane foam (PUF) / Polystyrene foam to be used all filler materialthroughout the hollow panel, casted monoolithically with testing parameters of F.R.P.laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineerin-charge. 92 25 mm PVC concealed 93 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe10kgf /cm2 94 32mm PVC concealed 95 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2 96 50mm PVC concealed 97 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe6 kgf/cm2 98 63mm PVC concealed 99 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed workincluding cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 100 32 mm pvc pipe exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mmdia 6 Kgf/cm2 - External work - Exposed on wall 102 50mm pvc pipe exposed on wall 103 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall 104 110mm pvc pipe trenching and refilling 105 Providing and fixing PVC pipes includes joints of pipes with one step PVC solventcement, trenching, refilling & testing of joints complete as per direction ofEngineer in CHarge. 110 mm dia 4 Kg/cm2 106 63mm dia elbow 107 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63 dia 45 degree Elbow 108 63mm 45 degree elbow 109 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63 dia 45 degree Elbow 110 63 dia pvc door elbow 111 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Door Elbow 112 63 dia tee 113 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipesincluding jointing with PVC solvent cement - 63x63x63 mm dia Tee 114 63mm dia pvc bend 115 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Bend 116 63mm dia door tee 117 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63x63x63 mm dia Door Tee 118 63mm dia vent cowl 119 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia vent cowl 120 110-63mm pvc reducer 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110x63 mm dia Reducer 122 63x50mm pvc reducer 123 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63x50 mm dia Reducer 124 63mm dia socket/coupling 125 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia End cap 126 63mm dia coupling 127 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia End cap 128 110mm dia elbow 129 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow 130 110mm dia 45 degree elbow 131 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 132 110 mm dia door elbow 133 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement-110 mm dia Door Elbow 134 110mm dia bend 135 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend 136 110mm dia tee 137 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee 138 110mm dia door tee 139 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 140 110mm dia socket/coupling 141 Providing and fixing PVC moulded fittings/accessories for Rigid PVCpipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 142 GM ball valve 143 Providing and fixing GM ball valve of approved quality (screwed end) :
25mm nominal bore 144 Providing and fixing CP brass bib cock long body 145 Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore 146 Providing and fixing CP brass stop cock 147 Providing and fixing C.P brass stop cock ( concealed) of standard design and ofapproved make conforming to IS: 893115 mm nominal bore 148 CP brass angle valve 149 Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore 150 PVC ball valves 151 Providing and fixing PVC ball valve (ISI marked) of approved brand for Rigid PVCpipes, including jointing with PVC solvent cement:
25mm nominal bore. 152 CP brass shower rose 153 Providing and fixing C.P. brass shower rose with arm of 15 or 20 mminlet:
100 mm diameter 154 SS soap Dish 155 Supplying and fixing Stainless steel soap dish including cost of materials and labourcharges etc complete as per the direction of site Engineer-in-charge. 156 Towel rod 157 Supplying and fixing CP Towel rod 45cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-incharge. 158 Health faucet 159 Supplying and fixing CP Health faucet good quality including cost of materials andlabour charges etc. complete as per the direction of site engineer-in-charge 160 CP gratings 161 Providing and fixing CP grating of approved quality.
Rectangular type withopenable circular lid
150 mm nominal size square 100 mm diameter of theinner hinged round grating 162 Floor trap 163 Providing and fixing PVC moulded Floor trap for sanitary pipelines, including jointing PVC pipes with PVC solvent cement and filling gaps with cement groutFloor trap 4 way/3 way 164 Labour charge 165 Miscellaneous labour 166 ISMB 200 167 Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved epoxy primer and 2 or more coats of epoxy paint, including welding andbolted with special shaped washers etc. complete 168 Steel reinforcement paint 169 Providing and applying anti corrosive Nitozinc primer/Cera cte SP CI/ protectosilCIT, two or more coats, over the steel reinforcement as per the manufacturesspecification including scaffolding upto height 4 mtr and as directed by Engineer-incharge. The product shall be applied on the reinforcement surface after throughlycleaning. painted area of steel shall be considered for payment 170 Orissa pattern W.C. pan 171 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mmSand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, includingflush pipe, manually controlled device (handle lever) conforming to IS : 7231, withall fittings and fixtures complete, including cutting and making good the walls andfloors wherever require:White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests 172 Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked black solid plastic seat andlid 173 providing & fixing mirror 174 Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Rectangular shape 453x357 mm 175 providing & fixing wash basin 176 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 177 Tap pvc PTMT 178 Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominalbore, 86 mm long, weighing not less than 88 gms 179 Providing new septic tank 180 Supplying and installing ready made RCC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge incl supply of CC/Sand/06mm aggregate for the preparation of bed) 35 to 50 flush capacity 181 SUPPLY PARTDISTRIBUTION BOARDS 182 Supply of 63A, 3 phase 415V 4 way Verical Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 63A, 4 pole MCCB as incomer and 1 No.s of 40A 4 pole MCCBs and 2 No. of 32A 4 pole MCCB as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB: Standard/Havells/ABB/Siemens/Hager/Schneider 183 Supply of 40A, 3 phase 415V 4 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 40A, 3 phase 4P MCB & 40A, 30mA 3 phase RCCB as incomer and 9 No.s of 20A SP MCBs as outgoingMake of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider 184 Supply of 25A, 3 phase 415V 6 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 25A, 3 phase 4P MCB & 25A, 30mA 3 phase RCCB as incomer and 12 No.s of 6A SP MCBs as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider 185 LIGHTING AND WIRING.LIGHT FIXTURES AND FANS, SWITCHES AND SOCKETS 186 Supply of LED downlight round (Approximate cutout dia 15cm), 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above 187 Supply of LED downlight round (Approximate cutout dia 20cm), 20W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 2000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above 188 Supply of LED wall light, 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above 189 Supply of LED mirror light, 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above 190 Supply of LED tube light batten, 4 feet, 20W (Approximate), 230V, 50Hz AC supply, Lumen efficacy: 100 Lumens/W or above, Lumens: 2000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above 191 Supply of Exhaust Fan, 225 mm sweep Make:USHA/CROMPTON/BAJAJ/ORIENT/KHAITHAN/HAVELLS 192 Supply of CEILING FANMOTOR TYPE: BLDC230 V, 50 HZ, AC, 1200 MM SWEEP WITH REMOTE CONTROL AND ALL ACCESSORIESSTAR RATING: 5MAKE: ATOMBERG/CROMPTON/HAVELLS/ORIENT/LUCAS/HALONIX. 193 Supply of Electric calling bell, 230V, 50HzMake:Anchor/havells/L&T/Legrand 194 Supply of Bell switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 195 Supply of 6A switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 196 Supply of 25A switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 197 Supply of 6A Socket, for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 198 Supply of 25A Socket, for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 199 Supply of RJ11 Socket, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 200 Supply of RJ45 Socket, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 201 Supply of Concealed box, Plate and frame for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 202 Supply of Concealed box, Plate and frame for 3 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 203 Supply of Concealed box, Plate and frame for 4 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 204 Supply of Concealed box, Plate and frame for 6 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 205 Supply of Concealed box, Plate and frame for 12 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell 206 Modular type wiring 207 Supply of materials required for copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 208 Supply of materials required for copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 209 Supply of materials required for copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 210 Supply of materials required for circuit wiring for RJ11 in PVC medium gauge conduit with modular type switch - using telephone cable (twin flat copper PVC insulated, 2 x 0.5 sq mm, ISI marked, Make: Finolex, Anchor, V-guard, Traco, Sark, Orbit, Polycab) in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Sockets) 211 Supply of materials required for circuit wiring for RJ45 sockets in PVC medium gauge conduit with modular type switch - using CAT 6 UTP cable (Make: D-link, Finolex, Polycab, Lapp) in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Sockets) 212 Supply of materials required for wiring for Smoke Detectors in recessed PVC medium gauge conduit - using 3 x 1 sq. mm. PVC insulated copper cable in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Smoke detector)(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 213 Supply of materials required for copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in srecessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets). (For exceeding 5 meter point wiring. Tthis will be in addition to point wiring rate above).(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 214 Supply of materials required for copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring. This will be in addition to point wiring rate above).(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 215 Supply of materials required for copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring, this will be in addition to point wiring rate above).(Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.) 216 Supply of materials required for Copper circuit wiring in PVC conduit - Circuit Wiring with 1.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 1.5 sq. mm. PVC insulated copper wire for loop earthing as required. 217 Supply of materials required for Copper circuit wiring in PVC conduit - Circuit Wiring with 2.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 2.5 sq. mm. PVC insulated copper wire for loop earthing as required. 218 Supply of 10 pair telephone junction box and accessories for surface mounting, Make: Syntex, Krone 219 INSTALLATION PARTModular type wiring and Installation 220 Installation, testing and commissioning of LED downlight of all types complete with all accessories etc. in false ceiling including connection with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required. 221 Installation of ceiling fans, making connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required 222 Installation of exhaust fan upto 300 mm sweep in the existing opening including making the holes to suit the size of the above fan making good the damage, connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor three core cable etc. as required 223 Installation, testing and commissioning of LED tube lights, wall lights and mirror lights of all types complete with all accessories etc. including connection with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required. 224 Installation of calling bell at DCW room, making connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required 225 Installation, testing and commissioning of Smoke Detectors complete with all accessories etc. including connection with 1.5 sq.mm PVC insulated copper conductor three core cable etc. as required. 226 Fixing of 6/25 amps modular type sockets, switches, bell switches, RJ11 and RJ45 modular sockets (other than included in point wiring) with front plate in surface or in recess including providing and fixing suitable size metal box, inter connections etc as required. 227 Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for light point/fan point/exhaust fan point using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. 228 Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for socket point using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 4 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. 229 Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for calling bell point using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. 230 Copper point wiring in PVC medium gauge conduit for Smoke Detector - Wiring for smoke detector point using 1/1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1/1.5 sq. mm. PVC insulated copper 3 core cable as required 231 Copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in srecessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets). (For exceeding 5 meter point wiring. Tthis will be in addition to point wiring rate above). 232 Copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring. This will be in addition to point wiring rate above). 233 Copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring, this will be in addition to point wiring rate above). 234 Copper circuit wiring in PVC conduit - Circuit Wiring with 1.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 1.5 sq. mm. PVC insulated copper wire for loop earthing as required. 235 Copper circuit wiring in PVC conduit - Circuit Wiring with 2.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 2.5 sq. mm. PVC insulated copper wire for loop earthing as required. 236 LAN circuit wiring in PVC conduit - Circuit Wiring with UTP/Ethernet cable in recessed PVC conduit as required. 237 Telephone circuit wiring in PVC conduit - Circuit Wiring with two core telephone cable in recessed PVC conduit as required. 238 DB installation and Cabling 239 Installation, testing and commissioning of 63A, 3 phase 415V 4 way Verical Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 63A, 4 pole MCCB as incomer and 1 No.s of 40A 4 pole MCCBs and 2 No. of 32A 4 pole MCCB as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB: Standard/Havells/ABB/Siemens/Hager/Schneider 240 Installation, testing and commissioning of 40A, 3 phase 415V 4 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 40A, 3 phase 4P MCB & 40A, 30mA 3 phase RCCB as incomer and 9 No.s of 20A SP MCBs as outgoingMake of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider 241 Installation, testing and commissioning of 25A, 3 phase 415V 6 way Horizontal Distribution boardIn sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as requiredFor surface mountingWith 25A, 3 phase 4P MCB & 25A, 30mA 3 phase RCCB as incomer and 12 No.s of 6A SP MCBs as outgoing (Including required dummy to close the vaccant spaces)Make of DB: Standard/Havells/ABB/Siemens/Hager/SchneiderMake od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider 242 Laying, dressing and clamping of following cables through exsisting trays / structures / racks / columns / walls etc to the new DB .Cable shall be supplied by KMML. All other materials required for clamping are under the scope of contractor. 243 (3.5 x 25 to 3.5 x 50) sq. mm AYFY/XLPE cable 244 Glanding and termination at DBs side of PVC cable using DC glands/ lugs including supply of cable glands, lugs, aluminium crimping sockets, nuts bolts etc. required for this work. Gland earthing as per standards shall be done by the contractor. 245 (3.5 x 25 to 3.5 x 50) sq. mm AYFY/XLPE cable 246 Telephone switch relocation 247 Installation, testing and commissioning of 10 pair telephone junction box and accessories for surface mounting, Make: Syntex, Krone 248 Approval from Electrical Inspectorate. 249 Preparation of all electrical drawings and obtainig statutory approval from electrical inspectorate for the new DBs Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Apr 06, 2026 Contract Value : 77,701
Government Departments No of Bidders 1
44.
Housing Urban and Rular Development #9924645 Technical Bid
Tender For P/F Overhead Cantilever/Gantry Direction Board In Sector-74,75,76 And 77 X-Ing, Noida. - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil. The contractor has to detect different utilities like sewer line water supply line electric cable telephone cable gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of Engineer-in-charge.All kinds of soil. 2 Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 m and lift upto 1.5 m 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) 4 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete 5 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as perdirection of the Engineer - in - charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).All works upto plinth level 6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars 7 Steel work welded in built up sections/ framed work, including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 8 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 9 Retro-Reflective sheeting type-XI with 4mm thick ACM single SideProviding & Fixing of reflective signs with a corrosion resistant 4mm thick with 0.4 to 0.5 mm both side aluminium skin aluminium composite panel face to be fully covered with High intensity prismatic sheeting type XI as per IRC-67:2012 retro reflective sheeting with back frame MS angle of 35x35x5mm Legenda, letters, numerals and borders etc should be as per MoRTH specification No-801.3.7. The Sheeting shall have a pressure- Sensitive adhesive of the aggressive lack type requiring no heat. solvent other preparation for adhesion to a smooth clean surface, in a manner recommended by the sheeting manufacture. The ACM (Aluminium Composite Materials) Shall be fixed on the Back frame MS Angle with riveting. Micro Prismatic type IV Retro reflective sheeting confirming to ASTM D4956-09 Shall be pressure fixed. The Retro reflective, daytime colour and luminance, shrinkage, flexiblitily, liner removal, adhesion, impact resistance, specular glass and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obrained from international/Government Laboratory/institute by the manufacture of the sheeting and in case the certificate is obtained from internation condition, it should also be obtrained from indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively a certificate conforming to ASTM Specification (D4956-09) on artifical accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally, in such a situation, the Employer/Client. if so desires, could seek for a performance guarantee, in such a situation, the Employer/Client. if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & Proof of the same Report shall be uploaded which quoting tender. The rate shall include all materials, labour, T&P, Transportation, installation and incidentals all complete as per direction of the Engineer-in-chage. 10 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 11 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 12 Mobile Hydraulic Crane 35 tonne capacity (173HP) 13 Demolishing R.C.C. work manually / by mechanicalmeans including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-In-Charge 14 Retro-Reflective Signs (stainless steel Frame and Post with one side sings)Supply & Fixing of reflective signs board (single side) of size 1.50 x 1.20m retro reflective sheeting of HIP grade type-IV, the board shall be fixed on 50mm SS 304 grade ofwith a corrosion resistant 4mm thick ACM sheet of standard make as per MORTH specification. The Board shall be fixed using 2 man post 45x45x60 cm cement concrete foundation. The stainless steel joint welding of SS pipe work shall be band and grinder property inclluding bufting so and to give uniform shinging at welded of SS pipe work shall be band and grinder property. The Retro reflective sheeting shall be tested for a certificate of having the sheeting at welded joints. The Retro reflective, daytime colour and luminance, shrinkage, flexiblitily, liner removal, adhesion, impact resistance, specular glass and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obrained from international/Government Laboratory/institute by the manufacture of the sheeting and in case the certificate is obtained from internation condition, it should also be obtrained from indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively a certificate conforming to ASTM Specification (D4956-09) on artifical accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally, in such a situation, the Employer/Client. if so desires, could seek for a performance guarantee, in such a situation, the Employer/Client. if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 Legends, letters, Numerals and borders etc. should be as per MoRTH spectification No. 801.3.7 Proof of the same in form of goverment report shall be uploaded white quoting tender.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Uttar Pradesh View Result →
45.
Defence #9877085 AOC
Tender For Green Table Cloth 10X2 Mtr , Foot Mat 3X2 , Office Chair , Computer Chair , Dari 15X 15 Ft , Steel Tiffin Box 5 Container , Door Curtain 7X4 , Window Curtain 5X6 , Executive Revolving Chair High Back , Adjustable Writing Table Top , White Board Both Side 4X3 With Sand , Computer Table , Towel For Toilet , Grass Cutter Trimmer Wire 3Mm , Cable Wire 8Mm 2 Core , Trimmer Wire , Electric Safety Hand Gloves , Rubber Stamp , Floor Mat 6X4 , Barrier 6X6 , Cone Barrier As Per Sample , Transparent Packing Paper , Uniball Air 5 X Blue And 03 X Black , White Envelope Tajmahal 4X6 , Electric Cable 2 Core 5 Sqmm , Telephone Set Beetel M78 Plan Set , Telephone Set Beetel M71 , Telephone Cable Single Pair , Memorabilia Of Unit Citation Photo Frame Bronze Covered , Cctv Led Monitor Size 32 Inch , Prescription Book Pad Containing 100 Pages , Artificer Repair Book Armr Shop Register , Work Order Book Containing 100 Pages , Job Card Containing 100 Pages , Sanitary Diary Register 400 Pages , Key In Out Record Register , Morning Parade State Army Civil Staff Register , Soldier Dossier Cover As Per Sample , Black Laser Toner Cartridge Cc388A , Permanent Marker , File Cover As Per Sample , A4 Paper Ream , Legal Ream , Fevical 500 Ml , Re Writable Cd Dvd , File Tag , Long Roll Permanent Staff , Sick Report Jcos Or Recruits , 8Pt4 Volt Bty Charger Bms , Cash Book 70 Pages , Do Pad A4 Size , Digital Glass Photo Frame , Arms Issue Register 500 Pages , Ribbon Golden Half Inch , Ribbon Golden 1 Inch , Fevibond 90 Ml , Lecture Stand As Per Sample , Engagement Pad As Per Sample , Fly Catcher , Visitor Chairs , Electric Bush Cutter 2200 Rpm , Water Camper 20 Ltr , Borosil Glass , Tea Container Milton 10 Ltr , Water Bottle 20 Ltr , Red Cushion Chair , Wall Fan , Suit Case For Dak , Acrylic Writing Desk Table 24X18 Inches , Steel Rack For Ration Size 8X2X2 , Vegetable Fruit Crate Size 2X1Pt5X1Pt5
Contract Date: Ref. Documents Contract Value : 11.24 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttarakhand View Result →
46.
Housing Urban and Rular Development #9786076 Price Bid
Tender For Mow/Deposit Work Under Jail-3 Sub Dn, Pwd Bhopal-1 1.2 Transportation by manual labour including loading, unloading and stacking for lead up to 50 metre. 1.2.1 Lime, moorum, building rubbish 1.2.2 Earth 1.2.3 Manure or sludge 1.2.4 Excavated rock 1.2.5 Sand, stone aggregate below 40mm nominal size 1.2.6 Stone aggregate 40mm nominal size and above 1.2.7 Stone soling 1.2.8 Bricks 1.2.9 S.W. Pipes 1.2.9.1 100 mm dia 1.2.9.2 150 mm dia 1.2.9.3 200 mm dia 1.2.9.4 250 mm dia 1.2.9.5 300 mm dia 1.2.9.6 350 mm dia 1.2.9.7 400 mm dia 1.2.9.8 450 mm dia 1.2.9.9 500 mm dia 1.2.9.10 600 mm dia 1.2.10 R.C.C. pipes, Steel cylinder, R.C. pipes, C.I. pipes, and reinforced cement pipes 1.2.10.1 100 mm dia 1.2.10.2 125 mm dia 1.2.10.3 150 mm dia 1.2.10.4 200 mm dia 1.2.10.5 250 mm dia 1.2.10.6 300 mm dia 1.2.10.7 350 mm dia 1.2.10.8 400 mm dia 1.2.10.9 450 and 500 mm dia 1.2.10.10 600, 700, 750 and 800 mm dia 2 1.3 Add extra for every additional lead of 50 metre or part thereof. 1.3.1 Lime, moorum, building rubbish 1.3.2 Earth 1.3.3 Manure or sludge 1.3.4 Excavated rock 1.3.5 Sand, stone aggregate below 40mm nominal size 1.3.6 Stone aggregate 40mm nominal size and above 1.3.7 Stone soling 1.3.8 Bricks 1.3.9 S.W. Pipes 1.3.9.1 100 mm dia 1.3.9.2 150 mm dia 1.3.9.3 200 mm dia 1.3.9.4 250 mm dia 1.3.9.5 300 mm dia 1.3.9.6 350 mm dia 1.3.9.7 400 mm dia 1.3.9.8 450 mm dia 1.3.9.9 500 mm dia 1.3.9.10 600 mm dia 1.3.10 R.C.C. pipes, Steel cylinder, R.C. pipes, C.I. pipes, and unreinforced cement pipes 1.3.10.1 100 mm dia 1.3.10.2 125 mm dia 1.3.10.3 150 mm dia 1.3.10.4 200 mm dia 1.3.10.5 250 mm dia 1.3.10.6 300 mm dia 1.3.10.7 350 mm dia 1.3.10.8 400 mm dia 1.3.10.9 450 and 500 mm dia 1.3.10.10 600, 700, 750 and 800 mm dia 3 2.1 Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. in all kinds of soil. 2 2.2 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 5 2.3 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 6 2.4 Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material. 2.4.1 beyond 30 cm girth up to and including 60 cm girth 2.4.2 beyond 60 cm girth up to and including 120 cm girth 2.4.3 beyond 120 cm girth up to and including 240 cm girth 2.4.4 above 240 cm girth 7 2.5 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m lead and lift up to 1.5 m, disposed soil to be levelled and neatly dressed, All kinds of soil 8 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil 9 2.7 Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. 2.7.1 Ordinary rock 2.7.2 Hard rock (requiring blasting) 2.7.3 Hard rock (blasting prohibited) 10 2.8 Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (No extra lift is payable if work is done by mechanical means)Note:-Excavation of hard rock shall be the property of the contractor subject to recovery. excavated material has to shift from site within 15 days after instruction issued by Engineer-InCharge otherwise after this penalty will imposed on contractor at the rate of Rs 50 per cum per day 2.8.1 Ordinary rock 2.8.2 Hard rock (requiring blasting) 2.8.3 Hard rock (blasting prohibited) 11 2.9 Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (No extra lift is payable if work is done by mechanical means) in all kinds of soil 2.9.1 Pipes, cables etc., not exceeding 80 mm dia. 2.9.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.9.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm. 12 2.10 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). 13 2.11 Extra for excavating trenches for pipes, cables, etc., in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 14 2.12 Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, depth up to 1.5 m including including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : 2.12.1 Ordinary rock : 2.12.1.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.1.2 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 2.12.1.3 Pipes, cables exceeding 300 mm dia but not exceeding 600mm dia 2.12.2 Hard rock (requiring blasting) 2.12.2.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.2.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.12.2.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600mm dia 2.12.3 Hard rock (blasting prohibited) 2.12.3.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.3.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.12.3.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600mm dia. 15 2.13 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 16 2.14 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 3m in depth but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 17 2.15 Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). 2.15.1 Depth not exceeding 1.5 m. 2.15.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.15.3 Depth exceeding 3 m but not exceeding 4.5 m. 18 2.16 Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered). 2.16.1 Depth not exceeding 1.5 m. 2.16.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.16.3 Depth exceeding 3 m but not exceeding 4.5 m. 19 2.17 Close timbering over areas including strutting, shoring and packing, cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered) : 2.17.1 Depth not exceeding 1.5 m. 2.17.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.17.3 Depth exceeding 3 m but not exceeding 4.5 m. 20 2.18 Extra for planking, strutting and packing materials for cavities (in close timbering) if required to be leftpermanently in position. (Face area of timber permanently left to be measured). 21 2.23 Extra rates for quantities of works, executed: 2.23.1 In or under water and/or liquid mud, including pumping out water as required. 2.23.2 In or under foul position, including pumping out water as required. Note: - The extra percentage rate is applicable in respect of each item but limited to quantity executed in difficult conditions. The depth shall be reckoned correct to 0.1 metre. 0.05 metre or more shall be taken as 0.1 metre and less than 0.05 metre ignored. 22 2.24 Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 23 2.25 Extra for every additional lift of 1.5 m or part thereof in excavation. (No extra lift is payable if work is done by mechanical means) 2.25.1 All kinds of soil. 2.25.2 Ordinary or hard rock. 24 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm. 25 2.27 Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) 2.27.2 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. 26 2.28 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then refiling the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc., disposing of surplus excavated soil; as directed within a lead of 50 m and lift upto 1.5m. 2.28.1 All kinds of soil. 2.28.2 Ordinary rock 2.28.3 Hard rock (requiring blasting) 2.28.4 Hard rock (blasting prohibited) 27 2.29 Supplying chemical emulsion in sealed containers including delivery as specified. (Chlorpyriphos/ Lindane emulsifiable concentrate of 20%) 28 2.30 Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.30.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 liters / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall and rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.4 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling 10mm dia and 200mm deep holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. 29 2.31 Deduct for disposed soil not levelled and neatly dressed. 30 2.32 Preconstruction antitermite treatment to the building under construction by providing.Stage 1: Treatment should not be carried out when it is raining or when soil is wet with rain or subsoil water. This also applies to fill up soil within the plinth area before laying the subgrade for flooring. 31 2.33 Making bore holes for providing dowel bars at designed depth in rock foundation by drilling 40 mm dia bore hole in rock including necessary bending hooking, in position and grouting with cement slurry etc. complete as per drawing and specification. (Steel to be paid separately). 32 2.34 Excavation in soil using hydraulic excavator and including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- section, and transporting to the appropriate ground contour, location and levelling and dressing earth neatly with all lifts and lead upto 1000 metre. 33 2.35 Earth work in rough excavation by any means and bankingfilling excavated earth in layers not exceeding 20cm in depth, breaking clods, watering rolling each layer with 1/2 tonne in embankments for roads, flood banks, marginal bank and guide bank of filling up ground depression within campus, lead upto 50m and all lift. All kinds of soil. 34 2.36 Bankingfilling excavated earth in layers not exceeding 20cm in depth, breaking clods, watering rolling each layer with 1/2 tonne roller or wooden or steel rammers etc. and rolling every 3rd and top-must layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal bank and guide bank etc. lead upto 50m and lift upto 1.5m. All kinds of soil. 35 2.37 Deduct for not rolling with power roller of minimum 8 tonnes for bankingfilling excavated earth in layers not exceeding 20cm in depth. 36 2.38 Deduct for not watering with the excavated earth for bankingfilling 37 2.39 Providing and laying of permanent piping technology anti-termite treatment before flooring work by installing LLDP (Low linear density polyethylene) tube of 8 mm O.D. & 6.4 mm I.D.with inbuilt pressure compensation chip at every 30 cm interval in the tube,. The contractor shall submit approved line plan for piping system and junction boxes dully approved by Engineer-in- charge with bond of 5 year warranty. 2.39.1 Permanent piping system with Junction boxes 2.39.2 Anti-termite chemical injected area 38 2.40 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. (All kinds of soil) 39 3.1 Cement mortar 1:1 (1 cement: 1 sand) 40 3.2 Cement mortar 1:2 (1 cement: 2 sand). 41 3.3 Cement mortar 1:3 (1 cement: 3 sand). 42 3.4 Cement mortar 1:4 (1 cement: 4 sand). 43 3.5 Cement mortar 1:5 (1 cement: 5 sand). 44 3.6 Cement mortar 1:6 (1 cement: 6 sand). 45 3.7 Cement mortar 1:2 (1 cement: 2 stone dust). 46 3.8 Cement mortar 1:2 (1 cement: 2 marble dust). 47 3.9 White cement mortar 1:2 (1 white cement: 2 marble dust). 48 3.10 Cement mortar 1:5 (1 cement: 5 marble dust). 49 3.11 White cement mortar 1:3 (1 white cement: 3 marble dust). 50 3.12 White cement mortar 1:5 (1 white cement: 5 marble dust). 51 3.13 Mortar in lime , surkhi (50% red and 50% light yellow) and marble dust 1:1.5:0.5 52 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-25 – Grade concrete 4.1.1.2 M-20 – Grade concrete 4.1.1.3 M-15 – Grade concrete 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate 4.1.3 With fly ash. 4.1.3.1 1:2:3½:9 (1 ordinary Portland cement : 2 Fly ash : 3½ sand: 9 graded stone aggregate 40 mm nominal size) 4.1.3.2 1:2½:4:11 (1 ordinary Portland cement : 2½ fly ash : 4 sand : 11 graded stone aggregate 40 mm nominal size) Note: No fly ash is to be added to Portland Pozzolona cement in any case which itself contains fly ash. 53 4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1 With 20mm nominal size graded stone aggregate 4.2.1.1 M-25 – Grade concrete 4.2.1.2 M 20 – Grade concrete 4.2.1.3 M 15 – Grade concrete 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 4.2.2 With 40mm nominal size graded stone aggregate 4.2.2.1 M-15 - Grade concrete 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 54 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for : 4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. 4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. 4.3.3 Above plinth: Columns, pillars, posts and struts. 55 4.4 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing . 4.4.1 M-15 (With 20mm nominal size graded stone aggregate) 4.4.2 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 56 4.5 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement morta1:3 (1 cement : 3 sand) on exposed surfaces complete.(With 20mm nominal size graded stone aggregate) 57 4.6 Providing and fixing upto floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 sand) on exposed surfaces complete. 4.6.1 M-25 (With 20mm nominal size graded stone aggregate) 4.6.2 M-20 (With 20mm nominal size graded stone aggregate) 4.6.3 M-15 (With 20mm nominal size graded stone aggregate) 4.6.4 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. 58 4.7 Providing and fixing upto floor two level precast cement concrete solid block including hoisting and setting in position with 6mm thick cement plaster 1:3 (1 cement : 3 sand) on exposed surfaces complete : 4.7.1 M-15 (With 20mm nominal size graded stone aggregate) 4.7.2 M-10 (M 10) (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 59 4.8 Providing and Fixing upto floor two level pre cast concrete hollow block including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 cement : 3 sand) on exposed surfaces complete. 4.8.1 M-15 (With 20mm nominal size graded stone aggregate) 4.8.2 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. 60 4.9 Add extra for item no. 4.6, 4.7 and 4.8 above floor two level for every additional floor or part there of 61 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size). 62 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size). 63 4.12 Extra for providing and mixing water proofing material as per IS standard in cement concrete work quantity as prescribed by the manufacturer. 64 4.13 Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 65 4.14 Extra for concrete work in superstructure above floor two level for each floors or part thereof 66 4.15 Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.Note for item No. 4.15:- The quantity will be calculated by multiplying. The depth of centre of gravity shall be reckoned correct to 0.1m. 0.05m or more shall be taken as 0.1m and less than 0.05m ignored. 67 4.16 Extra for laying concrete in or under foul positions. 68 4.17 Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominal size graded stone aggregate.) 69 4.18 Extra for addition of synthetic polyester triangular fiber of length 12 mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/RCC/Flooring/ Water retaining structures by using 125 gms of synthetic polyester triangular fibre for 50 kgs cement used as per directions of Engineer-in- Charge. 70 4.19 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. 71 4.20 Providing and fixing up to floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 72 4.21 Providing and fixing up to floor two level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete . 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 73 4.22 Providing and fixing up to floor two level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 74 4.23 Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.Note : (1) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacemen to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC. 4.23.1 All works up to plinth level: 4.23.1.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.23.1.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.23.1.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 4.23.2 All works above plinth and upto floor two level 4.23.2.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.23.2.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.23.2.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 75 4.24 Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in- charge. 4.24.1 All works up to plinth level: 4.24.1.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.24.1.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.24.1.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 4.24.2 All works above plinth and upto floor two level 4.24.2.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.24.2.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.24.2.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 76 4.25 Plum Cement concrete 1:2:4 with 75% graded metal of maximum size 40 mm and 25% plum of 150mm size. 77 4.26 Providing and laying cement concrete in Sunken floors of WC, Toilet, Wash Area, etc with 1:5:10 (1 cement : 5 coarse sand (zone-3) : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering 78 5.1 Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.1 M-20 Grade Concrete 5.1.2 M-15 Grade Concrete 79 5.2 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: 5.2.1 M-20 Grade Concrete 80 5.3 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. 5.3.1 M-20 Grade Concrete 81 5.4 Providing and laying upto floor two level reinforced cement concrete (with20 mm nominal size graded stone aggregate) in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with Concrete grade. 5.4.1 M-20 Grade Concrete 82 5.5 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in arches, archribs, domes, vaults, shells, folded plate above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in Concrete grade. 5.5.1 M-20 Grade Concrete 83 5.6 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in chimneys, shafts, upto floor two level excluding the cost of centring, shuttering, finishing and reinforcement with 5.6.1 M-20 Grade Concrete 88 5.7 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in well-steining excluding the cost of centering, shuttering, finishing and reinforcement with 5.7.1 M-20 Grade Concrete 84 5.8 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in vertical and horizontal fins individually or forming box louvers, facias and eaves boards up to floor two level excluding the cost of centering, shuttering, finishing and reinforcement in M 20 –Grade Concrete 85 5.9 Centering and shuttering in cluding strutting, propping etc. and removal of form for: 5.9.1 Foundations, footings, bases of columns, etc. for concrete upto plinth level 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 Uptoplinthlevel. 5.9.2.2 Above plinth upto 3.6 m height from plinth level 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. 5.9.3 Suspended floors, roofs, landings, balconies and access platform. 5.9.4 Shelves(Cast in situ) 5.9.5 Lintels, beams, girders, bressumers and cantilevers 5.9.6 Columns, P i l l a r s , Piers, Abutments, Posts and Struts. 5.9.7 Stairs, (excluding landings) except spiral- Staircases. 5.9.8 Spiral staircases (including landing). 5.9.9 Arches, domes,vaults upto 6m span 5.9.10 Extra for arches, domes, vaults exceeding 6 m span 5.9.11 Chimneys and shafts 5.9.12 Coffer/waffle slab of any size or shape as shown in the drawing. 5.9.13 Well steining 5.9.14 Vertical and horizontal fins individually or forming Box louvers band, facias and eaves boards. 5.9.15 Extra for shuttering in circular work or any other geometrical shape (20% of respective centering and shuttering items). 5.9.16 Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. 5.9.17 Cornices and mouldings 5.9.18 Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. 5.9.19 Weather shade, Chajjas, corbels etc., including Edges. 5.9.20 Suspended floors, roofs, landings, balconies and Access platform. With water proof ply 12 mm thick. (item to be executed with prior permission of S.E. in case of B & R works and from Additional Project Director in case of PIU works) 5.9.21 Lintels, beams, columns, girders, bressumers and cantilevers with waterproof ply 12 mm thick (item to be executed with prior permission of S.E. in case of B&R works and from Additional Project Director in case of PIU works) 86 5.10 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof (Plan area to be measured) 5.10.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 87 5.11 Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete. 88 5.12 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 sand) etc. complete excluding plastering of the jambs, sills and soffits. 5.12.1 50 mm thick 5.12.2 40 mm thick 5.12.3 25 mm thick 89 5.13 Encasing rolled steel sections, in beams and columns, with cement concrete M 15 (1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size) including centering and shuttering complete but excluding cost of reinforcement. 80 5.14 Encasing rolled steel section in grillages with cement concrete M 15 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) including centering and shuttering but excluding cost of expanded metal and hangers. 91 5.15 Extra for providing and fixing expanded metal mesh of size 20x60mm and strands 3.25mm wide 1.6mm thick weighing 3.64 kg per sqm for encasing of rolled steel sections in beams, columns and grillages excluding cost of hangers. 92 5.16 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) 5.16.1 Mild steel and Medium Tensile steel bars. 5.16.2 Hard drawn steel wire 5.16.3 Cold twisted bars (CTD) 5.16.4 Hot rolled deformed bars 5.16.5 Hard drawn steel wire fabric 5.16.6 Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 93 5.17 Add extra for providing reinforcement above Floor two level for every additional floor or part thereof. 94 5.18 Providing and fixing in position copper plate as per design for expansion joints. 95 5.19 Providing and filling in position, blown bitumen in expansion joints. 96 5.20 Providing and filling in position bitumen mix filler of Proportion 80 kg. Of hot bitumen, 1 kg. Of cement and 0.25 cubic metre of sand for expansion joints. 97 5.21 Providing and filling gap in expansion joint between RCC/ Stone/Ceramic tiles/Granite/ Marble by providing silicon sealant over backer rod of approved quality weather sealant as per drawing and direction of engineer in charge up to 25mm width & 12 mm depth. 98 5.22 Providing and fixing in position bitumen impregnated fibre board conforming to IS: 1838 including cost of primer, sealing compound in expansion joints. 5. 22.1 12 mm thick 5. 22.2 25 mm thick 5. 22.3 50 mm thick 99 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design. 5. 23.1 Non-asbestos fibre cement board 6 mm thick as per IS: 14862. 5. 23.1.1 150mm wide. 5. 23.1.2 200mm wide. 5. 23.1.3 250mm wide. 5. 23.2 Aluminium fluted strips 3.15mm thick. 5. 23.2.1 150 mm wide. 5. 23.2.2 200 mm wide. 5. 23.2.3 250 mm wide. 5. 23.3 Stainless steel Grade 304 plate-1.0 mm thick 5. 23.3.1 150 mm wide. 5. 23.3.2 200 mm wide. 5. 23.3.3 250 mm wide. 100 5.24 Providing for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 101 5.25 Extra for laying reinforced cement concrete in or under water and/ or liquid mud including cost of pumping or bailing out water and removing slush etc., complete.Note- For Item No. 5.25:-The quantity will be calculated by multiplying the depth measured from the subsoil water level up to the centre of gravity The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under sub – soil water condition 102 5.26 Extra for laying reinforced cement concrete in or under foul positions. 103 5.27 Providing and laying in position machine batched, machine mixed cement concrete (BMC) of M-25 grade for reinforced cement concrete work using cement content as per approved mix design concrete without impairing strength and durability as per direction of Engineer-in charge and pumping of concrete to site of laying and finishing but excluding the cost of centering, shuttering, and reinforcement. (Note: - Minimum cement content is 330 kg/cum) and no extra payment for extra cement used as per mix design. 5.27.1 All works upto plinth level. 5.27.2 All works above plinth level and upto floor five level. 5.27.3 Add extra for each floor for all works above floor five level. 104 5.28 Extra for providing richer mixes of BMC design mix as per item no 5.27 upto plinth level and at all floor levels. (No extra payment for using extra cement as per requirement of mix design.) 5. 28.1 Providing M-25 grade concrete instead of M- 20 grade.(Note : minimum cement content is @ 330 kg/cum) 5. 28.2 Providing M-30 grade concrete instead of M- 25 grade.(Note : minimum cement content is @ 340 kg/cum) 5. 28.3 Providing M-35 grade concrete instead of M- 25 grade.(Note: : minimum cement content is @ 350 kg/cum) 5. 28.4 Providing M-40 grade concrete instead of M- 25 grade.(Note: minimum cement content is @ 360 kg/cum) 105 5.29 Providing and placing in position precast reinforced cement concrete waffle units square or rectangular as per design and shape for floors and roofs in M-20 –Grade Concrete (with graded stone aggregate 10mm nominal size. including provision of steel hooks for lifting and form work, handling, hoisting, centering and erection complete for all floor levels but excluding the cost of reinforcement. 106 5.30 Providing and laying in position ready mixed concrete (RMC) of M-25 grade for reinforced cement concrete work, using cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge.Note: Minimum cement content is @ 330 kg/cum. (No extra payment for using extra cement as per requirement of mix design.) 5.30.1 All works upto plinth level. 5.30.2 All works above plinth level and upto floor V level. 5.30.3 Extra for each additional floor for all works above floor five level 107 5.31 Extra for R.C.C. work above floor two level for each floors or part thereof. (except items 5.27 and 5.30) 108 5.32 Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. 5.32.1 Non pigmented wet curing compound 5.32.2 Pigmented wet curing compound. 109 5.33 Providing and fixing in position factory made precast RCC M-40 doors, windows and ventilator frames having excellent smooth finish, as per IS: 6523 with 6mm dia main reinforcement each polymer block having at least four holes for passing one or adjacent rebates to hold fast grill or steel bar, ventilator frame provided with grooves for louvers at an angel of 45 degree at spacing to block direct vision etc. complete, as per the direction of Engineer-in-charge. The cost of hold fast and cement concrete block of 1:3: 6 (1 Cement: 3 sand: 6 Graded stone aggregate 20mm nominal size) mix is also included in the item. 5. 