View Bid Results For Running Track Tenders

We found 1044 Bid Results related to running track tenders. You can find Contractor details who won running track tenders along with contract details in Bid awards announcements section.

Filters
Stage
813
141
90
Tender Publishing Platform
168
876
State / UT
34
311
120
70
52
51
50
37
28
28
26
24
24
23
23
22
20
19
19
16
16
15
7
6
6
5
4
4
4
3
3
3
2
2
1
Contract Value
266
208
413
155
Publish Date
4
0
0
0
0
Sector
26
240
202
151
100
75
66
53
28
25
22
16
15
8
6
5
5
5
4
4
3
3
3
2
1
1
1
Ownership
5
544
249
157
92
2
Within keyword
Active filters:
Showing 1–21 of 1044 tenders matching your filters
1.
Defence #11478095 Technical Bid
Tender For Provision Of Certain Revenue And Minor Work At Age B/R Ii Under Ge(N) Patiala=- 1 Dismantling, Floor, Hearth Or Wall Tiling Including Cm (Bedding (But Not Backing), Removing Serviceable Tiles To Store & Rubbish Off The Premises Complete All As Specified And Directed 2 M&L For Single Charge, Vitrified, Stain & Scratch Resistant, Premium Quality Coloured Tiles Area Of Each Tiles Exceeding 0.42 Sqm But Not Exceeding 1.00 Sqm, In Floors Etc Mm And 8-10 Mm Thick, In Any Pattern Of Light & Dark Tiles As Approved, Laid Over 15 Mm Thick Screed In Cm (1:6) Epoxy Cartridge Tile Grout Using Filling The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour,Complete All As Specified And Directed. 3 All As Per Item No 2 Above But As In Skirting Over 10 Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. 4 M&L For Ceramic Glossy Finish, Joint Free Premium Quality Coloured Tiles 600 X 300 Mm And 8-9 Mm Thick, In Any Pattern Of Light & Dark/Highlighters Tiles Etc As Approved, On Vertical Surfaces Such As In Skirting/Dado Etc, Set And Including 10 Mm Thick Rendering In Cement Mortar (1:4) And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 5 M & L For 15 Mm Thick Artificial Granite (Of Any Type) Work Steps, Jambs, Pillars, Window- Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite. Including Screed Bed Or Bedding Layer Of Mortar 20 Mm Thick For Laying Floor Finishes Complete All As Specified. 6 Providing And Laying Premium (1St) Quality Straight Edge, Ceramic Tiles Exterior Grade Scratch Resistance Of Size 300X300X7 To 8 Mm Thick In Floors Etc. In Any Shade And Design/Pattern Of Light & Dark Tiles Etc Set And Including 15 Mm Thick Rendering In Cement Mortar (1:6) And Pointed In White Cement With Pigment To Match Complete All As Specified. 7 Taking Up Or Down Existing Steel Tubing And Connections, 15Mm Bore Complete All As Specified. 8 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 15Mm Bore Incl Fittings Complete All As Specified And Directed. 9 Taking Up Or Down Existing Steel Tubing And Connections, 20Mm Bore Complete All As Specified. 10 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 20Mm Bore Incl Fittings Complete All As Specified And Directed. 11 S&F In Repair Angle Stop Cock With Wall Flange 15Mm Cast Copper Alloy, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No-Fon-40053Pm Or Equivalent In /Hindware/Kohlar. 12 S&F In Repair 15 Mm Bore Bib Cock With Wall Flange, Cast Copper Alloy, Chromium Plated, Fancy Type With Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No Opp-15037Pm Or Equivalent In/Hindware/Kohlar. 13 S&Fin Repair Brass Chromium Plated Basin Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar Cat Part No Orp-10011Bpm Or Equivalent In /Hindware/Kohlar 14 S&F In Repair 15Mm Cp Connection 600Mm Long Including Washer And Brass Nuts All As Specified. 15 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 16 S&F In Repair Counter Top Wash Basin Of Size 600 X465Mm With Wash Basin Cabinet Size 600X455X600Mm Including Bottle Trap , Brass Waste Fitting Complete All As Specified. Make:-Cera/Hindware/Jaguar 17 S&F In Repair Toilet Roll Holder Stainless Steel Flap All As Specified. Make- Jaquar Cat Part No Can-1153S Or Equivalent In /Hindware/Kohlar 18 S&F In Repair Towelrack 600Mm Long With Lower Hanger (Stainless Steel) All As Specified.(Make: Jaquar Cat Part No Acn -1181S Or Equivalent In /Hindware/Kohlar 19 S&F In Repair Soap Dispenser With Glass Bottle (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1135N As Equivalent /Hindware/Kohlar 20 S&F In Repair Soap Dish Holder With Glass (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Akp -35731P Or Equivalent In /Hindware/Kohlar 21 S&Fin Repair Towel Ring Square With Round Flange (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1121N Or Equivalent In /Hindware/Kohlar 22 S&F In Repair Healthfaucet With 1Mtr Long Easy Flex Tube In Chrome Finish And Wall Hook Of 15 Mm Bore With Cp Pipe Complete Set Of Make -Jaquar Cat Part No Ald - 565 Or Equivalent In Parryware/Prayag 23 S&F In Repair Looking Mirror 5Mm Thick Size 3.5X3.5 Feet Incl Stud And Fastners Complete All As Specified And Directed. 24 S&F In Double Arm Wall Mounted Reversible Plain/Magnifying (X3) Pivotal Mirror All As Specified. Jaquar Cat Part No Acn -1193N Or Equivalent In /Hindware/Kohlar 25 S&F In Repair Glass Shelf Corner With Bracket Of Size 225Mm X 225Mm Thickness Of Glass 6Mm) With Cp Brass Railing And Brass Screws.Make- Jaquar Cat Part No Acn -1173 Or Equivalent In /Hindware/Kohlar 26 S&F Grating Doom 125Mm Of Ptmt. 27 S & F In Repair Vitreous China Urinal Half Stall Type White (Excluding Flushing Cistern ) Including Waste Fitting, Waste Pipe Complete All As Specified.Make-Jaquar/Hindware/Kohlar 28 S&F Ms Work In Tubular/Pipe/Angle Sections For Frame Work For Roof, Vertical Poles, Rafters And Purlins Including Washer Etc Complete All As Directed. 29 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. ( Design Of Sheet As Mangalore Tiles Pattern In Red Colour ). 30 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. 31 M & L Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Incl Preparation Of New Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. 32 M&L 25Mm Thick Factory Made Coloured Interlocking Designer Polished Floor Tiles (Ultra Pattern) Of Grade M-35 Of Shape And Size As Directed,And 100Mm X 100Mm Size Tiles Piece On Every Joint Of Tiles Flooring Laid Over & Including 20Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And Directed . Note: Sample Shall Be Got Approved From Ge Before Commencement Of Work 33 S&F In Repair Stainless Steel Drapery Rod Of 20 Mm Inner Dia (In Lengths As Directed) Of & Including Decorative Finial At Both Ends And Pair Of S S Steel Brackets Fixed At Both Ends With Pvc Rawl Plug & Steel Screws On Walls/Beam, (Victorian Design)All As Specified & As Directed. Make -Sample Can Be Seen In The Office Of Engg-In-Charge For Checking And Quoting The Same 34 Demolition Of Cement Concrete Un -Reinforced In Ground Floors And Pavings N.Exc 15Cm Thickness Complete All As Specified. 35 M& L For 25Mm Thick Pcc 1:2:4 Type Bo Using 12.5 Mm Graded Stone Aggregate As In Floor Complete As Specified And Directed. 36 S & F 75 Mm Dia Pvc ( Swr ) Floor Trap, Plain With Grating Including Jointing With Solvent Cement Complete All As Specified. 37 S & F Floor Door Stopper Of Aluminium Alloy And Tongue, Anodised With Hard Drawn Steel Overall Length Of Cover Plate 140Mm.As In Repairs Complete All As Specified. 38 Dismantling Of Wall And Ceiling Board(Fiblre, Pulp, Insulation Etc) Any Thickness Including Cover Fillets Complete All As Specified And As Directed. 39 S & F Powder Coated Aluminum Alloy Interlocking Snap Grid Frame Work For False Ceiling Size 600Mm X 600Mm Consists Of Main Tee Runners Of Size 38Mm X 38Mm X 1.5Mm And Cross Tee Of Size 38Mm X 38Mm X 1.5Mm, Spaced Between The Main Tee At 600Mm Centre To Centre To Form A Grid Of 600Mm X 600Mm Complete All As Specified And As Directed And As Per Manufacturer. Instruction. 40 M & L For 4Mm Thick Non Asbestos Fibre Cement Building Boards Of Make E Board Classic Designer Board (Cascade Or Occenic) Of M/S Everest Industries Ltd Or Equivalent As Approved, By Ge Fixed Or Laid/ Inserted To Timber/Gi/Aluminium Framework With Complete All As Specified And As Directed. 41 Taking Down Cement Mortar Plastering On Brick Or Stone Walls, Etc. Including Raking Out Joints,Hacking For Key,Scrubbing Down With Water, Etc Complete All As Specified And As Directed. 42 M&L For Rendering 15Mm (In Two Layers 10Mm+5Mm) Thick Plaster In Cm (1:4) On Faces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 43 M&L For Rendering 5Mm Thick Plaster In Cm (1:3) On Faces Of Brick Work Or Concrete On Surfaces Of Ceiling, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 44 Complete Removal Of Existing Treatment Including Washing Rubbing Down And Stopping Of Painted Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 45 M&L For New Plaster Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 46 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 47 M & L For Cement Concrete As Pcc 1:5:10 Type E-2 Using (40Mm Graded Stone Aggregate) As Foundations,Filling And Mass Concrete Complete All As Specified. 48 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 49 Demolition Of Brick Work Or Stone/Boulder Masonary, Laid In Cement Mortar Or Cement Lime Mortar Complete All As Specified. 50 M&L Brick Work, Straight Or Curved On Plan N.Exc 6M Mean Radius In Cm 1:6 Using Old Size Brick Complete All As Specified. 51 Taking Down Chowkat Or Frame With Shutters (With Out Taking Off Shutter From The Frame ) Not Exceeding 1.5 Sqm Each As Directed By Engineer-In-Charge. 52 S&F For Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door Frames/Chowkhat Comprising Of 100 Mm X 65 Mm Size, Applying Pvc Solvent Cement And Screwed With Full Body Threaded, Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg/Cum And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant And Fixed In Position With Mild Steel Hold Fast/Lugs/Ss Dash Fasteners Of Required Dia And Length Complete All As Specified And As Directed By Engr-In-Charge. 53 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Solid Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 54 S&F Stainless Steel (304 Grade) Finished Butt Hinges 125Mm Complete All As Specified And Directed 55 S & F Extruded Brass Handles, Fabricated Type Polished 150 Mm Complete All As Specified. 56 S & F Brass , Barrel Tower Bolts, With Cast Or Sheet Barrel And Rolled Or Cast Bolts And Fixed 200 Mm Complete All As Specified. 57 M&L For 250Mm Long Brass, Sliding Door Bolt Withsand Or Die-Cast Brass Hasp, Staple (Bolt Type) And Fixing Bolt With Rolled Or Drawn Brass Bolts And Fixed Complete All As Specified And As Directed. 58 Dismantling Pvc Pipes With Fittings Upto 75Mm To 110Mm Dia Complete All As Specified And Directed By Engr-In Charge.. 59 S&F For Pvc (Swr) Pipe 110 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 60 S&F For Pvc (Swr) Pipe 75 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 61 S&F For Pvc (Swr) Bends With Access Door 110 Mm Dia Complete All As Specified And As Directed. 62 All As Per Item No 61 Above But 75 Mm Dia. 63 S&F Pvc (Swr) Plain Bend 110 Mm Dia Complete All As Specified And As Directed. 64 S&F Pvc (Swr) Plain Bend 75 Mm Dia Complete All As Specified And As Directed. 65 S&F Pvc (Swr) Branch Piece Single Or Double T Equal Or Unequal With Access Door 110 Mm Dia Complete All As Specified And As Directed. 66 All As Per Item No 65 But 75 Mm Dia. 67 S&F Pvc (Swr) Vent Cowl 110 Mm Dia Complete All As Specified And As Directed. 68 Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering, And Removing Surplus Soil To A Distance N Exc 50 M And Making Good Surface 69 M&L For Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc. And Making Good, Cutting Not Exc 10 Cm Girth All As Specified. 70 Taking Down Carefully Existing Points Wiring On Surface Conduit/Concealed Conduit Including Conduit From Surface And Expect Conduit In Concealed Wiring For Light/Fan/Socket/Power/Bell From Wall & Roof Along With Fitting And Fixtures Such As Switches, Sockets, Ceiling Roses, Batten Holders, Unserviceable Light Fittings, Pieces Of Wires, Gutties, Conduit, Wooden Boards Etc Removing Materials To Store For Keeping In Safe Custody Of Contractor For Which The Credit Has Been Considered Under Schedule Of Credit And Making Good The Disturbed Portion Of All Floor, Ceiling Etc All As Specified And Directed. 71 M & L For Point Wiring With 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor For One Light/Fan/Bell Point In And Including New Pvc Rigid Non Metallic Concealed Conduit 19/20 Mm Dia, Medium Duty, Isi Marked To Be Terminated In Pressed Steel Terminal Boxes With Pvc Modular Top Cover Plates Of Suitable Size For Mounting Of Modular Type Switches/Sockets/Regulators Including 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Earth Continuity Conductor Controlled By One Switch And/Or One Regulator Complete Including Cutting Chases And Making Good The Surfaces In Cm 1:3 And Finishing The Surface As Per Existing Treatment All As Specified And Directed By Engr-In-Charge.Notes: (I) Cost Of Pressed Steel Terminal Boxes And Modular Top Cover Plate Shall Be Included In Point Wiring. (Ii) Wiring Shall Be Done As Per Colour Code In Is For Phase, Neutral And Earth.(Iii) -Cost Of Eye/Bottle Thimbles Used For Connection In Switches/Sockets & Mcbs In Dbs Shall Deemed To Be Included In The Unit Rate Quoted For This Item. 72 All As Per Sl Item No 71.00 Above Herein Before But One Socket Out Let 5 Pins 5 Amp On The Same Board With Other Switches Complete All As Specified And Directed. 73 All As Per Sl Item No 71.00 Above Herein Before But For One Socket Out Let 5 Pins 5 Amp On Independent Board Complete All As Specified And Directed. 74 All As Per Item No71.00 Herein Before But 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor Incl 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Copper Earth Wire For Switch Socket Combination 3 Pin 15 Amps On Independent Board. 75 S & F In Replacement Of Modular Switch 1 Way, 6 Amps, 1 Module, 230 Volts Complete All As Specified. 76 S & F In Replacement Of Modular Switch 1 Way, 16 Amps, 1 Module, 230 Volts Complete All As Specified. 77 S & F In Replacement Of Modular Socket 5 Pin 6 Amps, 2 Module 230 Volts Complete All As Specified. 78 S & F In Replacement Of Modular Socket 5 Pin 6 &16 Amps, Combination Type 2 Module Complete All As Specified. 79 S & F In Replacement Of Modular Fan Regulator Step Type, 120 Watts, 2 Module Complete Fixed As In Repair All As Specified. 80 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 81 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Green Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 82 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Red Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 83 Supply And Fix Surface/Recess Mounted Led Luminaire 36 Watt Cool White 4000-5000K Suitable For Gridd Celling Cutout Dimensions: 2X2 Ft. Incl Connecting With Twin Core Copper Wire From Ceiling Rose To Fitting, Fixture Size: (Lxwxh) In (595X595X65) Mm Incl Lamp And Driver All As Specified & Directed. 84 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 18/20W 6500K Of Capacity ,20 Watt,4 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 85 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 86 Supply And Fix Mirror Light With Linear & Compact 12 W Mirror Light With Decorative Grey End Caps, Polycarbonate Body And Ribbed Opal Diffuser Of Capacity 9 Watt Complete All As Specified And Directed By Engr-In-Charge. 87 M & L For Sub Main Wiring With Two Single Core 4.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 4 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2 Runs Of 4.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 4.00 Sqm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note2 : Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces, Cutting Not Exc. 10 Cm Girth . (Iii) Taking Out/Down Existing Unserviceable Sub Main Wiring. 88 Taking Down And Refixing Of Ceiling Fan After Supply And Replacement Of Rubber Reel, Round Cover Plate Of Size 6 Inch Of Ceiling Fan Complete With Ms Split Clamp Two Nos, Nuts And Bolts Complete All As Specified And Directed By Engr-In-Charge. 89 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 250 Mm Sweep 900 Rpm Engineering Thermoplastic Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Louver Complete All As Specified And Directed By Engineer-In-Charge. 90 Material And Labour For Making Hole Of Suitable Size For Exhaust Fan 250 Mm/ 300Mm Sweep In Wall For Grouting And Making Good The Surface Complete All As Specified And Directed By Engr-In-Charge. 91 Supply And Fixing Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With Mcb Spn 32 Amps, Complete All As Specified And As Directed By Engineer-In-Charge. 92 S&F Poly Coated Gi Frame Work As In Grid For False Ceiling Comprising Of Protected Gi Perimeter Channel 0.55 Mm Thick With Two Unequal Flanges Of 20 And 30Mm And Web Of 27Mm Fixed To Surrounding Wall Using Nylon Sleves And Screws At 450Mm Centre To Centre/Intermediate Chaqnnel 0.9Mm Thick Having To Equal Flanges Of 15Mm Each And Web Of 45 Mm Suspended From Soffit And Approx 900Mm Centre To Centre With Gi Cleat And Steel Expansion Fasterners With And Including Ceiling Section (Not Exc 1.2 Metre Length) Of 0.55Mm Thickness Having Kurled Web Of 50Mm And Flange Of 26Mm Each With Lips Of 10.5Mm Fixed To The Intermediate Channel With Connecting Clips Acorss The Intermediate Channel At 457Mm Centre To Centre And Hangers 6Mm Dia Gi (Upto 1200 Mm Length Adjusting Level Fixed To Roof Slabs By Means Of Ceiling Cleats Made Out Of Gi Flat 40 X3Mm Size 60Mm Long Complete With And Including 7Mm Thick Pvc Laminated Gypsum Tiles Of Size 595X595Mm Complete All As Specified & Directed 93 M&L For Complete Removal Of Existing Surfaces Of Walls Including Cornices, Pillasters Etc, And Applying Two Coats Of Obd Over And Incl A Coat Of Interior Wall Primer Over Wall Care Putty Complete All As Specified And Directed. 94 M&L For Complete Removal Of Existing Treatment On Walls And Applying 02 Coats Of Exterior Weather Emulsion Paint To External Walls/Rcc Surfaces/Soffits Of Chajjas/Roof Projections/Cantilevers/Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer And Over Wall Care Putty Complete All As Specified. 95 S&F Stainless Steel Tubing Of 25 Mm Dia Chromium Plated Min. 1.0 Mm Wall Thickness As In Curtain Rod Complete Incl S&F 02 Nos Stainless Steel Brackets/Finials Fency Type, Stops Fixed With Ss Screws Etc All As Specified & Directed.Note : For The Purpose Of Mesurement And Payment Running Length Of Curtain Rod Only Shall Be Considered. 96 Taking Down Chowkhats Or Frames Of Any Description Exc 1.5 Sqm And N. Exc. 4 Sqm Each (Without Taking Off Shutters From The Frame) Including Cutting Hole To Size For Receive Fresh Pcc Of Hold Fast And Making Good The Disturbed Surface Same Complete All As Specified And Directed. 97 S&F Factory Made Pressed Steel Frames Made Of Ms Sheet Of 1.20 Mm Thickness For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete As Specified,Size 125X60Mm 98 M&L Pcc 1:3:6 Type C-0 In 12.5 Mm Graded Stone Aggregates Hold Fast Fillinng Inside Frame & Hold Fasts Etc Complete All As Specified 99 S&F Factory Made Flush Shutters 35Mm Thick Ply Construction, Bwp Confirming To Is 2202, Solid Core Construction, With Block Board Core And Plywood Face Panels Commercial Type On Both Sides With 6Mm Thick Lipping Frame To Match Including Supply And Fixing Following Items :(A) Mild Steel Butt Hinges 125Mm - 3 Nos. Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos. Per Leaf(D) Stainless Steel (804 Grade) Finished Sliding Bolt 250 Mm - 1 No. Per Leaf(E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 100 S&F 35Mm Thick Glazed And Skelton Shutters Of 2Nd Class Hard Wood (Factory Made) Open Rebated And Divided To Receive Glass, Gauze Etc (Without Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass Etc Size Of Members Of Shutter As Specified In Ssr-91 Pt-1 Section 8 Clause 8.20(A), Kiln Seasoned And Chemically Pressure Treated All As Specified Including Stainless Steel 304 Grade Wire Cloth (0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm) All As Specified And Including Supply And Fixing Following Items :(A) Stainless Steel (304 Grade) Finished Butt Hinges 125Mm - 3 Nos Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos Per Leaf(D) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16X250Mm - 1 No Per Leaf (E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 101 M&L For Two Coat Of Synthetic Enamel Paint (Finishing Coat) Over One Coat Of Pink Primer To New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Incl Prepration Of Surfaces Complete All As Specified And Directed. 102 S&F 300Mm, Ordinary Rat Tail Rod Pattern Springs Including Roller And Roller Plate Complete All As Specified And Directed. 103 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 104 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X35 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 105 S & F In Replacement Of Surface Mounted Led Bulk Head Luminaire Of Capacity 10 Watt With Abs Body & Polycarbonate Diffuser, Ip54 Inc Connection With ,With Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 106 Supply And Fix Lamp Holder Including Led Bulb 9 W Including Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 107 M & L For Sub Main Wiring With Two Single Core 6.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 6.0 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2(Two) Runs Of 6.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 6.00 Sqmm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note 2 :(I) Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces And Cutting Not Exc. 10 Cm Girth . (Iii) Including Taking Out/Down Existing Unserviceable Sub Main Wiring. 108 S & F In Replacement Of Sheet Metal Enclosure Db Tpn 4 Ways Double Door 415 Volts With 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables Complete With Ip-43 Protection Complete All As Specified And Directed By Engr-In-Charge 109 S & F In Replacement Of Mcb, Triple Pole & Neutral (Tpn) 10 Ka 240 Volts 40 To 63 Amp Capacity Fixing In Db’S Complete All As Specified And Directed. (Note: Mcb Should Be B Or C Curve As Directed By Engineer In Charge) 110 Supply And Fix In Replacement Of Sheet Metal Enclosure 8 Ways Double Door For Dbs When Mcbs Are To Be Used 240,Volts Including 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link All Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables With Ip43 Protection Complete All As Specified & Directed By Engr-In-Charge. 111 S & F In Replacement Of Mcb, Single Pole 240 Volts 6 To 32 Amp Capacity For Fixing In Db’S Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 112 Supply And Fix In Replacement Of Mcb , Spn, 240 Volts ,40-63 Amp For Fixing In Dbs Of Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 113 M & L In Replacement Of Unsv Earthing Complete With Galvanized Iron Earth Plate Electrode Of Size 600X600X6.0Mm , Buried Directly In Ground (Earth Pit Not Less Than 2.25 Mtrs Below Normal Ground Level) With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected To Galvanized Earth Lead Wire 4.0 Mm Dia By Means Of Bolts , Nuts , Check Nuts And Galvanized Iron Or Steel Including Earth Work In Any Type Of Soil, Charcoal Salt 15 Cm Around The Earth Plate 20 Mm Dia Watering Pipe Medium Grade 1.70 Mtr Long With A Plug At Top, Gi Protection Pipe Light Grade 15 Mm Dia From Earth Pit To Main Board Including Pcc Pit In Cement Concrete 1:2:4 Along With Ci Frame And Cover 10Mm Thick Duly Hinged To Ci Frame As Shown In The Electrical Plate No3 Of Ssr 2009 Part 1 Specification At Page 497. 114 Xlpe Insulated ,Screened, Pvc Bedded, Galvanized Steel Wire Armoured, Electric Power Cables (Heavy Duty) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 25 Sq Mm 4 Core Supplied & Laid In Replacement Complete All As Specified& Directed By Engineer-In-Charge. 115 Excavation In Trenches Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5 Mtr In Depth For Laying Of Cables Including Getting Out In Any Kind Of Soil Complete All As Specified And Directed. 116 Returning Filling In Including Spreading, Levelling, And Well Ramming, In Layers Not Exceeding 25 Cm Each Layer Of Any Kind Of Soil. 117 Removing Surplus Excavated Material From Site Not Exceeding 50 Mtrs From Starting Point And Depositing Where Directed At Level Not Exceeding 1.5 Mtr Above The Starting Point. 118 Material And Labour For Sand Cushioning For Cables 8 Cm Below The Cable And 15 Cm Above With Dry River Sand In Trenches For Cushioning Of Underground Cable Line Including Spreading, Leveling, Well Ramming Completed All As Specified And Directed. 119 Cutting Of Hardstanding Floor/Wall For Laying Of Cable Including Matching With Suface By Using Cement Concrete All As Specified And Directed. 120 Supplying & Laying Factory Made Unreinforced Precast Concrete Cable Covers Class Lv Type 1, Flat, Size 250X150X40Mm Laid In Trenches As Protection To Cables Complete All As Directed By Engr-In-Charge 121 Material And Labour For Replacement Of Gi Tubing Light Grade 40 Mm Bore For Passing Through Cables Under The Floor ,Along The Wall Or Along The Pole Complete All As Specified And Directed. 122 Dismantling Of Stone Slab And Tiles Laid Bedded And Pointed In Any Mortar Description Or Thickness In Floors, Apron Etc Complete All As Specified. 123 M & L For Screed Bed Or Bedding Layer Of Mortar 15 Mm Thick In Cm 1:6 For Laying Floor Finishes Complete All As Specified. 124 M&L For Virified Ceramic Light Shade Tiles 8 - 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc,Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Epoxy Cartridge Tile Grout Using Fill The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour. 125 All As Per Item No 124 But As A Skirting Incl. 10Mm Thick Rendering As In Back Coat Complete All As Specified. 126 M&L For 7 To 8 Mm Ant-Skid Ceramic Joint Free Premium Quality Coloured Tiles Area Of Each Tile Esc 0.06 Spm But Next 0.11Sqm, As In Floors Etc. In Any Pattern Ghe & Dark Tiles As Approved, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, In Floors Etc. Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 127 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Laid Over Cement Screed Base 15Mm Thick In Cm 1:6 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 128 Rounding To Edges Of Stone Slabs One Edge, Such As In Steps, Cooking Platform, And Other Similar Situations All As Specified. 129 Dismantling Water Tanks And Removing To Store Of Capacity Exc 500 & Not Exc 1000 Ltrs Complete All As Specified. 130 Supply And And Fixing, Hoisting Pvc Tank Of 1000 Ltr Capacity Including Supplied And Fixed 20Mm Dia Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed.(Minimum Weight 15Mm-142 Gms/20Mm-210Gms/25Mm-455 Gms/40Mm-690 Gms Float Valve Assembly Complete All As Specified And Directed. 131 S&F In Repair Wall Mixture Mixing Valves Incl. Three Joints To Steel Pipes Or Unions 15 Mm Bore Fancy Type Best Quality As Per Sample Approved By Ge Make-Jaquar Cat Part No Qqp-7217Pm Or Equivalent In Hindware/Kohlar. 132 S&F Pvc Cabinet 600X450Mm Overall Size With Looking Mirror Of Selected Qality Glass Mountedover Pvc Framing As Per Sample Complete Fixed In Repair Complete All As Specified. 133 S&F Stainless Steel Plate Rack Of Size Not Less Than 90Cmx75Cm(Wt N. Less Than 4 Kg) Fixed With Stainless Steel Screw Including Taking Out Old Unserviceable Wooden Plate Rack As Approved By Ge Complete All As Specified. 134 S&F In Repairs Chromium Plated Shower Roses With Swivel Joints 125 Mm Dia Size Incl Fixing To Gi Pipe/Union Fixed Make-Jaquar /Hindware/Kohlar. 135 M & L For Rendering 15 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:6 Finished Even And Smooth ( Without Using Extra Cement ) With Sagol Finish On Plastered Surface Complete All As Specified And As Directed. 136 M&L For Preparation Of New Decorated Plastered Or Unplastered Surfaces Of Walls And Applying Two Coats Of Exterior Emulsion Over One Coat Of Primer And Over 2Mm Thick Putty For Levelling And Smoothening, Complete All As Specified And Directed. 137 M&L Preparation Of New Plastered Surface Of Walls And Applying Two Coats Of Oil Bound Distemper Over 1.5Mm Thick Wall Care Putty Complete All As Specified And Directed. 138 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 139 S&F Sinks With Drainage Board Made Of Stainless Steel Lmm Thickkitchen Or Laboratory With Plugs,Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X 460Mm Bowl Size 410Mm X 330Mm X 160Mm Complete All As Specified And Directed. 140 S&F In Repair Brass Chromium Plated Sink Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar /Hindware/Kohlar 141 S&F Powder Coated Anodised Aluminium Frame For Doors, Windows Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified And Directed. 142 S&F Frosted Glass 4.00Mm Thick Ordinary Quality And Glazing With Oil Putty In Square N.Exc 0.50Sqm In Each Panes Complete All As Specified And Directed. 143 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Sketon/Glased Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 144 S&F Factory Made Wpc Extruded Board Cnc Machine Cut Jali Fixed To Skelton Door As Per Approved Design Complete All As Specified And Directed 145 S&F Kitchen Cabinets Including All Fittings And Fixtures Incl The Follwing. (A) 19Mm Thick Plywood Of Commercial Block Board,Make: Kitply/Century Ply/ Green Ply(B) 1Mm Thick Commerical Lamination On Both Side Fixed To Black Board(Colour And Design As Approved)(C) Ss Pullout Basket Ss Finish Of Plain 15 X 20 X 6 (D) D Type Handle 100Mm Ss Finish(E) Pullout Basket Ss Finish Cutlery Wire Of Size 15X20X4 (F) 2Nd Class Hard As In Frame Work(G)Ss Channels For Pullout Basket As Required. (Note:- The Measurement Shall Be Taken From Front Elevation And Not Girthwise. 146 S&F Factory Made Upvc Brown Colour Door Shutter Made Of Extruded Profile With Wall Thickness Of 2.3Mm(+-0.2Mm) Door Profile With Hollow Section With Multy Chamber. Frame (60X62Mm),Sash(42Mmx67Mm).Sliding Interlock(One Verticle Length In Each Shutter)(45.5Mmx28Mm).Glazing Bead(24.5Mmx16Mm)Will Be Mittred Cut And Fusion Welded At All Corner.Including Drilling Holes For Fixing Hardware And Drainge Of Water Etc Am,.Making Arrangement For Fixing Of Hardware.Epdm Gasket,1.2+0.2 Mm Thick Galvanised Steel Frame(30Mmx21.5Mm).Sash (30Mmx18Mm)Profile To Be Inserted In Required Profile.Frame Will Be Finshed To The Wall With 8Mmx100Mm Long Fasteners.Hardware Touch Lockof Zinc Alloyed(Brown Powder Coated)Steel Roller System Including 5Mm Thick Glazing With Selected Quality Glass ,Aluminium Track And Bottom Rail For Two Track Sliding Fram,Wool Pine For Sliding Sash And Interlock. Note.The Unit Rate Coated By Contractor Includes Cost Of Glass And All Other Conncted Accessories,Net Opening Will Be Measured For Purpose.Make:H2O Window,Fenesta,Anuplast As Approved By Ge. 147 M&L For Rcc 1:2:4 Type B-1 Using 20Mm Graded Crushed Stone Aggregate In Any Situation Except Foundation Complete All As Specified And Directed. 148 S&F 10Mm Dia And Above Tmt Bars Cut To Length, Bend To Shape As Required Including Cranking, Hooking Ends & Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Complete All As Specified And Directd. 149 All As Item No 77 Here In Before But 5Mm Dia And Over Upto & Including 10Mm Dia In Stirrups, Spaces & Binder Complete All As Specified And Directd. 150 S & F Powder Coated Aluminium Window/Ventilator Shutters, Side Hung Type With Sash Bars, Including Necessay Joinery Cleats, Glazing Clips, Rubber Packing, Chowkats Aluminium Snap Beading, Screws, Suitable Handle Etc With And Including Sheet Glass Or Ordinary Glazing Quality Of 4Mm Thick And Incl Gi Wire Mesh 0.56 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18 Mm , Size Of Side Rails , Top Rails , Bottom Rail 85X44.5Mm And Size Of Chowkat Frame 101.6X44.45Mm And Thickness Of Aluminium Member Shall Be 1.40Mm Thick Complete All As Specified. 151 S&F For Prelaminated Particle Board 18/19 Mm Interior Grade Prelaminated On One Side With Decorative Choice Lamination And Other Side Balancing White Lamination Fixed With Screw Timber Frame Work Including Dismantling Board All As Specified. 152 S&F In Repair Continuous (Paino) Hinges, Mild Steel, Bright Finish Or Electrogalvanised Width Of Flap (When Open) In 40Mm All As Specified. 153 S&F In Repair 40Mm Dia, Cupboard Knobs Fixed With Nut, Screw And Washer Of Mild Steel Bright Finished All As Specified. 154 S&F Ball Catches With 8Mm Dia Steel Ball And Brass Body And Striking Plate Including Letting In And Fixing Complete All As Specified. 155 Supply & Fix In Replacement Of Modular Bell Push Switch 1 Way, 6 Amps, 1 Module Complete All As Specified. 156 Supply & Fix In Replacement Of Call Bell Ding Dong Ac 230 Volt Single Pole Complete All As Specified. 157 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 300 Mm Sweep 900 Rpm Metal Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Hole Making Louver Complete All As Specified And Directed By Engineer-In-Charge. 158 S & F Modern Energy Efficient Bedroom Muziris Wall Decorative Light Of Capacity 20 Watt Single Headed 240 Volt, Ip20 Rating, Controller Type (Push Button), Product Weight 1.04 Kg, Body Material (Metal), Power Source (Corded Electric),Lamp Base E27, Colour(Bronze) Incl Electrically Connection , Including Removing Of Unserviceable Decorative Light Fittings Of Any Description Complete All As Specified And Directed By Engr-In-Charge. Make: Philips Model No 31425 Or As Equivalent. 159 Excavating In Trenches N Exc 1.50M In Width And N Exc 1.50M In Depth For Foundation, Manholes Etc As Well As N Exc 10 Sqm On Plan Area And Getting Out In Soft/Loose Soil All As Specified And Directed. 160 M&L For Pcc 1:5:10 Type E-2, Using 40Mm Graded Crushed Stone Aggregate In Foundation, Filling And Mass Concrete All As Specified And Directed. 161 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 162 S&F Mild Steel Deformed Bars, 6Mm To 8Mm Dia Cut To Length, Bent To Shape Required Including Cranking And Binding With & Including Mild Steel Wire (Annealed) Not Less Than 0-.90Mm Dia Complete. 163 M&L For Form Work To Soffits Of Suspended Slabs Such As Roof Slabs Etc For Rough Finished Concrete Surface Complete All As Specified And Directed. 164 M&L For Form Work To Sides For Slabs And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10 Cm But N Exc 20 Cm Wide For Fair Finished Concrete Surface Complete All As Specified And Directed. 165 Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams And Similar Work, Vertical Or To Batter For Rough Finished Flat Surfaces Of Concrete. 166 Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions, Square, Rectangular Or Polygonal For Rough Finished Flat Surfaces Of Concrete. 167 M&L For Rendering In Cement Mortar (1:6) 10 Mm Thick Finished Even Smooth Complete All As Specified On Brick Or Concrete Surface Of Fair Faces. 168 M&L 15Mm Thick Cement Plaster In Two Layer First Coat In Cm 1:6,10Cm Thick & Second Layer 5Mm Thick In Cm 1:4 Mixed With Wpc 3% By Weight Of Cement Including Finishing Fair & Even On Brick Or Concrete Surfaces Of Othern Than Fair Faces. 169 M&L For 5Mm Thick Cement Plastering To Rcc Surfaces In Cm :1:3) Finished Even And Smooth W/O Using Extra Cement On Ceiling Surfaces. 170 S&F Stainless Steel Butt Hinges Medium Weight Cold Rolled Isi Marked Of Size 100 Mm Complete All As Specified And Directed. 171 M&L For Ms Framed Guard Bars Conforming To Fe-410-0 Or Fe-310-0 Welded To Steel Windows/Ventilations Complete All As Specified And Directed. 172 S&F Vitrous China Squatting Pan Of Orissa Patterns Long Pan Size 580Mx440Mm White With P Or S Trap Front Of Back Inlet And Foot Rest Including Long Band Any Pattern (Excluding Flushing Cistern And Flush Pipe) Including Provision For Lime Concrete Bedding. 173 S&F Pvc Flushing Cistern Low Level 10 Ltr Cap With Inlet Ball Valve Float And Handle Syphonic Action Type Incl Brackets And Flush Pipe Of Polythene Of Low Or High Density Isi Marked. 174 S & F In Repairs Vitreous China Oval Shape Wash Basin, White, Flat Back, Size 580 X 450 Mm Excluding Taps, Waste, Chain And Plug And Porcelain Stopper But Including Brackets With 32 Mm Dia Waste Fittings, Brass, Chromium Plated With Waste Pipe Complete All As Specified. 175 S&F Looking Mirror Of Selected Quality Mounted On 6 Mm Thick Ply And Fixed To Wall With Wooden Plugs Chromium Plated Brass Screws And Washers. 176 S&F For Ci Floor Trap With Incl Jointing With Waste Pipe In Cement Mortar Of Size 100Mm. 177 S&F Gully Trap Stone Ware Square Of Round Mounted Type P Of Size 150X150Mm. 178 S&F 20Mm Dia Stop Valve Of Copper Alloy Screwed Down High Pressure With Crutch Or Butter Fly Handle Screwed On Both Ends For Iron Pipe Or For Union Fixed. 179 S&F Pvc Connection 15Mm Dia 600Mm Long Of Heavy Grade Screwed One End To Inlet Of Whb/Pillar Tap/Cistern Etc Complete Incl Brass Union Coupling On Both Ends Connfirming To Is-3076 Complete With Connector For Connection Old Water. 180 S& F For Ci Pipe 75Mm Dia Laid In Floor In Any Length With Or Without Cars With Cement Joint (Waste & Vent Pipe). 181 All As Per Item No 38 Here In Before But 100Mm Dia. 182 S&F For Ci Bend Any Radius Disminshing Pieces Or Tyes Of 100Mm Bore With Ducks For Or Head Rest. 183 S&F For Ci Branch Pieces Single Equal Or Unequal Ordinary Or Inverted Or With Paralled Brnach 100 Mm Bore. 184 S&F Cast Iron Sand Cast Pipe 100 Mm Dia With Or Without Cars With Cement Joint Fixed To Walls. 185 S&F Cast Iron 100 Mm Cowl. 186 M&L For Pcc 1:4:8 Type D-2 Using 40Mm Graded Stone Aggregate)75Mm Thick On In Sub Base Of Fllor .. 187 M&L For 15Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And Directd. 188 M&L For Coloured Glazed Ceramic Tiles On Vertical Surface (300Mmx600Mx7M) Thick Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 189 M&L For Coloured Non Skid Ceramic(300X300Mm) Tiles 7 To 8Mm Thick As In Floor Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 190 S&F Steel Ventilation With Top Hung Shutter Including Hinges, Steel Peg Stay Complete. 191 S&F 4Mm Thick Sheet Glass Of Figured,Pin Headed And Glazing With Oil Putty In Square N Exc 0.50 Sqm In Each. 192 M&L For Preparation Of Newly Steel Surfaces And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Over 10 Cm Width Or Girth Complete All As Specified And Directd. 193 M&L For Preparation Of Newly Plastered Surfaces And Applying Two Coats Of Cement Base Paint Over A Coat Of Chalk Whiting Complete All As Specified And Directd. 194 M&L For Three Coats Of White Wash On Wall Of Newly Plastered Surface. 195 S&F For Preparation Of Newly Plastered Surfaces And Applying Three Coats Of White Wash On Ceiling. 196 M & L For Factory Made Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And As Directed. 197 S&F Factory Made Solid Pvc Moulded Door Shutter, With Particle Board Core, 28 To 30Mm Thick (Stiles), With 2, 4, Or 6 Raised Panel Design With 2Mm Thick Moulded Pvc Sheet On The Front Face & 2Mm Plain Colour Pvc Sheet On Back Face & 5Mm Thick Plain Colour Pvc Sheet On Back Face, Supplying & Fixing In Frame At Site As Per Specification & Drawing All As Specified. 198 S&F Aluminium Tower Bolt 150Mm Long Stove Enamelled Black With Bright Bolt & Fixed. 199 S&F Aluminium Sliding Door Bolt With Hasp And Staples Type Bolt Type , 300Mm Long Stove Enamelled And Fixing Clips Of Sheet Cast Or Extruded Section Or Cast Aluminium Alloy And Fixed All As Specified. 200 S&F Aluminium Alloy Handle Of 100M Size Oval Type Stove Enamelled & Fixed All As Specified. 201 M&L For Rendering 10Mm Thick Cm (1:4) On Roof Slab Top, Mixed With Water Proofing Liquid Finished Even And Fair Without Using Extra Cement Complete All As Specified. Note: Water Proofing Liquid Shall Be Measured And Paid Separately. 202 M & L For Cleaning The Newly Plastered Surfaces Of Concrete ( Roof Etc) With Wire Brushes And Applying Water Proofing Treatment As Under :-I) Apply One Coat Of Oil Bound Bituminous Primer @ 0.25 Kg/Sq.M Ii) Providing And Laying 3 Mm Thick App Modified Water Proofing Membrane Weighing Not Less Than 3.5 Kg / Sqm Reinforced With Non Woven Polyester Mat Weighing Not Less Than 160 Gm/Sqm All As Specified Procured From Any One Of The Approved ManufacturerS Iii) Apply One Coat Of Solar Reflective Bituminous Aluminium Paint @ 0.15 Kg/Sqm Over Membrane Over Non Assesble Roof Surfaces Complete All As Per ManufacturerS Instructions And As Directed . 203 M/L Brick Work In Cm1:4, In Half Brick Thick Wall. 204 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 205 S/F Vitreous China Toilet Paper Holder Fixed To Walls With Chromium Plated Cp) Brass Screws 206 S/F Vitreous China Soap Dish Of Appx Size 160*160*90Mm Any Type Fixed To Plugs With Chromium Plated Brass Screws 207 S/F Sheet Glass Shelf Assembly Consistig Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Brackets Guard And Railing 60Cm Long 208 S & F Brass Chromium Plated Tubular Towel Rail, 20 Mm Dia, D Type, 60 Cm Long Between Flanges Complete All As Specified. 209 M & L For Granite 20 Mm Thick Machine Cut, Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Griding And Polishing Types All As Specified. 210 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 211 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 212 S&F Health Faucet Including Ms/Anodised Hanging Device Fixed Complete All As Specified And As Directed. 213 Surface Excavation Not Exceeding 30Cm Deep And Averaging 15Cm Deep And Getting Out In Loose / Soft Soil All As Specified And Directed. 214 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 215 M & L 100Mm Thick Pcc 1: 4: 8 Type D2 (Using 40Mm Graded Stone Aggregate) As In Sub Base Complete All As Specified And Directed. 216 M&L For Machine Pressed Precast Concrete Interlocking Paver Block Rubber Moulded Any Shape And Size Confirming To Is 15658-2006 Of 60Mm Thickness, M-35 Grade With Grey And Pigment As In Floor/Pavement Complete All As Specified And As Directed. 217 M&L For Providing Precast Concrete Type C-1, 1:2:4(Using 20Mm Graded Stone Aggregate) As In Kerb Blocks With Plain Fiar Faces, Including Chamferes, Weathering, Throating Etc And Setting In Mortar 1:4 Complete With Joints To Match. 218 M&L For Cement Concrete Type 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundations, Filling And Mass Concrete Complete All As Specified And As Directed. 219 M & L For Sand Filling Under Floors Or In Foundation Including Watering And Consolidation 220 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X25 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 221 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 222 M&L For Boring Of Holes Under Road, Pavement, Hard Standing By Trench-Less Technology Using Ultrasound Technique And Necessary Machine Suitable To Pass Through 40 To 80 Mm Bore Gi Tubing And Cable Etc Complete All As Specified And Directed.Note: Gi Pipe Shall Be Measured And Paid Seperately Under Relevant Item.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
2.
Rural Development #11465735 Price Bid
Development Works At Shree Skhetra Jagdamba Devi Sanshtan At Sav. Tq. Dist. Buldana.- 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 2 Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means 3 Excavation for foundation in Hard murum including removing the excavated material upto a distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringand struttingetc. complete. (Lift from1.5 to3.0m.) By Mechanical Means 4 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. 5 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 6 Providing and laying in situ /Ready MixCement concreteM-20of trap / granite /quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchionsetc. including bailing out water,Steel centeringformwork, laying/pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 7 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 8 F.F. 9 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 10 F.F. 11 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landingsas per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 12 F.F. 13 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADAenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 14 F.F. 15 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 16 F.F. 17 Providingandapplyingwaterproofingtreatmentusingacrylicpolymermodifiedcement basedwaterproofingcoatingwithfibreglassmeshmixingattherateofpowdertoliquid (2:1)byweightcovering9to10SquareMetre/Kilogramwithtwocoatusingapproved chemicals for masonry andconcrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. FF 18 Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineer inchargein layers of 15 cmto 20 cm including watering and compaction etc. complete. 19 Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. 20 Providing and laying Cast in situ/Ready Mix Cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 21 Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 22 F.F. 23 Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. FF 24 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm . FF 25 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. FF 26 Providing and fixing 30mm thickPVC FLUSH L DOOR SHUTTER consisting of panel of hollow PVC profile of 20 mm thickness consisting frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mminserted inside the hollow section of stiles rails top ?and bottom railsandtwo19x19mm MStubesinsertedhorizontallyinsidethe hollowprofile section using 4/5 mm sheet using screws hollow profile shall be lipped with 10 mm (5mm x2) thickx20mmwidthonstilesandrailsusingsolventcement.Theinnerpanelshallbe laminatedwith5mm thicktermite proofwaterproof plain/prelam PVCsheet using solvent cementonthebothsidesofthepanelincludingstainlesssteelfixturesandfasteningetc. Complete as per direction of Engineer incharge, manufacturers specification and drawing. FF 27 Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. 28 F.F. 29 Providing andfixing inposition(asper1868/1982)Aluminium sliding windowofthree tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeofbearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre.Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm atweight 0.417Kilogram/Runningmetre.Asperdetaileddrawingsandasdirectedby Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainlesssteeljailwithall required screws and nuts etc, complete. With powder coating without box 30 F.F. 31 Providing and fixing in position powder coated aluminium louvered windows / ventilator of varioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete. FF 32 Providing and fixing foldable mild steel door using fully anodised sections of hollow square pipe 40 X 40 X 4 mm & 80 X 40 X 4 mm, M. S. sheet and grill as per drawing with all accessories etc. complete. (I.S. 105211983). [ Item as per Circular No. 1304 Dt. 24/02/23 33 Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, moulding edges, cleaning complete. a) Marble other than white makrana 34 F.F. 35 Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. 36 F.F. 37 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 38 F.F. 39 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. 40 F.F. 41 Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. 42 F.F. 43 Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete 44 F.F. 45 Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortarincludingfloatfilling jointswithneatcement slurry curing polishing and cleaningetc. complete. 46 F.F. 47 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 48 F.F. 49 Providing and applying plastic emulsion paint of approved quality, colour and shade tonew surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. 50 F.F. 51 Providing and applying two coats ofexterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. 52 F.F. 53 Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and1.5mmthickattop, 40mm diameterand1.5mm thickverticalsupportsspacedat1.5m centertocenterand8mmthicktoughenedglassincludingfabricating,fixtures,errecting, necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete 54 Providing and fabricating structural steel work in rolled sections, fixed with connecting plates oranglecleatsinmainandcrossbeams,hipandjackrafters,purlinsconnectingtotruss members andthe like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil paintingofapproved quality and shade etc. complete. 55 Providingandfixingcorrugatedgalvanisedironsheetsof0.63mmthick(24B.W.G.)for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). 56 Providing and fixing board displaying information, such as Name of work, Tender cost, Name of Contractor, Work completion and liability period etc, having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge 57 Royalty Charges for Metal and Murum 58 Royalty Charges for Sand 59 Fineness Modulus,Silt & Clay Content 60 Compressive Strength 61 Water Absorption. Compressive Strength. Efflorances 62 Gradation 63 Standard Consistancy Fineness, Specific Gravity, Setting Time ( Initial & Final), Compressive Strength, Soundness 64 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 65 Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means 66 Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto1.50m)ByMechanical Means 67 Excavation for foundation in Hard murum including removing the excavated material upto a distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringand struttingetc. complete. (Lift from1.5 to3.0m.) By Mechanical Means 68 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. 69 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 70 Providing and laying in situ /Ready MixCement concreteM-20of trap / granite /quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchionsetc. including bailing out water,Steel centeringformwork, laying/pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 71 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 72 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 73 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landingsas per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 74 ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-20oftrap/granite/ quartzite/gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem ifspecialfinishistobeprovidedandcuringcomplete.(Excludingreinforcementand structuralsteel).withfullyautomaticmicroprocessorbasedPLCwithSCADAenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 75 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 76 ProvidingandfixingheavydutyinterlockingconcreteRUBBERMOULDGLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kilogram/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaningetc. complete. (using 100% crushed sand) 77 Providing andlaying Castinsitu/ReadyMixcement concrete M-15oftrap/ granite/quartzite/gneissmetalforcoping to plinthorparapet,mouldedorchamferedasper drawingorasdirectedincludingsteelcentering,plywood/steelformworkcompacting, rougheningthemifspecialfinishistobeprovided,finishingunevenandhoneycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) 78 Providing and fixing board displaying information, such as Name of work, Tender cost, Name of Contractor, Work completion and liability period etc, having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge 79 Royalty Charges for Metal and Murum 80 Royalty Charges for Sand 81 Fineness Modulus,Silt & Clay Content 82 Compressive Strength 83 Standard Consistancy Fineness, Specific Gravity, Setting Time ( Initial & Final), Compressive Strength, Soundness 84 Gradation
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Maharashtra View Result →
3.
