View Bid Results For Provision Of Granite Tile Tenders

We found 1204 Bid Results related to provision of granite tile tenders. You can find Contractor details who won provision of granite tile tenders along with contract details in Bid awards announcements section.

Filters
Stage
936
165
103
Tender Publishing Platform
20
1184
State / UT
36
194
132
111
97
62
61
59
57
55
48
43
38
30
28
26
24
22
15
13
13
11
10
10
8
7
6
6
4
3
3
2
2
1
1
1
1
Contract Value
271
65
691
176
Publish Date
3
0
0
0
0
Sector
29
627
221
115
38
27
25
23
18
18
16
13
8
8
7
6
4
4
4
3
3
3
3
3
2
1
1
1
1
1
Ownership
6
634
318
180
60
7
5
Within keyword
Active filters:
Showing 1–25 of 1204 tenders matching your filters
1.
Defence #11478095 Technical Bid
Tender For Provision Of Certain Revenue And Minor Work At Age B/R Ii Under Ge(N) Patiala=- 1 Dismantling, Floor, Hearth Or Wall Tiling Including Cm (Bedding (But Not Backing), Removing Serviceable Tiles To Store & Rubbish Off The Premises Complete All As Specified And Directed 2 M&L For Single Charge, Vitrified, Stain & Scratch Resistant, Premium Quality Coloured Tiles Area Of Each Tiles Exceeding 0.42 Sqm But Not Exceeding 1.00 Sqm, In Floors Etc Mm And 8-10 Mm Thick, In Any Pattern Of Light & Dark Tiles As Approved, Laid Over 15 Mm Thick Screed In Cm (1:6) Epoxy Cartridge Tile Grout Using Filling The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour,Complete All As Specified And Directed. 3 All As Per Item No 2 Above But As In Skirting Over 10 Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. 4 M&L For Ceramic Glossy Finish, Joint Free Premium Quality Coloured Tiles 600 X 300 Mm And 8-9 Mm Thick, In Any Pattern Of Light & Dark/Highlighters Tiles Etc As Approved, On Vertical Surfaces Such As In Skirting/Dado Etc, Set And Including 10 Mm Thick Rendering In Cement Mortar (1:4) And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 5 M & L For 15 Mm Thick Artificial Granite (Of Any Type) Work Steps, Jambs, Pillars, Window- Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite. Including Screed Bed Or Bedding Layer Of Mortar 20 Mm Thick For Laying Floor Finishes Complete All As Specified. 6 Providing And Laying Premium (1St) Quality Straight Edge, Ceramic Tiles Exterior Grade Scratch Resistance Of Size 300X300X7 To 8 Mm Thick In Floors Etc. In Any Shade And Design/Pattern Of Light & Dark Tiles Etc Set And Including 15 Mm Thick Rendering In Cement Mortar (1:6) And Pointed In White Cement With Pigment To Match Complete All As Specified. 7 Taking Up Or Down Existing Steel Tubing And Connections, 15Mm Bore Complete All As Specified. 8 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 15Mm Bore Incl Fittings Complete All As Specified And Directed. 9 Taking Up Or Down Existing Steel Tubing And Connections, 20Mm Bore Complete All As Specified. 10 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 20Mm Bore Incl Fittings Complete All As Specified And Directed. 11 S&F In Repair Angle Stop Cock With Wall Flange 15Mm Cast Copper Alloy, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No-Fon-40053Pm Or Equivalent In /Hindware/Kohlar. 12 S&F In Repair 15 Mm Bore Bib Cock With Wall Flange, Cast Copper Alloy, Chromium Plated, Fancy Type With Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No Opp-15037Pm Or Equivalent In/Hindware/Kohlar. 13 S&Fin Repair Brass Chromium Plated Basin Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar Cat Part No Orp-10011Bpm Or Equivalent In /Hindware/Kohlar 14 S&F In Repair 15Mm Cp Connection 600Mm Long Including Washer And Brass Nuts All As Specified. 15 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 16 S&F In Repair Counter Top Wash Basin Of Size 600 X465Mm With Wash Basin Cabinet Size 600X455X600Mm Including Bottle Trap , Brass Waste Fitting Complete All As Specified. Make:-Cera/Hindware/Jaguar 17 S&F In Repair Toilet Roll Holder Stainless Steel Flap All As Specified. Make- Jaquar Cat Part No Can-1153S Or Equivalent In /Hindware/Kohlar 18 S&F In Repair Towelrack 600Mm Long With Lower Hanger (Stainless Steel) All As Specified.(Make: Jaquar Cat Part No Acn -1181S Or Equivalent In /Hindware/Kohlar 19 S&F In Repair Soap Dispenser With Glass Bottle (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1135N As Equivalent /Hindware/Kohlar 20 S&F In Repair Soap Dish Holder With Glass (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Akp -35731P Or Equivalent In /Hindware/Kohlar 21 S&Fin Repair Towel Ring Square With Round Flange (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1121N Or Equivalent In /Hindware/Kohlar 22 S&F In Repair Healthfaucet With 1Mtr Long Easy Flex Tube In Chrome Finish And Wall Hook Of 15 Mm Bore With Cp Pipe Complete Set Of Make -Jaquar Cat Part No Ald - 565 Or Equivalent In Parryware/Prayag 23 S&F In Repair Looking Mirror 5Mm Thick Size 3.5X3.5 Feet Incl Stud And Fastners Complete All As Specified And Directed. 24 S&F In Double Arm Wall Mounted Reversible Plain/Magnifying (X3) Pivotal Mirror All As Specified. Jaquar Cat Part No Acn -1193N Or Equivalent In /Hindware/Kohlar 25 S&F In Repair Glass Shelf Corner With Bracket Of Size 225Mm X 225Mm Thickness Of Glass 6Mm) With Cp Brass Railing And Brass Screws.Make- Jaquar Cat Part No Acn -1173 Or Equivalent In /Hindware/Kohlar 26 S&F Grating Doom 125Mm Of Ptmt. 27 S & F In Repair Vitreous China Urinal Half Stall Type White (Excluding Flushing Cistern ) Including Waste Fitting, Waste Pipe Complete All As Specified.Make-Jaquar/Hindware/Kohlar 28 S&F Ms Work In Tubular/Pipe/Angle Sections For Frame Work For Roof, Vertical Poles, Rafters And Purlins Including Washer Etc Complete All As Directed. 29 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. ( Design Of Sheet As Mangalore Tiles Pattern In Red Colour ). 30 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. 31 M & L Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Incl Preparation Of New Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. 32 M&L 25Mm Thick Factory Made Coloured Interlocking Designer Polished Floor Tiles (Ultra Pattern) Of Grade M-35 Of Shape And Size As Directed,And 100Mm X 100Mm Size Tiles Piece On Every Joint Of Tiles Flooring Laid Over & Including 20Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And Directed . Note: Sample Shall Be Got Approved From Ge Before Commencement Of Work 33 S&F In Repair Stainless Steel Drapery Rod Of 20 Mm Inner Dia (In Lengths As Directed) Of & Including Decorative Finial At Both Ends And Pair Of S S Steel Brackets Fixed At Both Ends With Pvc Rawl Plug & Steel Screws On Walls/Beam, (Victorian Design)All As Specified & As Directed. Make -Sample Can Be Seen In The Office Of Engg-In-Charge For Checking And Quoting The Same 34 Demolition Of Cement Concrete Un -Reinforced In Ground Floors And Pavings N.Exc 15Cm Thickness Complete All As Specified. 35 M& L For 25Mm Thick Pcc 1:2:4 Type Bo Using 12.5 Mm Graded Stone Aggregate As In Floor Complete As Specified And Directed. 36 S & F 75 Mm Dia Pvc ( Swr ) Floor Trap, Plain With Grating Including Jointing With Solvent Cement Complete All As Specified. 37 S & F Floor Door Stopper Of Aluminium Alloy And Tongue, Anodised With Hard Drawn Steel Overall Length Of Cover Plate 140Mm.As In Repairs Complete All As Specified. 38 Dismantling Of Wall And Ceiling Board(Fiblre, Pulp, Insulation Etc) Any Thickness Including Cover Fillets Complete All As Specified And As Directed. 39 S & F Powder Coated Aluminum Alloy Interlocking Snap Grid Frame Work For False Ceiling Size 600Mm X 600Mm Consists Of Main Tee Runners Of Size 38Mm X 38Mm X 1.5Mm And Cross Tee Of Size 38Mm X 38Mm X 1.5Mm, Spaced Between The Main Tee At 600Mm Centre To Centre To Form A Grid Of 600Mm X 600Mm Complete All As Specified And As Directed And As Per Manufacturer. Instruction. 40 M & L For 4Mm Thick Non Asbestos Fibre Cement Building Boards Of Make E Board Classic Designer Board (Cascade Or Occenic) Of M/S Everest Industries Ltd Or Equivalent As Approved, By Ge Fixed Or Laid/ Inserted To Timber/Gi/Aluminium Framework With Complete All As Specified And As Directed. 41 Taking Down Cement Mortar Plastering On Brick Or Stone Walls, Etc. Including Raking Out Joints,Hacking For Key,Scrubbing Down With Water, Etc Complete All As Specified And As Directed. 42 M&L For Rendering 15Mm (In Two Layers 10Mm+5Mm) Thick Plaster In Cm (1:4) On Faces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 43 M&L For Rendering 5Mm Thick Plaster In Cm (1:3) On Faces Of Brick Work Or Concrete On Surfaces Of Ceiling, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 44 Complete Removal Of Existing Treatment Including Washing Rubbing Down And Stopping Of Painted Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 45 M&L For New Plaster Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 46 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 47 M & L For Cement Concrete As Pcc 1:5:10 Type E-2 Using (40Mm Graded Stone Aggregate) As Foundations,Filling And Mass Concrete Complete All As Specified. 48 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 49 Demolition Of Brick Work Or Stone/Boulder Masonary, Laid In Cement Mortar Or Cement Lime Mortar Complete All As Specified. 50 M&L Brick Work, Straight Or Curved On Plan N.Exc 6M Mean Radius In Cm 1:6 Using Old Size Brick Complete All As Specified. 51 Taking Down Chowkat Or Frame With Shutters (With Out Taking Off Shutter From The Frame ) Not Exceeding 1.5 Sqm Each As Directed By Engineer-In-Charge. 52 S&F For Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door Frames/Chowkhat Comprising Of 100 Mm X 65 Mm Size, Applying Pvc Solvent Cement And Screwed With Full Body Threaded, Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg/Cum And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant And Fixed In Position With Mild Steel Hold Fast/Lugs/Ss Dash Fasteners Of Required Dia And Length Complete All As Specified And As Directed By Engr-In-Charge. 53 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Solid Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 54 S&F Stainless Steel (304 Grade) Finished Butt Hinges 125Mm Complete All As Specified And Directed 55 S & F Extruded Brass Handles, Fabricated Type Polished 150 Mm Complete All As Specified. 56 S & F Brass , Barrel Tower Bolts, With Cast Or Sheet Barrel And Rolled Or Cast Bolts And Fixed 200 Mm Complete All As Specified. 57 M&L For 250Mm Long Brass, Sliding Door Bolt Withsand Or Die-Cast Brass Hasp, Staple (Bolt Type) And Fixing Bolt With Rolled Or Drawn Brass Bolts And Fixed Complete All As Specified And As Directed. 58 Dismantling Pvc Pipes With Fittings Upto 75Mm To 110Mm Dia Complete All As Specified And Directed By Engr-In Charge.. 59 S&F For Pvc (Swr) Pipe 110 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 60 S&F For Pvc (Swr) Pipe 75 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 61 S&F For Pvc (Swr) Bends With Access Door 110 Mm Dia Complete All As Specified And As Directed. 62 All As Per Item No 61 Above But 75 Mm Dia. 63 S&F Pvc (Swr) Plain Bend 110 Mm Dia Complete All As Specified And As Directed. 64 S&F Pvc (Swr) Plain Bend 75 Mm Dia Complete All As Specified And As Directed. 65 S&F Pvc (Swr) Branch Piece Single Or Double T Equal Or Unequal With Access Door 110 Mm Dia Complete All As Specified And As Directed. 66 All As Per Item No 65 But 75 Mm Dia. 67 S&F Pvc (Swr) Vent Cowl 110 Mm Dia Complete All As Specified And As Directed. 68 Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering, And Removing Surplus Soil To A Distance N Exc 50 M And Making Good Surface 69 M&L For Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc. And Making Good, Cutting Not Exc 10 Cm Girth All As Specified. 70 Taking Down Carefully Existing Points Wiring On Surface Conduit/Concealed Conduit Including Conduit From Surface And Expect Conduit In Concealed Wiring For Light/Fan/Socket/Power/Bell From Wall & Roof Along With Fitting And Fixtures Such As Switches, Sockets, Ceiling Roses, Batten Holders, Unserviceable Light Fittings, Pieces Of Wires, Gutties, Conduit, Wooden Boards Etc Removing Materials To Store For Keeping In Safe Custody Of Contractor For Which The Credit Has Been Considered Under Schedule Of Credit And Making Good The Disturbed Portion Of All Floor, Ceiling Etc All As Specified And Directed. 71 M & L For Point Wiring With 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor For One Light/Fan/Bell Point In And Including New Pvc Rigid Non Metallic Concealed Conduit 19/20 Mm Dia, Medium Duty, Isi Marked To Be Terminated In Pressed Steel Terminal Boxes With Pvc Modular Top Cover Plates Of Suitable Size For Mounting Of Modular Type Switches/Sockets/Regulators Including 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Earth Continuity Conductor Controlled By One Switch And/Or One Regulator Complete Including Cutting Chases And Making Good The Surfaces In Cm 1:3 And Finishing The Surface As Per Existing Treatment All As Specified And Directed By Engr-In-Charge.Notes: (I) Cost Of Pressed Steel Terminal Boxes And Modular Top Cover Plate Shall Be Included In Point Wiring. (Ii) Wiring Shall Be Done As Per Colour Code In Is For Phase, Neutral And Earth.(Iii) -Cost Of Eye/Bottle Thimbles Used For Connection In Switches/Sockets & Mcbs In Dbs Shall Deemed To Be Included In The Unit Rate Quoted For This Item. 72 All As Per Sl Item No 71.00 Above Herein Before But One Socket Out Let 5 Pins 5 Amp On The Same Board With Other Switches Complete All As Specified And Directed. 73 All As Per Sl Item No 71.00 Above Herein Before But For One Socket Out Let 5 Pins 5 Amp On Independent Board Complete All As Specified And Directed. 74 All As Per Item No71.00 Herein Before But 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor Incl 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Copper Earth Wire For Switch Socket Combination 3 Pin 15 Amps On Independent Board. 75 S & F In Replacement Of Modular Switch 1 Way, 6 Amps, 1 Module, 230 Volts Complete All As Specified. 76 S & F In Replacement Of Modular Switch 1 Way, 16 Amps, 1 Module, 230 Volts Complete All As Specified. 77 S & F In Replacement Of Modular Socket 5 Pin 6 Amps, 2 Module 230 Volts Complete All As Specified. 78 S & F In Replacement Of Modular Socket 5 Pin 6 &16 Amps, Combination Type 2 Module Complete All As Specified. 