View Bid Results For Technical Audit Tenders

We found 182 Bid Results related to technical audit tenders. You can find Contractor details who won technical audit tenders along with contract details in Bid awards announcements section.

Filters
Stage
131
31
20
Tender Publishing Platform
68
114
State / UT
25
27
24
23
16
13
10
7
6
6
6
5
5
5
4
4
4
3
3
3
2
2
1
1
1
1
Contract Value
68
51
44
18
Publish Date
1
0
0
0
0
Sector
24
26
25
19
19
18
14
11
10
9
5
4
4
3
3
2
2
1
1
1
1
1
1
1
1
Ownership
5
84
43
35
18
2
Within keyword
Active filters:
Showing 1–4 of 182 tenders matching your filters
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
2.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Contract Date: Jun 18, 2026 Contract Value : 1.18 Crore
Government Departments No of Bidders 1
6.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
10.
Health and Family Welfare #11036404 AOC
NOTICE INVITING RE E-TENDER FOR PROCUREMENT OF SOME CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC) Group-I Re E-Tender For Procurement Of Some Consumable Items For Two Years From The Date Of Award Of Contract (Aoc) , Cardiac Catheter Introducer Sheath With Needle ( Radial)- 4Fr/5Fr/6Fr, Sheath Length -7.0Cm. Sheath Wire-0.025Cm * 45Cm , Cto Coronary Angioplasty (Ptca)Guide Wire Wires: Subcategories With Different Tip Loads: Hydrophobic/Hydrophilic , Hydrophilic Guide Wire, Nitinol Core With Hydrophilic Coated, Standard Exchange Length-260 Cm, Straight Tip & “J”, Dia-0.18 “ To 0.38” , Transvenous Temporary Pacing Catheter. Size : 5,6 & 7Fr. • Should Be Wovan Dacron Constructed Catheter. • Platinum Tip Electrode Lead. , Plasma Filter For Plasmapheresis , Epidural Kit For Paediatric : Complete Epidural Kit Wit Epidural Catheter 72Cm/90Cm & 24G/22G Made Of Polyamide + Plyurethane Having 3/6 Lateral Eyes, 3 Embedded Line For X Ray Visibility, Tuhey Needles, 0.2 Micron Filter, Lor Syringe And Pin Pad. , Catheter Double Lumen Internal Jugular Curved/Straight 10Fr. , Catheter. Umbilical Catheter { For New Born } All Size,With Female Flexible Mount ,Open Tip Should Be Soft, Rounded,Atraumatic ,Length 40 Cm , Dialyzer High Flux (F60s/Hf80s/Hdf100s) For Hdf Specification : 1. Surface Area-1.3M2 To 1.8M2 2.Blood Priming Volume-80 Ml To 110 Ml. 3. Uf-Co-Efficient-40Ml/Hr/Mmhg To 55Ml/Hr/Mmhg 4. Maximum Tmp-500 Mm/Hg To 600 Mm/Hg 5. Dialyser Membrane-Polysulfone 6. Sterilization Method-Inline Serilization , Dialyzer Single Use For Sero Positive (Low Flux Dialyzer) Specification : 1. Surface Area-1.3M2 To 1.6M2 2.Blood Priming Volume-64 Ml To 90 Ml. 3. Uf-Co-Efficient-12Ml/Hrs/Mm Hg To 16Ml/Hrs/Mmhg 4. Maximum Tmp-500 Mm/Hg To 600 Mm/Hg 5. Dialyser Membrane-Polysulfone 6. Sterilization Method-Inline Steam Sterilization , Ventriculo Peritoneal Shunt (Medium Pressure) In Sterile Pack , Knitted Polyester Fabric Patch, Size – 4” X 4”. *Thickness Should Be - 0.61Mm,*This Metarial Patch Graft, Endarterectomy Procedures And Asd / Vsd Repair. , Mouth Mirror Small Head , Hand Scaler Set Of 5 Piece , Tweezer Dental (Sizes No. 2) , Pediatric Extraction Lower Incisors & Canine Forcep , Plaster Spatula , Root Canal Explorer Stainless Steel (Cow Horn Design) , Spirit Lamp , Upper Canine Extraction Forcep English Pattern , Upper Incisor Extraction Forcep English Pattern , Upper Molar Extraction Forcep English Pattern , Warwick James Elevators , Surgical Elevators- Cryer’S Pattern , Mouth Mirror With Handle , Renal Stent -4,5,6 & 7Mm.• Stent Base Should Be Cobalt Chromium.• Should Be Rapid Exchange Delivery System (0.014” / 0.36Mm)• Should Be Shaft Size 80 & 120 Cm. , Silver Ion Impregnated Or Hydrophilic And Benzalkonium Chloride Impregnated Triple Lumen Central Venous Catheter : Triple Lumen Pur Catheter, Polymerized With Biguanide Materials Having Antimicrobial Efficacy, Nitinol Guidewire, Valve Needle & Safesite Connector For Needle Free Injection. , Microscope, Binocular, Complete With 2 Eye Pieces And 3 Or 4 (Scanner) Objectives Including Oil Immersion Is: 4381 Along With Is:15269, Is: 8725 And Is: 15268 , Disposable Suction Pod Stabilisation System For Cabg, The Pod Should Rotate 3600 , Basic Set – Procedure Pack Contains Essential Items Needed For A Number Of Common Procedures Including Lumber Puncture, Spinal Anaesthesia, Epidural Anaethesia, Liver Biopsy, Paediatric Surgery, Oncology Etc. (Also Offers Custom Made Service) I. Tray Ii. Syringe Luerslip Iii. Aperture Drape Iv. Galipot V. Prep Forceps Vi. 4 Ball Swab (Small) Vii. 2 Ball Swab (Large) Viii. 1 Filter Needles 5 Um Ix. 3 Hypodermic Needles 18G, 21G & 25G X. 1 Outer Wrap 75 X 70 Cm Xi. Absorbent Towel 33 X 38 Cm , Disposable Fluid Warmer Tubing, * Blood And Iv Fluid Warmer Set With Injection Port. , Ear Speculas Specification : A. Troeltschs Ear Specula, Adult Size, Set Of 3. B. Troeltschs Ear Specula, Infant Size, Set Of 3. , Mono Leaflet Mechanical Prosthetic Mitral / Aortic Valve With Elevated Pivot Guards • Mono Leaflet Rotatable Or Tilting Disc Rotatable • Swing Ring Hence-25 Alloy • Disc Made Of Uhmpe • Swing Ring Made Of Polyester , Pin Index Valve For O2 And N2o For Anaesthetic Apparatus , Positive Airway Pressure System : 1. 22Mm Od Patient End To Accommodate Mounthpiece. 2. Scalloped Ambient Air Inlet With Gaps To Resist Occlusion. 3. Pressure Port With White Sealing Cap, To Allow Connection To A Gauge For Easy Monitoring. 4. Gas Inlet Port To Allow Connection To O2 Source With A Flow Meter. 5. Can Be Used In Conjunction With Aerosol Medication (E.G Nebulizer) Via 22Mm Connection. 6. Available With A Disposable Manometer. 7. Transparent Design For Visual Monitoring Of Contaminants. , Ultrasound Therapy Unit (Two Heads) Technical Specification : Frequency Of 1 & 3 Mhz Intensity Of 0-3 W/Cm2 With Display Of Output Parameters Along With Timer And Two Water Proof Treatment Heads, One Large To 5 Cm Second Small Up To 1.0 Cm System Configuration Accessories Spares And Consumables : - All Standard Accessories Desired For Proper Functioning Of The Machine Jelly As Per Requirement. , Cannula, Femoral Venous Cannula : Kink Resistance Thin Wall, Radio Opaque Bodies With Multiple Side Holes. Depth Markings Permit Precise Positioning Of The Cannula With A Tapered Tip Dilator Which Facilitates Insertion Over 0.038 In. ( 0.1 Cm ) Guide Wire. Size : Assorted, 21 In. (53.3 Cm) Overall Length 25.5 In. (64.8 Cm) Overall Length. , Corrugated Rubber Sheath Drain , Disposable Ventilator Heated Wire Circuit With Water Chamber. Should Be Tidel Volume Range From 200 Ml To 1500 Ml. Should Be Minimal Deade Space 55 Ml. Medical Grade Pe. Connector 15/22 Mm M/F For Y Piece, Connector 15/22 Mm M/F For Ett & Mask. Standard Length. 6Ft. Or Expandable Length. , Oximetry Cable For Cco Monitor (Reusable) , Supraglottic Airway Device 2Nd Generation Specification : 1. Cuff-Should Be Made From Soft Gel Like Material ( Medical Grade Thermoplastic Elastomer) That Should Create A Non-Inflatable, Anatomical Seal Of The Pharyngeal, Laryngeal And Perilaryngeal Structures. 2. 15 Mm Connector. 3. Position Guide 4. Gastric Channel / Drainage Port. 5. Bite Block 6. Buccal Cavity Stabilizer 7. Epiglottis Blocker 8. Display Of Size – For Quick, Easy Reference And Weight Guidance. 9. Can Be Used As A Conduit For Intubation. 10. Size 1,1.5,2,2.5,3,4,5. , Platinum Chromium Coronary Stent System , Important Note: 1. All Prospective Bidders Are Requested To Quote The Rate In Boq As Per Accounting Unit (Au) Repeat As Per Accounting Unit (Au) & Item Specifications As Mentioned In The Table-1. Wrong Quoting Of The Rate In Boq Will Be Dealt With As Per Penal Provisions Of The T&C Of The Tender. 2. Quality Of The Product Supplied, May Be Ascertained By Testing / Physical Examination By The Experts At Any Stage Of The Tender Period. 3. The Equipment Should Be Us Fda/ Ce/ Bis/ Cdsco Approved (Us Fda/ Ce Requirements Will Be Applicable Only When The Indian Standards Like Bis/ Cdsco Is Not Available). 4. The Prospective Bidders Of The Said Tender Are Requested To Make A Declaration In Affidavit Under Annexure Vi(B)In Case Of Sole Manufacturer/Importer (I.E. Proprietary In Nature). 5. If The Item(S) Under Sole Manufacturer / Importer Is (Are) Proprietary In Nature, Quarterly Intimation Is Solicited From The Approved Bidders Positively Regarding The Status Of Their Item(S) Proprietary In Nature, Otherwise Their Item(S) Will Be Blocked In The Smis. 6. In Case Of Tie Bid, Decision Will Be Taken By The Tia As Per G.O. No. 2320-F(Y), Dated 07.06.2022 Issued From Finance Department Audit Branch (Group T).
Contract Date: May 08, 2026 Contract Value : 14
Government Departments No of Bidders 25
West Bengal View Result →
Contract Date: Jun 04, 2026 Contract Value : 2.94 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
14.
Railways #10755501 AOC
Tender For Procurement (Complete Design, Supply ,Installation & Commissioning On Turnkey Basis) Of Pit Less Electronic In Motion Railway Weighbridges (Eimwb) -07 Setprocurement (Complete Design, Supply ,Installation & Commissioning On Turnkey Basis) Of Pit Less Electronic In Motion Railway Weighbridges (Eimwb) -07 Set,Cost Of The Basic Machine , Installation Commissioning And Erection Charges [ Warranty Period: 24 Months After The Date Of Delivery ] ] , Cost Of Comprehensive Type Camc For Ten Years Post Warranty(I.E. Total Sum Of Schedule A & B) [ Warranty Period: 2 Years, Amc Period: 10 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse(C&W)Bndm, Ser Odisha 3.00 Set 3 6525Ns02 Concomitant Non Stock --- Yes Tpi Agency Inr (G01) Accessories (Y) Cost Of Concomitant Accesorries As Per Tender Specification [ Warranty Perio D: 24 Months After The Date Of Delivery ] ] Consignee Sse(C&W)Bndm, Ser Odisha 3.00 Set Inspection Stage Inspection Not Required Details 4 6525Ns03 Essential Non Stock --- Yes Tpi Agency Inr (G01) Spares (Y) Cost Of Any Other Accessory Which In The Opinion Of The Supplier Is Essentially Required For Making The Machine Fully Functional. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse(C&W)Bndm, Ser Odisha 3.00 Set Inspection Stage Inspection Not Required Details Page 1 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 5 6525Ns04 Essential Non Stock --- Yes Consignee Inr (G01) Services (Y) Cost Of Charges Viz Foundation Room Installation & Commissioning Etc. ] At (Location) Sse(C&W)Bndm, Ser Odisha 3.00 Set 6 6525Ns05 Essential Non Stock --- Yes Consignee Inr (G01) Services (Y) Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse(C&W)Bndm, Ser Odisha 3.00 Set Group G02-Dps 1 6525Ns08 Basic Non Stock --- Yes Tpi Agency Inr (G02) Machine (Y) Cost Of The Basic Machine , Installation Commissioning And Erection Charges ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Product Inspection:Stage 1: Raw Material Inspection (100% Of Po Qty ), Stage 2: In Details Process Inspeciton (100% Of Po Qty ) 2 6525Ns12 Amc (Y) Non Stock --- Yes Consignee Inr (G02) Cost Of Comprehensive Type Camc For Ten Years Post Warranty(I.E. Total Sum Of Schedule A & B) [ Warranty Period: 2 Years, Amc Period: 10 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 3 6525Ns07 Concomitant Non Stock --- Yes Tpi Agency Inr (G02) Accessories (Y) Cost Of Concomitant Accesorries As Per Tender Specification [ Warranty Perio D: 24 Months After The Date Of Delivery ] ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Stage Inspection Not Required Details 4 6525Ns09 Essential Non Stock --- Yes Tpi Agency Inr (G02) Spares (Y) Cost Of Any Other Accessory Which In The Opinion Of The Supplier Is Essentially Required For Making The Machine Fully Functional. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Stage Inspection Not Required Details 5 6525Ns10 Essential Non Stock --- Yes Consignee Inr (G02) Services (Y) Cost Of Charges Viz Foundation Room Installation & Commissioning Etc. ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 6 6525Ns11 Essential Non Stock --- Yes Consignee Inr (G02) Services (Y) Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply Page 2 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 For All Items Completion : Within 300 Days 1) Delivery Schedule As Per Clause 9 Annexure 1 Attached 2) Delivery Location - As Per Clause 8 Of Annexure 1 Attached. Payment Terms S.No Description Payment Terms 1 Payment Terms - As Per Clause 12 Of Annexure 1 Attached. Wbg- To Be Submitted As Per Clause 10 Of Annexure 1 Attached. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier/ Contractor. Option Clause S.No Description 1 Plus 30% Option Clause Applicable As Per Clause 24.0 Of Instructions To Tenderers And General Conditions Of Tender For Supply Contract Of South Eastern Railway. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 As Per Rdso Letter No : Mw/Cs/Pewb Normal Applicable To Yes Yes Allowed Dated 11.11.25 Or Latest. Vendor Should All Bidders (Mandatory) Be Approved By Rdso For Manufacturing And Supply Of Pit Less Electronic In Motion Weighbridge(15Kmph). The ϬRm Should Upload The Vendor Approval Copy And Valid Quality Audit Certiï¬Cates Along With Its OffErs, Else The OffEr Submitted Shall Be Summarily Rejected. 2 Preference To Make In India Policy: Normal Applicable To No No Not Allowed Procurement Of The Item Is Restricted To All Bidders Class I Local Suppliers Only And The Vendors Who Do Not Qualify To Be Class I Local Suppliers Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class I Local Supplier For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. Requirement Of A Vendor To Be A Class I Local Supplier For This Item, Shall Be A Mandatory Condition In Addition To Other Qualifying/ Eligibility Criteria/Conditions. Page 3 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 3 Authorised Dealers / Agents Of The Normal Applicable To Yes Yes Allowed Approved Vendors / Oem Must Submit All Bidders (Mandatory) Tender Speciï¬C Authorization Letter From Rdso Approved Manufacturers Of The Item , Failing Which Their OffEr Will Be Summarily Rejected 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Attached The Price Break Up Of Normal Applicable To No No Not Allowed Concomitants Accessories, Optional All Bidders Accessories, Consumables And Essential Spares In Pdf ϬLe Through Attach Document Template Or Otherwise? 2 Have You Quoted Price Of Basic Normal Applicable To No No Not Allowed Machine, Concomitant Accessories, All Bidders Essential Spares, Consumables, Essential Services, Amc And Other Items As Per The Requirement. It Is Mandatory To Submit Offers Against All These Items Otherwise The Bid Shall Not Be Considered In Ranking 3 Have You Quoted For Optional Normal Applicable To No No Not Allowed Accessories,Spares,Amc Etc, If All Bidders Applicable And As Per The Requirement Mentioned In Annexure 1 ? 4 Have You Quoted Warranty Obligations Normal Applicable To No No Not Allowed As Per Clause 16 Of Annexure 1 ? All Bidders 5 Have You Quoted Delivery Period Normal Applicable To No No Not Allowed Correctly And Precisely As Per Sr No 7 All Bidders Of Section Iv Of Annexure 1 Attached? 6 Have You Quoted For Any Other Items Normal Applicable To No No Not Allowed Considered Essential By You For The All Bidders Operation Of The Machine To Meet The Purpose And Capability Specified In Technical Speciï¬Cation.[Under Essential Spares] 7 Have You Submitted Other Supporting Normal Applicable To No No Not Allowed Documents To Establish Your Eligibility ? All Bidders 8 Commercial Details And Performance Normal Applicable To No No Not Allowed Appraisal Form (Annexure E Of Section Vi All Bidders Of Annexure 1 9 Details Related To Compliance Of Normal Applicable To No No Not Allowed Reference Clause Mentioned In Special All Bidders Conditions Of Tender. 10 Have You Attached The Past Normal Applicable To No No Not Allowed Performance Credentials With Your All Bidders Offer? Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 4 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 1 Bidder Are Reminded To Carefully Go Normal Applicable To Yes Yes Allowed Through Irs Conditions Of Contract All Bidders (Optional) (Included And Uploaded Along With The Bid Document) Particularly Those Pertaining To Code Of Integrity,Misdemeanor And Penal Measures. If Two Or More Bidders Are Found To Be Sister Concerns Or Aï¬Ƒliates (Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control, Etc.) The OffErs Of All Such Sister Concerns Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Condition. 2 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Tender Document Consists Of Normal Applicable To No No Not Allowed Annexure 1, Gcc ,Nit And Conditions All Bidders Mentioned In This Document. Tenderers To Ensure Compliance Of Conditions Mentioned In These Documents. Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 1. Inspection By Tpi(Third Party Normal Applicable To No No Not Allowed Inspection). All Bidders 2. There Will Be 02 Stages Of Inspection (Excluding ϬNal Lot Inspection) As Per Speciï¬Cation And Approved Qap As Follows: First Stage - Raw Material Inspection. Second Stage - In Process Inspection. Final Product Inspection At Firms Premises. 2 Firm To Mention Hsn Code & Gstin No. Normal Applicable To Yes Yes Allowed Of The Tendered Item All Bidders (Optional) 3 Emd And Sd Clause Will Be Normal Applicable To Yes Yes Not Allowed Applicable As Per Clause No.5.0 All Bidders And 6.0 Of Gcc Attached Page 5 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 4 Sharing Of Land Border With India Normal Applicable To Yes Yes Allowed Clause: Bidders Are Requested To Go All Bidders (Optional) Through Clause No. 32.0 (32.1 To 32.6) Of Ser Instruction To Tenderers And General Conditions. Bidders Should Conï¬Rm Following Certiï¬Cate For Compliance. (A) I Have Read The Clause Sr. No. 32 Of Instructions To Tenderers And General Conditions Of Tenders For Supply Contract Attached With The Tender Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India Or Bidder Who Has A Speciï¬Ed Transfer Of Technology (T.O.T) Arrangement With An Entity From A Country Which Shares A Land Border With India And On Sub- Contracting To Contractors From Such Countries. (B) I Certify That This Bidder Is Neither From Such A Country Nor Have A Speciï¬Ed Transfer Of Technology (T.O.T) Arrangement With Such An Entity From A Country Which Shares A Land Border With India And Will Not Sub-Contract Any Work To A Contractor From Such Countries Unless Such Contractor Is Registered With The Competent Authority. I Also Certify That This Bidder Will Not OffEr Any Products/Services Of Entity From Such Countries Unless Such Entity Is Registered With The Competent Authority. (C) I Hereby Certify That This Bidder Fulï¬Ls All Requirements In This Regard And Is Eligible To Be Considered. (D) I Hereby Acknowledge That In The Event Of Acceptance Of My Bid On Above Certiï¬Cate And If The Certiï¬Cate Is Found To Be False At Any Stage, The False Certiï¬Cate Would Be A Ground For Immediate Termination Of Contract And Further Legal Action In Accordance With The Law. (Bidders Conï¬Rming This Certiï¬Cate For Compliance Shall Select Yes In The Complied Column. However, In Case You Do Not Conï¬Rm Above Certiï¬Cate For Compliance, Select No In Complied Column. In Such Cases You Are Required To Submit The Certiï¬Cate For Compliance As Per Annexure-8 Instructions To Tenderers And General Conditions Of Tenders For Supply Contract Along-With Their Bid/Offer.) 5 I) There Will Be A Pre-Bid Meeting For Normal Applicable To No No Not Allowed This Tender As Per Speciï¬Ed Date And All Bidders Time. Ii)Venue Of Pre Bid Meeting : Meeting Room Of Pr. Chief Materials Manager (Pcmm) Oï¬Ƒce , 5Th Floor Nab, 11 Garden Reach Road, Kolkata 700043 . 6 Warranty Period: 24 Months After Normal Applicable To No No Not Allowed Date Of Commissioning. All Bidders 7 Any Responsibility Of Cofmow Normal Applicable To No No Not Allowed Mentioned In The Annexure 1, Shall Be All Bidders Of South Eastern Railways. 8 Split Clause Will Be Applicable As Para Normal Applicable To No No Not Allowed 25.0 Of Ser Instruction To Tenderers & All Bidders General Conditions Of Tender Enclosed. The Purchaser Intends To Split The Order Quantity Between Two Or More Firms. Special Conditions Page 6 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges 2 In Case Of Any Mismatch In Conditions Normal Applicable To No No Not Allowed Mentioned In Speciï¬Cation Attached As All Bidders Annexure 1 And In General Conditions Of Contract Attached With Tender, Conditions Mentioned In Annexure 1 Will Supercede The Conditions Mentioned In General Conditions Of Contract. 3 The ϬRm Shall Arrange Calibration, Normal Applicable To No No Not Allowed Testing, Stamping, And Certiï¬Cation Of All Bidders The Weighbridge At Commissioning, During Warranty, And Camc As Per Terms. Any Failures Or Annual Calibration Expenses, Including Statutory Stamping Charges By The State, Shall Be Borne By The Firm 4 If Railway Adopts Pre-Cast Foundation Normal Applicable To No No Not Allowed Technology Under The Weigh-Rail, The All Bidders Firm Shall Execute It Free Of Cost As Per Ser Drawing No. 622/2018 In The Tender Document 5 For Laying Pre-Cast Slabs, If Required, The Normal Applicable To No No Not Allowed Firm Shall Arrange For Road-Mobile Crane All Bidders 6 Railways Will Arrange For Power Supply Normal Applicable To No No Not Allowed To The Control Room Of The Eimwb All Bidders 7 The Railway Will Provide Psc Sleepers Normal Applicable To No No Not Allowed And Will Assist With The Cutting Of Rails All Bidders And The ϬXing Of Weigh-Rails As And When Required. 8 The Railway Will Provide The Necessary Normal Applicable To No No Not Allowed Traffic Block As Per The Firms Request All Bidders 9 The Machine Will Be Under Normal Applicable To No No Not Allowed Comprehensive Preventive Maintenance All Bidders During Warranty Period Of Two (02) Years And Amc For Ten (10) Years 10 Damage Due To Lightning Or Surge, Normal Applicable To No No Not Allowed Covered Under Amc, Will Be Repaired All Bidders Without Extra Cost To Railway. 11 The Eimwb Manufacturers Shall Be Normal Applicable To No No Not Allowed Required To Maintain Spare Part Hubs At All Bidders Strategic Locations ( Spare To Be Kept Within 100 Km Radius Of Installed Eimwb Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Annexure 1 All Bidders (Mandatory) Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical Offer Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 2 Technical Specification As Per Normal Applicable To No No Not Allowed Annexure 1 All Bidders Page 7 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 Undertakings S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 I/We Agree To Supply The Tendered Normal Applicable To No No Not Allowed Stores At The Rates Quoted By Me/Us In All Bidders Accordance With The Conditions Mentioned In Annexure 1, Gcc , Nit And Conditions Mentioned In This Document. 2 I/We Also Conï¬Rm That Rates And Other Normal Applicable To No No Not Allowed Financial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Applicable For Acceptance. Such Terms Quoted Anywhere Else Shall Not Be Considered For Inter-Se Evaluation. 3 Undertaking For Gst. Normal Applicable To No No Not Allowed We Hereby Declare That In Quoting The All Bidders Basic Price, We Have Taken Into Account The Full EffEct Of Input Tax Credit Available Under Gst. We, Further Agree To Pass On Any ϬNancial Gain/Beneï¬T As May Become Available In Future In Respect Of All The Input Tax Credit On The Date Of Supply By Way Of Reduction In Price And Advise The Purchaser Accordingly. We Also Undertake That We Are Aware Of The Provisions Of Section 171 Of The Cgst Act And Consequences Thereof If We Fail To Comply With The Same. We Shall ϬLe Their Gstr-1 And Gstr-3B For Transaction With Railways In Due Time Preferably Every Month So That Itc Benefit Can Be Availed By Railway 6. Bidders Shall Confirm And Certify On The Behalf Of The Tenderer Including Its Constituents As Under: S.No. Description 1 I/We The Tenderer (S) Am/Are Signing This Document After Carefully Reading The Contents. 2 I/We The Tenderer(S) Also Accept All The Conditions Of The Tender And Have Signed All The Pages In Confirmation Thereof. I/We Hereby Declare That I/We Have Downloaded The Tender Documents From Indian Railway Website Www.Ireps.Gov.In . I/We Have Verified The Content Of The Document From The Website And There Is No Addition, No Deletion Or No Alteration To 3 The Content Of The Tender Document. In Case Of Any Discrepancy Noticed At Any Stage I.E. Evaluation Of Tenders, Execution Of Contract Or Payment, The Master Copy Available With The Railway Administration Shall Be Final And Binding Upon Me/Us. I/We Declare And Certify That I/We Have Not Made Any Misleading Or False Representation In The Forms, Statements And 4 Attachments In Proof Of The Qualification Requirements. I/We Also Understand That My/Our Offer Will Be Evaluated Based On The Documents/Credentials Submitted Along With The 5 Offer And Same Shall Be Binding Upon Me/Us. I/We Declare That The Information And Documents Submitted Along With The Tender By Me/Us Are Correct And I/We Are Fully 6 Responsible For The Correctness Of The Information And Documents, Submitted By Us. I/We Certify That I/We The Tenderer(S) Is/Are Not Blacklisted Or Debarred By Railways Or Any Other Ministry / Department Of 7 Govt. Of India From Participation In Tender On The Date Of Submission Of Bids, Either In Individual Capacity Or As A Huf/ Member Of The Partnership Firm/Llp/Jv/Society/Trust. I/We Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be Forged/False At Any Time During Process For Evaluation Of Tenders, It Shall Lead To Forfeiture Of The Emd And May Also Lead To Any Other Action Provided In 8 The Contract Including Banning Of Business For A Period Of Upto Two Year. Further, I/We And All My/Our Constituents Understand That My/Our Offer Shall Be Summarily Rejected. I/We Also Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be False/Forged At Any Time After 9 The Award Of The Contract, It Will Lead To Termination Of The Contract, Along With Forfeiture Of Security Deposit And May Also Lead To Any Other Action Provided In The Contract Including Banning Of Business For A Period Of Upto Two Year. I/We Have Read The Clause Regarding Restriction On Procurement From A Bidder Of A Country Which Shares A Land Border With India And Certify That I Am/We Are Not From Such A Country Or, If From Such A Country, Have Been Registered With The 10 Competent Authority. I/We Hereby Certify That I/We Fulfil All The Requirements In This Regard And Am/Are Eligible To Be Considered (Evidence Of Valid Registration By The Competent Authority Is Enclosed) 7. Documents Attached With Tender S.No. Document Name Document Description Page 8 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 1 5637381.Pdf Foundation Drawing 2 5639851.Pdf Annexure 1 3 5637388.Pdf Irs Conditions 4 5637386.Pdf General Conditons Of Contract 7. Responsiveness S.No. Description Code Of Integrity Declaration: I/We Have Carefully Gone Through The Irs Conditions Of Contract(Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director /Promoter/Owner/Holding Company/Management Control Etc.) Have Participated In This Tender Which Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The OffErs Of All Such Related Concerns Including Ours Are Liable To Be Rejected As Per 1 Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General,With Speciï¬C Reference To ConflIct Of Interest [Para 2502(E)], Anti-Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected At Any Stage. