View Bid Results For Remote Terminal Tenders

We found 984 Bid Results related to remote terminal tenders. You can find Contractor details who won remote terminal tenders along with contract details in Bid awards announcements section.

Filters
Stage
694
205
85
Tender Publishing Platform
148
836
State / UT
35
183
137
92
71
68
57
43
40
37
30
26
21
20
19
19
18
18
11
11
11
9
8
8
5
4
4
3
2
2
2
1
1
1
1
1
Contract Value
312
112
349
210
Publish Date
1
0
0
0
0
Sector
29
267
168
85
80
50
47
40
38
32
23
21
19
19
14
13
12
12
8
7
7
4
4
3
3
2
2
2
1
1
Ownership
6
452
288
136
89
18
1
Within keyword
Active filters:
Showing 1–20 of 984 tenders matching your filters
1.
Power #11482346 AOC
Procurement Of 03 Nos. Of 31.5 Mva, 132/34.5Kv Power Transformers , Main Items: , 31.5 Mva, 132Kv / 34.5Kv, 50Hz, Ynd1, Star (Earthed Neutral) / Delta, Core Type, 3 Phase, Outdoor Type, Oil Immersed, Onan/ Onaf Cooled Switchyard Transformer Complete With Main Tank, Tank Mounted Cooler Bank, On Load Tap Changer (Hv Side) Suitable For Voltage Variation Of +/- 10% Variation, Cc Cubicle, Digital Rtcc Panel Along With All Fittings & Accessories As Per Requirement Of Technical Specification (Except Transformer Oil, N2 Fpes) , Transformer Oil For First Filling Plus 10% Extra Quantity. , Complete Set Of Equipment For Fire Prevention & Extinguishing System By Nitrogen (N2) Injection Method As Per Technical Specification Including Supply Of All Control Units & Accessories, Pipe, Connectors, Required Control Cables, Ac / Dc Converters Etc. All Complete Along With Supply Of Spare N2 Cylinder For Above Transformer. , Condition Controlled Regenerative Maintenance Free Silica Gel Breather For Main Conservator Complete With All Accessories , Condition Controlled Regenerative Maintenance Free Silica Gel Breather For Oltc Conservator Complete With All Accessories , Type Test Charges As Per Spec.: , Temperature Rise Test On One Unit , Impulse Test On One Unit , Mandatory Spares (For Above Transformer): , Hv Bushing As Per Spec. With Metal Parts & Gaskets , Lv Bushing As Per Spec. With Metal Parts & Gaskets , Hv Neutral Bushing As Per Spec. With Metal Part & Gaskets , Buchholz Relay (With Alarm & Trip Contacts) For Main Tank , Oil Surge Relay (With Alarm / Trip Contacts) For Oltc , Magnetic Oil Level Gauge (With Alarm / Trip Contact) For Main Conservator , Magnetic Oil Level Gauge (With Alarm / Trip Contact) For Oltc Conservator. , Current Transformer Of Hv Wti. , Current Transformer Of Lv Wti. , Current Transformer Of Hv-N , Local Oti Complete With Alarm, Trip Contacts & Sensing Device, Etc. , Local Wti Complete With Alarm, Trip Contacts & Sensing Device, Etc. , Remote Oti Complete With Alarm, Trip Contact & Sensing Device Etc. , Remote Wti Complete With Alarm, Trip Contact & Sensing Device Etc. , Pressure Relief Device , Remote Tap Position Indicator , Cooling Fan With Motor , Terminal Connectors (1No.T For Each Type Of Rating) , Set Of Gaskets Required For Complete Erection Of One Transformer Including Bushings, Radiators, Cooling Pipes Etc. , Transformer Oil Sample Collection Bottle (Steel Bottle Fitted With Inlet & Outlet Valves, Etc.) - 1000 Ml Capacity , Hydraulic Jacks Suitable For Above Transformer (1 Set Consisting Of 4 Nos.) , Unloading Charge Per Unit At Site (1 Unit Means Complete Set Of Transformer With All Accessories, Spares, Tools & Tackles Etc.) , Supervision Charges For Deputation Of Engineer / Technician To Supervise Erection & Commissioning Work. (Optional) – [N.B. General Terms & Conditions For Supervision Of Erection & Commissioning Job Shall Be Furnished] Engineer / Technician Per Day
Contract Date: Jul 01, 2026 Contract Value : 10.93 Crore
Boards / Undertakings / PSU No of Bidders 2
West Bengal View Result →
2.
Science and Technology #11440503 Technical Bid
Tender for Earth Work , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lif. , Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , Cement Concrete (Cast In Situ) , Providing And Laying In Position Excluding Cement Concrete Of Level: Specified Grade The Cost Of Centering And Shuttering - All Work Up To Plinth 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Ill) Derived From Natural Sources: 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Ill) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Stone Work , Coursed Rubble Masonry (Second Sort) With Hard Stone In Foundation & Plinth With :Cement Mortar 1:6(1 Cement : 6 Coarse Sand) , Cladding Work , Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge,Granite Work , Wood And P. V. C. Work , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Sal Wood , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , Providing 40X5 Mm Flat Iron Hold Fast 400 Mm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 300X100x150 Mm 1:3:6 Mix (1 Cement: 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). , Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. , Providing And Fixing Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete. , Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Twin Rubber Stopper , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Lnline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge. Wire Mesh / Glazing Of Plain/ Toughened/ Laminated/ Double Glass Unit With / Without High Performance Coatings As Per Design Requirements And Conforming To Is: 3548 & Is: 16231 Shall Be Paid Separately. Note:- Structural Design Proof Checked From A Government Engineering Institute, To Be Provided By The Manufacturer For (I) Sites With Basic Wind Speed 45 M/Sec As Per Is 875 - Part 3 (Ii) Sites With Structure Height More Than 20M For All Wind Speedscasement Window Double Panels With Fixed Mullion With S.S. 304 Friction Hinges As Per Size And Weight Of Sash, Multi-Point Locking System, Zinc Alloy (Zamak) Powder Coated Handles.Using R2 Series With Frame (39 Mm & Above) X (39 Mm & Above) & Sash (39 Mm & Above) X (60 Mm & Above) & Mullion (39 Mm & Above) X (60 Mm & Above). (Height Upto 1.2 Metre). , Steel Work , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Flooring , Providing And Laying Vitrified Tiles In Floor In Diferent Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Double Charge Vitrified Tile Polished Finish Of Size Of Tile 600 X 600 Mm , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Finishing , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Coarse Sand) , 6 Mm Cement Plaster 1:3 (1 Cement: 3 Fine Sand) Finished With A Floating Coat Of Neat Cement And Thick Coat Of Lime Wash On Top Of Walls When Dry For Bearing Of Reinforced Cement Concrete Slabs And Beams. , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , 12 Mm Thick Plain Cement Mortar Bands In Cement Mortar 1:4 (1 Cement: 4 Fine Sand):Moulded Band , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Itr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm) , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade :Two Or More Coats On New Work , French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler , Wall Painting With Acrylic Emulsion Paint, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour.Two Coats , Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc (Volatile Organic Compound ) Content.With Water Thinnable Cement Primer On Wall Surface Having Voc Content Less Than 50 Grams/Litre , Dismantling And Demolishing , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge.Nominal Concrete 1:3:6 Or Richer Mix (Including Equivalent Design Mix) , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , Aluminium Work , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Filling The Gap In Between Aluminium Frame & Adjacent Rcc/ Brick/ Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete.Upto 5 Mm Depth And 5 Mm Width , Market Rate Items , Provinding Precast Cement Concrete Solid Block Masonry Including Hoisting And Setting In Position With Cement Mortar 1:6 (Cement :6 Coarse Sand) Completed As Per The Direction Of Engineer In Charge As Per Site Condition , Providing And Fixing 5 Mm Thick Clear Transparent Acrylic Sheet Of Approved Brand And Manufacture For Fixed Curved Portions In Openings, Including Epdm Rubber/Neoprene Gasket And All Necessary Accessories, Complete In All Respects As Per The Directions Of The Engineer-In-Charge. , Electrical Work , Laying And Fixing Of One No Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq.Mm (Clamped With 1Mm Thick Saddle) Size On Wall Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 4 X 16 Sq. Mm (25Mm) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. , Supplying And Fixing Of 4 Way (4 + 12), Double Door Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs As Required . , Supplying And Fixing 6 Way, Double Door, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator. , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole And Neutral , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 6 Module (200Mmx125mm) , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5/6 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15/16 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15/16 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , 2M Stepped Type Electronic Fan Regulator , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Group Controlled (Looped) Light Point/ Fanpoint/ Exhaust Fan Point/ Call Bell Point (Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit,And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. (Group-C) , Providing And Fixing 6 Swg Dia G.I Wire On Surface Or In Recess For Loop Earthing As Required. , Supplying, Installation, Testing & Commissioning Of Photo Electronic Smoke Detector With Builtin Led And Mounting Base Plate Suitable With Ms Junction Box For Operation On 12V / 24V Complete With All Connections Etc. As Required. , Supplying, Installation, Testing & Commissioning Of Manual Call Box Of Abs Type In Surface/Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc. As Required. , Supplying & Laying Of 2 X 1.5 Sqmm Fire Alarm Armoured Cable, 600/1000V Rated With Annealed Copper Conductor Having Xlpe Insulation, Steel Wire Armouring & Frls Outer Sheath Complete As Required. , Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With Upto 32A, 240 V, C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing 30 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 32 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Spmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep,Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Speed Control Compitable For Electronic Type Regulator And All Remaining Accessories Including Safety Pin,Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Including Fixing Fan Hook In Ceiling Complete As Required. , Supplying, Installation, Testing & Commissioning Of Panel Light 2X2 Ft.,40W Of Powder Coated Die Cast / Extruded Aluminium Body (Thickness ≥ 1.20 Mm) Body Material And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency 85%, Operating Voltage Ac 140 270 Volt, Freq 50/60 Hz, Operating Temp Range -15 Deg To 40 Deg Centigrade, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection, Thd 10% , P. F.≥0.95, Ip20, Cri 80, Ugr (Unified Glare Rating) 19, Flicker Free, (Flicker Should Be Below 5 %), Life Time (Led,Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With, 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11Report, Cct 5700°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. System Lumen Efficacy ≥105 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. , Supplying And Fixing Of 25Mm Size Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Drawing 1 Run Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended/Surface Mount From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 V, Complete As Required. , Supplying And Fixing Fp Mcb Sheet Steel Enclosure With Din Rail On Surface / Recess Etc. As Required. , Supplying & Fixing Of 4Pole, 63 A Rating, 415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 16Sq.Mm, Aluminium , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 6Sq.Mm, Copper , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,3C X 4 Sq.Mm, Copper , Supply And Laying Of Un Armoured Copper Single Core 10 Sq.Mm Flexible Cable With Annealed Copper Conductor In Suitable Size Hdpe Pipe In Ground/ On Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.4 X 6 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.3 X 4 Sq.Mm , Supply ,Installation, Testing And Commissioning Of 2 Tr/24000Btu Per Hour And Bee-5 Star Rated Wall Mounted Inverter Type Hi Wall Split Cooling Air Conditioner Having Wireless Remote Controller, Hermetically Sealed/Scroll/Rotary Compressor And Eco Friendly Refrigerant,Initial Charge Of Refrigerant,Condensor And Evaporator Coils Of Copper Material, Air Filter With Auto Swing & Auto Restart Features, Suitable For Operation On 230V, Single Phase, 50Hz, Ac Power Supply. The Indoor Unit Shall Be Fixed Rigidly On Wall Using Necessary Frame, The Outdoor Unit Shall Be Mounted On Wall Or Floor Using Suitable Powder Coated Ms Angle Frame As Required. Including Clamps, Bolts, Nuts,Vibrating Dampers, Laying Of 3 Meter Standard Length Of Copper Refrigerant Piping With 3 Meter Pvc Covering Pipe, 3 Meter Drain Piping, Wrapping Tape And Necessary Insulation ,Electrical Flexible Cable Connectivity Between Indoor And Outdoor Unit. Necessary Drilling Of Hole And Finishing The Same To Match For The Surrounding As Required. , Supplying And Fixing Of Frp Box 200Mmx140mmx95mm Size (Nominal Size) On Surface With Hinged Door With Suitable Grounding Copper Bar Link With Holes Fitted Inside The Box Etc. As Required. , Supplying And Fixing Of Dual Rj 45 / Io Outlet On Existing Modular Switch Plate. , Supply,Installation,Testing And Commissioning Of Maintenace Free Earth Pit Of Single Pipe Technology Copper Pipe Of 2000Mm Long (Min), Outer Dia 50 Mm, Wall Thickness 1.2Mm(Min), Filled With Highly Conducting Metallic Compounds With The Permanent Sealing At Both The Ends And Lead Terminal Of 50 X 10 Mm Size At The Top The Length Of The Electrode Shall Be 2000 Mm Excluding The Lead Terminal And The Length Of The Lead Terminal At The Top Shall Be Minimum 50Mm. To Ensure The Moisture Content And Electrical Conductivity, Resistance Lowering Grounding Minerals Shall Be Filled Around The Electrode Of (Min25 Kg) .Heavy Duty Weather Proof Plastic Earth Pit Chamber With Cover Of Dimension 300 Mm Dia (Top), 260 Mm Dia(Bottom) And 300 Mm (Height) Shall Be Used, Numbering Of Pit And Measured Value Written With Weather Proof Painting Or Stickering. As Required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
3.
Power #11382206 AOC
Procurement Of 06 Nos. Of 80 Mva, 132 Kv 34.5Kv Power Transformer Procurement Of 06 Nos. Of 80 Mva, 132 Kv 34.5 Kv Power Transformer , Main Items: , 80 Mva, 132Kv / 34.5Kv , 50Hz, Ynd1, Star (Earthed Neutral) / Delta, Core Type, 3 Phase, Outdoor Type, Oil Immersed , Onan/ Onaf/ Ofaf Cooled Switchyard Transformer Complete With Main Tank, Tank Mounted Cooler Bank, On Load Tap Changer (Hv Side) Suitable For Voltage Variation Of +/- 10% Variation, Cc Cubicle, Digital Rtcc Panel Along With All Fittings & Accessories As Per Requirement Of Technical Specification (Except Transformer Oil, N2 Fpes) , Transformer Oil For First Filling Plus 10% Extra Quantity , Complete Set Of Equipment For Fire Prevention & Extinguishing System By Nitrogen (N2) Injection Method As Per Technical Specification Including Supply Of All Control Units & Accessories, Pipe, Connectors, Required Control Cables, Ac / Dc Converters Etc. All Complete Along With Supply Of Spare N2 Cylinder For Above Transformer , Condition Controlled Regenerative Maintenance Free Silica Gel Breather For Main Conservator Complete With All Accessories , Condition Controlled Regenerative Maintenance Free Silica Gel Breather For Oltc Conservator Complete With All Accessories , Type Test Charges As Per Spec.: , Temperature Rise Test , Impulse Test , Mandatory Spares (For Above Transformer): , Hv Bushing As Per Spec. With Metal Parts & Gaskets , Lv Bushing As Per Spec. With Metal Parts & Gaskets , Hv Neutral Bushing As Per Spec. With Metal Part & Gaskets , Buchholz Relay (With Alarm & Trip Contacts) For Main Tank , Oil Surge Relay (With Alarm / Trip Contacts) For Oltc , Magnetic Oil Level Gauge (With Alarm / Trip Contact) For Main Conservator , Magnetic Oil Level Gauge (With Alarm / Trip Contact) For Oltc Conservator. , Current Transformer Of Hv Wti. , Current Transformer Of Lv Wti. , Current Transformer Of Hv-N , Remote Oti Complete With Alarm, Trip Contact & Sensing Device,Etc. , Remote Wti Complete With Alarm, Trip Contact & Sensing Device,Etc. , Pressure Relief Device , Oil Flow Indicator With Flow Switch , Remote Tap Position Indicator , Cooling Fan With Motor , Cooling Pump With Motor , Terminal Connector For Hv Bushing Suitable For Acsr Moose Conductor , Terminal Connector For Lv Bushing Suitable For 2.5-Inch Aluminium Tube (Expansion Type) , Unloading Charge Per Unit At Site (1 Unit Means Complete Set Of Transformer With All Accessories, Spares, Tools & Tackles Etc.) , Supervision Charges For Deputation Of Engineer / Technician To Supervise Erection & Commissioning Work. (Optional) – [N.B. General Terms & Conditions For Supervision Of Erection & Commissioning Job Shall Be Furnished] Engineer / Technician Per Day
Contract Date: Jun 26, 2026 Contract Value : 39.50 Crore
Boards / Undertakings / PSU No of Bidders 3
4.
Chemicals and Fertilizers #11371335 AOC
Bids Are Invited For Spares For Jrs Make Bagging Machine Total Quantity : 117; 1 711803138 PAN SUPPORT BRACKET FOR LOAD CELL ASSEMBLY OF UBM-85 BAGGING MACHINE MAKE : JASUBHAI ENGINEERING PVT. LTD 2 Number 2 075123132 SPARES FOR BAGGING MACHINE Equipment : JRS BAGGING MACHINE Model : UBM-85 Make : JRS Supplier : JASUBHAI MATERIAL HANDLING SYSTEMS PVT LTD Flexible Jaw Connection (Rubber) Area : Bag Holding 30 Number 3 828883910 SWINGING BAFFLE FOR INLET ASSEMBLY (SPOUT ASSEMBLY) OF UBM -85 BAGGING MACHINE MAKE : JASUBHAI ENGINEERING PVT.LTD 3 Number 4 841101004 DIGITAL BAG COUNTER Mounting : Flush panel mounting Panel cut out size: 29mm x 71mm. (+/- 2mm) Display : Digital LED display (Seven segment) Display size : 6 Digit, 0. 3 inch Height Display Colour : Red. Number of input channels: One Input : Potential free contact Range : 999999 Counts. Counting direction : Upward Reset Option : Required i) On front panel. ii) Remote reset ( Via rear terminals) Output : Not required Power Supply : 24 VDC Power Comsumption : 5 VA max. Temperature : 20 to 50 Deg.C Humidity : 95% RH. Housing : Flame retardent Plastic. Protection Level: IP 65 Weight : Approx 110 grams 4 Number Please submit your offer for supply of the following items as per the instructions, technical specifications and other terms and conditions specified herein/ attached. Note: 1. The delivery period mentioned in the BoQ is our indicative requirement. You may offer your earliest delivery period. 2. Please refer our above referred enquiry number in all correspondence. 5 841200142 PNEUMATIC CYLINDER, 40 x 100 STROKE WITH CT(FEMALE)WITH MOUNTING, PISTON ROD END BLOCK AND PISTON ROD END PIN FOR DRIBBLE VALVE, PISTON SHAFT THREAD-NPT 6 Number 6 841200143 PNEUMATIC CYLINDER, 40 x 100 STROKE WITH RC MOUNTING, PISTON ROD END BLOCK AND PISTON ROD END PIN, FOR BOMB PAN DOOR, PISTON SHAFT THREAD-NPT 8 Number 7 841200160 PNEUMATIC CYLINDER, 80 x 60 STROKE WITH CT WITH MOUNTING, PISTON ROD END BLOCK AND PISTON ROD END PIN, FOR BB80, PISTON SHAFT THREAD-NPT 8 Number 8 841200184 REPAIR KIT FOR 80 x 60 CT CYLINDER INCLUDING CUP, GLAND O-RING, GUIDE AND WIPER 10 Set 9 841200201 Relay Board for JASUBHAI JB07 Bagging Machine Controller / Control Panel 5 Number 10 841200202 PLC Relay for JASUBHAI JB07 Bagging Machine Controller / Control Panel 5 Number 11 841200203 Timer for JASUBHAI JB07 Bagging Machine Controller / Control Panel 3 Number 12 841200204 EMI Filter for JASUBHAI JB07 Bagging Machine Controller / Control Panel 3 Number 13 841200241 REPAIR KIT FOR 40 x 100 CT CYLINDER INCLUDING CUP, GLAND O-RING, GUIDE AND WIPER 6 Number 14 841200242 REPAIR KIT FOR 40 x 100 RC CYLINDER INCLUDING CUP, GLAND O-RING, GUIDE AND WIPER 10 Number 15 841200251 Complete Pneumatic BB – 80 Bag Holder Assembly with 2 Nos. Cylinder, Bag Feeler Sensor, Bag Clamp Sensor Assembly Material of construction : SS (for JASUBHAI BAG. MACHINE- UBM 85) 1 Number 16 841200256 Spare OCP indicator for UBM 85 Net weighing/Bagging Machine Make : Jasubhai Engg. Pvt Ltd Model: JB RD 01 4 Number 17 841200257 SS 316 WEIGH PAN with CYLINDERS (for JASUBHAI BAGGING MACHINE-UBM 85) 1 Number 18 841200501 SMPS for JASUBHAI JB07 Bagging Machine Controller / Control Panel 2 Number 19 841467215 INDUCTIVE SLOT SENSOR MAKE : PEPPERL + FUCHS MODEL : SJ 15 - E2 SLOT WIDTH : 15 MM OPERATING VOLTAGE: 10-30 VDC CONNECTION TYPE : 2 METER PVC CABLE PROTECTION : IP 67 6 Numbe
Contract Date: Ref. Documents Contract Value : 10.60 Lakh
Government Departments No of Bidders 1
5.
Petroleum and Natural Gas #11370921 AOC
Bids Are invited for Procurement Of Spares For Mass Flowmeter N Transmitters Installed At Gail Gujarat Reg On Oem Basis Tm,Flow,Remote,P_N_2700C11abfezwz_Material Code_8108115523 - Refer Scc And Technical Specification , Terminal Block Kit For 9-Wire Sensor Con_Material Code_8108119633 - Refer Scc And Technical Specification , Feature Board Stack,F_Fm,2700C Mvd,Emers_Material Code_8108115123 - Refer Scc And Technical Specification , Sensor,Terminal Block_Material Code_8108959643 - Refer Scc And Technical Specification , Terminal Block Kit For 9-Wire Sensor Con_Material Code_8108119633 - Refer Scc And Technical Specification , Display Sub Assembly,1700_2700,Emerson_Material Code_8108111233 - Refer Scc And Technical Specification , Feature Board Stack,F_Fm,2700C Mvd,Emers_Material Code_8108115123 - Refer Scc And Technical Specification , Sensor,Terminal Block_Material Code_8108959643 - Refer Scc And Technical Specification , Core Processor,W_Cap,F_Puck 1700_2700_Material Code_8108958353 - Refer Scc And Technical Specification , Tm,Flow,Remote,P_N_2700C11abfezwz_Material Code_8108115523 - Refer Scc And Technical Specification , Terminal Block Kit For 9-Wire Sensor Con_Material Code_8108119633 - Refer Scc And Technical Specification , Display Sub Assembly,1700_2700,Emerson_Material Code_8108111233 - Refer Scc And Technical Specification , Feature Board Stack,F_Fm,2700C Mvd,Emers_Material Code_8108115123 - Refer Scc And Technical Specification , Core Processor Assembly,Enhcpassy,Emerso_Material Code_8108143373 - Refer Scc And Technical Specification , Flow T_M, 2700R12abfezwz_Material Code_8108111323 - Refer Scc And Technical Specification , Sensor,Terminal Block_Material Code_8108959643 - Refer Scc And Technical Specification , Core Processor,W_Cap,F_Puck 1700_2700_Material Code_8108958353 - Refer Scc And Technical Specification , Electronic Stack For Mvd 2700R_Material Code_8108111313 - Refer Scc And Technical Specification Total Quantity : 27
Contract Date: Ref. Documents Contract Value : 46.73 Lakh
Boards / Undertakings / PSU No of Bidders 1
7.
Drinking Water Supply and Sanitation #11348134 Technical Bid
Tender for E-Quotation For Seeking Firm Rates Of Plant & Machinery And Materials Category Items For Preperation/Amendment Of Schedule Of Rate For The Year 2026. , M 1055 - Pumps Supplying Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene/ Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon/ Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single/ Double Run Shall Be Provided With Each Pump. , Submersible Pump Set 100 Mm Dia (With Polypropylene/ Noryl Impeller) Up To 20 Stages 1 H.P. , 1.5 Hp , 2.5 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , Submersible Pump 150 Mm Dia (With Bronze/Ss Impeller) Up To 8 Stages , 1.5 Hp , 2.0 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , 6.0 Hp , 7.5 Hp , M 1056 - Pressure Guage Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint , Pressure Gauge (100 Mm Dia) , Pressure Gauge (150 Mm Dia) , Vacuum / Combination Gauge , M 1057 - Lifting Equipment Chain Pulley Block Supplying Triple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. , 1 Tonne Capacity , 2 Tonne Capacity , 3 Tonne Capacity , Electric Operated Circular Or Rectangular Travelling Crane (Single Girder) Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. , 5 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , 7.5 Tonne Capacity , Above 6 M Upto 8 M Span , Above 8 M Up To 10 M Span , 10 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , M 1058 - Lightening Arrester, Ab Switch, Insulators , Lightening Arrestor Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. , Suitable For 11 Kv Supply, Distribution Class , Suitable For 22 Kv Supply, Distribution Class , Suitable For 33 Kv Supply, Station Class , Disc Insulator. Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Pin Insulator Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Air Break Switch Without Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11Kv Line , Rocking / Tilting Type , Rotating Type , Suitable For 33Kv Line , Rocking / Tilting Type , Rotating Type , Air Break Switch With Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11 Kv Line , Rotating Type , Suitable For 33 Kv Line , Rotating Type , Drop Out Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , Horn Gap Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , M 1059 - Transformer Power Transformer (With Off Load Tap Changer) Any Isi Mark , Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issed By Seb Which Ever Are Lower- 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. , Power Transformer 11000/433 Volts With Off Load Tap Changer - 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. , 63 Kva , 100 Kva , 160 Kva , 200 Kva , 250 Kva , 315 Kva , 500 Kva , 630 Kva , 750/800 Kva , Power Transformer (With On Load Tap Changer) Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- , 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. 12. Buchholz Relay 13. Resistance Temp. Detector 14. Marshalling Box 15. Automatic Voltage Regulator (Avr) 16. Remote Tap Changing Controller (Rtcc) , Transformer 11000/433 Volts With On Load Tap Changer - 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification , 750/800 Kva , 1000 Kva , 1250 Kva , 1600 Kva , 2000 Kva , M 1060 - Motors Foot Mounted Motors Tefc 1500 Rpm Supplying Foot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts ± 10%, 3 Phase, 50 Hz ± 3% With F Class Insulation Temperature Rise Limited To Class B Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. , 15 Kw (20 Hp) , 18.5 Kw ( 25 Hp) , 22 Kw ( 30 Hp) , 30 Kw ( 40 Hp) , 37 Kw ( 50 Hp) , 45 Kw ( 60 Hp) , 55 Kw ( 75 Hp) , 75 Kw ( 100 Hp) , 90 Kw ( 120 Hp) , 110 Kw ( 150 Hp) , 132 Kw ( 180Hp ) , 160 Kw ( 215 Hp ) , M 1061 - Aluminium Cable Cable - Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150 Sq Mm , 3 Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated Supplying Ht Aluminium Three Core Cable Xlpe Insulated ,Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape (0.3 Ka For 1 Sec.) Cores Laidup Inner Sheath Of Pvc Tape ,Galvanised Steel Flat Strip Armoured,And Overall Pvc Sheathed Cable Conforming To Is :7098 /Ii/85 With Latest Amendments , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core150sq Mm , 3 Core 185 Sq Mm , 3 Core 240Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1062 - Copper Cable Cable , 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3 .5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3 .5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor 3.5 Core Xlpe/Pvc Unarmoured Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3.5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3.5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150Sq Mm , 3Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1063 - Foot Valve Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. , Flanged Type , 50 Mm , 65 Mm , 80 Mm , 100 Mm , 125 Mm , 150 Mm , M 1064 - Air Circuit Breaker Acb Breaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole , 1000A , 1250A , 1600A , 2000A , M 1065 - Starter D.O.L. Starter With Ss Enclosure With 380/415 Volt Coil , 5 To 10 Hp , Supplying Fully Automatic Star Delta Starter To Operate Induction Motor Working On 415V,3Phase,50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser F.A.S.D Starter , 10 Hp , 20 Hp , 25 Hp , 40 Hp , 50 Hp , 75 Hp , 100 Hp , 125 Hp , 150 Hp , 250 Hp , M 1066 - Servo Controlled Automatic Voltage Stabilizer Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt ± 1%, 3 Ph, 50 Hz, With Copper Wound Transformer (Air/Oil Cooled) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And Users Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto/Manual Selector Switch, Raise/Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated 􀂌 Over Voltage / Under Voltage 􀂌 Single Phasing 􀂌 Cut Off Contactor With Electronic Output Sensing Unit , Servo Controlled Automatic Voltage Stabiliser(Out Put 415 ± 1%) Input 150 / 220 To 450 / 460 Volt , 30 Kva Air Cooled , 40 Kva Air Cooled , 50 Kva Oil Cooled , 60 Kva Oil Cooled , 75 Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , Servo Controlled Automatic Voltage Stabiliser (Out Put 415 ± 1%) Input 280 To 450/460 Volt , 15 Kva Air Cooled , 20 Kva Air Cooled , 30 Kva Air Cooled , 40 Kva Air Cooled , 50Kva Air Cooled , 60 Kva Oil Cooled , 75Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , 150 Kva Oil Cooled , 200Kva Oil Cooled , M 1067 - Termination Kit Providing And Errecting In-Door Type Termination Kit, For 3.3Kv/ 6.6 Kv / 11Kv/ 22Kv/33Kv Xlpe Screened 3 Core Cable , In-Door Termination Kit For 3.3Kv(E/Ue) / 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out-Door Termination Kit For 3.3(E/Ue)/6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 3.3Kv(E/Ue)/ 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 11 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 22 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-150 Mm² , 185-240 Mm² , 300-400 Mm² , In Door Termination Kit For 33Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 33 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Straight Through Joint For 33 Kv(E) Xlpe Screened 3 Core Cable , 35-70 Mm² , 95-150 Mm² , 185-240 Mm² , 240-300 Mm²
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : 3.91 Lakh
Boards / Undertakings / PSU No of Bidders 1
9.
Housing Urban and Rular Development #11319892 AOC
Quotation for NON CSR Electrical Item for the work supply installation testing and commissioning of Electrification at the Mahalaxmi Temple, Kolhapur,Dist.Kolhapur- 1 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (4 m poles) 2 Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG Set). 3 SITC of ESE type Lightning Arrestor Air Terminal as per standard NFC 17-102, Level IV with protection radius 51 mtr @ mounting height 5 meter.LA should be have CPRI test cerficate and should have test cerficate as per NFC 17-102 of suitable europian authority. 4 SITC of 3 meter height Mounting structure MAST (FRP/G.I.), along with supporting guy rope, base plate, mounting structure, required nut bolts etc. 5 SITC of Strike Recorder with weather proof Enclousure. It should be standalone type with no external power source requirement. 6 SITC of Test Link 7 SITC of Pipe in Pipe type GI maintanance free earthing - 80/38 (3.0 Mtr.s) with all other loose acessories and earthing pit chamber and cover. 8 SITC of single core 35 Sq. MM. Insulated Alm. Armoured Cable along with all installation accessories like clamp etc. (Optional) from LA to Earth Pit. Manufacturer to specify Copper/Aluminium). 9 Supplying, fixing and commissioning of MLTP including: Incoming - 200A MCCB 25 KA-2 nos, 200A ATS 4P - 1 Nos, Bus 250A Aluminium Outgoing : 63A 4P MCB - 5 Nos, 40A 4P MCB- 10 Nos, 125A 4P MCCB - 1 Nos, 160A SP MCCB - 1 Nos with floor mount stand 10 Supplying, fixing and commissioning of LTFP with 200 AMPS MCCB Incomer 8 Nos. Outgoing with 40 AMPS FPMCB 11 Providing & erecting 4 Pole MCCB, 415 V, 125A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 12 Providing & erecting 4 Pole MCCB, 415 V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 13 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates & hardware. 14 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 100 mm width & 50 mm height complete with necessary coupler plates & hardware. 15 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm x 200 mm complete with necessary cover plates & hardware. 16 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm x 300 mm complete with necessary cover plates & hardware. 17 Supply and Installation of 5MP PoE IP Bullet Camera with automatic varifocal lens from 3.3 to 10 mm lens and 30 meter inbuilt IR, Dual Streams with configurable bit rate, GOP and frame rate, Edge based Video Analytics- object classification (Human/Vehicle), object in field, line crossing, enter field, leave field, loitering, follow route, objects stopping or starting to move, counting, occupancy, condition change, similarity search, 16 number of analytics/rules can be configured simulaneously. The video analytics software can detect up to 64 objects per frame in real time. support memory card up to 2TB capacity with health monitoring for early service indication. The recording in local storage should also be AES encrypted, support ONVIF S,G,T,M with MQTT event forwarding, onboard data security by using TPM (Trusted Platform Module) and PKI, supports TLS 1.3, Secure boot, Signed Firmware, software sealing to notify of device configuration changes, Embedded Login Firewall to minimize DDOS Attack, X.509 v3 digital certificates with SHA516 signature hash, audit logs, Unsecure ports like HTTP and RTSP are disabled by default, uses RTSPS/SRTP for video streaming, UL 2900-2-3 Level 2 cybersecurity certified, Camera should have UL, EN, CE, FCC, NDAA, with IP 66 and IK10 impact protection 18 Supply and Installation of 5MP Outdoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE)Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. 19 Supply and Installation of 5MP Indoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, CE, FCC , UL certified. SD card support up to 2TB. 20 Supply and Installation of 12MP IR Panoramic camera with 1/2.3‑inch CMOS, 360° lens, Effective Pixels 3008 x 3008 (9 MP), 1 to 25 [30] fps, Sensitivity @30IRE: 0.15lux(color), 0.048lux(mono); 0 lux with IR; 20m IR; 120 dB WDR, Video compression H.264 (MP)/ H.265 (MP); M- JPEG, Electronic Day/Night, White Balance, Automatic Electronic Shutter, Backlight compensation, Intelligent Dynamic Noise Reduction (iDNR), Privacy Masking, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Camera Trainer (machine learning to train user specified objects), Built-in microphone(Integrated array with 3 digital MEMS audio sensors), Signal-to-Noise Ratio, Full-duplex / half duplex Audio Streaming, Memory card slot, 10/100 Base-T, ONVIF Profile S,G, M & T, clientside/cameraedge dewarping,IP66, NEMA 4X, IK10, PoE, CE,UL, FCC. 21 Supply and Installation of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz) Processor,16 GB DDR5,ECC UDIMM memory installed, 2U rack mount, 12 Trays: 3.5- inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port. Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Managment software In-built (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection , Sequencing selection, favorite view design.Dual authorization login,e Map support,ONVIF profile S,T complied,User management,Alarm management,SQL based database,LDAP support.Support of camera edge based analytics/server based analytics alarm triggering. Certifications UL,CB,CE,FCC,NDAA,BIS 22 Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON 23 Supply and Installation of Client Workstation with 21 Inch Monitor 24 RE-2AS Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex 25 RE-2AS BC Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x H x D) : 190 x 20 x 140 mm . Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x Hx D) : 190 x 20 x 140 mm 26 RE-2AS PTT Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. 27 RE-2AS MPE Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. 28 RE-2AS WMK Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet 29 RE-2AS 4L Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. 30 Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam anti microbial insulation (Nitrile Rubber) with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class O & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory adhesive bonding inline with LEED requirements & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3 wide Black Tape. Thermal Insulation - 9mm thick 31 Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with 10 mm thick acoustic insulation with Open Cell Foam Insulation - ArmasoundMicroban antimicrobial product protection withThermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive inline with LEED requirement.Acoustic Insulation - 13mm thick 32 Electrical panel with outgoing for 2nos. Of VRV ODU and IDU 33 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 34 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 36W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 9300 Candella . Bodymade of Die cast Aluminium.Effective delivered lumens 3000-3200, ,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 35 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 36 Supplying, fixing and commissioning of Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT,Body Made of Die Cast Aluminium30 deg Medium beam . Effective delivered lumens 1350-1400, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 37 Supplying, fixing and commissioning of Under Water Step Light IP 68 with RALfinish LED 5-8W, 3000K CCT, Medium beam.Effective delivered lumens 400- 600,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 38 Supplying, fixing and commissioning of Surface Mounted downlight IP 65 with RAL finish LED 20W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 39 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 40 Supplying, fixing and commissioning of Customized Deep mala Light IP65 with RAL finish LED 2-3W, 2400-2700K CCT, Diffused Beam° , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 80 including DALI driver.. Standard Warranty 5 Years. 41 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 3000 candella . Bodymade of Die castAluminium. Effective delivered lumens 1200-1400,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 42 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 43 Supplying, fixing and commissioning of Surface Mounted Adjustable Spotlight , Auminium Die Cast Body, IP 65 Ratedwith RAL finish LED 15W, 3000K CCT, Medium beam . Effective delivered lumens 1200-1300, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 44 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 3W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 40-50 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 45 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 5W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 150-200 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 46 Supplying, fixing and commissioning of Recessed Linear Grazer Die Cast Aluminium Body with SS Trim,LEDwattage to be 10-14W/m RGBW CCT Grazer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens: 500-600Real lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 47 Supplying, fixing and commissioning of Surface MountedLinear Grazer IP 67 ratedDie Cast Aluminium Body with adjustable Brackets, LED wattage to be 15W/m 3000K CCT Garzer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens:Real 1200lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 48 Supply, Installation, Testing and Commissioning ofAdjustable Gobo Projector Light , Body to be Made of Die cast Aluminium, Wattage of 180w Beam, 5200 lumens, 4 Gobo Modules , IK 08 CCT 7000k , Degree 15-45 deg Motorized Zoom, IP 66 rated. CRI >70. Driver Inbuilt DMX RDM Controlled. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer. 49 Supplying, fixing and commissioning of Post Top LuminaireIP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 50 Supply, Installation, Testing and Commissioning ofPole Mounted Adjustable Gobo Projector Light having Wattage of 40W and Delivered Lumens of 2500. Beam Degree 17-30., IP 65 rated with Pole mounting Bracket. CRI >70. Driver to be non dimmable and Integrated. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer.Including 4mtr. pole (procurred locally) 51 Supply, fabrication, and installation of a custom-made heritage chandelier of diameter 2000 mm and height 2000 mm, made from heavy-duty metal frame with antique brass / bronze / gold leaf finish as approved by the architect. The chandelier shall include precision-cut K9 / lead crystal elements in pendants, prisms, and beads, arranged in multi-layer form to create a grand decorative effect. Fixture shall be suitable for E14 / E27 LED lamps or integrated LED modules, providing warm white light (2700K–3000K) with CRI ≥ 90 and dimmable control.Suspension shall be with heavy-duty chain/rod system and canopy plate designed to safely carry the total load with 3× safety factor. All wiring shall be flame-retardant copper with proper earthing. The chandelier shall comply with IEC / IS standards and be supplied with shop drawings, finish samples, and load details for approval. Minimum warranty: 5 years. 52 Supply, Installation, Testing and Commissioning of Decorative Wall Light. Housing: IP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 53 Supply, Installation, Testing & Commissioning of International seeTouch QS Wallstation Insert 5 Button with Raise/Lower QSWE-5BRL 54 Supply, Installation, Testing & Commissioning of DALI Dimming controller; Controls 2 independent DALI links with up to 64 DALI ballasts per link. Can take care of Color Tunable fixtures. 4 groups of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSN-2UNVDAL- D 55 Supply, Installation, Testing & Commissioning of Switching module with 4channels, each channel with minium 5 amp rating with provisions of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSNE-4S 5230D module 56 The QSE-CI-DMX control interface allows zones on a to control DMX512-controlled devices Any zone can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB/CMY color-control The DMX channels (maximum of 32) are mapped to zones, and can be programmed as 1- channel lighting, 1-channel integration, or 3-channel RGB/CMY 57 Supply, Installation, Testing & Commissioning of central processor assembled processor with one/two configurable links and inbuilt BACnet for occupancy status. Each processor link can be configured to be a dimmer link, shade link, or dimmer power panel link. Processor accpets 220-240V, 1 phase, 2 wire, 10A feed, (throiugh power supply) Similar to Lutron Athena 58 Supply, Installation, Testing & Commissioning of Power Supply Unit for supply PDUs to Antenna devices Similar to Lutron QSPS-DH -1 -75Approved Makes :Lutron, Crestron, Pharos,Enlighten 59 Supply, Installation, Testing & Commissioning of Lighting control and monitor software, captures floor wise consumption, each event, Energy Reporting & monitoring per processor, 60 Supply, Installation, Testing & Commissioning of Lighting control BACnet softwares for BMS integration. This license for BACnet software enables a third-party building management system to control, monitor,and manage lights and shades in various areas on a processor. This license can also be used to share information between the control system and other control systems such as area occupancy, power usage, lighting state, etc. License required 1 per processor. 61 Supply of QS cable for power and data simialr to Lutron QS-CBL-LSZH Cable Adheres to CE standards for Low Smoke Generation (EN 60332-1-2), Halogen Gas Emission (EN 61034-2), and Flame Retardation (EN 60754- 1&2). • Five Conductors: Common – 0.75 mm2 (18 AWG) Power – 0.75 mm2 (18 AWG) MUX Data – 0.25 mm2 (22 AWG) _ Data – 0.25 mm2 (22 AWG) Drain Wire – 0.2 mm2 (24 AWG) Laying in suitable conduits to be done by Electrical contractor. 62 The scope of work includes the supply, installation, testing, and commissioning of asuitable Distribution Board (DB) box for mounting dimming and switching modules,complete with all necessary accessories such as enclosures, busbars, terminalblocks, MCBs, internal wiring, and supports, as per approved drawings andspecifications; the DB box shall be of robust construction, properly ventilated, factoryfinished, and designed to facilitate easy integration with the Lighting ManagementSystem, ensuring safe, reliable, and efficient operation after successful testing andcommissioning. 63 Programming of complete systemThe scope of work includes the complete programming, testing, and commissioningof the Lighting Management System (LMS), covering configuration of lighting zones,dimming levels, sensors, and schedules as per the approved control philosophy,integration with BMS/third-party systems if required, point-to-point and functionaltesting of all devices, fine-tuning and calibration, preparation of test reports and asbuilt documentation, and providing necessary training to client/end-user staff toensure the LMS is fully functional, compliant, and ready for handover. 64 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA confirming to CPCB IV Plus emmision compliant with output continuous rating. 3 Phase. 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed (liquid cooled multi-in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-5%, with performance class G2. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears,indicators connected with suitable zires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m. with suitable capacity DEF tank provided with first Filling of oil, diesel tank capacity not less than 385 Ltr etc. on provided M20 Grade CC Foundation and obtaning necessary aproval from electrical inspector if necessary. This DG Set is fiited in sound prof and whether proof Acoustic Enclosure asper CPCB IV plus emisison complaint as per specification no. GEN-DG
Contract Date: Jun 19, 2026 Contract Value : 1.28 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
10.
Heavy Industries and Public Enterprises #11319585 AOC
Tender For Electrical Works Required For Installation And Operation Of Radial Forging Plant Inside Msf, Ishapore.; 1 HV VCB PANEL - 1 (M & L): 5-Panel HT Switchboardto be connected with Cu busbars to the existing JYOTI make HT Panel at MRS-2 (3-nos.) & Pry-1 substation (2-nos.), Comprising of the followings: (Detailed specification is in ANNEXURE-1)HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker & copper busbars having rating upto 1200 Amp., rupturing capacity 350 MVA/40 KA, overload and earth fault protection, CTs, ammeter, PTs, voltmeter, MFM, Remote unit and 110VDC Power Bank for closing & tripping,complete in all respect. (Drawing to be approved before manufacturing). Make: JYOTI, SIEMENS. 2 HV VCB PANEL - 2 (M & L): 2-Panel HT Switchboardto be connected with Cu busbars to the existing SIEMENS make HT Panel at MRS-1, Comprising of the followings: (Detailed specification is in ANNEXURE-2)HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker & copper busbars having rating upto 1200 Amp., rupturing capacity 350 MVA/40 KA, overload and earth fault protection, CTs, ammeter, PTs, voltmeter, MFM, Remote unit and 110VDC Power Bank for closing & tripping,complete in all respect. (Drawing to be approved before manufacturing). Make: SIEMENS. 3 HV VCB PANEL - 3 (M & L): 6-Panel HT Switchboardto be connected with Cu busbars to the existing ALSTOM/SCHNEIDER make HT Panel at RF-1 substation, Comprising of the followings: (Detailed specification is in ANNEXURE-3)HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker & copper busbars having rating upto 800 Amp., rupturing capacity 350 MVA/40 KA, overload and earth fault protection, CTs, ammeter, PTs, voltmeter, MFM, Remote unit and 110VDC Power Bank for closing & tripping,complete in all respect. (Drawing to be approved before manufacturing). Make: SCHNEIDER. 4 HT CABLE (M & L): Supply & laying of XLPE insulated, screened, PVC bedded, galvanised steel strip armoured heavy duty electric power cable with aluminium conductor, 11000 volts grade, cross sectional area 300 sq.mm., 3 corefor (1) MRSto RF-1 S/S(two runs), (2) Tie link between MRS1 & MRS2, (3) Supply to T1 & T2, complete in all respect. Make: HAVELLS / GLOSTER / CRYSTAL / KEI. 5 HT CABLE TERMINATION (M & L): Supply & making of cable termination with termination-kit for 11 KV(E) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 sq.mm. Make: RAYCHEM, DENSON, 3M. 6 HT CABLE ST. TH. JOINT (M & L): Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm. Make: RAYCHEM, DENSON, 3M. 7 TRANSFORMER 2500 KVA (M & L): Supply and installation of Transformer, step-down, 11-6.6/0.433 KV complete, outdoor type, copper wound, resin cast dry type of capacity 2500 KVA complete in all respect. (Detailed specification is in ANNEXURE-4. Drawing to be approved before manufacturing). Make: SCHNIEDER / VOLTAMP / RAYCHEM / ABB. 8 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). INCOMER & BUSLINK ACB 4000 Amps, 4 Pole, 415 V, Manual Drawout type with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Incomer - 02 nos. & Buslink - 01 no. Make: SIEMENS / L&T / SCHNEIDER. 9 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING ACB 1600 Amps, 4 Pole, 415 V, Manual Drawout type with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 10 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING ACB 1000 Amps, 4 Pole, 415 V, Manual Drawout type with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 11 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING MCCB 400 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 400 Amp. Adjustable type (300 - 400Amps), Thermal Release with breaking capacity 50 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 12 LT PANEL SUBSTATION (M & L): LT PDB Panel 4000A, 4 Pole, 415 V, 50 Hz, indoor type, totally enclosedmetal clad switchgear & copper busbars, complete in all respect with the following items: (Detailed specification is in ANNEXURE-5. Drawing to be approved before manufacturing). OUTGOING MCCB 250 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 400 Amp. Adjustable type (200 - 2500Amps), Thermal Release with breaking capacity 50 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 13 LT WORKSHOP PANELS(M & L): One set of LT Panels 415v, 50 Hz, each comprising of steel enclosure, copper busbur, 1no (800A, 50kA) incoming MCCB, 6 nos.(250A, 36kA outgoing MCCB, 8 nos. (160A, 36kA) outgoing MCCB including standard protection and accesories. The total following items to be provided: (Detailed specification is in ANNEXURE-6. Drawing to be approved before manufacturing). INCOMING MCCB 800 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 800 Amp. Adjustable type (600 - 800Amps), Thermal Release with breaking capacity 50 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 14 LT WORKSHOP PANELS(M & L): One set of LT Panels 415v, 50 Hz, each comprising of steel enclosure, copper busbur, 1no (800A, 50kA) incoming MCCB, 6 nos.(250A, 36kA outgoing MCCB, 8 nos. (160A, 36kA) outgoing MCCB including standard protection and accesories. The total following items to be provided: (Detailed specification is in ANNEXURE-6. Drawing to be approved before manufacturing). OUTGOING MCCB 250 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 250 Amp. Adjustable type (200 - 250Amps), Thermal Release with breaking capacity 36 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 15 LT WORKSHOP PANELS(M & L): One set of LT Panels 415v, 50 Hz, each comprising of steel enclosure, copper busbur, 1no (800A, 50kA) incoming MCCB, 6 nos.(250A, 36kA outgoing MCCB, 8 nos. (160A, 36kA) outgoing MCCB including standard protection and accesories. The total following items to be provided: (Detailed specification is in ANNEXURE-6. Drawing to be approved before manufacturing). OUTGOING MCCB 160 AMP, 4P.(M & L): MCCB 4 Pole, 415 V, 160 Amp. Adjustable type (100 - 160Amps), Thermal Release with breaking capacity 36 KA, confirming to IS/IEC: 60947-2, complete with copper busbars, rotary handle & spreader terminals. Make: L&T / SIEMENS / SCHNEIDER. 16 LT CABLE 300 SQ.MM.(M & L): Supply& laying of PVC/XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 300sq.mm., 3.5core, confirming to IS:7098, complete in all respect. Make: CRYSTAL, GLOSTER, FINOLEX, POLYCAB, UNIVERSAL, HAVELLS. 17 JOINTING / TERMINATION OF LT CABLE 240 TO 300 SQ.MM. (M & L): Supply and fix cable jointing / Termination for 1.1 KV grade cable for complete with Jointing /Termination material (aluminium cable sockets, brass cable glands, PVC insulation tapes etc.)and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 240 to 300 sq mm., complete in all respect. 18 LT CABLE 185 SQ.MM.(M & L): Supply& laying of PVC/XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 185sq.mm., 3.5core, confirming to IS:7098, complete in all respect. Make: CRYSTAL, GLOSTER, FINOLEX, POLYCAB, UNIVERSAL, HAVELLS. 19 JOINTING / TERMINATION OF LT CABLE 120 TO 185 SQ.MM. (M & L): Supply and fix cable jointing / Termination for 1.1 KV grade cable for complete with Jointing /Termination material (aluminium cable sockets, brass cable glands, PVC insulation tapes etc.)and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 120 to 185 sq mm., complete in all respect. 20 AIR CIRCUIT BREAKER 3200A (M & L): ACB 3200 Amps, 4 Pole, 415 V, Manual Drawout type to be Retrofitted in the existing LT Panel (HT shop) with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 21 AIR CIRCUIT BREAKER 1000A (M & L): ACB 1000 Amps, 4 Pole, 415 V, Manual Drawout type to be Retrofitted in the existing LT Panel (HT shop) with microprocessor release, 50 kA with overload, short circuit and earth fault protection, copper busbars, CTs, ammeter, voltmeter and MFM. Make: SIEMENS / L&T / SCHNEIDER. 22 DISMANTLING & REFIXING OF LT AIR-BREAK (SWITCH) DB (L): Dismantling & refixing of LT AIR-BREAK (SWITCH) DB with accessories on MS angle with nuts, bolts etc. 23 EXCAVATION SOIL: Excavation of hard/dense soil over areas, n exc 1.5 m deep in cable trenches and getting out. 24 REFILLING OF SOIL: Returning, filling in, inc spreading, levelling, watering and well ramming of excavated soil for cable trenches. 25 SAND FILLING (M & L): Sand filling under cable trenches over laid cables. 26 GI CABLE TREY AND SUPPORTING COLUMN (M & L): Supply, fixing & febrication of rolled GI channel, angle, sheet, plates, rods and flats of different sizes for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. with Fe-410-W (Gde E-250) quality-B for fixing of prefebricated cable trays / supporting column of different sizes, supports etc., complete in all respect. The structure shall be hot dip galvanized with minimum thickness of coating not less than 80 microns. Galvanization shall conform to IS-2629, 4759 & 4736 as applicable. 27 REINFORCED CEMENT CONCRETE (M & L): Reinforced cement concrete (nominal mix)in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass cement concrete ofType B0 1:2:4 Type B1 1:2:4 (12.5mm graded (20 mm graded aggregate)concrete, complete in all respect. 28 FORMWORK TO CONCRETE (M & L): Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete in all respect. 29 TMT BAR STEEL REINFORCEMENT FOR CONCRETE (M & L): Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed)6mm to 8mm dia or securing with clips, complete in all respect. 30 STEEL PIPE (M & L): Galvanised Steel Tubing (Piping), medium grade of bore size 100mm, including all fixing & fitting (MS clamps, flats) laid across drains, roads, fixing complete with all respect. Make: TATA, JINDAL. 31 DEMOLITION OF BRICKWORK & MASONRY (L): Demolition of Brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillers, etc. 32 CEMENT CONCRETING: Cement concrete in foundation, filling and mass concrete Type B2 1:2:4 (40mm graded aggregate), for repairing the demolished brick or masonery work on roads, hard standings & footpaths including tile-soaling, complete in all respect. 33 BRICK FOR CABLE SUPPORT (M&L): Supply & laying of Continuous brick edging; with width equal to the depth of the brick, laid dry, on edge With burnt clay bricks of sub class B, old size on two sides of laid cable. 34 BRICK WORK(M & L): Supply & making of Brick work with subclass B bricksbuilt in cement mortar 1:4 for making of walls & cable trench, complete in all respect. 35 CEMENT PLASTERING(M & L): Supply & making of Cement plastering 10mm thick on fair surfaces of brickwork or concrete surface, in cement mortar 1:4 (with net finish on floor), complete in all respect. 36 EARTH CONTINUITY CONDUCTOR (L): Supply & Fixinging of Earth ontinuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6mm galvanised iron strip. 37 EARTHING (M & L): Supply & making of Earthing for SS LT Switchgear, complete with galvanised steel earth plate electrode, 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge not less than 1.5 meter below ground level, connected with galvanised iron 32 x 6mm strip as earthing lead (upto 7.5m) by means of bolts, nuts, check nuts & washers of GI or GS all as shown in Plate No. 5 to the earthing test point all as specified and indicated including testing on completion. This includes making of pit, providing CI cover, funnel with watering pipe, wire mesh and GI earth lead protection pipe. 38 MS CHEQUERE PLATE: Supply & fixing of Rolled mild steel Plates (Chequered of 8 mm. thickness) [Fe 410-W (Gde-E- 250) quality-A] channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with 2-coat of red oxide primer for cable trench cover. 39 GI CHANNEL/ANGLE/FLAT (M&L): Supply, fixing & febrication of rolled GI channel, angle and flat, [Fe 410-W (Gde-E- 250) quality-A] fixed independently for fixing of LT PDB`s and making & fixing of cable trays / cable cover supports of different sizes, supports etc., complete in all respect. 40 UG CABLE 25 SQMM (M&L): XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm, 3½ core, complete in all respect. 41 JOINTING / TERMINATION OF LT CABLE 16 TO 35 SQ.MM. (M & L): Supply and fix cable jointing / Termination for 1.1 KV grade cable for complete with Jointing /Termination material (aluminium cable sockets, brass cable glands, PVC insulation tapes etc.)and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 16 to 35 sq mm., complete in all respect. 42 SUBMAIN WIRING (M&L): Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in existing surface/recessed as required of size 2x2.5 sq. mm + 1x1.5 sq. mm earth wire in steel conduit, junction box, complete in all respect. Make: MESCAB, HAVELLS, POLICAB, KEI, FINOLEX, ANCHOR. 43 160A MCCB WITH ENCLOSURE(M&L): Complete with the following in all respect. MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA to be fixed in the sheet GI steel enclosure. 44 160A MCCB WITH ENCLOSURE(M&L): Complete with the following in all respect. Sheet GI steel enclosure of size 2nos.x 0.5m x 0.5m x 0.3m, and spreader terminal, complete in all respect. Thickness of sheet in1.60 mm. 45 STEEL METAL ENCLOSURE FOR MCB DB (M&L): Supply, fixing & connection of Sheet metal enclosure for DB`s MCB to be used, Three pole and neutral, 4-way, 415 V, double door, complete in all respect. Make: SIEMENS / L&T / SCHNEIDER. 46 MINIATURE CIRCUIT BREAKER 5 TO 32A SP (M & L): Supply and fixing 240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissionin, complete in all respect. Make: SIEMENS / L&T / SCHNEIDER. 47 POINT WIRING (M&L): Poing Wiring with copper conductor cables FRLS in stove enamelled Steel Conduit steel conduit for One light point or one fan point controlled by one switch with 2.5 sq. mm size PVC single core cables including earth wire, junction box, complete in all respect. Make: MESCAB, HAVELLS, POLICAB, KEI, FINOLEX, ANCHOR. 48 OH HIGH BAY LIGHT FITTING, 150W(M & L):Supply and fixing LED Overhead High Bay light fitting 1x150 Watt, IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED Overhead High Bay light fixtures driver, holders, connector etc. Complete with all accessories prewired and including fixing on overhead cross beam, connecting up with three core flexible copper conductor cable with suitable size, complete in all respect. MAKE: HAVELLS / PHILIPS / SURYA 49 SECURITY LIGHT FITTING, 90W(M & L):Supply and fixing LED Street light fitting 1x90 Watt, IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED Street light fixtures driver, holders, connector etc. Complete with all accessories prewired and including fixing on overhead column with GI bracket, connecting up with three core flexible copper conductor cable with suitable size, complete in all respect. MAKE: HAVELLS / PHILIPS / SURYA 50 AIR CIRCULATOR(M & L):Supply and fixing IndustrialHeavy Duty pedestal Air Circulator Fan, 30 (750 mm sweep, 415 VAC, 50 Hz, 1440 rpm, delivery-1700 CFM, 28900 m3/hr CI base, MS pipe, MS wire guard, Al. alloy casting, 4 wing blade motor with chord & MCB with enclosure, complete with paint.MAKE: POWER VENT/BAJAJ/CG/CALCUTTA FAN/ALMONARD 51 LOCK, 65MM (M & L):Brass 4 Lever Padlock of size 65mm for steel doors & rolling shutters. 52 SUBSTATION SCADA FOR HT & LT POWER DISTRIBUTION (M & L):Design, engineering, supply, installation and commissioningof MSF SCADA Systems for HT & LT power distribution as per enclosed ANNEXURE-7. complete in all respect.