Public Administrative Department #11418578 AOC
Tender For To carry out various development and maintenance works in Adarsh ​​School in Ward No. 36-Providing and fixing colour coated Zincalume (R) AZ150 (min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon)coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center tocenter. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) with COLORBOND ( R ) steel quality super durable polyester paint ( SSR Item No : 38.34 ) (PMC Bhavan ) Unique No (15655) Rate List Year (2024-2025) ITEM NO : 2 Providing and fixing partition of welded mesh of 3 mm dia. wires 50 mm x 25 mm size mesh including integrated non teak seasoned wood frame 80 x 50 mm of vertical and horizontal scantling and finishing with oil painting 3 coats etc. complete ( SSR Item No : 39.27 ) (PMC Bhavan ) Unique No (15701) Rate List Year (2024-2025) ITEM NO : 3 Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.Number: As directed by Engineer- in-charge. ( SSR Item No : 23.09 ) (PMC Bhavan ) Unique No (15305) Rate List Year (2024-2025) ITEM NO : 4 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. ( SSR Item No : 23.01 ) (PMC Bhavan ) Unique No (15297) Rate List Year (2024-2025) ITEM NO : 5 Oil paint glass finish : Providing and applying two coats of oil paint glass finish bituminious paint of approved colour to new structural steel work and iron work in buildings including scaffolding if necessary, cleaning and preparing the surface etc. complete ( SSR Item No : 63.2 ) (PMC Bhavan ) Unique No (16692) Rate List Year (2024-2025) ITEM NO : 6 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. ( SSR Item No : 26.33 ) (PMC Bhavan ) Unique No (15352) Rate List Year (2024-2025) ITEM NO : 7 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. ( SSR Item No : 27.01 ) (PMC Bhavan ) Unique No (15370) Rate List Year (2024-2025) ITEM NO : 8 Providing internal cement plaster 20mm. thick in Single coats cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. ( SSR Item No : 32.08 ) (PMC Bhavan ) Unique No (15443) Rate List Year (2024-2025) ITEM NO : 9 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. SSR Item No : 32.11 ) (PMC Bhavan ) Unique No (15444) Rate List Year (2024-2025) ITEM NO : 10 Providing and laying matt finish ceramic tiles of having size 30 cm 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. SSR Item No : 33.24 ) (PMC Bhavan ) Unique No (15492) Rate List Year (2024-2025) ITEM NO : 11 Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. SSR Item No : 33.25 ) (PMC Bhavan ) Unique No (15493) Rate List Year (2024-2025) ITEM NO : 12 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track sect ion 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. SSR Item No : 39.37 ) (PMC Bhavan ) Unique No (15711) Rate List Year (2024-2025) ITEM NO : 13 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item Number 15 to 18 prior approval of Superintending Engineer will be necessary ( SSR Item No : 35.26 ) (PMC Bhavan ) Unique No (15576) Rate List Year (2024-2025) ITEM NO : 14 Wall Painting art work : painting artistic work on any type of surface and at any height using scaffolding with skilled artists as per the instructions of site incharge.measurement will be as per actual max.size of art.rate for background apex paint and lettring will be paid seperately ( SSR Item No : 63.4 ) (PMC Bhavan ) Unique No (16694) Rate List Year (2024-2025) ITEM NO : 15 painting various letters /sentences in any languages on any surface using weather shield paint from skilled painter upto 10feet ht.from existing grond level.for measurements minimum height of letter will be considered.background paint if required will be paid seperately ( SSR Item No : 63.5 ) (PMC Bhavan ) Unique No (16695) Rate List Year (2024-2025) ITEM NO : 16 Providing and fixing 12 mm thick waterproof plywood ( durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI) ) ( SSR Item No : 62.11 ) (PMC Bhavan ) Unique No (16542) Rate List Year (2024-2025) ITEM NO : 17 Providing and fixing 19 mm thick waterproof plywood ( durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI) ) ( SSR Item No : 62.12 ) (PMC Bhavan ) Unique No (16543) Rate List Year (2024-2025) ITEM NO : 18 Laminates sheets 1 mm thick : Providing and fixing laminates sheets as per company specification and fix it with fevicol – Recommended companies- formica, Royal touch, Marino , Green lam , Euro. ( 1 mm thick laminates sheets ) ( SSR Item No : 62.23 ) (PMC Bhavan ) Unique No (16566) Rate List Year (2024-2025) ITEM NO : 19 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. SSR Item No : 41.40 ) (PMC Bhavan ) Unique No (15815) Rate List Year (2024-2025) ITEM NO : 20 Providing & fixing 1/2”,1/4”to 1” tk Teakwood leaping patti including polishing etc completed. SSR Item No : 62.27 ) (PMC Bhavan ) Unique No (16570) Rate List Year (2024-2025) ITEM NO : 21 Providing & fixing 3” 5” size Aluminum Brackets/Runners as per site in charge instructions etc. completed.(Including all necessaryFittings) SSR Item No : 62.28 ) (PMC Bhavan ) Unique No (16571) Rate List Year (2024-2025) ITEM NO : 22 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) Hinges SSR Item No : 62.29-A ) (PMC Bhavan ) Unique No (16572) Rate List Year (2024-2025) ITEM NO : 23 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) . Handles SSR Item No : 62.29-B ) (PMC Bhavan ) Unique No (16573) Rate List Year (2024-2025) ITEM NO : 24 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) . Locks (For cupboards & wardrobes) SSR Item No : 62.29-C ) (PMC Bhavan ) Unique No (16574) Rate List Year (2024-2025) ITEM NO : 25 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) . Rubber roller (Heavy Duty) SSR Item No : 62.29-D ) (PMC Bhavan ) Unique No (16575) Rate List Year (2024-2025) ITEM NO : 26 Curtains Providing clothes for curtain of Bombay Dyeing/Binni/Mafatlal etc brands, stitching as per required size with Frill (Zaller) & fixing at required places ( including rings ) Note:-Measurement would be taken as per actual length of window& default width ( i.e . 48” panha). Curtain (Material Synthetic Clothes & cost of clothes starting from Rmt Rs 250/- onwards) SSR Item No : 62.30-B ) (PMC Bhavan ) Unique No (16577) Rate List Year (2024-2025) ITEM NO : 27 Stainless Steel Pipe curtain rod . Providing & fixing of SS pipe curtain rods including Brackets as per site in charge instructions & all necessary Fittings etc. completed SSR Item No : 62.31-A ) (PMC Bhavan ) Unique No (16578) Rate List Year (2024-2025) ITEM NO : 28 Providing and fixing coloured glazed earthenware lipped flat back/corner type urinal with PVC 5 liters flushing cistern with fittings,capacity with fittings, inlet pipe and stop tap, brackets for fixing the cistern, P.V.C. flush pipe with fittings including lead soil pipe, lead trap and soil pipe connection up to the outside face of the wall. SSR Item No : 41.61 ) (PMC Bhavan ) Unique No (15836) Rate List Year (2024-2025) ITEM NO : 29 Providing and fixing Orissa type white glazed earthenware water closet pan of size 260mm x 440mm x 580mm with approved make Slim wall hung cistern with installation kit including S or P trap with cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc.complete. SSR Item No : 48.42 ) (PMC Bhavan ) Unique No (16111) Rate List Year (2024-2025) ITEM NO : 30 PVC Carpet Providing 1.5 mm thick pvc carpet of approved design n color & fixing at site as per site in charge instructions etc. completed.Note: - Dimensions would be considered as per actual carpet size fixed at site. SSR Item No : 62.33 ) (PMC Bhavan ) Unique No (16581) Rate List Year (2024-2025) ITEM NO : 31 Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. SSR Item No : 35.23 ) (PMC Bhavan ) Unique No (15573) Rate List Year (2024-2025) ITEM NO : 32 Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. SSR Item No : 35.12 ) (PMC Bhavan ) Unique No (15563) Rate List Year (2024-2025) ITEM NO : 33 Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. SSR Item No : 36.11 ) (PMC Bhavan ) Unique No (15587) Rate List Year (2024-2025) ITEM NO : 34 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete SSR Item No : 46.19 ) (PMC Bhavan ) Unique No (16026) Rate List Year (2024-2025)
Contract Date: Feb 28, 2026 Contract Value : 20.86 Lakh
Local Bodies No of Bidders 6
Maharashtra View Result →
4.
Public Administrative Department #11417771 Price Bid
Providing Civil Works In Ward No.14 Kalbhor Nagar, Moannagar And Other Areas (Year 2025-26)-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for thefoundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge. Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, f oundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No.: Bd.F.17, Page No. 306 Ground Floor Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means Removing and Transporting of excavated / demolished material within PCMC limit including loading, unloading, stacking the material as directed by Engineer-in-charge etc. complete. (For Lead 10.0 Km). Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with WITHOUT SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:2:4 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:2:4 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer without SCADA with fine agreegates of required specifications (Crushed sand VSI grade ) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material Granular Sub Base Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material (Note- As per circular issued by Hon. city engineer PCMC , vide civil/CE/TS/23/16/2023.Date 21/04/2023 .Rate is reducedby 20% as material brought from PCMCs C and waste processing plant.) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material Note- As per circular issued by Hon. City Engineer, PCMC vide circular no.Civil/CE/TS/23/16/2023 Dated 21/04/2023, rate is reduced to 20% as material is to be brought from C and D work processing plant Supplying hard murum/ kankar at the road site, including conveying and stacking complete. Spreading hard murum/ soft murrum/ gravel or kankar for side width complete Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. Ground Floor Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel st anchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Lift 0.0 to 3.8 M Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. PARDI of required thickness including centering, formwork, cover blocks, laying/pumping ,compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With Crushed sand VSI Grade. Spec. no.:- Bd.F.11 Page No. 304 and B.7, Page No. 38 Ground Floor Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Lift 0.0 to 3.8 M Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. Removing the tar or coba and disposing of the material as directed etc. complete. Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering to 10 Square Metre Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor Lift 0.0 to 3.8 M Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Providing and applying two coats (exterior quality) of flat oil paint of approved colour and shade to the plastered surface in buildings and workshops including scaffolding if necessary, cleaning the surface and preparing surface etc. complete. (excluding primer coat) Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Ground Floor Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. Ground Floor Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 etc
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 8
Maharashtra View Result →
5.
Defence #11392755 Technical Bid
Tender for Material And Labour For Plain Cement Concrete 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundation ,Filling And Mass Concrete Complete All As Specified And Directed . , Material And Labour For Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate) As In Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs Not Provided For, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Etc , Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:3:6 Type C-1 Using (20Mm Graded Stone Aggregate) As In Bed Blocks For Hold Fast,Coping Errection Of Posts Etc Complete All As Specified And Directed. , Material And Labour Reinforced Cement Concrete Nominal Mix (1:1.5:3) Type A1 (Using 20Mm Graded Stone Aggregate) On Slabs Supported On Walls , Beams And Columns In Floors , Roofs,Landings,Balconies, Canopies Deck Slabs, And In Shelves And The Like Complete All As Specified And As Directed. , Material And Labour Reinforced Cement Concrete Nominal Mix (1:1.5:3) Type A1 (Using 20Mm Graded Stone Aggregate) Chajja, Facia Etc And The Like Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:3:6 Type C0 (Using 12.5Mm Graded Stone Aggregate) As In Filling The Hollow Portion Of Steel Frame Complete All As Specified And Directed. , Supply Only Water Proofing Compound. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:4 Complete All As Specifed And Directed. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc To Any Radius In Half Brick Thick Walls Built In Built In Cm 1:4 Complete All As Specifed And Directed , Material And Labour For Form Work On Flat Sides To Soffits Of Suspended Roof Slabs Not Exc 200 Mm Thick (Horizontal Or Sloping), Walls , Beams And Columns In Floors,Landings,Balconies, Canopies Deck Slabs, And In Shelves Rough Finished Surface Of Concrete All As Specified And As Directed. , Material And Labour For Form Work On Flat Sides To Chajja, Fins, Louvers, Fascia Etc Rough Finished Surface Of Concrete All As Specified And As Directed. , Refixing Wooden Or Aluminium Door Shutters Of Any Description Exceeding 1 Sqm But Not Exceeding 2 Sqm Each In The Same Opening After Taking Down, Easing And Adjusting Including Refixing Builders Hardware, Glass Etc As Required And Renewal Of Unserviceable Screws Concrete All As Specified And As Directed. , Supply And Fix For 2Nd Class Hardwood Plain, Solid, Straight Chowkhats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue, Pinned At Joints Complete All As Specified And Directed. , Supply And Fix Factory Made 30 Mm Thick Flush Shutter Solid Core Construction With Block Board Core & Plywood Face Panels Commercial Type On Both Sides Incl 5Mm Thick Teakwood Leaping Alround Complete All As Specified And Directed. , Supply And Fix 2Nd Class Hardwood Factory Made Door, 35 Mm Thick, Glazed And Skeleton Shutters, Open Rebated And Prepated To Receive Glass Gauze Etc (With Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Materials And Revated Sash Bars Any Number , Edges Of Framing Plain Chemfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass In Door Etc Or Provided With Styles And Rails As Specified In Ssr Part 1 Section 8, Clause 8.20 (A) Complete All As Specified And Directed. , Supply And Fix 2Nd Class Hardwood Glazed And Skeleton Window Shutter 30Mm Thick, Divided Into Squares, With Plain, Chamfered Or Rounded, Mitred And Rebated Sash Bars, Any Numbers, To Receive Glass, Gauze, Etc Or Provided With Styles And Rails As Specified In Ssr Part 1 Section 8, Clause 8.20 (B) Complete All As Specified And Directed. , Supply And Fix Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Factory Made Solid Panel Pvc Door Shutter 30Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Heaving A Pvc Sheet Strip Of 20Mm Width Suck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded/ Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Supplying & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Stapple Etc Concrete All As Specified And As Directed. , Supply And Fix 300Mm Long Aluminium Alloy Anodised , Plate Type ,Stove Enameled Black , With Bright Bolt Not Less Than 12Mm Dia With And Incl Minimum Of 6 Bolts And Nuts ,Four On Bolt Plate And Two On Staple Concrete All As Specified And As Directed. , Supply And Fix Stainless Steel Butt Hinges Cold Rolled Meium Weight Of Size 100Mm Etc Complete All As Specified And Directed. , Supply And Fix Stainless Steel Butt Hinges Cold Rolled Meium Weight Of Size 75Mm Etc Complete All As Specified And Directed. , Supply And Fix Aluminium Alloy Handles 150 Mm Long Fabricated Type Complete All As Specified And Directed. , Supply And Fix Aluminium Alloy Handles 100 Mm Long Fabricated Type Complete All As Specified And Directed. , Supply And Fix Aluminium Anodised Barrel Tower Bolts Of Extruded Section 200 Mm Long Complete All As Specified And Directed. , Supply And Fix Aluminium Anodised Barrel Tower Bolts Of Extruded Section 150 Mm Long Complete All As Specified And Directed. , Supply And Fix 300Mm Long Aluminium Alloy Anodised Sliding Door Bolts , With Hasp Staple (Bolt Type) And Fixing Clips Of Sheet Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast-Aluminium Ally Complete All As Specified And Directed. , Supply And Fix Powder Coated Three Track Aluminium Sliding Window With Approved Make Of Following Extruded Section Of Anodised Glazed Shutter As Per Standard Engineering Practices Including All Other Accessories Complete Including 4.00 Mm Thick Tinted Glass Panes, Rubber Beading, Mosquito Proofing, Locking System Etc. Complete All As Specified And As Directed. (Refer Jindal Cat M-2014 ) Aluminium Sections : A Series (I) Shutter Bottom & Top :- 37.50 X 15 X 1.3 Mm Thick (20690) (Ii) Shutter Interlock :- 37.50 X 23 X 1.3 Mm Thick (20689) (Iii) Shutter Side (Handle) :- 37.50 X 23 X 1.3 Mm Thick (20689) (Iv) Frame Bottom :- 75 X 26 X 1 Mm Thick (20671) (V) Frame Top And Sides :- 75 X 26 X 1 Mm Thick (20672) , Supply And Fix Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) Or Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/Neoprene Gasket Required (Fittings Shall Be Paid For Separately) With Extruded Built Up Standard Tubular Material And Labour Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.P. Brass/ Stainless Steel Screws All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge , Material And Labour For Structural Steel Work With Rolled Mild Steel Sections As In Main And Cross Beams, Hip And Jack Rafters, Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Conforming To Fe-290 (Gde E-165) Quality A Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 125Mmx60mmx1.25Mm With Double Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc.Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 105Mmx60mmx1.25Mm With Single Rebate Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc.,Complete All As Specified And Directed. , Material And Labour For Mild Steel Conforming To Fe 410-0 Or Fe 310-0 In Framed Work Such As Grills, Gratings, Etc With Ends Of Bars Shouldered And/Or Riveted Or Forged Into Spikes; Framed Guard Bars; Ladders; Railings And Similar Work Complete All As Specified And Directed. , Supply And Fix Box Type Steel Windows With Side Hung Shutters Both Mosquito Proof And Glazed Shutter Including Projecting Type Hinges With Steel Handle And Steel Peg Stay With Glazing Bars And 12 Mm Square Bar Or Ground Bar Of Approved Design Welded To Steel Window Frame Dovetailed Or Welded Complete All As Specified And As Directed. , Supply And Fix Steel Ventilators With Top Hung Shutter Including Hinges, Steel Peg Stay, Complete All As Specified And As Directed. , Material And Labour For Mild Steel Tmt Bars 10 Mm Dia And Over Cut To Length, Bent To Shape As Required Including Cranking, Bending And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia As In Reinforcement Bar Complete All As Specified And As Directed. , Repairing Of Existing Mild Steel Rolling Shutter Of Any Description Or Any Size Including Replacement Of Damaged Mild Steel Laths, Repairing/ Replacement Of Side Guide Channels, Pipe Shaft, Springs, Ball Bearings, Locking Arrangements, Welding Work, Alingment And Smooth Operation, Including Necessary Nuts, Bolts, Oiling And Greasing, Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Atmospheric Classification Category 3,Four (4) Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified And As Directed , Material And Labour For Pre- Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Plain Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Pattern Corresponding To Is 15965 : 2012 Of Durability Class 3, Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Having Yield Strength Of 550 Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified Complete All As Specified And As Directed. Note: To Be Executed For Provision Of Ridges And Hips. , Material And Labour For 12 Mm Thick Prelaminated Particle Board Bwp Type Melamine Finished (Both Side) For Fixing The Panel Of The Partition/Door Including Necessary Fittings, Gusket, Angle Cleats, Screw Etc Complete All As Specified And Directed. , Supply And Fix Suspended False Ceiling Using E-Grid 2430, 180 Gsm (Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600 Mm With Main Runner 32 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 4Mm Thick High Pressure Stean Crude Everest Non Asbestos Fiber Cement Plain Board (E-Board Classic) In & Including A Grid Of Gi System Duly Suspended With 4Mm Dia Gi Wire Hanger Fixed With Steel Dash Fasteners Or Iron Purlin From The Roof With Adjustment Clip Providing Positions For Light Fixtures,Air Conditioning Diffuser And Ducts ,Sprinkler ,Smoke Detectors Etc.The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C/C. The Last Hanger At The End Of Each Main Runner Should Not Be Placed At More Than 450Mm From The Adjucent Wall,Flush Fitting 1220 Mm Cross Tee To Be Interlocked Between Main Runners @ 610Mm C/C,So As To Form 600Mm X 600 Mm Grid Complete All As Specified And Directed. , Material And Labour For Heavy Duty Parking Tiles Size 300Mm X 300 Mm X 10 Mm Thick White Cement And Pigments Of Approved Maked Jointed With Cement Slurry And Pointed With White Cement Mixed With Pigment To Match With The Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:4) Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm Thick, In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8Mm Thick Area Of Each Tile Exceeding 0.18 And N.Exc 0.38 Sqm In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Exc 0.18 And N.Exc 0.38 Sqm , In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Including 10Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. , Material And Labour For Coloured/ Printed Glazed Ceramic Tiles 7Mm Thick Not Exc 0.15 Sqm In Area In Vertical Surfaces I.E. Dado, Skirting, Etc., Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Tiles, Laid Over And Including Screed Or Screed Bed 10Mm Thick In Cement Mortar 1:4, Complete All As Specified And As Directed. , Material And Labour For 75Mm Thick Cement Concrete 1:3:6 Type C-2 (Using 40Mm Graded Stone Aggregate ) As In Plinth Protection Complete All As Specified And Directed. , Material And Labour For 100Mm Thick Cement Concrete 1:2:4 Type B-2 (Using 40Mm Graded Stone Aggregate) As In Flooring, Hardstanding Complete All As Specified And Directed. , Material And Labour For 100 Mm Thick Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate) In Foundation, Floor Etc Complete All As Specified And Directed. , Material And Labour For 25 Mm Thick Plain Cement Concrete (1:2:4) Type B0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Floor Finished Rough To Receive Tiles Complete All As Specified And As Directed. , Material And Labour For 10Mm Thick Rendering On Other Than Fair Faces Of Brick Wall In Cm 1:6 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement With Using Wpc @3% By The Wt Of Cement. Wpc Shall Be Measured And Paid Seperately. , Material And Labour For 5Mm Thick Rendering On Fair Faces Of Brick Or Concrete Surface In Cm 1:3 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement Complete All As Specified And Directed. , Material And Labour For Preparation Of Newly Plastered Surface Of Wall And Applying A Coat Of Alkali Primer And Two Coats Of Acrylic Distemper Complete All As Specified And Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coat Of Acrylic Exterior Weather Coat Paint (Weather Proof Paint With Quality Of Dust Guard, Anti Algal And Anti Fungal Paint With Minimum 05 Years Performance Warranty, Over A Coat Of Approved Primer Over 1Mm Thick Water Proof Putty Of Same Manufacturer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Wall Surface And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Ceiling Surface And Applying Three Coats Of White Wash Complete All As Specified And Directed. , Material And Labour For 4Mm Thick Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square N-Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For 4Mm Thick Sheet Glass Figured Glass, Pin Head Type And Glazing With Oil Putty In Square N-Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For Preparation And Applying Two Coats Of Synthetic Enamel Paint On New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Over A Coat Of Pink Primer Complete All As Specified And Directed. , Material And Labour For Preparation Of Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide On New Steel Surfaces , Over 10 Cm In Width Or Grith Not Other Wise Described Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 15Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 20 Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Hand Basin White, Flat Back Of Size 550Mmx400mm Fixed On And Including Cast Iron Cantilever Bracket, 32Mm Dia Pvc Waste Coupling And 32 Mm Dia Pvc Waste Pipe Including Fixing Of Tap, Waste Fitting Etc Complete All As Specified And Directed. , Supply And Fix In Repair Bib Taps With Wall Flange 15Mm Bore, Fancy Type, Quarter/Half Turn, Brass Chromium Plated, Long Body With Capstan Head And Cup Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Including Accessories Complete All As Specified And Directed. , Supply And Fix In Repair 125 Mm Dia, Chromium Plated Swivel Type Shower Rose With 195 Mm Long Chromium Plated Shower Arm And Wall Flange Suitable For Fixing 15Mm Bore Iron Pipe All As Specified And Directed , Supply And Fix In Repair Bath Wall Mixer With 15Mm Bore (Dia) Spout, Chromium Plated With Long Bend Pipe For Over Head Shower Including Flanges Complete All As Specified And As Directed. , Supply And Fix In Repair Pillar Taps, Cast Copper Alloy, With Capstan Heads, Fancy Type, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered ‘Hot Or ‘Cold With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe 15 Mm Bore Complete All As Specified And Directed. , Supply And Fix In Repair Cp Stop Valve/Angle Valve 15 Mm Bore, Fancy Type Cromimum Plated With Long Shank And Cup (Concealed Type), High Pressure Crutch Or Butter Fly Handle Screwed Both Ends Screwed For Iron Pipe Or For Unions Complete All As Specified And Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 1000 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places With Fittings And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 500 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places Complete And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix Ball Valves 20Mm Bore Dia Of Pipe High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed (Minimum Weight 20Mm-210Gms). , Supply And Fix In Repair 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers , Supply And Fix In Repair Pvc Valve, Symphonic Action Type, Flushing Cistern 10 Liters Capacity Low Level White With Inlet ,Ball Valve ,Float And Handle Including Brocket Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Pvc (Swr) Pipes, Presure Rate Having 6 Kgf Single Socketed In Any Length With Rubber Ring Joints And Laid In Trenches As In Waste/Soil Pipe Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Complete All As Specified And As Directed. , Supply And Fix 75Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Or Floor Complete All As Specified And As Directed. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 75 Mm Bore Complete. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 110 Mm Bore Complete. , Supply And Fix, In Repair Vitreous China Wash Down Water Closet Of Orissa Pattern Size 580 X 440 Mm White With Integral Foot Rests Including Removing Filled Lean Concrete From Sunken Portion And Putting Of Lean Concrete After Treatment Of Sunken Slab, Connection To Trap And To Flushing Pipe Etc Complete And Making Good To Floor Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Down Water Closed Pan (Pedestal Pattern) With P Or S Trap White, Including Connection To Trap And Cistern, Flush Pipe Including White Plastic Water Closet Seat Cover, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Making Good Disturbed Surface Of Floor Complete All As Specified And Directed. , Supply And Fix In Repair Plastic Water Closet Seat Cover, White, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Fixed Wc Pan Complete All As Specified And Directed. , Dismantling Plain Or Corrugated Steel Sheeting Any Gauge Thickness Including Nanital Or Similar Pattern Roof Covering , Taking Up Or Down 20 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Down Door Chowkhat With Shutter Area N-Exc 1.5 Sqm Each(Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Taking Down Chowkhats Or Frames With Shutters Exc 1.5 Sqm But Not Exc 4 Sqm Each (Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Taking Down Shutters Of Wooden Or Aluminium Door Of Any Description N. Exc 1 Sqm Each Complete All As Specified And Directed. , Taking Down Shutters Of Wooden Or Aluminium Door Any Description Area Exc 1 Sqm And N Exc 2 Sqm Each Complete All As Specified And Directed. , Dismantling Wall And Ceiling Boards Or Insulation Boards, Any Thickness, Any Description, Including Cover Fillets Complete All As Specified And Directed. , Demolition Of Reinforced Cement Concrete (Reinforcement Cut As Required To Facilitate Demolition) Of Any Description And In Any Position Not Otherwise Specifically Provided For Complete All As Specified And As Directed. , Taking Down Cement Plaster Of Any Description On Brick Or Stone Walls Etc Including Racking Out Joints Hacking For Key Scrubbing Down With Water Etc Complete All As Specified And Directed. , Demolition Of Brick Work Built In Cement Mortar Or Cement Lime Mortar , Dismantling Structural Steel Work Including Doors, Gates But Excluding Framed Trusses Etc Complete All As Specified. , Demolition Of Stone Slabs And Tiles Laid Dry And Dry Or Pointed Of Any Description Or Thickness Infloors, Aprons Etc. , Dismantling, Floor Hearth Or Wall Tiling Inclduing Cement Mortar Bedding And Removing Rubbish Off The Premises Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exc. 15 Cm Thickness (Below Or Above Ground Level) Complete All As Specified And Directed. , Demolition And Breaking Up Drain Waste Pipes (Sgsw, Ac Or Rcc, Ci ) Of Internal Dia 75/110 Mm, Set In Cement Mortar In Any Position Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 1.57 Crore
Local Bodies No of Bidders 1
Contract Date: May 10, 2026 Contract Value : 10.71 Crore
Government Departments No of Bidders 2
Uttar Pradesh View Result →
Contract Date: May 10, 2026 Contract Value : 9.80 Crore
Government Departments No of Bidders 2
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 16.49 Lakh
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : 2.96 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 11
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
12.
Rural Development #11324361 Price Bid
Tender For Constructing Anganwadi Building At Karunj Tal.Maval - Part - AExcavationforfoundationinearth,soilofalltypes,sand,gravelandsoftmurum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthe buildingareaand stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 2 Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterial upto distanceof50metresbeyondthebuildingareaandstackingandspreadingas directed,dewatering, preparing the bed for the foundation and necessary back filling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto 1.50m)ByMechanical Means 3 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 4 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (Non SCADA Item) 5 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Concrete Non Scada) 6 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 7 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 8 Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade)(Concrete Non Scada) 9 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 10 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete 11 Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.Layers including watering and compacting etc. complete. 12 Filling in plinth and floors with contractorsmaterial/brought from outside and approved byEngineer inchargein layers of 15 cmto 20 cm including watering andcompactionetc. complete. 13 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 14 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diaMetre / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc complete 15 Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete 16 Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. 17 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 18 Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. 19 Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. 20 Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. 21 Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 22 Providing and preparing kitchen otta up to 75 cm width,made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m. c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. 23 Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. 24 Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete 25 Providing and fixing green marble of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete. 26 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium platedfixturesandfastenings,withbrassmortiselock,chromiumplated handlesonboth sides, and finishing with French Polish etc. complete. 27 Providing andfixing inposition(asper1868/1982)Aluminium sliding windowof three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeof bearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre. Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Running metre. andhandleandtopsection40x18x1.25mm atweight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fittedin vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainless steeljailwithall required screws and nuts etc, complete. With powder coating without box 28 Providing and fixing in position powder coated aluminium louvered windows / ventilator ofvarious sizes with powder coating as per detailed drawing and specifications including aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheet glasslouvers,of approved quality etc. complete. 29 Providing and fixing cold rolled steel hollow door frame 105mm x 60mm for anysizesincludinghold fast hinges,tiememberswith red oxide and gray paintetc. completeas perI.S.I. specifications and code of practice prescribed including anticorrosivetreatmentas directed by the engineer. 30 Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metreasperdrawingincludingfixturesnecessaryweldingandpaintingwith onecoatof anticorrosive paint and two coats of oil painting complete. 31 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 32 ProvidingandfixingwhiteglazedearthenwareWashHandBasinof55cm.x40 cm. sizeincludingcoldwaterpillartap/coldandhotwaterpillartapbrackets,rubber plugsandbrasschain,stoptapandnecessary pipeconnectionsincludingP.V.C.waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testingetc. complete. 33 Providing and constructing Brick MasonryInspection Chamber 60cm x 45cm x 90cmincluding 1:4:8 cement concrete foundation 1:2:4 cement concrete channels halfround G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. 34 Providingsoakpitofsize 120cm x120cm x120cmincluding excavatingandfilling with brick-bats. 35 Providing, laying andfixing P.V.C. pipe of 110mm. dia. withfittingssuch as bends, tees,reducers,clamps,etc.includingnecessary excavation,trenchfillingetc.complete. Including removingexistingpipelineifnecessaryandconveyingandstackingthe sameinPWD chowky or as directed etc. complete. 36 ProvidingandfixingOrissatypewhiteglazedearthenware575mmwatercloset pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside faceofthewall1:2:4brickbatlimeconcretebeddingwithoutflushingtankanditsaccessories etc. complete. 37 ProvidingandfixingH.D.Pcontaineronepiecemouldedwatertankmadeoutofhigh density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tankscapacity between 200 to 1000 liters 38 Providingandfixingonwalls/ceiling/floor15mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete. 39 Providingandfixingonwalls/ceiling/floor25mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 40 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. 41 Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaningoil,grease,dirtandotherforeignmatterandsandpaperingasrequiredetc.complete. 42 Providing and applying two coats of exteriorweather shield paint of approved manufactureand of approved colour to the plastered surfaces including cleaning,preparing the plastersurface,applyingprimercoat,scaffoldingifnecessary,and watering the surface for two days etccomplete. NOTE: ForItem One Number 15 to 18 prior approval of Superintending Engineer will be necessary 43 Providing and applying washable oil-bound distemper of approvedcolour andshade to oldand new surfacesintwocoatsincludingscaffolding,preparingthesurfaces.(excluding the primer coat.) etc. complete. 44 Providing and fixing board displaying information, such as Name of work, Tender cost,Name of Contractor, Work completion and liability period etc, having rectangular shapeof 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted withone coat of Zinc chromate stoving primer and two coats of enamel paint on front side andgrey stove enamel on back side and border / messages / symbols etc. with approved colourshade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly crossbraced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angleiron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black andwhite bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling,transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge 45 Part - BMORTOR. 1)Compressive Strength.( Set of 3 Cubes) 46 STEEL BAR TESTING.2)Above 16 mm (Set of 3 Bars)(Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter,Bend / Rebend Test, Proof Stress.) 47 Royalty For Natural Sand - Screened (for plaster work only) 48 Royalty For Soft Murum
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
13.
Youth Affairs and Sports and Culture #11323145 Technical Bid
Tender For Purchase Of Biomechanical Equipments , Nord Board , It Should Be Portable And Should Have 2 Load Cell Sensors Per Unit With Easy To Attach Hooks Pivoting 360 Degrees Joint Improving Sensor Accuracy It Should Have Knee Position Indicator For Replication Of Test Position In Each Time. Should Have Sample Rate Per Sensor: Upto 400Hz, Capacity Per Sensor: 100 Kg/980-1000N Safe Over Load Per Sensor: 150Kg/1500N, Max Over Load Per Sensor: 200Kg/ 2000N, Resolution: 1N And Sensitivity: 22.0+/-Mv/V. Should Have Rechargeable Battery & Battery Life Should Be100 Active Hours Approx. Should Have Working Temperature Range 5-40®C. (All Weather Proof) Latest Upgradable Software Should Have Both Wired & Wireless Connectivity Connectivity Through Usb (Wired) Bluetooth Low Energy (Ble) For Ipad & Iphone I.E. (Wireless Connectivity) Should Provide 4 Years Warranty On Hardware, Should Be Provided With Latest Upgradable Software And Free Software Updates. Should Have Software Available In Mobile & Laptop (Desktop) Application With Cloud Analytics Platform Applications. Should Have Ability To Collect Data Both Local I.E. Laptop And On Ios Devices. Local Software:- For Data Collection & Data Analysis Locally. Cloud Software:- For Athlete Data Management And Analysis. Local (Desktop /Laptop) Software Should Be Compatible With Windows 10 Desktop Application Ios 13 Or Later Application (Ipad & Iphone). Should Have Ability To Collect Data Of Over 10000 Athletes Or More To Choose With Simple Name Search / Grouping Them. Cloud Analytics Platform For Analysis. Software (Application) Must Give Real Time Feedback Of Testing. License Must Be Valid For 4Years. Cloud Software: - Should Automatically Sync All Data Collected On Local Mobile And Laptop Application When Connected To Internet. O Should Have A Dashboard To See Overview Of Organizations Athletes Data And Different Tiles (Data Indicators) To See Athletes Within And Outside Threshold Zones. Report Section:- Should Have Port Section To Able To Compare Different Groups/Athletes On Longitudinal Data. Should Have Ability To Compare Same Athletes Data Over The Period. Athletes Profile:- Should Have Functionality To Enter Anthropometry (I.E. Upper Body & Lower Body Measurement). Athletes Profile Should Be Auto Sync To Local Application And Flexibility To Move Across Different Groups Or Teams With In Organization And Functionality To Pick Any Athlete From Large Pool (1000 Or More Athlete). • Should Be Able To Setup Different Access To Different People I.E. To Physiotherapist, Sports Scientist And S&C Trainer Within The Organization To Secure Data Access. Api Integration:- Should Have Open-Source Api Code For Integration Into Athlete Management System To Integrate In Ams System. Should Have Software License Valid For 4Years. Wi-Fi Tablet 64Gb, Space Grey-1Year Warranty (As Provided By Oem) - Service By Customer Service Of Oem Only.Hsn:8471. Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. , Electromyography (Open) , The System Should Be Supplied With Minimum 16 High Speed Wireless Emg Channel With Built In Imu Sensor. Should Have Analog+ Digital Base Station • Should Have Analogy Output Option To Facilitate Integration With Third Party Hardware And Software Sensor Should Have Fixed Inter Sensor Delay Of 0.5 Milliseconds Or Less Sensors Should Have Fixed Spacing Between Electrodes Preferably Less Than 15 Mm To Avoid Motion Artifacts And Cross-Talk Sensor Contacts Should Be Made Up Of A Metal For Better Contact And Better-Quality Signal Should Be Supplied With A Charging/Transmitting Station That Communicates With Sensors To Get Information On Their Charging, Recording And Signal Strength Sensors, Sensor Skin Interface, Cable, Power Adapter And Accessories Sensors Facilitate Emg And Imu Measurements Emg Data Analysis Software For Stand-Alone Usage With Live Recording Of At Least 32 Channels And Analysis For Both Online And Offline Modes. Trigger Module Package Analog Adapter With Cable For Dynamometer Integration. • Should Have Option For Real Time Data Streaming To Computational Softwares Such As Mat Lab. Mobile Emg Suite For Outdoor Applications Technical Support For The Lifetime Or At Least For A Period Of 05 Years. The System Should Be Supplied With Sensor Docking Unit And Charging System The System Should Be Supplied With Double Sided Adhesive Stickers (At Least 5000) And Double-Sided Adhesive Tape Rolls (At Least 20). The System Should Be Supplied With At Least 2000 Hz Of Sampling Rate Or More Per Sensor. The System Should Have A Baseline Noise < 1 ?V Or Better. The Emg System Should Have +20,000 ? Vemg Input Range Or Better. The System Should Have Software Controlled Digital Filtering, The System Should Have Shielded Cables For Minimal Artifact. The Software Should Allow Video Recording During Emg Data Recording Should Have At Least 8 Hours Of Battery Backup • Should Have Wireless Working Range Of At Least 40M Or More To Capture Data During Various Sport Specific Movements, Should Be Configurable To 32 Channels In Future. The Emg System Should Be Integrated With 3D Motion Analysis, Force Plate, Isokinetic Dynamometer, Instrumented Treadmill, Imu, Eye Tracking, Video Analysis Etc. The Necessary Third-Party Hardware/ Software Should Be Supplied By The Seller For Integration Of Emg With Other Systems. Laptop I7 (Latest Generation) With 32Gb Ram Or More, 2Tb Ssd, At Least 15.6-Inch Screen And Laser Printer With Copy/Scan/Print To Generate And View Report And Additionally A 32-Inch Monitor For Dual Display. Usfda, Iso & Euiec Certificates Or Equivalent. Installation At The Institute And Training To The Users By Experts Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. , Timing Gates (Open) , It Should Be A Wireless Speed Gate With 12 Gates And Provision For Increasing Gates Up To 15 Gates/Splits Or More With Split Distance Fully Customizable To Perform Variety Of Testing (Can Have Splits At 1 Meter Or 10 Meters Or Customized Distance). It Should Be Photocell & Reflector System Only (Light Or Laser Based) Considering Flexibility It Offers To Use Variety Of Testing Protocols With Visual Cue (Light System Provide A Cue To The Athlete To Change Direction) I.E. Single Or Dual Feedback Functions For Athletes. It Should Have An Accuracy Of Minimum 1 Hundredth Of A Second (1/1000Th Of A Second) Or Beyond, With A System To Eliminate Errors Caused By Hands, Feet And Other Body Parts, Equipment (To Provide Most Accurate Data) Must Have Error Correction Processing (Ecp) Inside The Timing Unit. Wireless Range: - Should Be Able To Control Gates Wirelessly With A Range Up To 180-200 Meters. It Should Have Functionalities To Provide 6 Options When Using Different Accessories A. Auto Beam Break B. In-Beam C. Reactive D. Start Pad E. Vibration (Reaction Time Measures) F. Rfid Various Accessories Should Be Integrated With Timing Gates Thus Providing Various Testing Possibilities Of Athletes. It Should Integrate With A Jump Mat (Accessories) For Plyometric Training And Explosive Power Measurement With Multiple Jump Testing Option On Jump Mats. Tests & Drills To Be Measured System Must Be Able To Measure- I. Linear (Straight Line Sprints), Shuttles With Customized Split Distance. Ii. Yoyo, Beep Tests (With Custom Customized Time Interval For Endurance Testing) Iii. Planned, Unplanned Change Of Direction For Agility Testing. Iv. Multiple Reactive Movements. V. Reaction Time Measure For Starting Blocks Any Customized Tests/ Drill With All 6 Or More Gates And No Restrictions On Number Of Customized Drills To Provide More Flexibility In Testing. • Mobile/Tablet Applications & Web Application: I. System Should Be Controlled By And Operated By Tablet/Laptop/Smartphone (Mobile Applications: -Should Have Both Ios & Android Mandatory Considering Large Android Phone User Base In India Along With Ios Application) And Ii. Must Have A Cloud Web Application Platform For Tracking Performance Variables Of 1000 Or More Athletes At One Go For Various Testing. Utility Of Mobile Applications: - I. Flexibility To Perform Test: -Mobile/Tablet Applications Should Have Functionality To - A. Pick Any Athlete From Large Pool (1000 Or More Athlete) B. Pick Any Drill Or Test To Be Conducted And Ability To Customize A Test With All 4 Or More Gates. C. To Visually Display Gates On Mobile Screen To Understand How To Perform A Test/Drill. Application To Automatically Detect Setup Of Gates. Ii. It Should Provide Real Time Data Of Performance, Reaction Time, Speed, And Agility. Iii.Single Or Multiple User With Authorized Access Control- Only Authorized Single Or Multiple Users Admins Should Have Access To Operate Application For Data Security And Data Access. Should Automatically Send Data To The Cloud Application Once Connected To Internet. Software License To Be Valid For 3 Years. Utility Of Web Application: - Functionality Of Web Application: - I. Automatically Populate Data Collected By Mobile Applications. Ii. Should Be Able To Compare Single Athlete Data Historically From Different Trials Or Compare Various Athletes For A Test Or A Drill Over Any Time Period. Iii. Should Be Able To Manage Athletes (By Creating Sports Specific Teams) Iv. Should Be Able To Download Data In Pdf, Excel And Ability To Customize These Reports V. Software License To Be Valid For 3 Years. Integration With 3Rd Party Ams System: -Software Should Have Functionality To Integrate Ams In Near Future Automatically, A Software Must Have Api Available For Seam Less Integration Of All/ Selected Data Of Speed Gates Automatically With Number Of World Leading Ams Systems And This Must Be Automated With Few Clicks Only. Rechargeable Battery Based Systems Should Have At Least 8 Hours Backup Or More. The System Should Be Robust Enough To Be Used In Various Weather Conditions. Should Have Height Adjustable Tripod Stands To Accommodate Various Sports Activities And Test Protocols. Should Provide One (1) Ipad Of Desired Specification To Run The Application (With Minimum 1 Year Warranty) Warranty For 2 Years. Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. , Kinematic Analysis System (Open) , . Marker-Based And Markerless (Ai Based) Biomechanical System For Two-Dimensional (2D) Analysis Of Gait Analysis Including Walking And Running Activities, Posture And Other Sports Activities. 2. Biomechanical Motion Analysis Software (Pre-Installed In Computer) Within Built Modules For Standing & Sitting Posture Analysis, Walking Gait Analysis & Running Gait Analysis, Compatible With A Suitable Operating System. 3. It Should Allow Measurement Of Joint Angles & Other Data From Sports Specific Activities Like Jump, Squat, Golf, Tennis Etc. 4. It Should Also Have Features For Marker-Less Assessment Of Functional Activities Like Squats And Other Range Of Motions Of The Body During Various Activities. 5. It Should Be Able To Analyze The Anterior, Posterior, Left & Right Lateral Views Of The Subject And Provide The Following Parameters: (A) Walking Gait Analysis: Rear Foot Eversion/Inversion, Lateral Pelvic Drop, Knee Flexion/Extension, Hip Flexion / Extension, Ankle Plantar /Dorsiflexion, Knee Ab /Adduction, Stance Phase % - Swing Phase %, Step Length, Stride Length, Gait Velocity Etc. Data To Be Measured For Both Left And Right Extremities (B) Running Gait Analysis: Rear-Foot Eversion/Inversion, Lateral Pelvic Drop, Trunk Side Bending, Crossover Gait, Knee Flexion, Leg Inclination Angle, Knee Toe-Alignment, Hip Extension, Ankle Plantar Flexion, Net Vertical Oscillation Of Center Of Mass, Knee Ab /Adduction, Ground Contact Time Etc.. Data To Be Measured For Both Left And Right Extremities. (C) Posture Analysis: Major Postural Deviations Like Rear-Foot Eversion /Inversion, Forward Head Posture, Shoulder Protraction, Genu Recurvate, Lateral Head Tilt, Shoulder Level, Lateral Pelvic Drop, Lateral Trunk Sway, Q Angle (D) Sitting Posture Angle: Viewing Angle, Viewing Distance, Forward Head Angle, Elbow Flexion/Extension, Trunk Flexion/Extension, Knee Flexion/Extension, Hip Knee Alignment (E) Bike Fitting: Major Parameters Like Ankle Plantar Flexion /Dorsiflexion, Knee Flexion/ Extension, Hip Flexion, Hip Vertical Travel, Back Angle, Elbow Angle, Armpit Angle, Kops, Knee Tracking. (F) Squat Analysis: Major Parameters Like Descent: Ascent Ratio, Squat Stance Width, Heel Rise Detection, Head Tilt, Shoulder Tilt, Lateral Trunk Tilt, Pelvic Tilt, Frontal Knee Alignment, Knee-Toe Alignment, Trunk Inclination (Sagittal Plane), Tibia Inclination (Sagittal Plane), Knee Flexion (Depth Of Squat). 6. It Should Be Able To Generate Organized Reports With Following Features: (A) Data Represented In Tabular & Photographic Form (B) In Built Reference Ranges For Every Parameter Measured. (C) All Data Lying Outside Reference Ranges To Be Highlighted In Bold (D) Automatic Documentation Of All Observations And Abnormal Biomechanics In Form Of Notes (With Choice Of Hindi Or English Language If Needed). (E) Automatic Summary Of All Reports Should Be Generated. 7. It Should Have An Option To Export All Data To Excel Sheets 8. It Should Have An Inbuilt Comparison Feature That Generates Post Comparison Reports To Monitor Changes In Patients Posture And Gait. 9. It Should Have An In-Built Data Base Feature For Storing Analysis Data. 10. Software Should Use Ai (Artificial Intelligence) Models To Provide Markerless Analysis. 11. Software Should Also Use Ai (Artificial Intelligence) Models To Aid In Marker Digitization In Case Of Marker Based Analysis. 12. Motion Capture Cameras Supporting Video Capture In Outdoor Conditions (Running Track) As Well As Indoor Conditions (Floor, Walkway & Treadmill). Camera Specifications: (A) Wired Cameras-04 In Numbers With Capture Rate Up To 60 Fps. (B) Wirelesscameras-02 In Numbers With Capture Rate Up To 240 Fps. 12. The System Should Have Data Transfer Cables And Connector Cables For Camera Along With Tripods For Mounting Of Cameras. 13. Marker Set (With Marker Placement Guide) For Standing Posture, Walking Gait Analysis, Running Gait Analysis And Bike Fitting With Reusable Markers Or Disposable Markers (Adequate In Number For Conducting At Least 100 Tests Each) 14. Compression Clothing For Lower Body & Upper Body Should Be Provided. 15. Quality Clearance For Cameras: Usfcc/ Euce/ Isobis (Either Of The Certifications). 16. Should Be Safe And Non-Invasive, Easy To Use. 17. Carry Case/Bag For Storing And Carrying All Hardware Equipment To Be Provided. 18. In Person Training, Virtual Assistance & Technical Support For System Operation. 19. The Biomechanical Analysis Software Should Have License Validity Along With All Updates And Bug Fixes For A Minimum Period Of 10 Years. 20. The System Should Come With A Hardware Warranty Of 3 Years. 21. Computer Specifications: Intel 5Th Generation Processor Or Better, 8 Gb Ram, Windows 10/11, At Least 2 Usb Ports. , Foot Pressure Analysis System (Open) , 1. The Number Of Sensors Should Be Between 2900 To 4000. 2. The Active Sensor Area Should Be At Least 375 X 375 Mm. 3. The System Should Be Able To Perform Static (Standing) & Dynamic (Walking) Assessment And Provide Data Of Foot Pressure Distribution During These Activities. 4. It Should Also Have Capability To Perform Sway (Balance) Assessments During Eyes Open And Closed Conditions. 5. System Should Be Able To Generate Automated Remarks For Symmetries Of Pressure Distribution. 6. System Should Be Able To Identify Change In Pressures With & Without Footwear /In Soles. 7. Option Of Comparing Patients Data Over Time Should Be Provided. 8. Option Of Exporting Report Data In Excel Format Should Be Available. 9. Facility To Email Report With Patient Information Should Be Provided. 10. System Should Have Wired Operation. 11. System Should Work Without The Internet. 12. Should Have Operating Temperature Range Between 5° C To 50°C 13. Frequency Range Should Be At Least 100 Hz 14. Pressure Range Should Be Between 1 To 150 Psi 15. Sensor Resolution Should Be Equal To Or More Than 2 Per Cm^2 16. Sensor Technology Should Be Piezo Resistive 17. Should Be Supplied With A Padded Carry Bag. 18. Should Be Supplied With 2 Additional Dummy Platforms 19. System Should Not Need A Separate Electrical Supply And Should Draw Power From The Computer. 20. The Complete System Should Have 3-Year Hardware Warranty Period Along With Software Updates And Tech Support. Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
15.