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Et ( Shahid Malik ) Page 9 Of 9 Run Date/Time: 24/12/2025 16:34:04 , Cost Of Concomitant Accesorries As Per Tender Specification [ Warranty Perio D: 24 Months After The Date Of Delivery ] ] , Cost Of Any Other Accessory Which In The Opinion Of The Supplier Is Essentially Required For Making The Machine Fully Functional. [ Warranty Period: 24 Months After The Date Of Delivery ] ] , Cost Of Charges Viz Foundation Room Installation & Commissioning Etc. ] At (Location) Sse(C&W)Bndm, Ser Odisha 3.00 Set 6 6525Ns05 Essential Non Stock --- Yes Consignee Inr (G01) Services (Y) Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse(C&W)Bndm, Ser Odisha 3.00 Set Group G02-Dps 1 6525Ns08 Basic Non Stock --- Yes Tpi Agency Inr (G02) Machine (Y) Cost Of The Basic Machine , Installation Commissioning And Erection Charges ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Product Inspection:Stage 1: Raw Material Inspection (100% Of Po Qty ), Stage 2: In Details Process Inspeciton (100% Of Po Qty ) 2 6525Ns12 Amc (Y) Non Stock --- Yes Consignee Inr (G02) Cost Of Comprehensive Type Camc For Ten Years Post Warranty(I.E. Total Sum Of Schedule A & B) [ Warranty Period: 2 Years, Amc Period: 10 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 3 6525Ns07 Concomitant Non Stock --- Yes Tpi Agency Inr (G02) Accessories (Y) Cost Of Concomitant Accesorries As Per Tender Specification [ Warranty Perio D: 24 Months After The Date Of Delivery ] ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Stage Inspection Not Required Details 4 6525Ns09 Essential Non Stock --- Yes Tpi Agency Inr (G02) Spares (Y) Cost Of Any Other Accessory Which In The Opinion Of The Supplier Is Essentially Required For Making The Machine Fully Functional. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Stage Inspection Not Required Details 5 6525Ns10 Essential Non Stock --- Yes Consignee Inr (G02) Services (Y) Cost Of Charges Viz Foundation Room Installation & Commissioning Etc. ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 6 6525Ns11 Essential Non Stock --- Yes Consignee Inr (G02) Services (Y) Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply Page 2 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 For All Items Completion : Within 300 Days 1) Delivery Schedule As Per Clause 9 Annexure 1 Attached 2) Delivery Location - As Per Clause 8 Of Annexure 1 Attached. Payment Terms S.No Description Payment Terms 1 Payment Terms - As Per Clause 12 Of Annexure 1 Attached. Wbg- To Be Submitted As Per Clause 10 Of Annexure 1 Attached. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier/ Contractor. Option Clause S.No Description 1 Plus 30% Option Clause Applicable As Per Clause 24.0 Of Instructions To Tenderers And General Conditions Of Tender For Supply Contract Of South Eastern Railway. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 As Per Rdso Letter No : Mw/Cs/Pewb Normal Applicable To Yes Yes Allowed Dated 11.11.25 Or Latest. Vendor Should All Bidders (Mandatory) Be Approved By Rdso For Manufacturing And Supply Of Pit Less Electronic In Motion Weighbridge(15Kmph). The ϬRm Should Upload The Vendor Approval Copy And Valid Quality Audit Certiï¬Cates Along With Its OffErs, Else The OffEr Submitted Shall Be Summarily Rejected. 2 Preference To Make In India Policy: Normal Applicable To No No Not Allowed Procurement Of The Item Is Restricted To All Bidders Class I Local Suppliers Only And The Vendors Who Do Not Qualify To Be Class I Local Suppliers Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class I Local Supplier For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. Requirement Of A Vendor To Be A Class I Local Supplier For This Item, Shall Be A Mandatory Condition In Addition To Other Qualifying/ Eligibility Criteria/Conditions. Page 3 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 3 Authorised Dealers / Agents Of The Normal Applicable To Yes Yes Allowed Approved Vendors / Oem Must Submit All Bidders (Mandatory) Tender Speciï¬C Authorization Letter From Rdso Approved Manufacturers Of The Item , Failing Which Their OffEr Will Be Summarily Rejected 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Attached The Price Break Up Of Normal Applicable To No No Not Allowed Concomitants Accessories, Optional All Bidders Accessories, Consumables And Essential Spares In Pdf ϬLe Through Attach Document Template Or Otherwise? 2 Have You Quoted Price Of Basic Normal Applicable To No No Not Allowed Machine, Concomitant Accessories, All Bidders Essential Spares, Consumables, Essential Services, Amc And Other Items As Per The Requirement. It Is Mandatory To Submit Offers Against All These Items Otherwise The Bid Shall Not Be Considered In Ranking 3 Have You Quoted For Optional Normal Applicable To No No Not Allowed Accessories,Spares,Amc Etc, If All Bidders Applicable And As Per The Requirement Mentioned In Annexure 1 ? 4 Have You Quoted Warranty Obligations Normal Applicable To No No Not Allowed As Per Clause 16 Of Annexure 1 ? All Bidders 5 Have You Quoted Delivery Period Normal Applicable To No No Not Allowed Correctly And Precisely As Per Sr No 7 All Bidders Of Section Iv Of Annexure 1 Attached? 6 Have You Quoted For Any Other Items Normal Applicable To No No Not Allowed Considered Essential By You For The All Bidders Operation Of The Machine To Meet The Purpose And Capability Specified In Technical Speciï¬Cation.[Under Essential Spares] 7 Have You Submitted Other Supporting Normal Applicable To No No Not Allowed Documents To Establish Your Eligibility ? All Bidders 8 Commercial Details And Performance Normal Applicable To No No Not Allowed Appraisal Form (Annexure E Of Section Vi All Bidders Of Annexure 1 9 Details Related To Compliance Of Normal Applicable To No No Not Allowed Reference Clause Mentioned In Special All Bidders Conditions Of Tender. 10 Have You Attached The Past Normal Applicable To No No Not Allowed Performance Credentials With Your All Bidders Offer? Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 4 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 1 Bidder Are Reminded To Carefully Go Normal Applicable To Yes Yes Allowed Through Irs Conditions Of Contract All Bidders (Optional) (Included And Uploaded Along With The Bid Document) Particularly Those Pertaining To Code Of Integrity,Misdemeanor And Penal Measures. If Two Or More Bidders Are Found To Be Sister Concerns Or Aï¬Ƒliates (Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control, Etc.) The OffErs Of All Such Sister Concerns Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Condition. 2 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Tender Document Consists Of Normal Applicable To No No Not Allowed Annexure 1, Gcc ,Nit And Conditions All Bidders Mentioned In This Document. Tenderers To Ensure Compliance Of Conditions Mentioned In These Documents. Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 1. Inspection By Tpi(Third Party Normal Applicable To No No Not Allowed Inspection). All Bidders 2. There Will Be 02 Stages Of Inspection (Excluding ϬNal Lot Inspection) As Per Speciï¬Cation And Approved Qap As Follows: First Stage - Raw Material Inspection. Second Stage - In Process Inspection. Final Product Inspection At Firms Premises. 2 Firm To Mention Hsn Code & Gstin No. Normal Applicable To Yes Yes Allowed Of The Tendered Item All Bidders (Optional) 3 Emd And Sd Clause Will Be Normal Applicable To Yes Yes Not Allowed Applicable As Per Clause No.5.0 All Bidders And 6.0 Of Gcc Attached Page 5 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 4 Sharing Of Land Border With India Normal Applicable To Yes Yes Allowed Clause: Bidders Are Requested To Go All Bidders (Optional) Through Clause No. 32.0 (32.1 To 32.6) Of Ser Instruction To Tenderers And General Conditions. Bidders Should Conï¬Rm Following Certiï¬Cate For Compliance. (A) I Have Read The Clause Sr. No. 32 Of Instructions To Tenderers And General Conditions Of Tenders For Supply Contract Attached With The Tender Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India Or Bidder Who Has A Speciï¬Ed Transfer Of Technology (T.O.T) Arrangement With An Entity From A Country Which Shares A Land Border With India And On Sub- Contracting To Contractors From Such Countries. (B) I Certify That This Bidder Is Neither From Such A Country Nor Have A Speciï¬Ed Transfer Of Technology (T.O.T) Arrangement With Such An Entity From A Country Which Shares A Land Border With India And Will Not Sub-Contract Any Work To A Contractor From Such Countries Unless Such Contractor Is Registered With The Competent Authority. I Also Certify That This Bidder Will Not OffEr Any Products/Services Of Entity From Such Countries Unless Such Entity Is Registered With The Competent Authority. (C) I Hereby Certify That This Bidder Fulï¬Ls All Requirements In This Regard And Is Eligible To Be Considered. (D) I Hereby Acknowledge That In The Event Of Acceptance Of My Bid On Above Certiï¬Cate And If The Certiï¬Cate Is Found To Be False At Any Stage, The False Certiï¬Cate Would Be A Ground For Immediate Termination Of Contract And Further Legal Action In Accordance With The Law. (Bidders Conï¬Rming This Certiï¬Cate For Compliance Shall Select Yes In The Complied Column. However, In Case You Do Not Conï¬Rm Above Certiï¬Cate For Compliance, Select No In Complied Column. In Such Cases You Are Required To Submit The Certiï¬Cate For Compliance As Per Annexure-8 Instructions To Tenderers And General Conditions Of Tenders For Supply Contract Along-With Their Bid/Offer.) 5 I) There Will Be A Pre-Bid Meeting For Normal Applicable To No No Not Allowed This Tender As Per Speciï¬Ed Date And All Bidders Time. Ii)Venue Of Pre Bid Meeting : Meeting Room Of Pr. Chief Materials Manager (Pcmm) Oï¬Ƒce , 5Th Floor Nab, 11 Garden Reach Road, Kolkata 700043 . 6 Warranty Period: 24 Months After Normal Applicable To No No Not Allowed Date Of Commissioning. All Bidders 7 Any Responsibility Of Cofmow Normal Applicable To No No Not Allowed Mentioned In The Annexure 1, Shall Be All Bidders Of South Eastern Railways. 8 Split Clause Will Be Applicable As Para Normal Applicable To No No Not Allowed 25.0 Of Ser Instruction To Tenderers & All Bidders General Conditions Of Tender Enclosed. The Purchaser Intends To Split The Order Quantity Between Two Or More Firms. Special Conditions Page 6 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges 2 In Case Of Any Mismatch In Conditions Normal Applicable To No No Not Allowed Mentioned In Speciï¬Cation Attached As All Bidders Annexure 1 And In General Conditions Of Contract Attached With Tender, Conditions Mentioned In Annexure 1 Will Supercede The Conditions Mentioned In General Conditions Of Contract. 3 The ϬRm Shall Arrange Calibration, Normal Applicable To No No Not Allowed Testing, Stamping, And Certiï¬Cation Of All Bidders The Weighbridge At Commissioning, During Warranty, And Camc As Per Terms. Any Failures Or Annual Calibration Expenses, Including Statutory Stamping Charges By The State, Shall Be Borne By The Firm 4 If Railway Adopts Pre-Cast Foundation Normal Applicable To No No Not Allowed Technology Under The Weigh-Rail, The All Bidders Firm Shall Execute It Free Of Cost As Per Ser Drawing No. 622/2018 In The Tender Document 5 For Laying Pre-Cast Slabs, If Required, The Normal Applicable To No No Not Allowed Firm Shall Arrange For Road-Mobile Crane All Bidders 6 Railways Will Arrange For Power Supply Normal Applicable To No No Not Allowed To The Control Room Of The Eimwb All Bidders 7 The Railway Will Provide Psc Sleepers Normal Applicable To No No Not Allowed And Will Assist With The Cutting Of Rails All Bidders And The ϬXing Of Weigh-Rails As And When Required. 8 The Railway Will Provide The Necessary Normal Applicable To No No Not Allowed Traffic Block As Per The Firms Request All Bidders 9 The Machine Will Be Under Normal Applicable To No No Not Allowed Comprehensive Preventive Maintenance All Bidders During Warranty Period Of Two (02) Years And Amc For Ten (10) Years 10 Damage Due To Lightning Or Surge, Normal Applicable To No No Not Allowed Covered Under Amc, Will Be Repaired All Bidders Without Extra Cost To Railway. 11 The Eimwb Manufacturers Shall Be Normal Applicable To No No Not Allowed Required To Maintain Spare Part Hubs At All Bidders Strategic Locations ( Spare To Be Kept Within 100 Km Radius Of Installed Eimwb Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Annexure 1 All Bidders (Mandatory) Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical Offer Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 2 Technical Specification As Per Normal Applicable To No No Not Allowed Annexure 1 All Bidders Page 7 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 Undertakings S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 I/We Agree To Supply The Tendered Normal Applicable To No No Not Allowed Stores At The Rates Quoted By Me/Us In All Bidders Accordance With The Conditions Mentioned In Annexure 1, Gcc , Nit And Conditions Mentioned In This Document. 2 I/We Also Conï¬Rm That Rates And Other Normal Applicable To No No Not Allowed Financial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Applicable For Acceptance. Such Terms Quoted Anywhere Else Shall Not Be Considered For Inter-Se Evaluation. 3 Undertaking For Gst. Normal Applicable To No No Not Allowed We Hereby Declare That In Quoting The All Bidders Basic Price, We Have Taken Into Account The Full EffEct Of Input Tax Credit Available Under Gst. We, Further Agree To Pass On Any ϬNancial Gain/Beneï¬T As May Become Available In Future In Respect Of All The Input Tax Credit On The Date Of Supply By Way Of Reduction In Price And Advise The Purchaser Accordingly. We Also Undertake That We Are Aware Of The Provisions Of Section 171 Of The Cgst Act And Consequences Thereof If We Fail To Comply With The Same. We Shall ϬLe Their Gstr-1 And Gstr-3B For Transaction With Railways In Due Time Preferably Every Month So That Itc Benefit Can Be Availed By Railway 6. Bidders Shall Confirm And Certify On The Behalf Of The Tenderer Including Its Constituents As Under: S.No. Description 1 I/We The Tenderer (S) Am/Are Signing This Document After Carefully Reading The Contents. 2 I/We The Tenderer(S) Also Accept All The Conditions Of The Tender And Have Signed All The Pages In Confirmation Thereof. I/We Hereby Declare That I/We Have Downloaded The Tender Documents From Indian Railway Website Www.Ireps.Gov.In . I/We Have Verified The Content Of The Document From The Website And There Is No Addition, No Deletion Or No Alteration To 3 The Content Of The Tender Document. In Case Of Any Discrepancy Noticed At Any Stage I.E. Evaluation Of Tenders, Execution Of Contract Or Payment, The Master Copy Available With The Railway Administration Shall Be Final And Binding Upon Me/Us. I/We Declare And Certify That I/We Have Not Made Any Misleading Or False Representation In The Forms, Statements And 4 Attachments In Proof Of The Qualification Requirements. I/We Also Understand That My/Our Offer Will Be Evaluated Based On The Documents/Credentials Submitted Along With The 5 Offer And Same Shall Be Binding Upon Me/Us. I/We Declare That The Information And Documents Submitted Along With The Tender By Me/Us Are Correct And I/We Are Fully 6 Responsible For The Correctness Of The Information And Documents, Submitted By Us. I/We Certify That I/We The Tenderer(S) Is/Are Not Blacklisted Or Debarred By Railways Or Any Other Ministry / Department Of 7 Govt. Of India From Participation In Tender On The Date Of Submission Of Bids, Either In Individual Capacity Or As A Huf/ Member Of The Partnership Firm/Llp/Jv/Society/Trust. I/We Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be Forged/False At Any Time During Process For Evaluation Of Tenders, It Shall Lead To Forfeiture Of The Emd And May Also Lead To Any Other Action Provided In 8 The Contract Including Banning Of Business For A Period Of Upto Two Year. Further, I/We And All My/Our Constituents Understand That My/Our Offer Shall Be Summarily Rejected. I/We Also Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be False/Forged At Any Time After 9 The Award Of The Contract, It Will Lead To Termination Of The Contract, Along With Forfeiture Of Security Deposit And May Also Lead To Any Other Action Provided In The Contract Including Banning Of Business For A Period Of Upto Two Year. I/We Have Read The Clause Regarding Restriction On Procurement From A Bidder Of A Country Which Shares A Land Border With India And Certify That I Am/We Are Not From Such A Country Or, If From Such A Country, Have Been Registered With The 10 Competent Authority. I/We Hereby Certify That I/We Fulfil All The Requirements In This Regard And Am/Are Eligible To Be Considered (Evidence Of Valid Registration By The Competent Authority Is Enclosed) 7. Documents Attached With Tender S.No. Document Name Document Description Page 8 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 1 5637381.Pdf Foundation Drawing 2 5639851.Pdf Annexure 1 3 5637388.Pdf Irs Conditions 4 5637386.Pdf General Conditons Of Contract 7. Responsiveness S.No. Description Code Of Integrity Declaration: I/We Have Carefully Gone Through The Irs Conditions Of Contract(Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director /Promoter/Owner/Holding Company/Management Control Etc.) Have Participated In This Tender Which Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The OffErs Of All Such Related Concerns Including Ours Are Liable To Be Rejected As Per 1 Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General,With Speciï¬C Reference To ConflIct Of Interest [Para 2502(E)], Anti-Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected At Any Stage. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Et ( Shahid Malik ) Page 9 Of 9 Run Date/Time: 24/12/2025 16:34:04 , Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse(C&W)Bndm, Ser Odisha 3.00 Set Group G02-Dps 1 6525Ns08 Basic Non Stock --- Yes Tpi Agency Inr (G02) Machine (Y) Cost Of The Basic Machine , Installation Commissioning And Erection Charges ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Product Inspection:Stage 1: Raw Material Inspection (100% Of Po Qty ), Stage 2: In Details Process Inspeciton (100% Of Po Qty ) 2 6525Ns12 Amc (Y) Non Stock --- Yes Consignee Inr (G02) Cost Of Comprehensive Type Camc For Ten Years Post Warranty(I.E. Total Sum Of Schedule A & B) [ Warranty Period: 2 Years, Amc Period: 10 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 3 6525Ns07 Concomitant Non Stock --- Yes Tpi Agency Inr (G02) Accessories (Y) Cost Of Concomitant Accesorries As Per Tender Specification [ Warranty Perio D: 24 Months After The Date Of Delivery ] ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Stage Inspection Not Required Details 4 6525Ns09 Essential Non Stock --- Yes Tpi Agency Inr (G02) Spares (Y) Cost Of Any Other Accessory Which In The Opinion Of The Supplier Is Essentially Required For Making The Machine Fully Functional. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Stage Inspection Not Required Details 5 6525Ns10 Essential Non Stock --- Yes Consignee Inr (G02) Services (Y) Cost Of Charges Viz Foundation Room Installation & Commissioning Etc. ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 6 6525Ns11 Essential Non Stock --- Yes Consignee Inr (G02) Services (Y) Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply Page 2 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 For All Items Completion : Within 300 Days 1) Delivery Schedule As Per Clause 9 Annexure 1 Attached 2) Delivery Location - As Per Clause 8 Of Annexure 1 Attached. Payment Terms S.No Description Payment Terms 1 Payment Terms - As Per Clause 12 Of Annexure 1 Attached. Wbg- To Be Submitted As Per Clause 10 Of Annexure 1 Attached. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier/ Contractor. Option Clause S.No Description 1 Plus 30% Option Clause Applicable As Per Clause 24.0 Of Instructions To Tenderers And General Conditions Of Tender For Supply Contract Of South Eastern Railway. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 As Per Rdso Letter No : Mw/Cs/Pewb Normal Applicable To Yes Yes Allowed Dated 11.11.25 Or Latest. Vendor Should All Bidders (Mandatory) Be Approved By Rdso For Manufacturing And Supply Of Pit Less Electronic In Motion Weighbridge(15Kmph). The ϬRm Should Upload The Vendor Approval Copy And Valid Quality Audit Certiï¬Cates Along With Its OffErs, Else The OffEr Submitted Shall Be Summarily Rejected. 2 Preference To Make In India Policy: Normal Applicable To No No Not Allowed Procurement Of The Item Is Restricted To All Bidders Class I Local Suppliers Only And The Vendors Who Do Not Qualify To Be Class I Local Suppliers Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class I Local Supplier For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. Requirement Of A Vendor To Be A Class I Local Supplier For This Item, Shall Be A Mandatory Condition In Addition To Other Qualifying/ Eligibility Criteria/Conditions. Page 3 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 3 Authorised Dealers / Agents Of The Normal Applicable To Yes Yes Allowed Approved Vendors / Oem Must Submit All Bidders (Mandatory) Tender Speciï¬C Authorization Letter From Rdso Approved Manufacturers Of The Item , Failing Which Their OffEr Will Be Summarily Rejected 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Attached The Price Break Up Of Normal Applicable To No No Not Allowed Concomitants Accessories, Optional All Bidders Accessories, Consumables And Essential Spares In Pdf ϬLe Through Attach Document Template Or Otherwise? 2 Have You Quoted Price Of Basic Normal Applicable To No No Not Allowed Machine, Concomitant Accessories, All Bidders Essential Spares, Consumables, Essential Services, Amc And Other Items As Per The Requirement. It Is Mandatory To Submit Offers Against All These Items Otherwise The Bid Shall Not Be Considered In Ranking 3 Have You Quoted For Optional Normal Applicable To No No Not Allowed Accessories,Spares,Amc Etc, If All Bidders Applicable And As Per The Requirement Mentioned In Annexure 1 ? 4 Have You Quoted Warranty Obligations Normal Applicable To No No Not Allowed As Per Clause 16 Of Annexure 1 ? All Bidders 5 Have You Quoted Delivery Period Normal Applicable To No No Not Allowed Correctly And Precisely As Per Sr No 7 All Bidders Of Section Iv Of Annexure 1 Attached? 6 Have You Quoted For Any Other Items Normal Applicable To No No Not Allowed Considered Essential By You For The All Bidders Operation Of The Machine To Meet The Purpose And Capability Specified In Technical Speciï¬Cation.[Under Essential Spares] 7 Have You Submitted Other Supporting Normal Applicable To No No Not Allowed Documents To Establish Your Eligibility ? All Bidders 8 Commercial Details And Performance Normal Applicable To No No Not Allowed Appraisal Form (Annexure E Of Section Vi All Bidders Of Annexure 1 9 Details Related To Compliance Of Normal Applicable To No No Not Allowed Reference Clause Mentioned In Special All Bidders Conditions Of Tender. 10 Have You Attached The Past Normal Applicable To No No Not Allowed Performance Credentials With Your All Bidders Offer? Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 4 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 1 Bidder Are Reminded To Carefully Go Normal Applicable To Yes Yes Allowed Through Irs Conditions Of Contract All Bidders (Optional) (Included And Uploaded Along With The Bid Document) Particularly Those Pertaining To Code Of Integrity,Misdemeanor And Penal Measures. If Two Or More Bidders Are Found To Be Sister Concerns Or Aï¬Ƒliates (Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control, Etc.) The OffErs Of All Such Sister Concerns Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Condition. 2 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Tender Document Consists Of Normal Applicable To No No Not Allowed Annexure 1, Gcc ,Nit And Conditions All Bidders Mentioned In This Document. Tenderers To Ensure Compliance Of Conditions Mentioned In These Documents. Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 1. Inspection By Tpi(Third Party Normal Applicable To No No Not Allowed Inspection). All Bidders 2. There Will Be 02 Stages Of Inspection (Excluding ϬNal Lot Inspection) As Per Speciï¬Cation And Approved Qap As Follows: First Stage - Raw Material Inspection. Second Stage - In Process Inspection. Final Product Inspection At Firms Premises. 2 Firm To Mention Hsn Code & Gstin No. Normal Applicable To Yes Yes Allowed Of The Tendered Item All Bidders (Optional) 3 Emd And Sd Clause Will Be Normal Applicable To Yes Yes Not Allowed Applicable As Per Clause No.5.0 All Bidders And 6.0 Of Gcc Attached Page 5 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 4 Sharing Of Land Border With India Normal Applicable To Yes Yes Allowed Clause: Bidders Are Requested To Go All Bidders (Optional) Through Clause No. 32.0 (32.1 To 32.6) Of Ser Instruction To Tenderers And General Conditions. Bidders Should Conï¬Rm Following Certiï¬Cate For Compliance. (A) I Have Read The Clause Sr. No. 32 Of Instructions To Tenderers And General Conditions Of Tenders For Supply Contract Attached With The Tender Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India Or Bidder Who Has A Speciï¬Ed Transfer Of Technology (T.O.T) Arrangement With An Entity From A Country Which Shares A Land Border With India And On Sub- Contracting To Contractors From Such Countries. (B) I Certify That This Bidder Is Neither From Such A Country Nor Have A Speciï¬Ed Transfer Of Technology (T.O.T) Arrangement With Such An Entity From A Country Which Shares A Land Border With India And Will Not Sub-Contract Any Work To A Contractor From Such Countries Unless Such Contractor Is Registered With The Competent Authority. I Also Certify That This Bidder Will Not OffEr Any Products/Services Of Entity From Such Countries Unless Such Entity Is Registered With The Competent Authority. (C) I Hereby Certify That This Bidder Fulï¬Ls All Requirements In This Regard And Is Eligible To Be Considered. (D) I Hereby Acknowledge That In The Event Of Acceptance Of My Bid On Above Certiï¬Cate And If The Certiï¬Cate Is Found To Be False At Any Stage, The False Certiï¬Cate Would Be A Ground For Immediate Termination Of Contract And Further Legal Action In Accordance With The Law. (Bidders Conï¬Rming This Certiï¬Cate For Compliance Shall Select Yes In The Complied Column. However, In Case You Do Not Conï¬Rm Above Certiï¬Cate For Compliance, Select No In Complied Column. In Such Cases You Are Required To Submit The Certiï¬Cate For Compliance As Per Annexure-8 Instructions To Tenderers And General Conditions Of Tenders For Supply Contract Along-With Their Bid/Offer.) 