Contract Date: Jun 26, 2026 Contract Value : 6.13 Crore
Government Departments No of Bidders 4
West Bengal View Result →
11.
Drinking Water Supply and Sanitation #11312834 Technical Bid
Tender for Online Multi::Parametric Cod, Bod, Tss And Ph Analyzer With Gprs Data Transmission To Cpcb/Spcb Portal Supplied With Spectrophotometry Sensor (Cod, Bod, Tss), Ph::Lyser (Ph) And Con::Cube Terminal Make: S::Can, Austria , Electromagnetic Flow Meter Upto 20 Inch Make: Badger/Abb Description Product Type: 1M - M1000 Certification: A - General Safety/Purpose Meter Size: 180 - 18 / Dn450 Process Connections: Faa - Asme: Class 150 Flg: Rf Base Material: C1 - Carbon Steel Liner Material: P - Ptfe Electrodes : A - Hastelloy C-22 (Standard / Measuring, Empty Pipe And Grounding) Grounding Rings: X - No Gnd Rings Meter Lay Length: S - Standard Transmitter: Sa - Sensor Mount: Local Dsp: Al Encl: Ip67 Power Supply: Ab - 9-36V Dc Hardware: C - M20 Thrd: Poly Cable Glands Junction Box: X - None Remote Cable Length: Ww - None Input/Output Channel: Dba - Std Input/Output Communications: R - Std Comms Wiring Method: Xx - None Std Programming: Ea - Standard (Default Metric Units) Testing And Tagging: F - 0,3%: 3-Point: Factory Calibrated , Operation And Maintenance During Defect Cum Liability Period , Operation And Maintenance For First Year After Defect Cum Liability Period , Operation And Maintenance For Second Year After Defect Cum Liability Period , Operation And Maintenance For Third Year After Defect Cum Liability Period , Operation And Maintenance For Fourth Year After Defect Cum Liability Period , Operation And Maintenance For Fifth Year After Defect Cum Liability Period
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
12.
Public Administrative Department #11310503 AOC
Tender for Supply Of Electrical Materials For The Repair And Maintenance Of Street Light , Details , T-5 Power/Energy Saver 2X24w Choke , T-5 Power/Energy Saver 24W Ftl Tuberod , 2X24 T5-Holder , T5 Power Saver 2X24 Fixture Acrylic Transparent Cover , T5 Power Saver 4X24 Fixture Acrylic Transparent Cover , 150W Hpsv Choke , 150W Hpsv Lamp , Capacitor 33Mfd 250Vac 50 Hz , Electronic Ignitor Suitable For 150W Hpsv Lamps , 150W Holder (Porcelain) , Led Driver 50W Bis Certified , Led Mcpcb Plate 60W , Led Mcpcb Plate 50W , Led Mcpcb Plate 150W , Supplyingof Isi Marked And Approved Make Of Moulded Case Circuit Breaker(Mccb) Suitable For 3Phase,3Pole,50Hz,415 Volts, Ac Supply With Respective Interrupting Capacity(Ka) At 415 Volts Cited Against Their Range Standard Conforming To Is - 8828: 8.1Mccb With Breaking Capacity 25 Ka At 415 V: Current Rating -125 Amps & 70% -100% Adjustable , Supply Of Sovp Device Should Have Single High Capacity Varistor In The L-N Plug And Encapsulated Spark Gap For N-Pe, L-N Sovp Should Have A Rated Voltage Of Minimum 320V Ac To Handle Indian Power Supply Conditions. Sovp Should Have Visual Indication On Replaceable Varistor And Spark Gap Modules As Well As A Potential Free Contact On The Socket For Remote Indication. Sovp Device Should Be Wired Up As Per Tt Configuration Of Wiring In Accordance With En 61643-11 Standards. Both The L-N And N-Pe, Spds Should Be Rated For Handling 30Ka Of Nominal 8/20 Μs Surge Current.: Sovp For Pole Light Sub Feeder Panels - Type 2 Pluggable Spd 3+1, Rating L-N/N-Pe Uc 255/320 V In 30/60Ka Ka, Lmax 30Ka/60 Ka, Up 1.5Kv , Supplying Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker(Mcb)Ofcseries Suitable For 240/415Volts,50Cycle,10 Ka Value Ac Supply Confirming To Is:8828:1996,Iec:60898 :2002 But Without Enclosures: Single Pole 63 Amp. , Astronomical Timer With Dst Feature , Contactor 3 Pole 90 annual periodical maintenance 50Hz 415Volts With No-Nc Contacts , Tpn Connector 150A , Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar,Neutral Bar,Earth Bar & Two Earth Terminals Etc. Complete As Per Is:13032 (Exclusive Of Mcb & Isolator): 8 Way Double Door , Supply Of Sovp Device Should Have Single High Capacity Varistor In The L-N Plug And Encapsulated Spark Gap For N-Pe, L-N Sovp Should Have A Rated Voltage Of Minimum 320V Ac To Handle Indian Power Supply Conditions. Sovp Should Have Visual Indication On Replaceable Varistor And Spark Gap Modules As Well As A Potential Free Contact On The Socket For Remote Indication. Sovp Device Should Be Wired Up As Per Tt Configuration Of Wiring In Accordance With En 61643-11 Standards. Both The L-N And N-Pe, Spds Should Be Rated For Handling 30Ka Of Nominal 8/20 Μs Surge Current.: Sovp For Pole Light - Type 2 Pluggable Spd 1+1, Rating L-N/N- Pe Uc 230/400 V In 5 Ka, Imax 10 Ka, Up 1.2Kv , Led Batten Tubelight 20W , Supplying Of Approved Make Tpn Mcbdb Metal Double Door With Provision For Fpmcb/Isolator/Rccb/Rcbo As Incomer And Sp Mcbs As Outgoing Inclusive Of Busbar,Neutral Bar,Earth Bar & Two Earth Terminals Etc. Complete As Per Is:13032 (Exclusive Of Mcb & Isolator ): 8 Way (8+24) , 8 Sq.Mm Multistrand Pvc Insulated Copper Wire Bundle 90Mtr , 1.Sq.Mm Aluminium Single Core Wire Bundle Of 100Mtr. Isi Marked , Xlpe Insulated Power Cable( Conforming Is-7098 Part-1) 1100 Volt Grade 2-Core Isi Marked With Alu. Stranded/Solid Conductor: 16 Sq.Mm Unarmoured , Xlpe Insulated Power Cable( Conforming Is-7098 Part-1) 1100 Volt Grade 4-Core Isi Marked With Alu. Stranded/Solid Conductor: 16 Sq.Mm Unarmoured , Xlpe Insulated Power Cable( Conforming Is-7098 Part-1) 1100 Volt Grade 1-Core Isi Marked With Alu. Stranded/Solid Conductor: 25Sq.Mm Unarmoured , Wooden Ladder 21Ft , Toolkit Set Consisting Of Different Sizes L-Keys, Screw Drivers, Testers And Plier Set. , Taperoll Box Consisting Of 30Pcs (Conforms To Is: 7809 (Part 3, Sec 1),Self Extinguishing,Protects From Electrolytic Corrosion,Excellent Water Resistance,Suitable For Primary Insulation Up To 440V)
Contract Date: Jun 29, 2026 Contract Value : 60,699
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
13.
Educational and Research Institute #11309731 AOC
Bids Are invited for Raw Material White Board Marker - Whiteboard Markers Black, Blue, Red And Green 4.43 Mm Bullet Tip Non-Toxic Smooth Writing Easy Wipe , Cleaning Liquid 50Ml - Liquid Cleaning Kit For Laptop For Laptops Computers, Gamingm, Mobiles , Photo Copy Paper A4 - Copier Paper A4 Size 70 Gsm 500 Sheets White Paper, 1 Ream For Laserjet Inkjet Printer Fast Drying Both Side Print Eco Friendly Color , Rj 45 Connector - Rj45 Connector Module Plugs , Mouse Usb Product - Comfort Wired Usb Mouse 3 Button 1000 Dpi Optical Sensor Plug And Play For Windows Mac Black , Keyboard Usb Product - Wired Usb Keyboard Plug Play 105 Button Mouse 1000 Dpi High Precision Advanced Optical Sensor , Cat 6 Cable 305Meter - Colour Gray Connector Gender Male To Male Item Weight 10570 Grams Item Length 305Meter , Stapler 10No Small - Staples Combo Standard Stapler With Quick Loading Mechanism Sturdy Durable For Long Time Use Color May Vary Pack Of 1 , Remote Battery Aaa - Aaa Battery Duracell Devices Clock Toy Remote , Battery Clock Aa - Aa Battery Duracell Devices Clock Toy Remote , Cd - A Compact Disc Cd Is A Digital Optical Disc Data Storage , Dvd - A Compact Disc Dvd Is A Digital Optical Disc Data Storage , Usb-Hub Bus - Ultra Slim Multiport Type C Hub To 1Xusb 3.0 And 3Xusb 2.0 Ports , Vga Cable 1 To 2 - Cable 1 Male Vga To 2 Female Vga Splitter Cable For Laptop, Television, Personal Computer , Curtains - Size 4X6 Silky Cloth , M.S.Flat 50X12mm - Ms Flat Rectangular Ms Flat, For Industrial 50X12mm , M.S.Flat 100X10mm - Ms Flat Rectangular Ms Flat, For Industrial 100X10mm , M.S.Flat 50X8mm - Ms Flat Rectangular Ms Flat, For Industrial 50X8mm , M.S. Electrode 2.5Mm - Welding Rod E6013 2.5 X 350Mm (Mse011) Isi Grade Mild Steel Electrode Rutile Coated Arc Welding Rods For Ac/Dc Easy Strike, Smooth Bead, Low Spatter General Fabrication And Repair , M.S Sheet 3 X 8 X 2.5Mm - Ms Sheet 2.5 Mm Rectangular Mild Sheet For Industrial , M.S Sheet 4 X 8 X 3Mm - Ms Sheet 3 Mm Rectangular Mild Sheet For Industrial , Welding Machine Output Copper Leads 35Mm - Isi Welding Cable 35 Sq.Mm Flexible Isi Certified Copper Welding Cable For Workshop And Fabrication Use , Pvc Gang Box 4X8 Modular - Modular Surface Gang Box, White 4X8 , Pvc Gang Box 4X10 Modular - Modular Surface Gang Box, White 4X10 , Multistandard Copper Wire 4Mm - Pvc Copper Wire 4Mm Pro Fr Electrical Wire, 90 Meter Fire Resistant Single Core Pvc Insulated Pure Copper Wire, Anti Rodent Anti Termite Flexible Wire For Connections Black , Multistandard Copper Wire 4Mm - Pvc Copper Wire 4Mm Pro Fr Electrical Wire, 90 Meter Fire Resistant Single Core Pvc Insulated Pure Copper Wire, Anti Rodent Anti Termite Flexible Wire For Connections Red , Bar Magnet - Enhancing Efficiency And Precision In Manufacturing Processes 4 Inch , Carbon Resitor 01 K - Tolerance 1K Mr Ohm Mf Through Hole Resistors Axial Lead , Diode 1N 4007 - Diode In4007 Passive, Two Terminal Electrical Components That Limit Or Regulate The Flow Of Electric Current In A Circuit , Mcb 63 Tpn With Box - Mcb Single Pole 63 Triple Pole Mcb With Box Isi Marked , Steel Screw 15Mm 100Nos - Screw 15Mm Steel Screw Paster Boards Solid Stainless , Pvc Rawal Plug 3.5Mm - Rawl Plug Heavy Duty Plastic Rawl Plugs Durable Expansion Anchors For Plasterboard, Masonry, Brick And Concrete Wall Fixings For Screws , Wooden Screw 75Mm 100Nos - Screw 75Mm Fixing Wood, Plywood, Paster Boards Solid Stainless , Pvc Cable Clip 6Mm - Pvc White Cable Clip 6Mm , Pvc Cable Clip 10Mm , Pvc Cable Clip 20Mm , 4 Core 2.5Mm Armoured Cable - 4 Core 2.5Mm Armoured Cable Lt Power Cable Insulation Material Xlpe Conductor Material Aluminum Number Of Cores 4 Core Application Power Cable Voltage 1100 V Current Rating 34 To 418 , Pvc Casing Caping 1 Inch 6Ft Length - Pvc Casing N Caping, For Electric Wire Installation 3M , Sand Paper Zero Number - Sanding Paper Emery Paper Sand Paper , Led Bulb 18W - Led Bulb 18W Electric High Glo Led Bulb 18W, B22d Cap, 6500K , Solar Torch - Solar Torch Electric High Glo Led Bulb 18W, B22d Cap, 6500K , Seek Jadhu - Jhadu Seek Jhadu Plastic Wet And Dry Brush (White) , Table Cloth Size 5X3 - Machine Washable Rectangle Tablecover For Office Table , Kachra Bag - Leak Proof And Tear Resistant Trash Bags For Kitchen Home And Commercial Use Dustbin Bags For Dry And Wet Waste With Free Check Duster Cloth -Black , Register 2 Quire - Register 2 Quire, Pages C Ruled Single Line Register For Office Record Keeping , Register 4 Quire - Register 4 Quire, Pages C Ruled Single Line Register For Office Record Keeping , Chalk White - Chalk White A Soft, Porous, Sedimentary Carbonate Rock Primarily Made Of Calcium Carbonate , Duster - Wooden Duster For White Boards, Glass Boards And Chalk Boards , Stepler 24X6 Big - Staples Combo Standard Stapler With Quick Loading Mechanism Sturdy Durable For Long Time Use Color May Vary , Marker Ink 15 Ml - White Board Marker Ink - 15 Ml Suitable For White Board Surface School Stationery Easily Refill Bold Color Smudge Proof Quick Drying , Bill Register - Bill Register 70 Gsm Paper With Hard Binding Cover For Long Durability , Batten Holder 05 - Batten Type, White, Isi Certified, Ideal For Ceiling/Wall Use With Standard , Angle Holder 05 - Angle L Holder Fancy Type 240V White , Pendent Holder 05 - Pendant Bulb Holder For Wall, B22 Batten L Holder For Led/Electric Bulb For Home (White) , Pvc Aluminium Wire 2.5 Mm Single Strand - Aluminium Wire Electric Cable Heavy Duty 2.5Mm 2 Core Aluminium Cable For Electrical Fittings , Kit - Kat Fuse 100A - 100A 415 Volt Ac Porcelain Fuse Units (Kitkat Fuse) , Winding Wire Copper 32 Swg - Enameled Copper Wire - 32 Gauge (0.27 Mm Diameter) - 99.9% Pure Copper Wire - Winding Wire , Winding Wire Copper 35 Swg - Enameled Copper Wire - 35 Gauge (0.27 Mm Diameter) - 99.9% Pure Copper Wire - Winding Wire , Winding Wire Copper 36 Swg - Enameled Copper Wire - 36 Gauge (0.27 Mm Diameter) - 99.9% Pure Copper Wire - Winding Wire , Cotton Winding Tape - Cotton Tape For Winding Insulation And Multipurpose Use , Winding Sleev Umpire 01 No - Fiberglass Insulation Sleeve 1Mm Class H 180Degree C Heat Resistant Electrical Insulation Tube Braided Glass Fiber Sleeve For Motor Winding Transformer And Wire Protection , Winding Sleev Umpire 02 No - Fiberglass Insulation Sleeve 2Mm Class H 180Degree C Heat Resistant Electrical Insulation Tube Braided Glass Fiber Sleeve For Motor Winding Transformer And Wire Protection , Winding Sleev Umpire 03 No - Fiberglass Insulation Sleeve 3Mm Class H 180Degree C Heat Resistant Electrical Insulation Tube Braided Glass Fiber Sleeve For Motor Winding Transformer And Wire Protection , Winding Sleev Umpire 04 No - Fiberglass Insulation Sleeve 4Mm Class H 180Degree C Heat Resistant Electrical Insulation Tube Braided Glass Fiber Sleeve For Motor Winding Transformer And Wire Protection , Winding Sleev Umpire 05 No - Fiberglass Insulation Sleeve 5Mm Class H 180Degree C Heat Resistant Electrical Insulation Tube Braided Glass Fiber Sleeve For Motor Winding Transformer And Wire Protection , Sand Paper 00 To 01 No - Sandpaper, 9 X 11 Inches, Silicon Carbide, Ultra Fine Grit 60, Foam Backed, Compatible With Sanding Block, Suitable For Metal, Wood, Plastic , Winding Paper Millinex Paper - Insulation Paper Sheet Class F 155Degree C Electrical Insulation Paper Flame Resistant High Dielectric Aramid Sheet For Motor And Transformer , Lock 55Mm - Lock 55Mm Combinations Steel Body Hardened Shackle 8 Brass Levers Made In India Padlock 3 Silver Keys , Coolent - Hybrid Tech Antifreeze Coolant For Bikes Ready To Use Radiator Fluid, Prevents Overheating Corrosion, Long-Lasting Engine Protection , Gardening Pipe 1Inch - Gardening Pipe 1Inch Heavy Duty 3 Layered Braided Pipe 30 Meter Long Water Hose Pipe Pvc Braided Pipe Green Garden Outdoors Pipes With Hose Connector , Saddle Patti - Plastic Saddle Cl 25Mm , Metal Mcb Channel Patti - Mounting Rail 35Mm X 7.5Mm Slotted Galvanized Steel Channel For Electrical Panels, Terminal Blocks, And Mcb Mounting , Pvc Clip 6Mm - Pvc White Cable Clip 6Mm , Pvc Flexible Coper Wire 4Mm - Pvc Flexible Coper Wire 4 Sqmm 90 Meter Copper Wire Hrfr Heat Resistant Flame Retardant Lead-Free Cable Low Smoke Halogen-Free Wire For Home And Industrial Electrical Wiring , Pvc Flexible Coper Wire 1.5Mm - Pvc Flexible Coper Wire 1.5Mm Electrical Wire, 90 Meter Fire Resistant Single Core Pvc Insulated Pure Copper Wire, Anti Rodent Anti Termite Flexible Wire For Connections (Black , Screw 4Inch - Ms Screw 6 X 100 Mm (4 Inch) , Soldering Iron 65Watt - Heavy-Duty 65 Watts Soldering Iron With Pvc Wire And Copper Tip , Upvc Pipe 3X4inch - Upvc Water Pipe Of Size 3X4inch , Upvc Elbow 3X4inch - Upvc Elbow 3X4inch Fittings Elbow 90 Degree 3Inch White , Upvc Tee 3X4inch - Plain Upvc Tee For Plumbing Pipe 3X4 Inch , Upvc Solvent 200Grm - Pvc Heavy Body Solvent For Pvc Larger Dia Pipes And Fittings , Taflon Tape - Plumbing Gas And Thread Sealing Ptfe Leak-Proof, Multi-Purpose Sealant Tape , Pvc Cl Pipe 3X4inch - Pvc U Shaped Pipe Cl S With Flat Nail Ivory Wire And Tube Holder Durable Pipe Clip , Upvc Union 3X4inch - Upvc Union Pipe Fitting, 1.9 Cm 3X4 Inch, White , Upvc Socket Adapter 3X4inch - Upvc Reducing Socket 3X4 Inch To 1X2 Inch White , Upvc Reducing Adapter 1Inch To 3X4inch - Upvc Reducing Socket 3X4 Inch To 1X2 Inch White , Upvc Brass Elbow 3X4inch To 1X2inch - Upvc Brass Elbow For Pipe Fitting 3X4 X 1X2 Inch , Upvc Ball Valve 3X4inch - Upvc Compact Ball Valve 3X4inch 25Mm , Upvc Tank Adapter 3X4inch - Upvc Socket Tank Connector 3X4inch , Steel Tap 1X2inch - Stainless Steel Long Body Taps For Bathroom And Kitchen Taps With Chrome Finish And Quarter Turn Fitting , Water Tank 2000Lit 6 Layer - Water Tank 2000 Lit Six Layer Water Tank 2000 Liter Capacity Blow Mould Tanks Food Grade Antibacterial, Uv And Heat Resistant Tank Hdpe Material White Color , Water Tank 1000Lit 6Layer - Water Tank 1000 Lit Six Layer Water Tank 1000 Liter Capacity Blow Mould Tanks Food Grade Antibacterial, Uv And Heat Resistant Tank Hdpe Material White Color , Upvc Pipe 1Inch - Upvc Water Pipe 1 Inch , Upvc Elbow 1Inch , Upvc Tee 1Inch , Upvc Socket Adapter 1Inch , Upvc Union 1Inch , Pvc Cl Pipe 1Inch , Upvc Tank Adapter 1Inch , Upvc Ball Valve 1Inch , White Board 4X6 - Whiteboard Drywipe Magnetic With Pen Tray And Aluminium Trim, 4 Ft X 6Ft , Casing Patti 2Inch - Cassing Patti 2Inch Designed For Surface-Mounting Electrical Wires , Big Bucket - Big Bucket Industries Unbreakable Strong Plastic Bathroom Bucket 12 Ltr , Wooden Beat 3X4inch Half Round - Half Round Wooden Moulding Beat Patti For Furniture Rack Side Fitting , Nails 1Inch - 1Inch Steel Concrete Nails , Ms Round Bar 30Mm - Ms Round Bar 30 Mm Black Mild Steel Round Bar , Ms Round Bar 40Mm - Ms Round Bar 40 Mm Black Mild Steel Round Bar , Ms Round Bar 45Mm - Ms Round Bar 45 Mm Black Mild Steel Round Bar , Ms Round Bar 50Mm - Ms Round Bar 50 Mm Black Mild Steel Round Bar , Ms Round Bar 60Mm - Ms Round Bar 60 Mm Black Mild Steel Round Bar , Ms Round Bar 65Mm - Ms Round Bar 65 Mm Black Mild Steel Round Bar , Mobile Oil 40No. - Mobile Oil 40No. Engine Oil For Diesel Engine , Cutting Oil - Cutting Oil Water Soluble Cutting Oil , Power Saw Blade 1Inxh X 14Inch - Power Hexa Blade (14Inchx1inchx0.050Inch) Hss Bimetal Power Hacksaw Blade , Hand Hacksaw Blade 1X2x12inch - Hand Hexa Blade 1X2inchx1x2inchx0.050Inch Hss , Emery Paper 80No. - Emery Paper 80No. Coarse Brown Sandpaper For Wood, Metal, Walls And Diy Finishing Medium Size, Emery Material, Paper Backing , Emery Paper 100No. - Emery Paper 100No. Coarse Brown Sandpaper For Wood, Metal, Walls And Diy Finishing Medium Size, Emery Material, Paper Backing , Wire Bursh 4Inch - Steel Wire Brush With Plastic Handle, 5 Rows , Chalk Clolour - Color Chalks Limestone Slate Pencils Chalk Piece Full , Grease - Grease Long Lasting Lubricant For Cars, Buses, Trucks, 2 Wheeler, 3 Wheeler, Agriculture And Construction) , File Card - Abrasive File Card With Wooden Handle , Engine Oil - Engine Oil 20/40No. Engine Oil For Diesel Engine , Service Cable 3 Core 4Mm Flat , Weight Machine 500Kg. Platform Size 2X2 - Electronic Platform Weighing Scale 600X600mm Mild Steel 500Kg Capacity, 50G Accuracy Oiml R76 Compliant, Iso Certified Digital Weight Machine For Shop, Warehouse, Industrial Use , Ladder 20Ft Foldable Type - Aluminum Wall Support Extension Ladder , Router 4G Lte Wireless Dongle , Switch 8 Port 1000Mbps Gigabit - 1000Mbps Full Duplex 8 Port Gigabit Switch Hub Lan Gigabit Ethernet Desktop Network Switches Black Total Quantity : 4361
Contract Date: Ref. Documents Contract Value : 11.85 Lakh
Boards / Undertakings / PSU No of Bidders 4
Madhya Pradesh View Result →
14.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
15.
Heavy Industries and Public Enterprises #11255514 AOC
Bids Are Invited For 094100031Transformer For Fault Current Monitoring, 80Mm 751031 , 095000346 Over Voltage Protection Dehn Venci, Typ1 Plus 2, 230V Ac, Remote 646293 , 091700350 Load-Break Switch Intermediate Installation, 3Pol., 40...1 666318 , 091700351 Main Switch Kit Grey For 3Va20,21,22 666326 , 091700352 Terminal Cover For 3Va20,21,22 666329 , 094500153 Motor Protection 3Rv2 7-10A Without Help Switch, Cagecl Amp 580810 , 094500154 Motor Protection Helpswitch 1N0 Plus 1Nc, Cageclahp 580818 , 094500155 3 Phase Busbar For 3 X 3Rv2, Extension, Cageclamp 582939 , 094500156 Connector For 3Rv2, S00, Cageclamp 582942 , 094500157 Motor Pr0tection 3Rv2 1, 4-2A Without Helpswitch, Cageclamp 580803 , 094500158 Wire Protection 5Sy4 Typ C, 6A With0ut Helpswitch 507085 , 094500159 Wire Protection Helpswitch For 5Sy4 433799 , 095000347 Current Protection Fuse 2-Pin., C2a, 230V, 30Ma 697828 , 094500160 Trafo Protection 3Rv24 5,5-8,0A Without Helpswitch, Cageclamp 580816 , 094200076 Transformer 2500Va, Pri 208-550 Vac, Sec 115-230 Vac 700414 , 092800394 System Lamp, 530Mm, 24V Dc, Led 594023 , 092800395 Connection For System Lighting Led 3M, Door Contact Switch 587884 , 091900048 Earthing Contact S0cket, Grey, Push-In, Germany 657183 , 094500161 Motor Protection 3Rv2 2,2-3,2 A Without Helpswitch, Cageclamp 580805 , 094500162 3 Phase Busbar For 2X 3Rv2, Infeed Left, Cageclanp 582938 , 313000345 Power Supply Sitop 3X320-575Vac-24 Vdc-40A 562833 , 094500163 Motor Protection 3Rv2 5,5 8A Without Helpswitch, Cageclamp 580809 , 094900070 Emergency Stop Butt0n, Signum 22Mm, Illuminated 641327 , 094900071 Holder Metal, Sirius Act 22Mm 641350 , 094900072 Switch Block, Sirius Act 22Mm, 1Nc, Front Mounting, Cagecl 641352 , 094900073 Switch Block, Sirius Act 22Mm, 1No, Front Mounting, Cagecl 641351 , 092800396 Led Module White, Sirius Act 22Mm, 24 Vdc, Frontmount, Cage 641360 , 092800397 Yellow Underlay Label For Emergenc, Sirius Act, Empty, 75M 641372 , 091600364 Workinghour Counter Ts Rail, 7 Digit Lcd, Without Reset, 2 628678 , 093600278 Fault Current Monitoring 0,03 40A, 2W, Cageclamp 751030 , 091700353 Power Relay 3Rt2-S00 5,5Kw, 3H, 1N0, 24 Vdc, Cageclamp 580669 , 091700354 Power Relay 3Rt2-S00 3Kw, 3H, 1N0, 24 Vdc, Cageclahp 580664 , 096600108 Screening Link Varist0r Without Led, 3Rt2- S00, 24-70 Vdc 580691 - 096600108 Screening Link Varist0r Without Led, 3Rt2-S00, 24-70 Vdc 580691 , 313000339 Opto Coupler 1No, 24 Vdc, 3A, Cage Clamp 527148 , 313000340 Patch Cable Ethernet Cat 6, 1 Meter 597005 , 094500167 Wire Protection 5Sy4 Typ C, 4A With0ut Helpswitch 433804 , 313000344 Power Supply Sitop Ac 120-230-500V-24 Vdc-5A 507285 , 094100032 System P0wer Supply Ps 25W, 24 Vdc, S7 1500 714676 , 313000341 Micro Memory Card S7-1500, 12Mbyte 595494 , 313000342 Front Plug 40-Pin S7 1500, Cage Clamp 599640 , 313000343 Fl Switch Sf 4Tx-1Fx Sc Ethernet 10-100 Rj45 24 Vdc Autocr 597854 , 094500164 Emv Flat Belt Earth Connection, Mb, 16Mm2, 200Mm, 10 Pcs. 597117 , 094500165 Putzmeister 550Cm, Ral 9005 695787 , 094500166 Skintop M32 Seal Insert For 1X Ethernet 6,5Mm 597606 , 472200016 Thermoelectric Cooler, 80W, 24 Vdc 750918 , 092800398 Led Module Blue, Sirius Act 22Mm, 24 Vdc, Frontmount, Cage 641359 , 092800399 Led Module Red, Sirius Act 22Mm, 24 Vdc, Frontmount, Cage 641356 , 313000335 Pressure Compensator M12x1,5 Stainless Steel 636016 , 091700355 Inspection Window Stainless Steel 600X522x38mm 559454 , 313000336 Operator Panel Tp6156 731587 , 313000337 Patch Cable Ethernet Cat 6, 3 Meter 597006 , 313000338 Fl Switch Sf 8Tx-1Fx Sc Ethernet 10-100 Rj45 24 Vdc Autocr 749636 , 091700356 Coupling Relay 859 1W, 24 Vdc, Cage Clamp 507804 Total Quantity : 153
Contract Date: Ref. Documents Contract Value : 37.97 Lakh
Boards / Undertakings / PSU No of Bidders 1
Madhya Pradesh View Result →
Contract Date: Jun 04, 2026 Contract Value : 24.56 Lakh
Government Departments No of Bidders 3
Madhya Pradesh View Result →
17.
Defence #11206901 AOC
Tender For Provision Of Work Services For Sdr Facility In Abr Lab At 9Brd Afs Pune Under Ge Af Lohegaon - Taking down the existing surface batten type point wiring of aluminium/Copper for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. 2 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 3 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board )ISI Marked (IS:14772) for housing switches / sockets all a specified and directed 4 (a) One Fan point/ light point controlled by one switch. 5 (b) One 3 pin socket 5 A on same board. 6 (c) One 3 pin socket 5 A on independent board. 7 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board)ISI marked (IS 14782) for housingone 15 A Switch / socketsall a specified and directed 8 M/L for sub main wiring with two runs of single core 4.0 Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor1100 V grade with colour code and one run of 4 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cablefor continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified.(Note:- Two runs of 4 Sqmm copper cable & one run of 4 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length) 9 M/L for sub main wiring with two runs of single core 6.0Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in& including casing & caping all as directed and specified . ( Note:- Two runs of 6 Sqmm copper cable & one run of 6 sqmm copper cable including PVC casing & caping shall be measured & paid as one length ) 10 Supply and fix switch piano flush type 5 Amp one way, ISI Marked 11 Supply and fix Socket out let 2in 1, 5 pin 5 Amp ISI Marked 12 Supply and fix switch socket combination 5 / 16 A, 5 in 1, flush type,ISI Marked 13 S/F Fan Regulator electronic step type 100 W,ISI Marked complete as directed 14 Supply and fix ceiling rose surface type bakelite / PVCthree terminal 65 x 50mm. ISI Marked 15 Taking down existing VTPN DB grouted in wall and S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 16 Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge. 17 Supply and fix MCB SPN B Curve 240 V, 32 Amps. complete all as directed at site. 18 Supply and fix MCB SP B Curve 240 V ,6 to 32 Amps complete all as directed at site. 19 M/L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plateNo. 3 of SSR Part I of 1991 & testing complete including 15mm dialight grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GIwatering pipe etc. 20 Supply and fixing in replacement of double pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complete all as specified and directed 21 S&F of CEE Panel mounted receptacles 16 A, 3 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 22 S&F of CEE Panel mounted receptacles 16 A, 5 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 23 S&F of CEE plug 16 A, 3 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 24 S&F of CEE plug 16 A, 5 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 25 S&F of Sub main wiringwith 4 X 6 sqmm single core cable FRLSH PVCinsulated unsheathed of copper multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 6 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 6 Sqmm & 1 length of 6 sqmm cable and PVC casing caping will be measured as one length). 26 S&F of Sub main wiringwith 4 X 10 sqmm single core cable PVCinsulated unsheathed of copper FRLSH multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 10 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 10 Sqmm & 1 length of 10 sqmm cable and PVC casing caping will be measured as one length). 27 Taking down carefuly copper strip of Size upto 32x6mm including pocelain/epoxy insulator, storing in safe custody for reuse and refixing the taken down copper strip as directed at site including supply and Fix of new epoxy insulator at a gap of 1 meter and brazing of copper strip with double nut and bolt with overlap of 3 cm complete all as directed by Engr-In-Charge. 28 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 6000K colour temperature with current electronic connections as directed. 29 Supply and fix MCB TPN 415 V, 32 Amps 10 KA C Curve in DB complete all as directed at site. 30 Supply and fix MCB TPN 415 V, 40 to 100 Amps 10 KA C Curve in DB complete all as directed at site. 31 M&L for making hole in Brick masonary / Stone masonary wall of any thickness and height of round shape and suitable for exhaust fan of 380mm dia and making good disturbed wall and painting distubed area as original complete all as directed. 32 Supply and fix exhaust fan, steel body heavy duty AC single Phase. 230V of size 380 mm sweep with, blades, and frame and louver complete all as specified and directed. 33 1. Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2TR having dual rotor inverter compressor, 100% copper IDU and ODU, installation kit with extra copper piping, connection electric cord, drain water pipe as per site requirement and incl MS Stand for outdoor unit fixng and core cutting in stone masonary wall if required for passing of refrigerant piping and cables etc and making good disturbed surfaces matching to existingcomplete all as specified and directed by Engr-In-Charge 34 Supply and fixing of voltage stabilizer for automatic operationsingle phase naturally air cooled indoor typefor input variationbetween 170V to 280V with outputVoltage 230v with accuracy +/-2.5% and of capacity 5 KVA completeall as directed. 35 Supply and laying HDPE DWC pipe 135 mm inner dia SN8 incl coupler on wall/ along ground/ along channel/ in trench/under roof/ along pillar or as directed complete. 36 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 300 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 37 S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 38 Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded copper conductor of size 35 Sqmm 3.5 Core laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix on wall etc all as specified and directed. 39 Supply install, test and commissioning of Powder coated LTpanel cubical Indoor type floor standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB/ACB and TPN Copper bus bars , incomerand outgoing feeders .The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. Thecubicle shallhave bottom frame & dimension as required for panel & stand shall be made out of equal angle iron of size 50mm x 50mm x 6mm height 600mm. A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 63 Amps & above. The panel shall be powder coated with 7 tank process of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including provision of heat shrink sleeve on each cable core within panel, lugs, nut bolts, washers etc complete all as specified and 40 a) Copper bus bar 500 Amps for 4 pole-01 SETb) MCCB FP 320 Amps415 Volt 50 KA,Ics =100% Icu WITH thermal and magnetic setting type - 1 Nosc) MCCB FP 100 Amps - 415 Volt 16 KA,Ics =100% Icu- 5 Nos f) RYB Indicators - 1 Set and g)Digital 3 Phase Amp Meter and Voltmeter with selector switch - 1 SetNote - (i) The lay out drawing of the panel shall be got approved by the contractor before panel fabrication. 41 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 25 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 42 Supply and fix Voltage stablizer for automatic operation, three phase , naturally oil cooled, inddoor type anddesigned for input variation between 300V to 480 V with accuracy + 2.5 % , IP55 Protection, 50 Hz, Unbalance type, copper wounded, matallic body duly powder coated, liftinghooks, digital display, relay controlled for smooth and silent operation with first filling of transformer oil upto specified level , with zero distortion waveform, sesitivity +/- 1%, overall Efficiency more than 95 % digital multifunction meterand speed of correction 8 volts per second and of capacity 30 KVA complete all as specified and directedNote: (a) Stablizer shall be free from hunting during automatic operation and No load losses shall not be more than 5% of rated output current.(b) Protection: (i) Overload short circuit protection at input end by MCCB 4 pole of suitable size as per recommendation of OEM - 01 Nos (ii) High / low voltage cutoff(iii) By pass arrangement - providing 01 No 4 pole on load changeover switch of suitable rating (iv) single phase sequence change protection.(c) Acceptance Test :- Testing of servo voltage stabilizer should be carried out as per BIS 9815 (Part-I) in OEM factory in the presence of rep of Accepting Officer and contractor/his rep. Contractor shall give 45 days in advance intimation with respect of date of testing. The following testing shall be carried out:(i) Physical Examination (ii) Insulation resistance (iii) High voltage test (iv) Leakage current test (v) Output voltage (vi) No load current (vii) Measurement of No load loss induced voltage testNote : Before make and specification approval type test report of OEM as per BIS 9815 Part - I should be produced by contractor for the specified capacity / next higher capacity of any voltage range from Govt Lab / NABL accredited lab. 43 Supply, installation,Boring, erection, testing and commissioningof Copper bonded(150 micron) MS solid rod electrode of dia 17.2 mm and 6 mtr long with high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm-m. Earthing Electrode shall bemade by embedding copper bonded MS Rod electrode in 100mm dia macronite conductive concrete made by mixing high purity conductive granularmixed with cement in the ratio2:1 (2 part of high purity electriclly conductive granular and 1 part cement and one litre of water per kg of mix ). The earthing electrode shall be augured inbore hole of dia not less than 100mm and6 Mtr depth. The conductive material shall confirm to BIS: 3043-2018. The rod shall be embedded in conductive concrete at factory with concrete having resistivity 0.040 Ohm-m. The top edge of the electrode shall comprise of plate provided with 04 holes for connections of the earthing strip,including brass nut bolts for connections of the strip the copper strip shall be duly brazed/welded with connection terminal of earthing rod, including FRP square chamber cover 300mm x 300mm x 250mm with top cover complete all as specified.All the material such as copperbonded MS rod and concrete mix shall be Ph nuetral, chemicaly inert and non corrosive complete all as specified and directed by Engr-In-Charge.i) The contractor shall submit type test report issued by the CPRI for high purity, electrically conductive earthings , confirms to rated short time withstand current20 KA per sec. ii) The factory made electrode shall be tested at factory and test report shall be submitted.iii) Factory testing of individual earthing shall be carried out in presence of rep of accepting officer and report shall be submitted.iv) The contractor shall obtain make approval for high purity electrically conductive granular duly by submitting certificates conforming to resistivity is 0.001 ohms by granular manufacturer.v) On installation of earthings at site, 04 to 05 Nos earthings shall be connected in grid to achieve less then 1 ohm resistance of grid, If desired resistance is not achived the contractor shall redo the same without any extra cost. vi) The contractor shall submit certificate issued by OEM of earthing electrode starting that The desired maintenance free earthing resistance less than 1 ohm. The year will be maintained for not less than 25 years. 44 M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.Note:-(i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 45 M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mmby means of bolts, nuts, checknuts & washers of copper and connecting to test point, providing charcoal and common salt ,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs,including copper earth strip 20 x 3 mmwith GI protection pipe of 25 mm medium grade 7.5 meter long, etc complete all as specified.Note-- (i) Vendors are bound to get earthing result upto1 Ohm with grid of three earthings and 2 Ohm with grid of two earthing, 3ohm with single earthing, Any additional work and material required to achive the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 46 S&F in repair of test point made out of gun metal or phosphorous bronze of size 75x50x5mm duly mounted on epoxy insulator 02 Nos.Drilling of upper & lower portion of test point for incoming & outgoing connections with brass nut bolt to be fitted in and including terminal block cover box made out of M.S sheet 2mm thick as per the sample duly painted with two coat of enamel paint over a coat of red oxide primer. 47 S & F copper earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc.and connecting with earthing test point oras required complete all as directed. Note: Earth work required shall be deemed to be included in quoted rate, nothing extra shall be paid on this account. 48 Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / pole etc. 49 Soft/loose soil 50 Hard/dense soil 51 Soft/disintegrated rock 52 Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil. 53 Removing the surplus soil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level. 54 M&L for Cutting the existing road precisely for laying of cable crossing pipe and making good the distubed surface of road as per original after laying of pipe and removal of debries complete all as directed.Note: The cost of making good is deemed to beincluded in quoted rate. 55 Supply and fixof MCCB FP 63 AmpsFixed type with breaking capacity16 KA with Sheet metal enclosure of 2 mm thick CRCA sheet single door with provision opening for incomming and outgoing cable/ submain including connections and testing for proper functioningincl taking out unserviceablecomplete all as specified and directed.
Contract Date: Feb 04, 2026 Contract Value : 35.23 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
18.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
19.
Defence #11198549 AOC
Tender For Spl Repair To Certain Md Accn In Kandhar Line Under Ge Central Delhi Cantt-10; 1 Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubbing down with water etc including remove alldebris at 2 KM away from site complete all as specified and directed. 2 M&L for 15 mm thick rendering in cement mortaron fair faces of brick work or concrete surfaces, applied in two layers i.e. 1st layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd (top) layer of 5 mm thick rendering in cement mortar (1:4 )mixed with WPCfinished even and fair etc complete all as specified and directed.(Note:- WPC shall be measured and paid separately) 3 M&L for rendering 10 mm thickin CM 1:6 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed. 4 M&L for rendering 5 mm thick in CM 1:3 on ceiling concrete surfaces finished even and fair without using extra cement complete all as specified and directed. 5 M&L for preparation of new plaster surfaces of wall and applying water proof wall putty 1-2 mm thickness over plastered surfaces to prepare the surfaces even and smooth and finishing walls with Two coats @ 1.67 ltr/10 Sqm each acrylic smooth exterior paint of required shadeover and including priming coat of exterior primer @ 2.20 Kg/10Sqm complete all as specified and directed. 6 M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper complete all as specified and directed. 7 M&L for Preparation of new surfaces (Plastered or un-plastered) of ceiling and applying two coats of oil bound distemper complete all as specified and directed. 8 M&L for complete removal of existing treatment of old decorated plastered or unplastered surfaces of wall by rubbing , brooming down, washing with water etc and applying two coats of oil bond distemper complete all a specified and directed. 9 M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing tretament, by rubbing brooming down, washing with water etc and providing and applying 1-2 mm thickness wall putty over plastered surfaces to prepare the surface even and smooth and finishing wall surfaces by applying Two coats @ 1.67 ltr/10 Sqm each with acrylic smooth exterior paint of required shade over and including priming coat of exterior primer @ 2.20 Kg /10Sqm complete all as specified and directed. 10 M&L for dismantling water tanks of capacity exc 250 litres & n. exc 500 litres complete all as specified and directed. 11 M&L for rotational moulded polyethylene water storage tanks (ISI Marked) white colour 500 litres capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT float valve, lid tank cover for polyethylene and polyethylene ball complete all as specified and directed. 12 S&F 15 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed 13 S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed 14 Demolition Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (each layer) complete all as specified and directed. 15 Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thickness removed or only a part thereof) complete all as specified and directed. 16 Removing soil excavated material exc. 1.5Km but n exc 5km and depositing where directed at above the starting pointcomplete all as specified and directed. 17 M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone crushed aggregates) on roof padding, surface finished even and smooth without using extra cement complete all as specified and directed. 18 M&L for providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer or equivalent (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalentcomplete all as specified and as per manufacturers instructions. 19 M&L for providing and applying Smartcare Dampproof or equivalent, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per manufacturers instructions and all as specified & directed. 20 Supply only integral water proofing compound (ISI marked) complete all as specified and directed 21 Demolition of brick work built in cement orcement lime mortar of any description including quoins,arches,pillars,etc., complete all as specified and directed 22 M & L for brick work with Cement Mortar 1:6 using sub class B bricks, old size, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed. 23 All As per item no 22 before but except bricks etc complete all as specified & directed 24 Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 complete all as specified and directed. 25 Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed 26 Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed 27 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified & directed. (M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 28 S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified & directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 29 S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 65 x 125 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (max toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr incharge. Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made. 30 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 31 S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately).Note: MTC and Screw Out Test shall be provided by Contractor 32 Supply and fixing 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of density 650 kg/cbm manufactured by an ISO-9001-2015 certified company. Door to be panelled with SS mosquito and XTN aluminium mesh for additional strength and safety purpose (confirming as per IS 4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. SS butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through other hardwares should be fixed with 19x6mm size steel screws, etc. complete all as specified& directed.”Note: MTC and Screw Out Test shall be provided by Contractor 33 S&F Aluminium windowfor outer frame 40mmx114mm with 1.3mm thickness ,corner 45 degree cut & aluminum welded center mullion size 40mmx65mm also welded, shutter(02) size 40mmx60mm 1.3 thickness 45degree cut mechanically joint with 6mm alen key bolt clamp , 12mm SS 202 grade round bar at 100mm cc distance in middle 150mm cc distance for safety grill welded at both ends with 6mm ss 202 grade round bar, 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock , aluminum kobra hinges 2 nos per shutter , 40x18mm 45 degree cut & welded mosquito net shutter(02) with 0.45mm nominal dia of SS wire mesh,SS 75mm long hinges & pvc magnet,full system powder coating with pure polyster coat of any shade as approved by GE and installing with SS screw roll plug and filled with silcone complete all as specified and directed. 34 S&F Aluminium windowOuter frame 40mmx114mm with 1.3mm thickness ,corner 45 degree cut & aluminum welded center mullion size 40mmx65mm also welded, shutter (02) size 40mmx60mm 1.3 thickness 45degree cut mechanically joint with 6mm alen key bolt clamp , 12mm SS 202 grade round bar at 100mm cc distance in middle 150mm cc distance for safety grill welded at both ends with 6mm SS 202 grade round bar, 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock , aluminum kobra hinges 2 nos per shutter , 40x18mm 45 degree cut & welded mosquito net shutter(02) with 0.45mm nominal dia of SS wire mesh,SS 75mm long hinges & pvc magnet,full system powder coating with pure polyster coat of any shade as approved by GE and installing with SS screw roll plug and filled with silcone complete all as specified and directed. NOTE:- For installation of windows AC/desert cooler the provn of window glass shutter with wire mesh,grill and necessary fittings and locking arrangement for subject portion will be modified as per ground requirementt during execution as direction of Engg-in-Charge. 35 S&F ventilator outer frame 40mmx40mm with 1.3mm thickness, corner 45 degre cut & aluminum welded center mullion size 40mmx65mm also welded , fixed 5mm frosted glass EPDM rubber gasket with provision for fresh air fan, full system powder coating with pure polister coat of any shade install with SS screw rol plug pvc & silicone complete all as specified & directed 36 Dismantling of wall and ceiling/cupboard board fibre pulp AC boards etc any thickness including cover fillets removing the wiring complete all as specified & directed 37 S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbmhaving good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws complete all as specified & directed. Material test certificate and authentication should be compulsory provided by the contractor. (For WC/Bathroom/Toilet/Kitchen and Cabinets) 38 S&F stainless steel continuous (Piano) hinges, bright finish, width of flap when open 30mm, complete all as specified & directed. 39 S&F of stainless steel handles 100 mm sizefor kitchen cabinet shutters and bed room cub boards complete all as per specified and directed. 40 S&F brass chromium plated tubular hanger rod 20 mm dia with suitable brackets complete all as specified and directed. 41 S&F for PVC magnetic door catches of kitchen cabinet and similar work fixed with MS screws complete all as specified & directed 42 S&F SS butt hinges medium weight 100mm size fixed with SS screws (ISI Marked) complete all as specified & directed 43 S&F SS barrel tower bolt extruded section 150mm long and fixed with SS Screws (ISI Marked) complete all as specified & directed 44 S&F 150mm extruded SS handle fabricated type and fixed with SS Screws(ISI Marked) complete all as specified & directed 45 S&F 300mm extruded section SS sliding door bolt with hasp and staple and fixing bolt and nut (ISI Marked) complete all as specified & directed 46 S&F for 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar complete all as specified & directed. 47 M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed 48 M&L for preparation of Old or previously treated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified & directed. 49 S&F for stainless steel plate rack of size 90x80x25 cm depth size made out of 1mm thick sheet complerte all as specified and directed. 50 S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet for kitchen with plug, washers, waste pipe, waste coupling incl fixing cast iron cantilever bracket connecting union over all size 915x460mm with bowl size410x330x160mm complete all as specified and directed. 51 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm etc complete all as specified & directed 52 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm etc complete all as specified & directed 53 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 40mm etc complete all as specified & directed 54 Supplying and laying 16 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete all as specified and directed 55 All as per item No. 54here in beforebut 20 mm dia complete all as specified and directed. 56 All as per item No. 54 here in beforebut 40 mm dia complete all as specified and directed. 57 S & F Floor door stopper 150mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed 58 Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for concealed water tubing etc cutting exceeding 10cm girth but not exc. 20 cm complete all as specified & directed. 59 Supply and fix in repairvitreous China wash hand basin (including pedestal)white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper and waste pipe & waste coupling including all necessary fitting and fixtures complete all as specified & directed 60 Supply and fix in repairs vitreous china squatting pan Orissa pattern long pan size 580x440mm white with integral foot rests ‘standard Grade P’ or ‘S’ trap front or back inlet (excluding flushing cistern and flush pipe) complete all as specified and directed, 61 S&F in repair vitreous china wash down water closet EWC white/ ivory/off white (closedpattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flushpipe) complete in all respect complete all as specified & directed 62 Supply only PVC low level white flushing cistern valveless symphonic action type 5/10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified & directed 63 S&F in repairs 15 mm dia 600mm long PVC connectionswith brass check nut complete all as specified & directed 64 S&F in repairs Glass Corner Shelf 6mm thick including CP railing radius 250mm complete all as specified and directed by Engineer-in-Charge. 65 S&F in repairs Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with cp railingcomplete all as specified and directed by Engineer-in-Charge. 66 S&F in repairsHealth faucet, CP brass with 1.50m long flexible pipe complete all as specified and directed by Engineer-in-Charge. 67 S&F fancy type brass chromium plated toilet paper holder, complete all as specified & directed 68 S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule Make-Jaquar/marc/Kohlar, complete all as specified & directed 69 S&Fin repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as specified & directed 70 S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as specified & directed 71 S&Ffor 15 mm bore gate valve, gun metal, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed 72 S&Ffor 20 mm bore gate valve, gun metal, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed 73 S & F in repairs Chromium plated brass overhead shower with arm complete all as specified and directed. 74 S&F in repairs looking mirror of size 600mmx450mmx5.5mm thick with aluminium frame selected quality mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 75 S&F in repairs Brass chromium plated mode 2 in 1 WHB mixture model Quarter half turn (SOLO) omplete all as specified & directed. 76 S&F in repairs brass chromium plated mode 3 in 1 wall mixture model Quarter half turn (SOLO) complete all as specified & directed 77 S&F in repairs Brass chromium plated mode 2 in 1 sink mixturemodel Quarterhalf turn (SOLO) ofas complete all as specified & directed. 78 S&F in repairs chromium plated soap dish fancy type complete all as specified & directed 79 S & F in repairtowel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embedded in cement mortar 1:3 with MS screws etc complete all as specified and directed. 80 Dismantling of floor of size not exceeding 4.00 Sqm each for EWC and removing out the cinder/concrete from sunken protion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditons, grinding any sharp edges etc all as specified and directed. (a) Cleaning or RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite.(c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified.(d) M&L for providing 25mm dia GI pipe spout projecting at least 150mm beyond outer face of wall.(e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(f) The area of Each WC portion is n.exc 4.00Sqm each.(g) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.Note : The work will be executed by authorised manufacturers/applicator. 81 Dismantling of floor of size not exc 1.50 Sqm for IWC and removing out the cinder/concrete from sunken protion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditons, grinding any sharp edges etc all as specified and directed. (a) Cleaning or RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite.(c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified.(d) M&L for providing 25mm dia GI pipe spout projecting at least 150mm beyond outer face of wall.(e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(f) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.Note : The work will be executed by authorised manufacturers/applicator. 82 Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed. 83 M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqmbut not exceeding 0.11 sqmas in floors over and including 15mm thick screed bedin cement mortar 1:4 set and jointedin neat cement slurry and pointed in coloured cement. complete all as specified and directed 84 S&F for glazed Ceramic tiles 9 to 10 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.. 85 All as per item no. 84 here in before but on vertical surfaces as in skirting etc over and including 10mm thick screed bed in CM 1:3, set and jointed in white cement with pigment to match all as specified and directed. 86 M&L glazed ceramic coloured tiles in vertical surface600x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 10mm thick in CM (1:3) complete allas specified & directed. 87 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc incl brushing neat cement slurry with 3.0kg of cement per sqmtr complete all as specified and directed. 88 M&L for Granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms with necessary hole for gas pipe where ever required and likes over and including cement mortar bedding of 20 mm thick in CM 1:4 including pointing in white cement using marble dust with admixture of pigment to match including rounded edges with shade of granite complete all as specified and directed. 89 M&L for machine cut kota stone slab flooring, and (one Pieces) as in tread, riser, landing, 20-25 mm thick over and including cement screed bed 20mm thick in CM 1:4laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. 90 M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 53 grade and two part ofsand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete all as specified and directed Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer).(c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. 91 M&L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water.All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint complete all as specified and directed. 92 Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially providedincluding removal of rubbish out side complex (MOD land), complete all as specified and directed 93 M&L for 75 mm thick cement concrete 1:3:6type C2(using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished even and smooth without using extra cement, complete all as specified and directed 94 M&L for 40 mm thick cement concrete 1:2:4type B0(using 12.5mm graded stone aggregate) as in floor & surfaces finished even and fairusing extra cement, complete all as specified and directed 95 Demolition of reinforced cement concrete in any position complete all as specified and directed 96 M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm stone crushed graded aggregate) as in louvers and jallies 25mm thick designed as fort pattern (measured solid) including all moulding but exceeding frame and set in CM1:4 all as per sample shown complete all as specified and directed 97 M&L for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone crushed aggregate) as in roof slabs, slab supported on walls, cooking platform, beams and columns, in floors roofs, landings, balconies, canopies and in chajjas, parapet, shelves and the like complete all as specified and directed. 98 Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed. 99 S&F TMTmild steel bars of 10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed. 100 Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortar of any diameter including bends complete all as specified and directed . 101 S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears ,110mm bore complete all as specified and directed . 102 S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears 75 mm bore complete all as specified and directed 103 S&F for PVC (SWR) bends & tee any radius, 110 mm bore complete all as specified and directed. 104 S&F for PVC (SWR) bends & tee any radius, 75 mm bore complete all as specified and directed. 105 S&F for PVC (SWR) door plates , Yjunction 110 mm bore complete all as specified and directed. 106 S&F for PVC (SWR) door plates ,T junction 110 mm bore complete all as specified and directed. 107 S&F for 100 PVC (SWR) bends with door plate& teecomplete all as specified anddirected. 108 S&F for 75 mm PVC (SWR) bends with door plate & tee complete all as specified anddirected. 109 S&F for 75 mm bore PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in solvent cement concrete complete all as specified anddirected. 110 S&F in repair 20 mm nominal dia and minimum thickness 1.2mm of SS-304 Grade of Stainless Steel tubefor curtain rod including pair of suitable S.S brackets approved by GE including taking down old pelmet boxes with curtain rods complete all as specified and directed. 111 Dismantling wrought iron or mild steel work of any description not otherwise provided for parapet railing, balconies, tank staging, metre rooms shaft areaany descriptioncompleteas specified and directed. 112 Supply and fix welded steel wire fabric(MS Jali) fixed to steel members weight n. exc. 4 kg/sqm including welding complete all as specified and directed. 113 S&F rolled sections as in main and cross beams, hip and jack rafters; purlins , pillars, trusses , water tank stage , framed guard bars, barred iron doors, ladders, frame balusters, walk ways, railing and similar work where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed 114 Dismentling asbestos cement corrugated orsemi corrugated sheets in roof fixed with L hook or cranked bolt complete all as specified and directed 115 S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge 116 S&F in repairs two legged aluminium floor door stopper with rubber shoe 140mm long complerte all as specified and directed by Engineer-in-Charge. 117 ROAD, PATH AND CULVERT 118 Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially providedincluding removal of rubbish out side complex (MOD land), complete all as specified and directed 119 M&Lfor 75 mm thick PCCtype D-2 1:4:8 (40mm graded aggreate) as sub-base complete all as specified and directed 120 S&F Endura colour paving tiles 30cm X 30cm x 15-20mm double charged digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. 121 M&L for Providing PCC in coping type B-1, 1:2:4 using 12.5mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified and directed 122 M&L for broken stone boulders of hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed 123 SEWAGE DISPOSAL 124 Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loosesoil complete all as specified and directed 125 Returningfilling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed 126 Removing excavated materials to a distance exc 1.50 Km but not exc 5 Km outside defence land and depositing where directed complete all as specified and directed 127 M&L for PCC 1 : 4 : 8 type D2 using 40mm graded stone crushed aggregates as in foundation of manholes, posts etc completeall as specified and directed. 128 M&L for PCC 1 : 2 : 4 type B1 using 20mm graded stone crushed aggregates as in surfaces channels and drains complete all as specified and directed. 129 Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stoped ends etc complete all as specified and directed. 130 S&F DWCPE(SN8) 150mm dia (Internal Dia)pipes, snap fit coupler and rubber ring including testing and laid and properly jointed laid in trenches to a level on concrete bed complete all as specified and directed. 131 Demolition of brick work built in cement orcement lime mortar of any description including quoins,arches,pillars,etc., complete all as specified & directed 132 M&L for Brick work with sub class ‘B’ bricks straight or curved on plan, built in cement mortar 1:4 using old size bricks complete all as specified and directed. 133 All as per item no 130 here-in-above but except bricks 134 M&L for PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Itemwater troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed. 135 M&L for precast factory made manhole cover, area of each cover n.exc 0.60 Sqm, 100mm thick with SFRCconcretingincluding grove and hook arrangement for lifting and placing in position and sides covered by MS sheet complete all as specified and directed. 136 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100mm internal dia pipe, complete all as specified. 137 M&L for rendering 15mm thick on top of roof concrete in cement mortar 1:4 with water proofing compound @ 3% by weight of cement to have a smooth surface for laying of water proofing membrane. Note: Water proofing compound will be measured and paid seprately. 138 Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),150 mm diapipe of any description and in any position set and jointed in cement mortar complete all as specified and directed by Engr-in-Charge 139 INTERNAL ELECTRIFICATION 140 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc 141 Taking down old MCCB , TPN DBs , SPN DBs (incl MCB SPN & SP) & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed. 142 Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. 143 Disconnecting elect connection and taking down of ceiling fan/ Exhaust fanof any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge. 144 M&L for point wiring complete with 1.5 Sqm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit of 20 mm nominal diaand conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and including provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel concealed in walls, with modular sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, complete all as specified and directed for the following:- 145 One light /Ceiling fan/exhaust fan point controlled by one switch. 146 One light point controlled by two, two way switch ( switch to be measured and paid separtely) 147 One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. 148 One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board 149 One bell point controlled by one bell push. 150 All as per item Ser No 142 here-in-before but point wiring with 2.5 sqmm single core FRLS 1100 Volts in New PVC concealed conduitmedium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 2.5 sqmm single core FRLS 1100 Volts copper conductor cableas earth continuityconnected to common earthfor one 15 A switch socket power point, complete all as specified and directed 151 M&L for submain wiring 4 Sqmm nominal cross sectional area,two single core, 1100 Volts grade, multi-stranded, PVC insulated unsheathed, FRLSHcopper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of suitable dia, medium grade with all conduit accessories and connected to common earth dolly to suitable copper lugs including all cutting/chases etc in walls and making good to the disturbed surfaces to match the existingsurfaces.Note:- Three run of single core wire andone run of conduit shall be measured and paid as one unit complete all as specified and directed 152 All as per item ser No 144 here-in-before but for 02 x 6 Sqmm for phase & neutral and 01 x 6 Sqmm for continuousearth wire concealed/surface 153 M&L for switch Modular type 6 Amp one wayISI marked complete all as specified and directed. Make : Legrand Cat Part No 573400 / Schnider Cat No X1001WH / Wipro Cat No RF 110 154 M&L for switch Modular type 6 Amptwo wayISI marked complete all as specified and directed. Make : Legrand Cat Part No 2573402/ Schnider Cat No X1002WH/Wipro Cat No RF 210 155 M&L for switch Modular type type 16 Ampone way,ISI marked complete all as specified and directedMake : Legrand Cat Part No 573410/ Schnider Cat No X11001WH/Wipro Cat No RF 130 156 M&L for Modular type socket outlet 2 in 1, 5 pin 6 Amp ,ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573424/ /Schnider Cat No X2005WHNS/Wipro Cat No R 1212 157 M&L for Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573471/ Schnider Cat No X2106WH/ Wipro Cat No R 1332P 158 M&L for ceiling rose 3 phase PVCpolycorbonate,isolated body, complete all as specified and directed 159 M&L for bell push,modular type, 6 Amp, 1 moduleISI marked complete all as specified and directed.Make : Legrand Cat Part No 573413/ Schnider Cat No X1005WH/ equivalent in Wipro 160 M&L for bell ding dong AC, 230 volts, single pole complete all as specified and directed. 161 M&L for angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified anddirected. 162 S&F LED bulb 12 watts, 1200 lumens output, 6500K suitable for B-22 base complete all as specified and directed. 163 M&L for earthing complete with GIelectrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earthplate not less than 1.50 mtr below normal ground level connected to GI wire 4.0 mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze drilled and screwed all as specified including excavation and earth work and disposal of surplus soil incl 15 mm GI tubing light grade and necessary fitting for protection of GI wire incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MSangle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised wire and protection light grade GI pipe upto 7.5 mtr, excavation, etc shall be deemed to be in the quoted rates. 164 S&F sheet metal enclosure distribution board confirmingto IEC - 61439-3, single pole and neutral, AC 240 volts, 08 way witn 100 Amps rated copper bus bar and metal double door with IP-43 & IK 09protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete ( Note - MCB & DB shall be of same make) 165 S&F sheet metal enclosure distribution board confirmingto IEC - 61439-3, single pole and neutral, AC 240 volts, 12 way witn 100 Amps rated copper bus bar and metal double door with IP-43 & IK 09protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete ( Note - MCB & DB shall be of same make) 166 S&FMCB confirming to ISI/IEC -60898-1 (2002), SPN, AC, 240 volts, of 40Amps capacityB curve, 10 kA breaking capacity & making connection by using using suitable copper lugs complete all as specified and directed. 167 S&FMCB confirming to ISI/IEC -60898-1 (2002), SP, AC, 240 volts, of 6-32Amps capacityB curve, 10 kA breaking capacity & making connection by using using suitable copper lugs complete all as specified and directed. 168 Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 120 Lumens/watt andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. 169 S&F in replacement of LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.90, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 140 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥120 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. 170 M&L for in replacement Decorative wall mounting CITY-1 Decorative wall light fixture made up of Polycarbonate,Power Factor > 0.90 voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 110 Including 12 W retrofit LED BULB (B-22 base). NOTE- one piece of LED bulb 12 watts included with city -1 fitting complete all as specified and directed. 171 Supply and fix in replacement 10 watts bulkhead fitting, IK 09 with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover,including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. 172 Taking down existing electric meter & refixing the same after completion of job with electric connection by 8 way DB in good way by cleaning and qtr No. marking complete all as specified and directed.. 173 Supply and fixingexhaust fansmetal body AC single phase 230/240 V of size300 mm sweep, Air flow rate > 900cum/min, Bird screen forprotectionagainst birds, double ball bearing, metal body with louvre also with louvre for fixing of exhaust fan complete all as specified and directed. 174 Supply and fixing new BLDC fan against old ceiling fans BLDC conversionthree blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5star rating for energy saving, rated Air delivery >220 cum/min,AC single phase 230/240 V of size 1200 mm sweep including fan regulators,down rod, canopy & all accessories including making connection with three core flexible, copper winding in fan,copper cable pvc insulated of suitable length, complete all as specified and directed. NoteBLDC Fan should work onelectronic fan regulator & also with remote controled. 175 S&F modular type sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall complete all as specified and directed. 176 S&F of water heater storage type Geyser vertical type with suitable size of fastner and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity including provision and connecting up of SS braidedpipe with adopter for inlet and outlet wwater connection having edjustable knob for temperature control and inner tank should be glass line coated, capacity25 Ltrs, having heating element 1.5 KW and not less than 5 star rating,suitable for ,230 volt,50 Hz electric supply complete all as specified and directed . 177 S&F fresh air fan PVC body air delivery > 800 CMH , 5 number of blades, AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed. 178 S&F in replacement pressure die cast aluminium housing LED street light luminaires with IP-66 deg. of protection suitable for 35 watt LED fitting, Power Factor > 0.90 voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 110 duly fixed on 25 mm dia GI pipe light grade including 40 X 6 mm thick MS flat with suitable size of fastner including making connection flexible copper conductor cable from ceiling rose to fitting complete all as specified and directed. Note : Quoted rates shall be inclusive of all accessories like suitable GI pipe, 40x6 mm thick MS flat, fastner, nut & bolts, suitable length of flexiable wire etc. 179 S&F in repair factory made epoxy powder coated Distribution Board VTPN-4 ways (IP-43 protection), mechanical impactstrength IK - 09, with cement spill protector double doorfabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one MCCB 125/160 Amp as incomer and12 Nos of SP MCB 10 to 63 Amps outgoing and conforming to HSN code : 8537 complete all as specified and directed. Note :- MCCB & MCB will be measured & paid separately. 180 S&F in replacement MCCB 125 Amps, thermal magnetic release,4 pole 16 kA ICS=ICU Complete all as specified and directed.