79 S & F In Replacement Of Modular Fan Regulator Step Type, 120 Watts, 2 Module Complete Fixed As In Repair All As Specified. 80 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 81 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Green Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 82 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Red Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 83 Supply And Fix Surface/Recess Mounted Led Luminaire 36 Watt Cool White 4000-5000K Suitable For Gridd Celling Cutout Dimensions: 2X2 Ft. Incl Connecting With Twin Core Copper Wire From Ceiling Rose To Fitting, Fixture Size: (Lxwxh) In (595X595X65) Mm Incl Lamp And Driver All As Specified & Directed. 84 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 18/20W 6500K Of Capacity ,20 Watt,4 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 85 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 86 Supply And Fix Mirror Light With Linear & Compact 12 W Mirror Light With Decorative Grey End Caps, Polycarbonate Body And Ribbed Opal Diffuser Of Capacity 9 Watt Complete All As Specified And Directed By Engr-In-Charge. 87 M & L For Sub Main Wiring With Two Single Core 4.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 4 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2 Runs Of 4.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 4.00 Sqm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note2 : Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces, Cutting Not Exc. 10 Cm Girth . (Iii) Taking Out/Down Existing Unserviceable Sub Main Wiring. 88 Taking Down And Refixing Of Ceiling Fan After Supply And Replacement Of Rubber Reel, Round Cover Plate Of Size 6 Inch Of Ceiling Fan Complete With Ms Split Clamp Two Nos, Nuts And Bolts Complete All As Specified And Directed By Engr-In-Charge. 89 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 250 Mm Sweep 900 Rpm Engineering Thermoplastic Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Louver Complete All As Specified And Directed By Engineer-In-Charge. 90 Material And Labour For Making Hole Of Suitable Size For Exhaust Fan 250 Mm/ 300Mm Sweep In Wall For Grouting And Making Good The Surface Complete All As Specified And Directed By Engr-In-Charge. 91 Supply And Fixing Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With Mcb Spn 32 Amps, Complete All As Specified And As Directed By Engineer-In-Charge. 92 S&F Poly Coated Gi Frame Work As In Grid For False Ceiling Comprising Of Protected Gi Perimeter Channel 0.55 Mm Thick With Two Unequal Flanges Of 20 And 30Mm And Web Of 27Mm Fixed To Surrounding Wall Using Nylon Sleves And Screws At 450Mm Centre To Centre/Intermediate Chaqnnel 0.9Mm Thick Having To Equal Flanges Of 15Mm Each And Web Of 45 Mm Suspended From Soffit And Approx 900Mm Centre To Centre With Gi Cleat And Steel Expansion Fasterners With And Including Ceiling Section (Not Exc 1.2 Metre Length) Of 0.55Mm Thickness Having Kurled Web Of 50Mm And Flange Of 26Mm Each With Lips Of 10.5Mm Fixed To The Intermediate Channel With Connecting Clips Acorss The Intermediate Channel At 457Mm Centre To Centre And Hangers 6Mm Dia Gi (Upto 1200 Mm Length Adjusting Level Fixed To Roof Slabs By Means Of Ceiling Cleats Made Out Of Gi Flat 40 X3Mm Size 60Mm Long Complete With And Including 7Mm Thick Pvc Laminated Gypsum Tiles Of Size 595X595Mm Complete All As Specified & Directed 93 M&L For Complete Removal Of Existing Surfaces Of Walls Including Cornices, Pillasters Etc, And Applying Two Coats Of Obd Over And Incl A Coat Of Interior Wall Primer Over Wall Care Putty Complete All As Specified And Directed. 94 M&L For Complete Removal Of Existing Treatment On Walls And Applying 02 Coats Of Exterior Weather Emulsion Paint To External Walls/Rcc Surfaces/Soffits Of Chajjas/Roof Projections/Cantilevers/Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer And Over Wall Care Putty Complete All As Specified. 95 S&F Stainless Steel Tubing Of 25 Mm Dia Chromium Plated Min. 1.0 Mm Wall Thickness As In Curtain Rod Complete Incl S&F 02 Nos Stainless Steel Brackets/Finials Fency Type, Stops Fixed With Ss Screws Etc All As Specified & Directed.Note : For The Purpose Of Mesurement And Payment Running Length Of Curtain Rod Only Shall Be Considered. 96 Taking Down Chowkhats Or Frames Of Any Description Exc 1.5 Sqm And N. Exc. 4 Sqm Each (Without Taking Off Shutters From The Frame) Including Cutting Hole To Size For Receive Fresh Pcc Of Hold Fast And Making Good The Disturbed Surface Same Complete All As Specified And Directed. 97 S&F Factory Made Pressed Steel Frames Made Of Ms Sheet Of 1.20 Mm Thickness For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete As Specified,Size 125X60Mm 98 M&L Pcc 1:3:6 Type C-0 In 12.5 Mm Graded Stone Aggregates Hold Fast Fillinng Inside Frame & Hold Fasts Etc Complete All As Specified 99 S&F Factory Made Flush Shutters 35Mm Thick Ply Construction, Bwp Confirming To Is 2202, Solid Core Construction, With Block Board Core And Plywood Face Panels Commercial Type On Both Sides With 6Mm Thick Lipping Frame To Match Including Supply And Fixing Following Items :(A) Mild Steel Butt Hinges 125Mm - 3 Nos. Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos. Per Leaf(D) Stainless Steel (804 Grade) Finished Sliding Bolt 250 Mm - 1 No. Per Leaf(E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 100 S&F 35Mm Thick Glazed And Skelton Shutters Of 2Nd Class Hard Wood (Factory Made) Open Rebated And Divided To Receive Glass, Gauze Etc (Without Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass Etc Size Of Members Of Shutter As Specified In Ssr-91 Pt-1 Section 8 Clause 8.20(A), Kiln Seasoned And Chemically Pressure Treated All As Specified Including Stainless Steel 304 Grade Wire Cloth (0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm) All As Specified And Including Supply And Fixing Following Items :(A) Stainless Steel (304 Grade) Finished Butt Hinges 125Mm - 3 Nos Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos Per Leaf(D) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16X250Mm - 1 No Per Leaf (E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 101 M&L For Two Coat Of Synthetic Enamel Paint (Finishing Coat) Over One Coat Of Pink Primer To New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Incl Prepration Of Surfaces Complete All As Specified And Directed. 102 S&F 300Mm, Ordinary Rat Tail Rod Pattern Springs Including Roller And Roller Plate Complete All As Specified And Directed. 103 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 104 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X35 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 105 S & F In Replacement Of Surface Mounted Led Bulk Head Luminaire Of Capacity 10 Watt With Abs Body & Polycarbonate Diffuser, Ip54 Inc Connection With ,With Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 106 Supply And Fix Lamp Holder Including Led Bulb 9 W Including Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 107 M & L For Sub Main Wiring With Two Single Core 6.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 6.0 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2(Two) Runs Of 6.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 6.00 Sqmm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note 2 :(I) Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces And Cutting Not Exc. 10 Cm Girth . (Iii) Including Taking Out/Down Existing Unserviceable Sub Main Wiring. 108 S & F In Replacement Of Sheet Metal Enclosure Db Tpn 4 Ways Double Door 415 Volts With 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables Complete With Ip-43 Protection Complete All As Specified And Directed By Engr-In-Charge 109 S & F In Replacement Of Mcb, Triple Pole & Neutral (Tpn) 10 Ka 240 Volts 40 To 63 Amp Capacity Fixing In Db’S Complete All As Specified And Directed. (Note: Mcb Should Be B Or C Curve As Directed By Engineer In Charge) 110 Supply And Fix In Replacement Of Sheet Metal Enclosure 8 Ways Double Door For Dbs When Mcbs Are To Be Used 240,Volts Including 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link All Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables With Ip43 Protection Complete All As Specified & Directed By Engr-In-Charge. 111 S & F In Replacement Of Mcb, Single Pole 240 Volts 6 To 32 Amp Capacity For Fixing In Db’S Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 112 Supply And Fix In Replacement Of Mcb , Spn, 240 Volts ,40-63 Amp For Fixing In Dbs Of Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 113 M & L In Replacement Of Unsv Earthing Complete With Galvanized Iron Earth Plate Electrode Of Size 600X600X6.0Mm , Buried Directly In Ground (Earth Pit Not Less Than 2.25 Mtrs Below Normal Ground Level) With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected To Galvanized Earth Lead Wire 4.0 Mm Dia By Means Of Bolts , Nuts , Check Nuts And Galvanized Iron Or Steel Including Earth Work In Any Type Of Soil, Charcoal Salt 15 Cm Around The Earth Plate 20 Mm Dia Watering Pipe Medium Grade 1.70 Mtr Long With A Plug At Top, Gi Protection Pipe Light Grade 15 Mm Dia From Earth Pit To Main Board Including Pcc Pit In Cement Concrete 1:2:4 Along With Ci Frame And Cover 10Mm Thick Duly Hinged To Ci Frame As Shown In The Electrical Plate No3 Of Ssr 2009 Part 1 Specification At Page 497. 114 Xlpe Insulated ,Screened, Pvc Bedded, Galvanized Steel Wire Armoured, Electric Power Cables (Heavy Duty) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 25 Sq Mm 4 Core Supplied & Laid In Replacement Complete All As Specified& Directed By Engineer-In-Charge. 115 Excavation In Trenches Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5 Mtr In Depth For Laying Of Cables Including Getting Out In Any Kind Of Soil Complete All As Specified And Directed. 116 Returning Filling In Including Spreading, Levelling, And Well Ramming, In Layers Not Exceeding 25 Cm Each Layer Of Any Kind Of Soil. 117 Removing Surplus Excavated Material From Site Not Exceeding 50 Mtrs From Starting Point And Depositing Where Directed At Level Not Exceeding 1.5 Mtr Above The Starting Point. 118 Material And Labour For Sand Cushioning For Cables 8 Cm Below The Cable And 15 Cm Above With Dry River Sand In Trenches For Cushioning Of Underground Cable Line Including Spreading, Leveling, Well Ramming Completed All As Specified And Directed. 119 Cutting Of Hardstanding Floor/Wall For Laying Of Cable Including Matching With Suface By Using Cement Concrete All As Specified And Directed. 120 Supplying & Laying Factory Made Unreinforced Precast Concrete Cable Covers Class Lv Type 1, Flat, Size 250X150X40Mm Laid In Trenches As Protection To Cables Complete All As Directed By Engr-In-Charge 121 Material And Labour For Replacement Of Gi Tubing Light Grade 40 Mm Bore For Passing Through Cables Under The Floor ,Along The Wall Or Along The Pole Complete All As Specified And Directed. 122 Dismantling Of Stone Slab And Tiles Laid Bedded And Pointed In Any Mortar Description Or Thickness In Floors, Apron Etc Complete All As Specified. 123 M & L For Screed Bed Or Bedding Layer Of Mortar 15 Mm Thick In Cm 1:6 For Laying Floor Finishes Complete All As Specified. 124 M&L For Virified Ceramic Light Shade Tiles 8 - 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc,Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Epoxy Cartridge Tile Grout Using Fill The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour. 125 All As Per Item No 124 But As A Skirting Incl. 10Mm Thick Rendering As In Back Coat Complete All As Specified. 126 M&L For 7 To 8 Mm Ant-Skid Ceramic Joint Free Premium Quality Coloured Tiles Area Of Each Tile Esc 0.06 Spm But Next 0.11Sqm, As In Floors Etc. In Any Pattern Ghe & Dark Tiles As Approved, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, In Floors Etc. Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 127 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Laid Over Cement Screed Base 15Mm Thick In Cm 1:6 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 128 Rounding To Edges Of Stone Slabs One Edge, Such As In Steps, Cooking Platform, And Other Similar Situations All As Specified. 129 Dismantling Water Tanks And Removing To Store Of Capacity Exc 500 & Not Exc 1000 Ltrs Complete All As Specified. 130 Supply And And Fixing, Hoisting Pvc Tank Of 1000 Ltr Capacity Including Supplied And Fixed 20Mm Dia Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed.(Minimum Weight 15Mm-142 Gms/20Mm-210Gms/25Mm-455 Gms/40Mm-690 Gms Float Valve Assembly Complete All As Specified And Directed. 131 S&F In Repair Wall Mixture Mixing Valves Incl. Three Joints To Steel Pipes Or Unions 15 Mm Bore Fancy Type Best Quality As Per Sample Approved By Ge Make-Jaquar Cat Part No Qqp-7217Pm Or Equivalent In Hindware/Kohlar. 132 S&F Pvc Cabinet 600X450Mm Overall Size With Looking Mirror Of Selected Qality Glass Mountedover Pvc Framing As Per Sample Complete Fixed In Repair Complete All As Specified. 133 S&F Stainless Steel Plate Rack Of Size Not Less Than 90Cmx75Cm(Wt N. Less Than 4 Kg) Fixed With Stainless Steel Screw Including Taking Out Old Unserviceable Wooden Plate Rack As Approved By Ge Complete All As Specified. 134 S&F In Repairs Chromium Plated Shower Roses With Swivel Joints 125 Mm Dia Size Incl Fixing To Gi Pipe/Union Fixed Make-Jaquar /Hindware/Kohlar. 135 M & L For Rendering 15 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:6 Finished Even And Smooth ( Without Using Extra Cement ) With Sagol Finish On Plastered Surface Complete All As Specified And As Directed. 136 M&L For Preparation Of New Decorated Plastered Or Unplastered Surfaces Of Walls And Applying Two Coats Of Exterior Emulsion Over One Coat Of Primer And Over 2Mm Thick Putty For Levelling And Smoothening, Complete All As Specified And Directed. 137 M&L Preparation Of New Plastered Surface Of Walls And Applying Two Coats Of Oil Bound Distemper Over 1.5Mm Thick Wall Care Putty Complete All As Specified And Directed. 138 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 139 S&F Sinks With Drainage Board Made Of Stainless Steel Lmm Thickkitchen Or Laboratory With Plugs,Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X 460Mm Bowl Size 410Mm X 330Mm X 160Mm Complete All As Specified And Directed. 