5 I) There Will Be A Pre-Bid Meeting For Normal Applicable To No No Not Allowed This Tender As Per Speciï¬Ed Date And All Bidders Time. Ii)Venue Of Pre Bid Meeting : Meeting Room Of Pr. Chief Materials Manager (Pcmm) Oï¬Ƒce , 5Th Floor Nab, 11 Garden Reach Road, Kolkata 700043 . 6 Warranty Period: 24 Months After Normal Applicable To No No Not Allowed Date Of Commissioning. All Bidders 7 Any Responsibility Of Cofmow Normal Applicable To No No Not Allowed Mentioned In The Annexure 1, Shall Be All Bidders Of South Eastern Railways. 8 Split Clause Will Be Applicable As Para Normal Applicable To No No Not Allowed 25.0 Of Ser Instruction To Tenderers & All Bidders General Conditions Of Tender Enclosed. The Purchaser Intends To Split The Order Quantity Between Two Or More Firms. Special Conditions Page 6 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges 2 In Case Of Any Mismatch In Conditions Normal Applicable To No No Not Allowed Mentioned In Speciï¬Cation Attached As All Bidders Annexure 1 And In General Conditions Of Contract Attached With Tender, Conditions Mentioned In Annexure 1 Will Supercede The Conditions Mentioned In General Conditions Of Contract. 3 The ϬRm Shall Arrange Calibration, Normal Applicable To No No Not Allowed Testing, Stamping, And Certiï¬Cation Of All Bidders The Weighbridge At Commissioning, During Warranty, And Camc As Per Terms. Any Failures Or Annual Calibration Expenses, Including Statutory Stamping Charges By The State, Shall Be Borne By The Firm 4 If Railway Adopts Pre-Cast Foundation Normal Applicable To No No Not Allowed Technology Under The Weigh-Rail, The All Bidders Firm Shall Execute It Free Of Cost As Per Ser Drawing No. 622/2018 In The Tender Document 5 For Laying Pre-Cast Slabs, If Required, The Normal Applicable To No No Not Allowed Firm Shall Arrange For Road-Mobile Crane All Bidders 6 Railways Will Arrange For Power Supply Normal Applicable To No No Not Allowed To The Control Room Of The Eimwb All Bidders 7 The Railway Will Provide Psc Sleepers Normal Applicable To No No Not Allowed And Will Assist With The Cutting Of Rails All Bidders And The ϬXing Of Weigh-Rails As And When Required. 8 The Railway Will Provide The Necessary Normal Applicable To No No Not Allowed Traffic Block As Per The Firms Request All Bidders 9 The Machine Will Be Under Normal Applicable To No No Not Allowed Comprehensive Preventive Maintenance All Bidders During Warranty Period Of Two (02) Years And Amc For Ten (10) Years 10 Damage Due To Lightning Or Surge, Normal Applicable To No No Not Allowed Covered Under Amc, Will Be Repaired All Bidders Without Extra Cost To Railway. 11 The Eimwb Manufacturers Shall Be Normal Applicable To No No Not Allowed Required To Maintain Spare Part Hubs At All Bidders Strategic Locations ( Spare To Be Kept Within 100 Km Radius Of Installed Eimwb Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Annexure 1 All Bidders (Mandatory) Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical Offer Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 2 Technical Specification As Per Normal Applicable To No No Not Allowed Annexure 1 All Bidders Page 7 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 Undertakings S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 I/We Agree To Supply The Tendered Normal Applicable To No No Not Allowed Stores At The Rates Quoted By Me/Us In All Bidders Accordance With The Conditions Mentioned In Annexure 1, Gcc , Nit And Conditions Mentioned In This Document. 2 I/We Also Conï¬Rm That Rates And Other Normal Applicable To No No Not Allowed Financial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Applicable For Acceptance. Such Terms Quoted Anywhere Else Shall Not Be Considered For Inter-Se Evaluation. 3 Undertaking For Gst. Normal Applicable To No No Not Allowed We Hereby Declare That In Quoting The All Bidders Basic Price, We Have Taken Into Account The Full EffEct Of Input Tax Credit Available Under Gst. We, Further Agree To Pass On Any ϬNancial Gain/Beneï¬T As May Become Available In Future In Respect Of All The Input Tax Credit On The Date Of Supply By Way Of Reduction In Price And Advise The Purchaser Accordingly. We Also Undertake That We Are Aware Of The Provisions Of Section 171 Of The Cgst Act And Consequences Thereof If We Fail To Comply With The Same. We Shall ϬLe Their Gstr-1 And Gstr-3B For Transaction With Railways In Due Time Preferably Every Month So That Itc Benefit Can Be Availed By Railway 6. Bidders Shall Confirm And Certify On The Behalf Of The Tenderer Including Its Constituents As Under: S.No. Description 1 I/We The Tenderer (S) Am/Are Signing This Document After Carefully Reading The Contents. 2 I/We The Tenderer(S) Also Accept All The Conditions Of The Tender And Have Signed All The Pages In Confirmation Thereof. I/We Hereby Declare That I/We Have Downloaded The Tender Documents From Indian Railway Website Www.Ireps.Gov.In . I/We Have Verified The Content Of The Document From The Website And There Is No Addition, No Deletion Or No Alteration To 3 The Content Of The Tender Document. In Case Of Any Discrepancy Noticed At Any Stage I.E. Evaluation Of Tenders, Execution Of Contract Or Payment, The Master Copy Available With The Railway Administration Shall Be Final And Binding Upon Me/Us. I/We Declare And Certify That I/We Have Not Made Any Misleading Or False Representation In The Forms, Statements And 4 Attachments In Proof Of The Qualification Requirements. I/We Also Understand That My/Our Offer Will Be Evaluated Based On The Documents/Credentials Submitted Along With The 5 Offer And Same Shall Be Binding Upon Me/Us. I/We Declare That The Information And Documents Submitted Along With The Tender By Me/Us Are Correct And I/We Are Fully 6 Responsible For The Correctness Of The Information And Documents, Submitted By Us. I/We Certify That I/We The Tenderer(S) Is/Are Not Blacklisted Or Debarred By Railways Or Any Other Ministry / Department Of 7 Govt. Of India From Participation In Tender On The Date Of Submission Of Bids, Either In Individual Capacity Or As A Huf/ Member Of The Partnership Firm/Llp/Jv/Society/Trust. I/We Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be Forged/False At Any Time During Process For Evaluation Of Tenders, It Shall Lead To Forfeiture Of The Emd And May Also Lead To Any Other Action Provided In 8 The Contract Including Banning Of Business For A Period Of Upto Two Year. Further, I/We And All My/Our Constituents Understand That My/Our Offer Shall Be Summarily Rejected. I/We Also Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be False/Forged At Any Time After 9 The Award Of The Contract, It Will Lead To Termination Of The Contract, Along With Forfeiture Of Security Deposit And May Also Lead To Any Other Action Provided In The Contract Including Banning Of Business For A Period Of Upto Two Year. I/We Have Read The Clause Regarding Restriction On Procurement From A Bidder Of A Country Which Shares A Land Border With India And Certify That I Am/We Are Not From Such A Country Or, If From Such A Country, Have Been Registered With The 10 Competent Authority. I/We Hereby Certify That I/We Fulfil All The Requirements In This Regard And Am/Are Eligible To Be Considered (Evidence Of Valid Registration By The Competent Authority Is Enclosed) 7. Documents Attached With Tender S.No. Document Name Document Description Page 8 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 1 5637381.Pdf Foundation Drawing 2 5639851.Pdf Annexure 1 3 5637388.Pdf Irs Conditions 4 5637386.Pdf General Conditons Of Contract 7. Responsiveness S.No. Description Code Of Integrity Declaration: I/We Have Carefully Gone Through The Irs Conditions Of Contract(Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director /Promoter/Owner/Holding Company/Management Control Etc.) Have Participated In This Tender Which Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The OffErs Of All Such Related Concerns Including Ours Are Liable To Be Rejected As Per 1 Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General,With Speciï¬C Reference To ConflIct Of Interest [Para 2502(E)], Anti-Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected At Any Stage. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Et ( Shahid Malik ) Page 9 Of 9 Run Date/Time: 24/12/2025 16:34:04 , Cost Of The Basic Machine , Installation Commissioning And Erection Charges ] , Cost Of Comprehensive Type Camc For Ten Years Post Warranty(I.E. Total Sum Of Schedule A & B) [ Warranty Period: 2 Years, Amc Period: 10 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 3 6525Ns07 Concomitant Non Stock --- Yes Tpi Agency Inr (G02) Accessories (Y) Cost Of Concomitant Accesorries As Per Tender Specification [ Warranty Perio D: 24 Months After The Date Of Delivery ] ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Stage Inspection Not Required Details 4 6525Ns09 Essential Non Stock --- Yes Tpi Agency Inr (G02) Spares (Y) Cost Of Any Other Accessory Which In The Opinion Of The Supplier Is Essentially Required For Making The Machine Fully Functional. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse/C&W/Dps, Ser Jharkhand 4.00 Set Inspection Stage Inspection Not Required Details 5 6525Ns10 Essential Non Stock --- Yes Consignee Inr (G02) Services (Y) Cost Of Charges Viz Foundation Room Installation & Commissioning Etc. ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 6 6525Ns11 Essential Non Stock --- Yes Consignee Inr (G02) Services (Y) Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply Page 2 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 For All Items Completion : Within 300 Days 1) Delivery Schedule As Per Clause 9 Annexure 1 Attached 2) Delivery Location - As Per Clause 8 Of Annexure 1 Attached. Payment Terms S.No Description Payment Terms 1 Payment Terms - As Per Clause 12 Of Annexure 1 Attached. Wbg- To Be Submitted As Per Clause 10 Of Annexure 1 Attached. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier/ Contractor. Option Clause S.No Description 1 Plus 30% Option Clause Applicable As Per Clause 24.0 Of Instructions To Tenderers And General Conditions Of Tender For Supply Contract Of South Eastern Railway. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 As Per Rdso Letter No : Mw/Cs/Pewb Normal Applicable To Yes Yes Allowed Dated 11.11.25 Or Latest. Vendor Should All Bidders (Mandatory) Be Approved By Rdso For Manufacturing And Supply Of Pit Less Electronic In Motion Weighbridge(15Kmph). The ϬRm Should Upload The Vendor Approval Copy And Valid Quality Audit Certiï¬Cates Along With Its OffErs, Else The OffEr Submitted Shall Be Summarily Rejected. 2 Preference To Make In India Policy: Normal Applicable To No No Not Allowed Procurement Of The Item Is Restricted To All Bidders Class I Local Suppliers Only And The Vendors Who Do Not Qualify To Be Class I Local Suppliers Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class I Local Supplier For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. Requirement Of A Vendor To Be A Class I Local Supplier For This Item, Shall Be A Mandatory Condition In Addition To Other Qualifying/ Eligibility Criteria/Conditions. Page 3 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 3 Authorised Dealers / Agents Of The Normal Applicable To Yes Yes Allowed Approved Vendors / Oem Must Submit All Bidders (Mandatory) Tender Speciï¬C Authorization Letter From Rdso Approved Manufacturers Of The Item , Failing Which Their OffEr Will Be Summarily Rejected 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Attached The Price Break Up Of Normal Applicable To No No Not Allowed Concomitants Accessories, Optional All Bidders Accessories, Consumables And Essential Spares In Pdf ϬLe Through Attach Document Template Or Otherwise? 2 Have You Quoted Price Of Basic Normal Applicable To No No Not Allowed Machine, Concomitant Accessories, All Bidders Essential Spares, Consumables, Essential Services, Amc And Other Items As Per The Requirement. It Is Mandatory To Submit Offers Against All These Items Otherwise The Bid Shall Not Be Considered In Ranking 3 Have You Quoted For Optional Normal Applicable To No No Not Allowed Accessories,Spares,Amc Etc, If All Bidders Applicable And As Per The Requirement Mentioned In Annexure 1 ? 4 Have You Quoted Warranty Obligations Normal Applicable To No No Not Allowed As Per Clause 16 Of Annexure 1 ? All Bidders 5 Have You Quoted Delivery Period Normal Applicable To No No Not Allowed Correctly And Precisely As Per Sr No 7 All Bidders Of Section Iv Of Annexure 1 Attached? 6 Have You Quoted For Any Other Items Normal Applicable To No No Not Allowed Considered Essential By You For The All Bidders Operation Of The Machine To Meet The Purpose And Capability Specified In Technical Speciï¬Cation.[Under Essential Spares] 7 Have You Submitted Other Supporting Normal Applicable To No No Not Allowed Documents To Establish Your Eligibility ? All Bidders 8 Commercial Details And Performance Normal Applicable To No No Not Allowed Appraisal Form (Annexure E Of Section Vi All Bidders Of Annexure 1 9 Details Related To Compliance Of Normal Applicable To No No Not Allowed Reference Clause Mentioned In Special All Bidders Conditions Of Tender. 10 Have You Attached The Past Normal Applicable To No No Not Allowed Performance Credentials With Your All Bidders Offer? Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 4 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 1 Bidder Are Reminded To Carefully Go Normal Applicable To Yes Yes Allowed Through Irs Conditions Of Contract All Bidders (Optional) (Included And Uploaded Along With The Bid Document) Particularly Those Pertaining To Code Of Integrity,Misdemeanor And Penal Measures. If Two Or More Bidders Are Found To Be Sister Concerns Or Aï¬Ƒliates (Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control, Etc.) The OffErs Of All Such Sister Concerns Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Condition. 2 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Tender Document Consists Of Normal Applicable To No No Not Allowed Annexure 1, Gcc ,Nit And Conditions All Bidders Mentioned In This Document. Tenderers To Ensure Compliance Of Conditions Mentioned In These Documents. Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 1. Inspection By Tpi(Third Party Normal Applicable To No No Not Allowed Inspection). All Bidders 2. There Will Be 02 Stages Of Inspection (Excluding ϬNal Lot Inspection) As Per Speciï¬Cation And Approved Qap As Follows: First Stage - Raw Material Inspection. Second Stage - In Process Inspection. Final Product Inspection At Firms Premises. 2 Firm To Mention Hsn Code & Gstin No. Normal Applicable To Yes Yes Allowed Of The Tendered Item All Bidders (Optional) 3 Emd And Sd Clause Will Be Normal Applicable To Yes Yes Not Allowed Applicable As Per Clause No.5.0 All Bidders And 6.0 Of Gcc Attached Page 5 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 4 Sharing Of Land Border With India Normal Applicable To Yes Yes Allowed Clause: Bidders Are Requested To Go All Bidders (Optional) Through Clause No. 32.0 (32.1 To 32.6) Of Ser Instruction To Tenderers And General Conditions. Bidders Should Conï¬Rm Following Certiï¬Cate For Compliance. (A) I Have Read The Clause Sr. No. 32 Of Instructions To Tenderers And General Conditions Of Tenders For Supply Contract Attached With The Tender Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India Or Bidder Who Has A Speciï¬Ed Transfer Of Technology (T.O.T) Arrangement With An Entity From A Country Which Shares A Land Border With India And On Sub- Contracting To Contractors From Such Countries. (B) I Certify That This Bidder Is Neither From Such A Country Nor Have A Speciï¬Ed Transfer Of Technology (T.O.T) Arrangement With Such An Entity From A Country Which Shares A Land Border With India And Will Not Sub-Contract Any Work To A Contractor From Such Countries Unless Such Contractor Is Registered With The Competent Authority. I Also Certify That This Bidder Will Not OffEr Any Products/Services Of Entity From Such Countries Unless Such Entity Is Registered With The Competent Authority. (C) I Hereby Certify That This Bidder Fulï¬Ls All Requirements In This Regard And Is Eligible To Be Considered. (D) I Hereby Acknowledge That In The Event Of Acceptance Of My Bid On Above Certiï¬Cate And If The Certiï¬Cate Is Found To Be False At Any Stage, The False Certiï¬Cate Would Be A Ground For Immediate Termination Of Contract And Further Legal Action In Accordance With The Law. (Bidders Conï¬Rming This Certiï¬Cate For Compliance Shall Select Yes In The Complied Column. However, In Case You Do Not Conï¬Rm Above Certiï¬Cate For Compliance, Select No In Complied Column. In Such Cases You Are Required To Submit The Certiï¬Cate For Compliance As Per Annexure-8 Instructions To Tenderers And General Conditions Of Tenders For Supply Contract Along-With Their Bid/Offer.) 5 I) There Will Be A Pre-Bid Meeting For Normal Applicable To No No Not Allowed This Tender As Per Speciï¬Ed Date And All Bidders Time. Ii)Venue Of Pre Bid Meeting : Meeting Room Of Pr. Chief Materials Manager (Pcmm) Oï¬Ƒce , 5Th Floor Nab, 11 Garden Reach Road, Kolkata 700043 . 6 Warranty Period: 24 Months After Normal Applicable To No No Not Allowed Date Of Commissioning. All Bidders 7 Any Responsibility Of Cofmow Normal Applicable To No No Not Allowed Mentioned In The Annexure 1, Shall Be All Bidders Of South Eastern Railways. 8 Split Clause Will Be Applicable As Para Normal Applicable To No No Not Allowed 25.0 Of Ser Instruction To Tenderers & All Bidders General Conditions Of Tender Enclosed. The Purchaser Intends To Split The Order Quantity Between Two Or More Firms. Special Conditions Page 6 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges 2 In Case Of Any Mismatch In Conditions Normal Applicable To No No Not Allowed Mentioned In Speciï¬Cation Attached As All Bidders Annexure 1 And In General Conditions Of Contract Attached With Tender, Conditions Mentioned In Annexure 1 Will Supercede The Conditions Mentioned In General Conditions Of Contract. 3 The ϬRm Shall Arrange Calibration, Normal Applicable To No No Not Allowed Testing, Stamping, And Certiï¬Cation Of All Bidders The Weighbridge At Commissioning, During Warranty, And Camc As Per Terms. Any Failures Or Annual Calibration Expenses, Including Statutory Stamping Charges By The State, Shall Be Borne By The Firm 4 If Railway Adopts Pre-Cast Foundation Normal Applicable To No No Not Allowed Technology Under The Weigh-Rail, The All Bidders Firm Shall Execute It Free Of Cost As Per Ser Drawing No. 622/2018 In The Tender Document 5 For Laying Pre-Cast Slabs, If Required, The Normal Applicable To No No Not Allowed Firm Shall Arrange For Road-Mobile Crane All Bidders 6 Railways Will Arrange For Power Supply Normal Applicable To No No Not Allowed To The Control Room Of The Eimwb All Bidders 7 The Railway Will Provide Psc Sleepers Normal Applicable To No No Not Allowed And Will Assist With The Cutting Of Rails All Bidders And The ϬXing Of Weigh-Rails As And When Required. 8 The Railway Will Provide The Necessary Normal Applicable To No No Not Allowed Traffic Block As Per The Firms Request All Bidders 9 The Machine Will Be Under Normal Applicable To No No Not Allowed Comprehensive Preventive Maintenance All Bidders During Warranty Period Of Two (02) Years And Amc For Ten (10) Years 10 Damage Due To Lightning Or Surge, Normal Applicable To No No Not Allowed Covered Under Amc, Will Be Repaired All Bidders Without Extra Cost To Railway. 11 The Eimwb Manufacturers Shall Be Normal Applicable To No No Not Allowed Required To Maintain Spare Part Hubs At All Bidders Strategic Locations ( Spare To Be Kept Within 100 Km Radius Of Installed Eimwb Technical-Compliances S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Annexure 1 All Bidders (Mandatory) Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical Offer Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 2 Technical Specification As Per Normal Applicable To No No Not Allowed Annexure 1 All Bidders Page 7 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 Undertakings S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 I/We Agree To Supply The Tendered Normal Applicable To No No Not Allowed Stores At The Rates Quoted By Me/Us In All Bidders Accordance With The Conditions Mentioned In Annexure 1, Gcc , Nit And Conditions Mentioned In This Document. 2 I/We Also Conï¬Rm That Rates And Other Normal Applicable To No No Not Allowed Financial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Applicable For Acceptance. Such Terms Quoted Anywhere Else Shall Not Be Considered For Inter-Se Evaluation. 3 Undertaking For Gst. Normal Applicable To No No Not Allowed We Hereby Declare That In Quoting The All Bidders Basic Price, We Have Taken Into Account The Full EffEct Of Input Tax Credit Available Under Gst. We, Further Agree To Pass On Any ϬNancial Gain/Beneï¬T As May Become Available In Future In Respect Of All The Input Tax Credit On The Date Of Supply By Way Of Reduction In Price And Advise The Purchaser Accordingly. We Also Undertake That We Are Aware Of The Provisions Of Section 171 Of The Cgst Act And Consequences Thereof If We Fail To Comply With The Same. We Shall ϬLe Their Gstr-1 And Gstr-3B For Transaction With Railways In Due Time Preferably Every Month So That Itc Benefit Can Be Availed By Railway 6. Bidders Shall Confirm And Certify On The Behalf Of The Tenderer Including Its Constituents As Under: S.No. Description 1 I/We The Tenderer (S) Am/Are Signing This Document After Carefully Reading The Contents. 2 I/We The Tenderer(S) Also Accept All The Conditions Of The Tender And Have Signed All The Pages In Confirmation Thereof. I/We Hereby Declare That I/We Have Downloaded The Tender Documents From Indian Railway Website Www.Ireps.Gov.In . I/We Have Verified The Content Of The Document From The Website And There Is No Addition, No Deletion Or No Alteration To 3 The Content Of The Tender Document. In Case Of Any Discrepancy Noticed At Any Stage I.E. Evaluation Of Tenders, Execution Of Contract Or Payment, The Master Copy Available With The Railway Administration Shall Be Final And Binding Upon Me/Us. I/We Declare And Certify That I/We Have Not Made Any Misleading Or False Representation In The Forms, Statements And 4 Attachments In Proof Of The Qualification Requirements. I/We Also Understand That My/Our Offer Will Be Evaluated Based On The Documents/Credentials Submitted Along With The 5 Offer And Same Shall Be Binding Upon Me/Us. I/We Declare That The Information And Documents Submitted Along With The Tender By Me/Us Are Correct And I/We Are Fully 6 Responsible For The Correctness Of The Information And Documents, Submitted By Us. I/We Certify That I/We The Tenderer(S) Is/Are Not Blacklisted Or Debarred By Railways Or Any Other Ministry / Department Of 7 Govt. Of India From Participation In Tender On The Date Of Submission Of Bids, Either In Individual Capacity Or As A Huf/ Member Of The Partnership Firm/Llp/Jv/Society/Trust. I/We Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be Forged/False At Any Time During Process For Evaluation Of Tenders, It Shall Lead To Forfeiture Of The Emd And May Also Lead To Any Other Action Provided In 8 The Contract Including Banning Of Business For A Period Of Upto Two Year. Further, I/We And All My/Our Constituents Understand That My/Our Offer Shall Be Summarily Rejected. I/We Also Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be False/Forged At Any Time After 9 The Award Of The Contract, It Will Lead To Termination Of The Contract, Along With Forfeiture Of Security Deposit And May Also Lead To Any Other Action Provided In The Contract Including Banning Of Business For A Period Of Upto Two Year. I/We Have Read The Clause Regarding Restriction On Procurement From A Bidder Of A Country Which Shares A Land Border With India And Certify That I Am/We Are Not From Such A Country Or, If From Such A Country, Have Been Registered With The 10 Competent Authority. I/We Hereby Certify That I/We Fulfil All The Requirements In This Regard And Am/Are Eligible To Be Considered (Evidence Of Valid Registration By The Competent Authority Is Enclosed) 7. Documents Attached With Tender S.No. Document Name Document Description Page 8 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document Tender No 65255048 Closing Date/Time 23/01/2026 14:00 1 5637381.Pdf Foundation Drawing 2 5639851.Pdf Annexure 1 3 5637388.Pdf Irs Conditions 4 5637386.Pdf General Conditons Of Contract 7. Responsiveness S.No. Description Code Of Integrity Declaration: I/We Have Carefully Gone Through The Irs Conditions Of Contract(Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director /Promoter/Owner/Holding Company/Management Control Etc.) Have Participated In This Tender Which Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The OffErs Of All Such Related Concerns Including Ours Are Liable To Be Rejected As Per 1 Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General,With Speciï¬C Reference To ConflIct Of Interest [Para 2502(E)], Anti-Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected At Any Stage. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Et ( Shahid Malik ) Page 9 Of 9 Run Date/Time: 24/12/2025 16:34:04 , Cost Of Concomitant Accesorries As Per Tender Specification [ Warranty Perio D: 24 Months After The Date Of Delivery ] ] , Cost Of Any Other Accessory Which In The Opinion Of The Supplier Is Essentially Required For Making The Machine Fully Functional. [ Warranty Period: 24 Months After The Date Of Delivery ] ] , Cost Of Charges Viz Foundation Room Installation & Commissioning Etc. ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 6 6525Ns11 Essential Non Stock --- Yes Consignee Inr (G02) Services (Y) Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply Page 2 Of 9 Run Date/Time: 24/12/2025 16:34:04Stores-Pcmm/South Eastern Rly Tender Document , Cost Of Preventive Maintenance During 1St & 2Nd Year Of Warranty Period ] At (Location) Sse/C&W/Dps, Ser Jharkhand 4.00 Set 3.
