View Bid Results For Roofing Treatment Tenders

We found 874 Bid Results related to roofing treatment tenders. You can find Contractor details who won roofing treatment tenders along with contract details in Bid awards announcements section.

Filters
Stage
585
152
137
Tender Publishing Platform
18
856
State / UT
31
201
129
101
51
49
46
42
35
25
25
24
23
16
15
10
10
9
9
8
8
7
7
5
4
3
3
3
2
2
1
1
Contract Value
294
68
404
107
Publish Date
2
0
0
0
0
Sector
26
284
161
123
69
38
36
24
23
18
17
15
11
8
8
6
6
5
4
4
4
3
2
2
1
1
1
Ownership
6
414
267
130
55
7
1
Within keyword
Active filters:
Showing 1–18 of 874 tenders matching your filters
1.
Rural Development #11465735 Price Bid
Development Works At Shree Skhetra Jagdamba Devi Sanshtan At Sav. Tq. Dist. Buldana.- 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 2 Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means 3 Excavation for foundation in Hard murum including removing the excavated material upto a distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringand struttingetc. complete. (Lift from1.5 to3.0m.) By Mechanical Means 4 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. 5 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 6 Providing and laying in situ /Ready MixCement concreteM-20of trap / granite /quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchionsetc. including bailing out water,Steel centeringformwork, laying/pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 7 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 8 F.F. 9 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 10 F.F. 11 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landingsas per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 12 F.F. 13 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADAenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 14 F.F. 15 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 16 F.F. 17 Providingandapplyingwaterproofingtreatmentusingacrylicpolymermodifiedcement basedwaterproofingcoatingwithfibreglassmeshmixingattherateofpowdertoliquid (2:1)byweightcovering9to10SquareMetre/Kilogramwithtwocoatusingapproved chemicals for masonry andconcrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. FF 18 Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineer inchargein layers of 15 cmto 20 cm including watering and compaction etc. complete. 19 Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. 20 Providing and laying Cast in situ/Ready Mix Cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 21 Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 22 F.F. 23 Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. FF 24 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm . FF 25 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. FF 26 Providing and fixing 30mm thickPVC FLUSH L DOOR SHUTTER consisting of panel of hollow PVC profile of 20 mm thickness consisting frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mminserted inside the hollow section of stiles rails top ?and bottom railsandtwo19x19mm MStubesinsertedhorizontallyinsidethe hollowprofile section using 4/5 mm sheet using screws hollow profile shall be lipped with 10 mm (5mm x2) thickx20mmwidthonstilesandrailsusingsolventcement.Theinnerpanelshallbe laminatedwith5mm thicktermite proofwaterproof plain/prelam PVCsheet using solvent cementonthebothsidesofthepanelincludingstainlesssteelfixturesandfasteningetc. Complete as per direction of Engineer incharge, manufacturers specification and drawing. FF 27 Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. 28 F.F. 29 Providing andfixing inposition(asper1868/1982)Aluminium sliding windowofthree tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeofbearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre.Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm atweight 0.417Kilogram/Runningmetre.Asperdetaileddrawingsandasdirectedby Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainlesssteeljailwithall required screws and nuts etc, complete. With powder coating without box 30 F.F. 31 Providing and fixing in position powder coated aluminium louvered windows / ventilator of varioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete. FF 32 Providing and fixing foldable mild steel door using fully anodised sections of hollow square pipe 40 X 40 X 4 mm & 80 X 40 X 4 mm, M. S. sheet and grill as per drawing with all accessories etc. complete. (I.S. 105211983). [ Item as per Circular No. 1304 Dt. 24/02/23 33 Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, moulding edges, cleaning complete. a) Marble other than white makrana 34 F.F. 35 Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. 36 F.F. 37 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 38 F.F. 39 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. 40 F.F. 41 Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. 42 F.F. 43 Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete 44 F.F. 45 Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortarincludingfloatfilling jointswithneatcement slurry curing polishing and cleaningetc. complete. 46 F.F. 47 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 48 F.F. 49 Providing and applying plastic emulsion paint of approved quality, colour and shade tonew surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. 50 F.F. 51 Providing and applying two coats ofexterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. 52 F.F. 53 Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and1.5mmthickattop, 40mm diameterand1.5mm thickverticalsupportsspacedat1.5m centertocenterand8mmthicktoughenedglassincludingfabricating,fixtures,errecting, necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete 54 Providing and fabricating structural steel work in rolled sections, fixed with connecting plates oranglecleatsinmainandcrossbeams,hipandjackrafters,purlinsconnectingtotruss members andthe like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil paintingofapproved quality and shade etc. complete. 55 Providingandfixingcorrugatedgalvanisedironsheetsof0.63mmthick(24B.W.G.)for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). 56 Providing and fixing board displaying information, such as Name of work, Tender cost, Name of Contractor, Work completion and liability period etc, having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge 57 Royalty Charges for Metal and Murum 58 Royalty Charges for Sand 59 Fineness Modulus,Silt & Clay Content 60 Compressive Strength 61 Water Absorption. Compressive Strength. Efflorances 62 Gradation 63 Standard Consistancy Fineness, Specific Gravity, Setting Time ( Initial & Final), Compressive Strength, Soundness 64 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 65 Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means 66 Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto1.50m)ByMechanical Means 67 Excavation for foundation in Hard murum including removing the excavated material upto a distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringand struttingetc. complete. (Lift from1.5 to3.0m.) By Mechanical Means 68 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. 69 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 70 Providing and laying in situ /Ready MixCement concreteM-20of trap / granite /quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchionsetc. including bailing out water,Steel centeringformwork, laying/pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 71 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 72 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 73 Providing and laying Cast in situ/Ready Mix Cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landingsas per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(excluding reinforcement and structural steel) with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 74 ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-20oftrap/granite/ quartzite/gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem ifspecialfinishistobeprovidedandcuringcomplete.(Excludingreinforcementand structuralsteel).withfullyautomaticmicroprocessorbasedPLCwithSCADAenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 75 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 76 ProvidingandfixingheavydutyinterlockingconcreteRUBBERMOULDGLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kilogram/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaningetc. complete. (using 100% crushed sand) 77 Providing andlaying Castinsitu/ReadyMixcement concrete M-15oftrap/ granite/quartzite/gneissmetalforcoping to plinthorparapet,mouldedorchamferedasper drawingorasdirectedincludingsteelcentering,plywood/steelformworkcompacting, rougheningthemifspecialfinishistobeprovided,finishingunevenandhoneycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) 78 Providing and fixing board displaying information, such as Name of work, Tender cost, Name of Contractor, Work completion and liability period etc, having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge 79 Royalty Charges for Metal and Murum 80 Royalty Charges for Sand 81 Fineness Modulus,Silt & Clay Content 82 Compressive Strength 83 Standard Consistancy Fineness, Specific Gravity, Setting Time ( Initial & Final), Compressive Strength, Soundness 84 Gradation
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
Jammu And Kashmir View Result →
3.
Power #11454678 AOC
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 2827583; 2827583; Service Provider - Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50 M And Lift Upto 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed. , Supplying And Filling In Plinth With Local Sand/Stone Dust Under Floors Including,Watering, Ramming Consolidating And Dressing Complete. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering-All Work Up To Plinth Level : 1:2:4 (I Cement 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering-All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Brick Work With Common Burnt Clay/Fly Ash F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Kg , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Openings /Wooden Frames With Rawl Plugs Screws Etc. , Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Cold Twisted Bars , Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10x15cm 1:3:6 Mix (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) , Neat Cement Punning , 12 Mm Cement Plaster 1:4 (1 Cement : 4 Coarse Sand) , 12 Mm Cement Plaster 1:6 (1 Cement : 6 Coarse Sand) , 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix 1:6 (1 Cement : 6 Coarse Sand) , Providing And Fixing G.I. Chain Link Fabric Fencing Of Required Width In Mesh Size 50X50 Mm Including Strengthening With 2 Mm Dia Wire Or Nuts, Bolts And Washers As Required Complete As Per The Direction Of Engineer-In-Charge. Made Of G.I. Wire Of Dia. 4 Mm , Providing And Laying Four Courses Water Proofing Treatment With Bitumen Felt Over Roofs Consisting Of First And Third Courses Of Blown Bitumen 85/25 Or 90/15 Conforming To Is : 702 Applied Hot @ 1.45 Kg Per Square Metre Of Area For Each Course, Second Course Of Roofing Felt Type 3 Grade-I (Hessian Based Self Finished Bitumen Felt) And Fourth And Final Course Of Stone Grit 6Mm And Down Size Or Pea-Sized Gravel Spread At 6 Cubic Diameter Per Square Metre Including Preparation Of Surface But Excluding Grading Complete With Bitumen Felt (Hessian Base) Type 3 Grade I Conforming To Is : 1322. , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40 Mm Thik With 20Mm Nominal Size Stone Aggregate , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade One Or More Coats On Old Work. , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of Asbestos Sheet , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Providing Corrugated G.S. Sheet Roofing Including Vertical/Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275Gm/ M² , Lettering With Black Japan Paint Of Approved Brand And Manufacture , Making The Opening In Brick Masonry Including Dismantling In Floor Or Walls By Cutting Masonry And Making Good The Damages To Walls, Flooring And Jambs Complete, To Match Existing Surface I/C Disposal Of Mulba/ Rubbish To The Nearest Municipal Dumping Ground. , Carriage Of Material By Mechanical Transport Including, Loading, Unloading And Stacking :Earth, Building Rubbish Etc .(Rate Applicable After Deduction Of Void As Per Cpwd/Pwd Norms) Up To 2 Km , Providing Jack Hammer With Compressor Its Lead And Operator For Making Hole In Slab And Breaking R.C.C. And Exposing Existing Reinforcement And J.C.B Machine With Driver/Operator Fuel Hire Etc. Complete. , Providing & Fixing Top Cover Rolling Shutters , Providing & Fixing Ball Bearing For Rolling Shutters. , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Is: 4454 – Part 1 And M.S. Top Cover Of Required Thickness For Rolling Shutters.80X1.20 Mm M.S. Laths With 1.20 Mm Thick Top Cover. , Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters, Exceeding 10.00 Sqm And Upto 16.80 Sqm In The Area. , Dewatering By Pump Of Capacity 5/7.5 Hp With 4Meter Sump And 50Meter Pipe Length Including Installation, Operator /Helper ,Desiel/ Fuel Etc. As Per Direction Of Engineer In Charge. , Repair Of Rooling Shutter Through Repairing Of All Part Of It Including Required Size M.S. Laths ,Interlocked Together Their Enteir Length And Jointed Together At The End By Locks Mounted On Specially Designed Pipe Shaft With Breackets ,Side Guides And Arrangements For Inside And Out Side Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adeqate Strength Conforming To Is:4454-Part 1 And M.S. Top Cover Of Requierd Thickness For Rolling Shutter. 80X1.20Mm M.S. Laths With 1.20 Mm Thick Top Cover .Including All T&P And Manpower Complete. , Welding By Gas Or Electric Plant Including Transportation Of Plant At Site Etc. Complete. , Structural Steel Work In Single Section, Fixed With Or Without Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Without Applying A Priming Coat Of Approved Steel Primer All Complete. , Same As Above Item But Material Shall Be Provided By Department To The Contractor Free Of Cost. , Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheetfixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Dia G.I.Limpet And Bitumen Washers Complete. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6 Mm Angle Iron And 3 Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer.Using M.S. Angels 40X40x6 Mm For Diagonal Braces
Contract Date: Ref. Documents Contract Value : 31.38 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
4.
Housing Urban and Rular Development #11432178 Price Bid
Tender for Excavation In Foundation For Retaining, Breast Walls Etc, In All Types Of Soils And Rocks Including All Lead, Lift And Disposal Of Surplus Material As Per Direction Of Engineer - In - Charge, As Per Drawing And Technical Specifications Clause 305.1 Of Mord Specifiction , Removal Of Unsuitable Soil With Disposal Upto 1000 M Removal Of Unsuitable Soil Including Excavation, Loading And Disposal Upto 1000 M Lead But Excluding Compaction Ground Supporting Embankment Subgrade Replacement By Suitable Soil, Which Shall Be Paid Separately As Per Clause 303.5.2 As Per Technical Specification Clause 302.3.11 , Concrete With Cement, Coarse Sand And 40 Mm Gauge Stone Ballast In Proportion 1:4:8 In Foundations And Floors Including Supply Of All Material, Labour And T&P Etc. Required Forproper Completion Of The Work. As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 , Random Rubble Stone Masonry Laid In 1:6 Cement And Sand Mortar, In Breast Walls, Retaining Walls, Parapets, Scuppers, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Complete As Per Drawing And Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction , Random Rubble Stone Masonry Laid Dry, In Breast Walls, Retaining Walls, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Complete As Per Drawing And Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction , Hand Packed Stone Filling In Back Of Wallls Including Cost Of All Materials, Royality, T&P Etc. Complete As Per Direction Of Engineer-In- Charge. (As Per Pwd Uttarakhand Specifications) , Providing Weepholes In Brick Masonry/Stone Masonry, Lain / Reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(V):20(H) Towards Drawing Face Complete As Per Drawing And Technical Specification Clauses 614, 709, 1204.3.7 , Excavation In Hilly Areas In Ordinary Rock By Mechanical Means Not Requiring Blasting (With Out Dozer) Excavation In Hilly Area In Ordinary Rock Not Requiring Blasting By Mechanical Means Without Using Dozer Including Cutting And Trimming Of Slopes And Disposal Of Cut Material With A Lift Upto 1.5 M And Lead Upto 20 M As Per Clause 1603.2. , Providing And Laying Of Stone Set Pavement Over 2.5 Cm Thick Bedding Layer Of Plain Cement Concrete 1:2:4 Which Shall Further Be Placed Over 10 Cm Thick Dry Stone Kharanja Or Crushed Stones Base Over A Prepared Subgrade As Per Drawings And Technical Specifications. The Size Of Stones Shall Not Be Less Than 20Cm X 20Cm And Thickness Of Stones Shall Vary From 10Cm To 15 Cm. The Work Includes Filling Of Joints With Plain Cement Concrete 1:2:4 As Per The Standard Drawings And Instructions Of The Engineer-In-Charge. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 6.4.1 Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 (1 Cement: 6 Fine Sand) - Outer Plaster , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : 13.41.1 New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Seamless Type Tubes , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggreentrance Gate 20 Mm Nominal Size Derived From Natural Sources) , Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggreentrance Gate 20 Mm Nominal Size) Upto Plinth Level With : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggreentrance Gate 20 Mm Nominal Size Derived From Natural Sources) , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Abutments, Posts And Struts , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers With Water Proof Ply 12 Mm Thick , Random Rubble Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like. Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Pointing On Stone Work With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) : Raised And Cut Pointing , Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 12 Mm Thick , French Spirit Polishing : Two Or More Coats On New Works Including A Coat Of Wood Filler , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg / M3, 50Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm) @ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Flashings/ Aprons.( Upto 600 Mm) , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Gutter (600 Mm Over All Girth) , Manufacturing, Supplying And Fixing Retro Reflective Sign Boards Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity Encapsulated Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iv Of Astm-D 4956-01 In Blue And Silver White Or Other Colour Combination Including Subject Matter, Message (Bi-Lingual), Symbols And Borders Etc. As Per Irc ; 67:2001, Pasted On Substrate By An Adhesive Backing Which Shall Be Activated By Applying Heat And Pressure Conforming To Class -2 Of Astm-D-4956-01 And Fixing The Same With Suitable Sized Aluminium Alloy Rivets @ 20 Cm C/C To Back Support Frame Of M.S. Angle Iron Of Size 25X25x3 Mm Along With Theft Resistant Measures, Mounted And Fixed With 2 Nos. M.S. Angles Of Size 35X35x5 Mm To A Vertical Post Made Up To M.S. Tee Section Ismt 50X50x6 Mm Welded With Base Plate Of Size 100X100x5 Mm At The Bottom End And Including Making Holes In Pipes, Angles Flats, Providing & Fixing M.S. Message Plate Of Required Size, Steel Work To Be Painted With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade And Of Approved Brand & Manufacture Over Priming Coat Of Zinc Chromate Yellow Primer (Vertical Ms-Tee Support To Be Painted In Black And White Colours).Backside Of Aluminium Sheet To Be Painted With Two Or More Coats Of Epoxy Paint Over And Including Appropriate Priming Coat Including All Leads And Lifts Etc. Complete As Per Drawing, Specification And Direction Of Engineer-In-Charge. 16.59.1 Mandatory/ Regulatory Sign Boards Of 900 Mm Diametre With Support Length Of 3750 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 2.6.1 All Kinds Of Soil , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M , Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone - Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth , Providing And Fixing Plain Lining With Necessary Screws/Nuts & Bolts/ Nails, Including A Coat Of Approved Primer On One Face, And Fixed On Wooden /Steel Frame Work, Complete As Per Direction Of Engineer-In- Charge (Frame Work Shall Be Paid For Separately). 12 Mm Thick Commercial Ply Conforming To Is : 1328 Bwr Type , Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg / M3, 50Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm) @ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Providing And Fixing Of External Wall System On Light Gauge Steel Frame Work With Outer Face Cement Boards As Per Standard Sizes Fixed With Self-Drilling / Taping Screws / Fasteners @ 60 Cm C/C Of Approved Make. A Groove Of 2 Mm To 3 Mm Shall Be Maintained And Grooves Shall Be Sealed With Silicon Based Sealant. The Board Shall Be Fixed In A Staggered Pattern. Screws Shall Be Of Counter Sunk Rib Head Of 1.60 Mm To 4 Mm Thick Or 8 To 10 Gauge Of Length Varying From 25 To 45 Mm And. Internal Face 12.5 Mm Thick Gypsum Plaster Board Fixed On Cement Board As Per Standard Sizes Fixed With Self- Drilling / Taping Screws / Fasteners @ 60Cm C/C Of Approved Make, Proper Taping And Jointing To Be Done Using Fiber Mesh Tape And Epoxy And Acrylic Based Jointing Compound For Seamless Finish.(Cost Of Frame Work To Be Paid For Separately) Outer Face- Outer Face Having 6 Mm Thick Fiber Cement Board Type A, Category-Iv As Per Is:14862:2000 Fixed On 9 Mm Thick Fiber Cement Board, Type A, Category-Iv As Per Is:14862:2000 (High Pressure Steam Cured) Inner Face- 12.5 Mm Thick Gypsum Plaster Board Conforming To Is 2095:2011 Fixed On 8 Mm Thick Fibre Cement Board Of Type B, Category-Iii As Per Is:14862:2000 (High Pressure Steam Cured) , Providing And Fixing Internal Wall Panels On Light Gauge Steel Frame Work With 12.5 Mm Thick Gypsum Plaster Board Conforming Is 2095:2011 Fixed On Cement Board As Per Standard Sizes Fixed With Self-Drilling / Taping Screws / Fasteners @ 60 Cm C/C Of Approved Make, Screws Shall Be Of Counter Sunk Rib Head Of 1.60 Mm To 4 Mm Thick Or 8 To 10 Gauge Of Length Varying From 25 To 45 Mm. Proper Taping And Jointing To Be Done Using Fiber Mesh Tape And Epoxy And Acrylic Based Jointing Compound For Seamless Finish.(Cost Of Frame Work To Be Paid For Separately Cement Fiber Board 8 Mm Thick Of Type B, Category Iii As Per Is 14862:2000 (High Pressure Steam Cured) , Providing And Fixing In All Exterior Face Panels Breathable Vapour Barrier Underneath The Cement Fiber Board As Per National Building Code 2009 Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular/ L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 10.15.1 Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size , Providing And Fixing Pressed Steel Door Frames Conforming To Is: 4351, Manufactured From Commercial Mild Steel Sheet Of 1.60 Mm Thickness, Including Hinges, Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25 Mm, Or Base Ties Of 1.60 Mm, Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Including M.S. Pressed Butt Hinges 2.5 Mm Thick With Mortar Guards, Lock Strikeplate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface As Directed By Engineer In-Charge: Profile B Fixing With Carbon Steel Galvanised Dash Fastener Of Required Dia And Size (To Be Paid For Separately) , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding , Providing And Fixing Fly Proof Galvanized M.S. Wire Gauge To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia 0.63 Mm All Complete. With 12 Mm Mild Steel U Beading (Mosquito Jali). , Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 10.30.1 4.0 Mm Thick Glass Panes , Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378) - 125 Mm , Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378) - 250X10 Mm , Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete (Copper Oxidised As Per Is 1378) - 300X16 Mm , Providing And Fixing Isi Marked 85X42 Mm Oxidised M.S. Pull Bolt Lock Conforming To Is : 7534 With Necessary Screws Bolts, Nut And Washers Etc. Complete (Copper Oxidised As Per Is 1378). , Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade With Necessary Screws Etc. Complete. Single Rubber Stopper , Providing And Fixing Ptmt Door Catcher Of Length 72 Mm And Dia. Of 42 Mm With Suitable Washers Weighing Not Less Than 33 Gms , Providing And Laying Vitrified Tiles In Floor With Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately). Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is: 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately). Size Of Tile 600X600 Mm , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , Supplying And Filling Of Earth By Mechanical Transport Including Loading, Unloading & Stacking Beyond 5Km Upto 10Km & Beyond 10Km Upto 20Km (Including All) , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level. Concrete Of M30 Grade With Minimum Cement Content Of 350 Kg /Cum , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry , 12 Mm Cement Plaster Of Mix: 1:6 (1 Cement: 6 Fine Sand) - Inner Plaster , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screw , Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side /Top /Centre Hung, With Beading And All Members Such As F7d,F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Riming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, (Sectional Weight Of Only Steel Members Shall Be Measured For Payment). 10.11.1 Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete , Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sq.M Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sq M Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sq M) , Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : (A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. (B) Second Layer Of Slurry Of Cement @ 0.242 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
Jammu And Kashmir View Result →
6.
Public Administrative Department #11418578 AOC
Tender For To carry out various development and maintenance works in Adarsh ​​School in Ward No. 36-Providing and fixing colour coated Zincalume (R) AZ150 (min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon)coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center tocenter. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) with COLORBOND ( R ) steel quality super durable polyester paint ( SSR Item No : 38.34 ) (PMC Bhavan ) Unique No (15655) Rate List Year (2024-2025) ITEM NO : 2 Providing and fixing partition of welded mesh of 3 mm dia. wires 50 mm x 25 mm size mesh including integrated non teak seasoned wood frame 80 x 50 mm of vertical and horizontal scantling and finishing with oil painting 3 coats etc. complete ( SSR Item No : 39.27 ) (PMC Bhavan ) Unique No (15701) Rate List Year (2024-2025) ITEM NO : 3 Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.Number: As directed by Engineer- in-charge. ( SSR Item No : 23.09 ) (PMC Bhavan ) Unique No (15305) Rate List Year (2024-2025) ITEM NO : 4 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. ( SSR Item No : 23.01 ) (PMC Bhavan ) Unique No (15297) Rate List Year (2024-2025) ITEM NO : 5 Oil paint glass finish : Providing and applying two coats of oil paint glass finish bituminious paint of approved colour to new structural steel work and iron work in buildings including scaffolding if necessary, cleaning and preparing the surface etc. complete ( SSR Item No : 63.2 ) (PMC Bhavan ) Unique No (16692) Rate List Year (2024-2025) ITEM NO : 6 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. ( SSR Item No : 26.33 ) (PMC Bhavan ) Unique No (15352) Rate List Year (2024-2025) ITEM NO : 7 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. ( SSR Item No : 27.01 ) (PMC Bhavan ) Unique No (15370) Rate List Year (2024-2025) ITEM NO : 8 Providing internal cement plaster 20mm. thick in Single coats cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. ( SSR Item No : 32.08 ) (PMC Bhavan ) Unique No (15443) Rate List Year (2024-2025) ITEM NO : 9 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. SSR Item No : 32.11 ) (PMC Bhavan ) Unique No (15444) Rate List Year (2024-2025) ITEM NO : 10 Providing and laying matt finish ceramic tiles of having size 30 cm 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. SSR Item No : 33.24 ) (PMC Bhavan ) Unique No (15492) Rate List Year (2024-2025) ITEM NO : 11 Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. SSR Item No : 33.25 ) (PMC Bhavan ) Unique No (15493) Rate List Year (2024-2025) ITEM NO : 12 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track sect ion 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. SSR Item No : 39.37 ) (PMC Bhavan ) Unique No (15711) Rate List Year (2024-2025) ITEM NO : 13 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item Number 15 to 18 prior approval of Superintending Engineer will be necessary ( SSR Item No : 35.26 ) (PMC Bhavan ) Unique No (15576) Rate List Year (2024-2025) ITEM NO : 14 Wall Painting art work : painting artistic work on any type of surface and at any height using scaffolding with skilled artists as per the instructions of site incharge.measurement will be as per actual max.size of art.rate for background apex paint and lettring will be paid seperately ( SSR Item No : 63.4 ) (PMC Bhavan ) Unique No (16694) Rate List Year (2024-2025) ITEM NO : 15 painting various letters /sentences in any languages on any surface using weather shield paint from skilled painter upto 10feet ht.from existing grond level.for measurements minimum height of letter will be considered.background paint if required will be paid seperately ( SSR Item No : 63.5 ) (PMC Bhavan ) Unique No (16695) Rate List Year (2024-2025) ITEM NO : 16 Providing and fixing 12 mm thick waterproof plywood ( durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI) ) ( SSR Item No : 62.11 ) (PMC Bhavan ) Unique No (16542) Rate List Year (2024-2025) ITEM NO : 17 Providing and fixing 19 mm thick waterproof plywood ( durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI) ) ( SSR Item No : 62.12 ) (PMC Bhavan ) Unique No (16543) Rate List Year (2024-2025) ITEM NO : 18 Laminates sheets 1 mm thick : Providing and fixing laminates sheets as per company specification and fix it with fevicol – Recommended companies- formica, Royal touch, Marino , Green lam , Euro. ( 1 mm thick laminates sheets ) ( SSR Item No : 62.23 ) (PMC Bhavan ) Unique No (16566) Rate List Year (2024-2025) ITEM NO : 19 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. SSR Item No : 41.40 ) (PMC Bhavan ) Unique No (15815) Rate List Year (2024-2025) ITEM NO : 20 Providing & fixing 1/2”,1/4”to 1” tk Teakwood leaping patti including polishing etc completed. SSR Item No : 62.27 ) (PMC Bhavan ) Unique No (16570) Rate List Year (2024-2025) ITEM NO : 21 Providing & fixing 3” 5” size Aluminum Brackets/Runners as per site in charge instructions etc. completed.(Including all necessaryFittings) SSR Item No : 62.28 ) (PMC Bhavan ) Unique No (16571) Rate List Year (2024-2025) ITEM NO : 22 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) Hinges SSR Item No : 62.29-A ) (PMC Bhavan ) Unique No (16572) Rate List Year (2024-2025) ITEM NO : 23 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) . Handles SSR Item No : 62.29-B ) (PMC Bhavan ) Unique No (16573) Rate List Year (2024-2025) ITEM NO : 24 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) . Locks (For cupboards & wardrobes) SSR Item No : 62.29-C ) (PMC Bhavan ) Unique No (16574) Rate List Year (2024-2025) ITEM NO : 25 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) . Rubber roller (Heavy Duty) SSR Item No : 62.29-D ) (PMC Bhavan ) Unique No (16575) Rate List Year (2024-2025) ITEM NO : 26 Curtains Providing clothes for curtain of Bombay Dyeing/Binni/Mafatlal etc brands, stitching as per required size with Frill (Zaller) & fixing at required places ( including rings ) Note:-Measurement would be taken as per actual length of window& default width ( i.e . 48” panha). Curtain (Material Synthetic Clothes & cost of clothes starting from Rmt Rs 250/- onwards) SSR Item No : 62.30-B ) (PMC Bhavan ) Unique No (16577) Rate List Year (2024-2025) ITEM NO : 27 Stainless Steel Pipe curtain rod . Providing & fixing of SS pipe curtain rods including Brackets as per site in charge instructions & all necessary Fittings etc. completed SSR Item No : 62.31-A ) (PMC Bhavan ) Unique No (16578) Rate List Year (2024-2025) ITEM NO : 28 Providing and fixing coloured glazed earthenware lipped flat back/corner type urinal with PVC 5 liters flushing cistern with fittings,capacity with fittings, inlet pipe and stop tap, brackets for fixing the cistern, P.V.C. flush pipe with fittings including lead soil pipe, lead trap and soil pipe connection up to the outside face of the wall. SSR Item No : 41.61 ) (PMC Bhavan ) Unique No (15836) Rate List Year (2024-2025) ITEM NO : 29 Providing and fixing Orissa type white glazed earthenware water closet pan of size 260mm x 440mm x 580mm with approved make Slim wall hung cistern with installation kit including S or P trap with cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc.complete. SSR Item No : 48.42 ) (PMC Bhavan ) Unique No (16111) Rate List Year (2024-2025) ITEM NO : 30 PVC Carpet Providing 1.5 mm thick pvc carpet of approved design n color & fixing at site as per site in charge instructions etc. completed.Note: - Dimensions would be considered as per actual carpet size fixed at site. SSR Item No : 62.33 ) (PMC Bhavan ) Unique No (16581) Rate List Year (2024-2025) ITEM NO : 31 Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. SSR Item No : 35.23 ) (PMC Bhavan ) Unique No (15573) Rate List Year (2024-2025) ITEM NO : 32 Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. SSR Item No : 35.12 ) (PMC Bhavan ) Unique No (15563) Rate List Year (2024-2025) ITEM NO : 33 Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. SSR Item No : 36.11 ) (PMC Bhavan ) Unique No (15587) Rate List Year (2024-2025) ITEM NO : 34 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete SSR Item No : 46.19 ) (PMC Bhavan ) Unique No (16026) Rate List Year (2024-2025)
Contract Date: Feb 28, 2026 Contract Value : 20.86 Lakh
Local Bodies No of Bidders 6
Maharashtra View Result →
7.
Public Administrative Department #11417771 Price Bid
Providing Civil Works In Ward No.14 Kalbhor Nagar, Moannagar And Other Areas (Year 2025-26)-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for thefoundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge. Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, f oundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No.: Bd.F.17, Page No. 306 Ground Floor Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means Removing and Transporting of excavated / demolished material within PCMC limit including loading, unloading, stacking the material as directed by Engineer-in-charge etc. complete. (For Lead 10.0 Km). Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with WITHOUT SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:2:4 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:2:4 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer without SCADA with fine agreegates of required specifications (Crushed sand VSI grade ) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material Granular Sub Base Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material (Note- As per circular issued by Hon. city engineer PCMC , vide civil/CE/TS/23/16/2023.Date 21/04/2023 .Rate is reducedby 20% as material brought from PCMCs C and waste processing plant.) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material Note- As per circular issued by Hon. City Engineer, PCMC vide circular no.Civil/CE/TS/23/16/2023 Dated 21/04/2023, rate is reduced to 20% as material is to be brought from C and D work processing plant Supplying hard murum/ kankar at the road site, including conveying and stacking complete. Spreading hard murum/ soft murrum/ gravel or kankar for side width complete Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. Ground Floor Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel st anchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Lift 0.0 to 3.8 M Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. PARDI of required thickness including centering, formwork, cover blocks, laying/pumping ,compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With Crushed sand VSI Grade. Spec. no.:- Bd.F.11 Page No. 304 and B.7, Page No. 38 Ground Floor Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Lift 0.0 to 3.8 M Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. Removing the tar or coba and disposing of the material as directed etc. complete. Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering to 10 Square Metre Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor Lift 0.0 to 3.8 M Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Providing and applying two coats (exterior quality) of flat oil paint of approved colour and shade to the plastered surface in buildings and workshops including scaffolding if necessary, cleaning the surface and preparing surface etc. complete. (excluding primer coat) Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Ground Floor Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. Ground Floor Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 etc
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 8
Maharashtra View Result →
8.
Water Resources and Irrigation #11342285 AOC
Amrut-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipment For 107 Mld Sewerage Treatment Plant At Muttathara-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipments For 107 Mld Sewerage Treatment Plant At Muttathara-Sewerage Work- 1 SUPPLY, ERECTING AND COMMISSIONING OF PUMP SETS 2 OD149149/2023-2024:Supply, Erecting and Commissioning of 75 HP non clog pump set for RAS (Head – Up to 20 M) 3 OD149154/2023-2024:Supply, Erection and Commissioning of 5 HP non clog pump set for WAS (Total Head :14 M ) 4 OD149153/2023-2024:Supply, Erecting and Commissioning of 5 HP centrifugal dewatering pump set for RAS 5 OD17699/2025-2026:Supply, Erecting and Commissioning of80 HP Submersible pump set for inlet(Head : Up to 20 M) 6 OD18102/2025-2026:Supply, installation, and commissioning of minimum 100 LPH RO water purifier of standard make with 304-grade stainless steel skid and housing, comprising multi-stage purification system including pre-filter, sediment filter, activated carbon filter, RO membrane, UV disinfection unit, auto-flush system, and mineral cartridge; suitable for continuous commercial use and delivering safe, high-quality drinking water. 7 OD18758/2025-2026:Supply of 10 HP portable submersible sludge pump, 3-phase, suitable for handling slurry and sewage, maximum head up to 20 meters, solid handling capacity up to 50 mm, abrasion-resistant impeller, thermal protection, 15 m power cable, and 30 meters of heavy-duty discharge hose (100 mm dia) with quick couplings. 8 Supply and installation soft starter and motorized chain pulley 9 OD149170/2023-2024:Supply of motorized chain pulley block with 3-ton lifting capacity and 10-meter lift height, featuring electric motorized operation with electromagnetic or disc brake system, pendant control for easy operation, limit switches for safety, and overload protection, conforming to IS/ISO standards. 10 OD16970/2025-2026:Supply and installation of soft starter for MCC unit ( For 60 HP motor XS4000,115A,M200-525VACC110/ 220VAC), MNX140 3P 240V CONTACTOR and SEMI CONDUCTOR FUSE 170M3015 11 OD18097/2025-2026:Supplying, fixing, and testing 50W LED hanging type well glass light, weatherproof (IP65) 12 OD18264/2025-2026:Supply and installation of 10-meter hot-dip galvanized double-arm octagonal street light pole with 2×120W LED luminaires, including internal wiring, weatherproof junction box, connections, and earthing. Complete with foundation bolts and RCC pedestal. Includes supply, erection, and commissioning 13 Installation of CCTV camera 14 OD16801/2025-2026:Supplying & fixing HIKVISION 5 MP Varifocal IP Bullet Camera CAMERA 15 OD16892/2025-2026:Supplying, fixing and commissioning 4MP IP DOME CAMERA 16 OD16891/2025-2026:Supplying, fixing and commissioning HIKVISION 4MP IP BULLET CAMERA 40M 17 OD16890/2025-2026:Supplying, fixing and commissioning HIKVISION 32CH NVR 18 OD16889/2025-2026:Supplying, fixing and commissioning 8 PORT POE SWITCH 19 OD16888/2025-2026:Supplying & fixing 6U RACK & ACCESSORIES 20 OD16887/2025-2026:Supplying & fixing 9U RACK& ACCESSORIES 21 OD16886/2025-2026:Supplying & fixing CAMERA BOX 22 OD16885/2025-2026:Supplying & fixing CAT6 CABLE & PIPING (including excavation) 23 OD16884/2025-2026: Supplying and fixing pole with all accessories. 24 OD16920/2025-2026:Supplying and fixing 55-inch, 4K, LED, Smart TV (Samsung/LG/Sony) 25 OD16919/2025-2026:Supplying & fixing RECEIVER & TRANSMITTER UNIT 26 OD16918/2025-2026:Supplying & fixing L & T EXTENSION 5MTR 27 OD16917/2025-2026:Supplying & fixing 5 PORT GIGABYTE SWITCH 28 OD16916/2025-2026:Supplying & fixing HDMI CABLE 3MTR 29 OD16915/2025-2026:Supplying & fixing RACK & PIPE ACCESSORIES, 30 OD16914/2025-2026:INSTALLATION CHARGE FOR CAMERA& NVR 31 OD16913/2025-2026:Supplying & installation of rack 32 New Road formation: Tarring inside STP compound 33 3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m 34 4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method 35 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 36 5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means. 37 5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. 38 OD18679/2025-2026:Providing 40mm premixed chipping carpet over BT surface with departmental broken stones after thoroughly cleaning the base with wire brushes, brooms and applying a priming coat of hot bitumen @2.50Kg/10m2 and spreading the hot premix of 0.32m3 of 24mm, 0.22m3 of 12mm departmental metal mixed with 22.08Kg of bitumen per 10m2, rolling to dense surface, then spreading the seal coat comprising of 0.09m3 of 6mm metal mixed with 8.64kg of bitumen per 10m2 and rolling again including cost of bitumen, fuel, hire charges machineries etc. complete excluding the cost of 24mm ,12mm ,6mm metal(Total usage of bitumen 33.22 Kg per 10m2) (I.R.C 3.4.2) 39 OD18716/2025-2026:Supplying and stacking 24mm hard blue granite broken stone in standard heaps-for measurement(IRC 3.2. 1.a) 40 55.2:Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 41 55.3:Supplying and stacking 6mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 42 Infrastructure Improvement Works at STP 43 OD17712/2025-2026:Supply and installation of UV-resistant HDPE with 12mm mesh ( 2meter height) for durability. Support poles are galvanized iron pipes (2-inch dia, 6 ft height) for stability. Stainless steel clamps & UV-resistant plastic ties ensure secure fitting. Concrete footing with excavation and earthwork provides pole stability. Skilled labor ensures proper installation 44 OD17711/2025-2026:Supply and spray a non-toxic, bio-friendly herbicide or a selective herbicide, with an application rate of 5 to 10 liters per hectare, ensuring effective weed control over an area of 1 hectare. 45 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 46 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 47 4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) 48 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 49 5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars 50 OD17710/2025-2026:Supply & installation of high-quality polyester sun control film with UV-blocking, heat resistance (99% UV, 60% heat rejection), 2–4 mil thickness, bubble-free installation, and 5-year warranty. 51 OD17709/2025-2026:Fire extinguishers (10L dry powder and 4.5kg CO₂) shall be installed as per IS: 2190 with inspection cards. Fire buckets with MS stands, safety posters, and caution notices in Malayalam and English shall be provided for compliance. 52 Providing roofing for DG, Inlet outdoor panels and mechanical screener 53 100.98.1009:Engaging Fitter ( grade 1). 54 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 55 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 56 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 57 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 58 50.12.1.1:Providing & fixing PVC corrugated roofing sheets of good quality up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8 mm dia G. I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 59 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 60 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 61 Replacement of leaking flanged pipes inside the inlet well 62 OD17790/2025-2026:Supply, conveyance, and fixing of 300mm double flanged DI K9 pipe, including scaffolding, fabrication if required (cutting, flange welding), and providing necessary fittings, nuts, bolts, rubber gaskets, and insertion rubber sheets for proper and safe installation at site. 63 OD17835/2025-2026:Dismantling existing 300 mm DI pipes carefully using crane/manual handling with all necessary safety measures, and stacking the removed materials within 50 meters as directed by the Engineer-in-Charge 64 Provision forEntry of Trucks from Rear Side of STP 65 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 66 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 67 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 68 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 69 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 70 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 71 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 72 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 73 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 74 13.82.1:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.One coat 75 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 76 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 77 Security room (4m x 3m) at back entrance of STP 78 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 79 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 80 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 81 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 82 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 83 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 84 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 85 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 86 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 87 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 88 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 89 OD17944/2025-2026:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including MS grill with suitable spacing and ISI marked M.S pressed butt hinges bright finished of required size with necessary locking arrangements. 90 OD17947/2025-2026:Electrical work including internal lighting, fan, switches, DB, concealed wiring, and one external LED light with pole/bracket for night visibility, complete with connections, fittings, and testing as per direction of Engineer-in-Charge. 91 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Contract Date: Jun 23, 2026 Contract Value : 2.52 Crore
Local Bodies No of Bidders 1
9.