140 S&F In Repair Brass Chromium Plated Sink Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar /Hindware/Kohlar 141 S&F Powder Coated Anodised Aluminium Frame For Doors, Windows Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified And Directed. 142 S&F Frosted Glass 4.00Mm Thick Ordinary Quality And Glazing With Oil Putty In Square N.Exc 0.50Sqm In Each Panes Complete All As Specified And Directed. 143 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Sketon/Glased Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 144 S&F Factory Made Wpc Extruded Board Cnc Machine Cut Jali Fixed To Skelton Door As Per Approved Design Complete All As Specified And Directed 145 S&F Kitchen Cabinets Including All Fittings And Fixtures Incl The Follwing. (A) 19Mm Thick Plywood Of Commercial Block Board,Make: Kitply/Century Ply/ Green Ply(B) 1Mm Thick Commerical Lamination On Both Side Fixed To Black Board(Colour And Design As Approved)(C) Ss Pullout Basket Ss Finish Of Plain 15 X 20 X 6 (D) D Type Handle 100Mm Ss Finish(E) Pullout Basket Ss Finish Cutlery Wire Of Size 15X20X4 (F) 2Nd Class Hard As In Frame Work(G)Ss Channels For Pullout Basket As Required. (Note:- The Measurement Shall Be Taken From Front Elevation And Not Girthwise. 146 S&F Factory Made Upvc Brown Colour Door Shutter Made Of Extruded Profile With Wall Thickness Of 2.3Mm(+-0.2Mm) Door Profile With Hollow Section With Multy Chamber. Frame (60X62Mm),Sash(42Mmx67Mm).Sliding Interlock(One Verticle Length In Each Shutter)(45.5Mmx28Mm).Glazing Bead(24.5Mmx16Mm)Will Be Mittred Cut And Fusion Welded At All Corner.Including Drilling Holes For Fixing Hardware And Drainge Of Water Etc Am,.Making Arrangement For Fixing Of Hardware.Epdm Gasket,1.2+0.2 Mm Thick Galvanised Steel Frame(30Mmx21.5Mm).Sash (30Mmx18Mm)Profile To Be Inserted In Required Profile.Frame Will Be Finshed To The Wall With 8Mmx100Mm Long Fasteners.Hardware Touch Lockof Zinc Alloyed(Brown Powder Coated)Steel Roller System Including 5Mm Thick Glazing With Selected Quality Glass ,Aluminium Track And Bottom Rail For Two Track Sliding Fram,Wool Pine For Sliding Sash And Interlock. Note.The Unit Rate Coated By Contractor Includes Cost Of Glass And All Other Conncted Accessories,Net Opening Will Be Measured For Purpose.Make:H2O Window,Fenesta,Anuplast As Approved By Ge. 147 M&L For Rcc 1:2:4 Type B-1 Using 20Mm Graded Crushed Stone Aggregate In Any Situation Except Foundation Complete All As Specified And Directed. 148 S&F 10Mm Dia And Above Tmt Bars Cut To Length, Bend To Shape As Required Including Cranking, Hooking Ends & Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Complete All As Specified And Directd. 149 All As Item No 77 Here In Before But 5Mm Dia And Over Upto & Including 10Mm Dia In Stirrups, Spaces & Binder Complete All As Specified And Directd. 150 S & F Powder Coated Aluminium Window/Ventilator Shutters, Side Hung Type With Sash Bars, Including Necessay Joinery Cleats, Glazing Clips, Rubber Packing, Chowkats Aluminium Snap Beading, Screws, Suitable Handle Etc With And Including Sheet Glass Or Ordinary Glazing Quality Of 4Mm Thick And Incl Gi Wire Mesh 0.56 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18 Mm , Size Of Side Rails , Top Rails , Bottom Rail 85X44.5Mm And Size Of Chowkat Frame 101.6X44.45Mm And Thickness Of Aluminium Member Shall Be 1.40Mm Thick Complete All As Specified. 151 S&F For Prelaminated Particle Board 18/19 Mm Interior Grade Prelaminated On One Side With Decorative Choice Lamination And Other Side Balancing White Lamination Fixed With Screw Timber Frame Work Including Dismantling Board All As Specified. 152 S&F In Repair Continuous (Paino) Hinges, Mild Steel, Bright Finish Or Electrogalvanised Width Of Flap (When Open) In 40Mm All As Specified. 153 S&F In Repair 40Mm Dia, Cupboard Knobs Fixed With Nut, Screw And Washer Of Mild Steel Bright Finished All As Specified. 154 S&F Ball Catches With 8Mm Dia Steel Ball And Brass Body And Striking Plate Including Letting In And Fixing Complete All As Specified. 155 Supply & Fix In Replacement Of Modular Bell Push Switch 1 Way, 6 Amps, 1 Module Complete All As Specified. 156 Supply & Fix In Replacement Of Call Bell Ding Dong Ac 230 Volt Single Pole Complete All As Specified. 157 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 300 Mm Sweep 900 Rpm Metal Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Hole Making Louver Complete All As Specified And Directed By Engineer-In-Charge. 158 S & F Modern Energy Efficient Bedroom Muziris Wall Decorative Light Of Capacity 20 Watt Single Headed 240 Volt, Ip20 Rating, Controller Type (Push Button), Product Weight 1.04 Kg, Body Material (Metal), Power Source (Corded Electric),Lamp Base E27, Colour(Bronze) Incl Electrically Connection , Including Removing Of Unserviceable Decorative Light Fittings Of Any Description Complete All As Specified And Directed By Engr-In-Charge. Make: Philips Model No 31425 Or As Equivalent. 159 Excavating In Trenches N Exc 1.50M In Width And N Exc 1.50M In Depth For Foundation, Manholes Etc As Well As N Exc 10 Sqm On Plan Area And Getting Out In Soft/Loose Soil All As Specified And Directed. 160 M&L For Pcc 1:5:10 Type E-2, Using 40Mm Graded Crushed Stone Aggregate In Foundation, Filling And Mass Concrete All As Specified And Directed. 161 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 162 S&F Mild Steel Deformed Bars, 6Mm To 8Mm Dia Cut To Length, Bent To Shape Required Including Cranking And Binding With & Including Mild Steel Wire (Annealed) Not Less Than 0-.90Mm Dia Complete. 163 M&L For Form Work To Soffits Of Suspended Slabs Such As Roof Slabs Etc For Rough Finished Concrete Surface Complete All As Specified And Directed. 164 M&L For Form Work To Sides For Slabs And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10 Cm But N Exc 20 Cm Wide For Fair Finished Concrete Surface Complete All As Specified And Directed. 165 Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams And Similar Work, Vertical Or To Batter For Rough Finished Flat Surfaces Of Concrete. 166 Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions, Square, Rectangular Or Polygonal For Rough Finished Flat Surfaces Of Concrete. 167 M&L For Rendering In Cement Mortar (1:6) 10 Mm Thick Finished Even Smooth Complete All As Specified On Brick Or Concrete Surface Of Fair Faces. 168 M&L 15Mm Thick Cement Plaster In Two Layer First Coat In Cm 1:6,10Cm Thick & Second Layer 5Mm Thick In Cm 1:4 Mixed With Wpc 3% By Weight Of Cement Including Finishing Fair & Even On Brick Or Concrete Surfaces Of Othern Than Fair Faces. 169 M&L For 5Mm Thick Cement Plastering To Rcc Surfaces In Cm :1:3) Finished Even And Smooth W/O Using Extra Cement On Ceiling Surfaces. 170 S&F Stainless Steel Butt Hinges Medium Weight Cold Rolled Isi Marked Of Size 100 Mm Complete All As Specified And Directed. 171 M&L For Ms Framed Guard Bars Conforming To Fe-410-0 Or Fe-310-0 Welded To Steel Windows/Ventilations Complete All As Specified And Directed. 172 S&F Vitrous China Squatting Pan Of Orissa Patterns Long Pan Size 580Mx440Mm White With P Or S Trap Front Of Back Inlet And Foot Rest Including Long Band Any Pattern (Excluding Flushing Cistern And Flush Pipe) Including Provision For Lime Concrete Bedding. 173 S&F Pvc Flushing Cistern Low Level 10 Ltr Cap With Inlet Ball Valve Float And Handle Syphonic Action Type Incl Brackets And Flush Pipe Of Polythene Of Low Or High Density Isi Marked. 174 S & F In Repairs Vitreous China Oval Shape Wash Basin, White, Flat Back, Size 580 X 450 Mm Excluding Taps, Waste, Chain And Plug And Porcelain Stopper But Including Brackets With 32 Mm Dia Waste Fittings, Brass, Chromium Plated With Waste Pipe Complete All As Specified. 175 S&F Looking Mirror Of Selected Quality Mounted On 6 Mm Thick Ply And Fixed To Wall With Wooden Plugs Chromium Plated Brass Screws And Washers. 176 S&F For Ci Floor Trap With Incl Jointing With Waste Pipe In Cement Mortar Of Size 100Mm. 177 S&F Gully Trap Stone Ware Square Of Round Mounted Type P Of Size 150X150Mm. 178 S&F 20Mm Dia Stop Valve Of Copper Alloy Screwed Down High Pressure With Crutch Or Butter Fly Handle Screwed On Both Ends For Iron Pipe Or For Union Fixed. 179 S&F Pvc Connection 15Mm Dia 600Mm Long Of Heavy Grade Screwed One End To Inlet Of Whb/Pillar Tap/Cistern Etc Complete Incl Brass Union Coupling On Both Ends Connfirming To Is-3076 Complete With Connector For Connection Old Water. 180 S& F For Ci Pipe 75Mm Dia Laid In Floor In Any Length With Or Without Cars With Cement Joint (Waste & Vent Pipe). 181 All As Per Item No 38 Here In Before But 100Mm Dia. 182 S&F For Ci Bend Any Radius Disminshing Pieces Or Tyes Of 100Mm Bore With Ducks For Or Head Rest. 183 S&F For Ci Branch Pieces Single Equal Or Unequal Ordinary Or Inverted Or With Paralled Brnach 100 Mm Bore. 184 S&F Cast Iron Sand Cast Pipe 100 Mm Dia With Or Without Cars With Cement Joint Fixed To Walls. 185 S&F Cast Iron 100 Mm Cowl. 186 M&L For Pcc 1:4:8 Type D-2 Using 40Mm Graded Stone Aggregate)75Mm Thick On In Sub Base Of Fllor .. 187 M&L For 15Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And Directd. 188 M&L For Coloured Glazed Ceramic Tiles On Vertical Surface (300Mmx600Mx7M) Thick Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 189 M&L For Coloured Non Skid Ceramic(300X300Mm) Tiles 7 To 8Mm Thick As In Floor Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 190 S&F Steel Ventilation With Top Hung Shutter Including Hinges, Steel Peg Stay Complete. 191 S&F 4Mm Thick Sheet Glass Of Figured,Pin Headed And Glazing With Oil Putty In Square N Exc 0.50 Sqm In Each. 192 M&L For Preparation Of Newly Steel Surfaces And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Over 10 Cm Width Or Girth Complete All As Specified And Directd. 193 M&L For Preparation Of Newly Plastered Surfaces And Applying Two Coats Of Cement Base Paint Over A Coat Of Chalk Whiting Complete All As Specified And Directd. 194 M&L For Three Coats Of White Wash On Wall Of Newly Plastered Surface. 195 S&F For Preparation Of Newly Plastered Surfaces And Applying Three Coats Of White Wash On Ceiling. 196 M & L For Factory Made Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And As Directed. 197 S&F Factory Made Solid Pvc Moulded Door Shutter, With Particle Board Core, 28 To 30Mm Thick (Stiles), With 2, 4, Or 6 Raised Panel Design With 2Mm Thick Moulded Pvc Sheet On The Front Face & 2Mm Plain Colour Pvc Sheet On Back Face & 5Mm Thick Plain Colour Pvc Sheet On Back Face, Supplying & Fixing In Frame At Site As Per Specification & Drawing All As Specified. 198 S&F Aluminium Tower Bolt 150Mm Long Stove Enamelled Black With Bright Bolt & Fixed. 199 S&F Aluminium Sliding Door Bolt With Hasp And Staples Type Bolt Type , 300Mm Long Stove Enamelled And Fixing Clips Of Sheet Cast Or Extruded Section Or Cast Aluminium Alloy And Fixed All As Specified. 200 S&F Aluminium Alloy Handle Of 100M Size Oval Type Stove Enamelled & Fixed All As Specified. 201 M&L For Rendering 10Mm Thick Cm (1:4) On Roof Slab Top, Mixed With Water Proofing Liquid Finished Even And Fair Without Using Extra Cement Complete All As Specified. Note: Water Proofing Liquid Shall Be Measured And Paid Separately. 202 M & L For Cleaning The Newly Plastered Surfaces Of Concrete ( Roof Etc) With Wire Brushes And Applying Water Proofing Treatment As Under :-I) Apply One Coat Of Oil Bound Bituminous Primer @ 0.25 Kg/Sq.M Ii) Providing And Laying 3 Mm Thick App Modified Water Proofing Membrane Weighing Not Less Than 3.5 Kg / Sqm Reinforced With Non Woven Polyester Mat Weighing Not Less Than 160 Gm/Sqm All As Specified Procured From Any One Of The Approved ManufacturerS Iii) Apply One Coat Of Solar Reflective Bituminous Aluminium Paint @ 0.15 Kg/Sqm Over Membrane Over Non Assesble Roof Surfaces Complete All As Per ManufacturerS Instructions And As Directed . 203 M/L Brick Work In Cm1:4, In Half Brick Thick Wall. 204 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 205 S/F Vitreous China Toilet Paper Holder Fixed To Walls With Chromium Plated Cp) Brass Screws 206 S/F Vitreous China Soap Dish Of Appx Size 160*160*90Mm Any Type Fixed To Plugs With Chromium Plated Brass Screws 207 S/F Sheet Glass Shelf Assembly Consistig Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Brackets Guard And Railing 60Cm Long 208 S & F Brass Chromium Plated Tubular Towel Rail, 20 Mm Dia, D Type, 60 Cm Long Between Flanges Complete All As Specified. 209 M & L For Granite 20 Mm Thick Machine Cut, Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Griding And Polishing Types All As Specified. 210 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 211 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 212 S&F Health Faucet Including Ms/Anodised Hanging Device Fixed Complete All As Specified And As Directed. 213 Surface Excavation Not Exceeding 30Cm Deep And Averaging 15Cm Deep And Getting Out In Loose / Soft Soil All As Specified And Directed. 214 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 215 M & L 100Mm Thick Pcc 1: 4: 8 Type D2 (Using 40Mm Graded Stone Aggregate) As In Sub Base Complete All As Specified And Directed. 216 M&L For Machine Pressed Precast Concrete Interlocking Paver Block Rubber Moulded Any Shape And Size Confirming To Is 15658-2006 Of 60Mm Thickness, M-35 Grade With Grey And Pigment As In Floor/Pavement Complete All As Specified And As Directed. 217 M&L For Providing Precast Concrete Type C-1, 1:2:4(Using 20Mm Graded Stone Aggregate) As In Kerb Blocks With Plain Fiar Faces, Including Chamferes, Weathering, Throating Etc And Setting In Mortar 1:4 Complete With Joints To Match. 218 M&L For Cement Concrete Type 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundations, Filling And Mass Concrete Complete All As Specified And As Directed. 219 M & L For Sand Filling Under Floors Or In Foundation Including Watering And Consolidation 220 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X25 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 221 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 222 M&L For Boring Of Holes Under Road, Pavement, Hard Standing By Trench-Less Technology Using Ultrasound Technique And Necessary Machine Suitable To Pass Through 40 To 80 Mm Bore Gi Tubing And Cable Etc Complete All As Specified And Directed.Note: Gi Pipe Shall Be Measured And Paid Seperately Under Relevant Item.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
2.