Contract Date: Apr 11, 2026 Contract Value : 1.93 Crore
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
16.
Educational and Research Institute #10618062 Price Bid
Supply Of Surgical Instruments-2 Halogen bulb 15V/150W with reflector 3 Spot light Bulb 12V/100W with reflector 4 Halogen bulb 15W/ 230W with reflector 5 Laryngoscope bulb, 6 Curved Macintosh laryngoscope with 4 blades including extra large blade, 7 Laryngoscope Pediatric, Straight Blade 8 Knife Handle for B.P. Blade No. 3 & 4 9 Humbys Knife for Skin Grafting 10 Proctoscope _Adult 11 Proctoscope _Child 12 LED X-Ray View Box Double film 13 LED X-Ray View Box 4 film 14 Weighing machine Portable 15 Skin Grafting blade 16 Suture Needle No. 9 to 20 Cutting/Round body (Pkt) 17 Autoclave Label (Pkt of 500 lables) 18 Gigli saw wire 19 Electric Nebulizer 20 Formalin Chamber 26 21 Formalin Chamber 21 22 Simcoe cannula No. 22 &23 23 Suction Tip (Neurosurgery) 24 Sphygmomanometer Mercury Type Table Model 25 LED Sphygmomanometer Mercury free (B.P. Instrument) 26 Oxygen Key Steel 27 Chilamchi with stand 28 Suction Machine for use in Operation theatre Trolley Model with safety belt v- Belt Driven 0.5 H.P. Model double Bottle built in Stabilizer . 29 Oxygen Cylinder 2-00 Cubic meter with explosive certificate& Filled with gas 30 Oxygen Cylinder 1.40 Cubic meter with explosive certificate& Filled with gas 31 Oxygen Cylinder (Bulk size D-type High pressure seamless cylinders for Medical oxygen gas, cylinder are ISI Marked confirming to IS: 7285, certified by the Bureau of Indian Standards (BIS) and approved by the chief controller of Explosives (CCOE) Government of India. 46.7 Ltr Water Capacity (220CU.FT.) fitted with bull nose type valve as per IS:3224, and neck cap. color code of the cylinder should as per IS 3933-1966 with updating till date. Certificate from department of experiment of explosion Government of India to be provided for specified cylinder. Working Pressure 150Kg. f/cm2 at 15deg. C, Hydraulic test pressure 250Kg. f/cm2. 32 Dressing Drum: 350x240 mm Seamless for Autoclave Purpose 33 Dressing Drum: 350x275mm Seamless for Autoclave Purpose 34 Electric Instrument Sterilizer Size:-430 x 200 x 150mm 35 Electric Instrument Sterilizer Big Size (70 Ltr or More) 36 Instrument tray (S.S.) size 450x300mm with Cover 37 Regulator Mox 26 B with self-celling valve with three meter high pressure tubing with on side may matching probe & one side pin indies valve for Medical Oxygen 38 Oxygen Regulator Single Stage 39 Regulator MNO 32 with self-celling valve with three meter high pressure tubing with on side may matching probe & one side pin index valve for Nitrous Gas 40 Stand Mounted Infra-Red Lamp 41 Gauze Holding Forceps 42 Cutting Loop-24Ch, Yellow color (double stem) 43 TURP Cutting Loop, 24 fr single Stem (Compatible with Olympus Company) 44 Cold knife (Double Stem)24fr 45 Cooling knife 24Fr. 46 B.P. Blade No 10 to 24 47 Artery forceps-Straight 4 48 Artery forceps-Straight 5 49 Artery forceps-Straight 6 50 Artery forceps-Straight 8 51 Artery forceps-Straight 10 52 Artery forceps-Curved 4 53 Artery forceps-Curved 5 54 Artery forceps-Curved 6 55 Artery forceps-Curved 8 56 Artery forceps-Curved 10 57 Corneal Artery Forceps 58 Hoskins Non Toothed Artery Forceps 59 Jewelers Non Tooth Artery Forceps 60 Adson Artery Forceps 61 Micro Adson Artery Forceps 62 Sponge Holding Forceps(Rappley Sponge) 63 Mosquito Artery Forceps Straight size 4 64 Mosquito Artery Forceps Straight size 5 65 Mosquito Artery Forceps Straight size 6 66 Mosquito Artery Forceps Straight size 8 67 Mosquito Artery Forceps Straight size 10 68 Mosquito Artery Forceps Curved size 4 69 Mosquito Artery Forceps Curved size 5 70 Mosquito Artery Forceps Curved size 6 71 Mosquito Artery Forceps Curved size 8 72 Mosquito Artery Forceps Curved size 10 73 Robert Artery Forceps: Adult/ Child 74 Surgical Scissor: Straight 4 75 Surgical Scissor: Straight 5 76 Surgical Scissor: Straight 6 77 Surgical Scissor: Straight 7 78 Surgical Scissor: Straight 8 79 Surgical Scissor: Straight 10 80 Surgical Scissor: Curved 4 81 Surgical Scissor: Curved 5 82 Surgical Scissor: Curved 6 83 Surgical Scissor: Curved 7 84 Surgical Scissor: Curved 8 85 Surgical Scissor: Curved 10 86 Surgical Scissor: IRIS (CURVED/SHARP) 4 87 Vascular Clamp :5 to 10 Straight 88 Suction Nozzle-Med. Fine 89 Stitch Remover Scissor 90 Allies Forceps 4 91 Allies Forceps 5 92 Allies Forceps 6 93 Allies Forceps 8 94 Allies Forceps 10 95 Tooth forceps-4 96 Tooth forceps-5 97 Tooth forceps-6 98 Tooth forceps-8 99 Tooth forceps-10 100 Non Tooth Dissecting forceps-4 101 Non Tooth Dissecting forceps-5 102 Non Tooth Dissecting forceps-6 103 Non Tooth Dissecting forceps-8 104 Non Tooth Dissecting forceps-10 105 Bab Coke Forcep-5 106 Bab Coke Forcep-6 107 Bab Coke Forcep-8 108 Bab Coke Forcep-10 109 Tooth Dissecting forceps-5 110 Tooth Dissecting forceps-6 111 Tooth Dissecting forceps-8 112 Tooth Dissecting forceps-10 113 Needle Holder-4 114 Needle Holder-5 115 Needle Holder-6 116 Needle Holder-8 117 Needle Holder-10 118 Cheetal forceps 8 119 Cheetal forceps 10 120 Magills forceps (Audit,) 121 Magills forceps (Pediatric) 122 Traction Kit-Plain Above Knee 123 Traction Kit-Plain below Knee 124 Traction Kit-Plain Sponge below Knee 125 K- Wire cutter Small (Each) 126 K- Wire cutter Large (Each) 127 Wire bending Pliers –155 cm. 128 Thomas Splints : all size 129 Battery Operating Drill Machine 12 Volt 130 Needle & Syringe Destroyer cum Cutter Manual 2 ltr or more 131 Nitrous Cylinder 1851 LTr. 132 Co2 Cylinder 9 Kg Cap. Filled with Gas. 133 Fogger Machine Technical Specifications 1. Input Power : 220~240 VAC, 50/60 Hz., 4.5 amps Single Phase 2. Timer Device : Electronic Timer (5~60 Minutes adjustment) 3. Nozzle Assembly: High-shear,non-rotating,non-clogging,Vortex design . 4. Liquid Flow Rate: 0 ~ 300 ml/min. (Depends on viscosity of liquid). 5. Flow Control Valve : Five Turn Valve. Valve Lock Feature. 6. Particle Size: 1 ~ 5 microns (Dry fog) 8 ~10 microns (Ultra fine fog) n15 ~ 35 microns (Heavy fog) 40 + microns (Wet fog) 7.Reach: Upto 10000 cubic fts. otional>2000mtr.sq 8.Tank Capacity: 6.5 Ltrs. (SS tank) 9. MOC : Power head housing & tank - aluminium Tubing - fuel and oil resistant vintyl. Flow Control Valve, Strainer wiremesh & fittings-SS304 Nozzle - Engg.Plastic. 10. Shipping Dimensions: 15 x 15 x 18 inches (39 x 39 x 46 cms.) - L x W x H. 11. Dry Weight 6 kgs. 134 Mc_Coy Laryngoscope Blade No 1,2,3,4,5 135 Mc_Coy Laryngoscope Blade With Standerd Hendle 136 Humidifier bottle of FA Valve 137 BPC Flowmeter with humidifier 138 600 ml vaccum jar 139 1000 ml vaccum jar 140 2000 ml vaccum jar 141 K-Wire Single & Double ended Size 1,1.5 & 2.0 142 ECG Machine single Channel 143 Adult Oxygen Mask with Resrvoir Bag (Hi Mask) 144 Face Shield 145 Shoe Cover 146 Dead Body Cover (For COVID Body) Specification:- n1- Impermeable, 2-Leak proof. 3-Air sealed. 4-Double sealed. 5-Disposable, 6-Opaque. 7-White, 8-U shape with Zip, 9-Size 2.2 X 1.2 Mts, 10. Standerds-(ISO / DIS Certified) 147 Adult Stethoscope 148 Pediatric Stethoscope 149 Kidney Tray 150 Steplar Stich Remover 151 Urethral Dialor Set - Lister Type male 152 Urethral Dialor Set - Hegar Type female 153 Catheter Introducer matellic 154 Cidex Tray S.S., Heavy Guage 0.7mm or more Size 30 x 6 x 5 Inch 155 Floor Suction Machine
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Uttar Pradesh View Result →
20.
Drinking Water Supply and Sanitation #10482650 Price Bid
Tender For Purchase Of Colony Counter For Wazirabad And Tyr Lab -The Colony Counter Shall Be Of Automatic Type The Machine Shall Be Capable Of Reading All Automatically Different Types And Sizes Of Plates With The Same Instrument. The Colony Counter Will Have Following Features Mandatorily; 1. The Colony Counter Will Be Of Utmost Accuracy. There Will Be Uniform Reflection With Spherical Chamber. , 2- With The Help Of The Software, It Must Be Capable Of Detecting Wide Range Of Colony Types., 3 - The Software Will Have User Management And Audit Trail. 4- Software Will Be Capable Of Detecting Colonies Of 0.3 Mm., 5- Analysis Time Will Be Less Than 10 Seconds, 6-Software: The Software Is Designed To Filter And Classify Colonies By Colors And Diameters.It Will Be Able To Count Colonies In Spiral Distribution And Will Also Distinguish Colonies On Challenging Backgrounds. The Software Can Distinguish Overlapped Colonies. Software Will Have Following Features Also;1- Automatic Calibration And Verification., 2- Lims Interface, 3- Statistical Reports And Lab Report Generation With Djb Logo 4- Image And Data Export, 5- Audit Trailtechnical Specifications: The Light Source Shall Be Leds And Oriented To The Internal Wall Of A Moving Spheric Chamber And Comes From Above And / Or Below The Chamber. The Result Is An Unprecedent Uniform And Reflection Free Illumination In The Colony Counter Device.The Moving Sphere Must Automatically Close The Chamber And Prevents The Area From Any External Light.Other Technical Specifications: Computer Interface Usb 3.0 Type-A Socket, Lluminating System Automatic Lifting Sphere, Reflection Lighting Led, Diffused By The Spheretransmitted Lighting Led, Homogeneous Surface, Protection Of The External Light Interference Opaque Sphere, Kind Of Samples 90Mm Dish; 60Mm Dish; Filter Disc; Films, Sensor & Camera Cmos 5Mpixel, Operation Time 2 Seconds ( Minimum ) , Petri Dish Maximum Usable Diameter 90Mm Computer Interface: Usb 3.0 Type-A Socket Mains Ac Adaptor, Output 12V Dc 3.43A, Power Range 90~264 Vac, Frequency Range 47~63Hzmaximum Power 40W, Overvoltage Category Ii, Air Temperature 15–30ºc ( 59–86ºf ) , Relative Humidity 10–75% ( Non-Condensing ) Altitude: Up To 2000 M ( 6500Ft ) , Place Of Operation For Indoor Use Only, Frequency Range 50–60Hz, Pollution Level 2, Dimensions 288×220×371 Mm ( 1.34×8.66×14.6 In ) Weight: 5.5 Kg ( 12.13Lb )
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 18
Uttar Pradesh View Result →
24.
Health and Family Welfare #10306167 Price Bid
tender for Neet Ayush Ug Councilling 2025 - 1-Installation of computer, printer, UPS and furniture on rent basis for the entire period of counselling at counselling centre. (1) Desktop PC (Intel core i5 Desktop 20. Inch TFT, 1TB HDD or 256 GBSSD,8 GB RAM DDR4/DDR3, Window 11 Professnol) -45 Nos (2) 10 KVA Online UPS. -02 Nos (3) Multifunction Printer Laserjet -04 Nos (4) Computer Chair -45 Nos (5) Computer Table(4*3) -45 Nos 2-Work related to installation of internet networking line wiring along with other necessary materials for smooth internet facility in computer lab. 3-All work related to necessary electrical arrangements at counselling computer lab and other counselling rooms. 4-Work related to installation of 2 separate internet lease lines (Airtel / BSNL) of 2 Gbps each for carrying out online counselling work. 5- Arrangement of necessary furniture (velvet chair, fibre chair, cool jug, dustbin, fan etc.) on rent basis for various stages of counselling (first, second, third phase and stray vacancy cycle etc.) - (1) Velvet Chair - 30 Nos (2) Fibre Chair - 1000 Nos (3) Cool Jug - 10 Nos (4) Table/PadlestFan - 10 Nos (5) Dust Bin (Big) - 20 Nos (6) Generator 10KVA - 01 Nos (7) Tent/ Light and other Furniture - As Per Requirement 6- Arrangement of complete videography/photography etc. of various stages of counselling (first, second, third phase and stray vacancy cycle etc.) on rent basis per day - (1) LED TV 55 inch with Stand - 03 Nos (2) 2MP IP Camera setup with NVR -20 Nos (3) HDD For Councilig Recording (1TB) 10 Nos (4) Counselling Videography Work -As Per Requirement (5)Councilling Photography Work -As Per Requirement. 7- Arrangement of necessary office stationery to be purchased for various stages of counselling (1st, 2nd, 3rd stage and stray vacancy cycle etc.)- (1) Photocopier Paper(Century) - 250 Rim (2) Ball Pen -500 Nos (3) File Cover - 1000 Nos (4) Steplor No-45 -20 Nos (5) Tag - 200 Lachi (6) Register 2 Q - 40 Nos (7) Glue Stick -100 Pcs 8-Arrangement of manpower for execution of work on daily wages for all stages of counselling- 1- Technical Manpower-05 2- Labourer -05 3- Sweeper -02 9- Arrangement of breakfast and lunch packets for approximately 100 persons per day for all stages of counselling. 10- Arrangement of tea 3 times per day for 200 persons, 1000 packets of mineral water and 15000 packets of disposable glasses for all the stages of counselling. 11- Bulk SMS pack (maximum amount Rs. 1,00,000/-) to be taken from BSNL/private sector telecom company for providing State Data Centre/Gmail facility for e-mail to send necessary messages to the candidates in the counselling process. 12- Updated software for counselling process to be done under the supervision of third party security audit and Secured Socket Layer (SSL) NIC Lucknow by any institution authorised/nominated by Government of India. 13- Work related to making of 05 posters/banners size-4×3 required related to counselling work. 14- Purchase of 04 cupboards for safekeeping of records related to AYUSH counseling. 15- Hiring of 02 cars/taxi on monthly rent for 04 months for transportation of members of counseling board etc. during counseling work. 1 UP UG Counselling 2025-26 2 DESKTOP PC(INTEL COREI5,20 INCH TFT,1TB HDD Or 256 GB SSD,8GB RAM, DDR4/DDR ,3WINDOWS 11 PRO 3 10 KVA ONLINE UPS SYSTEM 4 MULTIFUNTION PRINTER LASERJET (PRINT ,COPY,SCAN) 5 COMPUTER TABLE 6 COMPUTER CHAIR 7 COMPLETE INTERNET NETWORKING WORK (TOTAL COST) 8 ELECTRIC WORK COMPLETE (TOTAL COST) 9 INTERNET LEASE LINE DEDECATED (PER MONTH) 10 VELVET CHAIR 11 FIBER CHAIR 12 PADESTAL FAN 13 GENERTOR 10 KVA 14 COOL JUG 15 DUST BIN BIG 16 LED TV SETUP 55INCH 17 2MP IP CAMERA SETUP WITH NVR AND OPPERATOR 18 COUNSELLING VIDEOGRAPHY WORK 19 COUNSELLING PHOTOGRAPHY WORK 20 HARD DISK 4TB EXTERNAL 21 PHOTO COPIER PAPER 75 GSM 22 BALL PEN 23 FILE COVER 24 SETPLER 45NO 25 TAG (BANDAL) 26 REGISTER 2Q 27 GLU STICK 28 MINIRAL WATER -200 ML 29 DISPOSAL GLASS PER PACKET 30 TEA PER CUP 31 BREAK FAST PER PACKET 32 LUNCH PER PACKET 33 BULK SMS PACK (MAXIMUM RS.100000) 34 POSTER AND BANNER (SIZE 4*3) pcs 35 CAR TAXI (SEDON) 36 ALMIRHA STEEL 37 MAN POWER (TECHNICAL-01,LABOUR-01,SWIPER-01) 38 TENT/LIGHT ETC (10 X10 FT, 1 Light ) 39 COUNSELLING WEBSITE SECURITY AUDIT AND ASI WORK WITH COMPLETION (1 Job) 40 DIESEL PER LITER
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
29.