Contract Date: May 30, 2026 Contract Value : 3.02 Crore
Statutory Bodies & Commissions/Committees No of Bidders 11
20.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
22.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
23.
Educational and Research Institute #11161433 Price Bid
Procurement Of Equipment, Instruments, Machinery, Tools Etc. Related To Laboratories And Workshops Of Electronics And Telecommunication Engg., Engineering Physics, Engineering Mechanics Of Mirik Government Polytechnic, Mirik, Dist. Darjeeling, 734214 , Spherometer (Screw Pitch 0.05 Mm And Lc 0.005 Mm) , Concave Mirror (Focal Length 20 Cm) , Convex Mirror (Focal Length 20 Cm) , Concave Surface (Focal Length 20 Cm Diameter 50 Mm) , Hooks Law Apparatus (Consisting Of 30 Cm Long Mirror Scale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand) , Mercury (Distilled Liquid Mercury, Grade Std.-Biotech Grade) , Flywheel Apparatus (Thickness: 4.4 Cm Diameter :20 Cm) , Cantilever (Length 100 Cm, Hook At One End, C Clamp) , Light Weight Hanger (Metal Slotted Weight Mechanics Physics Experiment Equipment Set With Hook With Weight Of Each Mass Of The Order Of 50Gm Or 100 Gm) , Inverse Square Law Apparatus (Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter) , Stopwatch (Digital Stopwatch With Ms Count) , High Resistance Box (Resistance Box Plug With 1 To 10 K Ohm Resistance) , Winch Crab Single Purchase With Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut.String, Weight Box With Pan. ] , Winch Crab Double Purchase Without Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut. ] , Worm And Worm Wheel Single Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Worm And Worm Wheel Double Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Wheel & Axle Simple Without Weight [Standard Setup For Lab.] , Simple Screw Jack With Weight [Experiment Set Up Screw Jack ( Weights)All Metallic Construction Accurately Machine Cut Screw With A Pitch Of 5 Mm Carrying A Double Fanged Turn Table Of About 20 Cm Diameter. Fitted On A Heavy Cast Iron Base And Complete With Two Adjustable Pulleys, Cord And Hook. Weights Are Included.] , Combined Inclined Plane & Friction Slide Apparatus Iron Base & With Weight [Standard Setup For Lab.] , Parallel Forces Apparatus [Experiment Set Up Simple Supported Best Type Supported At Its End. For Verification Of Condition Of Equilibrium Of Parallel Forces, Law Of Lever & Forces On Beam Etc. Consisting Of Two Compression Thrust Type 10 Kg Tubular Spring Balances Fixed On Wooden Polished Board, A Wooden Beam With Steel Back Plate. Complete With Two Strups, Hooks & Two 10Kg Weights. ] , To Verify Lami’S Theorem [Gravesand Apparatusboard: Wooden With Metal Base Pulley: Z-Pullies (2 Nos) With Adjustable Distance Weight Set: 5X50 G (3 Sets). ] , Simple Jib Crane Apparatus Iron Stand With Weight [Experiment Set Upwith Consisting Of A Tubular Compression Balance, Pivoted About An Axis Fitted To The Base. The Tie Chain Has An Adjustable Angle Bracket And Fitted With A 10Kg Extension Balance. Completion Wooden Base With 1.2 Meter Jib. With Weights. ] , Mini Drafter, T Square, Protractor, Set Squares, Compass, Divider [Made Out Of Wood. To Be Used In Chalk Board] , Model Of Geometric Constriction (Solid Cube, Solid Primed, Cylinder, Cone, Hexagon, Tetrahedron ) [Made Out Of Wood. To Be Used In Chalk Board] , Amplitude Modulation And Demodulation Trainer Kit [Message Signal:100 Hz To 2.8 Khz, Carrier Signal 28 Khz To 108 Khz,Modulation : Balanced Modulator, Amplifier : Op Amp Based, Demodulation : Diode Detector & Lpf(6Th Order)] , Frequency Modulation Anddemodulation Kit [On-Board Message Signal With Variable Amp/Freq,On Board Carrier Signal Fm Modulation Using Xr 2206Ic,Demodulation Using Pll Detector And Lpf 4Th Order Lpf,Internal Power Supply +5V , +12V/ 500 Ma] , Super Heterodyne Am Radio Receiver Trainer Kit To Measure Sensitivity, Selectivity And Fidelity [On Board Variable Capacitor Tuning,Receiving Antenna,Local Oscillator,Bfo, Rf Amplifier, Mixer,If Amplifiers, Detectors, Agc,Audio O/P Amplifier, Speaker.Frequency Range: 400Khz To 1700Khz,If Frequency: 455 Khz.] , Pam, Pwm And Ppm Modulation And Demodulation Trainer Kit [Provides Sine Waveform Output Of 250Hz, 500Hz, 1 Khz, And 2 Khz With Amplitude Adjustments Of 0 - 5Vp-P. Switch Selectable Sampling Clock Of 4, 8, 16, 32 Khz. On-Board Features Analog Sample Circuit/Output, Sample & Hold Circuit/Output, Flat Top Circuit/Output, 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz.] , Analog Signal Sampling & Reconstruction Trainer Kit [±15V D.C. At 100Ma, Ic Regulated Power Supply, A.F. Signal Generator For Modulating Signal.Sampling Clock Generator To Provide Sampling Clock And Gate Pulse. Modulator Circuit For Flat-Top Natural And S/H Circuit. Demodulator Circuit To Reconstruct Input (Sinewave)] , Telephone Receiver Trainer Kit [Line In Section : One Dot Line Connection Port.Handset : One Handset Connection Port. Keyboard : 4X3 Matrix Keyboard.Dialer : Tone And Pulse. Facilities : Redial Up To 32 Digits, Mute, Redial, Flash, Pause Switches.Indicators : Line In, Hook, Tone And Ringer, Call Mute Section.Control : Ringer Volume Control, Ringer Speed Control.Speech Path : Fully Non-Blocking.Dial Pulse Ratio : 10 Pps + / - 10%.] , 100Mhz Digital Oscilloscope [Bandwidth: 100 Mhz, 2 Analog Channels+ Ext With Probes Included Rise Time: =3.5 Ns, Real-Time Sample Rate Of 1 Gsa/S 1% Dc Gain Accuracy Should Support Rs232/Uart, I2c And Spi Bus Triggers And Decodes Usb And Ethernet Connectivity] , 30Mhz Analog Cro [Dual Trace Dual Channel Oscilloscope. Bandwidth: 20Mhz. Full Bandwidth Sweeping Circuit , Tv-H / Tv-V Synchronization And Trigger-Lock To Observe All Kinds Of Signals Stably. Y Deflection Operation: Y1, Y2, Alt, Chop, Add, Mode.Horizontal Sweep Mode: Auto, Trig, Lock, Single.X-Y Mode Input: X-Axis Yi And Y-Axis Y2.] , 2 Mhz Function Generator [Frequency: 1Hz – 2 Mhz Sine, Square, Triangle, Ttl Output] , Digital Storage Oscilloscope (100 Mhz) [Bandwidth 100 Mhz, Channels: 2+, Display: Tft Color Lcd Of Suitable Size (Capacitive Touchscreen). Sampling Rate: 1 Gsa/S Real Time, Sampling Mode: Normal, Average (2, 4, 8, 16, 32, 64, 128, 256), Peak Detect. Mathematics: A+B, A-B, A×B, Fft (Fast Fourier Transform). Fft Windows: Rectangle, Hanning, Hamming, Blackman. Auto Measurement: Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay1-2 (Rise), Delay1-2(Fall) ] , Trainer Kit For Rectifier With And Without Capacitor Filter For : — (A) Half-Wave Rectifier, (B) Full-Wave Rectifier, (C) Bridge Rectifier [Transformer Rating : 9-0-9V/200Ma, Rectifiers : Half Wave; Full Wave - Bridge, Center Tapped Rectifier,On-Board Dc Voltmeter : 0 - 20V,On-Board Ac Voltmeter : 0 - 20V,Load : Variable Resistive Load 10K,Filter Circuit : In-Built- Capacitor (3Nos.),In-Built- Inductor (1No.),Input Line Voltage : 230V Ac ± 10%, 50Hz] , Push-Pull Amplifier Trainer Kit [I.C Regulated Power Supply : +6 V.Digital Ac Voltmeter: 0 – 20 V.Digital Ac Milliammeter : 0 – 200 Ma.Set Of Resistances.Set Of Capacitors.Two Transistors Cl 100 And Ck 100.Connecting Wire.] , Fet Characteristics Trainer Kit [Variable Dc Regulated Power Supply Of 0-5V At 250Ma. Dual Range Dc Voltmeter Of 1.5V/15V.Dc Ammeter Of 0-20Ma.] , To Determine Frequency Response Characteristics Of Rc Coupled Amplifier Circuit And Calculation Of Bandwidth, Midband Gain, Input Impedance And Output Impedance For: (A) Single-Stage Amplifier (B) Double-Stage Amplifier [Sine Wave Oscillator 15Hz To 150Khz In Four Ranges With Amplifier & Amplitude Adjustable.Three Decade Resistances Bank In Steps Of 1K, 10K & 100K Per Steps Total Step 30.Two Pnp Transistors.] , Mosfet Characteristics Trainer Kit [On Board Ammeter And Voltmeter,Dual Variable Dc Power Supplies,On Board Mosfet And Fet With Resistors To Perform Experiments] , To Study The Input And Output Characteristics And To Find The H-Parameters Of A Bjt For : — (A) C-E Configuration, (B) C-C Configuration, (C) C-B Configuration [Power Supply 1) 0-1V Dc 2) 0-10V Dc.Meters Dc 65Mm Four Dial V, V , Ma Ua/ Ma.Transistor Cl100/ Similar] , Component Development System [Power Supplies On Boards 0-15 V And 0-30 V, 250 Ma Each Variable.Fixed Dc Regulated Power Supplies 15 V/250 Ma And 5 V/250 Ma.Ac Power Supply 15-0-15 V For Rectifier Applications.Various Components On The Trainer Set. ] , Kcl & Kvl Trainer Kit [Two Dc Ic Regulated Power Supplies 0-12 V/150 Ma, Two Mr65 Square/Digital Meters For Voltage & Current Measurement, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Power Cords 230 V, 50 Hz] , Thevenin’S And Norton’S Theorems Trainer Kit [Power Supply 2?3?0?V, Regulated & Short Circuit Proof Variable Dc Voltage Source – 01 No. Fixed Resistance Of Different Values. Dc Voltmeter.Dc Ammeter. Glass Fuse For Short Circuit Protection. On/Off Switch With Indication Light. Patch Cords Suitable To The Terminals With Board For Easy Interconnection.All Above Accessories Will Be Fitted On Bakelite Sheet Fixed On Box.] , Superposition Theorem Trainer Kit [Instrument Comprises Of Two Fixed Output Dc Regulated Power Suppliesof 12V & 5V At 500 Ma Current, Three Moving Coilmeter, Circuit Diagram Printed On The Front Panel & Connections Ofsupplies, Meter & Resistances Brought Out At 4Mm Sockets. ] , Maximum Power Transfer Theorem Trainer Kit [Ammeter 30Ma Dc. Voltmeter 12V Dc. Power Supplies: Dc Supply Ic Regulated 0-12V Dc, 150Ma. Operated On Mains Power 230V, 50Hz +10% Components Are Mounted On The Panels Are: Resistances 2Watts Variable Resistor Voltage Control Through Potentiometer. Fuse For Short Circuit Protection. Patch Cords 4Mm.] , Reciprocity Theorem Trainer Kit [Instrument Comprises Of One Fixed Output Dc Power Supply Of 12V At 300 Ma Current, Two Moving Coil Meters, Circuit Diagram Printed On The Fornt Panel & Connections Of Supplies, Meters & Resistances Brought On Terminals.] , Series And Parallel Resonant Circuit Trainer Kit [Analog Meters: Ammeter 20Ma Ac. Voltmeter 20V Ac. Components Mounted On The Panels Are: 3 Nos. Of Resistors Selected By Rotary Switch. 3 Nos. Of Capacitors Selected By Rotary Switch. 3 Nos. Of Inductors Selected By Rotary Switch.] , Low Pass And High Pass Filter( Rc & Lc) Constant K Type Trainer Kit [Instrument Comprises Low Pass Circuit Rc Type Instrument Comprises Low Pass Circuit Lc Type Instrument Comprises High Pass Circuit Rc Type Instrument Comprises High Pass Circuit Lc Type Instrument Fitted In Highly Shockproof Plastics Box] , T And ? Type Attenuator Trainer Kit [Instrument Comprises Ofdc Ic Regulated Power Supplies 0-15V/150Ma. Two Mr65 Square / Digital / Round Meters For Voltage & Current Measurement. T And Pie Network Provided On The Board. Variable Resistor Using Band Switch Is Mounted On The Board. Instrument Fitted In Highly Shockproof Plastics Box. Sufficient No Of 4Mm Patch Cords For Interconnection Instruction Manual For Student Workbook. Power Cords 230V, 50Hz] , To Study Standing Wave Pattern For A Transmission Line Of Finite Length With: (A) Open Termination, (B) Short Termination, And © Matched Termination. [Transmission Line : Coaxial Cable 100M ( 25M X 4 Nos) Impedance Matching Resistance : 0 To 100 ( 02 Nos ) Test Generator : 1. Sine Wave : 4 Khz To 4 Mhz. 2. Square Wave : 10 Khz. Interconnections : 4 Mm Sockets On All Input / Output Connections. Test Points : 10 On Board Circuit Mimic : Illustrates Functional Blocks For Ease Of Experimentation Power Requirement : 230V 10% 50Hz, 1 Ac. Accessories Provided : I. Set Of Patch Cords. Ii. Bnc To Bnc Cable. Iii. Bnc To Crocodile. Iv. Detailed Instruction Manual.] , Digital Trainer Kit (Experiment 1. -To Verify The Truth Table Of Not, Or, And, Nand, Nor, Xor, X-Nor With Ttl Logic Gates And Cmos Logic Gates. Experiment 2.- To Realize Different Boolean Expressions With Logic Gates. Experiment 3.-To Realize Half-Adder, Full-Adder, Subtractor, Parallel And Serial Full-Adder. Experiment 4-To Design 1’S Complement, 2’S Complement And 9’S Complement Adder-Subtractor.) [Dc +5V , 400Ma; Dc +12V, 250Ma; Dc -12 V, 250Ma, Dc0 To + 30V: Variable 100Ma,Ac Output: 12V-Ct-12V, 150Ma; Logic Data 8-Bit Debounced Set/Clear Ttl Output With Bicolour Led; Clock Generator I Hz To 200Khz Variable & Manual, Ttl & /Ttl(Complement) With Bicolour Led;Logic Probes 8-Bit 3-State Led Display High, Low, High Impedance; Function Generator Sine, Square, Triangle, 1 Hz To 250 Khz;Bread Boards : 3 X 820 Tie-Points; Total Short Circuit Protection From Any To Any Point On Board] , Complete Setup To Implement The Truth Table Of Encoder,Decoder, Multiplexer And De-Multiplexer. [The Trainer Kit Should Be Able To Verify The Truth Tables Of Truth Table Ofencoder,Decoder, Multiplexer And De-Multiplexer.] , Complete Setup To Design/Construct Parity Generator, Checker And Comparator. [Industry Standard Specification To Perform Relevant Experiments. ] , Flip Flop Trainer Kit [Kit For Verification Of Jk, Sr, D, And T Flip-Flop Truth Tables] , Complete Setup To Design / Construct Binary Synchronous And Asynchronous Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design / Construct Programmable Up/Down Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design Controlled Shift Register And Study Their Function. [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Study Different Memory Ics [Industry Standard Specification To Perform Relevant Experiments. ] , A/D & D/A Converter Trainer [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Interface Ttl And Cmos Ics. [Industry Standard Specification To Perform Relevant Experiments. ] , 8051 Trainer Kit [Operating Frequency : 10Mhz Crystal,40-Pin Ic Base | 40Pin-Zif Socket,2×16 Char Lcd Display,32 I/O Pins,32Kb-Sram,32Kb-Eeprom.] , Ct-31/51 Or 8031/51 Microcontroller Trainer Kit With Led Display, Usb Interface & Inbuilt Power Supply [Operating At 10/12 Mhz, On Board 8K Ram,8/16K Bytes Of Eeprom,48 I/O Lines,Hexadecimal Keyboard And Six Seven Segment Displays,Rs-232C Interface,Usb Interface] , Ct-31/51Lcdadu8031/51 Microcontroller Trainer With Lcd Display, Usb Interface, Adc, Dac& Inbuilt Power Supply [Trainer Based On 8051/89C52 Microcontroller.On Board 32K Ram.64 K Bytes Of Eeprom.20 X 2 Lcd Display.48 I/O Lines. Onboard Adc & Dac.] , Adc Interface Module [Usb Interface, Adc Module Module 10 Channel 12Bit Ad Sampling Data Acquisition Stm32 Uart Communication Adc Module] , Dac Interface Module [Operating Voltage 2.7-5.5 V. Interface Type I2c. Resolution 12 Bits.] , Lcd Display Module [Display Contents :16 * 2 Characters (5*8 Dots ). Lcd Size :80 X 36 Mm .Lcd Thickness :9.5 Mm.] , Keyboard Interface Module [5X4 Keys Matrix Keyboard. ] , Dc Motor Controller Module [Driver Module : L298n. Motor Supply Voltage (Max.): 46V.Motor Supply Current (Max.): 2A. ] , Stepper Motor Controller Interface Module [Robocraze Stepper Motor(28Ybj-48 Dc 5V 4 Phase 5 Wire) + Uln2003 Driver Board Compatible With Arduino] , Trafic Light Controller Module [Led Traffic Lights Signal Module/Digital Signal Output Traffic Light Module] , Temperature Measurement Module [Electrobot Dht11 Digital Temperature & Humidity Sensor Module For Arduino And Rpi] , Operational Amplifier Trainer Kit ( Ic 741 ) [Inbuilt Variable/Fixed Dc Regulated Power Supplies.Output Voltages : 0-5Vdc (2Nos.) (Variable), +12Vdc (Fixed).Transistor & Components Provided Ic : 741.Transistor : Cl 100 (Npn).] , Active Filter Trainer Kit (Lpf, Hpf, Bpf) [Opamp Based First Order Lpf, Hpf, Bof Trainer Kit (Mi-A14)] , Application Of Ic555 Timer Trainer Kit (Astable & Monostable Mv) [In-Built Regulated Dc Power Supply.On Board Manual Pulse Generator For Triggering The Monostable And Bistable Circuit.Inbuilt Led Output Indicator.Symbols And Diagram Are Printed On Glass Epoxy Pcb.] , Opamp Based Oscillator Trainer Kit ((A) Hartley, (B) Colpitt, (C) Phase Shift, (D) Wein Bridge) [Op-Amp Oscillator Trainer Mi-A13. Frequency 50-60 Mhz.] , Crystal Oscillator Trainer Kit (741 Based) [Industry Standard Specification To Perform Relevant Experiments. ] , Function Generation Kit (Using Icl8038) [Icl8038 Function Signal Generator Sine Triangle Wave Kit Diy Professional K5e8.Uses Icl8038 And High-Speed Op Amp, Higher Accuracy. Low Distortion Sine Wave: 1%.] , Voltage Regulator Trainer Kit (Using Ic723) [0-35V D.C. At 250Ma, Countinously Variable Unregulated Power Supply.D.C. Milliammeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 50Ma And 250Ma.D.C. Voltmeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 10V And 40V.Ic 723 Fitted On Base.Three Potentiometers.] , Function Generator Trainer Kit [Frequency Ranges: 1? Hz To 1?0? Hz, 1?0? Hz To 1?0?0? Hz Fuse:3?5?0? Ma, Slow Blow Automation Grade: Manual Power Supply:Max 2?3?0?V Ac, 5?0? Hz +/- 1?0?%] , Maxwells Bridge Trainer Kit [The Kit Contains A Bridge With Provision For Connections Of Capacitors And An Unknown Inductor. In Built Ac Supply [ 1 Khz And 2 Vpp ] And Dc Supply [ +5 V ] On Board. Two Nos Dial Resistances [ 50 Ohm To 200 Ohm ] And [ 1 Ohm To 11 Ohm ] In Step. A Dc And Ac Null Detector Using Selector Switch. A Dial Type Variable Capacitor [ Range 0.2 Uf Ro 1.2 Uf ] And Six Nos. Unknown Inductors [ Range 1 Mh To 12 Mh ].] , Lvdt Trainer Kit [Excitation Source Built In Ac Source 2.5 Khz Sine Approx. L.V.D.T. In Non Metallic Structure. Micrometer One (For Displacement) Displacement Range 10Mm. Test Points Sockets At Different Places For Signals. Potentiometer Two For Zero & Calibration Adjust Display (Mm) 3.5 Digit Digital Power Supply Ic Regulated Phase Detection Balanced Demodulator Power Supply Short Circuit &Overload Protected Mains 230V/50Hz Ac] , Strain Gauge Trainer Kit [Strain Gauge: 4 Mounted Upon Cantilever 150X3.5X3.5Mm, Stable Dc Voltage For Strain Gauge Bridge, Opamp Based,Precision Instrumentation Amplifier With Variable Gain,Potentiometer For Zero And Calibration Adjust,3.5 Digit Display For Strain/Weight, 230V 50Hz Ac] , Temperature Transducers Kit Using (A) Rtd (Pt-100) (B) Thermistor. [12 - 0 - -12 V 500Ma To Drive Digital Integrated Circuitry. 5 - 0 - -5 V 250Ma To Drive A To D Converter Signal Conditioning And Amplifying :Analog To Digital Converter. Display : 31/2 Digit Led Display Of 200 Mv Fsd Initial Set : Single Turn Potentiometer To Set Initial Temperature ( Room Temperature) Final Set : Single Turn Potentiometer To Calibrate The Instrument ( Max. Temperature) Select : 2 Way Rotary Switch To Select Rtdand Thermistor. Power On : Rocker Switch To Control Power Supply To The Instrument.] , Calibration Of A Single-Phase Energy Meter By Phantom Loading Trainer Kit [Usage/Application: Lab Experiment Connection:4?-Mm Patch Cord Single Phase Automation Grade:Manual Power:2?0?0? W Voltage:2?2?0?-2?4?0? V] , Calibration Of A Voltmeter Using Crompton Potentiometer Trainer Kit [This Trainer Is Supplied Along With Highly Regulated Dc Power Supplies To Operate The Unit. Further To Calibrate Pmmc Meters, Necessary Ratio Boxes Also Provided. Resistors Used In This Unit For Coarse And Fine Are Very Standard Type Made Of Manganin. This Enable The User To Measure The Potential In A Circuit Close To Micro Volts. Necessary Schematic/Wiring Diagram Printed On The Panel To Follow And Conduct Experiments. User Manual And 4Mm Patch Cords Supplied. Accessories Included: Necessary Dc Power Supplies, Ratio Boxes & Galvanometer Are Provided Alongwith The Unit.] , Cro Demonstration Kit [Crt : 6Rectangular Screen With Internal Graphical 8X10 Division (1Div-1Cm) Vertical Deflection Display : Ch1, Ch2, Add, Alt & Chop Deflection Factor : 5Mv/Div To 5V/Div +3%, 1Mv/Div To 1V/Div, +5% (X5), 10 Steps Rise Time : <17.2Ns Maximum Input Voltage : 250 (Dc + Ac Peak Value) When <1Khz (250V, Dc +Ac) Input Coupling : Ac, Dc & Gnd Polarity Selection : + (Ch2 Only) Display Mode : 1, 10 & X-Y Horizontal Deflection Time Base : 0.2Us/Div To 0.2S/Div, 9 Ranges Sweep Expansion : X10 Accuracy : +3% Triggering Mode : Auto, Norm, Tv-V, Tv-H Triggering Source : Int, Line & Ext. Trigger System Auto : 20Hz-20Mhz Norm : 0.5 Div Int, 0.5 Vp-P Ext Tv-H : At Least 1 Div Or 1 Vp-P Input Impedance : 1Mohm X-Y Phase Difference : <3 Degree, Dc-50 Khz Calibration Waveform : Frequency 1Khz 2%,Voltage 0.5 V 1%, Block Diagram Printed On The Top Panel, Power Requirement: 220 Vac +10% , 50 Hz] , Q-Meter Kit Formeasurement Ofq Of Coils. [Inductance Range:199.9Mµh-19.99H Resistance Range (Ohm):19.99O-19.99M? Capacitance Range:199.9P-1.999?F Capacitance Accuracy: ±(1%±2) Digital Lcr Bridge Meter Power:220 Volts/50Hz ±10%] , Spectrum Analyzer Trainer Kit [Industry Standard Specification To Perform Relevant Experiments. ] , Public Address System Trainer Kit [To Test The Performance Of Loudspeaker And Microphone; Power Output: 100W Rms At 10% Thd Pre-Amplifier Output: 200Mv; Line Output: 1V/ 1K?; Input Channels: Mic: 2Nos; Frequency Response : 65 Hz To 15 Khz +/- 3Db Tone Controls : Bass, Treble, Master 1Control; Speaker Outputs : 4 , 8 , 16 , 70-100V Line Matching; Speakers : 2 Nos; Microphones : 2 Nos(Dynamic Microphone)] , Demonstration Kit Of Black & White Tv Trainer [To Learn The Practical Aspects And Faults Which Would Occur Often In The Black And White Tv. All The Fault Switches Are Provided To Conduct Fault And Observe The Output. The Test Points Are Provided To Determine The Voltages At The Different Sections Of The Tv And Observe The Signal Output Of The Various Sections. The Output Is Monitored On A 20” Picture Tube.] , Demonstration Kit Of Colour Pattern Generator For Colour Tv [They Should Be Able To Make Various Patterns, Including Vertical Bar Patterns, Horizontal Bar Patterns, Circle Patterns, 100% White Patterns, Check Patterns, Horizontal Bar Patterns, Vertical Bar Patterns, Color Bar Patterns, Red Color Patterns, Green Color Patterns, Blue Color Patterns,Yellow Color Patterns, Magenta Color Patterns, And Cyan Color Patterns. Learning Materials To Be Included: Theory, Procedure, Reference Results, Etc.] , Demonstration Kit Of Colour Led Tv Trainer [Display Type: Led; Hd Screen Size: 24 Inch (50Cm) Or More; Display Resolution: 1600 X 900 Pixels Or More; Video Interface: Video Input/ Vga, Hdmi And Or Dvi Input; Audio Output Power: 8W X 2; Receiving System: Pal Bg/I/Dk And Ntsc; Channel Coverage: Vhf-2-12, Uhf21-69; Catv (X~Z+2, S11s41) Mains Supply: 110-260V Ac ± 10%, 50/60Hz; Power Consumption: 35W] , Demonstration Kit Of Dth Trainer Kit [Colour Tft Lcd: 5.7” Tft Lcd; Rf Input: 950 - 2150 Mhz; Rf Output: 470 Mhz Two 862Mhz; Video Output: Pal/Ntsc; Uplink Satellite: Insat 4B; Test Points: 34 Nos.; Included Accessories: Mains Cord, Power Supply, Remote, Dish Antenna With Accessories, Lnb] , Demonstration Kit Of Photocopier [Interface Hi-Speed Usb 2.0 Copy Speed Simplex To Simplex Up To 20 Ppm In A4 (21 Ppm In Letter) Scan Method Color Cis Compatibility Twain, Wia Fault-Creating Facilities For Crum, Thermistor, Stepper Motor, Pickup Clutch, Feed Sensor, Width Sensor, Scanner Stepper Motor, Scanner Sensor, And Printer Door. Various Fault Switch With Test Points Provided On-Board.] , Demonstration Kit Of Fully Automatic Washing Machine Trainer Kit [Semi/Fully Automatic Washing Machine Mechanical Controls 30 Minutes Timer, Wash/Spin Control Atleast 6 Liter Capacity Machine Fault Switches For Wash Motor, Spin Motor, Lid Opening, Buzzer Etc All Faults Are Mounted On Pcb With Enclosure] , Demonstration Kit Of Microwave Oven Trainer Kit [Type: Solo; Capacity: >15 Ltr; Power Consumption: 600 Watt Or More: Child Lock And Alarm, Various Test Points] , Demonstration Kit Of Refrigerator [Industry Standard Specification To Perform Relevant Experiments. ] , Demonstration Kit Of Air Conditioner. [Industry Standard Specification To Perform Relevant Experiments. ] , Tdmpulse Code Modulation Trainer Kit [Crystal Frequency: 12/16 Mhz On Board Generators, 1. Adjustable Amplitude Sine Generator Of 500Hz & I Khz (Synchronised) 2. Variable Amplitude Dc Level (2 Nos.) Input Channels: Two Multiplexing: Time Division Multiplexing Modulation: Pulse Code Modulation Sync Signals: Pseudo Random Sync. Code Modulation Error Check Code: Off, Odd, Even, Hamming Operating Modes: Fast 240 Khz Channel (Approx) And Slow I Khz Channel (Approx) Pc - Pc Communication: 2 Channel Via Rs 232 Baud Rate: Selectable From 300 To 2400 Fault Switches : 8 Nos. Through 8 Way Dip Switch For Troubleshooting At Different Blocks Should Include Various Test Points] , Tdm Pulse Code Demodulation Trainer Kit [2 Channel Time Division Multiplexed Pulse Code Modulation Receiver. Fast (240 Khz/Channel Approx) And Slow (1Hz. /Channel Approx.) Mode Of Operation Pseudo Random Sync. Code Generator For Frame Synchronization. Receiver Clock Generation Using Pll. Error Detection Of None, Even, Odd, Hamming. Error Correction Using The Hamming Code Technique None, Even, Odd, Hamming Parity Selections Two Nos. Of 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz. Four Switched Faults For Fault Selection Block Description Screen Printed On Glassy Epoxy Pcb] , Fdm Transmitter / Receiver Kit [Two Variable Modulating (Sinusoidal) Input Channels With Provision Of Voice Inputs Two Dsbsc Modulators For Frequency Band Translation Of Two Test Signals Two Carrier Generators Two Sets Of Audio Input Amplifier One Adder/Transmission Amplifier Two Demodulators Two Low Pass Filters For Smooth Output] , Ask / Psk / Fsk Modulation And Demodulation Kit [The Kit Should Have An Integrated Ask / Psk / Fsk Modulation And Demodulation. Various Functional Block Diagrams Are Provided On-Board For Teaching/Training. Test Points To Visualize The Signals On Oscilloscopes] , Microwave Test Bench (Klystronbased) [Complete Klystron-Based Test Bench Study Of The Characteristics Of The Klystron Tube And To Determine Its Tuning Range, To Determine The Frequency & Wavelength In A Rectangular Waveguide Working On Te 10 Mode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , Microwave Test Bench (Gunn Based) [To Study The V-I Characteristics Of Gunn Diode, To Study The Voice Communication By Using Microwave Test Bench, To Study The Following Characteristics Of Gunn Diode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , 24 Awg Tinned Single Strand Jumper Wire Spool Blue Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Green Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Red Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Black Colour [90 Meter Spool] , Flexible Electric Wire [2 Core, Twisted Flexible, Red And Black, 0.5 Sq Mm Copper Core, 50M Length] , Soldering Wire [Flux Core, Coil Type (Wire Of 100Gm )] , Inductor 1 Mh [8X10 Mm Radial Leaded Power] , Inductor 10 Mh [8X10 Mm Radial Leaded Power] , Led Red, Green, Blue, White Colour. Fifty Numbers Of Each Colour Led. [0.5W, Through Hole Type] , Ic 7400 [Ttl Ic-Quad 2-Input Nand Gate] , Ic 7402 [Ttl Ic-Quad 2-Input Nor Gate] , Ic 7404 [Ttl Ic-Hex Inverter Gate] , Ic 7408 [Ttl Ic-Quad 2-Input And Gate] , Ic 7432 [Ttl Ic-Quad 2-Input Or Gate] , Ic 7486 [Ttl Ic-Quad 2-Input Xor Gate] , Ic 7474 [Ttl Ic-Dual D Positive Edge Triggered Flip-Flop, Asynchronous Preset And Clear] , Ic 7476 [Ttl Ic-Dual J-K Flip-Flop, Asynchronous Preset And Clear] , Ic 7490 [Ttl Ic-Decade Counter (Separate Divide-By-2 And Divide-By-5 Sections)] , Ic 7495 [Ttl Ic-4-Bit Shift Register, Parallel In, Parallel Out, Serial Input] , Ic 74200 [Ttl Ic-256-Bit Ram (256X1)] , Ic 74147 [Ttl Ic Encoder] , Ic 74138 [Ttl Ic 3 To 8 Line Decoder] , Ic74151 [Ttl Ic Multiplexer] , Ic74138 [Ttl Ic Demultiplexer] , Ic 74169 [Ttl Ic Up-Down Counter] , Ic 74180 [Ttl Ic Parity Checker/Generator] , Ic 74Ls83 [Ttl Full Adder With Carry Ic] , Ic 74330 [Ttl Ic-Pla (12 Inputs, 50 Terms, 6 Outputs)] , Ic 4077 [Cmos Ic Xnor Gate] , Ic 4001 [Cmos Ic Nor Gate] , Ic 4011 [Cmos Ic Nand Gate] , Ic 4070 [Cmos Ic Exor Gate] , Ic 4071 [Cmos Ic Or Gate] , Ic 4077 [Cmos Ic Ex-Nor Gate] , Ic 4081 [Cmos Ic And Gate] , Ic 4093 [Cmos Ic Nand Gate] , Ic74ls47 [Bcd To 7-Segment Decoder/Driver Ic (7447 Ic) Dip-16 Package] , Lts542 [7-Segment Display - Common Anode] , Lts543 [7-Segment Display - Common Cathode] , Ic Dac0808 [Dac0808 8-Bit Digital To Analog D/A Converter Ic Dip-16 Package] , Ic Adc0809 [Adc0809 8-Bit A/D Converter With 8-Channel Multiplexer Ic Dip-28 Package] , Ic723 [Voltage Regulator Ic Input Voltage Up To 40V Output Voltage Adjustable From 2 To 37V Positive Or Negative Supply Operation Series, Shunt, Switching Or Floating Operation Output Current To 150Ma Without External Pass Transistor Adjustable Current Limiting] , Icl8038 [Function Generator Ic Wide Frequency Range - 0.001Hz To 300Khz Variable Duty Cycle - 2% To 98% High Level Outputs - Ttl To 28V Simultaneous Sine, Square, And Triangle Wave Outputs] , Ad633 [Analog Multiplier Ic 4-Quadrant Multiplication Low Cost, 8-Lead Soic And Pdip Packages Complete—No External Components Required Laser-Trimmed Accuracy And Stability Total Error Within 2% Of Full Scale Differential High Impedance X And Y Inputs High Impedance Unity-Gain Summing Input Laser-Trimmed 10 V Scaling Reference] , Lm566 [Vco Ic Wide Supply Voltage Range: 10V To 24V Very Linear Modulation Characteristics High Temperature Stability Excellent Supply Voltage Rejection 10 To 1 Frequency Range With Fixed Capacitor Frequency Programmable By Means Of Current, Voltage, Resistor Or Capacitor] , Ic Ne555 [Ne555 Timer Ic Dip-8 Package, Pack(Set) Of 30 Ics] , Ic 741 Op-Amp (Dip) [741 Ic - Dip Package - General Purpose Op-Amp Ic, Pack(Set) Of 50 Op-Amps] , Transistor 2N3904 [Pack (Set) Of 20 Transistors] , Transistor Bc107b [Pack (Set) Of 20 Transistors] , Diode 1N4007 [Pack (Set) Of 50 Diodes] , Fet- Bfw10 [Pack (Set) Of 50 Field Effect Transistors] , Zener Diode 5.6V, 1W [Pack (Set) Of 20 Zener Diodes] , Potentiometer 1 K?, 10 K?,100 K? Power Rating: 1W [20 Nos Of Each Value] , Wire Stripping Pliers, 6 Inch Long [Stainless Steel, Rust Resistant.] , Long Nose Mini-Pliers [Stainless Steel, Rust Resistant.] , Resistor 33O, 56O, 68O, 82O, 100O, 120O, 200O, 220O, 270O, 330O, 390O, 470O, 680O, 1K?,1.5K?. Maximium Power Rating 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Resistor 2.2K?, 2.7K?, 3K?, 4.7K?, 5.6K?, 6.8K?, 8.2K?, 10K?, 20K?, 36K?, 56K?, 68K?, 100K?, 470K?, 1M?, 2M? Maximium Power Rating: 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Disk Ceramic Capacitor Of Values 220 Pf, 0.01 ?F, 0.024?F, 0.1?F, 0.24?F [Pack(Set) 25 Nos Of Capacitors For Each Valueh] , Disk Ceramic Capacitor Of Values 10?F(63V), 100?F, 220?F, 470?F(50V) [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Polypropylene Capacitor Of Values 0.001 ?F,0.01 ?F, 0.1 ?F, 0.22 ?F [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Tantalum Capacitor 10 ?F (25 V) [Pack(Set) Of 25 Capacitors] , Incandescent Bulb, 40W, 100W, 200 W [With Tungstenfilament And B22 Connector]
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
West Bengal View Result →
25.
Defence #11150449 AOC
Tender For Provision Of Offers Mess Under Ge (N) Udhampur; 2 Construction of block of Offrs Mess complete all as shown on drawings and as specified. 3 Construction of block of Servant Quarter complete all as shown on drawings and as specified. 4 Construction of block of Car Garage (09 Cars) complete all as shown on drawings and as specified. 5 TotalAmount of Sch A Part - II (Internal Water Supply Work) 6 TotalAmount of Sch A Part - III (Internal Electric Supply Work) 7 TotalAmount of Sch A Part - IV (Plumbing Work) 8 TotalAmount of Sch A Part - V(Area Drainage Work) 9 TotalAmount of Sch A Part - VI (Sewage Disposal Work) 10 TotalAmount of Sch A Part -VII (Road, Path, Culvert and Hard Standing Work) 11 TotalAmount of Sch A Part - VIII (External Water Supply Work) 12 TotalAmount of Sch A Part - IX (External Electric Supply Work) 13 TotalAmount of Sch A Part -X (Compound Wall , Fencing and Gate Work) 14 TotalAmount of Sch A Part -XI (Hot Water Supply Work) 15 Sch A Part - XII (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 16 Construction of septic tank for 50 users (Brick construction) complete all as shown on drg No. CEUZ /TD-1585/2021 sheet 1/4 to 4/4 and as specified. 17 Construction of soakage well (Brick construction) 1.8m dia and 3.0m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4. 18 Supply, installation and comminssioning of water cooler, fully stainless steel, electric driven single phase having storage capacity 120 litres and nominal cooling capacity of 60 Litres per hour, fitted with hermetically sealed air compressor operating on refrigerant R-134a or 410a, conforming to IS-1391 Part-II) complete all as specified and directed. 19 Supply, installation and comminssioning of refrigerator, double door BEE 5 star rated frost free, digital inverter with hermetically sealed compressor of min capacity 256 litres suitable to use on 230 volt, AC supply complete all as specified and directed. 20 Supply, installation and comminssioning of metal top deep freezer BEE 5 star rated hard top having capacity 320 litres, double door, single phase 240 V, 50Hz, complete all as specified and directed. 21 Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 2 KVA, complete all as specified and directed. 22 Supply, installation, testing and comminssioning hi wall split unitsindoor/outdoor complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating inverter technology and EER 3.2, single phase, capacity 1.5 TR, complete all as directed. 23 Supply, installation, testing and comminssioning hi wall split unitsindoor/outdoor complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating inverter technology and EER 3.2, single phase, capacity 2.0 TR, complete all as specified and directed. 24 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed. 25 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed. 26 Supply, installation, testing and commissioning of solar hot water heating system (Flat plate collector) based on indirect transfer of heat for 300 liters as per IS-12922 and IS-12978 with electrical backup of 2KW, including angle iron support (60mmx60mmx6mm) with nut, bolts, washers and painting with two coat of synthetic enamel paint over one coat of red oxide primer for mounting of hot water plant and cold storage tank, complete all as specified and as directed.Note:- Cold water storage tank shall be measured and paid separately. 27 Construction of valve pit of size (90x60x60)cm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 coping with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts in coping including painting of steel surface with two coats of synthetic enamel paint over a coat of redoxide primer as finishes coat including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed. 28 Supply , installation, testing & commissioning of transformer of capacity 100KVA step down outdoor type level - III, copper wounded, 11/0.433KV (at no load) AC 3 phase, vector group Dyn 11, 50HZ on secondary side double wound oil immersed naturally air cooled with external cooling tubes /radiator , delta connected as on primary and star connected with netural brought out on secondary side and having tapping at -2.5% to +7.5% in steps of 2.5% to be changed by external hand operated self position off load tap change switch. Also provision shall be made for locking the taping switch handle in position. The maximum temperature rise shoud not exceed 35 degree centigrade on top of oil when measured on thermometer and 40 degree centigrade in HV/ LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall confirming to IS 1180-2014 transformerlossess shall be as per latest ammendment No IV as per IS 1180 part - I 2014 and comprising of following accessories complete all as specified and as directed. (Contd.../) 29 a) 03 No porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods nuts.b) 01 No cable end box on LV secondry side consisting of 05 No porcelain bushing (One No neutral earth, One No Neutral and 3 No for phaseconnected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core 400 Sqmm cable 3 runs, LT 1100 V grade XLPE insulated heavy duty including gland joint complete. c) Oil conservator with filter type drain valve and oil level guage.d) Dehydrating breather with first filling of dehydrating agent e) Explosive vent.f) THERMOMETER pocket including temperature gaugeg) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strips.(Contd.../) 30 h) OneNo thermometer dail type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge : Max reading painted terminal.i) Rating plate with terminal plate.j) Oil level guage.k) Oil drain filter valve.l) Oil filling hole on top cover with plug.m) Air release valve/plug.n) 4 Nos plain solid cast steel detachable rollers. o) First fill of tranformer oil conforming to relevent ISI and tested upto 60 KV dielectric strength.p) Two No lifting hook at side of transformerNote : Transformer must be as per Energy efficiency Level-3 of IS: 1180:2014 with amendment No. 4. 31 Construction of PCC platform for transformer of size 3m x 3m and 1m high from ground level with brick construction in walls and steps, PCC 1:5:10 type E-2 in foundation, brick workin CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushedstone aggregate). In flooring40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer complete duly surrounded with XPM fencing of length not less than 15 meter and width not less than 10 meter complete with 40mmx5mm angle iron & 12mm dia steel bars, fixed on PCC gate pillers complete including sliding bolt, locking arrangements hinges and all accessories,shown on drawing No CE/TD/1129/96 sheet No. 1/2 & 2/2complete all as specified. 32 Earthing complete with galvanized steel earth plate electrode600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 33 10W decorative inverted tripod type LEDBollard with IP-65 protection, soft 360 degree light distribution body made of die cast aluminium & in triangular shape including 10 W LED with IP 65 ingress protection, 4 KV surge protection, Luminaire should have high efficiency isolated poted driver minimum height of bollard 800mm & with 180mm OEM should have inhouse NABL approved Lab & submit LM-79 report along with NABL certificate, PCC foundation with necessary nuts & bolts complete all as directed by GE. 34 Post top lantern, LED type, 40 watt including40 watt LED AC, outdoor type with decorative post top for 360 degree indirect light IP 66 protection with impact, glare free and better uniformity and corrosion resistant, LED driver shall be constant current type potted driver, luminaire shall have surge protection devices of minimum 10KV inside the driver compartment. Total harmonic distortion shall be <10% with power factor minimum 0.95.The driver shall have an effiviency>85%. It should give consistent performance in the input voltage range of 120V-270V at 50Hz, luminaire shall be embossed or screen printed with manufacturer name/logo, OEM should have in house NABL approved lab and submit LM79 report along with NABL certificate, PCC foundation with necessary nuts and bolts complete with driver and lamp complete all as specified and as directed. 35 Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (32x6)mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 36 Sintex box of size 155mmX210mmX92mm, hinged (L) wiith 2 way connector mounted on epoxy insulators for looping of cablefor phase and neutral fixed on polewith the help of MS nuts bolts and MS clamps; 2 No of size 40mm X 4mm thick, with one No MCB SP 6 Amp capacity mounted on din rail inside box, including making suitable hole in pole to take out connections to fitting if required at site and provisioning of conector of street light, complete all as specified.Make:- Hensel, Sintex or equivalent make approved by GE. 37 LED street light fitting 70 Watt, 230 V, AC, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed. 38 Supply, installation, testing and commissioning offactory made outdoor type CPRI approved dust and vermin proof LT panel board front opening (double shutter) with locking arrangement of suitable size made out of 3.15 mm thick CRCA sheet with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring,thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1)of suitable size as per panel board 0.5mtr above ground level grouting and bottom portion of enclosure shall be minimum 30cm above ground level of legs of angle ironand supply & comprising of the following including internal pre-wiring complete:- 39 INCOMING(i) MCCB 4 pole 160 Amp 16 KAKA thermal magnetic adjustable type- 01 No. (Incoming) (ii) Voltmeter 0-500 V with selector switch(Digital type) - 01 set. (iii) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set(iv) Indicator lamp neon/ LED type RBY -01 Set of three.v) Aluminium bus bar capacity 250 Amps for Phase-R-Y-B- N - 4 No.OUTGOING:(i) MCCB 3 pole 125 Amp 16 KA thermal magnetic adjustable type -02 No. (Outgoing)(ii) MCCB 3 pole40 Amp 16 KAKA thermal magnetic adjustable type01 No. (Outgoing)(iii) MCB SPN 32 Amps 10 KA - 01 No (Outgoing)(iv) Time switch 250 V single phase of 20 Amp rating - 01 No(v) Complete wiring of the panel board with FRLSH PVC insulated multistrand copper conductor cables of suitable current carrying capacity end terminated with lugs and bolts, nuts and washers of galvanised iron.Note: The rate quoted should include the cost ofexcavation/PCC work as per manufacturers recommendation. 40 Bracket made out of GI tubing 40mm dia, light grade 1.5mtr long including fixing withMS clamps - 2 No made out of 50mm wide, 5mm thick, flat iron with M.S nuts bolts 75 mm long 12mm dia, - 4 No with flat washer (3mm thick) - 02 No including painting with two coats of aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete, including 1.5sqmm 3.0 core, flexible Copper cable from juction box to connecter of street light fitting complete all as specified and as directed. . 41 Cable route marker with route indication at every 30m length on cast iron disc of 100mm dia and 5mm thick, marked/written for HT cable 11000 VOLTS embosed including indication direction fixed/bolted to 40mm x 40mm x 6mmthick MS angle iron support of 0.50 m long embedded upto 200mmdepth in concrete block of size 200mmx200mmx500mmcasted in PCC 1:3:6 type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surface, complete all as specified and as directed. 42 Road crossingby adopting trenchless tunneling work through specilised pipe jacking method by errecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any kindof soil including hard rock,inserting DWC HDPE casing pipe in any length, and necessary conveyance charges of machinery and other required materials in co-ordination with the concered authorites all as specified and as directed. Note: Quoted rate is deemed to be inclusive of all necessary tools/plant/machinery and obtaining necessary permissions to carryout the work. 43 Point wiring complete with 1.5 sqmm PVC insulated, FRLSH, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc; metal flush boxes suitable modules as directed with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches,sockets,fan regulators, red colour indicator, blank plates etc. as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLSHunsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:- 44 One light/fan/bellpoint controlled by one switch 45 One 3/5 pin socket outlet, 5 Amp on independent board 46 One socket outlet 3 Pin, 5 Amps, on the same board 47 One two way point controlled by one 2 way switch 48 One light point controlled by 2 way switches, 49 Point wiring for power point control by one switch with 2.5 Sqmm nominal area PVC insulated single core multi standard copper conductor FRLSH insulated and undheathed heavy duty cable in colour code including earth wire with cable of size 2.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealed in PVC conduit of not less than 20mm dia and 1.5mm wall thickness (ISI marked) terminated into annealed steel terminal boxes including modular frame and cover plate for fixing of switches, sockets etc; complete all as specified and as directed. 50 Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia, medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly, complete all as specified and as directed.Note:- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 51 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmmas earth continuity conductorconnected to commen earth dolly complete all as specified and directed.Note: - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 52 Sub main wiring with four run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including two run ofsingle core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed.Note: - Four run of 6 sqmm single core copper conductor cable and two run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 53 Sheet metal, VTPN distribution board (DB) fitted with DPX3, 160 MCCB, 04 way, (DPX3 -160 +12), complete with metal door, 415 volts rating and IP 56 protection the DB shall be fixed flush to wall and including all internal connection, necessary reducer lugs all as directed by Engr-in-Charge. 54 MCB, Single pole, 240 volt, 40 Amp, 10KA rating,C curve, complete with connection testing and commissioning, complete all specified and directed. 55 Deduction to be made from BOQfor Sch A Part -XIII (Schedule of credit) during AOC.Note: Tenderers shall not quote for this schedule.
Contract Date: May 23, 2026 Contract Value : 4.61 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Jammu And Kashmir View Result →
26.