Housing Urban and Rular Development #11306856 AOC
Tender For M.O.W. Work (Additional Room) In Bunglow No. Eg-9/3 And Ek-9/3 Under Section No.1 Survey Sub Dn. Bhopal- 1 M.O.W. Work (Additional Room) in Bunglow No. EG-9/3 and EK-9/3 Under Section No.1 Survey Sub Dn. Bhopal 1st Call P.A.C. 29.64 Lakh,as per Building SOR wef 01-01-2024 Schedule Attached Complition period 90 Days Please Enable Macros to View BoQ information SCHEDULE OF ITEMS Name of work : M.O.W. Work (Additional Room) in Bunglow No. EG-9/3 and EK-9/3 Under Section No.1 Survey Sub Dn. Bhopal Probable Amount of contract : Rs. 29.64 Lacs. (Rs. in Figures) : Time Alloved : 6 months i/c rainy season S.No SOR Item Particulers of Item Unit Rate Remarks 2 2.4 2.4.1 beyond 30 cm girth up to and including 60 cm girth each 350.0 2.4.2 beyond 60 cm girth up to and including 120 cm girth each 1150.0 2.4.3 beyond 120 cm girth up to and including 240 cm girth each 3500.0 2.4.4 above 240 cm girth each 6300.0 3 2.7 2.7.1 Ordinary rock cum 287.0 2.7.2 Hard rock (requiring blasting) cum 519.0 2.7.3 Hard rock (blasting prohibited) cum 828.0 4 2.25 2.25.1 All kinds of soil. cum 30.0 2.25.2 Ordinary or hard rock. cum 53.0 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete cum 672.0 Note: - Maximum thickness of this layer shall be 20 cm. 5 2.27 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) cum 393.0 2.27.2 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm cum 331.0 6 2.28 2.28.1 All kinds of soil. each 42.0 2.28.2 Ordinary rock each 68.0 2.28.3 Hard rock (requiring blasting) each 138.0 2.28.4 Hard rock (blasting prohibited) each 151.0 7 2.3 2.30.1 Along external wall where the apron is not provided using chemical emulsion@ 7.5 liters / sqm of the vertical surfaceof the substructure to a depth of 300mm including excavation channel along the wall and rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 36.0 2.30.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 42.0 2.30.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. sqm 199.0 2.30.4 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling 10mm dia and 200mm deep holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 50.0 2.30.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litresper hole by drilling 6 mm dia holes at downward angle of 45 degree at 150mm centre to centre and sealing the same. metre 201.0 8 2.41 2.42.1 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. cum 331.0 9 4.1 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-25 – Grade concrete cum 6338.0 4.1.1.2 M-20 – Grade concrete cum 4933.0 4.1.1.3 M-15 – Grade concrete cum 4471.0 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) cum 3890.0 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete cum 4403.0 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) cum 3808.0 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate cum 3474.0 4.1.3 With fly ash. Note: No fly ash is to be added to Portland Pozzolona cement in any case which itself contains fly ash. 10 4.2 string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1 With 20mm nominal size graded stone aggregate 4.2.1.1 M-25 – Grade concrete Cum 6582.0 4.2.1.2 M 20 – Grade concrete Cum 5177.0 4.2.1.3 M 15 – Grade concrete Cum 4714.0 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate Cum 4134.0 4.2.2 With 40mm nominal size graded stone aggregate 4.2.2.1 M-15 - Grade concrete cum 4647.0 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate cum 4052.0 11 4.3 4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. Sqm 169.0 4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. sqm 267.0 4.3.3 Above plinth: Columns, pillars, posts and struts. Sqm 356.0 12 4.6 4.6.1 M-25 (With 20mm nominal size graded stone aggregate) cum 5095.0 4.6.2 M-20 (With 20mm nominal size graded stone aggregate) cum 5558.0 4.6.3 M-15 (With 20mm nominal size graded stone aggregate) cum 5095.0 4.6.4 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. cum 4515.0 4.1 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size). Sqm 200.0 13 5.1 5.1.1 M-20 Grade Concrete cum 6153.0 5.1.2 M-15 Grade Concrete cum 5397.0 14 5.2 5.2.1 M-20 Grade Concrete cum 6231.0 15 5.3 5.3.1 M-20 Grade Concrete cum 6541.0 16 5.4 5.4.1 M-20 Grade Concrete cum 5542.0 17 5.5 5.5.1 M-20 Grade Concrete cum 6906.0 18 5.6.1 5.6.1 M-20 Grade Concrete cum 6337.0 19 5.7.1 5.7.1 M-20 Grade Concrete cum 5448.0 20 5.9.1 5.9.1 Foundations, footings, bases of columns, etc. for concrete upto plinth level sqm 190.6 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 Uptoplinthlevel. sqm 219.0 5.9.2.2 Above plinth upto 3.6 m height from plinth level sqm 330.0 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. sqm 40.0 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 439.6 5.9.4 Shelves(Cast in situ) sqm 290.0 5.9.5 Lintels, beams, girders, bressumers and cantilevers sqm 356.0 5.9.6 Columns, P i l l a r s , Piers, Abutments, sqm 471.2 Posts and Struts. 5.9.7 Stairs, (excluding landings) except spiral- Staircases. sqm 435.7 5.9.8 Spiral staircases (including landing). sqm 450.0 5.9.9 Arches, domes,vaults upto 6m span sqm 1141.6 5.9.10 Extra for arches, domes, vaults exceeding 6 m span sqm 451.3 5.9.11 Chimneys and shafts sqm 294.0 5.9.12 Coffer/waffle slab of any size or shape as shown in the drawing. sqm 1481.0 5.9.15 Extra for shuttering in circular work or any other geometrical shape (20% of respective centering and shuttering items). sqm 0.2 5.9.16 Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. sqm 191.0 5.9.17 Cornices and mouldings sqm 565.0 5.9.18 Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. sqm 529.6 5.9.19 Weather shade, Chajjas, corbels etc., including Edges. sqm 534.2 5.9.20 Suspended floors, roofs, landings, balconies and Access platform. With water proof ply 12 mm thick. (item to be executed with prior permission of C.E./S.E. in case of B & R works . sqm 575.35 5.9.21 Lintels, beams, columns, girders, bressumers and cantilevers with waterproof ply 12 mm thick (item to be executed with prior permission of C.E./S.E. in case of B & R works . sqm 521.2 21 5.1 5.10.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). sqm 212.0 22 5.12 5.12.1 50 mm thick sqm 790.0 5.12.2 40 mm thick sqm 689.0 5.12.3 25 mm thick sqm 598.0 23 5.16 5.16.1 Mild steel and Medium Tensile steel bars. kg 78 .00 5.16.2 Hard drawn steel wire kg 75.0 5.16.3 Cold twisted bars (CTD) kg 81.0 5.16.4 Hot rolled deformed bars kg 81.0 5.16.5 Hard drawn steel wire fabric kg 76.0 5.16.6 Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 kg 80.0 5.16.7 Thermo-Mechanically Treated bars. FE 500 conforming .to IS 1786 kg 77.0 5.16.8 Corrosion resistance Steel bar Grade Fe-500 D & above , use with prior permission of C.E. Kg 98.0 24 5.22 5. 22.1 12 mm thick sqm 402.0 5. 22.2 25 mm thick sqm 574.0 5. 22.3 50 mm thick sqm 674.0 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design. 5. 23.1 Non-asbestos fibre cement board 6 mm thick as per IS: 14862. 5. 23.1.1 150mm wide. RM 102.0 5. 23.1.2 200mm wide. RM 137.0 5. 23.1.3 250mm wide. RM 153.0 5. 23.2 Aluminium fluted strips 3.15mm thick. 5. 23.2.1 150 mm wide. RM 483.0 5. 23.2.2 200 mm wide. RM 646.0 5. 23.2.3 250 mm wide. RM 725.0 5. 23.3 Stainless steel Grade 304 plate-1.0 mm thick 5. 23.3.1 150 mm wide. RM 367.0 5. 23.3.2 200 mm wide. RM 443.0 5. 23.3.3 250 mm wide. RM 555.0 25 5.24 5.24.1 Preparation of grooves RM 18.5 5.24.2 Preparation of Drip course RM 30.0 26 5.32 5.32.1 Non pigmented wet curing compound sqm 93.0 5.32.2 Pigmented wet curing compound. sqm 100.0 27 6.1 6.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5818.0 6.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5626.0 28 6.2 6.2.1 Cement mortar 1:4 (1 cement : 4 sand) cum 6012.0 6.2.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5821.0 6.3 Brick work with well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process, crushing strength not lessthan 40kg /cm2 and water absorptionnot more than 15% in foundation and plinth i/c curing etc. complete. 6.3.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5252.0 6.3.2 Cement Mortar 1:6 (1 cement:6 sand). cum 5061.0 29 6.4 6.4.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5446.0 6.4.2 Cement Mortar 1:6 (1 cement:6 sand). cum 5255.0 30 6.5 6.5.1 Cement mortar 1:4 (1 cement : 4 sand) cum 4347.0 6.5.2 Cement Mortar 1:6 (1 cement: 6 sand). cum 4155.0 31 6.6 6.6.1 Cement mortar 1:4 (1 cement : 4 sand) cum 4541.0 6.6.2 Cement Mortar 1:6 (1 cement : 6 sand) cum 4350.0 32 6.7 6.7.1 Having 100 kg / cm2 average compressive strength. 6.7.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5384.0 6.7.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5162.0 6.7.2 Having 75 kg / cm2 average compressive strength. 6.7.2.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5271.0 6.7.2.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5049.0 6.7.3 Having 50 kg / cm2 average compressive strength. 6.7.3.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5158.0 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4936.0 33 6.8 6.8.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5287.0 6.8.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5095.0 34 6.9 Cement Mortar 1:4 ( 1 cement : 4 sand) 35 6.12 6.12.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 697.0 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 673.0 36 6.13 6.13.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 639.0 6.13.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 615.0 37 6.14 6.14.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 546.0 6.14.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 522.0 38 6.15 6.15.1 Having 100 kg/cm2 average compressive strength. 6.15.1.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 570.0 6.15.1.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 551.0 6.15.2 Having 75 kg/cm2 average compressive strength. 6.15.2.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 524.0 6.15.2.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 505.0 6.15.3 Having 50 kg/cm2 average compressive strength. 6.15.3.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 479.0 6.15.3.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 459.0 39 6.37 6.37.1 Having100 kg / cm2 average compressive strength. 6.37.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5115.0 6.37.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4904.0 6.37.2 Having75 kg / cm2 average compressive strength. 6.37.2.1 Cement mortar 1:4 (1 cement : 4sand) cum 5007.0 6.37.2.2 Cement mortar 1:6 (1 cement : 6sand) cum 4797.0 6.37.3 Having50 kg / cm2 averagecompressive strength. 6.37.3.1 Cement mortar 1:4 (1 cement : 4sand) cum 4900.0 6.37.3.2 Cement mortar 1:6 (1 cement : 6sand) cum 4689.0 40 9.3 9.3.1 Sal wood cum 76229.0 9.3.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. cum 77538.0 9.3.3 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 64833.0 41 9.4 9.4.1 Second class teak wood cum 9062.0 9.4.2 Sal wood cum 7131.0 9.4.3 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. cum 7275.0 9.4.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 6030.0 9.5.4.1 35 mm thick sqm 1089.0 9.5.4.2 30 mm thick sqm 969.0 42 9.6 9.6.1 Second class teak wood sqm 2215.0 9.6.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood sqm 1763.0 9.6.3 15mm thick Factory made Kiln seasoned, chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood. sqm 971.0 9.6.4 Ply wood 5 ply, 9 mm thick : 9.6.4.1 Decorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type. sqm 1439.0 9.6.4.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type sqm 1369.0 9.6.5 Ply wood 7 ply, 9 mm thick : 9.6.5.1 Decorative plywood both side decorative veneer (Type- I) conforming to IS 1328 BWR type. sqm 1861.0 9.6.5.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-1) conforming to IS 1328 BWR Type sqm 1650.0 9.6.6 Particle Board 12 mm thick 9.6.6.1 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. sqm 791.0 9.6.6.2 Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. sqm 1087.0 9.6.6.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked. sqm 1333.0 9.6.6.4 Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS: 12823 marked. sqm 1390.0 9.6.6.5 Coir Veneer Board (conforming to IS 14842) 12 mm thick sqm 1298.0 9.6.7 Float glass panes 9.6.7.1 4 mm thick glass pane (weight not less than 10 kg/sqm) sqm 973.0 9.6.7.2 5 mm thick glass pane (weight not less than 12.5 kg/sqm) sqm 1046.0 9.6.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading sqm 1532.0 9.6.8.1 4mm to 5mm thick integral PVC form sheet with Celluka finish surface on both side with density not less than 600 kg/cum sqm 580.0 9.6.8.2 4mm to 5mm thick laminated PVC form sheet with density not less than 600 kg/cum, laminated on both sides by 0.12 mm thick laminated sheet with density not less than 1400 kg/cum sqm 754.0 43 9.14 9.14.1 Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. Sqm 170.0 9.14.2 ISI marked M.S. pressed butt hinges bright finished of required size For 2nd class teak wood and other class of wood shutters. Sqm 53.0 44 9.15 9.15.1 Panelled or panelled and glazed shutters : 9.15.1.1 Using ISI marked anodised aluminium butt hinges with necessary screws. Sqm 2736.0 9.15.1.2 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 2753.0 9.15.2 Glazed shutters : 9.15.2.1 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. Sqm 2815.0 9.15.2.2 2nd class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 2759.0 45 9.16 9.16.1 12 mm thick Sqm 555.0 9.16.2 18 mm thick Sqm 654.0 46 9.17 9.17.1 18 mm thick Sqm 1270.0 9.17.2 25 mm thick Sqm 1383.0 47 9.18 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 2823.0 9.18.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 2648.0 9.18.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws. Sqm 2465.0 48 9.19 9.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 1870.0 9.19.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 1696.0 9.19.3 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 1623.0 49 9.2 9.21 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). Sqm 401.0 9.22 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : 9.22.1 Rectangular or square. Sqm 157.0 9.22.2 Circular. Sqm 244.0 50 9.25 9.25.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.1.1 Second class teak wood. Sqm 3174.0 9.25.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2599.0 9.25.1.3 Kiln seasoned selected class of sheesham wood. Sqm 2452.0 9.25.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.2.1 Second class teak wood. Sqm 3291.0 9.25.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2716.0 9.25.2.3 Kiln seasoned selected class of sheesham wood. Sqm 2569.0 9.25.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.3.1 Second class teak wood. Sqm 2797.0 9.25.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2306.0 9.25.3.3 Kiln seasoned selected class of sheesham wood. Sqm 2179.0 9.25.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.4.1 Second class teak wood. Sqm 2914.0 9.25.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2423.0 9.25.4.3 Kiln seasoned selected class of sheesham wood. Sqm 2296.0 9.26.2 30 mm thick shutters Sqm 2102.0 51 9.57 9.57.1 300x16 mm Each 170.0 9.57.2 250x16 mm Each 157.0 52 9.58 9.58.1 250x10 mm Each 68.0 9.58.2 200x10 mm Each 60.0 9.58.3 150x10 mm Each 42.0 9.58.4 100x10 mm Each 35.0 53 9.6 9.60.1 300x20x6 mm Each 72.0 9.60.2 250x20x6 mm Each 67.0 54 9.61 9.61.1 125 mm Each 27.0 9.61.2 100 mm Each 25.0 9.61.3 75 mm Each 24.0 55 9.62 9.62.1 150 mm Each 23.0 9.62.2 115 mm Each 20.0 9.62.3 90 mm Each 17.0 56 9.63 9.63.1 300 mm weighing not less than 200 gms. Each 40.0 9.63.2 250 mm weighing not less than 150 gms. Each 34.0 9.63.3 200 mm weighing not less than 120 gms. Each 28.0 57 9.65 9.65.1 300x16 mm Each 389.0 9.65.2 250x16 mm Each 326.0 9.65.3 400x16mm Each 601.0 58 9.66 9.66.1 250x10 mm Each 148.0 9.66.2 200x10 mm Each 93.0 9.66.3 150x10 mm Each 71.0 9.66.4 100x10 mm Each 50.0 59 9.68 9.68.1 300x20x6 mm Each 211.0 9.68.2 250x20x6 mm Each 173.0 9.69 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : Each 9.69.1 125 mm Each 60.0 9.69.2 100 mm Each 54.0 9.69.3 75 mm Each 48.0 60 9.7 9.70.1 150 mm each 37.0 9.70.2 115 mm each 33.0 9.70.3 90 mm each 26.0 61 9.73 9.73.1 125x64x1.90 mm each 67.0 9.73.2 100X58X1.90 mm each 59.0 9.73.3 75x47x1.80 mm each 39.0 9.73.4 50x37x1.50 mm each 25.0 62 9.74 9.74.1 125x64x2.50 mm each 76.0 9.74.2 100x60x2.50 mm each 60.0 9.74.3 75x50x2.50 mm each 46.0 63 9.76 9.77 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 9.77.1 125x85x5.5 mm (heavy type) each 456.0 9.77.2 125x70x4 mm (ordinary type) each 148.0 9.77.3 100x85x5.5 mm (heavy type) each 387.0 9.77.4 100x70x4 mm (ordinary type) each 117.0 9.77.5 75x65x4 mm (heavy type) each 145.0 9.77.6 75x40x2.5 mm (ordinary type) each 74.0 9.77.7 50x40x2.5 mm (ordinary type) each 32.0 64 9.78 9.78.1 150x125x27x5 mm each 385.0 9.78.2 125x125x27x5 mm each 345.0 9.78.3 100x125x27x5 mm each 304.0 9.78.4 75x100x20x3.2 mm each 239.0 65 9.79 9.79.1 400x10 mm each 400.0 9.79.2 250x10 mm each 329.0 9.79.3 200x10 mm each 261.0 9.79.4 150x10 mm each 221.0 9.79.5 100x10 mm each 142.0 66 9.8 9.80.1 300x16x5 mm each 237.0 9.80.2 250x16x5 mm each 225.0 67 9.81 9.81.1 125 mm each 205.0 9.81.2 100 mm each 181.0 9.81.3 75 mm each 141.0 68 9.82 9.82.1 300x16mm each 407.0 9.82.2 250x16mm each 374.0 69 9.87 9.87.1 40 mm each 144.0 9.87.2 50 mm each 150.0 9.87.3 65 mm each 162.0 9.87.4 75 mm each 185.0 70 9.99 9.99.1 Size 40 mm each 144.0 9.99.2 Size 50 mm each 156.0 9.99.3 Size 65 mm each 167.0 9.99.4 Size 75 mm each 196.0 71 9.101 9.101.1 300x16mm each 268.0 9.101.2 250x16mm each 245.0 72 9.102 9.102.1 400X10mm each 260.0 9.102.2 300x10mm each 198.0 9.102.3 250x10mm each 164.0 9.102.4 200x10 mm each 113.0 9.102.5 150x10 mm each 91.0 9.102.6 100x10 mm each 73.0 73 9.103 9.103.1 300x16x5mm each 255.0 9.103.2 250x16x5mm each 243.0 74 9.108 9.108.1 125x75x4 mm each 115.0 9.108.2 125x63x4 mm each 108.0 9.108.3 100x75x4 mm each 95.0 9.108.4 100x63x4 mm each 93.0 9.108.5 100x63x3.2 mm each 90.0 9.108.6 75x63x4 mm each 77.0 9.108.7 75x63x3.2 mm each 75.0 9.108.8 75x45x3.2 mm each 67.0 75 9.109 9.109.1 300x16 mm each 241.0 9.109.2 250x16 mm each 195.0 76 9.11 9.110.1 400X10mm each 123.0 9.110.2 300x10 mm each 114.0 9.110.3 250x10 mm each 102.0 9.110.4 200x10 mm each 82.0 9.110.5 150x10 mm each 69.0 9.110.6 100x10 mm each 55.0 77 9.111 78 9.113 9.113.1 125 mm each 75.0 9.113.2 100 mm each 55.0 9.113.3 75 mm each 46.0 79 9.114 9.114.1 Single rubber stopper each 35.0 9.114.2 Twin rubber stopper each 86.0 80 9.116 81 9.117 82 9.126 83 9.127 84 9.128 85 9.129 9.129.1 Triple strip vertical type. each 28.0 9.129.2 Double strip (horizontal type). each 23.0 9.131 Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in-charge. 9.131.1 300mm long each set 209.0 9.131.2 450mm long each set 256.0 9.131.3 500mm long each set 302.0 86 9.132 87 9.133 9.133.1 Marine plywood conforming to IS: 710 sqm 1591.0 9.133.2 Fire retardant plywood conforming to IS: 5509. sqm 1660.0 88 9.134.1 9.134.1 1.5 mm thick. sqm 851.0 89 9.134.2 90 9.138 9.138.1 12 mm thick. sqm 919.0 9.138.2 18 mm thick. sqm 1161.0 9.138.3 25 mm thick. sqm 1230.0 91 9.139 92 9.14 9.140.1 18 mm thick sqm 1493.0 9.140.2 25 mm thick sqm 2017.0 93 9.145 9.145.1 Board 12 mm thick sqm 811.0 9.145.2 Board 18 mm thick sqm 943.0 9.146 Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). 9.146.1 18 mm thick sqm 1055.0 9.146.2 25 mm thick sqm 1420.0 94 9.147 95 9.148 96 9.15 9.150.1 12 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 1210.0 9.150.2 18 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 1320.0 97 9.158 9.158.1 Extruded section Profile size 48x40 mm. metre 203.0 9.158.2 Extruded section Profile size 42x50 mm. metre 208.0 98 9.165 99 9.166 9.166.1 Plain PVC door shutters. sqm 2026.0 9.166.2 Pre laminated PVC door shutters. sqm 2490.0 100 9.167 101 9.168 as panel. The styles andrails will be mitred cut and joint with the help of PVC solvent cement and self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mmand 15 mm integrally extruded in the middle of the lock rail and fixed with styles with the help of PVC solvent cement and self driven self tapping screws of size 100 mmx8 mm complete as per manufacturers specifications and direction of Engineer-in-charge: 9.168.1 Non decorative finish. sqm 2026.0 9.168.2 Decorative finish (both side wood grained finish). sqm 2432.0 102 9.169 9.169.1 Single rebate (75 mm X 50 mm) RM 459.0 9.169.2 Single rebate (100 mm X50 mm) RM 720.0 9.169.3 Single or double rebate (125 mm X 65 mm) RM 923.0 103 9.17 9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 2250.0 9.170.2 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 3250.0 9.170.3 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 3693.0 9.170.4 35 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 4135.0 104 9.186 105 9.187 9.187.1 Casement Window (Outward/Inward opening) with hinge System. 9.187.1.1 Frame (50 mm x 50mm) metre 422.0 9.187.1.2 Sash (Style and Rail) (62 mm x 34 mm) metre 403.0 9.187.1.3 Mullion (intermediate Section) (66mm x 50 mm) metre 434.0 9.187.1.4 ‘T Profile (one vertical length in between two shutters) (24mm x 34.5mm) metre 99.0 9.187.1.5 Glazing bead (12mm x 18mm) metre 130.0 9.187.2 Casement Window (With friction hinge and outward opening) 9.187.2.1 Casement Frame (67mm x 62mm) metre 495.0 9.187.2.2 Casement Window Sash/Mullion (67mm x75mm) (style, rail and intermediate section) metre 519.0 9.187.2.3 Casement Glazing bead (35mm x 18 mm) metre 178.0 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67mm x 52mm) metre 9.187.3.2 Sliding window Sash (60mm x 44mm) metre 529.0 9.187.3.3 Sliding Interlock for Window (one vertical length in each shutter)(45.5 mm x 28 mm) metre 139.0 9.187.3.4 Sliding Glazing bead (35 mm x 18 mm) metre 178.0 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67mm x 52mm) metre 539.0 9.187.4.2 Sliding Door Sash (80mm x 44mm) metre 653.0 9.187.4.3 Sliding Interlock for Door (one vertical length in each shutter) (45.5 mm x 28 mm) metre 139.0 9.187.4.4 Sliding Glazing bead (35 mm x 18 mm) metre 178.0 106 9.188 9.188.1 200 x 19 x 1.9 mm each 321.0 9.188.2 250 x 19 x 1.9 mm each 369.0 9.188.3 300 x 19 x 1.9 mm each 462.0 9.188.4 350 x 19 x 1.9 mm each 526.0 9.188.5 400 x 19 x 1.9 mm each 636.0 107 9.189 108 9.191 109 9.192 110 9.193 111 9.194 9.194.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) sqm 6798.0 9.194.2 Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). sqm 6221.0 9.194.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). sqm 4842.0 9.194.4 Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) sqm 6681.0 9.194.5 Casement window duble panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm.) sqm 6942.0 9.194.6 Casement cum fixed panel window having both and single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm & mullion67 x 80 all having wall thickness of 2.3 ±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm. Upto 5.00 sqm.) sqm 5290.0 9.195 Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (ifrequired) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). 9.195.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) sqm 4860.0 9.196 Providing and fixing made UPVC white colour casement/ casement cum fixed glazed door comprising of UPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made fromroll forming process of required length(shape & size according to UPVC profile),UPVC 9.196.1 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). sqm 7085.0 9.196.2 Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±.0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm). sqm 7063.0 9.197 Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profileof frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) 9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) sqm 5060.0 9.197.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). sqm 6880.0 9.197.3 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm). sqm 5134.0 9.197.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area ofwindow above 1.75 sqm). sqm 6371.0 9.197.5 Three track three panels sliding window made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) sqm 5913.0 112 9.198 9.198.1 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto sqm 4332.0 4.00 sqm). 9.198.2 Two track four panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). sqm 3532.0 9.199 Providing and fixing factory made UPVC white colour sliding glazed door comprising of UPVC multi-chambered frame with in- built roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension UPVC extruded glazing beads, UPVC extruded interlock and UPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), 9.199.1 Two track two panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm upto 10.00 sqm). sqm 3676.0 9.199.2 Two track four panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 8.00 sqm upto10.00 sqm). sqm 3810.0 9.199.3 Three track three panels sliding door made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) sqm 4361.0 9.199.4 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm upto 5.00 sqm) sqm 5617.0 9.2 Providing and fixing 30mm thick factory made solid panel prelaminated PVC internal door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for styles top, lock and bottom rails. M.S.frame shall have a coat of steel primers of approved make and manufacture.M.S. frame sqm 3908.0 113 9.201 9.201.1 24 to 25 mm thick plain solid PVC flush door shutter sqm 2250.0 9.201.2 28 to 30 mm thick plain solid PVC flush door shutter sqm 3229.0 114 9.202 9.202.1 1mm thick laminated sheet sqm 3693.0 9.202.2 0.12 mm thick laminated sheet sqm 3461.0 115 9.255 9.255.1 9 mm thick BWP grade commercial Sqm 841.0 plywood 9.255.2 12 mm thick BWP grade commercial Sqm 1064.0 plywood 9.255.3 18 mm thick BWP grade commercial Sqm 1169.0 plywood 9.255.4 25 mm thick BWP grade commercial Sqm 1366.0 plywood 116 9.256 9.256.1 25 mm outer dia & 300 mm long Each Set 984.0 9.256.2 32 mm outer dia & 450 mm long Each Set 1716.0 9.256.3 32 mm outer dia & 600 mm long Each Set 2041.0 117 9.257 9.196, 9.197, 9.198, 9.199) 118 9.258 9.258.1 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. sqm 1040.0 119 10.7 10.7.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area. sqm 747.0 10.7.2 Exceeding 16.80 sqm in area. sqm 782.0 120 10.11 10.11.1 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). kg 77.0 121 10.12 10.12.1 Profile B of 1.60mm thick single rebate of size 80mmx50mm 10.12.1.1 Fixing with adjustable lugs with split end tail to each jamb. meter 402.0 10.12.1.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 394.0 10.12.2 Profile C of 1.60mm thick single rebate of size 100mmx50mm 10.12.2.1 Fixing with adjustable lugs with split end tail to each jamb. meter 431.0 10.12.2.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 424.0 10.12.3 Profile E of 1.60mm thick double rebate of size 115mmx50mm 10.12.3.1 Fixing with adjustable lugs with split end tail to each jamb. meter 472.0 10.12.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 464.0 10.12.4 Profile B of 1.25mm thick single rebate of size 80mmx50mm 10.12.4.1 Fixing with adjustable lugs with split end tail to each jamb. meter 356.0 10.12.4.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 348.0 10.12.5 Profile C of 1.25mm thick single rebate of size 100mmx50mm 10.12.5.1 Fixing with adjustable lugs with split end tail to each jamb. meter 385.0 10.12.5.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 377.0 10.12.6 Profile E of 1.25mm thick double rebate of size 115mmx50mm 10.12.6.1 Fixing with adjustable lugs with split end tail to each jamb. meter 414.0 10.12.6.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 406.0 122 10.14 10.14.1 Hot finished welded type tubes kg 117.0 10.14.2 Hot finished seamless type tubes kg 123.0 10.14.3 Electric resistance or induction butt welded tubes. kg 142.0 10.15 Design, supply, fabrication, taransportion and erection of structural steel/mild steel built-up sections for steel building in column, rafter, truss, floor joist, wind bracings, tie beam, foundation bolts, fasteners etc. Including two coats ofEpoxy paint and one coat of primer. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code. kg 132.0 123 10.17 124 10.18 125 10.19 126 10.21 127 10.22 10.22.1 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. kg 101.0 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. kg 105.0 128 10.23 10.23.1 M.S. tube. kg 117.0 10.23.2 E.R.W. tubes. kg 132.0 129 10.25 130 10.26 10.26.1 Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4 mm aperture on both sides sqm 646.0 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. sqm 1334.0 131 10.27 10.27.1 With 4.0 mm thick glass panes sqm 792.0 10.27.2 With 5.50 mm thick glass panes sqm 873.0 10.27.3 With 1mm thick mild steel sheet i/c 10x10x1.6mm box beading. sqm 916.0 10.27.4 With 2mm thick fibre reinforced polymer (FRP) sheet i/c 10x10x1.6mm boxbeading. sqm 611.0 10.27.5 With 1mm thick Galvanised steel sheet i/c 10x10x1.6mm box beading. sqm 936.0 10.27.6 With 4mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 750.0 10.27.7 With 6mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 800.0 10.27.8 With 8mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 872.0 132 10.28 10.28.1 With 4.0 mm thick glass panes. sqm 259.0 10.28.2 With 5.5 mm thick glass panes. sqm 262.0 133 10.29 134 11.19 11.19.1 Makrana white second quality. sqm 3051.0 11.19.2 Raj Nagar plain. sqm 1381.0 11.19.3 Agaria White/Morgarh sqm 1882.0 11.19.4 Katni marble sqm 1555.0 11.19.5 Black Zebra. sqm 1315.0 11.19.6 Udaipur / Baroda green marble sqm 1649.0 11.19.7 Pink plain marble. sqm 1448.0 11.19.8 Jaisalmer Yellow sqm 1582.0 135 11.2 11.20.1 Makrana white second quality. sqm 3675.0 11.20.2 Raj Nagar plain. sqm 1932.0 11.20.3 Agaria White/Morgarh sqm 2455.0 11.20.4 Katni marble sqm 2113.0 11.20.5 Black Zebra. sqm 1863.0 11.20.6 Udaipur / Baroda green marble sqm 2211.0 11.20.7 Pink plain marble. sqm 2002.0 11.20.8 Jaisalmer Yellow sqm 2141.0 136 11.21 11.21.1 Makrana white second quality. sqm 3773.0 11.21.2 Raj Nagar plain. sqm 2737.0 11.21.3 Agaria White/Morgarh sqm 2553.0 11.21.4 Katni marble sqm 2219.0 11.21.5 Black Zebra. sqm 1961.0 11.21.6 Udaipur / Baroda green marble sqm 2309.0 11.21.7 Pink plain marble. sqm 2100.0 11.21.8 Jaisalmer Yellow sqm 2240.0 137 11.22 11.22.1 Raj Nagar plain/White Marble/Udaipur Green Marble /Zebra black sqm 1797.0 11.22.2 Granite fine grained dark crystal of other colours and various patterns sqm 2356.0 11.22.3 Granite coarse grained light black/ light red/white with crystal of other colours and various patterns Sqm 2113.0 11.22.4 Granite grey/pink/brown with various patterns Sqm 1808.0 11.22.5 Cuddpah stone sqm 1279.0 138 11.23 139 11.24 140 11.25 141 11.29 11.29.1 Area of slab over 0.50 sqm 11.29.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2919.0 11.29.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2675.0 11.29.1.3 Gray/Pink/Brown or equivalent with various patterns sqm 2370.0 11.29.2 Area of slab upto 0.50 sqm 11.29.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2705.0 11.29.2.2 Coarse grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2486.0 11.29.2.3 Gray/Pink/Brown or equivalent with various patterns sqm 2212.0 142 11.3 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2642.0 11.30.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2422.0 11.30.1.3 Gray/Pink/Brown or equivalent with various patterns sqm 2153.0 11.30.2 Area of slab upto 0.50 sqm 11.30.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2455.0 11.30.2.2 Coarsegrained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2258.0 11.30.2.3 Gray/Pink/Brown or equivalent with various patterns sqm 2011.0 patterns 143 11.32 144 11.33 11.33.1 Flamed Finish Granite sqm 2542.0 11.33.2 Leather Finish Granite sqm 2809.0 145 11.34 146 11.36 Note: - Deduction shall be made for not mirror polishing according to item no 11.43 147 11.37 148 11.38 11.38.1 10-12 mm thick sqm 1177.0 11.38.2 20 mm thick sqm 1231.0 149 11.39 150 11.4 11.40.1 Marble work meter 164.0 11.40.2 Granite work. meter 269.0 151 11.41 152 11.42 153 11.43 154 11.44 11.44.1 Red sand stone sqm 578.0 11.44.2 White sand stone sqm 578.0 11.44.3 Grey lime stone sqm 578.0 11.44.4 Kota stone sqm 678.0 155 11.47 156 11.48 157 11.49 158 11.52 159 11.53 160 11.54 161 11.55 162 11.56 163 12.63 11.63.1 Fastener with threaded dia 6 mm. each 25.0 11.63.2 Fastener with threaded dia 10 mm. each 29.0 11.63.3 Fastener with threaded dia 12 mm. each 46.0 164 11.66 165 11.72 proper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction byusing plate vibrator, filling the joints with sand and cutting of paver blocks as per required sizeand pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in-Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade sqm 805.0 11.72.2 60 mm thick C.C. paver block of M-35 grade sqm 680.0 11.72.3 60 mm thick C.C. paver block of M-30 grade sqm 605.0 166 11.75 including fixing of granite stone door frame with epoxy resin based adhesive including secured to the backing by means of cramps, drilling of hole with rawl plugs and screws 75mm long cleaning etc. complete. Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, towerboltetc complete at all levels as per instruction of Engineer-in-Charge. 11.75.1 Granite Door frame for 100mm thick wall Thickness. metre 1010.0 11.75.2 Granite Door frame for 200mm thick wall Thickness. metre 1512.0 167 11.76 11.76.1 Plain ivory light shade sqm 950.0 Size 600X600mm thickness 9-10mm 11.76.2 Dark shade (terracotta) sqm 1033.0 Size 600X600mm thickness 9-10mm 168 11.77 11. 77.1 Plain ivory light shade sqm 940.0 Size 600X600mm thickness 9-10mm 11. 77.2 Dark shade (terracotta) sqm 1022.0 Size 600X600mm thickness 9-10mm 169 11.8 11.80.1 In light colour and shades as ivory, beige blanco, grey etc. 11.80.1.1 (a) Size 300X300 mm thickness 9-10 mm sqm 934.0 11.80.1.2 (b) Size 600X600mm thickness 9-10mm sqm 1206.0 11.80.1.3 (c) Size 600X600 mm thickness 11-12mm (to be used heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) sqm 1349.0 11.80.2 In dark colour and shade etc. 11.80.2.1 (a) Size 300X300 mm thickness 9-10 mm sqm 946.0 11.80.2.2 (b) Size 600X600mm thickness 9-10mm sqm 1340.0 11.80.2.3 (c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) sqm 1546.0 170 11.81 11. 81.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 81.1.1 (a) Size 300X300 mm thickness 9-10 mm sqm 923.0 11. 81.1.2 (b) Size 600X600mm thickness 9-10mm sqm 1196.0 11. 81.2 In dark colour and shades etc. 11. 81.2.1 (a) Size 300X300 mm thickness 9-10 mm sqm 935.0 11. 81.2.2 (b) Size 600X600mm thickness 9-10mm sqm 1329.0 171 11.82 11. 82.1 For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) 11. 82.1.1 Size 600X600 mm thickness 9-10 mm sqm 1140.0 11. 82.1.2 Size 800X800mm thickness 9-10 mm sqm 1261.0 11. 82.1.3 Size 800X1600mm thickness 9-10 mm sqm 1489.0 11. 82.1.4 Size 1000X1000mm thickness 9-10 mm sqm 1388.0 11. 82.1.5 Size 600X1200 mm thickness 9-10 mm sqm 1235.0 11. 82.1.6 Size 800X1200 mm thickness 9-10 mm sqm 1450.0 11. 82.1.7 Size 1200X1200 mm thickness 9-10 mm sqm 1596.0 11. 82.1.8 Size 1200X1800mm thickness 9-10 mm sqm 1715.0 11. 82.1.9 Size 1200X2400 mm thickness 9-10 mm sqm 2403.0 172 11.83 11. 83.1 For skirting, riser, dado and wall lining etc.glossy/ rustic /stain/mattfinished in all colours and shades 11. 83.1.1 Size 300X600 mm thickness 9-10 mm sqm 1048.0 11. 83.1.2 Size 600X600 mm thickness 9-10 mm sqm 1129.0 11. 83.1.3 Size 800X800mm thickness 11-12mm sqm 1250.0 11. 83.1.4 Size 600X1200 mm thickness 11-12mm sqm 1224.0 11. 83.1.5 Size 800X1200 mm thickness 11-12mm sqm 1440.0 173 11.84 11. 84.1 Area of tiles not less 0.18 sqm 11. 84.1.1 Fine granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter sqm 2296.0 11. 84.1.2 Course granite light Black/light Red/ off White with crystals of other colors and various patterns sqm 2113.0 11. 84.1.3 Gray/Pink/Brown with various patterns sqm 1879.0 174 11.85 11. 85.1 Area of tiles not less 0.18 sqm 11. 85.1.1 Fine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter sqm 1775.0 11. 85.1.2 Coarse grained granite light Black/light Red/ off White with crystals of other colors and various patterns sqm 1610.0 11. 85.1.3 Gray/Pink/Brown with various patterns sqm 1404.0 175 11.97 Size 800X1600 mm thickness 8-9 mm Sqm 1778.0 176 11.102 177 11.103 178 12.4 12.4.1 0.80mm thick with zinc coating not less than 275gm/m² meter 500.0 12.4.2 0.63mm thick with zinc coating not less than 275gm/m² meter 431.0 179 12.7 12.7.1 0.80mm thick with zinc coating not less than 275gm/m² meter 459.0 12.7.2 0.63mm thick with zinc coating not less than 275gm/m² meter 402.0 180 12.12 12.12.1 Corrugated serrated adjustable ridges meter 367.0 12.12.2 Plain wing adjustable ridges meter 311.0 12.12.3 Close fitting adjustable ridges meter 420.0 12.12.4 Unserrated adjustable hips meter 506.0 181 12.13 12.13.1 Corrugated apron pieces meter 340.0 12.13.2 Eaves filler pieces meter 232.0 12.13.3 North light curves meter 500.0 12.13.4 ventilator curves meter 622.0 12.13.5 Barge boards meter 623.0 12.13.6 Ridge finials pair 229.0 12.13.7 Special north light curves each 753.0 12.13.8 S type louvers meter 418.0 182 12.14 183 12.15 primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 184 12.16 12.16.1 Ridges plain (500 - 600mm). meter 320.0 12.16.2 Flashings/ Aprons.( Upto 600 mm) meter 284.0 12.16.3 North light curves. meter 341.0 12.16.4 Barge board (Upto 300 mm) meter 274.0 12.16.5 Crimp curve sqm 315.0 12.16.6 Gutter. (600 mm over all girth) meter 781.0 185 12.17 12.17.1 2mm thick corrugated (2.5 or 4.2 or 6) or step-down (2or 3or 6) as specified. sqm 1031.0 12.17.2 2mm thick flat. sqm 955.0 186 12.23 187 12.24 188 12.26 189 12.27 190 12.32 12.32.1 75 mm diameter (minimum wall thickness 1.8mm) metre 136.0 12.32.2 110 mm diameter (minimum wall thickness 2.2mm) metre 238.0 191 12.33 12.33.1 Coupler 12.33.1.1 75 mm (minimum wall thickness 1.8mm) each 67.0 12.33.1.2 110 mm (minimum wall thickness 2.2mm) each 102.0 12.33.2 Single push fit Coupler : 12.33.2.1 75 mm (minimum wall thickness 1.8mm) each 121.0 12.33.2.2 110 mm (minimum wall thickness 2.2mm) each 94.0 12.33.3 Single tee with door 12.33.3.1 75x75x75 mm (minimum wall thickness 1.8mm) each 106.0 12.33.3.2 110x110x110 mm (minimum wall thickness 2.2mm) each 176.0 12.33.4 Single tee without door 12.33.4.1 75x75x75 mm (minimum wall thickness 1.8mm) each 106.0 12.33.4.2 110x110x110 mm (minimum wall thickness 2.2mm) each 163.0 12.33.5 Bend 87.5° 12.33.5.1 75 mm bend (minimum wall thickness 1.8mm) each 78.0 12.33.5.2 110 mm bend (minimum wall thickness 2.2mm) each 112.0 12.33.6 Shoe (Plain) 12.33.6.1 75 mm Shoe (minimum wall thickness 1.8mm) each 69.0 12.33.6.2 110 mm Shoe (minimum wall thickness 2.2mm) each 99.0 192 12.34 12.34.1 75 mm (minimum wall thickness 1.8mm) each 97.0 12.34.2 110 mm (minimum wall thickness 2.2mm) each 114.0 hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in adirection perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.58.1 10mm thick plaster of Paris (gypsum anhydrous) sheet 10mm thick pop board. 12.58.1.1 Flat surfaces sqm 676.0 12.58.1.2 Curved surfaces sqm 748.0 12.58.1.3 Sunk or raised mouldings sqm 175.0 12.58.1.4 Extra for providing in the plaster of Paris (Gypsum anhydrous) ceiling above 5 metre height from floor level. sqm per meter height 59.0 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.1 Plain board conforming to IS: 2095- Part I: 2011 (Board with BIS certification marks). sqm 750.0 12.58.2.2 Fire resistant Glass ReinforcedGypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) sqm 866.0 12.58.2.3 12.5mm thick moisture resistant gypsum plasterboards Moistbloc as per BS EN 520 confirming to water absorption class H1 with total water absorption < 5%, Green Pro certified by CII sqm 920.0 12.58.2.4 Fully Perforated Gypsum Plaster Board having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturersspecification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. sqm 1277.0 12.58.3 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured throughautoclaving process. sqm 1150.0 193 13.1 13.1.1 1:4 (1 cement : 4 sand) sqm 173.0 13.1.2 1:6 (1 cement : 6 sand) sqm 160.0 194 13.2 13.2.1 1:4 (1 cement : 4 sand) sqm 184.0 13.2.2 1:6 (1 cement : 6 sand) sqm 168.0 195 13.3 13.3.1 1:4 (1 cement : 4 sand) sqm 245.0 13.3.2 1:6 (1 cement : 6 sand) sqm 225.0 196 13.4 13.4.1 1:3 (1 cement : 3 sand) sqm 210.0 13.4.2 1:4 (1 cement : 4 sand) sqm 203.0 197 13.5 13.5.1 1:3 (1 cement : 3 sand) sqm 236.0 13.5.2 1:4 (1 cement : 4 sand) sqm 220.0 198 13.13 199 13.14 200 13.15 13.15.1 Exterior walls of height more than 10 m from ground for every additional height of 3 m or part thereof sqm 34.0 13.15.2 Interior walls of height more than 6 m from floor level for every additional height of 3 m or part thereof sqm 22.0 201 13.16 13.16.1 In one coat sqm 11.0 13.16.2 In two coats sqm 18.0 202 13.17 13.17.1 In one coat sqm 158.0 13.17.2 In two coats sqm 260.0 203 13.18 13.18.1 Spherical ceiling sqm 42.0 13.18.2 Groined ceiling sqm 47.0 13.18.3 Flewing soffits sqm 28.0 204 13.38 205 13.39 13.39.1 Providing and applying plaster of paris punning of 10 mm average thickness over plastered surface to prepare the surface even and smooth complete. sqm 130.0 13.39.2 Extra for making 12mm flute grove with 6 mm depth to prepare the surface even and smooth complete. metre 70.0 206 13.41 207 13.43 208 13.44 209 13.45 210 13.46 211 13.47 13.47.1 One coat. sqm 20.0 13.47.2 Two coats. sqm 32.0 212 13.48 13.48.1 One coat. sqm 37.0 13.48.2 Two coats. sqm 56.0 213 13.49 214 13.51 215 13.52 216 13.53 217 13.54 218 13.54.1 219 13.54.2 220 13.54.3 221 13.55 13.55.1 One coat sqm 63.0 13.55.2 Two coats sqm 101.0 222 13.64 223 13.65 224 13.66 13.66.1 One coat. sqm 35.0 13.66.2 Two coats. sqm 53.0 225 13.68 226 13.71 227 13.77 228 13.8 13.80.1 0.8-1.2mm thickness sqm 368.0 13.80.2 2.0-2.5mm thickness sqm 338.0 229 13.81 effective for 90 Days(03 Months) . 230 13.103 Note:- Applicable to item No. 13.1 to item No. 13.10 231 13.105 13.105.1 Standard pattern and design wallpaper Sqm 615.0 13.105.2 3D pattern and design wallpaper Sqm 750.0 13.105.3 Customize design wallpaper Sqm 1145.0 232 14.5 14.5.1 Float glass panes of thickness 4 mm sqm 679.0 14.5.2 Float glass panes of thickness 5.5 mm sqm 759.0 233 14.6 14.6.1 Float glass panes of thickness 4 mm sqm 801.0 14.6.2 Float glass panes of thickness 5.5 mm sqm 882.0 234 14.7 14.7.1 Float glass panes of thickness 4 mm sqm 697.0 14.7.2 Float glass panes of thickness 5.5 mm sqm 778.0 235 14.8 14.8.1 2nd class teak wood fillets meter 30.0 14.8.2 Haldu/Bija/Kail wood fillets. meter 26.0 236 14.11 237 14.24 238 14.27 239 14.28 240 14.29 241 14.31 242 14.36 243 14.37 244 14.38 245 14.39 246 14.48 247 14.49 14.49.1 Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 liters/10 sqm complete including cost of Priming coat. sqm 42.0 14.49.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. sqm 30.0 248 14.51 14.51.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). sqm 87.0 14.51.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm). sqm 52.0 249 14.52 14.52.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. sqm 65.0 14.52.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm). sqm 41.0 250 14.53 14.53.1 One or more coats applied on walls @ 0.85 ltr/10 sqm. sqm 58.0 251 14.62 14.62.1 (one or more coats) sqm 9.0 14.62.2 (two or more coats) sqm 11.0 252 15.2 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). cum 578.0 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). cum 356.0 253 15.6 15.6.1 In lime mortar with old mughal bricks. cum 421.0 15.6.2 In lime mortar. cum 202.0 15.6.3 In cement mortar. cum 487.0 254 15.7 15.7.1 From brick work in lime mortar. 