33.1. Frame 125 mmx 60 mm (double rebate) 5. 33.2. Frame 100mmx 60 mm (Single rebate) 5. 33.3 Frame 85mmx 60 mm (Single rebate) 110 5.34 Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 sand). 111 5.35 Providing and fixing in position pre moulded compressible filler board made from polymer base in black color approved make conforming to the specifications having minimum density of 95 kg / cum, non- staining, with less than 1 percent water absorption and compression recovery of 93 percent minimum including cost of double sided adhesive tape, sealant etc. in expansion joints. 5. 35.1 12 mm thick 5. 35.2 25 mm thick. 5. 35.3 50 mm thick. 112 5.36 Providing and sealing the retaining wall expansion Joints with anodized aluminum extruded section of 135 mm × 3.1 mm confirm to alloy of 6063 T5/T6including fixing of an imported EPDM moisture Barrier conform to (American Society for Testing and Materials) 2240 & ASTM - G53 & 84 fixing with Epoxy adhesive confirm to ASTM C-881 complete in all respect as per manufacturer Drawing and specifications. With 5 year guarantee. 113 5.37 Providing and fixing sheet covering over expansion joints with iron screws as per design. Non- asbestos cement bonded particle board 6 mm thick as IS: 14276 5.37.1 150mm wide 5.37.2 200mm wide 5.37.3 250mm wide 114 5.38 Providing & laying in position Prestressing steel strands (low relaxation) on hollow core bed by using mechanical pulling arrangement like Rabbit/ Bed master including all accessories for Stressing &destressing operations as per approved make conforming to IS1343 & grade FY-1860 etc, complete as per drawings and direction of Engineer -in- charge. 115 5.39 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In- Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer - inCharge. (Material shall confirm to ASTM 6063). 5. 39.1 Floor Joint of 100 mm gap 5. 39.2 Floor Joint of 150 mm gap 5. 39.3 Floor Joint of 200 mm gap 116 5.40 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 5. 40.1 Wall Joint of 100 mm gap 5. 40.2 Wall Joint of 150 mm gap 5. 40.3 Wall Joint of 200 mm gap 117 5.41 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members with, self aligning and self centeringarragement support plates asper ASTM B221-02. . The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 5.41.1 Roof Joint for 100 mm gap 5.41.2 Roof Joint for 150 mm gap 5.41.3 Roof Joint for 200 mm gap 118 5.42 Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100gm/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work) 119 6.1 Brick work with well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process, crushing strength not less than 40kg /cm2 and water absorption not more than 15% in foundation and plinth i/c curing etc. complete. 6.1.1 Cement mortar 1:4 (1 cement : 4 sand) 6.1.2 Cement mortar 1:6 (1 cement : 6 sand) 120 6.2 Brick work with well burnt chimney bricks in bulls patent trench kiln manufactured by ghol process ,crushing strength not less than 40kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level i/c curing etc. complete. 6.2.1 Cement mortar 1:4 (1 cement : 4 sand) 6.2.2 Cement mortar 1:6 (1 cement : 6 sand) 121 6.3 Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. 6.3.1 Cement mortar 1:4 (1 cement : 4 sand) 6.3.2 Cement Mortar 1:6 (1 cement:6 sand). 122 6.4 Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. 6.4.1 Cement mortar 1:4 (1 cement : 4 sand) 6.4.2 Cement Mortar 1:6 (1 cement:6 sand). 123 6.5 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. 6.5.1 Cement mortar 1:4 (1 cement : 4 sand) 6.5.2 Cement Mortar 1:6 (1 cement: 6 sand). 124 6.6 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. 6.6.1 Cement mortar 1:4 (1 cement : 4 sand) 6.6.2 Cement Mortar 1:6 (1 cement : 6 sand) 125 6.7 Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : 6.7.1 Having 100 kg / cm2 average compressive strength. 6.7.1.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.1.2 Cement mortar 1:6 (1 cement : 6 sand) 6.7.2 Having 75 kg / cm2 average compressive strength. 6.7.2.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.2.2 Cement mortar 1:6 (1 cement : 6 sand) 6.7.3 Having 50 kg / cm2 average compressive strength. 6.7.3.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand) 126 6.8 Brick work with calcium silicate bricks machine moulded conforming to IS:4139, having 100 kg/cm2 average compressive strength in super structure above plinth level upto floor II level in : 6.8.1 Cement mortar 1:4 (1 cement : 4 sand) 6.8.2 Cement mortar 1:6 (1 cement : 6 sand) 127 6.9 Brick work with extruded burnt fly ash clay sewer bricks (Conforming to IS: 4885 ) in foundation and plinth : Cement Mortar 1:4 ( 1 cement : 4 sand) 128 6.10 Brick work with extruded burnt fly ash clay sewer bricks (conforming to IS: 4885) in archesin foundation and plinth including centering and shuttering complete in cement mortar 1:3 (1 cement: 3 sand). 129 6.11 Extra for brick work in superstructure above floor two levels for each additional floor or part thereof respective item. 130 6.12 Providing half brick masonry with well burnt chimney bricks in bull patent trench kiln manufactured by ghol process crushing strength not less than 40 kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level. 6.12.1 Cement mortar 1:3 (1 cement : 3 sand) 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) 131 6.13 Providing half brick masonry with well burnt chimney bricks in bull pattern trench kiln crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level. 6.13.1 Cement mortar 1:3 (1 cement : 3 sand) 6.13.2 Cement mortar 1:4 (1 cement : 4 sand) 132 6.14 Providing half brick masonry with well burnt open bhatta bricks crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level 6.14.1 Cement mortar 1:3 (1 cement : 3 sand) 6.14.2 Cement mortar 1:4 (1 cement : 4 sand) 133 6.15 Half brick masonry with fly ash lime Gypsum bricks (FALG bricks) conforming to IS: 12894, in super structure above plinth and upto floor two level. 6.15.1 Having 100 kg/cm2 average compressive strength. 6.15.1.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.1.2 Cement mortar 1 : 4 (1 cement : 4 sand) 6.15.2 Having 75 kg/cm2 average compressive strength. 6.15.2.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.2.2 Cement mortar 1 : 4 (1 cement : 4 sand) 6.15.3 Having 50 kg/cm2 average compressive strength. 6.15.3.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.3.2 Cement mortar 1 : 4 (1 cement : 4 sand) 134 6.16 Extra for half brick masonry in superstructure, above floor two level for every floor or part thereof respective item. 135 6.17 Extra for providing and placing in position 2 Nos. 8mm dia. M.S. bars at every third course of in half brick masonry. 136 6.18 Honey-comb brick work 10 cm thick with well burnt chimney bricks manufactured by ghol process crushing strength not less than 40kg /sqcm and water absorption not more than 15% in cement mortar 1:4 (1 cement : 4 sand). 137 6.19 Extra for forming cavity 5cm to 7.5cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. Ties 300mm long of 25x3mm section at not less than 3 ties per sqm as per approved design 138 6.20 Brick work in plain arches in superstructure including centering and shuttering complete with chimney bricks having crushing strength not less than 40kg /cm2 and water absorption not more than 15% in cement mortar 1:3 (1 cement : 3 sand). 139 6.21 Brick work in gauged arches in superstructure in cement mortar 1:3 (1 cement : 3 sand) including centering and shuttering complete, with chimney bricks having crushing strength not less than 40kg /cm2 and water absorption not more than 15% 140 6.22 Providing half brick masonry with kiln burnt clay bricks of 40kg /cm2 and water absorption not more than 15% in cement mortar 1:3 (1 Cement : 3 sand) in superstructure for closing cavity 5 to 7.5 cm wide in cavity wall complete with 10 cm wide bitumen felt type 3 grade 1. 141 6.23 Extra for laying brick work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.NOTE: - The quantity will be calculated by multiplying the depth measured from sub - soil water level up to the centre of gravity of brick work in cum executed under the sub - soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. 142 6.24 Extra for laying brick work in or under foul position. 143 6.25 Providing and laying cellular concrete blocks masonry having density ranging from 800kg/m3 in super structure above plinth level up to floor two level in cement mortar 1:4 (1 cement: 4 sand) The nominal dimensions of the concrete blocks shall be as follows in additional block shall be of half lengths of 200, 250 or 300 mm to correspond to the full lengths. The size of the blocks specified other than those specified may also be used. 144 6.26 Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonry, using AAC blocks (Size length 300, 400, 500, 600 mm Height 200, 250, 300 mm Width 100, 150, 200, 250 mm) conforming to IS 2185 PART 3, having compressive strength not less than 4 MPa (Grade II) in super structure, blocks jointed with approved block laying polymer modified adhesive mortar as per ASTM international standard including raking out joints. Vertical bands shall be placed along jams (vertical member of chowkhats) and extend upto lintel levels to arrest cracking at corner openings. RCC bands shall be measured with AAC block masonry. Rates include all materials including steel bars, wastages, scaffolding and all labour etc. complete. 6.26.1 AAC Masonry in polymer modified mortar 145 6.27 Extra for AAC masonry work in superstructure above floor two level for each additional floor or part thereof 146 6.28 Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced roof slabs, lintels and chhajjas as per IS: 6073 -2006 grade D specifications (dry density, without steel, 550 kg/m3 to 650 kg/m3 and minimum compressive strength 3.5 N/mm2) reinforcement steel provided inside AAC slab, lintel and chhajja shall be ascertained on the basis of manufacturer’s certificate and also by random destructive testing done by engineer-in-charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Deflection & ultimate load test for AAC reinforced roof slab and lintel shall be as per annex. B of IS: 6073 -2006 and criteria for conformity and sampling shall be as per clause-13 of IS: 6073 -2006. 147 6.29 Precast autoclaved aerated concrete (AAC) reinforced wall panels:- Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced wall panels as per IS:6072 -1972 grade D (dry density, without steel, 550 kg/m3 to 650 kg/m3 and inside AAC panels. Quantity of reinforcement steel in AAC panels shall be ascertained on the basis of certificate of the manufacturer and also by random destructive testing by engineer-in- charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Cost of reinforcement inside AAC panels shall be paid separately. 148 6.30 Add extra for AAC wall panels, roof slabs, lintels and chhajjas above floor two level for each additional floor as per item no 6.29 and 6.30. 149 6.32 Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) 6.32.1 From ground level upto plinth level 6.32.2 Above plinth level upto floor II level 150 6.33 Brick work with modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12mm deep complete from ground level up to plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) 6.33.1 From ground level upto plinth level 6.33.2 Above plinth level upto floor II level 151 6.34 Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturer’s specifications in superstructure above plinth level up to floor two level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2 152 6.35 Extra for Gypsum panel Partitions in superstructure above floor two level for every four floors or part thereof. 153 7.1 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement :6 sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : 7.1.1 Cement mortar 1:6 (1 cement : 6 sand) 154 7.2 Random rubble masonry with hard stone in superstructure above plinth level and upto floor two level, including leveling up with cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like. 7.2.1 Cement mortar 1:6 (1cement: 6 sand). 155 7.3 Extra for random rubble masonry with hard stone in superstructure above floor two level for every floors or part thereof 156 7.4 Extra for random rubble masonry with hard stone in : 7.4.1 Square or rectangular pillars 7.4.2 Circular pillars. 157 7.5 Extra for random rubble masonry with hard stone curved on plan for a mean radius not exceeding 6 m. 158 7.6 Coursed rubble masonry (1st or 2nd sort) with hard stone in foundation and plinth. 7.6.1 Cement mortar 1:6 (1 cement : 6 sand) 7.6.2 Cement mortar 1:6 (1 cement : 6 sand) 159 7.7 Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor two level. 7.7.1 Masonry work (first sort) in cement mortar 1:6 (1 cement : 6 sand) 7.7.2 Masonry work (second sort) , in cement mortar 1:6 (1 cement : 6 sand) 160 7.8 Extra for coursed rubble masonry with hard stone (first or second sort) in superstructure above floor two level for every floors or part thereof 161 7.9 Extra for coursed rubble masonry with hard stone (first or second sort) in : 7.9.1 Square or rectangular pillars 7.9.2 Circular pillars. 7.9.3 Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. 162 7.10 Stone work in plain ashlar masonry in super structure upto floor two level in cement mortar 1:6 (1 cement : 6 sand) including pointing with cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the sand stone shade : 7.10.1 One face dressed. 7.10.1.1 Red sand stone 7.10.1.2 White sand stone 7.10.2 Both face dressed. 7.10.2.1 Red sand stone. 7.11.2.2 White sand stone 163 7.11 Stone work plain ashlar masonry in arches in super structure upto floor two level in cement mortar 1:3 (1 cement: 3 sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.11.1 One face dressed. 7.11.1.1 Red sand stone 7.11.1.2 White sand stone 7.11.2 Both face dressed. 7.11.2.1 Red sand stone. 7.11.2.2 White sand stone 164 7.12 Stone work plain ashlar masonry in domes, in super structure upto floor two level in cement mortar 1:3 (1 cement: 3 sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.12.1 One face dressed 7.12.1.1 Red sand stone 7.12.1.2 White sand stone 7.12.2 Both face dressed. 7.12.2.1 Red sand stone. 7.12.2.2 White sand stone. 165 7.13 Stone work ashlar masonry punched (ordinary) in superstructure above plinth level and upto floor two level in cement mortar 1:6 (1 white cement: 6 sand) including pointing with cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.13.1 Red sand stone one face punched. 7.13.2 Red sand stone both face punched 7.13.3 White sand stone one face punched. 7.13.4 White sand stone double face punched 166 7.14 Extra for stone work, plain ashlar or ashlar punched above floor two level for every floor or part thereof. 167 7.15 Extra for plain ashlar or ashlar punched in : 7.15.1 Square or rectangular pillars 168 7.16 Extra for stone work; plain ashlar or ashlar punched in curved on plan with a mean radius not exceeding 6 m. 169 7.17 Extra for additional cost of centering for arches exceeding 6m span including all strutting, bolting, wedging etc. And removal (area of soffit to be measured). 170 7.18 Stone work sunk or moulded or sunk and moulded upto floor Two level in cement mortar 1:6 (1cement : 6 sand) including pointing with white cement mortar 1:2 (1 white : 2 marble dust) with an admixture of pigment matching the stone shade : 7.18.1 Red sand stone 7.18.2 White sand stone 171 7.19 Extra for stone work sunk or moulded or sunk and moulded or carved in : 7.19.1 Triangular or Square or rectangular pillars 7.19.2 Circular or polygonal pillars 172 7.20 Extra for stone work sunk or moulded in cornices. 173 7.21 Stone work (machine cut edges) for wall lining etc. (veneer work) up to 10 meter height backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 sand) including pointing in white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of clamps which shall be paid for separately): 7.21.1 Red sand stone - exposed face fine dressed with rough backing. 7.21.1.1 70 mm thick. 7.21.1.2 60 mm thick. 7.21.1.3 50 mm thick 7.21.1.4 40 mm thick. 7.21.1.5 30 mm thick. 7.21.2 Red sand stone - Exposed face machine cut and table rubbed with rough backing. 7.21.2.1 70 mm thick. 7.21.2.2 60 mm thick. 7.21.2.3 50 mm thick 7.21.2.4 40 mm thick. 7.21.2.5 30 mm thick. 7.21.3 White sand stone - exposed face fine dressed with rough backing. 7.21.3.1 70 mm thick. 7.21.3.2 60 mm thick. 7.21.3.3 50 mm thick 7.21.3.4 40 mm thick. 7.21.3.5 30 mm thick. 7.21.4 White sand stone - Exposed face machine cut and table rubbed with rough backing. 7.21.4.1 70 mm thick. 7.21.4.2 60 mm thick. 7.21.4.3 50 mm thick 7.21.4.4 40 mm thick. 7.21.4.5 30 mm thick. 174 7.22 Extra for stone work (veneer work) curved on plan with a mean radius not exceeding 6 m. 175 7.23 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement :2 sand) including making the necessary chases in stone and holes in walls wherever required. 176 7.24 Providing and fixing stone dowels of size 10x5x2.5cm cut to double wedge shape as per design in cement mortar 1:2 (1 cement : 2 sand) including making the necessary chases 177 7.25 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 sand) including making the necessary chases. 178 7.26 Providing and fixing sloping chajja of stone 40 mm thick and upto 80 cm wide beyond the wall as measured along the slope in cement mortar 1:4 (1 cement : 4 sand) including pointing in cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the stone shade: 7.26.1 Red sand stone: With common burnt clay bricks of 25 kg/cm2 compressive strength. 7.26.2 White sand stone: With common burnt clay bricks of 25 kg/cm2 compressive strength. 179 7.27 Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 sand) including pointing in white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the stone shade: 7.27.1 Red sand stone 7.27.2 White sand stone 180 7.28 30mm red sand stone sun-shade (chisel-dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement: 4 sand) including finishing complete. 181 7.29 Providing and fixing red sand stone brackets 55x22.5x45cm sunk and moulded including providing and fixing with 4 Nos. gun metal cramp 25x6mm 30 cm long and dowel bars 7.5 cm long 6 mm dia as per design. 182 7.30 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 7.30.1 Red sand stone 7.30.2 White sand stone 183 7.31 Providing and fixing stone jali 40mm thick throughout in cement mortar 1:3 (1cement :3 sand) including pointing in white cement mortar 1:2 (1white cement: 2stone dust) with an admixture of pigment , matching the stone shade, jali slab without any chamfers etc. 7.31.1 Red sand stone 7.31.2 White sand stone 184 7.32 Extra for laying stone work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.NOTE: - The quantity will be calculated by multiplying the depth measured from sub - soil water level up to the centre of gravity of stone work in cum executed under the sub - soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. 185 7.33 Extra for laying stone work in or under foul position. 186 7.34 Wall lining butch work upto 10m height with red/ white sand stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width 75mm thick strips i/c 12mm thick bed of cement mortar 1:3 (1 Cement : 3 sand) i/c ruled pointing in cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in- charge. 187 7.35 Stone work ( machine cut edges) for wall lining upto 10 m height etc. (Veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 Cement : 3 sand) and jointed with Cement mortar 1:2 (1 cement : 2 marble dust) including rubbing and polishing complete. (To be secured to the backing by means of cramps which shall be paid for separately) 7.35.1 25mm thick Kota stone slabs exposed face dressed and rubbed. 7.35.2 25mm thick Dholpur stone slabs exposed face dressed and rubbed. 7.35.3 20 to 25mm thick kota stone slabs exposed slab not dressed and rubbed. 7.35.4 20 to 25mm thick Dholpur stone/shivpuri stone not dressed and rubbed. 188 7.36 Stone tile work with 8mm thick mirror polished and machine cut edge for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 sand), including pointing in white cement with an admixture of pigment to match the stone shade. 7.36.1 Granite stone of any colour and shade 7.36.2 Raj Nagar plain white marble/ Udaipur green marble/ Zebra black marble 189 7.37 Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 190 7.38 Providing and fixing dry stone cladding upto 10 metre height with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and/ or with the help of cramps, pins etc. And sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins. shall be paid for separately.) 7.38.1 Red sand stone. 7.38.2 White sand stone 191 7.39 Providing and fixing structural steel frame (for dry stone cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/rectangular tube in the required pattern as per architectural drawing including including drilling necessary steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution).The frame work shall be fixed in true horizontal and vertical lines/ planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel clamps shall be paid for separately and nothing extra shall be paid.) 192 7.40 Providing and fixing adjustable stainless steel clamps of approved quality and of required shape and size adjustable with stainless steel nuts bolts and washer (total weight not less than 260 gms) for dry stone cladding fixed on frame 193 8.1 Providing and supplying aluminium extruded tubular and other aluminium sections frame work as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coated of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). 194 8.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of aluminium structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels.. (A) Structural analysis anddesign and preparation of shopdrawings for the specified designloads conforming to IS 875 partIII (the system must passed theproof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sectionsBfor fixing glazing panels of various thicknesses, aluminum cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals,microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage andprotection against fire hazard including (B) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminum alloy of 6005 T5 brackets of required sizes, sections and profiles etc. toaccommodate 3 Dimentional movement for achieving perfect verticality and fixing structuralglazing system rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contactswith nuts and washers etc. of stainless steel grade 316, of the required capacity and in requirednumbers.(C) Providing and filling, two part pump filled, structural silicone sealant and one partweather silicone sealant compatible with the structural silicone sealant of required bitesize in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(D) Providing and fixing in position flashings of solid aluminum sheet 1 mm thick andof sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight(E) Making provision for drainage of moisture/ water that enters the curtain glazing systemto make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary 195 8.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.8.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. 196 8.4 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. 197 8.5 Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi - rigid, inorganic, non- combustible fibre glass wool insulation 50 mm thick having density 48 kg/m3, conforming to IS: 8183 and BS: 3958 Part 5.The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non- woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm/sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. 198 8.6 Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., included in cost of relevent Item). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 199 8.7 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel (ACP) Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. upto two decimal places. 8.7.1 4 mm thick alumminium composite pannel material consisting of 3 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.5mm thick) 8.7.2 4 mm thick alumminium composite pannel material consisting of 3.5 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.25mm thick) 8.7.3 3 mm thick alumminium composite pannel material consisting of 2.5 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.25mm thick) 200 8.8 Design, supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as pr IS 875 (Part- III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider and other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete.For the purpose of payment actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured., 201 8.9 Providing and fixing aluminium magnesium alloy (FACADE) wall cladding system consisting of panels 200mm wide x 17mm deep x 0.5mm thick of maximum length of 6.0 mtr. coil coated on a continuous paint line double baked and roll formed from centre to centre at a distance of maximum 1.20 mtr. The stringer shall be fixed to a suitable rigid structure. All panels shall be achromatised for maximum bond between metal and paint, enamelled twice under high temperature one side with full primer and the other side (inner side) with a primer coat on a continuous paint line, and fixed as per the direction of the Engineer-in-Charge. 202 8.10 Providing and fixing Aluminium Magnesium alloy Plain Panel Sun Louvres of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length upto 6 mtrs coil coated on a continuos paint line double baked between metal and paint, enamelled twice under high temperature one side with full primer and finish, the other side (inner side) with a primer coat and Skin Coat on a Continuos Paint Line.Note: - 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. upto two decimal places. 203 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood 9.1.2 Sal wood 9.1.3 Kiln Head wood seasoned and chemically treated hard wood (Haldu, Kail, Bija wood.) 9.1.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 9.1.4.1 Frame of size 100mmX60mm single or double rebate 9.1.4.2 Frame of size 120mmX60mm double rebate. 205 9.2 Providing laminated veneer lumber conforming to IS:14616 and TAD -15: 2001(Part-B) in factory made frames of doors, windows, clerestory windows and other frames, wrought framed and fixing in position with hold fast lugs or with dash fasteners of required dia and length ( hold fast lugs or dash fastener shall be paid for separately). 206 9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position ( with necessary stainless steel screw) 9.3.1 Sal wood 9.3.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. 9.3.3 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 207 9.4 Extra for additional labour wood work in circular shape, such as in frames of fan light : 9.4.1 Second class teak wood 9.4.2 Sal wood 9.4.3 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.4.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 208 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws excluding, panelling/glazing which will be paid for separately, all complete as per direction of Engineer-in-charge. 9.5.1 Second class teak wood 9.5.1.1 35 mm thick shutters 9.5.1.2 30 mm thick shutters 9.5.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. 9.5.2.1 35 mm thick shutters 9.5.2.2 30 mm thick shutters 9.5.3 Kiln seasoned selected planks of sheesham wood. 9.5.3.1 35 mm thick shutters 9.5.3.2 30 mm thick shutters 9.5.4 Factory made Kiln seasoned chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood shutters 9.5.4.1 35 mm thick 9.5.4.2 30 mm thick 209 9.6 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: 9.6.1 Second class teak wood 9.6.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood 9.6.3 15mm thick Factory made Kiln seasoned, chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood. 9.6.4 Ply wood 5 ply, 9 mm thick : 9.6.4.1 Decorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type. 9.6.4.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type 9.6.5 Ply wood 7 ply, 9 mm thick : 9.6.5.1 Decorative plywood both side decorative veneer (Type- I) conforming to IS 1328 BWR type. 9.6.5.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-1) conforming to IS 1328 BWR Type 9.6.6 Particle Board 12 mm thick 9.6.6.1 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. 9.6.6.2 Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. 9.6.6.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked. 9.6.6.4 Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS: 12823 marked. 9.6.6.5 Coir Veneer Board (conforming to IS 14842) 12 mm thick 9.6.7 Float glass panes 9.6.7.1 4 mm thick glass pane (weight not less than 10 kg/sqm) 9.6.7.2 5 mm thick glass pane (weight not less than 12.5 kg/sqm) 9.6.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading 9.6.8.1 4mm to 5mm thick integral PVC form sheet with Celluka finish surface on both side with density not less than 600 kg/cum 9.6.8.2 4mm to 5mm thick laminated PVC form sheet with density not less than 600 kg/cum, laminated on both sides by 0.12 mm thick laminated sheet with density not less than 1400 kg/cum 210 9.7 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B) including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of Engineer-in- charge and panelling with panels of: 9.7.1 12mm thick plain grade - 1, medium density flat pressed three layer particle board FPT - I or graded wood particle board FPT - I IS : 3087 marked bonded with BWP type synthetic resin adhesive as per IS : 848 : 9.7.2 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade - 1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre- lamination conforming to IS : 12823 Grade 1, Type - II marked: 9.7.3 12 mm thick one side pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and prelamination conforming to IS : 12823 Grade -1, Type II marked: 211 9.8 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 9.8.1 Second class teak wood 9.8.1.1 35 mm thick 9.8.1.2 30 mm thick 9.8.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood 9.8.2.1 35 mm thick 9.8.2.2 30 mm thick 9.8.3 Kiln seasoned selected planks of sheesham wood. 9.8.3.1 35 mm thick 9.8.3.2 30 mm thick 9.8.4 Factory made Kiln seasoned chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood 9. 8.4.1 30 mm thick shutters 9. 8.4.2 35 mm thick shutters 212 9.9 Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B) , using 4mm thick float glass panes for doors, windows and clerestory windows including ISI marked fixing with M.S. pressed butt hinges bright finished of required size with necessary screws as per directions of Engineer-in- charge. 30 mm thick shutters. 213 9.10 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) 9.10.1 5 mm thick instead of 4 mm thick. 9.10.2 10 to 12 mm float glass 9.10.3 5.5 mm safety glass 9.10.4 10-12mm safety glass 214 9.11 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 215 9.12 Deduct for providing pin headed glass panes instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory windows, shutters (Area of opening for glass panes excluding portion inside rebate shall be measured). 216 9.13 Extra for S.S, hinges providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). 217 9.14 Deduct for not providing hinges in doors, windows or clerestory window shutters with : 9.14.1 Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. 9.14.2 ISI marked M.S. pressed butt hinges bright finished of required size For 2nd class teak wood and other class of wood shutters. 218 9.15 Providing and fixing 25 mm thick Second class teak wood shutters using 4mm float glass for cup board etc. : 9.15.1 Panelled or panelled and glazed shutters : 9.15.1.1 Using ISI marked anodised aluminium butt hinges with necessary screws. 9.15.1.2 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 9.15.2 Glazed shutters : 9.15.2.1 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. 9.15.2. 2nd class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 219 9.16 Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately) : 9.16.1 12 mm thick 9.16.2 18 mm thick 220 9.17 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 9.17.1 18 mm thick 9.17.2 25 mm thick 221 9.18 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutter. 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.18.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.18.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws. 222 9.19 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.19.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.19.3 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 223 9.20 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only. 224 9.21 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 225 9.22 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : 9.22.1 Rectangular or square. 9.22.2 Circular. 226 9.23 Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). 227 9.24 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 228 9.25 Providing and fixing wire gauze shutters using galvanised M.S. wire gauze of average width of aperture 1.4mm in both direction with wire of dia. 0.63 mm for doors, windows and clerestory windows with hinges and necessary screws: 9.25.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.1.1 Second class teak wood. 9.25.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.1.3 Kiln seasoned selected class of sheesham wood. 9.25.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.2.1 Second class teak wood. 9.25.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.2.3 Kiln seasoned selected class of sheesham wood. 9.25.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.3.1 Second class teak wood. 9.25.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.3.3 Kiln seasoned selected class of sheesham wood. 9.25.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.4.1 Second class teak wood. 9.25.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.4.3 Kiln seasoned selected class of sheesham wood. 229 9.26 Providing and fixing wire gauge laminated veneer lumber shutters conforming to IS : 14616, and as per TADS 15 :2001 (Part B) using galvanised wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm as per IS :1568 for doors, windows and clerestory windows including ISI marked M.S. pressed fixing with butt hinges bright finished of required size with necessary screws as per directions of Engineer-in-charge: 9.26.1 35 mm thick shutters 9.26.2 30 mm thick shutters 230 9.27 Providing 50x50x50mm 2nd class teak wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement : 3 sand) and making good the walls etc. 231 9.28 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 9.28.1 25 mm long 9.28.2 32 mm long 9.28.3 40 mm long 9.28.4 50 mm long 9.28.5 60 mm long 232 9.29 Providing and fixing 2nd class teak wood plain lining tongued and grooved including wooden plugs complete with necessary screws and priming coat on unexposed surface. 9.29.1 40 mm thick. 9.29.2 25 mm thick. 9.29.3 20 mm thick 9.29.4 12 mm thick 233 9.30 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre- laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 9.30.1 12 mm thick 9.30.2 18 mm thick 9.30.3 25 mm thick 234 9.31 Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 235 9.32 Providing and fixing plywood 4 mm thick one side decorative veneer conforming to IS: 1328 (type-1) for plain lining / cladding with necessary screws, priming coat on unexposed surface with: Decorative veneer facings of approved manufacture. 236 9.33 Providing and fixing 4mm thick coir veneer board, ISI marked IS: 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. 237 9.34 Providing and fixing skirting of Pre- laminated with (one side decorative and other side balancing lamination) flat pressed, 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : 9.34.1 18 mm thick 9.34.2 25 mm thick 238 9.35 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 9.35.1 2nd class teak wood 9.35.1.1 50x12 mm 9.35.1.2 50 x 20 mm 9.35.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.35.2.1 50x12 mm 9.35.2.2 50x20 mm 239 9.36 Providing and fixing plain jaffri of 35x10 mm laths placed 35 mm apart (frames to be paid separately) including fixing 50x12 mm beading complete with : Second class teak wood. 240 9.37 Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked,, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with Haldu, Kail, Bija wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. 241 9.38 Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS: 14842, including top cover of 6 mm coir veneer board, nickle plated brackets, including fixing with 25x3 mm M.S. Flat 10 cm long fixed to pelmet with Haldu, Kail, Bija wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. 242 9.39 Extra for using veneered particle board conforming to IS 3097 Grade I, in item of pelmet 18mm thick 150mm wide. 9.39.1 Non decorative veneer on both sides. 9.39.2 Particle board with decorative veneering on both sides. 243 9.40 Providing and fixing teak wood lipping of size 25x3 mm in pelmet. 244 9.41 Providing and fixing of 1.25 mm thick chromium plated brass plate, with two chromium plated curtain rods brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 9.41.1 12 mm dia. 9.41.2 20 mm dia. 9.41.3 25 mm dia. 245 9.42 Providing and fixing nickel plated curtain rods M.S. pipe with nickel plated brackets : 9.42.1 20 mm dia (heavy type) 9.42.2 25 mm dia (heavy type) 246 9.43 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.43.1 Fixed to steel windows by welding. 9.43.2 Fixed to openings /wooden frames with rawl plugs screws etc. 247 9.44 Providing and fixing expanded metal 20x60 mm strands 3.25 mm wide and 1.6 mm thick for windows etc. including 62 x19 mm beading of II nd class teak wood and priming coat with approved steel primer all complete. 248 9.45 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 249 9.46 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete. 9.46.1 With 2nd class teak wood beading 62x19 mm. 9.46.2 With 12 mm mild steel U beading. 250 9.47 Deduct for fixing 75x25 mm hard drawn steel wire fabric of weight not less than 7.75 Kg. per sqm in panelled and glazed door and window shutter instead of glass sheet 4 mm thick. 251 9.48 Providing 40x5 mm flat (iron hold fast 40 cm long) (0.628 kg) including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) 252 9.49 Providing wooden beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with : 9.49.1 Sal wood. 9.49.2 Haldu, Kail, Bija wood. 253 9.50 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : 9.50.1 125x65x2.12 mm 9.50.2 100x58x1.90 mm 9.50.3 75x47x1.70 mm 9.50.4 50x37x1.50 mm 254 9.51 Providing and fixing IS : 1341 marked M.S. heavy weight butt hinges with necessary screws etc. complete : 9.51.1 125x90x4.00 mm 9.51.2 100x75x3.50 mm 9.51.3 75x60x3.10 mm 9.51.4 50x40x2.50 mm 255 9.52 Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 9.52.1 125x65x2.12 mm 9.52.2 100x58x1.90 mm 9.52.3 75x47x1.70 mm 9.52.4 50x37x1.50 mm 256 9.53 Providing and fixing ISI marked oxidised M.S. pressed Parliamentary hinges with necessary screws etc. complete : 9.53.1 150x125x27x2.80 mm 9.53.2 125x125x27x2.80 mm 9.53.3 100x125x27x2.80 mm 9.53.4 75x100x20x2.24 mm 257 9.54 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete : 9.54.1 150 mm 9.54.2 125 mm 9.54.3 100 mm 258 9.55 Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. 9.55.1 150 mm 9.55.2 125 mm 9.55.3 100 mm 259 9.56 Providing M.S. Piano hinges ISI marked IS: 3818 finished with nickel plating and fixing with necessary screws etc., complete. 9.56.1 Overall width 35 mm. 9.56.2 Overall width 50 mm. 9.56.3 Overall width 65 mm. 260 9.57 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: 9.57.1 300x16 mm 9.57.2 250x16 mm 261 9.58 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.58.1 250x10 mm 9.58.2 200x10 mm 9.58.3 150x10 mm 9.58.4 100x10 mm 262 9.59 Providing and fixing ISI marked 85x42mm oxidised M.S. pull bolt lock conforming to IS: 7534 with necessary screws bolts, nut and washers etc. complete 263 9.60 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete : 9.60.1 300x20x6 mm 9.60.2 250x20x6 mm 264 9.61 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 9.61.1 125 mm 9.61.2 100 mm 9.61.3 75 mm 265 9.62 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : 9.62.1 150 mm 9.62.2 115 mm 9.62.3 90 mm 266 9.63 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 9.63.1 300 mm weighing not less than 200 gms. 9.63.2 250 mm weighing not less than 150 gms. 9.63.3 200 mm weighing not less than 120 gms. 267 9.64 Providing and fixing oxidised M.S. Safety chain with necessary fixtures for doors. (Weighing not less than 450 gms.) 268 9.65 Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete: 9.65.1 300x16 mm 9.65.2 250x16 mm 269 9.66 Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.66.1 250x10 mm 9.66.2 200x10 mm 9.66.3 150x10 mm 9.66.4 100x10 mm 270 9.67 Providing and fixing ISI marked 85x42mm stainless steel pull bolt lock with necessary screws bolts, nut and washers etc. complete. 271 9.68 Providing and fixing ISI marked stainless steel door latches with screws etc. complete : 9.68.1 300x20x6 mm 9.68.2 250x20x6 mm 272 9.69 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : 9.69.1 125 mm 9.69.2 100 mm 9.69.3 75 mm 273 9.70 Providing and fixing stainless steel hasp and staple (safety type) conforming to IS specification with necessary screws etc. complete : 9.70.1 150 mm 9.70.2 115 mm 9.70.3 90 mm 274 9.71 Providing and fixing stainless steel casement stays (straight peg type) conforming to IS specification with necessary screws etc. complete. 9.71.1 300 mm weighing not less than 200 gms. 9.71.2 250 mm weighing not less than 150 gms. 9.71.3 200 mm weighing not less than 120 gms. 275 9.72 Providing and fixing stainless steel safety chain with necessary fixtures for doors. Conforming to IS specification (Weighing not less than 450 gms.) 276 9.73 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 9.73.1 125x64x1.90 mm 9.73.2 100X58X1.90 mm 9.73.3 75x47x1.80 mm 9.73.4 50x37x1.50 mm 277 9.74 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 9.74.1 125x64x2.50 mm 9.74.2 100x60x2.50 mm 9.74.3 75x50x2.50 mm 278 9.75 Providing and fixing 50 mm Stainless steel cup board or wardrobe knob with necessary screws (best make of approved quality) 279 9.76 Providing and fixing Stainless steel hanging type floor door stopper with necessary screws, etc. complete. 280 9.77 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 9.77.1 125x85x5.5 mm (heavy type) 9.77.2 125x70x4 mm (ordinary type) 9.77.3 100x85x5.5 mm (heavy type) 9.77.4 100x70x4 mm (ordinary type) 9.77.5 75x65x4 mm (heavy type) 9.77.6 75x40x2.5 mm (ordinary type) 9.77.7 50x40x2.5 mm (ordinary type) 281 9.78 Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete : 9.78.1 150x125x27x5 mm 9.78.2 125x125x27x5 mm 9.78.3 100x125x27x5 mm 9.78.4 75x100x20x3.2 mm 282 9.79 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 9.79.1 400x10 mm 9.79.2 250x10 mm 9.79.3 200x10 mm 9.79.4 150x10 mm 9.79.5 100x10 mm 283 9.80 Providing and fixing bright finished brass door latch with necessary screws etc. complete. 9.80.1 300x16x5 mm 9.80.2 250x16x5 mm 284 9.81 Providing and fixing bright finished brass handles with necessary screws etc. complete. 9.81.1 125 mm 9.81.2 100 mm 9.81.3 75 mm 285 9.82 Providing and fixing bright finished brass sliding door bolts with nuts and screws etc complete. 9.82.1 300x16mm 9.82.2 250x16mm 286 9.83 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 287 9.84 Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of approved quality). 288 9.85 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 289 9.86 Providing and fixing bright finished brass night latch including necessary screws etc. complete (best make of approved quality). 290 9.87 Providing and fixing special quality bright finished brass cupboard or wardrobe locks with four levers including necessary screws etc. complete (best make of approved quality) : 9.87.1 40 mm 9.87.2 50 mm 9.87.3 65 mm 9.87.4 75 mm 291 9.88 Providing and fixing 50 mm bright finished brass cup board or wardrobe knob with necessary screws (best make of approved quality) 292 9.89 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 293 9.90 Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete. 294 9.91 Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete : 9.91.1 300 mm weighing not less than 330 gms 9.91.2 250 mm weighing not less than 280 gms 9.91.3 200 mm weighing not less than 240 gms 295 9.92 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete: 9.92.1 150 mm 9.92.2 115 mm 9.92.3 90 mm 296 9.93 Providing and fixing Cromium plated brass hanging type floor door stopper with necessary screws, etc. complete. 297 9.94 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm) with necessary accessories and screws etc. complete. 298 9.95 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. 299 9.96 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 300 9.97 Providing and fixing chromium plated brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 301 9.98 Providing and fixing chromium plated brass night latch including necessary screws etc. complete (Best make of approved quality). 302 9.99 Providing and fixing special quality chromium plated brass cupboard locks with six levers including necessary screws etc. complete (Best make of approved quality) of : 9.99.1 Size 40 mm 9.99.2 Size 50 mm 9.99.3 Size 65 mm 9.99.4 Size 75 mm 303 9.100 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. 304 9.101 Providing and fixing chromium plated brass sliding door bolts ISI marked with nuts and screws etc complete. 9.101.1 300x16mm 9.101.2 250x16mm 305 9.102 Providing and fixing chromium plated brass tower bolts ISI marked with nuts and screws etc complete. 9.102.1 400X10mm 9.102.2 300x10mm 9.102.3 250x10mm 9.102.4 200x10 mm 9.102.5 150x10 mm 9.102.6 100x10 mm 306 9.103 Providing and fixing chromium plated brass door latch ISI marked with necessary screws etc complete. 9.103.1 300x16x5mm 9.103.2 250x16x5mm 307 9.104 Providing and fixing chromium plated brass night latch ISI marked with necessary screws etc complete. 308 9.105 Providing and fixing chromium plated brass handles with necessary screws etc. complete: 9.105.1 125 mm 9.105.2 100 mm 9.105.3 75 mm 309 9.106 Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. 310 9.107 Providing and fixing chromium plated brass casement stays (straight peg type) with necessary screws etc. complete : 9.107.1 300 mm weighing not less than 330 gms 9.107.2 250 mm weighing not less than 280 gms 9.107.3 200 mm weighing not less than 240 gms 311 9.108 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Note:- Aluminum hinges shall not be used in wooden shutters. 9.108.1 125x75x4 mm 9.108.2 125x63x4 mm 9.108.3 100x75x4 mm 9.108.4 100x63x4 mm 9.108.5 100x63x3.2 mm 9.108.6 75x63x4 mm 9.108.7 75x63x3.2 mm 9.108.8 75x45x3.2 mm 312 9.109 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 9.109.1 300x16 mm 9.109.2 250x16 mm 313 9.110 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.110.1 400X10mm 9.110.2 300x10 mm 9.110.3 250x10 mm 9.110.4 200x10 mm 9.110.5 150x10 mm 9.110.6 100x10 mm 314 9.111 Providing and fixing aluminium pull bolt lock anodised ISI marked (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws bolts, nut and washers etc. complete. 315 9.112 Providing and fixing 50cm long aluminium kicking plate 100x3.15 mm anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 316 9.113 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.113.1 125 mm 9.113.2 100 mm 9.113.3 75 mm 317 9.114 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 9.114.1 Single rubber stopper 9.114.2 Twin rubber stopper 318 9.115 Providing and fixing aluminium casement window stays ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 319 9.116 Providing and fixing aluminium tee channels (heavy duty) with rollers, stop end in pelmets as curtain rod. 320 9.117 Providing and fixing aluminum U beading of required size to Pre-laminated /flush door shutter including fixing etc. complete as per direction of Engineer-in-charge. 321 9.118 Providing and fixing PTMT handles with necessary screws etc. complete. 9.118.1 125x34x24 mm weighing not less than 23 gms. 9.118.2 150x34x24 mm weighing not less than 26 gms. 322 9.119 Providing and fixing PTMT Butt hinges with necessary screws etc. complete. 9.119.1 75x60x10 mm fitted with 5.5 mm dia M.S. Bright Bar Rod weighing not less than 34 gms. 9.119.2 100x75x10 mm fitted with 5.5 mm dia MS Bright Bar Rod weighing not less than 53 gms. 323 9.120 Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete. 9.120.1 152x42x18 mm weighing not less than 60 gms. 9.120.2 202x42x18 mm weighing not less than 78 gms. 324 9.121 Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms. 325 9.122 Providing and fixing PTMT hanging type floor door stoper with necessary screws etc complete. 326 9.123 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws: 9.123.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.123.1.1 Second class teak wood. 9.123.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.1.3 Kiln seasoned selected class of sheesham wood. 9.123.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.123.2.1 Second class teak wood. 9.123.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.2.3 Kiln seasoned selected class of sheesham wood. 9.123.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.123.3.1 Second class teak wood. 9.123.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.3.3 Kiln seasoned selected class of sheesham wood. 9.123.