Public Administrative Department #11306281 AOC
Tender For Various development Works At Swami Ramdev Maharaj Sports Complex.-ITEM NO: 1 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete (SSR Item No: 46.19) (PMC Bhavan) Unique No (16026) Rate List Year (2024-2025) ITEM NO: 2 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. (SSR Item No: 46.12) (PMC Bhavan) Unique No (16019) Rate List Year (2024-2025) ITEM NO: 3 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means (SSR Item No. 21.02) (PMC Bhavan) Unique No (15202) Rate List Year (2024-2025) ITEM NO:4 Transportation of material obtained from excavation including soil, Cu.M rubble, bricks, RCC concrete, kerb stones, steel railing, iron pipes, channels etc. Obtained from excavation, dismantling, loading in a Truck of minimum 5 Cu M capacity or designed capacity and transporting within the municipal limits or any designated place, unloading, stacking or spreading of material etc. complete. As directed by Engineer In charge (SSR Item No: 78.36) (PMC Bhavan) Unique No (17223) Rate List Year (2024-2025) ITEM NO: 5 Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. (SSR Item No: 21.38) (PMC Bhavan) Unique No (15233) Rate List Year (2024-2025) ITEM NO: 6 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. (SSR Item No: 21.37) (PMC Bhavan) Unique No (15232) Rate List Year (2024-2025) ITEM NO: 7 Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (SSR Item No: 24.10) (PMC Bhavan) Unique No (15312) Rate List Year (2024-2025) ITEM NO: 8 Supply of Titanium FIFA Certified Soccer Turf EB-50 MM Series Grass:- Material /Dtex: PE12000 Structure Monofilament Yarn Pile Height (mm): 50 10cm): 15 Stitch rate (Per 10 cm):15 Guage (inch): 5/8 Stitches/m2:9450 Roll (Mtr) Width x Length: 4 or 2 x 30,5 Breaking: Triple Layers High wear resistance & perfect ball roll properties Economical System & UV Resistance Creative Technology & Quick Construction Natural & Beautiful appearance Good performance Reinforced Playability 3 years Turf Warranty 1 year Glue Warranty SBR Black Rubber Granuels in size of 8mm to 2.4mm 10kg/m2 Silica Sand 18kg/m2 Silica Sand 18kg/m2 Tape & European PU glue with hardner (Ration 2:1) According to Layout Colour-Green Plan Installation Installation of Turf with inhouse trained installation team Infill of Silica Sand & Granules Brushing & Line Marking. Including Transportation (SSR Item No: 72.4) (PMC Bhavan) Unique No (17099) Rate List Year (2024-2025) ITEM NO: 9 Cricket Pitch Turf Providing & Fixing Full Pitch Synthetic Turf 15 mm thk. of size 30 M X 2.75 M. over Tremix surface (Excluding Tremix) with suitable arrangement/adhesive as per manufacturers specification rolling with hand roller for removing air gaps as directed by Engineer In charge etc. complete. (SSR Item No: 72.1) (PMC Bhavan) Unique No (17096) Rate List Year (2024-2025) ITEM NO: 10 Providing & Fixing nylon net 35mmx35mmx1.75mm including top and side. (SSR Item No. 72.2) (PMC Bhavan) Unique No (17097) Rate List Year (2024-2025) ITEM NO: 11 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. (SSR Item No: 42.52) (PMC Bhavan) Unique No (15904) Rate List Year (2024-2025) ITEM NO: 12 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (SSR Item No: 23.01) (PMC Bhavan) Unique No (15297) Rate List Year (2024-2025) ITEM NO: 13 Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. (SSR Item No: 23.12) (PMC Bhavan) Unique No (15307) Rate List Year (2024-2025) ITEM NO: 14 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters (SSR Item No: 42.53) (PMC Bhavan) Unique No (15905) Rate List Year (2024-2025) ITEM NO 15 Providing and fixing colour coated Zincalume (R) AZ150 (min 150 gms/sq.mt total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT) (0.5 mm TCT), Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon)coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coal on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fiuting in the five pan at nominal 180-250 mm center to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) with COLORBOND (R) steel quality super durable polyester paint (SSR Item No: 38.34) (PMC Bhavan) Unique No (15655) Rate List Year (2024-2025) ITEM NO: 16 Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints. raking out joints, watering and scaffolding etc. Complete (SSR Item No. 27.13) (PMC Bhavan) Unique No (15381) Rate List Year (2024-2025) ITEM NO: 17 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (SSR Item No: 32.11) (PMC Bhavan) Unique No (15444) Rate List Year (2024-2025) ITEM NO: 18 Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt. (SSR Item No: 44.10) (PMC Bhavan) Unique No (15994) Rate List Year (2024-2025)
Contract Date: Jun 19, 2026 Contract Value : 33.26 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
10.
Public Administrative Department #11306280 AOC
To carry out various remaining development works at Vitthal Tupe Sports Complex Hadapsar=-ITEM NO : 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means ( SSR Item No : 21.02 ) (PMC Bhavan ) Unique No (15202) Rate List Year (2024-2025) ITEM NO : 2 Transportation of material obtained from excavation including soil, rubble,bricks,RCC concrete, kerb stones, steel railing, iron pipes, channels etc. Obtained from excavation, dismantling, loading in a Truck of minimum 5 Cu M capacity or designed capacity and transporting within the municipal limits or any designated place, unloading, stacking or spreading of material etc. complete. ( SSR Item No : 2.39 ) (PMC ROAD ) Unique No (114) Rate List Year (2023-2024) ITEM NO : 3 Supplying hard murum/ kankar at the road site, including conveying and stacking complete. ( SSR Item No : 2.29a ) (PMC ROAD ) Unique No (103) Rate List Year (2023-2024) ITEM NO : 4 Spreading hard murum/ soft murrum/ gravel or kankar for side width complete ( SSR Item No : 2.30 ) (PMC ROAD ) Unique No (105) Rate List Year (2023-2024) ITEM NO : 5 Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. ( SSR Item No : 2.31 ) (PMC ROAD ) Unique No (106) Rate List Year (2023-2024) ITEM NO : 6 Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete. ( SSR Item No : 42.11 ) (PMC Bhavan ) Unique No (15863) Rate List Year (2024-2025) ITEM NO : 7 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. ( SSR Item No : 42.12 ) (PMC Bhavan ) Unique No (15864) Rate List Year (2024-2025) ITEM NO : 8 Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. N o t e : O n l y 8 5% r a t e i s p a y a b l e t i l l satisfactory hydraulic testing is given. The Bidder shall procure RCC pipes and chamber covers from following suppliers 1) M/S Sneh Precast 2) M/S Kalokhe pipes and precast industries 3) M/S Poona Concrete Company If bidder wish to supply RCC pipes and chamber covers other than above suppliers, then it is mandatory to take approval of supplier from concern department. Third party inspection of RCC pipes and chamber covers is mandatory and should be witnessed by EIL/IR CLASS/SGS. The cost of third party inspection should be borne by contractor. Class ‘NP-II 300 mm ( SSR Item No : 50.a vii ) (PMC Drainage ) Unique No (19058) Rate List Year (2024-2025) ITEM NO : 9 Providing and constructing on sewer line, B. B. masonry circular m a n h o l e w i t h c o n c e n t r i c cone 1.2 M dia. at bottom and 0.5 M dia. at top and upto a depth of 1.50 M with 23 cm. thick and 35cm thick brickwork for balanced depth in 230 X 100 X 75 mm brick masonry in CM 1:5 proportion plastering both inside and outside in CM 1:3 with cement finish, half round RCC pipe of required dia excluding excavation including PCC1:3:6 in bed 100 mm thick , haunches and channels in 1:2:4 proportion concrete, finishing channels in smooth rendering, providing 100 mm thick 1:2:4 coping on the top of the masonry & below frame including providing and fixing approved make and quality S.F.R.C. frame and cover of 56 cm dia. heavy duty 275 kg. etc. complete as directed by Engineerincharge. Note : The rate of this item isinclusive of hydraulic testing of chamber. Providing and constructing on sewer, B. B. masonry circular manhole with concentric cone (as per attached drawing no.1) ( SSR Item No : 56 ) (PMC Drainage ) Unique No (19206) Rate List Year (2024-2025) ITEM NO : 10 Providing & Applying External Textured Paint + Applying Waterproofing Coat as per below steps 1) Cleaning + crack filling 2) 1coat of Waterproofing Chemical 3) 1 Coat Apex Duracast CrossTex (2mm Thk) 4) 2 Coat of Professional Premium Exterior Emulsion Apex including claning and preparing the existing surface and scaffolding if necessary ( SSR Item No : 63.13 ) (PMC Bhavan ) Unique No (16702) Rate List Year (2024-2025) ITEM NO : 11 Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. ( SSR Item No : 32.34 ) (PMC Bhavan ) Unique No (15466) Rate List Year (2024-2025) ITEM NO : 12 Water bound distemper : Providing and applying water bound distemper along with primer coats including scaffolding if necessary, cleaning and preparing the surface etc. complete Recommended companies: Asian, neroleck, Dulex ( SSR Item No : 63.1 ) (PMC Bhavan ) Unique No (16691) Rate List Year (2024-2025) ITEM NO : 13 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. ( SSR Item No : 46.42 ) (PMC Bhavan ) Unique No (1547) Rate List Year (2023-2024) ITEM NO : 14 House keeping : Cleaning Of Passage by wet and dry method including swipping, water, phenol, room freshener, acid and chemical cleaning, scrubber machine, Colin for glass cleaning, material and labour, etc. complete. ( including all windows, doors, tables etc. present in passage for one time cleaning) ( SSR Item No : 78.19 ) (PMC Bhavan ) Unique No (17191) Rate List Year (2024-2025) ITEM NO : 15 Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. ( SSR Item No : 35.23 ) (PMC Bhavan ) Unique No (15573) Rate List Year (2024-2025) ITEM NO : 16 Building (Bd-V : Water supply and sanitory fittings)Upvc sanitary pipes all 20 mm dia ( SSR Item No : 49.V-346 ) (PMC Bhavan ) Unique No (2314) Rate List Year (2023-2024) ITEM NO : 17 Flat back urinal-providing and fixing flat back urinal without flushing tank but including bracket for fixing urinals,inlet pipe,32mm dia pvc flush pipe and stop tap ,filling the gaps with white cement etc complete ( SSR Item No : 61.04 ) (PMC Bhavan ) Unique No (16484) Rate List Year (2024-2025) ITEM NO : 18 Building (Bd-V : Water supply and sanitory fittings)Gun Metal stop tap with crutch wheel 20mm ( SSR Item No : 49.V-31 ) (PMC Bhavan ) Unique No (17702) Rate List Year (2024-2025) ITEM NO : 19 Building (Bd-V : Water supply and sanitory fittings)Shower rose chromium plated brass 10cm ( SSR Item No : 49.V-177 ) (PMC Bhavan ) Unique No (17848) Rate List Year (2024-2025) ITEM NO : 20 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. ( SSR Item No : 23.01 ) (PMC Bhavan ) Unique No (15297) Rate List Year (2024-2025) ITEM NO : 21 Providing and fixing colour coated Zincalume (R) AZ150 (min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon)coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center tocenter. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) with COLORBOND ( R ) steel quality super durable polyester paint ( SSR Item No : 38.34 ) (PMC Bhavan ) Unique No (1155) Rate List Year (2023-2024) ITEM NO : 22 Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant with scada as per approved mix design, admixtures, transporting to site, spreading, laying with skid vibrator,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. ( SSR Item No : 5.03 ) (PMC ROAD ) Item Spec : (MORTH 602) Unique No (175) Rate List Year (2023-2024) ITEM NO : 23 Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete ( SSR Item No : 40.6 ) (PMC Bhavan ) Unique No (15777) Rate List Year (2024-2025) ITEM NO : 24 Providing and fixing self supporting steel roofing system for a Godown or alike made up of structural grade steel sheet of 912 millimeter width ( tolerance +/- 2 millimeter ), moulded at site using mechanical press dies to the desired curve and shape to form 605 millimeter wide interlocking panels . The interlocking panels shall be pressed to close the seam forming water tight joints for a span of 15.30 meter having arch rise as 3.06 meter, arch length 17.75 meter. The base material made up of imported galvalume steel complying to ASTM A792 having base metal thickness of 0.80 millimeter ( tolerace + / - 0.02 millimeter ) with alloy coating AZ 150 and paint coating of regular modified polyster , top coat 25 micron and bottom coat 12 micron as per approved colour , including fixing hangers , clamps etc.as may be necessary of Proflex standard, including fixing sky light of millimeter thick polycarbonate sheet of size 2’ x 7’ and turbo ventilator of 24’’diameter to be installed at every 30 feet along the length of roof including finishing, testing and cleaning etc. complete. ( SSR Item No : 38.41 ) (PMC Bhavan ) Unique No (15662) Rate List Year (2024-2025) ITEM NO : 25 Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish ( SSR Item No : 33.36 ) (PMC Bhavan ) Unique No (15504) Rate List Year (2024-2025) ITEM NO : 26 Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) ( SSR Item No : 39.20 ) (PMC Bhavan ) Unique No (15694) Rate List Year (2024-2025) ITEM NO : 27 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track sect ion 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. ( SSR Item No : 39.37 ) (PMC Bhavan ) Unique No (15711) Rate List Year (2024-2025) ITEM NO : 28 Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade complete. Spec. Number : As directed by Engineer-in-charge. ( SSR Item No : 23.11 ) (PMC Bhavan ) Unique No (15306) Rate List Year (2024-2025) ITEM NO : 29 BITUMINOUS CONCRETE WITH SCADA:- Providing and laying bituminous concrete using crushed aggregates of grading II, premixed with bituminous binder @ 6% per cent by weight of total mix and filler, transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction for 50 mm compacted thickness with specified grade of Bitumen,Excluding prime / tack coat. For Bitumen of specified grade -- USING Batch mix type hot mix plant with SCADA, Sensor Paver with scada, vibratory roller with scada.with Stone Dust filler with Stone Dust filler. (VG-30 bulk bitumen rates are considered ) ( SSR Item No : 3.48 ) (PMC ROAD ) Unique No (627) Rate List Year (2024-2025) ITEM NO : 30 Stamped Concrete :- Thin overlay approximately 1/32 to 5/16 (thicker application may be nessecery in some situations) of stamped concrete overlays over M-20 concrete of 100 mm thicksurface, interior, applied smooth,textured or stamped in various patterns and designs using stamps and seamless texture skins, then antiqued, chemically stained or integrally colored and sealed with the appropriate coating. Systems sealers or protective top coats according to the job conditions and specifications. (including the cost of M-20 concrete of 100 mm thickness) ( SSR Item No : 1.10 ) (PMC ROAD ) Unique No (204) Rate List Year (2023-2024) ITEM NO : 31 Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete ( SSR Item No : 27.13 ) (PMC Bhavan ) Unique No (15381) Rate List Year (2024-2025) ITEM NO : 32 Providing rough cast cement plaster externally in two coats with coloured cement finish to concrete/ brick/ stone masonry surfaces in all positions with base coat 12 to 15 mm. thick in C.M. 1:4 using gray cement and rough cast treatment 12 mm thick in proportion of 1:1 1/2:3 using colour pigment including scaffolding and fourteen days curing etc. complete. ( SSR Item No : 32.13 ) (PMC Bhavan ) Unique No (15446) Rate List Year (2024-2025)
Contract Date: Jun 22, 2026 Contract Value : 49.64 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
11.
Public Administrative Department #11300148 AOC
Tender For Construction Of Inspection Banglow, Guest House, Boundary Wall & Garage Near Suklai Head Works Under Extension, Renovation And Modernization Of (Erm), Sukla Irrigation Project Under Pmksy-Aibp For The Year 2021-22. , Construction Of Inspection Banglow, Guest House (Ground Floor). Earth Work : Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Pre Construction Anti - Termite Treatment : Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration , Brick Work : Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Plinth Protection : Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling And Dressing And Finishing The Top Smooth. , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow Cum Guest House (First Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Second Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Roofing : Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 B49grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester To Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Sound Proof : Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. , 8 Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Processto Give Stable Crystalline Structure With Minimumcompressive Strength 225 Kg/ Sq. Cm, Bending Strength100 Kg/Sq. Cm , Of Size 595X595 Mm, Having Perforationof Dia. 10 Mm With Minimum Perforated Area 18 % Withnon Woven Tissue On The Back Side, Having An Nrc( Noise Reduction Coefficient) Of 0.85, With 50 Mm Thickrockwool Of 48 Kg /Cum Backing , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per Manufacturers Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Inetrnal Electrification) Sub Head -I (Wiring) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. A) Group A , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , 6 X 1.5 Sq. Mm , 6 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 25 Mm , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3Pin 5/6 Socket Outlet , Sub Head - Ii (Mcb & Dbs ) Supplying And Fixin G Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator)8 Way, Double Door , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 215 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 4 Way (4 + 12), Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Bre Aker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40/63 A Tp , Sub Head-Iii (Fan,Fittings And Fixtures) Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Five Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc Motor) Not Less Than 32 W, Class Of Insulation B, 3 Nos Blade, 30 Cm Long Down Road, 2 Nos Of Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85 Air Delivery Minimum 215Cmm , 350 Rpm (Tolerance As Per Is:374-2019), Thd Less Than 10% Remote Or Electronic Regulator For Speed Control And All Remaining Accessories I/C Safety Pin, Nut Bolts , Washer, Temperature Rise=75 Degree C(Max. ), Insulation Resistance More Than 2Mega Ohm, Suitable For 230V, 50 Hz Ac Supply, Earthing Etc. Complete As Required. , Supplying, Installation Of Exhaust Fan Sweep Not Less Than 300 Mm In The Existing Opening, And Made Of Aluminium Die-Cast Motor Body, Front Protection Guard, Low Noise Operation, Robust Metal Body,Double Ball Bearing,Anti Dust,High Speed(Minimum 1350 Rpm) & High Air Delivery(Minimum 1000 Cmh) Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. , Supplying,Installation, Testing And Commissioning Of Surface Mounted Square/Round Shape Led Downlighter Having Suitable Housing Lumen Efficacy = 100Lm/Watt, System Lumen Output = 1200 Lm, Cri = 80, Power Factor = 0.9 Having Suitable Diffuser And Cct In Between 4000K To 6500 K (I/C Both Limits) Complete With All Accessories Etc. Directly On Ceiling/Wall Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , Sub Head-Iv (Service Connection) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Above 35 Sq. Mm And Upto 95 Sq. Mm , Supplying Of One Number Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade With Isi Marked (Is 7098 (Part - I) / 1988 With Amendment Up To Date) Following Sizes. A) 3 ½ X 35 Sq.Mm , B) 3 ½ X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. A) 3.5 X 35 Sqmm ( 32 Mm ) , B) 3½ X 95 Sq. Mm (45Mm) , Supplying And Fixing Of Light Class G.I. Pipe Of 80 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Sub-Head -V( Lighting Conductor And Earthing ) Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required , Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Sub Head-Vii (Air Condition) Supplying, Installation, Testing And Commissioning Of Suitable Tr Capacity 5 Star Rating With Eer Not Less Than 4.3 , Split Type Inverter Air Conditioning Units Suitable For Indoor Unit To Be Fixed On The Wall Having Minimum Cooling Capacity 5400 Kcal/Hr Suitable For Single Phase Ac Supply Complete With Outdoor Unit Having Copper Condenser Coil,Suitable Clamp/Bracket For Fixing Outdoor Unit, Inter Connection With Suitable Copper Pipe Etc. Complete As Required. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supply, Installation Testing & Commissioning Of Rigid Upvc Piping Complete With Fittings, Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation. A) 25 Mm Dia ( With 6 Mm Nitrile Rubber Insulation) , Construction Of Inspection Banglow, Guest House (For Sanitary & Water Supply) Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe 40 Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Toilet Paper Holder : Vitreous China , Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 , Cutting Chases In Brick Masonry Walls For Following Diameter Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Making Good The Same With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 12.5 Mm Nominal Size), Including Necessary Plaster And Pointing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) : 100 Mm Dia , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms , Providing And Fixing Brass Bib Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 15 Mm Dia Nominal Outer Dia Pipes , 20 Mm Dia Nominal Outer Dia Pipes , 25 Mm Dia Nominal Outer Dia Pipes , 32 Mm Dia Nominal Outer Dia Pipes , 40 Mm Dia Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. Internal Work - Exposed On Wall 20 Mm Dia Nominal Bore , 32 Mm Dia Nominal Bore Metre , 40 Mm Dia Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 20 To 40 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Nominal Bore , 32 Mm Nominal Bore , 40 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 40 Mm Nominal Bore Horizontal , Vertical , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Tube Well Boring With 100 Mm Diameter Casing Pipe For Hand Pump / Tubewell, In All Soils Except Ordinary Hard Rocks Requiring Blasting, Including Removing The Casing Pipe After The Hand Pump / Tube Well Is Lowered And Tested : Up To 6 Metres Depth , Beyond 6 M And Up To 12 M Depth , Beyond 12 M And Up To Required Depth , Providing And Placing In Position Filters Of 40 Mm Diameter G.I. Pipe With Brass Strainer Of Approved Quality. , Providing And Placing In Position Hand Pump Of Approved Quality For 40 Mm Diameter G.I. Pipe Complete With All Accessories. , Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 50 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 150 X 100 Mm Size P Type With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Reducing Socket, Bend, Tee, Etc. , Construction Of Septic Tank. (50 Users) Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement. , Retaining Wall Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Dismentling Existing A-Type Building Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : Of Sectional Area 40 Square Centimetres And Above , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Boundary Wall With Fencing). Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Columns, Pillars, Piers, Abutments, Posts And Struts , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. , Fencing With Reinforced Cement Concrete Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post (Cost Of Reinforced Cement Concrete Posts, Struts, Earth Work And Concrete To Be Paid For Separately) :- Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. , Land Development Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , O.H. Tank Not Found!!! , Solar Street Light Godox S60 Led Focusing Light, Outdoor & Indoor , Gate Pillarlight For Home Outdoor Garden Post Decorative Lamp , Dg Set , Audio Visual Systems Projector (Sony) , Motorised Screen And Accessories (6Ft / 8 Ft) , Digital Podium All-In-One System , Chairman Unit , Delegate Unit , Amplifier 80 Watt , Microphones , Ceiling Mount Speaker ( 6 Watt) , Wire & Lane Cabling For Speaker , Projector & Amplifier Hdmi Wire Connector Wiring Set , Installation, Testing And Commissioning Charges And Configuration Of The System , M.I. 64 -T.V. 4 Nos. @ Rs. 75000/- Per Nos. , Cctv With Motion Sensor And Sound Recorder Including Supplying & Fitting Fixing (Philips Hsp 3800) , Furniture & Fixture Sofa Set A/ Waiting Hall , B/ Executive Guest Room , C/ Suite Room , Executive Table A/ Executive Guest Room , B/ Suite Room , Executive Chair , Bed A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Matress A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Chair A/ Guest Room , B/ Staff Room , C/ Suite Room I)Type-I , Ii)Type-Ii , D/ Security Room , Bed Sheet A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Pillow A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Blanket A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Mosquito Net A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Bath Towel , Hand Towel , Kitchen Utensil A/ Gas Stove , B/ Pressure Cooker , B/ Cookware Set , C/ Dinner Set , D/ Cup Plate Set , E/ Cutlery Set , F/ Mixture Grinder , G/ Electric Kattle , H/ Microwave Oven , I/ Container , Conference Table , Conference Chair (Elentra-112 Steel Frame Fixed Chair)
Contract Date: Jun 16, 2026 Contract Value : 4.10 Crore
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
Madhya Pradesh View Result →
Contract Date: Jun 30, 2026 Contract Value : 34.56 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
14.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
16.
Public Administrative Department #11276744 Technical Bid
Tender for Labour Engaged For Desilting,Readjustment Of Manholes Covers, Diverting The Direction Of Water Dewatering During The Execution Of Work And Disposal Away From Site. , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Meters Lead For Thickness Of Tiles Above 25 Mm And Upto 40 Mm. , Dismantling Dressed Stone Work Ashlar Face Stone Work, Marble Work Or Precast Concrete Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge , Dismantling Roofing Including Ridges, Hips Valleys And Gutters Etc., And Stacking The Material Within 50 Meters Lead. , Dismantling Of Flexible Pavement (Bituminous Courses) By Mechanical Means And Disposal Of Dismantled Material Upto A Lead Of 1 Kilometer, As Per Direction Of Engineer-In-Charge. , Dismantling Manually/ Mechanically Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: Bituminous Road. , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge:1:4:8 Or Leaner Mix (I/C Equivalent Design Mix) , Demolishing Lime Concrete Manually/By Mechanical Means And Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing Brick Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge:In Cement Mortar , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge: 15.2.1 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Reinforced Cement Concrete Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing R.B Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: All Kinds Of Soil : , Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil : , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As10 Sqm On Plan Including Disposal Of Excavated Earth, Leadupto50meterand Lift Upto 1.5M, As Directed By Engineer-In-Charge.All Kinds Of Soil : , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres:All Kinds Of Soil : , Removal Of Excavated Mulba Dismantled Or Unserviceable Material From The Site Of Work By Mechanical Transport Or Animal Transport Or Otherwise Including Loading/Unloading(Complete Job) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.8 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts,Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etcupto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With.1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately.All Works Upto Plinth Level , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately. All Works Above Plinth Level Upto Floor V Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For: Foundations, Footings, Bases For Columns , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs Andsteps Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Edges Of Slabs And Breaks In Floors And Walls , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platforms. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Arches, Domes, Vaults Upto 6 M Span , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level With Cold Twisted Bar , Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. , Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded , Providing And Laying River Bed Material On The Road Surface By Way Of Spreading The Same In Uniform Layer Not Exceeding 20Cm In Depth, Watering And Compacting With Vibratory Power Road Roller Of 8-10 Tonne Capacity Incl Carriage Of Material From Source To Site Of Work (All Leads , Lifts Complete).The Measurement Is To Be Taken Of Compacted / Finished Work. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. , Providing And Fixing 60Mm Interlocked Paver Tile Over A Layer Of Cement Mortar 1:4 Mix Incl Filling Of Joints With Cement Mortar 1:3 (Complete Job) , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete All As Per Direction Of Engineer-In-Charge. 80 Mm Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. , 12Mm Cement Plaster Of Mix: 1 : 6 ( 1 Cement : 6 Fine Sand) , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand) , Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand) , Extra For Brick Work With Common Burnt Clay Bricks/Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level , Tile Brick Masonry With Common Burnt Clay Tile Bricks Of Class Designation 10 In Foundation And Plinth Including Curing Complete In: Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Fine Sand) , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equipped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specifications And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Ofgrade Vg-30 @ 3.5% (Percentage By Weight Of Total Mix) Prepared In Drum Type Hot Mix Plant Of 60-90 Tph Capacity , Supplying,Stacking, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Bound Macadam (Wbm-Iii) With Graded Crushed Stone Aggregate Of Size 53Mm To 22.4 Mm In Uniform Thickness,Hand Picking , Rolling With Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber,Applying And Brooming Requisite Type Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate,Watering And Compacting To The Required Density.Complete Job , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications. On Bitumen Surface @ 0.50 Kg/Sqm. , Hand-Packing Stones In Wire-Crates; Excluding Cost Of Crates And Stones , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications.16.38.1 On W.B.M. @ 0.75 Kg/Sqm. , Providing And Laying Seal Coat Of Premixed Fine Aggregate (Passing 2.36 Mm And Retained On 180 Micron Sieve) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg-30 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface Including Rolling And Finishing With Road All Complete , 2.5 Cm Premix Carpet Surfacing With 2.25Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Including A Tack Coat With Hot Straight Run Bitumen Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete (Tack Coat To Be Paid For Separately). Vwith Paving Asphalt Grade Vg-30 With No Solvent , 10Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa At 35Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Specified Tile Bricks Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finishing Neat. 12.25.1 With Common Burnt Clay (Non Modular) Brick Tiles Of Class Designation 10.0 , Providing And Fixing Precoated Galvanized Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : 12.24.1 Ridges Plain (500 - 600Mm) 12.24.2 Flashings/ Aprons.(Upto 600 , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6mm Angle Iron And 3Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer. Using Flats 30X6mm For Diagonal Braces And Central Cross Piece. , Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 2 Mm Thick , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade On New Work (Two Or More Coats Applied @ 1.67 Liter/10Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10Sqm) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Chequerred Precast Cement Concrete Tiles 22Mm Thick In Footpath And Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing, Cleaning And Curing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) . Dark Shade Using Ordinary Cement. , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. , Pvc Bend , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. (I) Single Socketed Pipes 75 Mm Diametre , Providing And Fixing Of Pvc Including All Fitting With Complete Job , Providing And Fixing Of Towal Ring With All Fitting With Complete Job , Providing And Inserting Upvc Pipe ( Working Pressure4kg/ Cm2) Single Sockted Pipe 110 Mm Dia , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc.: Internal Work-Exposed On Wall 15 Mm Dia. Nominal Bore , Dumping Of Stone Including Cost Of Stone Filling, Including Supply Of Stone And Carriage Complete Job , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Supply Of Wire Crates Of Approved Mesh Including Weaving Binding Sides And Partitionsand Binding Top After Filling Complete Job. , Extra For Every Additional Lift Of 1.5 M Or Part There Of Beyond 1.5 M Height For Hand-Packing Of Stones In Wire-Crates , Providing And Fixing Of Weep Hole With Pvc Pipe Of 100 Mm Dia Complete Job , Providing And Fixing Of Weep Hole With Pvc Pipe Of 110 Mm Dia Complete Job , Stone Work In Super Structure Upto Floor Five Level In Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand) Including Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: White Sand Stone , Stone Work Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand) Including Centering, Shuttering And Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: Red Sand Stone B White Sand Stone , Plastering With Lime Surkhi Mortar Of 20Mm Thickness Including Preparation Of Mortar, Tamping, Curing, Prepared By Traditional Methods Including Mixing Of Gur, Tamarind Water, Dal Etc. As Per Tradition, The Work Is To Be Done With All Leads And Lifts, Surfaces To Be Plastered Shall Be Thoroughly Cleaned Of All Dust, Grease, Oil Etc. All Surfaces Should Be Kept Damp During The Progress Of Work. The Engineer-In-Charge Will Inspect And Approve All Preparatory Work. Curing To Be Done For 21 Days By Means Of Spraying , Roviding And Applying Lime Kara 1:2 (1 Lime: 2 Zikki Powder) Grinding Mortar With Grinding Mill/Manually On Lime Base, On All Flat Surface In Two Coats. First Coat Applying 3 To 4 M Thick And Curing Properly At Least 7 Days, Second Finishing Coat Done After 7 Days Of Previous Coat As Per Tradtional Practice (Thickness Not More Than 6Mm). , Providing Protective Coating Of Water Repellent Siloxane (Transparent In Color) Through Brush Or Spray Until Complete Impregnation Over Completely Cleaned And Dried Stone Or Plastered Surface To Reduce The Absorption Of Water , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Meter Lead As Per Direction Of Engineer-In-Charge. , Providing And Fixing Steel (White Powder Coated) Crescent Lock For Upvc Sliding Window/ Door With Necessary Screws Etc. Complete , Providing And Fixing Of Steel Banches , Providing And Fixing Glass Panes With Putty And Glazing Clips In Steel Door/ Windows/ Clerestory Window All Complete With 5.00Mm Thick Glass Panes Complete Job , Providing And Fixing Of Soap Dish , Providing And Fixing Inaugration Plate Including Writing Etc. Complete Job. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Sand For An Avg Distance Of 5 Kms , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Stone Aggrigate For An Average Distance Of 7 Kms By Mt. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Brick For An Avg Distance Of 5 Kms , Electrification Items : Supply, Installation, Testing & Commissioning Of 5 Mtr Height Decorative Pole Made Of Galavnised Mild Steel Pipe Duly Polyurethane (Pu) Paint Coated With 1 Mtr. Long Double Arm Designer Bracket Is Made Of Round Tube Conforming To Is 1161. The Pole(Od Of 114.3Mm And Thickness-3.6Mm) With Bracket Is Given Pre-Treatment And Finished With Pu Paint Giving It A Pleasing Appearance And Antique Finish. Pole Shall Be Available To Hot Dip Galvanize The Tube Before Painting. Foundation Bolt Size Shall Be 20X600x4nos. With Base Plate Size 300X300x12mm. A Door Is Provided With Electrical Accessories (Connector, Bakelite Sheet And 6 annual periodical maintenance Single Pole Mcb, Cable Looping Termional For 4X4/6Sqmm Copper Cable). Aluminium Casting In Golden Ring Form At Bottom, Middle, Top Of The Pole. The Pole Will Be Supplied With Brackets And Luminaire Combinations To Suit The Requirement. Branding Name Shall Be Embossed At The Bottom Near Junction/Mcb Box. Sticker Not Allowed In The Form Of Company Branding. Pole Shall Be Supplied With Outdoor Post Top Luminaire Of 45 Watt Ip67 Mounted In Suspension Type Having An Approximate Size Of 460Mm Outer Diameter And 635Mm Height, Housing - Aluminium With Designer Steel Aesthetic Crown, Optical Grade Opal Injection Moulded/Clear Polycarbonate Diffuser And Graphite Grey Uv Resistant Colour,Constant Current Electronic, Driver Provided With High Voltage ,Open & Short Circuit Protection And Ambient Temperature -10C To +40C. Supply 150V- 240V Power Factor 0.95 ,Thd ≤ 20% Internal Surge Protection Of 4Kv With Following Specification Of Light Engine For 45W : 4500Lumens, Cct 3000K ±500 Cct ,Cri 70 And Lumen Maintenance Of L70 At 50000 Hours Ip 65 Connectors,Accessories Etc Complete With All Repects. Design Of Pole Should Be Such That It Should Maintains Proper Illumination On Both Side.(Analysis Attached) , Led Flood Light, Powder Coated Pressure Die Cast Aluminium (System Lumen Efficacy ≥105 120 Lm/Watt). Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr -15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofrelevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 120 Lm/Watt Output .Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-Incharge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 250 Watt , Led Linear Profile (Ac) Led Rgb/Rgbww/ Rgbnw/Rgba/Rgbw, Linear Profile / Wall Washer Luminaire For Façade Lighting With Aluminium Extruded/ Die Cast Housing With Inbuilt Driver Of Following Wattage. Wattage Per Meter 25W , Supply, Installation, Testing & Commissioning Of 1.1 Grade, 4Cx10 Sqmm Al. Armoured Xlpe Sheathed Cable Including Termination (Along With Lugs) , Providing And Fixing Of Gi Pipe 50 Mm Dia , Feeder Pillar 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accessories 4 Way Distribution Service Pillar. Support Galvanised Angle Frame And Legs (40Mm X 40 Mm X 3Mm) For Distribution Feeder Pillar With Leg Height 1M With 0.3M In Soil Approx [email protected] Per Mtr, Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip.Cement Grouting For Support Angle Legs, Spares @ 3%, Erection Charges @10%, Overheads @ 5% (1.0% T&P 0.5% Storage And Handling , 3% Contingency And Safety Equipments, 0.5% Insurance) And Turnkey Factor @25% With Astronomical Timer. , Earthing With Copper Earth Plate 600Mm * 600Mm * 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required. , Wiring For Light Point/Fans Point/Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insıslated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gf Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group-A , Add For Vetting Charges Consultency And Contigencies @ 2.5 %
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Jammu And Kashmir View Result →
19.