Defence #11405410 Technical Bid
Tender for Taking Down Cement Plaster On Brick Or Stone Walls, Etc., Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed. , Demolition Of Brick Work Or Stone/Boulder Masonry, Built In Cement Mortar Including All Quoins,Arches, Pillars, Etc But Excluding Ashlar Facing, Dressed Stonework And Precast Concrete Articles Complete All As Specified And As Directed By Engineer-In-Charge. , M&L Brick Work With Sub-Class ‘B Bricks (With Old Size Bricks), Straight Or Curved On Plan Exc. 6.0 Metre Mean Radius, Built In Cement Mortar (1:6) Complete All As Specified And As Directed. , M&L For Half Brick Work Burnt Modular Bricks Built In Cement Mortar (1:4) Straight Or Curved On Plan Exceeding 6Mtr Mean Radius And Complete All As Specified And As Directed. , M & L For Plain Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Aggreagte As In Coping Bed Block Etc Complete All As Specified And Complete All As Specified And As Directed. , M&L Plain Cement Concrete In Surface Channels,Benching In Sewers,Drains Etc Type B1 (1:2:4) Using 20 Mm Graded Stone Aggregate Complete All As Specified And As Directed. , M & L For Redndering In Cement Mortar (1:4) 15Mm Thick On Concrete /Brick Masonry Wall Surfaces, Complete All As Specified And As Directed.. (Note Wpc Paid Separetely) , M&L Pre-Cast Reinforced Cement Concrete (1:2:4) (20Mm Graded Aggregate) In Cover Slab Of Manholes, Septic Tanks, Etc., Set In Cement Mortar 1:4 Including Demolition Of Existing Reinforced Cement Concrete Slabs ., Complete All As Specified And As Directed. Note : Reinforcement Will Be Measured And Paid Separately Under Appropriate Items. , M&L Tmt Bars 10Mm Dia And Overcut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping For Columns Hooking Ends And Binding With And Including Mild Steel Wire (Annealed) Not Less Than 0.90Mm Dia, Complete All As Specified And As Directed. , M&L Two Coats Of Cement Base Paint Over A Coat Of Primer On New Wall Surface Including Preparation Of Surface. Complete All As Specified And As Directed. , M&L Preparation Of Old Surface Of Wall And Applying One Coat Of Cement Base Paint Complete All As Specified And As Directed. , Dismantling Plain Or Corrugated Asbestos Sheeting Any Thickness In Roof Covering. Complete All As Specified And As Directed. , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering Fixed With Self Tapping Screws Complete All As Specified And As Directed.. , Taking Down/Dismantlinig Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Proveded Complete All As Specified And As Directed. , S&F Rolled Sections As In Main And Cross Beams, Hip And Jack Rafters; Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates To Fe-290 (Gde E- 165) Complete All As Specified And As Directed. , Dismantling Posts Or Struts (Wood, Steel Or R.C.C.) Any Section, Including Taking Out Embedded Portion & Making Good Disturbed Ground Embedded In Concrete, Brick Work, Masonry, Etc. Complete All As Specified And As Directed. , Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In & Raming Earth/ Broken Rubble Mixed With Earth Around, In Layers N. Exc. 25Cm, Watering, & Removing Surplus Soil To A Distance N Exc 50M & Making Good Surface In Soft/Loose Soil. Complete All As Specified And As Directed. , M&L Plain Cement Concrete In Foundations, Filling And Mass-Concrete Type B2 (1:2:4) Using 40 Mm Graded Stone Aggregate Complete All As Specified And As Directed. , M&L For Ms Work For Fencing Post And Struts Made From Angle Iron And Flat Iron In Any Section Including Cutting Tops To Shape , Drilling Holes And Notching For Fixing Of Wires Etc Confirming To Fe -290 Or Fe -330, With And Incl Necessary Nut And Bolts Of 12Mm Dia Of Reqd Length Complete All As Specified And As Directed. , M&L, Ms Round Bars 10 Mm Dia And Over Cut To Length, Bent To Shape Reqd Incl Cranking Bending Etc And Binding With Ms Wire (Annealed) Not Less Than 0.9 Mm Dia As In Chain Link Fencing Fixing Fe-410-W (Gde.E-250) Quality-A Orfe 290 (Gde -E-165) Complete All As Specified And As Directed. , Preparing Steel Surfaces By Mechanical Cleaning/Sand Blasting And Applying One Coat Zinc Rich Epoxy Primer And Two Coats Aliphatic Two Component Polyurethane Paint Complete All As Per ManufacturerS Instruction And Complete All As Specified And As Directed. , Applying Two Coats Of Synthetic Enamel Paint On Steel & Iron Surfaces Of Any Description, Not Otherwise, Described, Over 10Cm Width Or Girth Including Preparation Of New Surface & Applying One Coat Of Red Oxide, Zinc Chrome Complete All As Specified And As Directed. , All As Per Item No Above Herein Before But Not Exceeding 10Cm Wide Or Girth. Complete All As Specified And As Directed. , M&L For Mild Steel Work For Securing Of Chain Link Fencing And Similar Small Articles Etc Confirming To Is-15911 Complete All As Specified And Directed. , S & F Ms Screw Bolts 5 To 10Mm Dia (Machine Made) With Hexagonal Or Square Head At One End, Screwed End To Be Fitted With Washer And One Hexagonal / Square Nuts And 5 To 10 Cm Long All As Specified And Directed. , S&F In Repairs For Galvanised 2 Strand Steel Barbed Wire 2.24Mm Dia Barbed With 2Mm Dia Barbs At 75Mm Spacing And Straining And Fixing To Any Type Of Standard Rails Straining Bolts Including Securing Or Tying At Cross With And Provision Of Galvanised Mild Steel Wire, Staples Or Steel Pins Etc Complete All As Specified And As Directed. (Each Line To Be Measured Separately) , Dismantling Fencing Wire Mesh, Any Type All Directed By Engineer-In-Charge Complete All As Specified And As Directed. , Fixing Only Chain Link Fencing Including Line Wires, Any Mesh, Size And Type To Any Type Of Standards, Rails, Straining Bolts, Etc.Including Provission Of Binding Wire Complete All As Specified And As Directed. , Supply Only Chain Link Ms Galvanisd Fencing, Any Size Or Type Complete All As Specified And As Directed. , M&L For Reinforced Cement Concrete Work (1:1.5:3) (20 Mm Graded Stone Aggregate )As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams,Bases For Columns Including Demolition Of Existing Reinforced Cement Concrete Complete All As Specified And As Directed. , M&L For Reinforced Cement Concrete Work (1:1.5:3) (20 Mm Graded Stone Aggregate) Columns, Pillars, Piers, Posts And Struts Including Demolition Of Existing Reinforced Cement Concrete Complete All As Specified And As Directed , M&L Formwork To Sides Of Concrete Foundations, Footings, Bases Ofcolumns, Raft And Raft Beams,Sides And Soffits (If Any) Of Foundation And Plinth Beams;And Similar Work; Vertical Or To Batter Flat Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed. , M&L Formwork To Formwork To Sides Of Pillars,Posts, Struts, Piers, Columns And Stanchions Square, Circular Rectangular Or Polygonal Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed. , Mild Steel Tmt Bar 10Mm Dia And Over Cut To Length Bent To Shape Required Including Cranking, Bending Spirally For Hoping For Columns Hooking Ends And Binding With & Including Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And As Directed. , Mild Steel Tmt Bar 5Mm Dia And Over Upto And Including 10Mm Dia As In Stirrups, Spacers & Binders Cut To Length Bent To Shape Required Including Cranking, Bending Spirally For Hoping For Columns Hooking Ends And Binding With & Including Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And As Directed. , S&F For Ms Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) And Hanging; Also Fastening And Fixing Confirming To Fe 410,E-250 Qualitry A Including Dismantling Wrought Or Mild Steel Work Of Any Description Not Otherwise Provided For Complete All As Specified And As Directed. , M& L For Granite Of Any Type 18-20Mm Thick Cut Beded And Jointed With Grey Cement Slurry And Pointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Grinding And Polishing Complete In Vertical Surfaces Of Wall Incl 10 Mm Thick Backing Coat In Cm 1:4 Including Demolition Of Stone Slabs Tiles Of Any Description Or Thickness In Floors Aprons Laid Bedeed And Pointed In Any Morter And Any Position. Complete All As Specified And As Directed. , Demolition Of Un- Reinforced Cement Concrete In Ground Floors And Pavings Not Exceeding 15 Cm Thickness. (Below Or Above Ground Level) Complete All As Specified And As Directed. , M&L For 100 Mm Thick Plain Cement Concrete (1:3:6) Type D-2 Using 40Mm Graded Stone Aggregate As In Subbase/Footpath Necessary Form Work, Complete All As Specified And As Directed. , M&L For 75 Mm Thick Plain Cement Concrete (1:3:6) Type D-2 Using 40Mm Graded Stone Aggregate As In Subbase/Footpath/Plinth Protection Necessary Form Work, Complete All As Specified And As Directed. , M&L For 50 Mm Thick Plain Cement Concrete (1:3:6) Type D-2 Using 20Mm Graded Stone Aggregate As In Subbase/Footpath Necessary Form Work, Complete All As Specified And As Directed. , M&L For Providing And Laying 60Mm Thick Factory Made Chamfered Edge Cement Concrete Paver Block Of M-35 Grade With Approved Colour, Design & Pattern As In Footparth, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc., Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compacted Bed Of Fine Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Incl Demolition Of Old Paver Block, Complete All As Specified And As Directed. , M&L For Pre-Polished Glazed Designer Endura Tiles/Dura Stone, Coloured, 30Cm X 30Cm X 10Cm Thick , Set, Jointed And Pointed In Neat Cement Slurry, Pointed In White Or Coloured Cement To Match In Floors Over 15Mm Thick Screed In 1:4 Including Dismantling Of Old Tiles Complete All As Specified And As Directed. , M&L Heavy Duty Coloured Ceramic Tiles As In Steps,Stairs In Single Piece Set And Jointed In Neat Cement Slurry And Pointed In White Cement Mixed With Pigment To Match The Colour Of Tiles Over And Including 15 Mm Thick Screed Bed Or Bedding Layer In Cm (1:4) Including Dismantling Of Old Heavy Duty Tiles, Complete All As Specified And As Directed By Engr-In-Charge , S&F In Repair 450Mm Bore Reinforced Concrete Pipes, Class Np2, Laid And Jointed Complete With Collars Including Dismantling Of Cast Iron Or Reinforced Concrete Drain Pipes, Jointed In Cement Mortar And Taking Out Of Trenches,Inclunding Concrete Bed In Plain Cement Concrete (1:3:6) Packing Under, & Haunching Against The Sides Of Pipes After They Are Laid & Tested Complete All As Specified And As Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 10
3.
Heavy Industries and Public Enterprises #11321092 Technical Bid
Tender For Civil And Mep Works For Setting Up Hindlabs Minor Lab, Barpeta, Assam- 1 Civil Works 2 Solid Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Etc Complete 3 12 Mm Cement Plaster Of Mix:1:6 (1 Cement : 6 Fine Sand). 4 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 5 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 6 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 7 Providing And Laying Premiumvitrified Tiles In Floor In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier,Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt/Antiskid Finish Of Size Size Of Tile 600 X 1200 Mm 8 Providing And Laying Premium Vitrified Wall Tile In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600 X 1200 Mm 9 Providing And Fixing Fiber Glass Reinforced Plastic (Frp) Door Frames Of Cross- Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15 Mm To Receive Shutter Of 30 Mm Thickness. The Laminated Shall Be Moulded With Fire Resistant Grade Unsaturated Polyester Resin And Chopped Mat. Door Frame Laminate Shall Be 2 Mm Thick And Shall Be Filled With Suitable Wooden Block In All The Three Legs. The Frame Shall Be Covered With Fiber Glass From All Sides. M.S. Stay Shall Be Provided At The Bottom To Steady The Frame. 10 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 11 Providing And Fixing To Existing Door Frames.30 Mm Thick Fiberglass Reinforced Plastic (F.R.P) Flush Door Shutter In Different Plain And Wood Finish Made With Fire Retardant Grade Unsaturated Polyester Resin, Moulded To 3 Mm Thick Frp Laminate All Around, With Suitable Wooden Blocks Inside At Required Places For Fixing Of Fittings And Polyurethane Foam (Puf) / Polystyrene Foam To Be Used All Filler Material Throughout The Hollow Panel, Casted Monoolithically With Testing Parameters Of F.R.P. Laminate Conforming To Table - 3 Of Is : 14856, Complete As Per Direction Of Engineer- In-Charge. 12 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 13 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 14 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 15 Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm,With Swan Neck Faucet With Pipe In Let And Drain Provision, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:Kitchen Sink With Drain Board510X1040 Mm Bowl Depth 250 Mm 16 Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms 17 Providing And Fixing Cp Towel Rod Complete Fixed With Cp Brass Screws Of Approved Quality Of Minimum 600Mm Length Approved As Per The Requirement Of Engineer In Charge. 18 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions: 45 Cm Length15 Mm Nominal Bore 19 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 40 Mm Dia 20 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 21 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 10Kgf/Cm2 22 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work,Including Cutting Chased And Making Good The Wall Etc. 20 Mm Pipe 12 Kgf/Cm2 23 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall 24 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clips/ At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 110 Mm Dia 6 Kgf/Cm2 - External Work- Exposed On Wall 25 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia 45 Degree Elbow 26 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75X75X75 Mm Dia Door Tee 27 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75 Mm Dia Bend 28 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 10 Kgf/Cm2 29 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes,Including Jointing With Pvc Solvent Cement - 75 Mm Dia Vent Cowl 30 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia End Cap 31 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia End Cap 32 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X110 Mm Dia Door Tee 33 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 34 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/Clips At 1.00 M Spacing. This Included Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 75 Mm Dia 6Kgf/Cm2 - External Work- Exposed On Wall 35 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Partition Of Approved Brand And Manufacture, Including Top & Bottom Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Fittings, All Complete As Per Direction Of Engineer-In-Charge. 36 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge ( Door Handle, Lock And Stopper Etc To Be Paid Separately) 37 Providing And Fixing Ss H Handle Having Min 45 Cm Length In Toughed Glass Door Including All Necessary Screws Etc. Complete. 38 Providing And Fixing 3M Fasara Frosted Etching Film Of Thickness 25 Microns Self- Adhesive Of Approved Colour, Shade, And Quality With Cutting As Per Approved Design And Pattern, Including Cleaning Of Glass And Making Surface Smooth For Fixing Of Film To The Surface, All Completed As Per The Direction Of The Engineer In Charge. 