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.123.4.1 Second class teak wood. 9.123.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.4.3 Kiln seasoned selected class of sheesham wood. 327 9.124 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 9.124.1 With 2nd class teak wood beading 62x19 mm. 9.124.2 With 12 mm mild steel U beading. 328 9.125 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of Haldu, Kail, Bija wood in scantling of section 50x25mm fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. 329 9.126 Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 50x50mm (base and height). 330 9.127 Providing and fixing 2nd class teak wood lipping/ moulded beading or Taj beading of size 18x5mm fixed with wooden adhesive of approved quality and screws/ nails on the edges of the Pre-laminated particle board as per direction of Engineer- in-charge. 331 9.128 Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminium door with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 332 9.129 Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws etc. complete (Best make of approved quality). 9.129.1 Triple strip vertical type. 9.129.2 Double strip (horizontal type). 333 9.130 Providing and fixing magic eye in door shutters including fixing. Complete (Best make of approved quality). 334 9.131 Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in-charge. 9.131.1 300mm long 9.131.2 450mm long 9.131.3 500mm long 335 9.132 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by P/F stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) 336 9.133 Providing and fixing 12mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick. 9.133.1 Marine plywood conforming to IS: 710 9.133.2 Fire retardant plywood conforming to IS: 5509. 337 9.134 Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. 9.134.1 1.5 mm thick. 9.134.2 1.0 mm thick. 338 9.135 Providing and fixing cup board shutters 25mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked exterior grade (Grade l Type ll) having one side decorative lamination and other side balancing lamination including IInd class teak wood lipping of 25mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of the Engineer-in-Charge. 339 9.136 Providing and fixing cup board shutters with 25mm thick veneered particle board IS : 3097 marked exterior grade (Grade I) of approved make including IInd class teak wood lipping of 25mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of Engineer-in- Charge. 9.136.1 With decorative veneering on one side and commercial veneering on other side. 9.136.2 With non decorative veneering on both sides. 340 9.137 Providing and fixing factory made shutters of 25 mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium U type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of U beading and hinges will be paid for separately). 341 9.138 Providing and fixing in wall lining MDF board medium density fibre board IS: 14587:1998 marked, Pre-laminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. complete. 9.138.1 12 mm thick. 9.138.2 18 mm thick. 9.138.3 25 mm thick. 342 9.139 Providing and fixing 25mm thick pre- laminated medium density fibre board exterior grade(Grade-I) IS:14587:1998 marked one side decorative to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickeled plated bright finishing M.S. piano hinges IS:3818 marked with necessary screwed complete 343 9.140 Providing and fixing skirting with Pre- laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand complete. 9.140.1 18 mm thick 9.140.2 25 mm thick 344 9.141 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corner (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete. 9.141.1 75mm overall thickness partition with 12.5 mm thick double skin fire rated glass reinforced gypsum (GRG) plaster board conforming to IS: 2095: part 3 1996 Board with BIS certification marks. 9.141.2 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS:2095: part I 1996 Board with BIS certification marks. 9.141.3 66mm overall thickness Partition with 8mm thick double skin Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq.cm, Bending Strength 100 kg./sq.cm. 9.141.4 66mm overall thickness partition using 8mm thick double skin non- asbestos multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) as per IS: 14862 with suitable fibre cement screw. 9.141.5 68mm overall thickness partition using 9mm thick Heavy Duty Fibre Cement Board double skin non asbestos, reinforced with cellulose fibre,manufactured through autoclaving proces(High presssure steam cured)Type A, Category 4 conforming to IS 14862:2000. (for wet areas) 9.141.6 70 mm overall thickness Partition using 10mm thick double skin non-asbestost multipurpose termite, fire & moisure resistance (acoustic 30db) cement bonded particle board as per IS: 14276 with suitable cement bonded board screw. 345 9.142 Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the W profile (0.55mm thick ) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55 mm, placed @ 610mm C/C with fully threaded self- tapping dry wall screws. Board is fixed to the W profile with 25 mm countersunk ribbed head screws @ 200mm C/C., all complete as per the drawing and directions of engineer-in-charge the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. 9.142.1 10 mm thick tapered edge calcium silicate board made with calcareous and siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure, with compressive strength 225 kg/sq.cm, Bending strength 100 kg/sq.cm. 9.142.2 12 mm thick Gypsum board conforming to IS: 2095 Part-I. 9.142.3 8 mm thick non-asbestost multipurpose termite, fire & moisure resistance cement bonded particle board as per IS: 14276 with suitable cement bonded board screw. 9.142.4 8mm Both side Factory Prelamianted cement bonded particle board as per IS: 15786. 9.142.5 9mm thick non asbestos,heavy duty fibre cement board reinforced with cellulose fibre manufactured through autoclaving process(High pressure steam cured) Type A,Category 4, conforming to IS 14862. 346 9.143 Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically and horizontally ) including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer- in-charge. 347 9.144 Providing and fixing panelling or paneling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587 348 9.145 Providing and fixing Pre -laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately). 9.145.1 Board 12 mm thick 9.145.2 Board 18 mm thick 349 9.146 Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). 9.146.1 18 mm thick 9.146.2 25 mm thick 350 9.147 Providing and Installation of acoustical wall panelling fabric finish hardened square edge, FR grade fabric (colour as approved by Egnineer in charge) wrapped soft fibre core (glass fibre) panel having metal framing, of size 600x2100x25mm having density 100-120Kgs/ m3, weight 3.0kg/m2 NRC up to 0.9 installed by using impaling clip. Impaling clips are attached directly to the wall/frame work with the points extending outward. Then panels shall positioned and pressed into place. 351 9.148 Providing and installation of acoustical wall panelling wood finish Slats made out of HDF board , Melamine / veneer laminated finish, perforated wooden grooved slats (2mm grooves @ 8mm centers) / (2mm Slats @16mm pitch) / (2mm grooves @ 32mm centers) / (2mm grooves @ 64mm centers), Aluminium core cross channel having thickness 0.5mm, length 2400mm, web 15mm and 27mm, depth 18mm and flanges of 7mm with suitable edge and centre brackets is then fixed perpendicular to the cross channel with the help of fasteners at every 400mm centers. Contractor to Provide expansion joints of 3mm at every 5mts bothways. 352 9.149 Providing and installation of paintble acoustic wall panelling consisting of strand kerfed edge paint finished as approved by Engineer in charge. magnesite bonded wood fiber panels of size 600x2400x20mm having density 400kg/m3, weight 8- 20kg/m2 which is fixed to GI strut system. fastened to wall positioned horizontally in a regular manner at 600mm centers. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channel at 600mm centers. The Kerfed edge panels shall be then inserted into the H-spline against wall to perfect fit. 9.149.1 Wt. 8.20 kg/m2 9.149.2 Wt. 4.2 kg/m2 353 9.150 Providing and fixing plain lining with necessary screws/nuts and bolts/ nails including a coat of approved primer on one face and fixed on wooden /steel frame work complete as per direction of Engineer-incharge. (Frame work shall be paid forseparately) 9.150.1 12mm thick commercial ply conforming to IS: 1328 BWR type. 9.150.2 18mm thick commercial ply conforming to IS: 1328 BWR type. 354 9.151 Providing and Installation of acoustic wall panelling consisting of Soak Coard of selected colours as approved by Engineer in charge. Kerf edge Fabric wrapped wood fiber panels of size 600x2400x20mm having density 400Kgs/m3, weight 4- 20kg/m2 installed by using GI strut system. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channels at 600mm centers. Kerfed edge Fabric wrapped panels shall be then inserted into the H-spline against wall to perfect fit. 355 9.152 Providing and Installation of acoustic wall panelling consisting of Soak Cord of selected colours as approved by Engineer in charge, square edge Fabric wrapped wood fiber panels of size 600x1200x10mm having density 400Kgs/m3, weight 4- 20kg/m2 installed by using GI struts,Z bars. GI Z bars having 40mm height, thickness 1.2mm is first fixed behind the panels by identifying resin spots by using suitable fasteners.Clean exposed surfaces of wall and ensure walls are in plumb line before installing on wall (provide necessary packing shims if required). Soak cord square edge panels shall be slided into the Z bars fixed on wall. 356 9.153 Providing and installation of acoustic wall panelling consisting of Stretch NRC by using FR Grade NRC fabric of size 1700mm width, shall be stretched by using wooden base 10mm thick, rigid vinyl Stretch Tracks half wrap/ full wrap 25mm and Midseam 300mm centers. The fabric is stuck on the Align Tape (by removing the protective cover) at the same time as being stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note -minimum 50mm additional fabric is required for tucking hence maximum module width would be 1600mm. 357 9.154 Providing and Installation of wall panelling consisting of Square edge Magnesia core panels of size 1100x2400x8mmmm having density 1000kgs/m3, weight 8kg/m2 installed by using GI Strut system. The GI struct system includes Cross channel having thickness 0.45mm, length 3600mm, knurled web 40, depth 10mm and equal flanges of 15mm is fastened to wall positioned horizontally in a regular manner at 600mm c/c. The panels to be fixed on the cross channel with suitable fasteners. 358 9.155 Supplying and installation of magnesia block 66 mm thick drywall partition including Framework includes Floor/ Head GI channels having thickness 0.5mm, length 3600mm, equal flanges of 32mm and web of 50mm fixed to floor and ceiling with suitable fasteners at 300mm centers staggered. Second layer of magenesia oxide block 8mm thick should be fixed other side of the frame work similar fashion as the first layer. 3mm gap should be maintained between boards.3 mm gap shall be filled with jointing compound. Magnesia oxide block shall have following physical charecterstics. 9.155.1 Using 8mm thick magnesia block 9.155.2 Using10mm thick magnesia block 9.155.3 Using12mm thick magnesia block 9.155.4 Using12mm thick magnesia block 359 9.156 Add extra for providing and fixing Thermal insulation by providing 50mm thick synth PF having dencity 1000 GSM within the cavity held in position by using chicken wire mesh/ cross bracing/ pasting to the wall. 360 9.157 Providing and laying Gypsum panel partitions 100mm thick with water proof Gypsum panels of size 666x500x100mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturers specifications in superstructure above plinth level up to floor II level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2. 361 9.158 Providing and fixing factory made UPVC door frame made of UPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frame reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge: 9.158.1 Extruded section Profile size 48x40 mm. 9.158.2 Extruded section Profile size 42x50 mm. 362 9.159 Providing and fixing Panelled UPVC door shutter to existing door frames. 24 mm thick factory made UPVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturers specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). 363 9.160 Providing and fixing UPVC panelled door shutter UPVC 30 mm thick factory made PVC or UPVC door shutter made of styles and rails of a UPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturers specification and direction of Engineer-in-charge. 364 9.161 Providing and fixing 25mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mmx25mm or less as per requirement with an average wall thickness of 1mm (± 0.3mm). PVC foam end cap of size 23x10mm are provided on both vertical edges to ensure the overall thickness of 25mm. The Top and Bottom edges of the shutter are covered with an end-cap of the size 25mmx11mm. Door shutter shall be reinforced with special polymeric reinforcements as per required specification and direction of Engineer-in- charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. 365 9.162 Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100mmx37mm with wall thickness 2mm (±0.2mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos. of plastic brackets of size 100mmx37mm, wall thickness 2mm (+0.2mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100mmx20 mm, and inserting 2 nos. tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturers specification and direction of Engineer-in-charge. 366 9.163 Providing and Fixing, factory made, PVC door frame made of PVC extruded sections of size 75mmx53 mm, having wall thickness 2.0mm (±0.2mm). Both verticals sides of the frame reinforced with PVC profile of cross section size 28mm x 30mm x2mm thickness (± 0.2 mm) and 75mmx200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut jointed and fusion welded together, including providing and fixing 3 nos. of 125mm long stainless steel hinges to frame, fixing the frame with jamb with required nos. and sizes of anchor dash fastener, all complete as per manufacturers specification and direction of engineer-in-charge. 367 9.164 Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115mm x 37mm with wall thickness , panels of 100 x 20 mm printed and laminated and inserting 2 nos. 6 mm dia. bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturers specification and direction of Engineer-in-Charge. 368 9.165 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size, complete as per manufacturers specification and direction of Engineer-in- Charge. 369 9.166 Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top and bottom rails. M.S. frame shall have a coat of steel primers and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification and drawing. 9.166.1 Plain PVC door shutters. 9.166.2 Pre laminated PVC door shutters. 370 9.167 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width and 32 mm thickness, frame will be mitred and Jointed with self driven self tapping screws of size 38 mm x 4 mm and PVC solvent cement, including fixing the frame to wall with suitable dia and length anchor fastener as per manufacturer’s specification and direction of Engineer-in-charge. 371 9.168 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles and rails shall be of size 75 mmx30 mm having wall thickness 5 mm. The styles, top and bottom rails shall have one side wall thickness of 15 mm integrally extruded in the middle of the lock rail and fixed with styles with the help of PVC solvent cement and self driven self tapping screws of size 100 mmx8 mm complete as per manufacturers specifications and direction of Engineer-in-charge: 9.168.1 Non decorative finish. 9.168.2 Decorative finish (both side wood grained finish). 372 9.169 Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately) 9.169.1 Single rebate (75 mm X 50 mm) 9.169.2 Single rebate (100 mm X50 mm) 9.169.3 Single or double rebate (125 mm X 65 mm) 373 9.170 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.2 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.3 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.4 35 mm thick WPC (Wood polymer composite) solid plain flush door shutter 374 9.171 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 9.171.1 30 mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter 9.171.2 35 mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter 375 9.172 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white colour and other side of board laminated with PVC foil of minimum 14 micron thickness of approved design pasted with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 9.172.1 18 mm thick 9.172.2 25 mm thick 376 9.173 Providing and fixing factory made single extruded WPC (Wood polymer composite solid plain white color board for backing of cupboards and bathrooms/ kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-in-Charge. (Note: stainless steel screws shall be paid separately) 9.173.1 6 mm thick 9.173.2 12 mm thick 377 9.174 Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali CNC (Computer numeric control) routed of approved design by Engineer-in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. 378 9.175 Providing and fixing PVC Door Frame of size 50x47mm with a wall thickness of 5 mm (±0.2 mm) made out of single piece extruded PVC profile, with mitred cut joints and joint with 2nos of PVC bracket of size 40x20mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100mm long anchor fasteners complete, all as per manufacturer’s specification and direction of Engineer -in- charge. 379 9.176 35 mm thick factory made Solid panel PVC Door shutter made out of single piece extruded soild PVC profiles, 5mm (±0.2mm) thick, having styles and rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm solid core in middle of rail section integrally extruded, fixing the styles and rails with the help of solvent and self driven self tapping screws of 125 mm x11 mm, including providing 5mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturers specification and direction of Engineer-in- charge. 9.176.1 Non decorative finish (matt finish). 9.176.2 Decorative finish (wood grained finish). 380 9.177 Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive. 381 9.178 Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat .Doorframe laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibreglass from all sides. MS stat shall be provided 382 9.179 Providing and fixing to existing door frames. 30 mm thick glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS: 14856 including fixing to frames. 383 9.180 Providing and fixing door frame FRP 30mm thick fiberglass reinforced Plastic (F.R.P.) flush door shutter in different plain and wood inish made with fire retardant grade unsaturated polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 384 9.181 Providing and fixing factory made Fibreglass Reinforced plastics (F.R.P.) chajja 4mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746 duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather and sunlight. 385 9.182 Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in- charge (Dash fastener to be paid for separately). 386 9.183 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II) tested and certified as per laboratory approved by Engineer-in-charge with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100mm wide, bottom rail 200mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). 387 9.184 Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc. complete all as per direction of Engineer- in-charge. With clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistance. 388 9.185 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch and Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. 389 9.186 Providing and Fixing factory made UPVC door frame made of UPVC exturded sections, of size 65 mmx55 mm with wall thickness 2.0 mm (±0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mmx30 mm having wall thickness 2 mm (±0.2mm), including providing and fixing 3 nos. of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number and size of anchor dash fastners, all complete as per manufacturers specification and direction of Engineer-in-charge. 390 9.187 Providing and Fixing, UPVC factory made, white colour casement/sliding window and door made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ± 0.2mm thick galvanised steel profile to be inserted in required profile, frame will be fixed to the wall with 8 mmx100 mm long fasteners, all complete as per direction of Engineer-in-charge. (Glazing, hardware hinges and fitting etc. to be paid separately.) 9.187.1 Casement Window (Outward/Inward opening) with hinge System. 9.187.1.1 Frame (50 mm x 50mm) 9.187.1.2 Sash (Style and Rail) (62 mm x 34 mm) 9.187.1.3 Mullion (intermediate Section) (66mm x 50 mm) 9.187.1.4 ‘T Profile (one vertical length in between two shutters) (24mm x 34.5mm) 9.187.1.5 Glazing bead (12mm x 18mm) 9.187.2 Casement Window (With friction hinge and outward opening) 9.187.2.1 Casement Frame (67mm x 62mm) 9.187.2.2 Casement Window Sash/Mullion (67mm x75mm) (style, rail and intermediate section) 9.187.2.3 Casement Glazing bead (35mm x 18 mm) 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67mm x 52mm) 9.187.3.2 Sliding window Sash (60mm x 44mm) 9.187.3.3 Sliding Interlock for Window (one vertical length in each shutter)(45.5 mm x 28 mm) 9.187.3.4 Sliding Glazing bead (35 mm x 18 mm) 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67mm x 52mm) 9.187.4.2 Sliding Door Sash (80mm x 44mm) 9.187.4.3 Sliding Interlock for Door (one vertical length in each shutter) (45.5 mm x 28 mm) 9.187.4.4 Sliding Glazing bead (35 mm x 18 mm) 391 9.188 Providing and fixing stainless steel (SS- 304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality with necessary stainless steel screws etc. as per direction of Engineer-in-charge. 9.188.1 200 x 19 x 1.9 mm 9.188.2 250 x 19 x 1.9 mm 9.188.3 300 x 19 x 1.9 mm 9.188.4 350 x 19 x 1.9 mm 9.188.5 400 x 19 x 1.9 mm 392 9.189 Providing and fixing casement handle made of zinc alloyed (white powder coated) for UPVC casement window with necessary screws etc. complete. 393 9.190 Providing and fixing zinc alloyed (white powder coated) touch lock for UPVC sliding window with necessary screws etc. complete. 394 9.191 Providing and fixing steel roller for UPVC sliding window with necessary screws etc. complete. 395 9.192 Providing and fixing steel roller for UPVC sliding door with necessary screws etc. complete. 396 9.193 Providing and fixing steel (white powder coated) crescent lock for UPVC sliding window/ door with necessary screws etc. complete. 397 9.194 Providing and fixing factory made UPVC white colour casement/casement cum fixed glazed windows comprising of UPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For UPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.194.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) 9.194.2 Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). 9.194.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). 9.194.4 Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) 9.194.5 Casement window duble panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm.) 9.194.6 Casement cum fixed panel window having both and single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm & mullion 67 x 80 all having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm. Upto 5.00 sqm.) 398 9.195 Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic capsof approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.195.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) 399 9.196 Providing and fixing made UPVC white colour casement/ casement cum fixed glazed door comprising of UPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer- in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.196.1 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). 9.196.2 Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm). 400 9.197 Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) 9.197.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 9.197.3 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm). 9.197.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). 9.197.5 Three track three panels sliding window made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) 401 9.198 Providing and fixing factory made UPVC white colour sliding glazed window above 1.50 m in height dimension comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.198.1 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm). 9.198.2 Two track four panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). 402 9.199 Providing and fixing factory made UPVC white colour sliding glazed door comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section madAfter fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer- in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Note: - For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.199.1 Two track two panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 10.00 sqm). 9.199.2 Two track four panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 8.00 sqm upto10.00 sqm). 9.199.3 Three track three panels sliding door made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) 9.199.4 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) 403 9.200 Providing and fixing 30mm thick factory made solid panel prelaminated PVC internal door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for styles top, lock and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture PVC beading as gap insert below top and bottom rail joined together using solvent cement adhesive. An additional 5mm thick Prelaminated PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ channel using PVC solvent cement adhesive etc. complete as per direction of Engineer-in- charge. Manufacturer’s specification and drawing. 30 mm thick pre laminated PVC door shutters. 404 9.201 Providing and fixing factory made integral PVC flush door shutter made from rigid PVC foam sheet (Single Extruded) with density not less than 600 kg/cum, conforming to IS: 2380 part 14 for screw holding strength with Celluka finish surfaces on both sides at the manufacturing process itself, manufactured by an ISO : 9001 -2000 certified company. 9.201.1 24 to 25 mm thick plain solid PVC flush door shutter 9.201.2 28 to 30 mm thick plain solid PVC flush door shutter 405 9.202 Providing and fixing factory made pre laminated solid PVC flush door shutters 28 to 30 mm thick made from co-extruded three layer rigid PVC foam sheet with density not less than 600 kg/cum, conforming to IS: 2380 part 14, for screw holding strength and outer layers laminated on both sides by laminated sheet with density not less than 1400 kg/cum, lamination shall be at the manufacturing process itself and manufactured by an ISO: 9001-2000 certified company. 9.202.1 1mm thick laminated sheet 9.202.2 0.12 mm thick laminated sheet 406 9.203 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) laminated type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens with well matched 3mm thick commercial 3ply veneering consisting of vertical grains, cross bands withing frame of door/cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS: 2202. The rate shall be inclusive of all material and labour complete and as per specification and dirction of Engineer-in-Charge. 9.203.1 35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.203.2 35mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.203.3 25mm thick (for cupboard) including 3 nos. 75mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 407 9.204 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) non decorative type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens (strips) and frame of kiln seasoned and chemically treated, finger jointed cross bands including all material and labour complete as per specification and direction of engineer-in- charge. Spacing of finger joints in wood as above shall not be less than 50cm. Each shutter shall be factory made to the exact opening size within frame of doors/cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and confirmity with IS:2202. 9.204.1 35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary. 9.204.2 30mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.204.3 25mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 408 9.205 Deduct for not providing 2nd class teak wood batten lipping in factory made shutters i.e. item no 9.203 and 9.204. 409 9.206 Providing & fixing acrylic solid surface in thickness 4/6/12 mm of approved colour made out of non-porous surfacing material homogeneously composed of ± 1/3 acrylic resin (also known as PolyMethyl Methacrylate -PMMA), and ± 2/3 NO extra shall be paid for joint adhesive, silicon or related accessories and for transportation. Item should cover 5 years, commercial warranty of product as per FCWS norms. The product should be UV protected for exterior applications & LGA hyginene tested anti bacterial for health care application areas. Area of application are Table Tops, Exterior facade cladding, health care areas like modular operation theater hospital scrubs, wash basins, partition & paneling, laboratory commercial show room, hotels, office & residential areas. 9.206.1 Acrylic Solid Surface sheet – Glacier white designer white 9.206.1.1 6 mm thick sheet 9.206.1.2 12 mm thick sheet 9.206.2 Acrylic Solid Surface sheet - Any Solid colours/Hospital use Medi Blue 9.206.2.1 6 mm thick sheet 9.206.2.2 12 mm thick sheet 9.206.3 Acrylic Solid Surface sheet - Any other 9.206.3.1 6 mm thick sheet 9.206.3.2 12 mm thick sheet 410 9.207 Providing and fixing of 8 mm thick non asbestos multipurpose board reinforced with cellulose fibers for wall cladding will consist of following operations:1. Fixing of a layer of 6mm Moisture/fire Resistance Heavy Duty fibre cement Boards over above mentioned 6 mm heavy duty fibre cement board with the help of 25mm self drilling, self tapping Fibre Cement screws @ 300mm c/c. All external corners are to be protected with the use of suitable corner profile of GI or PVC. All above operation is to be done in order and as directed by Engineer-in-Charge.(frame work to be paid separately). 411 9.208 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS: 15380(2003), eco-friendly, termite resistant, borer free, anti warping phenol formaldehyde (PF), decorative designe moulded or rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company’ gujcon, century, green shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.208.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.208.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.208.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. piano hinges with screws. 412 9.209 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), non decorative designe moulded and labor complete as per specifications and direction of engineer-in- charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.209.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.209.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws 9.209.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. piano hinges with screws. 413 9.210 Providing and fixing IS marked factory made High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), 2 and 4 Panel designe moulded or plain construction with particle board shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.210.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.210.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 414 9.211 HDF decorative prelaminated pine wood panel door with glass / wiremash:- Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), The rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.211.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.211.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 415 9.212 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), . The rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.212.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.212.2 32 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.212.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. Piano hinges with screws. 416 9.213 Non Decorative Pine Wood Flush Door:- Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) non decorative type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and chemically treated, finger jointed all material and labour complete as per specification and direction of engineer- in-charge. Spacing of finger joints in wood as above shall not be less than 50 cm. Each shutter shall be factory made to the exact opening size within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202 9.213.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.213.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.213.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 417 9.214 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) laminated type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and frame of kiln seasoned sheet shall be as per IS: 2046 type S of approved quality. Each shutter shall be factory made to the exact size (opening) within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. The rate shall be inclusive of all material and labour complete and as per specification and direction of engineer-in- charge. 9.214.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.214.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.214.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 418 9.215 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) laminated type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and frame of kiln seasoned within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. The rate shall be inclusive of all material and labour complete and as per specification and direction of engineer-in-charge. 9.215.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.215.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.215.3 25mm thick (for cupboard) including 3 nos. 75 mm long ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 419 9.216 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) veneer decorative type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) s and commercial grade face veneers on both outer faces of shutters including kiln seasoned and chemically treated, finger jointed all material and labour complete as per specification and direction of engineer-in- charge. Spacing of finger joints in wood as above shall not be less than 50 cm. Each shutter shall be factory made to the exact opening size within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. 9.216.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.216.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.216.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 420 9.217 Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides,made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastne with necesary stainless steel screws, all complete as per direction of Engineer-in-charge. 421 9.218 Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity.Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. 422 10.1 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 423 10.2 Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 424 10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. Rate includes recess cutting in floor and making good the same wherever required. 425 10.4 Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron, 3mm M.S.gusset plates at the junction and corners 25mm dia pulley,40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer. 426 10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angels 40x40x6mm for diagonal braces 10.5.2 Using flats 30x6mm for diagonal braces and central cross piece. 427 10.6 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to I.S. 4454- part-1 and M.S. top cover of required thickness for rolling shutters. 10.6.1 80x1.25mm M.S. laths with 1.25 mm thick top cover. 10.6.2 80x1.20 mm M.S. laths with 1.20 mm thick top cover. 10.6.3 80x0.90 mm M.S. laths with 0.90 mm thick top cover. 428 10.7 Extra for providing suitable mechanical device chain and crank operation for operating rolling shutters. 10.7.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 10.7.2 Exceeding 16.80 sqm in area. 429 10.8 Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-Charge. (Area of grill to be measured). 430 10.9 Providing and fixing ball bearing for rolling shutters. 431 10.10 Providing and fixing factory made ISI marked glazed steel doors, windows and ventilators side /top /centre hung with beading and Z-section all members such as F7D, F4B, K11 B and K12 B and other tubular section member etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design (sectional weight of only steel members shall be measured for payment). 10.10.1 Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size). 10.10.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.10.3 Extra for providing and fixing steel beading of size 10x10x1.6mm (box type) approved shape and section with screws instead of glazing clips and metal sash putty in steel doors, windows, ventilators and composite units. 432 10.11 Providing and fixing L-iron or T-iron frames for doors, windows and ventilators of mild steel L-section or T-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 10.11.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 433 10.12 Providing and fixing pressed steel door frames made of 1.6 mm thick steel profile conforming to IS: 4351 manufactured from commercial mild steel sheet including hinges, jamb, lock jamb, M.S. pressed butt hinges, with mortar guards, lock strike-plate and shock absorbers as specified filling the frame with Cement Concrete 1:3:6 at site before fixing (cost of concrete to be paid separately) fixing with adjustable lugs (200 mm long & 1.0 mm thick) and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in- charge: 10.12.1 Profile B of 1.60mm thick single rebate of size 80mmx50mm 10.12.1.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.1.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.2 Profile C of 1.60mm thick single rebate of size 100mmx50mm 10.12.2.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.2.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.3 Profile E of 1.60mm thick double rebate of size 115mmx50mm 10.12.3.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.4 Profile B of 1.25mm thick single rebate of size 80mmx50mm 10.12.4.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.4.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.5 Profile C of 1.25mm thick single rebate of size 100mmx50mm 10.12.5.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.5.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.6 Profile E of 1.25mm thick double rebate of size 115mmx50mm 10.12.6.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.6.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 434 10.13 Providing and fixing M.S. Tubular frames and shutters or frames only or shutters only for doors, windows, ventilators and cupboard with any sections, made of 1.60 mm or 1.25 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size as per drawing, including fixing of necessary butt hinges, stays and screws and applying a priming coat of approved steel primer excluding cost of all fittings such as handles, tower bolts, sliding door bolts, latches etc. and panels. 10.13.1 Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size). 10.13.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 435 10.14 Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.14.1 Hot finished welded type tubes 10.14.2 Hot finished seamless type tubes 10.14.3 Electric resistance or induction butt welded tubes. 436 10.15 Design, supply, fabrication, taransportion and erection of structural steel/mild steel built-up sections for steel building in column, rafter, truss, floor joist, wind bracings, tie beam, foundation bolts, fasteners etc. Including two coats of Epoxy paint and one coat of primer. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code. 437 10.16 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. 438 10.17 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 16mm dia M.S. bar bent to shape as per standard drawing. 439 10.18 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. 440 10.19 Providing and fixing bolts including nuts and washers complete. 441 10.20 Providing and fixing M.S. rivets of sizes in position. 442 10.21 Welding by gas or electric plant including transportation of plant at site etc. complete. 443 10.22 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.22.1 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 444 10.23 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying a priming coat of approved steel primer. 10.23.1 M.S. tube. 10.23.2 E.R.W. tubes. 445 10.24 Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer-in-charge. 10.24.1 10x60 mm 10.24.2 10x80 mm 10.24.3 10x120 mm 10.24.4 10x140 mm 10.24.5 10x160mm 446 10.25 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 447 10.26 Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3mm and nuts and bolts complete. 10.26.1 Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4 mm aperture on both sides 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. 448 10.27 Providing and fixing glass panes/ steel sheet/ fibre sheet with putty and glazing clips in steel doors, windows, clerestory windows all complete. 10.27.1 With 4.0 mm thick glass panes 10.27.2 With 5.50 mm thick glass panes 10.27.3 With 1mm thick mild steel sheet i/c 10x10x1.6mm box beading. 10.27.4 With 2mm thick fibre reinforced polymer (FRP) sheet i/c 10x10x1.6mm box beading. 10.27.5 With 1mm thick Galvanised steel sheet i/c 10x10x1.6mm box beading. 10.27.6 With 4mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 10.27.7 With 6mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 10.27.8 With 8mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 449 10.28 Add extra for providing and fixing froasted glass instead of float glass. 10.28.1 With 4.0 mm thick glass panes. 10.28.2 With 5.5 mm thick glass panes. 450 10.29 Supplying at site: 10.29.1 R.C.C. Standards post/ struts/rails/ poles of mix 1:1.5:3 (1 cement : 1.5 sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in-charge including fixing (cost of earth works in excavation, concrete works in foundation to be paid separately). 10.29.2 Angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (cost of earth work in excavation and concrete work in foundation to be paid separately) 10.29.3 Supplying at site -Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming painting to be paid for separately). 451 10.30 Supplying and fixing turn buckles and straining bolts for barbed wire fencing. (Labour rate only). 452 10.31 Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) with GI barbed wire. 453 10.32 Fencing with barbed G.I. wire angle iron post placed fitted to at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used. 454 10.33 Fixing Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I. staples on wooden plugs or tied to 6 mm bar nibs with G.I. binding wire (cost of posts, painting, earth work in excavation and cement concrete to be paid for separately). (Labour rate only). 455 10.34 Providing and fixing G.I. or PVC coated G.I.wire chain link fabric fencing of required width and mesh size including strengthening with 2mm dia wire or nuts, bolts and washers as required complete with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer- in-charge. (Cost of post, painting earthwork & c.c. to be paid separately) 10.34.1 Made of G.I. wire. 10.34.2 Made of G.I. wire, PVC coated to achieve outer dia. not less than 5mm in required colour and shade. 456 10.35 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia. 3mm including strengthening with 2mm dia. wire or nuts, bolts and washers as required complete, with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand : 10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer-in- Charge. (cost of post painting earth work & C.C. to be paid separately) 457 10.36 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately). 458 10.37 Providing and fixing of ISI marked insulated fire rated GI Sheet doors conforming to FD 120-PI classification of IS 3614:2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The factory manufactured door frame and shutter assembly shall be made out of minimum 120 GSM coating as per IS: 277. Door and frame should be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test. All accessories like hardware, vision panel, fire & smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry a label confirming to type of door & its fire rating. The Door frame shall be single rebate grooved profile of size minimum 125 mm x 75mm made out of 1.50mm minimum thick galvanized steel sheet. Frames shall be butt / mitered joint and field assembled with bolting system. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip of size 10x4mm. All provisions should be mortised & provided with necessary inbuilt reinforcement to receive appropriate hardware. Frames should be provided with back plate bracket for anchor fastner with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves (Payable in extra item) for installation of frame in finished plastered masonary wall opening. Note:- For grouting of Steel frames in masonary installations ;cement slurry of 1:3 ratio by civil contractor/fire rated PU foam or such fire rated material may be recommended except head member(Payable in extra item). Door leaf should be minimum 60mm thick fully flush double skin door. Door leaf must be manufactured from minimum 1.2mm thick galvanised steel sheet. The infill material shall be mineral wool of minimum density 96 kg/cum. All doors shall befactory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges of size 100x 89x3 mm along with all suitable hardware (Payable in extra item).Vision lite size 185x285 (max area up to 0.06sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 : 2021 vide clause no. 7.2.7 table no. 2 with a clip on arrangement. The glass will be provided with fire rated ceramic tape of min. 2 mm thickness with min. 15mm width al around on either face. Every Glass pane must carry a permanent marking of its glass manufacturer 459 10.38 Providing and fixing of factory make air tight casement windows made of roll formed galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 10.38.1 Openable window 10.38.2 Fixed windows 460 10.39 Providing and fixing of factory make single rebate openable/fixed windows made of roll formed galvanized pre- pained steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick) heavy duty pivot hinges per shutter and window fitted without glazing including 10mm square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete. 10.39.1 Openable single rebate window 10.39.2 Fixed single rebate window 461 10.40 Providing and fixing of factory make double rebate windows made of roll formed galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, fitted using EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing windows in the concrete/masonry wall by means of self- expanding screws, including 10mm Square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete.. 10.40.1 Openable double rebate window 10.40.2 Fixed double rebate window 462 10.41 Providing and fixing of factory make fixed louvers fabricated from roll formed sections made of galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, colour coated/powder coated Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete. (glazing shall be paid separately as per SOR rate) 463 10.42 Providing and fixing of factory make pre painted steel sliding window 2 track-2 panel sliding window fabricated from roll formed sections made of galvanized steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns The above frames should be fixed to the concrete/masonry walls by means of self-expanding screws. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 464 10.43 Providing and fixing pre painted steel sliding window 3 fabricated from Roll formed sections made of galvanized Steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns The above frames should be fixed to the concrete/masonry walls by means of self-expanding screws. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 465 11.1 40 mm thick Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate) 20mm nominal size stone aggregate in panels finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.(Area of panel not to exceed 2.0 sqm) 466 11.2 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 467 11.3 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 468 11.4 Cement plaster skirting 18 mm thick (upto 30 cm height) with cement mortar 1:3 (1 cement: 3 sand) finished with a floating coat of neat cement. 469 11.5 Cement concrete pavement with Cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) including finishing complete. 470 11.6 Making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. 471 11.7 40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 6mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 1mm to 4mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume including cement slurry etc. complete : (Area of panel not to exceed 2.0 sqm) 11.7.1 Dark shade pigment with ordinary cement. 