Tourism #11266721 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 11
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
22.
Housing Urban and Rular Development #11229363 AOC
Misc. Repairs And Other Civil Works Of Tiles, Doors, Windows,Wooden Flooring, Shed And Internal And External Painting In C.M. Bunglow Civil Line Nagpur.(Only For Society).-= 1 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand 2 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 3 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. 4 Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 1190 to 1202 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring 5 Providing and laying Vitrified MATT finishhaving decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical andconfirmingtoIS15622-2006(GroupBla)ofapprovedmakeshadeandpatternfor flooringinrequiredpositionlaidonabedofbondingchemicalfillingjointscuringand cleaning etc .complete. 6 Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. 7 Providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 8 Providing and fixingTable top white wash basin of size 120x635x405mm rubber plugs and brass chain, withpillar cock, C.P.Angular stop cock long thread, continentalincluding S.S. bottle trap of approved make havingnecessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. 9 ProvidingandapplyingTextureplasterwithfinishingwithtexturematerial ofapproved makein 3 to 4 millimeterthickness on previously plastered surface, including Plaster Groove 6mmthicknessorTapeGrooves35to45mmthicknessorasrequired,inallposition including preparing the surface, scaffolding etc. complete. 10 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box 11 Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand. 12 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm 13 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 14 Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etccomplete 15 Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete.b) Granite 16 Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. 17 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. 18 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc.as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.Spec. No. : As directed by Engineer-in-charge. 19 Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors/windows including providing and fixing clips, putty etc. complete. (a) 2.00 mm thick. 20 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. 21 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. 22 Removing W.C. Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the service-able materials as and where directed includingthrowing the unserviceable materials out side etc. complete. 23 Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 24 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. 25 Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. 26 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 27 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 28 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 29 Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 30 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 31 Providing and fixing C.P. BIB cock with wall flange jaquar or equivalent make continental (CAT.NO. CON-047) including necessary sockets/ union nut etc. complete. 32 Providing and fixing C.P. Angular stop clock with wall flange Jaquar make or equivalentcontinental (CAT.NO. CON-059) including necessary sockets/union nut etc. complete. 33 Providing and fixing C.P. pillar cock long neck with aerator jaquar or equivalent make continental (CAT.NO. CON -021) including necessary sockets/union nut etc. complete. 34 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 35 Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 36 Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. 37 Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets & necessary fittings and tested as per municipal requirement etc. complete. 38 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres 39 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 40 Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover. 41 Providing & constructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover etc. complete. 42 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange jaquar or equivalent ?make continental (CAT.NO. CON-273 UPR) including necessary sockets/union nut etc. complete. 43 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 44 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. 45 Providing and fixing crimped with G.I. mesh and size 20 mm x 20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel) 46 Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. 5 km leadloading unloading 47 Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. 48 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 kg) 49 Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 kg) 50 Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kg/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaningetc. complete. (using 100% crushed sand) 51 Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards,screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. 52 Providing and fixing Shutter to wall Cupboard consisting of Teak Wood styles and Rails 25 mm thick and 75 mm wide with panel insert of 12 mm thick particle Board with one approved coloured Laminated Face on one side 1.5 mm thick, bonded with Phenol Formaldehyde Synthetic Resin including Lipping Beading. Iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame). 53 Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 90 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete.(excluding painting to underside of plank). 54 Providing and fixing C.P. 2 Way BIB cock with wall flange of approvedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge. 55 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) 56 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete 57 Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. 58 Trimming of grass, shurbs and weeds from the shoulders/berms and disposing off the same to suitable locations etc. complete 59 Replacement of damaged Mortise Lock of approved quality and make to door shutter including Removing and Refixing with Necessaryscrew, making proper adjustment for smoothoperation etc. complete as per sample approved by Engineer in-chareg. 60 ProvidingHydrulic door closer .... 61 ProvidingSuper Jet Spry with flange 2 in 1 faucet 1.50 mtr long. 62 Providing Skilled plumber with tools as per direction of Engineer Incharge. 63 Providing skilled carpentor with tools as per direction of Engineer Incharge 64 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface and including scraping etc. complete. 65 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 66 Providing and applying single coats ofexterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. 67 Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete 68 Providing and fixing high level 10 liter capacity with fittings inlet PVC pipe with stop tap ,brackets for fixing the cistern,32 mm dia. PVC flush pipe with fitting and clamps 20 mm dia. PVC overflow pipe with mosquito proof couplings, galvanised iron chain and pulley painting if ordered to cistern pipe etc. and cutting and making good the damaged wall and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) 69 Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. 70 Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete 71 Providing curtain rod dropping with channel MAC brand of superiar quaility including all required material labour etc complete. as directed by engineer incharge......... 72 Replacement of damaged alluminium Butt Hinges of 125 mm of approved quality and maketo door shutter including removing existing the same inoriginal position making prope radjustment for smooth operation etc. complete as per sample approved by Engineer incharge. 73 Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and maketo door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. 74 Replacement of damaged Tower Bolt 300 mm Chromium plated of approved quality and maketo door/window shutter including removing existing the same inoriginal position making proper adjustment for smooth operationetc.complete as per sample approved by Engineer in-charge. 75 ProvidingHandle 150 mm Chromium plated (Rounded shape). 76 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. 77 Providing and injecting epoxy grout including structuring of crack in the body of slab girder by sand blasting, fixing inlet tube arrangement including cost of materials, machinery required for the work and labour charges etc. complete. 78 Providing & fixing Decorative wall paper superior quality including adhesive to fix at wall etc complete. as directed by engineer incharge......... 79 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 80 Providing & fixing Mica laminate as per ISI 0.1 mm thick etc complete...... 81 Providing & fixing 19 mm plywood 710 bwp full red core with report etc complete...... 82 Providing & fixing 12 mm plywood 710 bwp full red core with report etc complete...... 83 Providing & fixing teak wood batterns 50x25 mm etc complete...... 84 Providing & fixing plain glass 6 mmetc complete...... 85 Providing & fixing teak wood batterns 70x45 mm etc complete...... 86 Providing & fixing door stopper etc complete...... 87 Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete. 88 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 89 Providing and Laying wearing laminate wooden or eqiuvalent flooring 8 mm thick in attractive strips for conference hall. 90 Providing, laying andfixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 kg/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 91 Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. 92 Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with allnecessaryfixturesandfittingetc.complete.(SampletobefinalbyEngineerIn-charge prior execution of work) 93 Providing and applying French polish for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding etc. complete as directed 94 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. 95 Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 96 Providing and fixing C.P. sink cock with raised J shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete. 97 Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. 98 Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. 99 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 100 BASIC TEST OF CEMENT :-Standerd Consistancy Fineness, Specific Graviti, Setting Time (Initial & final, Compressive Strength, Soundness. 101 BASIC TEST OF BRICK :-Water Absorption, (Set of 5 Brick), Comoressive Strength (Set of 5 Blocks), Efflorescence (Set of 5 Bricks) 102 CERAMIC TILES/ VITRIFIED TILES :- Water Absorption, Modules of Rapture (Set of 6 Tiles) 103 BASIC TEST OF C. C. TILES. :-Flexural test(Set of 6 tiles) Water Absorption,(Set of 6 tiles) Resistance to wear(Set of 6 tiles). 104 BASIC TEST OF Fine Aggregate Fineness Modulus (Sieve Analysis) silt and cley content..... 105 BASIC TEST OF Concrete Paving Block :- Compressive strength, Water Absorption, (Set of 8 Blocks ) 106 BASIC TEST OF STONE / RUBBLE/ Crushing Value/Compressive strengh, Water 107 Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction materials for whichroyalty is necessary.(Royalty charges will be paid to contractor after sumbitting valid documents of revenue authority)Royalty for naturalSand (Royalty + Surcharges 2% & Distt. mineral foundation cess 10%)
Contract Date: Jun 04, 2026 Contract Value : 15.18 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
23.
Public Administrative Department #11199742 AOC
Carrying Out Civil Maintenance Work For The Phase 1,2,3,4 At Ravet Pumping Station.-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for thefoundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Excavation for foundation in earth, soils of all types, sand ,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed forthe foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means Providing general pest control services to the building to control the nuisance of cockroaches, lizards, pin bores and other insects etc. with 4 operations in a year and monthly check up. Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete. Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. Ground Floor Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs anddrawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. Providing Gas or Electrical welding for structural steel section, plates as per detailed drawing. For less than 10 mm thick section. Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.(Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Lift 0.0 to 3.8 M Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, f oundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No.: Bd.F.17, Page No. 306 Ground Floor Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc .complete. Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Lift 0.0 to 3.8 M Providing Second class fly ash brick masonry with conventional / I.S. type bricks cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete. Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Gound Floor Removing the tar or coba and disposing of the material as directed etc. complete. Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, after application TP- 42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee-LM @ 700 gms/ One Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/ One Square Metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplast fibre @ 125 gms/ One Square Metre to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. Providing and Applying DuraClean- WR for cleaning the TMT bars, steel structure etc. of structure by Waterjet cleaning/ grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal surface also removing loose particles(using other mechanical / manual means) and apply on prepared surface of DuraGuard - as corrosion preventive coat on prepared TMT bars, steel structure,metal surface etc. to protect it from corrosion etc. as per manufacturers specification ( using other manual / mechinical means) complete as per specification including cost of all materials, machinery, labour, insurance charges as directed by the Engineer in charge. Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor Lift 0.0 to 3.8 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of to 15 mm thick in C.M. 1:4 rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Providing flush grooved pointing with cement mortar 1:3 for brick work including scaffolding and curing etc. complete. Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. line and level including neat finishing scaffolding curing etc. complete. Providing and laying Polished Tandur Stone flooring 25mm to 30mm thick required width in plain/ diamond pattern on bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Providing sills of polished Kadappa stone 25mm to 30mm thick, on a bed of 1:4 cement mortar including cement float, filling joints with slurry, curing polishing and cleaning etc. complete. Providing and fixing heavy duty inter locking concrete Grey paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in requiredposition laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Ground Floor Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Ground Floor Removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. complete. Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning preparing the plaster surface applying primer coat scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary Scrapping the old plastered internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding etc. complete as directed. Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. excluding the primer coat.) etc. complete. Lift 0.0 to 3.8 M Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 mm x 40 mm weighing 0.39 Kilogram/m. at 60 cms c/c and fixed with ( 15 x 15 mm) flanges weighing 0.119 Kilogram/m suspended on 6 mm dia. mild steel rod weighing 0.22 Kilogram/m fixed on wall and beams including rounding of the edges with aluminium T of 50 mm x 40 mm weighing 0.39 Kilogram/m etc. including all labour etc. complete. Providing and fixing false ceiling of 15mm thick as per drawings including powder coated G.I. wall angle of 20 mm x 20 mm x 0.60 mm size, G.I. grid runners of size 15 mm x 38 mm at 600 mm center to center both ways and suspended using G.I. 3 mm wire including fixing using butterfly clips and fasteners including transporting, scaffolding all necessary labour and machinery, finishing etc. complete. Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 Kilogram/sq.m.). Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Providing and fixing factory made panelled door shutter in single leaf 35 mm thick style and rail without ventilator with CCTW panels 12 mm thick including wrought iron hold fast and stainless steel fixtures with oil painting 3 coats etc. complete. Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One RunningMetre. Inter locking section 40 x 18 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass withall required screws and nuts etc, complete. With colour Anodising with box. etc
Contract Date: Jun 01, 2026 Contract Value : 44.74 Lakh
Local Bodies No of Bidders 4
Maharashtra View Result →
24.
Defence #11191786 Price Bid
Tender for Dismantling Plain Or Corrugated Steel Sheeting Any Guage, Thickness, Including Nainital Pattern Or Similar Pattern Roof Covering Complete All As Specified And Directed. , Demolition Of Brick Work Or Stone Masonry Precast Plain Cement Concrete Block Walling Built In Cement Mortar Complete All As Specified And Directed. , Taking Down Cement Or Cement Lime Plaster Of Any Description On Brick Or Plain Cement Concrete Blocks Or Stone Wall Or Concrete Surface Etc Including Racking Out Joints, Hacking For Keys, Scrubbing Down With Water Etc All As Specified And Directed. , Dismantling Of Wall/ Ceiling Board (Flbre Pulp, Insulation Etc) Or Insulation Boards/ Slabs / Blankets Any Thickness, Including Cover Fillets Complete All As Specified And Directed. , Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And Directed. , Dismantling Timber Scantlings 40 Sq. Cm And Over In Section, In Any Position Complete All As Specified , Taking Up Or Down 15Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Taking Up Or Down 20Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Dismantling Water Tanks 500 Ltrs Capacity Complete All As Specified And Directed. , Dismantling Water Tanks Of Any Description, Capacity Exceeding 500 Litres But Not Exceeding1000 Liters Complete. , S&F In Repairs Of Galvanised Mild Steel Wire Cloth 0.45 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.18Mm And Fixed With Tinned Tacks Or Galvanised Wire Staples Complete All As Specified And Directed. , Hacking Out Old Broken Glass (Any Thickness, Size, Quality Or Description) From Wooden/Metal Frames, Glazed With Putty Or Fixed With Beads Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones All As Specified , S&F 4 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa (Az 150) As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F 0.63Mm Thick Galvanised Corrugated Ms Sheeting (Cgi Sheet Roofing) With Two Corrugation Side Laps, With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusive Fixed With Coach Screws And Washers As In Roofs Etc All As Specified , S&F 0.63Mm Thick Plain Galvanised Ms Sheeting Using Grade-O Sheets With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusives, As In Roof, Ridges, Hips, Valley Gutters, Drip And Straight Flashing Complete All As Specified And Directed. , M&L For Brick Work With Sub Class B Bricks Using Old Size Bricks Straight Or Curved On Plan Exc 6 Mtr Mean Radius, Built In Cm 1:6 All As Specified And Directed. , M&L For Rendering 15 Mm Thick Readymade Plaster On Inner/Outer Walls By Adding 17-19% Of Potable Water By Weight Of Material For Thickness Above 15Mm It Is Recommended To Be Applied In Multiple Layers. Ready Mix Plaster Shall Complies With Is 1661-1972, Is 2250-1965, Is 2402-1963 And Confirms The Compressive Strength @ 28 Days 10-12 Mpa/Bulk Density 1500-1600 Kg/M3. (Note : The Rate Quoted By Contractor Shall Include Cleaning Of Surface, Application As Per Instruction And Scaffolding Upto 20 Mtr Ht All As Specified And Directed.Make Fosroc/ Sika/ Ultrarech/ Choksey , M&L For Preparation Of New Plastered Surfaces & Applying A Layer Of Birla Putty On Wall Surfaces Including Cornics Etc For Proper Levelling Of Plaster And Two Coat Of Oil Emulision Distemper Complete All As Specified And Directed. , M/L For Complete Removal Of Existing Treatment For Preparing Old Painted Surfacess And Applying Two Coat Of Distemper Oil Emulsion Over A Coat Of Primer Complete All As Specified And Directed. , M&L Three Coats Of White Wash On Ceiling Including All Preparation Complete All As Sopecified , Material & Labour For Applying Two Or More Coats Of 100% Remium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance,Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives@ 1.43 Litre/ 10 Sqm Over And Including Primingcoat Of Exterior Primer Applied @ 0.90 Litre/ 10Sqm Over New Surfaces Complete All As Specified And Directed. , M&L Preparation Of Old Surfaces Including Cornices Etc And One Coat Of Oil Bound Distemper Complete All As Specified And Directed. , S&F 20Mm Thick 2Nd Class Soft Wood (Chir) Boarding Planned One Side Fixed With Butt Joints With Nails In Any Situation/Position Except Flooring And Skirting Complete All As Specified And Directed. , M&L For 2Nd Class Hard Wood Clean Sawn In As In Scantling Framed And Over 40Sqcm Fixed With Screws Etc All As Specified And Directed.. , S & F Second Class Hardwood 25 Mm Boarding Plain One Side With Butt Joint Fixed With Nails In Any Situation. Complete All As Specified And Directed. , S&F Of Powder Coated Grid Frame Work For False Celling Comprising Of The Following Sections For Making Partitions Of 605X605 Mm Size Fixed To Walls With Rawl Plugs & Screws And Hanged To Roof With And Including 4Mm Dia Gi Wire Suspender Of Suitable Length And Butterfly Clips, Size Of Main Tee Shall Be 28Mmx24mmx0.3Mm Thick , Cross Tee Shall Be 28Mmx24mmx0.3Mm Thick And Wall Angle Shall Be 24Mmx24mmx0.3 Mm Thick Incl 4 Mm Thick E-Board Classic (Make-Everest) For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Snap Grid As In Ceiling With And Including Dusting Of Surface Complete All As Specified And Directed.Complete All As Specified And Directed. , S&F Solid Pvc Wall Lining Dual Colour Consisting Of 5 Mm Thick Wood Grain Printed Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame As Per Specification And Drawing Complete Fixing Arrangement Including Taking Down Old Existing Wooden Panelling Complete. , S & F 5Mm Thick Pvc Sheet Fillet Of Width 35Mm For Wall Paneling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specification And Drawing. , S&F In Repair 110Mm Dia Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Joints Fixed To Walls Or Laid In Trenches Etc Complete. , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 500 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Complete All As Specified And Directed. , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 1000 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Complete All As Specified And Directed. , S & F 20Mm Dia Aluminium Alloy Anodised Curtain Rod Decorative Fency Type With Brackets Complete All As Specified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttarakhand View Result →
25.
Defence #11191783 Price Bid
Tender for Dismantling Plain Or Corrugated Steel Sheeting Any Guage, Thickness, Including Nainital Pattern Or Similar Pattern Roof Covering Complete All As Specified And Directed. , Demolition Of Brick Work Or Stone Masonry Precast Plain Cement Concrete Block Walling Built In Cement Mortar Complete All As Specified And Directed. , Taking Down Cement Or Cement Lime Plaster Of Any Description On Brick Or Plain Cement Concrete Blocks Or Stone Wall Or Concrete Surface Etc Including Racking Out Joints, Hacking For Keys, Scrubbing Down With Water Etc All As Specified And Directed. , Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And Directed. , Dismantling Timber Scantlings 40 Sq. Cm And Over In Section, In Any Position Complete All As Specified , Taking Up Or Down 15Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Taking Up Or Down 20Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Dismantling Water Tanks 500 Ltrs Capacity Complete All As Specified And Directed. , Dismantling Water Tanks Of Any Description, Capacity Exceeding 500 Litres But Not Exceeding1000 Liters Complete. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Not Exc 1.5 Sqm Each.& Removing To Or From Store All As Specifed & Directed. , Taking Down Chowkats Or Frames Exc 1.5 Sqm But Not Exc 4 Sqm Each With Shutters (Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing) Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. , Dismantling Of Ceiling Board (Flbre Pulp, Insulation Etc) Or Insulation Boards/Slabs/Blankets Any Thickness, Including Cover Fillets Complete All As Specified And Directed. , S&F In Repairs Of Galvanised Mild Steel Wire Cloth 0.45 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.18Mm And Fixed With Tinned Tacks Or Galvanised Wire Staples Complete All As Specified And Directed. , Hacking Out Old Broken Glass (Any Thickness, Size, Quality Or Description) From Wooden/Metal Frames, Glazed With Putty Or Fixed With Beads Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones All As Specified , S&F 4 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa (Az 150) As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F 0.63Mm Thick Galvanised Corrugated Ms Sheeting (Cgi Sheet Roofing) With Two Corrugation Side Laps, With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusive Fixed With Coach Screws And Washers As In Roofs Etc All As Specified , S&F 0.63Mm Thick Plain Galvanised Ms Sheeting Using Grade-O Sheets With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusives, As In Roof, Ridges, Hips, Valley Gutters, Drip And Straight Flashing Complete All As Specified And Directed. , S&F Of Powder Coated Grid Frame Work For False Celling Comprising Of The Following Sections For Making Partitions Of 600X600 Mm Size Fixed To Walls With Rawl Plugs & Screws And Hanged To Roof With And Including 4Mm Dia Gi Wire Suspender Of Suitable Length And Butterfly Clips, Size Of Main Tee Shall Be 28Mmx24mmx0.3Mm Thick , Cross Tee Shall Be 28Mmx24mmx0.3Mm Thick And Wall Angle Shall Be 24Mmx24mmx0.3 Mm Thick Incl 4 Mm Thick E-Board Classic (Make-Everest) For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Snap Grid As In Ceiling With And Including Dusting Of Surface Complete All As Specified And Directed.Complete All As Specified And Directed. , M&L For Brick Work With Sub Class B Bricks Using Old Size Bricks Straight Or Curved On Plan Exc 6 Mtr Mean Radius, Built In Cm 1:6 All As Specified And Directed. , M&L For Rendering 15 Mm Thick Readymade Plaster On Inner/Outer Walls By Adding 17-19% Of Potable Water By Weight Of Material For Thickness Above 15Mm It Is Recommended To Be Applied In Multiple Layers. Ready Mix Plaster Shall Complies With Is 1661-1972, Is 2250-1965, Is 2402-1963 And Confirms The Compressive Strength @ 28 Days 10-12 Mpa/Bulk Density 1500-1600 Kg/M3. (Note : The Rate Quoted By Contractor Shall Include Cleaning Of Surface, Application As Per Instruction And Scaffolding Upto 20 Mtr Ht All As Specified And Directed.Make Fosroc/ Sika/ Ultrarech/ Choksey , M&L For Preparation Of New Plastered Surfaces & Applying A Layer Of Birla Putty On Wall Surfaces Including Cornics Etc For Proper Levelling Of Plaster And Two Coat Of Oil Emulision Distemper Complete All As Specified And Directed. , M/L For Complete Removal Of Existing Treatment For Preparing Old Painted Surfacess And Applying Two Coat Of Distemper Oil Emulsion Over A Coat Of Primer Complete All As Specified And Directed. , M&L Three Coats Of White Wash On Ceiling Including All Preparation Complete All As Sopecified , Material & Labour For Applying Two Or More Coats Of 100% Remium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance,Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives@ 1.43 Litre/ 10 Sqm Over And Including Primingcoat Of Exterior Primer Applied @ 0.90 Litre/ 10Sqm Over New Surfaces Complete All As Specified And Directed. , M&L Preparation Of Old Surfaces Including Cornices Etc And One Coat Of Oil Bound Distemper Complete All As Specified And Directed. , S&F 20Mm Thick 2Nd Class Soft Wood (Chir) Boarding Planned One Side Fixed With Butt Joints With Nails In Any Situation/Position Except Flooring And Skirting Complete All As Specified And Directed. , M&L For 2Nd Class Hard Wood Clean Sawn In As In Scantling Framed And Over 40Sqcm Fixed With Screws Etc All As Specified And Directed.. , S&F In Repair 110Mm Dia Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Joints Fixed To Walls Or Laid In Trenches Etc Complete. , S&F In Repair 75Mm Dia Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Joints Fixed To Walls Or Laid In Trenches Etc Complete. , M&L 300X450x7mm Thick Glazed Ceramic Digital Tiles Coloured Incl , Design And Pattern As Approved Fixed As In Vertical Surface Etc, Set And Jointed In Neat Cement Slurry And Pointed With White Cement With Colour Pigment To Match Incl Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 Complete All As Specified And Directed. , M&L Colour Non Skid Ceramic Tiles 7 To 8 Mm Thick ( Square/ Rectangular) Area Of Each Tiles Exc. 0.11 Sqm But N.Exc. 0.18 Sqm In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Cement With Colour Pigment Incl 15Mm Thick Screed Bed In Cm 1:6 Complete All As Spd , M&L For 15Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , M&L For 20 Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , S&F In Repair 15Mm Dia Bib Tap Long Body Cp, Screwed For Iron Pipes Complete All As Specified And Directed , S&F Angle Cock 15 Mm Bore Brass Chromium Plated, Screwed Both Ends For Pipes Or For Unions Fixed In Repairs Including Making Good To Match With Existing Surface , S&F Pillar Taps 15 Mm Bore, Brass Chromium Plated , Screwed Down High Pressure With Or Without Letter Hot Or Cold With Long Screwed Shanks And Fly Nut Complete All As Specified, Fixed In Repairs. , S&F Bib Tap Standard Of Ptmt (Polytetra Methylene Terephthalate Engineering Thermoplastic Bath Fitting), Any Colour, Screwed Foriron Pipe 15 Mm Bore Pipe (Minimum Weight 90 Gm) All As Specified, Fixed In Repairs (Make : Prayag Or Equivelent As Approved) , S&F In Repair Polymer White (Polypropeylene Delrin And Abs) Low Level Flushing Cistern 10 Ltrs Capacity, Valveless, Syphonic Action Type Complete With Inlet, Ball Valve Float Valve, Bends Brackets, Rawl Plug, Brass Screws Handle Etc Complete, Complete All As Specified And Directed. , S&F In Repairs, 550X400mm Vitreous China, Wash Hand Basin , Flat Back With Pedestal Excluding Trap And Waste Chain And Plug And Porcelain Stopper Including Sutaible Size Brackets Waste Pipe And Waste Coupling Complete All As Specified And Directed. , S&F Vitreous China Squatting Pan Orrissa Pattern Size 580 X 440 Mm White With Intregal Foot Rests, With & Including P Or S Trap (Excluding Material & Labour Of Flushing Cistern And Flush Pipe) Including Conection To Trap And To Flush Pipe Etc Complete Including Making Good To Floor Complete All As Specified And Directed Fixed In Repairs. , S& F In Repair Vitreous China Premium/ 1St Quality Wash Down Water Closet Ewc White/ Ivory/Off White (Closed Pattern Incl All Necessary Accessories Like Rag Bolts/ Gel Gasket Etc. (Excluding Flushing Cistern & Flush Pipe) Complete In All Respect All As Specified. , M&L Pvc (Swr) Floor Trap 75Mm Dia Plain With Grating Including Jointing With Solvent Cement Etc Complete, Fixed In Repair. , S&F Pvc Circular Top Cover Suitable To Rotational Moulded Polyethylene Water Storage Tanks Of 300 /500 Litres Capacity Tanks Of Standard Mares, With 6 Mm Dia Nut And Bolts On Two Ends Of Cover To Act As Hinge As Will As Locking Arrangement For Side Opening , M&L For Sunken Floor Treatment As Described As Under (I) To (Vii) :- (I) Demolition Of Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Or In Any Type Of Filling In Sunken Portion & Cleaned The Sunken Portion Incl Vertical Wall Surface Complete As Directed. (Ii) M&L To Fill The Sunken Floor With Plain Cement Concrete ( 1:5:10) Type E-2 Using Bk Aggregate Over The Treated Surface Complete All As Specified And Directed. (Iii) M& L 40Mm Thick (Min) Plain Cement Concrete (1:2:4) Type B-0 Using 12.5 Mm Graded Stone Aggregate With Integral Water Proofing Compound As Per Manufacturer Instructions On Bottom Of Sunken Portion With Proper Slope Towards Spout. Vertical Sides Shall Be Plastered In Cm (1:3) 15 Mm Thick Mixed With Water Proofing Compound As Per Manufacturer Instructions. Plaster Shall Be Extended Over Plain Cement Concrete Coving When The Same Is Green I.E. Plain Cement Concrete & Plaster Be Carried Out At The Same Time Complete All As Specified And Directed.(Iv) After Laying Sewage/ Plumbing Pipes With Fixtures In Position 2 Coats Of Omiplas Ep-101 Epoxy Compound Shall Be Applied Complete All As Specified And Directed.(V) Spouts Of 25Mm Dia Gi Pipe Light Grade Projecting 450Mm Clear Of Face Outer A Wall With Mosquito Proof Cap On Inner Face Of Pipe Shall Be Provided To Drain Out Seepage Water ,Including Cutting Holes And Making Good If Needed As Specified And Directed. (Vi) Test Again Of Water Tightness By Pounding For 72 Hours & Rectify Defects If Any Till Total Elimination Of Defects Complete All As Specified And Directed.The Sunken Portion Shall Be Tested For Leakage / Seepage / Dampness By Pounding With Water For 72 Hours. In Case Any Defect Is Noticed The Portion Shall Be Grouted With Cement Slurry Mixed With Suitable Chemical & Tested Again. The Process Of Grouting And Testing Shall Be Repeated Till Leakage / Seepage / Dampness Is Eliminated. , Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door/ Window/ Ceosetory Window & Other Frames/ Chowkhat Of Size 45 X 70 Mm Comprising Of Pvc Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wwod Powder/ Rick Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Stat Headed Ss Screws Having Minimum Frame Density Of 750 Kg/ Cum, Screw Withdrawal Strength Of 2200 N (Face) & 1100 N (Edge), Minimum Compressive Strength Of 58 N/Mm2, Modules Of Elasticity 900 N / Mm 2 And Resistance To Spread Of Flame Of Class A Catogory With Property Of Being Termite/ Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With Ms Hold Fast/Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge (M.S. Hold Fast/ Lugs Or Ss Dash Fasteners Shall Be Paid For Separately). , Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Plain Flush Door Shutter Of 35 Mm Thick Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Having Minimum Density Of 650 Kg/ Cum And Screw Withdrwal Strength Of 1800 N (Face) & 900 N (Edge), Minimum Compressive Strength 50 N Mm2 Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Catogary With Property Of Being Termite/ Borer Proof, Water/ Moisture Proof And Fire Retardanat And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws, All As Per Direction Of Engineer-In-Charge (Note:- Stainless Steel Butt Hinges And Necessary Ss Screws Shall Be Paid Separately. , S&F Mild Steel Work As Hold Fasts, Bands, Straps, Supports Or Stays For Pipes Eaves Gutter Including Bolts If Required, Hooks (Stay), Clamps And Similar Small Articles, Conforming Tofe 310-0 Or Fe 410-0 Complete All As Specified And Directed. , S&F 100Mm Size Ms Butt Hinges, Medium Weight, Cold Rolled And Fixed Complete All As Specified And Directed. , S&F 150Mm Long Aluminium Tower Bolt And Fixed Complete All As Specified And Directed. , S&F 125 Mm Size Aluminium Handle Plate Type Anodised Complete All As Specified And Directed. , M & L For Roof Surface Must Be Pressure-Washed With Water With, Is To Be Used To And/ Or Remove All Dirt, Dust, Chalking And Waste Products. Remove Algae, Mold By Using Bleach Solution. 2 Tiles Joint Repair All Visible And Joint More Than 0.50Mm And Not Giving Hollow Sound, On The Tiles Roof Or At The Junctions Of Flat Roof & Vertical Parapet Wall, Pipe Joints, Should Be Cut And Widen V Shape With Mechanical Cutter In The Size (6Mm W X 6Mm D) And Fill With Pmm Methodology.Glass Fiber Apply Urp Or Primeseal A On The Well Prepared Groove, Allow To Cure Tack Free. Followed By Filling All The Joints Covering The Entire Area Uniformly With Suitable Chemical. Allow Chemical To Cure A Minimum 24 Hours. Apply Minimum 50Mm-100Mm Width 45 Gms Glass Fibre Mesh/ Non-Woven Geo Testile Fleece With The Coat Of Roofseal Classic Along The Length Of Crack When The 1St Coat Is Still In Wet Condition. Apply The Second Coat With An Interval If 4-6 Hours. Waterproofing: Apply A Coat Of Roofseal Classic (Diluted With Water In The Ratio 2:1) As Self Priming 14.0-18.0 Sq. Mt/Litre.Allow Coating To Dry For 3-4 Hours. Applt Two Coats Of Dr Fixit Roofseal Classic/Litre/Coat, Without, The Rate Of Application Being The Same For Both The Coats. This Would Ensure Correct Consumption Of Material That Will Deliver A Total Of Dft Of Microns. Allow The System To Air Cure For 5 Days Minimum. Check To See No Void Surface Is Left Untreated/Uncoated. The Material Having Following Technical Specification As Per Astm D 6083 M- Type Ii, Attains A Tensile Strength Of 2.5 N/Mm2 Confirming To Astm D 2370: Elongation At Break 300% Confirming Astm D 2370, Adhesion To Concrete 2.0N/Mm2 Confirming Astm D 4541 And Crack Bridging Ability Up To 2Mm, Air Cure The Coating For 7 Days Before Water Pound Test For 48 Hrs. The System Comes With 7 Year Waterproofing Warranty From Service Provider. For Vertical Surface : Apply 2 Coat Of Dr Fixit Roofseal Classic With Forced Coverage Of /Litre/Coat. Entire Terrace Should Be Coated With Roofseal Classic Alongwith Parapet Walls Needs To Be Enveloped With Roofseal Classic/Raincoat System. The Total 3 Coats Treatment Inclu Taking Down/Dismantling Of Old Tarfelt/Old Unserviceable Roof Treatment From Reinforced Cement Concrete Roof By Scrapping, Broomig And Washing With Water Etc Including 10Mm Thick Rendering In Cm 1:3 With Water Proofing Compound Complete All As . Make : Dr Fixit, Asian Or Equivalent (Note : The Treatment Should Be Carried Out Through Authorised Applicator Only) , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 500 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Complete All As Specified And Directed. , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 1000 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Complete All As Specified And Directed. , S & F 20Mm Dia Aluminium Alloy Anodised Curtain Rod Decorative Fency Type With Brackets Complete All As Specified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttarakhand View Result →
26.