Power #11144553 Technical Bid
Tender for Supply Of Electrical Spares And Minor Stores/Hardware Items From The Original Equipment Manufacturer, Their Authorized Dealer/Local Representative Or Local Ssi Units Registered Firms/Suppliers Already In The Trade For The Year 2026-27 , Hardware Fitings And Accessories,Clamps And Connectors For Acsr /Aaac Conductor , Single Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type ) , Single Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type ) , Single Tension Hardware Fitting For Acsr Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type ) , Single Tension Hardware Fitting For Acsr Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type) , Single Tension Hardware Fitting For Acsr Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type ) , Single Tension Hardware Fitting For Acsr Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type) , Double Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc.. (Station Type) , Double Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type ) , Double Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc.. (Station Type) , Double Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type ) , Double Tension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type) , Double Tension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc ( Line Type) , Double Tension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type) , Double Tension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc ( Line Type) , Single Tension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Tension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Tension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Tension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Hardware Fitting For Aaac Panther Conductor 37/3.15Mm Conforming To Is 2486 (Part-I) Amended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Hardware =7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Single Tension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Hardware = 9000Kg Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Double Suspension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Double Tension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Compression Type Repair Sleeve Suitable For Aaac Panther Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , Compression Type Repair Sleeve Suitable For Acsr Panther Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , Compression Type Repair Sleeve Suitable For Acsr Zebra/Moose Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , 4R Stock Bridge Type Vibration Damper Suitable For Aaac :Panther (Of 37/3.15Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Aaac Panther (Of 37/2.88Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Acsr Panther (Of 37/3.15Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Acsr Panther (Of 37/2.88Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , Mid Span Compression Joint For Acsr Panther (Of 37/3.15Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Panther (Of 37/2.88Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Aaac Panther (Of 37/3.15Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Aaac Panther (Of 37/2.88Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Zebra (Of 54/7/3.18Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Moose (Of 54/7/3.18Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Armour Rods Helically Twisted Suitable For Acsr Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Acsr Zebra To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Acsr Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Aaac Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Disc Insulator 70Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 70Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 90Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 90Kn B&S Type, Without Anti Fog(Reputed Make/ Already Use In Pdd) , Disc Insulator 120Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 120Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 160Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 160Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Gi Nuts And Bolts Of Sorts (16Mmx35mm/ 40Mm/45Mm/50Mm & 65Mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (10Mmx75mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (10Mmx50mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (12Mmx50mm) Heavy Duty , Aluminium Cable Tray Of Size 400 Mm X3000 Mm , Aluminium Cable Tray Of Size 300 Mm X2500 Mm , M.S. Angle Iron Of Size (45X45x5)Mm , M.S. Angle Iron Of Size (50X50x5) Mm , Steel Tor Of Dia 8Mm , 10Mm, 12Mm For Cable Ducts , Spring Washers 16Mm Heavy Duty , G. I Wire Swg No. 8/ 4.06Mm Dia , Red Oxide Enamel Paint (Asian, Nerolac/ Berger) , Al. Paint (Asian, Nerolac/ Berger) , Smoke Grey Enamel Paint (Asian, Nerolac/ Berger) , Yellow/White Paint (Asian, Nerolac/ Berger) , Cement Permier (Asian, Nerolac/ Berger) , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 T-Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided , Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975 Bimetallic Ct- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther With Clamp Sutitable For 132/33Kv CtS Of Ae Mumbai, Sct Gaziabad, Bhel Vidhyut Control Andhra, Mehru Bhiwadi/ Laxmi Engg Bhopal, Jyoti.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132/33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S, Gr Power, Skipper, Bimco.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Breakers Of Sf 6 Type-Abb,Cgl, Siemens, Bhel/Vcb Type- S&S, Gec Alsthom, Bhel, Abb, Siemens, Megawin Etc. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Breakers Of Sf 6 Type-Abb,Cgl, Siemens, Bhel/Vcb Type- S&S, Gec Alsthom, Bhel, Abb, Siemens, Megawin Etc. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , P.I. Clamp For Acsr Zebra Conductor , P.I. Clamp For Acsr Panther Conductor , P.I. Clamp For Acsr Moose Conductor , P.I. Clamp For Acsr Moose Conductor , Twin Bushing Clamp Acsr Moose For 132/33Kv Transformer 1200Amp Without Poles , Twin Bushing Clamp Acsr Moose For 220/132Kv Transformer 1200Amp Without Poles , Isolator Jaw 1600Amp For 33Kv Isolator , Isolator Jaw 2500Amp For 33Kv Isolator , Isolator Jaw 1600Amp For 132Kv Isolator , Isolator Jaw 2500Amp For 132Kv Isolator , 245Kv, 50C/S , 1600 Amp, 40Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 245Kv, 50C/S , 1600 Amp, 40Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , 145Kv, 50C/S , 2000 Amp, 31.5Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 145Kv, 50C/S , 2000 Amp, 31.5Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , 36Kv, 50C/S , 2500 Amp, 25Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 36Kv, 50C/S , 2500 Amp, 25Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , Jumpers Cone For Acsr Panther , Jumpers Cone For Acsr Zebra , Spacers For Acsr Zebra , Spacers For Acsr Moose , Spacers For Acsr Panther , Earth Wire Tension Clamp , Electrical Items And Spares , Shunt Capacitor Fuse 40A With Spring Complete Assembly , Silcagel Crystal Size 8- 8 Mesh , Silcagel Breather Box 10Kg , Aluminium Tape , Chemical Jelly , Grease , Distilled Water , Transformer Oil Sampling Bottle , Welding Electrodes Swg 8No As Per Is: 814 Of 2004 , Welding Electrodes Swg 10No As Per Is: 814 Of 2004 , Search Light With 300-500Mtr. Focus Make Flash, Equivalent Etc , Led Flood Light Complete 90/100Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Flood Light Complete 140/150Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Flood Light Complete 1900/200Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Street Light Fitting 190/200Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Lamp 9 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Led Lamp 15 Watt (Philips, Havells, Crompton, Bajaj /Reputed Make) , Led Lamp 18 Watt (Philips, Havells, Crompton, Bajaj /Reputed Make) , Led Lamp 45 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Lamp Holder Pendant/Angular (Anchor,Havells,L&T,Philips/Reputed Make) , Led Tube 4 Pin 18 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Mcb 5-10 annual periodical maintenance Two Pole (Havells, Anchor,Standard, Hpl) , Mcb 10-16 annual periodical maintenance Two Pole (Havells,Anchor,Standard, Hpl) , Mcb 10-16 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mcb 32 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mcb 63 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mccb 100 Amp, 4 Pole, Ics= 100% Icu (Havells, Standard, L&T) , Mccb 200/400/600Amp,4Pole,Ics=100% Icu(Havelles,Standard,L&T) , Main Iron Clad Switch Tpn 415V,400A , Rubber Mat 1Mtr X2mtr= 12Mm Thick , Cable Ferrules A To Z And 0 To 9 , Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Copper Mesh (30Cmx5cm) , Copper Wire 8Swg , Copper Thimbles 8Mm , Copper Thimbles 10Mm , Alumunium Thimbles 2.5 / 6 Mm , Alumunium Thimbles 8 / 10 Mm , Fhelmet , Starter 36Watts , Tube Four Pin 36 Watts , Choke 36Watts , Rubberized Cork Sheet 6Mm , Rubberized Cork Sheet 10Mm , O-Rings For Bushings/Inspection Plates Of Transformer 5Mm-10Mm Diameter , Rubber Sealings For Marshalling Kiosks/Control & Relay Panels , Cooling Fans Of 3 Phase 50Mva , 33Kv Vaccum Interrupter Suitable For 33Kv Vcb Of Bhel,Abb,Gec Alstom,Seimens,Megawin, S&S Make , Thermal Overload Relay Seimens Make With Range 0.8-1.2 annual periodical maintenance , Thermal Overload Relay Seimens Make With Range 1.2A-2.5 annual periodical maintenance , Thermal Overload Relay Seimens Make Of 4A Max With Range 0.1-1Amp And 1.5A-1.2A , Mn2 Thermal Overload Relay With Start And Off/Reset Relay Of Range 0.9-1.5A L&T Make , Relay 500V,2A, Fuse 6Amp. Mn2 Make L&T , Relay 415V,3.2-5A,Class 10A Mn2 Makesiemens 3Ua50 00-1F , Relay 415V,Lth=10A,Le=4A Mn-A1 Make L&T , Dc Change Over Relay Dcco, Make Abbrxme-1-Rk221-052-Annrk711004 , Dc1 Supervision Make Abb Tsr-In352 , Anti Pumping Relay Make Schrack/Abb Or Equi , Auxillary Relay, Voltage Selection Relay 75A, Rxpsu14n-Imyn563646-Dau, Aux Voltage:110V Dc, Case Size:2S 12C, Contacts:13No+1Nc, Reset Type:Electrical, Flag:Yes, Make Abb , Auxillary Relay, Tc-1 Supervision Relay195, 7Pj1321-5Aa210aa0, Aux Voltage:24-23V Dc, Contacts:2C/O, Reset Type:Self Make Siemens , Numerical Relay, Dir. O/C & E/F Protection Relay67/67N 7Sj6611-5Eb90-1Fgo-Lor, Aux Supply:110/250V Dc, Case Size:1/3 19,16 Bi, 7 Bo,1 Life Contact,4*I, 4*U,Ct:1A, Vt:110V/220V,50Hz, Iec61850, 100 Mbit Ethernet, Electrical, Double, Rj45-Connector Make Siemens , Thermostat Make Apt/Veilco/Eq , Auxiliary Air Break Contactor Of Ac2/Ac3 Duty Cycle Number Of Poles 03, Voltage 415V, annual periodical maintenance 0-2 A, Contacts 2No+2Nc,Make Siemens , Magnetic Control Contactor Make Andrew Yule Power 44W Volt 110V Dc Ith 10A Is 13947 Iec 947 , Contactor 415V, 12Amp Lth 10Amp,Le 4Amp Mnx12 Make L&T , Contactor 415V, 12Amp Lth 10Amp,Le 4Amp Mna1 Make L&T , Contactor 415V, 20Amp 3Tf31 01-0A Make Siemens , Contactor 415V, 9Amp Lth 10Amp,Le 4Amp Mnx9 Make L&T , Auxillary Contactor 3Th3022-0B-F4, Aux Supply:110V Dc, Contacts:20O-2Nc 89Ax Make Siemens , Cooling Fans 3 Phase Motor,415V,560Watt,900Rpm,0.9Amp/1Amp(Size 600Mm) , Cooling Fans 3 Phase Motor,415V,700Watt,550Rpm,1.5Amp(Size 600Mm) , Digital Oti 90-250V Ac/Dc, Range 0-150Degree Make Precimeasure Control Banglore , Digital Wti Meter Make Precimeasure Control Banglore , Megawatt Meter , Digital Megawatt Meter, Bezel Size: 96*96Mm, 4-1/2 Digits, Aux Supply:110V Dc, Accuracy:0.5, Ctr:1200:800-400/1A Ptr:33Kv/110V Make Ae , Mvar Meter Digital Mvar Meter, Bezel Size:96*96Mm, 4-1/2 Digits, Aux Supply: 110V Dc, Accuracy:0.5, Ctr:1200-800-400/1A Ptr:33Kv/110V Make Ae , Ammeter Digital Ammeter, Bezel Size:96*96Mm, Aux Supply:110V Dc, Accuracy: 0.5, Range:1200-800-400/1A, Inbuilt Selector Switch Make Ae , Selector Control Switch Er Make 1224 Swiso , Digital Ac Ammeter,Makeae Digital 4, Range 0-600A, Ct Ratio 600/1A, Size 130X130 Mm. , Electronic Hooter, Aux. Supply 110V Dc, Freq. 48-63 Hz, O/P95-105 Db Size 96X96x82 Mm. , Lubricator Make Sae80w/90 Type Oil , Glass Sleeves , Crc Bottle , Teflon Tape , Single Core 63Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Single Core 63Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Fan Contactor Seimens Ice 158.1 Auxiliary Contactor 2No+2Nc & 4No+ 4Nc , Seimens 3Ta6702 2 To 10A, Auxilairy Contactor 3No+2Nc,Cs3-P Iec947 En60947 V=6Kv Ac-1 690V-1A Ac-15 , Solder Flux , Single Core 300Sq Mm 33 Kv Voltage Grade,Al Conductor, Pvc Insulated, Sheathed, Armoured, Xlpe Cable Likely Make Havelles Etc , Pvc Unarmoured Copper Control Cable 2.5Mm Sq 2 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 2 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 4 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 6 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 8 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 10 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 12 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 16 Core , Pvc Copper Wire 1 Mmsq , Pvc Copper Wire 1.5 Sqmm , Pvc Copper Wire 2 Sqmm , Pvc Copper Wire 4 Sqmm , Pvc Copper Wire 6 Sqmm , Copper Glands 19/25/32Mm , Switch 5A , Switch 15A , Socket 5 Pin, 5A , Socket15 Pin, 5A , Fan Regulator 10A , Dp Switch 32A , Pvc Tape Roll , Indicating Pygmy Lamp 220V/110V Dc, Pin Type / Screw Type , Semaphore Indicator For Isolator S89a Ntc12, Aux Supply:110V Dc, With 3Kohm, 6W External Resistor Make Dav , Push-Button & Indicating Lamp For Ann. Accept 3Sb50 00-0Ab01+ 3Sb54 00-0A, Normal Actuator With Plastic Front Ring And Black Holder Contact (1N0+1Nc) , Auxillary Switch 8No+ 8Nc Make Shirka/Shubhada/Eq , Local Remote Switch Make Shirka/Switron/Kaycee , Rotary Switch, Local Remote Switch 8 Ways, Handle:Pistol Grip, Position:Local/Remote, Stay Put, (Local-4Ways, Remote-4 Ways), 25A; Lockable Type, Bezel Size:75 Sq.Mm , Limit Switch 3Se3 023-0A, Contacts:1No+2Nc Make Siemens , Control Switch Bcs 3 Position ,Pistol Grip 16 Ways Make Switron , Control Switch Bcs 3 Position ,Pistol Grip 20 Ways Make Switron , 3 Core 95 Sq Mm 11Kv Xlpe Cable , Sf-6 Gas Cylinder Of 9Kg , Sf-6 Gas Cylinder Of 11Kg , Nitrogen Cylinder Of 16Kg Containing 9Kg Gas , O2 Cylinder Refilling , Anti Rodent Device , Control Switch For Panels Reputed Make , Hrc Fuse 2Amps , Hrc Fuse 4Amps , Hrc Fuse 6Amps , Hrc Fuse 10Amps , Hrc Fuse 10Amps , Hrc Fuse 32Amps , Hrc Fuse 32Amps , Hrc Fuse 100Amps , Fuse 3Nw20nnsf+3Nwns10, Aux Voltage:110V Dc, Rating:10A Make Siemens , Fuse 3Nw20nnsf+3Nwns4, Aux Voltage:110V Dc, Rating:10A Make Siemens , 33Kv Phase Limb Of 33Kv Circuit Breaker (Abb Make) , Breather Box For 133.33 Mva/160 Mva/150Mva, 220/132 Kv Transformer (Bhel/Abb Make) , Breather Box For 50 Mva,132/33 Kv Power Transformer (Bhel/Cgl/Ece/Emco Make) , Numerical O/C And E/F Relay Make:Easun Reyrolle , Model: Mit 114,Poles:4No,Volt: 43-280V Dc,Amp:1A , Numerical Differential Relay For Power Transformer Protection Make Ashida,Er/Reputed Make , Master Trip Relay B24,110/125 V Dc Make Er/Reputed , Master Trip Relay B24,220 V Dc Make Er/Reputed , Master Trip Relay 86, Rxmvb2-1Myn563035-Ad Make Abb , Trip Relay Supervision Relay 95 Tsr-1N352-001-As, Make Abb , 33Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt :33Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 66Kv Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt 66Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A , 132 Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt 132Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 220 Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt : 220Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 2 Pole Heavy Duty Rotary Switch With Off 5Amp Make Key Cee Equivalent Etc For C&R Panel , Shunt Tripping/Closing Coil 110V/220V Dc, Suitable For 33Kv Vcb Of Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make,Equivalent Make Etc , Shunt Tripping/Closing Coil 110V/220V Dc,Suitable For 66Kv Sf6 Of Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make,Equivalent Make , Spring/Charging/Closing Coil 220V/110V Dc, Suitable For 33Kv Vcb Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make , Shunt Tripping/Closing Coil 220V Dc(Make Jyoti) ,Suitable For 33 Vcb Of Abb Make , Shunt Tripping/Closing Coil 220V Dc(Make Jyoti) ,Suitable For 132 Sf6 Of Abb Make , Tnc Switch 110/220V Dc 4Ways , Tnc Switch 110/220V Dc 8Ways , Tnc Switch 110/220V Dc 12Ways , Vrla Battery 12V,80/160Ah Along With Charger , Space Heater Sh100w240, Rating:100W 240V Ac Make Apt Control , Resistor Unit For Master Trip Relay 86 Rxtma-1Nrk711004-Aa Make Abb , Geared Motor For 100-130V Dc/Ac 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Geared Motor For 220-250V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Geared Motor For 220-250V Ac For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Spring Charge Motor 230V Ac/Dc , 1.8A, Type Sg105, Insulation Class B, Rpm 60 For 36Kv Vcb Make Agni/Shreem/Reputed Make , Spring Charge Motor 230V Ac/Dc For 36 Kv Megawin Circuit Breaker Type Msp36 , Spring Charge Motor 230V Ac/Dc 2.5A For 132 Kv Sf6 Circuit Breaker (Siemens Make) , Auxilliary Contactor 110V Dc For 36 Kv Megawin Circuit Breaker Type Msp36 , Operating Coil 24V Dc maintenance of For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 maintenance of Opening Coil 48V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Open Coil Mo1(110V-132V Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Open Coil Mo1(220-250V Dc/220V-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Shunt Closing Release-Mc 24V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 Mc Closing Coil(48V Ac-Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mc Closing Coil(110-132V Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mc Closing Coil(220-250V Dc/220-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly 24V Dc Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly 48V Ac- Dc Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly(110-132V Dc/110-127V Ac) Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 Mu Coil Assembly(220-250V Dc/220-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly 24Vcc Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly(48Vca-Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly(110-127Vca/110-132Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly 220-250Vca/220-250Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Shock Absorber Assembly For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Acsr Zebra Conductor , Acsr Panther Conductor , Acsr Moose Conductor , El3 Drive Complete(Operating Mechanism) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Transformer Oil , Motor Operated Change Over Ac240v/Dc220v 100 annual periodical maintenance (Breaker Type) , Singhle Phase 50 C/S, Outdoor Metal Oxide Gapless Type ,30Kv(Rms) Surge Arrester Including Surge Counter/Monitor,Insulating Base Plate And All Associated Assessories Auxilliares , 33Kv Post Insulators Solid Core Type, Power Frequency Withstand Voltage 95Kvp Dry Lightning Impulse Withstand Voltage ± 170 (Kvp) , 132Kv Post Insulators Solid Core Type, Power Frequency Withstand Voltage 275Kvp Dry Lightning Impulse Withstand Voltage ± 650 (Kvp) , Single Phase 50 C/S, Outdoor Metal Oxide Gapless Type, 120Kv (Rms) Surge Arrestor Including Surge Counters/Monitors, Insulating Base All Associated Accessories, Auxiliaries. , Single Phase, 50 C/S 145Kv Current Transformers (900-600-300/1-1-1-1-1 A Or As Per Site Specifications), 31.5Ka For One Second, Rated Dynamic Current 100Ka(Peak), Class A Insulation, Burden 20 Va , Single Phase, 50 C/S 132Kv Capacitor Voltage Transformers (132/√3) Kv/ (110/√3)V, One Min Power Freq Withstand 275Kvrms , Single Phase, 50 C/S 36Kv Current Transformers (1200-600-300 /1-1-1 A Or As Per Site Specifications) , 25Ka For One Second, Rated Dynamic Current 25Ka(Peak), Class A Insulation, Burden 20 Va , Single Phase, 50 C/S Outdoor 33Kv Pt (33/√3) Kv/ (110/√3)V With Highest System Voltage36kv, One Min Power Freq Withstand 70Kvrms , Marshalling Kiosk With Kiosk Frames Mild Steel Structural Sections For Pressed And Shaped Cold-Rolled Sheet Steel, Thickness Not Less Than 2.0 Mm. Frames Shall Be Enclosed In Cold-Rolled Sheet Steel Of Thickness Not Less Than 1.6 Mm. Doors And Covers Shall Also Be Cold Rolled Sheet Steel Of Thickness Not Less Than 1.6 Mm. Complete Structures Shall Be Rigid, Self Supporting, Free From Flows, Twists And Bends. Dust And Vermin Proof Construction And Shall Be Provided With A Degree Of Protection Of Ip: 55, With Copper Bar Earthing. Finishing Paint On Panels Shall Be Of Shade 692 (Smoke Grey) Of Is: 5. The Inside Shall Be Properly Stoved. The Paint Thickness Shall Be At Least 50 Microns , Single Phase 36Kv 50 C/S, Outdoor Metal Oxide Gapless Type, 120Kv (Rms) Surge Arrestor Including Surge Counters/Monitors, Insulating Base All Associated Accessories, Auxiliaries , T&P Items And Safety Equipments , Turn Table For Acsr Panther/Zebra Conductor With Capacity Of 3Mt Made Of Mild Steel With Double Ball Bearing Likely Makes Pee, Zi, Honeywell, Burma Etc , Four Sheeve Pulley Steel Frame Forged Swivel Hookwith Capacity Of 5Mt As Per Is 8610 Pulley Material And Ball Bearing Of Gun Metal Bush With Open Type Pulley Isi Mark Suitable For 12Mm Steel Rope , Bolted Type Come Along Clamp Suitable For Aaac/Panther Conductor 37/3.15Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp Suitable For Aaac/Panther Conductor 37/2.88 Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp Suitable For Zebra Conductor 54/7/3.18Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp For Earth Wire Size 7/3.66Mm Groove According To Size Of Earth Wire Bolts Of High Tensile Steel Likely Makes Pee, Zi, Honeywell, Burma Etc , Snatch Galvanized Pulley Size 6 Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Trans Line Stringing. , Al Alloy Snatch Roller Pulley Size 8Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Trans Line Stringing Likely Makes Pee, Zi, Honeywell, Burma Etc , Snatch Roller Pulley Size 6Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Earthwire Stringing Likely Makes Pee, Zi, Honeywell, Burma Etc , Tool Kit , D-Shackle Heavy Duty , Chain Block Pulley Heavy Duty 5 Ton , Avo Meter Likely Make Motwani, Waco, Riken Etc , Hook On Meter Likely Make Motwani, Waco, Riken Etc , Insulating Hand Gloves Make Crystal Etc Tested For 220 Kv, 132 Kv , 33Kv Level , Safety Helmet Isi Marked , Safety Belt Isi Marked , Safety Vest Isi Marked , Rain Coat Of Duck Back Make Etc , Safety Shoes Of Reputed Make Etc , Fixed Piller Drill Machine 40Mm , Polypropylene Rope ½, ¾& 1 / Garware Make , Manila Rope ¾ & 1 Dia , Steel Wire Rope Sling 16Mm Dia Isi Make 2 Mtr. Long Heavy Duty , Steel Wire Rope Sling 16Mm Dia Isi Make 5 Mtr. Long Heavy Duty , Steel Wire Rope Sling 16Mm Dia Isi Make 10 Mtr. Long Heavy Duty , Steel Wire Rope Of Dia 16 Mm , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 220Kv Voltage Level , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 132Kv Voltage Level , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 33Kv Voltage Level , Hydraulic Conductor Cutter , Hydraulic Compressor Manually Operated For Jointing Aaac/Acsr Conductor With Operating Handle Pressure Gauge, Tools Accessories Kit And Weather Proof Cover For Protection. Capacity: 100 Ton, Make: Techo Scient/Reputed Make. , Hydraulic Compressor Motorised For Jointing Aaac/Acsr Conductor With Operating Handle Pressure Gauge, Tools Accessories Kit And Weather Proof Cover For Protection. Capacity: 100 Ton, Make: Techo Scient/Reputed Make. , Compressor Die Sets Suitable For Above Hydraulic Compressors , Drum Lifting Jack Mechanical 3 Ton Capacity , Single Sheeve Pulley Both Open And Close 5 Ton Capacity , Double Sheeve Pulley 5 Ton Capacity , Three Sheeve Pulley , Petrol Chain Saw Cutter , Earthing Roller , Equilizer Pulleys 10 Ton , Earth Wire Pulley , Single Sheeve Roller Aluminium, Rubberized Dia 300/400 Mm , Single Sheeve Roller Aluminium, Dia 450/600 Mm , Twin Aerial Roller, 150Mm (Rubberized) Aluminium , Twin Aerial Roller, 150Mm (Rubberized) Nylon (P.P) , Patta Clamp , Kitto Clamp , Turn Buckle Capacity 5 Ton , Joint Proctector For Various Conductors , Sagging Winch Machine 10 Ton , Single End Socks , Double End Socks , Earth Wire Socks , Power Winch Machine 5 Mt , Sag Plate , Single Pulley 150Mm Dia (Aluminiun/ P.P) , Automatic Clamp For Conductor/ Opgw , Crow Bar, 30Mm To 32 Mm , Derrick Pole, S-Type Roller , Air Compressor With Ac Single Phase Air Cooled 12 Cfm Compressor And Tank Pressure 100 Psi Make Maxair/Reputed Make , Paint Spray Gun 45Psi , Old Cotton Saree , Digital Mutltimeter (Mutli Functional Meter) , Military Grade Binocular (Reputed Make) Magnification Between 7X To 12 X And Objective Lense Diameter , Axe/Sickle , Professional Chain Saw 58Cc, 20 Inches, 3.75 Hp , Bush Cutting Machine Heavy Duty (Reputed Make) , Meggar , Earth Tester , Digital Insualtion Tester , Earth Test Field Kit , Oil Bdv Kit , Thermovision Camera Having Resolution 640*480, Wavelength 8-14Um, Thermal Sensitivity =0.05°C , Automatic Identification Lens With Manual/Electric/Automatic Focusing, Fov- 25°X19°; High Brightness Sunlight Screen, With 4X Digital Zoom, Hdmi Output, 500Million Pixels, Laser Positioning Points Displayed On The Image,With 32Gb Memory Space, Video Recording, Temp Range: -2O Degree To 650 Degree Centigrade, Having Rechargaeble Liyhium Ion Battery , Primary Injection Kit With 1000 Amperes Rating Accuracy ±0.5% Power Supply(Ac) 220V±10%·25A, 50Hz/60Hz Or 110V±10%·50A, 50Hz/60Hz Current Output (Ac) 1000A·5V Or 500A·10V Capacity 5Kva The Current Output Waveform Distortion ≤5% Dual Protection Overload Electronic Protection And Software Protection Range 0-1100A Resolution 0.1A, Accuracy 0.5%, Secondary Measurement Range 0-6A Resolution 0.001A, Accuracy 0.5%, Current Duration 1000A Range 1000A 2-3Minutes 500A 3-6Minutes 500A Range 500A 2-3Minutes Continuous Output 0-400A With Timer Range 0.0001~999.99S Resolution 0.001S Accuracy 0.2% ±2 Words Standard Standard Iec61010-1;Iec 61326-1 Communication Port Rs232 Cable Length 2X6m, 70Mm² , Cgi Sheet , Spanner Set , Fire Fighting Equipments , Refilling Of Dry Powder 10Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 15Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 25Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 50Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 2Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 5Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 10Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Mechanical Foam Type 50 Ltrs (Make Freeze Fire/Reputed Make) , Refilling Of Co2 Type 4.5 Kg , Refilling Of Co2 Type 10 Kg , Refilling Of Co2 Type 12.2 Kg , Refilling Of Co2 Type 22.5 Kg , Hose Pipe For Dcp 10 Kg , Hose Pipe For Dcp 25 Kg , Hose Pipe For Dcp 50 Kg , Hose Pipe For Abc 2 Kg , Hose Pipe For Abc 5 Kg , Hose Pipe For Abc 10 Kg , Hose Pipe For Mechanical Foam Type 50 Ltrs. , Hose Pipe For Co2 4.5 Kg , Hose Pipe For Co2 22.5 Kg , Wheel Set For Dcp 25 Kg , Wheel Set For Dcp Co2 22.5 Kg , Wheel Set For Dcp/Mechanical Foam 50 Kg , Union Cap For Dcp 10Kg , Union Cap For Dcp 25Kg , Union Cap For Dcp 50Kg , Dry Powder Fire Extinguisher 25 Kg Trolly Mounted Filled With Bc Dry Powder Fitted With Hose Pipe/ Nozzle Is No: 10658 Used On B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Abc Stored Pressure Multipurpose Type Fire Extinguisher 6Kg Wall Mounted Filled With Map Mono Ammonium Phosphate Powder 90% Complete With Hose Pipe/ Nozzle Is No: 14609 Used On A, B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Abc Stored Pressure Multipurpose Typefire Extinguisher 9Kg Wall Mounted Filled With Map Mono Ammonium Phosphate Powder 90% Complete With Hose Pipe/ Nozzle Is No: 14609 Used On A, B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Carbon Dioxidetype Fire Extinguishers Seamless 4.5 Capacity Wheel Type Fitted With Isi Marked Value, Hose/Horn Filled With Co2 Gas Applicable On Class B,C Fires Is 15683 Make Cease Fire,Savemax,Reputed Make , Mechanical Foam 50 Ltrs. Fire Extinguishertrolly Mounted Filled With Afff Concentrate Fitted With Hose Pipe/ Nozzle Is No: 13386 Used On A & B Class Of Fire Make Cease Fire,Savemax,Reputed Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
27.
Tourism #11133087 Technical Bid
Tender for Supply, Installation, Testing And Commissioning Of Inverter Type Split Ac Units In It And Crc Sections At Ktdc Corporate Office, Thiruvananthapuram , Supply Installation Testing and Commissioning of Split Ac Units , Supply, Installation, Testing And Commissioning Of Following Capacity Split Type Inverter High Wall Mounted Air Conditioner Unit With Cordless Remote Including Fixing Of Indoor & Outdoor Units, Initial Gas Charging As Per Manufacturer Standards, Giving Power Connection To Nearest Power Plug Point / Mcs, Connecting Indoor And Outdoor Units Using Hard Drawn Copper Refrigerant Pipes Insulated With Nitrile Rubber Or Equivalent Material Of Minimum 3 Mtrs, Pvc Insulated Flexible Copper Cable Of Minimum 3 Meters As Per Original Manufacturers Standards, Necessary Drain Water Line Using 20Mm Pvc Pipe Minimum 3 Mtrs. Necessary Opening On Wall Shall Be Made For Drawing Refrigerant / Power / Drain Lines And Shall Be Restored To Normal Using Cement Plastering. (Drain Pipe Line Shall Be Properly Fixed And Clamped To Line And Level As Per The Direction Of Site Engineer In Charge). Make: Bluestar/Daikin/Panasonic/O General/Carrier. 1.5Tr Capacity Inverter Type 5 Star Or Above Rated Working On Single Phase 240 V, 50 Hz +/-1% Ac Supply With 20A Plug Top, Code Etc. Including All Accessories Etc.Complete , Supply And Fixing Wall Mounting Type 4 Kva Or Higher Required Capacity Voltage Stabilizer Designed For Air Conditioning Load Working On 240V, 50Hz Single Phase Ac Supply To Feed Output Voltage At +/- 10% Tolerance With Automatic Low Voltage High Voltage Cutoff, Built In Thermal Overload Protection, Powder Coated, Enclosure Etc. Complete Good Quality And Approved Make And Giving Connection. (Approved Make: V Guard Or Equivalent Reputed Brand) , Supply And Providing Additional Refrigerant Lines (Both Suction And Discharge) Using Hard Drawn Copper Pipe Of The Sizes Recommended By The Manufacturer Including Suitable Thickness Nitrile Rubber Thermal Insulation Of Good Quality To Extend The Refrigerant Gas Connection Till Outdoor Unit As Required At Site. , Supply And Drawing Additional Control Cabling Of Required Size As Per Manufacturer Specification In Between Indoor And Outdoor Units. 4C X 2.5 Sq Mm Flexible Copper Wire , Supply And Laying Additional Cpvc Drain Pipe Of Good Quality And Suitable Size To Extend Water Drain Connection Till Nearest Silt Terminal As Required At Site. , Supply And Providing Good Quality Stand For Mounting The Outdoor Units With All Accessories And Making Good Any Damages Caused Etc. Complete. , Buy Back Of Existing 1.5 Tr Split Ac Unit Installed In Crc Section (Not Working) , Buy Back Of Existing 2 Nos Of 1.5Tr Split Ac Units (Make: Samsung) Installed In System Analyst Cabin And It Section At Corporate Office In Working Condition
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
29.
Petroleum and Natural Gas #11114647 Technical Bid
Tender for Supply , Supply Of Abb Make Di818 Digital Input Module (32-Channel, 24 V Dc) Along With Required Terminal Bases, Relays And Barriers For Digital Signals And Accessories Consisting Of Abb Make Tu818 Compact Terminal Base (50 V) For Field Wiring Termination And Modulebus Distribution, Abb Make Ci840a Profibus Dp-V1 Interface Module For Communication Integration, And Abb Make Tu847 Terminal Base For Ci840 To Provide Profibus Termination And Backplane Connectivity, Supplied As A Complete Compatible Assembly For Integration With 800Xa Based Dcs System. , Supply Of Abb Make Do818 Digital Output Module (32-Channel, 24 V Dc) Along With Required Terminal Bases, Relays And Barriers For Digital Signals And Accessories Consisting Of Abb Make Tu818 Compact Terminal Base (50 V) For Field Wiring Termination And Modulebus Distribution, Abb Make Ci840a Profibus Dp-V1 Interface Module For Communication Integration, And Abb Make Tu847 Terminal Base For Ci840 To Provide Profibus Termination And Backplane Connectivity, Supplied As A Complete Compatible Assembly For Integration With 800Xa Based Dcs System. , Supply Of Pm867 Redundant Processor Unit Along With Required License And All Essential Controller-Level Hardware, Sm812 Safety Module With Required License And Software For High-Integrity Safety Processing, Bc810 Cex Bus Interconnection Unit For Establishing Communication Between The Main Controller And Installation Of Clusters, Ci867 Redundant Modbus Tcp/Ip Interface Module Along With Required License For Reliable Third-Party System Communication, Tb840 Redundant Optical Module Bus Cluster Modem For Long-Distance Fiber-Optic Cex Connectivity, Tu848 Termination Unit For Tb840 Optical Module Bus Cluster Modem , K811 Pof Cables Required For Providing The Optical Communication Link Between Controller And Remote Installation Of Station For The Abb Esd Plc System. , Supply Of Ai880 High Integrity Redundant Analog Input Module (8 Channels, Sil3 Certified) Along With Tu844 Mtu For Secure Wiring And Module Termination Of Redundant Analog Installation Of Signals, Barriers For Analog Signals And Ty801 Shunt Stick To Facilitate Loop Testing, Simulation, And Maintenance Of Analog Field Instruments For Integration With The Abb Esd Plc. , Supply Of Abb Make Di880 High Integrity Redundant Digital Input Module (16-Channel, Sil3 Certified) Along With Required Terminal Bases,Relays And Barriers For Digital Signals,Line Monitoring Relay And Accessories Consisting Of Abb Make Tu842 Terminal Base/Mtu For Redundant Digital Installation Of Modules , Providing Field Wiring Termination, Redundant Modulebus Connection, And Backplane Interface, Supplied As A Complete Compatible Assembly For Integration With Abb Esd Plc. , Supply Of Abb Make Do880 High Integrity Redundant Digital Output Module (16-Channel, Sil3 Certified) Along With Required Terminal Bases, Relays And Barriers For Digital Signals And Accessories Consisting Of Abb Make Tu842 Terminal Base/Mtu For Redundant Digital Installation Of Modules, Providing Field Wiring Termination, Redundant Modulebus Connection, And Backplane Interface, Supplied As A Complete Compatible Assembly For Integration With The Abb Esd Plc. , Supply Of 42U Rack Enclosure Cabinet For Marshalling/System Cabinet, Along With Sd834 20A Industrial Power Supply Units And Ss823 Power Voting Units To Ensure Redundant, Uninterrupted Power Delivery And Accessories Like Limit Switches, Fftdu, Earthing Arrangements, Breaker, Spd Type 1+2,Fuses, Liu, Media Converter, Terminal Blocks, Required Interpanel Cables And Connectors, Earthing Cables, Power Cables, Wiring Etc Complete As Per Specification. , Supply Of Ups Power Distribution Board Panel With Accessories For Powering Panels And Any Other Tas Equipments Where Ups Power Are Required For Smooth Un-Interrupted Operation. Miscellaneous Instrumentation Comprising Of Suitable Mccbs For Isolation, Mcb Etc Are To Be Provided. The Panel Shall Be Complete In All Respects With Necessary Indication Lamps For Powering, Necessary Control Wiring With Digital Voltmeter & Digital Ammeter Separately For Ups And Auxilliary Supply For Front And Rear Seperately Etc. , Services , Installation, Integration, Testing And Commissioning Of Abb Make Di818 Digital Input Module (32-Channel, 24 V Dc) Along With Required Terminal Bases And Accessories Consisting Of Abb Make Tu818 Compact Terminal Base (50 V) For Field Wiring Termination And Modulebus Distribution, Abb Make Ci840a Profibus Dp-V1 Interface Module For Communication Integration, And Abb Make Tu847 Terminal Base For Ci840 To Provide Profibus Termination And Backplane Connectivity, Supplied As A Complete Compatible Assembly For Integration With 800Xa Based Dcs System. , Installation, Integration, Testing And Commissioning Of Abb Make Do818 Digital Output Module (32-Channel, 24 V Dc) Along With Required Terminal Bases And Accessories Consisting Of Abb Make Tu818 Compact Terminal Base (50 V) For Field Wiring Termination And Modulebus Distribution, Abb Make Ci840a Profibus Dp-V1 Interface Module For Communication Integration, And Abb Make Tu847 Terminal Base For Ci840 To Provide Profibus Termination And Backplane Connectivity, Supplied As A Complete Compatible Assembly For Integration With 800Xa Based Dcs System. , Installation, Integration, Testing And Commissioning Of Pm867 Redundant Processor Unit Along With Required License And All Essential Controller-Level Hardware, Sm812 Safety Module With Required License And Software For High-Integrity Safety Processing, Bc810 Cex Bus Interconnection Unit For Establishing Communication Between The Main Controller And Installation Of Clusters, Ci867 Redundant Modbus Tcp/Ip Interface Module Along With Required License For Reliable Third-Party System Communication, Tb840 Redundant Optical Module Bus Cluster Modem For Long-Distance Fiber-Optic Cex Connectivity, Tu848 Termination Unit For Tb840 Optical Module Bus Cluster Modem , K811 Pof Cables Required For Providing The Optical Communication Link Between Controller And Remote Installation Of Station For The Abb Esd Plc System. , Installation, Integration, Testing And Commissioning Of Ai880 High Integrity Redundant Analog Input Modules (8 Channels, Sil3 Certified) Along With Tu844 Mtu For Secure Wiring And Module Termination Of Redundant Analog Installation Of Signals, Barriers For Analog Signals And Ty801 Shunt Stick To Facilitate Loop Testing, Simulation, And Maintenance Of Analog Field Instruments For Integration With The Abb Esd Plc. , Installation, Integration, Testing And Commissioning Of Abb Make Di880 High Integrity Redundant Digital Input Modules (16-Channel, Sil3 Certified) Along With Required Terminal Bases,Relays And Barriers For Digital Signals,Line Monitoring Relay And Accessories Consisting Of Abb Make Tu842 Terminal Base/Mtu For Redundant Digital Installation Of Modules , Providing Field Wiring Termination, Redundant Modulebus Connection, And Backplane Interface, Supplied As A Complete Compatible Assembly For Integration With Abb Esd Plc. , Installation, Integration, Testing And Commissioning Of Abb Make Do880 High Integrity Redundant Digital Output Modules (16-Channel, Sil3 Certified) Along With Required Terminal Bases, Relays And Barriers For Digital Signals And Accessories Consisting Of Abb Make Tu842 Terminal Base/Mtu For Redundant Digital Installation Of Modules, Providing Field Wiring Termination, Redundant Modulebus Connection, And Backplane Interface, Supplied As A Complete Compatible Assembly For Integration With The Abb Esd Plc. , Installation, Integration, Testing And Commissioning Of 42U Rack Enclosure Cabinet For Marshalling/System Cabinet, Along With Sd834 20A Industrial Power Supply Units And Ss823 Power Voting Units To Ensure Redundant, Uninterrupted Power Delivery And Accessories Like Limit Switches, Fftdu, Earthing Arrangements, Breaker, Spd Type 1+2,Fuses, Liu, Media Converter, Terminal Blocks, Required Interpanel Cables And Connectors, Earthing Cables, Power Cables, Wiring Etc Complete As Per Specification. , Installation, Integration, Testing And Commissioning Of Ups Power Distribution Board Panel With Accessories For Powering Panels And Any Other Tas Equipments Where Ups Power Are Required For Smooth Un-Interrupted Operation. Miscellaneous Instrumentation Comprising Of Suitable Mccbs For Isolation, Mcb Etc Are To Be Provided. The Panel Shall Be Complete In All Respects With Necessary Indication Lamps For Powering, Necessary Control Wiring With Digital Voltmeter & Digital Ammeter Separately For Ups And Auxilliary Supply For Front And Rear Seperately Etc.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Maharashtra View Result →
Contract Date: May 19, 2026 Contract Value : 1.23 Crore
Boards / Undertakings / PSU No of Bidders 3
31.
Communications and Information Technology  #11104520 AOC
Tender For supply installation testing and commissioning Of It Infrastructural Items, Cctv Surveillance System, Epabx And Voice N/W, Audio Visual Solution For The Conference And Training Room At Igr Office, In The Stp-Ii.- 1 Description 2 SITC of IP 4MP IR Bullet Camera (complete with Centralised VMS perpetual license) with Motorized Varifocal lens having minimum technical specification: Image Sensor: 1/2.8” Progressive Scan CMOS; Min. Illumination: Color: 0.01 lux @(F1.2-1.7, AGC ON), 0.01 lux @(F1.2-1.7, AGC ON), 0 lux with IR; Shutter Speed: 1/3 s to 1/100,000 s; Day & Night: IR Cut Filter; 3-Axis Adjustment Pan; Digital Noise Reduction: 3D DNR; WDR: 120dB; Focal length: 2.7 to 13.5 mm; View Angle: Horizontal FOV: 90°, Vertical FOV: 60°; Aperture: F1.2 to F1.7 with Auto focus; Lens Mount: Ø14; IR Range: 50 m or higher; Video Compression Main stream: 3-Line, H.265+/H.265/H.264+/H.264/MJPEG; Video Bit Rate: 128 Kbps to 8 Mbps; Operating Conditions Temperature: -30 °C to +60 °C; Power Supply: 12 VDC, PoE (802.3af); Material: Metal; Protection Level: IP66, IK10, Lightning Protection, Surge Protection and Voltage Transient Protection. REGULATORY: CE, FCC, UL, ONVIF, BIS; Including Centralised VMS Software License & pole Mounting Bracket for Camera (if required as per site). Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 3 SITC of IP 4MP IR Dome Camera (complete with Centralised VMS perpetual license) with Motorized Varifocal lens having minimum technical specification: Image Sensor: 1/2.8” Progressive Scan CMOS; Min. Illumination: Color: 0.01 lux @(F1.2-1.7, AGC ON), 0.01 lux @(F1.2-1.7, AGC ON), 0 lux with IR; Shutter Speed: 1/3 s to 1/100,000 s; Day & Night: IR Cut Filter; 3-Axis Adjustment Pan; Digital Noise Reduction: 3D DNR; WDR: 120dB; Focal length: 2.7 to 13.5 mm; View Angle: Horizontal FOV: 90°, Vertical FOV: 60°; Aperture: F1.2 to F1.7 with Auto focus; Lens Mount: Ø14; IR Range: 50 m or higher; Video Compression Main stream: 3-Line, H.265+/H.265/H.264+/H.264 /MJPEG; Video Bit Rate: 128 Kbps to 8 Mbps; Operating Conditions Temperature: -30 °C to +60 °C; Power Supply: 12 VDC, PoE (802.3af); Material: Metal; Protection Level: IP66, IK10, Lightning Protection, Surge Protection and Voltage Transient Protection. REGULATORY: CE, FCC, UL, ONVIF, BIS; Including Centralised VMS Software License & pole Mounting Bracket for Camera (if required as per site).Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 4 SITC of 16 Channel IP 4K NVR having minimum technical specification: Video Input: 32 Channel IP Fully Featured NVR; Audio Iuput/Output: 1 Channel Input/2 Channel Outputs, RCA; Display Interface: 2 HDMI (1 HDMI up to 3840 × 2160); 2 VGA; Display Split: 1/4/8/9/16/25/36/64; OSD: Camera title; Time; Video loss; Camera lock; Motion detection; Recording; Compression: H.265/H.264/MJPEG/MPEG4; Resolution: 12 MP (4000 × 3000); 8 MP (3840 × 2160); 6 MP (3072 × 2048); 5 MP (2560 × 1920); 4 MP (2560 × 1440); 3 MP (2048 × 1520); 1080p (1920 × 1080); 720p (1280 × 720); D1 (704 × 576 / 704 × 480); CIF (352 × 288 / 352 × 240); Frame Rate: 1–15 fps (12 MP and 8 MP); 1–25/30 fps (rest of the resolutions); Record Bit Rate: 256Mbps or 200Mbps(when RAID is enabled); Bit Rate: 16 kbps ~ 20 Mbps, per channel; Network Throughput: Input 256Mbps or 200Mbps (when RAID is enabled); Output 256Mbps or 200Mbps (when RAID is enabled); Cascading: Built-in CMS to Monitor and Manage Multiple Matrix NVRs; ONVIF and Major Camera Brands Support; Usb Port: 4; RS232: 1 port (for PC communications and keyboard). Temperature: -10 ºC ~ +55 ºC; REGULATORY: CE, FCC, UL, ONVIF, BIS; Including Wireless Bluetooth Multi Device Keyboard and Mouse. Centralised VMS perpetual license.Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 5 SITC of Non-Touch Commercial LED UHD Display (Indoor Type) having minimum technical specification Size (diagonally): 55-inch or higher; Effective Display Area (W x H): as per OEM; Panel Technology: Vertical Alignment, Type: IPS Panel/D- LED/Edge LED, Resolution: 3840 x 2160 pixels @ 50 Hz or higher, Aspect Ratio: 16:9, Colors: 2 Million Colors or higher; Brightness: 350cd/m^2 or nits or higher, Contrast Ratio (Static): 1100:1, Viewing Angle: 178° Vertical / 178° Horizontal Display; Response Time: 8 ms(Typ) or less, Operation Hour: 24Hr x 7; Frequency: 50Hz ± 2% or better, Audio: 20Watt (10W + 10W); Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 6 SITC of Hard Disk .Spec Surveillance Grade HDD of minimum 7200 rpm for storage 8TB storage capacity.Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 7 SITC of: Business Communication System with all necessary power accessories: EPBAX system with line: 4 Trunk, 8 Digital & 48 Line Analog Extensions, Expendable up to 96 Analog Extensions with all necessary power accessories; Other Faetures: Hotline, Live Call Supervision, Auto Call Back, Automatic Call, Disconnector, Auto Redial,Call Splitting, Call Conference, Direct Inward Dialing, External Call Forwarding, Executive/ Secretary etc. 8 SITC of Digital Telephone Set 9 SITC of Analog CLI Telephone Set. 10 SITC of: 5 pair Un-armoured Telephone Cable {0.5mm.Dia (Minimum)} 11 SITC of: 200 Pair MDF with original Krone Module with 20 SWG GI Sheet Steel Box Enclosure complete WITH ALL ACCESSORIES. 12 SITC & Laying of PVC conduits(ISI marked) laying through surface with all accessories as required FOR THE ENTIRE SYSTEM WITH ALL OEM ACCESSORIES. (Quality: MMS; Ø=25mm) Quality : ISI, Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 13 SITC of ceiling speaker 2 Way, Acoustic Suspension ceiling mount speakers with superior sound quality. Components: LF: 8cone driver; HF: 1 soft dome; Frequency range (-10dB): 55Hz - 20kHz; Nominal coverage: H x V: 100° conical; Power rating: 180W PGM; Transformer taps: 60W, 30W, 15W @ 100V; Sensitivity (1W; 1m on axis): 90dB SPL; Peak: 116dB SPL; Certificate: CE, RoHS; Color- White. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 14 SITC of Multichannel Power Amplifier Output power : 1kHz (THD +N=1%: 4Ω/8Ω) 140W x 4 , Frequency response : 0dB, ±1.0dB (RL=8Ω, 100V/70V, Po=1W, 20Hz - 20kHz) , S/N ratio : ≥ 100dB(A-weighted) , Crosstalk : ≤ -60dB. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 15 SITC of column array speaker Full-range, Bass reflex type slim line array/ column array speaker with 8 x 1.5” Cone; Frequency range (- 10dB): 81 Hz – 20 kHz; Nominal coverage: H x V: 170° x 25° - 30°; Power rating: 160 W PGM; Sensitivity (1W; 1m on axis): 91 dB SPL; Peak: 116 dB SPL. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 16 SITC of Multichannel Power Amplifier Output power 1kHz Non-clip 20msec Burst Both channels driven 300W x 2 @ 8Ω & 2Ω and 500W @ 4Ω; Sampling frequency rate: 48kHz; A/D D/A Converters: AD/DA: 24-bit linear, 128 times over sampling; THD: 0.1% (1kHz, 10W), 0.3% (1kHz, Half power); Frequency response: ±1.0dB (1W, 8Ω, 20Hz to 20kHz); Input impedance: 20kΩ (Balance), 10kΩ (Unbalance); I/O Connectors: Speaker output: Neutrik speakON NL4 x2, Binding post x2 pairs, 1/4 PHONE(TS) x2; Line Input: XLR-3-31 x2, 1/4 PHONE(TRS) x2; Inbuilt Load protection, Amplifier protection & Power supply protection. 17 SITC of Digital Signal Processor Sampling frequency rate Internal 48kHz/44.1kHz ; Signal delay : 1.9 msec (AD-DA @48kHz), Total harmonic distortion : “0.05% (+4dBu, Gain:-6dB, 48kHz) 0.1% (+4dBu, Gain: +66dB, 48kHz)” (Measured with a 18dB/Oct filter @80kHz) ; YDIF In YDIF RS-422 16IN RJ45 , YDIF Out YDIF RS-422 16OUT RJ45 ; GPI 16IN / 8OUT IN 0V-5V,(IN 16 L(0V-2.5V)/H(2.5V-24V)), Output channel functions : Room Delay, Room EQ, Speaker Processor, X-Over (1way,2way), Delay, 6-band PEQ, Limiter, AEC. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 18 SITC of Digital Control panel 1 Volume & 4 Switch equipped Wall Mounut Control panel for DSP ; Easy connection by CAT5 carrying RS485 + power.Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 19 SITC of Ceiling Microphone Frequency response: 160Hz – 16kHz(- 10dB) or better; Sampling Rate: 48kHz; Bit depth: 24bit; Latency: 60 [ms] (including signal processing) or lower; Audio I/O Dante: 1in x 2out, In1=AEC reference signal/Out1=output of beam mix, Out2= output of beam mix (simple processed); Maximum input level of SPL: 117.8 dB SPL; Self Noise: -0.8 dBA SPL; SNR(Ref. 94 dB SPL at 1 kHz): 94.8 dBA; Sensitivity: -23.8 dBFS/Pa; Dynamic Range: 118.6 dBA; Signal Processing: Multi beam tracking, Adaptive Echo Canceler, Noise Reduction, Dereverberation, Auto Mixer, Auto Gain Control, Parametric EQ, Output Gain; Power requirements: PoE(IEEE 802.3af), DC 48V; Indicator: Front Indicator(Mute/Unmute & Status) ・Network Port Indicator. (Ceiling Mic & DSP Should be from Same OEM) . Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 20 SITC of L2 Switch for stable operation of a Dante network with Standard IEEE 802.3 (10BASE-T/100BASE-TX/1000BASE-T); Number of ports: 10 Ports; Communication mode: Auto negotiation; Connector type: RJ-45; LAN ports: IEEE 802.3 (1000BASE-T) 2 ports; 8 ports (1-8) PoE Power Supply; PoE Standards: IEEE 802.3at; Max power supply per port: 30 W. 21 SITC of FHD 20x PTZ camera 1080p @ 60 frames per second PTZ Camera with minimum 20X Optical Zoom and FoV of minimum 57 deg, min 100 Presets.Camera should support simultaneous outputs through Ethernet, HDMI, 3G-SDI, Audio In and can be controlled via RS232 & 422 In & Out & IP.Panning angle -170° ~ +170°, Tilting angle -30° ~ +90° . The tilting and panning speed of camera should be minimum 300° per second. Camera should support SRT, FreeD Protocol, PoE and Virtual USB Driver. OEM should be CE, FCC, RoHS & BIS Certified. Warranty: 03 (Three) onsite comprehensive OEM warranty with parts and service. 22 SITC of 86 UHD LED Interactive Display 86, 4K Multi touch interactive display, 450 cd/m2 Panel Technology- IPS, ,Android Pie 11.0, 8 GB Memory, 128 GB storage, Built in Wifi & Bluetooth, 2x20 W - Front Facing Speakers, Continuous Touch Points: 40 Points: Windows,10 Points: Android. Rear port terminals: 4 x HDMI IN, 1 x VGA, 2 x USB 2.0 Type A, 1 x USB 2.0 Type C, 1 x Micro SD, 1 x secure slot (USB 2.0), 1 x OPS slot (15W), 1 x HDMI Out, 1 x RJ45. Front Port Terminals: 2 x USB2.0 Type-A, 1 x USB2.0 Type-B for touch, 1 x HDMI2.0 Input, Capability to connect & disconnect all devices / group of devices from central location. Application have capability to share and finish casting of BYOD device and have a robust authorization management. Power off & Reboot devices from central location also control external devices such as USB cameras, Speakers, control brightness & clear cache. Device active trend and deactive displays, Writing, Pen, Palm Eraser, Save, Screen Capture, Storage and Tool Bar. Supports 3rd party applications, recording feature, USB WEB Cam Compatible, Support PPT, Word, PDF, Image, Video Play, 24x7 operation, with OPS i5, 8GB RAM, 256GB SSD. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 23 SITC of 32 HD Display 32 FHD Ready resolution Android LED display Brightness-500 Nits, Operating Hours- 24x7,with built in 2.4 Ghz Wifi, 1 Ghz Built in Quad core processor, 1.5 GB DDR3 RAM, 8 GB Memory, built in Triple Mali 600 MHz GPU, with 2K HDR, Dolby Audio, Built in Wifi and Chromecast, Built in web browser, HDMI CEC, HDMI ARC, , 20W built in speakers, HDMI 2.0 X 3, AV X 1, USB 2.0 X 1, RJ45 X 1, Headphone Out x 1, SPDIF Out x 1 , RS232CX1. 24 SITC of UHD+ 4x4 HDMI Matrix with Audio Output HDMI input and output with 18Gbps (600MHz) 4K UHD support; DVI 1.0 compliant with the use of an HDMI-DVI adaptor; Supports HD resolutions up to 3840x2160@60 Hz (YUV 4:4:4, 8-bit) & 4096x2160@60 Hz (YUV 4:4:4, 8-bit); Supports 16-bit Deep Color up to 1080p60; Input Port: 4 HDMI; Output Port 4 HDMI, 4 Stereo Audio ( 3.5mm ); HDMI Compliance: HDMI 2.0 (DVI 1.0); HDCP Compliance: 2.x; Input Signal Types: 4096x2160p @ 60 8-bit YUV 4:4:4, HDR 10; Output Signal Types: 4096x2160p@60 8-bit YUV 4:4:4, HDR 10. Warranty: 02 (Two) years onsite comprehensive OEM warranty with parts and service. 25 SITC of Wireless Presenter Operating system Windows 10 and higher macOS 11 (BigSur) and higher Android v9 and higher; Video outputs 4K UHD (3840*2160) @ 30Hz. HDMI 1.4b or USB-C DisplayPort 1.2 (only Gen2); USB: 1 X USB-A, 1 X USB-C ClickShare Buttons 2, Desktop & Mobile Native protocols: Airplay, Google Cast, Miracast* Maximum number of simultaneous connections (with Buttons and/or App): 32; Noise Level: Max. 25dBA @ 0-30°C Max. 30dBA @ 30-40°C Authentication protocol WPA2-PSK in stand alone mode WPA2-PSK or IEEE 802.1X, Wireless transmission protocol IEEE 802.11 a/g/n/ac and IEEE 802.15.1; Reach: Adjustable with signal strength modulation; max. 30m (100 ft),Frequency band: 2.4 GHZ and 5 GHz. including 2 additional buttons. 26 SITC of 1.5 sq mm Speaker Wire: 27 SITC of CAT6 Cable: 28 SITC of 15/10/5/2/1 mtr HDMI Cable- as required 29 SITC of AUDIO Cable 30 SITC of 10 mtr USB Cable 31 SITC of 25mm PVC Conduit/Casing/Raceway with accessories 32 SITC of Connectors & Interconnects 33 Mics - installation accessories 34 SITC of Digital Podium with 20 or bigger touch display & gooseneck microphone All-in-one Podium with Podium body made from 1.5mm thick CRCA steel, duly powder coated, with security lock cover for Touch display max size 24 Diagonal. With Keyboard tray housing, Mouse, Drawer for doc cam, space for keeping extra laptop/tablet, Gooseneck mic with switch, W/o Central Controller, 360 degree heavy duty movable castor, Open from Front & Back for easy installation, Adjustable Rack, Ample ventilation.Multimedia Controller with Control out put, Multiple input & switchable output. Warranty: 01 (ONE) years onsite comprehensive OEM warranty with parts and service. 35 SITC of Wall Speaker SITC of Wall Mount Speaker with all necessary accessories, having minimum technical specification: System Type: Full range, Acoustic suspension; Components: 3.5 full range; Frequency Range (-10dB): 130Hz-20kHz; Coverage Angle (Horizontal x Vertical): 150° x 160°; Nominal Impedance: 8Ω; Power Rating: 40W; Sensitivity (1W, 1m): 86dB SPL; Maximum SPL (Caluculated, 1m): 105dB SPL; Connectors: 1x Euroblock (4P) (Input: +/-, Loop Thru:+/-); Material, Finish, Color: Black, White; Accessories: Owners Manual, Retaining knob, Terminal cover screw, Wall / Ceiling mount bracket, Terminal cover. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 36 SITC of Mixer Amplifier Output Power : 120W x 2 (20ms Burst) ; Total harmonic distortion : ≤0.2% (Line in to Speaker out, Half power @1kHz, 3Ω/4Ω/8Ω), ≤0.2% (Line in to Speaker out, Half Power @1kHz, 70V/100V, 120W/200W) ; Crosstalk : ≤ -70dB (MIC/LINE input to other MIC/LINE input) ; Mic/Line Input : Input 1-6: 3.5mm Euroblock (6-pin, balanced) x 3. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 37 SITC of 65 4K display: 65 4K UHD (3840x2160 Ready resolution , Brightness-350 Nits, Operating Hours- 24x7,Built in Android OS LED display with built in 2.4 Ghz Wifi, 1.1 Ghz Built in Quad core processor, 2 GB DDR3 RAM, 16 GB Memory, built in Triple Mali 600 MHz GPU, with 2K HDR, Dolby Audio, Built in Wifi and Chromecast, Built in web browser, HDMI CEC, HDMI ARC, 20W built in speakers, HDMI 2.0 X 3, AV X 1, USB 2.0 X 1, RJ45 X 1, Headphone Out x 1, SPDIF Out x 1 , Haze-28%, RS232CX1. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 38 SITC of 43 4K UHD (3840x2160) Display Supply, Installation, Testing and Commissioning of 43 4K UHD (3840x2160) Ready resolution Built in Android OS LED display with brightness- 500 Nits, Operating Hours 24x7, built in 2.4 Ghz Wifi, 1.1 Ghz Built in Quad core processor, 2 GB DDR3 RAM, 16 GB Memory, built in Triple Mali 600 MHz GPU, with 2K HDR, Dolby Audio, Built in Wifi and Chromecast, Built in web browser, HDMI CEC, HDMI ARC, 20W built in speakers, HDMI 2.0 X 3, AV X 1, USB 2.0 X 1, RJ45 X 1, Headphone Out x 1, SPDIF Out x 1 , RS232CX1, Haze-28%. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 39 SITC of UHD+ 4x4 HDMI Matrix with Audio Output HDMI input and output with 18Gbps (600MHz) 4K UHD support; DVI 1.0 compliant with the use of an HDMI-DVI adaptor; Supports HD resolutions up to 3840x2160@60 Hz (YUV 4:4:4, 8-bit) & 4096x2160@60 Hz (YUV 4:4:4, 8-bit); Supports 16-bit Deep Color up to 1080p60; Input Port: 4 HDMI; Output Port 4 HDMI, 4 Stereo Audio ( 3.5mm ); HDMI Compliance: HDMI 2.0 (DVI 1.0); HDCP Compliance: 2.x; Input Signal Types: 4096x2160p @ 60 8-bit YUV 4:4:4, HDR 10; Output Signal Types: 4096x2160p@60 8-bit YUV 4:4:4, HDR 10. Warranty: 02 (Two) years onsite comprehensive OEM warranty with parts and service. 40 SITC of Wireless Lapel Mic: 24 MHz bandwidth 8 frequency banks with each 12 presets, Mute button for full speech control Synchronization via RF remote channel, High-quality true diversity reception, Pick-up pattern tobe cardioid, Automatic frequency scan feature searches for available frequencies, Frequency response (microphone) 80 - 16000 Hz, Dynamic microphone with Cardioid Dynamic Capsule, Sound pressure level (SPL) 149 dB(SPL) max THD, total harmonic distortion < 1 %, RF output power 10 mW, Transducer principle to be permanently polarised, AF sensitivity 1,5 mV/Pa, Signal-to-noise ratio> 103 dB(A). Warranty: 02 (Two) years onsite comprehensive OEM warranty with parts and service. 41 SITC of Wireless Handheld Mic 24 MHz bandwidth: 8 frequency banks with each 12 presets, Mute button for full speech control Synchronization via RF remote channel, High-quality true diversity reception, Pick-up pattern tobe cardioid, Automatic frequency scan feature searches for available frequencies, Frequency response (microphone) 80 - 16000 Hz, Dynamic microphone with Cardioid Dynamic Capsule, Sound pressure level (SPL) 149 dB(SPL) max THD, total harmonic distortion < 1 %, RF output power 10 mW, Transducer principle to be permanently polarised, AF sensitivity 1,5 mV/Pa, Signal to-noise ratio> 103 dB(A). Warranty: 02 (Two) years onsite comprehensive OEM warranty with parts and service. 42 SITC of Small format PC for Podium with dual HDMI output: 43 SITC of Ceiling/Wall Brackets for Displays 44 SITC of 1.5 sq mm Speaker Cable: 45 SITC of CAT6 Cable: 46 SITC of 15/10/5/2/1 mtr HDMI Cable- as required 47 SITC of AUDIO Cable 48 SITC of 25mm PVC Conduit/Casing/Raceway with accessories 49 SITC of Connectors & Interconnects
Contract Date: May 17, 2026 Contract Value : 57.09 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
32.