Educational and Research Institute #10088358 Price Bid
Supply Of Books , Library Books , Machine Design, T. V. Sundararajamoorthy & N. Shanmuga ,Anuradha Publications, Kumbakonam. , Revised Edition June-2003 , Industrial Motor Control., Stephen Herman ,Cengage Learning , 6Th Edition , Electrical Technology, Edward Hughes ,Addision– Wesley International Student Edition , Latest Edition , Mysql, Paul Dubois ,Addison Wesley , 4Th Edition , No Sql Distilled, Pramod J. Sadalage Martin Fowler ,Addison Wesley , 1St Edition Or Latest Reprint , American Society Of Metals – Hand Book – Volume 4 ( Forming), American Society Of Metals,American Society Of Metals , Latest Edition , Programmable Controller Theory And Implementation, L.A.Bryan E.A.Bryan ,An Industrial Text Company Publication , Latest Edition , Biomedical Instrumentation, M. Arumugam ,Anuradha Publications, Chennai , Latest Edition , Android Apps For Absolute Beginners, Jackson ,Apress , Latest Edition , Computer Installation And Servicing, D.Balasubramanian ,Arasan Ganesan Institute Of Technology , 1993 , Home Refrigeration And Air Conditioning, Audels, Theo. ,Audel & Co. Publisher, New York. - 1998 , 199 Edn.49 , Remote Sensing And Geographical Information System, M.Anji Reddy ,B.S Publications , Latest Edition , The Complete Pc Upgrade And Maintenance, Mark Minasi ,Bpb Publication , 1997 , Exploring Programmable Logic Controller With Applications, Pradeep Kumar Srivastava ,Bpb Publication , Latest Edition , The Complete Pc Upgrade And Maintenance, Mark Minasi ,Bpb Publication , Latest Edition , Advanced Mobile Repairing, Pandit Sanjib ,Bpb Publication , First Edition 2010 , Modern Vcd Video Cd Player Introduction, Servicing And Troubleshooting, Manohar Lotia & Pradeep Nair ,Bpb Publication , Latest Edition , Explosing Programmable Logic Controllers With Application., Pradeep Kumar Srivastava. ,Bpb Publication , Latest Edition , Let Us C, Yeswanth Kanetkar ,Bpb Publication , 16Th Edition , Programmable Logic Controller, Pradeep Kumar & Srivashtava ,Bpb Publication , Latest Edition , Modern Computer Hardware Course, Manahar Lotai, Pradeep Niar, Payal Lotia ,Bpb Publication , Second Revised Edition 2011 , Inside Autocad, D. Raker And H. Rice,Bpb Publication , Latest Edition , Text Book Of Environmental Science And Technology, M.Anji Reddi ,Bs Publications , Latest Edition , Book 1 - General Aspect Of Energy Management And Energy Audit,,Bureau Of Energy Efficiency, New Delhi , Second- 2005 , Book 3 - Energy Efficiency In Electrical Utilities,,Bureau Of Energy Efficiency, New Delhi , Second- 2005 , National Building Code Of India – 2005,,,Bureau Of Indian Standards, New Delhi , Latest Edition , Total Quality Management, Oakiand.J.S.,Butterworth Heinemann Ltd. Oxford , 1989 , The Art Of Electronics, Paul Horowitz ,Cambridge University , 2Nd Edition Press , Performance And Design Of Ac Machine, M.G.Say ,Cbs Publisher & Distributor , Latest Edition , A Text Book Of Soil Mechanics, Dr S B Sehgal ,Cbs Publisher & Distributors , Latest Edition , Building Repair And Maintenance Management, P.S.Gahlot ,Cbs Publisher & Distributors (P) Ltd , Latest Edition , Learning Material Development Project – Nitttr,,Cd Programme On Gps And Gis. , Latest Edition , Introduction To Programmable Logic Controllers, Gary Dunning ,Cengagelearning India Pvt Ltd , Latest Edition , Building Materials, S.C.Rangwala ,Charotar Publishing House , 1982 , Building Construction, S.C.Rangwala ,Charotar Publishing House , Latest Edition , Mechanics Of Structures (Vol Ii), S.B. Junnarkar ,Charotar Publishing House , 22Nd Edition , Highway Engineering, Rangwala ,Charotar Publishing House , 2010 , Railway Engineering, Rangwala ,Charotar Publishing House , 2010 , Bridge Engineering, Rangwala ,Charotar Publishing House , 2009 , Estimating & Costing, Rangawala ,Charotar Publishing House , Latest Edition , Construction Of Structures And Management Of Works, Rangwala.S.C ,Charotar Publishing House , Latest Edition , Machine Design, Pandya & Shah ,Charotar Publishing House , 1995 , Principle Of Geographical Information Systems For Land Resources Assessment, Burrough P.A. (2000) ,Clarendon Press, Oxford. , Latest Edition , Technician’S Guide To Programmable Logic Controllers, Richard A. Cox ,Delmer , Sixth Edition 2011 , Principles Of The Manufacturing Of Composite Materials , Suong V Hoa, ,Des Tech Publication. Inc , Latest Edition , Strength Of Materials, S.Ramamirtham ,Dhanpat Rai , 2003 , A Course In Electrical And Electronics Measurements And Instrumentation., A.K. Sawhney Puneet Sawhney ,Dhanpat Rai , Latest Edition , Estimating & Costing, L.N.Dutta ,Dhanpat Rai , Latest Edition , Thermal Engineering., B.K. Sarkar. ,Dhanpat Rai , 3Rd Edition , Internal Combustion Engines, M.L.Mathur & R.P.Sharma ,Dhanpat Rai , Latest Edition , Mechanical Draughtsmanship,G.L. Tamta, Dhanpat Rai ,Dhanpat Rai , Latest Edition , Engineering Drawing, D.N. Ghose ,Dhanpat Rai , Latest Edition , A Course In Electrical Power, Soni & Gupta ,Dhanpat Rai , Latest Edition , Hydraulics,Fluid Mechanics And Hydraulics Machines, S. Ramamirtham ,Dhanpat Rai , Latest Edition , Modern Electric Traction, H Partab ,Dhanpat Rai , Latest Edition , Mechanical Measurements, A.K.Sawhney-Dhanpat Rai & Sons ,Dhanpat Rai , Latest Edition , Electronic Measurements And Instrumentation, Sanjay Talbar & Akhilesh Upadhyaya ,Dhanpat Rai , 2004 , Electrical And Electronic Measurements And Instrumentation, A.K.Sawheney ,Dhanpat Rai , 1993 , A Coursein Electricalpower, Soni, Gupta ,Dhanpat Rai , Latest Edition , Strength Of Materials, S. Ramamrutham ,Dhanpat Rai , 15 Edn 2004 , Course In Electrical Machine Design, A.K.Sawhney ,Dhanpat Rai , Latest Edition , Electrical Technology, B.L.Theraja ,Division Of Nirja Constructions And Dev Co.(P) Ltd , 1994 , Design Data Book, Psg College Of Technology ,Dpv Printers, Coimbatore , Latest Edition , Suftware Testing Concepts And Tools, Nageshwara Rao Pusulri ,Dreamteach , First Edition , Automotive Mechanics, Joseph Heitner ,East West Press (P) Ltd, New Delhi , Latest Edition , Renewableenergy Sources , Twidell, J.W. And Weir, ,Efn Spon Ltd , Latest Edition , Vehicle And Engine Technology, Heinz Heisler ,Elbs , Latest Edition , Programmable Logic Controller, W. Bolton ,Elsevier India Pvt Ltd , Iv Edition , Principles And Practice Of Town And Country Planning, Lewis B. Keeble ,Estates Gazette, University Of Michigan , 2010 , A Text Book On Building Services, R.Udyakumar ,Eswar Press, Chennai , Latest Edition , Fluid Mechanics, K.L.Kumar ,Eurasia Publshing House - New Delhi , Latest Edition , A Text Book Of Machine Design., R.S. Khurmi & J.K.Gupta ,Eurosia Publishing House - New Delhi ,Edn. 18 , Mechanical Measureme Control, R.V. Jalgaonk ,Everes T Publishing House, Pune , Latest Edition , The Cell Phone Handbook, P.J. Stetz And Penelope Stetz ,Findtech Ltd , Second Edition , Pc Repair And Maintenance, Joel Rosenthal ,Fire Wall Media, New Delhi , First Edition 2007 Reprint :2012 , Software Engineering, Bharat Bhusan Agarwal, Sumit Prakash Tayal ,Fire Wall Media, New Delhi , Second Edition 2008 , The Laptop Repair Workbook: An Introduction To Troubleshooting And Repairing Laptop Computers, Morris Rosenthal ,Foner Books , First Edition 2008 , The Laptop Repair Workbook: An Introduction To Troubleshooting And Repairing Laptop Computers, Morris Rosenthal ,Foner Books , First Edition 2008 , Multimedia Technology & Applications,, David Hillman ,Galgotia Publications Pvt Ltd. , Latest Reprint , Repair And Seismic Strengthening Of Buildings - Guidelines, Is:13935 - 2002,,Guidelines, Is:13935 , 2002 , Automotive Mechanics, William H.Crouse And Donald .L. Anglin ,Hill Publishing Company Ltd, New Delhi , Latest Edition , Die Design Fundamentals, Paquin.J.R,,Industrial Press Inc , Latest Edition , Digital And Analog Communication System, B.P.Lathi .Zhi Ding ,International Oxford University Press , 4Th Edition , Mysql Bible, Steve Suehring ,John Wiley & Sons , 2002, Latest Reprint , Modern Production / Operations Management, E.S. Buffa And R.K. Sarin ,John Wiley & Sons , Latest Edition , Remote Sensing And Image Interpretation, Lillesand, T.M. & Kiefer R.W. (1998) ,John Wiley & Sons , Latest Edition , Ground Water Hydrology, David Keith Todd ,John Wiley & Sons , Latest Edition , Digital Communications, Simon Haykin ,John Wiley India Edition , Latest Edition , Cad/Cam, Mikell P.Groover ,Jr.Prentice Hall Of India Pvt., Ltd. , Latest Edition , A Course In Electrical Power, J.B. Gupta ,Kaison Publishing House , Reprint 2004 , Civil Estimating, Costing And Valuation,,Kalson Publishing House , Latest Edition , Machine Drawing, P.S. Gill ,Katsan Publishing House , Latest Edition , Analysis Of Structures – Vol 1, Vazirani & Ratwani ,Khanna Publishers , Latest Edition , Quantity Surveying & Valuation, N.A.Shaw ,Khanna Publishers , Latest Edition , Water Supply And Sanitary Engineering, S.K.Garg ,Khanna Publishers , Latest Edition , Hydrology And Water Resources Engineering, Santhosh Kumar Gar ,Khanna Publishers , Latest Edition , Fluid Mechanics, Prof. S. Nagarathinam - ,Khanna Publishers , Latest Edition , Workshop Technology ,Raghuwanshi,Khanna Publishers , Latest Edition , Production Technology,Nai Sarak ,Khanna Publishers ,Edn. Xii , Thermal Engineering, P.Lballaney ,Khanna Publishers , 24Th Edition , Production Technology, Jain & Gupta ,Khanna Publishers , Latest Edition , Automobile Engineering, G.B.S.Narang ,Khanna Publishers , Latest Edition , Thermal Engineering, P.L Ballaney,Khanna Publishers , 24Th Edition , Applied Thermodynamics, Domkundwar And C.Pkothandaraman ,Khanna Publishers ,2Nd Edition , Non Conventional Energy Sources, G.D. Rai,Khanna Publishers , 1999 , Industrial Engineering And Management, O.P. Khanna ,Khanna Publishers , Latest Edition , Refrigeration And Air Conditioning, P.L . Ballaney ,Khanna Publishers , Latest Edition , Electric Circuit Theory, Dr.M.Arumugam Dr.N.Premkumaran ,Khanna Publishers , Latest Edition , Electrical Power, S.L Uppal ,Khanna Publishers , Latest Edition , Electrical Wiring, Estimating And Costing, Dr.S.L.Uppal G.C. Garg ,Khanna Publishers , Sixth- 2011 , Electric Circuit Theory, M. Arumugam, N. Premkumaran ,Khanna Publishers , 1997 , Power Electronics, P.S.Bimbhra, ,Khanna Publishers , 5Th Edition 1994 , Integrated Circuits, K.R. Botkar ,Khanna Publishers , Latest Edition , Satellite Communication, D.C. Agarwal ,Khanna Publishers , Third Edition , A Monograph On Electronic S Design Principles,, N.C.Goyel, R.K.Khetan, ,Khanna Publishers , Second Edition , Operating Systems, Ekta Walia ,Khanna Publishers , 2Nd Edition , Data Structures, Rs Salaria ,Khanna Publishers , 2016 , Electric Power, Sl Uppal ,Khanna Publishers , Latest Edition , Testing, Commissioning, Operation And Maintenance Of Electrical Equipments, S.Rao ,Khanna Publishers , Sixth Edition, 2010 , Electrical Estimation And Costing, Surjit Singh ,Khanna Publishers , Latest Edition , Power Electronics, Dr.P.S.Bimbhra ,Khanna Publishers , Fourth Edition, 2011. , Mechanical & Indtrial Measuments, R.K.Jain ,Khanna Publishers , Latest Edition , Construction Management, Sanga Reddy. S ,Kumaran Publications, Coimbatore , Latest Edition , Fluid Mechanics, R.K. Bansal ,Lakshmi Publications , Latest Edition , Total Quality Management,, V.Jayakumar ,Lakshmi Publications. , (Reprint 2005) , Thermal Enggi., R.K . Rajput,Laxmi Publications Pvt Ltd , 8Th Edition , Fluid Mechanics And Hydraulic Machines, R. K. Bansal ,Laxmi Publications Pvt Ltd , Latest Edition , Engineering Mechanics, R K Bansa ,Laxmi Publications Pvt.Ltd. , Latest Edition , Building Construction, Dr. B.C. Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Building Construction, Ashokkumar Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Surveying Volume I, Punmia.B.C. Ashok K.Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , 2011 , Theory Of Structures, B.C. Punmia, Ashok Jain & Arun Jain ,Laxmi Publications Pvt.Ltd. , 9Th Edition , Surveying Volume I, Punmia.B.C, Ashok K.Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Surveying Volume Ii & Iii, Punmia.B.C, Ashok Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Limit State Design Of Reinforced Concrete, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , R C C Designs, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Environmental Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Waste Water Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Soil Mechanics And Foundation Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Project Planning And Control With Pert And Cpm, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Buildingconstruction, Dr.B.C.Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Strength Of Materials, R.K. Bansal ,Laxmi Publications Pvt.Ltd. , 3Rd Edition, 2010. , Engineering Mechanics, R.K. Bansal ,Laxmi Publications Pvt.Ltd. , 2Nd Edition, 2007 , Thermal Engg, R.K .Rajput ,Laxmi Publications Pvt Ltd , 8Th Edition , Industrial Robotics – Technology, Programming And Applications, P.Groover ,Mc Graw Hill , 2001 , Mobile Cellular Communications, W.C.Y. Lee ,Mc Graw Hill , Second Edition , Electronic Principles And Applications, Charles.A.Schuler ,Mc Graw Hill , 3Rd Edition, 1989 , Geotechnical Earthquake Engineering Hand Book, Robert W.Day ,Mc Graw Hill , Latest Edition , Measurement Systems Application And Design, Ernest O. Doebelin ,Mc Graw Hill , 2004 , Transducers And Instrumentation, D.V.S.Murty ,Mc Graw Hill , 2004 , Digital Electronics, Roger L.Tokheim Macmillan ,Mc Graw Hill , Latest Edition , Digital Integrated Electronics, Taub & Schlling ,Mc Graw Hill , Latest Edition , Optical Fibre Communication, Gerd Keiser ,Mc Graw Hill , Third Edition , Digital Electronics, Roger L.Tokheim Macmillan ,Mc Graw Hill , 1994 , Computer Control Of Manufacturing Systems, Yoram Koren ,Mc Graw Hill , Latest Edition , Engineering Economics And Management, T.R. Banga & S.C. Sharma ,Mc Graw Hill , Editiion 2 – 2001 , Database System Concepts, Silberschatz A. And Korth H ,Mcgraw Hill Education (India) Pvt Limited , 6Th Edition , A Global Perspective, Heinz Weihrich, Harold Koontz ,Mcgraw Hill International Edition ,10Th Edition , Hessentials Of Management’, Herald Koontz And Heinz Weihrich ,Mcgraw Hill Publishing Company , Latest Edition , Power Electronics, Md Singh, Kb Dhanchandaniata ,Mcgraw Hill Publishing Company , Seventeenth Reprint 2005 , Operating Systems, A Concept-Based Approach, Dhananjay M. Dhamdhere ,Mcgraw Hill, Indian Edition , 3Rd Edition , Elements Of Photogrammetry, Wolf Paul (1998) ,Mcgraw Hill, New Delhi , Latest Edition , Manufacturing Process, Begeman . ,Mcgraw Hill, New Delhi1981. , 5Th Edition , Introduction To Environmental Engineering, Mackenzie, L. Davis And A. David, Cornwell. ,Mcgrawhill , Latest Edition , Environmental Engineering, Peary, Rowe And Tchobanoglous ,Mcgrawhill , Latest Edition , Fundamentals Of Digital Logic With Vhdl Design, Stephen Brown And Vranesic ,Mcgrawhill , Latest Edition , Programmable Logic Handbook: Pld, Cpld, And Fpga, Ashok K.Sharma ,Mcgraw-Hill , Latest Edition , Javascript: The Complete Reference, Powell, Thomas ,Mc-Grawhill , 3Rd Edition , Html & Css: The Complete Reference, Thomas Powell ,Mc-Grawhill , 5Th Edition , Jsp: The Complete Reference, Phil Hanna ,Mc-Grawhill , 2Nd Edition , Robotics For Engineers, Yoram Koren ,Mcgraw-Hill Book Co., , 1992 , “Basic Die Making, Eugene Ostergaard.D ,Mcgraw-Hill Book Company , Latest Edition , Advanced Die Making, Eugene Ostergaard.D ,Mcgraw-Hill Book Company , Latest Edition , Hand Book Of Die Design, Ivana Suchy ,Mcgraw-Hill Book Company , Latest Edition , Tool Engineers Hand Book, Astme ,Mcgraw-Hill Book Company , Latest Edition , Robotics Control, Sensing, Vision And Intelligence, Fu.K.S.Gonzalz.R.C., And Lee C.S.G ,Mcgraw-Hill Book Company , 1987 , Audio And Video System – Principles, Maintenance And Troubleshooting , R.Gupta. ,Mcgraw-Hill Book Company ,Second Edition , Computer Organization, V.Carl Hamacher, Zvonko G.Vransic, Safgat G.Zaky ,Mcgraw-Hill Book Company , 5Th Edition , Elements Of Workshop Technology Volume I & Ii, Hajra Chowdry & Bhattacharaya,Media Promoters & Publishers , Latest Edition , Operation And Maintenance Of Electrical Equipment – Volume I & Ii, B.V.S.Rao ,Media Promoters & Publishers , 1St Edition, 1St Reprint 2011 , Elements Of Workshop Technology- Vol. I & Ii,Hajra Choudry & Battacharya ,Media Promoters & Publishers , Latest Edition , Hydraulic Machines, Jagadishlal, ,Metropolitan Book Company New Delhi , Latest Edition , Fluid Mechanics And Hydraulic Machines, Dr. Jagadish Lal ,Metropolitan Book Company New Delhi , Latest Edition , Mechanical Measurements &Control, D.S.Kumar ,Metropolitan Book Company New Delhi , Latest Edition , Introducing Microsoft .Net, David S.Platt ,Microsoft Press , 3Rd Edition , Computer Organization And Design, David A. Patterson And John L. Hennessey ,Morgan Kauffman / Elsevier , 5Th Edition , Complete Knowledge In C, Sukhendu Dey, Debobrata Dutta ,Narosa Publishing House, New Delhi , Reprint 2013 Or Latest Reprint , Software Testing, K.Mustafa And R.A.Khan ,Narosa Publishing House, New Delhi , Reprint 2009 , Software Quality, R.A. Khan, K.Mustafa And Si ,Narosa Publishing House, New Delhi , Reprint 2008 , Building Materials, S.K.Dugga ,New Age International (P) Ltd , 2003 , Reinforced Concrete Design, N Krishnaraju ,New Age International (P) Ltd , Latest Edition , Design Of R C C And Structural Elements ( Rcc Vol I), S S Bhavikatti, ,New Age International (P) Ltd , Latest Edition , G I S Basics, Shahab Fazal ,New Age International (P) Ltd , Latest Edition , Irrigation And Water Resources Engineering, G.L.Asawa ,New Age International (P) Ltd , Latest Edition , Basic Geotechnical Earthquake Engineering,,New Age International (P) Ltd , Latest Edition , Maintenance Of Buildings, A C Panchdhar ,New Age International (P) Ltd , Latest Edition , Engineeringdrawing And Graphics + Autoca, K.Venugopal, ,New Age International (P) Ltd , Latest Edition , Control Of Machines, S.K Bhattacharya ,New Age International (P) Ltd , Second Edition- Reprint 2010 , Quality Manageme, Narayana.V And Sreeniva N.S ,New Age International (P) Ltd , 1996 , Cad/Cam/Cim, R.Radhakrishnan, S.Subramanian ,New Age International (P) Ltd , Latest Edition , Electrical Power System, Clwadhawa ,New Age International (P) Ltd , Fourth Edition, 2009 , Hvdc Power Transmission System & Technology, Kr. Padiyar ,New Age International (P) Ltd , Reprint 2005 , Digital Protection – Protective Relaying From Electromechanical To Microprocessor, Lp Singh ,New Age International (P) Ltd , Second Edition 1997 , Electrical Design Estimating And Costing, K.B.Raina& S.K.Battacharya ,New Age International (P) Ltd , Reprint - 2011 , Control Of Electrical Machines., S.K. Bhattacharya ,New Age International (P) Ltd , Latest Edition , Power Electronics, Mohammed H.Rashid ,New Age International (P) Ltd , Third Edition,2004 , Programming In C, D.Ravichandran ,New Age International (P) Ltd , 1St Edition 1996, Latest Reprint , Linear Integrated Circuits, D.Roychoudhury & Shail.B. Jain ,New Age International (P) Ltd , 2Nd Edition, 2004. , Modern Television Practice– Transmission, Reception, Applications, R.R.Gulati,New Age International (P) Ltd , 5Th Edition , Monochrome & Color Tv , R.R.Gulati ,New Age International (P) Ltd , Latest Edition , Computer Fundamentals Architecture And Organization, B. Ram ,New Age International (P) Ltd , 5Th Edition , Principles Of Data Structures Using C And C++, Vinu V.Das ,New Age International (P) Ltd , Latest Reprint , Practical Scada For Industry, David Bailey Edwin Wright ,Newness , Latest Edition , Programmable Logic Controllers, W. Bolton ,Newness , Latest Edition , Practical C Programming, Steve Oualline ,O’Reilly , 3Rd Edition , Programming Php, Rasmus Lerdorf And Kevin Tatroe ,O’Reilly Publications , 3Rd Edition , Java, A Beginners Guide, Herbert Schildt ,Oracle Press , 6Th Edition , Pc Hardware In A Nutshell, Robert Bruce Thompson. ,Oreilly Media , Third Indian Reprint 2008. , Principles Of Electrical Machine Design, S.K.Sen ,Oxford & Ibh , Latest Edition , Principles Of Gis For Land Resources Assessment, Burrough P A ,Oxford Publication , Latest Edition , Programming In C, Reema Thereja ,Oxford University Press , 2Nd Edition , Digital Electronics, G.K.Kharate ,Oxford University Press , 2010 , Software Engineering Concepts And Application, Subhasjit Dattun ,Oxford University Press , 2010 , Software Engineering Fundamentals, Ali Behforooz And Fredick J Hudson ,Oxford University Press , 2005 , Reinforced Cement Concrete, Mallick And Rangasamy ,Oxford & Ibh , Latest Edition , Digital Communications Fundamentals And Applications, Bernard Sklar & Pabitra Kumar Ray ,Pearson Education , Latest Edition , Advanced Surveying, Sathesh Gopi, R.Sathikumar & N.Madhu ,Pearson Education , Latest Edition , 8051 Microcontroller And Embedded Systems Using Assembly And C , Mazidi,Mazidi And D.Mackinlay,,Pearson Education , Latest Edition , Programmable Logic Controllers – Programming Methods And Applications, John R Hackworth And Fredrick D.Hackworth ,Pearson Education , Latest Edition , Principles Of Wireless Networks– A Unified Approach, Kaveh Pahlavan And Prashant Krishnamoorthy ,Pearson Education , 2002 , Electronic Communications Systems - Fundamentals Through Advanced, Wayne Tomasi ,Pearson Education , Fifth Edition , Digital Design, M.Morris Mano Michael D Ciletti ,Pearson Education , Latest Edition , 8051 Microcontrollers, Mazidi And D.Mackinlay ,Pearson Education , Latest Edition , Principles Of Wireless Networks – A Unified Approach, Kaveh Pahlavan And Prashant Krishnamurty ,Pearson Education , Latest Edition , Wireless Communications Principles And Practice, Theodore S. Rappaport ,Pearson Education , Latest Edition , Mobile Communications, Jochen Schiller ,Pearson Education , Second Edition , Mobile Cellular Communication, Gottapu Sasibhushana Rao ,Pearson Education , Latest Edition , Operating System, Internal And Design Principles, William Stallings ,Pearson Education , 9Th Edition , Operating Systems, Deitel And Deitel ,Pearson Education , 3Rd Edition , Computer Organization And Architecture Designing For Performance, William Stallings ,Pearson Education , 10Thedition , Network Security Essentials, William Stallings ,Pearson Education , 5Th Edition , Cryptography And Network Security, William Stallings ,Pearson Education , 6Th