Agriculture #11175867 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Clearing And Grubbing Road Land Clearing And Grubbing Road Land Including Uprooting Wild Vegetation, Grass, Bushes, Shrubs, Saplings And Trees Of Girth Upto 300 Mm, Removal Of Stumps Of Such Trees Cut Earlier And Disposal Of Unserviceable Materials And Stacking Of Serviceable Material To Be Used Or Auctioned, Upto A Lead Of 1000 M Including Removal And Disposal Of Top Organic Soil Not Exceeding 150 Mm In Thickness As Per Morth Specification Clause 201. By Mechanical Means In Area Of Thorny Jungle , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 50 M As Per Morth Specification Clause 305.3 , Carriage Of Earth, Sand, Lime, Morrum Manure Or Sludge For 5 Km. , Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. , Dismantling Stone Slab/ Terrazo Chip Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. , Carriage Of Building Rubbish Stone Metal (Grit And Ballast Etc.) Up To 50 Mtr Lead , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786) Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Providing And Laying Damp-Proof Course With Cement Concrete Grade M-150 (1 : 2 : 4) Mortar Prepared With 1% Solution Of Water-Proof Compound Complete As Per Specification 50Mm Thick. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Random Rubble Dry Stone Kharanja Under Floor. , Supply And Installation Of Multi Rib Proofing/Cladding Sheet Manufacture Out Of 0.50Mm Tct (Total Coated Thickness) High Tensile Zinc Aluminum Alloy Coated Galvalume Steel (As Per 150Gsm Zinc Aluminum Coated 550Mpa Tuekd Strength) Confirming To Is: 1397/Astm A-792 Sheet To Have Wide Pens 30Mm High Nb At 250 Centre And Centre Width Of 1020Mm Sheets Be Casted With Regular Modified Polyster System On A Continuous With Line On Centre For Face And With A Polyster Coating Respectively Sheet Shall Have Proportionality With Siphoned Plate Made To Prevent Leakage Sheet Shall Be Fixed By More Of Sell Drilling Lift Tapping Hot Dip Zinc Coated Hox Head Fasterner Of Size 12X14x55mm Long. The Sheet Shall Be Supplied In Cost One Length And For A Minimum Up To 12Mts With All Scaffolding. , Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu /Jalore (Red/Choclate/Black/ Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joints Etc. Complete Fine Finish : 12 Mm Thick . , Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) , Repair Of Door, Window Shutters Including Cost Of Material And Labour For Change Of Damaged : Style/Rail Of Teak Wood 30Mm Thick/ Aluminium Section 4Wide , Renewing Glass Panes And Refixing Existing Wooden Fillets : 5Mm Thick Plain Glass Panes. , Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge Window Openable. , Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Making Khurras 450 X 450Mm With Average Minimum Thickness 50Mm Cement Concrete 1 : 2:4 Over P.V.C. Sheet 1 Mtr. X 1 Mtr. X 40Micron Finished With 12Mm Cement Plaster 1 : 3 And One Coat Of Neat Cement, Rounding Edges And Making And Finishing The Out Let Complete. , Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Whenever Required. 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm/M2 , Providing And Fixing Welded Mesh/Expanded Metal Mesh In Frame Work, Flat Iron Beading 20X3mm Including Top Cross Laps Inside And Out Sides Welding, Iron Bolts, Crews, Clips Etc. Complete (Excluding Frame Work) Of Size. Welded Mesh 25 Mmx 25 Mm X 2.1 Mm , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Charge : Profile B , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing & Fixing Mica Of Approved Make For Inner/Outer Side Of Shutters With Fevicol & Nails Complete As Per Approved By Engineer In Charge. 0.8Mm Thick Mica , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 60 Mm As Per Drawings And As Per Is 15658:2006.And Materials Conforming To Morth Specification Clause 602 With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blocks. Category B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Granular Sub-Base With Close Graded Material (Table:- 400-1) Plant Mix Method Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (Crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.E Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (As Per I.S.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[Morth Specification : Clause 401]. By Mechanical Means. For Grading-Iii Material , Dry Lean Cement Concrete Sub - Base. Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Providing And Laying Water Proofing Treatment On Roofs Of Slabs By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : , After Surface Preparation, First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. , Laying Second Layer Of Fiber Glass Cloth When The First Layer Is Still Green . Overlaps Of Joints Of Fiber Cloth Should Not Be Less Than 10 Cm . , Third Layer Of 1.5 Mm Thickness Consisting Of Slurry Of Cement @ 1.289 Kg/Sqm Mixed With Water Proffing Cement Compound @ 0.670 Kg/Sqm And Coarse Sand @ 1.289 Kg/Sqm. This Will Be Allowed To Air Cure For 4 Hours Followed By Water Curing For 48 Hours. The Entire Treatment Will Be Taken Upto 30Cm On Parapet Wall And Tucked Into Groove In Parapet All Around , Fourth And Final Layer Of Brick Tiling ‘With Cement Mortar Or Any Other Approved Protective Coarse. (Which Will Be Paid For Separately) For The Purpose Of Measurement The Entire Treated Surface Will Be Measured , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Old Work (One Or More Coats ) , Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , One Or More Coats On Old Work. , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: Old Work (One Or More Coats). , Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Prepartion Of Base With Sand Papering, Primer, Putty, Etc Complete In All Respect Including Scaffolding And Safety Provision New Work , Old Work , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meter Lead : For Thickness Of Tiles 10Mm To 25Mm. , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. 1: 3: 6 Or Richer Mix. , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately). , For Fixed Portion Anodised Aluminum (Anodised Transparent 81 Dyed To Required Shade According To Is : 1868. (Minimum Anodic Coating Of Grade Ac 15, Anodizing To Be Got Done From Approved Anodizer) , For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Anodised Aluminum (Anodised Transparent 81 Dyed To Required Shade According To Is : 1868. (Minimum Anodic Coating Of Grade Ac 15, Anodizing To Be Got Done From Approved Anodizer) , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs/Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge. (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.) With Glass Panes Of 4.0 Mm Thickness ( Weight Not Less Than 10.0 Kg/Sqm) As Per Is : 2835. , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge. Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , P & F Soap Dish Or Tray Of Approved Quality/Make C.P. Brass , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : Size 580 Mm X 450 Mm , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : Size 630 Mm X 500 Mm Dia For Counter Top , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make :450 Mm , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P & F Kitchen & Lab. Sink Of Approved Make With C.I. Brackets Duly Painted, 40 Mm C.P. Waste Coupling, C.P. Brass Chain With Rubber Plug, 40 Mm G.I. Waste Pipe Up-To Floor Level Complete Including Cutting And Making Good The Wall & Floor : 1.0 Mm Thick Stainless Steel Aisi -304 & Is 13983-1994 Kitchen Sink Of Approved Make As Per Engineer-In-Charge With Large Waste Coupling. 45 X 20 X 8 20X16x8 (With Drain Board) , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- , Size 230 X110 X150 Cm.(For 20 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F Grating Of Approved Quality/Make: Stainless Steel Sheet Size 125Mm Dia. Heavy Quality Of Approved Make , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) 20Mm Nominal Size , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20Mm Nominal Size , 25 Mm Nominal Size , 32Mm Nominal Size , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: C.P. Brass Bib Cock,15Mm Nominal Bore. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings, This Included Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement , Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. (External Work). , 25 Mm Nominal Size , 32Mm Nominal Size , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: , Coupler (Socket) , 110Mm Dia , Plain Tee , 110Mm Dia , Bend 87 .5 , 110Mm Dia , Pipe Clip , 110Mm Dia , Providing And Fixing Superior Quality Pvc Tank Cover Complete As Per Approved By Engineer In Charge , Above 500 Lt. Capacity , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: , 1000 Ltr. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete : Solid Pvc (Is 2548 Marked) Grade-I White For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend As Per Is : 7231 . , Providing And Fixing Unplasticized Poly Vinyl Chloride (Upvc) Swr Pipes Type B For Sciland Waste Discharge System (Is:13592 : 1992 Marked) Of Approved Quality /Make 110 Mm Dia , Providing And Fixing Unplasticized Poly Vinyl Chloride (Upvc) Swr Pipes Fittings Type B For Sciland Waste Discharge System (Is:13592 : 1992 Marked) Of Approved Quality /Make 110Mm Dia , Coupler , Bend 87.5 Dg. , Bend 45 Dg. , Door Bend 87.5 Dg. , Single Tee , Vent Cowel
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
27.
Public Administrative Department #11162234 AOC
Providing Fixing Various Equipments And Appliances, Cctv, Water Purifier Etc And Electrification Work In Zakir Hussain Hospital, Nmc-1 P / F Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete 2 P / F, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) 3 P / F Testing And Commissioning Of 2500 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete 4 P / F 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete 5 P / F 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete 6 P / F, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Airconditioning Unit 1 Tr Having Iseer Minimum 4.50 Suitable To Operate On Capacity 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall Floor Mounting Type Complete With Refrigerant R410a / R32 And Copper Condenser At Position. 7 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. 8 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 2 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete 9 P / F Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. 10 P / F Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . 11 P / F 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. 12 P / F 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 13 P / F 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 14 P / F 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocoltcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. 15 P / F Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder 16 P / F 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 17 P / F 2Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 18 P / F 3Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 19 P / F Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete 20 P / Laying Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 21 P / F Testing Utp Connector ( Rj-45 ) 22 P / F And Configuring Broadband Router With All Accessories, On Provided Rack . 23 P / F And Configuring 8-Ports Managed Gigabit Switches Poe Smart Switch 24 P / F 6U Wall Mount Rack ( Dimension- Dxwxh – 450X550x367 Mm ) 25 P / Laying Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. . 26 P / F Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 27 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 28 Recharge Of Broadband Connection 29 Making Plumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 30 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 31 P / F Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling . 32 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories 33 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories . 34 P / F T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . 35 P / F Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 36 P / F 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 37 P / F 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 38 P / F Regular / Standard Model Ceiling Fan Complete Erected In Position 39 P / F Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 40 P / F ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 41 P / F Isi Mark Modular Type Electronic Step Regulator For Fan 42 Providing Aaa Batteries For Various Equipments As Required. 43 P / F Good Knight Machine For Mosquito Repellant Liquid. 44 P / F Refill For Good Knight Machine. 45 P / F Floor Cleaning Vaccum Cleaner Suitable For Operating On 240V / 50Hz Power Supply Complete. 46 P / F 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. 47 P / F Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 48 P / F 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete 49 Providing And Fixing 2 X 1.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 50 P / F 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 51 P / F 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 52 Providing And Fixing 2 X 6Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 53 P / F Isi Mark Modular Type Switch 6A 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete 54 P / F Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 55 P / F Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 56 P / F Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete 57 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected 58 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected 59 P / F Pvc Surface Modular Switch Box With Double Mounting & Front Plate For Modules Complete Duly Connected 60 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected 61 P / F Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse 62 Providing Fixing Marking Spmcb 6A To 32A, B- Series In Provided Distribution Board 63 Providing Fixing Marking Spmcb 40A To 63A C- Series In Provided Distribution Board 64 Providing Fixing Marking Dpmcb 6A To 32A, C- Series In Provided Distribution Board 65 Providing Fixing Marking Dpmcb 40A To 63A, C- Series In Provided Distribution Board 66 Providing Fixing Marking Tpmcb 6 A To 32A In Provided Distribution Board 67 Providing Fixing Marking Tpmcb 40A To 63A In Provided Distribution Board 68 Providing Fixing Marking Fpmcb 6 A To 32A In Provided Distribution Board 69 Providing Fixing Marking Fpmcb 40A To 63A In Provided Distribution Board 70 P / F Meter Box For Three Phase Energy Meter With Compartment For Mccb / Mcb Etc Complete. 71 Making Trench In Soft Soil For Laying Provided Cable . 72 P / F Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 73 P / F Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. 74 P / F Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. 75 Providing Premix Of Tea / Coffee For Vending Machine Refillng. 76 P / F Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 77 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 50 Cu.M Per Minute, With 12 Exhaust, Minimum 40 To 55 Litre Water Capacity Tank Complete. . 78 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute With 15 Exhaust Fan, Minimum 68 Litre Water Capacity Tank Complete. . 79 Providing Evaporative 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 80 Cu.M Per Minute With 18 Exhaust Fan, Minimum 75 To 80 Litre Water Capacity Tank Complete. 80 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. 81 Making Plumbing Works For Fixing Instant Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 82 Making Plumbing Works For Fixing Storage Water Heater / Gryser Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 83 P / Pasting Superior Quality Sun Control Film On Glass To Achieve Better Cooling Effect 84 P / Laying Telephone Black / Amba White Cadburybrown / Ruby Red / Ocean Brown Granite Stone Of 18 To 20 Mm Thick For Door Frame / Dado / Window Boxing Etc. On C.M. 1:6 Including Filling Joints With Polymer Base Filler Nosing / Moulding 85 Providing, Constructing Plinth For Substation Compound Required Excavation, Pcc In 1:2:4, 0.5Mtr Wide, 0.5Mtr Below And 0.5Mtr Above Ground In Cement Morter 1:6, Etc Complete As Per Rate Analysis. 86 P / F Fencing Of Section Having Size 2450 Mm In Height From Ground Level And 1200 Mm Width With Angle Iron Frame Work Complete 87 P / F Double Leaf Hinged Door Each 1500 Mm In Width X 1850 Mm In Height Using B Class, Gi Pipe With Angle Iron Supports, Chain Link Wire Meshcomplete 88 P / F 50 X 50 X 6Mm Angle Iron Corner Support 0.5M Away From Fence Support Fixed Etc. 89 P / F Gi Sheet 0.6 Mm ( 24 Swg ) To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. Complete . 90 P / F Marine Plywood 18 / 19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete. 91 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 92 Powder Coating In Siemens Gray Colour . 93 Making Iron Work For Fabrication With Bending, Cutting, Drilling And Welding Complete . 94 Providing And Applying Epoxy Paint With Anticorrosive Coating Etc Complete 95 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 96 Providing , Fixing And Erecting 6Mm Polycarbonate Multiwall Ultravoilet Protected Sheet For Roofing Over Fabricated Steel Structure As Per Detail Design, Including Fixing The Polycarbonate Sheet With Alluminium Angle & Flat Anodized & Dyed As Per Approved Shade Including All Water Proofing Materials, Nuts Bolts Hardware, Labour & Square Pipe, Angles, Fabrication Complete Including All Hardware Etc. As Required . ( Only Actual Area Of Polycarborted Sheet To Be Considered For Measurements ) 97 P / F Bracket For Set Top Box 98 Providing Stainless Steel Electric Kettle 99 P / F Co-Axial Copper Cable Low Voltage Grade Rg-11 100 P / F And Modifying Rfid / Coin System For Vending Machine Complete. 101 Providing Rfid Card / Coin For Vending Machine Complete. 102 Providing Hot Water / Tea / Coffee Storage Can Of 6 Litre Capacity. 103 P / F Water Cooler With Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 104 P / F Water Dispenser In Hot & Cold With Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 105 P / F Water Cooler With Ro + Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 106 P / F Water Dispenser In Hot & Cold With Ro + Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 107 P / F Insect Killer Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 108 P / F Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 109 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 110 P / F H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of High Density Polythyler And Built Corrugated Complete. 111 P / F Iam 15V Oil Free Medium Pressure Air Compressor Reciprocating Vertical Type Water Cooled Non Lubricated With Suction Air Filter With Silencer Watercooled After Cooler With Moisture Separator V-Belt Drive Arrangement Complete. 112 P / F Cooling Tower 10 Tr 113 Making Foundation, Water And Air Pipe Line With Complete Power And Control Cabling Loading, Unloading Trasportation, 114 P / F Automatic Control Panel For Emergency Alarm System Complete. 115 P / F Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 116 P / F Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 117 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 118 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 119 P / F Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 120 P / F Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete 121 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 122 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 123 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 124 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 7.5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 125 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 10 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 126 P / F Testing & Commissioning Approved Type Digital Key Telephone / Ip Telephone Instrument 127 P / F Testing & Commissioning Internet Protocol Digital Type Epabx For 10 Ip Extensions Complete. 128 P / F 8 Extension Card For Epabx System 129 P / F 16 Extension Card For Epabx System 130 P / F Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id Unit, Etc Complete . 131 P / F Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs 132 P / Laying Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . 133 P / Laying Unarmoured Telephone Copper Cable 10 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit 134 P / Laying Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 135 P / Laying Fr Grade, Pvc Armoured Multimode Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 136 P / F Configuring 1-Port Mini-Gbic Sx Mutlimode Fibre Transceiver 137 Supplying, Erecting, Testing And Commissioning Amplifier 700 W For Public Address System Suitable To Operate On 230 Volts A.C. / 12 Volts D.C. Supply Complete. 138 P / F Testing And Commissioning Sound Column 30 Watts Complete. 139 P / F Testing And Commissioning Microphone Complete 140 P / F Testing And Commissioning Stand For Microphone Complete. 141 P / F Testing And Commissioning Of 2 Core Shielded Microphone Cable Complete 142 P / F Testing And Commissioning Of 1.5 Sq Mm Speaker Wire Complete. 143 P / F Digital Ammeter For Measuring Current 144 P / F Digital Voltmeter For Measuring Voltage 145 P / F Multifunction Meter 146 P / F Selector Switches For Voltmeter & Ammeter . 147 P / F Light Emitting Diode Type Indicator 148 P / F Moulded Case Circuit Breaker . A Up To 100A. B 200A. C 250 D 315 / 400A. E 600 / 630A. F 800A. 149 P / F Sp Moulded Case Circuit Breaker. A Up To 100A. B 200A. 150 P / F Busbar Chamber With Triple Pole Neutral Aluminium Bus Bar A 100A. B 200A. C 300A. D 400A. E 630A. F 800A. 151 Providing And Laying Aluminium Conductor 3.5 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 25Sq.Mm B 35Sq.Mm C 50Sq.Mm D 70Sq.Mm E 95Sq.Mm F 120Sq.Mm G 150Sq.Mm H 185Sq.Mm I 240Sq.Mm J 300Sq.Mm K 400Sq.Mm 152 Providing And Laying Aluminium Conductor 4 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm D 16Sq.Mm 153 Providing And Laying Aluminium Conductor 2 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm 154 Providing And Laying Copper Conductor Core 2.5Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 155 Providing And Laying Copper Conductor Core 4Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 156 Providing And Laying Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete A 50 Mm B 75 Mm C 90 Mm D 120 Mm E 146 Mm F 160 Mm G 175 Mm H 200 Mm 157 P / F Heat Shrinkable Straight Through Joint Kit For 3 Core Etc Complete . A 70-120Sq.Mm B 150-185Sq.Mm C 240-400Sq.Mm 158 P / F Gi Strip Of Suitable Size 159 P / F M.S. Stand For Fire Bucket 160 P / F Wall Hook For Fire Bucket . 161 P / F G.I Fire Bucket 9Lit 162 P / F Instruction Chart 163 Pair Of Rubber Hand Gloves 164 Providing Standard First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc 165 P / F Fire Extenguisher Complete Erected With Necessary Clamp 166 P / F High Voltage Insulating Electromat Confirming To Is 15652 :2006 A Suitable For 3.3Kv. B Suitable For 11Kv. C Suitable For 33Kv. 167 Danger & Other Sign Board 168 Electrical Inspection, Compliance, Test Reports Of Earthing, Insulation Test Etc Complete. 169 P / F Analog Ammeter For Measuring Current 170 P / F Analog Voltmeter For Measuring Voltage 171 P / F Change Over Switches. A 63A. B 125A. C 200A. D 250A. E 315A. F 400A. G 630A. H 800A. I 1000A. 172 P / F C I Pipe Type Earthing Etc Complete. 173 Lt Panel, Changeover Panel, Distrubution Panel, Feeder Panel A Power Wiring Up To 63A Feeder Using Copper Wire, Lugs, Tie Saddle, Spiral Etc Complete. B Control Wiring For Metering Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral Etc Complete. C Panel Accessories Such As Hardware, Gasket, Insulator, Backlite, Panel Knob, Panel Lock, Push Button With Indicators, Heavy Duty Connectors Earthing Arrangement, Etc Complete For Following Feeders I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A D Dismantling, Disconnecting Connections Of All Cables, Shifting Old Panel In Godown Etc Complete Of Following Capacity. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A E Installation Of Panel At Desired Place Including Loading Unloading And Transportation Of Following Capacity I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A F Making New Terminations Of Main Incoming / Outgoing Cables, Etc Complete For Following Feeders. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A G Interlocking, Forward / Reverse, Timing And Control Circuit / Star Delta Circuit Etc Control Wiring Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral, Etc Complete For One Feeder. 174 Supplying Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete A 400 Mm B 450 Mm C 600 Mm 175 Dismantalling Temporary Hangging Wires Accessories, Etc Complete. 176 P / F 3 Phase Heavy Duty Industrial Socket. 177 P / F 1 Phase Heavy Duty Industrial Socket. 178 Tracing Out Faults And Attending Various Breakdown A Tracing Out Fault And Attending Minor Breakdown In Wiring / Electrification Etc Complete B Tracing Out Fault And Attending Major Breakdown In Wiring / Electrification Etc Complete C Tracing Out Fault In Lt Cable / Cable Kit / Panel Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. D Tracing Out Fault In Ht Cable / Cable Kit / Cubical, Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. E Attendance, Checking And Assistance For Total Electrical System During General Body Meeting. 179 Providing And Spreading Stone Metal 25Mm Size For 100Mm Depth Above The Ground Level. 180 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, With Operator For All Shifts Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 181 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, Without Manpower Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 182 P / F L.T. Current Transformer Of Suitable Ratio 183 Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Mccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 184 Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Mccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 185 P / F Flood Light Led Fitting A 30-40W B 50W C 70 To 80W D 90 To 100W E 120W F 150W G 200W 186 P / F Street Light Led Fitting A 70 To 75W B 75 To 90 W C 100 W 187 Supplying And Erecting Street Light Wall Bracket Made From 40Mm. Dia ‘B’ Class G.I. Pipe Complete . 188 Supplying, Erecting, Testing And Commissioning Self Contained Water Cooler 230 / 250V 50 Cycles Nominal Cooling Capacity Of 40 Litres / Hr And Storage Capacity 80 Litres With Partially Stainless Steel Body Complete.. 189 Providing Multimeter Of Range 0-10-30- 100-1000 Amps And 0-300-600 Volts, Continuity Tester, Ac, Dc Voltage Tester. . 190 Providing Insulator Tester ( Megger ) Cranking Type Having Metal Body Of Range 100 Volts 1000 Ohms . 191 Providing Tong Tester ( Clip On Meter ) Of Range 0-10-30-100-1000 Amps And 0-300- 600 Volts . 192 Providing Non Contact Voltage Detector Of Range 0-600 Volts . 193 Screw Driver With Green Neon Bulb Line Tester 3.6 X 60 Mm . 194 Providing And Fixing Triple Pole And Neutral Surface / Flush Mounted Distribution Board ( Tpndb ) A Distribution Board 12 Way ( 5-4-4 ) B Distribution Board 24 Way ( 5-4-5 ) C Distribution Board 36 Way ( 5-4-6 ) D Distribution Board With Door 12 Way ( 5-4- 10 ) E Distribution Board With Door 24 Way ( 5-4- 11 ) F Distribution Board With Door 36 Way ( 5-4- 12 ) G Distribution Board ( Spndb ) One Way ( 5-4- 13 ) H Distribution Board 4 Way ( 5-4-14 ) I Distribution Board 8 Way ( 5-4-15 ) J Distribution Board With Door 4 Way ( 5-4- 17 ) K Distribution Board With Door 8 Way ( 5-4- 18 ) 195 Reconditioning, Shifting And Installation Of Transformer. A Inspection Of Distribution Transformer On Hv And Lv Side B Dismantling The Distribution Transformer Of From The Plinth / Foundation C Providing And Filling Transformer Oil D Painting Of Transformer Using Smoke Gray Paint Complete . E Providing And Rewinding Of Copper Material For Ht Coils F Heating Of Core And Winding, Including Removing Of Moisture Etc Complete G Providing Oil Arresting Sheet For Low Tension Side Of R Y B Studs, 5Mm Thick Properly Fitted In The Studs Of Transformer. H Providing Oil Arresting Sheet For Top Cover Of Oil Chamber, Lt Connection Box, Oil Tank Etc Parts , 5Mm Thick Properly Fitted In The Top Cover And Nut Bolts Of Transformer I Providing R Y B Stud Bushings Over The Oil Arresting Sheet On The Studs Of Transformer . J Reinsulation By High Quality Uniform Covering Throughout Of 11Kv Windings Using Accessories Complete K Reinsulation By High Quality Uniform Covering Throughout Of 415V Windings Using Accessories Complete L Repairing And Servicing Of Tap Changer Of Transformer M Transformer Oil Filtration N Changing Silica Jel Of Breather And Adding Breather Oil. O Loading, Unloading And Transportation Of Transformer. P Attendance, Engineering Charges For Connection Of Ht / Lt Cables And Giving Satisfactory Test & Trials Of Transformer Complete 196 Providing, Constructing 1.5 Mtr X 1.5 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 197 Providing, Constructing 1.2 Mtr X 1.2 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 198 Providing And Fixing Rolled Steel Joist ( Girder ) Pole 116X 100 Mm. ( 23 Kg / Meter ) 11Rmt With Provided Base Plate In Provided Foundation As Per Specifications . 199 Making Isolation Circuit Using Ab Switch D.O. Set For Single Pole & Converting The Cutpoint By Dismantling With Nessasary Material, Jumping, Earthing Along With Arrangement Of Shutdown Etc. Complete. 200 Providing C.C. Foundation Including Excavation For The Poles 60 X 60 X 1.5 Mtr Deep In 1:3:6 C.C. ( 45 X 45 X 45 ) Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Appr. Manner . 201 Providing And Fixing G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height Complete 202 Providing And Fixing Ht Stay Wire 203 Providing And Fixing Approved Make, 11 Kv Lightening Arrestor With Necessory Accessories Etc Complete 204 Providing And Fixing Tension Porcelain Disc Type Insulator Suitable For 11 Kv Line Complete Erected With Suitable Hardware On Provided Cross Arms As Per Is. 205 Providing And Fixing Procelain Pin Type Insulator Suitable For 11 Kv Line, Complete Erected With Suitable Hardware On Provided Cross Arms. 206 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.09 Mm ( Raccon ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 318 Kg / Km 207 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.72 Mm ( Dog ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 394 Kg / Km 208 Providing And Fixing Air Break Switch Without Earth Switch 11Kv Outdoor Type Gang Operated Air Break, Triple Pole, 400A Switch Complete 209 Providing And Fixing Approved Make, 11 Kv Out Door Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Chanel With Working Curent Of 50 Amps Capacity Complete Erected On Provided Cross Arm. 210 Providing And Fixing Extra Thick Alkathene Pipe 10Mm Dia Erected To Enclose Bare Conductor Wires 211 Providing And Fixing Sundries Such As Earthing Powder, Danger Board Etc Accessories. 212 Providing M15 Grade Pcc Works For Plinth As Per Rate Analysis. 213 Designing, Providing, Fabricating, Installing Testing, Commissioning And Giving Satisfactory Tests Of Cubical Industrial Outdoor Type 2000A Lt Acb Changeover Panel As Per Detail Specifications, Making New Terminations Of Main Incoming And Outgoing Cables By Using Lugs Glands Etc Complete. 214 Repairing, Servicing Of 100Kva Dg Set A Providing And Filling Engine Oil 15W40 B Providing And Fixing Lub Oil Filter C Providing And Fixing Fuel Filter D Providing And Fixing Air Cleaner Inner E Providing And Fixing Air Cleaner Outer F Providing And Fixing V-Belt Set G Providing And Filling Radiator Coolant H Providing And Filling Radiator Cleaner 1Ltr Can I Dismantling Of Cylinder Heads, Turbo Charger, Refitting New Gasket, Checking All Allignments And Operation, Reffiting Assembly Again, Giving Test And Trial Complete. J Providing And Fixing Hose Pipe Set K Providing And Fixing Hose Clip Set L Providing And Fixing Fuel Pipe Set M Providing And Fixing O-Ring Set N Diesel Tank Cleaning O Servicing And Callibration Of Fip P Callibration Of Injector And Pressure Testing Q Servicing Of Charging Alternator R Servicing Of Starter Motor S Servicing Cleaning And Warnishing Of Main Alternator T Servicing, Overhaulling, Testing Of Avr, Epu Card, Relay Card, Etc Control Systems U Servicing And Overhaulling Of Turbo ( Dcarbonisation ) V Tappet Setting W Cleaning, Servicing Of Radiator And Refilling Coolant. 215 Repairing, Servicing Of Synchronization Panel By Updating Logic Software, Servicing Of Electronic Controller, Control Relays Terminations, Power And Control Wiring. Also Tightening Of Connections And Cleaning Of Panel Complete. 216 Servicing And Overhauling Of Ht Substation. A Servicing And Overhauling Of 4 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. B Servicing And Overhauling Of 2 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. 217 Servicing And Overhauling Of Transformer. Servicing And Overhauling Of Transformer By Changing R Y B Stud Bushing Of Ht, Lt Side, Oil Sheet For Low Tension Side Of Y B Studs, Top Cover Of Oil Chamber. Servicing Of Tap Changer, Taping Connections, Testing Of Oil Samples And Taking Insulation Test Of Transformer. Carrying Out Short Circuit, Open Circuit Test And Resistance Test Of Transformer. Changing Silica Jel Of Breather. Transportation, Attendance, Making Connection Of Ht And Lt Side As Well Giving Satisfactory Test And Trials Transformer. 218 Servicing Of Oltc By Checking Operating Mechanism, Alignment, Applying Jelly Various Parts, Checking Of Control Panel Operations And Replacement Of Provided Indicators, Switches, Control Fuses, Hardware, Insulator, Gasket, Polishing Contacts, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Termination Of Incoming Outgoing Cables Required. Cleaning Of Panel, Tightening All Connections Etc Complete. 219 Servicing And Overhauling Of Amf Panel. Servicing Of Contactor, Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Indicators, Push Buttons And Material Procured From Material List Like Voltmeter, Ammeter, Selector Switches, Termination Incoming Outgoing Cables As Required. Also Tightening Of Connections And Cleaning Of Panel Complete. A Up To 200A B 200A To 400A 220 Servicing And Overhauling Of Distribution Panels. Servicing , Repairing Of Distribution Panels By Checking Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Provided Indicators, Voltmeter, Ammeter, Selector Switches Termination Of Incoming Outgoing Cables As Required. Cleaning Of Panel, Tightening Of All Connections Of Feeders Following Capacity. A Up To 32A B 32A To 63A C 63A To 100A D 100A To 150A E 150A To 200A F 200A To 250A G 250A To 400A H 400A To 630A I 630A To 800A J 800A To 1000A K 1000A To 1250A L 1250A To 1600A
Contract Date: May 25, 2026 Contract Value : 23.96 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
West Bengal View Result →
Contract Date: Jun 02, 2026 Contract Value : 1.46 Crore
Statutory Bodies & Commissions/Committees No of Bidders 12
31.
Housing Urban and Rular Development #11147206 Price Bid
Tender for Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within Any Metres Lead Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Random Rubble Masonry With Hard Stone In Super Structure Above Plinth Level And Upto Floor Five Level , Including Leveling Up With Cement Concrete 1:6:12(One Cement : Six Coarse Sand : Twelve Graded Stone Aggregate 20 Mm ( Twenty Millimetre ) Nominal Size) At Window Sills, Ceiling Level And The Like.Cement Mortar 1:6 (One Cement : Six Coarse Sand) Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , 20 Mm ( Twenty Millimetre ) Cement Plaster Of Mix : 1:6 (One Cement: Six Coarse Sand) Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Finishing Wall With Weather Proof Exterior Grade Emulsion Of Approved Design (Apexultima) Or Its Equivalent On Undecorated Wall Surfaces (Two Coats) To Give An Even Shade And Final Finish After Throughly Cleaning The Surface To Remove All Dirt, Dust And Other Foreign Matter Etc Including Sand Paper Smooth Complete Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Including Cost Of Binding Wire Up To Any Level Above Plinth Level Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of Any Kilometre Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm ( Twenty Centy Metre ) In Trenches, Plinth, Sides Of Foundation Etc. Complete Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Steel Work In Built Up Section Trusses And Framed Work Including Hosting Fixing In Position And Applying A Priming Coat Of Red Lead Paint As Per Direction Of Engineer-In-Charge.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Fixing Stainless Steel Railing Of Apporved Shade & Design With 14 ( Forteen ) Gauges ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.).:Mounted Square Balluster System With Horizontal Members(Dt53-1-163)Of Tata Steel / Appolo , Kich Or Its Equivalent. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In Charge : 80 Mm ( Eighty Millimetre ) Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Stone Soling/Boulder Filling Dry Hand Packed In Under Floor Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand) : 4 Graded Stone Aggregate 20 Mm Nominal Size) Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Excavation In Foundation Trenches Etc. In Earth Work In All Kinds Of Soils Such As Pick Work , Jumper Work, Pick Work,Pick Jumper Blasting Work, Blasting Work In Soft And Hard Rock Conglomrate Rock Or Saturated Soil And Its Intermediate Classification Of Soil Including Chiseling/Wedging Out Of Rocks (Where Blasting Is Prohibited) And Pumping Or Bailing Out Of Watering/Dewatering Upto Any Lift Stacking The Excavated Soil Clear From The Edge Of Excavation And Then Returning The Stacked Soil In Layers When Required Into Plinth Sides Of Foundations Consolidation Each Deposited Layer By Ramming And Watering And Then Disposing Of All Surplus Excavated Earth Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying Cement Concrete In Retaining Walls, Return Walls,Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, Stringor Lacing Courses, Parapets, Coping, Bedblocks, Anchor Blocks,Plain Window Sills, Fillets,Sunken Floor Etc.,Upto Floor Five Level,Excluding The Cost Of Centering, Shuttering And Finishing : 1:3:6 (One Cement : Three Coarse Sand : Six Graded Stone Aggregate 20 Mm ( Twenty Millimetre) Nominal Size Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying Cement Concrete 1:6:12 (One Cement: Six Sand : Twelve Graded Stone Aggregate 40 Mm ( Forty Millimetre) Nominal Size) And Curing Complete Excluding Cost Of Centring And Shuttering In Foundation And Plinth Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Kota Stone Slab Flooring Over 40 Mm ( Forty Millimetre) (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1:4 (One Cement : Four Coarse Sand) : 25 Mm ( Twenty Five Millimetre) Thick Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Fixing Ornamental Ready Made Piller With Anarial Design Within All Leads And Lifts And As Per Hp.Pwd. Specifications Of 1990 Volume - I Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Fixing 0.60 Mm ( Zero Point Sixty Millimetre) Thick Prepainted Steel Sheet Roofing, With Hot Dipped Metallic Zinc Coated Sheet With Top Coat Of Regular Modified Polyster (Rnp) Organic Coating Of 20 ( Twenty ) Microns Over 5 ( Five Microns Primer Coating To Back Coat Of Polyster Of 5 Microns Over 5 ( Five) Microns Primer Coating I/C Fixing With Prepainted Iron J Or L Hooks, Bolts And Nuts 6Mm Dia Metre With Prepainted Limpet And Rubber Washers Complete With All Accesoriees As Requiredincluding Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Fixing Prepainted Ridges Or Hips 60 Cm (Sixty Centimeter) Overall With 0.60 Mm (Zero Point Sixty Millimeter) Thick Preprinted Steel Sheets In Roofing With Hot Dipped Metallic Zinc Coated Sheets With Top Coat Or Regular Modified Polyester Organic Coating Of 20 (Twenty) Microns Over 5 (Five) Microns Primer Coating + Back Coat Of Polyester Of 5 (Five) Microns Over 5 (Five) Microns Primer Coating Including Fixing With Preprinted Iron J Or L Hooks, Bolts & Nuts 6Mm(Six Millimeter) Dia And Preprinted G.I. Limpet And Bitumen Washers Complete With All Accessories As Required Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Steel Work In Built Up Section Trusses And Framed Work Including Hosting Fixing In Position And Applying A Priming Coat Of Red Lead Paint As Per Direction Of Engineer-In-Charge.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Fixing Of Ornamental Bench As Per Hp.Pwd. Specifications Of 1990 Volume-I Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm ( Zero Point Ninety Liter / Ten Square Metre ) Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm ( Zero Point Eighty Liter / Ten Square Metre )Of Approved Brand And Manufacture Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Supply Installation Testing & Commissioning Of Boom Barrier Of 4 Mtr ( Four Metre) Length Of Boom Arms. Galvanised And Ral Painted With Buil In Control Panel With Intensive Use. Manual Open / Close Buttons And Automatic Closing Ir Device Complete With Ground Loop Detection Board (For Entrance And Exit To The Main Building),100% Duty Cycle.High Intensive Use Dc Barrier. 180-200Nm Operating Torque For. 2 Sec Open/Close Time . Motor Current Draw : 12A. Max Motor Power: 300W.Max Opening : 90 Degree.Ip54. Inter-Changeable Barrier( Left To Right And Vice Versa). Ampereomatic Feature For High Safety In Case Of Failure Of Safety Device. Complete As Required As Per Given Technical Specification. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Supply Installation Testing & Commissioning Of Portable Spike Barieer Tyre /Killer Suitable To Work On Manual Operation .The Main Frame Is Made Of 6Mm Thick Flat Aluminum Strip Which Made It Corrosion Resistant,Strong And Light In Weight For Easy Portability & Long Durability. Other Details Are As Below, A. Portable Tyre Killer - 4 Mtr. B. Edge Of Spike - 10Mm, C. Height Of Spike - 60Mm, D. No. Of Spikes - 85 Nos. E. Total Weight : 7 Kg. (Approx.) F. No. Of Wheels In Packing Box - Two Etc. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto Any Metre And Lift Upto Any Metre . All Kinds Of Soil Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding Any Centyme Tre ) In Depth, Any Metre In Width As Well As Ten Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto Any Metre And Lift Upto Any Metre , Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding Any Cemntimetre In Depth, Any Metre In Width As Well As Ten Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto Any Metre And Lift Upto Any Metre , Ordinary Rock Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding Any Centy Metre In Depth , Consolidating Each Deposited Layer By Ramming And Watering, Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Extra For Every Additional Lift Of Any Metre Or Part Thereof In Excavation / Banking Excavated Or Stacked Materials. All Kinds Of Soil Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (One Cement : Four Coarse Sand) : Eight Graded Stone Aggregate 40 Mm ( Forty Mellimetre ) Nominal Size Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (One Cement : Two Coarse Sand) : Four Graded Stone Aggregate 20 Mm ( Twenty Mellimitter Nominal Size) Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum.( Three Hundred Thity Kilo Gram / Cubic ) Excess/ Less Cement Used As Per Design Mix Is Payable/Recoverable Separately). All Works Upto Plinth Level Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : Suspended Floors, Roofs, Landings, Balconies And Access Platform Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Edges Of Slabs And Breaks In Floors And Walls: Under 20Cm ( Twenty Centimetre ) Wide. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Supplying And Stacking At Site. Good Earth Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying Integral Cement Based Treatment For Water Proofing On Horizontal Surface At All Depth Below Ground Level For Under Ground Structures As Directed By Engineer-In-Charge And Consisting Of : (I) Ist Layer Of 22 Mm To 25 Mm ( Twenty Two Millimetre To Twenty Five Millimetre ) Thick Approved And Specified Rough Stone Slabover A 25 Mm ( Twenty Five Millimetre) Thick Base Of Cement Mortar 1:3 (One Cement : Three Coarse Sand) Mixed With Water Proofing Compound Conforming To Is:2645 In The Recommended Proportion Over The Leveling Course (Leveling Course To Be Paid Separately). Joints Sealed And Grouted With Cement Slurry Mixed With Water Proofing Compound. (Ii) 2Nd Layer Of 25 Mm ( Twenty Fiver Millimetre) Thick Cement Mortar 1:3 (One Cement: Three Coarse Sand) Mixed With Water Proofing Compound In Recommended Proportions. (Iii) Finishing Top With Stone Aggregate Of 10 Mm To 12 Mm ( Ten To Twelve Millimetre) Nominal Sizespreading @ 8 ( Eight ) Cudm/Sqm Thoroughly Embedded In The 2Nd Layer. Using Rough Kota Stone. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying Integral Cement Based Treatment For Waterproofing On The Vertical Surface By Fixing Specified Stone Slab 22 Mm To 25 Mm ( Twenty Millimetre)Twenty Five Millimetre) Thick With Cement Slurry Mixed With Water Proofing Compound Conforming To Is:2645 In Recommended Proportions With A Gap Of 20 Mm (Minimum) Between Stone Slabs And The Receiving Surfaces And Filling The Gaps With Neat Cement Slurry Mixed With Waterproofing Compound And Finishing The Exterior Of Stone Slab With Cement Mortar 1:3 (One Cement : Three Coarse Sand ) 20 Mm Thick With Neat Cement Punning Mixed With Waterproofing Compound In Recommended Proportion Complete At All Levels And As Directed By Engineer-In-Charge : Using Rough Kota Stone Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Placing In Position Suitable Pvcwater Stops Conforming To Is:12200 For Construction / Expansion Joints Between Two Reinforced Cement Concrete Members And Fixed To The Reinforcement With Binding Wire Before Pouring Concrete Etc. Complete : Dumb Bell With Central Bulb (180 Mm ( One Hundred Eighty Millimetre ) Wide, 8 Mm ( Eight Millimetre ) Thick) Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Making Soak Pit 2.5 M ( Two Point Five Metre ) Diameter 3.0 ( Three Point Zero Metre) Deep With 45 X 45 Cm ( Forty Five X Forty Five Centimetre ) Dry Brick Honeycomb Shaft With Bricks And S.W. Drain Pipe 100 Mm ( One Hundred Millimetre ) Diameter , 1.8 M ( One Point Eight Metre) Long Complete As Per Standard Design.With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Construction Of Pre-Fabricated Cabin Size (12.00X5.00X5.00)Mtr Roof Hut Shape As Per Dreawing. Specifications:-A) Outer Wall 50Mm Thick Wall Puf Insulated Panel.B) Roof Panel (30/70)Mm Thick Puf Panelc) Door And Window (As Per Drawing) Upvc.D) Ppgi Flashings (U-Channel & Corners). E) Hardware & Accessories.F) Erection Of Wall And Roof Panel.G) Tile Flooringh)Pvc Ceilingincluding All Civil Work Required I.E Foundation, Ooting, Plinth Beam Etc, Office, Toilets,Electrical Work ,Hvac,Fire Ighting,Plumbing & Sanitation,Earthing,Over Head Tank 5,000 Ltr, Septic Tank Etc As All Required Work Completed Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Himachal Pradesh View Result →
32.