Power #11101736 Technical Bid
Tender for Procurement Of Spares For Various Rotork Make Electrical Actuators For Stps, Sarni , Common Spares For Rotork Make Actuators , Open / Stop / Close Knob Assly (Control Spindle) , Local / Remote Knob Assly (Isolator Spindle) , Basic Set Loom Assly , P.B Cover Assy Wt , Terminal Block 64 Terminals (Wt & Flp) , Folomatic Card , Timing Belt , L/P Relay Assly , Syncro Pak Assy With Housing (Wt) With 23A Contactor Assy , Inter Posing Relay For Basic S Pack , Olr Indication , Epoxy Basic Switch ( 2 No + 2 Nc ) Long Lead , Main Pcb (Mk Vii) , Contactor Assy (12 A) , Power Module Assy , Limit Switch Mechanism , Aux Switch 1 No + 1 Nc Changeover , Aux Switch 2 No + 2 Nc , Loom For Pb Assembly , Switch Mechanism Assy With Ind Wt , Indication Lamp Set , Current Position Transmitter 2/3 Wire , Terminal Block Assembly Wt , Contactless Cpt For K Range Actuators , Spares For K30f10a / K60f10e , Disc Spring Set , Oil Seal & Oring Kit , Hand Wheel Retainer , H/Wheel Thrust Washer , Felt Seal Kit , Screwed Collar , Yoke Return Spring Set , Stud And Nut (1 Set) B5 , Vane Module , Spares For K600g1/G2 A , Lsd Shaft , Lsd Retainer , Complete Bearing Set , Disc Spring Set , Oil Seal & Oring Kit , Handwheel Retainer , H/Wheel Thrust Washer , Felt Seal Kit , Screwed Collar , Yoke Return Spring Set , Stud And Nut (1 Set) B5 , Vane Module , Spares For K1000g3 , Complete Bearing Set , Disc Spring Set , Oil Seal & Oring Kit , Handwheel Retainer , H/Wheel Thrust Washer , Felt Seal Kit , Screwed Collar , Yoke Return Spring Set , Stud And Nut (1 Set) B5 , Vane Module
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Madhya Pradesh View Result →
33.
Educational and Research Institute #11098868 AOC
Tender For Iehe Bhopal Invites Online Tender For Supply Of Sound System In The Institute , Sound System , Wall Mount Cabinet Loudspeaker General Requirements: The Loudspeaker Shall Be A Cost-Effective, 12W General-Purpose Cabinet Speaker Designed For Indoor Surface-Mount Applications. It Must Be Suitable For Both High-Quality Speech Intelligibility And Background Music Reproduction Acoustic Performance: Rated Power: 12W, With Adjustable Power Tappings At 12W, 6W, And 3W To Allow For 3 Db Step Adjustments. Sound Pressure Level (Spl): Must Provide A Maximum Special Of 102.0 Db At 6W/1M (1 Khz) And A Sensitivity Of 91.7 Db At 1W/1M (1 Khz). Frequency Range: The Effective Frequency Range Shall Be From 150 Hz To 15 Khz. Opening Angles: Horizontal: 184° (1 Khz) / 86° (4 Khz). Vertical: 66° (1 Khz) / 58° (4 Khz). Electrical Specifications: Input Voltage: Designed For 100 V Line Systems. Rated Impedance: 833 Ohms. Connection: Shall Feature A 4-Pole Push-In Terminal Block On The Rear Panel For Easy On-Site Wiring And Power Tapping. Durability: The Unit Must Be Tested For 100 Hours Of Continuous Operation At Rated Power In Accordance With Iec 268-5 Standards. Mechanical Construction Enclosure Material: The Main Body Shall Be Constructed From Solid Mdf (Medium Density Fiberboard) Covered In Durable, Easy-To-Clean Black Vinyl. Front Grille: The Front Shall Be Abs Plastic Covered With A Fine Woven Cloth In Matching Black. Baffle Design: Shall Feature An Angled Front Baffle To Optimize Sound Distribution Within The Listening Area. Mounting: The Rear Panel Must Include Three Keyholes For Quick And Secure Wall Mounting. Dimensions: 445 Mm X 151 Mm X 150 Mm / 111 Mm Environmental Limits: Operating Temperature: -5 °C To +55 °C, Storage Temperature: -40 °C To +70 °C , Wireless Microphone System General System Requirements: Classification: The System Shall Be An Entry-Level Professional Wireless Microphone System Designed For Ruggedness And Ease Of Use In Daily Operations. Ease Of Setup: The System Must Include A One-Button Automatic Frequency Scanning Function To Identify The Clearest Available Channel. Transmitter Synchronization Shall Be Achieved Via An Infrared Data Link To Ensure Error-Free Setup. Frequency Management: The System Shall Provide 32 Preset Channels, With Compatible Groups Of Eight Channels For Simultaneous Multi-Channel Use. Operating Bands: The System Shall Be Available In Multiple Rf Frequency Bands, Including: A Band: 618-634 Mhz. B Band: 678-694 Mhz. C Band: 516-532 Mhz. E Band: 850-865 Mhz. Receiver Specifications Type: Synthesized Pll With True Antenna Diversity To Ensure Stable Rf Reception. Chassis: The Receiver Must Feature A True Rack-Mountable Metal Chassis Suitable For Professional Installation. Rf Performance: Sensitivity: 1.0 Μv For 12 Db Sinad. Image Rejection: Greater Than 55 Db. Audio Outputs: Balanced Output: 20 Dbv (Max @ 40 Khz Deviation). Unbalanced Output: Adjustable From 8 Mv To 0.755V Rms. Display: Front-Panel Backlit Lcd Displaying Channel, Frequency, And Battery Status. Handheld Transmitter Construction: The Transmitter Shall Feature A Rugged Metal Body Designed To Withstand The Rigors Of Daily Use. Microphone Capsule: Equipped With A Cardioid Dynamic Capsule (Pl22) For Effective Feedback Control And Ambient Noise Rejection. Battery Life: Must Operate For A Minimum Of 14 Hours Using Two Aa Alkaline Batteries. User Interface: Features A Backlit Lcd Display And A Dedicated Mute Function To Protect The Audio Channel. Bodypack Transmitter Construction: Compact And Rugged Metal Enclosure. Input Connector: Industry-Standard Ta4F Connector For Compatibility With Various Lapel Or Headworn Microphones. Antenna: Flexible External 1/4 Wave Antenna. Acoustic & Environmental Performance System Frequency Response: 80 Hz - 18 Khz ± 2 Db Signal-To-Noise Ratio: 100 Db A-Weighted Total Harmonic Distortion: 1.0%, 0.4% Typical (Ref 1 Khz, 40 Khz Deviation) , Professional Gooseneck Microphone General Requirements: The Microphone Shall Be A Professional-Grade, High-Quality Electret Condenser Gooseneck Microphone Designed For Public Address Applications Such As Lecterns, Podiums, And Open Conferences. It Must Feature A Sleek, Slender, And Unobtrusive Design To Maintain A Clear Line Of Sight For The User. Acoustic & Technical Performance Transducer Type: Electret Condenser. Polar Pattern: Unidirectional (Cardioid) To Ensure High Front-To-Back Rejection, Providing More Gain Before Feedback. Frequency Response: Wide Range From 20 Hz To 18,000 Hz. Sensitivity: 7.5Mv/Pa Power Requirement: Operable Via A Dc Power Source Ranging From 1.5V To 9V. Mechanical Specifications Overall Length: 585 Mm (Approximately 23 Inches) Output Connector: Built-In 3-Pin Xlr Male Socket For Secure And Standard Professional Connectivity. Optional Accessories (Compatibility) To Ensure System Flexibility, The Microphone Must Be Compatible With The Following Manufacturer-Specific Accessories: Microphone Base: A Sturdy, Heavy-Duty Die-Cast Aluminium Base With An Integrated On/Off Switch, Led Indicator, And Built-In Housing For 2 Times 1.5V Um-3 Aa Cells To Power The Condenser Element. Mic Stand Adaptor: A Rugged Aluminium Die-Cast Body With A Female Xlr Connector For Direct Mounting And A Male Xlr Bottom Connector For Cable Attachment. It Must Include A 10-Meter Shielded Cable And A Threaded Brass Ferrule 5/8 27 Tpi For Standard Stand Mounting. , Mixer Amplifier General System Requirements Type: The Unit Shall Be A Professional 120W Mixer Amplifier With Integrated Usb And Bluetooth Capabilities, Designed For Public Address And Background Music Applications. User Interface: The Amplifier Shall Feature A Simplified User Interface With Preferred Setting Indicators (Colored Pins) For All Front-Panel Knobs To Ensure Ease Of Operation For Non-Technical Users. It Must Include An Led Vu Meter For Visual Output Level Indication And A 6.3 Mm Headphone Socket For Monitoring The Mixer Output. Reliability: The Unit Shall Have No Moving Parts (Such As Hard Drives) To Ensure Long-Term Operational Reliability. Audio Inputs And Media Source Microphone/Line Inputs: Four (4) Balanced Inputs, Switchable Between Microphone And Line Level Sensitivity. Switchable Phantom Power Must Be Available To Support Condenser Microphones. Priority Handling: Input 1 Shall Have The Capability To Take Priority Over All Other Inputs Via Contact Closure (Push-To-Talk) And Include An Optional 2-Tone Chime To Precede Announcements. Music Source: Integrated Media Player: Must Support Playback Of Mp3 And Wav Files (From 32 Kbit/S) Via A Usb Pen Drive (Up To 32Gb Capacity). Wireless Streaming: Built-In Bluetooth For High-Quality Audio Streaming From Mobile Devices. Remote Control: The Unit Must Be Supplied With An Ir Remote Control For The Integrated Music Source. Aux Input: A Separate Stereo Cinch Input, Internally Converted To Mono, With A Sensitivity Of 200 Mv To 300 Mv. Audio Performance And Output Output Power: 120W Rated Output Power. Loudspeaker Outputs: Constant Voltage: 100 V. Low Impedance: 4-Ohm. Call-Only Output: A Dedicated 100 V Call-Only Channel For Priority-Only Areas Or 3-Wire Remote Volume Control Override. Frequency Response: 80 Hz To 18 Khz (+1/-3 Db At -10 Db Ref. Rated Output). Distortion: 1% At Rated Output Power (1 Khz). Tone Control: Dedicated Bass And Treble Controls Providing Max ± 8 Db Adjustment. System Protection: An Integrated Limiter Circuit Must Be Included To Protect The Output Stage From Signal Clipping And Overload. Insert Feature: A Pair Of Rca Cinch Connectors Shall Be Provided To Allow The Unit To Be Used As A Separate Pre-Amplifier And Power Amplifier. Mechanical And Environmental Dimensions: 100 Mm X 430 Mm X 290 Mm (Standard 19 Wide, 2U High). Mounting: Suitable For Both Stand-Alone Use And 19 Rack Mounting. Operating Temperature: -5 °C To +45 °C. Compliance: The Unit Shall Comply With Iec 62368-1 (Safety), Cispr 32 (Emc Emission), And En 55103-2 (Emc Immunity). , Mixing Console General Requirements The Mixing Console Shall Be A Compact, Versatile 6-Channel Analog Mixer Designed For A Wide Range Of Professional Audio Applications. It Must Feature High-Quality Microphone Preamplifiers And A Rugged Construction Suitable For Both Portable And Fixed Installations. Audio Inputs And Processing Input Channels: The Unit Shall Provide A Total Of 6 Line Inputs, Configured As 2 Mono And 2 Stereo Channels. Microphone Preamplifiers: The Console Shall Include 2 Microphone Inputs Featuring Discrete Class-A D-Pre Preamps With An Inverted Darlington Circuit For Superior Sound Quality. Switchable +48V Phantom Power Must Be Available For All Microphone Inputs. Channel Processing: Mono Inputs (Ch1-2) Shall Include A 26Db Pad For High-Level Sources. Each Mono Channel Shall Feature A High-Pass Filter (Hpf) Set At 80Hz With A 12Db/Octave Slope. Equalization For Mono Channels Shall Consist Of A 2-Band Eq: High (10Khz Shelving) And Low (100Hz Shelving) With Pm15 Db Adjustment. Output And Bus Section Buses: The Console Shall Feature 1 Stereo Bus. Outputs: Stereo Out: Provided Via 2 Xlr-3-32 And 2 Phone Jacks (Balanced). Headphones: One (1) Stereo Phone Jack Output With A Dedicated Level Control. Monitoring: Visual Monitoring Shall Be Provided By A 2 Times 7 Point Led Level Meter (Peak, +6, +3, 0, -3, -10, -20Db). Technical Performance Frequency Response: Pm 0.5Db From 20Hz To 20Khz (Referenced To Nominal Output Level @ 1Khz). Total Harmonic Distortion (Thd): 0.01% @ +8Dbu (20Hz To 20Khz), Gain Knob: Min 0.003% @ +18Dbu (1Khz), Gain Knob: Min Hum & Noise: Equivalent Input Noise Of -128 Dbu (Mono Input Channel, Rs: 150Ω, Gain Knob: Max) Crosstalk: -88Db @ 1Khz. Mechanical And Electrical Specifications Chassis: The Unit Shall Be Housed In A Robust, Impact-Resistant, Powder-Coated Metal Chassis. Power Supply: External Ac Adapter: Pa-130 (120V 60Hz) Or Mu18 (100-240V 50/60Hz) Or Equivalent. Power Consumption Shall Be Approximately 12W. , Indoor Wi-Fi6 Access Point General System Requirements Type: The Unit Shall Be A High-Performance, High-Speed 11Ax (Wi-Fi 6) Indoor Dual-Band Ceiling-Mounted Wireless Access Point (Ap). Standard Support: The Wireless Access Point (Ap) Shall Strictly Adhere To The Ieee 802.11Ax (Wi-Fi 6) Standard. Radio Configuration: The Unit Must Be A High-Power Industrial Ceiling-Mounted Ap Featuring 2X2 Mimo Technology For Both 2.4 Ghz And 5 Ghz Bands. Performance: The System Must Provide A Combined Wireless Data Rate Of Up To 3 Gbps To Support High-Speed Applications Such As 4K/8K Streaming And Vr/Ar. User Capacity: The System Shall Support A High Density Of Users, Accommodating Up To 128 Concurrent Users (Max 64 Users Per Band). Advanced Features: The Ap Shall Support Multi-User Mimo (Mu-Mimo), Orthogonal Frequency Division Multiple Access (Ofdma), Bss Color Bit, And Dynamic Cca-Sd For Improved Interference Management. Hardware Specifications Chipset: The Ap Shall Be Equipped With A High-Performance 4-Core Qualcomm Chipset. Ram: 512Mb Ddr3. Antenna: Integrated Internal 4X4Dbi Dual-Band Mimo Antennas. Combined Rate: A Concurrent Wireless Rate Of Up To 3000 Mbps. Physical Interfaces: 1 X 10/100/1000Mbps Wan/Poe Port. 1 X 10/100/1000Mbps Lan Port. 1 X Reset Button. Provision For A Dc2.0 12V 1.5A Power Connector. Support For Power Over Ethernet (Poe) Following Ieee 802.3Af/802.3At Standards. Thermal Management: The Unit Shall Feature A Heat Sink With A Snap-On Structure And Special Surface Coating To Optimize Heat Dissipation. Indicators: Led Status Lights For Power, Cloud Connection, Lan Speed, 2.4Ghz Status, And 5.0Ghz Status. Audio & Network Management Quality Of Service: Must Support Wmm (Wireless Multimedia Prioritization). Roaming: Support For Seamless Roaming To Ensure Uninterrupted Connectivity For Mobile Clients. Deployment: Flexible Deployment Options Including Standalone Mode, Mobile App Management, And Zero Touch Provisioning (Ztp). Network Management: Support For Vlan Settings, Cloud Access (In Gateway Mode), And System Logging. Management: Support For Remote Configuration And Management. Maintenance: Features For Backup/Restore Configuration, Factory Reset, Scheduled Reboots, And Lifetime Firmware Upgrades. Security Requirements Encryption: Must Support Wi-Fi Protected Access 3 (Wpa3) And Wired Equivalent Privacy (Wep) 64-Bit, 128-Bit, And 156-Bit. Access Control: Integrated Mac Address Filtering And Wireless Access Control To Identify Authorized Devices. Management Security: Secure Socket Layer (Ssl) For Remote Management Login And The Ability To Block Ssid Broadcasting. Environmental & Reliability Operating Limits: Working Temperature: -10°C To 55°C. Storage Temperature: -40°C To 70°C. Humidity: 5% To 95% Non-Condensing. Protection: Esd: Air ±8K, Touch 6K. Electrical Surge: Common Mode 2K, Differential Mode 1K. Power Efficiency: Maximum Power Consumption Shall Not Exceed 16 Watts. Oem Warranty And Support Local Presence: The Original Equipment Manufacturer (Oem) Must Have An Authorized Service Center Or Registered Office In Madhya Pradesh (Proof Of Gst/Msme/Registration Required With Bid). Warranty: A 2-Year On-Site Hardware Replacement Warranty Is Required, With New Hardware Provided Within 12 Hours Of A Call Lock (No Refurbished Or Repaired Products). Technical Support: On-Site Support Must Be Available Within 6 Hours Of A Request. Future Warranty & Support: Oem Must Have Warranty And Support Pack Purchase Option Before Expiry Of Warranty Period For Next Years. Service Availability: The Oem Must Provide A 24X7 1800-Series Toll-Free Number With Support Available In The Local Hindi Language. Product Life Cycle: The Quoted Product Must Have A Life Cycle Of No Less Than 5 Years From The Date Of Supply, Including Lifetime Free Firmware And Technical Assistance. Certifications: The Product Must Be Ce, Fcc, Rohs, Iec 15408 And Iso 9001. Certified. Bidder Must Have To Submit Compliance On Oem Letter Head Along With Maf. , Network Wall Mount Rack Must Have To Supply And Installation Of 15U 500X550 Network Wall Mount Rack With Glass Door And Lock With Hardware, 6 Socket Industrial Pdu 15Amp With Mcb, Cable Manager, Fan, Hardware And Etc. , Goosneck Mic Cable, Speaker Cable In Meter, Installation And Accessories Complete Job Work With Required Cables, Frpvc Conduit, Accessories, Fitting, Installation And Etc.
Contract Date: Jun 09, 2026 Contract Value : 2.02 Lakh
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
34.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
35.
Defence #11095455 AOC
Tender For Provision Of Stabilizer And Insolation Transformer On Hard (Rcc) Surface With Armored Cable At Tru At Af Stn Bkt; 1 Supply, Installation testing and commissioning of Isolation transformer, 3 Phase ,50HZ 125 KVA capacity ,copper wound, oil cooled, class A insulation, powder coated metallic body, designed for input voltage 415+ 5%,output voltage rate 415 + 5%,Ratio 1;1, DYN-11, Delta star indoor type, min IP 42 with first filling of transformer oil as per IS 335 upto level, efficiency more than 95%. separate neutral bush for neutral to earth less than IV, with all standard accessories including digital ammeter , voltmeter , short cicuit protection , unbalance voltage protection, MCCB/MCB of suitable rating in incoming with by pass arrangementdigital type temperatures meter, cooling radiator, lifting hook earthing terminals – 2 Nos with MCCB for overload / short circuit protection bushing complete all as specified and directed . The transformer shall be confirming to IS: 1180: 2014 and shall comprise of the following:- (a) Rating and diagram plate. (b) Two earthing terminals in two side. (c) Lifting lugs .(d) Off circuit link board. (e) Base channel with Bi- directional Rollers. (f) Danger board (g) 100 mm dial type thermometer. (h) Cable entry boxes etc complete as reqd. (i) Plinth of PCC (1:3:6) type C-1 using 20mm graded stone aggregate for placing and supporting of Isolation transformer complete all as specified and directed.Make:- Vinetec/ Servostar/ Volina/ Indian Transformer and Electrical (Note:- E-N voltage should not be more than 2 Volts). 2 Supply Installation testing and commissioning ofServo controlled voltage stabilizer of capacity 160 KVA Confirming to BIS 9815: Part1:1994 reaffirmed 2009) Three Phase, 50 Hz, Naturally Oil cooled, indoor, for unbalanced load, Copper wound, metallic body with lifting hooks, digital display type, relay free smooth and silent operation including 1st filling of transformer oil up to level having following specification:-(a) Input voltage 300V-480V, (b) Output voltage stabilized at any designed/ desired voltage 415(+/-)1%(c ) No distortion in wave form.(d) Respond time not to exceed 20 mili seconds (e) Sensitivity(+/-) 1% (f) 8 Volt/second correction . (g) Efficiency more than 98% (h) Type of load 3Phase, unbalanced type (i) Digital display Volt meter on incoming & outgoing to measure phase & line voltage with selector switch and Ammeter (j) Over load and short circuit protections , (k) High & Low voltage cut off(l) By pass arrangement in case of emergency and Single phase prevention complete all as specified and directed (m) MCCB of suitable rating at incoming and outgoing Make:- Vinetec/ Servostar/ Volina/ Indian/ Transformer and Electrical . 3 Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed. 4 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed . 5 Removing excavated materials (soil) not exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. 6 M & L for sand cushioning to underground cable with clean dry Ganga river sand complete all as specified and directed. Note:- Punned thickness only shall be measured & Paid. 7 M & L for precast cable cover class LV type 1 flat size 250mm x 150mm x40mm, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specified & directed. 8 Supplying, laying, connecting & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of size 185 sqmm 3.5 core complete all as specified and directed. Make - Polycab/Plaza/Havells/Finolex/ RR Cable. 9 Supplying, laying, connecting & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of size 120 sqmm 3.5 core complete all as specified and directed .Make - Polycab/Plaza/Havells/Finolex/RR Cable. 10 Supplying, laying, connecting & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of size 95 sqmm 3.5 core complete all as specified and directed. Make - Polycab/Plaza/Havells/Finolex/ RR Cable. 11 Supplying, laying, connecting & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of size 50 sqmm 3.5 core complete all as specified and directed. Make - Polycab/Plaza/Havells/Finolex/ RR Cable. 12 Supply installing testing and commissioning factory made and tested, CPRIapprovedLT main feeder pillar indoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 2mmCRCA mild steel sheet with 50mm x 50mm x6mm angleiron frame, hinged doors, front & rear opeing and lockingarrangement ( including provision of 65mm Godrej ( freedom) lock with 2 Keys) with necessary bus bar arrangment with insulated Aluminium bus barhaving current carrying capacity 1.5 times the rated current ratingfor phase & neutral, 4 strips 1.5 times of incoming rating on epoxy insulators, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCB with suitable capacity of Aluminium bus bar strips including heat shrinkable sleeves,and providing extended bus bars with chamber arrangement for outgoing cables, copper control wiringofrequired size forinstruments and comprising of the following including necessary PCC in (1:2:4) type B1 using 20mm graded stone aggregate for platform of suitable size Comple all as specified and directed.Make- Power system & Control , Prestige , Sparsh Engineering , REW INCOMING MCCB 250 Amp 36 KA 4 Pole, 50 HZ Thermal - Magnetic Release - 01 No 13 Supply installing testing and commissioning factory made and tested, CPRIapprovedLT main feeder pillar indoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 2mmCRCA mild steel sheet with 50mmx 50mmx6mm angleiron frame, hinged doors, front & rear opeing and lockingarrangement ( including provision of 65mm Godrej ( freedom) lock with 2 Keys) with necessary bus bar arrangment with insulated Aluminium bus barhaving current carrying capacity 1.5 times the rated current ratingfor phase & neutral, 4 strips 1.5 times of incoming rating on epoxy insulators, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCB with suitable capacity of Aluminium bus bar strips including heat shrinkable sleeves,and providing extended bus bars with chamber arrangement for outgoing cables, copper control wiringofrequired size forinstruments and and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size Comple all as specified and directed.Make- Power system & Control , Prestige , Sparsh Engineering , REW INCOMING MCCB 250 Amp 25 KA 4 Pole, 50 HZ Thermal - Magnetic Release - 01 No OUT GOING(i) MCCB 200 Amp 25 KA 4 PoleThermal - Magnetic Release-01 No. (ii) MCCB 125 Amp 16 KA 4 Pole Thermal - Magnetic Release-01 No.(iii) Digital Ammeter 0-100 Amp with built in selector switch - 01 No.(iv) Digital Voltmeter 0-500 Volt with built in selector switch - 01 No.(v) CT - 250/5 - 1 Set of three.(vi) Indicating lamp (RYB)-03 nos 14 Supply installing testing and commissioning factory made and tested, CPRIapprovedLT main feeder pillar Outdoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 3.15 mmCRCA mild steel sheet with 50x 50x6mm angleiron frame, hinged doors, front & rear opeing and lockingarrangement ( including provision of 65mm Godrej ( freedom) lock with 2 Keys) with necessary bus bar arrangment with insulated Aluminium bus bar having current carrying capacity 1.5 times the rated current ratingrating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCB with suitable capacity of Aluminium bus bar strips including heat shrinkable sleeves,and providing extended bus bars with chamber arrangement for outgoing cables, copper control wiringofrequired size forinstruments and and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size:- Make- Power system & Control , Prestige , Sparsh Engineering , REWINCOMING MCCB 200 Amp 25 KA 4 Pole, 50 HZ Thermal - Magnetic Release - 01 No OUT GOING(i) MCCB 200 Amp 25 KA 4 PoleThermal - Magnetic Release-02 No. (ii) MCCB 63 Amp 25 KA 4 Pole Thermal - Magnetic Release-01 No.(iii) Digital Ammeter 0-100 Amp with built in selector switch - 01 No.(iv) Digital Voltmeter 0-500 Volt with built in selector switch - 01 No.(v) CT - 200/5 - 1 Set of three.(vi) Indicating lamp (RYB)-03 nos 15 Supply installing testing and commissioning factory made and tested, CPRIapprovedLT main feeder pillar Outdoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-54 class protection and made of 3.15 mmCRCA mild steel sheet with 50x 50x6mm angleiron frame, hinged doors, front & rear opeing and lockingarrangement ( including provision of 65mm Godrej ( freedom) lock with 2 Keys) with necessary bus bar arrangment with insulated Aluminium bus bar having current carrying capacity 1.5 times the rated current ratingrating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCB with suitable capacity of Aluminium bus bar strips including heat shrinkable sleeves,and providing extended bus bars with chamber arrangement for outgoing cables, copper control wiringofrequired size forinstruments and and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size Comple all as specified and directed. Make- Power system & Control , Prestige , Sparsh Engineering , REWINCOMING MCCB 200 Amp 25 KA 4 Pole, 50 HZ Thermal - Magnetic Release - 01 No OUT GOING(i) MCCB 125 Amp 25 KA 4 PoleThermal - Magnetic Release-01 No. (ii) MCCB 63 Amp 25 KA 4 Pole Thermal - Magnetic Release-01 No.(iii) Digital Ammeter 0-100 Amp with built in selector switch - 01 No.(iv) Digital Voltmeter 0-500 Volt with built in selector switch - 01 No.(v) CT - 200/5 - 1 Set of three.(vi) Indicating lamp (RYB)-03 nos(vii) Tempra plug 125 A 3P+E - 01 No.(viii) Tempra plug 63 A 3P+E - 01 No. 16 Supply and fix or laying in trenches GItubing light grade of road crossing for cable protection etc,of the 80mm dia sizes including necessaryrequired complete all as specified and directed by Engr-in-charge.Make - Jindal / Prince Pipe/ Prakash Surya. 17 M& L for Earthing complete with copper plate earth plate electrode 60mm x 60mm x 3.15 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to copper strip of size 20mm x 3 mm as earth leadby means of bolts, nuts, check nuts and washers of brass or steel all as shown in electrical plate No 3 of MES Schedule Part-Iincluding and connecting to earthing testpoint block made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 25 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC base 1:4:8 type using 40 mm agregrate of size 750x750x100 mm thick with precast RCCcover 40 mm thick in PCC (1:2:4) type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia welded with steel plate including painting with applying one coat of red oxide and two coat ofpainting with synthetic enameled paint of approved qualityincluding writting letters as specified including testing on completion complete all as specified and directed. 18 M& L for Earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) withtop edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 25mm x 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete all as shown in electrical plate No 3 of MES Schedule Part-Iincluding and connecting to earthing testpoint block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 40 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) and (1:4:8) type D2 using 40 mm agregrate of size 750mm x 750mm x 100 mm thick with precast RCCcover 40 mm thick in PCC (1:2:4) type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat ofpainting with synthetic enameled paint of approved qualityincluding writing letters as specified including testing on completion complete all as specified and directed. 19 S&F Submain wiring with two single core PVCinsulated FRLS multistrand copper conductor cable of size 10Sq mmdrawn into and including non metallic heavy duty rigid concealedPVCconduit not less than 25mm size ISI marked ivory colour (Pressfit or similar brand ) with allfittings / accessories and 10Sq mm FRLS multistrand copper conductorcable as continuous earth wire complete all as specified and directed.Make- Polycab/Havells/RR kables/plaza (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesare deemed to be included in the unit rate quoted for this items.) 20 S&F Submain wiring with two single core PVCinsulated FRLS multistrand copper conductor cable of size 16Sq mmdrawn into and including non metallic heavy duty rigid concealedPVCconduit not less than 25mm size ISI marked ivory colour (Pressfit or similar brand ) with allfittings / accessories and 16Sqmm FRLS multistrand copper conductorcable as continuous earth wire complete all as specified and directed.Make- Polycab/Havells/RR kables/plaza (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesare deemed to be included in the unit rate quoted for this items). 21 S&F Sheet metal enclosure 4 way double door distribution board when MCB to be used TPN 4 way ,415 volt complete all as specified and directed.Make - Seimens/Havells/Legrand/ L&T/ C&S. 22 S&FMCB TPN 63-100Amps 415 volt rupturing cap 10 ka C series complete all as specified and directed.Make - Seimens/Havells/Legrand/ L&T/ C&S. 23 S&F MCBsingle pole, 6 to 32Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified and directed. Make - Seimens/Havells/Legrand /L&T/C&S. 24 Supply , installation, testing and commissioning of wall mounted hi wall split inverter type air conditionerunits of capacity 2 TRindoor unit ,outdoor unit complete with cordless remote control unit and with filter for better indoor air quality with minimum 5 star rating for operation on 230V , 50 Hz , single phase AC supply , complete interconnecting copper refrigerant piping , electrical cabling , drain piping , wall sleeve, supporting brackets for outdoor unit , and all necessary fittings , supports , fasteners etc as required complete all as specified and directed. Make - Daikin / Hitachi / O General / LLoyd. 25 S&F electronic wall mounted digital display(Input & output) voltage stabilizerfor automatic voltage correctionsingle phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230Volt and High / low voltage cut off with facility of including instant start & time delay relay of 10 second of capacity4KVA complete all as specified and directed. Make-V guard/Volina/ Blue bird. 26 S&F Submain wiring with two single core PVCinsulated FRLS-H multistrand copper conductor cable of size 04 Sq mmdrawn into and including non metallic medium duty rigid concealedPVCconduit not less than 25mm size ISI markedwith allfittings / accessories and 04 Sq mm FRLS-H multistrand copper conductorcable as continuous earth wire complete all as specified and directed. Make- Polycab/Havells/RR kables/plaza (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesare deemed to be included in the unit rate quoted for this items.) 27 S&F socket outlet 5 pin 20 amp modular type 2 module with suitable size of module metal flux boxes and including modular front cover plate and back plate for mounting modular type switch & socket with one single poleone module MCB of 20 amp including electrical connection all as specified and directed by Engineer-in-Charge. Make - Havells / ABB/ Goldmedal / Legrand/ L&T. 28 M&L forflame proof pointwiringwith two single core FRLS-H PVC insulated& PVC unsheathed multi stranded copper conductor cable of size 1.5Sqmm1100 voltsgradein and includingstove enamelled steel conduit of size20 to 25 mmwith all accessories and one single core PVC insulated & PVC sheathed multistranded FRLS-H copper cable of size 1.5 Sqmm 1100 Voltsgradeas earthcontinuityconductorconnectedto commonearth dolly, switch board complete incuding cutting chesses on wall/ floour/ ceiling etc. & making good the disturbed surface with (1:4) cement morter all as specified for one light / fan point controlled by one 5 Amps flameproofswitch one way complete all as specified and directed. 29 S&F switch flame proof rotory type with termination box in LM 6, 16 A,single phase 250 volts,complete all as specified and directed. 30 S&FLED Light Fitting 2x20 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &III B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable with suitable sizecomplete all as specified and directed. 31 S&F flame proof metallic body exhaust fan single phase 230 Volt 50 Hz 300 mm 1440 RPM with louvers and shutter including civil work i.e making of holes and complete with all fixing accessories all as specified and directed. 32 M & L for point wiring with two single core PVC insulated & PVC unsheathed FRLS-H multistranded copper conductor cable of size 1.5 sqmm 1100 volt gradedwawn into and including non metallic rigid PVC concelled conduit medium grade 25 mm dia with all accessories mounting all the surface of wall/ceiling/roof/etc with suitable size of module metal flush boxes and including modular front coverplate & back plate for mounting modular type switches /socket/fan/ regulator etcincluding provision of one single corePVC insulated and unsheathed multi stranded copper cable of size 1.5 sqmm 1100 volt grade as earth continuty conductor connected to common earth dollyswitch board complete all as specified and directed for following-Make of Cable -Polycab/Plaza/Finolex/Havells.One light/fan point controlled by one switch SP 5 Amps ,240 V 33 Ditto all as per item No 32 here-in-before One bell/buzzer point controlled by bell push complete all as specified and directed. 34 Ditto all as per item No 32 here-in-before One 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed. 35 Ditto all as per item No 32 here-in-before One 3 pin 5 amps socket point on same board complete all as specified and directed. 36 Ditto all as per the item no 32 herein before but with 2.5 sqmm conductor for5 pin 15 Amps switch socket outlet complete all as specified and directed. 37 S&F switch modular type 1 module single pole, one way 5 Amps complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB/ L&T. 38 S&F switch modular type 1 module single pole, one way 15 Amps complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB / L&T. 39 S&Fsocket outlet 2 in 1, 5 pin, 15Amps modular type 2 module complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB /L&T. 40 S&F socket outlet 5Amps modular type 2 module complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB / L&T. 41 S&F modular Bell push 5 Amps complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB /L&T. 42 M&L for ceiling rose,PVC/polycarbonate, isolated body complete all as specified and directed. 43 S&F stepped type electronic fan regulator modular type 1 module complete all as specified and directed.Make:- Havells ( Crabtree )/Goldmedal/ABB or equivalent 44 S&F bell, ding dong type AC, 230 Volt, single pole. complete all as specified and directed. 45 S&F LED batten light fittings 18/20 watt ,220 volt AC, connecting up with 3 core flexible cable copper conductor of suitable size from ceiling rose complete all as specified and directed. .Make:- Havells/Phillips/Bajaj L&T 46 Horizontal boring in soft/loose soil/under roads of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables complete all as specified and directed. Note : GI pipe shall be measured and paid separately under relevant items given here-in-after. 47 M&L for copper strip of size 20 mm x 3 mm complete with saddles , insulators and fixing screws for fitting the strip for earth continuty conductor up to test points and up to Electrical equipments complete all as specified and directed . 48 M&L for GI strip of size 25 mm x 4 mm complete with saddles , insulators and fixing screws for fitting the strip for earth continuty conductor up to test points and up to Electrical equipments complete all as specified and directed . 49 Supply and layinggalvanised iron tubing, 40 mm bore,light grade protection of earth strip pipe with all fittings forfixed to pole/wall/ in ground including all fixing accessories completeall as specified and as directed.Make- Jindal/TATA / Prakash Surya.
Contract Date: Jan 01, 2026 Contract Value : 23.91 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
36.
Drinking Water Supply and Sanitation #11087677 Price Bid
Tender for E-Quotation For Seeking Firm Rates Of Plant & Machinery And Materials Category Items For Preperation/Amendment Of Schedule Of Rate For The Year 2026. , M 1055 - Pumps Supplying Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene/ Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon/ Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single/ Double Run Shall Be Provided With Each Pump. , Submersible Pump Set 100 Mm Dia (With Polypropylene/ Noryl Impeller) Up To 20 Stages 1 H.P. , 1.5 Hp , 2.5 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , Submersible Pump 150 Mm Dia (With Bronze/Ss Impeller) Up To 8 Stages , 1.5 Hp , 2.0 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , 6.0 Hp , 7.5 Hp , M 1056 - Pressure Guage Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint , Pressure Gauge (100 Mm Dia) , Pressure Gauge (150 Mm Dia) , Vacuum / Combination Gauge , M 1057 - Lifting Equipment Chain Pulley Block Supplying Triple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. , 1 Tonne Capacity , 2 Tonne Capacity , 3 Tonne Capacity , Electric Operated Circular Or Rectangular Travelling Crane (Single Girder) Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. , 5 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , 7.5 Tonne Capacity , Above 6 M Upto 8 M Span , Above 8 M Up To 10 M Span , 10 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , M 1058 - Lightening Arrester, Ab Switch, Insulators , Lightening Arrestor Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. , Suitable For 11 Kv Supply, Distribution Class , Suitable For 22 Kv Supply, Distribution Class , Suitable For 33 Kv Supply, Station Class , Disc Insulator. Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Pin Insulator Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Air Break Switch Without Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11Kv Line , Rocking / Tilting Type , Rotating Type , Suitable For 33Kv Line , Rocking / Tilting Type , Rotating Type , Air Break Switch With Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11 Kv Line , Rotating Type , Suitable For 33 Kv Line , Rotating Type , Drop Out Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , Horn Gap Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , M 1059 - Transformer Power Transformer (With Off Load Tap Changer) Any Isi Mark , Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issed By Seb Which Ever Are Lower- 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. , Power Transformer 11000/433 Volts With Off Load Tap Changer - 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. , 63 Kva , 100 Kva , 160 Kva , 200 Kva , 250 Kva , 315 Kva , 500 Kva , 630 Kva , 750/800 Kva , Power Transformer (With On Load Tap Changer) Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- , 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. 12. Buchholz Relay 13. Resistance Temp. Detector 14. Marshalling Box 15. Automatic Voltage Regulator (Avr) 16. Remote Tap Changing Controller (Rtcc) , Transformer 11000/433 Volts With On Load Tap Changer - 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification , 750/800 Kva , 1000 Kva , 1250 Kva , 1600 Kva , 2000 Kva , M 1060 - Motors Foot Mounted Motors Tefc 1500 Rpm Supplying Foot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts ± 10%, 3 Phase, 50 Hz ± 3% With F Class Insulation Temperature Rise Limited To Class B Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. , 15 Kw (20 Hp) , 18.5 Kw ( 25 Hp) , 22 Kw ( 30 Hp) , 30 Kw ( 40 Hp) , 37 Kw ( 50 Hp) , 45 Kw ( 60 Hp) , 55 Kw ( 75 Hp) , 75 Kw ( 100 Hp) , 90 Kw ( 120 Hp) , 110 Kw ( 150 Hp) , 132 Kw ( 180Hp ) , 160 Kw ( 215 Hp ) , M 1061 - Aluminium Cable Cable - Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150 Sq Mm , 3 Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated Supplying Ht Aluminium Three Core Cable Xlpe Insulated ,Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape (0.3 Ka For 1 Sec.) Cores Laidup Inner Sheath Of Pvc Tape ,Galvanised Steel Flat Strip Armoured,And Overall Pvc Sheathed Cable Conforming To Is :7098 /Ii/85 With Latest Amendments , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core150sq Mm , 3 Core 185 Sq Mm , 3 Core 240Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1062 - Copper Cable Cable , 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3 .5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3 .5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor 3.5 Core Xlpe/Pvc Unarmoured Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3.5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3.5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150Sq Mm , 3Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1063 - Foot Valve Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. , Flanged Type , 50 Mm , 65 Mm , 80 Mm , 100 Mm , 125 Mm , 150 Mm , M 1064 - Air Circuit Breaker Acb Breaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole , 1000A , 1250A , 1600A , 2000A , M 1065 - Starter D.O.L. Starter With Ss Enclosure With 380/415 Volt Coil , 5 To 10 Hp , Supplying Fully Automatic Star Delta Starter To Operate Induction Motor Working On 415V,3Phase,50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser F.A.S.D Starter , 10 Hp , 20 Hp , 25 Hp , 40 Hp , 50 Hp , 75 Hp , 100 Hp , 125 Hp , 150 Hp , 250 Hp , M 1066 - Servo Controlled Automatic Voltage Stabilizer Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt ± 1%, 3 Ph, 50 Hz, With Copper Wound Transformer (Air/Oil Cooled) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And Users Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto/Manual Selector Switch, Raise/Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated 􀂌 Over Voltage / Under Voltage 􀂌 Single Phasing 􀂌 Cut Off Contactor With Electronic Output Sensing Unit , Servo Controlled Automatic Voltage Stabiliser(Out Put 415 ± 1%) Input 150 / 220 To 450 / 460 Volt , 30 Kva Air Cooled , 40 Kva Air Cooled , 50 Kva Oil Cooled , 60 Kva Oil Cooled , 75 Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , Servo Controlled Automatic Voltage Stabiliser (Out Put 415 ± 1%) Input 280 To 450/460 Volt , 15 Kva Air Cooled , 20 Kva Air Cooled , 30 Kva Air Cooled , 40 Kva Air Cooled , 50Kva Air Cooled , 60 Kva Oil Cooled , 75Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , 150 Kva Oil Cooled , 200Kva Oil Cooled , M 1067 - Termination Kit Providing And Errecting In-Door Type Termination Kit, For 3.3Kv/ 6.6 Kv / 11Kv/ 22Kv/33Kv Xlpe Screened 3 Core Cable , In-Door Termination Kit For 3.3Kv(E/Ue) / 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out-Door Termination Kit For 3.3(E/Ue)/6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 3.3Kv(E/Ue)/ 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 11 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 22 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-150 Mm² , 185-240 Mm² , 300-400 Mm² , In Door Termination Kit For 33Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 33 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Straight Through Joint For 33 Kv(E) Xlpe Screened 3 Core Cable , 35-70 Mm² , 95-150 Mm² , 185-240 Mm² , 240-300 Mm²
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
37.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
38.
Agriculture #10988522 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In, All Kinds Of Soil , Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.M20 Grade Nominal Mix / Design Mix , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Columns, Pillars, Posts And Struts Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786)Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Brick Work With Clay Flyash F.P.S. Brick (Is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And Two Corners Are Free , Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , P & F 1St Qualityheavy Duty Vitrified Polished Digital Tiles On Floor, Skirting And Steps Etc.In Different Sizes (Thickness Minimum 10Mm) With Water Absortion Less Than Or Equal 0.08% And Conforming To Is 15622 Of Approved Make In All Colour And Shade, Laid With 20 Mm Thick Cm 1: 4 Including Grounting The Joints With White Cement And Matching Pigment Etc Complete.Size 600Mm X 600Mm , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Extra For Using Size Above 200X300mm In Glazed Tiles And For Using 400Mm X 400Mm Mat Finished Tiles In Place Of 300Mm X 300Mm Size. Wall Tiles , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Chargeprofile C : , Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). , Providing And Fixing M.S. Sheet 1Mm Thick Single Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge , (A) Window Openable. , (B) Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dark Shade Using Ordinary Cement. , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :12Mm Thick . , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 20Mm Thick . , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Fixed Portion Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Is : 6315 Marked, For Doors Including Cost Of Cutting Floors As Required, Embedding In Floors And Cover Plates With Brass Pivot And Single Piece M.S. With Stainless Steel Cover Plate , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge.(Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.)With Float Glass Panes Of 5.0 Mm Thickness ( Weight Not Less Than 13.50 Kg/Sqm) , Providing And Fixing Expanded Grill Made Of Aluminum As Per Design And Drawing Having Members Section Of Size 7.5Mm X 6.0Mm And Opening Of Size 102Mm X 99Mm To Aluminum Window/Vent With Required Screws, Y And H Aluminium Sec (As Per Drawing) At The Ends And Middle Joints Respectively Complete In All Respect As Per Direction Of Engineer In Charge.Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , Providing And Fixing Curtain Rods Of 1.25 Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs, Etc., Wherever Necessary Complete: 20 Mm , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. , Carriage Of Earth Incloding Loading ,Unloading Without Stacking With Lea Of 5Km , Making Grooves As Per Design In Plaster 10Mm To 20Mm Wide. , Extra For Plastering Done On Moulding Cornices Or Architraves Including Neat Finish To Line And Level: In Two Coats , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated ‘J Or ‘L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified.5.0Mm Thick (Wt. 8.4 Kg./Mtr. Sq.) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Crazy Marble Stone Flooring 20Mm Thick Marble Stone With Black Or Of Specified Colour Topping Including Filling The Gaps With Cement Marble Chips Mix In Proportion Of 4 : 7 (4Cement : 7 White Black Or White Or Black Marble Chips) Size From 1Mm To 4Mm By Volume And Under Layer Of 25Mm Thick Cement Concrete [1:2:4, Graded Stone Aggregate 12.5Mm Nominal Size] Rubbing And Polishing And Cement Slurry Etc. Complete : In Ordinary Cement. , Extra In Marble/Other Flooring Work For Upto 50 Mm Wide Strip Of Green/White/ Jaisalmer Stone In Flooring Work As Per Direction Of Engineer In Charge , Providing & Fixing Precast Cement Concrete Coping 1 : 2 : 4 Mix 50Mm Thick Complete As Per Specification : , Renewing Glass Panes,With Putty And Nails Wherever Necessary Float Glass Panes Of Thickness 5 Mm , Filling Of Sunk Portion Of Roof With Earthen Pots Of Required Height Including Filling Voids With 1:3:6 Light Concrete, Using Brick Bats Complete Levelling And Dressing The Surface By 50Mm Thick Cement Concrete 1:2:4 As Per Specification. , Supply And Fixing In Cement Mortar Welded Hand Railing Made Out Of Ms Round Or Square Bars, Flats Etc. For Staircase Or Verandah As Per Design Complete In All Respect (Wooden Or Pvc Hand Railing To Be Paid Extra) With Priming Coat Of Red Oxide. , Extra For Providing D Type Pipe Head As Top Of Hand Railing , Providing And Fixing Almirah Lock (50 To 70 Mm Size )Of Approved Make Without Pair Of Handles For Door With Necessary Screws Etc Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Grade 304 , Lettering With Black Japan Paint Of Approved Brand And Manufacture. , Construction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layers With Tractor Mount Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Smooth Wheel Roller To Achieve The Desired Density, Complete As Per Morth Specification Clause 401..For Grading Iii Material , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 5.00Km As Per Morth Specification Clause 305.3 , Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mixer (Pug Mill), Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers In Sub-Base/Base Course On A Well Prepared Sub-Base And Compacting With Smooth Wheel Roller Of 80 To 100Kn Weight To Achieve The Desired Density Including Lighting, Barricading And Maintenance Of Diversion, Etc As Per Tables 400-12 & 400-13 And Morth Specification Clause 406.By Mechanical Means With All Lead , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 80 Mm As Per Drawings And As Per Is 15658:2006.And All Materials Shall Conform To Morth Specification Clause 602.With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blockscategory B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Dia. Nominal Bore. , Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 200Mm Dia. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. 200Mm Normianl Bore , Supply Of Erw M.S. Black Casing Pipe Isi Marked Is:4270/ 1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 200Mm Normianl Bore , Development Of Tube Well As Per Is Specification Using Suitable Compressor To Give Sand Free Water For Required Yield Of The Gravel Packed Tube Well. , S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size:200Mm Dia. , S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete :Solid Pvc (Is 2548 Marked) Grade-I Black For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend And Superior Internal Fittings As Per Is : 7231 . , P & F Flush Pipe Of Approved Make With Complete Fittings For High Level Flushing Cistern: Pvc Exposed (Heavy) 32Mm. , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : , Size 580 Mm X 450 Mm , Size 630 Mm X 500 Mm Dia For Counter Top , P & F Bevelled Edge Mirror/Mirror With Teak Wood Lipping Around Of Special Glass Of Approved Make As Per Direction Of Engineer-In-Charge Complete With 6Mm Thick Commercial Ply Base Fixed To Wooden Screws & Washers. Size 600 X 450Mm X 4 Mm Thick , P & F Towel Rail Or Ring Of Approved Quality/Make: , C.P. Brass Towel Rail Elbow Type With Concealed Screws Size 450Mm (Heavy Duty). , P & F Grating Of Approved Quality/Make: , Stainless Steel Sheet Size 125Mm Dia. , P & F Liquid Soap Container With Brackets Complete Of Approved Make: , P & F Jet Spray For Water Closet With C.P. Copper Tube Flange Of Approved Make. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Making Connection Of G.I. Distribution Branch With G.I. Main Including All Fitting. , Upto 25Mm Dia , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: , C.P. Brass Bib Cock,15Mm Nominal Bore. , C.P. Brass Bib Cock Long Body, 15Mm Nominal Bore Weight Not Less Than 690 Gm , P & F Ball Cock (Is :1703 Mark) With Rod & P.V.C. Ball Complete : Brass Wt. Not Less Than 300 Gm,15Mm. , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make : Pvc Pipe With C.P. Brass Nuts Upto Length 450Mm. , P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make : , Gun-Metal 15Mm Nominal Bore. , Gun-Metal 25Mm Nominal Bore. , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 1000 Litres Capacity , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia , P & F S.W. Master Trap (Inter-Cepting) A Grade (I.S.: 651 Marked) Of Approved Quality/Make 150Mm Dia , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: 110Mm Dia , Coupler (Socket) , Plain Tee , Bend 45 , Vent Cowel , Pipe Clip , Multi Floor Trap , Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade cement concrete Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead. Depth Up To 0.5 M , Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick cement concrete 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr. -Do- Size 600 X 450Mm Depth Upto 0.5 M Cement Cover With Frame. , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Construction Of Recharge Shaft In Filter Pit Including Earth Work Excavation , Lifting Excavted Earth With All Lift And 50 M Lead And Centering & Shuttering Evenever Required.Diameter 900 Mm , Supply & Fixing Pre-Cast Reinforced Cement Concrete Rinngs At The Mouth Of Recharge Shaft Of M20 Mix With 40 Mm Thicknessdiameter 900 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In All Kinds Of Soil , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :20Mm Thick . , Finishing With Neat Cement (Punning). , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix. , Add Extra For Providing Richer Mixes Respectively At All Floor Levels, Providing M-25 Grade Concrete By Using Min 410 Kg Of Cement Per Cum Instead Of M-20 Grade Design Mix. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting (Height Upto 10 M) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , Inside Size 600X450mm Upto Depth Of 0.5M & 38Kg Ci Cover With Frame , 250Mm Dia Internal. , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii(4 Kg. /Cm.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant, 160Mm Dia. , 250Mm Dia S.W. Pipe. , P & F 60 Cm. Wide M.S. Ladder In Open Well Made Of Flat Iron 32X5mm And 10Mm Dia Bars @ 200Mm C/C With Angle Iron Hold Fasts At Suitable Interval Complete As Per Drawing. , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Nominal Bore , P & F G.I. Pipes (Internal Work) With G.I. Fittings (Is:1239-1992 Mark) & M.S. Clamps Including Cutting And Making Good The Walls And Floors : Exposed On Wall, 15 Mm Dia Nominal Bore. B - Class. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. , Size 9 To 12 Mm , Size 3 To 5 Mm , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of Twin Control Light Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 2 Nos Hot Dipped Galvanized M.S Modular Box Of 1.2 Mm Thick With Earth Terminal,2 Nos10 A Two Way Modular Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector ,Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr..) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , On Board , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , S&F Following Sizes (Dia.) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Mm , 32 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 2X 1.5 Sq.Mm , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , 4 X 10.0 Sq.Mm , 4 X 16.0 Sq.Mm , Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Providing & Fixing Of Wiring Accessories Oem Fabricated Following Size Gi Box Of 1.2 Mm Thick With Earthing Terminal And Adjustable Floating Clamp In Recess/ Surface Suitable For Modular Accessories As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1/2 Module , Providing & Fixing Of Following Size Mounting Grid Plates With Cover Plates Made From Fire Retardent Uv Established High Performance Engineering Plastic Suitable For All Universal Metal Boxes For Front Installation & Removal Direct Fit Type Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1-2 Module , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Single Pole Mcb (With B/C Curve Tripping Characteristics) , 6 A To 32 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box , 6 Way , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For Mcb / Rccb And Sp / Tp Mcb As Outgoing ,Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door (For Double Door Db Only ) Complete With Insulated 100 A Rating Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Double Door Ik-09 & Ip-43 With Metal End Box , 6 Way(8+18) , Providing & Fixing Of 240/415 V Isolator Isi Marked Is:13947-Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Four Pole Isolator , 80 A/ 100 A Rating , Triple Pole Isolator , 63A Rating , Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Amp. 2 Module Motor Starter With On / Off Push Button , Blanking Plate , Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 5 Step Fan Regulator 2 Module 360 Dgree Rotating , Providing & Fixing Of Modular Type Switch/ Bell Push Duly Isi Marked (Is :3854) With Cm/L No. Printed And Made Out Of Unbreakable And Fire Retardant Vergin Uv Stabilized Polycarbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating ,Minimum Width Of Switch Toggle( Push Part ) Should Not Less Then 20Mm, Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 10 A Bell Push , Providing & Fixing Of Ding Dong/Musical Chime Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply Installation Testing and Commissioning of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Improvement =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , 3 Pole Mccb With Thermal Magnetic Release , Up To 100 annual periodical maintenance , 25 Ka, Adjustable O/L & Adjustable S/C Setting, , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 35.0 Sq. Mm , 3.5 Core , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Supplying And Making End Termination With Heavy Aluminium Lugs ( Pin / Ring Type ) Confirming To Is 8309 -1993 & Is 8337-1976 Duly Crimped With Crimping Tool, Pvc Tape Etc Of Following Size.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 35.0 Sq.Mm , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 50 Mm , Labour Charges For Excavating Trenches Of Required Width For Pipes Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr.: , All Kind Of Soils , Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor ,Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 300 Mm Sweep , P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Reqd. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Up To 380 Mm Size , Providing & Fixing Of Energy Efficient Direct Fit (Retrofit) Polycarbonate/ Glass Housing Smd Mid Power Led Tube Rod (With Integral Driver & Alumn. Heat Sink ), On Existing Fixture. System Lumen Efficacy ≥ 100 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv ,Thd 20% ,P.F.≥0.95,Cri 80 , Life Time Of Minimum 35000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80)Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200Mm , Min. Lumens Output 2000 Lm Led Tube Rod With Polycarbonate Housing , Providing & Fixing Of Ip20, 2X2 Led Surface/ Recessed Mounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/External Surge Protection Bis Certified Isolated Driver Having Efficiency 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 10 % , P.F.≥0.95,Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Moutning , Minimum Lumen Output 3600 Lm , Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Mounting (With Extruded Alumn. Housing ) , Minimum Lumen Output 1300 Lm , Minimum Lumen Output 1950 Lm , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached. , 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Led Street Light Fixture With Minimum Lumen Output 12500 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 32 Mm Dia. , Supply Installation Testing and Commissioning of Mnre Approved & Confirming To Is:12933 P-1,2,3 & 5 Flat Plate Collector Type Solar Hot Water System Having Collector With Zincalum Sheet Outer Body , Glass - Line / Titanium Enamel Coated Inner Tank With Metal Rust Proof Puf Insulated Body Including Electrical Back Up, Thermostat, Powder Coated / Hot Dipped Galvanized Ms Stand For Collector & Tank Etc. As Required. Of Following Capacity Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 250 Litre/ Day , Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 4 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1.5 Tr Iseer Not Less Then 3.8 , Supply Installation Testing and Commissioning of Monoblock Motor Pump Set Isi Marked (Is:9079-2002) With Tefc Motor, Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011. With Stainless Steel Impellor, Stainless Steel Shaft, Mechanical Seal, Single/Three Phase ( 240 - 440 V ) Permanent Split Capacitor Type (Psc), Fitted With Thermal Overload Protection, Including Cost Of Hardware Etc On Existing Platform Complete. Pump Shall Have Following Hp Rating, Phase, Head, Minimum Discharge Respectively Complete In All Respect. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 2.0 Hp, 3-Ø, (6-27)Mtr, (425-100) Lpm , Supply Installation Testing and Commissioning of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , For Single Phase Submersible / Monoblock Pump , 2.0 Hp To 3.0 Hp (Dol Starter)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
39.