11.7.2 Light shade pigment with white cement. 11.7.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.7.4 White cement without any pigment. 11.7.5 Light shade pigment with ordinary cement. 11.7.6 Ordinary cement without any pigment. 472 11.8 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 31mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 9mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 4mm to 7mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder : 7 marble chips) by volume including cement slurry etc. complete. (Area of panel not to exceed 2.0 sqm) 11.8.1 Dark shade pigment with Ordinary cement. 11.8.2 Light shade pigment with white cement. 11.8.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.8.4 White cement without any pigment. 11.8.5 Light shade pigment with ordinary cement. 11.8.6 Ordinary cement without any pigment. 473 11.9 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 28 mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 12mm thick with white, black, chocolate, grey yellow or green marble chips of sizes from 7mm to 10mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix : 3 marble chips) by volume including cement slurry etc. complete : (Area of panel not to exceed 2.0 sqm) 11.9.1 Dark shade pigment with ordinary cement. 11.9.2 Light shade pigment with white cement. 11.9.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.9.4 White cement without any pigment. 11.9.5 Light shade pigment with ordinary cement. 11.9.6 Ordinary cement without any pigment. 474 11.10 Marble chips skirting (upto 30 cm height) 18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 sand) : rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix :7 marble chips) by volume : 11.10.1 Dark shade pigment with ordinary cement. 11.10.2 Light shade pigment with white cement. 11.10.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.10.4 White cement without any pigment. 11.10.5 Light shade pigment with ordinary cement. 11.10.6 Ordinary cement without any pigment. 475 11.11 Extra for laying terrazo flooring on staircase treads not exceeding 30 cm in width including cost of forming, nosing etc. 476 11.12 Providing and fixing glass strips 40 mm wide and 4 mm thick in joints of terrazo/ cement concrete floors. 477 11.13 18 mm thick crazy marble stone white, black or as specified marble stone flooring, including filling the gaps with light shade pigment with white cement marble powder mixture (3 parts of white cement : 1 part of marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 white, black or white and black marble chips of sizes from 1mm to 4mm nominal size by volume), with under layer 25mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5 mm nominal size), including rubbing, polishing and cement slurry etc.complete . 478 11.14 Precast terrazo tiles 22mm thick with graded marble chips of size upto12mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) : 11.14.1 Light shade using white cement. 11.14.2 Medium shade using 50%white cement and 50% ordinary cement. 11.14.3 Dark shade using ordinary cement. 11.14.4 Ordinary cement without any pigment. 479 11.15 Extra if terrazo tiles are laid in treads of steps not exceeding 30 cm in width. 480 11.16 Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1:3 (1 cement : 3 sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : 11.16.1 Light shade pigment using white cement. 11.16.2 Medium shades pigment using 50% white cement and 50% ordinary cement. 11.16.3 Dark shade pigment using ordinary cement. 11.16.4 Ordinary cement without any pigment. 481 11.17 Chequeredterrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) : 11.17.1 Light shade pigment using white cement. 11.17.2 Medium shade pigment using 50% white cement, 50% ordinary cement. 11.17.3 Dark shade pigment using ordinary cement. 11.17.4 Ordinary cement without any pigment. 482 11.18 Chequered precast cement concrete tiles any finish, any size 22 mm thick IS:13810-1993 ISI mark in footpath and courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles, 15mm thick screed bad in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. 11.18.1 Light shade pigment using white cement. 11.18.2 Medium shade pigment using 50% white cement 50% Grey cement. 11.18.3 Dark shade pigment using ordinary cement. 11.18.4 Ordinary cement without any pigment. 483 11.19 Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 sandand grey cement slurry, joints treated with white cement mixed with pigment to match colour of stone including rubbing and polishing complete with : (area of slabs over 0.5 sqm) 11.19.1 Makrana white second quality. 11.19.2 Raj Nagar plain. 11.19.3 Agaria White/Morgarh 11.19.4 Katni marble 11.19.5 Black Zebra. 11.19.6 Udaipur / Baroda green marble 11.19.7 Pink plain marble. 11.19.8 Jaisalmer Yellow 484 11.20 Marble stone 18 mm thick in riser of step, skirting, dado and pillar laid on 12 mm average thick cement mortar 1:3 (1 cement: 3 sand and laid with white cement slurry) joints treated with white cement mixed with pigment to match the shade of the slab i/c rubbing and polishing complete. (area of slab over0.50sqm.) 11.20.1 Makrana white second quality. 11.20.2 Raj Nagar plain. 11.20.3 Agaria White/Morgarh 11.20.4 Katni marble 11.20.5 Black Zebra. 11.20.6 Udaipur / Baroda green marble 11.20.7 Pink plain marble. 11.20.8 Jaisalmer Yellow 485 11.21 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement: 3 sand), including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). (Area of slabs over 0.50 sqm.) 11.21.1 Makrana white second quality. 11.21.2 Raj Nagar plain. 11.21.3 Agaria White/Morgarh 11.21.4 Katni marble 11.21.5 Black Zebra. 11.21.6 Udaipur / Baroda green marble 11.21.7 Pink plain marble. 11.21.8 Jaisalmer Yellow 486 11.22 Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish wherever required etc. complete at all levels. Samples approved by Engineer-in- Charge. 11.22.1 Raj Nagar plain/White Marble/Udaipur Green Marble /Zebra black 11.22.2.1 Granite fine grained dark crystal of other colours and various patterns 11.22.2.2 Granite coarse grained light black/ light red/white with crystal of other colours and various patterns 11.22.2.3 Granite grey/pink/brown with various patterns 11.22.3 Cuddpah stone 487 11.23 Extra for prefinished nosing to treads of steps of marble stone. 488 11.24 Extra for marble stone flooring in treads of steps and risers using single length upto 2.00 metre. 489 11.25 Extra for prefinished grooves to treads of steps of granite stone 490 11.26 Providing and laying machine cut, mirror polished, Italian Marble stone (18 mm thick Italian Marble stone slab, Perlato, Rosso erona, Fire Red or Dark Emperadore etc.)work in flooring laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry mixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 491 11.27 Providing and fixing machine cut, mirror / eggshell polished , Marble stone work 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. for wall lining (veneer work) including dado, skirting, risers of steps etc. thick cement mortar 1:3 (1 cement : 3 sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 492 11.28 Italian marble flooring in required design and patterns 11.28.1 Providing and laying machine cut, mirror polished Italian Marble stone 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadoreetc flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Note – This item shall be executed only after the prior approval of Chief Engineer. 493 11.29 Granite work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement: 3 sand) including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately). 111.29.1 Area of slab over 0.50 sqm 11.29.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.1.3 Gray/Pink/Brown or equivalent with various patterns 11.29.2 Area of slab upto 0.50 sqm 11.29.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.2.2 Coarse grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.2.3 Gray/Pink/Brown or equivalent with various patterns 494 11.30 Providing and laying gang saw cut 18 mm thick, mirror polished premoulded (wherever required) and pre polished machine cut granite stonework in flooring of required size shape of approved shade, color and texture in flooring laid over 20 mm thick base of cement mortar 1:4 (1 Cement: 4 sand) including grouting the joints with white cement mixed with matching pigments epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.1.3 Gray/Pink/Brown or equivalent with various patterns 11.90.2 Area of slab upto 0.50 sqm 11.30.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.2.2 Coarsegrained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.2.3 Gray/Pink/Brown or equivalent with various patterns 492 11.31 Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement: 4 sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. (area of slab more than 0.50 sqm) 11.31.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.31.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.31.3 Gray/Pink/Brown or equivalent with various patterns 495 11.32 Deduct for not polishing granite flooring (item no 11.29 & 11.30) 496 11.33 Providing and laying Granite stone flooring in required design and patterns in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing and as directed by the Engineer-in-Charge Granite stone slab Dark Black. Dark Red, White or equivalent, 11.33.1 Flamed Finish Polish 11.33.2 Leather Finish Polish 497 11.34 Granite stone work 18mm thick of any colour in riser of steps, skirting, dado and pillars laid on 12 mm average thick cement mortar 1:3 (1 cement:3 sand) and jointed with white cement slurry mixed with pigment to match the shade of slab. 498 11.35 Providing and fixing 10x10x7.50 cm Granite stone block hand cut andchisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1cement:4 sand) with joints 10mm wide filled with same mortar mixed with matching pigment including ruled pointing etc. complete as per direction of engineer-in charge. 499 11.36 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 sand) 25 mm thick.(Area of slab to be over 0.25 sqm) 500 11.37 Deduction for using 20 mm thick slab instead of 25 mm thick slab of kota stone in item no 11.35 501 11.38 Kota stone slabs in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 502 11.38.1 10-12 mm thick 11.38.2 20 mm thick 503 11.39 Kota stone slab (area less than 0.5 sqm) rough chiseled dressed average 40 mm thick flooring for parking and open area of thickness over 20 mm (average) thick base laid over and jointed with grey cement slurry complete with base of cement mortar 1:4 (1 Cement : 4 Sand) 504 11.40 Providing edge moulding to 18mm thick marble stone counters, Vanities, window sills etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 11.40.1 Marble work 11.40.2 Granite work. 505 11.41 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 506 11.42 Extra for providing opening of required size and shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 507 11.43 Mirror polishing on marble work/Granite work/stone work wherever required to give high gloss finish complete. 508 11.44 Fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1cement : 5 sand) with joints finished flush. 11.44.1 Red sand stone 11.44.2 White sand stone 11.44.3 Grey lime stone 11.44.4 Kota stone 509 11.45 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1 cement : 2 sand) with an admixture of pigment to match the shade of stone. 11.45.1 Red sand stone 11.45.2 White sand stone 510 11.46 40 mm thick machine rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement :5 sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1 cement : 2 sand) mixed with pigment to match the shade of stone and pointing with same mortar 11.46.1 Red sand stone 11.46.2 White sand stone 511 11.47 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 512 11.48 Extra for Kota stone/ sand stone in treads of steps and risers using single length upto 1.05 metre. 513 11.49 Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. 514 11.50 Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete. 515 11.51 Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (having thickness 9 to 10mm) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. 516 11.52 Providing and laying rectified Glazed Ceramic wall tiles 300x450 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12 mm thick cement mortar 1:3 (1 Cement : 3 sand) including grouting the joints with white cement and matching pigments etc., complete. 517 11.53 Providing and laying Antiskid floor tiles of any sizes, 12 mm thickness with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement with matching pigments etc., complete. 518 11.54 Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. 519 11.55 Deduct for not using 20mm thick cement mortar 1:4 (1 cement: 4 sand) bedding in laying of floor tiles. 520 11.56 Fixing glazed/ Ceramic/Rectified/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 521 11.57 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.05% and conforming to IS: 15622 of approved make in all colours and shades for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 522 11.58 Providing and fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: 523 11.59 Providing and laying 500x500x40mm thick Turf paver on 150mm thick sub grade of compacted bed of 20mm nominal size stone aggregate and base course with 50mm thick sand and filling joints with sand including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer- in-charge. 524 11.60 Providing and fixing 10mm thick acid and/ or alkali resistant tiles of approved make and colour using acid and/ or alkali resisting mortar bedding and joints filled with acid and/ or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge. 525 11.60.1 In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement: 4 sand)Acid and alkali resistant tile. 526 11.60.2 In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement: 4 sand).Acid and alkali resistant tile. 527 11.61 8 mm thick.stones Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. 11.61.1 Marble tiles (polished) Raj Nagar. 11.61.2 Granite tile of any colour /shade 528 11.62 Providing and fixing cramps of required size and shape in RCC/ CC /Stone/ Brick masonry backing with cement mortar 1:2 ( 1 cement :2 sand) including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). 11.62.1 Gunmetal cramps. 11.62.2 Stainless steel cramps. 529 11.63 Providing and fixing expansion hold fasteners of wedge expansion type on C.C. / R.C.C./ Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 11.63.1 Fastener with threaded dia 6 mm. 11.63.2 Fastener with threaded dia 10 mm. 11.63.3 Fastener with threaded dia 12 mm. 530 11.64 Providing and fixing stone slab table rubbed on both faces edges rounded and polished of size as required and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. 11.64.1 White Agaria Marble Stone. 11.64.2 Granite Stone of approved shade. 531 11.65 Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer- in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 11.65.1 300 mm Finished Floor Height (FFH) 11.65.2 450 mm Finished Floor Height (FFH). 532 11.66 Providing and laying factory made machine pressed precast cement concrete interlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness, M-30 grade with grey cement and pigment all as specified. Made by block making machine with strong vibratory compaction, laid in required colour and pattern over and including 50mm thick compacted bed of stone dust, filling the joints with sand etc. all complete as per the direction of Engineer-in-Charge. 533 11.67 Providing Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type i/c appropriate hardner and filler material. with 5 year defect liability period (This item is to be used only for operation theaters in hospitals) 11.67.1 1 mm thick 11.67.2 2 mm thick 11.67.3 3 mm thick 534 11.68 Providing and fixing acoustic PVC (Poly Vinyl Flooring) EN (European Standard) over fiberglass mat PVC foam backing (EN 14904), total thickness is 3.25mm (EN 428/EN 427), wear layer is 0.85 mm thick (EN 429), anti-bacterial and anti-fungus surface treatment , chemical resistance test qualified (EN-423)-high resistance, thermal and underfloor heating test qualified (EN12524) - all vinyl sheets must be linked crosswise with a continuous copper strip and finally connected to earth for grounding electrostatic electrical charges. Suitable and slip resistant. Recommended to use in area like Lecturer room, Conference room, Kids area, School, colleges, Residential and all commercial official scope etc. 535 11.69 Providing and fixing 2 mm thick heterogeneous PVC (poly vinyl flooring) EN (European Standard) with wear layer is 0.55mm thick of PVC, total weight is 2300 g/m2 approx. PUR (polyurethane reinforced), residual indentation approx.0.05 mm, castor wheel test qualified, dimensional stability ≤0.10%, static electrical charge .The floor finish should termite free at the room perimeter passing over a concealed cove forming and continuing up on the wall upto100mm. Recommended to use in area like Patient rooms , Doctor room Lecturer room, Kids area, School, Colleges, Residential and all commercial official scope etc. 536 11.70 Providing and fixing 8mm and above thick laminated (wooden flooring) of AC4 and above grade product of approved made out of core high density fibre board (HDF), surface layer shall be high preasure laminated treated for abrasion, scratch, moisture protection, flame protection U.V resistant, layer of acrylic resin, aluminium oxide or similer layer having above properties, backing under layer on min 2 mm thickness shall provide as sound absorbent and moisture protection layer, The seamless impregenated decorative layer of specified size, design, colour and pettern, all bonded together under high temperature and pressure with eco-friendly. The material shall be applicable warranty formaldehyde free, eco- friendly and fully recyclable (eco-freindly) and matching shed and excluding quantity of skirting and profile. 537 11.71 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, 1:6 (1 cement : 6 sand) including filling the joints with same mortar, with common burntclay non modular bricks 11.71.1 100 mm thick 11.71.2 200mm thick 538 11.72 Providing and laying factory made chamfered edge Cement Concrete paver blocks of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658-2006 IS marked made by table vibratory method using PU mould, laid in required colour and pattern over 0.30 mm with courtyards, porch with M 15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in-Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade 11.72.2 60 mm thick C.C. paver block of M-35 grade 11.72.3 60 mm thick C.C. paver block of M-30 grade 539 11.73 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in- Charge). 540 11.74 Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side(top & bottom), including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-Charge. 541 11.75 Providing and fixing 16mm thick gang saw cut mirror polished premoulded and prepolished machine cut Granite of approved shade, colour and texture of Granite Door frame. in cement mortar 1:3 (1 cement :3 sand) Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, towerboltetc complete at all levels as per instruction of Engineer-in-Charge. 11.75.1 Granite Door frame for 100mm thick wall Thickness. 11.75.2 Granite Door frame for 200mm thick wall Thickness. 542 11.76 Providing and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11.76.1 Plain ivory light shade : Size 600X600mm thickness 9-10mm 11.76.2 Dark shade (terracotta) : Size 600X600mm thickness 9-10mm 543 11.77 Providing and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 77.1 Plain ivory light shade : Size 600X600mm thickness 9-10mm 11. 77.2 Dark shade (terracotta) : Size 600X600mm thickness 9-10mm 544 11.78 Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, quality/ premium quality in flooring laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 78.1 In light shade glossy/ rustic /stain finished 11. 78.1.1 Size 600X600 mm thickness 9-10 mm 11. 78.1.2 Size 800X800mm thickness 11-12mm 11. 78.1.3 Size 800X1200 mm thickness 11-12mm 11. 78.2 In dark shade glossy/ rustic /stain finished 11. 78.2.1 (a) Size 600X600 mm thickness 9-10 mm 11. 78.2.2 (b) Size 800X800mm thickness 11-12mm 11. 78.2.3 (c) Size 800X1200 mm thickness 11-12mm 545 11.79 Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 79.1 In light shade glossy/ rustic /stain finished 11. 79.1.1 (a) Size 600X600 mm thickness 9-10 mm 11. 79.1.2 (b) Size 800X800mm thickness 11-12mm 11. 79.1.3 (c) Size 800X1200 mm thickness 11-12mm 11. 79.2 In dark shade glossy/rustic/stain finished 11. 79.2.1 (a) Size 600X600 mm thickness 9-10 mm 11. 79.2.2 (b) Size 800X800mm thickness 11-12mm 11. 79.2.3 (c) Size 800X1200 mm thickness 11-12mm 546 11.80 Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 80.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 80.1.1 (a) Size 300X300 mm thickness 9-10 mm 11. 80.1.2 (b) Size 600X600mm thickness 9-10mm 11. 80.1.3 (c) Size 600X600 mm thickness 11-12mm (to be used heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) 11. 80.2 In dark colour and shade etc. 11. 80.2.1 (a) Size 300X300 mm thickness 9-10 mm 11. 80.2.2 (b) Size 600X600mm thickness 9-10mm 11. 80.2.3 (c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) 547 11.81 Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting, riser laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 81.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 81.1.1 (a) Size 300X300 mm thickness 9-10 mm 11. 81.1.2 (b) Size 600X600mm thickness 9-10mm 11. 81.2 In dark colour and shades etc. 11. 81.2.1 (a) Size 300X300 mm thickness 9-10 mm 11. 81.2.2 (b) Size 600X600mm thickness 9-10mm 548 11.82 Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality including grouting the joints with white cement and matching pigments etc. complete 11. 82.1 For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) 11. 82.1.1 Size 600X600 mm thickness 9-10 mm 11. 82.1.2 Size 800X800mm thickness 11-12mm 11.82.1.3 Size 800X1600 mm thickness 11-12mm 11.82.1.4 Size 1000X1000 mm thickness 11-12mm 11. 82.1.5 Size 600X1200 mm thickness 11-12mm 11. 82.1.6 Size 800X1200 mm thickness 11-12mm 11. 82.1.7 Size 1200X1200 mm thickness 11-12mm 11.82.1.8 Size 1200X1800 mm thickness 11-12mm 11.82.1.9 Size 1200X2400 mm thickness 11-12mm 11. 82.2 For wall stain / rustic finished laid on 12mm thick cement mortar 1:3 (1 cement:3sand) prepared same day when mortar is still green i.e.within 6 hours, Size 300X600 mm thickness 9-10 mm 11. 82.3 For wall polished / Glossy finished laid on 12mm thick cement mortar 1:3 (1 cement:3sand) prepared same day when mortar is still green i.e. within 6 hours, Size 300X600 mm thickness 9-10 mm 549 11.83 Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality / premium in skirting, riser laid our 12mm thick cement mortar 113 including grouting the joints with white cement and matching pigments etc. complete 11. 83.1 For skirting, risers etc. glossy/ rustic /stain/matt finished in all colours and shades 11. 83.1.1 Size 600X600 mm thickness 9-10 mm 11. 83.1.2 Size 800X800mm thickness 11-12mm 11. 83.1.3 Size 600X1200 mm thickness 11-12mm 11. 83.1.4 Size 800X1200 mm thickness 11-12mm 550 11.84 Granite work gang saw cut (polished machine cut) of thickness 12 mm for wall lining, skirting, risers of steps and dado (veneer work), back filling with a grout of average 12 mm thick in cement mortar 1:3 (1 Cement: 3 sand) including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the beaching by means of cramps, which shall be paid for separately). 11. 84.1 Area of tiles not less 0.18 sqm 11. 84.1.1 Fine granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter 11. 84.1.2 Course granite light Black/light Red/ off White with crystals of other colors and various patterns 11. 84.1.3 Gray/Pink/Brown with various patterns 551 11.85 Providing and laying gang saw cut 12mm thick, mirror polished pre moulded (wherever required) and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in flooring laid over 20mm thick base of cemnt mortar 1:4(1cement:4sand) including grouting the joints with white cement mixed with matching pigments, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 11. 85.1 Area of tiles not less 0.18 sqm 11. 85.1.1 Fine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter 11. 85.1.2 Coarse grained granite light Black/light Red/ off White with crystals of other colors and various patterns 11. 85.1.3 Gray/Pink/Brown with various patterns 552 11. 86 Providing and fixing artificial synthetic green long and fine yarns grass, UV/water resistant with SBR latex backing eco-friendly durable high density 100 % PP ( Poly Poplin ) anti UV fiber.denier 12000 dtex, stich rate 18 stiches per 10cm, stich density 16800 stiches/m2, tufted weight 1830g/sqm approx. 11. 86.1 Roll size will be 25.00m X 2.00m (25mm thick)- weight 150kg- per roll. 11. 86.2 Roll size will be 25.00m X 2.00m (40mm thick)- weight 180kg- per roll. 553 11.87 Providing and fixing laminated (engineered wooden flooring) of suitable thickness 10-14 mm of suitable grade category product of approved made out of core high density fibre board (HDF) &other component it treated for abrasion ,scratch ,moisture protection, flame protection,U.V resistant. backing with eco- friendly resins specified by the manufacturer .The material shall be applicable warranty formaldehyde free, eco friendly, highly recommended for high traffic area and fully recyclable and matching shed and excluding quantity of skirting and profile. 554 11.88 Providing and fixing single layer homogeneous (solid wooden flooring) of suitable thickness 14 - 18 mm of suitable grade category product of scratch protection, moisture protection, flame protection U.V. resistant, backing under layer on min 2 mm thickness The material shall be applicable warranty formaldehyde free, eco friendly ,highly recommended for high traffic area and fully recyclable and matching shade and excluding quantity of skirting and profile. 555 11.89 Providing and fixing tuffed 1/10” loop pile (carpet tile / Carpet). EN (Euorpean Standard) size 50cm x 50cm /roll Size of total thickness 5.5 mm and above with total mass of 4100g/m2approx and with polyester fleece primary backing with standard dimensional stability with impact sound / noise reduction and recommended for high traffic acoustical area. 556 11.90 Providing and fixing spc (stone plastic composite) virgin pvc water resistant proof vinyl flooring with a thickness between 4 to 8mmuv coated layer with a wear layer of 0.3 to 0.80mm with a SPC core layer of 2.00 to 5.00 mm with a SOP of heat resistant, voc free, easy to cut, anti microbial protection in the form of tiles, planks helpful in environmental of profection health. 557 11.91 Providing and laying pre mirror polished/ pre polished fine grain machine cut sand stone tile flooring 20mm thick (hardness should not be less than 7 and water absorption should not be more than 0.3%) of required size and shape of approved shade, flooring in plazas open staircase and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joint with white cement mix with matching pigment etc. complete as per direction of Engineer-in-Charge. 11. 91.1 300x300mm 11. 91.2 400x400mm 11. 91.3 600x600mm 558 11.92 Providing and laying pre mirror polished/ pre polished fine grain machine cut sand stone slab flooring 20mm thick (hardness should not be less than 7 and water absorption should not be more than 0.3%) of required size of area more then .50 sqm and shape of approved shade, flooring in plazas open staircase and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joint with cement mix matching pigment etc. complete as per direction of Engineer -in-Charge. 559 12.1 Providing corrugated G.S. Sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.00mm thick with zinc coating not less than 275gm/m² 12.1.2 0.80mm thick with zinc coating not less than 275gm/m² 12.1.3 0.63 mm thick with zinc coating not less than 275gm/m² 560 12.2 Straight cutting in G.S. sheet of any thickness roofing for making opening of area exceeding 40 sq. decimetre for chimney stacks, sky light etc. 561 12.3 Extra for circular cutting in C.G.S. sheet of any thickness roofing for making opening of area exceeding 40 square decimetre : 562 12.4 Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 12.4.1 0.80mm thick with zinc coating not less than 275gm/m² 12.4.2 0.63mm thick with zinc coating not less than 275gm/m² 563 12.5 Providing valleys of 90cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia. G.I. limpet and bitumen washers complete. 1.60 mm thick with zinc coating not less than 350gm/m² 564 12.6 Providing and Fixing of 40 cm over all width plain, G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts, G.I. limpet and bitumen washer complete, bent to shape and fixed in wall with cement mortar 1:3 (1cement : 3 sand). 1.00mm thick with zinc coating not less than 275gm/m² 565 12.7 Providing and fixing 15 cm wide 45 cm over all semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 12.7.1 0.80mm thick with zinc coating not less than 275gm/m² 12.7.2 0.63mm thick with zinc coating not less than 275gm/m² 566 12.8 Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia.G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. 567 12.9 Extra for straight cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated, semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter for chimney stacks, skylights etc.. 568 12.10 Extra for circular cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated/ semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter. 569 12.11 Extra for providing and fixing wind ties of 40x 6 mm flat iron section. 570 12.12 Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. 12.12.1 Corrugated serrated adjustable ridges 12.12.2 Plain wing adjustable ridges 12.12.3 Close fitting adjustable ridges 12.12.4 Unserrated adjustable hips 571 12.13 Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: 12.13.1 Corrugated apron pieces 12.13.2 Eaves filler pieces 12.13.3 North light curves 12.13.4 ventilator curves 12.13.5 Barge boards 12.13.6 Ridge finials 12.13.7 Special north light curves 12.13.8 S type louvers 572 12.14 Providing flat iron brackets 50x3mm size with necessary bolts, nuts washers etc. for fixing G.S. sheets gutters with purlins. 573 12.15 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS:277 in 240 mpa steel grade, 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 574 12.16 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self- tapping screws complete : 12.16.1 Ridges plain (500 - 600mm). 12.16.2 Flashings/ Aprons.( Upto 600 mm) 12.16.3 North light curves. 12.16.4 Barge board (Upto 300 mm) 12.16.5 Crimp curve 12.16.6 Gutter. (600 mm over all girth) 575 12.17 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 12.17.1 2mm thick corrugated (2.5 or 4.2 or 6) or step-down (2or 3or 6) as specified. 12.17.2 2mm thick flat. 576 12.18 Providing and Fixing of sky lights consisting of Multi cell/tight cell Polycarbonate Panel System of approved colour, 16 mm thick (minimum) having uniform in color with an integral Tight-Cell core constructed not to exceed 4mmx4mm in a cross section, involved such as bolts nuts and screws etc. and labour for cutting bending to required profile, necessary scaffolding, hoisting in position etc. for proper completion of the work etc. complete as per specification drawings and direction of Engineer in charge. Finished surface area of roofing fixed over steel tubular structure shall be measured for payment. MS tabular frame work shall be measured separately for payment. 12.18.1 10mm thick 12.18.2 16mm thick 577 12.19 Providing sand stone slab 40 to 50 mm thick for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately) including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 sand ) complete : 12.19.1 Red sand stone slab 12.19.2 White sand stone slab : 578 12.20 Painting top of roofs with residual type petroleum bitumen of grade VG 10 of approved quality @ 17kg per 10 sqm impregnated with a coat of sand at 60 cum per 10sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 579 12.21 Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance and thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall be strictly as per manufacturers specifications and as approved by engineer In charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., and washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer-in-charge. 580 12.22 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection >0.70 and initial emittance >0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 581 12.23 Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 sand) and finished neat complete. 582 12.24 Providing and fixing on roof pressed clay tile (Mangalore tile) 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 583 12.25 Providing and laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness of approved pattern on steel frame work complete (steel frame work to be paid separately) 584 12.26 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 sand) as per standard design : In 75x75mm deep chase 585 12.27 Making khurras 45x45 cm (sunk area) with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 sand) and a coat of neat cement rounding the edge and making and finishing the outlet complete so as to receive rain water/ spillage water on roof in a sunk area and completely rain out in a near perfect strain meter motion into rain water pipe. 586 12.28 Providing and fixing M.S. holder bat clamps of approved design to C.I. Or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. 12.28.1 100 mm diameter 12.28.2 150 mm diameter 587 12.29 Providing and fixing ISI marked sand cast iron rain water pipes. 12.29.1 100 mm dia minimum wall thickness 5mm 12.29.2 150 mm dia minimum wall thickness 5mm 588 12.30 Providing lead caulked joints to sand cast iron rain water pipes and fittings : 12.30.1 100 mm dia. Pipe 12.30.2 150 mm dia. Pipe 589 12.31 Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately) : 12.31.1 Sand cast iron bend : 12.31.1.1 100 mm diameter 12.31.1.2 150 mm diameter 12.31.2 Sand cast iron plain shoes : 12.31.2.1 100 mm diameter 12.31.2.2 150 mm diameter 590 12.32 Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.32.1 75 mm diameter (minimum wall thickness 1.8mm) 12.32.2 110 mm diameter (minimum wall thickness 2.2mm) 591 12.33 Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.33.1 Coupler 12.33.1.1 75 mm (minimum wall thickness 1.8mm) 12.33.1.2 110 mm (minimum wall thickness 2.2mm) 12.33.2 Single push fit Coupler : 12.33.2.1 75 mm (minimum wall thickness 1.8mm) 12.33.2.2 110 mm (minimum wall thickness 2.2mm) 12.33.3 Single tee with door 12.33.3.1 75x75x75 mm (minimum wall thickness 1.8mm) 12.33.3.2 110x110x110 mm (minimum wall thickness 2.2mm) 12.33.4 Single tee without door 12.33.4.1 75x75x75 mm (minimum wall thickness 1.8mm) 12.33.4.2 110x110x110 mm (minimum wall thickness 2.2mm) 12.33.5 Bend 87.5° 12.33.5.1 75 mm bend (minimum wall thickness 1.8mm) 12.33.5.2 110 mm bend (minimum wall thickness 2.2mm) 12.33.6 Shoe (Plain) 12.33.6.1 75 mm Shoe (minimum wall thickness 1.8mm) 12.33.6.2 110 mm Shoe (minimum wall thickness 2.2mm) 592 12.34 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 12.34.1 75 mm (minimum wall thickness 1.8mm) 12.34.2 110 mm (minimum wall thickness 2.2mm) 593 12.35 Providing and fixing to the inlet mouth of rain water pipe fixing cast iron grating 15 cm diameter and weighing not less than 440 grams. 594 12.36 Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms. 595 12.37 Providing and fixing 100 mm/110 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 sand) 12.37.1 Stone ware spout 12.37.2 Upvc spout (Pipe dia.110 mm) 596 12.38 Providing and fixing of self-supported mechanically seamed roofing system, made of high quality steel, having 340 MPA yield strength, pre coated galvalume sheet as per ASTM A 792 M of base metal thickness from 0.8 mm to 1.6mm (tolerance ± 0.02mm). High grade steel sheet should have 55% aluminum and 45% zinc coating by hot-dip process of minimum 25 micron The rate includes supplying, fixing, loading unloading, hire charges of all plants machineries, anchors, fasteners, washers, bolts, epoxy, paint and all wastage etc. complete. Accessories and fixtures like hangers/clamps for installation of lighting /fixtures /utility/ duct as per requirement and ventilators, skylight can also be provided at crown/ridge by making cuts into the panels which is to be paid separately. This item shall be executed only by the agency which has all required manufacturing machineries and necessary expertise. 12.38.1 Base metal thickness 0.8mm up to span 15 meter 12.38.2 Base metal thickness 0.9mm , up to span 18 meter 12.38.3 Base metal thickness 1.0 mm, up to span 21 meter 12.38.4 Base metal thickness 1.1 mm, up to span 23 meter 12.38.5 Base metal thickness 1.2mm, up to span 25meter 12.38.6 Base metal thickness 1.3 mm, up to span 27 meter 12.38.7 Base metal thickness 1.4mm, up to span 29meter 12.38.8 Base metal thickness 1.5 mm, up to span 31 meter 12.38.9 Base metal thickness 1.6 mm, up to span 33 meter 12.38.10 Providing and fixing galvalume 1.0 mm thick clamps/hangers of size 75X140mm with saddle of 50mm dia, riveted at one side and nut and bolt at other side, to self-supported roofing system by mechanical seaming to suspend light fixture/cable stay/false ceiling/duct etc., at their location which should be planned earlier by engineer-in-charge. Clamps shall be fixed during seaming of panels. 12.38.11 Providing and fixing advanced type hurricane turbo ventilator to self- supporting roof having neck dia 600mm made of aluminum having 24 nos vertical vanes made of aluminum sheet. Ventilator should be fixed on 1 to 2mm thick G.I. ring which shall be fixed on 2mm thick polycarbonate sheet. Polycarbonate sheet shall have foam tap or rubber gasket under and over it and fixed by 1 to 2 mm thick aluminum angle 25X25mm with self- tapping screw to panels. All joints shall be sealed by silicon. Rates i/c of all material, labour fittings screw, rings, foam tap, aluminum angles etc. complete. Deduction shall not be made for cutting area of self-supported roof. 12.38.12 Providing and fixing of 2mm thick polycarbonate sheet to self-supported roofing system. The sheet shall have tensile strength and elongation as per ASTM D 638, refractive index as per ASTM D 592, light transmission as per ASTM D 1003 and specific gravity as per STM D 792. Polycarbonate sheet shall have foam tap or rubber gasket under and over it and fixed by 1 to 2 mm thick aluminum angle 25X25mm with self- tapping screw to panels. All joints shall be sealed by silicon. Rates include of all material, labour, fittings, screw, foam tap, aluminum angles etc. complete. Deduction shall not be made for cutting area of self-supported roof. 597 12.39 Supply, fabrication and erection of three-dimensional space frame steel structure consisting of support node, primary space frame members, space notes nodes, bolts, sleeves (nut), purlin stool, purlin etc. to support roof sheet in plain or curved shape. (Approximate zinc coating thickness 77 Microns) and shall not be less than 400 g/sqm (Approximate zinc coating thickness 56 microns). Bolts, sleeves and cones shall be electro-galvanized to ASTM B 633 Type 2, SC3. Shop drawings along with structural design analysis shall be provided by the manufacturer for approval of the engineer in charge. Rate shall include cost of design, all material, all lifts, labour, transport, storage, machines, tools and plants, wastages, erection and installation at site all necessary scaffolding etc. necessary to provide finished product but excluding cost of erection/construction of support shaft and roof sheet. 598 12.40 Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). 599 12.41 Providing and fixing in position roof tile under lay using 12mm thick(minimum) Moisture/fire Resistance heavy duty fibre cement board(High Pressure Steam Cured) Type A,Category 4 conforming to IS 14862:2000, fixed on Steel frame work of 610mmx610mm or 610mmx1220mm grid by counter sunk stainless screw @ 300mm C/C all complete as per the drawings. Tiles etc may be laid on the board substrate by sealing the joints properly with filler material or sealant to ensure no leakage through joints. All complete as per drawings, specification and as per direction of Engineer-in-Charge.Note - MS Section structure and roof tile like Shingles/Mangalorian Tiles etc cost will be paid seprately. 600 12.42 Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS: 8183 density 24kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. 601 12.43 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8183, density 16kg/m3, 50mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire. 602 12.44 Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge : 603 12.44.1 With Type N - Normal 50 mm thick 604 12.44.2 With Type SE - Self Extinguishing type 50 mm thick. 605 12.45 Providing and laying thermal insulation of roofing with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1: 2 : 4 (1 cement : 2 sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 mx2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. 606 12.46 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in- Charge. 607 12.47 Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183, density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. 608 12.48 Providing and fixing thermal insulation with Resin bonded rock wool conforming to IS: 8183, density 48 kg/m3, 50 mm thick, wrapped in 200 G virgin Polythene bags placed over existing false ceiling and held in position by criss- crossing GI wire. 609 12.49 Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3. 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge. 610 12.50 Supply and application of 48kg/m3 density & 50 mm thick with a tolerance of -2 + 6mm of Rockwool RB slabs unfaced (Binder<3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non- combustible when tested as per BS 476 Part 4 or A1 when tested as per EN: 13501. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 611 12.51 Supply & Application of Rockwool RB slab 48kg density, 50mm thick wrapped in 200G vergine polythene bags for partition, ceiling (Under Deck insulation) conforming to IS: 8183 with tolerance of -2 +6mm of rock wool RB slabs unfaced (Binder <3.5%) conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS 476 Part 4 or Al when tested per EN 13501. . Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 612 12.52 Supply & Application of Rockwool RB 2 slab 64kg /m3, 50mm thick, with GI wire netting 24 SWG; fixing for NRC Value 1.00 for Acoustics, thermal & fire purpose conforming to and IS: 8133, IS: 8183 with tolerance of -2 + 6mm of RB slabs unfaced (Binder < 3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Two random samples from each supplied batch will be tested for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 613 12.53 Supply & Application of Rockwool building roll (1.1mx10m) 48kg density, 50mm thick with FSK (foil scrim Kraft) aluminium foil facing for HVAC duct & building underdeck purpose conforming to IS: 8183, IS: 8183 and IS:8183 a tolerance of -2 +6 mm of Rockwool RB slabs unfaced (Binder < 3.5%) ; conforming to IS: 8183; /ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS: 476 Part 4 or Al when tested as per EN: 13501. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and it shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 614 12.54 Supply & Application of Rockwool Building Roll (1.1mX10m) 48kg density, 50mm thick with ALG (Alu & glass) mixture of Aluminium & glass facing for building underdeck application below metal sheet also conforming IS: 8183, IS: 8183 and IS: 8183 a tolerance of -2+6mm of rockwool RB slabs unfaced (Binder < 3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS 476 Part 4 or Al when tested as per EN 13501. The maximum service temperature shall be 700°C. Shot content should be less than 2% for 500 microns & less than 10% for 250 microns when tested as per standard IS: 3144. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 615 12.55 Providing and fixing of minimum 12mm thick, 5 layered bubble Reflective thermal insulation made of 12 microns aluminum foil with minimum 97% Reflectivity on both outer sides, under both aluminum foil 4mm thick FR bubble insulation with Low Emissivity - 0.032 (ASTM1371), Fire Class A (ASTM E84) All five layers of insulation shall be stick with each other by registered manufacturer using hot process without using any kind of adhesive. Insulation shall be supplied in 1.10m wide roll width with 50mm wide factory-made cuts at both sides to joint another roll by using general stapler in case of new shed and adhesive in case of existing or self-supported roof. 12.55.1 Fixing of insulation on new work by laying horizontally on the purlins and perpendicular to the direction of purlins and fixing by using self- tapping screws at equal distance. Place and align the second roll of insulation parallel to the first roll and overlaps the adjacent rolls. After Insulation is fixed over the purlins the metal sheet is placed over insulation and drilled with self-tapping screws with purlins etc. complete, including all material and scaffolding. 12.55.2 Installation of insulation in Old Sheds where the sheets have been already fixed over the purlins so insulation shall be fixed under the purlins covering the roof bottom. Insulation roll to be unfolded at the bottom of the purlin horizontally and parallel to the roof and fixed by using the self- tapping screw with a washer at equal distance etc. Complete, including all material and scaffolding. 12.55.3 Insulation of Self-Supported Roof shall be applied under the roofing by using stud welding to the self- supported roof at a distance not be more than 300 mm in both directions. At each stud insulation roll shall be pushed against the studs so that it gets punctured and then non-returning washer has to be applied at the stud etc. complete, including all material and scaffolding. 616 12.56 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board (XPS) of required size over- deck on ceiling surface, complying with ASTM C 578 - type VI, having thermal conductivity of 0.0289 W/mK as per ASTM C 518, compressive strength of > 350 kPa listed as per ASTM C 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorption < 1% by volume as per ASTM C 272, oxygen index of minimum 24 as per ASTM D 2863 and Fire retardant property as per DIN 4102, with preferred stone or pre-cast tiles shall be laid over the XPS board with suitable grouting including providing pre-fabricated EPDM drain outlets (Cement Screed casting shall be done at the junction of roof and parapet walls), all as per the directions of Engineer-in-charge. 617 12.57 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge. 618 12.58 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 12.58.1 10mm thick plaster of Paris (gypsum anhydrous) sheet 10mm thick pop board 12.58.1.1 Flat surfaces 12.58.1.2 Curved surfaces 12.58.1.3 Sunk or raised mouldings 12.58.1.4 Extra for providing in the plaster of Paris (Gypsum anhydrous) ceiling above 5 metre height from floor level. 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.1 Plain board conforming to IS: 2095- Part I : 2011 (Board with BIS certification marks). 12.58.2.2 Fire resistant Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) 12.58.2.3 Gypsum moisture resistant board. 12.58.2.4 Fully Perforated Gypsum Plaster Board having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturers specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. 12.58.3 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. 619 12.59 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of mainT runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.59.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 12.59.2 GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 12.59.3 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a ompletely sealed unit. 12.59.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 12.59.5 Glass fiber Acoustical Suspended Ceiling System with 16 mm thick tegular edge or micro look edge tiles of size 595x595mm.The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance ≥83%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and7) in module size of 600 x 600 x 16mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 38 - 41%. The Tile and Grid system used together should carry a 15 year warranty. 12.59.6 8mm thick non-asbestos multipurpose termite, fire & moisture resistance cement bonded particle board as per IS: 14276, white primedcolour tiles of size 595X595 mm. 12.59.7 6mm thick non-asbestos multipurpose termite, fire & moisture resistance cement bonded particle board as per IS: 14276, white primed colour tiles of size 595X595 mm. 620 12.60 Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20mm made of 0.5mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300mm center to centre, suspending the main C carrier and in direction perpendicular to it at 600mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive) Fixing with clip in/swing down tiles into spring T with 12.60.1 GI Metal Ceiling Clip in /swing down plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 12.60.2 GI Metal Ceiling Clip in /swing down plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. 