Public Administrative Department #11142241 AOC
Construction And Carry Out Ancillary Works For Urban Ayushman Health Temples (Uhwc) In Porta Cabins At 14 Places In The Jurisdiction Of Thane Municipal Corporation.-1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. :Means Bd.A.1 Page No.259 2 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means 3 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. 4 Transportation of excavated material including loading and unloading etc. complete. (c) lead up to 5 km) 5 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. 6 Providing soling using 80 mm size trap metal in 15 cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. 7 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 8 Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 9 Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use).Spec. No As director by engineer incharge. Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec. No As director by engineer incharge. Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. 14 Painting letters upto 20 centimetre height including cost of brushes, coir brushes dusting, cleaning etcetera complete. Spec. No. As Directed By Engineer In Charge. Only For Road Side Furniture. Spec .No. MORTH 801 15 Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. 16 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. cover of 75 Kilogram with lid and frame fixed in cement concrete.. Spec. No. 17 Providing and laying in trenches 25 mm dai. UPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 18 Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying) 19 Providing and making ISI Mark ferrule connection of 25mm dia.to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. 20 Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters 21 Supplying, erecting, testing and commissioning of minimum three and above star rated centrifugal water pump (monoblock),230 V,single phase,50 Hz,AC.supply of 0.375kw/0.5 HP with discharge 36/9 lpm for head of 6/21 m & 25 mm suction /25 mm delivery pipe on provided CC foundation as per specification no.WP.CGP. 22 Supplying, installing and testing earthing with copper earth plate 30 x 30 x 0.315 cm complete with all accessories of copper materials and recording the results as per specification no.Ea-EP Supplying, & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 Kg.capacity cartridge type conform to IS 2878/15683 complete erected with necessary clamp made from 50 x 6 mm M.S. flat with nut & bolts rounded in wall complete. Supplying, & erecting Hand dryer machine having speed jet of warm air with low noise blower to quick dry wet hands,power 1800 W,voltage 230V,50 Hz.Automatic cut off after 5-10 second. Providing,Supplying and fixing electrical meter with all necessary accessories,required cable for connection from main supply including required permission from MSEDCL,TORRENT and Local authorities.(The contractor shall submit the original receipts of payments made to MSEDCL, Torrent Power co.The payments will be made as per the actual expenses made by contractor for each permission and purchasing of electric meter.) Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying and laying (including excavation) 50 mm outside dia double wall corrugated pipe (DWC) of HDPE for enclosing cable below ground/road surface to required depth completed Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Providing, Supplying and installation of Porta Cabin Fabricated at Factory Scope of work per cabin shall includes as follows 1. Specification mentioned as below 2. Internal and external arrangement of cabin as per drawings as attached 3. Works of Plumbing, sanitary, electrification, CCTV 4. Furniture as below a. Executive Chairs (as per sr.no.3) - 3 nos, b. Visitor chair (as per sr.no.4) - 6 no c. Two seater chair (as per sr.no.5) – 2 Nos d. Three seater chair (as per sr.no.6) – 5 Nos e. Patient Examination Couch/Table (as per sr.no.8) – 2 Nos f. Storage Cabinet (as per sr.no.9) – 1 Nos g. Table (as per sr.no.10) – 4 Nos h. Table (as per sr.no.11) – 1 Nos i. Medical Store Racks in pharmacy room (as per sr.no.12) – as per drawing j. Trash Bin (as per sr.no.13) – 6 Nos k. Seating tools (as per sr.no.7) – 6 Nos Detailed Description and Specification: Unit Size – L x B x Ht = 30 ft x 20 ft x 9 ft (Clear internal Height) Cabin should be structurally stable and suitable to meet severity of climatic conditions. Sustainable in wind condition of 55m/s- in Seismic zone IV and ambient temperature range (-) 40 degree C to (+) 50 degree C. Bottom Frame 80 x 40 x 2mm GI Rectangular Hollow Pipe (Apollo Make) Stiffener Bottom 50 x 50 x 2mm GI Rectangular Hollow Pipe (Apollo Make) for Shorter Span and 80 x 40 x 2mm for longer Span making the grid of 2ft x 2ft. Please note Base frame shall be quoted with special type of anticorrosive paint to avoid rusting and for better life (i.e. Black Coal Tar Epoxy Paint) Top Frame 80 x 40 x 2 mm GI Rectangular Hollow Pipe (Apollo Make) Stiffener (Top Frame) 50 x 50 x 2mm GI Rectangular Hollow Pipe (Apollo Make) for Shorter Span and 80 x 40 x 2mm for longer Span making the grid of 2ft x 2ft. Please note Base frame shall be quoted with special type of anticorrosive paint to avoid rusting and for better life (i.e. Black Coal Tar Epoxy Paint) Paneling Outside Outside Wall of the cabin shall be made from 16 guage GI sheet with solid color of approved shade, fitted on inside GI pipe framing making the grid of 2ft x 2ft. Paneling Inside Inside wall of the cabin shall be made from 3 MM Thk ACP sheet with aluminum foil thickness of 0.25 mm with solid color of approved shade fitted on inside Gl pipe framing making the grid of 2ft x 2ft. All the ACP joints shall be filled with Black silicon. Wall Panels shall be completely insulated with Glass wool of 48 kg/m3 Density and slab thickness 50mm. Corners Pole 72 x 72 x 3.2mm GI Rectangular Hollow Pipe (Apollo Make) with black coal tar epoxy coating Plumbing Arrangement UPVC concealed internal plumbing system shall be provided with all necessary inlet and outlet points as per the Drawing. External water connection shall be Provided by TMC. Drinking Arrangement Providing and Fixing branded water purifier of make like Aquaguard, Kent, LG or equivalent with all necessary connections, fittings accessories with storage arrangement etc. complete Sanitary Fittings All plumbing and sanitary fittings such as Ceramic Western Commode with seat cover, Ceramic Indian Commode, Ceramic urinal with push pillar cock, Ceramic Wash Basin, Wash basin Push Pillar Cock shall be of brand like Kajaria, Hindware, Paryware or equivalent. All western Toilets must be equipped with jet Spray, 2 in 1 Taps and Flush Tank. Accessories for PWD persons shall be provided in all toilets. (Excluding External Sewerage Connection). Roof Outside Roof Slope 1:2 one way 126 Roof shall be made from 1.2 mm 120 GSM GI sheets of Jindal make, which shall be fully welded and sloped to avoid leakage. All the roof joints shall be covered with 75mm Butyl Vinyl Tape. Roof shall be covered with Heat Resistant paint to maintain low temperature inside the cabin. Roof Gutter Specially designed gutter section shall be provided to drain water at the single side of the cabin. This shall be made from 1.2 mm 120 GSM GI sheet Jindal make including fitting arrangement. False Ceiling False Ceiling shall be made from 3 mm Thk ACP sheet with Aluminium foil thickness of 0.25 mm with solid colour of approved shade fitted on inside GI pipe framing making the grid of 2ft x 2ft. All the ACP joints shall be filled with Black silicon. Flooring Flooring shall be made from 18 mm High Strength Bison board/ Cement fibre sheet, which is covered with 2 mm PVC vinyl flooring for cabin. For toilet Cement sheet shall be covered by 10 mm thick 1 X 2 ceramic tiles which shall be fixed by using tile adhesive and cement mixture of at least 50mm Thk. Doors & Door frame Main Door Flush door 32 mm thick waterproof material with 4mm Glass as per approved design and drawing and door frame shall be made from aluminium Section. Locking arrangement along with D Handles in SS 304, door closer, door stopper etc. Door Size: 5’x 6’ Internal doors shall be sliding doors/ flush door of size as per drawing and as per the specifications decided by engineer-in charge Toilet Door and door frame shall be made from aluminium frame with 4mm Glass and ACP including locking arrangement, Handles in SS 304, Door Size: 2’-6’’ x6’ Windows Powder coated aluminium Two Track sliding windows with 4 mm tinted Glass. Size of windows as per drawings. M.S. Grill of weight @ 20 kg per sqm shall be provided to all windows/louvered window from outside. Curtains of good quality and curtain rod/track with fixtures shall be provided from inside of windows. Insulation False Ceiling and Wall Panels shall be completely insulated with Glass wool of 48 31 Providing, Supplying and installation of Porta Cabin Fabricated at Site Scope of work per cabin shall includes as follows 32 Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 Kilogram/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm, skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 33 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 34 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 35 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 36 Testing :- Compressive test of C.C.Cube 37 Provide and supplying Executive Chairs A generously cushioned, molded PU seat combined with breathable mesh fabric, Crafted from strong and durable Polyamide (Nylon) featuring a reinforced mesh back, chair equipped with BIFMA Certified Class-4 Hydraulic Gas Spring and BIFMA Certified 60mm Wheel Castors. Chair having 3 years warranty (Executive chairs) / or equivalent / as Directed by Engineer Incharge. Key Features Colour : GREY / Black Material : Metal Dimensions : 64D x 61W x 119H Centimeters Size : Standard Back Style : Mesh Back Special Feature : Adjustable Lumbar, Adjustable Height, Adjustable Arm Rest, Adjustable Head Support Seat Material Type : Breathable Microfiber Cloth Covered in PU Foam 38 Providing and supplying visitor chair having size Depth- 62cm, width-55cm, height- 80cm & seat height 45 cm. (+/- 2cm ), having seat & back, shall be made up of 1.2 cm hot pressed plywood, approved tapestry upto Rs.300/m and mould polyurethane foam with P.V.C. lipping all around etc. complete. The chair shall be provided with two one piece armrest made of polypropylene. The chair shall be supported by cantilever type powder coated tubular frame dia 2.54cm x 14 B G M.S.E.R.W. tube. All aluminium steel component shall have Epoxy Polyster Powder Coated. The chair shall be Ergonimc Dry film thickness shall be more than 45 Micron. And as directed by Architect in charge. The over all appearance of the product shall be as per photograph. All metal work shall be Epoxy Polyster Powder Coated and as directed by Architect in 39 Public Seating Chair. - 2 Seater Providing and Fixing 2 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish with 1 year warranty etc complete as directed by engineer in charge.. 40 Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 41 Seating tool for Lab and Class-IV Providing and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge. 42 Providing and supplying examination couch. This examination couch features an adjustable backrest that can be easily operated using a gas spring system. The twosection foam-padded top provides added comfort for patients during examinations. It is equipped with three drawers and three cabinets, offering ample storage space for medical equipment and supplies, keeping everything organized and easily accessible. A tray for the B.P. apparatus is conveniently placed near the headrest, ensuring easy access for medical professionals. The couch is finished with pre-treated epoxy powder coating, making it durable and easy to clean, while also ensuring resistance to corrosion Designed with a carrying capacity of 150-180 kg. etc complete. as directed by engineer in charge. Key Features Adjustable Backrest: The backrest is adjustable using a gas spring system, providing flexibility for various examination positions. Foam Padded, Upholstered Top: Offers comfort and support during patient examinations. Ample Storage: Equipped with three drawers and three cabinets to store medical supplies and equipment. BP Tray: A tray near the headrest for easy access to BP apparatus. 43 Providing, supplying and installing the cabinet, dimensions of 1200mm (W) x 1660mm (H) x 450mm (D) and is constructed from prime quality 0.8mm thick CRCA steel for the body panels and shelves. The shelves are adjustable in height and have a uniformly distributed load capacity of 50kg per shelf. The vertical sides feature continuous slots for mounting shelves at variable heights. The entire carcass is finished with a 50 ±10 microns epoxy polyester powder coating. The facia of the cabinet consists of metal shutters with metal borders, incorporating toughened glass panels. The handles are Dshaped in an aesthetically pleasing design with a stainless steel (SS) finish. The locking mechanism uses a metal cam lock for security. Additionally, the cabinet is equipped with adjustable levelers featuring plastic bases, allowing height adjustments of up to 15mm.This furniture is built according to the specifications and samples approved by the client. It meets the required certifications including ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, BIS standards, and is a BIFMA Gold certified member. The product comes with a 5-year warranty. Installation and other details are as directed by the engineer in charge. 44 Providing & Fixing of HNI Make table of Size. The Worktop shall be made of 25mm Prelam particle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. The above furniture should be as per specification with 3 years warranty etc. sample approved by client. TABLE SIZE :- W1060mm x D600mm x H750 mm -1 No W900mm x D300mm x H750 mm – 1 No W600mm x D450mm x H750 mm – 2 No As Directed by Engineer Incharge 45 Providing & Fixing of HNI Make table of Size. The Worktop shall be made of 25mm Prelam particle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. Legs are made of powdered coated steel 50mmx 50mm Section. Cross Member are in CRCA steel and the Beam is made of MS of 1.5mm thickness in powder coated finish of 50 microns thickness. The above furniture should be as per specification with 3 years warranty etc. sample approved by client. TABLE SIZE :- W1200xD700xH740mm As Directed by Engineer Incharge 46 Providing and supplying adjustable MS storage rack having size 1200 mm to 1800mm x 300 mm x 1600 mm including all transportation upto site etc complete as directed by engineer in charge. Key features 1. Material  Frame : Mild steel (MS) powder coated  Shelves: Cold-rolled steel (CRCA) or galvanized  iron (GI) 2. Angle Specifications  Size 40 x 40 x 2.50 mm  Length : Standard lengths of 6 feet, 8 feet, or 10 47 Providing and supplying trash bins with a maximum height of 450mm 35 - 40 liter, made of high-quality molded plastic for durability and ease of maintenance. The bins shall be equipped with a functional lid mechanism and shall be provided as per the approved selection and design. The work shall be carried out as directed by the Engineer-In-Charge etc complete . 48 Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. 49 Providing and Laying M60 grade cement concrete of approved mix design with avg. Flextural strength of 4.4 MPa in 3 days from R.M.C. plant incld. use of micro silica/alcofine, approved make super plastiser and retarder, fibriliated 100 % virgin polypropylene fibres, fly ash and transported by transit mixer and placing at work site. Compacting, finishing, initial curing by approved curing compound/contractors water and tarring the sides of slab with hot bitumen as specified and as directed (w/c ratio 0.28 max.). (vatta for curing will be paid separately) for Ultra thin White Topping (UTWT) pavement. etc completed. Providing second class Burnt Brick masonry with conventional/I.S .type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete Providing structural steel work in single stanchions composed of R.S.J. Channel etc. with caps, bases, mild steel plated, angle brackets, cleats, gusset plates, anchor bolts etc. as per detailed designs and drawings or as directed including cutting, fabrication, hoisting, erecting fixing in position, making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it two. coats of oil painting approved quality and shade etc. complete. Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meter made out of 4 mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity microprismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorized distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminum-Zinc alloy (55% aluminum 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) Providing Excavator (JCB JS 80 or equivalent) of 0.9 Cum etc complete Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec. One Number: As directed by Engineer- in-charge. Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing and laying Cast in situ/Ready Mix cement concrete M-15 trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing tuck pointing with cement mortar 1:3 for stone/Brick masonry including scaffolding and curing etc. complete. Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. Transportation of excavated material including loading and unloading etc. complete. ( (c) lead up to 5 km) Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing soling using 80 mm size trap metal in 15 cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer in charge. Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineerin- charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use).Spec. No As director by engineer in charge. Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec. No As director by engineer incharge. Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Painting letters upto 20 centimetre height including cost of brushes, coir brushes dusting, cleaning etcetera complete. Spec. No. As Directed By Engineer In Charge. Only For Road Side Furniture. Spec .No. MORTH 801 Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. etc
Contract Date: May 21, 2026 Contract Value : 4.09 Crore
Local Bodies No of Bidders 2
Maharashtra View Result →
33.
Tourism #11114098 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Cornices & Mouldings , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 150 Mm Strip Between Five Stone For Grassing.Strips To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.( Price Including Stone, Gardening Soil, Fertilizer And Grass Etc. ) , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Of Flashing Tape Along Wall And Tile Jointes ( Abutment Area ) Including Fixing Of Aluminium Strip Above Flash Including Sealing The Top Edge With Uv Resistant Sealant Etc Complete. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Extra For Plastering Done On Mouldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Mts. Lead. , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. A) Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. B) Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. C) Theming Work For Nandi Kalash In Frp As Per Tender Drawing , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Rough Dressing The Trenched Ground Including Breaking Clods. , Fine Dressing The Trenched Ground. , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Of Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevatia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Sebestena , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Foxtail Palms , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Callistemon (Bottlebrush Tree) , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Mimusops Elengi , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 60 To 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 40-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Pf=0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -5 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (A) 5 To 20 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying & Erecting Of Led 12W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A
Contract Date: Jul 02, 2026 Contract Value : 3.70 Crore
Government Departments No of Bidders 2
34.
Public Administrative Department #11109202 AOC
Tender For Yearly Civil Maintenance Work At Various Comm Complex And Etc For Pmpml-2 Excavation for foundation in earth, soil of all types, sand, gravel Cu.M and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m.) By Manual Means 3 Excavation for foundation in hard murum and boulders (Lift upto 1.5m.) Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) 4 Excavation for foundation in Soft rock and old cement or lime Cu.M masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means 5 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete 6 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to. 7 Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.. 8 (Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats )Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete 9 ( Providing and fixing mild steel grill gate ) Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 kg. to 20 kg. Per Sq.m.) Spec.No.: As directed by Engineer- in-charge. 10 ( PCC M20 for for bed blocks ) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood/steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand 11 Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks,laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structuralsteel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 12 ( Providing second class Burnt Brick masonry in plinth ) Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete. 13 ( Providing second class Burnt Brick masonry in superstructure ) Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 14 ( Providing second class Burnt Brick masonry half brick thick wall )Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. 15 ( Providing fly ash brick masonry in foundation and plinth ) Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. 16 ( Providing fly ash brick masonry in superstructure ) Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 17 Damp proof course 50 mm thick in M20 cement concrete : Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete 18 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. 19 Providing waterproof plaster in W.C. and bath 12 mm thick for dado : Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kg. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) 20 Providing and applying water proofing treatment using acrylic polymer : Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coat using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on StampPapers etc. complete. 21 internal cement plaster 20mm thick : Providing internal cement plaster 20mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. 22 Rough cast cement plaster externally in two coats : Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. 23 Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. 24 Polished Tandur Stone flooring 25mm to 30mm thick in plain/ diamond pattern: Providing and laying Polished Tandur Stone flooring 25mm to 30mm thick required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. 25 polished Kadappa stone 25mm to 30mm thick ( sill ) , : Providing sills of polished Kadappa stone 25mm to 30mm thick, on a bed of 1:4 cement mortar including cement float, filling joints with slurry, curing polishing and cleaning 26 ceramic tiles of having size 30 cm x 30 cm : Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. 27 ceramic tiles of having size 30 cm. x 30 cm. : Providing and laying ceramic tiles of having size 30 cm. x 30 cm.and confirming to corresponding I.S. for dado and skirting inrequired position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 28 vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness a) Flooring : Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Flooring 29 Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. 30 two coats of flat oil paint of approved colour to the old structural steel work : Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. 31 Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 32 Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. (on already painted surface) 33 two coats of exterior weather shield paint : Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item No. 15 to 18 prior approval of Superintending 34 White-wash in two coats on old / new plastered : Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 35 Plastic emulsion paint to old surfaces in three coat : Providing and applying plastic emulsion paint of approved quality, colour and shade to old surface in three coats including scaffolding,preparing the surface. (excluding primer coat). 36 Providing and applying water bound distemper along with primer coats. Recommended companies: Asian, neroleck, Dulex 37 Corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) : Providing and fixing corrugated galvanised iron sheets of 0.63mmthick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 kg/sq.m.). 38 6.00 mm thick ISI mark Asbestos Cement Corrugated sheet roofing : Providing and fixing 6.00 mm thick ISI mark Asbestos Cement Corrugated sheet roofing including galvanisediron J or L hook bolts galvanised iron band bituminous G.I. washers, galvanised iron clamps, bolts, nuts and scaffolding etc. 39 valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 120 cm wide : Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 120 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete. (excluding painting to underside of plank). 40 Removing G.I. or A.C. sheet roofing : Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. 41 colour coated Zincalume profiled sheets for roofing : Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective 42 Solid core flush door shutter commercial in single leaf 32 mm : Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. 43 Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S.62481979) (Without mechanical gear) 44 Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). 45 Alluminium sliding windows two tracks d) with powder coating without box : Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating without box 46 Acrylic plastic sheet panels to doors/windows (a) 2.00 mm thick : Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors/windows including providing and fixing clips, putty etc. complete. (a) 2.00 mm thick. 47 Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. 48 Partition of CCTW frame and commercial ply : Providing and fixing partitions made up of CCTW frame of size 75 mm x 50 mm at 60 cm c/c with 9 mm thick commercial ply and 4mm thick veneer on both sides with French polish etc. complete. 49 Aluminium partition partly glazed and partly laminated : Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 128231990,laminated on both sides,Novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubber cushioning beading to glass partitions as per approved drawing etc. 50 push cock (Self closing tap) symet type of 15 mm dia. : Providing and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete 51 White Glazed Earthenware full stall type Urinal with P.V.C. flushing : Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall 52 white glazed earthenware Wash Hand Basin of 55cm. x 40 cm.size : Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 53 Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. 54 15cm x 10cm salt glazed stoneware gully trap : Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 55 concrete pipes of I.S.NP. class of 300mm diameter : Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 56 Brick Masonry Inspection Chamber 90cm x 45cm x 90cm : Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. 57 Orissa type white glazed earthenware 575 mm water closet pan : Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. 58 H.D.P container Syntex or alike one piece moulded water tank : Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters 59 H.D.P container Syntex or alike one piece moulded water tank : Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres. 60 P.V.C. Rain water pipes of 110mm outer diameter : Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes,inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment) 61 Providing and laying in walls/ceilings/floors 15 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 1.25 kg/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 62 Providing and laying in walls/ceilings/floors 25 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 2.49 kg/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 63 Providing and laying in walls/ ceilings/floors 40 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 3.68 kg/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 64 Providing and laying in walls/ceilings/floors 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 5.17 kg/metre necessary fitting remaking good the demolished portionwith filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 65 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. 66 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. 67 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete 68 Removing cement or lime plaster including disposing of the spoils as directed with all leads, lifts etc, complete. 69 Providing 1.5 mm thick pvc carpet of approved design n color &fixing at site as per site in charge instructions etc. completed. Note:- Dimensions would be considered as per actual carpet size fixed at site. 70 Transportation of material obtained from xcavation including soil, Cu.M rubble, bricks, RCC concrete, kerb stones, steel railing, iron pipes,channels etc. Obtained from dismantling, loading in a truck of minm.5 Cum.capacity or designed capacity and transporting within the municipal limits or anydesignatedplaceof corporation,unloading, stacking or spreading of material etc. complete.
Contract Date: May 18, 2026 Contract Value : 37.27 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
35.
Defence #11104420 AOC
Tender For Repairs / Re-Novation Of Ofti And Ofti Work Shop Buildings Inside Factory Area At Ofmk.; 1 Site clearence 2 FELLING OF TREE: Felling of tree exc.30 cm and not exc.100 cm girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50m and clearing site 3 GRUBBING UP TREE TRUNK : Grubbing up tree trunk of girth exceeding 100 mm and not exceeding 150 mm, including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable materials and removing of unserviceable materials to a distance n. exc. 50 m and clearing site. 4 Demolition of cement concrete of any description and in any position not otherwise specifically provided for.Complete all as specified directed. 5 Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar. Complete all as specified directed. 6 Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Complete all as specified directed. 7 Dismantling floor,heartor wall tiling including cement mortar bedding but nor baking removing serviceable tiles to stores and rubbish off the premises.Complete all as specified directed and directed. 8 Taking down : Taking downcement or cement lime plaster, any description on brick or stone walls, etc.including raking out joints, hacking for key, scrubbing down with water, etc. 9 Removing building materials etc.other than spoilupto a distance of 1.0 Km, including loading, unloading and stacking at the destination. 10 Brick work with sub class ‘B’ bricks straight or curved in plan with 1:6 cement mortar.Complete all as specified and directed. 11 Stone Masonry : Walling of Squared Rubble regular coursed Stonemasonry, well bonded, bedded and solidly hearted built in with 1:6 cement mortar, Complete in all respects as specified and directed. 12 Damp proof course to horizontal or vertical surfaces In cement concrete 1:2:4, type B-0, 40 mm thickincluding necessary formwork . 13 Flush Pointing with 1:4 cement mortar to square rubble, coursed, well bonded and solidly hearted built in cement mortar as directed. 14 Vitrified tiles : Supply and laying of Light shade vitrified tiles 10 mm thick (Square/Rectangle) polished , area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Floor tile finishglossy/mat/ antiskid will be as decided by EIC. Complete all as specified and directed . Make : Johnson, Orient bell, AGL as approved by EIC. 15 GRANITE : S&F Granite 25 mm thk (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Complete all as specified and directed. 16 FLOOR TILING :Supply & fixing Coloured non skid ceramic tiles in flooring, 7 to 8 mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell 17 SCREED BED : Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:6. Complete all as specified and directed. 18 Plastering : Rendering of 10mm thick plastering with 1:6 cement mortar on fair faces of brick work or concrete surfaces. Complete in all respects as specified and directed. 19 Rounding to edges of stone slabs / granite one edge,such as in steps, cooking platform, and other similar situations. Complete all as specified and directed. 20 Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets etc. complete as directed by EIC. 21 Taking down wooden wall panelling of any description and similar work as directed. 22 Snap grid : Supply and fixing of 605x605 mm snap gridGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners withand including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediatechannel with connecting clips across the intermediatechannel at 457 mm centre to centre. Complete all as specifiedand directed, Make : Armstrong 23 Supply and fixing of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. 24 POP ceiling : Providing 10 mm thick plaster of Paris(gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mmwith 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately). Complete all as specifiedand directed, Make : Armstrong 25 Ceiling board : (M&L) S&F Exposed metal frame ceiling with calcium silicate boardof siliceous and calcareous material reinforced with cellulose fibre / PVC laminated gypsum tiles with MPL film on rear side, 8 mm thk.for fixing in 600 mm x 600mm grid,Make: Gyproc/ La gyp 26 Door shutter repair : Taking down door shutter of any description exc. 1 sqm and not exc. 2 sqmand repairing and adjusting to the required size including fixing builders hard ware and refixing to the same opening. complete all as specified and directed. 27 Dismantlingof structural steel work including doors, gates, but excluding framed truss etc. Complete all as specified directed. 28 UPVC window / Ventelator : Supply and fixing factory made UPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension . Complete all as specified and directed. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, 29 UPVC window : Three track three panels sliding window with fly proofS.S wire mesh (Two nos. glazed & one no. wire meshpanels) upto 1.50m height made of (big series) frame116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Areaof window above 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionof uPVC extruded glazing beads and uPVC extrudedinterlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy bodywith single nylon rollers (weight bearing capacity tobe 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steelscrews etc. Profile of frame & sash shall be mitred cutand fusion welded at all corners, including drillingof holes for fixing hardwares and drainage of wateretc. After fixing frame the gap between frame andadjacent finished wall shall be filled with weatherproof silicon sealent over backer rod of required sizeand of approved quality, complete all as specified anddirected by Engineer-in-Charge. 30 UPVC door : Supply and fixing factory made uPVC white colour Three track three panels sliding door with fly proofS.S. wire mesh (Two nos. glazed & one no. wire meshpanels) made of (big series) frame 116 x 45 mm & sash46 x 82 mm both having wall thickness of 2.3+ 0.2 mm and single glazing bead/ double glazingbead of appropriate dimension. (Area of door above2.00 sqm upto 5.00 sqm) comprising of uPVCchambered frame, with in-built roller track and sashextruded profiles duly reinforced with 1.60 + 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionuPVC extruded glazing beads, uPVC extrudedinterlock and uPVC extruded Inline sash adaptor (ifrequired), EPDM gasket, wool pile, zinc alloy (whitepowder coated) handle with key on one side of extremepanels along with zinc plated mild steel multi pointlocking having transmission gear with keeps, zincalloy (white powder coated) cresent lock (if required).stainless steel (SS 304 grade) body with adjustabledouble nylon rollers (weight bearing capacity to be120 kg), G.I fastener 100 x 8 mm size for fixing frameto finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut andfusion welded at all corners, including drilling ofholes for fixing hardwares and drainage of water etc.After fixing frame the gap between frame and adjacentfinished wall shall be filled with weather proof siliconsealent over backer rod of required size and ofapproved quality, complete all as specified anddirectd. 31 steel wire cloth : Supplying and Fixing in repairs stainless steel wire cloth0.36mm nominal dia.(Guage 28) of wire and width of aperture 1.4mm to wooden / steel doors/ windows, including fixing with and necessary screws, nut bolts,nails and removal of existing damaged cloth etc., complete all as specified and directed 32 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.0 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 33 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.8 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 34 Wooden Wall panelling : S & F of Prelaminated particle board18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work. Complete as specified and directed at site. 35 Wooden panelling frame work : S&F of battens frame work using wooden clean sawn 2nd class soft wood battens of cross sectional area exc. 15 & not exc. 25 sq.cm at a spacing of 35 centres. Complete as specified and directed at site. 36 PCC paving : PCC 1:4:8 in floors/ pavingoftype D-2, 1:4:8 with 40mm graded aggregate,100 mm thick.Complete all as specified and directed. 37 Earth work in excavation in all kind of soils by mechanical means (Hydraulic excavator) means over areas exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge 38 Soling (or sub base) of spread thickness 150 mm with broken boulders or quarried stone, inter sticesfilled, surface formed and rolled and consolidated torequired gradient and camber. Complete all as specified and directed. 39 Hard core with broken stone/boulders of gauge not exc. 63mm, deposited, spread leveled in layers not exceeding 15 cm thick, and watered consolidated to required gradient & camber including watering. Complete all as specified and directed. 40 Moorum filling in floors or pavings laid in layers not exe. 15cm thick , spread leveled and rammed including watering. Complete all as specified and directed 41 Stone sett flooring (M&L) with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 42 Edge stones to flooring (M&L) with stone setts of size 250 to 300mm long x l50 to 200mm wide, and 450mm deep and and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 43 PCC paving : PCC 1:2:4 in floors/ pavingoftype B-2, with 40mm graded aggregate, 100 mm thick. Including finishing concrete surface even and smooth surface without using extra cement.Complete all as specified and directed. 44 Wearproof topping 20 mm thick using CC 1:2:4, as specified incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner). Complete all as specified and directed. 45 Supply of metalic floor hardener 46 Surface excavation not exceeding 30 cm deepand averaging 20 cm deep in hard / dense soil and getting out. Complete all as specified and directed 47 PCC FLOORING : Cement concrete of 100 mm thickness in floors, sub-floors, sub-bases, pavings etc. oftype B-1, 1:2:4 (20 mm graded aggregate) 48 Smoth finish : Finishing cement concrete surface even and smooth using extra cement. 49 CC Paver blocks : S&F of Machine pressed precastconcrete interlocking paver block any shape and sizeconfirming to IS 15658-2006 of 60 mm thickness, M-35Grade with grey cement & pigment (Coloured)Complete all as specified and directed. 50 CC chequered tiles :S&F of cement concrete chequered tiles with grey pigment cement and pigments(Coloured tiles) for pavements. size of tile 20cm x20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors.Complete all as specified and directed. 51 PCC paving : PCC 1:3:6 in floors/ pavingof type C-2, with 40mm graded aggregate, 100 mm thick.Complete all as specified and directed. 52 Forming 12mm thick Expansion joints for 100 thick slabsfilled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A. ’ Complete all as specified and directed. 53 Structural steel (S&F) : Structural steel work confirming to Fe-410 W (Gde-E-250) quality-A Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled forfixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, including application of one coat of Zinc chromate primer paint .Make:TATA, Jindal 54 Structural steel (S&F) : Structural steel work Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Steel confirming to Fe410W (Gde E-250 quality A). Make : TATA, Jindal, Complete all as specified directed. 55 Structural steel (S&F) : Mild steel bolts. purpose made. of dia. of neck n.exc. 12 mm with hexagonal orsquare head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long. Complete all as specified directed. 56 Roofing sheet : Supply and fixing of pre painted galvalume aluminium zinc coating GI basedcorrugated/ trapezoidal profile roofing sheets of thickness 0.5 mm having tensile strength of 550Mpa as in roof covering / cladding to wall with self tapping screws etc. Make : TATA / Jindal /Essar. Complete all as specified and directed. 57 Supply only of liquid water proofing compound for incorporating concrete.Make. Fosrac, BASF, SIKA 58 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in in lintels upto 1.5m clearspan, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating. complete as specified and directed. 59 Kerb stone : Providing precast cement concrete using Type-B1, 1:2:4 20 mm graded aggregatein window or doorcills, lintels, bressumers, steps, quoin blocks (for use with ma- sonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets,etc. with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar 1:4. Complete with joints to match . Complete all as specified and directed. 60 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in roofkerbs or mud stops, rounded orchamfered on edges.complete as specified and directed. 61 PCC : Plain Cement Concrete (1:2:4) Type B2 using 40 mm graded aggregate in foundations, floors, filling and mass concrete, Complete all as specified and directed . 62 RCC : Reinforced cement concrete (Type B1, 1:2:4 with 20 mm aggregates) in columns, pillars, piers, posts etc. Complete all as specified and directed. 63 REINFORCEMENT : Mild steel(TMT) bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specified and directed. . 64 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 100 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 65 SWG PIPE : Supply & fixing of 100 mm dia Salt Glazed Stoneware drain pipes Grade A, including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 66 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 150 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 67 SWG PIPE : Supply & fixing of 150 mm dia Salt Glazed Stoneware drain pipeslaid in trenches including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 68 Earth work in excavation of all kind of soils by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Complete all as specified and directed . 