39 Providing And Fixing Of Glass Door Ss Patch Lock With Out Handle In Toughened Glass Door Including All Necessary Screws Etc. Complete 40 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 41 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 42 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides 43 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) 44 Filling The Gap In Between Aluminium/ Stone/ Wood Frame And Adjacent Rcc/ Brick/ Stone/ Wood/ Ceramic/ Gypsum Work By Providing Weather/Structural Non Sag Elastomeric Pu Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete,Complying To Astm C920, Din 18540-F & Iso 11600Upto 5 Mm Depth And 5 Mm Width 45 Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 46 Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Single Rubber Stopper 47 Providing And Fixing Bright Finished 100 Mm Mortice Lock With 6 Levers Without Pair Of Handles Of Approved Quality For Aluminium Door, With Necessary Screws Etc Complete As Per Direction Of Engineer- In- Charge. 48 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 49 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised(Anodic Coating Not Less Than Grade Ac 10 As Per : 1868), Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:300X10 Mm 50 Vinyl Transparent Vision Glass Stickers: Supply And Pasting Of Vinyl Transparent Vision Glass Stickers In Approved Size And Design In Glass Partition And Door As Per The Instruction Of Engineer In Charge. 51 Backlit Acrilic Board With Projected Letters: Supply, Installation, Testing And Over Suitable Welded And Painted 25X25X3Mm Ms Angle Frame In Suitable Location And In Proper Line And Level With All Necessary Fastners, Supports Etc. Electrical Works Likes Electrical Wirings, Connections, Fittings, Externaly Fixed Weather Proof 2/3 Pin Plug Points And Sockets Including Boxes Etc. To Be Complete Properly. All Fabrication And Fixing Should Be Done As Per Approved Design And Instructions Of Engineer In Charge. (Note: Only Front Elevation Will Be Measured.) 52 Furniture 53 Supply And Erection Of Airport Type 3 Seater Waiting Chair With Powder Coated Chromium Finish Having Minimum Dimensions 1675Mm Length X 710Mm Width X 775Mm Total Height And 400Mm Seat Height . Seat: High Quality Cold Rolled 1.2Mm Thick Steel Perforated Sheet Pressed And Welded To Form The Shape. Arm & Leg: High Quality 1.2Mm Thick Ms Tube / Sheet . Cross Bar: High Quality Cold Rolled 2Mm Thick Steel Sheet Pressed And Welded To Form The Shape. 54 Supply Of Phlebotomy Chair With Optimum Design Made Up Of Ms Power Coated Frame And Up Upholstery Type Seat,Back Rest And Arm Rests.Both Side Arm Rest Should Be With Height And Position Adjustable System And All As Per The Instruction Of Engineer In Charge. 55 L-Type Workstation Of Overall Size (1350 * 600)Mm + (1000 * 450)Mm X 750 Mm (L X D X H) And Pedestal Unit Made Up Of 18 Mm Thick Exterior Grade-I Mdf Board On All Sides Conforming To Is:14587 From Approved Makes Such As Century/Greenply/Fineply Or Equivalent With Decorative Laminate On Both Side And All Edges To Be Fixed With 2Mm Thick Pvc Edge Beading. One Three-Drawer Modular Pedestal Unit Of Minimum Size 450 Mm (W) X 500 Mm (D) X 650 Mm (H) All With Retractable Key Board Tray, Drawer Channels, Hinges, Handles, Individual Locking System, And All Necessary Fittings And The Workstation Should Have An Electrical Flip Box With 2 Nos Universal Power Socket & 1 No Data Socket Etc And Cable Management Tray. All Work As Per The Approved Design And Instruction Of The Engineer-In-Charge/Architect. 56 Providing And Erection Of Reception Counter Table Of Length 1200 Mm And First Level Should Be Provided At A Height Of 750 Mm And Width 600 Mm And The Second Level At A Height Of 1050Mm From Base With A Width Of 300. The Table Made Of 18Mm Thick Pre Laminated Medium Density Board Of Exterior Grade (Grade I) Is: 14587:1998 With Decorative Laminated Finish On Both Sides And 2 Mm Thick Pvc Beading On All Edges, Including Electrical Flip Box, Cable Measurement Tray, Grommets With 3 Nos Universal Power Socket And Ethernet Port, Three Drawer Pedestal Unit With Drawer Channel, Handles, Hinges, Lock All Complete As Per Approved Drawing And Installation Of Engineer In Charge/Architect. 57 Supply And Installation Of Visitors Chair Medium Back, Mesh Back Cushion Seat With Fixed Supports Made Of 304 Stainless Steel/ Powder Coated Ms Of Approved Colour Or Shade As Per The Instruction Of The Engineer In Charge 58 Revolving Chair: Medium Back Ergonomic Chair With Five Nos. Star Shaped Nylon Base. Castor: 50Mm Diameter Nylon Twin Wheel, Gas Lift Height Adjustment, Back Angle Adjustment , Fixed Armrest Providing Natural Resting For Arms. Seat With Pu Coated Foam Backed Fabric, Back Rest With Mesh Type Fabric, Upholstery: Heavy Duty Rubber Backed Fabric In Black 59 Counter Height Stools :Supply And Erection Of Counter Height Stools ( Bar Stools ) Of Following Specifications : Revolving Adjustable Chrome Plated Steel Body Chairs With Resistance To The Corrosion. Cushion Seat With Lift Mechanism For Adjustment Of Height. Minimum Height 750Mm Before Expansion. Medium Back Rest And Arm Rest. Item Shall Be Of Reputed Make. 60 Supplying And Fixing Of Lab Work Table With 18 Mm Thick Edge Moulded Granite Top Supported Over 18Mm Thick Marine Ply Wood Of 2500Mm,L X 1200Mm,W X 850Mm, H And Powder Coated Gi Frame Of Section Size Not Less Than 50X50X1.5 Mm Including And Providing 4 Nos Under Storage Movable Cabinents Of Size 600Mm,L X 450Mm,D X 750 Mm,H And Powder Coated Steel Sheet Of Thickness Not Less Than 1Mm With 1 Drawer And Partition Bottom Storage Space With Door Including Drawer Channels, Individual Locks And Handles All As Per The Approved Drawing And Instructions Of Engineer In Charge 61 Lab Work Bench -The Work Bench Top Made Up Of 18Mm Thick Granite Top Edge Moulded Over 18 Mm Thick Marine Plywood And Gi Powder Coated Frame Work Of Section Size Not Less Than 50X50X1.5Mm. The Width Of The Table Shall Be 750Mm And Height Shall Be 850Mm. The Frame Provided With Level Adjusting Screws Fixing Accessories ,Carriage Of Material All Complete As Per The Approved Drawings And Direction Of Engineer In Charge.Note Only Length Of The Table Shall Be Measured For Making Payment. 62 Cabinet/Wardrobe: Providing And Errection Of Cabinet/Wardrobe Unit Made With 18 Mm Thick Prelaminated Mdf Board Of One Side Decorative Lamination And Other Side Balancing Lamination Having Total Unit Dimension Of 900Mm,L X 450Mm,Dx 2400Mm,H And All Edges To Be Sealed With Pvc Edge Beeding Of 2.00 Mm Thick Including All Fittings Such As Autoclose Hinges,Chromium Plated Brass Individual Locks & Handles ,Tower Bolts Etc All Required. All Shelves To Be Fix With Proper Support And Bracket Holders At A Spacing Of 400 Mm Centre To Centre And All As Per The Drawings And Instruction Of Engineer In Charge. Board Make : Greenlam/ Merino / Century/ Equivalent . Only Front Elevation Will Be Measured. 63 Overhead Storage: - Providing And Fixing Overhead Storage Unit With Minimum 18 Mm Thick Pre-Laminated Medium Density Fiber Board Exterior Grade (Grade-I) Is: 14587:1998 Marked With One Side Decorative And Other Side Balancing Lamination. Cupboard Shutters Edge To Be Sealed With Pvc Edge Bending Tape 2.00 Mm Thick Of Approved Brand Including Isi Marked Nickel Plated Bright Finishing M.S. Piano Hinges Conforming To Is:3818 Marked With Fixing Chromium Plated Brass 50 Mm Cupboard Or Wardrobe Knobs, Special Quality Chromium Plated Brass Cupboard Locks With Six Levers Of Approved Quality Including Necessary Screws Etc. Complete. Only Front Elevation Will Be Measured. 64 Electrical- Wiring 65 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 66 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 67 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 68 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 69 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 6 Sq.Mm + 1 X 6 Sq.Mm Earth Wire 70 Fixtures 71 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socketoutlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Beused In Non Residential Buildings) 72 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Ampsmodular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required 73 Supplying & Fixing Suitable Size Gl Box Wih Modular Plate And Cover In Front Onsurface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25A Modular Sp Mcb, C Curve Including Connections, Painting Etc. Asrequired. 74 Supply, Installation Of Surface Mounted Led Tubelight. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification. Luminaire Shall Be Designed To Emit At Least 3600Nominal Lumens And Efficacy Of Atleast 105 Lumen/Watt And Minimum System Wattageof 30 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Upto 30% Over 25K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. Make - Philips, Crompton, Wipro, Havells 75 Supply And Installation Of Surface/Recess Mounted Led Round/Square Luminaire With Crca Housing Suitable With Fully Diffused Diffuser For General Lighting In Offic Eareas. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K, Cool White Light. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification.Luminaire Shall Be Designed To Emit At Least 1000 Nominal Lumens And Efficacy Ofatleast 105 Lumen/Watt And Minimum System Wattage Of 10 -15 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Up To 30% Over 50K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. For Light Fittings To Be Installed In False Ceiling, All Required Cuttings Shall Be Made And Damages Shall Be Made Good As Per The Direction Of Engineer In Charge. Make-Philips, Crompton, Wipro 76 Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With Pvc Insulated And Pvc Sheathed 650/1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mm Sweep - 5 Star Rated, 3 Blade Ceiling Fan Complete With 300Mm Down Rod, Canopies,Shackles. 77 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existingmodular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 78 Supplying, Conveyance And Installation Of 3 Blade, 400 Mm Sweep, 1400 Rpm Wall Mount Fan Including Frames And All Mounting Accessories Complete. Recommended Make: Usha/ Havells/ Bajaj / Almonard Or Equivalent 79 Supplying, Conveyance And Installation Of 150 Mm Sweep,1800 Rpm Exhaust Fanincluding Frames And Allmounting Accessories Complete. Recommended Make: Usha/Havells/Bajaj Or Equivalent 80 Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc As Required. 81 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required. 82 Supply, Installation Of 12 Watt Led Bulb. 83 Db And Switchgear 84 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required6 Way (8+18) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) 85 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door 86 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 87 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 88 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 89 Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existingmcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63Amps 90 Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30Milli Amperes In The Existing Mcb Db Complete With Connections, Testing Andcommissioning Etc. As Required.63 Amps 91 Supplying And Fixing Cable End Boxes (Ip 43) Suitable For Following Single Poleand Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess,Complete With Testing And Commissioning Etc. As Required.For 6 Way, Double Door Spn Mcbdb 92 Cctv And Networking 93 Supply, Conveyance And Installing Of 2Mp Ip Dome/Bullet Camera Having 1/3Progressive Scan True Day And Night Colour Ir Camera Having Effective Pixel Of 2Mp, Video Frame Rate Of 2Mp @30Fps, Minimum Illumination Of 0.01 [email protected], 0Lux@Ir On, 20 M Ir Range, 24 Ir Led, Awb, Agc, Blc, 2D Noise Reduction,With 3.6Mm Board Lense, 12 Vdc, Poe Ip67 Rated Weatherproof Performance. 1 Year Warranty. Make: Bosch/Cp Plus/Honeywell Or Equivalent 94 Supply, Installation And Integration Of 8 Channel Embedded Linux Poe, Nvr (Network Video Recorder), Having Dual Core Embedded Processor, Must Connect 8 Channel Ip Cameras , Should Support Min 2 Sata Hdd Each Of 6Tb And Must Recordvideo Simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smartevent, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(Hevc)/H.264+/H.264, 2 Year Warranty, Image Quality Should Be Maintainedthroughout The Warranty Period. Make: Bosch/Cp Plus/Honeywell Or Equivalent 95 Supply And Installation Of Network Switch. 8 Port Poe Switch 1000Base-T Copper Ethernet Poe+ Connections, 10M/100M/1G Rj-45 Copper Ports, 1000Base-X Fiber Sfp Ports, 8 Port Auto Sensing 10/100/1000 Mbps Poe, Minimum Cpu Memory 512 Mb With 2 Sfp/Combo Ports, Energy Efficient Ethernet (Ieee 802.3Az). Make: Cisco/Cp Plus/ Netgear Or Equivalent 96 Supply And Fixing Of 6U Wall Mounting Rack With Supply And Fixing Of Mounting Brackets For Support Lockable Front Door And Detachable Side Doors, Cable Manager And Pdu Of 4 Or 6 Sockets Including Cooling Fan With Accessories Complete 97 Supply And Installation Of 8Tb Hard Disk 98 Supply And Installation Of Led Color Monitor Of Minimum 32 Inch Screen, Complete,Uhd Display Make: Lg/Samsung/Panasonic Or Equivalent. 99 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable 100 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 101 Supplying And Fixing Rj45 Outlet Including Cover Plate, Keystone Jack And Gang Box Supporting, Connection Etc. As Required 102 Air Conditioning System 103 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Followingcapacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Single Phase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 2 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 104 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Following Capacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Singlephase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4 M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 1.5 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 105 Supply And Installation Of Additional Copper Piping, Cabling From Indoor To Outdoor And Drain Piping For Air Conditioning Unit With Proper Insulation Including All Required On Wall/Above False Ceiling Complete 106 Supply, Installation, Testing And Commissioning Of True On-Line Double Conversion 6 Kva Ups System With 1:1 Crest Factor Single Phase Phase Input – Singlephase Output. Inversion Shall Be Microprocessor Controlled With Instantaneous Sine Wave Control Using Igbt. Ups Shall Have Standard Display Features, Alarms, Safeties, Etc Input Voltage Range : A) Phase & Single Phase With Ground B)Votage Range 190 Vac & 250 Vac C)Input Frequency : 50/60 Hz D)Power Factor : 0.95 Or Above E)Thd : Less Than 5% With Full Load Bypass F) Voltage Range & 200Vac & 240 Vac G) Frequency Range – 45-55 Hz/55-65 Hz Output Voltage Range H)Voltage Range & 200Vac & 240 Vac I)Frequency Range & 50/60 Hz J)Voltage Distortion & Linear Load = 2% K)Voltage Distortion – Nonlinear Load = 5% L)Output Waveform – Pure Sinewave M) Minimum Back Up Time : Continuous 60 Minutes At Full Load Rectifier Shall Be Full Wave Type (Shall Fully Meet The Specified Input Power Requirements) Battery Type: Sealed Lead Acid Maintenance Free Dc Voltage : 24/48/96V Dc System, Battery Nos And Capacity Shall Be Designed For Optimum Storage Space. Make: Liebert Vertiv/Apc By Schneider/Numeric By Legrand 107 Visi Cooler And Refrigerator 108 Supply And Installation Of 260 Litre Refrigerator, Direct-Cool Model With A Minimum 3-Star Bee Rating And Stabilizer-Free Operation. It Shall Use Eco-Friendly Refrigerant (R600A) And Have A High-Efficiency, Low-Noise Compressor. The Unit Shall Include Toughened Glass Shelves, A Vegetable Crisper, Bottle Storage For 2L Bottles, An Internal Freezer Compartment, And A Removable Anti-Bacterial Gasket. It Shall Operate On 230V, 50Hz Ac And Include Standard Accessories Such As An Ice Tray And Egg Tray. The Refrigerator Shall Have 1-Year Comprehensive Warranty And 10-Year Compressor Warranty, With Bis Certification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
4.