621 12.61 Providing & Fixing of Unperforated Antibacterial Metal Tile Ceiling System comprising of Tile of 600mm wide and 600mm long manufactured out of 0.7mm thick aluminium alloy 3105 with beveled edge of 4.15mm width and height of 32mm. The Tile will be manufactured on advanced equipment that includes several levelling stages in the manufacturing process by approved certified manufacturers. The Tile shall be clipped into clip in rail of 0.5mm thick G.I. in form of a grid system using a cross connector. The clip in rail shall be supported from slab by means of rigid Suspension of 4mm G.I.Road, Hold on Clamp with Clip. (Rate include all materials and labour). 622 12.62 Providing and fixing board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately): 12.62.1 12mm thick insulating board 12.62.1.1 Natural colour insulating board 12.62.1.2 White face insulating board 12.62.1.3 Flame retardant face insulating board 12.62.2 Flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 12 mm thick marked in ceiling with necessary nails etc. complete 12.62.3 6 mm thick plain Multipurpose Cement board ( High Pressure steam cured ) as per IS : 14862, with suitable screws for fibre cement board in ceiling etc. complete 12.62.4 6mm thick High Pressure Steam Cured non asbestos, reinforced with cellulose fibres,Moistur& fire Resistance heavy duty fibre cement board, Type A,Category 4 conforming to IS 14862:2000.(for wet areas) 12.62.5 4 mm thick High Pressure Steam Cured non asbestos, pre-painted, self- embossed, designer cement boardType B, Category 3 conforming to IS 14862:2000 . of approved texture,design patterns 623 12.63 Extra for Circular cutting and wastages in ceiling with: board only (frame work) Natural colour insulating 12 mm thick board paid separately. 624 12.64 Extra for providing and fixing ceiling to curved surfaces in narrow widths 625 12.65 Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminium primer on both sides and edges including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately). 626 12.66 Providing and Fixing colour coated profile sheet of minimum 1015 mm effective cover width and nominal 28.5 mm deep ribs with subtle square fluting in the five pan at nominal 203 mm centre-to-centre. The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The sheet shall have brand marking of the manufacturer giving product details on the back of the sheet at every 1 meter c/c for confirming genuinity of the material. The sheet shall be fixed using self- drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape 627 12.67 Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain or design particle board ceiling tiles. 628 12.68 Providing and fixing expanded polystyrene (thermacol) false ceiling (frame work to be paid separately) : 12.68.1 With Type N - Normal 50 mm thick 12.68.2 With Type SE - Self Extinguishing type 50 mm thick 629 12.69 Providing and fixing false ceiling with fabric fixing with nail etc. (frame work and beading to be paid separately). 12.69.1 costing upto 70/- per metre, 12.69.2 Rs 70- 150 per meter 12.69.3 Upto 200 per meter 630 12.70 Providing and fixing perforated Aluminium panel ceiling of white/ natural satin colour supplied by approved manufacturers consisting of panel of standard size with bevel edge, panel length up to 6 m, coil Coated on a Continuous Paint Line suitable for Interior application, double baked and roll formed from enamelled corrosion resistance aluminium alloy AA 5050 (Al. Mg) for higher strength and good roll forming characteristics. Panel carrier shall be suspended by means of G.I. threaded rod having 6 mm diameter at a distance of 1.5 mtr. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 12.70.1 With panels of size 300mm wide X30mm deep X 0.7mm thick and panel carrier of size 40.5mm wide X 62mm deep X 0.9mm thick 12.70.2 With panels of size 150mm wide X 15.5 mm deep X 0.5mm thick and panel carrier of size 32mm wide X 39mm deep X 0.95mm thick 12.70.3 With panels of size 84mm wideX16mm deep X 0.5mm thick and panel carrier of size 62mm wide X 29mm deep X 0.95mm thick 631 12.71 Providing and fixing un-perforated Aluminium Panel ceiling Supplied by approved manufacturers of standard white/ natural satin shade consisting of panel 30 mm/80mm/130mm/180mm wide X 15 mm deep X 0.5mm /0.6mm thick respectively, with square edges having panel length up to 6 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 5050 (Al.Mg) for higher strength and good roll forming characteristics. The Carrier shall be suspended by means of G.I. suspension rod 4mm diameter, and a Galvanised suspension spring clip at a distance of 1.7mtrs centre to centre. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 632 12.72 Providing and fixing U Baffle Aluminium panel ceiling of different colors and finish supplied by approved manufacturers, consisting of panel size 50 mm width X 100 mm deep using 0.6 mm thick, panel length upto 4 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3005 (Al. Mg) for higher strength and good roll forming characteristics. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The measurements shall be wall to wall without any deductions for lights, diffuses, columns etc. As an option, ceiling area above U Baffle can be painted by the contractor in black colour or any other colour as per the architect for better aesthetics before fixing this system. 12.72.1 Standard White / Natural Satin Shade 12.72.2 Wooden Finish 633 12.73 Supply & Fixing of perforated G.I false ceiling tile or plank using torsion spring fixing system supplied by approved manufacturer comprising of tile of 600 mm wide and 600 mm long manufactured out of 0.5 mm thick or plank of 600mm wide and 1200 mm long manufactured out of 0.6mm thick galvanised steel perforated with 2 mm dia. at a distance of 5mm centre to centre. Non-woven felt made of glass- reinforced fibre glued over the perforation at the back side of panels to provide noise reduction co efficient up to 0.7 NRc. “Tee” sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on centre spacing to match panel length. Cross runners 24 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced at a spacing of 600 mm on centre maximum. The measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 12.73.1 Tile of 600 mm wide ,600 mm long and 0.5 mm thick 12.73.2 Plank of 600mm wide ,1200 mm long and 0.6mm thick 634 12.74 Providing and fixing of composite perforated Gypsum board with Glass wool Fiber panel of Size 595x595x25 mm with 10mm square Perforation tiles false ceiling in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “ “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 635 12.75 Providing and fixing of Composite perforated MDF board with Glass wool Fiber panel of Size 595x595x18 mm 10mm Square Perforation tiles (Square /Tegular Edge) false ceiling in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 636 12.76 Providing and fixing of Perforated Gypsum board with Acoustical Glass Fiber Tissue faced panel of Size 595x595x12.5mm, Square 10mm Perforation tiles (Square Edge) false ceiling panels in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 637 12.77 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance≥ 85%, Thermal Conductivity k = 0.052 -0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling usinggalvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) 638 12.78 Providing and fixing false ceiling at all heights with 15 mm thick integral densified micro look edged non- cementitious light weight calcium silicate false ceiling tile reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.80 grams per sqm) i.e. 50 mm long, 12 mm outer diameter M-6 dash fasteners with the help of Z cleat of 27x37x27x2 mm, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 639 12.79 Providing and fixing false ceiling at all heights with 15 mm thick integral densified mirolook edge with BIO SAFE coating as per ISO 7251:2005, ISO 20743:2007 and ISO 21527-1:2008, making the tiles resistant to bacterial growth in case of any external bacterial contact made onto the surface of tiles, non-cementitious light weight calcium silicate false ceiling tile reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm with the help of Z cleat of 27x37x27x2 mm, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 640 12.80 Providing and fixing in position wall panelling at all heights with 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles., non-cementitious, reinforced with fibre and natural filler, having NRC (Noise Reduction Coefficient) of 0.10-0.20 for plain and designer 0.15-0.40 for pinhole texture and NRC 0.45-0.65 for fully perforated tiles as per IS 8225:1987, sound attenuation STA-32db. of 0.75 (minimum) as per IS 8225:1987, Light Reflectance of 85% (minimum), non-combustible as per BS:476 (part-4), 50-52% recycled content including fly ash, The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fibre joint tape roll 50mm wide (90 metre) roll and two coats of primer suitable for panelling as per manufacturers specification as per direction of engineer-in-charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles. 641 12.81 Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. 12.81.1 With semi perforated 12mm thick micro tegular edged GRG false ceiling tiles. 12.81.2 With fully perforated 10mm thick square edged GRG false ceiling tiles for sound proof and acoustic. 642 12.82 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped 387alvanized steel sections (387alvanized387 @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cros‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer- in-Charge.Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 643 12.83 Providing and fixing upvc plank, Plank size (340 X 2700 ) mm as per approved shade, the panel shall be laser catted end of plank fixing j-trim fixed and corner edge of ceiling fixed u pvc clip same colour and providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 125 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular,j trim end clip includes in this item any other item not be paid sepratly complete in all respect as per the directions of Engineer-in-Charge. . 644 12.84 Providing & Fixing PVC ceiling system profile panel with click system interlock panel size 4000mmx340mmx1mm resistance to weather perfect finish in wood grain & solid colour maintenance free Resistance to weather truly anti bacterial. with edge profile J-trim on periphery & center profile T-trim in panel joint Complete System to be fixed on G.I. framework of ceiling section at 450 mm distance with enter section suspended by roof by G.I. angle hanger in proper line & level etc complete . PRODUCT SPECIFICATIONS: Meets or exceeds the standard specification of (ASTM D-4477) and its referenced documents. observed. (Tested at 50 LBS) Tensile strength, MPa: >37.0 Tensile modulus, MPa: >2000 Surface distortion: None at 120F Squareness: <1/8” of square Length: Within ¼” of specification Lock control: Complies Color Change: <2 grayscales (16 hrs under 1200W/m2 UV radiation at 50 degrees) 645 12.85 Design built, supply and erection of Tensile (fabric) structure system including designing and fabrication in M.S. steel tubular structure as per Indian standard section as per approved design and shape including base plate, dash fastener, clits etc. Cutting, patterning, plotting and wielding of fabric with the help of tensile structure software. Fabric should be wielded by high frequency PVC wielding in proper line with PVC cader to be fixed on end of the fabric and to be stretched & fixed on M.S. design structure with the help of. M.S. Flat bar with self-taping screw. M.S. structure to be painted with one coat of epoxy primer with MRF PUpaint of approved colour in desired shape. With 1050 GSM tensile fabric 12.85.1 With precontraint tensile membrane 1050 GSM (20 years Warranty) 12.85.2 With precontraint tensile membrane 1050 GSM (15 Years warranty) 646 13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement : 4 sand) 13.1.2 1:6 (1 cement : 6 sand) 647 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix 13.2.1 1:4 (1 cement : 4 sand) 13.2.2 1:6 (1 cement : 6 sand) 648 13.3 20 mm cement plaster of mix : 13.3.1 1:4 (1 cement : 4 sand) 13.3.2 1:6 (1 cement : 6 sand) 649 13.4 12 mm cement plaster finished with a floating coat of neat cement of mix : 13.4.1 1:3 (1 cement : 3 sand) 13.4.2 1:4 (1 cement : 4 sand) 650 13.5 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 13.5.1 1:3 (1 cement : 3 sand) 13.5.2 1:4 (1 cement : 4 sand) 651 13.6 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 sand) finished with a top layer 6mm thick cement plaster 1:4 (1 cement : 4 sand). 652 13.7 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 sand) finished rough with sponge. 653 13.8 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) 654 13.9 6 mm cement plaster 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 655 13.10 Neat cement punning 656 13.11 Rough cast plaster upto 10m height above ground level with a mixture of sand and gravel or crushed stone from 6mm to 10mm nominal size dashed over and including the fresh plaster in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 sand) and top layer 10mm cement plaster 1:3 (1 cement: 3 sand) mixed with 10% finely grounded hydrated lime by volume of cement. Finished with ordinary cement. 657 13.12 Pebble dash plaster upto 10m height above ground level with a mixture of washed pebble or crushed stone 6mm to 12.5mm nominal size dashed over and including fresh plaster in two layers under layer 12mm cement plaster 1:4 (1 cement: 4 sand) and top layer 10mm cement plaster with cement mortar 1:3 (1 cement: 3 sand) mixed with 10% finely grounded hydrated lime by volume of cement. 658 13.13 Providing sand faced plaster upto 10meter hight above ground level concrete or brick masonry surfaces in two coats, base coat of 13 mm thick in cement mortar 1:4 (1 cement: 4 sand), clearing the surface by combing it and finishing coat of 8 mm. thick in cement mortar 1:3 (1 cement: 3 sand) and taking out surface grains by mechanical arrangement or applying second coat by mechanical means including cost of all material, labour, and T and P including all lead, lift and scaffolding etc. complete. 659 13.14 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 660 13.15 Extra for plastering 13.15.1 Exterior walls of height more than 10 m from ground for every additional height of 3 m or part thereof 13.15.2 Interior walls of height more than 6 m from floor level for every additional height of 3 m or part thereof 661 13.16 Extra for plastering on circular work not exceeding 6 m in radius: 13.16.1 In one coat 13.16.2 In two coats 662 13.17 Extra for plastering done on moulding cornices or architraves including neat finish to line and level: 13.17.1 In one coat 13.17.2 In two coats 663 13.18 Extra for plastering Spherical, Groined ceiling, Flewing soffits. 13.18.1 Spherical ceiling 13.18.2 Groined ceiling 13.18.3 Flewing soffits 664 13.19 Washed stone grit plaster on exterior walls of height upto 10 M. above ground level in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement : 1/2 sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings,complete as per specification and direction of Engineer- in- charge (Payment for providing grooves shall be made separately). 665 13.20 Forming groove of uniform size 20 or 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 666 13.21 Extra for washed grit plaster on exterior/interior walls of height more than 10m from ground/floor level for every additional height of 3 m or part thereof. 667 13.22 Extra for washed stone grit plaster on circular work not exceeding 6m in radius (in two coats). 668 13.23 Forming groove of uniform size from 12x12mm and upto 25x15mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. 669 13.24 Extra for using white cement in place of ordinary cement in the top layer of the item of washed stone grit plaster. 670 13.25 Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part -1 and II) 1976, applied on hacked/ uneven background such as bare brick/ block/ RCC work on walls and ceiling at all floors and locations,excluding in wall which may come in contact with dampness finished in smooth line and level etc. complete. 671 13.26 Extra for addition of synthetic Polyester triangular fibre of length 6mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement plaster/mortar by using 125gms. Of synthetic Polyester triangular fibre for 50 Kgs. cement used in cement mortar as per directions of Engineer-in-Charge. 672 13.27 Providing and fixing mesh in vertical and horizontal junction of RCC and brick/AAC work including scaffolding and all lead and lift etc. complete 673 13.27.1 G.I. chicken mesh as per ISI specification and in the required width with 50mm long Bombay nails before plastering upt 10 meter height. 13.27.2 Providing and fixing fibre mesh of 145 GSM weight in required width with cement mortar before plastering upto 10m height. 674 13.28 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 sand) : 13.28.1 Flush Band 13.28.2 Sunk Band 13.28.3 Raised Band 13.28.4 Moulded Band 675 13.29 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 sand): 13. 29.1 Flush Band 13. 29.2 Sunk Band 13. 29.3 Raised Band 13. 29.4 Moulded Band 676 13.30 18 mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1:5 (1 cement : 5 sand) top layer 6mm thick with cement mortar 1:4(1 cement : 4 sand). 677 13.31 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 sand) : 13.31.1 Flush / Ruled/ Struck or weathered pointing. 13.31.2 Raised and cut pointing 13.31.3 Sunk pointing 678 13.32 Pointing on stone work with cement mortar 1:3 (1 cement: 3 sand). 13.32.1 Flush/ Ruled pointing 13.32.2 Raised and cut pointing 679 13.33 Raised and cut pointing on stone work in white cement mortar 1:3 (1 white cement : 3 marble dust) 680 13.34 Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 sand): Flush/ Ruled pointing 681 13.35 Extra for pointing on walls on the outside/inside at height more than 10 metre from ground/floor level for every additional height of 3 m or part there of. 682 13.36 Providing and fixing broken glass in cement mortar 1.3 including cost of mortar, over compound walls. 683 13.37 Providing and fixing writing board green writing with chalk (regular modified polyster coated steel surface). of sizes. 13.37.1 size 1200mmx1800mm 13.37.2 size 1200mmx2400mm 13.37.3 size 1200mmx3000mm 684 13.38 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 685 13.39 Providing and applying plaster of paris punning of 10 mm average thickness over plastered surface to prepare the surface even and smooth complete. 686 13.40 Extra for lining out plaster to imitate stone or concrete blocks walling. 687 13.41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required. 688 13.42 Providing and applying special putty in two coats based materials varnish, Belgium chalk, turpentine oil, white paint, safeda including sand papering for making the surface smooth for applying any or vinyl paints including all cost of material and labouretc complete. 689 13.43 White washing with lime to give an even shade: New work (three or more coats) 690 13.44 Colour washing such as green, blue or buff to give an even shade: New work (two or more coats) with a base coat of white washing with lime. 691 13.45 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 grams/ltr of approved manufacturer, of required shade and colour complete, as per manufacturers specification. Two or more coat on new work. 692 13.46 Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work 693 13.47 Distempering by any mechanical or manual means with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.47.1 One coat. 13.47.2 Two coats. 694 13.48 Wall painting by any mechanical or manual means with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.48.1 One coat. 13.48.2 Two coats. 695 13.49 Wall painting by any mechanical or manual means with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade. 696 13.50 Finishing walls by any mechanical or manual means with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm). 697 13.51 Finishing walls by only mechanical or manual means with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. 698 13.52 Finishing walls by any mechanical or manual means with Acrylic Smooth exterior paint (Economy Exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface 699 13.53 Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface) 700 13.54 Finishing walls by any mechanical or manual means with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.54.1 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 13.54.2 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture. 13.54.3 Two or more coats applied on walls @ 1.25 ltr/10 sqm. Over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm. 701 13.55 Painting with silicon and acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces: 13.55.1 One coat 13.55.2 Two coats 702 13.56 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. 13.56.1 On steel work 13.56.2 On concrete work 703 13.57 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. 704 13.58 Applying a coat of mordant solution on G.S. sheet : 13.58.1 With a solution of 38 gms of copper acetate in a litre of soft water 13.58.2 With a solution made of 13 gms of hydrochloric acid in a solution of 13 gms each of copper chloride, copper nitrate and ammonium chloride dissolved in a litre of soft water. 705 13.59 Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint approved brand and manufacture over and including a priming of ready mixed zinc chromate yellow primer on new work : 13.59.1 75 mm diameter pipes 13.59.2 100 mm diameter pipes 13.59.3 150 mm diameter pipes 706 13.60 Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 13.60.1 75 mm diameter pipes 13.60.2 100 mm diameter pipes 13.60.3 150 mm diameter pipes 707 13.61 Painting with oil type wood preservative of approved brand and manufacture: New work (two or more coats) 708 13.62 Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. 709 13.63 Coal tarring two coats on new work using 0.16 and 0.12 litre coal tar per sqm in the first coat and second coat respectively. 710 13.64 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 711 13.65 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 712 13.66 Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 13.66.1 One coat. 13.66.2 Two coats. 713 13.67 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 13.67.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. 13.67.2 With ready mixed red oxide zinc chromatic on steel/ iron works having VOC content less than 250 grams/litre. 13.67.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. 714 13.68 Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work. 715 13.69 Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work. 716 13.70 Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 717 13.71 Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work 718 13.72 Varnishing with varnish of approved brand and manufacture: 13.72.1 Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. 13.72.2 Two or more coats glue sizing with spar varnish or an under coat of flatting varnish. 719 13.73 French spirit polishing: Two or more coats on new works including a coat of wood filler. 720 13.74 Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work. 721 13.75 Lacqer polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying lacqer polish with air compressor. Two or more coats on new works including a coat of wood filler. 722 13.76 Mealamine polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying mealamine polish with air compressor. Two or more coats on new works including a coat of wood filler. 723 13.77 Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture. 724 13.78 Lettering with black Japan paint of approved brand and manufacture. 725 13.79 Providing and applying flakes textured homogeneous wall finishing system consisting of a two component system of dry flakes (9.5kgs per/pack) made of a special grade of heat treated China clay with rigid homopolymer coated with fade resistant pigments and a 100% acrylic polymer Bonding agent (5kgs/pack) applied thickness of the coating being between 0.8-1.2mm, to be applied in single coat, on a cured, smooth level plaster surface without keying, as per the shades/ combinations approved, as per manufacturers directions for usage, to be applied by approved applicator of manufacturer, as per direction/ supervision of the engineers-in-charge inclusive of one coat of primer on the base at all heights etc all complete. 726 13.80 Providing and applying Granules homogeneous wall finishing system consisting of a two component system of dry granules (25 kgs/pack) made of 92% silica particles coated with fade resistant pigments and a 100% acrylic Polymer Bonding agent (5 kgs/pack) with the applied thickness of coating as required to be applied in single coat, on a cured. Smooth level plaster surface without keying as per the shades/combinations approved. As per the manufacturers directions for usage, to be applied by approved applicator of manufacturer, as per the directions/supervision of engineers in charge, all complete inclusive of primer on the base. 13.80.1 0.8-1.2mm thickness 13.80.2 2.0-2.5mm thickness 727 13.81 Providing and Applying Roto Wall finishing system being a dispersion of inorganic fillers, calcite, pure silica, quartz and broad spectrum fungicides stabilized by an acrylic co-polymer, to be applied by means of customized trowels (one for incorporating material on base and spreading and other for finishing) in single coat with a coating thickness of 2.0-2-2.5mm on a cured smooth level plaster without keying, by the approved applicator of manufacturer, of the approved shade as per directions for usage all inclusive including primer coat on the base. 728 13.82 Providing and plastering over AAC masonary wall with polymer modified cement based readymix factory controlled mortar with self curing, eco- friendly, wet premix in a mechanical mixer in thickness as specified below, and covering area of 2.04 kg per sqm/mm thickness. The Bulk density of ready mix plaster may vary from 1300 to 1600 Kg/cum, Water powder ratio (as per manufacture’s direction) may vary from 18-22 % by weight or as specified by the manufacturer and compressive strength may vary from 8-9 Mpa. 13.82.1 6 mm thick plaster for internal walls 13.82.2 8 mm thick plaster for external walls exposed to weather. 729 13.83 Providing and fixing including Designing and UV printing on aluminium composite material (ACM) sheet in different sizes with 720DPI (Dot per inch) 13.83.1 ACP sheet 2mm thick 13.83.2 ACP sheet 3mm thick 13.83.3 ACP sheet 4mm thick 730 13.84 Providing and fixing including designing and UV printing on pvc foam sheet of different size with 720 DPI (Dot per inch) 13.84.1 PVC foam sheet 3.0 mm thick 13.84.2 PVC foam sheet 5.0 mm thick 13.84.3 PVC foam sheet 8.0 mm thick 731 13.85 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 732 13.86 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board (XPS) of required size over outer wall surface, complying with ASTM C 578 - type VI, having thermal conductivity of 0.0289 W/mK as per ASTM and Fire retardant property as per DIN 4102, Part 1. XPS insulation of thickness 50mm shall be placed over brushed, algae free and levelled external wall by connecting the ship-laps joints and fixed by the washer and Self-Tapping Screw of suitable length at each corner and at distance 75mm from the edge and bitumen shall be applied over the joints and G.I. Expanded Mesh (Barfi Jali) shall be fixed over XPS board by a Self- Tapping Screw of suitable length at the centre of the board and 15mm PCC shall be applied over the board (paint of suitable choice can be used), all as per the directions of Engineer-in-Charge. 733 13.87 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorption < 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge. 734 13.88 Painting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats) 735 13.89 Scrapping/sand papering of existing surface with the help of mechanized sanding machine (having mechanical vaccum machine with bag for dust collection to make surface even and smooth) as per direction of Engineer-in- Charge. 736 13.90 Providing and applying 1 coat of Triple booster primer-resist dampness, efflorescence, alkali & at the same time improve top coat coverage by 15-20% @1.0 lt/ 10 sqm, which confirms certfication of IS 109/1968. It can be applied by Brush/ Spray Machine and the work shall be carried out as per secification& the direction of the Engineer-in-Charge. 737 13.91 Finishing walls with water based anti- germ paint of with VOC < 50 g/l, that kills disease causing germs, teflon based washability and Anti fungal properties in two or more coats @ 1.08 ltr / 10 sqm over priming coat of interior primer applied @ 1.08 ltr / 10 sqm of required shade including removing of all dust complete as per direction of Engineer- in-Charge and submission of challans of materials on enquiry. 738 13.92 Providing and applying in two coats of 250 micron thick each layer of epoxy coating on prepared surface (cost includes preparing the plastered surface smooth ready to receive epoxy coating) for operation theater walls in desired colour as per direction of Engineer-in-Charge. 739 14.1 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand). 740 14.2 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 meters lead : 14.2.1 Door chowkhats 14.2.2 Window chowkhats 14.2.3 Clerestory window chowkhats 741 14.3 Fixing chowkhat in existing opening in brick / RCC wall with dash fasteners/ chemical fastener of appropriate size (3nos on each vertical member of door chowkhat and 2 nos. on each vertical member of window chowkhats) including cost of dash fasteners/ chemical fastener. 742 14.4 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/ rubbish as directed by Engineer- in-charge. For door/ window/ clerestory window. 743 14.5 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of thickness 4 mm 14.5.2 Float glass panes of thickness 5.5 mm 744 14.6 Renewing glass panes with now wooden fillets wherever necessary: 14.6.1 Float glass panes of thickness 4 mm 14.6.2 Float glass panes of thickness 5.5 mm 745 14.7 Renewing glass panes and refixing existing wooden fillets: 14.7.1 Float glass panes of thickness 4 mm 14.7.2 Float glass panes of thickness 5.5 mm 746 14.8 Supplying and fixing new wooden fillets wherever necessary: 14.8.1 2nd class teak wood fillets 14.8.2 Haldu/Bija/Kail wood fillets. 747 14.9 Renewal of old putty of glass panes (length). 748 14.10 Refixing old glass panes with putty and nails. 749 14.11 Fixing old glass panes with wooden fillets (excluding cost of fillets). 750 14.12 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 751 14.13 Replacing sand stone slabs in roofing laid in cement mortar 1:4 (1 cement : 4 sand) including necessary repairs and cement pointing with same mortar complete including disposal of rubbish to dumping ground within 50 metres of lead : 14.13.1 Red/ white sand stone slabs 30 to 50 mm thick. 752 14.14 Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead : 14.14.1 Sal wood battens. 753 14.15 Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead : 14.15.1 Not exceeding 4.00 metres in length. 14.15.1.1 Sal wood beams 14.15.1.2 Haldu/Bija/Kail wood fillets. 14.15.2 Above 4.00 metres and upto 5.00 metres length. 14.15.2.1 Sal wood beams 14.15.2.2 Haldu/Bija/Kail wood fillets. 754 14.16 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground within 50 metres lead. 755 14.17 Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. 756 14.18 Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand and manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand. 757 14.19 Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. 758 14.20 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. 14.20.1 Wheel 50 mm dia. and below. 14.20.2 Wheel above 50 mm dia. 759 14.21 Providing and fixing 25 mm thick shutters for cupboard etc. : 14.21.1 Panelled or panelled and glazed shutters : 14.21.1.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.1.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.2 Glazed shutters : 14.21.2.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.2.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 760 14.22 Providing and fixing plain jaffri door and window shutters including bright or/and black enamelled M.S. butt hinges with necessary screws 35x10mm laths placed 35mm apart (frames to be paid separately) including fixing 50x12mm beading complete with: 14.22.1 Second class teak wood. 14.22.2 Hard wood, finger jointed 761 14.23 Providing and fixing curtain rods of 1.25mm thick brass plates with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 14.23.1 20 mm diameter. 14.23.2 25 mm diameter. 762 14.24 Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. 763 14.25 Providing joists (karries) including hoisting fixing in position and applying wood preservative on unexposed surface etc. complete with: 14.25.1 Sal wood. 14.25.2 Haldu/Bija/Kail wood. 764 14.26 White washing with lime old work to give an even shade : 14.26.1 two or more coats 14.26.2 one or more coats 765 14.27 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 766 14.28 Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to give an even shade. 767 14.29 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: Old work (one or more coats). 768 14.30 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 769 14.31 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Old work (one or more coats). 770 14.32 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work : 14.32.1 75 mm diameter pipes 14.32.2 100 mm diameter pipes 14.32.3 150 mm diameter pipes 771 14.33 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with aluminium paint of approved brand and manufacture on old work : 14.33.1 75 mm diameter pipes 14.33.2 100 mm diameter pipes 14.33.3 150 mm diameter pipes 772 14.34 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 14.34.1 75 mm diameter pipes 14.34.2 100 mm diameter pipes 14.34.3 150 mm diameter pipes 773 14.35 Painting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats) 774 14.36 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work. 775 14.37 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work. 776 14.38 Painting with aluminium paint of approved brand and manufacture to give an even shade: One or more coats on old work. 777 14.39 Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work. 778 14.40 Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: One or more coats on old work. 779 14.41 French spirit polishing: One or more coats on old work. 780 14.42 Mealamine polishing on wood work by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying Mealamine polish with air compressor. One or more coats on old work. 781 14.43 Lacquer polishing on wood work by preparing the surface applying putty base course. prepare the surface smooth by sand papering and then applying Lacquer polish with air compressor 14.43.1 One or more coats on old work. 782 14.44 Polishing on wood work with readymade wax polish of approved brand and manufacture : 14.44.1 Old work 783 14.45 Re-lettering with black Japan paint of approved brand and manufacture. 784 14.46 Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. 785 14.47 Providing and fixing C.P. brass chain and rubber plug complete for sink or wash basin : 14.47.1 32 mm dia 14.47.2 40 mm dia 786 14.48 Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete. As per manufacturers specification. One or more coats on old work. 787 14.49 Finishing walls with water proofing cement paint of required shade : 14.49.1 Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 liters/10 sqm complete including cost of Priming coat. 14.49.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. 788 14.50 Finishing walls with textured exterior paint of required shade : 14.50.1 Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. 14.50.2 Old work (One or more coats) applied @ 1.82 ltr/10 sqm. 789 14.51 Finishing walls with Acrylic Smooth exterior paint of required shade : 14.51.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). 14.51.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm). 790 14.52 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 14.52.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. 14.52.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm). 791 14.53 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 14.53.1 One or more coats applied on walls @ 0.85 ltr/10 sqm. 14.53.2 Painting wood work with Deluxe Multi Surface Paint of required shade. One or more coat applied @0.70 ltr/10 sqm 14.53.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. One or more coat applied @0.70 ltr/10 sqm. 792 14.54 Varnishing with varnish of approved brand and manufacture: 14.54.1 One or more coats with copal varnish. 14.54.2 One or more coats with spar varnish. 793 14.55 Melamine polishing on wood work (one or more coat). Old work 794 14.56 Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work. 795 14.57 Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade. One or more coat on old work. 796 14.58 40 mm thick stone flooring over 20 mm (average)thick base of cement mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1 cement : 2 sand) with an admixture of pigment to match the shade of stone. Red sand stone / White sand stone) stone to be supplied by the department. 14.58.1 Rough chiseled dressed stone 14.58.2 Fine dressed stone 797 14.59 Coursed rubble masonry (second sort) with hard stone in Cement mortar 1:6 (1 cement : 6 sand) (Stone shall be supplied by the department) 798 14.60 Laying old cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50mm thick compacted bed of sand, filling the joints with sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). 799 14.61 Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand) including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5mm) including making drainage opening wherever required etc. complete as per direction of Engineer-in- charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost). 800 14.62 Colour washing with lime to give an even shade: 14.62.1 (one or more coats) 14.62.2 (two or more coats) 801 14.63 Conducting adequate nos. of scanning to detect the steel reinforcement in existing RCC elements by using ground/ Wall penetrating radar system to avoid the cutting of Main bars during drilling for inserting bolts etc. complete. 802 14.64 Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure as Instructed by Engineer-in-Charge. 803 14.70 Rebaring of TMT bars by drilling hole & embedding bars of different diameter using epoxy grouting compound including all tools and tackles complete. 14.70.1 8 mm dia bar 10 mm dia hole 14.70.2 10 mm dia bar 12 mm dia hole 14.70.3 12 mm dia bar 16 mm dia hole 14.70.4 16 mm dia bar 20 mm dia hole 14.70.5 20 mm dia bar 25 mm dia hole 14.70.6 25 mm dia bar 32 mm dia hole 14.70.7 32 mm dia bar 40 mm dia hole 804 14.71 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 14.71.1 125x70x4 mm (ordinary type) 14.71.2 100x70x4 mm (ordinary type) 14.71.3 75x65x4 mm (heavy type) 14.71.4 75x40x2.5 mm (ordinary type) 14.71.5 50x40x2.5 mm (ordinary type) 805 14.72 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete. 806 14.73 Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. 807 14.74 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of f tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in- Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 808 14.75 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer- incharge. 809 14.77 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 14.77.1 Bars upto 12 mm diameter 14.77.2 Bars above 12 mm diameter 810 14.78 Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. 14.78.1 Upto and including 12mm dia 811 14.83 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) 14.83.1 Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work 14.83.2 Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work. 14.83.3 Epoxy injection grout in concrete/RCC work of approved make 812 14.85 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 813 14.88 Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of L shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-incharge. 814 15.1 Demolishing lime concrete manually/by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-Charge. 815 15.2 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in- Charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). 816 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. 817 15.4 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. work (Payment shall be made on the cross sectional area of R.C.C. work) as per direction of Engineer-in- Charge. 818 15.5 Extra for scrapping, cleaning and straightening reinforcement from R.C.C. work. 819 15.6 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. 820 15.6.1 In lime mortar with old mughal bricks. 15.6.2 In lime mortar. 15.6.3 In cement mortar. 821 15.7 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) : 15.7.1 From brick work in lime mortar. 15.7.2 From brick work in cement mortar. 822 15.8 Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge: 15.8.1 In lime mortar. 15.8.2 In cement mortar. 823 15.9 Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge: 15.9.1 In lime mortar. 15.9.2 In cement mortar. 824 15.10 Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured) : 15.10.1 In lime mortar. 15.10.2 In cement mortar. 825 15.11 Dismantling tile/ Kota stone/ Marble / Granite work in floors/walls and roofs laid in cement mortar including stacking material within 50 metres lead. 15.11.1 For thickness of tiles 10 mm to 25 mm. 15.11.2 For thickness of tiles above 25 mm and upto 40 mm. 826 15.12 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 827 15.13 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. 828 15.14 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.14.1 Of area 3 sq. metres and below. 15.14.2 Of area beyond 3 sq. metres. 829 15.15 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: 15.15.1 Of area 3 sq. metres and below. 15.15.2 Of area beyond 3 sq. metres. 830 15.16 Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking the material within 50 metres lead: 15.16.1 Of sectional area below 40 square centimetres. 15.16.2 Of sectional area 40 square centimetres and above. 831 15.17 Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one metre or part thereof beyond 10 metres : 15.17.1 Of sectional area below 40 square centimetres. 15.17.2 Of sectional area 40 square centimetres and above. 832 15.18 Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one metre or part thereof beyond 5 metres : 15.18.2 Of sectional area below 40 square centimetres. 15.18.1 Of sectional area 40 square centimetres and above. 833 15.19 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: 15.19.1 R.S. Joists 15.19.2 Channels, angles, tees and flats 834 15.20 Dismantling steel work in built up sections with span upto 10 meter and hieght 5 meter in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. 835 15.21 Dismantling steel work manually/ by mechanical means in built up sections with span upto 10 meter and hieght 5 meter without dismembering and stacking within 50 metres lead as per direction of Engineer-in-Charge. 836 15.22 Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres 837 15.23 Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one metre or part thereof beyond 5 metres. 838 15.24 Extra for marking of structural steel work required to be re- erected. 839 15.25 Removal of old Tarfelt i/c disposal as directed by Engineer in charge. 840 15.26 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 841 15.27 Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of: 15.27.1 G.S. Sheet 15.27.2 Asbestos/ Non asbestors sheet 842 15.28 Dismantling stone slab roofing over wooden karries or R.C.C. battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 843 15.29 Dismantling tiled roofing with battens boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 844 15.30 Dismantling wooden ballies in posts and struts including stacking within 50 metres lead. 845 15.31 Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of : 15.31.1 T’ or ‘L’ iron or pipe 15.31.2 R.C.C. 846 15.32 Cutting ballies or wooden posts of fencing at the point of projection above the concrete or ground and stacking the same within 50 metres lead. 847 15.33 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. 848 15.34 Dismantling wooden trellis work excluding frames but including stacking the serviceable material within 50 metres lead. 849 15.35 Dismantling expanded metal or I.R.C. fabrics with necessary battens and beading including stacking the serviceable material within 50 metres lead. 850 15.36 Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : 15.36.1 Upto 10 mm thick 15.36.2 Thickness above 10 mm upto 25 mm 15.36.3 Thickness above 25 mm upto 40 mm 851 15.37 Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead: 15.37.1 Thickness upto 40 mm 15.37.2 Thickness above 40 mm upto 75 mm 852 15.38 Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. 853 15.39 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 15.39.1 75 to 80 mm dia pipe. 15.39.2 100 mm dia pipe 15.39.3 150 mm dia pipe 854 15.40 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-Charge : 15.40.1 15 mm to 40 mm nominal bore 15.40.2 Above 40 mm nominal bore 855 15.41 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanical means, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 metre lead as per direction of Engineer-in-Charge: 15.41.1 Upto 150 mm diameter 15.41.2 Above 150 mm dia upto 300 mm dia. 15.41.3 Above 300 mm diameter 856 15.42 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in- Charge. 857 15.43 Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in- Charge. 858 15.44 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 859 15.45 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 860 15.46 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 15.46.1 Upto 150 mm diameter 15.46.2 Above 150 mm diameter 861 15.47 Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. 862 15.48 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 863 15.49 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-Charge. 864 15.50 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps: 15.50.1 100 mm diameter 15.50.2 150 mm diameter 15.50.3 200 mm diameter 15.50.4 250 mm diameter 15.50.5 300 mm diameter 15.50.6 350 mm diameter 15.50.7 400 mm diameter 15.50.8 440 mm diameter 865 15.51 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead : 15.51.1 Rectangular manhole 90x80 cm and 45 cm deep 15.51.2 Rectangular manhole 120x90 cm and 90 cm deep. 15.51.3 Rectangular arch type manhole 140x90cm and 2.45m deep. 15.51.4 Circular manhole 122 cm diameter and 1.68 m deep 866 15.52 Extra for depth of manholes dismantled: 15.52.1 Rectangular manhole 90x80 cm and beyond 45 cm depth. 15.52.2 Rectangular manhole 120x90 cm and beyond 90 cm depth. 15.52.3 Rectangular arch type manhole 140x90 cm and beyond 2.45m deep (upto 4.25 m depth). 15.52.4 Circular manhole 122 cm diameter and beyond 1.68 m deep (upto 2.29 m depth). 867 15.53 Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground and stacking of serviceable material within 50 metre lead as per direction of Engineer-in- Charge. 868 15.54 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : 869 15.55 Demolishing mud phaska in terracing and disposal of material within 50 metres lead. 870 15.56 Dismantling jack arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 871 15.57 Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. 872 15.58 Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge : 15.58.1 Water bound macadam road 15.58.2 Bituminous road 873 15.59 Dismantling steel cylinder R.C. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metres lead as per direction of Engineer-in-charge : 15.59.1 Up to 600 mm diameter 15.59.2 Above 600 mm diameter 874 15.60 Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanical means and stacking the pipes within 50 metres lead as per direction of Engineer-in-charge 15.60.1 Up to 150 mm diameter 15.60.2 Above 150 mm diameter 875 15.61 Dismantling of R.C.C. spun vent shaft including excavating the cement concrete pit completely, taking out the shaft, refilling the excavated gap, stacking the useful materials near the site and disposal of unserviceable materials within 50 metres lead. 876 15.62 Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead: 15.62.1 120 x 120 cm (outside to outside) 15.62.2 210 x 120 cm (outside to outside) 877 15.63 Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in- charge. 878 15.64 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 879 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. 17.1.2 Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests. 880 17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid 17.2.2 W.C. pan with ISI marked black solid plastic seat and lid 17.2.3 Providing and fixing AISI-304 (18/8) European type WC instead of white vitreous china pedestal type water closet. 881 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. 