Edition , Computer Networks, Andrew S.Tanenbaum ,Pearson Education , 5Th Edition , Web Development And Design Foundations With Html5, Terry Felke-Morris ,Pearson Education , 8Th Edition , Software Engineering, Ian Sommerville ,Pearson Education , Sixth Edition , Software Testing Principles And Practices, Srnivasan Desikan, Gopalswamy Ramesh ,Pearson Education , First Edition , Mobile Communications, Jochen Schiller ,Pearson Education , Latest Edition , Fundamental Of Multimedia, Ze- Nian Li And M.S.Drew. ,Pearson Education , 2Nd Edition , Multimedia Computing, Communication And Applications, Ralf Steinmetz And Klara Nahrstedt ,Pearson Education , Latest Reprint , Multimedia Systems, John F. Koegel Buford ,Pearson Education , Latest Reprint , Total Quality Management, Date H.Besterfiled ,Pearson Education Asia. , Latest Edition , Automation, Production Systems, And Computer-Integrated Manufacturing, Mikell P. Groover ,Pearson Education Asia. , Latest Edition , 8051 Microcontroller And Embedded Systems Using Assembly And C, Mazidi,Mazidi And D.Mackinlay ,Pearson Education Low Price Edition. , Latest Edition , Design Of Steel Structures, K.S.Sai Ram ,Pearson-Porling Kindersley Pvt Ltd , Latest Edition , 8051 Microcontroller, Kenneth Ayala ,Penram International Publishing (India) Pvt Ltd , Latest Edition , Plc And Industrial Automation An Introduction, Madhuchhanda Mitraand Samarjit Sen Gupta ,Penram International Publishing (India) Pvt Ltd , Latest Edition , Industrial Energy Conservation-, D. A. Ray- ,Pergaman Press , Latest Edition , Electronics Devices And Circuit Theory, Boyestad & Nashelsky ,Phi , Latest Edition , Electronic Devices & Circuits An Introduction, Allen Mottershed,Phi , Latest Edition , Computer Graphics Multimedia And Animation,, Malay K. Pakhira ,Phi , 2Nd Edition , Principles Of Digital Electronics, K.Meena ,Phi , 2011 , Operational Amplifiers And Linear Integrated Circuits, Robert F. Coughlin Frederick F. Driscoll ,Phi , 1992 , Op. Amp & Linear Integrated Circuits, Ramakant. A. Gayakwad ,Phi , 1992 , Digital Electronics- An Introduction To Theory And Practice, William H.Gothmann ,Phi , 1998 , Transducers And Instrumentation, Dvs Murty ,Phi , 2009 , Measurement And Instrumentation, Arun. K ,Phi , 2010 , Sensor And Transducers, D. Patranabis ,Phi , 2011 , Elements Of Engineering Mechanics, Sanchayan Mukherjee ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Surveying, Mimi Das Saikia, B Mohan Das & M Mohan Das ,Phi Learning Pvt. Ltd., New Delhi. , 2010 , Fundamentals Of Surveying, S. K. Roy ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Structural Analysis, Madhan Mohan Dass, ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Structural Analysis, Madhan Mohan Dass ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Surveying, Mimi Das Saikia, B Mohan Das & M Mohan Das ,Phi Learning Pvt. Ltd., New Delhi. , Edition 2010 , Fundamentals Of Surveying, S. K. Roy ,Phi Learning Pvt. Ltd., New Delhi. , Edition 2010 , Limit State Design Of Reinforced Concrete, P C Varghese ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Limit State Design In Structural Steel, .M.R.Shiyekar ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Principles Of Environmental Science And Engineering,, P.Venugopala Rao ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Irrigation And Water Power Engineering, Madan Mohan Das&Mimi Das Saikia ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Limit State Design In Structural Steel, M.R.Shiyekar ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Buildingconstruction, P.C.Varghese ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Energy Engineering And Management, Amlan Chakrabarti ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Power Electronics, M.S.Jamil Asghar ,Phi Learning Pvt. Ltd., New Delhi. , Eastern Economy Edition, 2010 , Principles Of Digital Electronics, K.Meena ,Phi Learning Pvt. Ltd., New Delhi. , 2009 , Operating System, Principles & Design, Pabitra Pal Chaudhuri ,Phi Learning Pvt. Ltd., New Delhi. , 1St Edition , Computer Organization & Architecture, Rajaraman ,Phi Learning Pvt. Ltd., New Delhi. , Latest Reprint , Fundamentals Of Software Engineering, Rajib Mall ,Phi Learning Pvt. Ltd., New Delhi. , 28Th Printing – August 2011 , A Textbook On C, E.Karthikeyan ,Phi Publication, New Delhi , 2008 , Electronics Devices And Circuit Theory , Boyestad & Nashelsky ,Phi Publication, New Delhi , 2009 , Electronicsdevices And Circuits, Allen Mottershed ,Phi Publication, New Delhi , Latest Edition , Modern Electronic Instrumentation And Measurement Techniques, Albert D.Helfrick And Willam David Cooper ,Phi Publication, New Delhi , 1996 , A Text Book On C, E.Karthikeyan ,Phi Publication, New Delhi , 2008 , Power Electronics, M.H.Rashid ,Phi Publication, New Delhi , 3Rd Edition-2005 , Industrial Electronics And Control, Biswanath Paul ,Phi Publication, New Delhi , 2Nd Edition -2010 , Programmable Logic Controllers, Frank D.Petruzela ,Phi Publication, New Delhi , 2Nd Edition- 1998 , Programmable Logic Controllers Principles And Applications, John W. Webb. Ronald A. Reis ,Phi Publication, New Delhi , Latest Edition , Networks Lines And Fields, John D.Ryder ,Phi Publication, New Delhi , Latest Edition , Electronic Communication, Dennis Roddy And John Colen ,Phi Publication, New Delhi , Latest Edition , Principles Of Digital Electronics, K.Meena ,Phi Publication, New Delhi , Latest Edition , Digital Electronics, William H.Gothmann ,Phi Publication, New Delhi , Latest Edition , Digital Electronics – An Introduction To Theory And Practice, William H.Gothmann ,Phi Publication, New Delhi , Latest Edition , Operational Amplifiers And Linear Integrated Circuits, Ramakant A Gayakwad ,Phi Publication, New Delhi , Latest Edition , Operational Amplifiers And Linear Integrated Circuits, Robert F.Coughlin And Frederick F.Driscoll ,Phi Publication, New Delhi , Latest Edition , Microcontrollers, Principles And Applications, Ajit Pal ,Phi Publication, New Delhi , Latest Edition , Vhdl Primer, Bhasker J ,Phi Publication, New Delhi , Latest Edition , Digital Electronics With Pld Integration, Nigel P. Cook ,Phi Publication, New Delhi , Latest Edition , Digital Logic Simulation And Cpld Programming With Vhdl, Steve Waterman ,Phi Publication, New Delhi , Latest Edition , Data And Computer Communications, William Stallings ,Phi Publication, New Delhi , Latest Edition , Computer Networks , Andrew S.Tanenbaum ,Phi Publication, New Delhi , Latest Edition , Wireless Digital Communications, Kamilo Feher ,Phi Publication, New Delhi , Latest Edition , Wireless Communications And Networks, William Stallings ,Phi Publication, New Delhi , Latest Edition , Irrigation Water Management, Dilip Kumar Majumdar ,Phi Publication, New Delhi , Latest Edition , Multimedia Systems Design., Prabhat K.Andleigh, Kiran Thakra ,Phi Publication, New Delhi , Latest Edition , Performance And Design Of Ac Machines, M.G.Say ,Pitman Publishing Ltd , Latest Edition , Principles Of Management, M.Govindarajan And S.Natarajan ,Prentice-Hall Of India (P) Ltd , Latest Edition , Modern Electronic Instrumentation And Measurement Techniques, Albert D. Helfrick William David Cooper ,Prentice-Hall Of India (P) Ltd , Latest Edition , Building Materials, P.C.Varghese ,Prentice-Hall Of India (P) Ltd , 2011 , Building Constructions, P.C.Varghese ,Prentice-Hall Of India (P) Ltd , 2011 , Geographic Information Systems, Lo & Yeung (2005) ,Prentice-Hall Of India (P) Ltd , Latest Edition , Geographic Information Systems & Environmental Modelling, Clarke Parks & Crane (2005) ,Prentice-Hall Of India (P) Ltd , Latest Edition , Foundation Design, Wayne C.Teng ,Prentice-Hall Of India (P) Ltd , Latest Edition , Operations Research, H.A.Taha ,Prentice-Hall Of India (P) Ltd , Latest Edition , Total Quality Management – An Introductory Text, Paul James ,Prentice-Hall Of India (P) Ltd , Latest Edition , Electronic Device And Circuits- An Introduction, Allen Mottershed,Prentice-Hall Of India (P) Ltd , Latest Edition , Techniques Of Press Working Sheet Metal, Donald F. Eary. & Edward A. Reed ,Prentice-Hall Of India (P) Ltd , Latest Edition , Essentials Of Management, Joseph L.Massie ,Prentice-Hall Of India (P) Ltd , 4Th Edition , Elements Of Electrical Engineering, Maria Louis ,Prentice-Hall Of India (P) Ltd , Latest Edition , Digital Electronics, William H.Gothmann ,Prentice-Hall Of India (P) Ltd , Latest Edition , Programmable Logic Controllers – Principle And Applications, John W. Webb ,Prentice-Hall Of India (P) Ltd , Latest Edition , Computer Networks, Andrew S.Tanenbaum ,Prentice-Hall Of India (P) Ltd , 2002 , Data And Computer Communications, William Stallings ,Prentice-Hall Of India (P) Ltd , Eighth Edition 2007 , Computer System Architecture, M.Morris Mano ,Prentice-Hall Of India (P) Ltd , 3Rd Edition , Data Structures A Programming Approach With C, Dharmender Singh Kushwaha And Arun Kumar Misra ,Prentice-Hall Of India (P) Ltd , 2012, Latest Reprint , Classic Data Structures, Debasis Samanta ,Prentice-Hall Of India (P) Ltd , 2Nd Edition , The Internet, Douglas E.Comer ,Prentice-Hall Of India (P) Ltd , 4Th Edition , Introduction To Biomedical Instrumentation, Mandeep Singh,Prentice-Hall Of India (P) Ltd , Latest Edition , Iso 9001, Brain Rethry, Brain Rethry ,Productivity And Quality Publishing Pvt. Ltd. , 1993 , Surveying And Levelling Part 1 & 2, Kanetkar.T.P. & S.V.Kulkarni ,Puna Vidyarthi Griha, Prakashan , 2008 , Surveying And Levelling Part 1 & 2, Kanetkar.T.P. & S.V.Kulkarni ,Puna Vidyarthi Griha, Prakashan , 23Rd Edition , Limit State Theory And Design Of Reinforced Concrete, S.R.Karve And V.L.Shah ,Puna Vidyarthi Griha, Prakashan , 5Th Edition , A Course In Electrical And Electronics Measurements And Instrumentation, A.K. Sawhney ,Puneet Sawhney Dhanpat Rai & Co (P) Ltd. , Latest Edition , Upgrading And Repairing Laptops, Scott Mueller ,Que Publication , Latest Edition , A Text Book Of Fluid Mechanics And Hydraulic Machines,By, R. K Rajput And S.Chand ,R. K Rajput And S.Chand & Co, New Delhi , Latest Edition , Training Manual On Iso 9001 : 2000 & Tqm, Girdhar J.Gyani ,Raj Publishing House , Latest Edition , Electrical Machine Design, A.Naoor Kani ,Rba Publications , Latest Edition , A Course In Electrical Engineering , B.L.Theraja ,S.Chand & Company Ltd, New Delhi ,Reprint 2006 , A Text Book Of Transportation Engineering, S P Chandola ,S.Chand & Company Ltd, New Delhi , Latest Edition , Strength Of Materials, R.S.Khurmi ,S.Chand & Company Ltd, New Delhi , Latest Edition , Strength Of Materials, R. S. Khurmi, S.Chand,S.Chand & Company Ltd, New Delhi , Latest Edition , Production Technology , P. C. Sharma ,S.Chand & Company Ltd, New Delhi ,Edn. X , Thermal Engineerin, , R.S. Khurmi, J.K Gupta ,S.Chand & Company Ltd, New Delhi , 18Th Edition , A Text Book Of Hydraulics, Fluid Mechanics And Hydraulic Machines,R.S. Khurmi ,S.Chand & Company Ltd, New Delhi ,Edn.18 , Thermal Engineering, R.S. Khurmi And J.K. Gupta ,S.Chand & Company Ltd, New Delhi , 18Th Edition , The Automobile, Harbans Singh Reyat, S.Chand,S.Chand & Company Ltd, New Delhi , Latest Edition , Non Conventional Energy Sources And Utilisation , R.K. Rajput - S.Chand ,S.Chand & Company Ltd, New Delhi , 2012 , A Text Book Of Electrical Technology Volume Ii, B.L. Theraja ,S.Chand & Company Ltd, New Delhi , Latest Edition , A Text Book Of Electrical Technology -Volume Ii, B.L. Theraja ,S.Chand & Company Ltd, New Delhi , Latest Edition , Principles Of Power System, V.K.Metha ,S.Chand & Company Ltd, New Delhi , 4Th Edition Reprint 2007 , Electronic Measurements And Instrumentation, R.K.Rajput ,S.Chand & Company Ltd, New Delhi , 3Rd Edition 2009 , Computer Concepts And C, Dr.S.S.Khandare ,S.Chand & Company Ltd, New Delhi , 1St Edition 2010, Latest Reprint , Electrical Technology Vol I And Ii, B.L.Theraja ,S.Chand & Company Ltd, New Delhi , Mutiple Colour Edition,2012 , Principles Of Electronics, V.K.Mehta ,S.Chand & Company Ltd, New Delhi , Second Edition , Electronics And Instrumentation, Dr.S.K.Battachariya Dr. Renu Vig ,S.K. Kataria & Sons, New Delhi , Latest Edition , Principles Of Electrical Machine Design, R.K.Agarwal ,S.K. Kataria & Sons, New Delhi , Latest Edition , Environmental Engineering And Management, Dr.Suresh K.Dhameja- ,S.K. Kataria & Sons, New Delhi , Latest Edition , Soil Mechanics & Foundation Engineering, V N S Murthy ,Sai Kripa Technical Consultants , Latest Edition , Digital Communications, Dr.K.N.Hari Bhat Dr.D.Ganesh Rao ,Sanguine Technical Publisher , Latest Edition , Energy Resource Management, Kirpal Singh Jogi- Sarup And Sons ,Sarup And Sons , Latest Edition , A Course In Electrical And Electronic Measurement And Instrumentation, Umesh Sinha ,Satya Prakashan, New Delhi , Latest Edition , Electrical And Electronics Measurements And Instrumentation, Umesh Sinha ,Satyaprakashan Tech , 1992 , Theory And Problems Of Machine Design, Holowenko, Laughlin ,Schaum’S Outline Series. , Latest Edition , Data Structures With C, Seymour Lipschutz ,Schaums Outlines, Tmh , Latest Reprint , Microprocessor And Microcontroller, R.Theagarajan ,Sci Tech Publication , Latest Edition , Microprocessor And Microcontroller, R.Theagarajan ,Sci Tech Publication, Chennai. , Latest Edition , Limit State Design Of Concrete Structures, Dr.S.Ramachandra ,Scientific Publishers , Latest Edition , Murach’S Mysql, Joel Murach ,Shroff / Murach , 2012, Latest Reprint , Fundamentals Of Tool Design, Dr.John G.Nee ,Society Of Manufacturing Engineers. , Latest Edition , Electrical Machine Design, C.Eswarlal ,Sonaversity , Latest Edition , A Concise Introduction To Software Engineering, Pankaj Jalote ,Springer, Latest Edition , Design Of Electrical Machine, Mittle V.N ,Standard Book – House , Latest Edition , Fluid Mechanics, P.N. Modi & S.M. Sethi ,Standard Publishers & Distributors, New Delhi , Latest Edition , Water Supply And Sanitary Engineering Vol I & Ii, Gurcharan Singh ,Standard Publishers & Distributors, New Delhi , Latest Edition , Hydraulics, Fluid Mechanics And Hydraulics Machines, K.R. Arora ,Standard Publishers & Distributors, New Delhi , Latest Edition , Automobile Engineering Vol- 1, Vol – 2,Kirpal Singh ,Standard Publishers & Distributors, New Delhi , Latest Edition , Learning Material Development Project,,Taramani, Chennai, Cd Programme On Gps And Gis , Latest Edition , Principles Of Transportation & Highway Engineering, G V Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Environmental Engineering, N.N. Basak ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Environmental Engineering, A.Kamala,D.L.Kanthrao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Engineering Hydrology, K.Subramanya ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Production And Operations Management, S.N. Chary ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Essentials Of Management, Koontz &Weihrich ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Business Correspondence & Report Writing, R.C. Sharma And K.Mohan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , How To Prepare For Group Discussion & Interview (With Audio Cassette), Prasad ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Construction Management And Planning, Sengupta.B, &H.Guha ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Computer Applications In Construction, Boyd.C. & Paulson Jr ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Fluid Mechanics And Machinery, B C S Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Geotechnical Earthquakes Engineering Hand Book,,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Strength Of Materials, S.S.Rattan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Strength Of Materials,B K Sarkar ,Tata Mcgraw-Hill Publishing Company Ltd , I Edition, 2003 , Production Technology,,Tata Mcgraw-Hill Publishing Company Ltd ,Edn. 18. 2001 , Autocad With Applications, Sham Tickoo,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Applied Thermodynami, Pk Nag ,Tata Mcgraw-Hill Publishing Company Ltd , 2Nd Edition , Production Technology, Hmt, ,Tata Mcgraw-Hill Publishing Company Ltd , Edn. 18 , Manufacturing Process, Myro N Begman ,Tata Mcgraw-Hill Publishing Company Ltd , Edn. 5 , Production Processes, Nitttr, ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Circuits & System- Analog And Digital , Y.N.Bapat ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Applied Thermodynamics, P.K. Nag ,Tata Mcgraw-Hill Publishing Company Ltd , 2Ndedition , Quality Management, Howard Cuitlow ,Tata Mcgraw-Hill Publishing Company Ltd , 1998 , Quality Planning And Analysis, Juran J.M And Frank M.Gryna Jr. ,Tata Mcgraw-Hill Publishing Company Ltd , 1982 , Tool Design, Donaldson ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Non-Conventional Energy Resources ,B.H.Khan ,Tata Mcgraw-Hill Publishing Company Ltd ,2Nd Edn, 2009. , Cad/Cam Principles And Applications, Dr.P.N.Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Cad/Cam, Ibrahim Zeid ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Measurement Systems, E. O. Doebelin ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Robotics And Image Processing, Janakiraman.P.A ,Tata Mcgraw-Hill Publishing Company Ltd , 1995 , Circuits And Networks Analysis And Synthesis., A. Sudhakar Shyammohan S Palli ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electric Circuits, Mahamood Nahvi Joseph A Edminister ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Machines, Nagarath ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Machines, Bhattacharya ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices & Circuits, Salivahanan S, N.Suresh Kumar, A.Vallavaraj,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices & Circuits, Jacob Millman And Halkias ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Optical Fiber Communication, Gerdkeise ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Instrumentation, Hs Kalsi ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Modern Digital Electronics, R.P.Jains ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Principles & Applications, Albert Paul Malvino & Donaldp.Leach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Introduction To Microprocessor, Aditya P Mathur ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Power System Protection And Switchgear, B Ram & Dn Viswakarma ,Tata Mcgraw-Hill Publishing Company Ltd , Reprint 2000 , Programmable Logic Controllers, Frank D.Petruzella ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Power Distribution System, As Pabla ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Utilization Of Electric Power, Nv Suryanarayana ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Troubleshooting, Maintaining And Repairing Pcs, Stephen J Bigelow ,Tata Mcgraw-Hill Publishing Company Ltd , 2004 , Data Communication And Networking, Behrouz A.Forouzan ,Tata Mcgraw-Hill Publishing Company Ltd , 2006 , Computer Networks, Achyut Godbole ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices And Circuits, Salivahanan S, N.Suresh Kumar, A.Vallavaraj ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition 2016 , Electronic Principles , Malvino ,Tata Mcgraw-Hill Publishing Company Ltd , 2010 , Electronicsdevices And Circuits, Jacobmillmanandhalkias ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition 2010 , Electronic Instrumentation, Kalsi ,Tata Mcgraw-Hill Publishing Company Ltd , 2004 , Programming In Ansi C , E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Programming And Problem Solving Using C, Isrd Group, Lucknow ,Tata Mcgraw-Hill Publishing Company Ltd , 2008 , Electronic Communication Systems, Kennedy ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Tv And Video Engineering, Arvind M.Dhake ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Communication Electronics Principles And Application , Louis E Frenzel ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Principles And Applications, Albert Paul Malvino & Donald P.Leach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Linear Integrated Circuits, Salivahanan & V.S.Kanchana Baskaran ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Communication Systems, Kennedy – Davis ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Communication, P.Ramakrishna Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Principles Of Communications System, Taub &Schilling ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Computer Installation And Servicing, D.Balasubramanian ,Tata Mcgraw-Hill Publishing Company Ltd , Second Edition 2010 , Troubleshooting, Maintaining And Repairing Pcs, Stephen J.Bigelow ,Tata Mcgraw-Hill Publishing Company Ltd , Fifth Edition , Ibm Pc And Clones, B.Govindrajalu ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Data Communication And Networking, Behrouz A.Forouzan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Tv And Video Engineering, By A.M.Dhake ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Color Tv, Theory And Practice, S.P.Bali ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Modern Digital Electronics, R.P. Jain ,Tata Mcgraw-Hill Publishing Company Ltd , Third Reprint 2010 , Basic Electricall Engineering, V.N.Mittle ,Tata Mcgraw-Hill Publishing Company Ltd , First Edition , Basic Electrical And Electronics Engineering, R,Muthusubramanian R.Salivajanan ,Tata Mcgraw-Hill Publishing Company Ltd , Seventh Reprint 2011 , Computer Architecture And Organization, John P. Hayes ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Data Communication And Networking, Behrouz A.Forouzen ,Tata Mcgraw-Hill Publishing Company Ltd , 5Th Edition , Computer Communications And Networks, Achyuts.Godbole ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Cryptography And Network Security, Behrouza.Forouzen ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Programming With Java, E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , 5Th Edition , Data Structures And Algorithms, G.A.Vijayalakshm I Pai ,Tata Mcgraw-Hill Publishing Company Ltd , 6Th Reprint Or Latest Reprint , Data Structures Using C, Isrd Group ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Reprint , Programming In C#, E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Applications Of .Net Technology, Isrd Group ,Tata Mcgraw-Hill Publishing Company Ltd , 1St Edition Or Latest Reprint , Cloud Computing A Practical Approach 2008 Edition, Cloud Computing A Practical Approach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Software Engineering, Stephen Schach ,Tata Mcgraw-Hill Publishing Company Ltd , Eight Reprint 2011 , Mobile Computing, Asoke K Talukder,Hasan Ahmed, Roopa R Yavagal ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Multimedia: Making It Work., Tay Vaughan ,Tata Mcgraw-Hill Publishing Company Ltd , 8Th Edition , Multimedia Communication Systems: Techniques, Standards, And Networks, K.R. Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Reprint , Principles Of Multimedia, Ranjan Parekh ,Tata Mcgraw-Hill Publishing Company Ltd , 2Nd Edition , The Complete Reference Linux, Richard Peterson ,Tata Mcgraw-Hill Publishing Company Ltd , 6Th Edition , A Text Book Of Engineering Drawing,R.B. Gupta ,Technical India Publications, New Delhi , Latest Edition , Digital Communication, Dr. J.S.Chitode ,Technical Publications – Pune , Latest Edition , Introduction To Plc, Gary Dunning ,Thomson Del Mar Learning , 3Rd Edition , Data Structures Using C – 1000 Problems And Solutions, Sudipta Mukherjee ,Tmgh, New Delhi , 2Nd Reprint Or Latest Reprint , Industrial & Power Electronics, Harish C.Rai ,Umesh Publications , 2017 , Construction Engineering & Management, Seetharaman. S ,Umesh Publications , Latest Edition , Introduction To Earthquake Engineering,,University Of Tokyo Press , Latest Edition , Digital Electronics And Logic Design, Jaydeep Chakravarthy ,University Press, Hyderabad , First Edition2012 , Introduction To Data Structures Using C, Venkatesh N.Baitipuli ,University Science Press, Chennai , 1St Edition, 2009 Or Latest Reprint , Software Engineering, Rohit Khurana ,Vikas Publishing Ltd , Second Edition , Organizational Behaviours, S.Chandran ,Vikas Publishing Ltd , Latest Edition , Operating Systems, Rohit Khurana ,Vikas Publishing Ltd , 2Nd Edition , Workshop Technology, Waj Chapman ,Vima Books Pvt. Ltd New Delhi , Latest Edition , Energy Auditing In Electrical Utilities, Rajiv Shankar ,Viva Books Pvt. Ltd., New Delhi , Latest Edition , Workshop Tech Vol I,Ii, Iii, Waj. Chapman ,Viva Books Pvt. Ltd., New Delhi , Latest Edition , Wireless And Mobile Network Architectures, Yi-Binglin, Imrich Chlamtac ,Wiley , Latest Edition , Wireless Networks, P. Nicopolitidis ,Wiley , Latest Edition , Operating System Concepts, Abraham Siberschatz, Galvin, Gagne ,Wiley , 9Th Edition , Microprocessor Architecture Programming And Application, Ramesh S. Gaonkar, ,Wiley Eastern Ltd , Latest Edition , Introduction To System Design Using Ic, B.S. Sonde ,Wiley Eastern Ltd , Latest Edition , Fundamentals Of Acoustics, Kingsler And Frey,Wiley Eastern Ltd , Latest Edition , Beginning Android 4 Application Development, Wei-Meng Lee ,Wiley India Edition , Latest Edition , Power Electronics, Mohan, Undeland, Robbins. ,Wiley India Edition. , Media Enhanced Third Edition , Web Programming, Chris Bates ,Wiley India, New Delhi, 3Rd Edition , Cloud Security: A Comprehensive Guide To Secure Cloud Computing, Ronald L. Krutz Russell Dean Vines ,Wiley Publishing, Inc , Latest Edition , Cloud Computing Bible, Barrie Sosinsky ,Wiley Publishing, Inc. , Latest Edition , Total Quality Management For Engineers, Zeiri ,Wood Head Publishers , 1991 , Mechanics Of Structures- Vol 1, S.B.Junnarkar , , Latest Edition , I S 2185 Part I & Ii, Ernest O. Doebelin , , Latest Edition , Pwd & Cpwd Specifications, D.V.S.Murty , , Latest Edition , National Building Code,, , Nbc-2012 , Tamilnadu District Municipal Building Rules And By-Laws,, , Latest Edition , Civil Engineering Drawing And House Planning, B.P. Verma , , Latest Edition , Building Planning And Drawings, Dr N. Kumaraswamy And A. Kameswara Rao , , Latest Edition , Building Planning And Construction, G. Vaidhyanathan, I. Kulasekaran, G. Sathish Kumar , , Latest Edition , Civil Engineering Drawing, S.C.Rangwala , , Latest Edition , A Guide To Civil Engineering Drawing, V.R.Thothathri , , Latest Edition , Theory Of Structures, S. Ramamrutham , , Latest Edition , Analysis Of Structures, V.N. Vazirani & M.M. Ratwani , , Latest Edition , Elementary Theory Of Structures, R.L. Jindal , , Latest Edition , Strength Of Materials, Fv. Warnock , , Latest Edition , Estimating & Costing, Bridie , , Latest Edition , Indian Standard Code Of Practice, Is:1200,, , Latest Edition , I S 456-2000 ; I S 875-1987; I S 800 -2007,, , Latest Edition , Explanatory Hand Book Sp24, Design Aid Sp 16,Detailing Of Reinforcement,Sp 34,, , Latest Edition , Concrete Technology , M.S. Shetty , , Latest Edition , Fire Resistant Construction – Building Construction, S.P.Arora And S.P.Bindra , , Second Edition , Earth Quake Proof , Dr.Janardhanjha And Prof.Suresh Kumar , , Latest Edition , Sinha Is Code Of Practice For Earth Quake , Is Code Of Practice For Fire Resistance, Is Code Of Practice For Pre Stressing,, , Latest Edition , Pile Foundation, Rd Chellis, Mis , , Latest Edition , Construction And Foundation Engineering, Sinha & Janatha Shau , , Latest Edition , Principle Fine Safety Standards For Building Construction, M.Ya Roytman , , Second Edition , Remote Sensing And Geographical Information Systems, Anji Reddy.M. (1998) , , Latest Edition , Analysis And Design Of Substructures (Lsd) – Second Edition 2010, Swami Saran , , Latest Edition , Civil Engineering Drawing, M Chakrabort , , Latest Edition , Civil Engineering Drawing, Gurucharan Singh & Subhash Chandar Sharma , , Latest Edition , Civil Engineering Drawing Manual, S Chand & Company (Pvt) Ltd. , , Latest Edition , Production Systems: Planning, Analysis And Control, J.L.Riggs, 3Rd Ed , , Latest Edition , Productions And Operations Management, A.Muhlemann, J.Oakland And K.Lockyer, Macmillan , , Latest Edition , Operations Research, J.K.Sharma, Macmillan , , Latest Edition , Spoken English – A Self-Learning Guide To Conversation Practice (With Cassette),, , Latest Edition , Quality Control And Applications, Housen&Ghose , , Latest Edition , Industrial Engineering Management, O.P. Khanna , , Latest Edition , Steel Structures, Dr.Subramaniam , , Latest Edition , Town Planning, S.C. Rangwala , , Latest Edition , Town Planning, K.S.Rangwala And P.S.Rangwala , , Latest Edition , Remote Sensing Methods And Application, Michael Hord, R , , Latest Edition , National Building Code Of India- Part-Iii.(2005),, , Latest Edition , Municipal And Panchayat Bye-Laws, Cmda Rules And Corporation Bye-Laws.,, , Latest Edition , Urban And Regional Planning, Ka. Ramegowda , , Latest Edition , Earthquake Resistant Design Of Structures, Pankaj Agarwal And Manish Shrikhande , , Latest Edition , Guidelines For Earthquake Resistant Non Engineered Construction, The Associated Cement Companies Ltd , , Latest Edition , Criteria For Earthquake Resistant Design Of Structures - General Provisions And Buildings, Is: 1893 ( Part 1 ) - 2002,, , Latest Edition , Code Of Practice For Ductile Detailing Of Rc Structures Subjected To Seismic Forces, Is:13920-1993.,, , Latest Edition , Earthquake Tips, C.V.R.Murty, , , Latest Edition , Indian Standard Code Of Practice, Is:1200.,, , Latest Edition , Estimating And Costing, Vazirani & Chandolu , , Latest Edition , Geometrical And Machine Drawing, N.D. Bhatt, Anand , , Latest Edition , Hydraulics, Andrew Parr , , Latest Edition , Fundamentals Of Pneumatic Control Engineering, Festo Manual , , Latest Edition , Electrical Technology, Hughes, , 8Th Edition , Machine Design Bandari,,, , Latest Edition , Industrial Engineering & Management, O.P Khanna , , Latest Edition , Industrial Engineering & Production Management, Martand Telsang , , Latest Edition , Production Engineering , P.C.Shrma. , , Latest Edition , Production And Costing, Gbs Narang And V.Kumar , , Latest Edition , Mechanical Estimating And Costing , Banga & Sharma. , , Latest Edition , Quality Auditing, D.Mills, Chapman And Hall , , 1993 , Refrigeration And Air Conditioning, V.K. Jain, , , Latest Edition , Industrial Refrigeration Hand Book, Wilbert F. Steocker , , Latest Edition , A Course In Refrigeration And Air Conditioning , Domkundwar , , Latest Edition , Principles Of Refrigeration, Dossat, , Latest Edition , Electronic Principles , Malvino , , Latest Edition , Microcontrollers, Principles And Applications – Ajit Pal – Phi Ltd., - 2011.,, , Latest Edition , Biomedical Instrumentation ,Anuradha Publications, Chennai, Dr.M. Arumugam , , Latest Edition , Bio Medical Instrumentation And Measurements, Ii Edition., Leslie Cromwell –Fred J. Wibell, Erich A.P Feither , , Latest Edition , Medicine And Clinical Engineering., Jacobson And Webstar , , Latest Edition , Hand Book Of Bio –Medical Instrumentation., R.S .Khandpur , , Latest Edition , Medical Electronics, Kumara Doss , , Latest Edition , Introduction To Medical Electronics, B.R. Klin , , Latest Edition , Introduction To Biomedical Instrumentation , Mandeep Singh Printice Hall India 2010. , , Latest Edition , Digital Communications, John G.Prokais , , 2011 , Biomedical Instrumentation And Measurements, Leslie Cromwell, Fred J. Wibell, Erich A.P Feither , , Latest Edition , Medicine And Clinical Engineering, Jacobson And Webstar , , Latest Edition , Hand Book Of Bio–Medical Instrumentation., R.S .Khandpur , , Latest Edition , Engineering Mathematics - Dr.M.K.Venkatraman, National Publishing Co, Chennai 2. , Engineering Mathematics – Dr.P.Kandasamy & Others, S.Chand & Co Ltd, New Delhi , Physics, Resnick And Haliday–Wisley Toppan Publishers–England , Engineering Physics–B.L.Theraja–S. Chand Publishers , A Text Book Of Sound–R.L. Saighal & H.R. Sarna–S.Chand & Co. , Mechanics–Narayana Kurup–S. Chand Publishers. , Fundamentals Of Physics – Brijlal And Subramaniam. , Fundamentals Of Electricity – D.N. Vasudeva – S. Chand & Co , Non-Conventional Energy Sources – G.D. Rai.- Khanna Publishers , Text Book Of Remote Sensing And Geographical Information Systems – M. Anji Reddy Bs Publications. , Engineering Chemistry – Jain & Jain – Dhanpat Rai & Sons. , A Text Book Of Engineering Chemistry – S.S. Dara – S. Chand Publication. , A Text Book Of Environmental Chemistry And Pollution Control – S.S. Dara – S. Chand Publication. , Engineering Chemistry – Uppal – Khanna Publishers. , Environmental Chemistry – V P Kudesia – Pragati Publishers. , Chemistry Of Engineering Material – C.V. Agarwal, Andranaidu C. Parameswara Moorthy – B.S. Publications. , A Text Book Of Inorganic Chemistry – P.L. Soni – S. Chand Publication. , Rain Water Harvesting – Hand Book – Chennai Metro Water. , Bhatt N.D. And Panchal V.M., “Engineering Drawing”, Charotar Publishing House, 50Th Edition, 2010. , Gill P.S., “Engineering Drawing”, S.K.Kataria & Sons. , Gopalakrishnan.K.R., Engineering Drawing, (Vol.I And Vol.Ii), Dhanalakshmi Publishers, Edition 2 , Venugopal.K, Sreekanjana G, “Engineering Graphics” New Age International Publishers. , K V Nataraajan “A Text Book Of Engineering Drawing” , Besant Agrawal, C M Agrawal “Engineering Drawing”, Tata Mcgraw Hill Education Private Limited. , Barkinson & Sinha, First Year Engineering Drawing, Pitman Publishers. , Communication Skill, Sanjay Kumar Pushp Lata, Oxford University Press , Communication Skill, , Gph Publication , English Communication Teory And Practical, Manoj Kumar Garg, Scholar Tech Press , Little Redbook - Grammar Made Easy, Terry O Brien
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
31.
Public Administrative Department #9983965 AOC
Bids Are Invited For Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Civil Engineer; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Mechanical Engineer; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Electrical Engineer; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Admin; Office Superintendent/ Vigilance Officer; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Medical Officer; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Civil Engineer; Diploma Or Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Mechanical Or Automobile; Diploma Or Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Electrical Engineer; Diploma Or Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Mechanical Engineer; Diploma Or Graduate , Manpower Outsourcing Services - Fixed Remuneration - Finance/Accounts; Tax Related; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Finance/Accounts; Accountant; Post Graduate , Manpower Outsourcing Services - Fixed Remuneration - Food Safety Related; Food Safety Inspector/ Officer; Graduate Or Post Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Technical Supervisor; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Admin; Head Clerk; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Admin; Librarian; Graduate And A Degree In Library And Information Science , Manpower Outsourcing Services - Fixed Remuneration - Finance/Accounts; Account And Audit Related Work; Graduate Or Post Graduate , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Multipurpose Health Worker (Spm); Hsc And Sanitary Inspector Course , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Junior Medical Technologist (Laboratory Technician Services); Bachelor Degree In Chemistry Or Micro Biology Or Bio Chemistry Or Diploma In Laboratory Technician Or Medical Laboratory Te.. , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Staff Nurses; Bsc Nursing Or Diploma In Gnm , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Pharmacist; B Pharm Or Diploma In Pharmacy , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Civil Engineer; Diploma , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Sanitary Inspector; Any Graduate And Diploma Of Sanitary Inspector Course , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Sanitary Inspector; Hsc And One Year Sanitary Inspector Diploma Course Or Health Sanitary Inspector Course Of Iti , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Diploma In Horticulture Or Agriculture; Diploma , Manpower Outsourcing Services - Fixed Remuneration - Admin; Librarian; Graduate , Manpower Outsourcing Services - Fixed Remuneration - It-Technical; It Engineer; Graduate , Manpower Outsourcing Services - Fixed Remuneration - It- Technical; It Hardware Technician; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Electrical Engineer; Diploma , Manpower Outsourcing Services - Fixed Remuneration - Admin; Administrative Operator Or Office Assistant Or Executive Assistant; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Environment; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Veterinary Inspector; Diploma , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Mechanical Engineer; Diploma Or Iti , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Multipurpose Health Worker (Spm); Hsc And Mpw Or Sanitary Inspector Course , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Multipurpose Health Worker (Spm); Hsc And Fhw Course , Manpower Outsourcing Services - Fixed Remuneration - Others; Electrician; Graduate Or Diploma Or Iti , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Multipurpose Health Worker (Spm); Hsc And Basic Fhw Course , Manpower Outsourcing Services - Fixed Remuneration - Admin; Clerk; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Admin; Driver - Lmv; Secondary School , Manpower Outsourcing Services - Fixed Remuneration - Admin; Driver - Hmv; Secondary School , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Multipurpose Health Worker (Spm); Hsc And Basic Mphw Course Or Si Course , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Electrician; Iti , Manpower Outsourcing Services - Fixed Remuneration - Admin; Liftman; Secondary School , Manpower Outsourcing Services - Fixed Remuneration - Others; Office Peon; Ssc Pass , Manpower Outsourcing Services - Fixed Remuneration - Others; Sweeper; 8 Standard Pass , Manpower Outsourcing Services - Fixed Remuneration - Admin; Helper; Ssc Pass , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Sanitary Inspector; Ssc Pass , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Animal Attendant; Ssc Pass , Manpower Outsourcing Services - Fixed Remuneration - Healthcare; Ward Boy; Ssc Pass , Manpower Outsourcing Services - Fixed Remuneration - Total Quantity :
Contract Date: Ref. Documents Contract Value : 130.64 Crore
Local Bodies No of Bidders 179
Contract Date: Ref. Documents Contract Value : 9.99 Lakh
Boards / Undertakings / PSU No of Bidders 7
Maharashtra View Result →
34.
Railways #9806609 AOC
Supply Of Supply, Installation, Testing And Commissioning Of Centralized Kiosk-Type Running Room Crew Management System (Rrcms), Comprising Minimum 19-Inch Ir-Sensitive Capacitive Touch Screen (Full Hd Or Higher) With Toughened Glass, Industrial-Grade Processor, Adequate Ram And Storage For Kiosk Operation, Integrated Biometric Sensor (Fingerprint/Face As Applicable) Compliant With Uid/Standard Protocols, Automatic Token Dispenser, And In-Built Acu (Approval Console Unit) For Rrcms Approvals; Provided With Integrated Hat Camera Module For Monitoring And Record Purposes, Gsm/4G/5G-Based In-Built Internet Connectivity With Ethernet Fallback, Secure Web-Based Rrcms Interfacing For Real-Time Data Synchronization, Reporting, Dashboards, Audit Trails And Review Monitoring; Including Development, Deployment And Customization Of Rrcms Web Application, Android Mobile Application, Central Server Setup With Hosting And Domain, Data Encryption, Role-Based Access Control, Backup And Recovery, Ups/Power Protection, Vandal-Resistant Kiosk Enclosure Suitable For 24?7 Operation, Remote Diagnostics And Maintenance, User Training And Documentation, And Comprehensive Oem Warranty And Technical Support As Per Contract, Conforming To Railway/Cris It And Cybersecurity Guidelines, Make: Techscape Or Any Other Similarsupply, Installation, Testing And Commissioning Of Centralized Kiosk-Type Running Room Crew Management System (Rrcms), Comprising Minimum 19-Inch Ir-Sensitive Capacitive Touch Screen (Full Hd Or Higher) With Toughened Glass, Industrial-Grade Processor, Adequate Ram And Storage For Kiosk Operation, Integrated Biometric Sensor (Fingerprint/Face As Applicable) Compliant With Uid/Standard Protocols, Automatic Token Dispenser, And In-Built Acu (Approval Console Unit) For Rrcms Approvals; Provided With Integrated Hat Camera Module For Monitoring And Record Purposes, Gsm/4G/5G-Based In-Built Internet Connectivity With Ethernet Fallback, Secure Web-Based Rrcms Interfacing For Real-Time
Contract Date: Mar 16, 2026 Contract Value : 8.63 Lakh
Government Departments No of Bidders 1
35.
Defence #9747613 AOC
Bids Are invited for Monthly Subscription Cards , Proposal Register 200 Pages , Main Gate In Out Register 200 Pages , Main Gate Labour In Out Register 200 Pages , Servant Passes Forms 100 Pages Booklet , Technical Refrence Book Neuferts Architects Data , Service Certificate , Form Of Leave Account In A4 Page 10 Pages , Cheque Slip Register 500 Pages , Personal Data Register In Respect Of Civilian Officers 500 Pages , Attendance Register , Construction Account Forms , Pll Ledger Book , Blank White Register 5 Core , Security Officer Rounds Report Register 150 Sheets , Security Supervisor Duty Register 150 Sheets , Security Assistant Round Report Register 150 Sheets , Entry Pass , Entry Pass Register For Outsourcing Employees , Account Cash Book , Do Letter Pad , Unit Visiting Card , Incoming Register , Outgoing Register , Dsr Vol I Ii And Iii , Mml Vol I And Ii , Travel Regulation , Scale For Accomodation , Roi Meg Bangalore Beg Roorkee Beg Kirkee , Ccs Rules Book , Swamy Hand Book , Annual Part Performance Assessment Report Mes Gp C , Annual Part Performance Assessment Report Dgnp Gp C , Annual Part Performance Assessment Report Mes Technical Grade , Annual Part Performance Assessment Report Mes Steno , Annual Part Performance Assessment Report Mes Udc Aao , Inbr 12 Naval Store Manual , Inbr 13 Clothing And Mess Traps Manual , Inbr 14 Naval Victualling Manual , Financial Regulations Vol I , Gfr 2017 , Manual For Procurement Of Goods 2024 Iind Edition , Manual For Procurement Of Consulting Of Other Services , Manual For Procurement Of Works , Classification Hand Book , Financial Regulations Vol Ii , Local Audit Manual , Travel Regulation Hindi , Dpm 2025 Vol I , Dpm 2025 Vol Ii , Unit Thanks Card , Best Wishes Card , Do Letter Dg A4 , Do Letter Dg A5 , Unit Invitation Card , Hod Letter Pad A4 , Daily Parade State Register , Consumable Ledger Pages , Permanent Ledger Pages , Ledger Pll Hard Bound Covers , File Cover , Leave Sanction Register A4 Size 200 Pages , Daily P
Contract Date: Ref. Documents Contract Value : 10.07 Lakh
Government Departments No of Bidders 5
Andhra Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 8,000
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Ref. Documents Contract Value : 79,999
Statutory Bodies & Commissions/Committees No of Bidders 1
Madhya Pradesh View Result →
40.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
41.
Educational and Research Institute #9516366 Technical Bid
Web Application Security Audit, Vulnerability Scanner, Interception With Security Testing Tool With Computer Forensics And Cdr Analysis-01 No. , Web Application Security Audit, Vulnerability Scanner, Interception With Security Testing Tool With Computer Forensics And Cdr Analysis-01 No. (As Per Technical Specifications Mentioned In Annexure I Of Tender Document) , Optional Accessories (If Any) , Installation Charges (If Any) , Other Charges (Commission Etc. - If Any) , Cmc Charges For First Year After Warranty (Optional - Refer Point No. 35 Of Gtc Of Tender Document) , Cmc Charges For Second Year After Warranty (Optional - Refer Point No.35 Of Gtc Of Tender Document) , Cmc Charges For Third Year After Warranty (Optional - Refer Point No.35 Of Gtc Of Tender Document) , Cmc Charges For Fourth Year After Warranty (Optional - Refer Point No.35 Of Gtc Of Tender Document) , Cmc Charges For Fifth Year After Warranty (Optional - Refer Point No. 35 Of Gtc Of Tender Document) , Amc Charges For First Year After Warranty (Optional - Refer Point No. 35 Of Gtc Of Tender Document) , Amc Charges For Second Year After Warranty (Optional - Refer Point No.35 Of Gtc Of Tender Document) , Amc Charges For Third Year After Warranty (Optional - Refer Point No.35 Of Gtc Of Tender Document) , Amc Charges For Fourth Year After Warranty (Optional - Refer Point No.35 Of Gtc Of Tender Document) , Amc Charges For Fifth Year After Warranty (Optional - Refer Point No.35 Of Gtc Of Tender Document)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
42.