69 Returning, filling in of excavated soils, including spreading, levelling, watering and well ramming in layersnot exc 25 cm. 70 PVC PIPE : Supply and Fixing of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid or fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 71 PVC PIPE : Supply and Fixing of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 72 Cutting chases in brick wall, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit iring, etc., and making good, cutting not exc 10 cm girth. Complete all as specified and directed. 73 Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat surfaces. Complete all as specified and directed. 74 S & F ofG.I. Tubes of Size 40 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 75 S & F ofG.I. Tubes of Size 25 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 76 S & F ofG.I. Tubes of Size 1/2‘’(15 mm), medium grade including all fittings to walls and ceilings or in floors/trenches. 77 Supply & Fixing Rotational moulded polyethylene water storage tanks (PVC cylindrical vertical with closed top) hoisted and fixed in position 1000 lit capacity. make : Syntex 78 BALL VALVES : 25 mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. Complete all as specified and directed. 79 NAHANI TRAPS : Supply & Fixing ofCI Nahani traps 100mm with grating including jointing to went pipe with CC 1:2:4complete all as specified and directed at site. 80 GULLY TRAP : M&L for PVC/SWR gully traps, of size 125 mm x 110 mm all as directed and specified. 81 GRATING : Supply and fixing of grating doom 100 mm dia. of PTMT (min. weight 25 gms) 82 PVC D/E PIPE CONNECTION :Supply and fixing of PVC Double End Pipe connection.in repairs, size:15mm with end nuts & washers of length 600 mm. Make : Kohinoor. Complete all as specified and directed. 83 ALUMINIUMPARTITIONS : Supply and fixing complete of anodised aluminium powder coated frames for partition frames and windows etc. all complete as directed by E.I.C. 84 ALUMINIUM WINDOW SHUTTERS : Supply and fixing complete of anodised aluminiumwindow and ventilator shutters powder coated fixed type without sash bar ,aluminium section weighing 0.55 kg/m including necessary jointig cleats, glazing clips, rubber neoprane packing, handles 2 nos. in each door, hinges, anodised aluminiumsnap beading, screws etc. complete all as directed by E.I.C. 85 HINGES : Supply and fixing of extruded Al. alloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-21 of size 125mmincluding all as specified and directed . 86 Antique aldrop : Supply and fixing of 200 mm long Antique model Brass mixed heavy alloy, sliding door bolt withsand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed.All as specified and directed and as approved by EIC. 87 Brass hinge: Supply and fixing of extruded brassalloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-11 of size 125mmincluding.All as specified and directed and as approved by EIC.. 88 Antique tower bolt : Supply and fixing of Antique model Brass mixed heavy alloy, barrel tower bolts of extruded section of size 200 mm and fixed all as directed.All as specified and directed and as approved by EIC. 89 Antique Door handle : Supply & fixing of Extruded Antique model Brass mixed heavy alloy, cast type polished bright handles 150 mm long, Complete all as specified and directed 90 TOWER BOLT : Supply and fixing of Aluminium anodised, barrel tower bolts of extruded section of size 200 mm and fixed all as directed. 91 BOW HANDLE: Supply & fixing of Extruded aluminium alloy handles 150 mm long, fabricated type, anodised. Complete all as specified and directed 92 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be easured separately), removing materials to store for keeping in safe custody for reuse at site and making good. 93 Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) 94 point wiring:S&F / Drawing of cables in PVC pipe,OneLight point or onefan point controlled by one switch with cables 1.5 sq.mm size of copper conductor cables FR PVC single core sheathed cable 95 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 5 amps independent, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 96 point wiring: S&F /Drawing of cables to One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 97 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 15 amps independent, with cables 4.0 sq.mm size of copper conductor cables FR PVC sheathed. 98 S & F of ceiling rose,3 phase/PVC/Polycorbonate, Isolate body 99 S & F ofswitch modular type of one module, 6 amps 100 S & F ofsocket, 2/3 pin combined, 6 amps, 2 Module 101 S & F ofswitch modular type of one module, 16 amps 102 S & F ofsocket, 2/3 pin combined, 16 amps, 2 Module 103 S & F ofFan step regulator 120 W, 2 Module 104 LED LUMINAIRE :Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/ Halonix 105 S & F of round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. 106 S & F of LED tube lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 107 LED Street Light :Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/Halonix.complete all as specified and directed 108 Exhaust Fan: Supplyand Fix Exhaust Fan made of sturdy Engineering plastic complete with Lauvers, Shutteers, voltage 230 V,50 HZ, RPM 1200, Copper winding ofsweep 250mm.complete all as specified and directed. 109 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) 110 Industrial socket plug: Supply and fixing of 240 V, 20 amps, single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB. 111 MCB :Supply and fixing of MCB / Isolator, 240 V, single pole 40 amp 112 MCB :Supply and fixing of MCB / Isolator, 240 V, double pole 40 amp 113 MCB D.B : S & F of Sheet Metal enclousers for D.B ofsingle doorof SPN,8 way with 200A rated bus bar,240V 114 MCCB: Suppply and fixing of MCCB 3 pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA. 115 S & F of Modular metal flush box 6 module 116 S & F of Modular white cover plate with frame 3 module 117 S & F of Modular white cover plate with frame 4 module 118 S & F of Modular white cover plate with frame 6 module 119 S & F of Modular white cover plate with frame 8 module 120 EARTHING : Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth lead GI strip 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.complete all as specified and directed 121 Earth continuity conductor : Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip. complete all as specified and directed 122 Dismantlng ofAsbestos cement (corrugated,semi corrugated, etc.) sheets in roofcoverings. Sheets shall be deposited to stores as directed. 123 Cutting or uprooting grass on old CC/brick tiles or on old mud phuska,and Taking down old Taf felt and loose material from the roof, cleaning the bitumen surface by wire brushing, washing down & disposing the pealed off tar felt muck etc. for complete as directed. removing rubbish off the premises, cleaning surface and preparing to receive new mud plaster. Complete as specified and directed. 124 Surface painting : Removal of old tarfelt sheets,Wire brushing and cleaning top surface of roof tops and surface painting, with a layer of bitumen primer for bitumen membrane @ 0.50 ltr/sqm by the same membrane manufacturere of density at 25° C, 0.87-0.89 Kg/ltr and viscosity 70-160 cps and then left the surface 4 to 8 hours for drying.Complete as specified and directed. 125 Bitumen Tack coat / Seal coat : Applying surface bitumen coat Seal / Tack coatwith lndustrial bitumen 85/25 forwaterproofingtreatments at the rate of 1.2 kg / sqm . 126 Water proofing treatment (M&L) : Rendering water proofing treatment to RCC roof slabs including vertical surfaces with APP based polymetric membrane sheet, minimum 3 kg/sqm and minimum 3.0 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) evenly laid on primed surfaces by forced applicationby torch on treatment. The vital physical and chemical parameters of the membrane shall be : Tensile strength in longitudinal and transverse direction at 23° C as 650/450/5 cm.Tear strength in longitudinal and transverse direction as 300/250 N. Softening point of membrane not less than 150° C. Cold flexibility shall be up to 2° c when tested in accordance with ASTM, D-5147. The laying of membrane shall be done through the authorised applicator of the manufacturer of membrane. Membrane make : STP / Dr. Fixt / IWL as approved by EIC. 127 Carrying and disposal of debris : Removing building materials etc. to a distance of 1.5 KM or under including loading, unloading and stacking at the destination. Complete all as specified and directed at site. 128 Rolling shutter : S&F ofSteel rolling shutters 1.25 mm thickness of lathe, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle. Complete all as specified and directed. 129 Rough excavation notexceeding1.5 m deepin drains etc in loose/soft soils andgetting out 130 Scarifying : Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exc.400 sqm and the thickness Exc 50 mm and n.exc 100 mm deep 131 Preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 132 Macadam : Premix bituminous, macadam with paving bitumen any penetration laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less).Complete all as specified and directed. 133 Pot holes : Repair to pot holes any depth, not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth,making good by applying tack coat @ 5 kg per 10 sq m, putting in premixed bituminous macadamusing paving bitumen, well rammed and sealed with binder 9.8 kg per 10 sq m, blinded with 0.09 cu m of stone chippings,6.3 mmsizeand again well rammed (including supply of premixed macadam, binder and chippings). depth of potholes exc 30 mm.Complete all as specified and directed. 134 Preparing Black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 135 Applying evenly a priming/tack coat with bituminous primer using paving bitumen at 5kg per 10 sq metre. Complete as specifiedand directed. 136 Bituminous premixed carpet, 2.5 cm consolidated thickness, with 0.34 cu.m. of stone chippings mixed with 18.25 kg of binder (paving bitumen)per 10 sq.m and mixed in mechanical hot mix plant and laid with mechanical paver and rolled using power roller 8-10 T capacity and compacted to required camber and gradient to uniform smooth surface. Complete as specifiedand directed. 137 Supply and fixing of Machine cut cudappah stoneslab 20-25mm thick over cementscreed base, laid and jointedwith grey cement slurry mixedwith pigment to match the shadeof the slab including rubbingand polishing complete. 138 Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint and application of priming paint plaster coat. 139 Rendering synthetic enamel painting on new Steel surfacesof any description over 10 cm width or girth- TWO coats including one coat of red oxide Zinc chrome paint. Make: Asian paints/Berger 140 Complete removal existing treatment of of white washing onsurfaces of walls/ concrete. 141 Complete removal existing treatment of of white washing on surfaces of ceilings. 142 CHALK WHITENING : M&L - Chalk whitening (white cement-based, water-resistant, white wall putty) of plastered surfaces as preparatory to distempering on wall surfaces, Make : Birla wall care, complete all as specified & directed. 143 PRIMER : Priming plastered and other surfaces with alkali resistant priming paint. Make : Asion/Dulux- all as specified and directed . 144 WHITEWASH ON CEILINGS : M&L - White washing on ceilings- on old decorated surfaces- including preparation of surfaces – ONE coat of White Wash-complete all as directed. 145 WHITEWASH ON WALLS : M&L - White washing on Walls – on old decorated surfaces- including preparation of surfaces - TWO coats of White wash - complete all as directed. 146 PLASTIC EMULSION PAINT:Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint-complete all as directed. Make: Asian -Apcolite / Dulux-promise. 147 OBD : M&L - Rendering Oil Bound Distempering on old surfaces -including preparation of surfaces on walls - TWO Coats of OBD - complete all as directed. Make : Asian-tractor Uno / Berger-Butterfly / Indigo-gold. 148 External weather proof painting on walls : Material & Labour for applying Two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces. all as specified and directed, Brand : Asian apex,Berger weather shield, Nerolac Rain coat. 149 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting onOld painted Steel surfaces- surfaces of any description over 10 cm width or girth including preparation of surfaces-TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 150 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on Old painted Steel surfaces- surfaces of any description n.exc 10 cm width or girth including preparation of surfaces- TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 151 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on wooden surfaces - old surfaces of any description over 10 cm width or girth including preparation of surface - TWOCoats- all as specified and directed-Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 152 FRENCH POLISHING : French polishing on old surfaces of any description, width or girth –including cleaning and preparing the surface- One or more coats. all as specified and directed. Make : Sheenlac, sealer 153 Supply and fixing of Safety lever locks mild steel with 4 levers for rolling shutters as directed. 154 Fan Hook: Supply and Fixing of Fan hook with double anchor bolt complete fixing as per instructions of EIC. 155 IWC : IWC of approved make fixed with P trap Make: Hindware/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 156 CONCEALED FLUSHING SYSTEM : Wall mounted concealed flushing system (including frame, control plate and installation kit) with dual flush mode of capacity 10 ltrs. Make: Jaquar(Solo)/ Parryware(Prime)/ Cera(Fountain). Complete all as specified and directed. 157 MIRROR : Mirror 5 mm thk. with bevelled edge fixed with concealed screws Make: Saint Gobain/ Nilkamal/ Casa Gold. Complete all as specified and directed. 158 Switch board box with frame plate and cover plate , metal flush box18 module: Supply and Fixing of covering plates with Metal Flush box andcover plate frames of 18 module of make Legrand/ Schneider/ Havellscomplete all as specified by the EIC 159 Concertina coil & 6 straight RBT strands : Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina cross type fencing, GI steel plate & GI core wireon wall top using concertina coils stretched to approx.6 meters length at site and clipped with three nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as C clips, R.B.T clips etc.). Including additional three horizontal R.B.T strands to be fixed with vertical portion of MS angle supports as directed in site. Complete all as specified and directed at site. 160 Accoustic sheets : supply and fixing of choice colourPolyester Fiber Acoustic Board / tiles, Thickness: 12mm, for insula-tion and accoustic purposes, 60x60 cm in size, fixed to wall / ceiling surfaces on snap grid orwith nails to timber frame work or with Z bar/clips etc as specified by manufacturer.Complete all as specified and directed. 161 Floor mat: supply and fixing of choice colourNylon carpet for floors minimum 6 mm thicknesshaving better accoustic co-efficient ,fixed to floor with approved adhesiveas specified by manufacturer.Complete all as specified and directed. 162 ACP wall lining : Supply and fixing of decorative choice colour solid finished Aluminum composit panel 4.0 mm thick sheeting on external wall surfaces upto 12.0 mter heights fixed over aluminium/MS framed wall surfaces as specified by manufacturer. Cost includes ACP panel, frame work, jointing glue and scafolding etc. Complete all as specified and directed. 163 UPVC window (Single glazed panel shutter & fixed wire mesh panel): Supply and fixing factory made uPVC white colour Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series)frame 47 x 50 mm & sash 47 x 68 mm both havingwall thickness of 1.9 ± 0.2 mm and single glass paneglazing bead of appropriate dimension (Area ofwindow upto 0.75 sqm.) comprising of uPVC multi-chambered frame, sash and mullion (where everrequired) extruded profiles duly reinforced with1.60 ± 0.2 mm thick galvanized mild steel sectionmade from roll forming process of required length(shape & size according to uPVC profile), uPVCextruded glazing beads of appropriate dimension,EPDM gasket, stainless steel (SS 304 grade) frictionhinges, zinc alloy (white powder coated) casementhandles, G.I. fasteners 100 x 8 mm size for fixingframe to finished wall, plastic packers, plastic capsand necessary stainless steel screws etc. Including SS wire mesh panel with aluminium beeding fixed to outer face window using adjustable /removable clips. Profile offrame & sash shall be mitred cut and fusion weldedat all corners, mullion (if required) shall be alsofusion welded including drilling of holes for fixinghardwares and drainage of water etc. After fixingframe the gap between frame and adjacent finishedwall shall be filled with weather proof siliconsealant over backer rod of required size and ofapproved quality, complete all as specified anddirected by Engineer-in-Charge. 164 WALL TILES : Supply & fixing of Coloured digital glazed ceramic tiles in vertical surface 300x600 mm set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell. 165 PVC door frame : S & F of solid WPVC Door Frame of size 100x60 mm heavy density of 11100 kg/cum and high quality PVC laminated of choice colour. Complete all specified and directed. 166 PVC door shutter : S & F of Factory Made Solid WPVCDoor Shutter with wood free EPS, 32 mm thick, heavy density 700 kg/cum and high quality PVC laminated on both side of choice colour. 167 Staircase railing : Supply and fixing of designed Stainless steel hand railing not less than 0.8 mtr height for stairs, balconies etc. using SS grade 304/316 members for balusters & rails etc. and covered with 12 mm thick tampered toughned glass. Design & model shall be as decided by EIC. Cost inclusive of glass, design and other mountings. Complete all as specified and directed. 168 Handicap grab bar : S&F of stainless steel anti slip vertical swing handicap bath room grab bar/rail with paper holder of min. 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 169 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 170 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 0.45 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 171 Wood Door : Supply and fixing of modern & designer soildTeakwood door shutters for Main Doors 32 mm finished thickness as decided by EIC . 172 EWC : Supply and fixing ofItalian Collection ceramic Floor Mount Western Commode, Rim less, One-piece for Bathrooms with Syphonic vortex Flushing system and soft closing seat cover including connection pipe.Make : Jaquar Fusion, Hindware Fabio, Cera cinova 173 WASH BASIN : Supply and fixing of Under counter Wash basin rectangle of approved make along with waste coupling, waste pipe and connection pipe, brackets etc. Make : Jaquar(Continental)/ Cera(campa)/ Parryware(Aqiline). Complete all as specified and directed. 174 URINAL : Supply and fixing ofSensor Urinal pan of approved make with auto flushing system including connection pipe, waste coupling and waste pipe Make: Jaquar(Aquisense)/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 175 PILLAR COCK : S&F ofsensorbased table top model Pillar cock with auto closing system of make: Jaquar / Hindware/ Cera. Complete all as specified and directed. 176 CONCEALED STOP COCK : S&F of CP Concealed stop cock of make : Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 177 2 WAY ANGLE COCK : S&F ofCP 2 way angle cock Make: Parryware(Uno)/ Cera(Fountain)/ Jaquar(Solo). Complete all as specified and directed. 178 EWC JET FAUCET : S&F of EWC jet faucet of make: Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 179 BIB COCK : S&F ofCP Bib cock of make: Jaquar(Solo)/Parrywaare(Uno)/ Cera(Fountain). Complete all as specified and directed. 180 SOAP DISH : S&F of SS soap dish of make Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 181 Hand drier: Supply and fixing of plastic Automatic Hot air drierfor bath rooms of approved make. Make :Orchid / Dolphy / Bajaj. Complete all as specified and directed. 182 Liquid soap dispensar: Supply and fixing of Liquid soap dispensar for bath rooms of approved make. Make :Jaquar / Orchid / Dolphy. Complete all as specified and directed. 183 Toilet paper holder: Supply and fixing of stainless steel single toilet paper roll holder of approved make. Make :Jaquar continental / Parryware sigma/ Cera Icon. Complete all as specified and directed. 184 Urinal partition : Supply and fixing of HPL (High-Pressure Laminate) urinal partitions using 12 mm thick compact board of width 400 to 500 mm and height 1200 mm of approved make and fixing with stainless steel brackts. Complete all as specified and directed. 185 Bldg.Expansion joint : Preparation of joint by grinding of groove surfae, remoal of dust, providing polymer mixed cement mortar on both sidea of groove and crack filling if any in floor level, fixing of baker rod 25x25 mm to control depth of groove, Providing and applying Nitoseal PU50 of Fosroc or equivalant having MAF 25% or above to the groove 25x12 mm. Including fixing / covering of joint with APP based polymetric membrane sheet sufficient width. Complete all as specified and directed at site. 186 Forming V grooves on granite surfacesn,exc 10mmdeep and n exc 10mm on face in steps, cooking platform, and other similar situations etc. 187 Hiring / Engage of JCB for cleaning, moving and loading materials like sand, gravel, or demolitionand removal of debris and other miscellaneous purposes as directd. The rate includes diesel and driver required to run the vehicle. 188 Carpet grass : Supplly and laying of carpet grass on levelled soil surface including preparing the soil bedby loosning the base ground 100 mm thick and removing old unwanted grass if any and necessary watering as directed. 189 Supply and laying of red earth / soil in loose state which is free from debris, grass and other vegitation to be used for gardening purposes as directed. 190 Architectural design : Before commencement of work Contractor should take architectural consultancy servies for entrance arch at the entrance gate, building front elevations and garden designs by authorised institutions / authorised Designer. Complete all as directed by EIC
Contract Date: May 16, 2026 Contract Value : 3.98 Crore
Government Departments No of Bidders 4
36.
Public Administrative Department #11103145 Price Bid
Tender For Repairing And Maintenance Of Civil Related Works In Pcmc Building Ward 23 Thergaon Gavthan For The Year 2025 26-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for thefoundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing, cutting, bending, hooking, tying and laying in position TMT FE 500 steel bars for reinforcement for all RCC works as per detailed drawings etc. complete. Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Lift Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. Lift 0.0 to 3.8 M Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor Lift 0.0 to 3.8 M Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats withC.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Ground Floor Providing and fixing green marble of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete. Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Skirting Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. Supplying hard murum/ kankar at the road site, including conveying and stacking complete. Spreading hard murum/ soft murrum/ gravel or kankar for side width complete Providing and applying two coats of lead/zinc base oil paint/bituminious paint of approved colour and shade to old wood work and fiber boards previously painted including if necessary scaffolding, preparing the surface excluding priming coat etc. complete. Providing and applying two coats of lead/zinc base oil paint/ bituminious paint of approved colour to new structural steel work and iron work in buildings including scaffolding if necessary, cleaning and preparing the surface etc. complete. excluding primer coat). Providing and applying two coats of flat oil paint of approved colour and shade internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface excluding primer coat) etc. complete. Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Ground Floor Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. excluding the primer coat.) etc. complete. Lift 0.0 to 3.8 M Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat scaffolding if necessary , and watering the surface for two days etc complete. Ground Floor Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. Ground Floor Providing, laying and fixing P.V.C. pipe of 20mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Ground Floor Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Providing and fixing push cock Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete. Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete. Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogram with frame etc complete. Providing and fixing M.S. grill door 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. Ground Floor Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing leak proof treatment by Injection grouting method to old floor without removing tiles of W.C., bath, with cement sand proportion of 1:1.5 and waterproofing compound at 2 Kilogram/bag of cement mixed in 35 liters of water including drilling holes in required position grouting with above mixed solution and ceiling etc. complete. Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters Ground Floor Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossingswith hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Ground floor Hire Charges for JCB including operator, disel, oil and other necessary mainatainance, labour etc. complete.nJCB 0.60 cum (JCB J S140/Tata Hitachi EX120) Hire Charges for tractor with trolly including operator, disel, oil and other necessary maintainance, labour etc Supplying mazdoor/unskilled heavy male labour etc. Removing and Transporting of excavated / demolished material within PCMC limit including loading, unloading, stacking the material as directed by Engineer-in-charge etc. complete. (For Lead 10.0 Km). Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
37.
Tourism #11101592 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In A) All Kinds Of Soil , Earthwork In Excavation In Trenches For All Leads & Lifts In All Type Of Strata Comprising Of Any Type Of Materials Either In Full Or Part As The Case May Be Adopting Any Method/Methods As May Be Convenient As Permitted Excluding Blasting In All Conditions Such As Dry, Moist, Foul, Saturated, Submerged, Etc,. Including Dressing Of Sides, Planking & Strutting, Timbering ,Ramming Of Bottom ,Pumping And Bailing Out Water ,Barricading Danger Lighting Guarding, Getting Out Excavated Soil & Stacking As Directed By Engineer For All Leads & Lifts Etc. Complete , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In Cm. 1 : 5 (1 Cement : 5 Coarse Sand) In Foundation Upto Plinth Level , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In Cm. 1 : 5 (1 Cement : 5 Coarse Sand) In Foundation Upto Plinth Level For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In:All Works Upto Plinth Level , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In B) In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Providing And Laying In Position (1:11/2:3) Reinforced Cement Conrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinfrocement (1 Cement: 1½ Coarse Sand:3 Graded Stone Agg 20Mm Nominal Size) All Works Upto Plinth Level , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc.Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level. M-25 Grade Of Concrete , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Foundations, Footings, Bases For Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. Cornices & Mouldings , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. , Rounding Of Edges Of Marble Slab To Semi Circular Slope , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm. Jet Black , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 600 X 500 X 75 Mm With Steel Reinforcement Not Less Than 2.25 Kg Per Unit , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) A) 20 Mm Thick. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto610mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete.140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Removing White Or Colour Wash By Scrapping, Sand Papering And Preparing Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Applying One Coat Of Cement Primer Of Approved Brand And Manufacture On Wall Surface. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling Doors, Windows And Clearestory Windows (Steel Or Wood) Shutters Including Chowkhats Architrave Holdfast Etc. Complete And Staking Within 50 Mt. Lead Of Area 3 Sq.M. And Below , Demolishing Cement Concrete 1:3:6 Or Richer Mix Including Disposal Of Material Within 50 M Lead , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Includingremoval Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground,For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charg , Providing And Fixing Statues (Lion Statue 3D View) Made Up Of Pop Of Size 3.45Ft X 4Ft Including All Fitting Fixtures , Finish Should Be Similar To The Photo Features References,Concepts Of Historic Eras Including All Tools, Plants, Labour And Materials, Leads, Lifts Etc Complete. As Directed By Engineer-In-Charge. , Supplying & Planting Shrubs, Creepers, Ground Covers, As Listed Below As Per The Nursery Size (0.3 - 0.45 M Tall) Including Providing, Spreading Preparing Soil Mixture , Adding Fertilizers As Per Planting Schedule,Garden Earth, Manure And Cocopeat Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Betel Nut Trees , Supplying & Planting Shrubs, Creepers, Ground Covers, As Listed Below As Per The Nursery Size (0.3 - 0.45 M Tall) Including Providing, Spreading Preparing Soil Mixture , Adding Fertilizers As Per Planting Schedule,Garden Earth, Manure And Cocopeat Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Lawn Selection One , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Spreading Of Sludge, Dung Manure Or/And Good Earth In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Making Lawns Including Ploughing And Breaking Of Clod, Removal Of Rubbish, Dressing And Supplying Doobs Grass Roots And Planting At 15 Cm Apart, Including Supplying And Spreading Of Farm Yard Manure At Rate Of 0.18 Cum Per 100 Sqm. As Per Morth Specification 307 , Maintenance Of Lawns Or Turfing Of Slopes(Rough Grassing) For A Period Of One Year Including Watering Etc. As Per Morth Specification 307 , Providing, Installating And Commissioning Weather Proof, Shock Proof Arihant Or Equivalent Make Double annual rate contract Swing Using Galvanized Steel, Pure Polyester, Nylon, Natural Rubber & Finished With Metal Colours/Roto Colours/Frp Colours With Following Details Product Size: 3.2M X 1.5M,Play Area: 4.2M X 2.5M, Including Concrete Foundation, Holding Down Bolts, Grouting With Plain Cement Concrete Of Ratio (1:2:4) Etc Complete With One Year Warranty As Directed By Engineer-In-Charge. , Providing, Installating And Commissioning Weather Proof, Shock Proof Arihant Or Equivalent Make Double annual rate contract Swing Using Galvanized Steel, Pure Polyester, Nylon, Natural Rubber & Finished With Metal Colours/Roto Colours/Frp Colours With Following Details Product Size: 3.2M X 1.5M,Play Area: 4.2M X 2.5M, Including Concrete Foundation, Holding Down Bolts, Grouting With Plain Cement Concrete Of Ratio (1:2:4) Etc Complete With One Year Warranty As Directed By Engineer-In-Charge. , Electrical Works , Supply Of 4 Core Armoured Pvc Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part Ii) With Latest Amendments Of Following Size. 4 Core 25 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Following Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade Complete As Required.4 X 25 Sq. Mm. , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core 10 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.(4) 4 X 10 Sq. Mm. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Lenghtwise On Top Of Cable All Over The Run And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (B) In Rocky Strata , Supplying And Laying 25 Mm X 5 Mm Gi Strip In 40 Mm Dia Gi Pipe From Earth Electrode As Required , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 2.5 Sq.Mm , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs. D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G)Watering Arrangement.(A) In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Supply Installation Testing and Commissioning of Outdoor Stand Mounted Feeder Pillar Made Up Of 16 Swg Crca Sheet With 32A Tpn Mcb Incomer, Single Dial Timer, 25A Cotactor For Automatic Switching Of Luminaries , Power Tool Control With 2 No. 9A Contactors And Raise Lower Push Button, Incoming 35 Sq.Mm And Outgoing 16 & 2.5Sq.Mm Terminals With Outgoing Mcbs 6 Nos. , Supply, Installation, Testing And Commissioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered In Design 50M/S, Is875:Part 3:1987•Material For Tubes Steel Of Grade Yst210.•Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts Ensuring Firm Grouting In The Specially Designed Reinforced Cement Concrete Foundation. The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Including Foundation Bolts, Frp Connectors And Mcb Preferred Make:- Suncity,Reytek, Havells, Leksa, La Luminite, Dwarka Casting , K-Lite As Directed By The Engineer Incharge , Supply Installation Testing And Commissioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body Withpressure Die-Cast Heat Management (Pdchm) And The Ip65 Opticalcompartment With High Power Led/S Is Comprised Of A Deep Drawnchemically Polished And Co-Extruded, Thermoformed Polycarbonate Protectorstabilized Agent Uv Rays Suitable For 50W Led. Fitting Shall Be Post Topmounting Type Fixture. System Wattage: 50W Led, Protection Class:Ip65,Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency:50-60Hz, Operating Voltage:1200- 277Vac, Operating Temperature: 0Deg To+50Deg C, Single Phase Ac Supply.● Light Source : Bridegelux, Ledlumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Lifespan:59,000 Hours,, ● Physical Body: Die Cast Aluminium Base, Bodyspun Aluminium, Diffuser: Convex Type Translucent / V Translucentpolycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powdercoated Black, ●Driver Power Factor:0.95, Thd:7.8%,Surge Protection:4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9And Having Surge Protection Device Of 4Kva And External Surge Protectiondevice Of 10Kva Make Philips. Leds Of Osram & Driver To Be Of Makephilips. Lm79-2019 Report To Be Provided.(Preferred Make:-:- Suncity,Reytek, Havells, Leksa, La Luminite, Dwarka Casting , K-Lite As Directed By The Engineer Incharge
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
38.
Tourism #11085444 Technical Bid
Tender For Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer. , Supplying And Filling Moorum In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry In Cement Mortar 1:3 (1Cement : 3 Coarse Sand) With Bricks Of Class Designation 75 Kg /Cm2. B. Upto Floor V Level. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs, Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of Sail, Tata, Vizag Made Only (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. Minimum Grade Of Steel - Fe 500 , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4B Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint.In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Providing & Fixing In Position Galvalume/Zincalume Flashings, Cappings, Ridges, Gutters Upto 600Mm/610Mm Girth And Min 3.00M In Length (Cold Rolled Steel 550 Mpa Yeild Stress Astm A 446 Grade E) With Hot-Dip Metallic Coating Of Aluminium-Zinc Alloy(Az 150 Galvalume) (150 Gms/Sqm Total Of Both Sides With Al-Zn Composition= 55% & 43.5% Resp. & 1.5% Si Conforming To Astm 792/ As 1397) 0.45 Mm Base Metal Thickness And 0.50Mm Total Coated Thickness, Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respects With Az 150 Gsm Smp Color Coated (20Mic Exterior Coat Of Silicon Modified Polyester Paint System Over 5 Mic Primer And 5 Mic Polyester Back Coat Over 5 Mic Primer) Incl. Fixing To Purlins With No 12X14X55Mm Mechanically Galvanised Hex Head Self Drilling Screws Of The Best Quality As Per As-3566 Class 3-4 Approved, Which Should Be Compatible To Be Used With Sheets. With Integral Washers And Epdm Seals Etc. Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. Plain Grill , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excludingfixingaccessoriessuchasnuts,Bolts, Fasteners Etc.). , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. Light Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Jet Black With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. ( Price Range 2000 To 2100 Rs Per Sq Mtr.) , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. ( Price Range 1550 To 1600 Rs Per Sq Mtr.) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm .80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Fixing 18Mm Thick Polished Black Granite Machine Cut For Kitchen Platforms, Counters, Window Sills, Door Frame, Urinal Partitions , Fascia And Similar Locations Of Required Size Of Approved Shade, Colour And Texture Laid Over 20Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing,Moulding And Polishing To Edge To Give High Gloss Finish, Etc. Complete At All Levels.( Price Range Rs.1500 To Rs.1700 Per. Sq.M ) , Providing 25Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 60 Cm L X45 Cm H X 15 Cm T , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand). 20 Mm Thick. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 (1 Cement: 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , 12 Mm Thick Cement Plaster 1:4 (1 Cement:4 Fine Sand) , 6Mm Thick Cement Plaster To Ceiling With 1:3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer , Extra For Plastering Done On Moldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws , Plugs And Priming Coat On Unexposed Surfaces Etc. 50X12Mm Size. , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 300X 16 X 5 Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Provided And Fixing 150 Mm Chromium Plated Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutters Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete. 200 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Window With 3 Tracks And 2 Shutters Sliding Window With Tobular Frame Ployster Powder If Thicness 75-80 Microns With Approved Standard Accessaries Such As Ball Beaing Rollers, Concealed Lock, 6Mm Thick Plain Clear Glass With Epdm Beading Etc. , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete. 10 Mm Dia , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete.12 Mm Dia , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead Extra For Dismantling Trusses, Rafters, Purlins Etc. Of Steel Work, For Every Additional Span Of One Meter Or Part Thereof Beyond 10 Mts. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Doors, Windows And Clearestory Windows (Steel Or Wood) Shutters Including Chowkhats Architrave Holdfast Etc. Complete And Staking Within 50 Mt. Lead. Of Area 3 Sq.M. And Below , Dismantling Wood Work Of Area Below 40 Sq.Cm. Wrought Framed And Fixed In Frames, Other Frames And Trusses Including Stacking Of Material Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Nandi In Frp As Per Tender Drawing , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Laying 300X350X160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete) , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Or Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Saraca Ashoka , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Nyctanthes , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Filliciam Decipiens , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Dichotoma , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Millingtonia Hortensis , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Jacaranda Mimosifolia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neolamarckia Cadamba , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevetia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Alba , Supplying & Planting Shrubs, Creepers, Ground Covers, As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. , Providing And Fixing White Vitreous China Type Water Closet Squatting Pan (European Type W.C. Pan) With Dual Flushing (Citren Nelson/ Similar)With Stop Cock Wall Flanges Flush Pipe Or Elbow And Vacuum Breaker Coupling Etc. Including Cutting Making Good The Walls And Floors Where Required. (Excluding Handicap Toilets) , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430 X 260 X 350 Mm And 340 X 430 X 265 Mm Sizes Respectively With Pvc Automatic Flushing Cistern With Fittings, R.S. Or C.I. Brackets, Standard Size Galvanized Steel Flush Pipe And Spreaders With Brass Unions & G.I. Clamps Complete, Including Painting Of Cistern And Fittings, Cutting And Making Good The Walls And Floors Where Required. (A)One Urinal Basin With 5 Liters P .V .C. Automatic Flushing Cistern. , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Including Cutting And Making Good The Walls Where Required. Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws. Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Wall Mixer With 3 In 1 System With 115Mm Long Bend Pipe For Connection To Over Head Shower Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing C.P. Brass Towel Rail Complete With C.P. Brass Brackets Fixed To Wooden Cleats With C. P. Brass Screws. 750X20 , Providing & Fixing Soap Dish Chromium Plated With Brackets Fixed To Wooden Cleats With Cp Brass Screw , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed .110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed. 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating.110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door :110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door :110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door 110Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door . 75Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Providing And Fixing R.P.V.C. Vent Cowl: 75Mm , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Cm2 In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar. , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:.B) 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 32Mm Outer Dia. , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 15Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 40 Mm Nominal Bore . , Providing And Fixing Non-Return Valve Of Approved Quality :40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality .25 Mm Nominal Bore , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 25 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 32 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 40 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 50 Mm , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701;1996. 1000 Lit. Capacity , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70B50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Wall Mounted Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length Complete. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (B) 10 To 40 A , Supply, Installation, Testing And Commissioning Of 3 Kva 1 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. (E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Square / Circular Max. 20 W Pendent Light With Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd10%, P.F. 0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Suspended Accessories Complete. , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii))
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
39.