1000 nos 1254.0 15.7.2 From brick work in cement mortar. 1000 nos 1560.0 255 15.8 15.8.1 In lime mortar. cum 275.0 15.8.2 In cement mortar. cum 582.0 256 15.13 257 15.14 15.14.1 Of area 3 sq. metres and below. each 85.0 15.14.2 Of area beyond 3 sq. metres. each 117.0 258 15.15 15.15.1 Of area 3 sq. metres and below. each 33.0 15.15.2 Of area beyond 3 sq. metres. each 44.0 259 15.47 260 15.48 261 15.49 262 15.51 15.51.1 Rectangular manhole 90x80 cm and 45 cm deep each 611.0 15.51.2 Rectangular manhole 120x90 cm and 90 cm deep. each 1069.0 15.51.3 Rectangular arch type manhole 140x90cm and 2.45m deep. each 2023.0 15.51.4 Circular manhole 122 cm diameter and 1.68 m deep each 1553.0 263 15.52 15.52.1 Rectangular manhole 90x80 cm and beyond 45 cm depth. each 486.0 15.52.2 Rectangular manhole 120x90 cm and beyond 90 cm depth. each 579.0 15.52.3 Rectangular arch type manhole 140x90 cm and beyond 2.45m deep (upto 4.25 m depth). each 468.0 15.52.4 Circular manhole 122 cm diameter and beyond 1.68 m deep (upto 2.29 m depth). each 322.0 264 15.64 265 17.1 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. each 2995.0 266 17.2 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid. each 3036.0 17.2.2 W.C. pan with ISI marked black solid plastic seat and lid. each 3013.0 267 17.3 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. each 4613.0 17.3.2 W.C. pan with ISI marked black solid plastic seat and lid. each 4590.0 268 17.11 17.11.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. each 2187.0 17.11.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar tap. each 1938.0 17.11.4 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. each 1664.0 17.11.5 White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap. each 1775.0 269 17.12 270 17.14 17.14.1 Kitchen sink with drain board 17.14.1.1 510x1040 mm bowl depth 250mm. each 8074.0 17.14.1.2 510x1040 mm bowl depth 225mm. each 7609.0 17.14.1.3 510x1040 mm bowl depth 200mm. each 7493.0 17.14.1.4 510x1040 mm bowl depth 178mm. each 5286.0 17.14.2 Kitchen sink without drain board 17.14.2.1 610x510 mm bowl depth 200 mm. each 4583.0 17.14.2.2 610x460 mm bowl depth 200 mm. each 4351.0 17.14.2.3 470x420 mm bowl depth 178 mm. each 3422.0 271 17.22 17.22.1 White each 945.0 17.22.2 coloured each 1037.0 272 17.24 17.24.1 White each 456.0 17.24.2 Black each 433.0 17.24.3 Coloured (other than black and white) each 688.0 273 17.25 274 17.6 17.60.1 75 mm each 33.0 17.60.2 110 mm each 50.0 275 17.61 276 17.64 17.64.1 Semi rigid pipe 17.64.1.1 32 mm dia each 87.0 17.64.1.2 40 mm dia each 98.0 17.64.2 Flexible pipe (only in residential & complaxes) 17.64.2.1 32 mm dia each 87.0 17.64.2.2 40 mm dia each 98.0 277 17.65 278 17.67 279 17.67 17.68.1 Circular shape 450mm dia. each 806.0 17.68.2 Rectangular shape 453x357mm each 642.0 17.68.3 Oval shape 450x350mm (outer dimensions) each 697.0 17.68.4 Rectangular shape 1500x450 mm each 1311.0 280 17.69 281 17.7 17.70.1 C.P. brass each 340.0 17.70.2 Vitreous china each 324.0 282 17.74 283 17.75 284 17.76 285 18.6 18.6.1 Internal work - Exposed on wall 18.6.1.1 15 mm nominal outer dia .Pipes metre 129.0 18.6.1.2 20 mm nominal outer dia .Pipes metre 153.0 18.6.1.3 25 mm nominal outer dia .Pipes metre 177.0 18.6.1.4 32 mm nominal outer dia .Pipes metre 254.0 18.6.1.5 40 mm nominal outer dia .Pipes metre 354.0 18.6.1.6 50 mm nominal outer dia .Pipes metre 528.0 18.6.2 Concealed work including cutting chases and making good the walls etc. 18.6.2.1 15 mm nominal outer dia .Pipes metre 207.0 18.6.2.2 20 mm nominal outer dia .Pipes metre 234.0 18.6.2.3 25 mm nominal outer dia .Pipes metre 288.0 18.6.2.4 32 mm nominal outer dia .Pipes metre 360.0 286 18.7 External Work 18.7.1 15 mm nominal outer dia .Pipes metre 122.0 18.7.2 20 mm nominal outer dia .Pipes metre 141.0 18.7.3 25 mm nominal outer dia .Pipes metre 185.0 18.7.4 32 mm nominal outer dia .Pipes metre 238.0 18.7.5 40 mm nominal outer dia .Pipes metre 324.0 18.7.6 50 mm nominal outer dia .Pipes metre 498.0 18.7.7 62.50 mm nominal inner dia .Pipes. metre 1429.0 18.7.8 75 mm nominal inner dia .Pipes. metre 2018.0 18.7.9 100mm nominal inner dia .Pipes. metre 2791.0 18.7.10 150 mm nominal inner dia .Pipes. metre 3358.0 287 18.13 18.13.1 25 mm nominal bore each 428.0 18.13.2 32 mm nominal bore. each 500.0 18.13.3 40 mm nominal bore each 584.0 18.13.4 50 mm nominal bore each 749.0 288 18.14 18.14.1 15 mm nominal bore each 316.0 18.14.2 20 mm nominal bore each 431.0 18.14.3 25 mm nominal bore each 499.0 289 18.17 18.17.1 30 cm length 18.17.1.1 15 mm nominal bore each 88.0 18.17.1.2 20 mm nominal bore each 129.0 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore each 149.0 18.17.2.2 20 mm nominal bore each 184.0 290 18.18 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. each 916.0 18.18.2 With well burnt flyash bricks of 50 kg/sqm compressive strength. each 870.0 291 18.28 292 18.29 18.29.1 15 mm nominal bore each 306.0 18.29.2 20 mm nominal bore each 338.0 293 18.3 18.30.1 15 mm nominal bore each 318.0 18.30.2 20 mm nominal bore each 344.0 294 18.31 295 18.32 296 18.33 297 18.34 298 18.35 299 18.36 300 18.37 301 18.38 302 18.39 303 18.41 304 18.42 305 18.43 18.43.1 100 mm diameter each 806.0 18.43.2 150 mm diameter each 922.0 18.43.3 200 mm diameter each 1336.0 306 18.64 307 18.65 308 18.67 309 18.68 18.68.1 300 mm long each 450.0 18.68.2 600 mm long each 650.0 310 19.4 19.4.1 110 mm diameter OD (min. wall thickness 3.2mm) metre 234.0 19.4.2 160 mm diameter OD (min. wall thickness 4.0 mm) metre 477.0 19.4.3 200 mm diameter OD (min. wall thickness 4.9 mm) metre 751.0 19.4.4 250 mm diameter OD (min. wall thickness 6.2mm) metre 972.0 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) metre 1232.0 311 19.5 19.5.1 110 mm diameter PVC. pipe metre 576.0 19.5.2 160 mm diameter PVC. pipe metre 704.0 19.5.3 200 mm diameter PVC. pipe metre 821.0 19.5.4 250 mm diameter PVC. pipe metre 949.0 19.5.5 300 mm diameter PVC pipe metre 1078.0 312 19.6 19.6.1 110 mm diameter PVC. pipe metre 274.0 19.6.2 160 mm diameter PVC. pipe metre 444.0 19.6.3 200 mm diameter PVC. pipe metre 521.0 19.6.4 250 mm diameter PVC. Pipe metre 607.0 19.6.5 300 mm diameter PVC pipe metre 700.0 313 19.7 19.7.1 100x100 mm size P type 19.7.1.1 With well burnt bricks each 1764.0 19.7.1.2 With Sewer bricks conforming to IS : 4885 each 1668.0 19.7.2 150 x 100 mm size P type. 19.7.2.1 With well burnt bricks each 1803.0 19.7.2.2 With sewer bricks conforming to IS : 4885 each 1707.0 19.7.3 180x150 mm size P type 19.7.3.1 With well burnt bricks each 1913.0 19.7.3.2 With Sewer bricks conforming to IS : 4885 each 1818.0 314 19.9 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks each 7997.0 19.9.1.2 With Sewer bricks conforming to IS : 4885 each 7747.0 19.9.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight offrame 58 kg) : 19.9.2.1 With well burnt bricks each 18086.0 19.9.2.2 With Sewer bricks conforming to IS : 4885 each 17402.0 19.9.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) 19.9.3.1 With well burnt bricks each 21816.0 19.9.3.2 With Sewer bricks conforming to IS : 4885 each 21228.0 315 19.1 19.10.1 Size 90x80 cm 19.10.1.1 With well burnt bricks metre 6176.0 19.10.1.2 With Sewer bricks conforming to IS : 4885 metre 5448.0 19.10.2 Size 120x90 cm 19.10.2.1 With well burnt bricks metre 7380.0 19.10.2.2 With Sewer bricks conforming to IS : 4885 metre 6512.0 316 19.12 19.12.1 With well burnt bricks metre 5257.0 19.12.2 With Sewer bricks conforming IS : 4885 metre 4648.0 317 21.1 21.1.1 For fixed portion. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) kg 378.0 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 416.0 21.1.1.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron) kg 426.0 21.1.2 For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings whereverrequired including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) kg 446.0 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 484.0 21.1.2.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron) kg 494.0 21.1.3 Deduct for not providing EDPM rubber/neoprene gasket all around. kg 80.0 318 21.2 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. sqm 802.0 21.2.2 Pre-laminated particle board with decorative lamination on both sides. sqm 907.0 319 21.3 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) sqm 774.0 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than sqm 948.0 12.50 kg/sqm ) 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). sqm 1182.0 320 21.5 21.5.1 With stainless steel cover plate - minimum 1.25 mm thickness each 1890.0 21.5.2 With brass cover plate - minimum 1.25 mm thickness. each 2072.0 321 21.16 21.16.1 Anodized (AC15 ) aluminium each 62.0 21.16.2 Powder coated minimum thickness 50 micron aluminium each 65.0 21.16.3 Polyester powder coated minimum thickness 50 micron aluminium. each 69.0 322 21.17 323 21.18 324 21.19 325 21.21 326 21.22 327 21.23 328 21.24 329 21.32 330 22.6 a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. 331 22.14 22.14.1 Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cum 6569.0 22.14.2 Cement mortar 1:3 (1 cement : 3 sand) cum 9308.0 22.14.3 Cement mortar 1:4 (1cement : 4 sand) cum 8437.0 332 25.1 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440X575X250mm With integral foot rests. (Premium Range) each 4726.0 25.1.2 White Vitreous china Anti germ Fluoro-Polymer coated Orissa pattern W. C. pan of size 410X515X255 mm with integral foot rests.(Premium Range) each 4392.0 333 25.2 25.2.1 Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan Size 360X545X395 with solid poly propelyne made soft closing seat cover (Premium Range) each 9788.0 25.2.2 Anti-germ Fluoro-Polymer Coated Water Closet European type W. C. pan size 360X475X395 mm with solid poly propelyne made soft closing seat cover (Premium Range) each 8742.0 334 25.3 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380X520X375 mm with solid poly propelyne made soft closing seat cover (Premium Range) each 26412.0 25.3.2 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 390X570X365 mm with solid poly propelyne made, soft closing seat cover (Premium Range) each 23559.0 25.3.3 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500 x 330mm with solid poly propelyne made, soft closing seat cover (Premium Range) each 21099.0 25.3.4 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500 x 330mm or greater size with solid poly propelyne made, soft closing seat cover (Premium Range) each 18838.0 335 25.4 25.4.1 Anti germ Fluoro-Polymer Coated couple water closet Size 420X710X810mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 28103.0 25.4.2 Anti germ Fluoro-Polymer Coated couple water closet Size 380X610X805mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 19275.0 25.4.3 Anti germ Fluoro-Polymer Coated couple water closet Size 370 x 640 x 760mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 18952.0 25.4.4 Anti germ Fluoro-Polymer Coated couple water closet Size 375X650X800 mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 18023.0 336 25.5 25.5.1 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) Each 34317.0 25.5.2 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 25954.0 25.5.3 Anti germ Fluoro-Polymer Coated Single PieceW.C. Pan Size 385X720X710mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 22237.0 25.5.4 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 19450.0 337 25.6 25.6.1 Anti germ Fluoro-Polymer Coated extended wall hung type couple closet Size 380X650X730mm with solid poly propelyne made soft closing seat cover (Premium Range) each 13365.0 25.6.2 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet Size 375X360X750mm along with dual flushing cistern flushing capacity 3 & 6 litre. (Premium Range) each 10670.0 338 25.7 25.7.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595X435X185 mm with basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) each 16581.0 339 25.8 25.8.1 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570x415x200mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system with square wall flance & spout complete (decol technology). (Premium Range) each 14543.0 25.8.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570X820X195mm with 15 mm C. P. Table Top pressmatic Pillar cock auto closing system (decol technology). (Premium Range) each 13614.0 340 25.9 25.9.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range) each 15591.0 25.9.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 600x400x185mm with 15 mm C. P. wall mounted single lever concealed basin mixture. (Premium Range) each 14940.0 341 25.1 25.10.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185mm with Table mounted single lever Tall boy basin mixture, (cartridge size 32mm.) (Premium Range) each 18585.0 25.10.2 White vitreous china type Anti germ fluoro- polymer coated counter top wash basin Size 530x420x140mm with tall boy basin mixture, (cartridge size 32 mm). (Premium Range) each 16785.0 342 25.11 25.11.1 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm. (Premium Range) each 14544.0 25.11.2 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal size 475X315X715 mm top inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) with 15mm Brass made Pressmatic auto closing open urinal flush valve with wall flange (Decol technology, 400000 operation warranted) complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : each 13336.0 25.11.3 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal back inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) Size 385X325X635 mm with Concealed sensotronic flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : URS-WHT-13253N & PRS-CHR-073 each 10641.0 343 25.12 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve battery & electrical oprated type (9V transformer) for urinal complete set with installation box with control cock. (Premium Range) each 23927.0 25.12.2 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385x325x635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range) each 20025.0 344 25.13 25.13.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 480 X 300X740 mm with 15mm Brass made pressmatic auto closing concealed urinal flush valve with wall flange (Decol technology, 400000 operation warranted). (Premium Range) each 18491.0 345 25.14 346 25.14.1 25.14.2 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated Urinal size 475x315x715 mm (Inbuilt spreaders, bottle trap and ceramic waste coupling) with inbuilt sensor battery & electrical oprated type (9V transformer) for flushing. (Premium Range) each 22998.0 347 25.15 348 25.16 349 25.17 350 25.18 351 25.19 352 25.21 353 25.22 354 25.23 355 25.24 356 25.25 357 25.26 358 25.27 359 25.28 360 25.29 361 25.31 362 25.32 363 25.33 364 25.34 365 25.35 366 25.36 367 25.37 368 25.38 369 25.39 370 25.41 371 25.42 372 25.43 373 25.44 374 25.45 375 25.46 376 25.47 377 25.48 378 25.49 379 25.51 380 25.52 381 25.53 382 25.54 383 25.55 384 25.56 385 25.57 386 25.58 387 25.59 388 25.61 389 25.62 390 25.63 vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, C. P. brass single lever basin mixer, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.63.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) each 14729.0 25.63.2 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 570x470x190 mm. (Premium Range) each 15100.0 25.63.3 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 495x400x365 mm. (Premium Range) each 18490.0 391 25.64 25.64.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) each 10617.0 Note- Schedule of items includes all the items required for maintainance of buildings regarding A/R, S/R MOW, Deposit & Other Works as per SCHEDULE OF RATES FOR BUILDING WORKS inforce from 01/01/2024, issued by Project Director, Public Works Department (PIU) M.P. Bhopal. Sub Engineer Sub Divisional OfficerSurvey Sub Division.P.W.D. Bhopal Executive EngineerMaintanance Division No.2P.W.D. Bhopal
Contract Date: Apr 23, 2026 Contract Value : 21.93 Lakh
Government Departments No of Bidders 5
Madhya Pradesh View Result →
16.
Rural Development #11306391 AOC
Tender For Jambli Gram Panchayat Office Remaining Work. Tal.Bhor- 1 Excavation for foundation in earth,soil of all types,sand,gravel and soft murum, including removing the excavated material up to a distance of 50m.beyond the building area and stacking and spreading as directed,dewatering,preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 2 Excavation for foundation in hard murum including removing the excavated material upto distanceof50metresbeyondthebuildingareaandstackingandspreadingas directed,dewatering, preparing the bed for the foundation and necessary back filling,ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50m) By Manual Means 3 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 4 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (Non SCADA Item) 5 Fillingin plinth and floors with approved excavatedmaterialin15cm.to20cm.Layers including watering and compacting etc. complete. 6 Filling in plinth and floors with contractorsmaterial/brought from outside and approved byEngineer inchargein layers of 15 cmto 20 cm including watering andcompactionetc. complete. 7 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Concrete Non Scada) 8 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 9 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 10 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 11 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete 12 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 13 Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. 14 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 15 Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. 16 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete 17 Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metreasperdrawingincludingfixturesnecessaryweldingandpaintingwith onecoatof anticorrosive paint and two coats of oil painting complete. 18 Providing and fixing frame with/without ventilator of size as specified with Country non teakwood for doors and windows including chamfering,rounding,rebating,iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. 19 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings,with brassmortise lock,chromium plated handles on both sides, and finishing with French Polish etc. complete. 20 Providing and fixing collapsible steel gate in one/twoleaves with hotrolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12mmwithrollerwheelsconfirmingtogradeF.G.150fitted withsnapheadedrivets of minimum size 6 mm max. spacing of vertical channels be 100mmenclosedgatepositionandclear space of 150 mm between two sets of crossingswithholdfasts,stoppers,spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). 21 Providing and fixing in position powder coated aluminium louvered windows / ventilator ofvarious sizes with powder coating as per detailed drawing and specifications including aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheet glasslouvers,of approved quality etc. complete. 22 Providing andfixing inposition(asper1868/1982)Aluminium sliding windowof three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeof bearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre. Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Running metre. andhandleandtopsection40x18x1.25mm atweight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fittedin vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainless steeljailwithall required screws and nuts etc, complete. With powder coating without box 23 Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. 24 Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete 25 Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. 26 Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 27 Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. 28 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 29 Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaningoil,grease,dirtandotherforeignmatterandsandpaperingasrequiredetc.complete. 30 Providingandapplyingpearl/lusterfinishpaintofapprovedcolourandshadetothe existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc.complete. 31 Providing and applying two coats of exteriorweather shield paint of approved manufactureand of approved colour to the plastered surfaces including cleaning,preparing the plastersurface,applyingprimercoat,scaffoldingifnecessary,and watering the surface for two days etccomplete. NOTE: ForItem One Number 15 to 18 prior approval of Superintending Engineer will be necessary 32 Providing and fixing board displaying information, such as Name of work, Tender cost,Name of Contractor, Work completion and liability period etc, having rectangular shapeof 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted withone coat of Zinc chromate stoving primer and two coats of enamel paint on front side andgrey stove enamel on back side and border / messages / symbols etc. with approved colourshade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly crossbraced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angleiron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black andwhite bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling,transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge 33 BASIC TEST OF AGGREGATE. 1)Water Absorption, Specific Gravity,Impact Value, Crushing Value. 34 CONCRETE. 1)Compressive Strength OF C.C. Cube (Set of 3 cubes). 35 MORTOR. 1)Compressive Strength.( Set of 3 Cubes) 36 STEEL BAR TESTING.1)Upto 16 mm (Set of 3 Bars) 37 Royalty For Natural Sand - Screened (for plaster work only) 38 Royalty For Soft Murum
Contract Date: Jun 17, 2026 Contract Value : 8.78 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
17.
Public Administrative Department #11306280 AOC
To carry out various remaining development works at Vitthal Tupe Sports Complex Hadapsar=-ITEM NO : 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means ( SSR Item No : 21.02 ) (PMC Bhavan ) Unique No (15202) Rate List Year (2024-2025) ITEM NO : 2 Transportation of material obtained from excavation including soil, rubble,bricks,RCC concrete, kerb stones, steel railing, iron pipes, channels etc. Obtained from excavation, dismantling, loading in a Truck of minimum 5 Cu M capacity or designed capacity and transporting within the municipal limits or any designated place, unloading, stacking or spreading of material etc. complete. ( SSR Item No : 2.39 ) (PMC ROAD ) Unique No (114) Rate List Year (2023-2024) ITEM NO : 3 Supplying hard murum/ kankar at the road site, including conveying and stacking complete. ( SSR Item No : 2.29a ) (PMC ROAD ) Unique No (103) Rate List Year (2023-2024) ITEM NO : 4 Spreading hard murum/ soft murrum/ gravel or kankar for side width complete ( SSR Item No : 2.30 ) (PMC ROAD ) Unique No (105) Rate List Year (2023-2024) ITEM NO : 5 Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. ( SSR Item No : 2.31 ) (PMC ROAD ) Unique No (106) Rate List Year (2023-2024) ITEM NO : 6 Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete. ( SSR Item No : 42.11 ) (PMC Bhavan ) Unique No (15863) Rate List Year (2024-2025) ITEM NO : 7 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. ( SSR Item No : 42.12 ) (PMC Bhavan ) Unique No (15864) Rate List Year (2024-2025) ITEM NO : 8 Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. N o t e : O n l y 8 5% r a t e i s p a y a b l e t i l l satisfactory hydraulic testing is given. The Bidder shall procure RCC pipes and chamber covers from following suppliers 1) M/S Sneh Precast 2) M/S Kalokhe pipes and precast industries 3) M/S Poona Concrete Company If bidder wish to supply RCC pipes and chamber covers other than above suppliers, then it is mandatory to take approval of supplier from concern department. Third party inspection of RCC pipes and chamber covers is mandatory and should be witnessed by EIL/IR CLASS/SGS. The cost of third party inspection should be borne by contractor. Class ‘NP-II 300 mm ( SSR Item No : 50.a vii ) (PMC Drainage ) Unique No (19058) Rate List Year (2024-2025) ITEM NO : 9 Providing and constructing on sewer line, B. B. masonry circular m a n h o l e w i t h c o n c e n t r i c cone 1.2 M dia. at bottom and 0.5 M dia. at top and upto a depth of 1.50 M with 23 cm. thick and 35cm thick brickwork for balanced depth in 230 X 100 X 75 mm brick masonry in CM 1:5 proportion plastering both inside and outside in CM 1:3 with cement finish, half round RCC pipe of required dia excluding excavation including PCC1:3:6 in bed 100 mm thick , haunches and channels in 1:2:4 proportion concrete, finishing channels in smooth rendering, providing 100 mm thick 1:2:4 coping on the top of the masonry & below frame including providing and fixing approved make and quality S.F.R.C. frame and cover of 56 cm dia. heavy duty 275 kg. etc. complete as directed by Engineerincharge. Note : The rate of this item isinclusive of hydraulic testing of chamber. Providing and constructing on sewer, B. B. masonry circular manhole with concentric cone (as per attached drawing no.1) ( SSR Item No : 56 ) (PMC Drainage ) Unique No (19206) Rate List Year (2024-2025) ITEM NO : 10 Providing & Applying External Textured Paint + Applying Waterproofing Coat as per below steps 1) Cleaning + crack filling 2) 1coat of Waterproofing Chemical 3) 1 Coat Apex Duracast CrossTex (2mm Thk) 4) 2 Coat of Professional Premium Exterior Emulsion Apex including claning and preparing the existing surface and scaffolding if necessary ( SSR Item No : 63.13 ) (PMC Bhavan ) Unique No (16702) Rate List Year (2024-2025) ITEM NO : 11 Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. ( SSR Item No : 32.34 ) (PMC Bhavan ) Unique No (15466) Rate List Year (2024-2025) ITEM NO : 12 Water bound distemper : Providing and applying water bound distemper along with primer coats including scaffolding if necessary, cleaning and preparing the surface etc. complete Recommended companies: Asian, neroleck, Dulex ( SSR Item No : 63.1 ) (PMC Bhavan ) Unique No (16691) Rate List Year (2024-2025) ITEM NO : 13 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. ( SSR Item No : 46.42 ) (PMC Bhavan ) Unique No (1547) Rate List Year (2023-2024) ITEM NO : 14 House keeping : Cleaning Of Passage by wet and dry method including swipping, water, phenol, room freshener, acid and chemical cleaning, scrubber machine, Colin for glass cleaning, material and labour, etc. complete. ( including all windows, doors, tables etc. present in passage for one time cleaning) ( SSR Item No : 78.19 ) (PMC Bhavan ) Unique No (17191) Rate List Year (2024-2025) ITEM NO : 15 Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. ( SSR Item No : 35.23 ) (PMC Bhavan ) Unique No (15573) Rate List Year (2024-2025) ITEM NO : 16 Building (Bd-V : Water supply and sanitory fittings)Upvc sanitary pipes all 20 mm dia ( SSR Item No : 49.V-346 ) (PMC Bhavan ) Unique No (2314) Rate List Year (2023-2024) ITEM NO : 17 Flat back urinal-providing and fixing flat back urinal without flushing tank but including bracket for fixing urinals,inlet pipe,32mm dia pvc flush pipe and stop tap ,filling the gaps with white cement etc complete ( SSR Item No : 61.04 ) (PMC Bhavan ) Unique No (16484) Rate List Year (2024-2025) ITEM NO : 18 Building (Bd-V : Water supply and sanitory fittings)Gun Metal stop tap with crutch wheel 20mm ( SSR Item No : 49.V-31 ) (PMC Bhavan ) Unique No (17702) Rate List Year (2024-2025) ITEM NO : 19 Building (Bd-V : Water supply and sanitory fittings)Shower rose chromium plated brass 10cm ( SSR Item No : 49.V-177 ) (PMC Bhavan ) Unique No (17848) Rate List Year (2024-2025) ITEM NO : 20 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. ( SSR Item No : 23.01 ) (PMC Bhavan ) Unique No (15297) Rate List Year (2024-2025) ITEM NO : 21 Providing and fixing colour coated Zincalume (R) AZ150 (min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon)coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center tocenter. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) with COLORBOND ( R ) steel quality super durable polyester paint ( SSR Item No : 38.34 ) (PMC Bhavan ) Unique No (1155) Rate List Year (2023-2024) ITEM NO : 22 Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant with scada as per approved mix design, admixtures, transporting to site, spreading, laying with skid vibrator,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. ( SSR Item No : 5.03 ) (PMC ROAD ) Item Spec : (MORTH 602) Unique No (175) Rate List Year (2023-2024) ITEM NO : 23 Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete ( SSR Item No : 40.6 ) (PMC Bhavan ) Unique No (15777) Rate List Year (2024-2025) ITEM NO : 24 Providing and fixing self supporting steel roofing system for a Godown or alike made up of structural grade steel sheet of 912 millimeter width ( tolerance +/- 2 millimeter ), moulded at site using mechanical press dies to the desired curve and shape to form 605 millimeter wide interlocking panels . The interlocking panels shall be pressed to close the seam forming water tight joints for a span of 15.30 meter having arch rise as 3.06 meter, arch length 17.75 meter. The base material made up of imported galvalume steel complying to ASTM A792 having base metal thickness of 0.80 millimeter ( tolerace + / - 0.02 millimeter ) with alloy coating AZ 150 and paint coating of regular modified polyster , top coat 25 micron and bottom coat 12 micron as per approved colour , including fixing hangers , clamps etc.as may be necessary of Proflex standard, including fixing sky light of millimeter thick polycarbonate sheet of size 2’ x 7’ and turbo ventilator of 24’’diameter to be installed at every 30 feet along the length of roof including finishing, testing and cleaning etc. complete. ( SSR Item No : 38.41 ) (PMC Bhavan ) Unique No (15662) Rate List Year (2024-2025) ITEM NO : 25 Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish ( SSR Item No : 33.36 ) (PMC Bhavan ) Unique No (15504) Rate List Year (2024-2025) ITEM NO : 26 Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) ( SSR Item No : 39.20 ) (PMC Bhavan ) Unique No (15694) Rate List Year (2024-2025) ITEM NO : 27 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track sect ion 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. ( SSR Item No : 39.37 ) (PMC Bhavan ) Unique No (15711) Rate List Year (2024-2025) ITEM NO : 28 Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade complete. Spec. Number : As directed by Engineer-in-charge. ( SSR Item No : 23.11 ) (PMC Bhavan ) Unique No (15306) Rate List Year (2024-2025) ITEM NO : 29 BITUMINOUS CONCRETE WITH SCADA:- Providing and laying bituminous concrete using crushed aggregates of grading II, premixed with bituminous binder @ 6% per cent by weight of total mix and filler, transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction for 50 mm compacted thickness with specified grade of Bitumen,Excluding prime / tack coat. For Bitumen of specified grade -- USING Batch mix type hot mix plant with SCADA, Sensor Paver with scada, vibratory roller with scada.with Stone Dust filler with Stone Dust filler. (VG-30 bulk bitumen rates are considered ) ( SSR Item No : 3.48 ) (PMC ROAD ) Unique No (627) Rate List Year (2024-2025) ITEM NO : 30 Stamped Concrete :- Thin overlay approximately 1/32 to 5/16 (thicker application may be nessecery in some situations) of stamped concrete overlays over M-20 concrete of 100 mm thicksurface, interior, applied smooth,textured or stamped in various patterns and designs using stamps and seamless texture skins, then antiqued, chemically stained or integrally colored and sealed with the appropriate coating. Systems sealers or protective top coats according to the job conditions and specifications. (including the cost of M-20 concrete of 100 mm thickness) ( SSR Item No : 1.10 ) (PMC ROAD ) Unique No (204) Rate List Year (2023-2024) ITEM NO : 31 Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete ( SSR Item No : 27.13 ) (PMC Bhavan ) Unique No (15381) Rate List Year (2024-2025) ITEM NO : 32 Providing rough cast cement plaster externally in two coats with coloured cement finish to concrete/ brick/ stone masonry surfaces in all positions with base coat 12 to 15 mm. thick in C.M. 1:4 using gray cement and rough cast treatment 12 mm thick in proportion of 1:1 1/2:3 using colour pigment including scaffolding and fourteen days curing etc. complete. ( SSR Item No : 32.13 ) (PMC Bhavan ) Unique No (15446) Rate List Year (2024-2025)
Contract Date: Jun 22, 2026 Contract Value : 49.64 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
18.
Educational and Research Institute #11303303 AOC
Bids Are invited for Furniture And Renovation Work Of Director Of Research Office Plywood 19Mm Bwr Md Table Storage Sides - 19Mm Bwr Grade Plywood 8X4 Ft Sheet , Plywood 12Mm Bwr Wall Panelling Cabinet Sides - 12Mm Bwr Is 303 8X4 Ft Sheet , Plywood 8Mm-Shutters, Drawer Fronts - 8Mm 8X4 Ft , Laminate Sheet Table Top And Cabin Accent - 1Mm Formica Or Merino Laminate 8X4 Ft , Veneer Sheet Md Table Top And Front - 0.6Mm Natural Walnut Veneer 8X4 Ft , Concealed Hinges Hettich Or Ebco All Shutters - 165 Soft-Close Concealed Hinge , Drawer Slides Full Extension Ebco Ball Bearing - 18 Inch Full Extension Ball Bearing Channel , Cabinet Handles Ss Bar Pull 160Mm Cc Brushed Chrome - Ss Brushed Chrome 160Mm Cc , Tape All Exposed Ply Edges - 22Mm Pvc Edge Banding 50M Roll , Md L Shape Executive Table Fabrication Labour - 6Ftx3ft + 3Ftx2.5Ft Return, 19Mm Bwr + Veneer , Full Height Wall Storage Cabinet Fabrication Labour - 8Ft Hx6ft W 2 Shutters 19Mm Bwr + Lam Finish , Decorative Wall Panelling Fabrication Labour - Work , Reception Counter Fabrication Labour - Work , Solid Wood Flush Door Md Cabin Walnut Veneer Both Sides - Work , Wooden Pelmet Or Ceiling Box Over Window Blind Concealment - 19Mm Bwr Box Walnut Veneer , Carpenter Labour Skilled Site Fabrication And Finishing - Work , Helper Labour Carpentry Material Handling And Assist - Work , 2.5 Sqmm Frls Copper Wire Power Points And Ac Circuits - 2.5Sqmm Frls 1100V 90M Coil , 1.5 Sqmm Frls Copper Wire Light And Fan Points - 1.5Sqmm Frls 90M Coil , 4.0 Sqmm Frls Copper Wire Ac Dedicated Circuit - 4Sqmm Frls 90M Coil , 25Mm Isi Pvc Conduit Pipe Concealed Wiring - Medium Duty Isi Pvc Conduit 3M Length , 20Mm Isi Pvc Conduit Pipe Light Circuits - Medium Duty Isi Pvc Conduit 3M Length , Modular Switches 6A Legrand Or Havells With Ms Box - 6A 1 Way Modular Switch With Plate And Ms Box , Modular 16A Power Sockets 5 Pin With 6A Switch - 16A 5 Pin Modular Socket With 6A Switch , Mcb Distribution Board 8-Way Double Door Surface Mount - Double-Door 8 Way Mcb Db Surface Mount , Led Recessed Downlight 22W Philips Or Havells Warm White - 21W Round Led Panel Warm White 3000K Ip20 , Earthing Pipe Gi 40Mm With Charcoal Salt Treatment - Gi Earth Electrode With Filling 3M , Light Point Wiring And Fixing Labour Concealed Conduit Per Point - Concealed Conduit Wiring Switch Fixing , Power Socket Point Wiring Labour 2.5Sqmm Per Point - Concealed Conduit 2.5Sqmm Wiring , Ac Point Wiring Labour -Dedicated 4Sqmm Circuit - Db To Ac Point Concealed Conduit And Wiring , Db Installation And Testing Labour Mcb Earthing Load Test - Mcb Wiring Earthing Connection Load Testing , Led Light Fixture Installation Fixing Connection Testing - All Light Fittings Fixed Wired And Tested , 600X600mm Vitrified Wood Carpet Area - Matt Wood Look Carpet , Laying Labour Levelling Grouting Cleaning - Skilled Mason Laying Levelling Grouting , Pop Work - Gepsum Board+ Labour , Wall Putty All Walls 2 Coats Asian Paints Or Birla - Asian Paints Trugard Birla White Putty 20Kg , Wall Primer Asian Paints Primer Plus 20L - Asian Paints Wall Primer 20L Pail , Premium Acrylic Emulsion Walls - Asian Paints Royale Matt I , Obd White Distemper Ceiling Asian Paints Tractor Emulsion 20L - Asian Paints Tractor Emulsion 20L , Paint Tools And Consumables Brushes Rollers Masking Plastic - Consumable Painting Tools And Protection Material , Pu Or Nc Polish Wooden Furniture Nc Or Pu Polish 1L Tin - Nc Or Pu Polish 1L Tin Approx 80 Sqft Per Coat , Wall Putty Labour 2 Coats 1000 Sqft Walls - Skilled Painter Putty 2 Coats On Walls , Wall Painting Labour Primer Plus 2 Coats Emulsion - Skilled Painter Brush Or Roller , Ceiling Painting Labour 2 Coats 250 Sqft - Skilled Painter Ceiling Painting , Pu Polish On Furniture Labour Sanding Primer 2 Pu Coats - Sanding Primer 2 Pu Coats Per Sqft , Biometric Unit Fingerprint Rfid - Standalone 500 Users , 12V Smps Power Supply Em Lock 2A Dc Adapter - 2A Dc Adapter For Em Lock Power , Exit Push Button Ss Flush Mount N O Contact With Label - Ss Exit Switch, No Contact With Label , Hydraulic Door Closer Dorma Or Stanley En3 Rated - En3 Rated Hydraulic Overhead Door Closer , Biometric Installation Labour Wiring Programming Testing - Installation Wiring Programming Testing , L Shape Fabric Sofa Cream Or Off White 3 Plus 2 Seater 36D Foam Hardwood Frame - Hardwood Frame, 36D Foam, Cream Linen Fabric , Fabric Sofa Bed Cream Or Off White 2 Seater 36D Foam Hardwood Frame - Hardwood Frame, 36D Foam, Cream Linen Fabric , Sofa Installation And Placement Labour Assembly Positioning Levelling - Assembly, Placement And Levelling , Visitor Chair White Shell Moulded Polypropylene Chrome Legs - Polypropylene Shell Chair, Chrome-Black Legs , Md Executive High Back Chair Leatherette Lumbar Tilt Adjustable - Leatherette, Lumbar, Adjustable Arms & Height, Tilt , Reception Desk Chair Mid Back Mesh Or Fabric Chrome Base - Mesh Or Fabric Mid-Back, Chrome Base, Height Adjust , Zebra Day Night Roller Blind All Windows Motorised Or Manual - Polyester Day-Night Zebra Blind , Aluminium Track And Brackets Blind Per Running Foot - Aluminium Track And Brackets For Blind , Blind Installation Labour Brackets Hanging Adjusting - Fixing Brackets, Hanging, Adjusting Blind Total Quantity : 4562
Contract Date: Ref. Documents Contract Value : 9.21 Lakh
Boards / Undertakings / PSU No of Bidders 4
Contract Date: Jun 15, 2026 Contract Value : 2.75 Crore
Government Departments No of Bidders 4
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
21.
Defence #11288161 AOC
Bids Are Invited For Miniature Circuit Breakers (Mcb) For Ac Operation Marked To Is/Iec 60898 (Part 1) (Q2) , Led Garden Light (V2) (Q2) , Self Ballasted Led Lamps (Led Bulb) (V3) Conforming To Is 16102 (Part 2) (Under Bis Scheme - Ii) (Q2) , Plasticized Pvc Tapes With Non-Thermosetting Adhesive For Electrical Purpose (V2) Isi Marked To Is 7809 (Part 3/ Sec1) (Q2) , Led Luminaire (Recessed Luminaire) (Ceiling Light) Conforming To Is 10322 (Part 5/Section 2) (V4) (Under Bis Scheme - Ii) (Q2) , Neroneon Led Strip Outdoor 8W220V , Ampi Rgb Controller 6 Amps , Neon Led Strip Connector 220V , Capo Led Outdoor Strip Connector 220V , Capo End Cap , Mounting Clamp , Capo Running Strip Amplifier 24V , Ampio Rgb Controller 12Amps , Ampio Rgb Controller 30Amps , Lso68 Connector With End Cap , Capo Connecting Wire , Strada Street Light 24W Light Sensor , Strada Street Light 72W Light Sensor , Alcor Sg Flood Light 30W Rgb , Alcor Sg Flood Light 9 50W , Alcor Lns Flood Light 400W Warmwhite , Nella Tunnel Light High Lumen 30W Warm White , Arco Linear Wall Washer 05 Mtr 30 12W , Arco Narrow Beam Light 10 18W , Avior High Bay Industrial Indoor Light 200W Warm White , Avior High Bay Outdoor Light 100W , Soltero Solar Garden Light 4W , Mirror Light Lita T7 12W Warm White , Zora Double Indor Wall Light 22W Warm White , Mirror Light Yota F2 12W , Mirror Light Yetta I3 6W Warm White , Mirror Light Yetta I4 12W Warm White , Indoor Wall Light Maira G3D S1 7W , Indoor Wall Light Holder Mabel Gwa 2 E27 Holder , Indoor Wall Light Holder Mio Gbs 1 E27 Holder , Indoor Wall Light Holder Bonito Ws5 E27 Holder , Indoor Wall Light Holder Bonito Ws11 E27 Holder , Indoor Wall Light Holder Bonito Ws12 E27 Holder , Indoor Wall Light Holder Bonito Ws16 E27 Holder , Indoor Wall Light Holder Bonito Ws17 E27 Holder , Indoor Wall Light Holder Bonito Ws18 E27 Holder , Indoor Wall Light Holder Bonito Ws19 E27 Holder , Indoor Wall Light Holder Bonito Ws26 E27 Holder , Indoor Wall Light Holder Ws23 Brass Body E27 Holder , Indoor Wall Light Holder Mika Ws5 E27 Holder , Indoor Wall Light Holder Ora Rw3 B22 Holder , Indoor Wall Light Holder Oria E27 Holder Lwl2041R , Indoor Wall Light Holder Oria E27 Holder Lwl2042R , Indoor Wall Light Chiara Wood F10 5W Warm White , Indoor Wall Lihgt Aura D2 2W Ww , Indoor Wall Lihgt Aura D4 7W Ww , Indoor Wall Lihgt Holder Aura Antique Indoor E27 Holder , Indoor Wall Lihgt Holder Aurablack Indoor E27 Holder , Indoor Wall Light Starla S1 8W Ww , Indoor Wall Light Starla S4 8W Ww , Indoor Wall Light Casso H1 Black 24W , Indoor Wall Light Casso S1 Black 24W , Indoor Wall Light Crysta W4 12W , Indoor Hanging Light Fixture Cairo P3 E27 Holder , Indoor Hanging Light Fixture Lindo Black E27 Holder , Indoor Hanging Light Fixture Lindo Gold E27 Holder , Indoor Hanging Light Fixture Bello Grey E27 Holder , Indoor Hanging Light Fixture Prigo P1 E27 Holder , Indoor Hanging Light Fixture Loro Gy E27 Holder , Indoor Hanging Light Fixture Londo P3 E27 Holder , Indoor Hanging Light Fixture Anzia Amber H13 E27 Holder , Outdoor Wall Light Halo W2 2X3 W , Outdoor Wall Light Halo W6 9W Ww , Outdoor Wall Light Halo W18 5W Ww , Outdoor Wall Light Halo W33 4X2W Ww , Outdoor Wall Light Ora Ow1 4W Ww , Outdoor Wall Light Ora Ow3 3W , Outdoor Wall Light Ora Ow4 2X3W , Fotis F5 Outdoor Footlight 6W Ww , Fotis F9 Pathway Light 6W Ww , Fotis F10 Inground Light 3W Ww , Fotis F11 Foot Light 3W Ip65Ww , Heliso Antique Fixture Big E27 Holder , Garden Light Holder Bubu B1 E27 Holder , Garden Light Cube S5 12W Ww , Underwater Fountain Light 12W24Vdc Ww , Underwater Cob Spot Light 8W24Vdc Ww , Ingroundunderwater Light 12W24Vdc Ww , Cct Tuneable Strip 120 Ledmtr , 1224V 2Ch Tuneable Strip Controller , Rgb Indoor Strip 60 Ledmtr , 24V5 Ch Rgbcww Strip Controller , Alcuno Accessorie Hanging Kit , Alcuno Accessorie Profile Hanging Kit , Alcuno Accessorie Surface Mounting Clips , Alcuno Accessorie Recessed Mounting Spring Clips , Alcuno Accessorie Straight Connector , Alcuno Accessorie120 Side Angle Connector , Alcuno Accessorie120 Top Angle Connector , Alcuno Accessorie 90 Side Angle Connector , Alcuno Accessorie 90 Top Angle Connector , Alcuno Accessorie Yconnector , Los68 Fixing Tape , Cabinet Light 5W 1 Ft , Earth Pit Chember At Top Dia155Mm At Bottom Dia210Mm Hight 240Mm , Earth Pit Chember Top Dia254Mm At Bottom Dia330Mm Hight 260Mm , Laser Suspended 28W , Buga Round Projectors 6W Rgbw , Led Reading Light 3W , Led Wall Light 15W , Led Spot Light Cob 12W Down Light , Led Spot Light Cob 15W Down Light , Led Spot Light Cob Zoom 30W Down Light , Led Spot Light Cob Zoom 40W Down Light , Led Track Lights Cob 15W Down Light , Led Track Lights Cob 20W Down Light , Led Underwater Fountain Light 6W Landscape , Led Underwater Fountain Light 12W Landscape , Led Underwater Light 6W Landscape , Led Underwater Light 12W Landscape , Led Surface Swimming Pool Light 6W Landscape , Led Surface Swimming Pool Light 12W Landscape , Led Recessed Swimming Pool Light 12W Landscape , Led Recessed Swimming Pool Light 18W Landscape , Led Inground Spike Light 7W Rgb , Led Wall Lamp 10W Wl 203 , Led Wall Lamp 10W Wl 200 , Led Wall Lamp 18W Black , Led Wall Lamp 18W Royal Blue , Led Wall Lamp 18W Gold , Led Wall Lamp 18W Bronze , Odl 7W Total Quantity : 6593
Contract Date: Ref. Documents Contract Value : 85.61 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
23.