Housing Urban and Rular Development #9500162 Technical Bid
Tender For Creation Of Web Portal, Mobile Application, Migration Of Existing Records And Annual Maintenance For Upbocw. - Grievances Redressal System 2 Mobile App 3 a. Compatible with Android b. All relevant features of the website as mentioned abovec. Charges for Hosting of the Mobile App on Android Play Store 4 API Development and Integrations [Per API] 5 Analytics and Reporting 6 Reporting (All workflow and officers) 7 Analytics Dashboard 8 Darpan Dashboard 9 Training 10 End User Training (Onsite All Districts/Divisons) 11 Development of User Manuals in soft copy, Admin guide, SOPs and Video 12 Data Migration 13 Data and Database Migration from Legacy Systems 14 Verification, Validation and Testing of Migrated Data 15 Technical Support 16 Onsite Technical Support Services (for One Year) 17 Business Analyst (1 No)(Charges@per Month) 18 Core developer (5 No) (Charges@per Month) 19 UI/UX Designer (2 No) (Charges@per Month) 20 Database Administrator (2 No) (Charges@per Month) 21 Quality Assurance (2 No) (Charges @ per Month) 22 Graphic Designer (1 No) (Charges@per Month) 23 Telecaller (2 No) (Charges@per Month) 24 Revamping and Maintenance of CESS Portal 25 a. Data Collection Moduleb. Bocw User Modulec. CESS Payer Moduled. Reconciliation Modulee. Integration with the Different Stakeholders. [As requied by Department]f. Integration with the Payment Gateway per Bankg. MIS Reporting 26 Design, Development & Testing of Smart Chatbot Solution [Per CHATBOT]a. Chat Application Developmentb. Trainingc. Testing 27 WhatsApp Business Chat Number (WABA) 28 WhatsApp Messaging Services [Monthly Conversations, each conversation valid for 24 Hrs] [Minimum 2 lakh messages per month for outreach] [Per Month Billing] 29 Cost of Marketing Messages 30 Cost of Service Messages 31 Cost of Utility Messages 32 To manage chatbot implementations, campaigns, information dissemination related to UPBOCW events. schemes, customer support, reports and all other operations/activities.a. Dashboard and Platform Charges b. Service Support 33 API Integration [Per API] 34 Cloud Hosting Environment forCHATBOT and associated Operations [Per Month Billing] 35 CERT-IN Security Audit through one of the CERT-IN empanelled agencies (valid for 6 months or any changes in source code prior to the expiry of this validity) (Two Times in Year) for the components mentioned in Schedule - A [Website + ERP] 36 CERT-IN Security Audit through one of the CERT-IN empanelled agencies (valid for 6 months or any changes in source code prior to the expiry of this validity) (Two Times in Year) for the components mentioned in Schedule - A [Mobile Application] 37 CERT-IN Security Audit through one of the CERT-IN empanelled agencies (valid for 6 months or any changes in source code prior to the expiry of this validity) (Two Times in Year) for the components mentioned in Schedule - B [AI-Powered CHATBOT] 38 Quality Assurance and Performance Testing 39 Wildcard SSL 40 SUB TOTAL [A+B+C] 41 UPDESCO Centage@10% 42 TOTAL [D1 + D2] 43 GST @ 18% 44 GRAND TOTAL [D3 + D4] 45 Task 46 <2> 47 Web Application 48 a. Labour Registrationb. Labour Renewalc. Establishmentd. Schemesi. Matratva Shishu evam Balika Madad Yojanaii. Sant Ravidas Shiksha Protsahan Yojanaiii. Kanya Vivah Yojanaiv. Gambhir Bimari Yojanav. Nirman Kamgar Mrityu evam Divyangta Sahayta Yojanavi. Deen Dayal Upadhyay Chetna Yojanavii. Aapda Sahayta Yojanae. Web Portal Developmentf. Budget Monitoring SystemIncluding entire Workflow(Open Portal/CSC/LEO/ALC/ADLC/DLC/AO/ADMIN/HO/District or Divison Office) 49 Grievances Redressal System 50 AMC for Mobile App 51 a. Compatible with Android b. All relevant features of the website as mentioned abovec. Charges for Hosting of the Mobile App on Android Play Store 52 API Integrations [Per API] 53 Analytics and Reporting 54 Reporting (All workflow and officers) 55 Analytics Dashboard 56 Darpan Dashboard 57 Technical Support 58 Onsite Technical Support Services 59 Database Administrator (2 No) (Charges@per Month) 60 Telecaller (2 No) (Charges@per Month) 61 AMC for CESS Portal 62 a. Data Collection Moduleb. Bocw User Modulec. CESS Payer Moduled. Reconciliation Modulee. Integration with the Different Stakeholders. [As requied by Department]f. Integration with the Payment Gateway per Bankg. MIS Reporting 63 Chatbot Solution [Per CHATBOT]a. Chat Applicationb. Trainingc. Testing 64 WhatsApp Messaging Services [Monthly Conversations, each conversation valid for 24 Hrs] [Minimum 2 lakh messages per month for outreach] [Per Month Billing] 65 Cost of Marketing Messages 66 Cost of Service Messages 67 Cost of Utility Messages 68 To manage chatbot implementations, campaigns, information dissemination related to UPBOCW events. schemes, customer support, reports and all other operations/activities.a. Dashboard and Platform Charges b. Service Support 69 Cloud Hosting Environment forCHATBOT and associated Operations [Per Month Billing] 70 CERT-IN Security Audit through one of the CERT-IN empanelled agencies (valid for 6 months or any changes in source code prior to the expiry of this validity) (Two Times in Year) for the components mentioned in Schedule - P [Website + ERP] 71 CERT-IN Security Audit through one of the CERT-IN empanelled agencies (valid for 6 months or any changes in source code prior to the expiry of this validity) (Two Times in Year) for the components mentioned in Schedule - P [Mobile Application] 72 CERT-IN Security Audit through one of the CERT-IN empanelled agencies (valid for 6 months or any changes in source code prior to the expiry of this validity) (Two Times in Year) for the components mentioned in Schedule - Q [AI-Powered CHATBOT] 73 Quality Assurance and Performance Testing 74 Wildcard SSL [Renewal]
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
43.
Housing Urban and Rular Development #9500159 Technical Bid
Pre Examination Related Work Of Session 2025-26 For Maa Shakumbhari University, Saharanpur (U.P.). - Prepaire Data Base for Internal/SeasonalMarks:Online Submission of Internal/SeasonalMarks.(Quote Rate On Per Paper Code) 2 Prepaire Data Base forDuty list of Invigilator :Duty list of Invigilator, Centre Superintendent, Asst. Centre Superintendent and Flying Squad with their bank details.(Quote Rate On Per InvigilatorBasis) 3 Prepaire Data Base forFinance Department :Cashier/Finance Department Support .(Quote Rate On Per Applicant Basis) 4 Data Conversion DBASE to SQL /Other Language:(Quote Rate On Per RecordBasis) 5 Uploading data of marks sheet and degree to Digilocker.(Quote Rate On Per Certificate Basis) 6 Audit Total Student Record.(audit student records, Firm must ensure the description in the soft copy (digital version) of the record matches the description in the corresponding hard copy (physical version)(Quote Rate On Per Record Basis) 7 Single Window for Student Academic Document Verification Management Systems Through Latest Technology(ABMS).Quote Rate will be basis of available Total Student Record in tothe university.(Quote Rate PerCertificate Basis) 8 • Dedicated server for University application and allied activities.• Dedicated server for online services.(Quote rate per year) 9 Security Audit for web application through Cert-in Empanelled Vendor valid fox six month or any changes in source code (Two times in a year)(Quote Rate On Per Security Audit Basis) 10 Help Desk For Student Grievances :Dedicated Call Center & Help Desk for Applicant .(Quote rate per Task) 11 Provide Supporting Technical Staff for running program.(Quote rate per man month)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Uttar Pradesh View Result →
Contract Date: Feb 09, 2026 Contract Value : 7.50 Lakh
Local Bodies No of Bidders 2
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
47.
Communications and Information Technology  #9443773 Technical Bid
tender for Annual maintenance contract Of Existing Application With Upgradation And Development Of New Module With One Year Technical Support And Biometric Machines And Associated Items For Jalkal Department, Nagar Nigam Kanpur (U.P), 1 Design and Development of Public Grievances Management Module 2 Design and Development of RTI Management Module 3 Design and Development of Legal Cases Management Module 4 Design and Development of Water Tanker Booking Module 5 Design and Development of Pension management Module 6 Design and Development of Attendance Management System using biometric machines 7 Payment Gateway Integration (Per Payment Gateway Per Bank) 8 Charges for SMS (@per SMS) 9 PoS machine integration (per bank) 10 Security Audit of complete application through Cert-in empaneled service provider (Half yearly basis) 11 SSL (Annually) 12 Cloud Services for one year (Detail mentioned in technical proposal) 13 Onsite Technical Support Services (per person per annum) 14 Biometric Machines and associated items with One Year Warranty 15 PoE based Attendance Machine with Face Recognition + EMPROX Smart Card + Pin and Access Control 16 Wired Mesh box for above Biometric Machine 17 8-Port PoE Switch 2 SFP with min 120W Switch 18 24 Port UTP CAT6 Patch Panel with 8 keystone populated 19 UTP CAT6 patch card 1M 20 UTP CAT6 Information Outlet with Surface Mount Box with Shutter 21 UTP CAT6 cable (305 meter) per box 22 Network rack 6U 23 1KVA LI-UPS with 30 min backup 24 Installation of Biometric Devices at each location along with Mounting Cage 25 Data Entry of Employee and Capturing of face image/ fingerprint of each individual employee. (One-time data feeding per employee). At start we will mark 50 data feeding into the system rest shall be marked by the department else additional charges shall be applied on pro-rata basis 26 Total 27 UPDESCO margin@10% 28 Total Cost including UPDESCO margin 29 GST@18% 30 Overall cost including taxes (A+B) 31 AMC Cost 2nd Year and onwards: 32 Work Description 33 <2> 34 AMC cost of Existing Software after Upgradation - Online Water/ Sewer Tax Management System - Online Water/Sewer Connection form and JKK Website (www.jalkalkanpur.in) - PIS and Payroll Management - Role based User Management Module- Development of Dashboard and MIS report mechanism- Upgradation of Water/ Sewer Tax Billing Application.- Upgradation of online application for new water and sewer connections 35 AMC of Android based Mobile application with Google Services 36 AMC of Public Grievances Management Module 37 AMC of RTI Management Module 38 AMC of Legal Cases Management Module 39 AMC of Water Tanker Booking Module 40 AMC of Pension management Module 41 AMC of Attendance Management System using biometric machines 42 Charges for SMS (@per SMS) 43 PoS machine integration (per bank) 44 Security Audit of complete application through Cert-in empaneled service provider per Annum (Twice in a year) 45 SSL (Annually) 46 Cloud Services for one year (Detail mentioned in Sec- III (3) Scope of work) 47 Onsite Technical Support Services (per person per annum) (optional) 48 AMC of Biometric Machines and associated items 49 AMC of Biometric Machines and associated items (Mentioned at Sr. No. B1 to B11inabove Table) after completion of One Year Warranty (@per Annum) 50 Total 51 UPDESCO margin@10% 52 Total Cost including UPDESCO margin 53 GST@18% 54 Overall cost including taxes (C+D)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
50.
Agriculture #9379144 Technical Bid
Supply Commissioning And Installation Of Gc For N2o , Application: Greenhouse Gases I.E. N2o, Co2 And Ch4 Estimation From The Ambient Air And Soil Gases Samples Very Precisely Using Gc , Gc Mainframe: , Gas Chromatograph (Latest Model) With Head Space Sampler (Hss) Interface For Greenhouse Gases Analysis With Simultaneous Detection Of Greenhouse Gases In Air Samples Air Samples [E.G. Nitrous Oxide (N2o), Carbon Dioxide (Co2), Methane (Ch4)] With Suitable Columns And Provision For Automatic Injecting Sample Having The Following Lower And Upper Detection Limits , · Nitrous Oxide (N2o): = 30 Ppb To 10 Ppm (Mdl = 30 Ppb Or Better) , · Carbon Dioxide (Co2): 0.4 Ppm To 0.2% (Mdl = 0.4 Ppm Or Better) , · Methane (Ch4): 0.2 Ppm To 20% (Mdl = 0.2 Ppm Or Better) , Gas Chromatograph That Provides Superior Performance. , · It Have Easy Access To Maintenance And Service Modes System Interface. , · It Have Retention Time Repeatability <0.008 %; Area Repeatability <0.5 % Rsd. , · It Have Hands Free Leak Check And Retention Time Locking. , Column Oven , · Column Oven Can Accommodate Two Column With A Temperature Range From +5°C To 450 °C. , · Set Point Resolution Of 0.1 °C Or Better; , · Must Support Minimum 20 Ramps Or More; , · Maximum Temperature Ramp Rate Of 120 °C / Min Or Better. , · Oven Cool Down From 450 °C To 50 °C Must Be In 4 Min Or Less With Built-In Programmable Oven Cool Down Rate Readily Available To Cater For Columns Of Different Stability. , · Temperature Stability For < 0.01 °C For A 1 °C Ambient Change, Ensuring The Maintenance Of Oven Internal Temperature With Respect To External Fluctuations. , Column Selection: , · Employ A Column Specially Designed For Separating Nitrous Oxide (N2o) From Other Atmospheric Gases Such As A Porapak Q Or Molecular Sieve Column. , · Suitable Columns: 2 Numbers Each To Analyze The Greenhouse Gases. , Pressure/ Flow Control Pneumatics: , · Microprocessor Based Latest Version Gc (With Advanced Pneumatics, Msd Iso 9001 Certified With Large Graphical Lcd Display To View Chromatogram And Built In Gc System Check And Self-Diagnostic Function). , · System Must Have Epc/Afc/Ppc Control For All Injectors And Detectors With Single Point Control Via Software. , · It Must Have The Capability To Install Up To Eight Epc/Afc. , · Automatic Leak Testing, System Must Have Automatized Pneumatic Controls For All Gases Like Carrier Gas, Make Up Gas, Detector Gas, Etc. , · Pressure Set Point And Control Precision To 0.001 Psi. Pressure/Flow Ramps Must Be Minimum Three. , · Future Upgradability Should Be Possible For Other Detectors. , · Head Space Transfer Line Must Be Fully Integrated With Mainframe. , · Complete System Can Be Fully Controlled By Pc Software , · Carrier And Makeup Gas Must Be Selectable To He, N2, H2 And Argon/Methane. , · System Must Have Factory Fitted & Tested For Back Flushing & Column Switching/Changing Along With The System Software Acquires Chromatograms From All The Detectors Simultaneously With One Injection Only. , Auto Sampler: , Head Space Sampler (Hss): , • Typical Area Repeatability <0.7% Rsd. , • Typical Carryover <0.0001%. , • Auto Injector Must Be With Minimum 48 Vials Capacity Or More. , • Overlapping Up To 12 Vials To Maximize Throughput Or Better. , • Multiple Headspace Extraction Mode With Minimum 100 Extractions Per Vial Or More. , • In-Build Vial Shaker. , • Gc Column Selection From 50 To 530 ?M. , • Compatibility With Headspace Vials Of 10 Ml, 20 Ml, And 22 Ml Sizes With Unrestricted Use Of Different Vial Sizes Within A Single Sequence. , • All Temperature Zones (Oven, Valve And Loop, Transfer Line) Have Set-Point Increments In 1 °C With 0.1 °C Resolution For Actual Temperatures. , • Oven Temperature: Ambient +5 °C To 300 °C Or Better , • Valve And Loop Temperature: Ambient +5 °C To 300 °C Or Better , • Transfer Line Temperature: Ambient +5 °C To 300 °C Or Better , • Vial Pressurization Must Be Fully Controlled By The Included Epc/Afc/Ppc. , • Pressure Setpoints Must Be Adjusted By Increments Of 0.001 Psi. , • Flow Setpoints Must Be Adjusted By Increments Of 0.01 Ml/Min. , • Separate Injector Unit For Headspace Sampler , • Should Have A Closed Sampling Design Without Exposure To Atmosphere Or Ambient Temperature. System Must Be Syringeless To Avoid Exposure To Atmosphere/Contamination. System Must Be Controllable Through Software Only. , • Headspace Should Have Automatic Leak Check, Power Saving And Gas Saving Facility. , Browse Interface: , · Touchscreen Browser Interface , · Mobile Access Features/ Remote Control , Upgradability: Quoted Gc Must Be Upgradable With Single/Triple/Qtof/ Quadruple Mass Spectrometer In Future. , Valves And Catalyst: , Suitable Automatic Gas Sampling Valves, Column Switching Valves & Injecting To Column For Desired Gas Analysis. All Gas Control Should Be Epc/Iec/Afc. , • Gas Sampling Valve-1 , • Column Isolation Valve-1 , • Other Valve-2 , • Nickle Catalyst-1 , Injector , · Multi-Port Gas Sampling Valve With Auto Injector Facility From Tedlar Bag Or Gas Tight Syringe And Manual Gas Sample Injecting Facility Should Be There. , · Suitable Injector For Headspace , Detectors : , Flame Ionization Detector (Fid): , · Minimum Detectable Level (For Tridecane): <1.2 Pg C/S Or Better , · Minimum Temperature Should Be 450 °C Or More. , · Linear Dynamic Range >107 Or Better , · Data Rates Up To 1,000 Hz Or Better. , · Must Have The Flameout Detection And Automatic Reignition Capability. , · Fid With Methanizer, Detector Must Be Compatible With All Colums: Packed, Capillary And Molecular , · Able To Control Up To 3 Channels Of Gas, I.E. H2, Make-Up And Air (With Electronic On/Off). The Control Range Are To Be For Air: 0-500 Ml/Min, H2: 0-100 Ml/Min, And Make Up Gas (N2 Or He): 0-50/ 100 Ml/Min. , Electron Capture Detector (Ecd): , · Minimum Detectable Level: <3.8 Fg/Ml Lindane Or Better , · Minimum Temperature Should Be 400 °C Or Better. , · Linear Dynamic Range >5 × 104 With Lindane Or Better , · Data Rates Up To 500 Hz Or Better. Detector Must Be Compatible With All Columns: Packed, Capillary And Molecular , · Able To Supply A Constant Flow Make-Up Gas (N2 Or Ar) For The Inertness Of Ecd Chamber With Flow Control Of 0-200 Ml/Min. , Customizable Specifications: , · Manual Gas Sample Injecting Facility Should Be There. , Data Management And Acquisition System (Pc & Printer): , · Latest Branded Pc With Licensed Ms Office Package, Antivirus, Compatible Pc For Software , · Intel Core I5 Processor, 3Ghz Or Better , · 8.0Gb Ddr Ram Or More , · 1 Tb Hard Disk Storage, 128 Gb Ssd Or More , · At Least 24” Lcd Monitor , · Latest Window Operating System (Professional-10/11) , · At Least 3/4 Lan And 4/5 Usb Port Availability Or Better , · Wireless Keyboard & Mouse , · Laserjet Black & White Printer , Software System: , · Latest Operating System Compatible Workstation, Original Window-Based Licensed Software From The Same Manufacture Only Which Includes Complete Gc Control, Multi-Channel Real Time Chromatographic Data Acquisition And Post-Run Analysis. , · It Should Also Include High Speed Data Acquisition And Bulk Analysis Compatibility, Full Qualitative & Quantitative Processing Functions, Multi-Function Compatibility, Audit Trail, Validation Assistant, System Suitability, Qa/Qc Functions, All-In-One File Configuration For Easy Data Transfer, Customized Report Generator, Networking Capability, Data Management Etc. , · Software Performing Data Analyses At Least As Per Din/Iso/Us-Epa, Calibration, Blank Correction, Data Import, Export, Handling And Reporting, Quality Control Protocols, Computer Based Training. , Necessary Consumables/Accessories: , • Headspace Vials With Caps, Septa And Storage Box (20 Ml)- 200 Quantity , • Headspace Vial Crimper- 1 Quantity (Electronic Which Has Rechargeable Battery Along With Acessories) , • Headspace Vial Decapper- 1 Quantity (Electronic Which Has Rechargeable Battery Along With Acessories) , • Nickel Catalyst (1 Quantity); Tedler Bags (10 Nos) , • A Vial Evacuation System To Evacuate = 10 Sample Vials At A Time. , • Fid Jet- 1 Quantity , • Greenhouse Gas Checkout Sample-1 Quantity , • 12Ft 1/8 2Mm Hayesep Q 80/100 Um- 1 Quantity , • 6Ft 1/8 2Mm Hayesep Q 80/100 Um- 1 Quantity , • Fused Silica Column Deactivated -0.530Mm X 1M- 1 Quantity , • A Purging System To Purge The Vial/Tedlar Bags. , • Hdspc Al Sfty Crmp Cap, Ptfesi, 20 Mm, 100 Pk , • 20Mm Silver Alum Safety Crimp Cap 100 Pk (01 No.) , • 20Mm Tan Ptfe/White Silicone Septa, 100 Pk (1 No.) , • Vial, Hs, Screw, 20 Ml, Clr, 100Pk (01 Nos) , • Hdsp Cap 18 Mm Magnetic Ptfe/Silicone Septa 100Pk (05 Nos) , • Vial, Hs, Crimp, Fb, 20 Ml, Clr, Cert, 100Pk (01 Nos) , • Ergonomic Manual Crimper For 20Mm Caps (01 No.) , • Ergonomic Manual Decapper For 20Mm Caps (01 No.) , • Gastight Syringes (Ptfe Lucerlock With Needle) Of 500 ?L And 1000 ?L (1 Nos Each) , • Gastight Syringes (Ptfe Luerlok Syringe) Of 25 Ml And 50 Ml (1 Nos Each) Along With Three Needles With Each Syringe. , · Calibration Gas Cylinders: -Calibration Gas Cylinders (10 L Each) Along With Double Stage Ss Regulators For Each Cylinder With Below Concentrations: , N2o (Ppb)Co2 (Ppm)Ch4 (Ppm) Cylinder 1100350 1.5 Cylinder 23001000 6.0 Cylinder 3 1000 20001000.0 , Accessories For Gc Operation: , Gas Cylinders: , • Complete Gas Supply System With 47L Capacity Gas Cylinders For Each Of H2, H2, Zero Air And Ar (95%) + Ch4 (5%) Gas Mixture. , • Hydrogen Gas Cylinder With Gas Purification Panel And Double Stage Regulator- 1 Quantity , • Nitrogen Gas Cylinder With Gas Purification Panel And Double Stage Regulator- 1 Quantity , • Zero Air Gas Cylinder With Gas Purification Panel And Double Stage Regulator- 1 Quantity , • 5% Ch4 In 95% Argon Cylinder For ?Ecd Makeup Gas , • Double/Single Stage Gas Regulators And Gas Purification Pane; With Complete Tubing And Gas Regulation System For All 4-Gases: H2, H2, Zero Air And Ar (95%) + Ch4 (5%) Gas Mixture. , Ups: Branded Compatible Online Ups Of 5Kva With 30 Min. Backup Or Better. , Air Conditioner (Ac): Branded 1.5 Ton Split Ac With Timer , Power Requirement: 220/240 Volt; 50/60 Hz , Warranty: , · Onsite Warranty One Year On Instrument Including Pc, Printer And Ups. , Safety & Regulatory Certificate: , · The System Should Accompanied With Conformity Certificate. , · Quoted Model System Should Be Latest With Good After Sales Support And Should Have Iso 9001 Approval Certificate. Model Must Be Iso/Ce Certificate Or Other Relevant Certificate. , Pre-Installation Requirements All The Necessary Pre-Installation Requisites Required For The Complete Installation Of The System. , Note: , 1. Original Brochure Of The Quoted Model Should Be Submitted. Specification Claimed For Each Component Must Be Supported By Printed Literature Of The Company. The Submitted Printed Literature Must Also Be Available On The Oem Website For Cross-Checking The Specifications And Its Compliances. , 2. Country Of Origin And Manufacture Should Be Mentioned. , 3. Quoted Model Must Be Factory Fitted With Valves, Column & Detector And Tested For Greenhouse Gas And Trace Gas Analysis , 4. Offered Specs Should Be Mentioned In The Original Detailed Technical Catalogue Of The Quoted Model. , 5. Original Brochure Of The Firm To Be Supplied And Same Should Be Reflected In The Website Of The Firm. , 6. Provide Compliance Statement Sheet With Technical Bid And If There Is Any Deviation In Above Mentioned Specifications Should Be Clearly Highlighted In Remarks. , 7. Quoted Model System Should Be Latest With Good After Sales Support And Should Have Iso 9001 Approval. , 8. Entire System Should Be Provided Directly By The Manufacturer And In No Case Local Components Will Be Accepted Except Laser Printer, Pc And Ups Which Can Be Provided From Local Sources. Technical Bids With Compatible Modules From Another Manufacturer Will Not Be Evaluated. , 9. Minimum 10 Installations Of Quoted Model In National R&D Institutions For The Past 5 Years With Supporting Documents Of Purchase Orders/Latest Service Reports/Installation Reports To Be Enclosed. , 10. Original Software For The Equipment Should Be Provided And Free Up-Gradation Of Software During The Warranty Period. , 11. Performance Certificates Of The Quoted Model To Be Attached , 12. Anything Extra Required For Installation Should Be Quoted Along With Instrument. , 13. Warranty And Maintenance , A) The Complete Instrument Should Be Under Warranty At Least For A Period Of One Year From The Date Of Installation. , B) In Case Of Breakdown During The Warranty Period, A Competent Service Engineer Of The Supplier Should Make As Many Visits As Are Necessary To Rectify The Problem And Replace The Faulty Parts, Without Any Liability Of Cost. But It Should Be Repaired Within 72 Working Hours From The Date And Time Of Complaint Lodged By The User. , C) Annual Maintenance Contract (Amc) And Comprehensive Maintenance Contract (Cmc) Quote The Cost Of Onsite Annual Maintenance For At-Least Three Years After Warranty Period (Optional). , 14. Spare Parts The Supplier Of The Instrument Must Confirm In Writing That The Spares For The Entire Instrument Will Be Available For A Period Of At Least 7-10 Years After The Model Of Equipment Supplied Has Been Phased Out. For Frequently Required Spares, There Should Be Adequate Inventory With The Indian Agency. , 15. List Of Service Staffs And Centers Available In India. , 16. On-Site Installation Should Be Provided Free Of Cost. Onsite Training/Demonstration To The Scientists To Be Provided At No Additional Cost. , 17. Manual: One Set Of Operating Manual And Service Manual Including Detailed Drawings And Circuit Diagrams (In English) Should Be Provided With The Instrument. , Quotations Should Be Complete In All Respects At First Instance; Incomplete Quotations And Quotation Of Firms, Who Merely Cut Paste Specifications From Tender Document Are Liable To Rejection. , Gst, If Applicable , Other Charges , Total Bid Price Including All Taxes And Other Charges , (Total Bid Price In Rupees(In Figures)----------------------------------- , (In Words)---------------------------------------------------------------------------------- , Signature Of Bidder
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
TenderDetail
Loading tenders