Defence #11315676 AOC
Tender for M&L Brick Work With Sub-Class ‘B Bricks (With Old Size Bricks), Straight Or Curved On Plan Exc. 6.0 Metre Mean Radius, Built In Cement Mortar 1:6, And Including Demolition Of Brick Work Or Stone Masonry Built In Cement Mortar Incl All Quoins Arches Pillars Etc. Complete All As Specified And As Directed. , M & L For Plain Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Aggreagte As In Coping Bed Block Etc Complete All As Specified And As Directed , M&L Plain Cement Concrete In Surface Channels,Benching In Sewers,Drains Etc Type B1 (1:2:4) Using 20 Mm Graded Stone Aggregate Complete All As Specified And As Directed. , M & L For Redndering In Cement Mortar (1:4) 15Mm Thick On Concrete /Brick Masonry Wall Surfaces, Complete All As Specified And As Directed. (Note Wpc Paid Separetely) , M&L Pre-Cast Reinforced Cement Concrete (1:2:4) (20Mm Graded Aggregate) In Cover Slab Of Manholes, Septic Tanks, Etc., Set In Cement Mortar (1:4) Including Demolition Of Existing Reinforced Cement Concrete Slabs ., Complete All As Specified And As Directed. Note : Reinforcement Will Be Measured And Paid Separately Under Appropriate Items. , M&L Tmt Bars 10Mm Dia And Overcut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping For Columns Hooking Ends And Binding With And Including Mild Steel Wire (Annealed) Not Less Than 0.90Mm Dia, Complete All As Specified And As Directed. , M&L Two Coats Of Cement Base Paint Over A Coat Of Primer On New Wall Surface Including Preparation Of Surface. Complete All As Specified And As Directed. , M&L Preparation Of Old Surface Of Wall And Applying One Coat Of Cement Base Paint Complete All As Specified And As Directed. , Dismantling Posts Or Struts (Wood, Steel Or R.C.C.) Any Section, Including Taking Out Embedded Portion & Making Good Disturbed Ground Embedded In Concrete, Brick Work, Masonry, Etc. Complete All As Specified And As Directed. , Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In & Raming Earth/ Broken Rubble Mixed With Earth Around, In Layers N. Exc. 25Cm, Watering, & Removing Surplus Soil To A Distance N Exc 50M & Making Good Surface In Soft/Loose Soil. Complete All As Specified And As Directed. , M&L Plain Cement Concrete In Foundations, Filling And Mass-Concrete Type B2 (1:2:4) Using 40 Mm Graded Stone Aggregate. Complete All As Specified And As Directed. , S&F Hand Rails, Half Round Or Other Stock Section Or Core For Wooden Hand-Rail Straight Portion, Drilled & Countersunk For Balusters Running Bars, For Doors,Balusters,Nosing To Steps Including Embeding In Concrete & Screwing Etc. Wind Ties For Roof Including Securing Bolts; Posts & Struts In Fencing Including Cutting Tops To Shape As Directed, Drilling Holes, Notching For Wire, Etc.; Flat Iron Fillets (For Securing Wire Mesh Etc.) Including All Necessary Drilling, Bolting Or Riveting, Etc., & Similar Work Conforming To Fe 290-0 Gde E-165 Complete All As Specified And As Directed. , Material And Labour For Mild Steel Round Bars 6Mm Dia And Over, Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping Columns, Hooking Ends And Binding With Welding For Securing Chain Link Fencing Etc Conforming To Fe-290.Gde-E-165, Complete All As Specified And Directed., Complete All As Specified And As Directed. , Applying Two Coats Of Synthetic Enamel Paint On Steel & Iron Surfaces Of Any Description, Not Otherwise, Described, Over 10Cm Width Or Girth Including Preparation Of New Surface & Applying One Coat Of Red Oxide, Zinc Chrome Complete All As Specified And As Directed. , M&L Preparing Surface Of Ends Of Post, Steel & Iron Work, New Or Old & Treated With Tar Or Coal Tar Black Paint, Area Tarred Exc 0.1 Sq. M. But N Exc 0.5 Sq. M Each, Treating Ends Of Posts, Backs Of Chowkats, Etc. Complete All As Specified And As Directed. , All As Per Item No 15 Above Herein Before But Not Exceeding 10Cm Wide Or Girth. Complete All As Specified And As Directed. , M&L For Mild Steel Work For Securing Of Chain Link Fencing And Similar Small Articles Etc Confirming To Is-15911 Complete All As Specified And As Directed. , S & F Ms Screw Bolts 5 To 10Mm Dia (Machine Made) With Hexagonal Or Square Head At One End, Screwed End To Be Fitted With Washer And One Hexagonal / Square Nuts And 5 To 10 Cm Long Complete All As Specified And As Directed. , S&F In Repairs For Galvanised 2 Strand Steel Barbed Wire 2.24Mm Dia Barbed With 2Mm Dia Barbs At 75Mm Spacing And Straining And Fixing To Any Type Of Standard Rails Straining Bolts Including Securing Or Tying At Cross With And Provision Of Galvanised Mild Steel Wire, Staples Or Steel Pins Etc Complete All As Specified And As Directed. (Each Line To Be Measured Separately) , Fixing Only Chain Link Fencing Including Line Wires, Any Mesh, Size And Type To Any Type Of Standards, Rails, Straining Bolts, Etc.Including Provission Of Binding Wire Complete All As Specified And As Directed. , Supply Only Chain Link Ms Galvanisd Fencing, Any Size Or Type Complete All As Specified And As Directed. , Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) And Hanging; Also Fastening And Fixing Confirming To Fe 410,E-250 Qualitry A Including Dismantling Wrought Or Mild Steel Work Of Any Description Not Otherwise Provided For Complete All As Specified And As Directed. , M& L For Granite Of Any Type 20Mm Thick Cut Beded And Jointed With Grey Cement Slurry And Pointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Grinding And Polishing Complete In Vertical Surfaces Of Wall Incl 10 Mm Thick Backing Coat In Cm (1:4) Including Demolition Of Stone Slabs Tiles Of Any Description Or Thickness In Floors Aprons Laid Bedeed And Pointed In Any Morter And Any Position. Complete All As Specified And As Directed. , Demolition Of Un- Reinforced Cement Concrete In Ground Floors And Pavings Not Exceeding 15 Cm Thickness. (Below Or Above Ground Level) Complete All As Specified And As Directed. , M&L For Plain Cement Concrete (1:3:6) Type C21 Using 40Mm Graded Aggreagte As In In Foundations, Filling, Sub Base And Mass Concrete Including Use And Waste Formwork As Ordered/Required At Site, Complete All As Specified And As Directed. , M&L For Providing And Laying 60Mm Thick Factory Made Chamfered Edge Cement Concrete Paver Block Of M-35 Grade With Approved Colour, Design & Pattern As In Footparth, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc., Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compacted Bed Of Fine Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Incl Demolition Of Old Paver Block, Complete All As Specified And As Directed. , M&L For Providing And Laying 80Mm Thick Factory Made Chamfered Edge Cement Concrete Paver Block Of M-35 Grade With Approved Colour, Design & Pattern As In Footparth, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc., Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compacted Bed Of Fine Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Incl Demolition Of Old Paver Block, Complete All As Specified And As Directed. , S&F In Repair 450Mm Bore Reinforced Concrete Pipes, Class Np2, Laid And Jointed Complete With Collars Including Dismantling Of Cast Iron Or Reinforced Concrete Drain Pipes, Jointed In Cement Mortar And Taking Out Of Trenches, Complete All As Specified And As Directed. If Required , M&L For Cement Concrete (1:3:6) Type C-2 (Using 40Mm Graded Stone Aggregate ) Concrete Bed To Drain Pipes 450Mm Bore Including Packing Under And Completely Surrounding Pipes With Concrete After They Are Laid And Tested In Complete All As Specified And As Directed. , M&L For Providing Precast Cement Concrete (1:2:4) Type B-1 (Using 20Mm Graded Stone Aggregate Set In Cement Mortar (1:4) In Kerb Stone With Plain Fair Faces Complete All Specified And As Directed , S &F Repairs Of Seccon Concertina Coil 600Mm Dia (Before Stretching) With 10-12 Stands Of Srpbt Wire Of Minimum Dia 2.59 Tensile Strength Of 1620 N/Sqmm With Anticorrosive Mint Green Paint Conforming Is -513Dd Grade & Is -4454 Part I/1981 Grade-Ii For Respective Material Of Razor Bldg And Core Wire Including All Fixing Arrangements As Per Manufactures Instruction For Fixing & Erection Complete All As Specified And As Directed. By Engineer-In-Charge
Contract Date: Jul 04, 2026 Contract Value : 77.63 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 10
5.
Defence #11315667 Technical Bid
Tender for M&L For Brick Work With Sub-Class ‘B Bricks (With Old Size Bricks), Straight Or Curved On Plan Exc. 6.0 Metre Mean Radius, Built In Cement Mortar (1:6), And Including Demolition Of Brick Work Or Stone Masonry Built In Cement Mortar Incl All Quoins Arches Pillars Etc. Complete All As Specified And As Directed. , M & L For Plain Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Aggreagte As In Coping Bed Block Etc Complete All As Specified And As Directed , M&L Plain Cement Concrete In Surface Channels,Benching In Sewers,Drains Etc Type B1 (1:2:4) Using 20 Mm Graded Stone Aggregate Complete All As Specified And As Directed. , M & L For Rendering In Cement Mortar (1:4) 15Mm Thick On Concrete /Brick Masonry Wall Surfaces, Complete All As Specified And As Directed. (Note Wpc Paid Separetely) , M&L Pre-Cast Reinforced Cement Concrete (1:2:4) (20Mm Graded Aggregate) In Cover Slab Of Manholes, Septic Tanks, Etc., Set In Cement Mortar (1:4) Including Demolition Of Existing Reinforced Cement Concrete Slabs Complete All As Specified And As Directed. (Note : Reinforcement Will Be Measured And Paid Separately Under Appropriate Items.) , M&L Tmt Bars 10Mm Dia And Overcut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping For Columns Hooking Ends And Binding With And Including Mild Steel Wire (Annealed) Not Less Than 0.90Mm Dia, Complete All As Specified And As Directed. , M&L Two Coats Of Cement Base Paint Over A Coat Of Primer On New Wall Surface Including Preparation Of Surface.Complete All As Specified And As Directed. , M&L Preparation Of Old Surface Of Wall And Applying One Coat Of Cement Base Paint Complete All As Specified And As Directed. , Dismantling Posts Or Struts (Wood, Steel Or R.C.C.) Any Section, Including Taking Out Embedded Portion & Making Good Disturbed Ground Embedded In Concrete, Brick Work, Masonry, Etc.Complete All As Specified And As Directed. , Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In & Raming Earth/ Broken Rubble Mixed With Earth Around, In Layers N. Exc. 25Cm, Watering, & Removing Surplus Soil To A Distance N Exc 50M & Making Good Surface In Soft/Loose Soil.Complete All As Specified And As Directed. , M&L Plain Cement Concrete In Foundations, Filling And Mass-Concrete Type B2 (1:2:4) Using 40 Mm Graded Stone Aggregate Complete All As Specified And As Directed. , S&F Hand Rails, Half Round Or Other Stock Section Or Core For Wooden Hand-Rail Straight Portion, Drilled & Countersunk For Balusters Running Bars, For Doors,Balusters,Nosing To Steps Including Embeding In Concrete & Screwing Etc. Wind Ties For Roof Including Securing Bolts; Posts & Struts In Fencing/ View Cutter Including Cutting Tops To Shape As Directed, Drilling Holes, Notching For Wire, Etc.; Flat Iron Fillets (For Securing Wire Mesh Etc.) Including All Necessary Drilling, Bolting Or Riveting, Etc., & Similar Work Conforming To Fe 290-0 Gde E-165 Complete All As Specified And As Directed. , Material And Labour For Mild Steel Round Bars 6Mm Dia And Over, Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping Columns, Hooking Ends And Binding With Welding For Securing Chain Link Fencing Etc Conforming To Fe-290.Gde-E-165, Complete All As Specified And Directed., Complete All As Specified And As Directed. , Applying Two Coats Of Synthetic Enamel Paint On Steel & Iron Surfaces Of Any Description, Not Otherwise, Described, Over 10Cm Width Or Girth Including Preparation Of New Surface & Applying One Coat Of Red Oxide, Zinc Chrome Complete All As Specified And As Directed. , M&L Preparing Surface Of Wood & Wood Based Materials, Steel & Iron Work, New Or Old & Treated With Tar Or Coal Tar Black Paint, Area Tarred Exc 0.1 Sq. M. But N Exc 0.5 Sq. M Each, Treating Ends Of Posts, Backs Of Chowkats, Etc.Complete All As Specified And As Directed. , All As Per Item No.Above Herein Before But Not Exceeding 10Cm Wide Or Girth. Complete All As Specified And As Directed. , M&L For Mild Steel Work For Securing Of Chain Link Fencing And Similar Small Articles Etc Confirming To Is-15911 Completed All As Specified And As Directed. , S & F Ms Screw Bolts 5 To 10Mm Dia (Machine Made) With Hexagonal Or Square Head At One End, Screwed End To Be Fitted With Washer And One Hexagonal / Square Nuts And 5 To 10 Cm Long All As Complete All As Specified And As Directed. , S&F In Repairs For Galvanised 2 Strand Steel Barbed Wire 2.24Mm Dia Barbed With 2Mm Dia Barbs At 75Mm Spacing And Straining And Fixing To Any Type Of Standard Rails Straining Bolts Including Securing Or Tying At Cross With And Provision Of Galvanised Mild Steel Wire, Staples Or Steel Pins Etc All As Complete All As Specified And As Directed. (Each Line To Be Measured Separately) , Fixing Only Chain Link Fencing Including Line Wires, Any Mesh, Size And Type To Any Type Of Standards, Rails, Straining Bolts, Etc.Including Provission Of Binding Wire Complete All As Specified And As Directed. , Supply Only Chain Link Ms Galvanisd Fencing, Any Size Or Type Complete All As Specified And As Directed. , Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) And Hanging; Also Fastening And Fixing Confirming To Fe 410,E-250 Qualitry A Including Dismantling Wrought Or Mild Steel Work Of Any Description Not Otherwise Provided For Complete All As Specified And As Directed. , M& L For Granite Of Any Type 20Mm Thick Cut Beded And Jointed With Grey Cement Slurry And Pointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Grinding And Polishing Complete In Vertical Surfaces Of Wall Incl 10 Mm Thick Backing Coat In Cm (1:4) Including Demolition Of Stone Slabs Tiles Of Any Description Or Thickness In Floors Aprons Laid Bedeed And Pointed In Any Morter And Any Position. , Demolition Of Un- Reinforced Cement Concrete In Ground Floors And Pavings Not Exceeding 15 Cm Thickness. (Below Or Above Ground Level) Complete All As Specified And As Directed. , M&L For Plain Cement Concrete (1:3:6) Type C21 Using 40Mm Graded Aggreagte As In In Foundations, Filling, Sub Base And Mass Concrete Including Use And Waste Formwork As Ordered/Required At Site, Complete All As Specified And As Directed. , M&L For Providing And Laying 60Mm Thick Factory Made Chamfered Edge Cement Concrete Paver Block Of M-35 Grade With Approved Colour, Design & Pattern As In Footparth, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc., Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compacted Bed Of Fine Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Incl Demolition Of Old Paver Block, Complete All As Specified And As Directed. , M&L For Providing And Laying 80Mm Thick Factory Made Chamfered Edge Cement Concrete Paver Block Of M-35 Grade With Approved Colour, Design & Pattern As In Footparth, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc., Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compacted Bed Of Fine Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Incl Demolition Of Old Paver Block, Complete All As Specified And As Directed. , S&F In Repair 450Mm Bore Reinforced Concrete Pipes, Class Np2, Laid And Jointed Complete With Collars Including Dismantling Of Cast Iron Or Reinforced Concrete Drain Pipes, Jointed In Cement Mortar And Taking Out Of Trenches, If Required , S&F For Cement Concrete (1:3:6) Type C-2 (Using 40 Mm Graded Stone Aggregate) Concrete Bed To Drain Pipes 450 Mm Bore Includimg Packing Under And Completely Surrounding Pipes With Concrete After They Are Laid And Tested In Complete All As Specified And As Directed . , M&L For Providing Precast Cement Concrete (1:2:4) Type B-1 (Using 20 Mm Graded Stone Aggregate Set In Cement Mortar (1:4) In Kerb Stone With Plain Fair Faces Complete All As Specified And As Directed , S&F Repairs Of Seccon Concertina Coil 600 Mm Dia (Before Stretching )With 10-12 Stands Of Srpbt Wire Of Minimum Dia 2.59 Tensile Strength Of 1620 N/Sqmm With Anticorrosive Mint Green Paint Conforming To Is-513 Dd Grade & Is-4454 Part I /1981 Garde -Ii For Respective Material Of Razor Bldg And Core Wire Including All Fixing Arrangements As Per Manufactures Instruction For Fixing & Erection Complete All As Specified And As Directed By Engineer-In-Charge , S& F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering /Cladding To Wall Fixed With Self Tapping Screw ,Including Dismantling Plain Or Corrugated Steel Sheeting Any Gauge ,Thickness In Roof Covering. Complete All As Specified And As Directed , S& F Pre Painted Galvalume Zinc Coating Gi Based Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering /Cladding To Wall Fixed With Self Tapping Screw ,Including Dismantling Plain Or Corrugated Steel Sheeting Any Gauge ,Thickness In Roof Covering. Complete All As Specified And As Directed , S&F Rolled Sections As In Main And Cross Beams, Hip And Jack Rafters; Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates To Fe-290 (Gde E -165) Complete All As Specified And As Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
6.