Public Administrative Department #11278159 Technical Bid
Tender for Site Clearance: , Surface Dressing Of The Ground Including Removing Vegetation And In Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M. All Kinds Of Soil . , Earth Work: , Earth Work In Excavation By Mechanical Means (Hydraulic Wxcavator) Manual ,Eans In Foundation Trenches Ordrains Including Dressing Of Sides And Ramming Ofbottoms, Lift Uoto 1.5M Including Getting Out The Exavated Soil Anddisposal Of Surplus Excavated Soil As Directed Within A Lead Of 50M. , Antitermite Treatment: , Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos/Lindane Emulsifiable Concentrate Of 20%. , Back Filling Of Earth: , Filling Available Excavated Earth In Trenches Plinth Sides Of Foundation Etc.In Layer Not Exceeding 20 Cm In Depth Consolidating Each Deposited Layer By Ramming And Watering Lead Upto 50M And Lift Upto 1.5M. , Filling With Available Fly Ash And Earth In Trenches Bor Embankment In Layer With Intermediate Layer Of Compacted Earth After Every Four Layers Of Compacted Depth Of Fly Ash Sides & Top Layer Of Filling Shall Be Dine With Earth Having Total Minimum Compacted Thickness 30 Cm Or As Decided By Engineer -In- Charge Including Compacting Each Layer By Rolling Ramming And Watering All Complete As Per Drawing And Direction Of Enginner-In-Charge. , Supply & Filling In Plinth With Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete. , Plain Cement Concrete , Providing And Laying In Position Cement Concrete 1:4:8 Aggregated Excluding The Cost Of Centering And Shuttering-All Work Upto Plinth Level. , Reinforced Cement Concrete Work , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Excluding The Cost Of Centring Shuttering Finishing And Reinforced-All Work Upto Plinth Level 1:1.5:3 All Works Upto Plinth Level. . , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Excluding The Cost Of Centring Shuttering Finishing And Reinforced-All Work Upto Plinth Level 1:1.5:3 All Works Above Plinth Level Upto Floor V Level. , Plinth Protection , Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling & Dressing & Finishing The Top Smooth. , Shuttering & Centering , Centering Shuttering Including Strutting Propping Etc. And Removal Of From Work Foundations ,Footing ,Bases Of Column Etc. For Mass Concrete. , Centering Shuttering Including Strutting Propping Etc. And Removal Of From Work Columns ,Pillars,Piers, Abutments, Posts And Struts. , Centering Shuttering Including Strutting Propping Etc. And Removal Of From Work Suspended Floors ,Roofs,Landings, Balconies And Access Platform. , Centering Shuttering Including Strutting Propping Etc. And Removal Of From Work Lintels, Beams ,Plinth Beams,Girders, Bressumers And Cantilevers. , Reinforcement Of Steel , Reinforcement For Reinforced Cement Concrete Work Including Straighting Cutting,Bending,Placing In Position And Bending All Complete Themro-Mechanically Treated Bars. , Brick Work , 230Th Brick Work With Comman Burnt Clay F.P.S (Non Modular) Brick Of Class Designation 75 In Foundation & Plinth In Cement Mortar 1:6 , Brick Work With F.P.S Bricks Of Class 75 In Super Structure Above Plinth Level Up To Floor Five Level In All Shapes And Sizes In Cement Mortar 1:6 , Half Brick Masonry With F.P.S Bricks Of Class Designation 75 In Super Structure Above Plinth Level Up To Floor Five Level In Cement Mortar 1:4 , Door, Window, Ventilator , Providing And Fixing Two And Half Track Three Panels Sliding Window With Two Glazed & One Wire Mesh Panels With Aluminium Channel For Roller Track, Wool Pile, Nylon Rollers With Ss 304 Body. Using R2 Series With Frame (65 Mm & Above) X (40 Mm & Above) & Glazed Sash (25 Mm & Above) X (50 Mm & Above) & Fly Screen Sash (18 Mm & Above)X (40 Mm & Above) With Zinc Alloy (Zamak) Powder Coated Touch Locks With Hook (Height Upto 1.2 Metre). , Providing And Fixing Two Track Two Panels Sliding Door With Aluminium Channel For Roller Track, Wool Pile, Zinc Alloy (Zamak) Powder Coated Handle On Every Panel Along With Multi-Point Locking System, Adjustable Nylon Rollers With Ss 304 Body. Using R3 Series With Frame (55 Mm & Above) X (40 Mm & Above) & Sash (30 Mm & Above) X (7 4 Mm & Above). (Height Upto 2.5 Metre). , Providing And Fixing Fixed Window I Ventilator With Mullion I Transom. Using R1 Series With Frame (33 Mm & Above ) X (35 Mm & Above) & Mullion (33 Mm & Above) X (50 Mm & Above). (Height Upto 0.90 Metre) , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Extruded Printed And Laminated Section Having Overall Dimension 115 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm) With Inbuilt Beading On One Side, The Styles And Rails Mitred Cut And Joint At Corners By Inserting 2 Nos Pvc Profile Reinforcement Of Size 75 Mm X 200 Mm Long With Cross Section Size Of 28 Mm X 30 Mm Having Wall Thickness 2 Mm (± 0.2 Mm). Styles, Rails And Reinforcements To Be Fusion Welded Together. Only Hinge Side Vertical Style To Be Reinforced With Pvc Profile Reinforcement In Full Length , Railing Work , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Providing And Fixing Hand Rail Of Approved Size By Welding Etc. To Stee Ladder Railing, Balcony Railing, Staircase Railing And Similar Works, Including Applying Priming Coat Of Approved Steel Primer. M.S. Tube , Spiral Staircase (M.S) , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Providing And Fixing Hand Rail Of Approved Size By Welding Etc. To Stee Ladder Railing, Balcony Railing, Staircase Railing And Similar Works, Including Applying Priming Coat Of Approved Steel Primer. M.S. Tube , Plaster & Finishing Work , 12Mm Thick Plaster On The Plain In Side Of Mix 1:6 Mortar. , 15Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix. , 6Mm Thick Cement Plaster Of Ceiling Of Mix 1:6 Mortar. (Dsr 2023 -13.16.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade: New Work Over And Including Water Thinnable Priming Coat With Cement Prime. , Providing And Applying White Cement Based Putty Of Average Thickness 1Mm Of Approved Brand And Manufacturer,Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade: Two Or Nore Coats On New Work Over An Under Coat Of Suitable Shade With Oridinary Paint Of Approved Brand And Manufacture. , Flooring Work , Providing And Laying Verified Floor Tiles In Different Sizes With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Make In All Colours And Shades Laid On 20Mm Thick Cement Mortar 1:4 ,Jointing With Grey Cement Slurry @3.3Kg/Sq.M Including Groutibg The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600 X 600 Mm. , Providing And Fixing 1St Qaulity Ceramic Glazes Floor Tiles Conforming To Is:15622 Of Approved Make In All Colours Shades Except Burgundy Bottle Green Black Of Any Size As Approved By Engineer-In-Charge In Skirting,Risers Of Steps And Dados Over 12Mm Thick Bed Of Cement Mortar 1:3 And Jointing With Grey Cement Slurry @3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Fixing 1St Qaulity Ceramic Glazes Wall Tiles Conforming To Is:15622 Of Approved Make In All Colours Shades Except Burgundy Bottle Green Black Of Any Size As Approved By Engineer-In-Charge In Skirting,Risers Of Steps And Dados Over 12Mm Thick Bed Of Cement Mortar 1:3 And Jointing With Grey Cement Slurry @3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix Of 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg), Including Filling I Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. . , Providing And Laying Tactile Tile (For Vision Impaired Persons As Per Standards) Of Size 300X300x9.8 Mm Having With Water Absorption Less Than 0.5% And Conforming To Is:15622 Of Approved Make In All Colours And Shades In For Outdoor Floors Such As Footpath, Court Yard, Multi Modals Location Etc., Laid On 20 Mm Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) In All Shapes & Patterns Including Grouting The Joints With White Cement Mixed With Matching Pigments Etc. Complete As Per Direction Of Engineer-In-Charge. , False Ceiling , Providing And Fixing False Ceiling At All Heights Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Nclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X1 Ox0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre. , Water & Damp Proofing , Providing And Laying Water Proofing Treatment On Roofs Of Slabs By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying. ( , Drainage & Water Supply Works , Providing , Laying And Jointing Glazed Stoneware Pipes Class Sp-1 With Stiff Mixture Of Cement Mortar In The Proportion Of 1:1 Including Testing Of Joints Etc. 150 Mm Diameter , Providing And Fixing Square-Mouth S.W Gully Trap Class Sp-1 Complete With C.I Grating Brick Masonry Chamber With Wter Tight C.I Cover With Frame Of 300X300mm Size The Weight Of Cover To Be Not Less Than 4.50Kg And Frame To Be Not Less Than 2.70Kg. As Per Standard Design. , Providing And Laying Cement Concrete 1:5:10 All Round S.W Pips Including Bed Concrete As Per Standard Design. 15Mm Dia S.W Pipe. , Constructing Brick Masonry Chamber For Underground C.I Inspection Chamber And Bends With Bricks In Cement Mortar 1:4. 455X610 Mm Iternal Dimensions Total Weight Of Cover With Frame To Be Not Less Than 38Kg Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix , Providing And Fixing G.I Pipes Complete With G.I Fittings And Clsmps Including Cutting And Making Good The Walss Etc. Internal Work Exposed On Wall. , 15Mm Dia Nominal Bore , 25Mm Dia. Nominal Bore , 50Mm Dia. Nominal Bore , Providing And Fixing Ball Valve Of Approved Quality Complete High Or Low Pressure With Plastic Floats 25Mm Dia. Nominal Bore , Providing And Fixing Gun Metal Non-Return Valve Of Approved Quality :25Mm Nominal Bore. , Providing And Fixing Gun Metal Non-Return Valve Of Approved Quality :50Mm Nominal Bore. , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions 15Mm Nominal Bore. , Providing And Placing On Terrace Polyethylene Water Storage Tank Isi:12701 Marked With Cover And Suitble Locking Arrangement And Amking Necessary Holkes For Intel Outlet And Overflow Pipes But Without Fittings And The Base Vsupport For Tank. , Providing And Fixing Soil,Waste And Vent Pipes:Sand Cast Iron S&S Pipe As Per Is:1729 100Mm , Providing And Fixing Soil,Waste And Vent Pipes:Sand Cast Iron S&S Pipe As Per Is:1729 75Mm , Providing And Fixing Plain Bend Of Required Degree.100Mm Sand Cast Iron S &S As Per Is:1729 , Providing And Fixing Single Equalplain Invert Branch Of Required Degree.100X100x100mm Sand Cast Iron S &S As Per Is:1729 , Providing And Fixing Single Equalplain Invert Branch Of Required Degree.75X75x75mm Sand Cast Iron S &S As Per Is:1729 , Providing And Fixing Mirror Of Superior Glass And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6Mm Thick Hard Board Backing :Rectangular Shape 453X357mm. , Providing And Fixing Terminal Guard: Sand Cast Iron S&S Pipe As Peris-1729 , Providing And Fixing M.S Stays And Clamps For Sand Iron/Centrifugally Cast Iron Pipes Of Diameter:10Mm Dia. , Providing And Fixing C.P Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15Mm Nominal Bore. , Providing And Fixing C.P Brass Stop Cock Of Standard Design And Of Approved Make Conforming To Is:8931. 15Mm Nominal Bore. , Providing And Fixing C.P Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931. 15Mm Nominal Bore. , Providing And Fixing 450 Mm Long Towel Rail With Total Length Of 495 Mm, 78 Mm Wide And Effective Height Of 88 Mm, Weighing Not Less Than 170 Gms , Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes. 75 Mm Diameter , Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm Height Of 75Mm With Concealed Fitting Arrangments Weighing Not Less Than 106 Gms. , Sanitary Works , Providing And Fixing One Piece Construction White Vitreous China Squatting Plate With An Integral Longitudinal Flushing Pipe, White P.V.C. Automatic Flushing Cistern, With Fittings, Standard Size G.I. / Pvc Flush Pipe For Back And Front Flush With Standard Spreader Pipes With Fittings, G.I Clamps And C.P. Brass Coupling Complete, Including Painting Of Fittings And Cutting And Making Good The Walls And Floors Etc. Wherever Required :Range Of Two Squatting Plates With 5 Litre P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitrepous China Flat Back Or Wall Corner Type Lipped From Urinal Basin Of 430X260xx350mm And 340X410x265mm Size Respectively With Automatic Flushing Cistern With Standard Flush Pipe Abd C.P Brass Spreaders With Brass Unions And G.I Clamps Complete,Including Painting Of Fitting And Brackets Cutting And Making Good The Walls And Floors Wherver Required :One Urinal Basin With 5 Ltr. White P.V.C Automatic Flushing Cistern , Providing And Fixing Soil ,Waste And Vent Pipes Sand Cast Iron S&S Pipe As Per Is:1729 , 100Mm Dia. , 75Mm Dia. , Providing And Fixing Trap Of Self Cleaning Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete,Including Cost Of Cutting And Making Good The Walls And Floors: Sand Cast Iron S&S As Per Is-17 , Providing And Fixing Wash Basin With C.I Brackets, 15Mm C.P Brass Pillar Taps,32Mm C.P Brass Waste Of Standard Pattern,Including Painting Of Fitting And Brackets,Cutting And Making Good White Viterous China Wash Basin Size 630X450mm With Single 15Mm C.P Brass Pillar Tap , Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mminlet: 100Mm Diameter. , Electrical Work , Wiring For Light Point/Fan Point ,Exhaust Fan Point With 1.5Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface Steel Conduit With Modular Switch,Modular Plate Suitable G.I Box For Earhting The Point With 1.5 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable Isi Marked 1100 Volts Grade As Required For Group C Point Including Ceiling Rose And Lamps Holder As Required , Supplying And Fixing 5/6 Amps.Modular Type Switch On The Existing Modular Plate & Switch Box Including Cconnections But Excluding Modular Plate,Ac Etc. As Required. , Supply/Fixing 1 Or 2 Module Gi Box Of Size 75X75 Mm Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Required. , Supply/Fixing 3 Module Gi Box Of Size 100X75 Mm Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Required. , Supply/Fixing 6 Module Gi Box Of Size 200X75 Mm Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Required. , Supply/Fixing 8 Module Gi Box Of Size 125X125 Mm Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Required. , Supply/Fixing 12 Module Gi Box Of Size 200X150 Mm Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Required. , Supplying And Fixing Following Piano Type 3Pin 5/6A Socket Outlet. , Supplying And Fixing 3 Pin 5 Amps Ceiling Rose On The Existing Junction Box/Wooden Block Including Connections Etc As Required. , Supplying And Fixing Suitable Size G.I Box With Modular Plate And Cover In Front On Surface Including providing and Fixing 3 Pin 5\6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch Connections Etc. As Required. , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate And Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Suitable Size G.I Box With Modular Plate And Cover In Front On Surface Including providing and Fixing 6 Pin 15/16 Amps And 5/6 Amps Modular Socket Outlet And 15/16 Amps Modular Switch Connections Etc As Required. , Supplying And Fixing 6 Way Double Door Surface Mounting Vertical Type 240 Volts Tpn Mcb Distribution Board Of Sheet Steel Dust Protected Duly Powder Painted,Including Of 63 Amps Tinned Copper Bus Bars,Common Neutral Link,Earth Bar,Din Bar For Mounting Mcbs Of Havells Make Model Load Line Or Its Equivalent Of Legrand/Abb/L&T/Scienmense Make Inclduing Painting Earhting Etc. As Required. , Supplying And Fixing Single Pole 5Amps-32 Amps Rating 240/415 Volts C Series Miniature Circuit Breaker Suitable For Including Loand Of Following Pole In The Existing Mcb Db Complete With Connections,Testing And Commisioning Etc As Required. , Supplying And Fixing Of 200Mm Sweep Double Ball Bearing Type Exhaust Fan Of Make Usha/Crompton/Phllips/Or Its Equivalent In All Respect As Required And Directed By Enginner-In-Charge. , Led Down Lighter (Smd Type) (System Lumen Efficacy ≥ 105 120 Lm/Watt ) Supplying, Installation, Testing & Commissioning Of Led Recessed/ Surface Down Light. , 30 Watt , 12 -15 Watt , Led Batten Light (System Lumen Efficacy ≥105 120 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Led Surface Mounted Batten Light Of Following Body Material And Construction As Per Is : 10322 , 18- 22 Watt , Providing And Fixing 32 Amps Single Pole Mcb In Existing Cubical Panel Board Including Drilling Holes In Cubical Panel Making Connection Etc. Includingtesting And Commissioning Etc As Required. , Wiring For Circuit/Sub-Main Wiring Along With Earthwire The Following Size Of Frls Pvc Insulated Copper Conductor Single Core Cable I.S.I Marked 1100 Volts Grade In Surface/Recessed Steel Conduitas Required. , 2 X1.5 Sqmm+1X1.5 Sqmm Earth Wire , 2 X2.5 Sqmm+1X2.5 Sqmm Earth Wire , 2 X 4 Sqmm+1X4 Sqmm Earth Wire , 2 X 6 Sqmm+1X6sqmm Earth Wire , Supply , Installation,Testing And Commissiong Of 1200 Mm Sweep, Bee 5 Star Rated,Ceiling Fan. , Water Cooler , Ceiling Fan , Wall Hanging Fan , Interior Work , Furniture Work , Mid Back Mesh Revolving Chair Black , High Back Revolving Chair Black/Blue , Workstation 8 Seater (8 Seater Table) Size: 96X36X30 , Bookcase Steel (4 Shelf Glass) Size: 72X30X18 , Workstation 8 Seater (8 Seater Table) Size: 12X2x2 , Directior Table Size: 72X36X30 , 5 Seater Sofa With Table , Air Conditioner , 2 Ton 5 Star Voltas , 1 Ton 5 Star , A/C Installing Charge , Wall Stand , Computer , Hp A/O Desktop 27-Cr0902in I3-13T 8Gb/512Gb/Win/Mso , Hp A/O Desktop 24-Cr0902in I3-13T 8Gb/512Gb/Win/Ms , Hp Printer Smart Tank 580Aio P/S/C/W , Cctv Camera , Dvr Cp Plus 8Ch , Smps 10A , Bullet Camera 2.4Mp (Guard+Mic) , Dome Camera 2.4Mp (Guard+Mic) , Hdd 2Tb , Pvc Box , Bnc Connector Set , Rack 2U , Installation Charge , 3+1 Cable , 1.5 Mtr. Hdmi Cable , 32 Inch Led Smart Tv
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 8
Uttarakhand View Result →
24.
Defence #11276668 AOC
Tender For Welcome Maintenance To Omq Area Under Ge (Af) Srinagar.-- Sl. No. Item Description 1 Preparation Of Old Decorated Plastered Or Unplastered Surfaces Of Wall Including Filling Of Holes, Cracks And Undulating Surface With Cement Wall Care Putty Making Surface Even And Smooth And Applying One Coat Of Distemper Oil Emulsion Paint (Obd), Complete All As Specified And Directed 2 Preparation Of Old Decorated Plastered Or Unplastered Surfaces Of Wall Including Filling Of Holes, Cracks And Undulating Surface With Cement Wall Care Putty Making Surface Even And Smooth And Applying Two Coats Of Distemper Oil Emulsion Paint (Obd), Complete All As Specified And Directed 3 Complete Removal Of Existing Treatment From Wall Surfaces And Applying Two Coats Of Oil Bound Distemper Of Approved Colour Including Applying 1Mm Thick Jk Birla Wall Care Putty For Making The Surface Even And Smooth And Filling The Uneven And Small Holes And Making The Edges Of Plaster Properly By Plaster Of Paris Preparatory To Distempering Including Preparation Of Surface By Washing Rubbing Down And Stopping Of Distempered Surfaces, Complete All As Specified And Directed. 4 Preparation Of Old Plastered / Unplastered Old Decorated Surfaces Of Ceiling / False Ceiling, Cornices By Brooming Down Or Steel Brushing, Scraping Down Smoke. Moulds , Moss And Efflorescence Salts, Trading Oil Greasy Spots Etc. And Applying One Coat Of Oil Bound Distemper (Obd), Complete All As Specified And Directed 5 Preparation Of Old Plastered Or Unplastered Ceiling Surfaces And Applying One Coat Of White Wash, Complete All As Specified And Directed. 6 Preparation Of Old Plastered Or Unplastered Wall Surfaces And Applying One Coat Of White Wash, Complete All As Specified And Directed. 7 Preparation Of Old Plastered Or Unplastered Wall Surfaces And Applying Two Coats Of White Wash, Complete All As Specified And Directed. 8 Preparation Of Old Painted Steel & Iron Surfaces Of Any Description Over 10Cm Width Or Girth And Applying One Coat Synthetic Enamel Paint, Complete All As Specified And Directed. 9 Preparation Of Old Painted Wood Surfaces And Wood Based Materials Of Any Description Over 10Cm Width Or Girth And Applying One Coat Synthetic Enamel Paint, Complete All As Specified And Directed. 10 Preparation Of Old Plastered Surfaces Of Wall By Washing Down, Brooming Down Or Steel Wire Brushing Etc. And Applying One Coat Cement Base Paint, Complete All As Specified And Directed. 11 Complete Removal Of Existing Treatment From Brick Walls Or Concrete Plastered Or Unplastered Surfaces Including Scraping Down Smoke Soots, Moulds, Moss And Trading Oil And Greasy Spots Etc. Including Cornices, Pilasters Etc. And Applying Two Coats Of Cement Based Paint Over A Coat Of Primer, Complete All As Specified And Directed. 12 Complete Removal Of Existing Treatment From Brick Walls Or Concrete Plastered Or Unplastered Surfaces Including Scraping Down Smoke Soots, Moulds, Moss And Trading Oil And Greasy Spots Etc. Including Cornices, Pilasters Etc. And Applying Two Coats Of Weather Paint (Apex) Over A Coat Of Exterior Primer, Complete All As Specified And Directed. 13 Complete Removal Of Existing Treatment From Brick Walls Or Concrete Plastered Or Unplastered Surfaces Including Scraping Down Smoke Soots, Moulds, Moss And Trading Oil And Greasy Spots Etc. Including Cornices, Pilasters Etc. And Applying One Coat Of Weather Paint (Apex), Complete All As Specified And Directed. 14 M&L For French Polishing On Surfaces Of Any Description Width Or Girth Including Cleaning And Preparing The Surface Including A Coat Of Wood Filler On New Wooden Works With Two Or More Coats, Complete All As Specified And Directed. 15 S&F In Repairs 32/40 Mm Dia Bore Pvc Flexible Pipe For Wash Hand Basin / Urinal, Complete All As Specified And Directed. 16 S&F In Repairs 15Mm Size Pvc Connections With Ptmt Nuts Of Length 450Mm, Complete All As Specified And Directed. 17 S&F In Repairs Cp Health Faucet Fixed With Spring Action And Lever Along With Flexible Shower Hose With Brass Nut Of Length 1.5M Fitted In The Existing Water Connection In The Toilets, Complete All As Specified And Directed. 18 S&F In Repairs Brass Chromium Plated Tubular Towel Rail 20Mm Dia \D\ Type 60Cm Long Between Flanges, Complete All As Specified And Directed. 19 S&F In Repairs Plastic Water Closet Seat Cover Closed Pattern With Flat Bottom Cover And Mild Steel Chromium Plated Or Aluminized Hinging Device, Complete All As Specified And Directed. 20 S&F In Repairs 15Mm Bore Bib Tap, Cast Copper Alloy, Chromium Plated, With Capstan Handle, Screwed Down, Screwed From Iron Pipe Or For Brass Ferrule, Complete All As Specified And Directed. 21 S&F In Repairs 15Mm Bore Stop Valve / Angle Valve, Cast Copper Alloy, Chromium Plated, Fancy Type, Screwed Down High Pressure With Capstan Head, Complete All As Specified And Directed. 22 S&F In Repairs 15Mm Bore Hot And Cold Water Mixer With Swan Neck For Whb Chromium Plated Quarter Turn Screwed Down, Including Necessary Fittings, Complete All As Specified And Directed. 23 S&F In Repairs 15Mm Size Sink Mixer For Mixing Hot & Cold Water, Cast Copper Alloy Chromium Plated With Capstan Heads, High Pressure, With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe, Complete All As Specified And Directed. 24 S&F In Repairs 15Mm Bore Chromium Plated Wall Mixer 3-In-1 System Wall Mixer With Overhead And Hand Shower Arrangement With Connecting Legs, Wall Flanges And Wall Bracket For Hand Shower, Complete All As Specified And Directed. 25 S&F In Repairs 10 Litre Capacity Pvc Valveless, Syphonic Action Type, Flushing Cistern Low Level, White With Inlet Ball Valve, Float And Handle Including Brackets And Pvc Flush Pipe Etc., Complete All As Specified And Directed. 26 S&F In Repairs 5.5Mm Thick Sheet Glass Shelf Assembly Consisting Sheet Glass, Chromium Plated, 600Mm Long And 120Mm Wide With Chromium Plated Brackets, Guard Bar And Railing, Complete All As Specified And Directed. 27 S&F In Repairs Vitreous China Wash Hand Basin, White Flat Back, Size Of 550X400Mm Including Cutting For And Pinning In Ends Of Brackets (Including Supply And Fixing Of Brackets) Or Erecting Stand, 32Mm Brass Chromium Plated Waste Fitting With Long Screwed Shank And Fly Nut Flangedend Bedded In Red Led Cement, Chain And Plug And Porcelain Stopper, Complete All As Specified And Directed. 28 S&F In Repairs For 15Mm Bore Tubes, Medium Grade, Galvanised, With All Fitting, ( Such As Bends, Elbows, Tees, Short Pieces, Connectors, Back Nuts, Diminishing Pieces, Caps, Plugs, Unions Etc.) And Fixed Complete To And Ceiling With Clips, Wall Hooks, Wooden Plugs Or Laid In Floors Including Screwing And Waste And For Forged Bends On Piping As Required, Complete All As Specified And Directed. 29 S&F In Repairs For 20Mm Bore Tubes, Medium Grade, Galvanised, With All Fitting, ( Such As Bends, Elbows, Tees, Short Pieces, Connectors, Back Nuts, Diminishing Pieces, Caps, Plugs, Unions Etc.) And Fixed Complete To And Ceiling With Clips, Wall Hooks, Wooden Plugs Or Laid In Floors Including Screwing And Waste And For Forged Bends On Piping As Required, Complete All As Specified And Directed. 30 S&F 500 Litres Capacity Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified In Ssr Part I Including Dismantling Existing Water Tank And Removing From Site, Complete All As Specified And Directed. 31 Cleaning And Removing All Scale And Dirt, Etc. From Tanks And From Mouths Of Circulating Pipes, Etc Of Capacity Upto 500 Litres And Refixing The Float Valve And Plugging Wash Pipe, Complete All As Specified And Directed. 32 Cleaning And Removing All Scales And Dirt Etc. From Tanks And From Mouths Of Circulating Pipes Of Capacity Exc 500 Litres But N Exc 1000 Litres And Refixing The Float Valve And Plugging Wash Pipe, Complete All As Specified And Directed. 33 S&F In Repairs Cabinet Mirror Of Size 450X600Mm, Complete All As Specified And Directed. 34 Taking Down And Refixing Of Shutters In Same Opening After Easing And Adjusting Of Any Description Exc 1 Sqm And N Exc 2 Sqm Each Including Resecuring/Changing Of Builders Hardware, Complete All As Specified And Directed. 35 Taking Down Aluminium Door / Window Shutter Of Any Size N Exc 2.5 Sqm Each And Refixing In The Same Position / Opening After Easing And Adjusting, Tightening Of Joints Or Changes Of Hinges, Screws, Cleats, Beadings, Rubber Gasket Etc, As Per Site Requirement To Make Functional The Shutter, Complete All As Specified And Directed. 36 Taking Down Shutters Of Any Description Size Of Shutter Exc 1 Sqm But N.Exc 2 Sqm And Removing From Site Complete All As Specified And Directed. 37 Taking Down Chowkhats Or Frames With Shutters (Without Taking Off Shutters From The Frames) N Exc. 1.5 Sqm And Credited To The Contractor, Complete All As Specified And Directednote: The Damaged Portion Of The Tiles / Rendering Shall Be Made Good With The Same Material To Match With The Adjacent Surface. 38 Taking Down Chowkhats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Exc. 1.5 Sqm But N Exc 4.0 Sqm And Credited To The Contractor, Complete All As Specified And Directednote: The Damaged Portion Of The Tiles / Rendering Shall Be Made Good With The Same Material To Match With The Adjacent Surface. 39 S&F Pressed Steel Frame For Doors With One Rebates Size Of Frame 125X60 Mm Including Necessary Fixing Lungs Hinges Lock Strike Plate Etc. Including Pcc, 1:3:6, Type C-0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Back Filling Of Pressed Steel Frame, Complete All As Specified And Directed. 40 S&F Pressed Steel Frame For Doors With One Rebates Size Of Frame 105X60 Mm Including Necessary Fixing Lungs Hinges Lock Strike Plate Etc. Including Pcc, 1:3:6, Type C-0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Back Filling Of Pressed Steel Frame, Complete All As Specified And Directed. 41 S&F Anodised Aluminium Powder Coated Door Shutter With Frame (Minimum Thickness Of Powder Coating 50 Micron Of Approved Colour), Partly Glazed With 5Mm Thick Tinted Glass And Partly Panelled With 9Mm Thick Prelaminated Particle Board With Both Side Decorative Laminated Including Rubber Bead Joining Cleat For Fixing In Position, Aluminium Door Handle 150Mm Size, Aluminium Barrel Tower Bolt 200Mm Size, Mortice Lock Etc. All As Specified Below, Complete All As Specified And Directed. (A) Frame (Top & Side) Section Shall Of Size 101.60 X 44.75 X 2.4Mm (Section No 14021)(B) Vertical Members Of Shutter Section Shall Be Be Of Size 85.00 X 44.45 X 2.00Mm (Section No 19560)(C) Top Members Of Shutter Section Shall Be Be Of Size 83.50 X 44.45 X 2.00Mm (Section No 19581)(D) Lock Rail (Middle Member) Of Shutter Section Shall Be Be Of Size 150.00 X 44.45 X 3.00Mm (Section No 19596)(E) Bottom Members Of Shutter Section Shall Be Be Of Size 150.00 X 44.45 X 3.10Mm (Section No 19584) (F) Glazing Clip For Securing Glass Of Shutters Shall Be Be Of 0.80Mm Thick (Section No 19370).Note:- (I) Section No Given Above Are Of Make Jindal, Contractor May Use Similar Section Of Other Make Mention In Appx A(Ii) Floor Door Spring Will Be Measured & Paid Separately. 42 S&F Aluminium Powder Coated Aluminium Window Having Three Track (Minimum Thickness Of Powder Coating 50 Micron) With Aluminium Section 92Mm X 31.75Mm (Weight Bottom Section 1.070 Kg/M, Top Section 0.933 Kg/M, Shutter Section 40Mm X 18Mm (Weight Of Handle Section 0.417 Kg/M) Interlock 0.547 Kg/Rm Mounted On Bearing To Slide On Tracks Plain Anodized In Approved Shade Including Supply And Fixing Of 5Mm Thick Plain Glass And Wire Mesh, Pvc Track Gasket, Epdm Rubber Gasket On Glass Of Weather Tightening Along With Locks, Handle Including Sealing Gap With Marble Surfaces With Silicon Sealants Making It Water Proof In All Manner Etc. Complete All As Specified And Directed. 43 S&F Aluminium Powder Coated Ventilator (Minimum Thickness Of Powder Coating 50 Micron) Having Fixed Glass With Aluminium Section Having Section 50.80Mm X 25.40Mm (Weight 0.489 Kg/M) Glazing Clear Section (Weight 0.109 Kg/M) With Plain Anodized Including Supply And Fixing Of 5Mm Thick Sun / Heat Reflected Glass Making Frame And Glass Water Tightening Making It Good Etc., Complete All As Specified And Directed. 44 S&F For Powder Coated Aluminium Grill (Thickness Or Powder Coating Not Less Than 50 Micron) Of Approved Design / Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass / Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Powder Coated Aluminium Standard Section Around The Opening, Complete All As Specified And Directed. 45 S&F Upvc Windows With, Glass 5Mm Thick Clear Tough + 12Mm Thick A, G+5Mm Clear Toughened, Profile-Mozart Premium, Colour-White, Drainage, Face, Reinforcement Standard, T-Joints, Mechanical /V-Welded, Bead-Default, Mesh-Pull Down, Handle Type Cocksper Handle, Complete All As Specified And Directed. 46 S&F 4.8Mm Thick Sheet Glass Ordinary Quality And Glazing With Aluminium Glazing Clips And Rubber Neosprine Gasket In Square Or Rectangular In Section N Exc 0.5 Sqm In Each Pane, Complete All As Specified And Directed. 47 S&F Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S. Square Tube, Supplying And Fixing In Opening, Complete All As Specified And Directed. 48 S&F 30Mm Thick Factory Made Solid Pvc Moulded Door Shutter With Wood Free Eps, 28 To 30Mm Thick (Stiles), With 2, 4 Or 6 Raised Panel Design With 2Mm Thick Moulded Pvc Sheet On The Front Face And 2Mm Thick Plain Colour Pvc Sheet On Back Face, Suppling And Fining In Frame At Site As Per Specification And Drawing 49 S&F 35Mm Thick 2Nd Class Hardwood, Factory Made, Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze, Etc. (Without Sash Bars), Edges Of Framing Plain, Chamfered Or Rounded. Fitted With Cut And Mitred Beads For Securing Glass, Etc. Sizes Of Members Of Shutters As Specified In Ssr Part I, Section 8, Clause 8.24 (A), Complete All As Specified And Directed. 50 S&F 35Mm Thick 2Nd Class Hardwood Plain Framed, Panelled Shutter (Two Panel), Factory Made, With Lock Rail And Panel Of 9 Mm B.W.P. Commercial Ply Or 12 Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per Is : 1003 (Part I), Kiln Seasoned And Chemically Pressure Treated, Complete All As Specified And Directed. 51 S&F In Repairs 250Mm Mild Steel Helical Door Spring Rat Tail Type Including Collar Plate And Welding If Required Or Otherwise Fixed With Screw On Wooden Frames, Complete All As Specified And Directed. 52 S&F 150Mm Size Aluminium Anodised, Barrel Tower Bolts Of Extruded Section, Complete All As Specified And Directed. 53 S&F 100Mm Size Aluminium Anodised, Barrel Tower Bolts Of Extruded Section, Complete All As Specified And Directed. 54 S&F 150Mm Size Aluminium Handles, Cast Type, Anodised Complete All As Specified And Directed. 55 S&F 100Mm Size Aluminium Handles, Cast Type, Anodised Complete All As Specified And Directed. 56 S&F 100Mm Long Medium Weight, Cold Rolled Mild Steel Butt Hinges, Complete All As Specified And Directed.. 57 S&F 100Mm Long Floor Door Stopper Of Aluminium Alloy Body And Tongue With Rubber Cover Ends, Complete All As Specified And Directed. 58 S&F 250Mm Long Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp, Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts, Complete All As Specified And Directed. 59 S&F Mild Steel Wire Cloth 0.56Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18 In Steel / Wooden Shutter Of Door & Windows, Complete All As Specified And Directed. 60 S&F 3Mm Thick Sheet Glass Ordinary Quality And Glazing With Oil Putty / Wooden Beading In Squares Not Exceeding 0.50 Sqm Including Hacking Old Glass, Complete All As Specified And Directed. 61 S&F Door Strip Comprising Of Aluminium Holds & Rubber Strip Fixed At Bottom Of Door Shutter With Screws, Complete All As Specified And Directed. 62 S&F In Repairs 18-19Mm Thick Block Board, Grade-2 Quality, Interior Grade, Commercial Type, Fixed With Screws To Timber Framework As In Kitchen Drawers, Cupboard Shutters Etc. Complete All As Specified And Directed. 63 S&F 0.90Mm Thick Decorative Laminate Type 1 Of Surface Finish, Colour And Pattern As Approved, Fixed With Approved Adhesive As Per ManufacturerS Instructions, Complete All As Specified And Directed. 64 S&F 30Mm Width Of Flaps Continuous (Piano) Hinges, Stainless Steel, Bright Finish Or Electro Galvanised, Complete All As Specified And Directed. 65 S&F In Repairs 100Mm Long Hasp And Staple, Safety Type, Brass Aluminium Anodized With Mild Steel Hinge Pin Including Bolt To Hinge Plote And Fixed With Screw, Complete All As Specified And Directed. 66 S&F In Repairs Sink With Drainage Board Made Of Stainless Steel 1Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X 460Mm Bowl Size 410Mm X 330Mm X160Mm, Complete All As Specified And Directed. 67 S&F In Repairs Kitchen Plate Rack Made Of Stainless Steel 1Mm Thick With Plugs Washers As Overall Size Of 900Mm X 975Mm Including Fixing To Wall And All Accessories, Complete All As Specified And Directed. 68 S&F In Repairs 9Mm Thick Plywood, Grade Bwr, Type Bb, Fixed With Screws To Timber Frame Work Or Wall Panelling / Flooring / Ceiling, Complete All As Specified And Directed. 69 Preparation Of New Wood And Wood Based Surfaces Of Any Description Exc 10Cm With Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer, Complete All As Specified And Directed. 70 S&F In Repairs Snap Grid For False Ceiling Of Size 600Mm X 600Mm Grid Exposed Grid System Fabricated With Galvanised Iron Powder Coated Section All As Shown On Serial Page No 185 Of Ssr Part Ii (2020 Print), Complete All As Specified And Directed. 71 S&F 12Mm Thick Perforated Particle Boards Or Tiles For Insulation And Acoustic Purposes, 60Cm X 60Cm In Size, Fixed With Nails To Timber Frame Workorwith Staples On Snap Grid, Complete All As Specified And Directed. 72 S&F 6Mm Thick Non Asbestos Fibre Cement Building Boards Fixed Or Laid/Inserted To Timber /Gi / Aluminium Framework With Screws To Ceiling Flat Or Sloping, Complete All As Specified And Directed. 73 S&F In Repairs 12Mm Thick Wooden Wall Panelling Of Second Class Softwood With Tongue And Groove Joint Fixed In Any Position Over And Including Wooden Framework In Second Class Softwood With Plain Fillets Square Or Sectional Area Exc 13 Sqcm And N Exc 25 Sqcm At N Exc 90 Cm Centre To Centre In Both Direction And Including Two Or More Coats Of French Polishing On All The Exposed Surfaces Wooden Panelling Including Taking Down Existing Electrical Fittings And Re-Fixing The Same, Complete All As Specified And Directed. 74 S&F In Repairs Solid Pvc Wall Lining Consisting Of 5Mm Thick Wood Grain Printed Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame Including 5Mm Thick Pvc Sheet Fillet Of Width 35Mm For Wall Panelling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specifications,Complete All As Specified And Directed. 75 S&F In Repairs Decorative Type Wallpaper Of Good Quality Surface Finish, Colour ,Design And Pattern As Required Fixed With Approved Adhesive As Per ManufacturerS Instructions As Approved, Complete All As Specified And Directed. 76 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For, Complete All As Specified And Directed. 77 M&L For Structural Steel Work As In Truss, Rafter Purling, Made Out Of Angle / Hollow Pipe / Tube Section Including Jointing Cleats, Plates Flat Iron, Gusset Plates, Rails, Braces Etc. Conforming To Fe 410-W (Gde-E-250) Quality, Confirming To Is-1161-1979 Of Grade St-240 Complete All As Specified And As Directed. 78 S&F In Repairs 0.63Mm Thick Galvanised, Corrugated Mild Steel Sheeting With Two Corrugations Side Lap, With L-Type Or J-Type Or Cranked Hook Bolts, In Roofs, Walls Etc. With Grade Of Zinc Coating, Complete All As Specified And Directed. 79 S&F In Repairs Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws, Complete All As Specified And Directed. 80 S&F In Repairs Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws, Complete All As Specified And Directed. 81 M&L For Tightening Bolts And Closing Bolt Holes, Etc. To Rectify The Leakage / Seepage, In Old Roof Of Corrugated Steel Sheets By Sealing With One Bitumen And One Curved Gi Washer On Either Side And 6Mm G.I. Bolts And Nuts If Required, All Set In Stiff White Lead, Complete All As Specified And Directed. 82 Preparing New Zinc (Or Galvanised) Surfaces To Receive Painting Of Any Description Over 10Cm Width Or Girth, By Coating With Mordant Solution Including Washing And Cleaning, Etc. Steel And Iron Surfaces And Applying Two Coats Of Synthetic Enamel Paint Over One Coat Red Oxide Primer, Complete All As Specified And Directed. 83 Preparation Of Old Zinc (Or Galvanised) Steel And Iron Roof Surfaces Of Any Description Over 10 Cm Width Or Girth To Receive Painting, By Coating With Mordant Solution Including Washing And Cleaning Etc. And Applying Two Coats Of Synthetic Enamel Paint, Complete All As Specified And Directed. 84 Demolition Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc., Complete All As Specified And Directed. 85 M&L For 18-20Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Jambs, Pillars, Window Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Over And Including 15Mm Thick Screed Bed In Cm 1:4, Complete All As Specified And Directed. 86 Demolition Of Reinforced Cement Concrete Of Any Description In Any Position Not Otherwise Specifically Provided For, Complete All As Specified And Directed. 87 Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work For Fair Finished Surface, Not Exceeding 200M Thick (Horizontal Or Sloping), Complete All As Specified And Directed. 88 M&L For Reinforced Cement Concrete, 1:2:4, Type B-1 (Using 20 Mm Graded Crushed Stone Aggregate) For Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like, Complete All As Specified And Directed. 89 M&L For Ms Tmt Bars 10Mm Dia And Over, Cut To Length Bent To Shape Required Including Cranking, Bending Spirally For Hooking For Columns, Hooking Ends And Binding With And Including Mils Steel Wire (Annealed) Not Less Than 0.9Mm Dia Or Securing With Clips, Complete All As Specified And Directed. 90 S&F In Repairs 20Mm Dia Decorative Powder Coated Drapery Curtain Rods Of With Bright Finish, Including Decorative Side Domes, Brackets And A Minimum Of 8 Nos Curtain Rings In Per Running Metre Of Length, Complete All As Specified And Directed. 91 Demolition Of Brick Work Or Stone/ Boulder Masonry, Built In Cement Mortar Including All Quoins, Pillars Etc. Complete All As Specified And Directed. 92 M&L For Brick Work With Sub-Class `B Bricks (Using Old Size Bricks), Straight Or Curved On Plan Exceeding 6M Mean Radius Built In Cm 1:6, Complete All As Specified And Directed. 93 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc., Complete All As Specified And Directed. 94 M&L 15Mm Thick Rendering On Fair Faces Of Brick Work Or Concrete Surfaces In Cm 1:4 And Finishing Even And Smooth Without Using Extra Cement Using Integral Water Proofing Compound, Complete All As Specified And Directed. (Wpc Shall Be Measured And Paid Separately). 95 Supply Only Integral Water Proofing Compound, Complete All As Specified And Directed. 96 M&L For Rendering 15Mm Thick On Other Than Fair Faces Of Brick Or Concrete Surfaces In Cement Mortar 1:6, Finished Even And Smooth Without Using Extra Cement, Complete All As Specified And As Directed. 97 Preparation Of New Surface Of Wall And Applying Two Coats Of Cement Base Paint Over One Coat Of Primer, Complete All As Specified And Directed. 98 Preparation Of New Plastered Surfaces Of Walls And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Alkali Resistant Primer, Complete All As Specified And Directed. 99 M&L For Lagging To 15Mm Bore Pipes Used In External Water Supply Or Plumbing All Around With 50Mm Thick Bonded Mineral Wool Pre-Formed ‘Snap On’ Pipe Sections Of Density 144 Kg /Cum Conforming To Is 9842 Provided With Chicken Mesh Wire Netting 25Gauge 20Mm Mesh Including Applying With Brushing Neat Cement Slurry With 3 Kg Of Cement Per Sqm Including Taking Down Of Old Lagging If Required, Complete All As Specified And Directed. 100 M&L For Lagging To 20Mm Bore Pipes Used In External Water Supply Or Plumbing All Around With 50Mm Thick Bonded Mineral Wool Pre-Formed ‘Snap On’ Pipe Sections Of Density 144 Kg /Cum Conforming To Is 9842 Provided With Chicken Mesh Wire Netting 25Gauge 20Mm Mesh Including Applying With Brushing Neat Cement Slurry With 3 Kg Of Cement Per Sqm Including Taking Down Of Old Lagging If Required, Complete All As Specified And Directed. 101 S&F In Repairs 75Mm Dia Pvc (Swr) Soil Waste And Vent Pipes Single Socketed In Any Length With Rubber Ring Joints, Laid In Trenches Or Fixed To Walls, Complete All As Specified And Directed 102 S&F In Repairs 110Mm Dia Pvc (Swr) Soil Waste And Vent Pipes Single Socketed In Any Length With Rubber Ring Joints, Laid In Trenches Or Fixed To Walls, Complete All As Specified And Directed 103 M&L For Cleaning Surface Of Sunken Portion Wall / Bottom And Applying Cement Slurry @1.2 Kg Per Sqm And Applying 15Mm Thick Cement Plastred In Cm 1:3 Finished Even And Fair Using Extra Cement And Applying Two Coats Of Acrylic Polymer Modified Cementious Slurry As Per Manufactureas Instruction To Make The Surface Leak Proof, Complete All As Specified And Directed. 104 S&F In Repairs Vitreous China Wash Down Water Closet Pan (Pedestal Pattern), White (Excluding Flushing Cistern ) Including Connection To Drain (Or Outgoing Pipe) And To Flushing Pipe, Antisyphonage Pipe, Pvc Cover Sheet In Same Colour Etc., Complete All As Specified And Directed. 105 Dismantling Of Floor Hearth Or Wall Tiling Including Cement Mortar Bedding But Not Backing Removing Serviceable Tiles To Store And Rubbish Off The Premises, Complete All As Specified And Directed. 106 Demolition Of Cement Concrete In Ground Floors And Pavings N Exc 15Cm Thick (Below Or Above Ground Level), Complete All As Specified And Directed. 107 M&L For 25Mm Thick Plain Cement Concrete, 1:2:4, Type B-0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Sub Base Of Floor Finish Even And Rough To Receive Further Floor Finishes (Tile/Kota Stone/ Marble ), Complete All As Specified And Directed. 108 M&L For 100Mm Thick Plain Cement Concrete, 1:2:4, Type B-1 (Using 20Mm Graded Crushed Stone Aggregate) As In Flooring , Laid In Alternate Bays And Finishing The Surface Even And Smooth Without Using Extra Cement, Complete All As Specified And As Directed. 109 M&L For Non Skid Ceramic Coloured Tiles 7 To 8Mm Thick (Square / Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match Over And Including 15Mm Thick Screed Bed In Cm 1:4, Complete All As Specified And Directed. 110 M&L For Glazed Ceramic Tile 300X600X06-7Mm Thick (Coloured) On Vertical Surfaces Such As Wall, Dados Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Shade Of Tiles Over And Including 10Mm Thick Screed Bed In Cm 1:4, Complete All As Specified And Directed. 111 M&L For Light Shade Vitrified Ceramic Tiles 8 To 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15 Mm Thick Screed Bed In Cm 1:4, Complete All As Specified And Directed. 112 M&L For Light Shade Vitrified Ceramic Tiles 8 To 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 10 Mm Thick Backing Coat Cm 1:4, Complete All As Specified And Directed. 113 M&L For 75Mm Thick Plain Cement Concrete, 1:4:8, Type D-2 (Using 40 Mm Graded Crushed Stone Aggregate) As In Sub Base, Complete All As Specified And Directed. 114 M&L For 100Mm Thick Plain Cement Concrete, 1:4:8, Type D-2 (Using 40 Mm Graded Crushed Stone Aggregate) As In Sub Base, Complete All As Specified And Directed. 115 M&L For 10Mm Thick Vitrified Parking Tiles Heavy Duty, Exterior Grade, Textured Finished Of Size 300X300Mm Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cm 1:4, Complete All As Specified And Directed. 116 M&L For Chequered Cement Concrete Tiles Size 300 Mm X 300 Mm X 22-25Mm Thick With Grey Cement And Pigment , Rubber Moulded With Laquer Polish For Extra Shine, Isi Marked, Coloured, Set Jointed And Pointed In Neat Cement Slurry Over And Including 20Mm Thick Screed Bed In Cm 1:6, Complete All As Specified And Directed. 117 M&L For Strong Silicone Sealant Suitable For Roof Leak Hole, Metal Leak, Gap Filling Etc. Hole Size N Exc 5X5Mm Including Necessary Fitting And Scaffolding Height Upto 15M, Complete All As Specified And Directed. 118 S&F In Repairs Pvc Syphon Kit For One Piece, Complete All As Specified And Directed. 119 S&F In Repairs One Piece Closet Seat Cover Closed Pattern With Flat Bottom Cover And Mild Steel Chromium Plated Or Aluminized Hinging Device, Complete All As Specified And Directed. 120 S&F In Repairs 100Mm Dia Cp Grating Doom, Complete All As Specified And Directed. 121 Deduction To Be Made From Boq For Schedule A Part-Ii (Credit Schedule From Dismantling / Taking Down Items) Worth Rs 65,905.00 During Aoc.(Note :- Tenderers Shall Not Quote For This Schedule) Please Enable Macros To View Boq Information
Contract Date: Jun 29, 2026 Contract Value : 19.33 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Jammu And Kashmir View Result →
25.
Tourism #11266721 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Madhya Pradesh View Result →
27.