17.3.2 W.C. pan with ISI marked black solid plastic seat and lid. 882 17.4 Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat and lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend, 20mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required White vitreous china dual purpose WC pan with white solid plastic seat and lid with 10 liter low level flushing cistern i/c C.P. flush bend. 883 17.5 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 884 17.6 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.6.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern. 17.6.2 Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern. 17.6.3 Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern. 17.6.4 Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern. 885 17.7 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever require 17.7.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. 17.7.2 Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern. 17.7.3 Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern. 17.7.4 Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern. 886 17.8 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete including painting of fittings and cutting and making good the walls and floors etc. wherever required : 17.8.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern. 17.8.2 Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern. 17.8.3 Range of three squatting plates with 10 litre P.V.C. automatic flushing cistern. 17.8.4 Range of four squatting plates with 10 litre P.V.C. automatic flushing cistern. 887 17.9 Providing and fixing white vitreous china water less urinal of size 600x330x315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. 888 17.10 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-Charge. 889 17.11 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 17.11.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 17.11.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. 17.11.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. 17.11.4 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. 17.11.5 White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap. 17.11.6 White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap. 17.11.7 White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap. 17.11.8 White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated lever ISI marked. 17.11.9 White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI marked. 17.11.10 Oval shape wash basin over counter /under counter with 15 mm C.P brass pillar tap (Counter to be paid sepratly). 17.11.11 Stainless Steel AISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap 17.11.12 Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap. 890 17.12 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 891 17.13 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm. 892 17.14 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 17.14.1 Kitchen sink with drain board 17.14.1.1 510x1040 mm bowl depth 250mm. 17.14.1.2 510x1040 mm bowl depth 225mm. 17.14.1.3 510x1040 mm bowl depth 200mm. 17.14.1.4 510x1040 mm bowl depth 178mm. 17.14.2 Kitchen sink without drain board 17.14.2.1 610x510 mm bowl depth 200 mm. 17.14.2.2 610x460 mm bowl depth 200 mm. 17.14.2.3 470x420 mm bowl depth 178 mm. 893 17.15 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required : 17.15.1 Size450x300x150mm 17.15.2 Size600x450x200mm 894 17.16 Providing and fixing White glazed fire clay draining board of size 600x450x25mm with C.I. brackets including painting of brackets, cutting and making good the walls wherever required. 895 17.17 Providing and fixing white vitreous china water closet squatting pan (Indian type) 17.17.1 Long pattern W.C. pan of size 580 mm 17.17.2 Orissa pattern W.C. pan of size 580x440 mm 896 17.18 Extra for using coloured W.C. pan instead of white W.C. pan Orissa pattern W.C. pan 580x440 mm 897 17.19 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. 898 17.20 Extra for using coloured pedestal type W.C pan (European type) with low level cistern of same colour instead of white vitreous china W.C pan and cistern. 899 17.21 Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet: 17.21.1 250x130x30 mm 17.21.2 250x125x25 mm 900 17.22 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete. 10 litre capacity 17.22.1 White 17.22.2 coloured 901 17.23 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.10 litre (full flush capacity) 17.23.1 White 17.23.2 Coloured 902 17.24 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : 17.24.1 White 17.24.2 Black 17.24.3 Coloured (other than black and white) 903 17.25 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. 904 17.26 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm or 340x410x265mm sizes respectively. 905 17.27 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm. 906 17.28 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 907 17.29 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : 17.29.1 Flat back wash basin of size 630x450mm. 17.29.2 Flat back wash basin of size 550x400mm. 17.29.3 Angle back wash basin of size 600x480mm. 17.29.4 Angle back wash basin of size 400x400mm. 17.29.5 Flat back wash basin of size 450x300mm. 17.29.6 Surgeon type wash basin of size 660x460mm. 908 17.30 Providing and fixing kitchen sink including making all connections excluding cost of fittings. White glazed fire clay sink of size 600x450x250mm. 909 17.31 Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings: 17.31.1 Size 450x300x150 mm. 17.31.2 Size 600x450x200 mm. 910 17.32 Providing and fixing soil, waste and vent pipes: 17.32.1 Sand cast iron socket and spigot (S&S) pipe as per IS: 1729 17.32.1.1 75 mm dia with wall thickness of 5 mm 17.32.1.2 100 mm dia with wall thickness of 5 mm 17.32.2 Spun cast iron socket and spigot (S&S) pipe as per IS: 3989 17.32.2.1 75 mm dia with wall thickness of 3.5 mm 17.32.2.2 100 mm dia with wall thickness of 4 mm 17.32.2.3 150mm dia with wall thickness of 5mm 17.32.3 Hubless Centrifugally cast (spun) iron pipe epoxy coated in side & out side including complete coupling assembly (EPDM rubber gasket stainless steel claim and external metallic/ protective shield as per IS:15905) 17.32.3.1 75 mm dia with wall thickness of 3.5 mm 17.32.3.2 100 mm dia with wall thickness of 3.5mm 17.32.3.3 150mm dia with wall thickness of 4 mm 911 17.33 Providing and filling the joints with spun yarn cement slurry and cement mortar 1:2 ( 1 cement : 2 sand) in S.C.I./ C.I. Pipes : 17.33.1 75 mm dia pipe 17.33.2 100 mm dia pipe 912 17.34 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 17.34.1 For 75 mm dia pipe 17.34.2 For 100 mm dia pipe 17.34.3 For 150 mm dia pipe 913 17.35 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.35.1 150 mm dia 17.35.1.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.35.1.2 Spun cast iron as per IS – 3989 minimum wall thickness 5 mm 17.35.1.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3.5 mm 17.35.2 100 mm dia 17.35.2.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.35.2.2 Spun cast iron as per IS – 3989 minimum wall thickness 4 mm 17.35.2.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 17.35.3 75 mm dia 17.35.3.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5 mm 17.35.3.2 Spun cast iron as per IS – 3989 minimum wall thickness 3.5 mm 17.35.3.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 914 17.36 Providing and fixing plain bend of required degree. 17.36.1 150 mm dia 17.36.1.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.1.2 Spun cast iron as per IS – 3989 minimum wall thickness 5 mm 17.36.1.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3.5 mm 17.36.2 100 mm dia 17.36.2.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.2.2 Spun cast iron as per IS – 3989 minimum wall thickness 4 mm 17.36.2.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 17.36.3 75 mm dia 17.36.3.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.3.2 Spun cast iron as per IS – 3989 minimum wall thickness 3.5 mm 17.36.3.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 915 17.37 Providing and fixing heel rest sanitary bend 17.37.1 100 mm dia 17.37.1.1 Sand cast iron as per IS - 1729 17.37.1.2 Spun cast iron as per IS - 3989 17.37.2 75 mm dia 17.37.2.1 Sand cast iron as per IS - 1729 17.37.2.2 Spun cast iron as per IS - 3989 916 17.38 Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 17.38.1.1 150X150X150X150 17.38.1.2 Sand cast iron as per IS - 3989 17.38.2 100x100x100x100mm 17.38.2.1 Sand cast iron as per IS - 1729 17.38.2.2 Spun cast iron as per IS - 3989 17.38.3 75x75x75x75mm 17.38.3.1 Sand cast iron as per IS - 1729 17.38.3.2 Spun cast iron as per IS - 3989 917 17.39 Providing and fixing double equal plain junction of required degree. 17.39.1 150X150X150X150 mm 17.39.1.1 Sand cast iron as per IS - 3989 17.39.2 100x100x100x100mm 17.39.2.1 Sand cast iron as per IS – 1729 17.39.2.2 Spun cast iron as per IS – 3989 17.39.2.3 Hubless cast(spun) iron as per IS- 15905 17.39.3 75x75x75x75 mm 17.39.3.1 Sand cast iron as per IS – 1729 17.39.3.2 Spun cast iron as per IS – 3989 17.39.3.3 Hubless cast(spun) iron as per IS- 15905 918 17.40 Providing and fixing single equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.40.1 150X150X150 mm 17.40.1.1 Spun cast iron as per IS - 3989 17.40.2 100x100x100 mm 17.40.2.1 Sand cast iron as per IS - 1729 17.40.2.2 Spun cast iron as per IS - 3989 17.40.3 75x75x75 mm 17.40.3.1 Sand cast iron as per IS - 1729 17.40.3.2 Spun cast iron as per IS - 3989 919 17.41 Providing and fixing single equal plain junction of required degree : 17.41.1 150X150X150 mm 17.41.1.1 Spun cast iron as per IS - 3989 17.41.2 100x100x100 mm 17.41.2.1 Sand cast iron as per IS – 1729 17.41.2.2 Spun cast iron as per IS – 3989 17.41.2.3 Hubless cast(spun) iron as per IS- 15905 17.41.3 75x75x75 mm 17.41.3.1 Sand cast iron as per IS – 1729 17.41.3.2 Spun cast iron as per IS – 3989 17.41.3.3 Hubless cast(spun) iron as per IS- 15905 920 17.42 Providing and fixing double unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x75x75 mm 17.42.1 Sand cast iron as per IS - 1729 17.42.2 Spun cast iron as per IS - 3989 921 17.43 Providing and fixing double unequal plain junction of required degree: 100x100x75x75 mm 17.43.1.1 Sand cast iron as per IS – 1729 17.43.1.2 Spun cast iron as per IS – 3989 17.43.1.3 Hubless cast(spun) iron as per IS- 15905 922 17.44 Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100x100x75 mm 17.44.1 Sand cast iron as per IS - 1729 17.44.2 Spun cast iron as per IS - 3989 923 17.45 Providing and fixing single unequal plain junction of required degree : 100x100x75 mm 17.45.1 Sand cast iron as per IS – 1729 17.45.2 Spun cast iron as per IS – 3989 17.45.3 Hubless cast(spun) iron as per IS- 15905 924 17.46 Providing and fixing double equal plain invert branch of required degree: 17.46.1 100x100x100x100 mm 17.46.1.1 Sand cast iron as per IS - 1729 17.46.1.2 Sand cast iron as per IS - 3989 17.46.1.3 Hubless cast(spun) iron as per IS- 15905 17.46.2 75x75x75x75 mm 17.46.2.1 Sand cast iron as per IS - 1729 17.46.2.2 Spun cast iron as per IS - 3989 925 17.47 Providing and fixing single equal plain invert branch of required degree: 17.47.1 100x100x100 mm 17.47.1.1 Sand cast iron as per IS - 1729 17.47.1.2 Sand cast iron as per IS - 3989 17.47.1.3 Hubless cast(spun) iron as per IS- 15905 17.47.2 75x75x75 mm 17.47.2.1 Sand cast iron as per IS - 1729 17.47.2.2 Sand cast iron as per IS - 3989 17.47.2.3 Hubless cast(spun) iron as per IS- 15905 926 17.48 Providing and fixing double unequal invert branch of required degree : 100x100x75x75 mm 17.48.1 Sand cast iron as per IS - 1729 17.48.2 Spun cast iron as per IS - 3989 927 17.49 Providing and fixing single unequal plain invert branch of required degree : 100x100x75 mm 17.49.1 Sand cast iron as per IS - 1729 17.49.2 Spun cast iron as per IS - 3989 17.49.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 928 17.50 Providing and fixing sand cast iron S&S off sets as per IS: 1729 17.50.1 76 mm off sets 17.50.1.1 With 75 mm dia pipe 17.50.1.2 With 100 mm dia pipe 17.50.2 114 mm off sets 17.50.2.1 With 75 mm dia pipe 17.50.2.2 With 100 mm dia pipe 17.50.3 152 mm off sets 17.50.3.1 With 75 mm dia pipe 17.50.3.2 With 100 mm dia pipe 929 17.51 Providing and fixing sand cast iron S&S off sets as per IS: 3989. 17.51.1 75 mm off sets 17.51.1.1 With 75 mm dia pipe 17.51.1.2 With 100 mm dia pipe 17.51.1.3 With 150 mm dia pipe 17.51.2 150 mm off sets 17.51.2.1 With 75 mm dia pipe 17.51.2.2 With 100 mm dia pipe 17.51.2.3 With 150 mm dia pipe 930 17.52 Providing and fixing door piece, insertion rubber washer 3mm thick, bolts and nuts complete : 17.52.1 100 mm 17.52.1.1 Sand cast iron as per IS - 1729 17.52.1.2 Spun cast iron as per IS - 3989 17.52.2 75 mm 17.52.2.1 Sand cast iron as per IS - 1729 17.52.2.2 Spun cast iron as per IS - 3989 931 17.53 Providing and fixing terminal guard: 17.53.1 150mm 17.53.1.1 Sand cast iron as per IS - 1729 17.53.1.2 Spun cast iron as per IS - 3989 17.53.1.3 Hubless cast(spun) iron as per IS- 15905 17.53.2 100 mm 17.53.2.1 Sand cast iron as per IS - 1729 17.53.2.2 Spun cast iron as per IS - 3989 17.35.2.3 Hubless cast(spun) iron as per IS-15905 17.53.3 75 mm 17.53.3.1 Sand cast iron as per IS - 1729 17.53.3.2 Spun cast iron as per IS - 3989 17.53.3.3 Hubless cast(spun) iron as per IS- 15905 932 17.54 Providing and fixing collar: 17.54.1 100 mm 17.54.1.1 Sand cast iron S & S as per IS - 1729 17.54.1.2 Sand cast iron S & S as per IS - 3989 17.54.2 75 mm 17.54.2.1 Sand cast iron S & S as per IS - 1729 17.54.2.2 Sand cast iron S & S as per IS- 3989 933 17.55 Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter: 17.55.1 150mm 17.55.2 100 mm 17.55.3 75 mm 934 17.56 Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 17.56.1 100 mm dia 17.56.2 75 mm dia 935 17.57 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 17.57.1 100 mm inlet and 100 mm outlet 17.57.1.1 Spun cast iron S & S as per IS: 3989. 17.57.1.2 Sand Cast iron S & S as per IS: 1729. 17.57.1.3 Hubless cast(spun) iron as per IS-15905 17.57.2 100 mm inlet and 75 mm outlet 17.57.2.1 Sand cast iron S & S as per IS - 3989 17.57.2.2 Spun Cast iron S & S as per IS- 1729. 17.57.2.3 Hubless cast(spun) iron as per IS- 15905 936 17.58 Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) 17.58.1 75 mm diameter 17.58.2 110 mm diameter 937 17.59 Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.1 Coupler 17.59.1.1 75 mm 17.59.1.2 110 mm 17.59.2 Single pushfit Coupler 17.59.2.1 75 mm 17.59.2.2 110 mm 17.59.3 Single tee with door 17.59.3.1 75x75x75 mm 17.59.3.2 110x110x110 mm 17.59.4 Single tee without door 17.59.4.1 75x75x75 mm 17.59.4.2 110x110x110 mm 17.59.5 Bend 87.50 17.59.5.1 75 mm bend 17.59.5.2 110 mm bend 938 17.60 Providing and fixing Unplasticised - PVC pipe clips of approved design to Unplasticised - PVC soil and waste pipes by means of bombay nail of required length including and making good the wall etc. complete. 17.60.1 75 mm 17.60.2 110 mm 939 17.61 Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet 940 17.62 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5mm flat of specified shape, projecting 75mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners including drilling necessary holes in brick wall/ CC/ RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30mm x1.6mm galvanised M.S. flats of specified shape and of total length 420mm and shall be fixed with M.S. nuts, bolts, and washers of size 25x6mm, one bolts on each side of the pipe. 17.62.1 Total bracket length 580mm of approved shape and design (for single, 100mm dia pipe). 17.62.2 Total bracket length 810mm of approved shape and design (for two, 100mm dia pipes). 17.62.3 Total bracket length 1040mm of approved shape and design (for three, 100mm dia pipes). 941 17.63 Cutting chases in brick masonry walls (clay brick/flyash brick/AAC blocks) for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 sand :6 graded stone aggregate 12.5 mm nominal size) including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 sand) : 17.63.1 100 mm dia 17.63.2 75 mm dia 17.63.3 50 mm dia 942 17.64 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.64.1 Semi rigid pipe 17.64.1.1 32 mm dia 17.64.1.2 40 mm dia 17.64.2 Flexible pipe (only in residential & complaxes) 17.64.2.1 32 mm dia 17.64.2.2 40 mm dia 943 17.65 Providing and fixing 100 mm sand cast Iron grating for gully trap. 944 17.66 Providing and fixing in position 25mm diameter mosquito proof coupling of approved municipal design. 945 17.67 Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 946 17.68 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shape with 6 mm thick hard board backing 17.68.1 Circular shape 450mm dia. 17.68.2 Rectangular shape 453x357mm 17.68.3 Oval shape 450x350mm (outer dimensions) 17.68.4 Rectangular shape 1500x450 mm 947 17.69 Providing and fixing glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 948 17.70 Providing and fixing toilet paper holder: 17.70.1 C.P. brass 17.70.2 Vitreous china 949 17.71 Providing and fixing CP brass waste coupling of approved quality and make for sink and wash basin. 17.71.1 Waste coupling 31mm of 79mm length and 62mm breadth 17.71.2 Waste coupling 38mm of 83mm length and 77mm breadth 950 17.72 Providing and fixing CP brass bottle trap of approved quality and make for sink and wash basin. 951 17.73 Providing and fixing CP brass towel rail of approved quality and make 17.73.1 600x20mm 17.73.2 450x20mm 952 17.74 Providing and fixing CP brass towel ring of approved quality and make 200mm dia ring 953 17.75 Providing and fixing CP brass soap dish of approved quality and make 954 17.76 Providing and fixing CP brass Urinal spreader of approved quality and make 955 17.77 Providing and fixing C.P. brass soap container 109 mm wide, 125 high and 112 mm distance from wall of standard shape with bracket of the same material with all fittings etc. of approved quality and conforming to IS: specification. 956 17.78 Providing and fixing C.P. brass grating of approved quality and make conforming to IS: specification. 17.78.1 100 mm dia. 957 17.79 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 17.79.1 Waste coupling 31mm dia of 79mm length and 62mm breadth weighing not less than 45gms. 17.79.2 Waste coupling 38mm dia of 83mm length and 77mm breadth, weighing not less than 60gms. 958 17.80 Providing and fixing PTMT Bottle Trap for Wash basin and sink. 17.80.1 Bottle trap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 260gms. 17.80.2 Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighting not less than 263gms. 959 17.81 Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. Weighing not less than 105 gms. 960 17.82 Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colour. Weighing not less than 88 gms. 961 17.83 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 17.83.1 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms. 17.83.2 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. 962 17.84 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour. Weighing not less than 300 gms. 963 17.85 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes. Weighing not less than 60 gms. 964 17.86 Providing and fixing PTMT urinal cock of approved quality and colour. 15 mm nominal bore, 80mm long. 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms. 965 17.87 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. 966 17.88 Painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint over a coat of zinc chromate yellow primer (of approved quality) on the outside surface of the cistern, flush pipe, other fittings, etc. complete for new work. 967 17.89 Re-painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint on the outside surface of the cistern, flush pipe, other fittings, etc. complete including polishing of wooden seat and lid and cleaning of W.C. pan with acid wherever necessary. 968 17.90 Repainting C.I. cistern with synthetic enamel paint of approved colour brand and manufacture on the outside surface of cistern flush pipe, other fittings etc. complete. 969 17.91 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 17.91.1 75 mm diameter pipe 17.91.2 100 mm diameter pipe 17.91.3 150 mm diameter pipe 970 17.92 Repainting sand cast iron/ centrifugally cast iron (spun) iron, soil, waste, vent pipes and fittings with one coat of synthetic enamel paint of any colour such as chocolate, grey or buff etc : 17.92.1 75 mm diameter pipe 17.92.2 100 mm diameter pipe 17.92.3 150 mm diameter pipe 971 17.93 Repainting bath tub of size 1700x730x430mm with enamel paint. 972 17.94 Providing and laying Ceramic glazed half round pipe drain (having thickness 9 to 10mm) of approved make in colours such as White, Ivory, Grey, or any other colour, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. 17.94.1 100 mm dia half round pipe 17.94.2 150 mm dia half round pipe 17.94.3 200mm dia half round pipe 973 17.99 Construction of manually operated fire based incinerator for girls-toilet i/c (i)   Fire and ash collection chamber 0.60x0.60 m, made of calcium silicate bricks, having 12mm dia steel bars grating @10 cm c/c, i/c MS mesh weldedon top including 300 mm x 450 mm MS openable door of half grill and half MS plate (3mm thick ).(ii)     0.40 m X 0.40 m duct made of 1.6 mm thick MS sheet for dropping napkins from the toilet opening.(iv) 150mm dia Class C heavy duty MS pipe conforming to IS 3589/1239 for gas emission with cowel, up to 2.10 meter height above terrace level.(v) Opening in wall having MS flap (1.6mm thick) of size 0.25X 0.25 m, finished with granite.etc complete as per standard drawing no. 5313-B-NB4-9919- R1 dated 21.02.2017 17.99.1 For ground floor buildings. 17.99.2 For Ground floor & Ist floor buildings. 17.99.3 Add extra for every additional floor above Ist floor. 974 17.95 Providing and fixing coupler for PVC pipes & fittings waste/rain water/drainage disposal of superior Indian make (as approved by Engineer incharge) i/c jointing with rubber rings, adhesive, lubricant,solvent cement PVC clips or burried underground i/c making necessary chases and holes in walls, floors or trenching complete with making good or i/c excavation and refilling as per site requirement with testing etc.complete. FOR WASH BASIN CONNECTION (40mm diameter) 975 18.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. 18.6.1 Internal work - Exposed on wall 18.6.1.1 15 mm nominal outer dia Pipes. 18.6.1.2 20 mm nominal outer dia .Pipes. 18.6.1.3 25 mm nominal outer dia .Pipes. 18.6.1.4 32 mm nominal outer dia Pipes. 18.6.1.5 40 mm nominal outer dia Pipes. 18.6.1.6 50 mm nominal outer dia .Pipes. 18.6.2 Concealed work including cutting chases and making good the walls etc. 18.6.2.1 15 mm nominal outer dia .Pipes. 18.6.2.2 20 mm nominal outer dia .Pipes. 18.6.2.3 25 mm nominal outer dia Pipes. 18.6.2.4 32 mm nominal outer dia Pipes. 976 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work 18.7.1 15 mm nominal outer dia Pipes. 18.7.2 20 mm nominal outer dia .Pipes. 18.7.3 25 mm nominal outer dia Pipes. 18.7.4 32 mm nominal outer dia .Pipes. 18.7.5 40 mm nominal outer dia Pipes. 18.7.6 50 mm nominal outer dia .Pipes. 18.7.7 62.50 mm nominal inner dia Pipes. 18.7.8 75 mm nominal inner dia .Pipes. 18.7.9 100mm nominal inner dia .Pipes. 18.7.10 150 mm nominal inner dia Pipes. 977 18.8 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. 18.8.1 Internal work - Exposed on wall 18.8.1.1 15 mm dia. nominal bore 18.8.1.2 20 mm dia. nominal bore 18.8.1.3 25 mm dia. nominal bore 18.8.1.4 32 mm dia. nominal bore 18.8.1.5 40 mm dia. nominal bore 18.8.1.6 50 mm dia. nominal bore 18.8.2 Concealed pipe including painting with anti corrosivebitumastic paint, cutting chases and making good the wall. 18.8.2.1 15 mm dia nominal bore 18.8.2.2 20 mm dia nominal bore 18.8.3 External work : including trenching and refilling etc. 18.8.3.1 15 mm dia. nominal bore 18.8.3.2 20 mm dia. nominal bore 18.8.3.3 25 mm dia. nominal bore 18.8.3.4 32 mm dia. nominal bore 18.8.3.5 40 mm dia. nominal bore 18.8.3.6 50 mm dia. nominal bore 18.8.3.7 65 mm dia. nominal bore 18.8.3.8 80 mm dia. nominal bore 978 18.9 Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer -in-charge. (The pipe length inserted in the fitting shall not be measured for payment) 18.9.1 Internal work - Exposed on wall 18.9.1.1 15.88 mm outer diapipe 18.9. 1.2 22.22 mm outer diapipe 18.9.1.3 28.58 mm outer diapipe 18.9.1.4 34.00 mm outer dia Pipe 18.9.1.5 42.70 mm outer dia Pipe 18.9.1.6 48.60 mm outer dia Pipe 18.9.2 Internal work - Concealed Pipe 18.9.2.1 15.88 mm outer dia .Pipes. 18.9.2.2 22.22 mm Outer diaPipes 979 18.12 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.12.1 With C.I. wheel of approved quality (screwed end) 18.12.1.1 25 mm nominal bore 18.12.1.2 32 mm nominal bore. 18.12.1.3 40 mm nominal bore 18.12.1.4 50 mm nominal bore 18.12.1.5 65 mm nominal bore 18.12.1.6 80 mm nominal bore 18.12.2 With brass lever handle of approved quality. 18.12.2.1 25 mm nominal bore 18.12.2.2 32 mm nominal bore. 18.12.2.3 40 mm nominal bore 18.12.2.4 50 mm nominal bore 980 18.13 Providing and fixing CPVC gate valve with knob of approved quality. 18.13.1 25 mm nominal bore 18.13.2 32 mm nominal bore. 18.13.3 40 mm nominal bore 18.13.4 50 mm nominal bore 981 18.14 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.14.1 15 mm nominal bore 18.14.2 20 mm nominal bore 18.14 3 25 mm nominal bore 982 18.15 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.15.1 25 mm nominal bore 18.15.1.1 Horizontal 18.15.1.2 Vertical 18.15.2 32 mm nominal bore 18.15.2.1 Horizontal 18.15.2.2 Vertical 18.15.3 40 mm nominal bore 18.15.3.1 Horizontal 18.15.3.2 Vertical 18.15.4 50 mm nominal bore 18.15.4.1 Horizontal 18.15.4.2 Vertical 18.15.5 65 mm nominal bore 18.15.5.1 Horizontal 18.15.5.2 Vertical 18.15.6 80 mm nominal bore 18.15.6.1 Horizontal 18.15.6.2 Vertical 983 18.16 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 18.16.1 15 mm nominal bore 18.16.2 20 mm nominal bore 18.16.3 25 mm nominal bore 984 18.17 Providing and fixing uplasticised PVC connection pipe with brass unions : 18.17.1 30 cm length 18.17.1.1 15 mm nominal bore 18.17.1.2 20 mm nominal bore 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore 18.17.2.2 20 mm nominal bore 985 18.18 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :- 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.18.2 With well burnt flyash bricks of 50 kg/sqm compressive strength. 986 18.19 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design 18.19.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.19.2 With flyash bricks of 50 kg/cm2 strength 987 18.20 Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 sand) for fire hydrants, with C.I. surface box 350x350 mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 18.20.1 With common burnt clay bricks of 25 kg/cm2 compressive strength. 18.20.2 With flyash bricks of 50kg/cm2 strength. 988 18.21 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 18.21.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.21.2 With flyash bricks of 50kg/sqm compressive strength. 989 18.22 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 18.22.1 15 mm diameter pipe. 18.22.2 20 mm diameter pipe. 18.22.3 25 mm diameter pipe. 18.22.4 32 mm diameter pipe. 18.22.5 40 mm diameter pipe. 18.22.6 50 mm diameter pipe. 990 18.23 Repainting G.I. pipes and fittings with synthetic enamel white paint of approved quality : 18.23.1 15 mm diameter pipe. 18.23.2 20 mm diameter pipe. 18.23.3 25 mm diameter pipe 18.23.4 32 mm diameter pipe 18.23.5 40 mm diameter pipe 18.23.6 50 mm diameter pipe 991 18.24 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 18.24.1 15 mm diameter pipe 18.24.2 20 mm diameter pipe 18.24.3 25 mm diameter pipe 18.24.4 32 mm diameter pipe 18.24.5 40 mm diameter pipe 18.24.6 50 mm diameter pipe 18.24.7 65 mm diameter pipe 18.24.8 80 mm diameter pipe 992 18.25 Providing and filling sand all-round the G.I. pipes in external work. 18.25.1 15 mm diameter pipe 18.25.2 20 mm diameter pipe 18.25.3 25 mm diameter pipe 18.25.4 32 mm diameter pipe 18.25.5 40 mm diameter pipe 18.25.6 50 mm diameter pipe 18.25.7 65 mm diameter pipe 18.25.8 80 mm diameter pipe 993 18.26 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 18.26.1 15 mm nominal bore 18.26.2 20 mm nominal bore 18.26.3 25 mm nominal bore 18.26.4 32 mm nominal bore 18.26.5 40 mm nominal bore 18.26.6 50mm nominal bore 18.26.7 65mm nominal bore 18.26.8 80 mm nominal bore 994 18.27 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.27.1 15 mm nominal bore. 18.27.2 20 mm nominal bore. 18.27.3 25 mm nominal bore. 18.27.4 32 mm nominal bore. 18.27.5 40 mm nominal bore. 18.27.6 50 mm nominal bore. 18.27.7 65 mm nominal bore. 18.27.8 80 mm nominal bore. 995 18.28 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 996 18.29 Providing and fixing brass bib cock of approved quality 18.29.1 15 mm nominal bore 18.29.2 20 mm nominal bore 997 18.30 Providing and fixing brass stop cock of approved quality : 18.30.1 15 mm nominal bore 18.30.2 20 mm nominal bore 998 18.31 Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, and weighing not less then 400 kg, 15 mm nominal bore. 999 18.32 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. 1000 18.33 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gm, 15 mm nominal bore 1001 18.34 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. 1002 18.35 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore 1003 18.36 Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 15 mm nominal bore. 1004 18.37 Providing and fixing C.P. brass pillar cock approved quality and make conforming to IS: specification. nd weighing not less than 650 gm,a15 mm nominal bore 125 mm long foam flow. 1005 18.38 Providing and fixing C.P. brass basin mixer of approved quality and make conforming to IS: specification.15 mm nominal bore. 1006 18.39 Providing and fixing C.P. brass wall mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1007 18.40 Providing and fixing C.P. brass sink mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1008 18.41 Providing and fixing C.P. brass elbow operated bibcock of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1009 18.42 Providing and fixing C.P. brass elbow operated pillar cock of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1010 18.43 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 18.43.1 100 mm diameter 18.43.2 150 mm diameter 18.43.3 200 mm diameter 1011 18.44 Providing and fixing PTMT bib cock of approved quality and colour 15mm nominal bore. 18.44.1 86 mm long weighing not less than 88 gm 18.44.2 122 mm long weighing not less than 99 gm 18.44.3 165mm long weighing not less than 110 gm 18.44.4 90mm long weighing not less than 93 gm 1012 18.45 Providing and fixing PTMT stop cock of approved quality and colour. 18.45.1 15 mm nominal bore, 86mm long. Weighing not less than 88 gms. 18.45.2 20mm nominal bore, 89mm long. Weighing not less than 88 gms. 18.45.3 Concealed stop cock, 15mm nominal bore, 108mm long. Weighing not less than 108 gms. 1013 18.46 Providing and fixing PTMT pillar cock of approved quality and colour. 18.46.1 15mm nominal bore, 107mm long. Weighing not less than 110 gms. 18.46.2 15mm nominal bore, 125mm long foam flow weighing not less than 120 gms. 1014 18.47 Providing and fixing PTMT, push cock of approved quality and colour. 18.47.1 15 mm nominal bore, 98mm long. Weighing not less than 75 gms. 18.47.2 15 mm nominal bore, 80mm long weighing not less than 46 gms. 1015 18.48 Providing and fixing PTMT grating of approved quality and colour. 18.48.1 Circular type. 18.48.1.1 100 mm nominal dia. 18.48.1.2 125 mm nominal dia with 25 mm waste hole. 18.48.2 Rectangular type with openable circular lid. 18.48.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating. 1016 18.49 Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. 1017 18.50 Providing and fixing PTMT swivelling shower, 15mm nominal bore. Weighing not less than 40gms. 1018 18.51 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 18.51.1 15 mm nominal bore, 105 mm long. Weighing not less than 138 gms. 18.51.2 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. 18.51.3 25 mm nominal bore, 152mm long. Weighing not less than 440 gms. 18.51.4 40mm nominal bore, 206mm long. Weighing not less than 690 gms. 18.51.5 50mm nominal bore, 242mm long. Weighing not less than 1240 gms. 1019 18.52 Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour 15 mm nominal bore 18.52.1 30cm length. 18.52.2 45 cm length. 1020 18.53 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 18.53.1 15 mm nominal bore.Weighing not less than 32 gms. 18.53.2 20mm nominal bore.Weighing not less than 40gms. 18.53.3 25mm nominal bore.Weighing not less than 62 gms. 1021 18.54 Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 18.54.1 80 mm nominal bore 18.54.2 100 mm nominal bore 18.54.3 150 mm nominal bore 18.54.4 200 mm nominal bore 1022 18.55 Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : 18.55.1 80 mm nominal bore 18.55.2 100 mm nominal bore 18.55.3 150 mm nominal bore 18.55.4 200 mm nominal bore 1023 18.56 Cutting holes upto 30x30 cm in walls including making good the same : With common burnt clay bricks of 25 kg /sqcmor flyash bricks of 50 kg/cm2compressive strength. 1024 18.57 Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. 1025 18.58 Making chases upto 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1026 18.59 Making hole upto 20x20 cm and embedding pipes upto 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) including disposal of malba. 1027 18.60 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 18.60.1 25 to 40 mm nominal bore 18.60.2 50 to 80 mm nominal bore 1028 18.61 Providing and fixing CP jet assembly to including connection etc complete. 1029 18.62 Providing and fixing ferro- cement water storage tank with cover, having minimum thickness of 10mm. The wall to be reinforced with two layers of double galvanized annealed square wooven wire mesh of 20 gauge wire spaced at 15mm for 300 litre capacity and 12mm for 450 to 2500 litres capacity finish with 3 layers of Cement mortar 1:2 duly modified with polymer based plastizers and hardening chemicals (Burogrout and Buroseal) The tank should conform to the specification prescribed by Structural Engineering Research Centre Roorkee/Gaziabad. The tanks to be painted with drinking water paint inside and aluminimum paint out side with provision of outlet, inlet, overflow and cleaning including hoisting and placing in position upto floor two level or 5 M. height. 1030 18.63 Add extra for additional floor lift beyond 5.0M.height. 1031 19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.1.1 100 mm diameter 19.1.2 150 mm diameter 19.1.3 200 mm diameter 19.1.4 230 mm diameter 19.1.5 250 mm diameter 19.1.6 300 mm diameter 1032 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 19.2.1 100 mm diameter S.W. pipe 19.2.2 150 mm diameter S.W. pipe 19.2.3 200 mm diameter S.W. pipe 19.2.4 230 mm diameter S.W. pipe 19.2.5 250 mm diameter S.W. pipe 19.2.6 300 mm diameter S.W. pipe 1033 19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design : 19.3.1 100 mm diameter S.W. pipe 19.3.2 150 mm diameter S.W. pipe 19.3.3 200 mm diameter S.W. pipe 19.3.4 230 mm diameter S.W. pipe 19.3.5 250 mm diameter S.W. pipe 19.3.6 300 mm diameter S.W. pipe 1034 19.4 Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly. 19.4.1 110 mm diameter OD (min. wall thickness 3.2mm) 19.4.2 160 mm diameter OD (min. wall thickness 4.0mm) 19.4.3 200 mm diameter OD (min. wall thickness 4.9mm) 19.4.4 250 mm diameter OD (min. wall thickness 6.2mm) 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) 1035 19.5 Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20 mm nominal size) all-round PVC. pipes including bed concrete as per standard design: 19.5.1 110 mm diameter PVC. pipe 19.5.2 160 mm diameter PVC. pipe 19.5.3 200 mm diameter PVC. pipe 19.5.4 250 mm diameter PVC. pipe 19.5.5 300 mm diameter PVC pipe 1036 19.6 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) up to haunches of PVC. pipes including bed concrete as per standard design : 19.6.1 110 mm diameter PVC. pipe 19.6.2 160 mm diameter PVC. pipe 19.6.3 200 mm diameter PVC. pipe 19.6.4 250 mm diameter PVC. Pipe 19.6.5 300 mm diameter PVC pipe 1037 19.7 Providing and fixing square- mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 19.7.1 100x100 mm size P type 19.7.1.1 With well burnt bricks 19.7.1.2 With Sewer bricks conforming to IS : 4885 19.7.2 150 x 100 mm size P type. 19.7.2.1 With well burnt bricks 19.7.2.2 With sewer bricks conforming to IS : 4885 19.7.3 180x150 mm size P type 19.7.3.1 With well burnt bricks 19.7.3.2 With Sewer bricks conforming to IS : 4885 1038 19.8 Providing and laying non- pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : 19.8.1 100 mm dia. R.C.C. pipe 19.8.2 150 mm dia. R.C.C. pipe 19.8.3 250 mm dia. R.C.C. pipe 19.8.4 300 mm dia. R.C.C. pipe 19.8.5 450 mm dia. R.C.C. pipe 19.8.6 500 mm dia. R.C.C. pipe 19.8.7 600 mm dia. R.C.C. pipe 1039 19.9 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks 19.9.1.2 With Sewer bricks conforming to IS : 4885 19.9.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 19.9.2.1 With well burnt bricks 19.9.2.2 With Sewer bricks conforming to IS : 4885 19.9.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : 19.9.3.1 With well burnt bricks 19.9.3.2 With Sewer bricks conforming to IS : 4885 1040 19.10 Extra for depth for manholes 19.10.1 Size 90x80 cm 19.10.1.1 With well burnt bricks 19.10.1.2 With Sewer bricks conforming to IS : 4885 19.10.2 Size 120x90 cm 19.10.2.1 With well burnt bricks 19.10.2.2 With Sewer bricks conforming to IS : 4885 1041 19.11 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete. (Foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : 19.11.1 With well burnt bricks 19.11.2 With Sewer bricks conforming to IS : 4885 1042 19.12 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91m to 1.67m 19.12.1 With well burnt bricks 19.12.2 With Sewer bricks conforming IS : 4885 1043 19.13 Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 including centering shuttering all complete. (Foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) 19.13.1 With well burnt bricks 19.13.2 With Sewer bricks conforming IS : 4885 1044 19.14 Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29 m : 19.14.1 With well burnt bricks 19.14.2 With Sewer bricks conforming IS : 4885 1045 19.15 Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design : 19.15.1 2.30m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) including centering shuttering all complete. (Foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 19.15.1.1 With well burnt bricks 19.15.1.2 With Sewer bricks conforming IS : 4885 1046 19.16 Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : 19.16.1 With well burnt bricks 19.16.2 With Sewer bricks conforming IS : 4885 1047 19.17 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 19.17.1 With 20x20 mm square bar 19.17.2 With 20 mm diameter round bar 1048 19.18 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1049 19.19 Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size): 19.19.1 With 20x20 mm square bar 19.19.2 With 20 mm diameter round bar 1050 19.20 Supplying and fixing C.I. cover without frame for manholes : 19.20.1 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. 19.20.2 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg. 19.20.3 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg. 1051 19.21 Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality 19.21.1 Light duty D- 2.5 19.21.1.1 Rectangular shape 600x450mm internal dimensions 19.21.1.2 Square shape 450mm internal dimensions 19.21.1.3 Circular shape 450mm internal diameter 19.21.2 Medium duty - 10 19.21.2.1 Square shape 450mm internal dimension 19.21.2.2 Circular shape 500mm internal diameter 19.21.3 Heavy duty D - 20 19.21.3.1 Circular shape 560 mm internal diameter 19.21.4 Extra Heavy Duty - 35 19.21.4.1 Circular shape 560 mm internal dia. 1052 19.22 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg. 1053 19.23 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 19.23.1 For pipes 100 to 230 mm diameter 19.23.2 For pipes 250 to 300 mm diameter 19.23.3 For pipes 350 to 450 mm diameter 1054 19.24 Providing sand cast iron drop connection externally for 60 cm drop from branch sewer line to main sewer manhole including inspection and cleaning eye with chain and lid, sand cast iron drop pipe and bend encased all-round with cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) with cement mortar 1:1 (1 cement : 1 sand) joints between sand cast iron tee and S.W. pipe, making required channels complete as per standard design and specifications : 19.24.1 100 mm dia. sand cast iron drop connection 19.24.2 150 mm dia. sand cast iron drop connection 1055 19.25 Extra for depths beyond 60 cm of sand cast iron drop connection complete : 19.25.1 For 100 mm dia. sand cast iron drop connection 19.25.2 For 150 mm dia. sand cast iron drop connection 1056 19.26 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Brick work for Raising depth of manhole to be paid separately) : 19.26.1 Rectangular manhole 90x80 cm with rectangular cover 600x450 mm of grade LD - 2.5 19.26.2 Rectangular manhole 120x90 cm with circular cover 500 mm dia of grade MD - 10 19.26.3 Rectangular manhole 120x90 cm with circular cover 560 mm dia of grade HD - 20 19.26.4 Circular manhole 140 cm dia with circular cover 600 mm dia of grade Extra heavy duty HD -35 1057 19.27 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design : 19.27.1 With well burnt bricks 19.27.2 With fly ash bricks 100 key/cm2 strangth 1058 19.28 Constructing brick masonry road gully chamber 45x45x77.5cm with bricks in cement mortar 1:4 (1 cement : 4 sand) with precast R.C.C. vertical grating complete as per standard design : 19.28.1 With well burnt bricks 19.28.2 With fly ash bricks 100 kg/cm2 strength 1059 19.29 Constructing brick masonry road gully chamber 110x50x77.5cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : 19.29.1 With well burnt bricks 19.29.2 With fly ash bricks 100 kg/cm2 strength 1060 19.30 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.30.1 With well burnt bricks 1061 19.31 Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design. 1062 19.32 Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 sand) including testing of joints etc. complete : 19.32.1 100 mm dia 19.32.2 150 mm dia 1063 19.33 Providing, laying and jointing half round glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.33.1 100 mm dia 19.33.2 150 mm dia 19.33.3 200 mm dia 19.33.4 230 mm dia 19.33.5 250 mm dia 19.33.6 300 mm dia 1064 19.34 Providing and laying half round RCC pipes class (light duty) with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.34.1 100 mm dia. Half round R.C.C. pipe 19.34.2 150 mm dia. Half round R.C.C. pipe 19.34.3 250 mm dia. Half round R.C.C. pipe 19.34.4 300 mm dia. Half round R.C.C. pipe 1065 19.35.1 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.1.1 & 19.9.1.2 19.35.2 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.2.1 & 19.9.2.2 19.35.3 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.3.1 & 19.9.3.2 1066 19.36 Providing & Fixing of Precast RCC drain cover of size 600x 450 x70mm (thickness) with 4 holes, manufactured by using M-30 grade of concrete reinforced with 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1067 19.37 Providing & Fixing of Precast RCC drain cover of size 750x600 x70mm (thickness) with 6 holes, manufactured by using M-30 grade of concrete reinforced with 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1068 19.38 Providing & Fixing of Precast RCC drain cover of size 900x450 x90mm (thickness) with 8 holes, manufactured by using M-30 grade of concrete reinforced with two layers of 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @ top face will have broom finish etc complete. 1069 19.39 Providing & Fixing of Precast RCC drain cover of size 1150x400 x100mm (thickness) with 10 holes, manufactured by using M-30 grade of concrete reinforced with two layers of 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1070 19.40 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 900X450mm rectangular having weight of (complete unit) (weight of frame 11.7 kg + weight of cover 43.76kg ± 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. Having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1071 19.41 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 450X600mm rectangular having weight of (complete unit) (weight of frame 1.84kg + weight of cover 14.2kg ± 10%) (LD/2.5MT) having load bearing capacity (Point load 2.5MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1072 19.42 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 300X300mm (square) having weight of (complete unit) (weight of frame 1.12kg + weight of cover 4.1kg ± 10%) (LD/2.5MT) having load bearing capacity (Point load 2.5MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1073 19.43 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 600mm (round) having weight of (complete unit) (weight of frame 13.6kg + weight of cover 43.1kg + - 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5 mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement 1074 19.44 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 500mm (round) having weight of (complete unit) (weight of frame 11.2kg + weight of cover 41.78kg ± 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. Having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement 1075 19.45 Deduct for not providing and installing FRP/GRP manhole cover size 19.45.1 900mmx450mm (weight of cover 43.76kg ± 10%) 19.45.2 450mmx600mm (weight of cover 14.2kg ± 10%) 19.45.3 300mmx300mm (weight of cover 4.1kg ± 10%) 19.45.4 600mm (weight of cover 41.78kg ± 10%) 19.45.5 500mm (weight of cover 43.1kg ± 10%) 1076 19.46 Providind, laying and jointing HDPE Double Wall corrugated (DWC) pipes (excavation to be paid seperately) 19.46.1 100 mm dia to 110 mm dia 19.46.2 150 mm dia to 160 mm dia 19.46.3 200 mm dia 19.46.4 250 mm dia 19.46.5 300 mm dia 1077 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) 21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) 21.1.2 For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) 21.1.3 Deduct for not providing EDPM rubber/neoprene gasket all around. 1078 21.2 Providing and fixing 12mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. 21.2.2 Pre-laminated particle board with decorative lamination on both sides. 1079 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). 1080 21.4 Add extra for providing and fixing froasted glass instead of float glass 21.4.1 With glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) 21.4.2 With glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) 21.4.3 With glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). 1081 21.5 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body /plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge : 21.5.1 With stainless steel cover plate - minimum 1.25 mm thickness 21.5.2 With brass cover plate - minimum 1.25 mm thickness. 1082 21.6 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). 1083 21.7 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-charge. 1084 21.8 Providing and fixing machine moulded aluminium covering of approved pattern and design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick and 15 mm dia, at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-Charge : 21.8.1 Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 21.8.2 Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) 1085 21.9 Filling the gap in between aluminium frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width 1086 21.10 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. For fixed portion & for shutters of doors, windows and ventilators 1087 21.11 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete. 1088 21.12 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick and length as required with SS screws etc complete as per direction of Engineer-in-Charge. 21.12.1 Anodized (AC 15 ) aluminium tubular handle bar 21.12.2 Powder coated minimum thickness 50 micron aluminium tubular handle bar. 21.12.3 Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar. 1089 21.13 Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 1090 21.14 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). 1091 21.15 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. 21.15.1 Anodized (AC15) aluminium 21.15.2 Powder coated minimum thickness 50 micron aluminium. 21.15.3 Polyester powder coated minimum thickness 50 micron aluminium. 1092 21.16 Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-Charge 21.16.1 Anodized (AC15 ) aluminium 21.16.2 Powder coated minimum thickness 50 micron aluminium 21.16.3 Polyester powder coated minimum thickness 50 micron aluminium. 1093 21.17 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge. (Only weight of grill to be measured for payment). 1094 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-Charge (Door handle, lock and stopper etc.to be paid separately). 1095 21.19 Providing and fixing 50 micron thick reflective one way type heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in-charge of approved brand and make. 1096 21.20 Providing and fixing 50 micron thick Frosted heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in-charge of approved brand and make. 1097 21.21 Providing and fixing 25 micron thick Non reflective heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in- charge of approved brand and make. 1098 21.22 Providing and fixing 12 mm thick toughened glass including all connectors and fixing accessories all complete for partitions, cubicals etc. As per direction of Engineer-in-Charge. 