Power #10977330 Price Bid
Upgradation of EOT crane 65 Ton installed at Gate chamber of BHEP-I- 1 SITC of one no. Main Hoisting Motor (specifications TYPE OF MOTOR- SQ. CAGE(D/E), FRAMING SIZE -VD 250M, KW RATING-28.70, NO. OF POLES OF MOTOR-6,START/HOUR-150, RPM OF MOTOR-975, make ALSTOM/BBL or equivalent), Replacement of one no. EHTBrake of Main Hoist( specifications THRUSTER CAPACITY in kgs-18, TORQUE RATING 42.00 kg-m, DRUM DIA- 300 mm, MAKE SOC or equivalent),Replacement of one no. DCEM(DISC) Brake of Main Hoist( specificationsTORQUE RATING 45.87 kg-m, DRUM DIA- FDB-30 mm, MAKE EMCO or equivalent). 2 SITC of limit switches(make ELECTROMAG/SOC/MAGCO or equivalent) 10amp with complete control panel circuit , power supply copper coated cable 415v-3 phase ,93 sqmm, control supply wire 110vac with olr circuit breakers, repair ofcabin room for D/G EOT crane , replacement of DSL Bus bar system and bridge control panel towing arm and other allied equipments and with supporting iron channelClamp and power supply.Thejob also including 04no. 400wattage of halogen high beam light and 04no. of 250wattage of flood light with control light and all electrical equipments & wiring replacement of EOT crane. (providing & fitting of New control Panel)Make of panel inclusions -Schneider, ABB, Rita. Cable make : Havels, Polycab 3 Providing and fitting of wire Rope as per installedDia- 22mm,construction- 6x36, type- fibre core quality-1960N/mm2, galvanized , breaking strength-313kn make –usha martin or equivalent, height of lift 27.0mtr&length of each rope drumis 4850mm, length of wire rope 380m, providing and fitting of HOOK along with safety hook(make RAMSHORN or equivalent ) as per sample available at site 4 SITC ofmicro motor (5.5kw/945rpm type sq, cage ,frame size- D 132M,no. of poles of motor-6, start/hour-150) 5 SITC of one no. micro brake type EHT (drum dia-250mm, torque rating-18kg-m, thruster capacity-18 kgs) SITC of one no. micro brake type ACEM(drum dia-180mm, torque rating-10.20kg-m, make- BCH or equivalent) 6 SITC of micro motor 0.7kw/840rpm type sq. cage framing size D90S, no. of poles of motor-6, start/hour-150, make –ALSTOM or equivalent. 7 Providing and Removing white or color wash by scrapping and sand papering , steel Brush , Air compressor and preparing the surface smooth including necessary repairs to scratches etc EOT Crane with scaffolding 20mtr height complete. 8 Providing of priming Coat With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works OF EOT CRANE including scaffolding. 9 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even/same shade, one or more coats on old work of EOT CRANE with scaffolding. 10 Complete job of Overhauling and greasing with alignment of track and replace of wheel roller, bearing of rail lines of complete job of crane with using scaffolding , chain pulley & other accessories 20mtr height. Load test will be done again after Complete bearings overhauling. 11 SITC of Distance /proximity sensors to measure the movement of Lifting beam during the operation of Gates and other allied work .Installation of HMI,PLC System based control panel of reputed make for exact measuring of gate travelling in meter for up and down movement with the help of Gear box and Encoder system along with complete wiring and other allied work. The screen at least 4ftx2ft on the both side of the girders of the crane. 12 SITC OF Load Display system of complete upgraded microprocessor controller safety system i.e Load cell. The upgrade system compatible to the Existing system fitted on the EOT crane functionally as well as physically. Display unit size 2ftx4ft is to installed on the both side of the grider of Eot crane and include overload hooter will automatically give the indication. The climate range 10degree to 5 degree throughout the year and with moisture during rainy season the display is ip66/65 waterproof. The display unit LED suitable for working day and night. 13 SITC OF Wireless Radio Remote (RRC)Control system to operate the Eot crane include Radio Remote Control , transmitter-joy stick type pushbutton type, Receiver ,Antenna And Cable ,Two set of Ni-Ah batteries and Battery charger. The remote control unit is operate to MAIN POWER , MAIN HOIST,LONG TRAVELL FORWARD & REVERSE AND ALSO Emergency Stop ON/OFF Control.The vendor shall consider all items whether or not specifically mentioned for successful completion of supply installation and commissioning of RRC system in Eot crane. Installation of RRC receiver, selector switch and interface panel/ junction box on Eot crane and laying and termination of cable betweenRRC receiver, interface panel/ junction box and crane control panels. Vendor shall consider lump Sum quantity for length of cable to be supplied for connections, Alternatively, vendor can visit site prior to submitting the bid for measurement if required, no additional payment for unit length of cable supplied will be allowed. Cables shall be connected on terminal blocks or must be property crimped and connected the receiver interface panel/junction box and crane Control panel. A selector switch shall be provided on the crane for selection of operation between pendant mode and RRC mode, Vendor has to submit two copies of connection diagrams of receiver, interface panel/ junction box and crane control panel. The vendor has to provide onsite training after successful testing and commissioning of the RRC system. 14 Alignment of gantry track by way of removal of old damaged part of track (approx. 20m)by way of dismantling of old rails and installation of new track wherever required by way of grouting and welding of new track with existing track. The job also includes alignment of new rails wherever required including welding of all rail joints, replacing the damaged clamp bolts. rail joints existing concrete. The alignment of the rails has to be done in accordance with the existing rails and the span, rail levels and alignment rails shall not exceed as per standard Tolerances. Packing should be provided where it is required and also application of epoxy mortar system of ASTM C-881 on oldConcrete and laser alignment of complete track.The material shall comply to IS: 800-2007 (or latest) - Indian StandardCode of practice for General Construction in steel.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
40.
Housing Urban and Rular Development #10911425 Price Bid
Tender for 2.28.1Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M , 2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 2.6.1 All Kinds Of Soil , 2.25Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. , 2.25(A)Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , 1.1.2Supplying And Filling Of Earth By Mechanical Transport Including Loading, Unloading & Stacking Beyond 5Km Upto 10Km & Beyond 10Km Upto 20Km (Including All) , 2.27Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , 2.35.3.1Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , 4.17Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone - Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. , 4.1.8Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 4.1.4Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 6.1.2Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 5.33.1.1Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Upto Plinth Level - Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.33.2.1Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.22.6Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , 5.22A6steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , 5.9.1Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases For Columns, Etc. For Mass Concrete , 5.9.6Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Abutments, Posts And Struts , 5.9.21Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers With Water Proof Ply 12 Mm Thick , 5.9.20Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Suspended Floors, Roofs, Landings, Balconies And Access Platform With Water Proof Ply 12 Mm Thick , 5.9.7Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Stairs, (Excluding Landings) Except Spiral-Staircases , 6.4.2Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 6.13.2Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , 6.15Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry , 13.2.215 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix: 1:6 (1 Cement: 6 Fine Sand) , 13.1.212 Mm Cement Plaster: 1:6 (1 Cement: 6 Fine Sand) , 13.16.16 Mm Cement Plaster Of Mix : 1:3 (1 Cement : 3 Fine Sand) , 10.15.1Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular/ L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , 9.20.1Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , 10.11.1Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side /Top /Centre Hung, With Beading And All Members Such As F7d,F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings,Glass Panes Complete All As Per Approved Design, (Sectional Weight Of Only Steel Members Shall Be Measured For Payment). Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , 10.3Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes , 9.48Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding , 9.51.2Providing And Fixing Fly Proof Galvanized M.S. Wire Gauge To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia 0.63 Mm All Complete. With Second Class Teak Wood Beading 62X19 Mm , 9.100.1Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125 Mm , 9.97.1Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :300X10 Mm , 9.96.1Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300X16 Mm , 9.103.1Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock, Isi Marked, With Six Levers And A Pair Of Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Aluminium Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. , 9.101.1Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade With Necessary Screws Etc. Complete. Single Rubber Stopper , 9.109Providing And Fixing Ptmt Door Catcher Of Length 72 Mm And Dia. Of 42 Mm With Suitable Washers Weighing Not Less Than 33 Gms , 8.31Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.41.2Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , 11.47.2Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is: 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately). Size Of Tile 600X600 Mm , 11.38Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. , 11.56.1Providing And Laying Polished Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing , Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. 11.56.1 Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent , 13.8Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.41.1Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Having Voc Content Less Than 50 Gram/Litre , 13.46.1Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sq M Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sq M) , 13.62.1Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , 10.26.1Providing And Fixing Hand Rail Of Approved Size By Welding Etc. To Steel Ladder Railing, Balcony Railing, Staircase Railing And Similar Works, Including Applying Priming Coat Of Approved Steel Primer. M.S. Tube , 22.5Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : (A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. (B) Second Layer Of Slurry Of Cement @ 0.242 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. (The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 5.3Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections. , 22.1.Iproviding And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: (A) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. (B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge. (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : 22.7.1 With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. , 18.7.1Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.15 Mm Dia , 18.7.2Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.20 Mm Dia , 18.7.3Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.25 Mm Dia , 18.7.4Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.32 Mm Dia , 18.7.5Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.40 Mm Dia , 18.7.6Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply And All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.50 Mm Dia , 18.9.7Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge , 18.51.1Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore , 18.84.1Providing & Fixing Chrome Plated Brass Battery Based Infrared Sensor Operated Pillar Cock, Having Foam Flow Technology. , 18.53.1Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 , 18.10.1Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc. Internal Work - Exposed On Wall 15 Mm Dia , 18.10.3Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc. Internal Work - Exposed On Wall 25 Mm Dia , 18.10.6Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc. Internal Work - Exposed On Wall 50 Mm Dia , 18.18.1Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 15 Mm Normal Bore , 18.18.2Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 20 Mm Normal Bore , 18.17.1Aproviding And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Noramal Bore , 18.17.1Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 25 Mm Noramal Bore , 18.19.5.1Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : , 18.48Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. , 17.3.1Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , 17.16Aproviding And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In - Charge , 17.7.8Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , 17.10.1Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board - 510X1040 Mm Bowl Depth 250 Mm , 17.69.2Providing And Fixing Ptmt Waste Coupling For Wash Basin And Sink, Of Approved Quality And Colour. Waste Coupling 38 Mm Dia Of 83 Mm Length And 77 Mm Breadth, Weighing Not Less Than 60 Gms , 17.28.2.1Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 32 Mm Dia , 17.22Aproviding And Fixing Cp Brass 32Mm Size Bottle Trap Of Approved Quality & Make And As Per The Direction Of Engineer-In-Charge. , 17.22Bproviding And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. , 17.35.1.3Providing And Fixing Soil , Waste And Vent Pipes: Hubless Centrifugally Cast (Spun) Iron Pipes Epoxy Coated Inside & Outside Is:15905 100 Mm Dia , 17.35.2.3Providing And Fixing Soil , Waste And Vent Pipes: Hubless Centrifugally Cast (Spun) Iron Pipes Epoxy Coated Inside & Outside Is:15905 75 Mm Dia , 18.65Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. , 17.37.1Providing And Fixing M.S Holder-Bat Clamps Of Approved Design To Sand Cast Iron/ Cast Iron (Spun) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10 Cm Of 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) Including Cost Of Cutting Holes And Making Good The Walls Etc. 100 Mm Dia , 17.37.2Providing And Fixing M.S Holder-Bat Clamps Of Approved Design To Sand Cast Iron/ Cast Iron (Spun) Pipe Embedded In And Including Cement Concrete Blocks 10X10x10 Cm Of 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) Including Cost Of Cutting Holes And Making Good The Walls Etc. 75 Mm Dia , 17.38.1.1Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete 100 Mm Dia , 17.38.2.1Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete 75 Mm Dia , 17.39.1.1Providing And Fixing Plain Bend Of Required Degree Sand Cast Iron S&S As Per Is - 1729 100 Mm Dia , 17.39.2.1Providing And Fixing Plain Bend Of Required Degree Sand Cast Iron S&S As Per Is - 1729 75 Mm Dia , 17.60.1.2Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : Sand Cast Iron S&S As Per Is: 1729 100 Mm Inlet And 100 Mm Outlet , 17.60.2.2Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : Sand Cast Iron S&S As Per Is: 1729 100 Mm Inlet And 75 Mm Outlet , 17.32.1Providing And Fixing Mirror Of Superior Glass (Of Approved Quality) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing , 17.56.1.1Providing And Fixing Terminal Guard Sand Cast Iron S&S As Per Is - 1729 100 Mm Dia , 17.56.2.1Providing And Fixing Terminal Guard Sand Cast Iron S&S As Per Is - 1729 75 Mm Dia , 17.57.1.1Providing And Fixing Collar : Sand Cast Iron S&S As Per Is - 1729 100 Mm Dia , 17.57.2.1Providing And Fixing Collar : Sand Cast Iron S&S As Per Is - 1729 75 Mm Dia , 17.71Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms , 17.72Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215Mm Long, 200Mm Nos. Wide With A Minimum Distances Of 37Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colours Weighing Not Less Than 80 Gms , 17.73.2Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. (For Bath) , 17.74Providing And Fixing Ptmt Shelf 440 Mm Long, 124 Mm Width And 36 Mm Height Of Approved Quality And Colour, Weighing Not Less Than 300 Gms. , 18.22.1Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 100 Mm Diameter , 18.77Cutting Holes Up To 15X15 Cm In Reinforced Cement Concrete Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Including Finishing Complete So As To Make It Leak Proof. , 12.41.2Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes. , 2.8.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 2.8.1 All Kinds Of Soil , 5.9.5Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , 5.9.3Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.2Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , 5.10.4Providing And Fixing Tie Bolt, Spring Coil And Plastic Cone In Wall Shuttering Complete As Per The Direction Of Engineer-In-Charge.20 Mm Dia.& 225 Mm Length , 13.7.212 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement :1:4 (1 Cement : 4 Fine Sand) , 19.32.1Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design.With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , 5.1.2Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level [ 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii): 3 Graded Stone Aggregate 20 Mm Nominal Size) ] , 5.2.2Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size) , 6.4.1Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , 16.53.1Providing And Fixing Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 Metre Openable Length ( Total Length 90 M), Having 50 Nos Rounds Per 6 Metre Length, Upto 3 M Height Of Wall With Existing Angle Iron ‘Y Shaped Placed 2.4M Or 3.00 M Apart And With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape(R.B.T.) / Spring Core (2.5Mm Thick) Wire Of High Tensile Strength Of 165 Kg/ Sq.Mm With Tape (0.52 Mm Thick) And Weight 43.478 Gm/ Metre (Cost Of M.S. Angle, Cement Concrete Blocks Shall Be Paid Separately) , 1.1.2Supplying And Filling Of Earth By Mechanical Transport Including Loading, Unloading & Stacking Beyond 5Km Upto 10Km & Beyond 10Km Upto 20Km (Including All) , 16.92.1Providing And Fixing 10X10x7.50 Cm Granite Stone Block Hand Cut And Chisel Dressed On Top, For Paving In Floors, Drains Etc. Laid Over 20 Mm Thick Base Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints 10 Mm Wide Filled With Same Mortar Including Ruled Pointing Etc. Complete As Per Direction Of Engineer-In-Charge. , 16.69.1Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Making Joints With Or Without Grooves (Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5Mm), Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer-In-Charge (Length Of Finished Kerb Edging Shall Be Measured For Payment). (Precast cement concrete Kerb Stone Shall Be Approved By Engineer-In-Charge) , Aor2019supply, Installation, Testing And Commissioning Of Ongrid Solar Photovoltaic Power Plant Conforming To Mnre Specifications As Amended, Consisting Of Mono/Poly Crystalline Silicon Solar Cells, Net Metering Facility, Necessary Protections, Earthing, Mounted On Aluminium/Gi Structure Of Suitable Strength With Following Components Complete As Required:- A) Solar Photovoltaic Module Of Capacity 330 Wp Or Above, Manufactured In India, Conforming To Is 14286/Iec 61215, Is/Iec 61730-Part-1, Is/Iec 61730-Part-2. Solar Photovoltaic Module Conversion Efficiency Shall Not Be Less Than 16.5%. Pv Modules Used In Solar Power Plants/ Systems Must Be Warranted For Their Output Peak Watt Capacity, Which Should Not Be Less Than 90% At The End Of 10 Years And 80% At The End Of 25 Years. B) Power Conditioning Unit (Pcu) Of 350-800 V Dc Input Voltage Range And 400 V Ac, Three Phase, 4 Wire, 50Hz +/- 2.5 Hz, Output Voltage Suitable To Generate Ac Power With Efficiency Not Less Than 97%, Total Harmonic Distortion Less Than 3% And Suitable For Ambient Temperature From 0 To 50 Degree C. The Pcu Shall Adjust The Voltage And Frequency Level To Suit The Grid Voltage Frequency. , 2-2 Miscconcrete With Cement, Coarse Sand And 40Mm Gauge Stone Ballast In Proportion 1:4:8 In Foundations And Floors Including Supply Of All Material, Labour And T&P Etc. Required For Proper Completion Of The Work. As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 , 4-2-4 Mordgravel/Soil Aggregate Base/Subbase Nominal Maximum Size Grading 80 Mm (Table 2.3 Of Irc Sp 77-2008) Construction Of Gravel/ Soil Aggregate Subbase/ Base By Providing Well Graded Material Of Nominal Maximum Size Grading 80 Mm As Per Table 2.3 Of Irc Sp 772008, Spreading In Uniform Layers With Tractor Mount Appropriate Grading Arrangements On Prepared Surface, Mixing By Mix In Place Method At Omc With Tractor Mount Appropriate Rotavator Attachment And Compaction With Three Wheel 80100 Kn Static Roller Capacity To Achieve The Desired Density Complete As Per Specifications Contained In Para 2.2, 3.6 And 3.7 Of Irc Sp 77-2008. , 4-7-3A Mordwater Bound Macadam Sub-Base/Base Wbm Grading 3 Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screening To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 3 As Per Technical Specification Clause 405. By Manual Means , 2-3 Misccement Concrete (Pcc M-30) Pavement:- Construction Of Un-Reinforced, Cement Concrete Pavement, Thickness As Per Design, Over A Prepeared Sub Base With 43 Grade Cement Or Any Other Type Plain Cement Concrete Grade M 30, Coarse And Fine Aggregates Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Concrete Mixer Of Not Less Then 0.2 Cum Capacity And Appropriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of Wedges, Steel Plates Including Levelling The Formwork, As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, And Plate Vibrators, Finished In Continuous Operation And Curing Of Concrete Slabs For 14 Days, Using Curing Compound Where Specified And Water Finishing To Lines And Grade As Per Drawings And Technical Specifications. , 1.10.3Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , .1.12Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loopearthing As Required , 1.14.1Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire (For Circuit Wiring & Light Plug Wiring) , 1.14.2Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 6 Sq. Mm + 1 X 6 Sq. Mm (For Single Phase Db. From Sub Panel To Db) , 1.14.4Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required4 X 6 Sq. Mm + 2 X 6 Sq. Mm (For Three Phase Db. From Sub Panel To Db) , 1.14.9Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 4 X 10 Sq. Mm + 2 X 6 Sq. Mm (For Three Phase Db. From Sub Panel To Db) , 1.14.10Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 4 X 16 Sq. Mm + 2 X 16 Sq. Mm (For Three Phase Db. From Sub Panel To Db) , 1.14.11Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 4 X 16 Sq. Mm + 2 X 16 Sq. Mm (For Three Phase Db. From Sub Panel To Db) , 1.24.1Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 5/6 A Switch , 1.24.4Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 3 Pin 5/6 A Socket Outlet , 1.24.3Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 15/16 A Switch , 1.24.5Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required 6 Pin 15/16 A Socket Outlet , .1.31Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 A Modular Socket Outlet And 5/6 A Modular Switch, Connections Etc. As Required. , .1.32Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required. , .2.19Supplying And Fixing 20 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. , .1.25Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , .1.33Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connections Etc. As Required. , .1.34Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required , 1.27.1Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required.1 Or 2 Module (75Mmx75mm) , 1.24.7Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Tv Antenna Socket Outle , 1.24.8Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. Reqired Bell Push , 1.21.1Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 1.21.2Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25 Mm , 1.53.1Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 1 Run Of Cable , .1.41Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Complete With All Accessories And Tube/Lamp Etc. Directly On Ceiling/ Wall, Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , 1.50.1Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , .1.51Extra For Fixing The Louvers/ Shutters Complete With Frame For A Exhaust Fan Of All Sizes. , .10.18Providing And Fixing Circular/ Hexagonal Cast Iron Or M.S. Sheet Box For Ceiling Fan Clamp, Of Internal Dia 140 Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick M.S. Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The Cast Iron/ M.S. Sheet Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners. Clamp Shall Be Made Of 12 Mm Dia M.S. Bar Bent To Shape As Per Standard Drawing. , .19.1Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cm/M/W) Minimum 6.00, Air Delivery Minimum 210 Cum/Min , 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. , 2.10.1Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , .2.11Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. , 2.3.2Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 8 Way Double Door , 2.4.3Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 8 Way (4 + 24), Double Door , 2.13.1Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40A , 2.13.2Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63A , 2.14.1Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 A , 2.14.2Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 A , 2.14.3Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63A , 7.1.2Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required.Above 35 Sq. Mm And Upto 95 Sq. Mm , 9.1.13Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 X 95 Sq. Mm (38Mm) , 4.6.1Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray (Galvanisation Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.6.2Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray (Galvanisation Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.6.3Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray (Galvanisation Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.225 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.6.6Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray (Galvanisation Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness , 4.7.1Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Bends (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.7.2Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Bends (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.125 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.7.3Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Bends (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.250 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.7.6Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Bends (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness , 4.8.1Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Tee (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required 100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.8.2Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Tee (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.8.3Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Tee (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required 250 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.8.6Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Tee (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required 450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness , 4.9.1Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Cross Member(Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.9.2Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Cross Member(Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.9.3Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Cross Member(Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.250 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.9.6Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Cross Member(Galvanisation Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness , 4.10.1Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Reducer (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.10.2Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Reducer (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.10.3Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Reducer (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.250 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.10.6Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Reducer (Galvanisation Not Less Than 50 Microns) With Perforation Not More Than17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc As Required.450 Mm Width X 50 Mm Depth X 2.0 Mm Thickness , Nsithe Maximum Allowable Temperature For The Bus Bar To Be Restricted To 90 Deg C. The Temperature Rise Should Be Restricted To 45 Deg C Above Ambient Temperature.Complete Panel As Above And Complete , Gemsproviding And Supplying Of Led Batten 20 Watts 1150 Mm , Gemsproviding And Supplying Of 9W Led Bulb With Battery-Is:16102, Warranty For Free Replacement 1 Year , Gemsproviding And Supplying Of 12W Warm White Ceramic Circular Led Surface Ceiling Light , Gemsproviding And Supplying Of 1200Mm Bldc Motor Electric Ceiling Fan , Gemsproviding And Supplying Of Aluminium Wall Fan 2 Year Warranty , Gemsproviding And Supplying Of Exhaust Fan 300 Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
41.
Public Administrative Department #10894424 Price Bid
Tender for Ashok Leyland , Air Cleaner Assembly , Air Compressor , Br. Hose Assy , Brake Hose , Bundy Pipe Sub Assy , Compressor Delivery Pipe , Connecting Rod Assy , Crank Shaft , Cylinder Block , Cylinderhead , Drier And Distributor Valve , Gear Air Compressor Drive (Alt - F1661111) , Hose Assy , Kit-Air Intake System Comp , Low Pressure Indicator Switch , Major Repair Kit , Piston Assy- Std , Piston Repair Kit , Pre-Cleaner (Metal) , Primary Filter , Reed Valve Assy , Secondary Filter , Clutch Back Plate Kit , Clutch Bush Pin Kit , Clutch Disc Facing , Clutch Operating Lever , Clutch Plate Lever , Clutch Repair Kit , Clutch Rocking Shaft , Clutch S/C Major Kit , Clutch Withdrawl Bearing , Clutch Withdrawl Sleeve , Drag Link Assembly , Driving Plate , Lever On Shaft-Outer , Lipe Ceramic Clutch Disc (Alt - B1307001) , Rdc Clutch Cover Sub Assy. , Rdc Spring Kit , Slave Cylinder , 550Mm Ring Fan And Fan Clutch , Cac Inlet Pipe Hose - Engine Side , Cac Outlet Pipe , Cac-Inlet Hose , Cyilicon Hose , Hose - Radiator Inlet Radiator Side , L-Hose , L-Hose - Radiator Piping , Pipe -Turbo Outlet To Cac Inlet , Poly V. Pulley , Radiator Assy , Radiator Inlet Pipe , Ring Fan 550Mm Dia 7 Blade , Side Stay - Radiator Moungting , Tank Assy-Rad.Supp Ly , Turbo Outlet Pipe -Cac , Water Pump , Adjuster Ring , Carrier Mounting Fasterners Kit , Diff Brg , Diff Case & Nest Assy , Diff Spider Kit , Drive Gear & Pinion , Inner Bearing , Oil Seal & Pinion Nut Kit , Oil Seal Assy.-Flange , Outer Bearing , Pilot Bearing , Pinion Cage Assy , Pinion Cage Hardware Kit , Shim Kit-Pinion , Spacer Kit-Drive Pinion , Thrust Screw & Jam Nut Kit , Thrust Washer Kit , 4 Chamber Tail Lamp Rh , 55A Alternator (Lucas) Alt To X7489100 , Armature , Armature Assembly , Battery Cable - Battery +Ve To Isolator Sw , Battery Cable - Battery -Ve To Chasis , Battery Inter Connector , Battery Positive Cable , Bearing Bush Assembling Kit , Bearing Bush Assembling Kit , Brush Assembling Kit , Brush Gear Assembly , Brush Holder , Buzzer , Ce Bracket & Bush Assy. , Commutator End Shield , De Bearing Assembling Kit , Drive Assembly , Excitation Winding , Fasteners Assembling Kit , Field Coil With Thermal Cutout , Fog Lamp Assy , Head Lamp Assy , Horn Assembly , Ignition strengthening Lock , Intermediate Bearing , Isolator Switch Assy , Lead Assembly , Overrunning-Clutch , Plunger Assembly , Pulley , Rear Work Lamp , Rectifier Assembly , Relay Assembly , Rotor Assembly , Sealing Assembling Kit , Solenoid Switch , Solenoid Switch Assembly , Sre Ball Bearing , Starter Motor-Ltvs-24V-Pre-Engaged With , Stator Winding Assembly , Tail Lamp Assy Lh , Turn Signal Indicator , Wiper Arm And Blade Assembly - Driver Side , Wiper Kit Assembly , Wiping System (Kit) , Wiring Harness For Ve Cluster , Adaptor , Oil Fil , Adaptor Bracket , Air Intake Pipe , Ball Bearing, Alt - X0206110 , Bolt Con-Rod , Bolt, Bearing Cap , Breather Hose With Inner Spring , Bushing Con Rod , Camshaft , Camshaft Bush Kit , Composite Valve Kit , Composite Valve Seat Kit , Con Rod Bearing Kit , Con Rod Bearing Kit , Connecting Rod , Crank Shaft Main Bearing Set , Crankshaft, Microalloyed , Damper, , Decarbonising Gasket Kit , Dipstick And Guide , Element Oil Cooler Sub Assy. , 6 Plates , Engine Cylinder Head Assy. , Engine Mounting Bracket , Engine Mounting Bracket , Exhaust Valve , Fly Wheel Bearing Ball , Fly Wheel Ring Gear , Front End Plate Gasket , Gasket Cylinder Head , Gasket Over Hauling Kit- Complete , Gear Crankshaft , Gear, Camshaft Alt To F1661211 , Idler Gear , Intake Manifold , Intake Valve , Liner Cylinder S/S , Manifold, Exhaust , Oil Cooler Gasket , Oil Pump , Oil Strainer Sub Assy. , Piston Ring Set- , Piston Set(With Pin) , Piston,Pin And Ring Set , Plate, Front End Timing Back Plate , Rocker Arm , Rocker Shaft , S/A First Pipe Silencer , Second Pipe Sub Assembly , Series C/S Rear End Plate Oil Seal , Spacer , Special Flanged Bolt , Tail Pipe Assy , Thermostat , Thrust Washer Set - Std , Valve Guide Kit , Valve Intake Seat , Valve Spring Inner , Valve-Exhaust Seat , Brake Drum , Cover Plate For King Pin , Distance Piece- , Front Axle Taper Roller Bearing , Front Hub , Hub Cap , Joint Cover Plate , M20 Bolt For Fa 99 Track Rod Lever Mountg. , Oil Seal - Hub , Ring For Oil Seal , Steering Lever , Track Rod Assembly , Track Rod Lever , 200L Tank Comp Sub Assy , Camshaft , Control Rod , Delivery - Valve Assembly , Delivery - Valve Holder , Flywheel Coupling , Fuel Filter Cum Water Separator , Fuel Hose - Suction Sub Assy , Fuel Sensor Unit , Gear Injection Pump Drive , Hose Assembly-Filter To Fip , Hose Assy - Feed Pump To Fuelfilter Cum W/S , Injector Assy , Overflow Valve , Roller Tappet , Shut Off Solenoid 24V , Strainer Assy , Tapered-Roller Bearing , Timer For Shut Off Solenoid (24V) , Circlip Kit , Const.Mesh Gear On Lay Shaft , Cover-Reverse Idler (Sheet Metal) , Fixed Dog Clutch Reverse , Gasket , Gear Change Finger , Gear On Main Shaft , Input Shaft , Joint , Layshaft(Counter Shaft) , Main Shaft , Needle Roller Bearing , O/D Gear On Layshaft , O/D Gear On Mainshaft , Oil Seal , Rev. Gear On Ms , Reverse Idler Gear , Reverse Idler Pin , Reverse Selector Fork , Roller Bearing ( Alt. Part No. F0259210 ) , Roller Bearing Rear ( Alt .F0259310 ) , Selector Fork , Selector Housing , Selector Shaft , Sliding Pad(Selector Pad) , Sliding Sleeve , Spigot Bearing , Synchro Cone , Synchro Pack , Taper Roller Bearing , Zf Gear Box Gasket Kit , Zf Seal Kit , Bracket - Shock Absorber , Centre Bolt & Nut Kit , Front Shock Absorber , Front Spring , Rear Spring , Shackle Pin , Shock Absorber Mounting , Spring Eye Bush , Spring Shackle , Spring Shackle Sub Assy , U Bolt , Assembly Proximity Mirror , Door Glass , Door Lock Assembly Kit , Filter Element , Fuel Gauge , Housing Cover Assy. R.H. , Oil Tank Assy. , Rpm Meter With Hour Meter , S/A Of Acceleration Bracket And Shaft , Sealing Kit , Sector Shaft Assy. , Shaft And Lever Assembly - Throt , Small Component Kit , Speedo Movement Ratio , Temperature Gauge , Weatherstrip - Door Glass Channel , Windscreen Glass , Windscreen Rubber Beading , Cb Kit Assembly , Companion Flange , Flange Yoke For Drive Shaft , Mid Ship Tube Shaft , Msts Nut , Propeller Shaft Kit , Slip Yoke Assembly , Tube Shaft , Tube Yoke , Uj Kit , Anchor Pin-Brake Shoe , Axle Shaft Long , Axle Shaft -Short , Bracket Mounting Fasteners Kit Comp , Brake Chamber Repair Kit , Brake Drum , Brake Lining Front , Brake Lining Rear , Brake Minor Repair Kit- , Brake Pedal , Brake Spring Kit , Bushing - Cam , Camshaft , Camshaft Repair Kit , Camshaft Washers Kit Comp , Clutch Pedal , Fulcrum Pin , Gasket , Gasket-Bracket & Spider , Hand Brake Valve , Hub Bearing , Kit Lining Set-Std Comp , M.C.Kit , Major Repair Kit- (Rear Brake) , Mc Assembly , Minor Repair Kit , Mtg Bracketbattery Carrier , Oil Seal , Oil Seal Ring-Outer , Rear Hub , Repair Kit For Dual Brake Valve , Repair Kit For Rear Brake Chamber , Return Spring-Brake Shoe , Roller , Front Tyre , Rear Tyre , S/A Of Pedal Bracket , Stud For Axle Shaft , Wheel Bolt , Bonnet Adjustment , Removing And Replacing Of Door Handle , Removing And Replacing Of Door Lock , Removing And Replacing Of Rear Back Light , Replacement Of Channel Set And Bidding Set , Replacement Of Door Bidding Set , Replacement Of Door Canned Set , Replacement Of Door Glass Each , Replacement Of Door Gola , Replacement Of Door Handle Set , Replacement Of Front And Rear Bumper , Replacement Of Front Wind Glass , Replacement Of Roof Upholstery , Replacing Door Hinges Pins Of Each Door , Replacing Door Window Regulator , Exhaust Elbow , Oil Drain Pipe, Flexible - Turbo Charger , Turbo Charger , Turbo Charger With Adaptor Sub Assy , Wheels & Tyres , Bearing , Bearing Lower Teeeth 36 , Dipcase Bearing , Front Hub Bearing , King Pin Bearing T-149 , Main Shaft Bearing , Needle Bearing , Pinion Bearing , Planet Gear Bearing , Rear Wheel Bearing , Reversal Bearing , Transmission Bearing , Accelerator Cable Spring , Black Pad Nylon , Blue Pad Nylon , Boom Clip , Boom Shim , Boom Stablizer Spring , Bucket Ball Joint , Bucket Pin Washer , Bucket Shim , Cabin Mounting , Circlip , Clamp Bolt With Nut , Collapsible Tube , Dipper Shim , Engine Mounting , Externat Circlip , Grease Nipple , Green Pad Nylon , Hub Cover Plate , Hub Plug , Hydra Clamp Nut , Hydraulic Valve Protection Pad , King Pin Shim , King Post Bolt , Kpc Shim , Lower Cab Mounting , Lower Wear Pad Plastic , Oil Drain Plug , Pinion Nut , Protection Pin , Rear Axle Nut , Rear Hub Stud With Nut , Rear Wheel Nut , Red Pad Nylon , Rubber Mounting , Slew Ram Bolt , Stabilizer Wear Pad Nylon Type , Steel Washer , Strap , Throttle Overload Spring , Throttle Pedal Spring , Thrust Pad , Thrust Washer , Turret Seat Thick , Turret Washer Thin , Upper Cab Mounting , Upper Wear Pad Small Plastic , Wear Pad , Yellow Pad , Brake Booster , Brake Disc , Brake Friction Plate , Brake Master Cylinder , Brake Pedal Spring , Brake Piston , Brake Plate , Driven Plate Kit , Friction Plate , Boom Bush , Bucket Pin Bush , Bucket Rod Bush , Cut Bush , Cylinder Bushing Mount Holder , Dipper Rod Bush , Front Axle Bush , King Pin Bush , King Post Bush , Linear Bearing , Loader Arm Bush , Slew Rod Bush , Steel Bush , Steering Axle Bush , Steering Bush , Tie Rod Bush , Tipping Link Bush , Twin Cylinder Bush , Door Handle , Door Latch Assy Rh , Door Lock , Engine Side Panel Rh , Fender , Grill , Leg Rain Cap , Side Window Handle , Steering Wheel , Steering Wheel Knob , Cable , Cable Lever , Gas Strut , Throttle Cable , Throttle Cable With Handle , Alternator , Coil 12V , Diffuser Direction , Front Lamp Assy. , Fuel Level Indicator , Glow Plug , Ignition Switch , Rear Lamp , Rear Lamp , Rear Lamp Assy. , Rear Light , Rear Light Len , Rear Worklight , Refrigerant Fluid Temperature , Solenoid , Solenoid Assy , Solenoid Valve , Starter Motor , Switch Reverse - Forward , Tachometer Hour Meter , Tachometer Revolution Meter , Temperatur Guage , Temperature Sensor , Thermostat Housing , Belt Tensioner , Connecting Rod , Connecting Rod Bush , Crank Shaft Pulley , Crank Shaft Pulley , Diesel Fuel Cap , Dipstick , Elbow Hose , Electrical Valve Gasket , Engine Cooling Fan 21 , Engine Oil Dip Stick , Engine Piston , Engine Valve , Exhaust Elbow , Filter Glaas Bowl , Fly Wheel Ring Gear , Fuel Leak Off Assy. , Fuel Pipe , Fuel Pump , Fuel Sediment Filter Assy , Fuel Tank Cap With Keys (Small) , Gasket Set , High Pressure Pipe 3&4 , Hydraulic Level Guage , Hydraulic Tank Sight Guage , Oil Cooler Gasket , Oil Filler Cap , Oil Pump , Pipe Fuel Filter To Fuel Injection Pump , Preleaner Assy , Preleaner Glass , Pressure Cap , Push Rod , Radiator Hose Bottom , Rocker Cover Gasket , Top Radiator Hose , Valve Collet , Valve Seat , Water Hose Bottom , Water Pump , Watern Hose Bottom , Yellow Cap , Air Filter , Air Filter Assy , Engine Oil Filter , Fluid Reservoir , Fuel Filter , Fuel Filter Assy. , Fuel Filter , Hydraulic Filter , Hydraulic Filter Long Type , Hydraulic Filter , Hydraulic Tank Strainer , Reservoir , Suction Strainer , Transmission Filter , Auxillary Relief Valve , Hyd. Pump Centre Body , Hyd. Pump Drive Gear Shaft Big , Hyd. Pump Flange With Bushes , Hyd. Pump Gear Set , Hyd. Pump Plate Bush , Hyd. Pump Seal Kit , Hyd. Pump Wear Plate , Hydra Clamp Housing , Hydraulic Pump , Hydraulic Pump Key , Hydraulic Pump , Main Relief Valve , Pilot Unloader Valve , Single Pump With Gear 36Cc , Spool Valve , Vaccum Pump With Gear , Centre Pin , Pivot Pin , Pivot Pin Boom Knose , Axle Oil Seal , Brake Piston Ring , Brake Piston Seal , Clutch Seal , Cylinder Seal Kit , Distributor Slider Seal , Dust Seal , Front Axle Crossover Seal , Front Axle Ring , Front Engine Seal , Fuel Injection Seal , Fuel Settler Ring , Gearbox Seal , Hub Oil Seal , Hub Seal , Hydra Clamp Seal , Hydraulic Tank Gasket , Hydraulic Valve Seal , King Pin Seal , O Ring , Oil Seal , Pin Seal , Pinion Cover Slew Gasket , Piston Seal Kit , Rear Engine Seal , Seal Ring , Slew Swing Cylinder Seal Kit , Steering Cyllinder Seal Kit , Transmission Filter Gasket , Transmission Piston Inner , Transmission Pump Ring , Transmission Pump Seal , Transmission Shaft Teflon Ring , Valve Stem Seal , Water Inlet Gasket , Wiper Seal , Orbital Assy. , Pressure Relief Valve Steering , Rack End , Steering Coupling , Tie Rod Assy. , Centre Tooth , Side Cutter , Adaptor Block Assy. , Annulus Carrier , Annulus Ring , Brake Gear , C.W. Stud , Carriage , Clutch Housing With Gear , Clutch Housing With Gear , Cross Universal Joint , Crown Wheel & Pinion Assy. , Crown Wheel & Pinion Set , Differential Case Assy. , Differential Cross , Differential Gear Set O/M , Differential Washer Set , Double Joint Yoke , Drive Shafts , Foot Side Shift Stablizer , Front Axle Crossover Trunion , Front Drive Shaft , Front Hub , Gear Charging Pump , Gear Lever Rubber Boot , Gear Lever Rubber Cap , Gear Shift Lever Tension Spring , Gear Shift Lever , Hydra Clamp Housing O/M , King Post , Kingpost Carriage , Layshaft , Pinion Drive Gear , Pinion Gear , Pinion Shaft , Planetary Gear , Power Steering Pump , Pump Drive Shaft , Pump Shaft Yoke , Rear Axle Drive Shaft , Rear Hub , Steering Pump , Stub Axle Carrier , Sun Gear , Synchroniser Sleeve , Synchronizer Assy. , Terrot Housing O/M , Tipping Lever , Tipping Link , Tippining Liver , Transmission Piston , Trunnion , Yoke Coupling , Yoke Flange , Yoke Flange , Wheels & Tyres , Mahindra Bolero , Gear Fork , Gear Pinion , Air Cleaner Hose Pipe , Air Pressure Horn , Alternator Stator , Alternator Bearing (Roller Type) , Alternator Bushing , Alternator Carbon , Alternator Cashing , Alternator Commulator , Alternator Cutout , Alternator Dunamo Assly , Alternator Rectifire (Positive/Neg.) , Alternator Rotter , Axle Bearing , Back Gear Pinion , Back Light Assly. , Battrey Terminal , Benet Hook With Clip , Benet Monogram , Benet Tana Rod , Black Tap (Big) , Body Mounting , Brake Fexiable Pipe , Brake Lining , Bumper End , Bumper Gutka , Cam Shaft Bush/Bearing , Car Fan , Carbon Holder , Carburator Assly. , Carburator Butter Fly , Carburator Repair Kit (Major) , Chamber Bolt , Chamber Gasket , Clutch Adjusting Rod , Clutch Cable Assly , Clutch Plate Assly. (Plain/W/Facing) , Clutch Release Bearing Hub , Clutch Spring , Condenser , Connecting Bearing , Connector , Counter Gear Assly , Counter Gear Pinion , Counter Shaft Pin , Counter Shaft Roller , Counter Shaft Thrust Washer , Crank Shaft Bearing , Cross Holder , Cross Member , Cross Member , Cross Member Front Assly , Cross Member Rear Assly , Crown & Tail Pinion Assly. , Diesel Filter Assly , Diesel Flexiable Pipe , Differential Crown Pinion Shaft , Differential Gasket , Differential Oil Seal , Digi Rubber , Distributor Assembly , Distributor Cap , Distributor Plate Assly , Door Glass Handle , Door Glass Machine , Door Glass Rubber , Door Glass Channel , Door Half Lock , Door Handle/Lock/Kabja , Door Lock Assambly , Door Regulator Machine , Driving Glass , Dynamo Alternator Pully , Engine Cross Member , Engine Head Bolt , Engine Head Gasket (Full Set) , Engine Head Gasket (Single Pice) , Engine Head Stud F/T , Engine Main Bearing , Engine Mounting , Engine Valve (Inlet & Exhust) , Fan Assly , Fan Belt , Feed Pump Assly , Flang Stand (Double/Single) , Flasher , Fly Wheel Bearing , Fog Light Assly , Fog Light Bulb , Foot Board , Front Shockobsorbar , Front Spring , Front Spring Hanger , Front Spring Main Leaf , Front Spring Shackle Bush , Front Spring Shackle Pin , Fuel Meter , Gear Box Gasket , Gear Box Mounting , Gear Box Oil Seal , Gear Box Seal Kit , Gear Box Thrust Washer , Gear Lever Fork , Grill Assly , H T Wire , Head Light Assly , Head Light Bulb , Head Light Bulb , Head Light Holder , Head Light Seal Beam , Head Light Switch , Heater Plug , Heater Switch , Hood Light Assly , Ignation Switch , Gear Pinion , King Pin Bearing , King Pin , King Pin Oil Seal , L T Wire , Looking Glass (Rear View Mirror) , Main Bearing Coller Oil Seal , Main Shaft Assly , Main Shaft Bearing , Main Shaft Locknut/Oil Seal/Roller/Washer , Manifold Gasket , Master Cylender Assly , Mobile Filter Flexible Pipe , Mounting Buffer , Mudgard Bolt (F/T) , Oil Filter Element , Oil Pressure Switch , Oil Pump Assly , Parking Light Glass , Petrol Tank Assly , Petrol Tank Cap With Key , Petrol Tank Caps Rubber , Petrol Tank Hose Pipe , Petrol Tank Pipe (Steel) , Pisto Ring , Pisto Sleeve , Pisto With Pin , Plastic Tap , Plug Socket , Pressure Plate Assly , Propular Shaft Bolt , Propular Shaft Centre Bearing , Propular Shaft Teeth , Propular Shaft U Bolt , Propular Shaft Youk , Push Pull Switch , Radiator Assly. , Radiator Cap , Radiator Hose Pipe (Uper,Lower) , Radiator Hose Pipe Clamp , Rear Spring Clamp , Rear Spring Leaf , Rear Spring Centre Bolt , Rear Spring Clamp Bolt , Rear Spring Main Leaf , Rear Spring Mounting , Rear Spring Mounting Bolt , Rear Spring Shackle Assly , Rear Spring Shackle Bush Steel , Rear Spring Shacklr Pin , Rear Spring U Bolt , Release Carbon , Rotter , Self Carbon , Self Bushing , Self Housing Plate (Bushing/Brg. Side) , Self Housing Armature 12 Volt , Self Housing Field Post , Self Housing Plate (Carbon Side) , Self Starter Assly , Self Starter Bandix Assly , Self Starter Bushing Cover , Self Starter Solenied Switch , Self Starter Switch , Servo Assly , Shim Washer , Shockobsorber Bolt , Shockobsorber (H/ Duty) , Side Light Assly , Side Light Bulb , Side Light Glass , Side Light Holder , Side Light Switch , Silencer Box (Muffler) , Silencer Clamp , Silencer Gasket ( O) Ring , Sparking Plug , Spedo Meter Cable Assly. , Spedo Meter , Spedo Meter Pinion , Spring Clamp , Spring Clamp Bolt , Spring Show Mounting , Spring U Bolt (Front) , Starting Pully , Steering Box Assly , Steering Collumn , Steering Demper Bush , Steering Rack Assly , Steering Sector Oil Seal , Steering Sector Shaft With Gear , Steering Bolt Joint (Tie-Rod) , Steering Bolt Joint Lock , Steering Combination Switch , Steering Control Rod , Steering Demper Bushing Kit , Steering Horn Bottom Switch , Steering Knockle Kit , Stop Light Switch , Sttring Lever Switch , Sttring Wheel , Sttring Wheel Bush , Sttring Wheel Cover , Suspension Bushing Kit(Major) , Sycronizer Lock Ring , Sycronizer Lock(Maghi Lock) , Sycronizer Spring , Sycronizer Assly , Syncronizer Brass Ring , Tail Pinion Bearing , Tank Float Unit , Tappet Cover Gas Ket , Tie Rod End Drive Set , Tie Rod Pipe , Timing Chain , Top Shaft Assly , Top Shaft Bearing , Top Shaft Oil Seal , Top Shaft Pinion , Top Shaft Roller , Vaccum Horn Pipe , Valve Lock , Valve Oil Seal , Water Pump Gasket , Water Pump Assly , Water Pump Bearing , Water Pump Pully , Wheel Bearing , Wheel Cap , Wheel Cylender Assly. , Wheel Cylender Boot , Wheel Cylender Brucket , Wheel Cylender Kit , Wheel Cylender Pipe , Wheel Cylender Piston , Wheel Drum , Wheel Hub Assly. , Wheel Oil Seal , Wheel Rim , Whel Axle Shaft /Axle Assly. , Wipper Arm & Blade , Wipper Machine Electronic Vaccum Type , Wipper Wheel Box , Wipper/Pennel Switch , Front Tyre , Rear Tyre , Bonnet Adjustment , Removing And Replacing Of Door Handle , Removing And Replacing Of Door Lock , Removing And Replacing Of Rear Back Light , Replacement Of Channel Set And Bidding Set , Replacement Of Door Bidding Set , Replacement Of Door Canned Set , Replacement Of Door Glass Each , Replacement Of Door Gola , Replacement Of Door Handle Set , Replacement Of Front And Rear Bumper , Replacement Of Front Wind Glass , Replacement Of Roof Upholstery , Replacing Door Hinges Pins Of Each Door , Replacing Door Window Regulator , Wheels & Tyres , Tata 407 , Ampere Meter , K.M (Speedo Meter) , K.M Cable , Oil Pressure Assembly , Temperature Meter , Bevel Pinion Set , C. Side Bearing Cap Bolt , Crown & Tail Pinion Assembly , Crown Case Bolt , Crown Side Adjustor , Crown Side Bearing , Diff. Cover Gasket , Diff. Gear Shaft , Differential Spider Cross , Driver Gear , Rear Axle , Spider Washer , Tail Pinion Bearing , Tail Pinion Adjs. Shim , Tail Pinion Coupling , Tail Pinion Nut , Tail Pinion Oil Seal , Bonnet Kapza , Bonnet Lock , Cabin Mounting , Clutch Fork Rod , Clutch Housing Gb. 30 , Clutch Housing Gb. 40 , D. Filter Catching Assembly , Dynamo Armature , Dynamo Bearing Big , Dynamo Bearing Small , Dynamo Carbon , Dynamo Field Coil , Dynamo Plate , Engine Mounting Bolt , Fly Weight Assembly , Handle , Head Bolt With Washer , Jack With Handle , M. Filter Catching Assembly , Oil Cooler Side Plate , Servo Repair Kit , F & R Shackle Bush , F & R Shackle Washer , F&R Shackle Pin , F&R U Bolt , Front & Rear C.Bolt , Front Aux. Leaf A&B , Front Eighth Leaf , Front Fifth Leaf , Front Fourth Leaf , Front Main Leaf , Front Second Leaf , Front Seventh Leaf , Front Sixth Leaf , Front Spring Assembly , Front Third Leaf , Rear Aux. Assembly , Rear Aux. Leaf F&R , Rear Eighth Leaf , Rear Fifth Leaf , Rear Fourth Leaf , Rear Main Leaf , Rear Ninth Leaf , Rear Second Leaf , Rear Seventh Leaf , Rear Sixth Leaf , Rear Third Leaf , A.C. Head , Air Cleaner Pipe , Air Cleaner Rubber , Brake Shoe Return Springs , Brake Shoe Rivits , Double Gear , F & R Hub Assembly , F & R Shock Absorber , F. Brake Shoe Tawa , F. Spindle Choak Nut , F. W.C Repair Kit , F. Wheel Bearing I , F. Wheel Bearing O , F. Wheel Brake Shoe , F. Wheel Cylinder Assembly , F. Wheel Oil Seal , Front Brake Drum , Front Spindle , Front Wheel Rim , Hub Wheel Bolt , King Pin Bearing , King Pin Bush , King Pin Set , King Pin Shim & Lock Kit , Nozzle Pipe Set , R.W.C. Bucket With Boot , Rear Wheel Brake Shoe , Shocker Bolt , Third Arm Bolt , Front Tyre , Rear Tyre , Bonnet Adjustment , Removing And Replacing Of Door Handle , Removing And Replacing Of Door Lock , Removing And Replacing Of Rear Back Light , Replacement Of Channel Set And Bidding Set , Replacement Of Door Bidding Set , Replacement Of Door Canned Set , Replacement Of Door Glass Each , Replacement Of Door Gola , Replacement Of Door Handle Set , Replacement Of Front And Rear Bumper , Replacement Of Front Wind Glass , Replacement Of Roof Upholstery , Replacing Door Hinges Pins Of Each Door , Replacing Door Window Regulator , Chillam , Chillam Oil , Counter Gear , Counter Washer Kit , First Gear , Fourth Gear , Gear Box Coupling , Gear Box Cover Kit , Gear Box Gasket , Gear Box Housing , Gear Box Mounting , Gear Box Oil Seal , Gear Box Top Cover , K.M Pinion , K.M Pinion Back Casing , Main Shaft Assembly , Main Shaft Bearing , Main Shaft Bearing special , Main Shaft Roller , Over Flow Valve , Second Gear , Servo Assembly , Synchronizer Assembly , Synchronizer Brass Ring , Synchronizer Lock Kit , Synchronizer Outer , Third Gear , Top Shaft Pilot Bearing , Top Shaft Ruler Bearing , Top Shaft Assembly , Top Shaft Bearing Outer , Top Shaft Check Nut, , Top Shaft Roller , A.C Cam Cutting , A.C. Block Boaring , A.C. Sleeve Fitting , Block Boaring , Block Bush Fitting , Block Facing , Block Line Boaring , Brake Drum Polishing , Cam Bush Fitting , Cam Polishing , Connecting Boaring , Connecting Bush Fitting , Crank Cutting , Fly Weight Tuning , Fuel Pump & Nozzle Overhauling With Materials , Head Facing , King Pin Overhauling , Oil Seal Brass Welding & Matching , Sleeve Fitting , Valve Guide Fitting , Valve Seat Fitting , Back Light Assembly , Back Light Glass , Brake Flexible Pipe , Brake Sdjuster , Brake Switch , completion Switch , Double Horn , Dynamo Cut Out , F.S Ind. Light Assembly , Flasher Unit , Fog Light Assembly , Fuse Box , H.L. Assembly , Head Light Holder , Headlight Bulb , Horn Cut Out , L.T. Wire - Roll , M.C Repair Kit , M.C.Assembly , Parking Light Bulb , Push Button Switch , Side Mirror , Starting Switch , Wiper Arm , Wiper Blade , Wiper Motor Assembly , Alternator Armature , Alternator Assembly. , Alternator Cut Out , Alternator Roc. Assembly , C, Bearing Without Oil Seal , C. Bearing Bracket , C. Bearing Rubber , Dynamo Rivits , Dynamo Pully , P. Shaft Cross Holder , P. Shaft Flange , P.Shaft Assembly Rear , P.Shaft Half Yoke , P.Shaft Yoke & Teeth , Propeller Shaft Assembly , Propellor Shaft Bolt , U.J. Cross , Self Armature , Self Assembly , Self Bendix , Self Bush , Self Carbon , Self Carbon Plate , Self Casing , Self Clutch Assembly , Self Field Coil , Self Flanger Bolt , Self Housing , Self Pinion , Self Point , Self Solenoid Switch , Steering Bearing , Steering Boot , Steering Box Assembly , Steering Bush , Steering Column Assembly , Steering Cone , Steering Coupling , Steering Cross Assembly , Steering Drug Link Assembly , Steering Gasket , Steering Sector Adj. , Steering Sector Assembly , Steering Sector Oil Seal , Steering Shaft With Bush , Tie Rod Controller Kit , Tie Rod End , Tie Rod End Clamp , A.C. Pump Assembly , A.S. Pump Repair Kit , Oil Pump Assembly , Oil Pump Gear , Oil Pump Repair Kit , Oil Releaf Valve , Radiator Assembly , Water Pump Assembly , Water Pump Bearing , Water Pump Gasket , Water Pump Impeller , Water Pump Repair Kit , Water Pump Seal Kit , Water Pump Shaft , A.C . Ring , A.C Bearing , A.C. Linner , A.C.Kit , A.C.Piston , Air Tank Assembly , Cam Shaft Bush , Champer Gasket , Clutch Plate Gb .30 , Clutch Plate Gb.40 , Clutch Release Bearing , Clutch Repair Kit , Connecting Bearing , Connecting Rod Assembly , Connecting Rod Bolt , Connecting Rod Bush , Crank Shaft P. Assembly , Crank Shaft P. Bearing , Diesel Filter , Diesel Flexible Pipe , Engine Gasket Unit , Engine Mounting , Engine Mounting Rear , Engine Valve (Exhaust) , Engine Valve (Inlot) , Fan Belt , Fly Wheel Bearing , Fly Wheel Ring , Head Gasket , Main Bearing , Main Bearing Colur , Main Bearing Oil Seal , Main Bearing T.Washer , Mobile Filter , Mobile Flexible Pipe , Piston A , Piston Ring , Piston Sleeve , Pressure Plate . Gb. 30 , Pressure Plate. Gb. 40 , Radiator Hose Pipe , Rocker Arm Bush , Rocker Arm Shaft , Silencer Pipe Front , Silencer Gasket , Silencer Muffler , Silencer Pipe Rear , Tappit Cover Gasket , Third Gear Fork , Timing Cover Gasket , Timing Cover Oil Seal , Valve Guide , Wheels & Tyres , Tata Ace , Fitting Of Ac In The Car , Gas Filling , General Servicing Of Ac , Removal Of Ac From The Car , Bonnet Adjustment , Removing And Replacing Of Door Handle , Removing And Replacing Of Door Lock , Removing And Replacing Of Rear Back Light , Replacement Of Channel Set And Bidding Set , Replacement Of Door Bidding Set , Replacement Of Door Canned Set , Replacement Of Door Glass Each , Replacement Of Door Gola , Replacement Of Door Handle Set , Replacement Of Front And Rear Bumper , Replacement Of Front Wind Glass , Replacement Of Roof Upholstery , Replacing Door Hinges Pins Of Each Door , Replacing Door Window Regulator , Adjustment Of Brake Bleeding System , Adjustment Of Foot Brake Shoe , Bearing And Adjustment , Overhauling Of All The Wheel Cylinder , Overhauling Of Complete Brake Dsysterm , Overhauling Of Master Cylinder , Replacement Of Complete Break Linings , Replacement Of Break Drum Front , Replacement Of Break Drum Linings , Replacement Of Break Shoe And Blooding , Replacement Of Front Brake Linings , Replacement Of Front Break Drum , Replacement Of Hand Break Cable , Replacement Of Rear Brake Linings , Replacement Of Wheel Cylinder ( One Side ) , Adjustment Of Free Travel Of Clutch , Clutch Overhauling , Overhauling Of Clutch Plate Assembly , Replacement Of Clutch Adjusting Rods , Replacement Of Clutch And Brakes Pedal Shafts/Bushes , Replacement Of Clutch Plates , Dynamo , Dynamo Assembly Replacement , Fitting Of New Electric Bulb In Parallel , Fitting Of New Search Light , Fitting Of Speedometer Cale Assembly , Head Light Focusing , Oberhauling Of Self Starter , Overhauling Of Horn Ring , Overhauling Of Wiper Moter , Repairing Of Horn , Replacement Of Dynamo Fan , Replacement Of Dynamo Pulley , Replacement Of Horn Ring Starter Place Sleeve , Replacement Of Ignition Switch , Replacement/Check-Up Of Fuel Guage Dashboard , Replacemnt And Check-Up Of Wiper Blade , Replacemnt Of Armature , Replacemnt Of Complete Wiring , Replacemnt Of Dashboard Light Bulb , Replacemnt Of Fuel Guage Tank Unit , Replacemnt Of Head Bulb Each , Replacemnt Of Self Starter Switch , Replacemnt Of Side And Tail Light Bulb , Replacemnt Of Solenoid Switch , Replacemnt Of Voltage Regulator , Replacent Of Wiper Moter , Testing And Recharging Of Battery , Adjustment And Refitting Of Oil Pressure Relief , Adjustment Of Tappet , Change Of Flywheel Ring , Claening And Replacemt Of Spark Plug , Claening Of Carburator , Cleaning Of Distribute , Cleaning Of Distributer Cap , Cylinder Head Overhauling , Engine Timimg Tappet Adjustment, Distributer And G.R.Point, Spark Plugs Cleaning And Adjustment , Overhauling Of Fuel Pump , Overhauling Of Water Pump Assembly , Overhauling Of Water Pump Bearings , Overhouling Of Complete Engine , Refitting Of Connecting Rod Bearing , Refitting Of Oil Pump , Replacement Of Accelerator Wire , Replacement Of Timing Coverplace , Replacement Of Vaulve Guide , Replacemnt Of Fan Belt , Replacemnt Of New Timing Chain , Replacemnt Of Timimng Covers Packing , Replacemt Of Main Bearing , Rocher Shaft And Tappet Replacement , Exhaust , Realigning Exhaust Pipe Assembly , Replacement Of Exhaust Pipe Front , Replacement Of Muffler Assembly, Buffer Plate , Replacement Of New Muffler , Replacement Of Silencer Pipe ( Each ) , Replacement Of Tail Plate , Remove Cleand And Refitt Fuel Tank , Replace Fuel Tank Hose Pipe , Replace Petrol Flexible Pipe Each , Replace Petrol Tank Hard Board Cover , Overhauling Of Gear Box , Overhauling Of Gear Box Assembly , Replacement Of Front Oil Seal , Replacement Of Gear Box Foundation , Replacement Of Gear Lever , Replacement Of Gear Linkage Ball Joint , Replacement Of Side Dash Cover Packing And Seal , Complete Painting After Scrapping Old Paint , Complete Painting Color Change , Complete Painting Double Coat Without Dent , Complete Painting Single Coat Without Dent , Fitting Of New Propeller Shaft , Fitting Of New Propeller Shaft U Point , Overhauling Of Differential,Dismantlingof Rear Axle Fitting With New Charts , Refitting Of Rear Axle Assembly Including Bending And Adjusting Brakes , Replacement Of Back Plate Assembly From The Axle Casing Flange , Replacement Of Differential Packing , Replacement Of Hub Bearing , Replacement Of Hub Oil Seal , Replacement Of Pinion Oil Seal , Replacement Of Rear Axle Shaft , Replacement Of Rear Brake Drum , Adjustment Of Ball Joint , Adjustment Of Damper Pad , Adjustment Of Flang , Adjustment Of Pinion Bearing , Adjustment Of Pinion Thrust , Adjustment Of Tie Rod Ends , Adjustment Of Toe-In And Toe-Out , Overhauling Of Cpmplete Steering , Removal Of Refitting Of Steering Assembly , Replacement Of Ball Joint (Each) , Replacement Of Bottom Melt Of Steering Wheel , Replacement Of Bracket Column Sipport Asssembly , Replacement Of Gear Control Rod , Replacement Of Gear Control Rod Assembly , Replacement Of Gear Control Rod Support Pivot Pin Selector Lever New Making , Replacement Of Gear Pivot Breakings , Replacement Of Steering Column , Replacement Of Steering Wheel , Replacement Of Tie Rod Ends , Replacement Of Top Melt Of Steering Wheel , Setting Of Wheel Castor Chamber And Toe-In-Out , Overhauling Of Complete Suspension , Replacement Of Broken Leaf , Replacement Of Front Bush Suspension , Replacement Of Front Wheel Oil Seal , Replacement Of One Shoch Absorber , Replacement Of Rear Spring Assembly , Replacement Of Rear Spring Bushes , Replacement Of Rubber Bush Kit , Replacement Of Tie Bar Bush (One Side ) , Replacement Of Torsion Bar , Front Tyre , Rear Tyre , Dry Servicing And Lubrication , Engine Tuning , Greasing The Vehicle , Replacing Oil-Filter And Engine-Oil Change , Rubbing And Policing The Vehicle , Servicing And Lubrication, Replacing Oil-Filter Element , Washing , Wheels & Tyres , Tractor , Actuating Lug Assy. , Bracket , Dowel Pin , Fixed Gear , Fork Assy , Propeller Shaft Cover , Sliding Gear , Universal Joint Assy. , Canopy , Dry Air Cleaner Assy. , Filter Cartridge Dry Air Cleaner , Gasket Inlet Cover Assy. , Hose Clamp , Hose Clip , Pipe Inlet , Clutch Housing , Clutch Plate , Copper Washer , Inner Bush , Metalic Bush , Shaft Assy. , Single Cluth Assy. With Clutch Plate , Spring Dowel Sleeve , Control Valve Assy. , Kit Camshaft , Kit Position Lever , Kit Quadrant With Friction , Anti Freeze Coolant , Ctb Clamp , Hose Clip , Hose Pipe , No Loss Tank , Radiator Assy , Radiator Hose , Bushing Cam Shaft , Bushing Knock , Cap Set Bearing , Case Oil Seal , Crankcase Assy , Gasket Oil Seal Case , Gasket Plate Front , Main Bearing Set , Oil Filter , Pin Dowel , Plate Front , Plug Expanision , Rear Plate , Side Seal , Connecting Rod Assy , Crankshaft Gear , Crankshaft Nut , Flywheel Bolt , Piston , Plane Washer , Pulley Engine , Ring Gear Fly Wheel , Ring Sets Piston , Cap Sealing , Cap Valve Stem , Cylinder Head Assy , Gesket Cylinder Head , Guide Exhaust Valve , Hose Clamp , Hose Pipe , Jet Combustion , Plate Connector , Retainer Valve Stem , Seal Valve Stem , Seat Exhaust Valave , Seat Inlet Valve , Spring Valve , Spring Washer , Tappet , Thermostat Housing , Valve Exhaust , Valve Inlet , Valve Lock Spring , B.P. Shaft , Cage Carrier , Pedal Assy. , Sleeve , Battert Cut-Off Switch Mtg Plate , Battery , Beacon Lamp , Beacon Wiring Harness , Combination Switch , Fender Lamp , Flasher Unit Assy. , Hazard Switch , Head Lamp Assy , Holder Rod , Horn Assy (High Tone) , Horn Mounting Bracket , Instrument Cluster , Main Wiring Harness , Oil Pressure Sensor , Relay , Socket Assy. , Starter Switch Assy. , Stop Switch , Alternator Assy , Engine Assy. , Engine Oil , Plate Adjusting , Spacer Alternator , Starter Motor , Gasket Silencer , Manifold Exhaust , Nail Rivet , Round Silencer , Steering Cylinder , Pivot Pin Assy. , Thrust Washer , Bevel Pinion Shaft , Crown Wheel & Tail Pinion , Locking Washer(Crown Wheel) , Washer Bevel Pinion , Tail Pinion Carrier , Assy. Trumpet Housing Front , Gear Oil , Trumpet Housing , Assy Steering Arm , Assy. Front Axle Housing , Bearing , Bevel Gear , Front Axle , Gasket Steering Arm , Steering Arm , Stub Axle , Clip. Hose , Fuel Feed Pump , Fuel Filter Assy. , Fuel Pipe , High Pressure Pipe , Hose Clip , Hose Fuel , Injector Over Flow Pipe , Joint Three Way , Nozzle & Holder Assy. , Strainer Plus Pipe Assy. , Ext. Circlip , Halical Gear , Intermediate Shaft , Lay Shaft , Needle Bush , Oil Seal , Tapper Roller Brg , Conical Spring , Dipstick , Gear Shifter , Lever Assy , ORing , Pin Assy. , Rubber Boot , Spring , Z-Plate , Bolt Governor Case , Bolt. High Speed Set , Case Governor , Cover Torque Set , C-Ring Torque , Gasket Governor Case , Lever Governor , Lever Speed Control , Nut Torque Set , Pin Spring , Screw Assy. Back Set , Shaft Governor , Shaft Sliding Sleeve , Shim. Governor Shaft , Sleeve Sliding , Solenoid Assy. , Spring Governor , Spring Start , Spring Tie Rod , Washer Spring , Weight Assy. Governor , Encl. In Seat Kit , External Circlip , Kit Crank , Kit Cylinder , Kit Piston , Shaft , Hydraulic Lift Assy. , Lever , Kit Relief Valve , Lift Body Assy , Lub Oil Filter , Oil Pump Assy. , Strainer Assy. Oil , Switch Oil Pressure , Valve Assy. Relief , Drain Plug , Brake Pedal , Clutch Pedal Assy. , Hinge Pin , Knob Assy- Parking Brake , Link Pin , Tie Rod Assy , Draft Lever , Knob Assy. - Operating Sector , Knob Lever , Position Lever , Clamp , Gear Pump , Hsu Pipe , Nipple , O-Ring , Reduction Hose , Steering Column Assy. , Suction Pipe , Suction Strainer , Trolly Pipe , Ball Brg , Cover (Pto Shaft) , Pto Gear , Pto Lever Assy. , Pto Shaft , Pto Sliding Gear , Air Valve Assy , Industrial Tyre , Rear Axle , Rim Rear , Spacer , Turf Tyre , Wheel Rim , Wheel Tyre , Front Tyre , Rear Tyre , Axle ( Foot Throttel ) Assy. , Bonnet Assy. , Dashboard Assy. , Fender Assy , Foot Board Assy , Foot Throttle Assy , Fuel Tank , Hand Accelerator Assy , Head Light Frame , Meter Plate , Mounting Strip , Mtg Pin , Push Rod Assy. , Rear View Mirror , Reflex Reflector , Side Cover -Radiator , Spring Cotter , Strap Clamp , Tail Lamp Bkt. Assy , Dome Sticker Round , Front Wheel Rim , Rim Front , Steering Wheel , Tyre (Rear & Front) , Adjustable Ancher Chain , Back Plate Rops (For 1026E) , Bush Plate Assy. , Draw Bar Assy. , Hook Pin , Linch Pin Assy , Lower Link Assy. (Lh&Rh) , Pin-Lift Rod , Pin-Top Link Assy. , Shaft Lower Link Assy. , Bolt Rocker Bracket , Bracket Rocker Shaft , Bush Idler Gear , Camshaft , Cap Oil Filler , External Circlip A-19 , Gasket Cover Assy. , Gear Assy. Idler , Gear Camshaft , Gear Fip , Rocker Assy. , Shaft Assy. Rocker , Spring Rocker , Bearing Hsg. , Gasket , Fan Belt(B-37) , Fan Cooling , Fan Spacer , Gasket Water Pump , Plate Water Pump , Pulley Water Pump , Water Pump Assy. , Actuator Assy. , Brake Lever-Parking Brake , Cover -Brake Housing , Friction Disc , Gasket Brake Housing , Gear Oil Wet Brake , Steel Disc , Swiel Block , Wet Brake , Wheels & Tyres , Tractor Trolly , Wheels & Tyres , Chasis/Frame , Trolley Body , Axle & Hub Assembaly , Hydraulic Jack/Sylinder , Toing Channel/Drawbar , Braking System , Tailgate , Lights , Reflectors , Stablizer Jack , Cuplink , Velding Work , Painting Work , Other Fabrication/Repair Work , Water Tanker Supply , Battery , Charger 51.2V/100Ah , Charging Socket Set , Hydrolic & Compressor Repairing , Controller (1000 Watt) , Convertor , Full Electrical Wiring , Drl Led Head Light , Back Horn , Indicator Bulb Front , Indicator Bulb Back , Key Lock , Motor (1000 Watt) , Paint , Accelerator Mutha , lane road Mutha , Body Repairing/Velding Work , Speedometer , Flasher , Hydraulic Set With Remote , Labour Charges , Water Supply Tanker , Wheels & Tyres , Chasis/Frame , Trolley Body , Axle & Hub Assembaly , Hydraulic Jack/Sylinder , Toing Channel/Drawbar , Braking System , Tailgate , Lights , Reflectors , Stablizer Jack , Cuplink , Velding Work , Painting Work , Other Fabrication/Repair Work
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
42.