Educational and Research Institute #11307517 Technical Bid
Tender For Ambedkar Gramam Project For Sc Unnathy Pookkunnimala- 1 1) Anganwadi-Civil Works-Ground Floor 2 15.9.2 Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar 3 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 4 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 5 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 6 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 7 15.13.1 Taking Out Doors, Windows And Clerestory Window Shutters (Steel Or Wood ) Including Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 8 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge.All Kinds Of Soil 9 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 10 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 11 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 12 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 13 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 14 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 15 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 16 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 17 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 18 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 19 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 20 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 21 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 22 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 23 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Bepaid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 24 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 25 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 26 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 27 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 28 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 29 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 30 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 31 Od123879/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 4 Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 32 Od123885/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 33 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 34 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 35 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 36 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 37 11.16.1 Precast Terrazo Tiles 22 Mm Thick With Graded Marble Chips Of Size Upto 12Mm, Laid In Floors, And Landings, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles Including Rubbing And Polishing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) :Light Shade Pigment Using White Cement 38 8.2.2.2 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror, Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm 39 8.3.2 Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer -In-Charge.Granite Work 40 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 41 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 42 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 43 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 44 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 45 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 46 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 47 Od134882/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 48 Od134893/2025-2026 Providing And Fixing Anganwadi/Library/Vignjaanwadi -Foundation Stone/Inauguration Stone Using Granite Of Size 70.00X135.00 Cm ,18Mm Thick With Writing Letters In Golden Colour Including Of All Material And Labour Charges Etc. Complete As Per The Directions Of Engineer-In-Charge. 49 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 50 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 51 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 52 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 53 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 54 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm) 55 Od141946/2025-2026 Providing And Fixing 8 Upvc Aqua Pathy ( Gutter) With M.S Clamp All Complete As Per Direction Of Engineer-In-Charge. 56 1)Vignjaanwadi,Library Cum Reading Room-First Floor 57 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 58 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 59 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 60 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 61 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 62 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 63 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 64 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 65 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 66 13.4.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Coarse Sand) 67 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 68 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 9 Paid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 69 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 70 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 71 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 72 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 73 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 74 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 75 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 76 Od127305/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm 28-30Mm Thickness With Frame And Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 77 Od126510/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 78 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 79 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 80 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 81 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 82 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 83 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 84 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 85 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 86 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 87 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 88 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 89 Od135395/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 90 1)Plumbing Works -Ground Floor & First Floor 91 17.3.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 92 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 93 17.7.2 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 94 17.9.1 Providing And Fixing Kitchen Sink With C. I Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm 95 18.53.1 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 96 18.32.1 Constructing Masonry Chamber 30X30X50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Stop Cock, With C.I. Surface Box 100X100X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With Common Burnt Clay F.P.S (Non Modular) Bricks Of Class Designation 7.5 97 17.73.2 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighting Not Less Than 190 Gms 98 18.51.1 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15 Mm Nominal Bore 99 50.18.7.2.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Claps At 1.00 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 20 Mm Dia 12Kgf/Cm2 - Internal Work - Exposed On Wall 100 50.18.9.3.2 Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 25 Mm Dia 10Kgf/Cm2 101 50.18.7.6.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 10 Kfg/Cm - Internal Work- Exposed On Wall 102 50.18.9.7.1 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf/Cm3 103 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 104 50.18.9.22.1 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 105 50.18.9.22.2 Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 106 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 107 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110X110 Mm Dia Tee 108 50.18.9.22.7 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X75 Mm Dia Door Tee 109 18.58.2.1 Providing And Fixing Ptmt Grating Of Approved Quality And Colour. Rectangular Type With Openable Circular Lid150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 110 51.19.St4 Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately) 4. 35 To 50 Flush Capacity 111 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 112 Od141980/2025-2026 Providing 25Mm/32Mm (3/4 Inch/1 Inch) Public Building Connection With 20Mm (3/4 Inch) Water Meter From Existing Ci Mains Up To 125 Mm Dia., Up To A Length Of 5 M Using 25Mm Indian Standard Class 6 Upvc Pipe And Upvc / Gm / Brass Specials Viz. Brass Ferrule, Gm Full Way Wheel Valve, Elbow, Mta, Fta, Couplers Etc. And Connecting With The Mains, Testing The Joints Etc. Complete Including Trenching And Refilling In All Kinds Of Soil Up To A Depth Of 1.50M For Main Line Tracing And Trench Of Average Cross Section 0.3M X 0.75M For Laying Connection Pipe And Service Pipe, Fixing Water Meter, Lighting, Watching, Providing Caution Boards, Traffic Control Etc. Complete Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges , Cost Of Water Meter And Meter Box, Deposit Charges Of Kwa And Including Charges For Cutting The Concrete / Tarred / Bituminous Roads Etc, If Necessary And As Per The Direction Of The Engineer-In-Charge. 113 1)Electrical Works -Ground Floor & First Floor 114 1.10.3 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 115 1.14.2 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 116 1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 Amp Socket Outlet 117 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch 118 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet 119 1.12 Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 120 2.3.3 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way, Double Door 121 1.25 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 122 5.4 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. 123 5.19 Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. 124 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75Mm) 125 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps 126 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 127 1.14.1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 128 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 129 Od123876/2025-2026 Supplying And Fixing Following 32 Amps Modular Dp Switch And Other Accessories Etc Complete 130 Od123878/2025-2026 Supplying And Fixing 14 W Led Connect With Bulk Head Fixing And Other Accessories 131 Od123874/2025-2026 Supply And Fixing Angle Batten With 7/9 Watts Led And Other Accessories 132 Od123877/2025-2026 Supply And Fixing Angle Batten With 14/15 Watts Led And Other Accessories 133 Od123872/2025-2026 Supplying And Fixing 20W Led Tube Set (Approved Brands) And Other Accessories 134 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply 135 Od123875/2025-2026 Supplying, Installing, Testing And Commissioning Of Wall Mounted Single Phase 2 Wire Energy Meter With Meter Box Poly Carbonate Body Having Range Of 32 Amp With Enclosure Made Out Of Powder Coated 16 Swg Sheet Suitable For Fixing In Surface/ Recess With Fuse Unit 32 Amp With Neutral Link, Its Interconnection Etc. The Enclosure Shall Have Lockable Door With Glass Window And All Mounting Accessories Etc. Complete As Required Including Kseb Charges 136 2)Childrens Play Equipments 137 Od135736/2025-2026 Supply And Fixing ChildrenS Play Equipment Circular See-Saw Including Cost Of All Materials And Labour Charges Etc Complete. 138 Od135738/2025-2026 Supplying And Fixing ChildrenS Play Equipment Step With Slide Including Cost Of All Materials And Labour Charges, Etc. 139 3)Community Hall-Renovation-Civil Works 140 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 141 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 142 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 143 13.33.1 Pointing On Stone Work With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand):Flush/ Ruled Pointing 144 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 145 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 146 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 147 13.91 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete 148 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 149 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 150 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 151 13.88 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 152 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 153 13.99.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 154 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 155 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 156 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 20 Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 157 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
7.
Housing Urban and Rular Development #11306856 AOC
Tender For M.O.W. Work (Additional Room) In Bunglow No. Eg-9/3 And Ek-9/3 Under Section No.1 Survey Sub Dn. Bhopal- 1 M.O.W. Work (Additional Room) in Bunglow No. EG-9/3 and EK-9/3 Under Section No.1 Survey Sub Dn. Bhopal 1st Call P.A.C. 29.64 Lakh,as per Building SOR wef 01-01-2024 Schedule Attached Complition period 90 Days Please Enable Macros to View BoQ information SCHEDULE OF ITEMS Name of work : M.O.W. Work (Additional Room) in Bunglow No. EG-9/3 and EK-9/3 Under Section No.1 Survey Sub Dn. Bhopal Probable Amount of contract : Rs. 29.64 Lacs. (Rs. in Figures) : Time Alloved : 6 months i/c rainy season S.No SOR Item Particulers of Item Unit Rate Remarks 2 2.4 2.4.1 beyond 30 cm girth up to and including 60 cm girth each 350.0 2.4.2 beyond 60 cm girth up to and including 120 cm girth each 1150.0 2.4.3 beyond 120 cm girth up to and including 240 cm girth each 3500.0 2.4.4 above 240 cm girth each 6300.0 3 2.7 2.7.1 Ordinary rock cum 287.0 2.7.2 Hard rock (requiring blasting) cum 519.0 2.7.3 Hard rock (blasting prohibited) cum 828.0 4 2.25 2.25.1 All kinds of soil. cum 30.0 2.25.2 Ordinary or hard rock. cum 53.0 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete cum 672.0 Note: - Maximum thickness of this layer shall be 20 cm. 5 2.27 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) cum 393.0 2.27.2 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm cum 331.0 6 2.28 2.28.1 All kinds of soil. each 42.0 2.28.2 Ordinary rock each 68.0 2.28.3 Hard rock (requiring blasting) each 138.0 2.28.4 Hard rock (blasting prohibited) each 151.0 7 2.3 2.30.1 Along external wall where the apron is not provided using chemical emulsion@ 7.5 liters / sqm of the vertical surfaceof the substructure to a depth of 300mm including excavation channel along the wall and rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 36.0 2.30.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 42.0 2.30.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. sqm 199.0 2.30.4 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling 10mm dia and 200mm deep holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 50.0 2.30.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litresper hole by drilling 6 mm dia holes at downward angle of 45 degree at 150mm centre to centre and sealing the same. metre 201.0 8 2.41 2.42.1 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. cum 331.0 9 4.1 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-25 – Grade concrete cum 6338.0 4.1.1.2 M-20 – Grade concrete cum 4933.0 4.1.1.3 M-15 – Grade concrete cum 4471.0 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) cum 3890.0 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete cum 4403.0 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) cum 3808.0 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate cum 3474.0 4.1.3 With fly ash. Note: No fly ash is to be added to Portland Pozzolona cement in any case which itself contains fly ash. 10 4.2 string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1 With 20mm nominal size graded stone aggregate 4.2.1.1 M-25 – Grade concrete Cum 6582.0 4.2.1.2 M 20 – Grade concrete Cum 5177.0 4.2.1.3 M 15 – Grade concrete Cum 4714.0 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate Cum 4134.0 4.2.2 With 40mm nominal size graded stone aggregate 4.2.2.1 M-15 - Grade concrete cum 4647.0 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate cum 4052.0 11 4.3 4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. Sqm 169.0 4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. sqm 267.0 4.3.3 Above plinth: Columns, pillars, posts and struts. Sqm 356.0 12 4.6 4.6.1 M-25 (With 20mm nominal size graded stone aggregate) cum 5095.0 4.6.2 M-20 (With 20mm nominal size graded stone aggregate) cum 5558.0 4.6.3 M-15 (With 20mm nominal size graded stone aggregate) cum 5095.0 4.6.4 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. cum 4515.0 4.1 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size). Sqm 200.0 13 5.1 5.1.1 M-20 Grade Concrete cum 6153.0 5.1.2 M-15 Grade Concrete cum 5397.0 14 5.2 5.2.1 M-20 Grade Concrete cum 6231.0 15 5.3 5.3.1 M-20 Grade Concrete cum 6541.0 16 5.4 5.4.1 M-20 Grade Concrete cum 5542.0 17 5.5 5.5.1 M-20 Grade Concrete cum 6906.0 18 5.6.1 5.6.1 M-20 Grade Concrete cum 6337.0 19 5.7.1 5.7.1 M-20 Grade Concrete cum 5448.0 20 5.9.1 5.9.1 Foundations, footings, bases of columns, etc. for concrete upto plinth level sqm 190.6 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 Uptoplinthlevel. sqm 219.0 5.9.2.2 Above plinth upto 3.6 m height from plinth level sqm 330.0 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. sqm 40.0 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 439.6 5.9.4 Shelves(Cast in situ) sqm 290.0 5.9.5 Lintels, beams, girders, bressumers and cantilevers sqm 356.0 5.9.6 Columns, P i l l a r s , Piers, Abutments, sqm 471.2 Posts and Struts. 5.9.7 Stairs, (excluding landings) except spiral- Staircases. sqm 435.7 5.9.8 Spiral staircases (including landing). sqm 450.0 5.9.9 Arches, domes,vaults upto 6m span sqm 1141.6 5.9.10 Extra for arches, domes, vaults exceeding 6 m span sqm 451.3 5.9.11 Chimneys and shafts sqm 294.0 5.9.12 Coffer/waffle slab of any size or shape as shown in the drawing. sqm 1481.0 5.9.15 Extra for shuttering in circular work or any other geometrical shape (20% of respective centering and shuttering items). sqm 0.2 5.9.16 Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. sqm 191.0 5.9.17 Cornices and mouldings sqm 565.0 5.9.18 Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. sqm 529.6 5.9.19 Weather shade, Chajjas, corbels etc., including Edges. sqm 534.2 5.9.20 Suspended floors, roofs, landings, balconies and Access platform. With water proof ply 12 mm thick. (item to be executed with prior permission of C.E./S.E. in case of B & R works . sqm 575.35 5.9.21 Lintels, beams, columns, girders, bressumers and cantilevers with waterproof ply 12 mm thick (item to be executed with prior permission of C.E./S.E. in case of B & R works . sqm 521.2 21 5.1 5.10.