1099 21.24 Extra for froasted glass (with eching film) in item No. 21.22 1100 22.1 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge consisting of: (i)     Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement: 3 sand) mixed with water proofing compound conforming to IS: 2645 in the recommended proportion over the levelling course ( levelling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii)         2nd layer of 25mm thick cement mortar 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportions. (iii)        Finishing top with stone aggregate of 10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (with 5 years service guarantee) Using rough Kota stone. 1101 22.2 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge (with 5 years service guarantee) Using rough Kota stone. 1102 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : a)   Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. b)   IInd course of 20mm cement plaster 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. c)    IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. d)      IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) (with 5 years service guarantee) 1103 22.4 Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete (with 5 years service guarantee) 22.4.1 Serrated with central bulb (225mm wide, 8- 11mm thick). 22.4.2 Dumb bell with central bulb (180mm wide, 8mm thick). 22.4.3 Kickers (320mm wide, 5mm thick). 1104 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a)  First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b)  Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1105 22.6 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a)     After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b)    Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c)   Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. 1106 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a)  Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b)  Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in- Charge: (with 5 years service guarantee) With average thickness of 120mm and minimum thickness at khurra as 65 mm. 1107 22.8 Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea-sized gravel spread at 6 cubic decimeter per square metre including preparation of surface but excluding grading complete with : (with five years service gurantee). Bitumen felt (hessian base) type 3 grade I conforming to IS: 1322. 1108 22.9 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45, 1.20 and 1.45 Kg per square metre of area respectively, second and fourth courses of roofing felt type 3 grade I conforming to IS : 1322 (Hessian based self finished bitumen felt) conforming to IS : 1322 and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee). 1109 22.10 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6cu.dm per sqm including preparation of surface, excluding grading, complete. (With five years service gurantee). 1110 22.11 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blow or/ and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade II (glass fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee) 1111 22.12 Deduct for omitting in water proofing treatment final course of spreading stone grit 6mm down size or pea sized gravel at 6 cudm per sqm. 1112 22.13 Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm. 1113 22.14 Grading roof for receiving water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) 22.14.2 Cement mortar 1:3 (1 cement : 3 sand) 22.14.3 Cement mortar 1:4 (1cement : 4 sand) 1114 22.15 Providing and laying insitu six course water proofing treatment with APP (Atactic poly- propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm,conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. (with 5 years service guarantee) 1115 22.16 Providing and laying in situ four course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. (with 5 years service guarantee). 1116 22.17 Providing and laying in situ six course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. (with five years service gurantee). 1117 22.18 Providing and fixing APP (Atactic Polypropylene Polymer) modified prefabricated five layer 2mm thick water proofing membrane for corrugated roof sheets, black finished reinforced with glass fibre matt consisting in longitudinal and transverse direction at 23°C as 350/300 N/ 5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. (With five years service gurantee). 1118 22.19 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer of the membrane shall be as under:Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : (with 5 years service guarantee) 1119 22.20 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacture of density at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane: (with 5 years service guarantee). 1120 22.21 Extra for covering top of membrane with Geotextile, 120gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. [for item No. 22.18 to 22.20] 1121 22.22 Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of (i)   Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely. (ii)     Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80% chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2nd coat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow the coating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per manufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area. (iv) The treated area should be cure with water for 48 hrs. by flooding the surface. (v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) 1122 22.23 Providing water proofing treatment over Roof, Wall, Chhajjas, Balcony with Rubberized elastomeric cold applied liquid waterproofing membrane blend of special resin and rubber with more than 1300% elongation (confirming ASTM-D2370-98), at leakage/seepage area consisting of the following operation. (i)Removal of damaged waterproofing treatment if any like bituminous membrane / plaster/ brick bat koba/screeding etc. (ii) Surface preparation: Roughening of surface by scrubbing with steel wire/ Nylon brush/ Removing all dust particles and washing with adequate water to clean completely, opening of cracks in V groove in size of 5mm x 10m (WxD), filling of cracks with elastomeric creak filler/PU sealent repair of potholes and holor making on roof surface by polymer mortar with adding SBR bonding agent. (iii) Providing and applying 1st coating of rubberized elastomeric liquid membrane as primer (ratio 1:2 1 part liquid membrane and 2 part water) by brush/ Roller/ Spray having minimum thickness of 70-80 micron. Allow the coating to set in natural air for minimum 2 hrs, then put reinforcement by laying 45gsm fibre glass mesh and applying 2nd coat of rubberized elastomeric liquid membrane (Ratio: 1 part membrane and 20% water) with minimum thickness 100-120 micron. Allow the coating to set in natural air for minimum 12 hrs. (iv) Providing and applying 3rd coat of rubberized elastomeric liquid membrane (Ratio: 1 part membrane and 10% water). Total DFT (Dry film thickness) thickness after 3rd coat must be 280-300 micron and consumption in three coats @ 6.5kg for 10sqm. (v) Providing and applying 4th and 5th coat of High quality waterproof membrane in white colour, single component special synthetic resin based flexible thixotropic white color coating with excellent UV resistance (SRI - 144) with more than 300% elongation (confirming ASTM D 412-98) in ratio: 1 part membrane and 10% water thickness of 200 micron DFT in two coats, with average consumption @ 5kg per 10 sqm. After application of fourth coat let it air dry for minimum 3 hrs before application of fifth coat. (vi) The treated area must be tested for water leakage/seepage by flooding with water for 48 hrs (vii) Application of membrane coating shall be got done by authorized applicator of manufacturer. (viii) 5 years of service guarantee to be provided.All above operations to be done in order as per direction on Engineer-in-Charge. 1123 22.24 Supplying and applying fibre reinforced, UV resistant elastomeric liquid applied waterproofing & Heat reflective coating coating with PU Hybrid polymers & acrylic fibers. The coating shall resist 10 bars of water pressure as per DIN 1048 standards, with elongation of 350% as per ASTM D412 & crack bridging of upto 2.5mm conforming to ASNZ standard. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and as per the direction of Engineer-in-Charge. 1124 22.25 Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, having 80% elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturers specifications and as per direction of Engineer-in-Charge. 1125 22.26 Providing and applying UV Stable polyurethane liquid water proofing membrane having Sun Reflectivity Index (SRI) of 106 on top of concrete roof / Retainning wall / Old layer of bituminous surfaces / Polyurethane foam and metal surfaces in three or more coats @20kg/ 10 sqm consisting of a coat of two component epoxy primer in ratio of 1:3(one part of resin and 3 parts of hardner) at a consumption of 2kg/10sqm. the vital physical and chemical parameters shall be as under : Min Elongation at break of 600% as per ASTM D412 and tensile strength of 3.0 N/mm2 as per ASTM D412. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and direction of Engineer-in-Charge. 1126 22.27 Supplying & installing waterproofing treatment by using 1.2 mm thick HDPE membrane before casting of the base RCC slab. The pre-applied membrane gets bonded to the underneath of the poured concrete used as base slab. The membrane shall consist of a thick HDPE film, a highly aggressive pressure sensitive adhesive and weather resisting coating which bonds integrally to poured concrete of base slab. The membrane shall conforms to basement waterproofing protection to grades 2, 3 & 4 as defined in BS 8102:2009. The waterproofing membrane shall have following minimum properties: a)    Resist hydrostatic pressure of up to 70 m head of water as per ASTM D5385; b)      Puncture Resistance of 950 N (as per ASTM E154) c)      Elongation of >400 % (as per ASTM D412) d)    Peel Strength of concrete: >1500 N/m (as per ASTM D903) e)      Tensile strength of 28.2 MPA (as per ASTM D412). 1127 22.28 Providing and applying 2.0 mm thick twin colour flexible PVC waterproofing membrane. Flexibility under low temperatures as per EN 495-5 should be < - 20degC. On all horizontal surfaces Geotextile 300 Gsm to be laid over PCC, than laying PVC membrane over Geotextile and to be sealed with hot air welding method at all joints and over PVC membrane provide 300 Gsm Geotextile Then protection screed of suitable thickness. On all vertical surfaces Geotextile 300 Gsm to be laid along with Vertical wall, than laying PVC membrane over Geotextile and to be sealed with hot air welding method at all joints and over PVC membrane providing protection layer of Drain Board HDPE Dimple sheet before back filling of soil. 1128 22.29 Providing and applying waterproofing & Heat reflecting roof coating with 100% acrylic elastomeric polymers. Contains 30% Volume solid, tensile strength 8 kg/cm², crack bridging, VOC 30 ± 5 gm/ltr upto 2 mm. then applying two coats with forced coverage of 20 sqft/ltr/two coats. The operation shall be carried out after scrapping & propely clening the surface to remove loose particles with wire brush/Jet washer. Apply 1 coat @1 ltr/10 sqm & 3 undiluted coats @ 8 ltr/10 sqm with 4 hrs interval of each coat.The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer- in-Charge. 1129 22.30 Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. Apply 2nd coat with filling of crack fill paste when the surface is tacky but not dried completely with putty knife & spatula.After 4 hours of application 2nd coat apply 3rd coat of Crack fill paste. The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer-in-Charge 1130 22.31 Providing & applying single pack component, solvent-free, cold applied, Polyurethane modified, elastomeric liquid applied waterproofing membrane- PU coat with excellent UV resistant capacity, The material shall meet the requirement as specified in ASTM D2370-98 of elongation at break of film>350% with geotextile fleece =50% approx.The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer- in-Charge. The product performance shall carry guaranteed for 5 year against any leakage. 22.31.1 For Horizontal surface (with Geotextile fleece) two coats without dilution & 1 Self priming coat- 50% dilution with water @ 10 kg/m2 22.31.2 For Horizontal surface (without Geotextile fleece) two coats without dilution & 1 Self priming coat- 50% dilution with water @ 10 kg/m2 1131 22.32 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and Compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-Charge. The product performance shall carry guarantee for 10 years against any leakage. 1132 22.33 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on positive side. The crystalline slurry shall be capable of self- healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 22.33.1 For vertical surface two coats @ 0.70 kg per sqm 22.33.2 For horizontal surface one coat @1.10 kg per sqm. 1133 22.34 Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. crystalline dryshake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product Performance shall carry guarantee for 10 years against any leakage. 1134 22.35 Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 > 45 MPa and adhesive bond strength Class R3 > 1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge.The product performance shall carry guarantee for 10 years against any leakage. 22.35.1 For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. 22.35.2 For patching of tie rod holes, prepared tie rod hole surface and then primed the area with integral crystalline slurry @ 0.070 kg/sqm and while the surface is tacky repair and then filled the tie rod holes with crystalline mortar @ 0.040 kg per hole. The crystalline mortar should be tightly rodded into tie rod holes or packed tightly (For 25x25x25 mm tie rod hole, use 0.040 kg to fill the hole) 1135 22.36 Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 1136 22.37 Providing and applying waterproofing treatment in bathroom or tiled balcony area without breaking or removing tiles, by using waterproofing sheets as per manufacturers data sheet instructions. Permitting use of bathroom/balcony after 24 hours of application of treatement, Complete with materials and labour and gurantee of leakage for a period of 5 year. 1137 23.11 Providing and fixing 2 mm thick homogeneous conductive PVC (Poly Vinyl Flooring) EN (European Standard), total weight is 3250 g/m2, approx. PUR (Polyurethane Reinforced ), abrasion group P: ≤2.00 mm, residual indentation approx. 0.03 mm, anti-bacterial and fungal resistance, castor wheel test qualified, dimensional Phthalate free, directional in design.The floor finish should be termite free at the room perimeter passing over a concealed cove forming and continuing up on the wall upto 100mm.Recommended to use in area like ICU , Post operative, Recovery rooms, OPD, Patient rooms, Corridors ,passages etc. 1138 23.12 Providing and fixing permanently static dissipative pressed homogeneous conductive PVC ( Poly Vinyl Flooring) EN (European Standard), anti static, wear layer thickness is 2mm (EN429), vinyl flooring having carbon backing with total weight 3000 g/m2 ESD approved, restorable properties, available in rolls. 100% recyclable (eco - freindly). Low VOC emission after 28days of installation (lower than ≤100μg/m3), Phthalate free non-directional in Design. Recommended to use in area like Operation theater, ICU, Server room, etc. 1139 23.13 Providing and fixing 0.92mm thick hetrogeneous compact PVC (Poly Vinyl Wall Covering) for Interior wall area, with wear layer thickness 0.12mm of PVC, EN(European Standard) total weight is 1500 g/m2, approx PUR (Polyurethane Reinforced), good resistance to chemical and fire, doesn’t favour in growth of fungi and bacterial, 100% recyclable (eco-freindly), low VOC emissions after 28 days of installation (lower than ≤10μg/m3), phthalate free, directional in design, The wall finish should termite free at the room perimeter. Recommended to use in area like OT,ICU, Corridors, Patient Room etc. 1140 23.14 Providing and fixing 1.3mm thick homogeneous PVC (Poly Vinyl Wall Covering) for interior area with wear layer thickness 1.3 mm of PVC, EN (European Standard) total weight is 2100 g/m2,approx. PUR (Polyurethane Reinforced), good resistant to chemical and fire, doesn’t favour in growth of fungi and bacterial, 100% recyclable (eco-freindly), low VOC emissions after 28days of installation (lower than ≤10μg/m3), phthalate free, directional in design.The wall finish should termite free at the room. Recommended to use in area like OT.ICU,Corridors, Passages , Patient Room Etc 1141 23.15 Supply and installation of 2mm thick homogeneous vinyl flooring, Highest abrasion wear rating Group T (EN660), binder content exceeds 55% of the flooring composition, no waste technology, consisting of PVC resin, plasticizers and stabilizers, type I. flooring ( (EN ISO 23997) max 0.4%, Abrasion group (MSZ EN 660-1) T, Fire resistance EN 13501-1 BF1-s1, Slip resistance DIN 51130 R9, EN 13893 DS, electrical resistance EN 1815 <2 kv, Chemical resistance EN ISO 26987, Castor chair resistance EN ISO 4918, Hygenie Bacterial resistant, Seaming method - hot welding, finishing complete . Recommended to use in area like Operation theater, ICU, Server room, etc. 1142 24.8 Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with self- drilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm. 1143 24.9 Providing and fixing thermal insulation with Resin Bonded glass wool conforming to IS: 8183, having density 48 kg/m3. 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held and in position by crisscrossing GI wire etc. complete as per directions of Engineer-in-Charge. 24.9.1 Providing and fixing insulation with resin bonded Glass wool 24.9.2 Providing and fixing insulation with resin bonded Rock wool 1144 24.11 Providing and fixing precoatedgalvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsmlength upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1145 24.12 Providing and fixing precoatedgalvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5- 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self-tapping screws complete : 24.12.1 Ridges plain (500 - 600mm). 24.12.2 Flashings/ Aprons.( Upto 600 mm) 24.12.3 North light curves. 24.12.4 Barge board (Upto 300 mm). 24.12.5 Crimp curve 24.12.6 Gutter. (600 mm over all girth). 1146 25.1 Providing and fixing white vitreous china Anti germ Fluoro-Polymer Coated Water closet squatting pan with 100 mm sand cast Iron P and S- trap, and 7.2 liter Low level, dual flush, PP (Poly Propylene) made open slim wall hung cistern capacity 3 liter/6 liter flushing, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440x575x250 mm With integral foot rests. (Premium Range) 25.1.2 White Vitreous china Anti germ Fluoro-Polymer coated Orissa pattern W. C. pan of size 410x515x255 mm with integral foot rests. (Premium Range) 1147 25.2 Providing and fixing white vitreous china pedestal type Anti germ Fluoro-Polymer Coated Water Closet with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propeline) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.2.1 Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan size 360x545x395 mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.2.2 Anti-germ Fluoro-Polymer Coated Water Closet European type W. C. pan size 360x545x395 mm with solid poly propelyne made soft closing seat cover (Premium Range) 1148 25.3 Providing and fixing white vitreous china European Wall hung Anti germ Fluoro-Polymer Coated water closet of approved shape with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propylene) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380x520x375 mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.3.2 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 390x570x365 mm with solid poly propelyne made, soft closing seat cover (Premium Range) 25.3.3 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500x360 mm with solid poly propelyne made, soft closing seat cover (Premium Range) 25.3.4 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360x500x330 mm or greater size with solid poly propelyne made, soft closing seat cover (Premium Range) 1149 25.4 Providing and fixing white vitreous china Anti germ fluoro-polymer coated couple water closet flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required with all fittings and fixtures etc. complete . 25.4.1 Anti germ Fluoro-Polymer Coated couple water closet Size 420x710x810 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.2 Anti germ Fluoro-Polymer Coated couple water closet Size 380x610x805 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.3 Anti germ Fluoro-Polymer Coated couple water closet Size 370 x 640 x 760mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.4 Anti germ Fluoro-Polymer Coated couple water closet Size 375 x 650 x 800 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 1150 25.5 Providing and fixing white vitreous china Anti germ fluoro-polymer coated single piece W.C. dual flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.5.1 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370x695x795 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.2 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 395x710x730 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.3 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 385 x 720 x 710mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.4 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 360 x 640 x 685 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 1151 25.6 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet along with dual flushing cistern flushing capacity 3 & 6 litre approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.6.1 Anti germ Fluoro-Polymer Coated extended wall hung type couple closet Size 760X360X635mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.6.2 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet Size 380x650x730 mm along with dual flushing cistern flushing capacity 3 & 6 litre. (Premium Range) 1152 25.7 Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with C.I. Brackets, 15 mm C. P. wall mounted pressmatic pillar cock auto closing system (decol technology), 15mm quarter turn angular stop cock, 32 mm C.P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required. 25.7.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185 mm with basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) 1153 25.8 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system (decol technology), 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.8.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 570x820x195 mm with wall mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) 25.8.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570x820x195 mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system (decol technology). (Premium Range) 1154 25.9 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted single lever concealed basin mixture, (cartridge size 32 mm) 32 mm C. P. brass waste coupling length 130mm and 32 mm C. P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range) 25.9.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range) 25.9.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 600x400x185 mm with 15 mm C. P. wall mounted single lever concealed basin mixture. (Premium Range) 1155 25.10 Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with 15 mm Table mounted single lever Tall boy basin mixture, (cartridge size 32 mm) 15mm quarter turn angular stop cock, 32 mm C. P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required. 25.10.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185 mm with Table mounted single lever Tall boy basin mixture, (cartridge size 32mm.) (Premium Range) 25.10.2 White vitreous china type Anti germ fluoro- polymer coated counter top wash basin Size 530x420x140 mm with tall boy basin mixture, (cartridge size 32 mm). (Premium Range) 1156 25.11 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated urinal (Inbuilt spreaders, bottle trap and ceramic waste coupling) with 15mm brass pressmatic auto closing concealed urinal flush valve with wall flange (decol technology, 400000 operation warranted) i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . 25.11.1 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm. (Premium Range) 25.11.2 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 475x315x715 mm. (Premium Range) 25.11.3 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 385x325x635 mm. (Premium Range) 1157 25.12 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling)with sensotronic concealed type flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required . 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve for urinal complete set with installation box with control cock. (Premium Range) 25.12.2 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385x325x635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range) 1158 25.13 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) with 15mm Brass made pressmatic (Decol technology, 400000 operation warranted) concealed flushing Stop cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required . 25.13.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 480x300x740 mm with 15mm Brass made pressmatic auto closing concealed urinal flush valve with wall flange (Decol technology, 400000 operation warranted). (Premium Range) 1159 25.14 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling)with sensor complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required. 25.14.1 White Vetrious China made Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) Size 340x325x650 mm with sensor (Premium Range) 25.14.2 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated Urinal size 7475x315x715 mm (Inbuilt spreaders, bottle trap and ceramic waste coupling) with inbuilt sensor for flushing. (Premium Range) 1160 25.15 Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with chrome plating. (Premium Range) 1161 25.16 Providing & Fixing 8mm thick froasted Urinal glass partition size height 900 mm top width 450mm and bottom width 300mm brass made bracket with chrome plating. (Premium Range) 1162 25.17 Providing & Fixing plain bath tub of size 180x80x47cm body made of PMMA (Poly Methyl metha acrylate) with 20mm wooden reinforcement. (Premium Range) 1163 25.18 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Pillar cock. (Premium Range) 1164 25.19 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn)Bib cock. (Premium Range) 1165 25.20 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating. 10 micron and chrome plating 0.3 micron, quarter turn) Angular stop cock. (Premium Range) 1166 25.21 Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Concealed stop cock. (Premium Range) 1167 25.22 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Wall Mixer with 115mm bend. (Premium Range) 1168 25.23 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 3-in1 Wall Mixer .(Premium Range Sanitary Ware) 1169 25.24 Providing and fixing in position best Indian C. P. brass made quarter turn (Ceramic disc Size 25mm) Flush Cock for Indian W. C. (Orissa Pan). (Premium Range) 1170 25.25 Providing and fixing in position best Indian single Lever Auto Mixing Wall Mixer (Cartridge Size 40mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range) 1171 25.26 Providing and fixing in position best Indian single Lever Auto mixing Basin Mixer (Cartridge Size 32mm, nickel plating 0.10 micron and chrome plating 0.3 micron) For Wash Basin area use only. (Premium Range) 1172 25.27 Providing and fixing in position best Indian single Lever Auto Mixing Diverter (Cartridge Size 47mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range) 1173 25.28 Providing and fixing in position best Indian C. P. brass made Spout (nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1174 25.29 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 300mm (nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1175 25.30 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 450mm (nickel plating 0.10 micron and chrome plating 0.3 micron).(Premium Range Sanitary Ware) 1176 25.31 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 600mm (nickel plating 0.10 micron and chrome plating 0.3 micron) .(Premium Range Sanitary Ware) 1177 25.32 Providing and fixing in position best Indian shower rose 300x300mm square body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range Sanitary Ware) 1178 25.33 Providing and fixing in position best Indian shower rose 150mm dia, body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range) 1179 25.34 Providing and fixing in position best Indian shower rose 200mm dia body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles .(Premium Range) 1180 25.35 Providing and fixing in position best Indian shower rose 240mm body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range) 1181 25.36 Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 2- way Bib Cock .(Premium Range) 1182 25.37 Providing and fixing in position best Indian Health Faucet with 8mm dia 1.20 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).(Premium Range Sanitary Ware) 1183 25.38 Providing and fixing in position best Indian Auto Closing Pillar Cockdody with 65 mm extension (with DECOL cartridge) for wash basin use. (Premium Range) 1184 25.39 Providing and fixing in position best Indian Auto Closing Bib Cock with built in control cock wihh wall flange (with DECOL cartridge) for common area use. (Premium Range) 1185 25.40 Providing and fixing in position best Indian Auto Closing Urinal valve open type with built in control cock wihh wall flange (with DECOL cartridge) for urinal use only. (Premium Range) 1186 25.41 Providing and fixing in position best Indian Auto Closing Urinal valve concealed type (with DECOL cartridge) for urinal use only. (Premium Range) 1187 25.42 Providing and fixing in position best Indian Auto Closing wall mounted Pillar Cock (with DECOL cartridge) for wash basin use only. (Premium Range) 1188 25.43 Providing and fixing in position best Indian Auto Closing 40mm Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/ cartridge). (Premium Range) 1189 25.44 Providing and fixing in position best Indian Auto Closing 40mm Dual Flow (3.0/6.0 liter) Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/ cartridge). (Premium Range) 1190 25.45 Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) 1191 25.46 Providing and fixing in position best Indian Sensotronic Sensor Faucet for Wash Basin use only. (Premium Range) 1192 25.47 Providing and fixing in position best Indian Sensotronic Sensor battery & electrical oprated type (9V transformer) Faucet For Urinal use only. (Premium Range) 1193 25.48 Providing and fixing in position best Indian Sensotronic Sensor concealed type Faucet For Wall Mounted Water Closet use only. (Premium Range) 1194 25.49 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 300 mm long. (Premium Range) 1195 25.50 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 600 mm long. (Premium Range) 1196 25.51 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Swivel Towel holder Twin Type. (Premium Range) 1197 25.52 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Ring Square. (Premium Range) 1198 25.53 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dish Holder. (Premium Range) 1199 25.54 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dispenser with Metallic Bottle. (Premium Range) 1200 25.55 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Tumbler Holder. (Premium Range) 1201 25.56 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet paper holder with Flap. (Premium Range) 1202 25.57 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet Roll Holder. (Premium Range) 1203 25.58 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Glass Self-size 600mm with toughened glass (Premium Range) 1204 25.59 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Double coat Hook. (Premium Range) 1205 25.60 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Towel Rake 600 mm. (Premium Range) 1206 25.61 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) W. C. Brush Holder. (Premium Range) 1207 25.62 Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with. (Premium Range) 1208 25.63 Wall Hung Basin: Providing and fixing white vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, C. P. brass single lever basin mixer, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.63.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) 25.63.2 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 570x470x190 mm. (Premium Range) 25.63.3 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 495x400x365 mm. (Premium Range) 25.63.4 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 500x440x385 mm. (Premium Range) 25.63.5 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 635x485x305 mm. (Premium Range) 1209 25.64 Wall Hung Basin ; Providing and fixing white vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, 15 mm C. P. brass pillar cock, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.64.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 635x430x190 mm. (Premium Range) 1210 25.65 Providing and fixing in position best Indian, quarter turn table mounted sink mixer (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1211 25.66 Providing and fixing in position best Indian, quarter turn wall mounted sink cock (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1212 25.67 Shower Glass Cubical: Providing and fixing toughen glass shower enclosure conformed Is 2553 (part 1. 1990) or IS 14900. 2000 or IS 2835.1987 or IS 14450. 2000 with C. P. brass 5 Year warranted hardware, 19mm dia SS 304 grade stabilizer, all plastic Parts of food grade plastic and all glass shall be toughened at 700 degree Celsius and Anti lime scale treated including painting of fittings, cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range) 25.67.1 Providing and fixing corner entry 6 mm toughen glass made to measurement shower enclosure size 1200mm x1200mm x 1950mm with aluminum profile on sides, shower enclosure with door sliding on both sides. (Premium Range) 25.67.2 Providing and fixing 8 mm toughen glass wall to wall sliding shower enclosure with one fixed glass and one silding door with a Towel Rod Fixed on the fixed glass size Hight:2000 mm Width: 1500mm to 2000mm. (Premium Range) 25.67.3 Providing and fixing 8 mm toughen glass made to measurement door Openable (inside/outside) shower enclosure two parts Wall to Wall enclosure with one fixed glass and openable door fixed withwall with square hardware & profile glass size Hight: 2000mm Width 800mm to 1200mm. (Premium Range) 1213 25.68 Providing and fixing 8 mm toughen glass made to measurement door Openable (inside/outside) shower enclosure two parts Wall to Wall enclosure with one fixed glass and openable door fixed with wall with square hardware & profile glass size Hight: 2000mm Width 800mm to 1200mm. (Premium Range) 1214 25.69 providing and fixing white tempered glass showerpenal with special Surface body materials tempered glass with glass special surface PVC back. ABS Movable tops Shower, 4 moveable ABS body massage jets, Hand shower with fiexible hose,Brass Sout, shelf, Thermostatic mixer with diverter, 40 cm stainless steel braided hose, Minimum water pressure required 2 bar. 1215 25.70 Thermostat Mixer : Providing and fixing in position best Indian, concealed high flow bath and shower mixer with thermostatic control cartridge (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1216 25.71 Providing and fixing in position best Indian, exposed wall mounted bath and shower mixer with thermostatic control cartridge with button attachment on spout with connecting legs and wall flange ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) .(Premium Range) 1217 25.72 Providing and fixing in position best indian, eko exposed shower mixer (wall mounted) with thermostatic control cartridge, 115mm long bend pipe on lower side, connecting legs and wall flange (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) . (Premium Range) 1218 25.73 Providing and fixing in position best Indian, exposed shower mixer (tub mounted) with thermostatic control cartridge, with button attachment on spout with straight legs (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1219 25.74 Providing and fixing in position best Indian, 4 - way diverter consisting of concealed body and wall flange for multiple shower working with one shut-off position and 3 outlets for body shower, head shower and spout ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1220 25.75 Providing and fixing in position best Indian, thermostatic concealed high flow control valve with wall flange ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) . (Premium Range) 1221 25.76 Medical Faucets : Providing and fixing in position best indian, single lever surgical purpose elbow action basin mounted mixer with extended Operating lever without popup waste system with 450mm long braided hoses (cartage size32mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn). (Premium Range) 1222 25.77 Providing and fixing in position best Indian, surgical purpose elbow action pillar cock with extended Operating lever.( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) (Premium Range) 1223 25.78 Providing and fixing in position best Indian, surgical purpose elbow action wall mounted pillar cock with extended Operating lever and wall flange. (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn). (Premium Range) 1224 25.79 Providing and fixing in position best Indian, 692mm long, satin finish C. P. Brass grab bar made of 304 grade ss i/c all nuts and screw (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1225 25.80 Providing and fixing in position best Indian, satin finish, C. P. Brass grab bar with left/right 90 degree angle, made of 304 grade ss i/c all nuts and screws. (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1226 25.81 Providing and fixing in position best Indian, C. P. Brass grab bar vertical swing, 304 grade ss made all nuts and screws. (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1227 25.82 Providing and fixing 8mm thick frosted safety glass Urinal partition size 900mm height and 450mm width, fixed with C P brass bracket of appropriate size i/c cutting and making good the wall and floors wherever required with all fittings and fixtures etc. complete.(Premium Range) 1228 27.4 Providing and fixing Stainless steel plate 304 grade of 1.50mm thick, including writing with Embossing of letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer- in-Charge. 1229 27.5 Providing and fixing of name plate for offices name of Stainless steel plate 304 grade of 1.50mm thick, including writing with computerized vinayle sheet letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer- in-Charge. 1230 27.6 Providing and fixing Aluminum composite panels Silver colour with matte finish, 3mm thick, (0.25mm 2.5mm and 0.25mm) sheet for name plate including writing with computerized vinayle sheet letters of required size including fixing at required placed with 1.25m Chromium plated Steel Pipe 15mm dia, compete as per direction of Engineer-in-Charge. 1231 27.7 Providing and fixing Aluminum composite panels Silver colour with matte finish, 3mm thick, (0.25mm 2.5mm and 0.25mm) sheet for name plate including writing with computerized vinayle sheet letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer-in-Charge. 1232 27.8 Providing and fixing stainless steel English (Capital) and Hindi letters in standard pattern bellow type made with 1.20 mm thick stainless steel (ASI Grade- 304 ) Depth of letter shall not be less than 30mm and rate includes welding/soldering of joints polishing, buffing and fixing on the wall, plate and beam surface at any height with necessary nut and bolts/fastener wherever is required complete as per direction of Engineer-in-Charge. 1233 27.10 Providing and fixing of prestressed vertically casted concrete panels (both surfaces should be smooth and having grooves on both faces) of M-40 grade of concrete of size 2100x300x50 mm having minimum 4 nos of high tensile steel wire as per IS 6006:2014 of dia 3 mm placed horizontally in full length of panel with prestressed precast concrete column of M-40 grade of size 3000x150x150 mm having minimum 7 nos of high tensile steel wire as per IS 6006:2014 of dia 3 mm placed vertically in full length to erect precast boundary wall panels to height 2100 mm from GL including excavation of pit of size 750x750x900 mm in all kind of soil except rock for erection of columns and grouting the pit with M-20 grade of concrete. Manufacturing, transportation and installation at site all complete as per the direction of Engineer-in-Charge. 1234 27.11 Extra for every additional height of 0.3 m up to height of wall 3 m 1235 28.35 Providing and fixing of 3 seater stone bench made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1500mm, width 600mm, legs height 500 mm, back support height 500mm. 1236 28.36 Providing and fixing of stone planter (bench) made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1200mm, width 500mm, legs height 500 mm. 1237 28.37 Providing and fixing of stone table made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1000mm, width 600mm, legs height 750 mm. 1238 28.38 Providing and laying C.C. pavement of mix M- 25 with ready mixed concrete from batching plant including centering and shuttering complete. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, with wire brush etc. complete as per specifications and directions of Engineer- in-Charge.Note: Cement content considered in this item is @ 330 kg/cum. 1239 29.1 Preparation of site plan and location plan with total station surveying showing all individual structures and features like trees, roads, culverts, nallas, electric poles, telephone poles, sewer lines, chambers, water supply lines, hand pumps, well etc. complete along with showing location of roads proposed in master plan. i/c Contours of entire area at 0.5 m. intervals using auto level, preparing of site plan in soft copy (using autocad) in suitable scale as desired by engineer-in-charge duly indicating north direction. Rate includes providing 1 digital copy and six hard copies, one print on tracing film, khasra map duly showing the land and location plan (index plan) and google image of the land. Rates are inclusive of transportation charges. (Work shall be got done through consultants duly empanelled with chief Architect MP P.W.D.) 29. 1.1 Upto 1 Hectare 29.1.2 1 Hectare to 2 Hectare 29.1.3 Add extra for each additional one Hectare or part there off 29.1.4 Excavation of trial pit of size 1.20 m X 1.20 m with minimum depth of 0.9 m and maximum depth of 3.5m as directed by the Engineer in Charge. Trial pit shall be taken at suitable location/ locations as directed by Engineer in charge and shall be indicated on the site plan showing details of soil strata. 1240 29.2 Preparation of double line plan after measurement of internal as well as external dimensions of existing buildings/structures and plotting the same in suitable scale as directed by Engineer-in-charge. 1241 29.3 Preparing of double line plan for planning of addition and alteration work after measurement of internal as well as external dimensions and details of existing door window, ventilator openings and partitions, addition /alteration done previously in buildings/structures and plotting the same separately showing sectional elevations (minimum two numbers) and all elevations along with all relevant details like doors, windows stairs etc in suitable scale as directed by Engineer-in-charge. The consultant shall also submit detailed condition survey report. 1242 29.4 Performing Plate Load Test (P.L.T.) for Determining soil bearing capacity (SBC) at site including submission of Geotechnical Report and recommending bearing capacity in accordance with IS-1888-1982 (Without Conveyance). 1243 29.5 Performing Standard Penetration Test for determining soil bearing capacity (SBC) in accordance with IS-2131-1981 and submission of Geotechnical Report on bearing capacity based on SPT in accordance with IS-6403-1981 (Without Conveyance) 1244 29.6 Transportation charges for transportation of Geotechnical testing equipments for plate load test or standard penetration test upto a distance of 100km. (upto 100km going and 100km returning from district H.Q. both way) Rates are inclusive of Loading and unloading of testing equipments and other incidental charges during both journeys to be paid only once for one set (separate for PLT or SPT) of testing. 29.6.1 Up to 100km (both way) 29.6.2 Add extra for distance beyond 100km and upto 150km. (both way) 29.6.3 Add extra for every additional km beyond 150km (both way) 1245 29.7 Preparation of detailed estimate on the basis of the working drawing supplied by the department and current SOR applicable, including computation of bill of quantities (BOQ) of material and supplying the same in six hard copies and one soft copy to the Engineer-in-Charge and if required revision of the same without any additional charges. (Work shall be got done through consultants duly empanelled with chief Architect MP P.W.D.) The estimate shall be prepared only in standard format prescribed as per appendix 14 of this SOR. 1246 29.8 Preparation of DPR including site visit to verify contours & soil reports and preparation of master plan of campus including architectural working drawings and estimates in prescribed format as per appendix 14 of this SOR to obtain AA; and there after architectural drawings for statutory approvals and detail drawings at construction stage; and as constructed drawings on completion of work the DPR. Bifurcation of professional fee payable in stages as per this item shall be in accordance with List-1, List-2 & List-3. Given in preambles of this chapter 3.All work such as preparation of DPR, working drawings, statuary drawings, details drawings and as constructed drawings shall be done by the same architect/consultant to ensure consistency in services, even if time required to complete all stages as per Activity sheet exceeds the contract period. 1247 29.9 Preparation of the structure design & drawings by a structural engineer empanelled with the Chief Architect MP PWD on the basis of architectural drawings supplied/approved by the department, in accordance with relevant codes/manuals and according to the Terms & Conditions, prescribed in Activity Sheet No-1, List-4 given in Annexure-14 appended with SOR. Design and drawing shall also include ‘Tables’ for the bar-bending schedules (BBS) and concrete/steel consumption. The design and drawing shall be submitted to the Engineer-in-Charge in six hard copies and one soft copy for execution. The payment shall be done in accordance with relevant stage in activity sheet and list. 29.9.1 First time design work 29.9.1.1 Built up area upto 500 sqm 29.9.1.2 Built up area more than 500 sqm and upto 3000 sqm 29.9.1.3 Built up area more than 3000 sqm. 29.9.2 Repetition of structural design of a structural design done by the structural himself or by any other structural engineer at different site, where S.B.C. or seismic zone is different.(only plinth area payment to be paid) 29.9.2.1 Plinth area upto 500 sqm 29.9.2.2 Plinth area more than 500 sqm and upto 3000 sqm 29.9.2.3 Plinth area more than 3000 sqm 1248 29.10 Assessment of load carrying capacity and structural soundness of existing building mainly comprising of R.C.C. structure using existing information such a existing drawing, design and footing details, if available. The consultant shall carry out destructive/non destructive testing of structure at site including site investigation which may require opening of footings by digging adjoining ground fill and restore backfill structure after testing is done. This work shall be performed by a structural engineer (proof checking) empanelled with the chief Architect MP PWD Bhopal or any government engineering college. The rate shall include all charges for labour, testing, consultation of geotechnical consultant and site visit to carry out site testing Per Sqm (built up area of wing/block of existing building where construction is proposed). 1249 29.11 Drafting structural drawing on the basis of the structural design supplied by the department in accordance with all relevant codes/manuals and as per IS: 1893- 2002 and IS: 13920-1993 with updation. The work shall include making revision/compliance if any and obtaining approval of drafting work, without any additional cost within time specified by the Engineer-in-Charge or from the competent authority. The drawings for approval shall be submitted to the Engineer- in- Charge in two hard copies (minimum size A-2) and there after fair drawings on 100 micron film along with seven copies of amonia prints (minimum size A-1) and one soft copy. Drawings shall be stamped and signed with the statement that Drafted by me as per structural design done or got done by the department. Note:- This work can be done only through a person having qualification of Diploma in civil engineering/BE (civil engineering) and having certificate in AutoCAD issued by AutoDesk or by its authorized institution.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Madhya Pradesh View Result →
47.