Coal and Mines #10889672 AOC
Bids Are invited for Fore Court Controller Fcc - Forecourt Controller Integrates With Flow Meter And Mobile Dispensing Unit, Integrates With Rfid Tags And Container Rings With All Configurations Of Rfid Readers Including Nozzle Reader, In-Built Battery Backup Of 15 Minutes, Mounted Inside The Mobile Bowser Simple Enclosure. The Enclosure Should Be Rugged To Prevent The Effects Of Vibration Of The Vehicle Movement From Adversely Affecting The Functioning Of The Electronics And Connected Devices. , Wireless Gateway Terminal - Type-Rf And Safe Area Mounted. Communication Between Nozzle Reader And Rfid Controller-Iec By Iso Compliant. Installation-Should Be Installed In Such A Way That All Nozzle Readers Are Able To Communicate With The Same Wireless Equipment. Should Be Stable Operation In Noisy Or Busy Environment. Data Security-The Wireless Communication Should Been Crypted Using Aes 128Bit. Should Communicate With Fcc. Operating Voltage-Suitable To Operate With Ac Power Available At The Ro. Ip Rating-Ip54. Remote Diagnostics-Should Be Accessed Over Web For Diagnostics, Trouble Shooting And Upgrade Task E.G, Software Upgrade, Battery Check, Communication Check Etc. Communication Channels-Should Employ Multiple Channel Frequency Networks To Enable Fast Switching Of The Channels To Ensure Uninterrupted Communication With Station Automation System. Rf Frequency Bands To Meet Regional Frequency Allocation Regulations. , Industrial Router - Router Cum Modem To Support All Gsm Communication Network Available In India Including Having Features Of Volte Compatibility. In Case Of No Communication, Router Should Have Inbuilt Intelligence To Continuously Ping Mcl Server Without Going To Sleep Mode , Rfid Nozzle Reader Peso Approved - Type-Rf. Communication Between Rf Vehicle Tag And Nozzle Reader-Iec By Iso Compliant By Lf. Communication Between Nozzle Reader And Rfid Controller-Iec By Iso Compliant By Ieee. Security-Once Mounted On The Nozzle And Activated, It Should Be Deacti
Contract Date: Ref. Documents Contract Value : 10.86 Lakh
Boards / Undertakings / PSU No of Bidders 1
44.
Housing Urban and Rular Development #10825239 Price Bid
Provision For Replacement Of Old-Damaged Unserviceable Ac Units In Transport Authority 5-9 , Under Hill Road , Civil Lines , New Delhi-54 , Supplying & Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb C Curve Including Connections , Painting Etc . As Reqd . , Sitc Of Invertor Type Stac Unit Complete Indoor & Outdoor With Outdoor Stand Dully Powder Coated Of Following Capacity Suitable For Operation On 220V + 10% Single Phase 50 Hz Hv Ac Supply Complete With Energy Efficient Rotary Compressor Type Of Refrigerant R32 / 410 , 100% Copper Condenser Coil Complete In All Respect & With Cordless Remote , Refrigerant Copper Pipings & Five Core Flexible Copper Wire Of Suitable Rating / Size & Pvc Drain Piping Each Upto 5 Mtr Length I / C Connection Etc , As Reqd . ( Make:-Diakin / Ogenral / Mitsubushi Heavy Industries / Hitachi / Voltas / Bluestar ) A ) 1 . 5 Tr 5-Star Inverter Split Ac Unit , 2 / 2 . 2 Tr 5-Star Inverter Split Ac Unit , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor , Single Core Cable In Surface / Recessed Steel Conduit As Required . A ) 2 X 4 Sq . Mm + 1 X 4 Sq . Mm Earth Wire , B ) 2 X 6 Sq . Mm + 1 X 6 Sq . Mm Earth Wire , Supplying And Fixing Of Following Ways Surface / Recess Mounting , Vertical Type , 415 V , Tpn Mcb Distribution Board Of Sheet Steel , Dust Protected , Duly Powder Painted , Inclusive Of 200 A Tinned Copper Bus Bar , Common Neutral Link , Earth Bar , Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required . ) A ) 12 Way ( 4 + 36 ) , Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating , 240 Volts , C Series , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . A ) Single Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel , Making Connections , Etc . As Required . I ) 100 A , 16 Ka , Tpmccb , Dismantled Of Old Existing Ac I / C Buy Back The Same Old / Burnt Out Ac From Vrs Site I / C Making Good The Damage Etc As Reqd .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 12
45.
Educational and Research Institute #10815224 Price Bid
Procurement, Installation And Maintenance Of Infrastructure And Communication Technology (Ict) Equipment And Consumables Procurement, Installation And Maintenance Of Infrastructure And Communication Technology (Ict) Equipment And Consumablesprabodhini College, Porvorim, Goa. , Category 2: Ict Equipment’S Estimated Cost:59,88,000 /- , Digital Metal Podium Powder-Coated Metal Cabinet, Free-Standing, With Lockable Caster Wheels For Mobility; Crca Steel ~1.6 Mm Thick; Metal Top; Locking Security System; Storage Space For Cpu, Keyboard & Mouse, Laptop Trays, Side Shelf, 21.5? Interactive Touch Monitor; Motorised Tiltable Monitor Mechanism; Scratch-Resistant, Anti-Glare Screen; Full Hd (1920×1080) Resolution; Supports Finger & Stylus Input; Annotation Software Capabilities, Built-In 120 W Rms Amplifier; Two 30 W Wall Speakers; Two Gooseneck Microphones; One Wireless Handheld Mic; One Wireless Collar Mic; The Usual Av Input/Output (Vga, Hdmi, Usb, Aux, Xlr, Etc., Cpu: Intel I5; Ram 8 Gb; Storage: 500Gb Hdd; Wifi And Bluetooth; Includes Keyboard & Mouse., Vga, Hdmi, Usb, Aux, Xlr; Rj-45 Lan Port; Vga/Hdmi Switcher; Front Panel “Source” Control; Power Sockets Etc., Dimensions: 28? X 22? X 47? (L × W × H) ; Weight ~ 80 Kg, Minimum 1 Year Warranty , Smartboards Preffered Make:Viewsonic/Samsung/Solitaire Panel Size: 75,Type/Tech: Ips Type,Display Area (Mm): Minimum 1650.24(H) × 928.26(V),Aspect Ratio: 16:9,Native Resolution: 4K60hz,Colours: 10 Bits,Brightness: Minimum 450 Nits Or Higher,Contrast Ratio: 1200:1 (Typ) 5000:1 (Dcr) Or More,Response Time: 8Ms Or Better,Viewing Angles: H = 178, V = 178 Typ.,Backlight Life: Minimum 50,000Hr Of Higher Surface Treatment: Hardness: 9H Or Higher,Thickness: 4Mm,Orientation: Landscape,Processor: Octa Core Arm Cortex-A73*4 + A53 * 4 Or Higher,Android 11.0 And Upgarade To 13,Ram: 8Gb Ddr4 Or More,Storage: 64Gb Or More Type/ Tech: Ir Recognition/ P-Cap,Touch Point: 40 Points Or Higher,Hdmi In: Minimum 3,Rs232: X1,Ops: 1 Audio Out: 3.5Mm X1,Spdif: X1, Rj45: X2,Type A: Usb 2.0 X2, Usb 3.0 X4 “Smartport Usb” To All Channels,Type B: X2, For Touch,Type C: X1 (Dp 1.2, Usb2.0, Pd65w, Ethernet 100M),Speakers: 12W X 2 + 16W X 1 Or More Light Sensor : Yes,Power Consumption: 140W Or Less,Eye Care Certification Like Low Blue Light & Flicker Free Certifications: Tuv, Fcc, Energy Star 8, Emc/Ce, Cb, Rohs & Doc, Reach Test Report, Weee Test Report, Bis, Epat Software Features: Entity Management & Device Manager To Manage Ifp Remotely Without Lan, Also To Share Content & Broadcast Messages Remotely Onto Ifps,Same Whiteboard Software For Windows, Android & Browser,Live Webcast Directly From Interactive Whiteboard Software To Youtube And Facebook, Screen Recording,Artificial Intelligence Pen,Wireless Casting On Ifp From Mobile & Laptop,Drag And Drop Youtube Videos, Direct Images From Google Search,Handwriting Recognition Text To Speech Inbuilt In Whiteboard Software (Male Or Female Voice),Create Online Quiz With Time Limit From Whiteboard Software,Auto Grading Of Answers,Download Results As Excel Sheets,Sign In Directly From Qr Code On Interactive Whiteboard Software And Link Cloud Storages (Google Drive, Microsoft One Drive, Box Or Drop Box),4K Ops Module With Intel Core I5 Or Better, 8 Th Generation Or Better, 8 Gb Ram 256Gb Ssd Or Better. Ops Secification: 4K Ops Module With Intel Core I5 Or Better, 8 Th Generation Or Better, 8 Gb Ram 256Gb Ssd Or Better. Additional: Latest Microsoft Office And Ups , Video Conferencing Equipment- Webcamera Along With Wireless Speaker And Bluetooth Dongle Microphones For Large Classroom Setup- Evota Ultra-Wide 4K Resolution Camera For High-Definition Video Capture, Hd Support, Built In Microphone, And Microphone Wireless Speaker Phone With Bluetooth Dongle, Speaker Output, Ai Noise Reduction, 8 Mic Array, Built In Dsp,High-Quality Audio Output Suitable For Conference Or Meeting Rooms,Plug-And-Play Support , Camera And Lens- Preffered Make:Canon, Nikon Sensor: 24.2Mp Full-Frame Cmos Sensor,Processor: Digic X,Iso Range: 100–102,400 (Expandable To 50–204,800) Autofocus: Dual Pixel Cmos Af Ii With Up To 1,053 Af Points,Continuous Shooting: Up To 40 Fps With Electronic Shutter,Viewfinder: 2.36M-Dot Oled Evf,Display: 3.0 Vari-Angle Touchscreen Lcd With 1.62M Dots,Video: 4K Uhd At 60P, 10-Bit 4:2:2, Connectivity: Wi-Fi, Bluetooth, Uvc/Uac For Webcam Use Lens Format: Full-Frame,Focal Length: 24–105Mm,Aperture: F/4–7.1,Image Stabilization: Up To 5 Stops,Autofocus: Stm Stepping Motor For Smooth And Quiet Focusing,Macro Capabilities: Center Focus Macro With 0.5X Magnification,Minimum Focusing Distance: 0.66 Ft (0.20 M) In Autofocus; 0.43 Ft (0.13 M) In Macro Mode,Filter Size: 67 Mm , Dual-Channel Wireless Microphone System System Type: Dual-Channel Wireless Microphone System With One Receiver And Two Transmitters. Microphone Type: Built-In Omnidirectional Microphones In Each Transmitter; Supports External Lavalier Microphones Via 3.5Mm Trs Input. Transmission Technology: Series Iv 2.4Ghz Digital Transmission With 128-Bit Encryption. Transmission Range: Up To 200 Meters (Line Of Sight). Frequency Response: 50Hz – 20Khz. Maximum Spl: 100 Db Spl (1Khz @ 1M). Battery Life: Up To 7 Hours On A Full Charge. Charging Port: Usb Type-C. , Wireless Connectivity- Wifi Routers Wifi Routers- Tplink Archer C6 Dual Band Router,Dual-Band Wi-Fi: Supports Both 2.4 Ghz And 5 Ghz Frequencies , All In One Pcs Preffered Make: Hp / Dell /Lenovo I5- 13Th Gen 1355U Or Above,8 Gb ,512 Gb ,23.8 Diagonal, Fhd (1920 X 1080), Ips, Anti-Glare, Wled-Backlit, 250 Nits, 72% Ntsc,Win 11 Pro,Intel® Uhd Graphics; Intel® Iris® X? Graphics; Intel® Graphics,Wired,Microsoft Office 21 Or Above 3 -Years , Video Camcorder- Preffered Make:Canon, Sony 4K Uhd Recording,1/2.3 Cmos Sensor,Digic Dv 6,Mp4 And Xf-Avc (Mxf),4K Uhd (3840 X 2160) At Up To 30 Fps,Full Hd 1080P At Up To 60 Fpsuhd 4K Camcorder, Xf-Avc: Up To 160 Mbps,Mp4: Up To 150 Mbps,Iso/Gain: 0 To 24 Db,F/1.8 To F/2.8,Up To 800X,5-Axis Dynamic Is (Optical + Digital),2 X Xlr Terminals (With Phantom Power),3.5Mm Stereo Mini-Jack,16-Bit/48Khz Linear Pcm And Aac,Headphone Output, Lcd Screen,Touchscreen, Usb-C: Supports Uvc For Livestreaming,Hdmi Output: Mini-Hdmi 2.0, Recording Media: Dual Sd/Sdhc/Sdxc Uhs-I Slotsheavy Duty Tripod Stand For Video Camera , Drone- Weight: < 249 G Flight Time: Min 34–45 Minutes Camera: 1/1.3 Cmos, 48 Mp, 24 Mm F/1.7 Lens Video: 4K Up To 100 Fps, 1080P Slow-Motion Up To 200 Fps, 150 Mbps Bitrate Photo Formats: Jpeg, Raw (Dng) | Video Formats: Mp4, H.264/H.265, Supports Vertical Video Capture, Panorama Modes: Sphere, 180°, Wide Angle, Vertical, Remote Controller- 5.5-Inch Fhd Screen With A Resolution Of 1920×1080 Pixels, 60Hz Refresh Rate, And 700 Nits Brightness. Supports 10-Point Multi-Touch,Up To 1080P/60Fps Live Feed When The Aircraft Is In Photo Or Video Mode,4 Antennas, 2T4r (Two Transmitters, Four Receivers), Two Built-In Antennas And Two External Antennas With Manual Angle Adjustments For Optimal Video Transmission,Supports Quick Charging , Copier Machine: Preffered Make: Canon, Xerox, Ricoh Main Unit -Machine Type-A3 Monochrome Laser Multifunctional; Core Functions-Print, Copy, Scan, Send And Optional Fax; Processor Speed 1.6Ghz Dual Core Processor; Control Panel Standard: 7 Inch Tft Lcd Wvga Colour Touch Panel; Memory Standard: 2.0Gb Ram; Storage Standard: 64Gb Emmc,Optional: 256Gb Ssd; Interface Connection- Network Standard: 1000Base-T/100Base-Tx/10-Base-T, Wireless Lan (Ieee 802.11 B/G/N), Wi-Fi Direct Connection Others Standard: Usb 2.0 (Host) X2, Usb 2.0 (Device) X1; Paper Input (Standard); Paper Supply Capacity (A4, 80 Gsm)-Standard: 1,200 Sheets Maximum: 2,300 Sheets (With Cassette Feeding Unit-Aw1); Paper Output Capacity (A4, 80 Gsm)-Standard: 250 Sheets Maximum: 645 Sheets (With Inner Finisher-L1 And Copy Tray-T2); Finishing Capabilities -Collate, Group, Offset, Staple, Hole Punch, Eco Staple, Staple On Demand; Supported Media Types- Main Body Cassette (Upper/Lower): Thin, Plain, Recycled, Color, Heavy, Bond, Pre-Punched, Letterhead, Postcard Multi-Purpose Tray:Thin, Plain, Recycled, Color, Heavy2, Bond, Pre-Punched, Letterhead, Postcard, Labels, Coated, Tracing;Supported Media Sizes-Upper Cassette: Standard Size: A4, A5, A5r, A6r, B5custom Size: 105.0 X 148.0 Mm To 297.0 X 215.9 Mm Lower Cassette: Standard Size: A3, A4, A4r, A5, A5r, A6r, B4, B5, B5r, Com 10 No. 10*, Monarch*, Dl* Custom Size: 105 X 148 Mm To 304.8 X 457.2 Mm; Supported Media Weights -Main Body Cassette (Upper/Lower): 52 To 256 Gsm Multi-Purpose Tray: 52 To 300 Gsm Duplex: 52 To 220 Gsm; Warm-Up Time -4 Seconds Or Less From Sleep Mode: 10 Seconds Or Less From Power On: 10 Seconds Or Less; Dimensions (W X D X H)- 565 X 687 X 891 Mm; Installation Space (W X D)-1,286 X 1,116 Mm (With Dadf-Ba1 + Inner Finisher Tray Max Extended + Copy Tray-T2 Max Extended + Paper Cassette Opened; Weight -Approx. 66 Kg Print Specifications-Print Speed:Up To 45 Ppm (A4, A5, A5r, A6r), Up To 22 Ppm (A3), Up To 32 Ppm (A4r),Print Resolution (Dpi):Up To 1200 X 1200;Page Description Languages;Standard: Ufrii, Pcl6, Optional: Adobe Postscript 3Tm; Double-Sided Printing: Yes; Direct Print: Pdf, Eps, Tiff/Jpeg, Xps; Mobile / Cloud Printing: Airprint, Mopria, Canon Print Business, Uniflow Online And Universal Print By Microsoft; Fonts : Ps Fonts: 136 Roman Pcl Fonts: 93 Roman, 10 Bitmap Fonts, 2 Ocr Fonts, Andalé Mono Wt J/K/S/T (Japanese, Korean, Simplified And Traditional Chinese) , Barcode Fonts Print Features: Secure Print, Secure Watermark, Header/Footer, Page Layout, Duplex Printing, Mixed Paper Sizes/ Orientations, Toner Reduction, Poster Printing, Forced Hold Printing, Print Date, Scheduled Printing, Printing Using A Virtual Printer Operating Systems :Ufrii: Windows 10/11/Server2012/Server2012 R2/Server2016/Server2019/Server2022, Mac Os X (10.13 Or Later) Pcl: Windows 10/11/Server2012/Server2012 R2/Server2016/Server2019/Server2022 Ps: Windows 10/11/Server2012/Server2012 R2/Server2016/Server2019/Server2022, Mac Os X (10.13 Or Later) Ppd: Windows 10/11, Mac Os X (10.13 Or Later) Copy Specifications :Copy Speed Up To 45 Ppm (A4, A5, A5r, A6r), Up To 22 Ppm (A3), Up To 32 Ppm (A4r),First-Copy-Out Time:5.3 Seconds; Copy Resolution (Dpi):600 X 600; Multiple Copies: Up To 999 Copies; Copy Density: Automatic Or Manual (9 Levels); Magnification:25% - 400% (1% Increments); Preset Reductions: 25%, 50%, 70%, 100% (1:1), 141%, 200%, 400%; Preset Enlargements:25%, 50%, 70%, 100% (1:1), 141%, 200%, 400%; Basic Copy Features: Preset R/E Ratios By Area, Two-Sided, Density Adjustment, Original Type Selection, Interrupt Mode, Book To Two Pages, Two-Sided Original, Sort, Job Build, N On 1, Different Size Originals, Sharpness, Erase Frame, Copy Id Card, Skip Blank Pages, Free Size Original, Color Mode, Reserved Copy, Copy Sample; Scan Specifications:Type: Color Scanner; Pull Scan Specifications: Colour Network Scangear2. For Both Twain And Wia Supported Os: Windows 10/11/Server2012/Server2012 R2/Server 2016/Server 2019/Server2022; Scan Resolution (Dpi): Scan For Copy: 600 X 600 Scan For Send: (Push) 600 X 600 (Smb/Ftp/Webdav/Ifax), (Pull) 600 X 600 Scan For Fax: 600 X 600; Document Feeder Paper Capacity (80 Gsm): Up To 100 Sheets; Acceptable Originals/Weights: Platen: Sheet, Book, 3-Dimensional Objects Document Feeder Sheet Media Weight : 1-Sided Scanning: 38 To 128 Gsm (Bw), 64 To 128 Gsm (Cl) 2-Sided Scanning: 50 To 128 Gsm (Bw), 64 To 128 Gsm (Cl); Supported Media Sizes: Platen: Max. Scanning Size: 297.0 X 431.8 Mm Dadf: A3, A4, A4r, A5, A5r, B4, B5, B5r, B6, Custom Size: 139.7 X 128.0 Mm To 297.0 X 431.8 Mm; Scan Method:Push Scan, Pull Scan, Scan To Network, Scan To Usb Memory Key, Scan To Mobile Device, Scan To Cloud-Based Services (Uniflow Online); Scan Speed:1-Sided Scanning: 70/70 (300 X 300 Dpi, Send), 51 /51 (600 X 600 Dpi, Copy) 2-Sided Scanning: 35/35 (300 X 300 Dpi, Send), 25.5 /25.5 (600 X 600 Dpi, Copy); Double-Sided Scanning: Yes;Supported Media Sizes: Platen: Max. Scanning Size: 297.0 X 431.8 Mm Dadf: A3, A4, A4r, A5, A5r, B4, B5, B5r, B6, Custom Size: 139.7 X 128.0 Mm To 297.0 X 431.8 Mm; Scan Method:Push Scan, Pull Scan, Scan To Network, Scan To Usb Memory Key, Scan To Mobile Device, Scan To Cloud-Based Services (Uniflow Online); Scan Speed:1-Sided Scanning: 70/70 (300 X 300 Dpi, Send), 51 /51 (600 X 600 Dpi, Copy) 2-Sided Scanning: 35/35 (300 X 300 Dpi, Send), 25.5 /25.5 (600 X 600 Dpi, Copy); Double-Sided Scanning: Yes; Send Specifications- Optional / Standard-Destination: Standard: E-Mail/Internet Fax (Smtp), Smb3.1.1, Ftp, Webdav,Optional: Super G3 Fax;Address Book / Speed Dials: Ldap (2,000)/ Local (1,600) /Speed Dial (200); Send Resolution (Dpi):Push: Up To 600 X 600 Pull: Up To 600 X 600; Communication Protocol: Ftp (Tcp/Ip), Smb3.1.1 (Tcp/Ip), Webdav Email/Ifax: Smtp(Send), Pop3(Receive); File Format: Standard: Tiff (Mmr), Jpeg Pdf (Compact, Searchable, Pdf/A-1B, Encrypted), Xps(Compact, Searchable), Pdf/Xps (Device Signature, Office Open Xml (Powerpoint, Word) Optional: Pdf (Trace & Smooth), Pdf/Xps (User Signature); Universal Send Features:Original Type Selection, Two-Sided Original, Book To Two Pages, Different-Size Originals, Density Adjustment, Sharpness, Erase Frame, Job Build, Delayed Send, Preview, Job Done Notice, File Name, Subject/Message, Reply-To, E-Mail Priority, Tx Report, Original Content Orientation; Fax Specifications- Optional; Modem Speed: Super G3: 33.6 Kbps G3: 14.4 Kbps; Compression Method: Mh, Mr, Mmr, Jbig; Resolution (Dpi):200X100dpi (Standard), 200X200dpi (Fine), 200X400 Dpi (Super Fine), 400X400 Dpi (Ultra Fine); Sending/Receiving Size: Sending: A3, A4, A4r, A5*1, A5r*1, B4, B5*2, B5r*1 Receiving: A3, A4, A4r, A5r, B4, B5, B5r *1 Sent As A4. *2 Sent As B4 Short.; Fax Memory: Up To 30,000 Pages (2,000 Jobs); Fax Features:Senders Name (Tti), Selecting The Telephone Line (When Sending Fax), Direct Send, Delayed Send, Preview, Finished Stamp, Job Done Notice, Tx Report, Interrupt Transmission, Sequential Broadcasting, Password/Sub-Address Sending, Confidential Mailbox Store Specifications- Memory Media: Standard: Usb Memory, Security Specifications; Authentication & Access Control: User Authentication(Picture Login, Picture And Pin Login, Username And Password Login, Function Level Login, Mobile Login), Department Id Authentication(Depertment Id And Pin Login, Function Level Login), Uniflow Online (Pin Login, Picture Login, Picture And Pin Login, Card Login, Card And Pin Login, Username And Password Login, Depertment Id And Pin Login, Function Level Login), Access Management System(Access Control);Network Security:Tls 1.3, Ipsec, Ieee802.1X Authentication, Snmpv3, Firewall, Functionality(Ip/Mac Address Filtering), Wpa3 Support (Wi-Fi), Dual Network Support(Wired Lan/Wireless Lan, Wired Lan/Wired Lan), Enabling/Disabling(Network Applications, Remote Ui, Usb Interface), G3 Fax Separation From Lan, Usb Port Separation From Lan, Scan And Send -Virus Concerns For E-Mail Reception Document Security -Print Security(Secure Print, Encrypted Secureprint, Forced Hold Printing, Uniflow Secure Print 1),Receive Data Security(Confidential Fax Inbox Forwarding Received Documents Automatically), Scan Security (Encrypted Pdf, Device Signature Pdf/Xps, User Signature Pdf/Xps112), Send Data Security(Setting For Requesting Password Input Per Transmission, Restricted E-Mail/File Send Functions, Confirming Fax Number, Allow/Restrict Fax Driver Transmissions, Allow/Restrict Sending From History, S/Mime Support) Environmental Specifications- Operating Environment: Temperature: 10 To 30 °C (50 To 86 °F);Humidity: 20 To 80 % Rh (Relative Humidity); Power Source: Eur: 220-240V 50/60Hz 10A; Power Consumption: Maximum: Approx. 1,500W,Copying (With Dadf Continuous Scan): Approx. 666W (220-240V)*1,Standby: Approx. 28.1W (220-240V)*1,Sleep Mode: Approx. 0.8W*2,* 0.8W Is Not Available In All Circumstances Due To Certain Settings.,*1 Reference Value: Measured One Unit,*2 0.8W Is Not Available In All Circumstances Due To Certain Settings.,Typical Electricity Consumption (Tec): 0.48 Kwh*,*As Per Energy Star Version 3.0 Software & Printer Management- Tracking & Reporting: Uniflow Online; Remote Management Tools: Iw Enterprise Management Console Emaintenance Content Delivery System; Scanning Software: Network Scangear;Toner Cartridge/S: Toner C-Exv 67 Black; Toner Estimated Yield:33,000 Pages (A4), (Estimated @ 6% Coverage); Cassette Feeding Unit:Cassette Feeding Unit-Aw1: Paper Capacity: 550 Sheets X 2 (1,100 Sheets) (80 Gsm), Paper Type: Thin, Plain, Recycled, Color, Heavy, Bond, Transparency, Pre-Punched, Letterhead Paper Size: A3, A4, A4r, A5, A5r, A6r, B4, B5, B5r,Custom Size: 105.0 X 148.0 Mm To 304.8 X 457.2 Mm,Paper Weight: 52 To 256 Gsm,Power Source: From The Main Unit Dimensions (W X D X H): 565 X 635 X 248 Mm,Weight: Approx. 16.0 Kg Output Options- Copy Tray: Check For Impacted Products.; Copy Tray:Inner 2Way Tray-M1:Tray Capacity (With 80 Gsm Paper):Upper Tray: Sra3, A3, A4, A4r, A5, A5r, A6r, B4, B5, B5r: 100 Sheets,Lower Tray (Standard Tray): A4, A5, A5r, A6r, B5, B5r: Up To 250 Sheets,Sra3, A3, A4r, B4: Up To 100 Sheets Paper Weight: 52 To 300 Gsm, Dimensions (W X D X H): 428 X 405 X 88 Mm,Weight: Approx. 0.7 Kg, Inner 2-Way Tray-Copy Tray-T2:Capacity (80Gsm Paper):A4, A5r, B5, B5r: 100 Sheets,A3, A4r, B4: 65 Sheets,Dimensions (W X D X H): 444 × 373 × 176 Mm (Attached To The Main Unit, When The Extension Tray Is Extended),Weight: 0.5 Kg, Inner Finisher - Inner Finisher-L1:Upper Tray: Sra3, A3, A4, A4r, A5, A5r, A6r, B4, B5, B5r: Approx. 45 Sheets,Lower Tray: A4, A5, A5r, B5: Approx. 500 Sheets Sra3, A3, A4r, B4, B5r: 250 Sheets,A6r: 30 Sheets,Envelope: 10 Sheets Paper Weight: 52 To 300 Gsm,Staple Position: Corner, Double,Staple Capacity: A4, B5: 50 Sheets (52 To 90 Gsm),A4r: 40 Sheets (52 To 90 Gsm),A3, B4: 30 Sheets (52 To 90 Gsm),Eco Staple: A3, A4, B4, B5: 10 Sheets (52 To 64 Gsm)/8 Sheets (65 To 81.4 Gsm)/6 Sheets (82 To 105 Gsm),Staple On Demand: Approx. 40 Sheets (80 Gsm) Dimensions (W X D X H): 727 × 525 × 225 Mm (Attached To The Main Unit, When The Extension Tray Is Extended),Weight: Approx. 9.1 Kg Hardware Accessories- Card Readers: Ic Card Reader Attachment-B4 Attachment Kit For Reader-A2; Print Accessories- Pcl International Font Set-A Ps Printer Kit-Bt1; Send Options: Universal Send Trace & Smooth Pdf Kit-A1 Universal Send Digital User Signature Kit-C1; Barcode Printing: Barcode Printing Kit-D1; , Audio Accessories-Ahuja Wired Mikes , Audio Accessories-Ahuja Cordless Mikes , Audio Accessories-Mike Stand (Tall And Small), , Audio Accessories-Cordless Mike Holder Cap, , Audio Accessories-Wired Mike Holder Cap , Audio Accessories-Jack To Jack Wired , Audio Accessories-3 Pin Xlr Male To Xlr Female , Audio Accessories-Universal Aaa And Aa Battery Recharger Adapter , Audio Accessories-Aa Recharge Batteries, Aaa Recharge Batteries , Audio Accessories-Mains Power Cable Cords
Contract Date: Ref. Documents Contract Value : Ref. Document
Private Organizations No of Bidders 3
46.