Public Administrative Department #11258623 AOC
Tender For Late Maharshi Annasaheb Shinde School to carry out various development works at this place=ITEM NO : 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m.) By Manual Means ( SSR Item No : 21.01 ) (PMC Bhavan ) Unique No (15201) Rate List Year (2024-2025) ITEM NO : 2 Transportation of material obtained from excavation including soil, Cu.M rubble, bricks, RCC concrete, kerb stones, steel railing, iron pipes, channels etc. Obtained from excavation, dismantling, loading in a Truck of minimum 5 Cu M capacity or designed capacity and transporting within the municipal limits or any designated place, unloading, stacking or spreading of material etc. complete. As directed by Engineer In charge ( SSR Item No : 78.36 ) (PMC Bhavan ) Unique No (17223) Rate List Year (2024-2025) ITEM NO : 3 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete ( SSR Item No : 46.19 ) (PMC Bhavan ) Unique No (16026) Rate List Year (2024-2025) ITEM NO : 4 Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. ( SSR Item No : 33.67 ) (PMC Bhavan ) Unique No (15532) Rate List Year (2024-2025)ITEM NO : 5 Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. ( SSR Item No : 33.27 ) (PMC Bhavan ) Unique No (15495) Rate List Year (2024-2025) ITEM NO : 6 Providing internal cement plaster 12 mm thick in a single coat using Ready to use wall plaster to concrete or brick surface in all positions including scaffolding and curing complete. Providing groove at joint of B.B. Masonry and concrete members complete. c) cement ratio 1:3 With Prior Approval of Concerned S.E. ( SSR Item No : 51.F-108 ) (PMC Bhavan ) Unique No (16252) Rate List Year (2024-2025) ITEM NO : 7 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item Number 15 to 18 prior approval of Superintending Engineer will be necessary ( SSR Item No : 35.26 ) (PMC Bhavan ) Unique No (15576) Rate List Year (2024-2025) ITEM NO : 8 Wall Painting art work : painting artistic work on any type of surface and at any height using scaffolding with skilled artists as per the instructions of site incharge.measurement will be as per actual max.size of art.rate for background apex paint and lettring will be paid seperately ( SSR Item No : 63.4 ) (PMC Bhavan ) Unique No (16694) Rate List Year (2024-2025) ITEM NO : 9 Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. ( SSR Item No : 36.11 ) (PMC Bhavan ) Unique No (15587) Rate List Year (2024-2025) ITEM NO : 10 Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. ( SSR Item No : 35.12 ) (PMC Bhavan ) Unique No (15563) Rate List Year (2024-2025) ITEM NO : 11 Providing and fixing frame with / without ventilator of size as specified with Country non teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. ( SSR Item No : 39.2 ) (PMC Bhavan ) Unique No (15676) Rate List Year (2024-2025) ITEM NO : 12 Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. ( SSR Item No : 39.10 ) (PMC Bhavan ) Unique No (15684) Rate List Year (2024-2025) ITEM NO : 13 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. ( SSR Item No : 46.15 ) (PMC Bhavan ) Unique No (16022) Rate List Year (2024-2025) ITEM NO : 14 Providing and fixing 24 gauge plain aluminium sheet on the face of door shutter including cutting to required size and fixing the screws including making good the damages if any to existing door shutter and frame etc. complete as directed or as per detailed drawing ( SSR Item No : 39.62 ) (PMC Bhavan ) Unique No (15739) Rate List Year (2024-2025) ITEM NO : 15 Providing and fixing Orissa type white glazed earthenware water closet pan of size 260mm x 440mm x 580mm with approved make Slim wall hung cistern with installation kit including S or P trap with cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc.complete. ( SSR Item No : 48.42 ) (PMC Bhavan ) Unique No (16111) Rate List Year (2024-2025) ITEM NO : 16 Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. ( SSR Item No : 42.34 ) (PMC Bhavan ) Unique No (15886) Rate List Year (2024-2025) ITEM NO : 17 Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. ( SSR Item No : 41.63 ) (PMC Bhavan ) Unique No (15838) Rate List Year (2024-2025) ITEM NO : 18 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres ( SSR Item No : 42.54 ) (PMC Bhavan ) Unique No (15906) Rate List Year (2024-2025) ITEM NO : 19 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. ( SSR Item No : 42.52 ) (PMC Bhavan ) Unique No (15904) Rate List Year (2024-2025) ITEM NO : 20 Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. ( SSR Item No : 31.05 ) (PMC Bhavan ) Unique No (15422) Rate List Year (2024-2025) ITEM NO : 21 Providing and laying River Finish kota Stone Flooring 50mm to 60mm thick and of required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. etc. complete. ( SSR Item No : 60.08 ) (PMC Bhavan ) Unique No (16469) Rate List Year (2024-2025) ITEM NO : 22 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( SSR Item No : 25.11 ) (PMC Bhavan ) Unique No (15317) Rate List Year (2024-2025) ITEM NO : 23 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Number : As directed by Engineer-in-charge. ( SSR Item No : 23.07 ) (PMC Bhavan ) Unique No (15303) Rate List Year (2024-2025) ITEM NO : 24 Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super bib tap with flange including all accessories etc complete ( SSR Item No : 43.35 ) (PMC Bhavan ) Unique No (15975) Rate List Year (2024-2025) ITEM NO : 25 Building (Bd-V : Water supply and sanitory fittings)Upvc sanitary pipes all 15 mm dia. ( SSR Item No : 49.V-354 ) (PMC Bhavan ) Unique No (18025) Rate List Year (2024-2025) ITEM NO : 26 Building (Bd-V : Water supply and sanitory fittings)Upvc sanitary pipes all 25 mm dia. ( SSR Item No : 49.V-353 ) (PMC Bhavan ) Unique No (18024) Rate List Year (2024-2025) ITEM NO : 27 Building (Bd-V : Water supply and sanitory fittings)P.V.C.Flushing tank (12 ltr. Capacity) ( SSR Item No : 49.V-202 ) (PMC Bhavan ) Unique No (17873) Rate List Year (2024-2025) ITEM NO : 28 Building (Bd-V : Water supply and sanitory fittings)super jet spray with flange 2 in 1 faucet 1.50 metre long SSR Item No : 49.V-385 ) (PMC Bhavan ) Unique No (18056) Rate List Year (2024-2025) ITEM NO : 29 Building (Bd-V : Water supply and sanitory fittings)Ball cock for 32mm dia. SSR Item No : 49.V-279 ) (PMC Bhavan ) Unique No (17950) Rate List Year (2024-2025) ITEM NO : 30 Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete. SSR Item No : 46.39 ) (PMC Bhavan ) Unique No (16044) Rate List Year (2024-2025) ITEM NO : 31 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. SSR Item No : 39.37 ) (PMC Bhavan ) Unique No (15711) Rate List Year (2024-2025) ITEM NO : 32 Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram / Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram / Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box SSR Item No : 39.41 ) (PMC Bhavan ) Unique No (15715) Rate List Year (2024-2025) ITEM NO : 33 Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). SSR Item No : 38.4 ) (PMC Bhavan ) Unique No (15625) Rate List Year (2024-2025) ITEM NO : 34 Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). SSR Item No : 39.26 ) (PMC Bhavan ) Unique No (15700) Rate List Year (2024-2025) ITEM NO : 35 Providing and fixing 12 mm thick waterproof plywood ( durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI) ) SSR Item No : 62.11 ) (PMC Bhavan ) Unique No (16542) Rate List Year (2024-2025) ITEM NO : 36 Providing and fixing 19 mm thick waterproof plywood ( durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI) ) ( SSR Item No : 62.12 ) (PMC Bhavan ) Unique No (16543) Rate List Year (2024-2025) ITEM NO : 37 Providing & fixing 1/2”,1/4”to 1” tk Teakwood leaping patti including polishing etc completed. ( SSR Item No : 62.27 ) (PMC Bhavan ) Unique No (16570) Rate List Year (2024-2025) ITEM NO : 38 Laminates sheets 1 mm thick : Providing and fixing laminates sheets as per company specification and fix it with fevicol – Recommended companies- formica, Royal touch, Marino , Green lam , Euro. ( 1 mm thick laminates sheets ) ( SSR Item No : 62.23 ) (PMC Bhavan ) Unique No (16566) Rate List Year (2024-2025) ITEM NO : 39 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) . Handles ( SSR Item No : 62.29-B ) (PMC Bhavan ) Unique No (16573) Rate List Year (2024-2025) ITEM NO : 40 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) .Hinges ( SSR Item No : 62.29-A ) (PMC Bhavan ) Unique No (16572) Rate List Year (2024-2025) ITEM NO : 41 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) . Locks (For cupboards & wardrobes) ( SSR Item No : 62.29-C ) (PMC Bhavan ) Unique No (16574) Rate List Year (2024-2025)
Contract Date: Feb 26, 2026 Contract Value : 19.94 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 29.88 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Madhya Pradesh View Result →
29.
Defence #11208243 AOC
Bids Are invited for Operation And Maintenance Of Lifts (Elevators) - Complete System - Maintenance And Operation Of Lift No 3-28-S8121, 3-28-S8122 & 3-28-S8123 Through Amc (Minimum Platinum Level) Under Repair, Replacement, Overhaulling, Maintenance Of Lifts Through Tke / Accredited Agencies Installed At Ep Md Accn Bhubaneswar Of Capacity 13 Passengers Including Necessary Minor Repair / Replacement Of Defective Parts Work If Required In Any Emergency And Kept The The Lift In Working Condition At Round The Clock Complete All As Specified And Directed.(Note: 13 Passenger Capacity Lift -03 Nos)Notes For Item No 1.00 :-1. Service The Lifts At Regular Intervals And As Frequently As The Company Deems Necessary Based On The Age, Nature And Condition Of The Elevator And Will Take All Responsible Care And Maintain The Lift Equipment In Safe And Proper Working Condition.2. Carry Out The Services Work Whenever Possible On Day Convenient To The Customer Other Than Sunday And Holiday And During Regular Working Hours.3. Depute An Entitled Authorised Service Personnel To Attend All Call Backs During Normal Working Hours And Also If Any Emergency Even After Working Hours.4. Replenish The Gear And Motor Bearing With Necessary Johnson/Authorised Lubricants Whenever Necessary Including Checking /Cleaning Of All Moving Parts And Keep Them Both Electrically And Mechanically In Perfect Working Condition .Notes For Item No 1.00 (Contd):- 5. Checking Of Minimum/Maximum Oil Levels Of Gear, Motor And Guide Lubricant Tank Complete All As Directed.6. Lubrication Of Motor Bearing , Brake Pivets , Weel Bearing , Mechanical Limit Switches, Gate Rollers And Tracks, Safety Gear Mechanisum, Lock And Rollers, Connecting Wires , Retiring Ram Etc Complete All As Directed.7. The Rate Quoted Is Deemed To Be Inclusive To Tools And Safety Equipment, Crc Spary, Minor Consumables Such As Pvc Insulation Tape, Screws, Fuse Wire, Clips,Freuuel,Locks,First Aid Box Required For Running And Maintenance Of Plants8. Inspection Of Electrical System Such As Main Switch, Over Load Protection, Control Relays , Connecting Wires, Single Phase Preventor, Main And Lighting Fuses, Contact Allingments Etc All As Directed. , Supply Install & Commissioning For Ard Battery 12V 7Ah Complete All As Specified & Directed. , Supply Install & Commissioning For Cross Blower Fan 2500 Rpm Complete All As Specified & Directed
Contract Date: Ref. Documents Contract Value : 6.94 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
30.
Defence #11208242 AOC
Bids Are invited for Operation And Maintenance Of Lifts (Elevators) - Complete System - Maintenance And Operation Of Lift No L-G9691 & L-G9692 Through Amc (Minimum Platinum Level) Under Repair, Replacement, Overhaulling, Maintenance Of Lifts Through Jhonson(Oems) / Accredited Agencies Installed At Cgae Hanger Bhubaneswar Of Capacity 13 Passengers Including Necessary Minor Repair / Replacement Of Defective Parts Work If Required In Any Emergency And Kept The The Lift In Working Condition At Round The Clock Complete All As Specified And Directed.Notes For Item No 1.00 :-1. Service The Lifts At Regular Intervals And As Frequently As The Company Deems Necessary Based On The Age, Nature And Condition Of The Elevator And Will Take All Responsible Care And Maintain The Lift Equipment In Safe And Proper Working Condition.2. Carry Out The Services Work Whenever Possible On Day Convenient To The Customer Other Than Sunday And Holiday And During Regular Working Hours.3. Depute An Entitled Authorised Service Personnel To Attend All Call Backs During Normal Working Hours And Also If Any Emergency Even After Working Hours.4. Replenish The Gear And Motor Bearing With Necessary Johnson/Authorised Lubricants Whenever Necessary Including Checking /Cleaning Of All Moving Parts And Keep Them Both Electrically And Mechanically In Perfect Working Condition .Notes For Item No 1.00 (Contd):- 5. Checking Of Minimum/Maximum Oil Levels Of Gear, Motor And Guide Lubricant Tank Complete All As Directed.6. Lubrication Of Motor Bearing , Brake Pivets , Weel Bearing , Mechanical Limit Switches, Gate Rollers And Tracks, Safety Gear Mechanisum, Lock And Rollers, Connecting Wires , Retiring Ram Etc Complete All As Directed.7. The Rate Quoted Is Deemed To Be Inclusive To Tools And Safety Equipment, Crc Spary, Minor Consumables Such As Pvc Insulation Tape, Screws, Fuse Wire, Clips,Freuuel,Locks,First Aid Box Required For Running And Maintenance Of Plants8. Inspection Of Electrical System Such As Main Switch, Over Load Protection, Control Relays , Connecting Wires, Single Phase Preventor, Main And Lighting Fuses, Contact Allingments Etc All As Directed.9. Checking And Inspection Of Motor Terminals, Brake Liners, Coupling Bushes, Limit Switches, Ultimate Limit Switch Magnetic Switches , Push Button Movements, Brake Shoes, Noise Level, Working Condition Of Leds, Gate Lock, Spindle Movement, Condition Of Lock Brake Condition Of Rubber Roller , Mechanical Lock Plate , Rope Anchorages, Tightness Of Rope Clips, Position Of Equaliser , Trailing Of Cables, Condition Of Cable , Door Allingment Clearance Between Vain And Rollers, All Mechanism Bolts , Door Bearings, Floor Anounciator Working Condition, Door Skate, Conditon Of Door Switches, Safety Edges Etc Complete All As Directed.10. Checking Of All Emergency Devices Such As Ard Working Condition, Battery Condition, Over Load Device Working Condition, Over Load Anounciator And Display Condition, Emergency Ligh Working Condition, Emergency Siren Alaram Condition , Charing Unit Condition Etc.Complete All As Directed.11. Checking Of Lift Well Lighting, Machine Room Lighting, Machine Room Ventilators , Machine Room Door Including Cleaning Of Machine Room, Lift Well, Enclosure, Landing Gates, Car Gates, Car Inside, Lift Pit Etc 10. Checking Of All Emergency Devices Such As Ard Working Condition, Battery Condition, Over Load Device Working Condition, Over Load Anounciator And Display Condition, Emergency Ligh Working Condition, Emergency Siren Alaram Condition , Charing Unit Condition Etc.Complete All As Directed.11. Checking Of Lift Well Lighting, Machine Room Lighting, Machine Room Ventilators , Machine Room Door Including Cleaning Of Machine Room, Lift Well, Enclosure, Landing Gates, Car Gates, Car Inside, Lift Pit Etc 12.Checking The Following Devices :- (A) Breake Releasing Mechanisum Working Condition (J) Press And Speek Working Condition (B) Break Lock Nut Measurement In Mm (K) Shaft Controller Wiring Tightness (C) Break Arm Switch (L) Oil Buffer Working Condition And Oil Level (D) Emergency Battaery Condition (M) Any Abnormal Noise Obseerved. (E) Trap Door Access Condition. (N) Carryout The Load Testing Ones In A Year (F) Breake Plunger Lock Nut Tightness (O) Regularly Cheaking Of Ard System (G) Additional Car Gate Lock Contact (P) Consequence Cheakinh Of Fault Electrical System. (H) Controller Light Working Condition (Q) Consequence Cheakinh Of Earthing System. , Spare Parts For Lift No L-G9691 & L-G9692 , 12 Cabin Fan Regular Black Guard And Silver Coloue Blade (Remi)-02 Nos , Led Downlighter (Wipro)-3W-Model Ld80-200-Xxx-60-Xx - (05 Nos) , Smps 12V Dc,50W,4A , 10A 110 V Dc Contactor Siemens , 10A 110 V Dc Contactor Siemens , Battery Amaron 12V -18 Ah , Battery Amaron12v -2.5 Ah
Contract Date: Ref. Documents Contract Value : 5.55 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
31.
Public Administrative Department #11199742 AOC
Carrying Out Civil Maintenance Work For The Phase 1,2,3,4 At Ravet Pumping Station.-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for thefoundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Excavation for foundation in earth, soils of all types, sand ,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed forthe foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means Providing general pest control services to the building to control the nuisance of cockroaches, lizards, pin bores and other insects etc. with 4 operations in a year and monthly check up. Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete. Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. Ground Floor Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs anddrawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. Providing Gas or Electrical welding for structural steel section, plates as per detailed drawing. For less than 10 mm thick section. Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.(Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Lift 0.0 to 3.8 M Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, f oundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No.: Bd.F.17, Page No. 306 Ground Floor Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc .complete. Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Lift 0.0 to 3.8 M Providing Second class fly ash brick masonry with conventional / I.S. type bricks cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete. Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Gound Floor Removing the tar or coba and disposing of the material as directed etc. complete. Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, after application TP- 42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee-LM @ 700 gms/ One Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/ One Square Metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplast fibre @ 125 gms/ One Square Metre to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. Providing and Applying DuraClean- WR for cleaning the TMT bars, steel structure etc. of structure by Waterjet cleaning/ grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal surface also removing loose particles(using other mechanical / manual means) and apply on prepared surface of DuraGuard - as corrosion preventive coat on prepared TMT bars, steel structure,metal surface etc. to protect it from corrosion etc. as per manufacturers specification ( using other manual / mechinical means) complete as per specification including cost of all materials, machinery, labour, insurance charges as directed by the Engineer in charge. Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor Lift 0.0 to 3.8 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of to 15 mm thick in C.M. 1:4 rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Providing flush grooved pointing with cement mortar 1:3 for brick work including scaffolding and curing etc. complete. Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. line and level including neat finishing scaffolding curing etc. complete. Providing and laying Polished Tandur Stone flooring 25mm to 30mm thick required width in plain/ diamond pattern on bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Providing sills of polished Kadappa stone 25mm to 30mm thick, on a bed of 1:4 cement mortar including cement float, filling joints with slurry, curing polishing and cleaning etc. complete. Providing and fixing heavy duty inter locking concrete Grey paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in requiredposition laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Ground Floor Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Ground Floor Removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. complete. Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning preparing the plaster surface applying primer coat scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary Scrapping the old plastered internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding etc. complete as directed. Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. excluding the primer coat.) etc. complete. Lift 0.0 to 3.8 M Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 mm x 40 mm weighing 0.39 Kilogram/m. at 60 cms c/c and fixed with ( 15 x 15 mm) flanges weighing 0.119 Kilogram/m suspended on 6 mm dia. mild steel rod weighing 0.22 Kilogram/m fixed on wall and beams including rounding of the edges with aluminium T of 50 mm x 40 mm weighing 0.39 Kilogram/m etc. including all labour etc. complete. Providing and fixing false ceiling of 15mm thick as per drawings including powder coated G.I. wall angle of 20 mm x 20 mm x 0.60 mm size, G.I. grid runners of size 15 mm x 38 mm at 600 mm center to center both ways and suspended using G.I. 3 mm wire including fixing using butterfly clips and fasteners including transporting, scaffolding all necessary labour and machinery, finishing etc. complete. Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 Kilogram/sq.m.). Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Providing and fixing factory made panelled door shutter in single leaf 35 mm thick style and rail without ventilator with CCTW panels 12 mm thick including wrought iron hold fast and stainless steel fixtures with oil painting 3 coats etc. complete. Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One RunningMetre. Inter locking section 40 x 18 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass withall required screws and nuts etc, complete. With colour Anodising with box. etc
Contract Date: Jun 01, 2026 Contract Value : 44.74 Lakh
Local Bodies No of Bidders 4
Maharashtra View Result →
34.
Housing Urban and Rular Development #11179853 Technical Bid
Tender for Synthetic Running Track At Sports Stadium Distt. Muzaffarnagar [U.P.]
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
35.
Educational and Research Institute #11176915 AOC
Providing and fixing Aluminum Partition and Aerocon Panels Partition - Providing and fixing Aluminum Partition and Aerocon Panels Partition 2 Providing and fixing in position extruded aluminium partitions having frame made out of extruded tubular section of size 65 mm x 40 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 129231990, laminated on both sides, Novateak or equivalent with aluminium glazing clips of size 12 mm x 12 mm (conical) as per drawing etc. complete. 3 Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc. complete. 4 Providing and fixing of Aerocon panel partition of approved make of size 3.00 mtr × 0.6 mtr and thickness 75mm on MS ANGLE 75mm × 75mm × 5mm in length & 50mm × 5mm flats in longitudinal on spacing of 600mm direction welded back to back with required screws including fixtures and fastenings, gaps to be filled by POP with necessary scaffolding with all lead and lift, machinery and equipment charges etc. complete as directed by Engineer in Charge. 5 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating without box 6 Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box
Contract Date: May 26, 2026 Contract Value : 10,472
Government Departments No of Bidders 3
Maharashtra View Result →
37.
Rural Development #11132493 AOC
Tender For Construction Of Gram Panchayat Bhawan At Bembla Tq Karanja - Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means--Specification No--Bd.A.1 Page One Number 259 -SSR 2022-23 INo21.02 3 Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto1.50m)ByMechanical Means--Specification No--Bd.A.2 Page One Number 259 -SSR 2022-23 INo21.06 4 Providingsoling using80mm sizetrapmetalin15cm.layerincludingfilling voidswith Crushed sand/grit, ramming, watering etc. complete.--Specification No--As directed by Engineer incharge. -SSR 2022-23 INo21.4 5 ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd. E. 1 Page One Number 287 -SSR 2022-23 INo24.01 6 Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneiss metalforR.C.C.work infoundationslikeraft,stripfoundations,grillageand footingsofR.C.C.columnsandsteelstanchions etc.includingbailingoutwater, Steel centeringformwork,laying/pumpingcoverblocks,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd.F.3 Page One Number 298 and B.7, Page One Number38 -SSR 2022-23 INo25.11 7 ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd.F.5 Page One Number 300 and B.7,Page.One Number 38 -SSR 2022-23 INo25.31 8 ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirectedincludingsteelcentering,formwork,coverblocks,laying/pumping, compactionandrougheningthesurfaceifspecialfinishistobeprovidedandcuringetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd.F.6 Page One Number 300 and B.7, Page One Number38 -SSR 2022-23 INo25.5 9 ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd.F.8 Page One Number 302 and B.7, Page One Number38 -SSR 2022-23 INo25.7 10 Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADA enabledreversibleDrum Typemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate (Crushed sand VSI Grade)--Specification No--Bd.F.9 Page One Number 303 and B.7, Page One Number38 -SSR 2022-23 INo26.05 11 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters forR.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.--Specification No--Bd.F.17, Page One Number 306 -SSR 2022-23 INo26.33 12 Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposedfaces, raking out joints on exposedfaces and watering etc. Complete.--Specification No--Bd.G. 1 PageOne Number 313 -SSR 2022-23 INo27.01 13 Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,wateringandscaffolding etc. Complete--Specification No--Bd.G.5 Page One Number 315 -SSR 2022-23 INo27.05 14 Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placedat every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.--Specification No--Bd.G.7 Page One Number 316 -SSR 2022-23 INo27.06 15 Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.layersincluding watering and compacting etc. complete.--Specification No--Bd.A.10 PageOne Number 262 -SSR 2022-23 INo21.36 16 Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to20cmincludingwateringandcompactionetc.complete.--Specification No--Bd.A.11 Page One Number 263 -SSR 2022-23 INo21.37 17 Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete.--Specification No--Bd. L.2 Page One Number 368 -SSR 2022-23 INo32.04 18 Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:5withoutneeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete--Specification No--Bd.L.4 Page One Number 368 -SSR 2022-23 INo32.06 19 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete.--Specification No--As directed by Engineer incharge. -SSR 2022-23 INo32.34 20 Providing neeru finish to plastered surfaces in all positions including scaffolding and curingetc. complete.--Specification No--Bd. L.10, PageOne Number370 -SSR 2022-23 INo32.15 21 Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.Cmembersandbrickwork,ofapprovedqualityincludingfixing meshinpositionby necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.--Specification No--As directed by Engineer in Charge: -SSR 2022-23 INo32.26 22 Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of1:4cementmortarincludingneatcementfloat,fillingjoints,curingandclearing etc. complete.--Specification No--Bd.M. 12 Page One Number385 -SSR 2022-23 INo33.4 23 Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete--Specification No--Bd.M. 12 Page One Number385 -SSR 2022-23 INo33.41 24 Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to givetheappearanceoftilesof30cmx30cmorothersizelaiddiagonally/squareetc finishing smooth (with extra cement) in any colour as directed and curing etc.complete.with Crushed sand VSI Grade--Specification No--Bd.M.7 Page One Number 383 -SSR 2022-23 INo33.09 25 Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete.--Specification No--As directed by Engineer-In- Charge -SSR 2022-23 INo33.68 26 Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc.complete.--Specification No--Bd.0.8 Page One Number 406 -SSR 2022-23 INo35.13 27 Providing and applying plastic emulsion paint of approved quality, colour and shade to old andnewsurfacesintwocoatsincludingscaffolding,preparingthesurface.(excludingthe primer coat)etc. complete.--Specification No--Bd.P.6 Page One Number 414 -SSR 2022-23 INo36.12 28 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium platedfixturesandfastenings,withbrassmortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete.--Specification No--BD-T-34PageOne Number 499 -SSR 2022-23 INo39.09 29 Providing andfixing inposition(asper1868/1982)Aluminium sliding windowofthree tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeofbearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre.Inter locking section 40x 18x 1.10mm atweight0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm atweighto.417Kilogram/Runningmetre.Asperdetaileddrawingsandasdirectedby Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainlesssteeljailwithall required screws and nuts etc, complete. With powder coating without box--Specification No--As directed by Engineer in charge. -SSR 2022-23 INo39.44 30 Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metreasperdrawingincludingfixturesnecessaryweldingandpaintingwithonecoatof anticorrosive paint and two coats of oil painting complete.--Specification No--Bd.U.1 Page One Number 537 -SSR 2022-23 INo40.02 31 Providing and fixing board displaying information, such as Name of work, Tender cost, Name of Contractor, Work completion and liability period etc, having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge --Specification No--MORTH 801 -SSR 2022-23 INo6.36 32 Clean the surface to remove dirt, loose particles. Examine the surface closely for any cracks. Clean the cracks. Provide and fill a pure acrylic, polymer modified ready to use paste Polyfill ARof approved make & approved by Engineer in charge having a cream coloured viscous emulsion ready to use acrylic polymeric non-shrink crackfiller putty with auto suction properties and requiring no bonding agent, no curing and no requirement for opening the existing cracks finishing with subsequent filling as required. Provide and apply three coats of 100% acrylic waterproof heat insulating breathable decorative external coating Sunext 8of approved make &approved by Engineer in charge, in the desired shade. Stir well and apply by brush for three coats. Applying three coats at an interval of 4-6 hours between each coat.High Performance 100% Acrylic, Waterproof, Anti-fungal, Anti-carbonation, Heat Insulating External Paint should have following minimum properties:1. Specific Gravity: 1.3 ± 0.1 at 25°C2. pH: 7.0 to 10.003. Viscosity: 18 to 30 sec. at 25°C by Ford Cup One Number B-4 (Dilute 2 parts of product with 1 part of water)4. CO2 diffusion resistance co- efficient (DIN EN 1062-6 (2002-10): 7.59 x1055. CO2 diffusion equivalent air layer thickness (DIN EN 1062-6 (2002-10): 127m @ 190 microns DFT6. Adhesion (ASTM D 4541): 2.3 N/mm2 (Concrete / Substrate Failure)7. Solar Reflectance Index (ASTM E 1980 11,EN 673:2011, EN 410:2011): 107 It shall be applied as per manufacturers specification.--Specification No--As directed by Engineer in charge -SSR 2022-23 INo50.1
Contract Date: May 21, 2026 Contract Value : 16.26 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
38.
Defence #11118340 AOC
Bids Are Invited For Supply Of Cement Opc 43 Grade Packed In Hdpe Bag Each Of 50 Kg Wt Of Make Birla Gold Or Ambuja Or Ultratech Or Acc Or Jk And Dalmiya , Coarse Sand Free From Vegetation , Coarse Aggregate 20Mm Graded , Coarse Aggregate 40Mm Graded , Coarse Aggregate 40 To 63 Mm Graded , Stone For Rr Masonary Less Than 6 Inch , Mild Steel Of Size 8Mm Dia Confirming To Is 432 Part I 1982 Of Make Tata Or Sail Or Jsw , Mild Steel Bar Of Size 10Mm And Above Dia Confirming To Is 432 Part I 1982 Of Make Tata Or Sail Or Jsw , Mild Steel Bars Of Size 12Mm And Above Dia Conforming To Is 432 Part I 1982 Of Make Of Tata Or Sail Or Jsw , Mild Steel Bars Of Size 16 Mm And Above Dia Conforming To Is 432 Part I 1982 Make Of Tata Or Sail Or Jsw , Ms Binding Wire , Wooden Plank For Shuttering 2Nd Class Wood Size Of 3.0 X 0.30 X 0.026M , Wooden Scantlilng Various Size , Wooden Log For Props Of Size 3.2 Mtr Ling 100Mm Dia , App Based Poymeric Membrane Minimum Weighing 3Kg Per Sfqm Min 3Mm Thick Reinforced Polyster Non Wove Fabric Wt Not Less Than 150Gm Per Sqm Land On Primed Surface By Forced Apllication , Priming Surface And Applting Bitumen As A Primer In Base Of App Membrane , Ms Frame Work For Roof Trusses, Purlin, Rafter And Ms Plate Etc All As Per Technical Specification Of Make Tata Or Sail Or Jsw Or Ms Rhs Of Size 80 X 40 X 3.2 , Ms Frame For Roof Trusses, Purlin, Rafter And Ms Plate Etc All As Per Technical Specification Of Make Tata Or Sail Or Jsw Of Ms Rhs Of Size 50 X 25 X 2.9 , Ms Frame For Roof Trusses, Purlin, Rafter And Ms Plate Etc All As Per Technical Specification Of Make Tata Or Sail Or Jsw Of Ms Rhs Of Size 96 X 48 X 3.2 , Ms Frame For Roof Trusses, Purlin, Rafter And Ms Plate Etc All As Per Technical Specification Of Make Tata Or Sail Or Jsw Of Ms Plate Of Size 8Mm Thick , Ms Frame For Roof Trusses, Purlin, Rafter And Ms Plate Etc All As Per Technical Specification Of Make Tata Or Sail Or Jsw Of Ms Plate Of Size 10Mm Thick , Ms Frame For Roof Trusses, Purlin, Rafter And Ms Plate Etc All As Per Technical Specification Of Make Tata Or Sail Or Jsw Of Ms Place Of Size 12Mm Thick , Ms Frame For Roof Trusses, Purlin, Rafter And Ms Plate Etc All As Per Technical Specification Of Make Tata Or Sail Or Jsw Of Ms Angle Of Size 40 X 40 X 6 For Cleat , Ms Nuts And Bolts Of Length 100Mm Fully Thread Suitable For 10 Mm Dia Nuts Including Two Numbers Of Washers And 25Mm Of Shank And Two Nos Of Washers 3 Mm Thick Complete All As Directed. , Ms Flat Iron 40X5Mm Thick For Wind Tie Of Make Tata Or Sail Or Jsw , Iron Welding Rod Confirming To Is 814-2002 Isi Marked 3.15Mm Thick 100 Nos Pkt , Water Proofing Compoundconfirming To Is 2645- 2003 Of Make Pidilite Or Dr.Fixit And Fevicol , Quick Setting Compound Of Make Pidilite Or Fevicol And Quick Fix , Cement Based Paint Snowce Make Berger Or Asian Or Nerolac , Oil Bound Distemper Washable Quality Of Proprietary Brand Of Make Nerolac Or Berger Or Asian. , Oil Bound Distemper Washable Quality Of Proprietary Brand Of Make Nerolac Or Berger Or Asian , Ppgi Roofing Sheet 10 Feet By 3 Feet Long And Thickness 0 Point 8 Mm With Grard Film To Cater For Snow Load Conditions Upto 1 Point 5 Meter. All Specification As Per Ts , Pre Painted Galvatume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0 Point 50 Mm Thick An Colour Having A Tensile Strength 550 Mpa Make Uniix Or Jindal Mectec Or Eqv Brand , Synthetic Paint Enamelled Og Colour Confirming To Is 5 2004 Make Berger Or Asian Or Nerolac , Painting Brush 4 Inch , Nails Various Sizes , Self Taping Steel Screw Half Thread With Rawl Plug Of 1 And Half Inch Size Isi Marked Of 100 Nos Per Pkt , Anodised Aluminium Door 1000 Mm X 2100 Double Shutter With Frame Including All Fittings And As Per Tech Specification Make Jindal Or Hindalco Aluminium Section Weighing 0 Point 55 Kg Per Mtr. , Anodised Aluminium Window Triple Track 2 Track Glass 1 Track Wire Mesh Frame Size 1000 X 1000Mm Including All Fittings Directed Make Jindal Or Hindalco Aluminium Section Weighing 0.55 Kg Per Mtr , Anodised Aluminium Ventilator 1200X600 Mm Fixed Type With Glass Of 4Mm Thick Including All Fittings And As Directed Make Jindal Or Hindalco Aluminium Section Weighing 0 Point 55 Kg Per Mtr. , Ms Anchor Bolt Suitable For Rcc Work 12Mm Dia 300Mm Long With 2 Washer And A Nut Minimum Wt Of Each Bolt And Nut Is 450 Gm Complete All As Directed. , Ceramic Tiles Of Size 600 Mm X 600 Mm For Floor Thickness Between 9 To 10 Mm Thick Make Johnson Or Kajaria Or Orient Of 1St Quality Confroming To Is 156 2006 , White Cement Confirming To Is 8042 1989 Make Acc Or Birla White Or Ambuja , Hdpe Sand Bag Og Colour Of Size 0.75 X 0.375 X 0.15 , Curtain Arrangement Drapery And Rod Made Of 25 Mm Dia And 1600 Mm Long Pre Coated Ms Pipe With Fancy Type Ends. All As Per Ts , Cement For Retaining Wall Height 8 X 3 Mtr Length 40 Mtr Running Mtr Opc 43 Grade Packed Hdpe Bag Each 50 Kg Wt Make Birla Gold Or Ambuja Or Ultratech Or Acc Or Jk Or Dalmia , Coarse Sand Free From Vegetation Confirming To Is 650 1991 Reaffirmed 2008 , Coarse Aggregate 40Mm Graded Confirming To Is 383 2016 , Stone Boulder 9 Inch To 12 Inch Confirming To Is 1597 Part I 1992 Reaffirmed 2002 , Pvc Pipe 75Mm Dia 3 Mtr Long Make Prince Or Finolex Or Supreme Confirming To Is 4985 2000 Reaffirmed 2006 , Cement For Drain And Sump 43 Grade Opc Packed In Hdpe Bag Each 50 Kg Wt Conform To Is 8112 1989 Make Birla Gold Or Ambuja Or Ultratech Or Acc Or Jk Or Dalmia , Coarse Sand Free From Vegetation , Hardcore 63 To 90 Mm Graded , Brick Sub Class B , Three Phase 1.2 Hp Monoblock Pump 430 Volt Complete With And Incl 3 Mtr Length Required Size Flexible Suction Pipe Foot Valve And Connected Accessories Complete All As Ts , Distribution Box 8 Way Spn 240 Volts Copper Bus Bar And Neutral Link Earthing Stud Conforming To Is 13032 And Is 8623 Double Door Type Make Havells Or Legrand Or L And T , Mcb Spn 240 Volts 32 Amps Make Havells Or L And T And Standard , Mcb Sp 6 To 32 Amps Make Havells Or L And T Or Standard , Pvc Tape 19Mm Wide 5 M Long Make Steelgrip Or Anchor Or Kinjal , Cable Pvc Insulated Electric Cables Heavy Duty 1100 Volts Grade Multi Stranded Copper Conductor Of Size 1.5 Sqmm Single Core Frls Confirming To Is 1554 Part 1 1988 Make Havells Or Finolex Or Polycab , Cable Pvc Insulated Electric Cables Heavy Duty 1100 Volts Grade Multi Stranded Copper Conductor Of Size 2.5 Sqmm Single Core Frls Confirming To Is 1554 Part 1 1988 Make Havells Or Finolex Or Polycab , Cable Pvc Insulated Electric Cables Heavy Duty 1100 Volts Grade Multi Stranded Copper Conductor Of Size 4 Sqmm Single Core Frls Confirming To Is 1554 Part 1 1988 Make Havells Or Finolex Or Polycab , Pvc Casing Capping Of Size 1 Inch Medium Grade Snow White Make Presto Or Polycab Or Finolex , Pvc Casing Capping Of Size 3 By 4 Inch Medium Grade Snow White Make Presto Or Polycab Or Finolex , Modular Switch Piano 5 Amp 230 Volts Flush Type One Way Snow White Make Anchor Or Ssk Or Cona , Led Tube Light Fittings 15W 230V Box Type 4 Feets With Crca Body Pre Coated White And Prewired For Led Tuble Complete Make Havells Or Bajaj Or Philips Or Crompton , Led Mirror Lights 1 Feet 5 Watts Make Havelles Or Bajaj Or Philips Or Crompton , Screw Full Thread 6 X 19 Mm Isi Marked 200 Nos Pkt , Pvc Switch Board Snow White Size 6 Inch X 6 Inch For Sockets And Switches Make Supreme Or Polycab Or Finolex , Pvc Switch Board Snow White Size 7X4 Inch For Sockets And Switches Make Supreme Or Polycab Or Finolex , Pvc Switch Board Snow White Size 8 X 10 Inch For Main Switches Or Db Make Supreme Or Polycab Or Finolex , Pvc L Bend And T Junction Joint For Pvc Casing And Capping Confirming To Is 3419 Part 3 Make Supreme Or Polycab Or Finolex , Modular Switch Socket Combination Snow White Multipurpose 2 In 1 15 Amp 230 Volts Make Anchor Or Ssk Or Cona , Modular Switch Socket Combination Snow White 5 Amp 230 Volts Make Anchor Or Ssk Or Cona , Service Bracket 40Mm Dia Gi Tubing Medium Grade 1.5 Mtr Long Make Jindal Or Tata Or Kalinga , Service Cable Pvc Insulated Aluminium Conductor 1100 Volt Grade Heavy Duty Served With Inner Sheathing Of Pvc Tap And Overall Pvc Sheathed In Service Connection 10 Sqmm 2 Core , Ceiling Rose Three Terminal Snow White Make Anchor Or Ssk Or Cona , Led Bulk Head Fitting High Pressure Die Cast Aluminum Front Cover With Glass Cover With Specially Design Gasket With Led Lamp 10 Watts Make Havells Or Bajaj Or Philips Or Crompton , Pvc Flexible Wire Copper Conductor Multi Stranded 0.0016 Of 76 Make Havells Or Finolex Or Plaza , Pvc Flexible Conduit Pipe 15 Mm Dia Make Polycab Or Supreme Or Finolex , Pvc Round Or Square Block Make Polycab Or Supreme Or Finolex , Exhaust Fan 230 Volts 300 Mm Sweep Plastic Body Alongwith Louvers And Complete Fittings Make Bajaj Or Havells Or Crompton , Fire Extinguisher Of One Kilogram Capacity Dry Power Type Conforming To Is 13849 Along With Its Accessories Make Cease Fire Or Omex Or Alfa Fire , Earthing Plate 600 X 600 X 6 Mm Galvanised Steel Suitable For Gi Strip Fittings, Drilled With 2 Nos Holes For 6 Mm Dia Near One Side. , Ci Earth Pit Cover Of Size 300 X 300 X 6 Mm With Angle Iron Of Size Total Quantity : 8562
Contract Date: Ref. Documents Contract Value : 24.97 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
39.
Tourism #11114098 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Cornices & Mouldings , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 150 Mm Strip Between Five Stone For Grassing.Strips To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.( Price Including Stone, Gardening Soil, Fertilizer And Grass Etc. ) , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Of Flashing Tape Along Wall And Tile Jointes ( Abutment Area ) Including Fixing Of Aluminium Strip Above Flash Including Sealing The Top Edge With Uv Resistant Sealant Etc Complete. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Extra For Plastering Done On Mouldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Mts. Lead. , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. A) Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. B) Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. C) Theming Work For Nandi Kalash In Frp As Per Tender Drawing , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Rough Dressing The Trenched Ground Including Breaking Clods. , Fine Dressing The Trenched Ground. , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Of Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevatia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Sebestena , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Foxtail Palms , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Callistemon (Bottlebrush Tree) , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Mimusops Elengi , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 60 To 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 40-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Pf=0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -5 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (A) 5 To 20 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying & Erecting Of Led 12W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A
Contract Date: Jul 02, 2026 Contract Value : 3.70 Crore
Government Departments No of Bidders 2
40.
Public Administrative Department #11109429 AOC
Tender For Master Plan Kalagram At P.L. Deshpande Udyan To Carry Out Various Development Works Remaining work -ITEM NO : 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m.) By Manual Means ( SSR Item No : 21.01 ) (PMC Bhavan ) Unique No (15201) Rate List Year (2024-2025) ITEM NO : 2 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. ( SSR Item No : 46.09 ) (PMC Bhavan ) Unique No (16016) Rate List Year (2024-2025) ITEM NO : 3 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. ( SSR Item No : 46.12 ) (PMC Bhavan ) Unique No (16019) Rate List Year (2024-2025) ITEM NO : 4 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. ( SSR Item No : 46.13 ) (PMC Bhavan ) Unique No (16020) Rate List Year (2024-2025) ITEM NO : 5 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete ( SSR Item No : 46.19 ) (PMC Bhavan ) Unique No (16026) Rate List Year (2024-2025) ITEM NO : 6 Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. SSR Item No : 46.14 ) (PMC Bhavan ) Unique No (16021) Rate List Year (2024-2025) ITEM NO : 7 Transportation of material obtained from excavation including soil, Cu.M rubble, bricks, RCC concrete, kerb stones, steel railing, iron pipes, channels etc. Obtained from excavation, dismantling, loading in a Truck of minimum 5 Cu M capacity or designed capacity and transporting within the municipal limits or any designated place, unloading, stacking or spreading of material etc. complete. As directed by Engineer In charge SSR Item No : 78.36 ) (PMC Bhavan ) Unique No (17223) Rate List Year (2024-2025) ITEM NO : 8 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. SSR Item No : 21.36 ) (PMC Bhavan ) Unique No (15231) Rate List Year (2024-2025) ITEM NO : 9 Providing leather finished polishing to Kota / Marble / Shahabad Kadappa Stone slab by continuous grinding in 4 coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. SSR Item No : 33.57 ) (PMC Bhavan ) Unique No (15525) Rate List Year (2024-2025) ITEM NO : 10 Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. SSR Item No : 21.38 ) (PMC Bhavan ) Unique No (15233) Rate List Year (2024-2025) ITEM NO : 11 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( SSR Item No : 24.04 ) (PMC Bhavan ) Unique No (15309) Rate List Year (2024-2025) ITEM NO : 12 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( SSR Item No : 25.50 ) (PMC Bhavan ) Unique No (15327) Rate List Year (2024-2025) ITEM NO : 13 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( SSR Item No : 25.31 ) (PMC Bhavan ) Unique No (15322) Rate List Year (2024-2025) ITEM NO : 14 Providing first class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth including bailing out water manually, striking joints on unexposed faces, pointing with cement mortar 1:3 on exposed face and watering etc. Complete. ( SSR Item No : 27.02 ) (PMC Bhavan ) Unique No (15371) Rate List Year (2024-2025) ITEM NO : 15 Providing uncoursed rubble masonry of trap / granite / quartzite gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. SSR Item No : 28.01 ) (PMC Bhavan ) Unique No (15385) Rate List Year (2024-2025) ITEM NO : 16 Providing flush grooved pointing with cement mortar 1:3 for stone masonry work including scaffolding and curing etc. complete. SSR Item No : 32.17 ) (PMC Bhavan ) Unique No (15449) Rate List Year (2024-2025) ITEM NO : 17 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound 1Kilogramper cement bag curing the same for not less than days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1: finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. SSR Item No : 32.11 ) (PMC Bhavan ) Unique No (15444) Rate List Year (2024-2025) ITEM NO : 18 Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. SSR Item No : 23.02 ) (PMC Bhavan ) Unique No (15298) Rate List Year (2024-2025) ITEM NO : 19 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Number : As directed by Engineer-in-charge. SSR Item No : 23.07 ) (PMC Bhavan ) Unique No (15303) Rate List Year (2024-2025) ITEM NO : 20 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. ( SSR Item No : 26.33 ) (PMC Bhavan ) Unique No (15352) Rate List Year (2024-2025) ITEM NO : 21 Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete. ( SSR Item No : 42.37 ) (PMC Bhavan ) Unique No (15889) Rate List Year (2024-2025) ITEM NO : 22 Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super Pillar tap with flange including all accessories etc complete ( SSR Item No : 43.41 ) (PMC Bhavan ) Unique No (15981) Rate List Year (2024-2025) ITEM NO : 23 Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super bib tap with flange including all accessories etc complete ( SSR Item No : 43.35 ) (PMC Bhavan ) Unique No (15975) Rate List Year (2024-2025) ITEM NO : 24 Providing and fixing on walls/ ceiling/ floors, 15 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings. remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. ( SSR Item No : 41.10 ) (PMC Bhavan ) Unique No (15792) Rate List Year (2024-2025) ITEM NO : 25 Providing and fixing on walls/ ceiling/ floors 20 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 1.93 Kilogram/meter with necessary fitting remaking good the demolished portion and applying primer of anti-corrosive oil paint, 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. ( SSR Item No : 41.11 ) (PMC Bhavan ) Unique No (15793) Rate List Year (2024-2025) ITEM NO : 26 Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SSR Item No : 41.12 ) (PMC Bhavan ) Unique No (15794) Rate List Year (2024-2025) ITEM NO : 27 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SSR Item No : 42.55 ) (PMC Bhavan ) Unique No (15907) Rate List Year (2024-2025) ITEM NO : 28 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SSR Item No : 42.56 ) (PMC Bhavan ) Unique No (15908) Rate List Year (2024-2025) ITEM NO : 29 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SSR Item No : 42.57 ) (PMC Bhavan ) Unique No (15909) Rate List Year (2024-2025) ITEM NO : 30 Building (Bd-V : Water supply and sanitory fittings)P.V.C. flexible Waste Pipe 32 mm dia SSR Item No : 49.V-74 ) (PMC Bhavan ) Unique No (17745) Rate List Year (2024-2025) ITEM NO : 31 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. SSR Item No : 33.34 ) (PMC Bhavan ) Unique No (15502) Rate List Year (2024-2025) ITEM NO : 32 Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab of approved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. a) One side polish ( SSR Item No : 33.32 ) (PMC Bhavan ) Unique No (15500) Rate List Year (2024-2025) ITEM NO : 33 Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover 75Kilogramwith lid and frame fixed in cement concrete. ( SSR Item No : 42.11 ) (PMC Bhavan ) Unique No (15863) Rate List Year (2024-2025) ITEM NO : 34 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75 Kilogram with lid and frame fixed in cement concrete. ( SSR Item No : 42.10 ) (PMC Bhavan ) Unique No (15862) Rate List Year (2024-2025) ITEM NO : 35 Providing and erecting chain link fencing 1.6 M. height with G. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/ with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete. ( SSR Item No : 46.39 ) (PMC Bhavan ) Unique No (16044) Rate List Year (2024-2025) ITEM NO : 36 Building (Bd-W : Water supply and sanitory fittings)Concentina Coil Wire ( SSR Item No : 49.W-09 ) (PMC Bhavan ) Unique No (18065) Rate List Year (2024-2025) ITEM NO : 37 Building (Bd-V : Water supply and sanitory fittings)Plastic Bucket ( SSR Item No : 49.V-101 ) (PMC Bhavan ) Unique No (17772) Rate List Year (2024-2025) ITEM NO : 38 Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. ( SSR Item No : 41.63 ) (PMC Bhavan ) Unique No (15838) Rate List Year (2024-2025) ITEM NO : 39 Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. ( SSR Item No : 42.30 ) (PMC Bhavan ) Unique No (15882) Rate List Year (2024-2025) ITEM NO : 40 Flat back urinal-providing and fixing flat back urinal without flushing tank but including bracket for fixing urinals,inlet pipe,32mm dia pvc flush pipe and stop tap ,filling the gaps with white cement etc complete ( SSR Item No : 61.04 ) (PMC Bhavan ) Unique No (16484) Rate List Year (2024-2025) ITEM NO : 41 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. ( SSR Item No : 42.20 ) (PMC Bhavan ) Unique No (15872) Rate List Year (2024-2025) ITEM NO : 42 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. ( SSR Item No : 42.67 ) (PMC Bhavan ) Unique No (15919) Rate List Year (2024-2025) ITEM NO : 43 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. ( SSR Item No : 39.9 ) (PMC Bhavan ) Unique No (15683) Rate List Year (2024-2025) ITEM NO : 44 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters SSR Item No : 42.53 ) (PMC Bhavan ) Unique No (15905) Rate List Year (2024-2025) ITEM NO : 45 Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. SSR Item No : 33.25 ) (PMC Bhavan ) Unique No (15493) Rate List Year (2024-2025) ITEM NO : 46 Providing and laying Vitrified mirror/glossy finish having decorative type of size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc . complete. SSR Item No : 33.58 ) (PMC Bhavan ) Unique No (15526) Rate List Year (2024-2025) ITEM NO : 47 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track sect ion 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. SSR Item No : 39.37 ) (PMC Bhavan ) Unique No (15711) Rate List Year (2024-2025) ITEM NO : 48 Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. ( SSR Item No : 36.03 ) (PMC Bhavan ) Unique No (15579) Rate List Year (2024-2025) ITEM NO : 49 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item Number 15 18 prior approval of Superintending Engineer will be necessary ( SSR Item No : 35.26 ) (PMC Bhavan ) Unique No (15576) Rate List Year (2024-2025) ITEM NO : 50 Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. ( SSR Item No : 35.09 ) (PMC Bhavan ) Unique No (15560) Rate List Year (2024-2025) ITEM NO : 51 Providing and applying French polish for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding etc. complete as directed ( SSR Item No : 34.05 ) (PMC Bhavan ) Unique No (15545) Rate List Year (2024-2025) ITEM NO : 52 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. ( SSR Item No : 34.09 ) (PMC Bhavan ) Unique No (15549) Rate List Year (2024-2025) ITEM NO : 53 Providing & fixing WOODEN FINISH/STONE Finish CEMENT PLASTER having Cement Mortar of 1:3 proportion with thickness 20 to 40 mm for wall, columns & beams, slab bottom/top or any surface. Rate includes Cement plaster of proportion 1:4 of wooden effect, after required curing, proper cleaning of surface by sand paper application of 1 coat of Apex exterior grade primer above that 2 coat of exterior grade Apex Paint as a base coat & 1 coat of Apex Paint for making wooden finish/grains & with 2 final coat of Apex clear polish including cement, Sand, chemical, adhesive, chikenmesh, paint, polish, paper, etc. all material, labor, scaffolding, etc. all complete. Work done should be as per a approved sample & the instructions of engineer incharge. SSR Item No : 1 ) (PMC Garden ) Unique No (19717) Rate List Year (2024-2025) ITEM NO : 54 PAINTING OF EXISTING WOODEN FINISH TEXTURED SURFACE at all heights including scaffolding etc. complete. Rate includes proper cleaning of surface by sand paper application of 1 coat of Apex exterior grade primer above that 2 coat of exterior grade Apex Paint as a base coat & 1 coat of Apex Paint for making wooden finish/grains & with 2 final coat of Apex clear polish including cement, Sand, chemical, adhesive, chikenmesh, primer, paint, polish, paper, etc. all material, labor, scaffolding, etc. all complete. Work done should be as per a approved sample & the instructions of engineer incharge. SSR Item No : 4 ) (PMC Garden ) Unique No (19720) Rate List Year (2024-2025) ITEM NO : 55 Providing & fixing BAMBOO FINISH RAILING IN CEMENT MORTOR of 1:3 proportion with appropriate thickness resembling bamboo of diameter 2½ to 3 inch. Railing clear Height 1.0m with underground support of minimum 0.45m depth of 1:1.5:3 ratio concrete of size 0.3 x 0.3 x 0.6m. vertical supports should be at min. 1.0 m intervals & with 10mm Tor steel 2nos in each horizontal member & 3nos in each vertical member. Railing will have two horizontal & two diagonal members in each panel. All external surfaces will have bamboo finish. Rate includes proper cleaning of surface by sand paper application of 1 coat of Apex exterior grade primer above that 2 coat of exterior grade Apex Paint as a base coat & 1 coat of Apex Paint for making wooden finish/grains & with 2 final coat of Apex clear polish including cement, Sand, chemical, adhesive, chikenmesh, primer, paint, polish, paper, etc. all material, labor, scaffolding, etc. all complete. Work done should be as per a approved sample & the instructions of engineer incharge. SSR Item No : 14 ) (PMC Garden ) Unique No (19730) Rate List Year (2024-2025) ITEM NO : 56 PROVIDING and laying Natural River Sand in Play Area or required locations in Gardens, as per the instructions given by the Engineer Incharge, inclusive of material, Labour, Transportation, , etc all complete. ( SSR Item No : 10 ) (PMC Garden ) Unique No (19726) Rate List Year (2024-2025) ITEM NO : 57 Providing and applying a base coat comprising of 1KilogramPolydee-MC and 1Kilogramfresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. ( SSR Item No : 31.11 ) (PMC Bhavan ) Unique No (15428) Rate List Year (2024-2025) ITEM NO : 58 Providing and laying polished hand cut Kotah Stone flooring 25mm to 30mm thick and 45cm to 55cm wide in plain/diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete. ( SSR Item No : 33.08 ) (PMC Bhavan ) Unique No (15476) Rate List Year (2024-2025) ITEM NO : 59 Providing Grouring by specially prepared grout of approved make Sq.m chemical with cement in proportion 135 (1 part chemical & 3.5 part cement by weight) along wih 50 ml super plasticizer non cracking antrwash high strength polymer cement grout PC grout available in bags or equivalent with proper water for injectable consistency and applying it in the body of structure like slab, beam, column, pillars, deckslab, retaining wall, basement, underground and elevated water storage reservoir concrete and brick wall, crack portion of structure etc. by injectng method, to achieve its original strength including drilling of suitable diameter drills holes at 2 to 4 Nos. per sqm. using caps and nozzle grouting machinery necessary, scaffolding, finishing and covering gurantee of 10 years on court stamp paper of Rs. 100/-and necessary testing etc. complete (Prior permission of S.E. in writing is necessary before inclusion of this item in estimate) ( SSR Item No : 52.28 ) (PMC Bhavan ) Unique No (16301) Rate List Year (2024-2025) ITEM NO : 60 Providing and laying yellow jaisalmare 25mm to 30mm thick and required width wide in plain/diamond pattern ona bed of 1:6 C.M. including cement float, filling joints, with neat cement slurry, curing, polishing and cleaning etc.complete. ( SSR Item No : 60.13 ) (PMC Bhavan ) Unique No (16474) Rate List Year (2024-2025) ITEM NO : 61 Building (Bd-V : Water supply and sanitory fittings)Brass nozzle pillar tap 12mm ( SSR Item No : 49.V-146 ) (PMC Bhavan ) Unique No (17817) Rate List Year (2024-2025)
Contract Date: May 19, 2026 Contract Value : 27.25 Lakh
Local Bodies No of Bidders 7
Maharashtra View Result →
41.