Housing Urban and Rular Development #9761300 Technical Bid
Maintenance of Drain (Repair, Raising And Covering Of Main Darin Along Sector-67 On 60Mtr. Wide Kailash Road) Noida - Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.. All kinds of soil. The contrector has to detect different utilites like sewer line water supply line elecctric cable telephone cable gas pipe line etc. using utility detectingmachine before start of excavetion andshall start excavetion only after getting permissionof Engineer -in Charge . 2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 100 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 3 12 mm cement plaster of mix :1:4 (1 cement : 4 coarse sand) 4 Neat cement punning 5 Fabrication & Manufacturing of Prestressed Hollow Core slab (Hollow area 25 to 30%) of different thickness & modular width 1200 mm in Controlled Factory Environment with approved methodology informing to IS 10297- 1982 conforming to IS : 10297- 1982 by using long line casting method having arrangement of proper steel bed. Concreting should be done by batch mixing plant capable of producing zero slump concrete, transported through automatic shuttels of standard make & layed on bed with the help of extruder/Slipformer, finishing, curing and also provision of steam curing. Cutting, making necessary cutout/holes of required sizes for services in slab element after achieving required strength, yard handling & stacking all complete as per approved shop drawings & design mix as per the direction of the Engineer-in-charge. (Cost of strands should be paid separately). Note : Excess/ less cement over the specified cement content used as per design mix is payable / recoverable separately 150 mm thick hollow core slab 6 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 7 Supply of Mobile Hydraulic Crane 35 Tonne Capacity (173 HP) in all respect as per direction of Engineering in Charge. 8 Dewatring Pump 10 HP at site on hire bases including cost of diesel and driver etc complete in all respect as per direction of engineer in charge. 9 Empty bag filling by sand: Supply and laying fo sandy earth plastic cement bags (Volume 0.035 cum) including cost fo earth cost of empty bags, labour, stitching with sututely complete, laying and placing complete at the place of restoration of embankment.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
Uttar Pradesh View Result →
48.
Defence #9749554 AOC
Tender For Provision Of Klp For Sig Coy At Lalgarh Jattan Mil Station.; 2 Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I(Ref pre-priced schedule attached separately) 3 Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately) 4 Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately) 5 Lump sum price worked out by the tenderer for ROAD, PATH, HARD STANDING AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately) 6 Lump sum price worked out by the tenderer for AREA DRAINAGE AND FOUNTAIN WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately) 7 Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately) 8 Lump sum price worked out by the tenderer for SECURITY WALL, FENCING AND GATE WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately) 9 Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately) 10 Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION AND LIGHTENING PROTECTION as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately) 11 Lump sum price worked out by the tenderer for SUMMER COOLING APPLIANCES, AIR CONDITIONING AND HOT WATER SUPPLY as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately) 12 Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately) 13 Lump sum price worked out by the tenderer for DEMOLITION AND DISMANTLING as listed in Schedule ‘A’ Part-XII(Ref pre-priced schedule attached separately) 14 Schedule A Part-XIII(FURNITURE) 15 Almirah small steel as per drawing No. FD-1032 sheet No. 1/1 16 Almirah large steel as per drawing No. FD-1031 sheet No. 1/1 17 Locker (built-in) (steel) as per drawing No. FD-1029 sheet Nos 1/2 & 2/2 18 Work bench workshop (1800 mm X 900 mm X 760 mm) (steel) as per drawing No. FD-1024 sheet No. 1/1 19 Book case (steel) as per drawing No. FD-1028 sheet No. 1/1 20 Bath Mat (PVC) as per drawing No. FD/E6/MAP/07 sheet No. 1/1 21 Barber Chair with adjustable Headrest as per Model No. IK-2687 of Ikonic Furniture/ Professional or equivalent of Marc Salon Furniture 22 Chair easy per drawing No. FD-229 sheet No. 1/1 23 Chair easy as per drawing No. FD-358 sheet No. 1/1 24 Chair writing as per drawing No. FD-280 sheet No. 1/1 25 Chair wooden bottom without arms as per drawing No. FD-285 sheet No. 1/1 26 Chair dining as per drawing No. FD-279 sheet No. 1/1 27 Revolving Chair of Make:- Geeken, Model No:- GB-401 or equivalent of Methodex, Godrej as approved by the GE 28 Charpoy with hard top as per drawing No. FD/MAP-II/01 sheet No. 1/1 29 Desk with Dias Wooden as per drawing No. FD-399 sheet Nos 1/2 and 2/2 30 Board Notice/Display Board of size (900 mm X 1200 mm) of Make:- Alkosign, Model No:- ASGPB 90120 or other equilent make as approved by the GE 31 Drugget of variety No. Wollen, 60 tex X 12 warp, size 3000 mm X 2000 mm as per IS 697: 2005 32 Form with back (1800 mm long) as per drawing No. FD-78(M) sheet No. 1/1 33 Form without back(1525 mm long) (steel) as per FD-1027 sheet No. 1/1 34 Hat stand with mirror (large) as per drawing No. FD-362 sheet No. 1/1 35 Hot case small as per drawing No. FD-363 sheet No. 1/1 36 Ladder aluminium as per drawing No. FD-1025 sheet No. 1/1 37 Mirror (1200 mm X 1200 mm) 38 Pointer short 900 mm as per drawing No. FD-1041 sheet No. 1/1 39 Pointer medium 1220 mm as per drawing No. FD-1041 sheet No. 1/1 40 Pointer long 1525 mm as per drawing No. FD-1041 sheet No. 1/1 41 Receptacle as per drawing No. FD/E6/MAP/13 sheet No. 1/1 42 Side rack with tray three spaces (steel) as per FD-1023 Sheet No. 1/1 43 Sofa set single seater as per drawing No. FD/MAP-II/02 sheet Nos 1/2 & 2/2 44 Sofa set 5 seaters (3 + 1 + 1) as per drawing No. FD/MAP-II/02 sheet Nos 1/2 & 2/2 45 Stool steel (510 mm high) as per drawing No. FD-409 sheet No. 1/1 46 Stool 305 mm X 305 mm X 760 mm (steel) as per drawing No. FD-81(M) sheet No. 1/1 47 Meat safe as per drawing No. FD-47(M) sheet No. 1/1 48 Table clerks (steel) as per drawing No. FD-1004 sheet No. 1/1 49 Table officers (steel) as per drawing No. FD-1003 sheet Nos 1/2 & 2/2 50 Table marble top (1530 mm X 900 mm X 760 mm) as per drawing No. FD-298 sheet No. 1/1 51 Table dining 6 persons as per drawing No. FD/MAP-II/03 sheet No. 1/1 52 Table with drawer (900 mm X 600 mm X 760 mm) (steel) as per drawing No. FD-1008 sheet Nos 1/2 & 2/2 53 Table for Havs & Ors (steel) as drawing No. FD-1007 sheet No. 1/1 54 Table (600 mm X 600 mm X 760 mm) as per drawing No. FD-293 sheet No. 1/1 55 Table centre two tier (900 mm X 450 mm X 400 mm) as per drawing No. FD-274 sheet No. 1/1 56 Table centre as per drawing No. FD-375 sheet No. 1/1 57 Teapoy as per drawing No. FD-278 sheet No. 1/1 58 Schedule A Part-XIV(ARBORICULTURE) 59 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Ashoka Regional of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 60 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Azadirachta indica ( Neem ) plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 61 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Jamun of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 62 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Peepal plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 63 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Shesham plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 64 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Mahogany plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 65 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Gulmoharplant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 66 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Keenu of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 67 M & L for preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete all as specified and as directed. Note: Cost of sludge, manure or extra earth to be paid for separately. 68 M& L for plantation of shrubs, hedge etc. at the site including watering and removal of unserviceable material including shrub/ hedge plants of any type and of height 60-75 cm in earthen pots of size 20 cm complete all as specified and as directed. 69 M & L for trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure) complete all as specified and as directed. 70 Supplying and stacking at site dump manure screened through sieve of IS. designation 20 mm from approved source, including carriage from outside MD land complete all as specified and as directed. Note: Manure measured in stacks will be reduced by 8% for payment. 71 M & L for rough dressing the trenched ground including breaking clods complete all as specified and as directed. 72 M & L for uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation complete all as specified and as directed. 73 M & L for fine dressing of the ground complete all as specified and as directed. 74 M & L for spreading of sludge, dump manure and/or good earth in required thickness complete all as specified and as directed. Note: Cost of sludge, dump manure and/ or good earth to be paid separately. 75 M & L for grassing with selection No. 1 grass in rows 5 cm apart in both directions including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth complete all as specified and as directed. Note: The earth shall be paid for separately. 76 Schedule A Part-XV(MISCELLANEOUS PARTS) 77 S & F in integrated type Heat Pump water heater with following components including installation testing and commissioning Outdoor Air cooled Integrated or split type Heat Pump with recirculation mode having minimum compressor capacity 3 HP, hermetically sealed with environment friendly refrigerant. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. The ratio of Rated output heating capacity to Rated Input Power should be such that COP of the machine is not less than 3.0 and must have Back-up heater power of not less than 12 kW and rated power input of not more than 2.5 kW. The heat pump shall have water storage tank of capacity (having internal glass lining) not less than 450 litre. NOTE: (a) Heat pump should have all the safety protections like high/low voltage, high temperature, refrigerant leak, compressor overheat protection with operational noise level not more than 60 dbA. (b) Heat pump should have a user friendly control panel to set the desired temperature with display of the actual temp also with flexibility of installing the same 15-30 m away from the heat pump. 78 Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner cooling type both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, ISEER 5, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 1.5 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class O Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8 for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 year for compressor, 5 year for condenser and PCB card after Installation and commissioning of complete unit. 79 Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner cooling type both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, ISEER 5, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 2 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class O Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8 for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 years for compressor, 5 years for condenser and PCB card after Installation and commissioning of complete unit. 80 Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 195 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed. 81 Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 5 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. 82 Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 4 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. 83 Supplying, fixing, testing and commissioning Industrial cooler (evaporative cooling unit), minimum dia 900 mm, minimum airflow 20000 cum per hour, Axial fan type, Noise maximum 70 decibel, coverage area 100 to 200 sqm, water consumption 65 to 90 liter, UV protected cooler body including 36-liter water tank, standard duct with auto swing grills with all fixing arrangements complete all as specified and as directed. Note: - Industrial sockets and three phase control copper wires shall be measured and paid separately. 84 Supplying, fixing, testing and commissioning Industrial cooler (evaporative cooling unit), minimum dia 900 mm, minimum airflow 15000 cum per hour, Axial fan type, Noise maximum 70 decibel, coverage area 100 to 200 sqm, water consumption 65 to 90 liter, UV protected cooler body including 36-liter water tank, standard duct with auto swing grills with all fixing arrangements complete all as specified and as directed. Note: - Industrial sockets and three phase control copper wires shall be measured and paid separately. 85 Supply, assembly and erection of stainless steel (SS-304 grade) of 0.8mm thick rectangular duct (for industrial cooler) jointed by TIG/MIG welding or riveted with SS flanges with neoprene gasket at joint, supports of MS angle iron or SS rods complete all as specified and as directed. Note: The design of the duct for industrial cooler shall be submitted by the contractor for the approval of the GE. 86 Disconnecting all existing connection including earth wire with transformer of capacity 200 kVA upto and including 315 kVA installed on plinth or 2 poles or 4 poles structures and taking down and shifting transformer from any substation under the GE to new location with help of Hydra (Recovery)/JCB/ Crane etc. and including installation installed on plinth or 2 poles or 4 poles structures at new location including connecting all connections, earthing, conductors, cables, nuts, bolts, washers etc. complete all as specified and as directed. 87 Construction of platform for transformer having dimension (2000 mm X 2000 mm), height 2000 mm and foundation depth of 1200 mm including necessary earthworks in any type of soil, 150 mm moorum filling in foundation, 150 mm PCC foundation with M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate, brick work with sub class B bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick externally in two coats of (15 mm and 5 mm) in cement mortar 1:4, enclosed spaces filled with moorum, 75 mm PCC subbase of flooring with M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate, 150 mm PCC flooring with M10(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash complete all as specified and as directed. 88 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 630 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 630 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 400 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 320 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 160 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (c) MCB, TPN, 10 kA, C-type, rated current 32 A: -1 No (d) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -4 Nos 89 Srl Item No 15.012 Continued......(E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 4 Nos (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 pole contactor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with 10 sqmm copper wiring, IP54 protection grade- 1 No (G) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 90 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 400 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 400 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 320 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 160 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 100 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (c) MCB, TPN, 10 kA, C-type, rated current 32 A: -2 Nos (d) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -6 Nos 91 Srl Item No 15.013 Continued......(E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 92 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 160 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 100 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (b) MCB, TPN, 10 kA, C-type, rated current 32 A: -1 No (c) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -9 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-100 Amps with CT and selector switch – 1 No 93 Srl Item No 15.014 Continued......(c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 94 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 160 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 100 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCB, TPN, 10 kA, C-type, rated current 32 A: -4 Nos (c) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -1 No (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No 95 Srl Item No 15.015 Continued......(c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 96 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 150 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 150 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 100 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCB, TPN, 10 kA, C-type, rated current 32 A: -2 Nos (b) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -7 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT 97 Srl Item No 15.016 Continued......(F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 98 M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed. 99 M & L for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 10 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. 100 Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 63 mm, minimum inside dia 47 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. 101 Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 110 mm, minimum inside dia 82 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. 102 Supply and erect factory made 7 meter long hot dip galvanized (as per relevant IS with average coating thickness 65 micron) octagonal poles conform to IS-2062/ BSEN 10025 with 155 mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet along with foundation type base plate of size 250 mm X 250 mm X 16 mm, foundation bolt 4 Nos of M20 X 600 mm high J type EN8 grade, including 1 meter long hot dip galvanized single arm (swan neck) bracket made up of 40 NB dia GI pipe and including excavation, earth work, PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturer’s instructions including marking pole number in letters & figures of size not less than 10 cm height with red colour enamel paint complete all as specified and as directed. Note: - (i) Srl number will be issued by Engineer-in-Charge. 103 Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 2.5 sqmm cable, one run of 2.5 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 104 Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 100 and nominal outside dia 110 mm as per IS 4984: 2016 including all fittings and fixtures in trenches complete all as specified and as directed. 105 Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 100 and nominal outside dia 90 mm as per IS 4984: 2016 including all fittings and fixtures in trenches complete all as specified and as directed. 106 S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed. 107 S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 200, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed. 108 S & F factory made rubber coated cement concrete paver block 60 mm thick (M35 grade with minimum compressive strength of 35 N/mm2), manufactured using cement, graded coarse aggregate, , fine aggregates and synthetic rubber layer of 5mm thickness, of approved shape and size (typically 200 mm X 100 mm or equivalent) in approved colour with smooth antiskid finish having, water absorption not more than 6%, abrasion not more than 2% and high slip resistance and in accordance with the provision of IS 15658:2006, IS 10262: 2019, IS 456: 2000, IS 2308 (Pt-l to VIII) and IS 1199: 1959 and laid over 30 mm thick average sand bed , filling joints with fine sand, complete all as specified and directed. 109 Material and labour for construction and laying of kerb of size as directed directly on the road construction site with automatic kerb casting machine (kerb/divider making/laying machine), using M25 (Design Mix) grade cement concrete laid in position to the required line, level and curvature kerb stone cast continuous and making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) at a distance as directed, including making drainage opening wherever required, including necessary excavation/earth work and making good disturbed surface complete all as specified and as directed. 110 Material & Labour for providing and fixing stainless steel (grade X 02Cr19Ni1O, 304 S2, surface finish No. 4 as per IS 6911: 2017) gate made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. 111 Supply and fix punched tape concertina coil made out of cold drawn unalloyed steel wires of dia 2.6 mm having minimum tensile strength of 1670 N per sqmm as per IS 4454 (Part- 1): 2001 with hot dip galvanized as per practice recommended in IS: 2629 and the coatings shall conform to heavily coated hard variety as per table I of IS: 4826 (weight of Zinc coating 230 gram per sqm minimum) and steel strip of size 19 mm X 0.5 mm with hardness of 137 to 187 VPN and zinc coating of 18 to 20 microns, minimum 610 mm dia of coil when closed, (9 kg ± 5 %) weight of coil with 50 turns & 129 Nos clips (without handles and spikes) and minimum 580 mm dia when opened upto 6 metres, stretched to 6 metres for 50 turns during installations complete all as specified and as directed. 112 M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 113 M & L for point wiring for one 3 pin/ 5 pin/ 6 pin 5/15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 114 M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 115 M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 116 M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 117 S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 6 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 118 S & F TPN distribution board 4 way vertical type double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper busbar of suitable rating, with neutral bar and earth bar and cable tie for cable management, IP54 Protection and provision and including MCCB 4 pole upto 160 Amp,16KA as incomer and provision for MCBs as outgoing, dust and vermin proof complete as per IEC61439-3 complete all as specified and as directed. Note: MCBs for outgoing shall be measured and paid separately. 119 S & F blanking plate in DBs of MCB complete all as specified and as directed. 120 Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 121 Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 122 Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 10 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 10 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 10 sqmm cable, two runs of 10 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 123 S & F LED bulb, System Wattage: 9 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed. 124 S & F LED bulb, System Wattage: 0.5 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed. 125 Supply, fixing and testing LED batten with battery/Invertor, LED Rating (in Watts)/System Wattage/Rated Power: 20 Watt, Rated Voltage & Frequency: 230V, 50Hz, Luminaire System Efficacy (Lumen/watt): 100, Operating Voltage Range: 140-280V, Power Factor: ≥0.95, Total Harmonic Distortion: ≤30%, Colour Rendering Index(CRI): ≥80, Colour Temperature: 5000⁰-6500⁰ Kelvin, Driver Efficiency: ≥85%, Emergency Time: 3 hour, Ingress Protection: IP-20, Type of Control Gears: Electronic, Working life for LED (as per LM-80 and LM 21 reports): ≥50000 hours, Housing Material: Aluminium Extruded, Front Cover Material: Polycarbonate, Surge Protection of 3.0 kV Internal: Yes, Open & Short Circuit Protection: Yes, Reverse Polarity Protection: Yes, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Emergency Light Output (Lumen %): 50, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 126 Supplying, installing, testing and commission of commercial kitchen stainless steel exhaust, chimney/ hood system having the following components: - (a) Commercial kitchen stainless steel hood (6 feet long/ 2.8 feet wide) of stainless steel 304 grade, double filter absorber type, rust free grade steel, inbuilt with automatic sensor as per OEM specifications. (b) Automatic mode changer (drift air), turbo force 5 HP motor with bird screen for protection against bird and foreign materials, rust free body and plates, automatic shutter function complete metal body (c) Double coated high grade ducting material 40 feet long, high quality material as per OEM specifications Note: The contractor shall design the ducting portion as per the drawings and room capacity of kitchen portion of the drawings and calculate the requirement of ducting and submit the design to the GE for approval. The quoted rate shall be inclusive of all these aspects. 127 S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves, two ways in double control with wall flange, made of cast brass including knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. 128 S & F single lever concealed divertor including bath spout and shower complete all as specified and as directed. 129 S & F 15 mm wash basin mixture, centre hole, mixing hot & cold water, fancy type, cast copper alloy, chromium plated with capstan head, chromium plated, screwed down high pressure, screwed for iron pipe etc and fixed in repairs complete all as specified and directed by engineer in charge. Make : Jaquar Cat No: 5001B or equivalent as approved by the GE. 130 S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed. 131 Supply, installation, testing & Commissioning of Mechanical type incinerator electrically operated, made of galvanised iron of capacity 50 Kg/hour suitable for burning including shredder complete all as specified and as directed. 132 S & F factory made rubber coated cement concrete paver block 80 mm thick (M40 grade with minimum compressive strength of 35 N/mm2), manufactured using cement, graded coarse aggregate, , fine aggregates and synthetic rubber layer of 5mm thickness, of approved shape and size (typically 200 mm X 100 mm or equivalent) in approved colour with smooth antiskid finish having, water absorption not more than 6%, abrasion not more than 2% and high slip resistance and in accordance with the provision of IS 15658:2006, IS 10262: 2019, IS 456: 2000, IS 2308 (Pt-l to VIII) and IS 1199: 1959 and laid over 30 mm thick average sand bed , filling joints with fine sand, complete all as specified and directed. 133 S & F glass mosaic tiles , thickness 4 to 5 mm on floor and on vertical surfaces with Type 3 adhesive as per IS 15477: 2019, in a bed of an adhesive average thickness not less than 6 mm and not exceeding average 12 mm in final bed thickness complete all as specified and as directed. 134 Supplying, installing, testing and commissioning outdoor type compact substation (CSS), factory assembled (non walk type) having 11 kV, 630 Amps, internal arc fault for 20KA for 1 sec as per IEC 61330/62271-200 and comprising as under: - (A) MV COMPARTMENT: 11 KV, 630A, 25KA/3 Sec indoor type non-extensible, SF6 gas insulated Ring Main unit with sealed pressure system criterion in accordance with the IEC: 60298,62271 - 202.IAC category IAC-AFL. The Switchgear includes the following HV cubicles The indoor non -extensible SF6 insulated RMU fully motorised consist of 1No. Vaccum Circuit Breaker with Riser (ICOG type) with self-powered relay for protection of transformer (a) Rated voltage should be - 12 kV (b) Rated power frequenecy voltage - 28 kV (c) Rated lightening withstand voltage - 75 kV (d) Rated current for Ring main feeder - 630 amps (e) Rated current for LBS feeder - 630 amps (f) Rated short time current - 25 kA / 3 sec (g) Rated short time making current -50 kA (h) Ambient temperature (0 deg C to + 50 deg C) (i) Rated internal arc rating - 20 KA for 1 sec for tank and cable box category IAC-AFLR (j) RMU shall be provided with protection CTs rated for 30 / 1amps, class - 10P10 accuracy , 2.5 VA burdan for circuit breaker (k) The feeder shall be self-powered/powered by external source and shall be provided with OC+EF protection for transformer and shall have serial port for communication on modbus protocol. (l) Dead short Circuit life of VI - 40 No 135 Srl Item No 15.053 Continued......(B) TRANSFORMER COMPARTMENT: Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 250 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available. (C) LV COMPARTMENT: The LV compartment with Degree of protection-IP54 designed for a 50-degree C ambient temperature. The panel is modular, dead front, freestanding, floor mounted and comprises the following equipment : - (a) 1000 Amps, 50kA withstand fault level capacity rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection (b) Air Circuit Breaker (ACB) of rated current 630 A, Rated operational voltage 415 V, Rated insulation voltage 1000 V, 4 Pole, 50 Hz AC supply, Rated ultimate short circuit breaking capacity 50 kA, Rated service short circuit breaking capacity 50 kA, Rated short time withstand capacity 50 kA for 1 second, Rated making capacity 105 kA, Rated impulse withstand voltage of main circuit 8 kV, typical opening time 40 ms, typical closing time 60 ms, thermal magnetic release, manual draw out, overload protection, short circuit protection, earth fault protection (Incomer) (c) Outgoing – (i) 320A, 4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics=25kA - 1 No, (ii) 160A,4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics-=25kA - 1 No, (iii) MCB TPN, 32 Amp, 10 kA- 01 (iv) MCB SPN, 10 kA, 6 to 32 Amos – 4 Nos 136 Srl Item No 15.053 Continued......(d) APFC Panel: Designing, manufacturing, supplying, fixing, erecting, testing and commissioning LT APFC panel with capacitor bank, conforming to IS 16636: 2017, 100 kVAR, outdoor installations, rated system voltage of the panel 440 V ± 10%, rated frequency 50 Hz, 3 phase, 4 wire, delta connected, rated impulse withstand voltage 8 kV, free standing, pedestal mounted, made of cold rolled close annealed sheet of minimum 2 mm thick for the load bearing structure and minimum 1.6 mm thick for door and partition, 50⁰C ambient temperature, IP 54 Ingress Protection, 500 Amp rated copper busbar, metallized polypropylene (MPP) dielectric type, resin filled box type, self-healing type, shunt capacitor as per IS 13340: 2012, switching configuration: 50 kVAR X 1 No + 25 kVAR X 1 No + 10 kVAR X 2 Nos + 5 kVAR X 1 No (total five steps), suitable protection in line with IEC and IS for overheating, over current, earth fault, over voltage, short circuit, thermal overload and over pressure, suitable size power and control cable as per Indian Standards, powder coated in grey colour, including microprocessor based automatic power factor correction controller with human machine interface, cooling fans, capacitor duty contactors, 7% detuned reactors, two earth terminals in the panel and as per the details mentioned below complete all as specified and as directed. and shall be including the followings: - (I) INCOMING: (i) MCCB rated current(In): 250A, ultimate short circuit breaking capacity (Icu): 50 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, suitable for 415 V, 50 Hz AC supply – 1 No (ii) Microprocessor based automatic power factor correction controller (minimum 5 steps)- 1 No (iii) Cooling Fans to be provided for forced cooling (II) OUTGOING: (a) (i) 5 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No 137 Srl Item No 15.053 Continued......(ii) MCCB rated current(In): 15A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 5 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 5 kVAR 7% detuned reactor copper wound – 1 No (b) (i) 10 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 2 Nos (ii) MCCB rated current(In): 20 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 2 Nos (iii) 10 kVAR capacitor duty contactors – 2 Nos (iv) ON indication lamp – 2 Nos (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 4 Nos (vi) 10 kVAR 7% detuned reactor copper wound – 2 Nos (c) (i) 25 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 50 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 25 kVAR capacitor duty contactors – 1 No 138 Srl Item No 15.053 Continued......(iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 25 kVAR 7% detuned reactor copper wound – 1 No (d) (i) 50 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 100 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 50 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 No (vi) 50 kVAR 7% detuned reactor copper wound – 1 No Note: (a) The kVAR rating of capacitor mentioned is for rated voltage of 440 V. However, the capacitor shall be provided for rated voltage of 480 V by enhancing the kVAR rating suitably. 139 Srl Item No 15.053 Continued......Outdoor Enclosure:- The enclosure shall be made of 2.0 mm thickness Galvanized Sheet Steel tropicalized to meet Indian weather conditions including all the partition sheets & doors. The base of the enclosure shall be of 4.0 mm thickness Hot Dip Galvanized Sheet Steel to ensure rigidity for easy transport & installation. The entire Package Substation shall be Factory Assemble & Factory Fitted. The enclosure shall have IP54 degree of protection for HT & LT switchgear compartment IP34 degree of protection for Transformer compartment. The Enclosure to be tested for Internal Arc fault test to the tune of at least 20 kA for 1 second adhering to as per latest IEC 62271-202.The temperature rise test on enclosure for K10 class. The enclosure exterior shall be powder courted. Only OEM make of CSS is acceptable. The compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. The enclosure, RMU and LV Breaker should be of same make for better co-ordination and Note:- Platform to be made as OEM recommendation is including in this quoted rate. (D) ACCESSORIES: (a) Multifunctional meter digital type of adequate capacity showing voltage, current, frequency, power factor, Kilo watt, Kilo watt hour with inbuilt selector switch with current transformer coils for three phase: - 1 No (b) LED indicating lamps (c) Danger Notice Plates for HT & LT 140 S & F telephone socket outlet including metal box complete all as specified and as directed. 141 S & F 1 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed. 142 S & F television antenna socket outlet including metal box complete all as specified and as directed. 143 S & F co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed. 144 M & L for construction of new valve pit/chamber of size 900 mm (Length) X 900 mm (Breadth) X 900 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class B bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. 145 M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 146 Supplying, laying, installing, testing and commissioning cable laying protection U shape tray of size 100 mm height and 300 mm width, made out of hot dip galvanised iron sheet of 2 mm thick including fixing accessories like cross over, bolt in partition, snap in position, supporting corner, horizontal bend, low elbow, rising elbow, T-piece, tray cover, edge protection, full threaded rod, slotted U channel, round head square neck bolt, flange nut, hinged joiner, screws, fastener, hook, nut, bolt, washer etc. complete all as specified and as directed. 147 Supply, installing, commissioning and testing of washing machine with washer extractor of capacity 60 kg (dry weight per washing cycle) front loading electrically driven including water connection from PVC tank to washing machine as per requirement and drain out pipe from machine to drain complete all as specified and as directed and comprising of following specifications/ accessories/capacity/size and material shall be as per OEM/Manufacturer recommendations: - (i) Industrial washer extractor. (ii)Outer drum/ Inner basket/ outer basket made out of high grade stainless steel sheet of SS304 grade with perforation. (iii) Front loading and unloading open pocket. (iv) Forward and reverse basket rotation. (v) 01 No Heavy duty high spin single phase motor, variable frequency drive type of suitable capacity and 01 Nos driver motor three phase 415 volts variable frequency drive type of suitable capacity. (vi) Suspension with shock absorber and springs. (vii) Fully programmable microprocessor and auto balance while extraction. (viii) Manual dosage of powder detergent. (ix) Door limits electric inter locking and emergency stop for safety and trouble free and operation both manual and auto lock. (x) Aluminium casted pulley and belt. (xi)Main body of full stainless steel 304 grade. (xii)Heater of suitable KW. (xiii) PCC foundation as required shall be as per manufacturers recommendation NOTE: - (a) Contractor shall submit necessary company test certificate and purchase voucher and warranty cards as per recommendation by vender. (b) Testing and commissioning shall be carried out by authorized rep of the firm/company for which no extra payment shall be made. 148 Supply, installing, commissioning and testing of drying tumbler electrically heated suitable for washing machine as per above item having loading capacity of 60 kg per charge Fin type Electric Heater of 48 Kw made out of SS pipe, front loading type, Auto Timed, Auto reveres, Microprocessor controlled with electric motor and electric panel complete. Fully die pressed door, inner basket stainless steel basket of min 503 litre volume, outer body mild steel sheet insulated with glass wool complete all as specified and directed. Note: - (a) The Contractor shall submit necessary company test certificate and purchase voucher and warranty cards as per recommended by vender. (b) Testing and commissioning shall be carried out by authorized rep of the firm/ company for which no extra payment shall be made. 149 S & F stainless steel (SS-304 grade) air grills for air swing and wider coverage complete all as specified and as directed.
Contract Date: Mar 05, 2026 Contract Value : 14.47 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Contract Date: Ref. Documents Contract Value : 20,000
Statutory Bodies & Commissions/Committees No of Bidders 5
West Bengal View Result →
TenderDetail
Loading tenders