Health and Family Welfare #11073758 Technical Bid
Tender For Major Works At Girls Ashram Hostel Merpur Kotda Udaipur- 1 Dismantling Doors, Windows And Clearatory Windws Steel Or Wood Shutter Including Chowkhats And Holdfasts Etc. 2 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meter Lead: For Thickness Of Tiles 10Mm To 25Mm. 3 Dismantling Gi Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes And Including Stacking Of Pipes Within 50 Meter Lead: 4 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. 5 Grading Roof For Water Proofing Treatment With Water Proffing Compound. Cement Mortar 1:4 (1Cement : 4 Coarse Sand) 6 Providing & Laying Broken Glazed Titles On Roof ( Broken Glazed Tiles Not Less Than 9 Kg/Sqm) On Top Of Hot Bitumen @ 1.7 Kg/Sqm. (1.40 Kg Of Vg-40 (30/40 )Grade And 0.30 Kg/Sqm. Of Vg-10 (80/100) Grade) And Joints Filled With Cement Mortar 1 :2 (1 Cement:2 Marble Dust Mixed With Water Proofing Compund All Complete As Per Direction Of Engineer-In-Charge. 7 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) 8 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) 9 Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete.New Plastered Surface (Three Or More Coats) 10 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 11 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm 12 Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete 13 Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Sqm Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3Mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge 14 Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). 15 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10Cm Long Embedded In Cement Concrete Blocks 15X10X10 Cm Of 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Require Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 16 Providing And Fixing M.S. Sheet 1Mm Thick Dabble Leaf Door Shutter In Angle Iron Frame 35X35X5Mm Suitabilly Diagonally Braced With 25X3Mm Flat Iron Above And Below Lock Rail Of Size 50X5Mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint Add Extra For Double Leaf Shutters. 17 Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3Mm With Suitable Screw At Not Exceeding 150Mm Distance. 18 Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. 19 Repair Of Door, Window Shutters Including Cost Of Material And Labour For Change Of Damaged : Aldrop Of Mild Steel 12\ Long X12Mm Dia 20 Steel Hinges For Wooden Chowkhat 4\ Size. 21 Steel Handle 6\ Size 22 Labour Charges For Repair To Door / Window Without Using Any Material Such As Applying Randha (Finishing) Tightening Of Bolts & Screw Etc. 23 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 24 Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated „J‟ Or „L‟ Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified. 3.0Mm Thick (Wt. 5.0 Kg./Mtr. Sq.) 25 Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: 26 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 27 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 28 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture : 29 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 30 Providing And Laying Ceramic Mat Floor Tiles (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown Of Any Size, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 31 P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440Mm. 32 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) 15 Mm Nominal Size 33 20Mm Nominal Size 34 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings, This Included Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement , Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.(External Work).15 Mm Nominal Size 35 20Mm Nominal Size 36 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 75 Mm Dia 37 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia 38 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia 39 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Coupler (Socket) 160 Mm Dia 40 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Plain Tee 160 Mm Dia 41 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Tee 110Mm Dia. 42 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 110Mm Dia. 43 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 160Mm Dia. 44 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 110Mm Dia. 45 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 160 Mm Dia. 46 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Bend (Top Side) 110Mm Dia. 47 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 110Mm Dia. 48 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 160Mm Dia. 49 P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design. 1000 Litres Capacity. 50 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 15Mm Nominal Bore. 51 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 25Mm Nominal Bore. 52 Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick C.C Bed Of 1:5:10, M-15 Grade C.C Floor & Rcc Slab Covering With M15 Grade C.C. Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140X150 Cm.(For 50 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect 53 Size 230 X110 X150 Cm.(For 20 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. 54 P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall :Size 550 Mm X 400 Mm 55 P & F Looking Mirrors With P.V.C. Frame Of Approved Make As Per Direction Of Engineer-In-Charge Size 500X400Mm 56 P & F Grating Of Approved Quality/Make:Stainless Steel Sheet Size 125Mm Dia. 57 P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: Brass 400 Gm,15Mm Nominal Bore. 58 Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade C.C. Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead.Depth Up To 0.5 M 59 Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick C.C. 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.-Do- Size 450 X 450Mm Depth Upto 0.5 M Cement Cover With Frame 60 Construction Of Soakage Well In All Type Of Soil With 300 Mm Thick Dry Masonry, Top And Bottom 300 Mm Course In Cm 1:6, 80Mm Thick Stone Slab, Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.C Flooring , Earthwork Complete As Per Approved Drawing Including Disposal Of Earth Within A Lead Of 50 Mtr.: Size 300 Cm. Dia Outside & 300 Cm. Depth . 61 P & F Flush Cock / Flush Valve (Is : 9758 Mark) For Wc Of Approved Quality Make : (-Do-) Half-Turn Exposed 25Mm Nominal Bore. 62 P& F Waste Coulping With Fittings Of Approved Quality /Make: C.P Brass 32 Mm Dia 63 P& F Waste Pipe With All Fitting G.I(B Class) 32Mm 64 Construction Of Open Drain With 112Mm Thick Brick Masonry In Cm 1:4 Semi Circular S.W. Glazed Channel (Confirming To Is Standards) Fixed With Cement Mortar 1:1 Over A Bed Of 100Mm Thick C.C. 1:5:10, Filling Of Edged With M-15 Grade C.C. Flooring, 12Mm Cement Plaster 1:4, Over All Exposed Faces, Excavation & Disposal Of Earth With In A Lead Of 50 Mtr Complete As Per Approved Drawings : 150 Mm Drain,225Mm Av. Depth Width 15 Cm S.W. Glazed Channel. 65 Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 150Mm 66 Supply Of Erw M.S. Black Casing Pipe Isi Marked (Is:4270/1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 150 Mm Nominal Bore Of Pipe 67 S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size: 150Mm Dia 68 S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. 69 Providing & Fixing Of Hdpe Pipe Confirming To Is:4984:2021 For Water Supply Suitable For Submersible & Jet Pump With Required Fittings Ie Socket, Elbows, Tee Etc. Complete In All Respect. For Vertical Installation 63 Mm Od 6 Kg / Cm2 70 For Horizontal Installation 63 Mm Od 4 Kg/ Cm2 71 Sitc Of Radial / Mixed Flow Water And Anti-Corrosive Liquid Filled Submersible Motor Pump Sets Suitable For 100/150Mm Dia Borewell. The Size Of Adopter Fixed On Top Of The Motor Should Exceed The Top Of Coupler , For Safegaurd The Coupler. The Job Includes Labour Part Of Lowering Of Riser Pipe G.I./ H.D.P.E. With Rope, Cables & Pump, Installation Of Complete Fitting And Accessories, Jointing Of Electrical Cables Up To Starter. All Labour For Testing Of Submersible Pumps Set And Supply Of Water To Water Mains, Complete In All Respect. 100 Mm Diameter Submersible Pump Shall Have Following Hp Rating, Phase, Head Range, Discharge Range Respectively. 3.0 Hp, 1-Ø, (40 -170)Mtr, (60- 20) Lpm Copper Wound 72 Sitc Of Ip 54 Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Coordination Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection(For Three Phase Pumps), Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps, 2P/4P Mcb Etc. Suitable For Following Rating Motors Complete In All Respect. For Three Phase Submersible / Mono Block Pump 3.0 Hp To 5.0 Hp ( Dol Starter ) 73 Providing & Laying Of Polypropylene Rope Confirming To Is:5175 For Submersible Pump Of Following Sizes. Complete In All Respect. 20Mm (Suitable For 90 Mm Od Pipe) 74 Supply And Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. 10.0 Sq.Mm 3 Core Flat / Round 75 Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItS Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Short Point (Up To 3 Mtr.) 76 Medium Point (Up To 6 Mtr.) 77 Long Point (Up To 10 Mtr..) 78 Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr On Board 79 Medium Point (Up To 6 Mtr.) 80 Long Point (Up To 10 Mtr..) 81 Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 82 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Blanking Plate 83 Modular Mcb 6 A To 32 A Dp (Is:8832 Marked) 84 Providing & Fixing Of Modular Type 100W Step Fan Regulator Duly Isi Marked (Is 11037) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Virgin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including Making Connections, Testing Etc As Required. 5 Step Fan Regulator 2 Module 85 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 1 X 1.5 Sq.Mm 86 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 87 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm 88 2 X 6.0 Sq. Mm. + 1 X 2.5 Sq. Mm 89 4 X 10.0 Sq.Mm 90 4 X 6.0 Sq.Mm 91 1 X 16.0 Sq.Mm 92 1X 4.0 Sq.Mm. 93 Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Glazed Door (Three Phase) Ik-09 And Ip-43 With Metal End Box 6 Way 94 Glazed Door (Single Phase) Ik-09 And Ip-43 With Metal End Box 12 Way (12+2) 95 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Single Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating 96 Double Pole Mcb(With B/C Curve Tripping Characteristics) 40 A Rating 97 Four Pole Mcb(With B/C Curve Tripping Characteristics) 50/63 A Rating 98 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners Etc. As Required. 32 Mm X 12 Mm 99 Making Of Hole In Wall (Brick/Stone) Of Required And Placing Np-2 Rcc Pipe Ring Of Required Size For Housing Exhaust Fan And Making Good The Same, With Cement Plaster Required Of Following Size. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Up To 457 Mm Size 100 P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 101 Providing & Fixing Of Heavy Duty Capacitor Start, Copper Wound Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 300 Mm Sweep(900/1400 Rpm) 102 P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Required. Up To 380 Mm Size 103 Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminium Housing With In Built Driver , System Lumen Efficacy ≥ 110 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1170Mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm 104 Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Surface Mounting (With Extruded Alumn. Housing ) Minimum Lumen Output 1600 Lm 105 Minimum Lumen Output 1950 Lm 106 Sitc Of Ip20, 1X1 Led Surface/ Recessed Mounting Backlit & Smd Mid Power Type Led Light Fixture Not Less Than 35 Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution.Operating Voltage Range 140-285 V, Hv Cutoff - Lv Cutoff Should Be 300-100V High Efficiency With 4 Kv Internal Surge Protection Bis Certified Isolated Driver Having Efficiency > 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) As Required. Surface Moutning Minimum Lumen Output 3600 Lm 107 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 108 Providing & Fixing Of Extra Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Including Cutting, Threading, Drilling, Fixing Quarter Pin Etc As Required. 109 Providing & Fixing Of 450 Mm Sweep Oscillating Type Wall Mounting / Pedestal Type Fans With Three Speed, On And Off Position, Sintered Iron Bush Oil Impregnated, With Metal Front And Back 120 Or More Ribs Guard; Three No. Aluminium Blades, Minimum Air Delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./Min/Watt, Noise Level Should Be 110 Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core 1.5 Sq.Mm Copper Conductor ,Making Connections, Testing Etc. As Required. 300 Mm Sweep 111 Supply And Installation Of High Tensile Low Carbon Steel Rod Molecularly Bonded With 99.9 % Copper Thickness (250 Microns) And Confirming To Ul 467, Is/Iec 62561-2 Of Following Size And Length And As Per Point Mentioned (A), (B), [C), (D), (E) Below :- (A) Bore A Hole Of Dia. 100 Mm Of Required Length, Place The Rod In The Centre Of Hole (B) Filled With Anti Corrosive Conductive Compounds With The Permanent Sealings At Both The Ends, Cpri/ Erda Tested With Rms Capacity Of Minimum 30 Ka For Withstanding 1 Second .To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Lab For Low Resistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Content As Per Referance Of Is 3043-1987,Ieee 80-2013 (Clause 14.5D) , Ieee 837 & Ier 1956 With Latest Amendemnts © Connect The Rod With Copper Strip/Conductor/Wire With Suitable Clamp Made From Tinned Copper And Ss 304 Bolt (D) Place Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. (D) Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. (E) Test Certificates For Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 17.2 Mm Thick And 3 Mtr. Long 112 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. 8 Swg Copper Wire 113 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led/ Integrated Lens Diffuser & Should Be High Power Led Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Integrated Metal Case Potted Driver & Has A Unique Bis R Number ( As Per Is 15885) With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac & Low Voltage Cutoff @>=90 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs As Required. Led Street Light Fixture With Minimum Lumen Output 2500 Lm 114 Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. 32 Mm Dia. 115 Supply & Fixing Of Dry Powder Agent (As Per Is 4308:2019), Abc Type Fire Extinguisher (Stored Pressure Type) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 28 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test (For Cylinder Body) Certificate From Oem / External Nabl Accrediated Lab Is To Be Submitted. 6 Kg 116 Sitc Of Ro Water System With Filteration Stages = Particilate Filter- Membrane Life Enhancer Filter- Sediment Filter- Pre Carbon Filter- Ro Membrane Filter- Post Carbon Filter. Input Power Rating -230V Ac, 50Hz, Percentage Of Rejection Tds-90% Or Better, Having Following Features (A) Double Purification By Ro With Ess Or Latest Technology With Tds Indicator. (B) Spin Welded Ro Membrane Housing To Prevent Tempering. (C) Push Fit Component For Leak Proof Performance. (D) Fully Automatic Operation With Auto Start And Auto Off. (E) Ss/Abs Construction For Corrosion Free Lifespan. (F) Equally Suitable For Water From All Borewells, Overhead Storage Tanks, Water Tankers And Even Municipal Taps. (G) Ro Membrane Flushing - Auto Flush@ Every Start, Every Stop And Every One Hour Of Working For One Minute, Complete In All Respect With Following Capacity. Purification Capacity - 50Lph, Duty Cycle 270-500 Liters/Day 117 Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs 118 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 119 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 120 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size). 121 Kerb Stones Of 1200X300X150, 1000X450X150, 1000X600X150, 600X300X150 Size (M-30) Providing And Laying Cement Concrete Kerb Stones Of Different Sizes In M-30 Grade (Manufactured With Fully Mechanised Dry Cast Process With Forced Action Mixer Whose Arms Revolve Along The Main Axis And Rotate About Its Own Axis Also, Having Humidity Sensor For Moisture Control Of W/C Ratio In Concrete Mix. Manufactured With Steel Moulds (Milled And Manufactured In Csi Diamond Or Csi Nitro Process For Accuracy) On Steel Base Plate Of Min 16 Mm Thick; Having Vibration And Pressing Action Both Together With The Help Of Multiple Synchronised Vibrators. Power Of Hydraulic Station Should Be Minimum 50Kw For Compaction And Cured In Controlled Chambers Having Humidity Control And Automated Air Circulation System) In Position To The Required Line, Level And Curvature Jointed With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Making Of Joints, Drainage Opening Wherever Required. 122 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 123 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 124 Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 125 Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix 126 Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix 127 Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. 128 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. 129 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) 130 Random Rubble Stone Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Five Level Above 30Cm. Thick Walls In : Cement Mortar 1:6 ( 1-Cement : 6-Sand). 131 Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 25 Mm Thick. 132 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 133 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 134 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 135 Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size).
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
41.
Power #11050522 AOC
Bids Are Invited For Boq Services Surface Dressing Of The Ground , Earth Work In Excavation , Excavating, Supplying And Filling Of Local Earth , Cement Concrete Of Specified Grade , Brick Work With Common Burnt Clay F.P.S. , Treatment Of Soil , Specified Grade Of Reinforced Cement Concrete , Centering And Shuttering Including Strutting Etc , Centering And Shuttering Including Propping Etc , Steel Reinforcement For R.C.C. , Structural Steel Work In Single Section , Steel Work In Built Up Tubular , Cement Concrete , Corrugated G.S. Sheet Roofing , 40 Cm Overall Width Plain G.S. Sheet , 12 Or 15 Mm Cement Plaster , Cement Concrete Flooring , 60Mm Thick Factory Made Interlocking Paver Block Of M -30 , Providing And Laying Vitrified Floor Tiles , Ceramic Glazed Floor Tiles Of Size 300X300 Mm , Insulated Sandwich Puf Panels , Insulated Sandwich Puf Panels, Having Tongue And Groove Joinery System , Precoated Galvanised Steel Sheet Roofing Accessories , Providing Wood Work In Frames Of Doors, Windows , Chromium Polished Iron Fittings With Screw , Aluminium Tower Bolts , Door Stopper , Stainless Steel Wire Gauge , Upvc Casement Cum Fixed Glazed Window , Upvc White Fixed Glazed Window Or Ventilators , Nickel Plated M.S. Pipe Curtain Rods With Nickel Plated Brackets , Providing And Applying White Cement Based Putty , Finishing Walls With Acrylic Smooth Exterior Paint , False Ceiling At All Height , Painting With Synthetic Enamel Paint , Wall Face Unplasticised Rigid Pvc Rain Water Pipes , Moulded Unplasticised Rigid Pvc Rain Water Pipes , Rigid Pvc Rain Water Pipes , Cpvc Pipes , Cpvc Pipes Having Thermal Stability , Stainless Steel Kitchen Sink , Polyethylene Water Storage Tank , Ball Valve Brass Of 25 Mm Nominal Bore , Pvc Nahani Trap Of Heavy Quality , C.P. Brass Long Body Bib Cock , Gun Metal Non Return Valve , Wiring For Light Point Fan Point Exhaust Fan Point , Gi Box With Modular Plate , Gi Box Wih Modular Plate , 3 Pin 5 A Ceiling Rose Bulb Holder , Wiring For Light Power Plug , Wiring For Circuit Submain Wiring , 2 X 6 Sq. Mm Plus 1 X 6 Sq. Mm Earth Wire , 9W B22 Led White L , 24Watt Led Batten Tube Light , 300Mm High Speed 12 Inches Air Exhaust Fan , Single Pole And Neutral Sheet Steel Mcb , C Curve Miniature Circuit Breaker , 5 A To 32 A Rating Miniature Circuit Breaker , Double Pole 240 V Rccb , 3.5 Core Aluminium Armoured Cable , Supply And Termination Of Cable Lugs , 25 Mm X 5 Mm Copper Strip Total Quantity : 3678
Contract Date: Ref. Documents Contract Value : 18.09 Lakh
Government Departments No of Bidders 4
Uttar Pradesh View Result →
Contract Date: Jun 18, 2026 Contract Value : 40.42 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Maharashtra View Result →
Contract Date: Jun 18, 2026 Contract Value : 40.64 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
Maharashtra View Result →
44.
Agriculture #10988522 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In, All Kinds Of Soil , Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.M20 Grade Nominal Mix / Design Mix , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Columns, Pillars, Posts And Struts Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786)Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Brick Work With Clay Flyash F.P.S. Brick (Is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And Two Corners Are Free , Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , P & F 1St Qualityheavy Duty Vitrified Polished Digital Tiles On Floor, Skirting And Steps Etc.In Different Sizes (Thickness Minimum 10Mm) With Water Absortion Less Than Or Equal 0.08% And Conforming To Is 15622 Of Approved Make In All Colour And Shade, Laid With 20 Mm Thick Cm 1: 4 Including Grounting The Joints With White Cement And Matching Pigment Etc Complete.Size 600Mm X 600Mm , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Extra For Using Size Above 200X300mm In Glazed Tiles And For Using 400Mm X 400Mm Mat Finished Tiles In Place Of 300Mm X 300Mm Size. Wall Tiles , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Chargeprofile C : , Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). , Providing And Fixing M.S. Sheet 1Mm Thick Single Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge , (A) Window Openable. , (B) Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dark Shade Using Ordinary Cement. , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :12Mm Thick . , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 20Mm Thick . , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Fixed Portion Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Is : 6315 Marked, For Doors Including Cost Of Cutting Floors As Required, Embedding In Floors And Cover Plates With Brass Pivot And Single Piece M.S. With Stainless Steel Cover Plate , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge.(Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.)With Float Glass Panes Of 5.0 Mm Thickness ( Weight Not Less Than 13.50 Kg/Sqm) , Providing And Fixing Expanded Grill Made Of Aluminum As Per Design And Drawing Having Members Section Of Size 7.5Mm X 6.0Mm And Opening Of Size 102Mm X 99Mm To Aluminum Window/Vent With Required Screws, Y And H Aluminium Sec (As Per Drawing) At The Ends And Middle Joints Respectively Complete In All Respect As Per Direction Of Engineer In Charge.Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , Providing And Fixing Curtain Rods Of 1.25 Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs, Etc., Wherever Necessary Complete: 20 Mm , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. , Carriage Of Earth Incloding Loading ,Unloading Without Stacking With Lea Of 5Km , Making Grooves As Per Design In Plaster 10Mm To 20Mm Wide. , Extra For Plastering Done On Moulding Cornices Or Architraves Including Neat Finish To Line And Level: In Two Coats , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated ‘J Or ‘L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified.5.0Mm Thick (Wt. 8.4 Kg./Mtr. Sq.) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Crazy Marble Stone Flooring 20Mm Thick Marble Stone With Black Or Of Specified Colour Topping Including Filling The Gaps With Cement Marble Chips Mix In Proportion Of 4 : 7 (4Cement : 7 White Black Or White Or Black Marble Chips) Size From 1Mm To 4Mm By Volume And Under Layer Of 25Mm Thick Cement Concrete [1:2:4, Graded Stone Aggregate 12.5Mm Nominal Size] Rubbing And Polishing And Cement Slurry Etc. Complete : In Ordinary Cement. , Extra In Marble/Other Flooring Work For Upto 50 Mm Wide Strip Of Green/White/ Jaisalmer Stone In Flooring Work As Per Direction Of Engineer In Charge , Providing & Fixing Precast Cement Concrete Coping 1 : 2 : 4 Mix 50Mm Thick Complete As Per Specification : , Renewing Glass Panes,With Putty And Nails Wherever Necessary Float Glass Panes Of Thickness 5 Mm , Filling Of Sunk Portion Of Roof With Earthen Pots Of Required Height Including Filling Voids With 1:3:6 Light Concrete, Using Brick Bats Complete Levelling And Dressing The Surface By 50Mm Thick Cement Concrete 1:2:4 As Per Specification. , Supply And Fixing In Cement Mortar Welded Hand Railing Made Out Of Ms Round Or Square Bars, Flats Etc. For Staircase Or Verandah As Per Design Complete In All Respect (Wooden Or Pvc Hand Railing To Be Paid Extra) With Priming Coat Of Red Oxide. , Extra For Providing D Type Pipe Head As Top Of Hand Railing , Providing And Fixing Almirah Lock (50 To 70 Mm Size )Of Approved Make Without Pair Of Handles For Door With Necessary Screws Etc Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Grade 304 , Lettering With Black Japan Paint Of Approved Brand And Manufacture. , Construction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layers With Tractor Mount Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Smooth Wheel Roller To Achieve The Desired Density, Complete As Per Morth Specification Clause 401..For Grading Iii Material , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 5.00Km As Per Morth Specification Clause 305.3 , Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mixer (Pug Mill), Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers In Sub-Base/Base Course On A Well Prepared Sub-Base And Compacting With Smooth Wheel Roller Of 80 To 100Kn Weight To Achieve The Desired Density Including Lighting, Barricading And Maintenance Of Diversion, Etc As Per Tables 400-12 & 400-13 And Morth Specification Clause 406.By Mechanical Means With All Lead , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 80 Mm As Per Drawings And As Per Is 15658:2006.And All Materials Shall Conform To Morth Specification Clause 602.With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blockscategory B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Dia. Nominal Bore. , Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 200Mm Dia. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. 200Mm Normianl Bore , Supply Of Erw M.S. Black Casing Pipe Isi Marked Is:4270/ 1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 200Mm Normianl Bore , Development Of Tube Well As Per Is Specification Using Suitable Compressor To Give Sand Free Water For Required Yield Of The Gravel Packed Tube Well. , S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size:200Mm Dia. , S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete :Solid Pvc (Is 2548 Marked) Grade-I Black For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend And Superior Internal Fittings As Per Is : 7231 . , P & F Flush Pipe Of Approved Make With Complete Fittings For High Level Flushing Cistern: Pvc Exposed (Heavy) 32Mm. , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : , Size 580 Mm X 450 Mm , Size 630 Mm X 500 Mm Dia For Counter Top , P & F Bevelled Edge Mirror/Mirror With Teak Wood Lipping Around Of Special Glass Of Approved Make As Per Direction Of Engineer-In-Charge Complete With 6Mm Thick Commercial Ply Base Fixed To Wooden Screws & Washers. Size 600 X 450Mm X 4 Mm Thick , P & F Towel Rail Or Ring Of Approved Quality/Make: , C.P. Brass Towel Rail Elbow Type With Concealed Screws Size 450Mm (Heavy Duty). , P & F Grating Of Approved Quality/Make: , Stainless Steel Sheet Size 125Mm Dia. , P & F Liquid Soap Container With Brackets Complete Of Approved Make: , P & F Jet Spray For Water Closet With C.P. Copper Tube Flange Of Approved Make. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Making Connection Of G.I. Distribution Branch With G.I. Main Including All Fitting. , Upto 25Mm Dia , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: , C.P. Brass Bib Cock,15Mm Nominal Bore. , C.P. Brass Bib Cock Long Body, 15Mm Nominal Bore Weight Not Less Than 690 Gm , P & F Ball Cock (Is :1703 Mark) With Rod & P.V.C. Ball Complete : Brass Wt. Not Less Than 300 Gm,15Mm. , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make : Pvc Pipe With C.P. Brass Nuts Upto Length 450Mm. , P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make : , Gun-Metal 15Mm Nominal Bore. , Gun-Metal 25Mm Nominal Bore. , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 1000 Litres Capacity , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia , P & F S.W. Master Trap (Inter-Cepting) A Grade (I.S.: 651 Marked) Of Approved Quality/Make 150Mm Dia , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: 110Mm Dia , Coupler (Socket) , Plain Tee , Bend 45 , Vent Cowel , Pipe Clip , Multi Floor Trap , Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade cement concrete Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead. Depth Up To 0.5 M , Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick cement concrete 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr. -Do- Size 600 X 450Mm Depth Upto 0.5 M Cement Cover With Frame. , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Construction Of Recharge Shaft In Filter Pit Including Earth Work Excavation , Lifting Excavted Earth With All Lift And 50 M Lead And Centering & Shuttering Evenever Required.Diameter 900 Mm , Supply & Fixing Pre-Cast Reinforced Cement Concrete Rinngs At The Mouth Of Recharge Shaft Of M20 Mix With 40 Mm Thicknessdiameter 900 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In All Kinds Of Soil , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :20Mm Thick . , Finishing With Neat Cement (Punning). , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix. , Add Extra For Providing Richer Mixes Respectively At All Floor Levels, Providing M-25 Grade Concrete By Using Min 410 Kg Of Cement Per Cum Instead Of M-20 Grade Design Mix. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting (Height Upto 10 M) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , Inside Size 600X450mm Upto Depth Of 0.5M & 38Kg Ci Cover With Frame , 250Mm Dia Internal. , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii(4 Kg. /Cm.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant, 160Mm Dia. , 250Mm Dia S.W. Pipe. , P & F 60 Cm. Wide M.S. Ladder In Open Well Made Of Flat Iron 32X5mm And 10Mm Dia Bars @ 200Mm C/C With Angle Iron Hold Fasts At Suitable Interval Complete As Per Drawing. , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Nominal Bore , P & F G.I. Pipes (Internal Work) With G.I. Fittings (Is:1239-1992 Mark) & M.S. Clamps Including Cutting And Making Good The Walls And Floors : Exposed On Wall, 15 Mm Dia Nominal Bore. B - Class. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. , Size 9 To 12 Mm , Size 3 To 5 Mm , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of Twin Control Light Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 2 Nos Hot Dipped Galvanized M.S Modular Box Of 1.2 Mm Thick With Earth Terminal,2 Nos10 A Two Way Modular Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector ,Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr..) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , On Board , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , S&F Following Sizes (Dia.) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Mm , 32 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 2X 1.5 Sq.Mm , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , 4 X 10.0 Sq.Mm , 4 X 16.0 Sq.Mm , Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Providing & Fixing Of Wiring Accessories Oem Fabricated Following Size Gi Box Of 1.2 Mm Thick With Earthing Terminal And Adjustable Floating Clamp In Recess/ Surface Suitable For Modular Accessories As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1/2 Module , Providing & Fixing Of Following Size Mounting Grid Plates With Cover Plates Made From Fire Retardent Uv Established High Performance Engineering Plastic Suitable For All Universal Metal Boxes For Front Installation & Removal Direct Fit Type Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1-2 Module , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Single Pole Mcb (With B/C Curve Tripping Characteristics) , 6 A To 32 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box , 6 Way , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For Mcb / Rccb And Sp / Tp Mcb As Outgoing ,Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door (For Double Door Db Only ) Complete With Insulated 100 A Rating Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Double Door Ik-09 & Ip-43 With Metal End Box , 6 Way(8+18) , Providing & Fixing Of 240/415 V Isolator Isi Marked Is:13947-Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Four Pole Isolator , 80 A/ 100 A Rating , Triple Pole Isolator , 63A Rating , Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Amp. 2 Module Motor Starter With On / Off Push Button , Blanking Plate , Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 5 Step Fan Regulator 2 Module 360 Dgree Rotating , Providing & Fixing Of Modular Type Switch/ Bell Push Duly Isi Marked (Is :3854) With Cm/L No. Printed And Made Out Of Unbreakable And Fire Retardant Vergin Uv Stabilized Polycarbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating ,Minimum Width Of Switch Toggle( Push Part ) Should Not Less Then 20Mm, Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 10 A Bell Push , Providing & Fixing Of Ding Dong/Musical Chime Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply Installation Testing and Commissioning of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Improvement =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , 3 Pole Mccb With Thermal Magnetic Release , Up To 100 annual periodical maintenance , 25 Ka, Adjustable O/L & Adjustable S/C Setting, , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 35.0 Sq. Mm , 3.5 Core , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Supplying And Making End Termination With Heavy Aluminium Lugs ( Pin / Ring Type ) Confirming To Is 8309 -1993 & Is 8337-1976 Duly Crimped With Crimping Tool, Pvc Tape Etc Of Following Size.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 35.0 Sq.Mm , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 50 Mm , Labour Charges For Excavating Trenches Of Required Width For Pipes Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr.: , All Kind Of Soils , Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor ,Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 300 Mm Sweep , P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Reqd. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Up To 380 Mm Size , Providing & Fixing Of Energy Efficient Direct Fit (Retrofit) Polycarbonate/ Glass Housing Smd Mid Power Led Tube Rod (With Integral Driver & Alumn. Heat Sink ), On Existing Fixture. System Lumen Efficacy ≥ 100 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv ,Thd 20% ,P.F.≥0.95,Cri 80 , Life Time Of Minimum 35000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80)Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200Mm , Min. Lumens Output 2000 Lm Led Tube Rod With Polycarbonate Housing , Providing & Fixing Of Ip20, 2X2 Led Surface/ Recessed Mounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/External Surge Protection Bis Certified Isolated Driver Having Efficiency 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 10 % , P.F.≥0.95,Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Moutning , Minimum Lumen Output 3600 Lm , Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Mounting (With Extruded Alumn. Housing ) , Minimum Lumen Output 1300 Lm , Minimum Lumen Output 1950 Lm , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached. , 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Led Street Light Fixture With Minimum Lumen Output 12500 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 32 Mm Dia. , Supply Installation Testing and Commissioning of Mnre Approved & Confirming To Is:12933 P-1,2,3 & 5 Flat Plate Collector Type Solar Hot Water System Having Collector With Zincalum Sheet Outer Body , Glass - Line / Titanium Enamel Coated Inner Tank With Metal Rust Proof Puf Insulated Body Including Electrical Back Up, Thermostat, Powder Coated / Hot Dipped Galvanized Ms Stand For Collector & Tank Etc. As Required. Of Following Capacity Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 250 Litre/ Day , Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 4 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1.5 Tr Iseer Not Less Then 3.8 , Supply Installation Testing and Commissioning of Monoblock Motor Pump Set Isi Marked (Is:9079-2002) With Tefc Motor, Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011. With Stainless Steel Impellor, Stainless Steel Shaft, Mechanical Seal, Single/Three Phase ( 240 - 440 V ) Permanent Split Capacitor Type (Psc), Fitted With Thermal Overload Protection, Including Cost Of Hardware Etc On Existing Platform Complete. Pump Shall Have Following Hp Rating, Phase, Head, Minimum Discharge Respectively Complete In All Respect. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 2.0 Hp, 3-Ø, (6-27)Mtr, (425-100) Lpm , Supply Installation Testing and Commissioning of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , For Single Phase Submersible / Monoblock Pump , 2.0 Hp To 3.0 Hp (Dol Starter)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
45.
Public Administrative Department #10955866 Price Bid
YEARLY TENDER FOR CIVIL WORK AT VADGON NAGARPANCHYAT VADGAON MAVAL-2 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 m.) by Mechanical Means. 3 Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 to 3.0 m.) by Manual Means. 4 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts complete. 5 Providing drytraprubble stone soling 15cm to 20cm thick including hand packing and compacting complete. 6 Providing second class Burnt Brick masonry with conventional /I. S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls /in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering complete. 7 Providing second class Burnt Brick masonry with conventional / I. S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding complete. 8 Providing and laying Cast in situ/ Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade). 9 Providing internal cement plaster 12 mm. thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 10 Providing fine cement finish 1.5 milimetre thick over green plaster surface including scaffolding curing etc. complete. 11 Providing and fixing in position TMT FE -500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 12 Conveying materials obtained from road cutting including all lifts, laying in layers of 20 cm. to 30 cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than97% of standard proctor density for a lead of over 50 m to 300 m. inclusive from the site of excavation to the site of deposition as directed. 13 Providing and fixing mild steel grill work for windows, ventilators, etc.15 kg/sq.m as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. 14 Providing and errecting chain link fencing 1.6 metre height with galvanised iron chain link of size 50 x 50 milimetre 8 guage thick and fixed 75 milimetre above Ground level on verticalMild Steel Angle of 40x40x6 milimetre size including excavating pits for foundation and embeded in cement concrete block of 1:4:8 mix of size 450x450x670 milimetre at 1.75 metre center to center with iron bar 16 milimetrediameteras hold fast including welding link with angle frame at 30 cm. c/c nuts and bolts and horizontal Mild Steel Angles at top and bottom of 25x25x5 metre size and vertical Mild Steel flat 35 x 5 metre and 25 x 5 metre horizontal including cross support of 40x40x6 metre Angles both sides at every corner or bends embeded in concrete blocks of 1:4:8 of size 450x450x670 milimetre including 3 coats of oil painting etc. complete. 15 Providing and laying concrete pipe ofIndian Standard Non Pressure class of300 milimetrediameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 16 Providing & constructing Brick Masonry Inspection Chamber 60 cm x 45 cm x 90 cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half roundGlazedStone Ware pipes, Brick Masonry, plastering from inside and airtight C. I.cover of 75 Kg with lid and frame fixed in cement concrete etc. complete. 17 Providing & constructing Brick Masonry Inspection Chamber 60 cm x 45 cm x 90 cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round GlazedStone Warepipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. cover medium duty 140 kilogram with frame etc. complete. 18 Providing hard murum side shoulder including supplying hard murum at the road site, including spreading and compacting for sidewidth layers on each side with power roller including artificial watering etc complete. 19 Providing and fixing hume pipe septic tank 900 mmdiameter with vent pipe and cap including necessary (excluding excavation and laying). 20 Providing uncoursed rubble masonary oftrap stones in cement mortar 1:6 in foundations and plinth of inner walls/in plinth of external walls including bailing out water manually, striking joints on exposed faces and watering complete. 21 Providing uncoursed rubble masonary oftrapstones in cement mortar 1:6 in superstructure including raking out joints when plastering is to be done/striking joints when no plastering is to be done watering and scaffolding complete. 22 Providing and applying white-wash in two coats on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing & brooming down complete. 23 Providing and applying colour-wash of approved colour and shade in two coats to new surface including scaffolding, brushing and brooming down (excluding base coat of white-wash) etc. complete. 24 Providing and applying washable powder distemper of approved colour and shade to old & new surfaces in one coat including scaffolding, preparing the surfaces (excluding the priming coat.) complete. 25 Providing & applying washable oil-bound distemper of approved colour and shade to old & new surfaces in one coat including scaffolding, preparing the surfaces. (excluding the primer coat) complete. 26 Providing and applying interior wall finish luster of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean. Applying Asian/ Berger/ Nerolac/ Duuex Paints or equivalent wall primer with brushwith mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. Applying Asian/ Berger/ Nerolac/ Dulex Paints or equivalent Acrylic wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent interior wall finish luster 1st coat with brush/ rubber/ spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat of Asian / Berger / Nerolac / Dulux Paints or equivalent interior wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity (With prior approval of S.E.). 27 Providing & applying two coats of lead/ zinc base oil paint/ bituminious paint of approved colour to new structural steel work and iron work in buildings including scaffolding if necessary, cleaning and preparing the surface etc.complete.(excluding primer coat). 28 Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to old plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. 29 Providing and laying rough Shahabad Stone flooring 25 mm to 30 mmthick & of required width in plain/ diamond pattern on a bed of 1:6 C.M. includingcement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc.complete 30 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 31 Providing and laying polished Kotah stone flooring 25mm to 30mm thick & of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete. 32 Providing and laying cement concrete 50 mm. thick with M-15 cement concrete laid to proper level and slope in alternate bays including compaction filling joints, marking lines to give the appearance of tiles of 30 cm. x 30 cm. or other size laiddiameter gonally/square etc finishing smooth (with extra cement) in any colour as directed and curing complete with CrushedSand. 33 Providing and laying polished machine cut machine polished Kotah stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete. 34 Providing sills of Marble other than makrana 20 mm. to 25 mm. thick, on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges and cleaning complete. 35 Providing and fixing black kadappa stone as shelves 25 mm. thick machine polished, extending the polish upto 20 cm. width on lowerside, rounding corners, laying in position jointing with bedding cement mortar 1:4 proportion curing etc. complete. 36 Providing and laying ceramic tiles having size 30 cm. x 30 cm. conforming I.S.15622/2006 (group D II-A) and 7 to 8 mm. thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/ colour cement slurry cleaning curing etc. complete. 37 Providing Mirror polishing to Kota Stone Flooring including using all necessary stones and equipments cleaning, washingetc. complete. 38 Providing and laying vitrified mirror/ glossy finish tiles for Flooringof decorative type having size 590 mm. to 605 mm. x 590 mm. to 605 mm. of 8 to 10 mm. thickness and confirming to I.S. 15622: 2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. 39 Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 60 mm. thickness of having a strength of 300 kg/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm. thick including skirting joints and cleaning etc. complete 40 Providing and fixing plain zinc sheeting of 0.80 milimetre thick (22 B.W.G.) over the ridge hip or velley to galvanised iron sheet roofing including all fastening and bolt galvanised iron screws and bolts and lead and bitumen washers complete. ( Weight of 6.8 kg per Square metre). 41 Providing and fixing 6.00 mm thick I.S.I. mark Asbestos Cement Corrugated sheet roofing including galvanised iron J or L hook bolts galvanised ironand bituminous G.I.washers, galvanised iron clamps, bolts and nuts and scaffolding complete. 42 Providing and fixing 6 mm thick I.S.I. mark Asbestos cement ridge capping for roofing including galvanised iron hooks, bolts, galvanised iron and bituminous washers, galvanised iron clamps, bolts and nuts including scaffolding, complete. 43 Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 120 cm wide withteak wood planking 20 mm thick including two coats of coal-taring the upper surface of plank (excluding painting to under side of plank). 44 Providing and fixing valley gutters of 24 B.W.G. 0.63 mm thick G.I.sheet 120 cm. with 20 mm thick teak wood planking underneath coal tarring etc. complete. 45 Removing and resetting Mangalore tiles from roof including refixing loose battens. 46 Removing G.I or A.C.sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. 47 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 48 Providing and fixing 50 mm. x 50 mm. Mild Steel square pipe framed steel windows of various sizes as per details with welded square bars 12 mm. at 10 cm. center to center without hot dip zinc coating without/ with ventilator including fabrication, glazing with plain/ obscured glass panes of approved type and quality, all fixtures and fastenings and finishing with one coat of primer complete. 49 Providing and fixing M.S. grill door 24 kg/sqm. of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc 50 Providing and fixingPoly Venyl Chloridecoloured Ridge tiles over U Poly Venyl Chlorideroofingwherever required having size 113 cm x 41 cm and height 9.50 cm for ridge including fastening with self drilling screw having washers made ofstainless steel complete. 51 Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm. at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm. at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm. at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm. at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm. at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm. thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. completewith colour Anodising without box. 52 Dismantling stone masonry in lime or cement mortar including stacking the materials as directed with all leads, lifts complete. 53 Providing and fixing solid core flush door shutter in double leaf 32milimetrethick decorative type of exterior grade as per detailed drawings approved face veneers 3milimetrethick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 54 Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts, complete. 55 Dismantling stone masonry in mud including stacking the materials as directed with all leads, lifts complete. 56 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts, complete. 57 Providing and laying cement concrete pipe of I.S. 458:2003 non pressure-3 classof 600 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. 58 Providing and laying in situ/ Ready Mixcement concrete M-20of trap/ granite/quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/ pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). 59 Providing and laying cast in situ/ Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). 60 Providing and laying Cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landingsas per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic ControllerwithSuperwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). 61 Providing and laying Cast in situ/ Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). 62 Providing and laying Cast in situ/ Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). 63 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting, dewatering etc. complete (lift upto 1.5 m)by Mechanical Means. 64 Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 m) by Mechanical Means. 65 Filling in plinth and floors with contractors soil. Sand or murum materials in 15 cm to 20 cm layers including watering & compaction complete. 66 Dismantling the R.C.C. work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed. 67 Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. 68 Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. 69 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm. thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. 70 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted /bolted / welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. 71 Providing and fixing reinforced cement concrete Heavy duty (160 Kg) cover of size 60centimeter x 45centimeterwith frame over inspection chamber etc. complete. 72 Providing and fixing reinforced cement concreteMedium duty (140 Kg) cover of size 60centimeter x 45centimeterwith frame over inspection chamber etc. complete. 73 Providing and fixing reinforced cement concreteMediumduty (100 Kg) cover of size 60 centimeter x 45centimeterwith frame over inspection chamber etc. complete. 74 Providing and laying cement concrete pipe of I.S. 458:2003 non pressure-2 classof 450 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. 75 Providing and laying concrete pipe of I.S. N.P.class of150 mmdiameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 76 Providing and laying concrete pipe of I.S.NP.class of225 mmdiameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 77 Providing and laying concrete pipe of I.S.NP.class of300 mmdiameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. 78 Providing and laying cement concrete pipe of I.S. 458:2003 non pressure-2 classof 800 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. 79 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters. 80 Providing and fixing on walls / ceiling / floor 15 milimetrediameterChlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedcomplete. 81 Providing and laying cement concrete pipe of I.S. 458:2003 non pressure-3 classof1200 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. 82 Providing and laying cement concrete pipe of I.S. 458:2003 non pressure-3 classof1000 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. 83 Providing and laying cement concrete pipe of I.S. 458:2003 non pressure-3 classof900 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. 84 Providing and laying cement concrete pipe of I.S. 458:2003 non pressure-3 classof 800 milimetrediameterin proper line, level and slope including providingandfixing collars in cement mortar 1:2 complete. 85 Providing and applying two coats of lead/ zinc base oil paint/bituminous paint of approved colour and shade to new wood work and fiber boards including preparing the surface, knotting, scaffolding if necessary, excluding primer coat etc. complete. 86 Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or velley to galvanised iron sheet roofing including all fastening and bolt galvanised iron screws and bolts and lead and bitumen washers complete. ( Weight of 6.8 Kg/Sq.m.) 87 Providing and fixing corrugated galvanised iron sheets of 0.63 mm thickness (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screw and bolts and lead and bitumen washers as per drawing complete (weight of 5.5 kg per Sqm.) 88 Providing and applying one coat of lead/ zinc base oil paint/ bituminous paint of approved colour and shade to old wood work previously painted and fiber boards including if necessary scaffolding, preparing surface excluding primer coat etc. complete. 89 Scrapping the old plastered internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding etc. complete as directed. 90 Washing and cleaning of decorated wall surfaces with soap, soda and water etc. complete. 91 Providing and applying plastic emulsion paint of approved quality, colour and shade to old/ new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat) complete. 92 Providing and laying225 mmdiameter half round salt glazed stoneware pipe including fitings such as bends, tees, single junction,double junctions laying jionting (including excavation and refilling the trenches) complete 93 ProvidingandlayinginsitucementconcreteM-30withtremixtreatmentfor200mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groovecuttingof4mmwideand20mmdeepwithnecessaryrefillingwithbitumen( excluding reinforcement) with coarse and fine aggregate ( VSI grade finely washed crushed sand) etc. complete 94 Providing and laying in situ / ready mix M20 CC of trap/ granite/ quartzite/ gneiss metal for wearing course 8cm thick including compacting, finishing, curing andfilling in joints with bitumenetc.complete.(withfullyautomaticmicroprocessorbasedPLCwithSCADA enabled concrete batch mix plant / pan mixer with fine agreegates of required specifications ( VSI sand finely washed etc ) 95 Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre asperdrawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Maharashtra View Result →
46.