Defence #11104420 AOC
Tender For Repairs / Re-Novation Of Ofti And Ofti Work Shop Buildings Inside Factory Area At Ofmk.; 1 Site clearence 2 FELLING OF TREE: Felling of tree exc.30 cm and not exc.100 cm girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50m and clearing site 3 GRUBBING UP TREE TRUNK : Grubbing up tree trunk of girth exceeding 100 mm and not exceeding 150 mm, including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable materials and removing of unserviceable materials to a distance n. exc. 50 m and clearing site. 4 Demolition of cement concrete of any description and in any position not otherwise specifically provided for.Complete all as specified directed. 5 Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar. Complete all as specified directed. 6 Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Complete all as specified directed. 7 Dismantling floor,heartor wall tiling including cement mortar bedding but nor baking removing serviceable tiles to stores and rubbish off the premises.Complete all as specified directed and directed. 8 Taking down : Taking downcement or cement lime plaster, any description on brick or stone walls, etc.including raking out joints, hacking for key, scrubbing down with water, etc. 9 Removing building materials etc.other than spoilupto a distance of 1.0 Km, including loading, unloading and stacking at the destination. 10 Brick work with sub class ‘B’ bricks straight or curved in plan with 1:6 cement mortar.Complete all as specified and directed. 11 Stone Masonry : Walling of Squared Rubble regular coursed Stonemasonry, well bonded, bedded and solidly hearted built in with 1:6 cement mortar, Complete in all respects as specified and directed. 12 Damp proof course to horizontal or vertical surfaces In cement concrete 1:2:4, type B-0, 40 mm thickincluding necessary formwork . 13 Flush Pointing with 1:4 cement mortar to square rubble, coursed, well bonded and solidly hearted built in cement mortar as directed. 14 Vitrified tiles : Supply and laying of Light shade vitrified tiles 10 mm thick (Square/Rectangle) polished , area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Floor tile finishglossy/mat/ antiskid will be as decided by EIC. Complete all as specified and directed . Make : Johnson, Orient bell, AGL as approved by EIC. 15 GRANITE : S&F Granite 25 mm thk (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Complete all as specified and directed. 16 FLOOR TILING :Supply & fixing Coloured non skid ceramic tiles in flooring, 7 to 8 mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell 17 SCREED BED : Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:6. Complete all as specified and directed. 18 Plastering : Rendering of 10mm thick plastering with 1:6 cement mortar on fair faces of brick work or concrete surfaces. Complete in all respects as specified and directed. 19 Rounding to edges of stone slabs / granite one edge,such as in steps, cooking platform, and other similar situations. Complete all as specified and directed. 20 Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets etc. complete as directed by EIC. 21 Taking down wooden wall panelling of any description and similar work as directed. 22 Snap grid : Supply and fixing of 605x605 mm snap gridGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners withand including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediatechannel with connecting clips across the intermediatechannel at 457 mm centre to centre. Complete all as specifiedand directed, Make : Armstrong 23 Supply and fixing of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. 24 POP ceiling : Providing 10 mm thick plaster of Paris(gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mmwith 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately). Complete all as specifiedand directed, Make : Armstrong 25 Ceiling board : (M&L) S&F Exposed metal frame ceiling with calcium silicate boardof siliceous and calcareous material reinforced with cellulose fibre / PVC laminated gypsum tiles with MPL film on rear side, 8 mm thk.for fixing in 600 mm x 600mm grid,Make: Gyproc/ La gyp 26 Door shutter repair : Taking down door shutter of any description exc. 1 sqm and not exc. 2 sqmand repairing and adjusting to the required size including fixing builders hard ware and refixing to the same opening. complete all as specified and directed. 27 Dismantlingof structural steel work including doors, gates, but excluding framed truss etc. Complete all as specified directed. 28 UPVC window / Ventelator : Supply and fixing factory made UPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension . Complete all as specified and directed. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, 29 UPVC window : Three track three panels sliding window with fly proofS.S wire mesh (Two nos. glazed & one no. wire meshpanels) upto 1.50m height made of (big series) frame116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Areaof window above 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionof uPVC extruded glazing beads and uPVC extrudedinterlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy bodywith single nylon rollers (weight bearing capacity tobe 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steelscrews etc. Profile of frame & sash shall be mitred cutand fusion welded at all corners, including drillingof holes for fixing hardwares and drainage of wateretc. After fixing frame the gap between frame andadjacent finished wall shall be filled with weatherproof silicon sealent over backer rod of required sizeand of approved quality, complete all as specified anddirected by Engineer-in-Charge. 30 UPVC door : Supply and fixing factory made uPVC white colour Three track three panels sliding door with fly proofS.S. wire mesh (Two nos. glazed & one no. wire meshpanels) made of (big series) frame 116 x 45 mm & sash46 x 82 mm both having wall thickness of 2.3+ 0.2 mm and single glazing bead/ double glazingbead of appropriate dimension. (Area of door above2.00 sqm upto 5.00 sqm) comprising of uPVCchambered frame, with in-built roller track and sashextruded profiles duly reinforced with 1.60 + 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionuPVC extruded glazing beads, uPVC extrudedinterlock and uPVC extruded Inline sash adaptor (ifrequired), EPDM gasket, wool pile, zinc alloy (whitepowder coated) handle with key on one side of extremepanels along with zinc plated mild steel multi pointlocking having transmission gear with keeps, zincalloy (white powder coated) cresent lock (if required).stainless steel (SS 304 grade) body with adjustabledouble nylon rollers (weight bearing capacity to be120 kg), G.I fastener 100 x 8 mm size for fixing frameto finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut andfusion welded at all corners, including drilling ofholes for fixing hardwares and drainage of water etc.After fixing frame the gap between frame and adjacentfinished wall shall be filled with weather proof siliconsealent over backer rod of required size and ofapproved quality, complete all as specified anddirectd. 31 steel wire cloth : Supplying and Fixing in repairs stainless steel wire cloth0.36mm nominal dia.(Guage 28) of wire and width of aperture 1.4mm to wooden / steel doors/ windows, including fixing with and necessary screws, nut bolts,nails and removal of existing damaged cloth etc., complete all as specified and directed 32 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.0 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 33 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.8 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 34 Wooden Wall panelling : S & F of Prelaminated particle board18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work. Complete as specified and directed at site. 35 Wooden panelling frame work : S&F of battens frame work using wooden clean sawn 2nd class soft wood battens of cross sectional area exc. 15 & not exc. 25 sq.cm at a spacing of 35 centres. Complete as specified and directed at site. 36 PCC paving : PCC 1:4:8 in floors/ pavingoftype D-2, 1:4:8 with 40mm graded aggregate,100 mm thick.Complete all as specified and directed. 37 Earth work in excavation in all kind of soils by mechanical means (Hydraulic excavator) means over areas exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge 38 Soling (or sub base) of spread thickness 150 mm with broken boulders or quarried stone, inter sticesfilled, surface formed and rolled and consolidated torequired gradient and camber. Complete all as specified and directed. 39 Hard core with broken stone/boulders of gauge not exc. 63mm, deposited, spread leveled in layers not exceeding 15 cm thick, and watered consolidated to required gradient & camber including watering. Complete all as specified and directed. 40 Moorum filling in floors or pavings laid in layers not exe. 15cm thick , spread leveled and rammed including watering. Complete all as specified and directed 41 Stone sett flooring (M&L) with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 42 Edge stones to flooring (M&L) with stone setts of size 250 to 300mm long x l50 to 200mm wide, and 450mm deep and and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 43 PCC paving : PCC 1:2:4 in floors/ pavingoftype B-2, with 40mm graded aggregate, 100 mm thick. Including finishing concrete surface even and smooth surface without using extra cement.Complete all as specified and directed. 44 Wearproof topping 20 mm thick using CC 1:2:4, as specified incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner). Complete all as specified and directed. 45 Supply of metalic floor hardener 46 Surface excavation not exceeding 30 cm deepand averaging 20 cm deep in hard / dense soil and getting out. Complete all as specified and directed 47 PCC FLOORING : Cement concrete of 100 mm thickness in floors, sub-floors, sub-bases, pavings etc. oftype B-1, 1:2:4 (20 mm graded aggregate) 48 Smoth finish : Finishing cement concrete surface even and smooth using extra cement. 49 CC Paver blocks : S&F of Machine pressed precastconcrete interlocking paver block any shape and sizeconfirming to IS 15658-2006 of 60 mm thickness, M-35Grade with grey cement & pigment (Coloured)Complete all as specified and directed. 50 CC chequered tiles :S&F of cement concrete chequered tiles with grey pigment cement and pigments(Coloured tiles) for pavements. size of tile 20cm x20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors.Complete all as specified and directed. 51 PCC paving : PCC 1:3:6 in floors/ pavingof type C-2, with 40mm graded aggregate, 100 mm thick.Complete all as specified and directed. 52 Forming 12mm thick Expansion joints for 100 thick slabsfilled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A. ’ Complete all as specified and directed. 53 Structural steel (S&F) : Structural steel work confirming to Fe-410 W (Gde-E-250) quality-A Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled forfixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, including application of one coat of Zinc chromate primer paint .Make:TATA, Jindal 54 Structural steel (S&F) : Structural steel work Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Steel confirming to Fe410W (Gde E-250 quality A). Make : TATA, Jindal, Complete all as specified directed. 55 Structural steel (S&F) : Mild steel bolts. purpose made. of dia. of neck n.exc. 12 mm with hexagonal orsquare head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long. Complete all as specified directed. 56 Roofing sheet : Supply and fixing of pre painted galvalume aluminium zinc coating GI basedcorrugated/ trapezoidal profile roofing sheets of thickness 0.5 mm having tensile strength of 550Mpa as in roof covering / cladding to wall with self tapping screws etc. Make : TATA / Jindal /Essar. Complete all as specified and directed. 57 Supply only of liquid water proofing compound for incorporating concrete.Make. Fosrac, BASF, SIKA 58 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in in lintels upto 1.5m clearspan, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating. complete as specified and directed. 59 Kerb stone : Providing precast cement concrete using Type-B1, 1:2:4 20 mm graded aggregatein window or doorcills, lintels, bressumers, steps, quoin blocks (for use with ma- sonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets,etc. with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar 1:4. Complete with joints to match . Complete all as specified and directed. 60 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in roofkerbs or mud stops, rounded orchamfered on edges.complete as specified and directed. 61 PCC : Plain Cement Concrete (1:2:4) Type B2 using 40 mm graded aggregate in foundations, floors, filling and mass concrete, Complete all as specified and directed . 62 RCC : Reinforced cement concrete (Type B1, 1:2:4 with 20 mm aggregates) in columns, pillars, piers, posts etc. Complete all as specified and directed. 63 REINFORCEMENT : Mild steel(TMT) bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specified and directed. . 64 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 100 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 65 SWG PIPE : Supply & fixing of 100 mm dia Salt Glazed Stoneware drain pipes Grade A, including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 66 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 150 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 67 SWG PIPE : Supply & fixing of 150 mm dia Salt Glazed Stoneware drain pipeslaid in trenches including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 68 Earth work in excavation of all kind of soils by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Complete all as specified and directed . 69 Returning, filling in of excavated soils, including spreading, levelling, watering and well ramming in layersnot exc 25 cm. 70 PVC PIPE : Supply and Fixing of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid or fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 71 PVC PIPE : Supply and Fixing of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 72 Cutting chases in brick wall, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit iring, etc., and making good, cutting not exc 10 cm girth. Complete all as specified and directed. 73 Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat surfaces. Complete all as specified and directed. 74 S & F ofG.I. Tubes of Size 40 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 75 S & F ofG.I. Tubes of Size 25 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 76 S & F ofG.I. Tubes of Size 1/2‘’(15 mm), medium grade including all fittings to walls and ceilings or in floors/trenches. 77 Supply & Fixing Rotational moulded polyethylene water storage tanks (PVC cylindrical vertical with closed top) hoisted and fixed in position 1000 lit capacity. make : Syntex 78 BALL VALVES : 25 mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. Complete all as specified and directed. 79 NAHANI TRAPS : Supply & Fixing ofCI Nahani traps 100mm with grating including jointing to went pipe with CC 1:2:4complete all as specified and directed at site. 80 GULLY TRAP : M&L for PVC/SWR gully traps, of size 125 mm x 110 mm all as directed and specified. 81 GRATING : Supply and fixing of grating doom 100 mm dia. of PTMT (min. weight 25 gms) 82 PVC D/E PIPE CONNECTION :Supply and fixing of PVC Double End Pipe connection.in repairs, size:15mm with end nuts & washers of length 600 mm. Make : Kohinoor. Complete all as specified and directed. 83 ALUMINIUMPARTITIONS : Supply and fixing complete of anodised aluminium powder coated frames for partition frames and windows etc. all complete as directed by E.I.C. 84 ALUMINIUM WINDOW SHUTTERS : Supply and fixing complete of anodised aluminiumwindow and ventilator shutters powder coated fixed type without sash bar ,aluminium section weighing 0.55 kg/m including necessary jointig cleats, glazing clips, rubber neoprane packing, handles 2 nos. in each door, hinges, anodised aluminiumsnap beading, screws etc. complete all as directed by E.I.C. 85 HINGES : Supply and fixing of extruded Al. alloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-21 of size 125mmincluding all as specified and directed . 86 Antique aldrop : Supply and fixing of 200 mm long Antique model Brass mixed heavy alloy, sliding door bolt withsand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed.All as specified and directed and as approved by EIC. 87 Brass hinge: Supply and fixing of extruded brassalloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-11 of size 125mmincluding.All as specified and directed and as approved by EIC.. 88 Antique tower bolt : Supply and fixing of Antique model Brass mixed heavy alloy, barrel tower bolts of extruded section of size 200 mm and fixed all as directed.All as specified and directed and as approved by EIC. 89 Antique Door handle : Supply & fixing of Extruded Antique model Brass mixed heavy alloy, cast type polished bright handles 150 mm long, Complete all as specified and directed 90 TOWER BOLT : Supply and fixing of Aluminium anodised, barrel tower bolts of extruded section of size 200 mm and fixed all as directed. 91 BOW HANDLE: Supply & fixing of Extruded aluminium alloy handles 150 mm long, fabricated type, anodised. Complete all as specified and directed 92 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be easured separately), removing materials to store for keeping in safe custody for reuse at site and making good. 93 Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) 94 point wiring:S&F / Drawing of cables in PVC pipe,OneLight point or onefan point controlled by one switch with cables 1.5 sq.mm size of copper conductor cables FR PVC single core sheathed cable 95 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 5 amps independent, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 96 point wiring: S&F /Drawing of cables to One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 97 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 15 amps independent, with cables 4.0 sq.mm size of copper conductor cables FR PVC sheathed. 98 S & F of ceiling rose,3 phase/PVC/Polycorbonate, Isolate body 99 S & F ofswitch modular type of one module, 6 amps 100 S & F ofsocket, 2/3 pin combined, 6 amps, 2 Module 101 S & F ofswitch modular type of one module, 16 amps 102 S & F ofsocket, 2/3 pin combined, 16 amps, 2 Module 103 S & F ofFan step regulator 120 W, 2 Module 104 LED LUMINAIRE :Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/ Halonix 105 S & F of round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. 106 S & F of LED tube lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 107 LED Street Light :Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/Halonix.complete all as specified and directed 108 Exhaust Fan: Supplyand Fix Exhaust Fan made of sturdy Engineering plastic complete with Lauvers, Shutteers, voltage 230 V,50 HZ, RPM 1200, Copper winding ofsweep 250mm.complete all as specified and directed. 109 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) 110 Industrial socket plug: Supply and fixing of 240 V, 20 amps, single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB. 111 MCB :Supply and fixing of MCB / Isolator, 240 V, single pole 40 amp 112 MCB :Supply and fixing of MCB / Isolator, 240 V, double pole 40 amp 113 MCB D.B : S & F of Sheet Metal enclousers for D.B ofsingle doorof SPN,8 way with 200A rated bus bar,240V 114 MCCB: Suppply and fixing of MCCB 3 pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA. 115 S & F of Modular metal flush box 6 module 116 S & F of Modular white cover plate with frame 3 module 117 S & F of Modular white cover plate with frame 4 module 118 S & F of Modular white cover plate with frame 6 module 119 S & F of Modular white cover plate with frame 8 module 120 EARTHING : Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth lead GI strip 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.complete all as specified and directed 121 Earth continuity conductor : Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip. complete all as specified and directed 122 Dismantlng ofAsbestos cement (corrugated,semi corrugated, etc.) sheets in roofcoverings. Sheets shall be deposited to stores as directed. 123 Cutting or uprooting grass on old CC/brick tiles or on old mud phuska,and Taking down old Taf felt and loose material from the roof, cleaning the bitumen surface by wire brushing, washing down & disposing the pealed off tar felt muck etc. for complete as directed. removing rubbish off the premises, cleaning surface and preparing to receive new mud plaster. Complete as specified and directed. 124 Surface painting : Removal of old tarfelt sheets,Wire brushing and cleaning top surface of roof tops and surface painting, with a layer of bitumen primer for bitumen membrane @ 0.50 ltr/sqm by the same membrane manufacturere of density at 25° C, 0.87-0.89 Kg/ltr and viscosity 70-160 cps and then left the surface 4 to 8 hours for drying.Complete as specified and directed. 125 Bitumen Tack coat / Seal coat : Applying surface bitumen coat Seal / Tack coatwith lndustrial bitumen 85/25 forwaterproofingtreatments at the rate of 1.2 kg / sqm . 126 Water proofing treatment (M&L) : Rendering water proofing treatment to RCC roof slabs including vertical surfaces with APP based polymetric membrane sheet, minimum 3 kg/sqm and minimum 3.0 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) evenly laid on primed surfaces by forced applicationby torch on treatment. The vital physical and chemical parameters of the membrane shall be : Tensile strength in longitudinal and transverse direction at 23° C as 650/450/5 cm.Tear strength in longitudinal and transverse direction as 300/250 N. Softening point of membrane not less than 150° C. Cold flexibility shall be up to 2° c when tested in accordance with ASTM, D-5147. The laying of membrane shall be done through the authorised applicator of the manufacturer of membrane. Membrane make : STP / Dr. Fixt / IWL as approved by EIC. 127 Carrying and disposal of debris : Removing building materials etc. to a distance of 1.5 KM or under including loading, unloading and stacking at the destination. Complete all as specified and directed at site. 128 Rolling shutter : S&F ofSteel rolling shutters 1.25 mm thickness of lathe, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle. Complete all as specified and directed. 129 Rough excavation notexceeding1.5 m deepin drains etc in loose/soft soils andgetting out 130 Scarifying : Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exc.400 sqm and the thickness Exc 50 mm and n.exc 100 mm deep 131 Preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 132 Macadam : Premix bituminous, macadam with paving bitumen any penetration laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less).Complete all as specified and directed. 133 Pot holes : Repair to pot holes any depth, not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth,making good by applying tack coat @ 5 kg per 10 sq m, putting in premixed bituminous macadamusing paving bitumen, well rammed and sealed with binder 9.8 kg per 10 sq m, blinded with 0.09 cu m of stone chippings,6.3 mmsizeand again well rammed (including supply of premixed macadam, binder and chippings). depth of potholes exc 30 mm.Complete all as specified and directed. 134 Preparing Black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 135 Applying evenly a priming/tack coat with bituminous primer using paving bitumen at 5kg per 10 sq metre. Complete as specifiedand directed. 136 Bituminous premixed carpet, 2.5 cm consolidated thickness, with 0.34 cu.m. of stone chippings mixed with 18.25 kg of binder (paving bitumen)per 10 sq.m and mixed in mechanical hot mix plant and laid with mechanical paver and rolled using power roller 8-10 T capacity and compacted to required camber and gradient to uniform smooth surface. Complete as specifiedand directed. 137 Supply and fixing of Machine cut cudappah stoneslab 20-25mm thick over cementscreed base, laid and jointedwith grey cement slurry mixedwith pigment to match the shadeof the slab including rubbingand polishing complete. 138 Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint and application of priming paint plaster coat. 139 Rendering synthetic enamel painting on new Steel surfacesof any description over 10 cm width or girth- TWO coats including one coat of red oxide Zinc chrome paint. Make: Asian paints/Berger 140 Complete removal existing treatment of of white washing onsurfaces of walls/ concrete. 141 Complete removal existing treatment of of white washing on surfaces of ceilings. 142 CHALK WHITENING : M&L - Chalk whitening (white cement-based, water-resistant, white wall putty) of plastered surfaces as preparatory to distempering on wall surfaces, Make : Birla wall care, complete all as specified & directed. 143 PRIMER : Priming plastered and other surfaces with alkali resistant priming paint. Make : Asion/Dulux- all as specified and directed . 144 WHITEWASH ON CEILINGS : M&L - White washing on ceilings- on old decorated surfaces- including preparation of surfaces – ONE coat of White Wash-complete all as directed. 145 WHITEWASH ON WALLS : M&L - White washing on Walls – on old decorated surfaces- including preparation of surfaces - TWO coats of White wash - complete all as directed. 146 PLASTIC EMULSION PAINT:Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint-complete all as directed. Make: Asian -Apcolite / Dulux-promise. 147 OBD : M&L - Rendering Oil Bound Distempering on old surfaces -including preparation of surfaces on walls - TWO Coats of OBD - complete all as directed. Make : Asian-tractor Uno / Berger-Butterfly / Indigo-gold. 148 External weather proof painting on walls : Material & Labour for applying Two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces. all as specified and directed, Brand : Asian apex,Berger weather shield, Nerolac Rain coat. 149 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting onOld painted Steel surfaces- surfaces of any description over 10 cm width or girth including preparation of surfaces-TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 150 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on Old painted Steel surfaces- surfaces of any description n.exc 10 cm width or girth including preparation of surfaces- TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 151 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on wooden surfaces - old surfaces of any description over 10 cm width or girth including preparation of surface - TWOCoats- all as specified and directed-Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 152 FRENCH POLISHING : French polishing on old surfaces of any description, width or girth –including cleaning and preparing the surface- One or more coats. all as specified and directed. Make : Sheenlac, sealer 153 Supply and fixing of Safety lever locks mild steel with 4 levers for rolling shutters as directed. 154 Fan Hook: Supply and Fixing of Fan hook with double anchor bolt complete fixing as per instructions of EIC. 155 IWC : IWC of approved make fixed with P trap Make: Hindware/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 156 CONCEALED FLUSHING SYSTEM : Wall mounted concealed flushing system (including frame, control plate and installation kit) with dual flush mode of capacity 10 ltrs. Make: Jaquar(Solo)/ Parryware(Prime)/ Cera(Fountain). Complete all as specified and directed. 157 MIRROR : Mirror 5 mm thk. with bevelled edge fixed with concealed screws Make: Saint Gobain/ Nilkamal/ Casa Gold. Complete all as specified and directed. 158 Switch board box with frame plate and cover plate , metal flush box18 module: Supply and Fixing of covering plates with Metal Flush box andcover plate frames of 18 module of make Legrand/ Schneider/ Havellscomplete all as specified by the EIC 159 Concertina coil & 6 straight RBT strands : Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina cross type fencing, GI steel plate & GI core wireon wall top using concertina coils stretched to approx.6 meters length at site and clipped with three nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as C clips, R.B.T clips etc.). Including additional three horizontal R.B.T strands to be fixed with vertical portion of MS angle supports as directed in site. Complete all as specified and directed at site. 160 Accoustic sheets : supply and fixing of choice colourPolyester Fiber Acoustic Board / tiles, Thickness: 12mm, for insula-tion and accoustic purposes, 60x60 cm in size, fixed to wall / ceiling surfaces on snap grid orwith nails to timber frame work or with Z bar/clips etc as specified by manufacturer.Complete all as specified and directed. 161 Floor mat: supply and fixing of choice colourNylon carpet for floors minimum 6 mm thicknesshaving better accoustic co-efficient ,fixed to floor with approved adhesiveas specified by manufacturer.Complete all as specified and directed. 162 ACP wall lining : Supply and fixing of decorative choice colour solid finished Aluminum composit panel 4.0 mm thick sheeting on external wall surfaces upto 12.0 mter heights fixed over aluminium/MS framed wall surfaces as specified by manufacturer. Cost includes ACP panel, frame work, jointing glue and scafolding etc. Complete all as specified and directed. 163 UPVC window (Single glazed panel shutter & fixed wire mesh panel): Supply and fixing factory made uPVC white colour Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series)frame 47 x 50 mm & sash 47 x 68 mm both havingwall thickness of 1.9 ± 0.2 mm and single glass paneglazing bead of appropriate dimension (Area ofwindow upto 0.75 sqm.) comprising of uPVC multi-chambered frame, sash and mullion (where everrequired) extruded profiles duly reinforced with1.60 ± 0.2 mm thick galvanized mild steel sectionmade from roll forming process of required length(shape & size according to uPVC profile), uPVCextruded glazing beads of appropriate dimension,EPDM gasket, stainless steel (SS 304 grade) frictionhinges, zinc alloy (white powder coated) casementhandles, G.I. fasteners 100 x 8 mm size for fixingframe to finished wall, plastic packers, plastic capsand necessary stainless steel screws etc. Including SS wire mesh panel with aluminium beeding fixed to outer face window using adjustable /removable clips. Profile offrame & sash shall be mitred cut and fusion weldedat all corners, mullion (if required) shall be alsofusion welded including drilling of holes for fixinghardwares and drainage of water etc. After fixingframe the gap between frame and adjacent finishedwall shall be filled with weather proof siliconsealant over backer rod of required size and ofapproved quality, complete all as specified anddirected by Engineer-in-Charge. 164 WALL TILES : Supply & fixing of Coloured digital glazed ceramic tiles in vertical surface 300x600 mm set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell. 165 PVC door frame : S & F of solid WPVC Door Frame of size 100x60 mm heavy density of 11100 kg/cum and high quality PVC laminated of choice colour. Complete all specified and directed. 166 PVC door shutter : S & F of Factory Made Solid WPVCDoor Shutter with wood free EPS, 32 mm thick, heavy density 700 kg/cum and high quality PVC laminated on both side of choice colour. 167 Staircase railing : Supply and fixing of designed Stainless steel hand railing not less than 0.8 mtr height for stairs, balconies etc. using SS grade 304/316 members for balusters & rails etc. and covered with 12 mm thick tampered toughned glass. Design & model shall be as decided by EIC. Cost inclusive of glass, design and other mountings. Complete all as specified and directed. 168 Handicap grab bar : S&F of stainless steel anti slip vertical swing handicap bath room grab bar/rail with paper holder of min. 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 169 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 170 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 0.45 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 171 Wood Door : Supply and fixing of modern & designer soildTeakwood door shutters for Main Doors 32 mm finished thickness as decided by EIC . 172 EWC : Supply and fixing ofItalian Collection ceramic Floor Mount Western Commode, Rim less, One-piece for Bathrooms with Syphonic vortex Flushing system and soft closing seat cover including connection pipe.Make : Jaquar Fusion, Hindware Fabio, Cera cinova 173 WASH BASIN : Supply and fixing of Under counter Wash basin rectangle of approved make along with waste coupling, waste pipe and connection pipe, brackets etc. Make : Jaquar(Continental)/ Cera(campa)/ Parryware(Aqiline). Complete all as specified and directed. 174 URINAL : Supply and fixing ofSensor Urinal pan of approved make with auto flushing system including connection pipe, waste coupling and waste pipe Make: Jaquar(Aquisense)/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 175 PILLAR COCK : S&F ofsensorbased table top model Pillar cock with auto closing system of make: Jaquar / Hindware/ Cera. Complete all as specified and directed. 176 CONCEALED STOP COCK : S&F of CP Concealed stop cock of make : Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 177 2 WAY ANGLE COCK : S&F ofCP 2 way angle cock Make: Parryware(Uno)/ Cera(Fountain)/ Jaquar(Solo). Complete all as specified and directed. 178 EWC JET FAUCET : S&F of EWC jet faucet of make: Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 179 BIB COCK : S&F ofCP Bib cock of make: Jaquar(Solo)/Parrywaare(Uno)/ Cera(Fountain). Complete all as specified and directed. 180 SOAP DISH : S&F of SS soap dish of make Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 181 Hand drier: Supply and fixing of plastic Automatic Hot air drierfor bath rooms of approved make. Make :Orchid / Dolphy / Bajaj. Complete all as specified and directed. 182 Liquid soap dispensar: Supply and fixing of Liquid soap dispensar for bath rooms of approved make. Make :Jaquar / Orchid / Dolphy. Complete all as specified and directed. 183 Toilet paper holder: Supply and fixing of stainless steel single toilet paper roll holder of approved make. Make :Jaquar continental / Parryware sigma/ Cera Icon. Complete all as specified and directed. 184 Urinal partition : Supply and fixing of HPL (High-Pressure Laminate) urinal partitions using 12 mm thick compact board of width 400 to 500 mm and height 1200 mm of approved make and fixing with stainless steel brackts. Complete all as specified and directed. 185 Bldg.Expansion joint : Preparation of joint by grinding of groove surfae, remoal of dust, providing polymer mixed cement mortar on both sidea of groove and crack filling if any in floor level, fixing of baker rod 25x25 mm to control depth of groove, Providing and applying Nitoseal PU50 of Fosroc or equivalant having MAF 25% or above to the groove 25x12 mm. Including fixing / covering of joint with APP based polymetric membrane sheet sufficient width. Complete all as specified and directed at site. 186 Forming V grooves on granite surfacesn,exc 10mmdeep and n exc 10mm on face in steps, cooking platform, and other similar situations etc. 187 Hiring / Engage of JCB for cleaning, moving and loading materials like sand, gravel, or demolitionand removal of debris and other miscellaneous purposes as directd. The rate includes diesel and driver required to run the vehicle. 188 Carpet grass : Supplly and laying of carpet grass on levelled soil surface including preparing the soil bedby loosning the base ground 100 mm thick and removing old unwanted grass if any and necessary watering as directed. 189 Supply and laying of red earth / soil in loose state which is free from debris, grass and other vegitation to be used for gardening purposes as directed. 190 Architectural design : Before commencement of work Contractor should take architectural consultancy servies for entrance arch at the entrance gate, building front elevations and garden designs by authorised institutions / authorised Designer. Complete all as directed by EIC
Contract Date: May 16, 2026 Contract Value : 3.98 Crore
Government Departments No of Bidders 4
43.
Defence #11088125 AOC
Tender For Comprehensive Maintenance And Repair To Certain B/R Works For Zone 1 And Zone 2 At Mil Stn Gandhinagar - Taking Down Shutter Of Any Description Exceeding 1 Square Metre And Not Exceeding 2 Square Metre Each Complete All As Specified And As Directed. Taking Down Chowkhat Or Frame (Without Taking Off Shutter From The Frame) Not Exceeding 1.5 Square Metre Each , Removing From The Site Including Cutting Holes Required For Taking Out Existing Hold Fast Etc. Complete All As Specified And As Directed. Taking Down Chowkhat Or Frame (Without Taking Off Shutter From The Frame) Exceeding 1.5 Square Metre And Not Exceeding 04 Square Metre Each , Removing From The Site Including Cutting Holes Required For Taking Out Existing Hold Fast Etc. Complete All As Specified And As Directed. M&L Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawing Complete All As Specified And As Directed. M&L For Framed/Chowkat Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Sheet, Braces Incl Fastner, Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings Running Rails And Guides And Hanging; Also Fastening And Fixing Complete All As Specified And As Directed. S&F Factory Made Solid Panel Pvc Door Shutter 30Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc `C Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded/ Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And As Directed. S&F Factory Made Solid Pvc Moulded Door Shutter With Particle Board , 28 To 30Mm Thick (Stiles), With 2, 4, Or 6 Raised Panel Design With 2Mm Thick Moulded Prelam Pvc Sheet On The Front Face & 2Mm Prelam Pvc Sheet On Back Face Supplying & Fixing In Frame At Site As Per Specification & Drawing Complete All As Specified And As Directed. S&F 35Mm Thick Iind Class Hard Wood Panelled Door Shutter With Lock Rail And Panel Of 9Mm Bwp Commercial Ply Or 12Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rail And Stiles As Per Is: 1003 (Part-I), Kiln Seasoned And Chemically Pressure Treated And Fixed To Chowkats Complete. S&F 35 Mm Thick Iind Class Hard Wood Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze, Etc. (Without Sash Bars), Edge Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitred Beds For Securing Glass, Etc.; Sizes Of Members Of Shutters As Specified In Ssr Part I, Section 8. Clause 8.20 (A); Supplied And Fitted To Chowkats Complete All As Specified And As Directed. M&L For 30Mm Thick Flush Shutter Solid Core Construction With Block Board Core And Ply Wood Face Panels, Commercial Type On Both Side Prelam Laminated Sheet And Side Bedding Complete Etc Compete All As Specified And Directed By Engr-In-Charge. S&F Providing And Fixing Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) Work For Three/Two Tracks Shutters/ Frames/Grills For Doors, Windows, Ventilators And Partitions (Fixed Portions), Slinding Windows,Ventilators Including Providing And Fixing Hinges/ Pivots/Rollers And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately) With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.P. Brass/ Stainless Steel Screws All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. 12 M&L For Preparing Of New Untreated Wooden Surfaces Of Any Description Not Otherwise Described Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint (Of Approved Shade) Over A Coat Of Pink Primer Complete All As Specified And As Directed. 13 M&L Painting To New Or Previously Untreated Steel Surfaces Of Any Description Over 10Cm In Width Or Girth With Two Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromic Primer Including Preparation Of Surfaces Complete All As Specified And As Directed. 14 Supply And Fixing Stainless Steel Hinges 100Mm Long Medium Weight To Pressed Steel/Angle Iron Frames By Welding/Screws Complete All As Specified And As Directed. 15 S&F Aluminium Anodised Barrel Tower Bolt 150Mm Size Extruded Section, Isi Marked & Fixed 16 S&F Aluminium Anodised Barrel Tower Bolt 200Mm Size Extruded Section, Isi Marked & Fixed Complete All As Specified And As Directed. 17 S&F Extruded Aluminium Alloy Handles 150Mm Size Fabricated Type Anodised. Isi Marked Complete All As Specified And As Directed. 18 S&F 300Mm Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp ,Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified And As Directed.
Contract Date: May 29, 2026 Contract Value : 42.55 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
44.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
47.