Defence #10801071 Price Bid
Tender For Comprehensive B R And Em Repair Maintenance Works To 14 Asc Af Kakkanad Under Age I R D Kochi; 1 Hacking out old broken glass panes 4 mm thick from steel frame including putty/ metal beadings and supply and fix sheet glass ordinary 4 mm thick, in squares n.exc. 0.50 Sqm in each pane including necessary new oil putty or with existing metal beadings complete all as specified and as directed 2 Hacking out old broken glass panes 4 mm thick from wooden framed shutters including putty/wooden beadings and supply and fix sheet glass ordinary quality, 4 mm thick, in square n.exc. 0.5 Sqm in each pane including necessary oil putty/wooden beads complete all as specified and as directed. 3 S&F in repairs extruded aluminium anodised 150 mm long handles fabricated type. 4 All as per item No 3 above but 100 mm long. 5 Supply and fix in repairs foot operated door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring and cover plate overall length 150 mm including taking down defective foot operated door stopper all as specified and as directed. 6 S&F in repairsmortice lock brass 4 levers vertical type 100 mm 7 S & Fin repairs door closer hydraulically regulated, castiron body, designation No -3, universal type ,suitable for door shuttersof 851 to1000 mm in width and of wt between 61 to 80 Kg and fixed 8 Re securing and easing to wooden shutters of any description area n.exc 1 Sqm each without taking down the shutter all as specified and as directed. 9 Re securing and easing to wooden shutters of any description exc 1 Sqmbut n.exc 2 Sqm each without taking down the shutters all as specified and as directed. 10 S&F In repairs Aluminium anodised, barrel tower bolts of extruded section 150 mm long. 11 All as per item No 10 above but 100 mm long. 12 S&F in repairs Aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy, 300 mm long 13 Taking down shutters exc 1 sq. m and n exc2 sq. m each and re-fixing in same openings. 14 Taking down shutters n exc 1 sq. m each and re-fixing in same openings. 15 S&F in repairs Butt hinges, medium weight cold rolled mild steel 100 mm size. 16 All as per item No 15 above but 75 mm size. 17 Taking down and removing to or from store chowkats or framesexc 1.5 sq. m and not exc 4 sqm each but with shutters (without taking off shutters from the frames) 18 S&F Solid PVC door frame of size 50mm x 47mm made of of 5mm plain color PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing. 19 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain color PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color PVC sheets for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain color PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. 20 S&F Aluminium, anodised, barrel tower boltsof extruded section and fixed length of bolt in 200 mm complete all as specified and directed. 21 S&F Butt hinges, medium weight, cold rolled mild steel, and fixed size of hinges in 100 mm complete all as specified and directed. 22 S&F Aluminium handles, cast type, anodised size of handle in 150mm 23 Supply and fix in repair PVC low level flushing cistern 10 liters capacity with ISI mark including inlet, ball valve, float, handle and brackets etc. including taking down old defective low level flushing cistern all as specified and as directed. 24 Supply and fix plastic seat and cover superior quality closed pattern with flat bottom of heavy duty including necessary hinged devices, including taking down damaged/ broken plastic seat and cover from EWC all as specified and as directed. 25 Supply and Fix in repair PVC connection with PTMT nuts of length 450 mm screwed for iron pipe15 mm bore. 26 Supply and fix in repair 15 mm dia CP pillar cocks fancy type for wash hand basin including taking down existing pillar cock, all as specified and as directed. 27 Supply and fix 150 mm square grating of PTMT to floor trap/nahani trap including taking down existing damaged CI grating from floor tap/nahani trap all as specified and as directed. 28 Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15mm bore pipe, all as specified and as directed. 29 All as per item No 28 above but 20mm bore. 30 All as per item No 28 above but 25/32 mm bore. 31 Supply and fix Unplasticised PVC pipes of bore 15mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 32 Supply and fix Unplasticised PVC pipes of bore 20mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 33 Supplying and laying of CPVC pipes 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 34 S&F in repairs bib taps 15mm bore, cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed for iron pipe or for brass ferrule all as specified and as directed 35 S&F in repairs stop valves 15mm bore, cast copper alloy chromium plated fancy type, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed. 36 S&F in repairs vitreous china wash basin white flat back, size 580x450mm excluding taps waste, chain and plug and porcelain stopper including brackets all as specified and as directed. 37 S&F in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe). 38 Supply and fix tubular towel rail aluminium anodised20 mm dia D type 60 cm long between flanges including taking down defective aluminium tubular towel rail all as specified and as directed. 39 Supply and fix in repair beveled edgedmirror of size 600 x 450 mm selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. 40 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore. 41 All as per item 40 above but 110 mm bore 42 S&F PVC (SWR) bends any radius 75 mm bore 43 Supply and fix in repairs 100 mm dia CIfloor trap/nahani trap including taking down existing damaged CI grating from floor trap/nahani trap 44 M&L Dismantling water tanks and removing to store exc 250 & n exc 500 capacity 45 M&L Dismantling water tanks and removing to store exc 500 & n exc 1000 capacity 46 M&L Rotational moulded polyethylene water storage tanks 500 litres capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia PTMT Ball valve high pressure all as directed. 47 Allas per item No 46 above but 1000 ltr capacity 48 M & L for PU injection grouting by making necessary holes of 8 to 10 mm in concrete to a depth of about 75mm using proper electric hammer drill. Fix new nipples of 8 to 10mm using aluminum pipes using neat cement or M-Seal for proper anchorage. Carry-out pressure grouting using shaligrout 2k /equivalent) using a proper grouting pump. Seal the holes properly after the grouting nipples have been removed all as specified and directed by Engg -In Charge. 49 Material and labour for taking down old plaster and rendering 10mm thick in CM 1:6 on other than fair faces of brickor concrete surfaces finishing smooth and even and smooth without using extra cement making good match the old surface finish. 50 M&L two coat of OBD over a coat of primer on newly plastered surfaces of wall including cornices and preparation of surfaces. 51 M&L pre laminated particle board 12mm thick interior grade pre laminated one side with decorative choice lamination and other side balancing white lamination fixture with screws to frame work 52 Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge 53 M&L Screed bed or bedding layer 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge 54 M&L Rendering 10 mm thick in CM 1:3 on brick or concrete surfaces, finished fair and even for receiving wall tiles. 55 S&F glazed ceramic coloured tiles 300 x 200 x 7 mm thickon vertical surfaces, set and jointed in neat cement slurry and pointed in white/colour cement to match over 10 mm thick rendering (backing coat)in cm 1:3, complete all as specified and directed by Engineer-in-Charge. 56 M & L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm In floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge 57 S&F Vitrified ceramic coloured tiles 10mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match 58 S&F in repairs health faucet 15mm size chromium plated standard size all as specified and directed. 59 Supply and fixed in repairs stainless steel wire cloth, 0.63mm nominal dia of wire and average width aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples 60 M&L for chip and remove all damaged and de bonded concrete and plaster from the RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars, removingthe debris with in a lead of 100 meters as directed by Engineer-in-charge. 61 M&L for supply and application of Nitobond EP (Manufactured by M/s Fosroc chemicals India Ltd) epoxy bonding agent over the old concrete surface complete all as specified and all as directed by Engineer-in-charge. 62 M&L for supply and application of rust remover/converter (Rebaklense RR of M/s Fosroc Chemicals India Ltd. or equivalent) or Amandur ,(manufactured by GK technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application complete all as directed by Engineer-in-charge. 63 M&L for plastering with Nitobond SBR (Styrene butadiene polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) modified cement mortar (1:4) under the slab to an average thickness of 40 mm (applied in two layers not exceeding 20mm each) , including the cost of all materials rent of tools and labour charges etc complete all as directed by Engr-in-charge. 64 M&L Preparation of newsurfaces of ceiling and applying two coats of distemper oil emulsion on ceiling over a coat of primer over 3 mm thick wall care putty plastered and other surfaces with alkali resistant priming paint complete all as specified. 65 Taking down cement plaster of any description on walls incl raking out joints, hacking for key scrubbing down with water 66 M&L for plastering in CM1:6, 10 mm thick on interior walls finished even and smooth w/o using extra cement. 67 M&L for plasteringin CM 1:3, 5mm thick on ceiling finished even and smooth w/o using extra cement 68 M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Professional pack of Asian paints) over a coat of external wall care putty n.exc 2 mm thick on new or old prepared plastered external surfaces . 69 M&L Preparation of Newsurfaces of internal walland applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 70 M&L Preparation of oldsurfaces of internal wall by complete removal of existing treatment , and applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 71 M&L Preparation of old surfaces of ceiling by complete removal of existing treatment, and applying two coats of distemper oil emulsion on ceiling over a coat of primer, plastered and other surfaces with alkali resistant paint complete all as specified. 72 Demolition of brick work / PCC block masonry work built in cement mortar etc complete all as specified. 73 M&L Precast Concrete block masonry with solid blocks in PCC 1:3:6 type C1 (using 20 mm stone agg) exc 10 cm in width and setting in mortar 1:4with minimum compressive strength of 5N/ sq mm complete all as specified and as directed. 74 M&L for providing and fixing Gypsum Board 12mm thick in walls fixed with screw as per manufacturer’s instructions complete all as specified. 75 Dismantling in Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified. 76 M & L Anodised aluminium snap grid frame work (size of grid 605x 605) mm for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified and as directed. 77 M&L for providing and fixing Exposed metal frame ceiling with fire resistant calcium silicate board of siliceous and calcareous material reinforced with cellulose fiber for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) fixed with screw as per manufacturer’s instructions complete all as specified. 78 Cleaning (mechanically)of sewage line/effluent drains 150/110 mm dia and disposing offthe sludge outside MoD land complete all as directed. 79 Removing the chokes in drains of WC/bath room/kitchen up to 1st manhole including cleaning of gully traps in single storey/ground floor of multi storeyed buildings, all as specified and directed. 80 Removing chokes in drains of WC/bath room/kitchen other than ground floor all as specified and directed. 81 Destruction of growth of weed plants with roots level on wall/ roof of building any height with weedicides such as Round up manufactured by Excel Chemical Industries and sprayed in and around roots and the place of possible growth of weeds as per manufacturer’sinstructions and making good the surfacescomplete all as specifiedand as directed. 82 Demolition of reinforced cement concrete in any position not otherwise specifically provided for 83 M& L for Precast RCC Cover slabs type B-1, 1:2:4 (20 mm graded stone aggregate as in slabs of drains including necessary form works. (Reinforcement bar will be measuredand paid separately). 84 M&L TMT bars 10mm dia and over cut to length bent to shape required, including, cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips 85 Demolition of cement concrete in any position not otherwise specifically provided for complete all as specified and directed. 86 M & L for 1:3:6 Type C-2 (using 40 mm graded stone aggregate) for surface channels anddrains all as specified 87 Extra for forming fair finished drain or channel 30 Cminner girth in cement concrete ,using extra cement, including forms, moulds, mitered /stopped endsetc 88 Opening manhole of septic tank remove night soil and sediments including liquid by mechanical pumping into tanker lorry having cleaning internal surface with water and re-fix the manhole covers, complete all as specified and directed. Notes :-(i)Volume of the manhole will be worked out based on the depth or actual depth of sludge, whichever is less.(ii) Water shall be procured by the contractor for cleaning purpose. 89 Demolition of cement concretein ground floors and pavings n.exc 15 cm thickness (below or above ground level) 90 M&L for 100mm thick PCC ( 1:3:6)type C-2,using 40mm graded stone aggregate as in hard standing/path/sub basefinished to an even and fair surfaces. 91 M&L forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade A. 92 Dismantling structural steel work incl doors, gates but excluding framed trusses. 93 S & FMS work in railings, balusters, posts and struts in fencing etc including cutting tops to shapeas directed, includingall necessary welding, drilling bolting or riveting etc and similar work conforming to FE 290 Gd E-165 complete all as specified 94 S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging with and including hooks and hinges, also fastening and fixing complete conforming to Fe-410W (Gde-E-250) 95 M&L for Point wiring for light point /fan point/Exhaust fan /Bell Pointwith 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. including dismantling /removing of burnt cable/making good surface asrequired . 96 M&L for submain wiring for 5 Amp socket outlet point on independent board with 2x 1.5 sqmm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multi standard copper conductors and earth continuity wire with similar 1x1.5 sqmm cable (incl connecting to earth dolly) drawn through and single core cable in surface/recessed medium class PVC conduit including dismantling /removing of burnt cable/making good surface as persiterequirement . 97 Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch and 5/6A modular socket ,connection etc. as required atsitecomplete all as specified and directed (for Independent 5 Amp socket ) . 98 M&L for wiring for circuit along with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required .wire 2x22.5 sq.mm + 1x2.5 sq.mm earth wire for 15/25 power plug/socket. 99 All as per item above but Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modularsocket ,connection etc. as required atsitecomplete all as specified and directed( for 15/16 Amp Socket ). 100 M&L for wiring for circuit along with 4 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface /recessed steel conduit as required .wire 2x4 sq.mm + 1x4 sq.mm earth wire (for Ac & Geyser ) 101 S&F Electronic ceiling fan regulator, modular type stepped /socket type heavy duty suitable to work on 230 volts complete all as specified and directed. 102 Supply & Fixing piano type 5/6 amps switch on the existing Switch box including connection as required on site. 103 Supply & Fixing piano type 2 way 5/6 amps switch on the existing Switch box including connection as required on site. 104 Supply & Fixing piano type 15/16 amps switch on the existing Switch box including connection as required on site. 105 Supply & Fixing piano type 3 pin 5/6 amps socket outlet switch on the existing Switch box including connection as required on site. 106 Supply & Fixing piano type 6 pin 15/16 amps socket outlet switch on the existing Switch box including connection as required on site. 107 Supply & Fixing 5/6 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 108 Supply & Fixing 15/25 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 109 Supply & Fixing 3 pin 5/6 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 110 Supply & Fixing 6 pin 15/25 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 111 Supply & Fixing modular bell push on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 112 Supply and fixing 1 or 2 module base & cover plate on existing modular metal boxes etc as required. 113 Supply and fixing 3 module base & cover plate on existing modular metal boxes etc as required. 114 Supply and fixing 4 module base & cover plate on existing modular metal boxes etc as required. 115 Supply and fixing 6 module base & cover plate on existing modular metal boxes etc as required. 116 Supply and fixing 8 module base & cover plate on existing modular metal boxes etc as required. 117 Supply and fixing LED light fitting 1X20W,220V high efficiency(efficiency up to 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-20-30/40/65-SL-DP-NWHor GM/ Panasonic/Havells etc. 118 Supply and fixing LED light fitting 1X10W,220V high efficiency(efficiency up to 100lm/w)polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-10-30/40/65-SL-DP-NWH or Havells /Panasonic/GM etc. 119 S & F in repairs LED 20W T8 Tube within built driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection, housing made of high grade polycarbonate cover, 2.5 KV internal surge protection, IP20 ingress protection, PCB mounted on extruded metal plate. Make: Crompton model No LT8-20-865-(2) or equivalent in Havells/C&S/ Phillips/Bajaj. 120 S&F switch socket combination 5 Amp with PVC box suitable for 230 Volt on surface. 121 S&F switch socket combination 15 Amp with PVC box suitable for 230 Volt in surface 122 M&L switch socket combination2 in 1, 6/16 Amp flush type in existing switch box. 123 All as per item above but 6 Amp flush type in existing switch box. 124 M&L forbell AC 230 V Single pole ding dong type. 125 Supply and fixing angular type batten holder insulator body of PVC/ polycarbonate type suitable for 10/9 W Led bulb. 126 Supply and fixing fan condenser / capacitor of size 2.25/2.5 suitable for ceiling fan of any sweep. 127 Supply and fixingonly LED lamp of 9 watt, Make : Crompton/ Havells /Panasonic 128 S&F of 20 Amps 240 V , SPN Industrial type socket outlet, with 2 pole and earth ,metal enclosed plug top along with 20 A C Curve ,SP MCB , in sheet steel enclosure ,on surface or in recess with chained metal cover for the socket outlet and complete with connections ,testing and commissioning etc. as required . 129 Supplying and fixing 6 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 130 Supplying and fixing 8 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB / RCCB/Isolator) 131 Supplying and fixing 4 way, Horizontal type , Three pole and neutral Dl sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) 132 Supply and fixing of 5A to 32 A rating, 240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole in the existing MCB DB Complete with connections, testing and commissioning etc ax required. 133 Supply and fixing of 5A to 32 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc ax required. 134 Supply and fixing of 63 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of Triplepole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc as required. Make: IndoAsain, HSN Code: 8536, Cat. Nos.: 810107 or equivalent make of LT/ Havells. 135 M & L LED Square surface mounted Led Panel 12w, PDC housing and high translucent frosted plastic diffuser makes it a robust Luminar and efficiency up to 100lm/w. Make: Crompton, Model no LCDSPLN-R-12-CDL or equivalent make of GM/Havells. 136 M & L LED Round and Square recess mounted 12w LED edge lit slim down light with die cast aluminium housing finished in premium white coating and efficacy up to 100lm/w suitable for false ceiling. Make Crompton, Model no LSCRM-12W-WW/NW/ CDL or equivalent make of GM/Havells. 137 Dismantling and taking down ceiling fan any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testingall as specified and directed. 138 M & L for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height ,dismantling ceiling fan motor , removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing newpainting to ceiling fanscompletewith synthetic enamel Grey paintby spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc , testing, re-fixing the same in original position complete all as specified and as directed by the Engineer - in - Charge.Note: Rate include the taking down the ceiling fan and deposited to MES store for checkingand repairing) 139 All as per Item above but for the Exhaust fan of 300 /450 mm sweep sizes: 140 S & F in repairs of LED 36W surface full lit luminaire with glare free uniform illumination with longer life and less maintenance available in 2x2 ft (> 100 lm/w).Make: Crompton, Model No LCTLSNE-36-FO-WW/TL/CDL or Havells /C&S/ Phillips/Bajaj. 141 Supply andLayingGI tubing medium grade of size 50 mm with and including all fittings such as bends, elbows, tees, short pieces etc complete in trenches of following sizes after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. Note- Excavation & earth work will be measured & paid separately. 142 All as per item above but 40 mm bore 143 All as per item above but 25 mm bore 144 Supply & Fixing of Size 50 mm GI tubing medium grade withand including all fittings such as bends, elbows, tees, short pieces etc complete on wall and ceiling or laid in floors after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. 145 All as per item No 4 above but 40 mm bore 146 All as per item No 4 above but 25 mm bore 147 All as per item No 4 above but 20 mm bore 148 Repairs to leakage /damaged G.I. pipe of size 50/40 mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples ,Bends etc. all asdirected by Engr- in- charge. Note:- G.I. pipe length will be measured and paid separately under relevant item of sch A 149 All as per item above but 25/20 mm bore 150 Supply and fix in repairs gun metal gate valve of size 50 mm ISI marked with iron wheel head screwed both ends all as directed. 151 All as per item above but 40 mm bore 152 All as per item above but 25 mm bore 153 All as per item above but 20 mm bore 154 All as per item above but 15 mm bore 155 S&F in repairs un plasticized PVC pipe, 25mm bore of pressure rating 10 Kg/ Sqcm with all fittings, fixed to walls, ceilings or in floors complete with snap clips hooks etc and taking out old unserviceable one all as specified an as directed 156 All as per item above butof size 20 mm bore dia 157 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil forlaying/taking out GI pipe line all as specified and directed. 158 Returning filling in including spreadingleveling watering and well rammingin layer not exceeding 25 cm in soft/loose soil all as specified and directed. 159 Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mabove the starting point all as specified and directed. 160 M & L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside of the RCC Under Ground Sump of10,000 Ltrscapacity by dewatering the sump and cleaning the complete inner surfaces by rubbing / scrapping by wire brush to removethe sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely including applying one coat of white wash to all the inner surfaces, and details of tanks like date of cleaning ,capacity of tanks etc shall be written on the outside of the tank with synthetic enamel paint with lettersize 20 cm high in white color , over a black backgroundof size 100x60 cmand charges included for pump set for de watering incl operator all as specified anddirected 161 M&L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside PVC Service tanks kept on roof top of buildings or on stagings, cleaning the surface using brush and other cleaning materials such as bleaching powder as required including writing the capacity of the tank and date of cleaning with white enamel paint over black back ground all as specified and directed for the following capacity of tanks at different locations on Technical/Residential Buildings all as specified and directed by Engr-in-Charge. 162 2000 Ltr capacity 163 1000 Ltr Capacity 164 500/300 Ltr capacity 165 S&F in repairs float Valve 40mm bore (Ball brass valves) high pressure type with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed and taking out old unserviceable one all as specified and directed 166 All as per item above but of size 25mm bore 167 All as per item above but of size 20mm bore 168 S&F in repair/replacement HDPE Tank cover suitable for 300 to 1000 Litr capacity and taking out old unserviceable one 169 All as per item above but for 2000Ltr capacity tanks 170 M&L for repair/replacement ofFoot valve of size 50mmbrass heavy duty including taking up the suction pipe and re-fixing the same after replacement of foot valve in to the sump for proper functioning of pump and taking out old unserviceable one all as specified and directed 171 Dismantling of Mono-block Pump set from the existing position for servicing including opening the pump replacing the unserviceable ball bearings of suitable size for capacities up to 5 HP including greasing complete all as specified and directed 172 Repairs and servicing of Electric chlorine dozing Pump/ system Make Sathya sai Aqua Pura Services with Ant siphon valve including servicing of pump and motor with repair/ replacement of unserviceable parts like piston, stroke controller, suction and delivery tubing, PVC foot valve, nozzle, solution tank inlet, PVC water tubing 15mmbore, gate valve 15mm size etc, complete all as specified and directed. 173 M&L for cleaning of pump sets starter panel after dismantling the incoming and outgoing connections from MCCBs /MCBs and replacing the old unserviceable gland, lugs, nuts &bolts, push buttons, indicating lamps, supporting insulators etc, and checking the serviceability of MCBs cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed 174 M&L for Replacement of unserviceable DOL Starter suitable for motor up to 5 HPincluding connections 175 M&L for Repairing the old Valve pit of dimension 60x45x45 cm by taking out plaster and rendering with 10mm thick CM(1:4) including PCC (1:3:6) TYPE C2 on base, brick work inCM (1:4) as required and applying two coats of white wash on plastered surface including applying two coats of synthetic enamel paint over one coat of red oxide primer over steel surfaces after preparation, complete all as specified and directed 176 M&L for painting pump set including preparation old surfaces and painting with two coats of synthetic enamel paint over a coat of red oxide primer including marking the signs, letters, Nos on the pump setof capacity up to 2HP all as specified and as directed. 177 M&L for painting of old painted GI pipe of any size on the external surfaces after preparation, located in and out of Pump House, by scrapping and cleaning of external surfaces and applying two coats of Sky Blue paint over a coat of red oxide primer complete all as specified and directed. 178 Dismantling , taking out complete burnt winding wire of submersible motor including cleaning of statorslots replacement of defective parts and rewinding with existing type & gauge ofcopper wireas per motor capacity and using new insulation material such as insulating paper sleeves etc. replacement of submersible cable as required length complete all as directed of rating 1.5/2HP Single phase 179 Repairs to leakage /damaged G.I. pipe of size 80 to 100mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples, Bends etc. all asdirected by Engr- in- charge. Note:- (i) G.I. pipe length will be measured and paid separately under relevant item of sch A 180 Material Labour for fixing Mechanical joint suitable 80 mm dia GI pipe, fabricated and made out of MS sheet of thickness 6/8 mm including welding work, rubber gasket, nuts, bolts and washers complete all as specified and directed by Engr in charge. 181 Comprehensive Maintenance, Servicing and carrying out periodical service to DG set along with AMF panel or standard panel like carry out oil service and routine checkup/maintenance as per manufacturers schedule, checking complete system of lubrication, cooling systems, air intake systems, fuel systems, exhaust systems, DC/AC electrical systems in DG Set as well as in AMF/Standard Panel, tightening bolts and nuts in engine and alternator related systems, etc and repairs including material for renewal/ replacement of minor defective parts of like connectors, MCBs , phase indication lamps etc for following capacity of DG sets all as specified and directed by Engr in charge. 182 35 KVA with AMF Panel installed at 14 ASC, AF Kakkanad 183 20 KVA with AMF Panel installed at 14 ASC 184 Note:The spares to DG Sets items as listed below as SUPPLY ONLY will be used whenever required only and it shall measured and paid separately under respective items. 185 The rate is inclusive of all items as required at site except those items as SUPPLY ONLY below to keep the DG Set along with AMF / Standard panel on monthly basis complete all as specified and as directed by Engr-in-Charge. 186 The contractor should attend any complaint / breakdown immediately on call basis and even no. of times without any extra cost. 187 Contractor should submit the inspection / maintenance report of every visit in spite of no of visits during breakdown calls including mentioning the status of DG Sets and spares any replaced 188 The old unserviceable spares replaced under comprehensive maintenance i.e. in sl No 02 of above BOQ is the property of contractor for which credit shall be deducted under respective items in schedule of credit. 189 All AMF panels and standard DG set panels should be well cleaned with CTC solution checking all the electrical connection and tighten for any loose connection. 190 Supply and replace of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 35 KVA complete all as specified and as directed. 191 Supply only Lub Oil Filter for DG set 15 KVA to 35 KVA 192 Supply only fuel filter forDG set 15 KVA to 35 KVA 193 Supply only Oil pressure gauge for DG set of any size/make 194 Recharging of Battery 12 Volts , up to180 AH any make / type by replacing electrolyte including replacement of unserviceable terminal posts , to the required standard complete all as specified andas directed . 195 Diesel hose of size 5/16 all as directed 196 Battery terminals one end socket and the other end clamp type including brazing work and applying jelly over the battery terminal and pole all as directed by the Engr in charge 197 Water hoses complete set of engineDG sets of cap 15 to 35 KVA 198 Repairs to 12 V self starter of DG set engine by dismantling, removing and replacing the old defective/worn-out bearings, servicing including replacement of carbon brush, bendix drive, cleaning commutator in armature etc assembling and testing for satisfactory function all as directed. 199 Supply only auxiliary contactor suitable for AMF panel of 15 to 35 KVA DG set 200 Supply only power contactor suitable for AMF Panel of 15 to 35 KVA DG set 201 Supply, install, testing & commissioning in repairs DC relay card/ PLA relay 12/24 volt DC for DG set any capacity including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed by Engr-in Charge, 202 Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 320 KVA complete all as specified and as directed. 203 Repairs to door of acoustic enclosure of DG set cap 20 KVA by taking down and replacing the door hinges and door lock including all M&L and as directed. 204 Supply only distilled water into battery capacity of 12/24 Volt 88/90/180 AH all as specified and as directed by Engineer-in-Charge. 205 Taking out old burnt out Automatic voltage regulator from DG setcapacity 15 KVA to 35 KVA alternator and replace with new AVR and includingtesting and checking voltage regulation ofthe DG set on full loadfor its satisfactory performance complete all as specified and directed by Engineer-in-Charge:- 206 M&L for dismantling of complete radiator assy for DG Set capacity 15KVA to 35 KVA from engine and taking out all, de scaling rusty, sludge and muddy particles inside the radiator by using of sodium hydroxide with water pressure cleaning complete, changing of radiator fan belt if required and re-fixing the radiator assy on its existing position and testing complete for its satisfactory performance with entire satisfaction of Engineer-in-Charge:- 207 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm buried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanized iron strip 25mm x 4mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire babric (APM) weight not less than 4 Kg/ Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and as directed by Engr-in-Charge. 208 Providing and fixing 25mm x 5mm G.I strip in 40 mm Dia G.I pipe from earth electrode including connection with G.I Nut, bolt, Spring, Waher excavation and refilling etc. as required. 209 Supply & Fix in replacement MCB SP 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 210 Supply & Fix in replacement MCB SPN 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 211 Supply & Fix in replacement MCB TPN, 40 -63 Amp, C-curve, 415 volt AC complete all as specified. 212 Supply & Fix in replacement AMF controller, three phases, 50 Hz, AC, auto/manual/test/off mode with necessary display complete all as specified. 213 Material & Labour for dismantling the alternator of DG Set of capacity 20 KVA to 75KVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connection of the alternator, shifting the alternator to workshop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the “F” class insulation and existing gauge and type of magnet wire which was on original motor, varnishing, heating, drying, greasing the bearing including replacement unserviceable bearing ,re-fixing the complete including connection to the terminal box of the alternator at workshop and shifting the same to the site, fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with engine connecting all electrical connection of the alternator and testing the DG set “OFF/ FULL LOAD” , matching to the existing range of RPM of the engine output voltage for 415 volt and testing complete all as per the direction of Engineer In Charge. 214 Material & Labour for taking down unserviceable heat insulation from exhaust piping and providing new heat insulation to exhaust pipe using 50 mm thick mineral wool inside the container & up to the exhaust stack. The insulation shall be cladded/ covered with 24G aluminium sheet. Pipe length shall be maximum up to12 Meter long from engineincluding necessary welding works, cladding works with wire mesh and aluminium foil, replace unserviceable supporting MC,angle iron 50 mm X 50 mm X 6 mm, suitable size flange, nut, bolt and washers as required includingweather cowl complete all as specified. 215 Material & Labour for dismantling carefully fuel injection pump (FIP) up to 6 cylinders engine of DG set and transporting to workshop, opening into parts, for maintenance, servicing, overhauling, tuning and calibration, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-assembling, re-fixing the FIP on its original position including to and from conveyance charge from site to workshop and back complete all as specified. 216 Material & Labour for dismantling exhaust manifold from the engine to detect the smoke leak, clean the manifold including welding works, replacement of unserviceable spares, packing, bellows, nut, bolt, washers, insulators, etc. reassembling and re-fixing on its base, testing by running the DG set No LOAD/FULL LOAD complete all as specified. 217 S&F in repair 1.5 Sqmm three core PVC insulated, unsheathed multi stranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge. 218 M&L for preparation of old paintedsurfaces of the DG set and fuel tankof following capacity by cleaning oily and greasy spots using CTC and material and labour for one coat of synthetic enamel paint using spray machine to the fuel tank and one coat of heat resistance paint to Engine / alternator complete all as specified and directed. 219 Note: - Colour code to be followed as under:-(i) Engine body - OG.(ii) Alternator - Siemens grey(iii) Fly wheel guard - Red(iv)Radiator -Black(iv)DG set canopy/complete body with two coats of superior qualitysynthetic enamel paint using spray gun (Area of painting not exceeding 3 sqm) including writingof incoming/outgoing feeder with letters, MES/SM Nos etc completeall as specified. For DG Set capacity 15 KVA to 35 KVA 220 M&L for disconnection of Diesel Oil tank with inlet and outlet diesel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil particle complete and re-fixing after at the same place and connecting complete with existing system including marking of tank showing the capacity in Ltrs and replacement of transparent PVC pipe complete all as directed by Engineer-in-Charge:-For DG Set capacity15KVA to 35KVA 221 Supply, install, testing & commissioning in repairs controller- Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connections good and renewed for up to DG set 35 KVA as per existing make complete all as specified and directed by Engr-in-charge. 222 M & L for Servicing of split type Air-conditioning unit comprising Indoor and Outdoor unit of any make/type having capacity 1.0/1.5/2 TR including attending breakdown including required tools and plants,minor electrical sparer like small piece of wire, insulation tape , screws required to rectify the complaints by replacing the spare partsin technical andresidentialbuildingat 14 ASC Kakkanad. Note: Spares required is measured and paid as respective items in Schedule A and all specified and directed by the Engineer - In - Charge. 223 Supply and charge refrigerant gas R-32/R-410 at site including testing all as specified and as directed by Engineer in charge . 224 Supply only Capacitor 36/40 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 225 Supply only Capacitor 50/60 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 226 Supply only Capacitor 80/100MFD suitable for 230 V 50 HZ AC supplyall as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 227 Taking out existing burnt fan motor single phase 230 Voltfrom the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the followingall as specified and as directed by Engineer - in - Charge. 228 Splittype AC capacity up to 1.5 Ton 229 Split type AC 2.0 Ton Capacity 230 Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR all as specified and directed by Engg-in-charge 231 Taking out carefully existing defective sealed unit compressorSupply & fixing factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge. 232 (a) Split type Ac 1.5/2.0 Ton capacity 233 Removing the damaged insulation of suction and discharge line & Supplying and fixing new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as directed by Engineer - in - Charge. 234 M&L in replacement of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make as specified and directed by Engineer in Charge. 235 Supply only new capacitor of Fan motor of 4 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 236 Supply only new capacitor of Fan motor of 10 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 237 Suply only split type AC indoor unit oscillation motorcomplete all as directed by Engineer - in - Charge. 238 Supply only thermostat for split type AC 1.0/1.5/2.0 complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA. 239 Supply & fix in replacement of factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc. , all as specified andas directed. 240 M & L Removing the split A/c unit from existing position, of capacity 1.5/2.0 Ton of any make and refix the same in other location by fixing the indoor and outdoor unit in position on fixing on wall/ floor as directed including piping refix the insulation, Gas charging filling the cavities on wall setting of grills alignment complete including, testing & commissioning to the entire satisfaction of Engineer - in - Charge. 241 Supply and fixreplacement 240V 20 Amp singlepole and earth enclosure with a two pin and earth plug and socket complete with one single poleMCB20 Amp SPAll as directedEIC .Make: Legrand , Cat No: 6078 41/Equivalent in L & T/Indo Asian. 242 Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 4.0 sq mmPVC unsheathed copper multi stranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/lvorycolour PVC conduit including multi stranded copper earth conductor 4.0 sq mm one run as earth continuity conductor all as directed by Engineer in Charge. 243 Supply and fixing in replacement of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No ENDURAPEARLNEOSL45LED757PASYTOPC or its equivalent make of Crompton/Bajaj/HPL/GM. 244 Supply, fixing, connecting and testing in replacement of 150 Watt LED flood light 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Havells Cat No JETAIRISFLS150WLED757PSYMLTG or its equivalent make of Crompton/GM/HPL. 245 Supply and fixing in replacement to ground with suitable pole mounting with OD of 76 mm, connecting and testing 40 Watt LED Post Top Luminaire, 230 Volt AC outdoor type with decorative post top for 360° indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Crompton Cat Part No LPTO-40-CDL/M or its equivalent make of Havells/Bajaj/GM/HPL. 246 Supply and fixing passing through pole cable 3 core PVC insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm from junction box to lightfitting all as directed by EIC. Make: Havells/Finolex/Poly cab. 247 Supply & fixing in replacement of transparent cover type street light junction box of size 168 mm x 253 mm x 115 mm made of high quality thermoplastic type with hinged and 4 Nos DIN mounted terminal suitable for 10 Sqmm XLPE cable, IP-66 (Dust and power jet Proof according to IEC 60529) , shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II ) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of poly-urethane with copper bus bar 25 x 5 mm -04 strip, one noMCB SP 6 Amps with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to, 10Sqmm cable etc and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clamps, nuts & bolt, etc. complete all as specified and directed. Make: Hensel Cat Part No KG 9002 or its equivalent make. 248 M & L for removal of existing treatment from PCC poles and applying two coats of weather proof exterior emulsion paint on old painted surface over a coat of primer, complete all as specified and directed by Engineer-in-Charge. 249 M&L for cleaning of feeder pillar/ panel after dismantling the Incoming and outgoing connections from MCBs and replacing the old unserviceable Gland, lugs, nuts & bolts, push buttons, indicating lamps, supporting insulators etc., and checking the serviceability of MCBs, cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed by Engineer-in-Charge.Note: Spares / materials charge for repair/replacement of worn-out parts shall be measured and paid separately under relevant items. 250 S & F in replacement of MCCB 4 Pole 100-125 Amps 415V 16 KA 251 S & F in replacement of MCB TPN63Amp, 4 Pole, C Curve 252 S & F in replacement of MCB DP 32-40Amp, C Curve 253 S & F in replacement of MCB SP 6 to 32Amp, C Curve 254 Comprehensive Maintenance, Servicing and carrying out periodical service to Voltage Stabilizer, servo type of capacity 63 KVA, 3 phase, 50 c/s, AC including along withrepairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at siteall as specified and directed by Engr in charge. Notes: 255 (a) Any additional parts required to be replaced will be measured and paid separately as Supply only against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. 256 (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department. (c) Following parts (if renewed) shall be measured and paid separately under appropriate items at Supply only rates and unserviceable parts retrieved through replacement shall be measured under Sch of credit. 257 Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 63 KVA, 3 phase, 50 c/s, AC supply of Make- Volteck or as per existing make and overhauling of the same by cleaning, servicing all serviceable accessories including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed.NOTE: - (i) Supply only spare parts shall be measured and paid separately under relevant items of this schedule. (ii)Transportation charge / labour charge during the repair of voltage stabilizer from the site to workshop are included in the items of this schedule 258 Supply only following spare parts of 63KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - 259 AC synchronous motor single phase, 50 Hz, 240 volts Make:UNI STEP or equivalent make suitable for volteck servo . 260 Variable auto transformer (Variac). 261 Sensing Transformer. 262 Carbon brush with holder complete. 263 Solid state sensing circuit. 264 RC Net work. 265 PCB connector. 266 Gear big. 267 Carbon fingers. 268 Variac Control CT. 269 Main Bushing with brass rod (insulator & rod). 270 High low cut off relay. 271 Series transformer. 272 Wiring Set. 273 Gear small. 274 Transformers oil filtering with test 275 Replacement of electronic control board 276 Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. 277 Supply, installation, testing and commissioning of street light timer control panel, on pole/wall/floor mounting made out of CRCA steel sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements as per manufactures recommendation and design complete all as specified and as directed.Make: Havells Cat Part No IHXTS09120 or its equivalent make of above specification. 278 S&F bracket for fixing to street light poles, made out of suitable dia for fitting of LED street light fittingsmedium grade GI pipe bend to shape inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paintall as directed by the Engineer-in- Charge. Make: TATA / Jindal / Surya Praksh. 279 Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.15 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front opening suitable locking arrangement having copper bus bar of 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following etc complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate. 280 Incoming:(a) MCCB 200 Amp 4 pole 36 KA Ics=100% of Icu with spreader & rom -01 No. (b) Indication Lamp Red/Yellow - 03 No (c) SP MCB 6A -03 Nos (d) MFM Meter with CT- 01 No (g) Provision for installation of KESB 3 Phase meter with necessary accessories. 281 Outgoings.(a) 125 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (b) 100 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (c) 63 A 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No.(d) 32 Amp 4 MCCB 16 KA, Ics=100% of Ics with spreader & rom -01 No. 282 M & L for re-filling of chemicals (minimum 25-30 ltrof Bentonite chemical / Graphite compound for each earth pit) in existing chemical earthing at technical area for achieving satisfactory earthing value with comprising of the Bentonitecomponents including necessary excavation/drilling for lift of cylindrical copper tubes from the ground and re-fixing the same by using Rig machine and providingenclosure with heavy duty plastic cover having locking arrangement including changing of electrode with pure copper chemical earthing electrode (length ofRod : 3 mtr Approx) for excellent conductivity & work efficiencycomplete all as specified and as directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
47.
Defence #10801064 Price Bid
Tender For Certain Provision Works In The Aor Of Age B/R-Ll Under Ge Kapurhtala.; 1 Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and directed by Engr-in-charge. 2 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil all as specified and directed by Engr-in-charge. 3 Excavating over areas in soft/loose soil exc 1.5m deep and not exc 3.0 m deep and getting out complete all as specified. 4 M&L Plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified. 5 M&L Plain cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified. 6 M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed by Engineer - in - Charge 7 M&L for plain cement concrete (1:5:10) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete and as in sub base of floors complete all as specified and directed by Engr-in-Charge. 8 Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out , returning filling in layers not exceeding 25cm including watering and ramming and removing surplus earth to a distance not exceeding 50 metre complete all as specified. 9 Use & waste fair finished flat surfaces Formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better 10 M&L for reinforced cement concrete Design mix M-25 (20mm graded aggregates) in Walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses 11 Form work to sides of concrete fdn footing base of columns and raft beams sides and soffits (if any) of fdn and plinth beams and similar wk vertical or to batter for rough finished surfaces. 12 Form work to sides of pillars, posts, struts, pier, columns square, rectangular or polygonal rough finished surface of concrete. 13 Form work to sides and soffits of floor or roof beams, beam haunching, lintel etc rough finished surfaces of concrete flats. 14 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;exceeding 200mm thick (Horizontal or sloping)all as specified and directed by Engr-in-charge. 15 RCC M-25 design mix as in fdn, including raft, fooling fdn beams, plinth beams bases for columns and mass concrete. 16 RCC M-25 design mix as inPlinth beams,Roof Beam, cantilivers, bressummers, lintel over 1.5m span all as specified and directed by Engr-in-charge.. 17 RCC M-25 design mix as in columns , pillars, piers, posts and struts etc. 18 M&L for RCC M-25 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, Chhajja and in shelves and the like complete all as specified and directed by Engr-in-charge. 19 M&L for TMT bars (Fe 500),10 mm dia and over in reinforcement cut to length, bent to shape required incl bending spirally cranking, hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified. 20 M&L for TMT bars (Fe 500), 5mm dia and over upto incl 10mm dia stirrups bending spirally or hooping for columns, hooking ends and binding with mild sleetwire not less than 0.90mm dia complete all as specified and directed. 21 M&L for framed mild steel work of grade E-165 (Fe-290) as in framed work such as doors, gates or Flat iron frame work for drain covers etc,complete all as specified. 22 Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors ; fixed with angle cleats or other connecting plates of Fe-290 grade E-250 complete all as specified. 23 S&F of GI steel expended metal of size 25*25mm cut to length, bent to shape required and tying with and including annealed mild steel wire galvanized, steel staples and fixed to wood or steel members, weight not exceeding 4 Kilogram per square metre complete all as specified. 24 S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250) quality B complete all as specified and directed by Engr-in-Charge. 25 S&F of Mild steel screw bolts 16mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and n exc 30cm long complete all as specified and directed by Engr-in-Charge. 26 M&L for Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and as directed by Engineer-in-Charge. 27 M & L for Pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and as directed by Engineer-in-Charge. 28 M&L for Old size Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 all as specified and directed by Engr-in-Charge. 29 M&L Brick work with sub class B burnt clay bricks (old size bricks) straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed by Engr-in-charge . 30 M&L for flush pointing to brick wallswith CM 1:3 complete all as specified and directed by Engr-in-charge . 31 Providing cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in copings, kneelers, apex stones, bed plates etc including necessary form work complete. 32 Extra for forming fair finish to drain or channel of cement concrete, 30cm inner girth, using extra cement including forms moulds/mitered stopped ends etc. complete all as spd. 33 M&l for Pre-cast Reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in manhole covers , Drain Covers and set in cement mortar (1:4) including form work complete all as specified. (Reinforcement measured separately). 34 M&L painting with synthetic enamel paint two coats over a coat of red oxide primer including preparing the new untreated steel surfaces of any description over 10cm in width or girth. 35 M&L for Boring 300mm Dia holes 10m deep in any type of soil for under-reamed piles and getting out and disposal of spoil to a distance of n exc. 50 mComplete all as specified and directed.. 36 S&F of UPVC pipes (SCH-40) (Slotted) 150mm bore dia incl all necessary fitting Complete all as specified and directed.. 37 S&F of UPVC pipes (SCH-40) (Blind)150mm bore dia incl Plug Cap and all necessary fitting Complete all as specified and directed.. 38 M&L for filling 12.5mm Graded coarse aggregates in harvesting pit upto height 0.50m Complete all as specified and directed.. 39 M&L for filling 3mm to 5mm PEA Gravel in harvesting pit Complete all as specified and directed.. 40 M&L for filling Coarse Sand in harvesting pit upto height 0.50m Complete all as specified and directed.. 41 M&L for Rendering 15mm thick on fair faces brick surfaces in cement mortar 1 : 4 finished even and smooth without using extra cement including WPC @ 3% of wt of cement complete all as specified. 42 Ditto all as per item sl no 14 here-in-before butin cement mortar 1:6 complete all as specified and directed by Engr-in-charge. 43 M&L for Rendering 10mm thick on fair facesof concrete surfaces surfaces in cement mortar 1 : 3 as in ceiling finished even and smooth without using extra cementcomplete all as specified. 44 M&L for preparation of new plastered surfaces of walls and applying 2mm thick of Birla white putty to obtain the true line to achieve smooth surface and applying two coats of oil bound distermper complete all as specified and directed by Engr-in-Charge 45 M&L applying two coats of exterior emulsion (Apex) paint on newly plastered or unplastered wall surface over a coat of cement primer including preparation ofsurfaces, complete all as specified and as directed. 46 M&L for preparation of new plastered surfaces of ceiling and applyingthree coats of white wash on ceiling and wall complete all as specified and directed by Engr-in-Charge 47 M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfaceunder floor and plingh protection all as specified and directed by Engr-in-Charge. 48 M&L for 100mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate)as in floor over hard core all as specified andm directed by Engr-in-charge. 49 M&L for 25mm thick plain Cement concrete type B-1, 1:2:4 (12.5mm graded aggregate) as on roof paddings and to receive tiles all as specified and directed by Engr-in-charge. 50 M&L 75mm thick PCC 1:3:6 type C2 as in plinth protection/hard standing finishing the surface even and smooth with out using extra cement 51 M&L for Anti-Termite Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area 52 M&L for Anti-termite Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface 53 M&L for Anti-termite Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area 54 M&L for 40mm thick in cement concrete Mortar 1:2:4 type B-0, Damp proof course to horizontal or vertical surfaces including necessary formwork all as specified and directed by Engr-in-charge. 55 M& L for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m all as specified and directed. 56 M&L for Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m all as specified and directed by Engr-in-charge. 57 Supply and fixing factory made uPVC white colour Two track two panels sliding glazed window upto 1.50m height made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 58 S&F 5.50mm thick Plain sheet glass, one side sheet glass is groundor obscured or frosted in squares exc 0.5 sqm each pane and glazing with metal beads all as specified. 59 M/L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular)area of each tile exceeding 0.11sqm but n.exc 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in CM (1:6) complete all as specified and directed by Engr-in-Charge 60 M&L for light shade Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed all as specified and directed by Engr-in-charge. 61 Ditto all as per item No 60 but in vertical surfacesover10mm plaster all as specified. 62 S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. 63 Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge 64 Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-inCharge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 65 S & F Aluminium (die cast body) Door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. 66 Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as spd. 67 Removal of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point all as spd. 68 Preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer @ 0.40 ltr/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymeric weighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under and over the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) and applying two coats of aluminium paint above APP membrane surface , complete all as specified and directed. 69 Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 70 M&L for Sand filing under floors or in foundations including watering and consolidation 71 M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658 - 2006 of 80mm thick ness, M-40 grade with grey cemet and pigment over sand cushioning complete all as specified. 72 Removing excavated material n exc.50M and depositingwhere directed at a level n exc1.5m above the starting point Note : (i) Excavated earth is used for area required earth filling.(ii) Charges of labour for earth filling is not given seperately it is considered in this item . 73 M&L Precast cement concrete block masonary with solid block (size 30x20x10 cm) as in edging ,type B1 1:2:4(20 mm graded aggregate) exc 10 cm in width and setting in mortar 1:4 complete 74 M&L Reinforced concrete 300 mm dia pipe class NP-3 laid & jointed complete with collars, complete all as specified and directed. 75 Material and labour for point wiring complete with two 1.5 Sqmm single core multistranded copper conductor PVC (FR) insulated cable in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.5 Sqmm insulated un-sheathed PVC insulated single core multistranded copper conductor common earth and connecting to earth dolly with suitable size of copper end connector for the following :- Note : (i) Colour code shall be maintained as per IE rule. 76 One light point controlled by one, one way switch 77 One fan point controlled by one, one way switch 78 One socket outlet 3 Pin, 5 Amp on independent board 79 One socket outlet 3 Pin, 5 Amp on same board. 80 M&L for point wiring with 4.00 Sq mm single core multi-stranded copper conductor PVC (FR) insulated, unsheathed cable 1100 volt grade in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 4.0 Sq mm single core, multi-stranded copper conductor, PVC insulated, unsheathed cable for common earth and connecting for earth dolly for 5 pin, 15 Amp socket outlet on Independent board. 81 S&Fswitch piano flush type single pole one way 5 Amp (ISI Marked) Make - Legrand/Schnider/Havells 82 S&F switch piano flush type single pole one way 15 Amp (ISI Marked) Make - Legrand/Schnider/Havells 83 S&F socket out let 2 in 1, 3 pin 5 Ampflush type (ISI Marked) Make - Legrand/Schnider/Havells 84 S&F socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) Make - Legrand/Schnider/Havells 85 M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) Make - Legrand/Schnider/Havells 86 Supply, installation, testing and commissioning of 20 watt 4 ft long LED Batten housing made of extruded alluminium with milky white diffuser and inbuilt electronic driver system lumen output should be at least 2000 lumen with a CCT of 6000 K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed. 87 Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete a CCT of 6000 K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed. Make Philips/Bajaj/C&S electric 88 Supply and install split AC indoor/outdoor 1.5 TR with in built Heating and Cooling operation and digital Inverter twin rotary compressor, AC,230V,single phase, with cordless remote control unitwith in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity and complete AC mounting stand along with clamps, nuts, bolts, washers etc. extra cooper tubing with proper insulation, PVC drain pipe of suitable length, Sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with MCB 20A, suitable for protection of appliances like AC/Geyser suitable for flush mounting and surface mounting complete all as specified. 89 Supply and fix LED Bldg security light fitting 35 W housing made out of die cast aluminum alloy with toughed glass, IP 65/66 protection having clamp for mounting on wall working on 240 V AC 50 Hz, 20 watts including fixed on wall with 02 Nos MS clamps and bracket made of 40 mm dia light grade GI pipe bend to shape. complete all as specified and as directed. Make : Crompton/Havells/Philips. 90 Supply, install, testing and commissioning of commercial Air Curtains of size 40 x 90 unit for prevention of dust and conditioned air losses, single phase, 240 V, 50 Htzs made out of MS/CRCA 18 gauge finished with two coat of red oxide primer and final coat of synthetic enamel paint(oven baked) with square perforated suction greels, aluminium alloys fans and single phase electric motor, nozle etc, complete with fittings and accessories so as to produce 1 -1.5 m/sec air velocity at floor level for door openeing specified.all as specified and directed 91 Supply and fix Voltage stabilizer for automatic operation, single phase Each naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V-with accuracy of ± 2.5% and of capacity 4 KVA. 92 S&F of DB epoxy powder coated TP & N 4 ways (VTPN MCCB DB) with metal door (IP 54 IK 09 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP MCCB 63 Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBS) outgoings complete all as directed. 93 S&F of MCCB, 63 Amp, Four Pole, 415 Volt Make - Legrand/Schneider-Acti 9/Siemens-Betagard 94 S&F of MCB,6 to 32 to Amp, SP , 230 Volt Make - Legrand/Schneider-Acti 9/Siemens-Betagard 95 Supply and fixing ceiling fans completewith blades, down rods and accessories, 230 V, 1200mm sweep. Min air delivery 210 CMMwith service value 6.00 BEE. Five starrated with brushless direct current motor(BLDC) and connecting up and including provision of twisted three core PVC insulated flexible cord of 0.75 Sqmm copper conductor of required length from ceiling rose/connector to fan complete all as specified and directed. 96 S&F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd 97 Supply, Installation and testing ofDesert Cooler electric driven (Single phase) for rooms up to 35 Sqm, large pad area for superior cooling, power ful fan , water tank capacity 51 ltrs including iron stand of suitable size as required to mount desert cooler on wall complete all as specified and directerd with following specifications :-Size of Desert Cooler - L x b x h 660 x 660 x 825 mm (26 x 26 x 32.5) ApproxFan Motor : (i) Fan motor should be copper winding, 500 mm Sweep Cooler fan, three speed (High/Medium/Low) with methalic blade duly painted with Snthetic anti corrosive oven cured paint fitted to body Fan motor Make : Bajaj/Khaitan/Crompton Greaves/GEC (ii) Input Cap 200 watt(approx), Speed 1400 RPM, 230 Volts, 50 Hz, Air Delivery 5000 Cum/HrsSubmersible Pump Motor: Input Cap 40 watt (Approx), Speed 1300 RPM, 230 volts, 50 Hz.Switches/Regulator: One Piano Switch and one Speed Selector Switch (Regulator) 04 Position for controll of Pump Motor and Fan motor respectively will be provided on the body.Pads : Wood wool Pads of proper Thickness will be provided in each panel (Set of three).Drain Plug : Brass drain plug shlall be provided from pump motor to three panel fitted on the cooler body.Cord : Flexible cord PVC Shethed and Insulated size 40/0.25 mm (1.5 Sqmm) 3 core (as per IS 694/1977) length 5 Mtr long with three pin 5 Amp ISI marked Bakelite plug Top shall be provided for power supply to cooler.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
48.
Rural Development #10787366 Price Bid
Regarding Supply Of Verious Type Of Material At Gram Panchayat Office Hingnakazi P.S. Malkapur Z.P. Buldhana , Miscellaneous Item , Supplying Integrated Led Street Light Fitting26 To 30W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing ,Having System Lumens Output Of Min. 2600 Lumens, Min. Efficacy Of 100 Lumen/W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50,Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf/Fls2. , Supplying 18W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying Integratedled Street Light Fitting 100-110W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing,Havingsystem Lumens Output Of Min. 11000 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50,Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf/Fls2. , Holder , 2.5Mm 2 Core Flat Cable 660/1100V. , Office Cupboard 19*36*78 , Office Cupboard19*36*54 , Office Table 2*4 , Office Table 2*3 , Computer Table 2.5*4.5 , Table Glass 2*4 , Table Cloth 2.5*4.5 , Office Revolving Chair , Office Revolving Chair Staff , Soft Cousion Chair , Branded Company Celling Fan 48 , Branded Company Wall Fan 400Mm , Branded Company Table Fan 400Mm , Branded Company Pedestal Fan 400Mm , Office Rack 19*36*78 , Fiber Chair , Stool , Dust-Bin 10 Lit (Swing Dustbin Material: Plastic, Color: Any Size: 28 Cm X 28 Cm X 39 Cm Made In India - Resistant To Uv, Heat Extra Strong 100% Virgin (Hdpe) Plastic) , Dust-Bin120 Lit (Material ?Plastic Special Feature ?Wheeled Shape ?Rectangular Product Dimensions ?56L X 49W X 94H Centimeters) , Dust-Bin Set 60 Lit Each With Metal Structure , Tricycle For Garbage Collection (- The Back Side Will Be Opened Manually.Back Side Will Be Raised Manually. All Saport Angle 25X25x2.5 Mm.Main Frame Angle 32X32x3mm.Sheet 20 Gauge.Patti For Saport 18X3mm.) , Electric Auto For Garbage Collection (Container Dimensions (L X W X H) 5 Ft X 3.25 Ft X 3.25 Ft Container Type 1 - Dry Waste, 1 - Wet Waste No. Of Batteries Required 4 (Lead Acid) / 1 (Lithium Ion) Charger 48V 15A) , Hand Wheel For Garbage Collection (Size/Dimension 450 X 700 X 300 Mm Thickness 2 Mm Surface Finish Color Coated) , Fogging Machine (4 Technical Specifications Engineoutput - 10.5 Kw Fule Tank Capacity – (Petrol) 1.2Litter Averagefuleconsumption(Approx)1.2 Litter / Hr Tank Capacity – 5 Litter Weight – 9.0 Kg Powerfulperformersuper Hand Pump Start ) , Satranji , Desk-Bench , Study Table , Metal See-Saw , Metal Sliding , Metal Zula , Branded Company Mixer Grinder , Branded Company Induction Food Macker (Pre-Set Timer For Hassle Free Cooking Warranty: 1 Year Warranty Power: 2000-2100 Watts; Operating Voltage: 220 - 240 Volts) , Branded Company Coocker 12 Lit (Material Aluminium Closure Type Outer Lid Colour Silver Finish Type Aluminium Product Dimensions 30.5D X 30.5W X 40.6H Centimeters) , Steel Bucket 15 Lit , Steel Handa 15 Lit , Steel Plate Medium Size ( Poha Plate ) , Metal Stroage Kothi 100Kg , Try Cycle For Kids , Water Purifier 18 Lit , Water Purifier 50 Lit , Water Jar/Can 18 Liter , Weight Machine , Led Smart Tv 32 Resolution: Hd Ready (1366X768), 2 Usb Ports To Connect Hard Drives And Other Usb Devices, Sound : 20 Watts Output | Dolby Audio, 1 Year Comprehensive Warranty , Led Smart Tv 40 Resolution: Hd Ready (1920 X 1080 Pixels), 2 Usb Ports To Connect Hard Drives And Other Usb Devices, Sound : 20 Watts Output | Dolby Audio, 1 Year Comprehensive Warranty , Led Smart Tv 50 Display: 4K Ultra Hd, 3840 X 2160 Pixelsconnectivity: 3 Hdmi | 2 Usb | Wi-Fi Operating System: Android Sound: 24 W Speaker, Dolby Audio Usp: Farfield Voice Control 1 Year Comprehensive Warranty , Sound System Set (100W Speakers 2 Nos, Wireless Mike 2 Nos, Amplifier 400W ) , Trolly Speaker Connectivity: Bluetooth | Aux | Usb | Memory Cardpower Output: 45Wconfiguration: Stereo Channelpower Source: Ac Adapterusp: In-Built Amplifier |True Wireless Speakers |8 Inches Subwooferwarranty: 12 Months Warranty , Cement Bench 58.4D X 177.8W X 78.7H Centimeters , Metal 3 Seater Bench 58.4D X 177.8W X 78.7H Centimeters , Hospital Bed (Bed Dimension (Lxwxh) Is 198 X 90 X 60 Cm, 1 Pcs Semi Fowler Bed , 1 Pcs Handles,) , Bed Side Locker (The Locker Is Made Of High-Quality Crca (Cold-Rolled Close Annealed) Steel, Which Is Known For Its Durability And Strength. The Dimensions Of The Locker Are 425 Mm X 425 Mm X 825 Mm, Making It Compact And Easy To Move Around.) , Examinaton Bed For Hospital ( Material:Â Mild Steel, Size:Â 1800 Mm X 600 Mm X 800 Mm,Drawer Size:Â 300 Mm X 300 Mm X 150 Mm,Footstep Size:Â 400 Mm X 400 Mm) , Jal Drop , Handwash Station , Supplying 230/250V, 50Hz, Evaporative Air Cooler (Desert Cooler) Duct Type Having Normal Cooling Capacity Of 100Cu.M Per Minute, With 15 Exhaust, Min 75 To 80 Litres Water Capacity Tankwith Galvanised Steel Sheet With Grade 350 Minimum, Leak Or Drip Free, Front Grill Shall Be Made Of Non-Corrosive Material, Circular Opening Shall Be More Than Fan Sweep Butnot Exceeding More Than 25Mm, Filter Pads Shall Be Made Of Wood Wool Or Any Other Substitute Placed In Non-Corrosive Wire Mesh And Tightened At Places With Side Panels, Noise Level Should Not Be More Than 65Dba At 1M Distance, 3 Core Copper Cable Minimum 2M Length & Metal Casing Of The Electrical Components, Metal Frame Or Chassis Of Cooler Cabinet And All Exposed Metallic Parts, Shall Be Provided With Proper Earthling Complete As Per Specification No. Ap-Wcr/Dac , Ladder 240 Inch , Bleaching Powder , Cement Tank For Water Storeage , Indian Hon. Leader Photo Frame 8*12 , Solar Light System With 4 Meter Pole, 15W Light, Having 12 Hour. Battery Backup Auto Deaming, , All In One Computer (Processor: 10Th Gen Intel Core I5-10210U | Speed: 1.6 Ghz Memory And Storage: 8Gb Ddr4 Ram Storage: 512Gb Ssd Display: 23.8Inch Full Hd (1920X1080) , All In One Printer (Printer Type: Functions: Print, Scan, Copy ; Printer Output: Monochrome ; Connectivity: Usb ; Scanner: Yes ; Scanner Resolution: 600 X 600Dpi Mobile Connectivity : No ; Hardware Interface: Usb 2.0 Hi-Speed ; Enlarge/Reduce Option: No ; Duplex: No Warranty - 1 Year Warranty ) , 1000Lph Capacity Semi Automatic Ro Plant 1)Raw Water Pump 1.0 Hp 2)Sand Filter 13 Dia* 54Mm 3)Carbon Filter 13 Dia* 54Mm 4)Micron Filter 5 Mic 20 (2Qty) 5)High Pressure Pump 1000 Lph 2 Hp 6)Control Panel 7)Anti Scalatant Dosing Pump 0 To 6 Lph 8)Rota Meter 0 To 2400Lph (2Qty) 9) Pressure Guagee 0 To 7 Kg/Cm2 (2Qty) 10)Membrane 4040 (4 No.) Or 8040 (1 No.) 10)Ss Pressure Vessel 4080 (02Qty) Or 8040 (1Qty) 12)High Pressure Switch 13)Low Pressure Switch 14)Floaty 15)Uv System , Installation, Transportation, Loading, Unloading, Pipes, Accessories Fitting Etc. For 1000 Lph Ro System. , Pvc 3 Layer Food Grade Tank 1000 L , Water Atm Machine Card + Coin , Atm Card , 5 Kva Stabiliser For Ro And Chiller , Providing And Installation Of Chiller Plant Of 2 Tr Capacity , Fogging Machine Medicin , Frc Urinal Cabin 3*3*7 (Lxwxh) Feet , School Bag , School Uniform 22No. , School Uniform 24No. , School Uniform 26No. , School Uniform 28No. , School Uniform 30No. , Pvc Pipe 75Mm 4Kg , Pvc Pipe 75Mm 6Kg , Pvc Pipe 90Mm 4Kg , Pvc Pipe 90Mm 6Kg , Pvc Pipe 110Mm 4Kg , Pvc Pipe 110Mm 6Kg , Pvc Pipe 160Mm 4Kg , Pvc Pipe 160Mm 6Kg , Supplying, 1 Kwp Off-Gridsolar Power Pack Withinterconnectingwires / Cables Up To 12 V Pure Sine Wave Solar Power Inverter (Thd<3%), Spv Modules (335 Wp X 03 Nos.), C-10 Rated Lead Acid Battery Bank 12 V, 400 Ah (12V, 100 Ah X 4 Nos.)Suitable For 4 Hours Backup With Suitable Ms Powder Coated Stand To Holdbattery Bank And Keeping Sufficient Space For Filling Distilled Water, Canopy Box To House Inverter And Other Electronics, Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board , Two Distinct Earthing, Spike Type Lightning Arrester, Necessary Accessories Complete With 5 Years On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ofg , Supplying,3 Kwp Off-Gridsolar Power Pack With Interconnecting Wires / Cables Up To 24 V Pure Sine Wave Solar Power Inverter (Thd<3%), Spv Modules (335 Wp X 09 Nos.), C-10 Rated Lead Acid Battery Bank 24 V, 600 Ah (12V, 300 Ah X 4 Nos.)Suitable For 4 Hours Backup With Suitable Ms Powder Coated Stand To Hold Battery Bank And Keeping Sufficient Space For Filling Distilled Water, Canopy Box To House Inverter And Other Electronics, Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Spike Type Lightning Arrester, Necessary Accessories Complete With 5 Years On-Site Warranty Andfully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ofg , Supplying 5 Kwp Off-Gridsolar Power Pack Withinterconnectingwires / Cables Up To 24V Pure Sine Wave Solar Power Inverter (Thd<3%), Spv Modules (335 Wp X 15 Nos.), C-10 Rated Lead Acid Battery Bank 24V, 300Ah X 4 Nos. (12V, 300 Ah X 8 Nos)Suitable For 4 Hours Backup With Suitable Ms Powder Coated Stand To Holdbattery Bank And Keeping Sufficient Space For Filling Distilled Water, Canopy Box To House Inverter And Other Electronics, Wiring Up To Solar Inverter In Casing And Capping,Display Board, Sign Board, Two Distinct Earthing, Spike Type Lightning Arrester, Necessary Accessories Complete With 5 Years On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ofg , Supplying, Installing, Testing And Commissioning Of 3 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 09 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping,Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card / Chip For 5 Years Including Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong , Supplying, Installing, Testing And Commissioning Of5 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 15 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card/Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong , Supplying, Installing, Testing And Commissioning Of10 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 30 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card/Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong , Supplying, Installing, Testing And Commissioning Of 15 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 45 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card/Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong , Supplying, Installing, Testing And Commissioning Of20 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 60 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping,Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card/Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong. , Supplying, Installing, Testing And Commissioning Of25 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 75 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card / Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty And Fully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong. , Supplying, Installing, Testing And Commissioning Of100 Kwp On-Grid Solar Pv System / Plant Consisting Solar Pv Poly Crystalline Panel (335 Wp X 300 Nos.) And Solar On-Grid Inverter Of Similar Capacity (Thd<3%) With Interconnectingwires / Cables Up To Solar On Gridinverter, Proper Base Plate, Canopy Box To House Inverter And Necessary Accessories I.E. Acdb/ Dcdb , Mcb Etc. Wiring Up To Solar Inverter In Casing And Capping, Display Board, Sign Board, Two Distinct Earthing, Lightning Arrester, Liaisoning Charges, Remote Monitoring System With Maintaining Card / Chip For 5 Yearsincluding Net Charges For Rms System, Complete Up To Net Meter Installation And Export To The Grid With 5 Year On-Site Warranty Andfully Comprehensive Maintenance Contract As Per Specification No. Esd-Rt-Ong. , Supplying And Erecting 12V/200Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete , Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 2500 Va Digital Pure Sine Waveinverter With Backup Time Of ........ Hrs. Based On Insulated Gate Bipolar Transistor (Igbt) Technologycompleteas Per Specification No.Ap-Inv , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 2 Core 10Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipeas Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core16sq. Mm.Aluminium Conductor Completeerected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipeas Per Specification No. Cb-Lt/Al , Supplyinganderectingsingle Phase 10 To 60 A Net Meter Of Accuracy Class 1.0, 240V, 50 Hz,With Backlitlcd Display, Optical Port ( Measures Import Kwh, Export Kwh, Net Kwh, V, I, Kw, 12 Months History Of Energy)With Wiring Connections And Mountinghardwareonprovidedpanelscompletewith Calibration Certificate From Manufacturer. , Supplyinganderectingiron Work, Sheet Metal Work Consisting Of Crcasheets, Varioussectionsofiron,Plates, Chequeredplates,Rods,Bars,Mspipes,Etc. Forpanel Board Or Any Other Purpose With Bending, Cutting, Drilling And Welding Completeerectedatthepositionwith Necessarymaterialsdulypaintedwith One Coat Of Red Oxide And Two Coats Of Enamelpaint To Match The Switchgears Or As Per Directions By The Authority. , Supplying, Installing, Testing & Commissioning Split Type Variable Speed Invertertechnology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.3Tr To 1.6Trcapacity Having Iseer Minimum 5.00 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac/ Wac , Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump (Monoblock), 230V, Single Phase 50 Cycles A.C. Supply Of0.375 Kw/0.5 Hp With Discharge 285/67 Litres Per Minute (Lpm) For Head Of 6/13.8 M& 40 Mm Suction/ 40 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp , Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Of 2.25 Kw/3 Hp With 415 V, 50 C/S Ac Supply Suitable For 150 Mm Dia. Borewell Suitable For 120 To 475 Lpm Discharge At 36 To 10 M Head & Discharge & Delivery Pipe Of Size-50 Mm Diameter With A Necessary H Type Clamps As Per Specification No. Wp-Smp , Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Suitable For Erection On Open Well Of 5.625 Kw/7.5 Hp With 415 V 50 C/S. A.C. Supply, Having Delivery Head From 57 To 22 M And Discharge From 120 To 900 Litres. . Per Minute & Pipe Of Suction 75 Mm/Delivery 65 Mm Diameter Erected With Necessary H Type Clamps As Per Specification No. Wp-Osp , Supplying & Erecting Flat Flexible 3 Core 10Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. , 5000 Lit Water Tanker , Resistance Bands , Treadmills , Free Weights , Battle Ropes , Rowing Machines , Ellipticals , Weight Benches , Power Racks , Cable Machines , Cardio Equipment , Suspension Trainers , Weighted Sleds , Stability Balls , Dumbbells , Lat Pulldown Machine , Chest Press , Pearl Delt/Pec Fly , Butterfly , Shoulder Press , Lateral Raise , Fixed Pulldown , Lat Pulldown , Rowing Machine , Biceps Curl , Triceps Extension , Dip / Chin Assist , Leg Press , Leg Extension , Adjestable Extra Weight Plate 5Kg Set , Shev Peti 3*3*7.5
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
49.
Power #10781494 Price Bid
Tender For Overhauling Of 33Kv Vcbs And Painting Of Rusted Equipments At 132Kv Substation Manduadih, Under Electricity Transmission Division-I, Varanasi - Complete overhauling of 33KV Vacuum Circuit Breakers installed at 132KV S/S Manduadih. Job Includes alignment of mechanism assembly by opening and adjusting its operating rod, holding latch and damping spring etc. Replacement of damaged washers, lock pins, small springs etc. as per requirement during the work. Assembling the mechanism followed by oiling, greasing and tightening of all nuts & bolts of the mechanism box, checking & tightening of all AC/DC connections/terminals, proper checking the spring charging motor along with replacement of its carbon, removing the deposited dust/carbon on terminals by good quality CRC spray, checking the proper tripping & closing of VCB from local and remote including measurment of opening, closing time & contact resistance of CB pole by latest colibrated testing kit and other associated works also if required for satisfactory completion of job. Cost includes of All labour, T&P and consumable items will be provided by contractor at his own cost. 2 Spray painting of following rusted equipments with one coat of good quality red oxide primer and two coats of light gray color synthetic enamel paint of first class quality Asean/Nerolac/ Berger/Shalimar make after proper cleaning/rubbing of rust/dust and oily surface by emery/sand paper and hardwire brush including the cost of all material, labor and T&P. 3 132KV CT/PT (Top cover shall be painted with Red, Yellow and Blue colour as per phase sequence) 4 Junction Box of 132KV CT/PT 5 132KV Isolator base 6 132KV Isolator Junction Box 7 132KV Circuit Breaker 8 33KV Circuit Breaker 9 33KV CT/PT 10 Junction Box of 33KV CT/PT/CB 11 Spray painting of following 132/33KV, 40MVA Power Transformers. Work includes cleaning of transformer by castic soda and kerosin oil, scrubbing the top and outer surface, rubbing and complete cleaning the top and outer surface. Applying of one coat of red oxide primer and two coats of synthetic enamel light gray paint of first class quality Asian/Nerolac/Berger/Shalimar make and also painting its associated earthing, riser etc. with green color, bushig top in red, yellow and blue color as per phase sequence. Work including the cost of all material, labor and T&P. 12 132/33KV, 40MVA T/F-I (Bharat Bijali Make) 13 132/33KV, 40MVA T/F-II (Alstom Make) 14 132/33KV, 20MVA T/F-II (Schnieder Make)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
50.
Power #10779970 Price Bid
Tender For Overhauling Of 33Kv Circuit Breaker At 220Kv S/S Sultanpur Under Electy. 400Kv S/S Division, Sultanpur. - Overhauling and Servicing of 36 kV Vacuum Circuit Breakers at 220KV S/S, Sultanpur (for various 33 KV feeders):The scope of work includes:• General cleaning and lubrication of the operating mechanism after dismantling.• Checking and tightening of all locking pins, nuts & bolts.• Setting and adjustment of the tripping and closing mechanism.• Checking and adjustment of the connecting pole and main rods, and verifying their operation.• Overhauling of the spring charging motor, including gearbox maintenance.• Replacement of carbon brushes and polishing of the commutator as required.• Checking and replacement of the MCB as needed.• Setting of limit switches after thorough cleaning using CRC/CTC.• Checking tightness and integrity of all electrical connections.• Final checking of auto spring charging functionality.• Checking pole operation, including measurement of individual contact travel distances.• Checking and repairing housing seals as necessary.• Measurement of insulation resistance (megger value) in open condition, including vacuum checking.• Verifying tightness of all electrical connections in auxiliary contact blocks and control terminal blocks.• Checking and adjustment of trip and close levers and coils.• Checking of all alarms and indicators.• Verification of electrical and mechanical operation of the circuit breaker, including local and remote operation.All works shall be carried out with complete provision of manpower, materials, miscellaneous consumables, tools, and plants (T&P) required for the job.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Uttar Pradesh View Result →
TenderDetail
Loading tenders