Housing Urban and Rular Development #10911426 Price Bid
Tender for Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1 :6:12 (1 Cement: 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With : Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , Coursed Rubble Masonry With Hard Stone (First Or Second Sort) In Superstructure Above Plinth Level And Upto Floor Five Level. , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note: Butt Hinges And Necessary Screws Shall Be Paid Separately)Second Class Teak Wood 35 Mm Thick Shutters , Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes (Weight Not Less Than 1 0 Kg Per Sqm) Fixing With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. 9.9.1 Second Class Teak Wood 9.9.1.1: 35 Mm Thick , French Spirit Polishing Two Or More Coats On New Works Including A Coat Of Wood Filler , Providing And Fixing Isi Marked Aluminium Butt Hinges Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete: 125X75x4 Mm , Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300X16 Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete: 300X10 Mm , Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. Single Rubber Stopper , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1 :4 (1 Cement: 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 1000X1000 Mm , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Marble Stone Flooring With 18 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Cement Mortar 1 :4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Grey Cement Slurry, Including Rubbing And Polishing Complete With : Makrana White Second Quality , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement: 4 Coarse Sand): 25 Mm Thick , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Fine Sand) , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 15 Mm Cement Plaster 1:2 (1 Cement : 2 Stone Dust) On The Rough Side Of Single Or Half Brick Wall. , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade: New Work (Two Or More Coats Applied @ 1.43 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm) , 25 Mm Wooden Planking, Tongued And Grooved In Flooring, Including Fixing With Iron Screws Complete With: Second Class Teak Wood , Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg I M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm)@ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 25 Mm Thick , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/10 Sqm Of Approved Brand And Manufacture , Providing And Laying Six Courses Water Proofing Treatment With Bitumen Felt Over Roofs Consisting Of First, Third And Fifth Course Of Blown Bitumen 85/25 Or 90/15 Conforming To Is : 702 Applied Hot @ 1.45, 1.20 And 1.45 Kg Per Square Metre Of Area Respectively, Second And Fourth Courses Of Roofing Felt Type 3 Grade I Conforming To Is : 1322 (Hessian Based Self Finished Bitumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Including Preparation Of Surface But Excluding Grading, Complete. , Providing Corrugated G.S. Sheet Roofing Including Vertical I Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces), Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/M2 , Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Dia G.I. Limpet And Bitumen Washers Complete. 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm/M2 , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge.Concealed Work, Including Cutting Chases And Making Good The Walls Etc. 15 Mm Nominal Outer Dia Pipes , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , 32 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. External Work 50 Mm Nominal Outer Dia .Pipes. , 80 Mm Nominal Outer Dia .Pipes. , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm Dia Cp Brass Single Hole Basin Mixer Of Approved Quality And Make, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:- White Vitreous China Wash Basin Size 550X400 Mm With A 15 Mm Cp Brass Single Hole Basin Mixer , Providing And Fixing Cp Brass 32Mm Size Bottle Trap Of Approved Quality & Make And As Per The Direction Of Engineer-In-Charge. , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 : 15 Mm Nominal Bore. , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is:8931. 15 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design:180X150 Mm Size P Type. With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Masonry Chamber 60X60x75 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.I. Surface Box 100Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design :With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5 , Providing And Laying Cement Concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) All-Round S.W. Pipes Including Bed Concrete As Per Standard Design : 250 Mm Diameter S.W. Pipe 100 Mm Diameter S.W. Pipe , 250 Mm Diameter S.W. Pipe , Providing And Fixing Toilet Paper Holder :C.P. Brass , Providing And Fixing 100 Mm Sand Cast Iron Grating For Gully Trap. , Cement Fibre Boards , Lgfs System , Oriental Standard Boards , Gypsum Board 12Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
47.
Housing Urban and Rular Development #10908306 AOC
Providing Basic Amenities And Beautification Of Dargoba Temple Campus, At-Dargoba Mandir, Pare, Tal-Khanapur, Dist-Sangli.-Cubic Metre Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means Cubic Metre Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (upto all leads and lifts) By Mechanical Means Cubic Metre Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer excetra complete. With fine aggregate (Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND). Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer excetra complete. with fine aggregate (Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Providing expansion joints in reinforced cement concrete framed structure (exterior column) with plain premoulded filler 25 milimetre thick with 75 milimetre wide and 1 milimetre thick stainless steel plate and finishing, excetra complete. (For Ground Floor) Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixe excetra complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer excetra complete.With fine aggregate (Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer excetra complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) (For Ground Floor) using ARTIFICIAL SAND). Providing and laying in situ M-25 cement concrete of trap / granite / quartzite / gneiss metal with 15 percent plum of trap stones for retaining walls and jetty, excetra including necessary formwork, compacting, curing, bailing out water manually in tidal range, excetra complete. Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. For Ground Floor) Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water, striking joints on unexposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Providing and fixing mild steel grill railing weighing 20 kilogram per square metre with polyvinyl chloride handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing polyvinyl chloride handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, excetra complete. (For Ground Floor) Providing soling using 80 milimetre size trap metal in 15 centimetre layer including filling voids with crushed sand / grit, ramming, watering, excetra complete. Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In- Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. Providing coursed rubble masonry first sort of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in superstructure including racking out joints on the inside when plastering is to be done, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing and laying rubble stone flooring laid in cement mortar 1:3 as per drawing and technical specifications, excetra complete. (using ARTIFICIAL SAND). Providing sills of granite 20 milimetre to 25 milimetre thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 milimetre to 450 milimetre section as per Indian Standard : 4923 YST 310 grade produced from iron ore and blast furnace route, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and painting complete. (For Ground Floor) 124610.70 Providing and fixing in position guard railing as per Drawing Number 15 type C dated 20-4-1979, with three rows of 40 milimetre diameter galvanised iron pipe 30 centimetre apart and fixed in mild steel channels of section 100 milimetre X 50 milimetre X 6 milimetre spaced 2.5 metre center to centre, 1:2:4 cement concrete bedding of size 45 centimetre X 30 centimetre X 30 centimetre as per detailed drawing, with 3 coats of approved yellow and black paint including necessary excavation in any strata. Providing leather finished polishing to granite stone slab by continuous grinding in four coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing, excetra complete. (For Ground Floor) Providing and applying priming coat over new / old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matters and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding, excetra complete. (For Ground Floor) Providing and applying two coats of lead / zinc base oil paint / bituminious paint of approved colour to new structural steel work and iron work in buildings including scaffolding if necessary, cleaning and preparing the surface, excetra complete. (excluding primer coat). (For Ground Floor) Providing and laying in situ cement concrete M-30 with tremix treatment for 200 milimetre thickness for flooring with groove cutting of 4 milimetre wide 20 milimetre deep with necessary refilling with bitumen, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing and fixing auto closing pillar cock of pressmatic tap of approved make including all fixtures, fittings, excetra complete. (For Ground Floor) Providing and fixing 450 milimetre X 550 milimetre size superior type belgium mirror with 16 milimetre diameter nickel plated towel rod, excetra complete. (For Ground Floor) Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer excetra complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Providing and fixing 15 milimetre diameter ball cock medium type with polyvinyl chloride float including sockets and necessary fittings and tested as per municipal requirements, excetra complete. (For Ground Floor) Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For Ground Floor) Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor) Providing and fixing in position (as per Indian Standard 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts excetra complete. - With colour anodising without box. (For Ground Floor) Providing and fixing 30 milimetre thick polyvinyl chloride flush L door shutter consisting of panel of hollow polyvinyl chloride profile of 20 milimetre thickness consisting frame made out of mild steel tubes of 19 gauge thickness and size of 19 milimetre X 19 milimetre inserted inside the hollow section of stiles rails top and bottom rails and two milimetre X 19 milimetre mild steel tubes inserted horizontally inside the hollow profile section using 4/5 milimetre sheet using screws hollow profile shall be lipped with 10 milimetre (5 milimetre X 2) thick X 20 milimetre width on stiles and rails using solvent cement. The inner panel shall be laminated with 5 milimetre thick termite proof waterproof plain / prelam poly vinyl chloride sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening excetra Complete as per direction of Engineer in-charge, manufacturer’s specification and drawing. (For Ground Floor) Providing and fixing Orissa type colour glazed earthenware 625 milimetre X 450 milimetre water closet including trap, cast iron soil and vent pipe upto the out side face of wall including 100 milimetre diameter cast iron plug bend, 15 milimetre thick 10 litre polyvinyl chloride flushing cistern with all necessary pipe connection, excetra complete. (For Ground Floor) Providing and fixing oval type under counter wash hand basin of 16 inch X 22 inch size and of special colour shed having telephonic black / colour granite of 18 milimetre thick fixed on black kadapaa frame work, including cromium plated coupling, bottle-trap using approved make oval type wash basin as per detailed drawing or as directed by Engineer In-charge, excetra complete. (For Ground Floor) Providing and fixing 15 milimetre diameter screw down bib / stop tap of brass including necessary socket union nut complete. (For Ground Floor) Providing and fixing Ivory glazed earthenware full stall type urinal with poly vinyl chloride flushing cistern of 5 litres capacity with fitting inlet pipes and stop tap brackets for fixing the cistern 32 milimetre diameter poly vinyl chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection upto the outside face of the wall. (For Ground Floor) Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, excetra complete. Providing first class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 including scaffolding, racking joints pointing in cement mortar 1:3 and watering in pillars of rectangular or square shape as shown on the drawing or as directed, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing and laying damp proof course 50 milimetre thick in M-20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete. Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25- 30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturers product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For Ground Floor) Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:5 with neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) Providing and applying two coats Apex Ultima Puranature Anti- Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, excetra) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Providing and applying plastic emulsion paint of approved quality, colour and shade to new surfaces in three coats including scaffolding, preparing the surfaces (excluding primer coat), excetra complete. Providing and fixing Indian teak wood eaves boards 15 centimetre wide and 25 milimetre thick plain decorative type including scaffolding and painting with two coats, excetra complete. (For Ground Floor) Providing and laying cast in situ / Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete arches with skew backs as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block). Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed)With fine aggregate ( Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Providing and laying rough shahabad stone flooring 50 milimetre to 60 milimetre thick and of required width in plain / diamond pattern on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For Ground Floor) Providing and applying spray plaster made with finelly graded marble and quartz in 2 milimetre thickness in two coats using putty knife or trowel to newly plaster fairly even surface after minimum 30 days gap, in all positions including finishing the surface using zero number sand paper or fine emry paper gently level the area by moving paper in round circles removing the dust and clean the surface with dry cloth and scaffolding including all materials and labour, excetra complete. (For Ground Floor) Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing groove to required size at specified location as directed by Engineer, at junction of brick masonary wall and reinforced cement concrete beams or column, at junction of composite masonary, including scaffolding, finishing curing, excetra complete. Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For Ground Floor) Providing and fixing false ceilling of plain asbestos cement sheets 4 milimetre thick with teak wood beadings 45 milimetre X 12 milimetre thick frame work of counrtry teak wood battens of size 70 milimetre X 60 milimetre at 1.00 metre center to center including scaffolding, if necessary, all iron work and painting (visible surfaces) to asbestos cement sheet and beading in two coats, excetra complete. excluding teak wood runner to be paid seperately). (For Ground Floor) Providing and laying in position flooring of telephone black amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) using ARTIFICIAL SAND). Providing and preparing kitchen otta up to 75 centimetre width, made up from 30 milimetre thick and 75 centimetre high vertical support for Kadappa at one metre center to center of 25 milimetre thick both side polished Kadappa middle shelf and bottom of 20 milimetre thick one side polished Kadappa with facia patti of 20 milimetre X 50 milimetre Kadappa including all material, labour, cutting, fixing with cement mortar and araldite, all material labour cutting fixing with cement mortar and araldite curing polished and cleaning excetra complete. (For Ground Floor) Providing and fixing on walls / celling / floor, 15 milimetre diameter chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) Providing and fixing on walls / celling / floor, 25 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) Providing and laying in trenches 15 milimetre diameter chlorinated poly vinyl chloride pipe including necessary excavation, fittings, refilling trenches, excetra complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. Providing and laying ceramic tiles of having sizes 30 centimetre X 45 centimetre and confirming corrosponding Indian standared for dado and skirting required position with ready made adhesive mortar approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets union nut complete. (For Ground Floor) Providing and fixing 10 centimetre cast iron nahani trap including cast iron grating, bend and piece of cast iron pipe upto the outside face of the wall complete. (For Ground Floor) Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at one kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre X 300 milimetre, making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For Ground Floor) Providing and fixing poly vinyl chloride rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 milimetre to 2.7 milimetre confirming to Indian Standard : 13592-1992 including proper rain water receiving recess with poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40 milimetre from face of wall affixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge excetra complete. (For Ground Floor) Total-A Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.) Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune. Standard Consistancy, Fineness, Specific Gravity, Setting Time (Initial and Final), Compressive Strength, Soundness Test for Cement Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Artificial Sand Compressive Strength of Cement Concrete Cube Sieve Analysis Test for Metal below 40 milimetre Water Absorption, Specific Gravity, Impact Value, Crushing Value Test for Metal below 40 milimetre Flekiness & Elongation Test for Metal below 40 milimetre Concrete Mix Design (with all tests on basic materials) for Grade M-25 Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks Compressive Strength of Cement Mortar Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Sand Crushing Value / Compressive Strength, Water Absorption, Specific Gravity Test for Stone / Rubble Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar upto 16 milimetre) Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar above 16 milimetre) Liquid Limit & Plastic Limit for Plinth Filling Soil/Murum Compaction test (Proctor Density) Soil/Murum Compaction test Density by Sand Replacement Method Concrete Mix Design (with all tests on basic materials) for Grade M-30 Thickness, Mass per Running Metre of Aluminium Section Water Absorption, Modulus of Rupture Test for Ceramic / Vitrified Tiles Water Absorption, Modulus of Rupture Test for Natural stone/Kota/Marble/Granite/Tandoor etc) Wood density ,Moisture content Test Total B Total A+B
Contract Date: Apr 29, 2026 Contract Value : 2.65 Crore
Government Departments No of Bidders 1
Maharashtra View Result →
48.
Power #10907633 AOC
Construction Of New Test Lab Building At 33/11 Kv Sub Centre, Fatehabad And Other Related Civil Works. - Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(DSR 2.8) All kinds of soil. (DSR 2.8.1) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR )(DSR 2.25) 5 Excavating, supplying, stacking and filling of local earth (excluding royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. NSI Based on(DSR 2.25(a)) 6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26) All kinds of soil (DSR 2.26.1) 7 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (DSR 2.28) All kinds of soil (DSR 2.28.1) 8 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. (DSR 2.3) All kinds of soil (DSR 2.30.1) 9 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.31) 10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2) 11 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.3) 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) 13 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.2.2) 14 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3) 15 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) 16 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) (DSR ) (DSR 4.10) 17 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. (DSR )(DSR 4.12) 18 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) 19 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (DSR 5.2) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2) 20 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.3) 21 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) 22 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4) 23 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5) 24 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) 25 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7) 26 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15) 27 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1) 28 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19) 29 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.12) 30 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.13) 31 Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR )(DSR 5.15) 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)/ (DSR 5.22A.6) 33 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) 34 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) 35 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) 36 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) 37 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (DSR 6.13) Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) 38 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab upto 0.50 sqm (DSR 8.2.1.1) 39 (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2) 40 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2) 41 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. (DSR )(DSR 8.4) 42 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR )(DSR 8.5) 43 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. (DSR )(DSR 8.6) 44 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : (DSR 8.14) Red sand stone - exposed face fine dressed with rough backing. 8.14.1 30 mm thick (DSR 8.14.1.5) 45 Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : (DSR 8.28) Decorative veneer facings of approved manufacture (DSR 8.28.1) 46 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 18 mm thick (DSR 8.30.1) 47 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 25 mm thick (DSR 8.30.2) 48 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 8.31) 49 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (DSR 9.1) Sal wood (DSR 9.1.2) 50 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 35 mm thick shutters (DSR 9.5.1.1) 51 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 30 mm thick shutters (DSR 9.5.1.2) 52 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (DSR 9.7) Second class teak wood (DSR 9.7.1) 53 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 35 mm thick (DSR 9.9.1.1) 54 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 30 mm thick (DSR 9.9.1.2) 55 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR 9.11) 5.0 mm thick(weight not less than 12.50 kg per sqm) instead of 4 mm thick(weight not less than 10 kg per sqm). (DSR 9.11.1) 56 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR )(DSR 9.12) 57 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR )(DSR 9.14) 58 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Panelled or panelled & glazed shutters : 9.16.1 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.1.2) 59 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Glazed shutters : 9.16.2 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.2.2) 60 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 12 mm thick (DSR 9.17.1) 61 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 18 mm thick (DSR 9.17.2) 62 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) 63 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x12 mm (DSR 9.40.2.1) 64 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 25 mm dia (heavy type) (DSR 9.47.2) 65 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to steel windows by welding (DSR 9.48.1) 66 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 125x65x2.12 mm (DSR 9.57.1) 67 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2) 68 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 75x47x1.70 mm (DSR 9.57.3) 69 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2) 70 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 200x10 mm (DSR 9.63.2) 71 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 150x10 mm (DSR 9.63.3) 72 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1) 73 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 100 mm (DSR 9.66.2) 74 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 75 mm (DSR 9.66.3) 75 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.1) 76 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.15.2) 77 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16) Electric resistance or induction butt welded tubes (DSR 10.16.3) 78 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. (DSR )(DSR 10.17) 79 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR )(DSR 10.18) 80 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2) 81 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR )(DSR 10.28) 82 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) 83 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1) 84 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR )(DSR 11.2) 85 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1) 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) 87 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR )(DSR 11.27) 88 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR )(DSR 11.37) 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41) Size of Tile 600x600 mm (DSR 11.41.2) 90 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (DSR 11.48) Size of Tile 600x600 mm (DSR 11.48.2) 91 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR 12.41) 110 mm diameter (DSR 12.41.2) 92 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 75 mm (DSR 12.42.1.1) 93 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 110 mm (DSR 12.42.1.2) 94 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (DSR 11.56) Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent (DSR 11.56.1) 95 Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). (DSR 12.64) 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. (DSR 12.64.1) 96 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1) 97 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:6 (1 cement: 6 coarse sand) (DSR 13.4.2) 98 15 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:4 (1 cement: 4 coarse sand) (DSR 13.5.1) 99 15 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:6 (1 cement: 6 coarse sand) (DSR 13.5.2) 100 12 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2) 101 6 mm cement plaster of mix : (DSR 13.16) 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) 102 Neat cement punning. (DSR )(DSR 13.18) 103 Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. (DSR ) (DSR 13.20) 104 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR )(DSR 13.21) 105 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (DSR 13.41) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre (DSR 13.41.1) 106 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) 107 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR )(DSR 13.80) 108 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour(DSR 13.81) Old work (one or more coats) (DSR 13.81.1) 109 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR )(DSR 13.88) 110 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR )(DSR 13.91) 111 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) 112 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (DSR 13.111.1) 113 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (One or more coat applied @ 0.90 ltr/10 sqm). (DSR 13.111.2) 114 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) 115 Renewal of old putty of glass panes (length) (DSR )(DSR 14.9) 116 Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR )(DSR 14.79) 117 Providing & fixing White vitreous china water closet squatting pan (Indian type) along withS or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2) 118 DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (DSR )(DSR 14.82) 119 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (DSR 15.2) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (DSR 15.2.2) 120 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR )(DSR 15.3) 121 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7) In cement mortar (DSR 15.7.4) 122 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): (DSR 15.8) From brick work in cement mortar (DSR 15.8.3) 123 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area 3 sq. metres and below (DSR 15.12.1) 124 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.19) 125 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : (DSR )(DSR 15.24) 126 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) G.S. Sheet (DSR 15.28.1) 127 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (DSR )(DSR 15.52) 128 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR )(DSR 15.56) 129 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. (DSR )(DSR 15.58) 130 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR )(DSR 15.60) 131 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. (DSR )(DSR 16.42) 132 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. (DSR )(DSR 16.44) 133 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR )(DSR 16.53) 134 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR )(DSR 16.68) 135 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR 16.7) Made of G.I. wire of dia 4 mm (DSR 16.70.1) 136 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR )(DSR 16.75) 137 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. (DSR )(DSR 16.76) 138 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) 139 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1) 140 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) 141 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) 142 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR )(DSR 17.7A) 143 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2) 144 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1) 145 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR )(DSR 17.31) 146 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms (DSR 17.69.1) 147 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2) 148 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3) 149 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 20 mm nominal bore (DSR 18.15.2) 150 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 20 mm nominal bore (DSR 18.16.2) 151 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 25 mm nominal bore (DSR 18.17.1) 152 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore (DSR 18.17.1A) 153 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 32 mm nominal bore. (DSR 18.17.2) 154 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 20 mm nominal bore (DSR 18.21.1.2) 155 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 20 mm nominal bore (DSR 18.21.2.2) 156 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR )(DSR 18.48) 157 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR )(DSR 18.65) 158 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : (DSR 19.5) 100 mm diameter (DSR 19.5.1) 159 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.1.1) 160 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2) 161 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.1.3) 162 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.2.1) 163 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2) 164 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3) 165 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR 21.3.1) 166 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 21.3.2) 167 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (DSR 21.3.3) 168 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With stainless steel cover plate minimum 1.25 mm thickness (DSR 21.4.1) 169 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With brass cover plate minimum 1.25 mm thickness (DSR 21.4.2) 170 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). (DSR )(DSR 21.5) 171 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. (DSR )(DSR 21.6) 172 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (DSR )(DSR 21.18) 173 Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq mm frls pvc insulated copper conductor single core cable in surface /recessed medium class pvc conduit , with modular switch ,modular plate, suitable GI box and earething the pint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR E&M 1.10)Group A (DSR E&M 1.10.1) 174 Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulatted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) 175 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x2.5sq. Mm + 1x2.5 sq. mm eartrh wire (DSR E&M 1.14.2) 176 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x4sq. Mm + 1x4 sq. mm eartrh wire (DSR E&M 1.14.3) 177 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 1.21) 25mm (DSR E&M 1.21.2) 178 Supplying and fixing 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on Surface/recess,complete with tinned copper bus bar, heutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator) (DSR E&M 2022 2.3.1) 179 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) 180 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR E&M 2022 2.12.2) 181 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 2022 5.2) 182 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (DSR E&M 2022 19.1) 183 Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 ) 184 Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (CSI No. 5.20) 185 Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.18) 186 Brick work in Super structure with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.19) 187 S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (CSI No. 9.22) 188 Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia 189 Supply and fixing of power plug with 15A/250 voltflushtype switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mmsize with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 2018 PWD 1139 190 Supply and fixing ofLED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. 2018 PWD 1413(A)CAT AA 191 S/F of LED Bulb 9Watt bajaj or equivalent make as approved sample and make as per direction of Engineer in charge (NSI) 192 S/F of 07 Watt LED bulb Syska or other equivalent make including cost of labour, T&P etc required for proper completion of the work (NSI) 193 Providing and lowering of 32 mm dia. uPVC column pipe Finolex/Ashirwad or equivalent make with column coupling socket etc. including cutting the pipe of required length, proper jointing the same including cost of all materials, labour, T&P etc required for proper completion of work.(NSI) 194 Supply and fixing support clamps for 32mm dia column pipes made out of MS flats, pairs of bolt-nuts etc complete with all material, labour, T&P. (CSI No. 19.24 e) 195 Supply & installation of electrical control panel of L&T / Havells or equivalent make for 1.5/2.00 pump set single phase submersible pump / pumpset containing contractor relay condenser. (CSI No. 19.31b) 196 Supply & Installation of 2.00 HP outlet 40mm dia. or more, Head 89/45, Discharge 2000/6000 LPH submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (CSI No. 19.32c) 197 Supply and fixing of 2.5 mm2 for pump above 1 HP and up to 3 HP submersible cable Havels or equivalent make, for submersible pump complete in all respect. (CSI No. 19.33b) 198 Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (CSI No. 19.34) 199 Mild Steel or Iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof work gates etc. wrought to required form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost when steel is to be provided by the department. (CSI No. 9.02) 200 Supply and fixing CP Nahani Trap India make of heavy approved quality complete with CI grating, including supply of all materials,labour and T&P etc. required for proper completion of the work. (CSI No. 27.21b) as above but for 100 mm.PVC trap. 201 Providing and fixing CI GRATING 100 mm dia including all materials, labour cartage T&P etc.required for proper completion of the work. (CSI No. 27.25) 202 Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI) 203 Providing and fixing 12 mm thick Industrial tiles size 300 x 300 mm or more of Kajaria or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete (NSI) 204 Water proofing treatment over Roof, wall, Chajjas, Balcony etc. with Engineer Plus 7 layer waterproofing system at leakage, seepage area consisting of Surface preparation roughening of surface, opening of cracks in V groove in size of 5 mm to 10 mm width, Back filling of cracks with SBR Latex, 2 layer Spraying Mixture of Aquasil-99 and Aquaprime-99 (Take 20 liter clean water+ 1 liter Engineer Plus Aquasil-99 + 2 liter. Engineer Plus Aquaprime-99 in proportion 20:1:2 This solution should not sprayed over more than 40 sqm area, 3rd Laying 90GSM fiber glass mesh with proper overlap, 4th coat of brushable mortar prepared with Engineer Plus Aquaprime-99, water & cement (Aquaprime -99 @ 0.45 kg per sqm, water @0.45 kg per sqm & cement @0.68 kg per sqm.) in the proportion of 1:1:1.5 by weight, After 4th coat allow the coating to air cure for minimum four hours, after 4 hours interval apply, 2 coat of Flexicoat-99 mixed with Water (Flexicoat-99 @0.33 kg/sqm, water @0.66 Kg per Sqm) in the proportion of 1:2 by weight in 4 hours interval. After 6th coat allow the coating to air cure for minimum 4 hours. After 4 hours interval apply, 7th coat of Engineer Plus smartcoat-99 (Smartcoat-99 @ 0.45 Ltr/sqm & water @ 1.35Ltr/sqm in the proportion of 1:3). The surface will dry within 2 hours and surface would be fully water proof and usable after a period of 24 hours and the final appearance of the coating will be gray/milky white. The rates are included the cost of all chemicals, labours, and Required T&P for Proper completion of Work.
Contract Date: Apr 29, 2026 Contract Value : 36.93 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
49.
Rural Development #10859948 AOC
Tender For Akole Cemetery Improvement, Mulshi Taluka - Excavationforfoundationinearth,soilofalltypes,sand,gravelandsoftmurum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthe buildingareaand stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 2 Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterial upto distanceof50metresbeyondthebuildingareaandstackingandspreadingas directed,dewatering, preparing the bed for the foundation and necessary back filling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto 1.50m)ByMechanical Means 3 Excavation for foundation in Hard rock by blasting including trimming and leveling the bed bychiselingwherenecessaryandremovingtheexcavatedmaterialandstacking itin measurable heaps within a distance of 50 metres from the building area including dewateringand back filling with available earth/murum, watering, ramming, etc. complete.(Liftupto 1.5m) By Mechanical Means 4 Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete. 5 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 6 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 7 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. 8 Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil paintingofapproved quality and shade etc. complete. 9 Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/sq.mt. totalon each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550MPayieldstrength, metallic hot dip coated with Aluminium-Zinc alloy (55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganicpigment).Thepaintshallhaveatotal coatingthicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050mmeffectivecoverwidthandnominal25-30mmdeepribswithsubtlesquare fluting in the five pan at nominal 180-250 mm center- to-center.The endribshallbe designedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturersproductdetailsmarkedaregularinterval.Includingfastenerswithmin. fastenedwithmin.25umZinc-Tinalloycoated,Hexhead,self-drillingscrewetc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) 10 Providing and fixing of colour coated Zincaluminium( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550MPayieldstrength,metallichotdipcoatedwithAluminium-Zincalloy(55% aluminiumm43.4%zinc1.6%silicon)withCOLORBOND(R)steelqualitysuper durablepolysterpaintcoat(with inorganicpigment).Thepaintshall havea total coating thickness ofnominal 35mm, comprising of nominal 25mmexterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050mmeffectivecoverwidthandnominal25-30mmdeepribswithsubletsquare fluting in the five pan at nominal 180-250 mmcenter- to-center.Theendribshallbe designedforanti-capacitygroove.andreturnleg.Thefeed material should have coil manufacturersproductdetailsmarkedaregularinterval.includingfastenerswithmin. fastenedwithmin.25umZinc-Tinalloycoated,Hexhead,self-drillingscrewetc. complete. (weight of profile 4.52 Kilogram/ One Square Metre)600 mm girth (Surface Width). 11 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 12 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mm Aggregate) 13 Providing and laying in situ cement concrete M -30 with tremix treatment for 200 mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen ( excluding reinforcement) with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) etc. complete with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.(Non SCADA Item) 14 Supplying hard murum/ kankar at the road site, including conveying and stacking complete 15 Spreading hard murum/ soft murrum/ gravel or kankar for side width complet 16 Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete 17 Providinguncoursedrubblemasonryoftrap/granite/quartzite/gneissstonesin cement mortar1:6infoundationandplinthofinnerwalls/inplinthofexternal walls includingbailingoutwatermanually,strikingjointsonunexposedfacesandwatering etc.complete. 18 Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) 19 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete 20 Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. 21 Providing and applying washable oil-bound distemper of approvedcolour andshade to oldand new surfacesintwocoatsincludingscaffolding,preparingthesurfaces.(excluding the primer coat.) etc. complete. 22 Providing flush grooved pointing with cement mortar 1:3 for stone masonry work including scaffolding and curing etc. complete. 23 BRICKS. 1)Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5Bricks), Efflorescence (Set of 5 Bricks) 24 CONCRETE PAVING BLOCKS. 1)Compressive Strength , Water Absorption,(Set of 8 Blocks) 25 CONCRETE. 1)Compressive Strength OF C.C. Cube (Set of 3 cubes). 26 SOIL / MURUM. 2)Liquid limit & plastic Limit. 27 Royalty For Natural Sand - Screened (for plaster work only) 28 Royalty For Rubble stone excluding royalty 29 Royalty For Hard Murum 30 Royalty For Murum at Site
Contract Date: Jun 09, 2026 Contract Value : 6.85 Lakh
Government Departments No of Bidders 5
Maharashtra View Result →
50.
Rural Development #10794186 Price Bid
Tender For Building The Maruti Sabha Mandap At Kenjal Phirangai, Tal. Bhor- 1 Part - A Excavation for foundation in earth,soil of all types,sand,gravel and soft murum, including removing the excavated cmaterial up to a distance of 50m.beyond the building area and stacking and spreading as directed,dewatering,preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 2 Excavation for foundation in hard murum including removing the excavated material upto distanceof50metresbeyondthebuildingareaandstackingandspreadingas directed,dewatering, preparing the bed for the foundation and necessary back filling,ramming, wateringincludingshoringandstruttingetc.complete.(Liftupto 1.50m)ByMechanical Means 3 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 4 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (Non SCADA Item) 5 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Concrete Non Scada) 6 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 7 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Non SCADA Item) 8 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 9 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete 10 Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.Layers including watering and compacting etc. complete. 11 Filling in plinth and floors with contractorsmaterial/brought from outside and approved byEngineer inchargein layers of 15 cmto 20 cm including watering andcompactionetc. complete. 12 Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete. 13 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 14 Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. 15 Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/sq.mt. totalon each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550MPayieldstrength, metallic hot dip coated with Aluminium-Zinc alloy (55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganicpigment).Thepaintshallhaveatotal coatingthicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050mmeffectivecoverwidthandnominal25-30mmdeepribswithsubtlesquare fluting in the five pan at nominal 180-250 mm center- to-center.The endribshallbe designedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturersproductdetailsmarkedaregularinterval.Includingfastenerswithmin. fastenedwithmin.25umZinc-Tinalloycoated,Hexhead,self-drillingscrewetc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) 16 Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. 17 Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete 18 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete 19 Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. 20 Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. 21 Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. 22 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium platedfixturesandfastenings,withbrassmortiselock,chromiumplated handlesonboth sides, and finishing with French Polish etc. complete. 23 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight0.547Kilogram/OneRunningMetre.andwindowframebottomtracksection61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/One Running Metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/One Running Metre. Theshutter should beof bearing bottom 40x 18x 1.25mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/OneRunningMetre.andtopsection40x18x1.25mmatweight0.417 Kilogram/Runningmetre.AsperdetaileddrawingsandasdirectedbyEngineerin chargewithallnecessaryAluminiumsectionsfixturesandfasteningssuchasroller bearinginnyloncastingandselflockingcatchfittedinverticalsectionofshutter including5 mm thick plain glass with all required screws and nutsetc, complete.With powder coating without box 24 Providing and fixing partition of welded mesh of 3 mm dia. wires 50 mm x 25 mm size mesh including integratednonteak seasoned woodframe 80x 50mm ofvertical and horizontal scantling and finishing with oil painting 3 coats etc. complete 25 Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metreasperdrawingincludingfixturesnecessaryweldingandpaintingwith onecoatof anticorrosive paint and two coats of oil painting complete. 26 Providing and applying two coats of exteriorweather shield paint of approved manufactureand of approved colour to the plastered surfaces including cleaning,preparing the plastersurface,applyingprimercoat,scaffoldingifnecessary,and watering the surface for two days etccomplete. NOTE: ForItem One Number 15 to 18 prior approval of Superintending Engineer will be necessary 27 Providing and applying washable oil-bound distemper of approvedcolour andshade to oldand new surfacesintwocoatsincludingscaffolding,preparingthesurfaces.(excluding the primer coat.) etc. complete. 28 Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand) 29 Providing and fixing board displaying information, such as Name of work, Tender cost,Name of Contractor, Work completion and liability period etc, having rectangular shapeof 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted withone coat of Zinc chromate stoving primer and two coats of enamel paint on front side andgrey stove enamel on back side and border / messages / symbols etc. with approved colourshade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly crossbraced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angleiron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black andwhite bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling,transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
TenderDetail
Loading tenders