Housing Urban and Rular Development #11053840 AOC
Tender For Annual Repair Special Repair /Mow Works In Various Rb/Nrb Under Section No.7, Jail Sub Division No.1, Bhopal- 1 Ar/Sr/Mow Works In Various Rb/Nrb Under Section No.7, Jail Sub Division No.1, Bhopal 1St Call P.A.C. 40.00 Lakh,As Per Building Sor Wef 01-01-2024 Schedule Attached Complition Period 180 Days Please Enable Macros To View Boq Information Ar/Sr/Mow Works In Various Rb/Nrb Under Section No.7, Jail Sub Division No.1, Bhopal Building Sor Wef 01.01.2024 Probable Amount Of Contract - Rs. 40.00 Lakh S.No Description Qty. Unit Rate Amount 2 2.1 All Kinds Of Soil. 100 Sqm 803.0 3 2.6 All Kinds Of Soil Cum. 147.0 4 2.7 2.7.1 Ordinary Rock Cum. 287.0 2.7.2 Hard Rock (Requiring Blasting) Cum. 519.0 2.7.3 Hard Rock (Blasting Prohibited) Cum. 828.0 5 2.25 2.25.1 All Kinds Of Soil. Cum 30.0 2.25.2 Ordinary Or Hard Rock. Cum 53.0 6 2.27 2.27.1 With Hard Muram Having Cbr >12 % At Under Floors Including Watering, Ramming And Compacting (Minimum Compaction 95% Of Mdd) In Layers Not Exceeding 20Cm In Thickness And Dressing Complete. (Note:- Maximum Thickness Of This Layer To Be Provided Shall Be 30Cm) Cum 393.0 2.27.2 Supplying And Filing In Plinth With Soil (Other Then Bc Soil ) Having Mdd Not Less Than 1.85 T/M3 Under Floors Including Watering, Ramming And Compacting (Minimum Compaction 95% Of Mdd) In Layers Not Exceeding 15Cm Depth And Dressing Complete. Cum 331.0 7 4.1 4.1.1 With 20Mm Nominal Size Graded Stone Aggregate. 4.1.1.1 M-25 – Grade Concrete Cum 6338.0 4.1.1.2 M-20 – Grade Concrete Cum 4933.0 4.1.1.3 M-15 – Grade Concrete Cum 4471.0 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 Sand : 6 Graded Stone Aggregate ) Cum 3890.0 4.1.2 With 40Mm Nominal Size Graded Stone Aggregate. 4.1.2.1 M-15 - Grade Concrete Cum 4403.0 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate) Cum 3808.0 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 Sand : 8 Graded Stone Aggregate Cum 3474.0 4.1.3 With Fly Ash. 4.1.3.1 1:2½:4:11 (1 Ordinary Portland Cement : 2½ Fly Ash : 4 Sand : 11 Graded Stone Aggregate 40 Mm Nominal Size) Cum 3459.0 4.1.3.2 1:2½:4:11 (1 Ordinary Portland Cement : 2½ Fly Ash : 4 Sand : 11 Graded Stone Aggregate 40 Mm Nominal Size) Cum 3150.0 Note: No Fly Ash Is To Be Added To Portland Pozzolona Cement In Any Case Which Itself Contains Fly Ash. 8 4.2 4.2.1 With 20Mm Nominal Size Graded Stone Aggregate 4.2.1.1 M-25 – Grade Concrete Cum 6582.0 4.2.1.2 M 20 – Grade Concrete Cum 5177.0 4.2.1.3 M 15 – Grade Concrete Cum 4714.0 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 4134.0 4.2.2 With 40Mm Nominal Size Graded Stone Aggregate 4.2.2.1 M-15 - Grade Concrete Cum 4647.0 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 4052.0 9 4.3 4.3.1 Upto Plinth: Foundations, Footings, Bases For Columns, Plinth Beams, Curtain Walls, Columns Below Plinth. Sqm 169.0 4.3.2 Above Plinth: Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Buttresses, And String Courses Fillets Etc. Sqm 267.0 4.3.3 Above Plinth: Columns, Pillars, Posts And Struts. Sqm 356.0 10 4.4 4.4.1 M-15 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 4471.0 4.4.2 M-10 (With 20Mm Nominal Size Graded Stone Aggregate) Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 3890.0 11 4.6 4.6.1 M-25 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 5095.0 4.6.2 M-20 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 5558.0 4.6.3 M-15 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 5095.0 4.6.4 M-10 (With 20Mm Nominal Size Graded Stone Aggregate) Nominal Mix -1 Cement: 3 Sand: 6 Graded Stone Aggregate. Cum 4515.0 12 4.7 4.7.1 M-15 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 7057. 00 4.7.2 M-10 (M 10) (With 20Mm Nominal Size Graded Stone Aggregate) Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 6477.0 13 4.15 Note For Item No. 4.15:- The Quantity Will Be Calculated By Multiplying The Depth Measured From The Sub-Soil Water Level Upto Centre Of Gravity Of Concrete Under Sub-Soil Water Level With Quantity Of Concrete In Cum Executed Under Sub-Soil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1M. 0.05M Or More Shall Be Taken As 0.1M And Less Than 0.05M Ignored. Cum 109.0 14 5.1.1 5.1.2 M-15 Grade Concrete Cum 5397.0 5.2 Reinforced Cement Concrete Work (With 20 Mm Nominal Size Graded Stone Aggregate) In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Posts And Struts Etc. Above Plinth Level And Upto Floor Two Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement: 15 5.2.1 5.3 Reinforced Cement Concrete Work (With 20 Mm Nominal Size Graded Stone Aggregate) In Beams, Suspended Floors, Roofs Having Slope Of Any Degree Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Staircases Above Plinth Level And Upto Floor Two Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement In Concrete Grade. 16 5.3.1 5.4 Providing And Laying Upto Floor Two Level Reinforced Cement Concrete (With20 Mm Nominal Size Graded Stone Aggregate) In Kerbs, Steps And The Like Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With Concrete Grade. 5.4.1 M-20 Grade Concrete Cum 5542.0 17 5.9 5.9.1 Foundations, Footings, Bases Of Columns, Etc. For Concrete Upto Plinth Level Sqm 190.6 5.9.2 Walls (Any Thickness) In Cluding Attached Pilasters Butter Esses, Plinth Beams And String Courses Etc. 5.9.2.1 Uptoplinthlevel. Sqm 219.0 5.9.2.2 Above Plinth Upto 3.6 M Height From Plinth Level Sqm 330.0 5.9.2.3 Extra For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De-Shuttering And Decentering At All Levels, Over A Height Of 3.6 M, For Every Additional Height Of 1 Metre Or Part Thereof. Sqm 40.0 5.9.3 Suspended Floors, Roofs, Landings, Balconies And Access Platform. Sqm 439.6 5.9.4 Shelves(Cast In Situ) Sqm 290.0 5.9.5 Lintels, Beams, Girders, Bressumers And Cantilevers Sqm 356.0 5.9.6 Columns, Pillers , Piers, Abutments, Sqm 471.2 Posts And Struts. 5.9.7 Stairs, (Excluding Landings) Except Spiral- Staircases. Sqm 435.7 5.9.8 Spiral Staircases (Including Landing). Sqm 450.0 5.9.9 Arches, Domes,Vaults Upto 6M Span Sqm 1141.6 5.9.10 Extra For Arches, Domes, Vaults Exceeding 6 M Span Sqm 451.3 5.9.11 Chimneys And Shafts Sqm 294.0 5.9.12 Coffer/Waffle Slab Of Any Size Or Shape As Shown In The Drawing. Sqm 1481.0 5.9.13 Well Steining Sqm 264.0 5.9.14 Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards. Sqm 643.4 5.9.15 Extra For Shuttering In Circular Work Or Any Other Geometrical Shape (20% Of Respective Centering And Shuttering Items). Sqm 0.2 5.9.16 Small Lintels Not Exceeding 1.5M Clear Span, Mouldingas Incornices, Window, Sills, Courses, Bands, Copings, Bed Plates, Anchor Blocks And The Like. Sqm 191.0 5.9.17 Cornices And Mouldings Sqm 565.0 5.9.18 Small Surfaces Such As Cantilever Ends, Brackets And Ends Of Steps, Caps And Bases To Pilasters And Columns And The Like. Sqm 529.6 5.9.19 Weather Shade, Chajjas, Corbels Etc., Including Edges. Sqm 534.2 5.9.20 Suspended Floors, Roofs, Landings, Balconies And Access Platform. With Water Proof Ply 12 Mm Thick. (Item To Be Executed With Prior Permission Of S.E. In Case Of B & R Works And From Additional Project Director In Case Of Piu Works) Sqm 575.35 5.9.21 Lintels, Beams, Columns, Girders, Bressumers And Cantilevers With Waterproof Ply 12 Mm Thick (Item To Be Executed With Prior Permission Of S.E. In Case Of B&R Works And From Additional Project Director In Case Of Piu Works) Sqm 521.2 18 5.1 5.10.1 Suspended Floors, Roofs, Landing, Beams And Balconies (Plan Area To Be Measured). Sqm 212.0 19 5.12 5.12.1 50 Mm Thick Sqm 790.0 5.12.2 40 Mm Thick Sqm 689.0 5.12.3 25 Mm Thick Sqm 598.0 20 5.16 (Note:- (1). Spacer Bars (Chairs) Shall Be Paid Separately As Shown In The Drawing And As Per Direction Of Engineer In Charge. (2). No Extra Payment Shall Be Done For Overlaps And/Or Couplers. (3). Couplers Shall Be Conforming To Is Code On “Reinforcement Couplers For Mechanical Splices Of Bars For Concrete Reinforcement - Specification”) 5.16.1 Mild Steel And Medium Tensile Steel Bars. Kg 78.0 5.16.2 Hard Drawn Steel Wire Kg 75.0 5.16.3 Cold Twisted Bars (Ctd) Kg 81.0 5.16.4 Hot Rolled Deformed Bars Kg 81.0 5.16.5 Hard Drawn Steel Wire Fabric Kg 76.0 5.16.6 Thermo-Mechanically Treated Bars. (Tmt/Tmx) Fe 500 Or More Conforming To Is 1786 Kg 80.0 21 5.22 5. 22.1 12 Mm Thick Sqm 402.0 5. 22.2 25 Mm Thick Sqm 574.0 5. 22.3 50 Mm Thick Sqm 674.0 22 5.23 5. 23.1 Non-Asbestos Fibre Cement Board 6 Mm Thick As Per Is: 14862. 5. 23.1.1 150Mm Wide. Rm 102.0 5. 23.1.2 200Mm Wide. Rm 137.0 5. 23.1.3 250Mm Wide. Rm 153.0 5. 23.2 Aluminium Fluted Strips 3.15Mm Thick. Rm 483.0 5. 23.2.1 150 Mm Wide. Rm 646.0 5. 23.2.2 200 Mm Wide. Rm 725.0 5. 23.2.3 250 Mm Wide. 5. 23.3 Stainless Steel Grade 304 Plate-1.0 Mm Thick 5. 23.3.1 150 Mm Wide. Rm 367.0 5. 23.3.2 200 Mm Wide. Rm 443.0 5. 23.3.3 250 Mm Wide. Rm 555.0 23 5.25 Note- For Item No. 5.25:-The Quantity Will Be Calculated By Multiplying The Depth Measured From The Subsoil Water Level Up To The Centre Of Gravity Of The R.C.C. Under Ubsoil Water With The Quantity Of R.C.C. In Cubic Metre Executed Under Subsoil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1 M. 0.05 M Or More Shall Be Taken As 0.1 M And Less Than 0.05 M Ignored. No Extra Payment Shall Be Made For Placing Reinforcement Or Centering & Shuttering Under Sub – Soil Water Condition 24 5.33 5. 33.1. Frame 125 Mmx 60 Mm (Double Rebate) Rm 366.0 5. 33.2. Frame 100Mmx 60 Mm (Single Rebate) Rm 339.0 5. 33.3 Frame 85Mmx 60 Mm (Single Rebate) Rm 325.0 25 6.1 6.1.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5818.0 6.1.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5626.0 26 6.2 6.2.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 6012.0 6.2.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5821.0 27 6.3 6.3.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5252.0 6.3.2 Cement Mortar 1:6 (1 Cement:6 Sand). Cum 5061.0 28 6.4 6.4.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5446.0 6.4.2 Cement Mortar 1:6 (1 Cement:6 Sand). Cum 5255.0 29 6.5 6.5.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 4347.0 6.5.2 Cement Mortar 1:6 (1 Cement: 6 Sand). Cum 4155.0 30 6.6 6.6.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 4541.0 6.6.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4350.0 31 6.7 6.7.1 Having 100 Kg / Cm2 Average Compressive Strength. 6.7.1.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5384.0 6.7.1.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5162.0 6.7.2 Having 75 Kg / Cm2 Average Compressive Strength. 6.7.2.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5271.0 6.7.2.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5049.0 6.7.3 Having 50 Kg / Cm2 Average Compressive Strength. 6.7.3.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5158.0 6.7.3.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4936.0 32 6.11 Providing Half Brick Masonry With Well Burnt Chimney Bricks In Bull Patent Trench Kiln Manufactured By Ghol Process Crushing Strength Not Less Than 40 Kg /Cm2 And Water Absorption Not More Than 15% In Superstructure Above Plinth Level And Up To Floor Two Level. 6.12.1 Cement Mortar 1:3 (1 Cement : 3 Sand) Sqm 697.0 6.12.2 Cement Mortar 1:4 (1 Cement : 4 Sand) Sqm 673.0 33 6.13 6.13.1 Cement Mortar 1:3 (1 Cement : 3 Sand) Sqm 639.0 6.13.2 Cement Mortar 1:4 (1 Cement : 4 Sand) Sqm 615.0 34 6.14 6.14.1 Cement Mortar 1:3 (1 Cement : 3 Sand) Sqm 546.0 6.14.2 Cement Mortar 1:4 (1 Cement : 4 Sand) Sqm 522.0 35 6.15 6.15.1 Having 100 Kg/Cm2 Average Compressive Strength. 6.15.1.1 Cement Mortar 1 : 3 (1 Cement : 3 Sand) Sqm 570.0 6.15.1.2 Cement Mortar 1 : 4 (1 Cement : 4 Sand) Sqm 551.0 6.15.2 Having 75 Kg/Cm2 Average Compressive Strength. 6.15.2.1 Cement Mortar 1 : 3 (1 Cement : 3 Sand) Sqm 524.0 6.15.2.2 Cement Mortar 1 : 4 (1 Cement : 4 Sand) Sqm 505.0 6.15.3 Having 50 Kg/Cm2 Average Compressive Strength. 6.15.3.1 Cement Mortar 1 : 3 (1 Cement : 3 Sand) Sqm 479.0 6.15.3.2 Cement Mortar 1 : 4 (1 Cement : 4 Sand) Sqm 459.0 36 6.24 Note: - The Quantity Will Be Calculated By Multiplying The Depth Measured From Sub - Soil Water Level Up To The Centre Of Gravity Of Brick Work Under Sub - Water With The Quantity Of Brick Work In Cum Executed Under The Sub - Soil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1 M. 0.05 M Or More Shall Be Taken As 0.1 M And Less Than 0.05 M Ignored. 37 6.27 6.27.1 Aac Masonry In Polymer Modified Mortar Cum 5052.0 38 6.29 Of Minimum 80 Mmwidth And Depth Equal To Slab/Panel Thickness Running At Center Of Load Bearing Wall/ Beam/ Supports And On Other Support As Well To Achieve Diaphragm Action As Per Is 1893:2000. The Peripheral Bond Beam Shall Have Minimum 2 Bars Of 12 Mm Dia As Longitudinal Bars Which Shall Be Held Down By Hook Made In 12 Mm Dia Vertical Bars Coming Out From Structural Beam. However Concrete In Groove And Bond Beam Shall Not Be Paid Separately But Shall Be Measured With Aac Reinforced Slab. Precast Or Lintel And Chhajja Shall Be Jointed With Cm 1:6 Or 2 To 3 Mm Thick Polymer Modified Cement Mortar As Per Astmc 1660-09 To Aac Block Masonry. Structural Steel If Used For Providing Support To The Lintels (Such As Cleat Of Angle Iron, C-Section Anchored/Hold Fasted To Column) At Column End Towards (Where Door / Window Opening Is Adjacent To The Column) Shall Not Be Paid Separately. Rate Includes All Handling, Transportation, Hire Charges Of Machineries Scaffolding And Anti- Corrosive Protective Coating On Reinforcement Inside Aac Slab / Lintel/Chhajja Etc. Complete Up To Floor Two Levels. All Reinforcement Of Peripheral Bond Beam, Grooves And Inside Aac Slab, Lintel, And Chhajja Shall Be Paid @ Sor Rate (Including Tender Percentage) Separately. Quantity Of Reinforcement Steel Provided Inside Aac Slab, Lintel And Chhajja Shall Be Ascertained On The Basis Of Manufacturer’S Certificate And Also By Random Destructive Testing Done By Engineer-In-Charge Or His Representative For Which Cost Of Samples And Testing Charges Shall Be Borne By The Contractor. Deflection & Ultimate Load Test For Aac Reinforced Roof Slab And Lintel Shall Be As Per Annex. B Of Is: 6073 -2006 And Criteria For Conformity And Sampling Shall Be As Per Clause-13 Of Is: 6073 -2006. 39 7.1 7.1.1 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4147.0 40 7.2 7.2.1 Cement Mortar 1:6 (1Cement: 6 Sand). Cum 4351.0 41 7.4 7.4.1 Square Or Rectangular Pillars Cum 213.0 7.4.2 Circular Pillars. Cum 894.0 42 7.6 7.6.1 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4603.0 7.6.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4342.0 43 7.7 7.7.1 Masonry Work (First Sort) In Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4803.0 7.7.2 Masonry Work (Second Sort) , In Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4541.0 44 7.9 7.9.1 Square Or Rectangular Pillars Cum 235.0 7.9.2 Circular Pillars. Cum 1003.0 7.9.3 Extra For Coursed Rubble Masonry With Hard Stone (First Or Second Sort) Curved On Plan For A Mean Radius Not Exceeding 6 M. Cum 384.0 45 7.26 7.26.1 Red Sand Stone: With Common Burnt Clay Bricks Of 25 Kg/Cm2 Compressive Strength. Sqm 1196.0 7.26.2 White Sand Stone With Common Burnt Clay Bricks Of 25 Kg/Cm2 Compressive Strength. Sqm 1196.0 46 7.27 7.27.1 Red Sand Stone Sqm 744.0 7.27.2 White Sand Stone Sqm 744.0 47 7.32 Note: - The Quantity Will Be Calculated By Multiplying The Depth Measured From Sub - Soil Water Level Up To The Centre Of Gravity Of Stone Work Under Sub - Water With The Quantity Of Stone Work In Cum Executed Under The Sub - Soil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1 M. 0.05 M Or More Shall Be Taken As 0.1 M And Less Than 0.05 M Ignored. 48 8.2 (A) Structural Analysis And Design And Preparation Of Shop Drawings For The Specified Design Loads Conforming To Is 875 Part Iii (The System Must Passed The Proof Test At 1.5 Times Design Wind Pressure Without Any Failure), Including Functional Design Of The Aluminum Sections For Fixing Glazing Panels Of Various Thicknesses, Aluminium Cleats, Sleeves And Splice Plates Etc. Gaskets, Screws, Toggles, Nuts, Bolts, Clamps Etc., Structural And Weather Silicone Sealants, Flashings, Fire Stop (Barrier)-Cum-Smoke Seals, Microwave Cured Epdm Gaskets For Water Tightness, Pressure Equalisation And Drainage And Protection Against Fire Hazard Including: (B) Fabricating And Supplying Serrated M.S. Hot Dip Galvanised / Aluminium Alloy Of 6005 T5 Brackets Of Required Sizes, Sections And Profiles Etc. To Accommodate 3 Dimentional Movement For Achieving Perfect Verticality And Fixing Structural Glazing System Rigidly To The Rcc/ Masonry/Structural Steel Framework Of Building Structure Using Stainless Steel Anchor Fasteners/ Bolts, Nylon Seperator To Prevent Bimetallic Contacts With Nuts And Washers Etc. Of Stainless Steel Grade 316, Of The Required Capacity And In Required Numbers. (C) Providing And Filling, Two Part Pump Filled, Structural Silicone Sealant And One Part Weather Silicone Sealant Compatible With The Structural Silicone Sealant Of Required Bite Size In A Clean And Controlled Factory / Work Shop Environment, Including Double Sided Spacer Tape, Setting Blocks And Backer Rod, All Of Approved Grade, Brand And Manufacture, As Per The Approved Sealant Design, Within And All Around The Perimeter For Holding Glass. (D) Providing And Fixing In Position Flashings Of Solid Aluminium Sheet 1 Mm Thick And Of Sizes, Shapes And Profiles, As Required As Per The Site Conditions, To Seal The Gap Between The Building Structure And All Its Interfaces With Curtain Glazing To Make It Watertight. (E) Making Provision For Drainage Of Moisture/ Water That Enters The Curtain Glazing System To Make It Watertight, By Incorporating Principles Of Pressure Equalization, Providing Suitable Gutter Profiles At Bottom (If Required), Making Necessary Holes Of Required Sizes And Of Required Numbers Etc. Complete. This Item Includes Cost Of All Inputs Of Designing, Labour For Fabricating And Installation Of Aluminium Grid, Installation Of Glazed Units, Tandp, Scaffolding And Other Incidental Charges Including Wastages Etc., Enabling Temporary Structures And Services, Cranes Or Cradles Etc. As Described Above And As Specified. The Item Includes The Cost Of Getting All The Structural And Functional Design Including Shop Drawings Checked By A Structural Designer, Dully Approved By Engineer-In-Charge. The Item Also Includes The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individual Components For Testing In An Approved Laboratory, Field Tests On The Assembled Working Structural Glazing As Specified, Cleaning And Protection Till The Handing Over Of The Building For Occupation. In The End, The Contractor Shall Provide A Water Tight Structural Glazing Having All The Performance Characteristics Etc. All Complete As Required, As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineerin- Charge. Note: - 1. The Cost Of Providing Extruded Aluminium Frames, Shadow Boxes, Extruded Aluminium Section Capping For Fixing In The Grooves Of The Curtain Glazing And Vermin Proof Stainless Steel Wire Mesh Shall Be Paid For Separately Under Relevant Items Under This Sub- Head. However, For The Purpose Of Payment, Only The Actual Area Of Structural Glazing (Including Width Of Grooves) On The External Face Shall Be Measured In Sqm. Upto Two Decimal Places.Note: 2. The Following Performance Test Are To Be Conducted On Structural Glazing System If Area Of Structural Glazing Exceeds 2500 Sqm From The Certified Laboratories Accreditated By Nabl (National Accreditation Board For Testing And Calibration Laboratories), Department Of Science And Technologies, India. Cost Of Testing Is Inclusive In The Rates. Performance Testing Of Structural Glazing System Tests To Be Conducted In The Nabl Certified Laboratories(1) Performance Laboratory Test For Air Leakage Test (-50Pa To – 300Pa) And (+50Pa To +300Pa) As Per Astm E-283-04 Testing Method For A Range Of Testing Limit 1 To 200 Mvhr”(2) Static Water Penetration Test. (50Pa To 1500Pa) As Per Astme- 331-09 Testing Method For A Range Upto 2000 Ml.”(3) Dynamic Water Penetration (50Pa To 1500Pa) As Per Aama 501.01-05 Testing Method For A Range Upto 2000 Ml”(4) Structural Performance Deflection And Deformation By Static Air Pressure Test (1.5 Times Design Wind Pressure Without Any Failure) As Per Astme-330-10 Testing Method For A Range Upto 50 Mm”(5) Seismic Movement Test (Upto 30 Mm) As Per Aama 501.4-09 Testing Method For Qualitative Test” Tests To Be Conducted On Site (6) Onsite Test For Water Leakage For A Pressure Range 50 Kpa To 240 Kpa (35Psi) Upto 2000Ml” 49 8.3 (I) Coloured Tinted Float Glass 6Mm Thick Substrate With Reflective Soft Coating On Face # 2, + 12Mm Airgap + 6Mm Heat Strengthened Clear Glass Of Approved Make Having Properties As Visible Light Transmittance (Vlt) Of 25 To 35 %, Light Reflection Internal 10 To 15%, Light Reflection External 10 To 20 %, Shading Coefficient (0.25- 0.28) And U Value Of 3.0 To 3.3 W/M2 Degree K Etc. The Properties Of Performance Glass Shall Be Decided By Technical Sanctioning Authority As Per The Site Requirement. 50 8.5 The Insulation Layer Shall Have Facing (Factory Bonded On Surface # 1 Of The Fibre Glass Insulation Layer), Of Black Non- Woven Fibre Glass Tissue Of Nominal Thickness 0.5 Mm And Nominal Mass Not Less Than 60 Gm/Sqm, Made Of Randomly Oriented Glass Fibres Distributed In A Binder By A Wet-Lay Process Including Fixing 1.5 Mm Thick Solid Aluminum Sheet Backing Using, 6 Mm Thick Cement Board Including Ss Rivets, Nuts, Bolts,Washers Etc Complete. 51 8.6 %, Light Reflection Internal 10 To 15%, Light Reflection External 10 To 20 %, Shading Coefficient (0.25- 0.28) And U Value Of 3.0 To 3.3 W/M2 Degree K Etc. The Properties Of Performance Glass Shall Be Decided By Technical Sanctioning Authority As Per The Site Requirement. 52 8.7 A) Structural Analysis And Design And Preparation Of Shop Drawings For Pressure Equalisation Or Rain Screen Principle As Required, Proper Drainage Of Water To Make It Watertight Including Checking Of All The Structural And Functional Design. B) Providing, Fabricating And Supplying And Fixing Panels Of Aluminium Composite Panel Cladding In Pan Shape In Metalic Colour Of Approved Shades.The Aluminium Composite Panel Cladding Sheet Shall Be Coil Coated, With Kynar 500 Based Pvdf / Fluoropolymer Resin Coating Of Approved Colour And Shade On Face # 1 And Polymer (Service) Coating On Face # 2 As Specified Using Stainless Steel Screws, Nuts, Bolts, Washers, Cleats, Weather Silicone Sealant, Backer Rods Etc. C) The Fastening Brackets Of Aluminium Alloy 6005 T5 / Ms With Hot Dip Galvanised With Serrations And Serrated Washers To Arrest The Wind Load Movement, Fasteners, Ss 316 Pins And Anchor Bolts Of Approved Make In Ss 316, Nylon Separators To Prevent Bi-Metallic Contacts All Complete Required To Perform As Per Specification And Drawing The Item Includes Cost Of All Material And Labour Component, The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individual Components For Testing In An Approved Laboratory, Field Tests On The Assembled Working Curtain Wall With Aluminium Composite Panel Cladding, Cleaning And Protection Of The Curtain Wall With Aluminium Composite Panel Cladding Till The Handing Over Of The Building For Occupation. Base Frame Work For Acp Cladding Is Payable Under The Relevant Aluminium Items. The Contractor Shall Provide Curtain Wall With Aluminium Composite Panel Cladding, Having All The Performance Characteristics All Complete, As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineer- In-Charge. However, For The Purpose Of Payment, Only The Actual Area On The External Face Of The Curtain Wall With Aluminum Composite Panel Cladding (Including Width Of Groove) Shall Be Measured In Sqm. Upto Two Decimal Places. 4 Mm Thick Alumminium Composite Pannel Material Consisting Of 3 Mm Thick Fr Grade Mineral Core Sandwiched Between Two Alumminium Sheets (Each 0.5Mm Thick) Sqm 3800.0 4 Mm Thick Alumminium Composite Pannel Material Consisting Of 3.5 Mm Thick Fr Grade Mineral Core Sandwiched Between Two Alumminium Sheets (Each 0.25Mm Thick) Sqm 3556.0 3 Mm Thick Alumminium Composite Pannel Material Consisting Of 2.5 Mm Thick Fr Grade Mineral Core Sandwiched Between Two Alumminium Sheets (Each 0.25Mm Thick) Sqm 3312.0 53 9.1 9.1.1 Second Class Teak Wood Cum 90618.0 9.1.2 Sal Wood Cum 71309.0 9.1.3 Kiln Head Wood Seasoned And Chemically Treated Hard Wood (Haldu, Kail, Bija Wood.) Cum 72744.0 9.1.4 Factory Made Kiln Seasoned, Chemically Treated, Finger Jointed At Spacing Not Closer Than 50 Cm, 2Nd Class Hard Wood 9.1.4.1 Frame Of Size 100Mmx60Mm Single Or Double Rebate Meter 389.0 9.1.4.2 Frame Of Size 120Mmx60Mm Double Rebate. Meter 457.0 54 9.3 9.3.1 Sal Wood Cum 76229.0 9.3.2 Kiln Seasoned And Chemically Treated Hardwood Haldu, Kail, Bija Wood. Cum 77538.0 9.3.3 Factory Made Kiln Seasoned, Chemically Treated, Finger Jointed At Spacing Not Closer Than 50 Cm, 2Nd Class Hard Wood. Cum 64833.0 55 9.5 9.5.1 Second Class Teak Wood 9.5.1.1 35 Mm Thick Shutters Sqm 2776.0 9.5.1.2 30 Mm Thick Shutters Sqm 2448.0 9.5.2 Kiln Seasoned And Chemically Treated Hardwood Haldu, Kail, Bija Wood. 9.5.2.1 35 Mm Thick Shutters Sqm 2205.0 9.5.2.2 30 Mm Thick Shutters Sqm 1956.0 9.5.3 Kiln Seasoned Selected Planks Of Sheesham Wood. 9.5.3.1 35 Mm Thick Shutters Sqm 2060.0 9.5.3.2 30 Mm Thick Shutters Sqm 1816.0 9.5.4 Factory Made Kiln Seasoned Chemically Treated And Finger Jointed At Spacing Not Closer Than 50Cm, 2Nd Class Hard Wood Shutters 9.5.4.1 35 Mm Thick Sqm 1089.0 9.5.4.2 30 Mm Thick Sqm 969.0 56 9.6 9.6.1 Second Class Teak Wood Sqm 2215.0 9.6.2 Kiln Seasoned And Chemically Treated Hardwood Haldu, Kail, Bija Wood. Sqm 1763.0 9.6.3 15Mm Thick Factory Made Kiln Seasoned, Chemically Treated And Finger Jointed At Spacing Not Closer Than 50Cm, 2Nd Class Hard Wood. Sqm 971.0 9.6.4 Ply Wood 5 Ply, 9 Mm Thick : 9.6.4.1 Decorative Plywood Both Side Decorative Veneer (Type - I) Conforming To Is 1328 Bwr Type. Sqm 1439.0 9.6.4.2 Decorative Plywood One Side Decorative Veneer And Commercial Veneer On Other Face (Type 1) Conforming To Is 1328 Bwr Type Sqm 1369.0 9.6.5 Ply Wood 7 Ply, 9 Mm Thick : 9.6.5.1 Decorative Plywood Both Side Decorative Veneer (Type - I) Conforming To Is 1328 Bwr Type. Sqm 1861.0 9.6.5.2 Decorative Plywood One Side Decorative Veneer And Commercial Veneer On Other Face (Type 1) Conforming To Is 1328 Bwr Type Sqm 1650.0 9.6.6 Particle Board 12 Mm Thick 9.6.6.1 Plain Particle Board Flat Pressed, 3 Layer Or Graded Wood Particle Board Medium Density Grade I, Is: 3087 Marked. Sqm 791.0 9.6.6.2 Veneered Flat Pressed Three Layer Or Graded Wood Particle Board With Commercial Veneering On Both Sides Conforming To Is: 3097, Grade I. Sqm 1087.0 9.6.6.3 Pre-Laminated Particle Board With Sqm 1333.0 Decorative Lamination On One Side And Balancing Lamination On Other Side, Grade I, Type Ii Is: 12823 Marked. 9.6.6.4 Pre-Laminated Particle Board With Decorative Lamination On Both Sides, Grade I, Type Ii, Is: 12823 Marked. Sqm 1390.0 9.6.6.5 Coir Veneer Board (Conforming To Is 14842) 12 Mm Thick Sqm 1298.0 9.6.7 Float Glass Panes 9.6.7.1 4 Mm Thick Glass Pane (Weight Not Less Than 10 Kg/Sqm) Sqm 973.0 9.6.7.2 5 Mm Thick Glass Pane (Weight Not Less Than 12.5 Kg/Sqm) Sqm 1046.0 9.6.8 Fly Proof Stainless Steel Grade 304 Wire Gauge With 0.5 Mm Dia. Wire And 1.4 Mm Wide Aperture With Matching Wood Beading Sqm 1532.0 9.6.8.1 4Mm To 5Mm Thick Integral Pvc Form Sheet With Celluka Finish Surface On Both Side With Density Not Less Than 600 Kg/Cum Sqm 580.0 9.6.8.2 4Mm To 5Mm Thick Laminated Pvc Form Sheet With Density Not Less Than 600 Kg/Cum, Laminated On Both Sides By 0.12 Mm Thick Laminated Sheet With Density Not Less Than 1400 Kg/Cum Sqm 754.0 57 9.7 9.7.1 12Mm Thick Plain Grade - 1, Medium Density Flat Pressed Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpt - I Is : 3087 Marked Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 : Sqm 2717.0 9.7.2 12 Mm Thick Pre-Laminated Particle Board (Decorative Lamination On Both Sides) Grade - 1, Medium Density Flat Pressed, Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpt - I, Conforming To Is : 3087 Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 And Pre- Lamination Conforming To Is : 12823 Grade 1, Type - Ii Marked: Sqm 2868.0 9.7.3 12 Mm Thick One Side Pre-Laminated Particle Board (Decorative Lamination On One Side And Other Sides Balancing Lamination) Grade - 1 Medium Density Flat Pressed, Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpt-1 Conforming To Is : 3087 Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 And Prelamination Conforming To Is : 12823 Grade -1, Type Ii Marked: Sqm 2775.0 58 9.8 9.8.1 Second Class Teak Wood 9.8.1.1 35 Mm Thick Sqm 3408.0 9.8.1.2 30 Mm Thick Sqm 3033.0 9.8.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood 9.8.2.1 35 Mm Thick Sqm 2758.0 9.8.2.2 30 Mm Thick Sqm 2474.0 9.8.3 Kiln Seasoned Selected Planks Of Sheesham Wood. 9.8.3.1 35 Mm Thick Sqm 2594.0 9.8.3.2 30 Mm Thick Sqm 2331.0 9.8.4 Factory Made Kiln Seasoned Chemically Treated And Finger Jointed At Spacing Not Closer Than 50Cm, 2Nd Class Hard Wood Shutters 9. 8.4.1 30 Mm Thick Shutters Sqm 1469.0 9. 8.4.2 35 Mm Thick Shutters Sqm 1589.0 59 9.1 9.10.1 5 Mm Thick Instead Of 4 Mm Thick. Sqm 73.0 9.10.2 10 To 12 Mm Float Glass Sqm 132.0 9.10.3 5.5 Mm Safety Glass Sqm 400.0 9.10.4 10-12Mm Safety Glass Sqm 960.0 60 9.13 Deduct For Not Providing Hinges In Doors, Windows Or Clerestory Window Shutters With : 9.14.1 Stainless Steel Butt Hinges With Stainless Steel Screws For 2Nd Class Teak Wood And Other Class Of Wood Shutters. Sqm 170.0 9.14.2 Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size For 2Nd Class Teak Wood And Other Class Of Wood Shutters. Sqm 53.0 61 9.15 9.15.1 Panelled Or Panelled And Glazed Shutters : 9.15.1.1 Using Isi Marked Anodised Aluminium Butt Hinges With Necessary Screws. Sqm 2736.0 9.15.1.2 Using Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2753.0 9.15.2 Glazed Shutters : 9.15.2.1 Second Class Teak Wood Including Isi Marked Anodised Aluminium Butt Hinges With Necessary Screws. Sqm 2815.0 9.15.2. 2Nd Class Teak Wood Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2759.0 62 9.16 9.16.1 12 Mm Thick Sqm 555.0 9.16.2 18 Mm Thick Sqm 654.0 63 9.17 9.17.1 18 Mm Thick Sqm 1270.0 9.17.2 25 Mm Thick Sqm 1383.0 64 9.18 9.18.1 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws. Sqm 2600.0 9.18.2 30 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws. Sqm 2370.0 9.18.3 25 Mm Thick (For Cupboard) Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges Is: 3818 Marked With Necessary Screws. Sqm 2119.0 65 9.19 9.19.1 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws. Sqm 1622.0 9.19.2 30 Mm Thick Including Isi Marked Sqm 1564.0 Stainless Steel Butt Hinges With Necessary Screws. 9.19.3 25Mm Thick (For Cupboard) Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 1533.0 66 9.22 9.22.1 Rectangular Or Square. Sqm 157.0 9.22.2 Circular. Sqm 244.0 67 9.25 9.25.1 35 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.25.1.1 Second Class Teak Wood. Sqm 3174.0 9.25.1.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2599.0 9.25.1.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2452.0 9.25.2 35 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size. 9.25.2.1 Second Class Teak Wood. Sqm 3291.0 9.25.2.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2716.0 9.25.2.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2569.0 9.25.3 30 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.25.3.1 Second Class Teak Wood. Sqm 2797.0 9.25.3.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2306.0 9.25.3.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2179.0 9.25.4 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size. 9.25.4.1 Second Class Teak Wood. Sqm 2914.0 9.25.4.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2423.0 9.25.4.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2296.0 68 9.26 9.26.1 35 Mm Thick Shutters Sqm 2427.0 9.26.2 30 Mm Thick Shutters Sqm 2102.0 69 9.28 9.28.1 25 Mm Long Each 16.0 9.28.2 32 Mm Long Each 18.0 9.28.3 40 Mm Long Each 21.0 9.28.4 50 Mm Long Each 25.0 9.28.5 60 Mm Long Each 28.0 70 9.29 9.29.1 40 Mm Thick. Sqm 5407.0 9.29.2 25 Mm Thick. Sqm 3469.0 9.29.3 20 Mm Thick Sqm 2802.0 9.29.4 12 Mm Thick Sqm 1768.0 71 9.3 9.30.1 12 Mm Thick Sqm 1174.0 9.30.2 18 Mm Thick Sqm 1410.0 9.30.3 25 Mm Thick Sqm 1525.0 72 .9.32 73 9.34 9.34.1 18 Mm Thick Sqm 1626.0 9.34.2 25 Mm Thick Sqm 1741.0 74 9.35 9.35.1 2Nd Class Teak Wood 9.35.1.1 50X12 Mm Metre 102.0 9.35.1.2 50 X 20 Mm Metre 147.0 9.35.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. 9.35.2.1 50X12 Mm Metre 85.0 9.35.2.2 50X20 Mm Metre 119.0 75 9.39 9.39.1 Non Decorative Veneer On Both Sides. Metre 34.0 9.39.2 Particle Board With Decorative Veneering On Both Sides. Metre 102.0 76 9.41 9.41.1 12 Mm Dia. Metre 289.0 9.41.2 20 Mm Dia. Metre 377.0 9.41.3 25 Mm Dia. Metre 382.0 77 9.42 9.42.1 20 Mm Dia (Heavy Type) Metre 127.0 9.42.2 25 Mm Dia (Heavy Type) Metre 141.0 78 9.43 9.43.1 Fixed To Steel Windows By Welding. Kg 91.0 9.43.2 Fixed To Openings /Wooden Frames With Rawl Plugs Screws Etc. Kg 100.0 79 9.46 9.46.1 With 2Nd Class Teak Wood Beading 62X19 Mm. Sqm 1000.0 9.46.2 With 12 Mm Mild Steel U Beading. Sqm 681.0 80 9.5 9.50.1 125X65X2.12 Mm Each 30.0 9.50.2 100X58X1.90 Mm Each 23.0 9.50.3 75X47X1.70 Mm Each 18.0 9.50.4 50X37X1.50 Mm Each 10.0 81 9.51 9.51.1 125X90X4.00 Mm Each 53.0 9.51.2 100X75X3.50 Mm Each 35.0 9.51.3 75X60X3.10 Mm Each 21.0 9.51.4 50X40X2.50 Mm Each 13.0 82 9.52 9.52.1 125X65X2.12 Mm Each 32.0 9.52.2 100X58X1.90 Mm Each 23.0 9.52.3 75X47X1.70 Mm Each 17.0 9.52.4 50X37X1.50 Mm Each 10.0 83 9.53 9.53.1 150X125X27X2.80 Mm Each 58.0 9.53.2 125X125X27X2.80 Mm Each 55.0 9.53.3 100X125X27X2.80 Mm Each 46.0 9.53.4 75X100X20X2.24 Mm Each 39.0 84 9.54 9.54.1 150 Mm Each 169.0 9.54.2 125 Mm Each 163.0 9.54.3 100 Mm Each 131.0 85 9.55 9.55.1 150 Mm Each 174.0 9.55.2 125 Mm Each 163.0 9.55.3 100 Mm Each 137.0 86 9.56 9.56.1 Overall Width 35 Mm. Metre 133.0 9.56.2 Overall Width 50 Mm. Metre 138.0 9.56.3 Overall Width 65 Mm. Metre 141.0 87 9.57 9.57.1 300X16 Mm Each 170.0 9.57.2 250X16 Mm Each 157.0 88 9.58 9.58.1 250X10 Mm Each 68.0 9.58.2 200X10 Mm Each 60.0 9.58.3 150X10 Mm Each 42.0 9.58.4 100X10 Mm Each 35.0 89 0.6 9.60.1 300X20X6 Mm Each 72.0 9.60.2 250X20X6 Mm Each 67.0 90 9.61 9.61.1 125 Mm Each 27.0 9.61.2 100 Mm Each 25.0 9.61.3 75 Mm Each 24.0 91 9.62 9.62.1 150 Mm Each 23.0 9.62.2 115 Mm Each 20.0 9.62.3 90 Mm Each 17.0 92 9.63 9.63.1 300 Mm Weighing Not Less Than 200 Gms. Each 40.0 9.63.2 250 Mm Weighing Not Less Than 150 Gms. Each 34.0 9.63.3 200 Mm Weighing Not Less Than 120 Gms. Each 28.0 93 9.65 9.65.1 300X16 Mm Each 389.0 9.65.2 250X16 Mm Each 326.0 94 9.66 9.66.1 250X10 Mm Each 148.0 9.66.2 200X10 Mm Each 93.0 9.66.3 150X10 Mm Each 71.0 9.66.4 100X10 Mm Each 50.0 95 9.68 9.68.1 300X20X6 Mm Each 211.0 9.68.2 250X20X6 Mm Each 173.0 96 9.69 9.69.1 125 Mm Each 60.0 9.69.2 100 Mm Each 54.0 9.69.3 75 Mm Each 48.0 97 9.7 9.70.1 150 Mm Each 37.0 9.70.2 115 Mm Each 33.0 9.70.3 90 Mm Each 26.0 98 9.71 9.71.1 300 Mm Weighing Not Less Than 200 Gms. Each 79.0 9.71.2 250 Mm Weighing Not Less Than 150 Gms. Each 61.0 9.71.3 200 Mm Weighing Not Less Than 120 Gms. Each 49.0 99 9.73 9.73.1 125X64X1.90 Mm Each 67.0 9.73.2 100X58X1.90 Mm Each 59.0 9.73.3 75X47X1.80 Mm Each 39.0 9.73.4 50X37X1.50 Mm Each 25.0 100 9.74 9.74.1 125X64X2.50 Mm Each 76.0 9.74.2 100X60X2.50 Mm Each 60.0 9.74.3 75X50X2.50 Mm Each 46.0 101 9.77 9.77.1 125X85X5.5 Mm (Heavy Type) Each 456.0 9.77.2 125X70X4 Mm (Ordinary Type) Each 148.0 9.77.3 100X85X5.5 Mm (Heavy Type) Each 387.0 9.77.4 100X70X4 Mm (Ordinary Type) Each 117.0 9.77.5 75X65X4 Mm (Heavy Type) Each 145.0 9.77.6 75X40X2.5 Mm (Ordinary Type) Each 74.0 9.77.7 50X40X2.5 Mm (Ordinary Type) Each 32.0 102 9.78 9.78.1 150X125X27X5 Mm Each 385.0 9.78.2 125X125X27X5 Mm Each 345.0 9.78.3 100X125X27X5 Mm Each 304.0 9.78.4 75X100X20X3.2 Mm Each 239.0 103 9.79 9.79.1 400X10 Mm Each 400.0 9.79.2 250X10 Mm Each 329.0 9.79.3 200X10 Mm Each 261.0 9.79.4 150X10 Mm Each 221.0 9.79.5 100X10 Mm Each 142.0 104 9.8 9.80.1 300X16X5 Mm Each 237.0 9.80.2 250X16X5 Mm Each 225.0 105 9.81 9.81.1 125 Mm Each 205.0 9.81.2 100 Mm Each 181.0 9.81.3 75 Mm Each 141.0 106 9.82 9.82.1 300X16Mm Each 407.0 9.82.2 250X16Mm Each 374.0 107 9.87 9.87.1 40 Mm Each 144.0 9.87.2 50 Mm Each 150.0 9.87.3 65 Mm Each 162.0 9.87.4 75 Mm Each 185.0 108 9.39 9.91.1 300 Mm Weighing Not Less Than 330 Gms Each 184.0 9.91.2 250 Mm Weighing Not Less Than 280 Gms Each 147.0 9.91.3 200 Mm Weighing Not Less Than 240 Gms Each 136.0 109 9.92 9.92.1 150 Mm Each 115.0 9.92.2 115 Mm Each 94.0 9.92.3 90 Mm Each 80.0 110 9.99 9.99.1 Size 40 Mm Each 144.0 9.99.2 Size 50 Mm Each 156.0 9.99.3 Size 65 Mm Each 167.0 9.99.4 Size 75 Mm Each 196.0 111 9.101 9.101.1 300X16Mm Each 268.0 9.101.2 250X16Mm Each 245.0 112 9.102 9.102.1 400X10Mm Each 260.0 9.102.2 300X10Mm Each 198.0 9.102.3 250X10Mm Each 164.0 9.102.4 200X10 Mm Each 113.0 9.102.5 150X10 Mm Each 91.0 9.102.6 100X10 Mm Each 73.0 113 9.1 9.103.1 300X16X5Mm Each 255.0 9.103.2 250X16X5Mm Each 243.0 114 9.104 115 9.105 9.105.1 125 Mm Each 241.0 9.105.2 100 Mm Each 206.0 9.105.3 75 Mm Each 182.0 116 9.106 117 9.107 9.107.1 300 Mm Weighing Not Less Than 330 Gms Each 207.0 9.107.2 250 Mm Weighing Not Less Than 280 Gms Each 178.0 9.107.3 200 Mm Weighing Not Less Than 240 Gms Each 149.0 118 9.108 Note:- Aluminum Hinges Shall Not Be Used In Wooden Shutters. 9.108.1 125X75X4 Mm Each 115.0 9.108.2 125X63X4 Mm Each 108.0 9.108.3 100X75X4 Mm Each 95.0 9.108.4 100X63X4 Mm Each 93.0 9.108.5 100X63X3.2 Mm Each 90.0 9.108.6 75X63X4 Mm Each 77.0 9.108.7 75X63X3.2 Mm Each 75.0 9.108.8 75X45X3.2 Mm Each 67.0 119 9.109 9.109.1 300X16 Mm Each 241.0 9.109.2 250X16 Mm Each 195.0 120 9.11 9.110.1 400X10Mm Each 123.0 9.110.2 300X10 Mm Each 114.0 9.110.3 250X10 Mm Each 102.0 9.110.4 200X10 Mm Each 82.0 9.110.5 150X10 Mm Each 69.0 9.110.6 100X10 Mm Each 55.0 121 9.111 122 9.112 123 9.113 9.113.1 125 Mm Each 75.0 9.113.2 100 Mm Each 55.0 9.113.3 75 Mm Each 46.0 124 9.114 9.114.1 Single Rubber Stopper Each 35.0 9.114.2 Twin Rubber Stopper Each 86.0 125 9.115 126 9.116 127 9.117 128 9.118 9.118.1 125X34X24 Mm Weighing Not Less Than 23 Gms. Each 44.0 9.118.2 150X34X24 Mm Weighing Not Less Than 26 Gms. Each 48.0 129 9.119 9.119.1 75X60X10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms. Each 62.0 9.119.2 100X75X10 Mm Fitted With 5.5 Mm Dia Ms Bright Bar Rod Weighing Not Less Than 53 Gms. Each 82.0 130 9.12 9.120.1 152X42X18 Mm Weighing Not Less Than 60 Gms. Each 87.0 9.120.2 202X42X18 Mm Weighing Not Less Than 78 Gms. Each 106.0 131 9.121 132 9.122 133 9.123 9.123.1 35 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.123.1.1 Second Class Teak Wood. Sqm 3583.0 9.123.1.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 3008.0 9.123.1.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2862.0 9.123.2 35 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size. 9.123.2.1 Second Class Teak Wood. Sqm 3700.0 9.123.2.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 3125.0 9.123.2.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2979.0 9.123.3 30 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.123.3.1 Second Class Teak Wood. Sqm 3206.0 9.123.3.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2715.0 9.123.3.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2589.0 9.123.4 30 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.123.4.1 Second Class Teak Wood. Sqm 3323.0 9.123.4.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2832.0 9.123.4.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2706.0 134 9.124 9.124.1 With 2Nd Class Teak Wood Beading 62X19 Mm. Sqm 1689.0 9.124.2 With 12 Mm Mild Steel U Beading. Sqm 1370.0 135 9.126 136 9.127 137 9.128 138 9.129 9.129.1 Triple Strip Vertical Type. Each 28.0 9.129.2 Double Strip (Horizontal Type). Each 23.0 139 9.131 9.131.1 300Mm Long Each Set 209.0 9.131.2 450Mm Long Each Set 256.0 9.131.3 500Mm Long Each Set 302.0 140 9.132 141 9.133 9.133.1 Marine Plywood Conforming To Is: 710 Sqm 1591.0 9.133.2 Fire Retardant Plywood Conforming To Is: 5509 Sqm 1660.0 142 9.134 9.134.1 1.5 Mm Thick. Sqm 851.0 9.134.2 1.0 Mm Thick. Sqm 691.0 143 9.135 144 9.136 9.136.1 With Decorative Veneering On One Side And Commercial Veneering On Other Side. Sqm 1433.0 9.136.2 With Non Decorative Veneering On Both Sides. Sqm 1322.0 145 9.137 146 9.138 9.138.1 12 Mm Thick. Sqm 919.0 9.138.2 18 Mm Thick. Sqm 1161.0 9.138.3 25 Mm Thick. Sqm 1230.0 147 9.139 148 9.14 9.140.1 18 Mm Thick Sqm 1493.0 9.140.2 25 Mm Thick Sqm 2017.0 149 9.143 25Mm To 40Mm Thick: Pre-Laminated With Decorative Lamination On Both Side Exterior Grade - I Mdf Board 12 Mm Thick Confirming To Is:14587 150 9.145 9.145.1 Board 12 Mm Thick Sqm 811.0 9.145.2 Board 18 Mm Thick Sqm 943.0 151 9.146 9.146.1 18 Mm Thick Sqm 1055.0 9.146.2 25 Mm Thick Sqm 1420.0 152 9.158 9.158.1 Extruded Section Profile Size 48X40 Mm. Metre 203.0 9.158.2 Extruded Section Profile Size 42X50 Mm. Metre 208.0 153 9.159 154 9.161 155 9.165 156 9.166 9.166.1 Plain Pvc Door Shutters. Sqm 2026.0 9.166.2 Pre Laminated Pvc Door Shutters. Sqm 2490.0 157 9.167 158 9.168 Non Decorative Finish. Sqm 2026.0 Decorative Finish (Both Side Wood Grained Finish). Sqm 2432.0 159 9.175 160 9.176 9.176.1 Non Decorative Finish (Matt Finish). Sqm 2037.0 9.176.2 Decorative Finish (Wood Grained Finish). Sqm 2142.0 161 9.177 162 9.182 163 9.183 164 9.184 165 9.185 166 9.186 167 9.187 9.187.1 Casement Window (Outward/Inward Opening) With Hinge System. 9.187.1.1 Frame (50 Mm X 50Mm) Metre 422.0 9.187.1.2 Sash (Style And Rail) (62 Mm X 34 Mm) Metre 403.0 9.187.1.3 Mullion (Intermediate Section) (66Mm X 50 Mm) Metre 434.0 9.187.1.4 ‘T Profile (One Vertical Length In Between Two Shutters) (24Mm X 34.5Mm) Metre 99.0 9.187.1.5 Glazing Bead (12Mm X 18Mm) Metre 130.0 9.187.2 Casement Window (With Friction Hinge And Outward Opening) 9.187.2.1 Casement Frame (67Mm X 62Mm) Metre 495.0 9.187.2.2 Casement Window Sash/Mullion (67Mm X75Mm) (Style, Rail And Intermediate Section) Metre 519.0 9.187.2.3 Casement Glazing Bead (35Mm X 18 Mm) Metre 178.0 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67Mm X 52Mm) Metre 9.187.3.2 Sliding Window Sash (60Mm X 44Mm) Metre 529.0 9.187.3.3 Sliding Interlock For Window (One Vertical Length In Each Shutter)(45.5 Mm X 28 Mm) Metre 139.0 9.187.3.4 Sliding Glazing Bead (35 Mm X 18 Mm) Metre 178.0 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67Mm X 52Mm) Metre 539.0 9.187.4.2 Sliding Door Sash (80Mm X 44Mm) Metre 653.0 9.187.4.3 Sliding Interlock For Door (One Vertical Length In Each Shutter) (45.5 Mm X 28 Mm) Metre 139.0 9.187.4.4 Sliding Glazing Bead (35 Mm X 18 Mm) Metre 178.0 168 9.188 9.188.1 200 X 19 X 1.9 Mm Each 321.0 9.188.2 250 X 19 X 1.9 Mm Each 369.0 9.188.3 300 X 19 X 1.9 Mm Each 462.0 9.188.4 350 X 19 X 1.9 Mm Each 526.0 9.188.5 400 X 19 X 1.9 Mm Each 636.0 169 9.189 170 9.191 171 9.192 172 9.193 173 9.194 Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. (Single / Double Glass Panes And Silicon Sealant Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerancein Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 0.75 Sqm.) 9.193.1 Casement Window Single Panel With S.S. Friction Hinges (300 X 19 X 1.9 Mm), Made Of (Small Series) Frame 47 X 50 Mm & Sash 47 X 68 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glass Pane Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 0.75 Sqm.) Sqm 6798.0 9.193.2 Casement Window Double Panels With S.S. Friction Hinges (300 X 19 X 1.9 Mm) Made Of (Small Series) Frame 47 X 50 Mm, Sash 47 X 68 Mm & Mullion 47 X 68 Mm All Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Above 0.75 Sqm Upto 1.50 Sqm). Sqm 6221.0 9.193.3 Casement Window Double Panels With Top Fixed With S.S. Friction Hinges (350 X 19 X 1.9 Mm) Made Of (Small Series) Frame 47 X 50 Mm, Sash 47 X 68 Mm & Mullion 47 X 68 Mm All Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 2.50 Sqm). Sqm 4842.0 9.193.4 Casement Window Single Panel With S.S. Friction Hinges (400 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 60 Mm & Sash 67 X 80 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Sqm 6681.0 9.193.5 Casement Window Duble Panel With S.S. Friction Hinges (400 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 60 Mm & Sash 67 X 80 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.50 Sqm.) Sqm 6942.0 9.193.6 Casement Cum Fixed Panel Window Having Both And Single Casement Panel, Middle Fixed Panels And At Top Completely Fixed Ventilator With S.S. Friction Hinges (350 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 60 Mm & Sash 67 X 80 Mm & Mullion 67 X 80 All Having Wall Thickness Of 2.3 ±0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 3.00 Sqm. Upto 5.00 Sqm.) Sqm 5290.0 174 9.0 194.1 Fixed Window / Ventilator Made Of (Small Series) Frame 47 X 50 Mm & Mullion 47 X 68 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Upto 0.75 Sqm.) Sqm 4860.0 175 9.195 9.195.1 Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Mm & Sash 67 X 110 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Upto 2.00 Sqm). 9.195.2 Casement Door With Top Hung Ventilator With 3D And S.S. Friction Hinges (400 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 64 Mm, Sash 67 X 110 Mm & Mullion 67 X 80 Mm All Having Wall Thickness Of 2.3 ±.0.2 Mm And Single Glazing Bead /Double Glazing Bead Of Appropriate Dimension. (Area Of Door Upto 2.50 Sqm). 176 9.196 Note: - For Upvc Frame, Sash And Mullion Extruede Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. 9.196.1 Two Track Two Panels Sliding Window Made Of Frame 52 X 44 Mm &Sash 32 X 60Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 1.75 Sqm) Sqm 5060.0 9.196.2 Three Track Three Panels Sliding Window With Fly Proof Ss Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of Frame 92 X 44 Mm & Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension (Area Of Window Upto 1.75 Sqm). Sqm 6880.0 9.196.3 Two Track Two Panels Sliding Window Made Of Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension (Area Of Window Above 1.75 Sqm Upto 2.50 Sqm). Sqm 5134.0 9.196.4 Three Track Three Panels Sliding Window With Fly Proof Ss Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of Frame 92 X 44 Mm & Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension (Area Of Glazed & One No. Wire Mesh Panels) Made Of Frame 116 X 45 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead/Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.75 Sqm). Sqm 6371.0 9.196.5 Three Track Three Panels Sliding Window Made Of Frame 116 X 45 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.75 Sqm) Sqm 5913.0 177 9.197 Note: - For Upvc Frame, Sash And Mullion Extruede Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. 9.197.1 Two Track Two Panels Sliding Window Made Of Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 2.50 Sqm Upto 4.00 Sqm). Sqm 4332.0 9.197.2 Two Track Four Panels Sliding Window Made Of Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 4.00 Sqm Upto 8.00 Sqm). Sqm 3532.0 178 9.198 9.198.1 Two Track Two Panels Sliding Door Made Of Frame 67 X 50 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 2.00 Sqm Upto 10.00 Sqm). Sqm 3676.0 9.198.2 Two Track Four Panels Sliding Door Made Of Frame 67 X 50 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 8.00 Sqm Upto10.00 Sqm). Sqm 3810.0 9.198.3 Three Track Three Panels Sliding Door Made Of Frame 116 X 45 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead/ Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 5.00 Sqm) Sqm 4361.0 9.198.4 Three Track Three Panels Sliding Door With Fly Proof S.S Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of Frame 116 X 45 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 2.00 Sqm Upto 5.00 Sqm) Sqm 5617.0 179 9.199 180 9.2 9.200.1 24 To 25 Mm Thick Plain Solid Pvc Flush Door Shutter 9.200.2 28 To 30 Mm Thick Plain Solid Pvc Flush Door Shutter 181 9.201 9.201.1 1Mm Thick Laminated Sheet Sqm 3693.0 9.201.2 0.12 Mm Thick Laminated Sheet Sqm 3461.0 182 9.202 9.202.1 35Mm Thick Including 4 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3339.0 9.202.2 35Mm Thick Including 3 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3171.0 9.202.3 25Mm Thick (For Cupboard) Including 3 Nos. 75Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 3005.0 183 9.203 9.203.1 35Mm Thick Including 4 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary. Sqm 1953.0 9.203.2 30Mm Thick Including 3 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 1772.0 25Mm Thick Including 3 Nos. 100Mm Long, Screws. Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 1532.0 184 9.204 185 9.213 9.213.1 35 Mm Thick Including 4 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 2775.0 9.213.2 30 Mm Thick Including 3 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 2675.0 9.213.3 25Mm Thick (For Cupboard) Including 3 Nos. 75 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2575.0 186 9.214 9.214.1 35 Mm Thick Including 4 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3650.0 9.214.2 30 Mm Thick Including 3 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws.Screws. Sqm 3550.0 9.214.3 25Mm Thick (For Cupboard) Including 3 Nos. 75 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 3450.0 187 9.215 9.215.1 35 Mm Thick Including 4 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3121.0 9.215.2 30 Mm Thick Including 3 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3021.0 9.215.3 25Mm Thick (For Cupboard) Including 3 Nos. 75 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2921.0
Contract Date: Jun 24, 2026 Contract Value : 20.40 Lakh
Government Departments No of Bidders 3
Madhya Pradesh View Result →
48.
Public Administrative Department #11048171 Price Bid
Tender for Construction Of 400 Mtr. Running Track At Suratgarh Stadium
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Contract Date: Ref. Documents Contract Value : 26.05 Lakh
Government Departments No of Bidders 1
TenderDetail
Loading tenders