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). sqm 212.0 22 5.12 5.12.1 50 mm thick sqm 790.0 5.12.2 40 mm thick sqm 689.0 5.12.3 25 mm thick sqm 598.0 23 5.16 5.16.1 Mild steel and Medium Tensile steel bars. kg 78 .00 5.16.2 Hard drawn steel wire kg 75.0 5.16.3 Cold twisted bars (CTD) kg 81.0 5.16.4 Hot rolled deformed bars kg 81.0 5.16.5 Hard drawn steel wire fabric kg 76.0 5.16.6 Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 kg 80.0 5.16.7 Thermo-Mechanically Treated bars. FE 500 conforming .to IS 1786 kg 77.0 5.16.8 Corrosion resistance Steel bar Grade Fe-500 D & above , use with prior permission of C.E. Kg 98.0 24 5.22 5. 22.1 12 mm thick sqm 402.0 5. 22.2 25 mm thick sqm 574.0 5. 22.3 50 mm thick sqm 674.0 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design. 5. 23.1 Non-asbestos fibre cement board 6 mm thick as per IS: 14862. 5. 23.1.1 150mm wide. RM 102.0 5. 23.1.2 200mm wide. RM 137.0 5. 23.1.3 250mm wide. RM 153.0 5. 23.2 Aluminium fluted strips 3.15mm thick. 5. 23.2.1 150 mm wide. RM 483.0 5. 23.2.2 200 mm wide. RM 646.0 5. 23.2.3 250 mm wide. RM 725.0 5. 23.3 Stainless steel Grade 304 plate-1.0 mm thick 5. 23.3.1 150 mm wide. RM 367.0 5. 23.3.2 200 mm wide. RM 443.0 5. 23.3.3 250 mm wide. RM 555.0 25 5.24 5.24.1 Preparation of grooves RM 18.5 5.24.2 Preparation of Drip course RM 30.0 26 5.32 5.32.1 Non pigmented wet curing compound sqm 93.0 5.32.2 Pigmented wet curing compound. sqm 100.0 27 6.1 6.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5818.0 6.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5626.0 28 6.2 6.2.1 Cement mortar 1:4 (1 cement : 4 sand) cum 6012.0 6.2.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5821.0 6.3 Brick work with well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process, crushing strength not lessthan 40kg /cm2 and water absorptionnot more than 15% in foundation and plinth i/c curing etc. complete. 6.3.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5252.0 6.3.2 Cement Mortar 1:6 (1 cement:6 sand). cum 5061.0 29 6.4 6.4.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5446.0 6.4.2 Cement Mortar 1:6 (1 cement:6 sand). cum 5255.0 30 6.5 6.5.1 Cement mortar 1:4 (1 cement : 4 sand) cum 4347.0 6.5.2 Cement Mortar 1:6 (1 cement: 6 sand). cum 4155.0 31 6.6 6.6.1 Cement mortar 1:4 (1 cement : 4 sand) cum 4541.0 6.6.2 Cement Mortar 1:6 (1 cement : 6 sand) cum 4350.0 32 6.7 6.7.1 Having 100 kg / cm2 average compressive strength. 6.7.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5384.0 6.7.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5162.0 6.7.2 Having 75 kg / cm2 average compressive strength. 6.7.2.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5271.0 6.7.2.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5049.0 6.7.3 Having 50 kg / cm2 average compressive strength. 6.7.3.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5158.0 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4936.0 33 6.8 6.8.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5287.0 6.8.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5095.0 34 6.9 Cement Mortar 1:4 ( 1 cement : 4 sand) 35 6.12 6.12.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 697.0 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 673.0 36 6.13 6.13.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 639.0 6.13.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 615.0 37 6.14 6.14.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 546.0 6.14.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 522.0 38 6.15 6.15.1 Having 100 kg/cm2 average compressive strength. 6.15.1.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 570.0 6.15.1.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 551.0 6.15.2 Having 75 kg/cm2 average compressive strength. 6.15.2.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 524.0 6.15.2.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 505.0 6.15.3 Having 50 kg/cm2 average compressive strength. 6.15.3.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 479.0 6.15.3.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 459.0 39 6.37 6.37.1 Having100 kg / cm2 average compressive strength. 6.37.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5115.0 6.37.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4904.0 6.37.2 Having75 kg / cm2 average compressive strength. 6.37.2.1 Cement mortar 1:4 (1 cement : 4sand) cum 5007.0 6.37.2.2 Cement mortar 1:6 (1 cement : 6sand) cum 4797.0 6.37.3 Having50 kg / cm2 averagecompressive strength. 6.37.3.1 Cement mortar 1:4 (1 cement : 4sand) cum 4900.0 6.37.3.2 Cement mortar 1:6 (1 cement : 6sand) cum 4689.0 40 9.3 9.3.1 Sal wood cum 76229.0 9.3.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. cum 77538.0 9.3.3 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 64833.0 41 9.4 9.4.1 Second class teak wood cum 9062.0 9.4.2 Sal wood cum 7131.0 9.4.3 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. cum 7275.0 9.4.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 6030.0 9.5.4.1 35 mm thick sqm 1089.0 9.5.4.2 30 mm thick sqm 969.0 42 9.6 9.6.1 Second class teak wood sqm 2215.0 9.6.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood sqm 1763.0 9.6.3 15mm thick Factory made Kiln seasoned, chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood. sqm 971.0 9.6.4 Ply wood 5 ply, 9 mm thick : 9.6.4.1 Decorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type. sqm 1439.0 9.6.4.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type sqm 1369.0 9.6.5 Ply wood 7 ply, 9 mm thick : 9.6.5.1 Decorative plywood both side decorative veneer (Type- I) conforming to IS 1328 BWR type. sqm 1861.0 9.6.5.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-1) conforming to IS 1328 BWR Type sqm 1650.0 9.6.6 Particle Board 12 mm thick 9.6.6.1 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. sqm 791.0 9.6.6.2 Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. sqm 1087.0 9.6.6.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked. sqm 1333.0 9.6.6.4 Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS: 12823 marked. sqm 1390.0 9.6.6.5 Coir Veneer Board (conforming to IS 14842) 12 mm thick sqm 1298.0 9.6.7 Float glass panes 9.6.7.1 4 mm thick glass pane (weight not less than 10 kg/sqm) sqm 973.0 9.6.7.2 5 mm thick glass pane (weight not less than 12.5 kg/sqm) sqm 1046.0 9.6.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading sqm 1532.0 9.6.8.1 4mm to 5mm thick integral PVC form sheet with Celluka finish surface on both side with density not less than 600 kg/cum sqm 580.0 9.6.8.2 4mm to 5mm thick laminated PVC form sheet with density not less than 600 kg/cum, laminated on both sides by 0.12 mm thick laminated sheet with density not less than 1400 kg/cum sqm 754.0 43 9.14 9.14.1 Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. Sqm 170.0 9.14.2 ISI marked M.S. pressed butt hinges bright finished of required size For 2nd class teak wood and other class of wood shutters. Sqm 53.0 44 9.15 9.15.1 Panelled or panelled and glazed shutters : 9.15.1.1 Using ISI marked anodised aluminium butt hinges with necessary screws. Sqm 2736.0 9.15.1.2 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 2753.0 9.15.2 Glazed shutters : 9.15.2.1 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. Sqm 2815.0 9.15.2.2 2nd class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 2759.0 45 9.16 9.16.1 12 mm thick Sqm 555.0 9.16.2 18 mm thick Sqm 654.0 46 9.17 9.17.1 18 mm thick Sqm 1270.0 9.17.2 25 mm thick Sqm 1383.0 47 9.18 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 2823.0 9.18.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 2648.0 9.18.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws. Sqm 2465.0 48 9.19 9.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 1870.0 9.19.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 1696.0 9.19.3 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 1623.0 49 9.2 9.21 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). Sqm 401.0 9.22 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : 9.22.1 Rectangular or square. Sqm 157.0 9.22.2 Circular. Sqm 244.0 50 9.25 9.25.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.1.1 Second class teak wood. Sqm 3174.0 9.25.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2599.0 9.25.1.3 Kiln seasoned selected class of sheesham wood. Sqm 2452.0 9.25.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.2.1 Second class teak wood. Sqm 3291.0 9.25.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2716.0 9.25.2.3 Kiln seasoned selected class of sheesham wood. Sqm 2569.0 9.25.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.3.1 Second class teak wood. Sqm 2797.0 9.25.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2306.0 9.25.3.3 Kiln seasoned selected class of sheesham wood. Sqm 2179.0 9.25.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.4.1 Second class teak wood. Sqm 2914.0 9.25.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2423.0 9.25.4.3 Kiln seasoned selected class of sheesham wood. Sqm 2296.0 9.26.2 30 mm thick shutters Sqm 2102.0 51 9.57 9.57.1 300x16 mm Each 170.0 9.57.2 250x16 mm Each 157.0 52 9.58 9.58.1 250x10 mm Each 68.0 9.58.2 200x10 mm Each 60.0 9.58.3 150x10 mm Each 42.0 9.58.4 100x10 mm Each 35.0 53 9.6 9.60.1 300x20x6 mm Each 72.0 9.60.2 250x20x6 mm Each 67.0 54 9.61 9.61.1 125 mm Each 27.0 9.61.2 100 mm Each 25.0 9.61.3 75 mm Each 24.0 55 9.62 9.62.1 150 mm Each 23.0 9.62.2 115 mm Each 20.0 9.62.3 90 mm Each 17.0 56 9.63 9.63.1 300 mm weighing not less than 200 gms. Each 40.0 9.63.2 250 mm weighing not less than 150 gms. Each 34.0 9.63.3 200 mm weighing not less than 120 gms. Each 28.0 57 9.65 9.65.1 300x16 mm Each 389.0 9.65.2 250x16 mm Each 326.0 9.65.3 400x16mm Each 601.0 58 9.66 9.66.1 250x10 mm Each 148.0 9.66.2 200x10 mm Each 93.0 9.66.3 150x10 mm Each 71.0 9.66.4 100x10 mm Each 50.0 59 9.68 9.68.1 300x20x6 mm Each 211.0 9.68.2 250x20x6 mm Each 173.0 9.69 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : Each 9.69.1 125 mm Each 60.0 9.69.2 100 mm Each 54.0 9.69.3 75 mm Each 48.0 60 9.7 9.70.1 150 mm each 37.0 9.70.2 115 mm each 33.0 9.70.3 90 mm each 26.0 61 9.73 9.73.1 125x64x1.90 mm each 67.0 9.73.2 100X58X1.90 mm each 59.0 9.73.3 75x47x1.80 mm each 39.0 9.73.4 50x37x1.50 mm each 25.0 62 9.74 9.74.1 125x64x2.50 mm each 76.0 9.74.2 100x60x2.50 mm each 60.0 9.74.3 75x50x2.50 mm each 46.0 63 9.76 9.77 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 9.77.1 125x85x5.5 mm (heavy type) each 456.0 9.77.2 125x70x4 mm (ordinary type) each 148.0 9.77.3 100x85x5.5 mm (heavy type) each 387.0 9.77.4 100x70x4 mm (ordinary type) each 117.0 9.77.5 75x65x4 mm (heavy type) each 145.0 9.77.6 75x40x2.5 mm (ordinary type) each 74.0 9.77.7 50x40x2.5 mm (ordinary type) each 32.0 64 9.78 9.78.1 150x125x27x5 mm each 385.0 9.78.2 125x125x27x5 mm each 345.0 9.78.3 100x125x27x5 mm each 304.0 9.78.4 75x100x20x3.2 mm each 239.0 65 9.79 9.79.1 400x10 mm each 400.0 9.79.2 250x10 mm each 329.0 9.79.3 200x10 mm each 261.0 9.79.4 150x10 mm each 221.0 9.79.5 100x10 mm each 142.0 66 9.8 9.80.1 300x16x5 mm each 237.0 9.80.2 250x16x5 mm each 225.0 67 9.81 9.81.1 125 mm each 205.0 9.81.2 100 mm each 181.0 9.81.3 75 mm each 141.0 68 9.82 9.82.1 300x16mm each 407.0 9.82.2 250x16mm each 374.0 69 9.87 9.87.1 40 mm each 144.0 9.87.2 50 mm each 150.0 9.87.3 65 mm each 162.0 9.87.4 75 mm each 185.0 70 9.99 9.99.1 Size 40 mm each 144.0 9.99.2 Size 50 mm each 156.0 9.99.3 Size 65 mm each 167.0 9.99.4 Size 75 mm each 196.0 71 9.101 9.101.1 300x16mm each 268.0 9.101.2 250x16mm each 245.0 72 9.102 9.102.1 400X10mm each 260.0 9.102.2 300x10mm each 198.0 9.102.3 250x10mm each 164.0 9.102.4 200x10 mm each 113.0 9.102.5 150x10 mm each 91.0 9.102.6 100x10 mm each 73.0 73 9.103 9.103.1 300x16x5mm each 255.0 9.103.2 250x16x5mm each 243.0 74 9.108 9.108.1 125x75x4 mm each 115.0 9.108.2 125x63x4 mm each 108.0 9.108.3 100x75x4 mm each 95.0 9.108.4 100x63x4 mm each 93.0 9.108.5 100x63x3.2 mm each 90.0 9.108.6 75x63x4 mm each 77.0 9.108.7 75x63x3.2 mm each 75.0 9.108.8 75x45x3.2 mm each 67.0 75 9.109 9.109.1 300x16 mm each 241.0 9.109.2 250x16 mm each 195.0 76 9.11 9.110.1 400X10mm each 123.0 9.110.2 300x10 mm each 114.0 9.110.3 250x10 mm each 102.0 9.110.4 200x10 mm each 82.0 9.110.5 150x10 mm each 69.0 9.110.6 100x10 mm each 55.0 77 9.111 78 9.113 9.113.1 125 mm each 75.0 9.113.2 100 mm each 55.0 9.113.3 75 mm each 46.0 79 9.114 9.114.1 Single rubber stopper each 35.0 9.114.2 Twin rubber stopper each 86.0 80 9.116 81 9.117 82 9.126 83 9.127 84 9.128 85 9.129 9.129.1 Triple strip vertical type. each 28.0 9.129.2 Double strip (horizontal type). each 23.0 9.131 Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in-charge. 9.131.1 300mm long each set 209.0 9.131.2 450mm long each set 256.0 9.131.3 500mm long each set 302.0 86 9.132 87 9.133 9.133.1 Marine plywood conforming to IS: 710 sqm 1591.0 9.133.2 Fire retardant plywood conforming to IS: 5509. sqm 1660.0 88 9.134.1 9.134.1 1.5 mm thick. sqm 851.0 89 9.134.2 90 9.138 9.138.1 12 mm thick. sqm 919.0 9.138.2 18 mm thick. sqm 1161.0 9.138.3 25 mm thick. sqm 1230.0 91 9.139 92 9.14 9.140.1 18 mm thick sqm 1493.0 9.140.2 25 mm thick sqm 2017.0 93 9.145 9.145.1 Board 12 mm thick sqm 811.0 9.145.2 Board 18 mm thick sqm 943.0 9.146 Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). 9.146.1 18 mm thick sqm 1055.0 9.146.2 25 mm thick sqm 1420.0 94 9.147 95 9.148 96 9.15 9.150.1 12 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 1210.0 9.150.2 18 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 1320.0 97 9.158 9.158.1 Extruded section Profile size 48x40 mm. metre 203.0 9.158.2 Extruded section Profile size 42x50 mm. metre 208.0 98 9.165 99 9.166 9.166.1 Plain PVC door shutters. sqm 2026.0 9.166.2 Pre laminated PVC door shutters. sqm 2490.0 100 9.167 101 9.168 as panel. The styles andrails will be mitred cut and joint with the help of PVC solvent cement and self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mmand 15 mm integrally extruded in the middle of the lock rail and fixed with styles with the help of PVC solvent cement and self driven self tapping screws of size 100 mmx8 mm complete as per manufacturers specifications and direction of Engineer-in-charge: 9.168.1 Non decorative finish. sqm 2026.0 9.168.2 Decorative finish (both side wood grained finish). sqm 2432.0 102 9.169 9.169.1 Single rebate (75 mm X 50 mm) RM 459.0 9.169.2 Single rebate (100 mm X50 mm) RM 720.0 9.169.3 Single or double rebate (125 mm X 65 mm) RM 923.0 103 9.17 9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 2250.0 9.170.2 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 3250.0 9.170.3 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 3693.0 9.170.4 35 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 4135.0 104 9.186 105 9.187 9.187.1 Casement Window (Outward/Inward opening) with hinge System. 9.187.1.1 Frame (50 mm x 50mm) metre 422.0 9.187.1.2 Sash (Style and Rail) (62 mm x 34 mm) metre 403.0 9.187.1.3 Mullion (intermediate Section) (66mm x 50 mm) metre 434.0 9.187.1.4 ‘T Profile (one vertical length in between two shutters) (24mm x 34.5mm) metre 99.0 9.187.1.5 Glazing bead (12mm x 18mm) metre 130.0 9.187.2 Casement Window (With friction hinge and outward opening) 9.187.2.1 Casement Frame (67mm x 62mm) metre 495.0 9.187.2.2 Casement Window Sash/Mullion (67mm x75mm) (style, rail and intermediate section) metre 519.0 9.187.2.3 Casement Glazing bead (35mm x 18 mm) metre 178.0 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67mm x 52mm) metre 9.187.3.2 Sliding window Sash (60mm x 44mm) metre 529.0 9.187.3.3 Sliding Interlock for Window (one vertical length in each shutter)(45.5 mm x 28 mm) metre 139.0 9.187.3.4 Sliding Glazing bead (35 mm x 18 mm) metre 178.0 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67mm x 52mm) metre 539.0 9.187.4.2 Sliding Door Sash (80mm x 44mm) metre 653.0 9.187.4.3 Sliding Interlock for Door (one vertical length in each shutter) (45.5 mm x 28 mm) metre 139.0 9.187.4.4 Sliding Glazing bead (35 mm x 18 mm) metre 178.0 106 9.188 9.188.1 200 x 19 x 1.9 mm each 321.0 9.188.2 250 x 19 x 1.9 mm each 369.0 9.188.3 300 x 19 x 1.9 mm each 462.0 9.188.4 350 x 19 x 1.9 mm each 526.0 9.188.5 400 x 19 x 1.9 mm each 636.0 107 9.189 108 9.191 109 9.192 110 9.193 111 9.194 9.194.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) sqm 6798.0 9.194.2 Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). sqm 6221.0 9.194.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). sqm 4842.0 9.194.4 Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) sqm 6681.0 9.194.5 Casement window duble panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm.) sqm 6942.0 9.194.6 Casement cum fixed panel window having both and single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm & mullion67 x 80 all having wall thickness of 2.3 ±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm. Upto 5.00 sqm.) sqm 5290.0 9.195 Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (ifrequired) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). 9.195.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) sqm 4860.0 9.196 Providing and fixing made UPVC white colour casement/ casement cum fixed glazed door comprising of UPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made fromroll forming process of required length(shape & size according to UPVC profile),UPVC 9.196.1 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). sqm 7085.0 9.196.2 Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±.0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm). sqm 7063.0 9.197 Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profileof frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) 9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) sqm 5060.0 9.197.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). sqm 6880.0 9.197.3 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm). sqm 5134.0 9.197.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area ofwindow above 1.75 sqm). sqm 6371.0 9.197.5 Three track three panels sliding window made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) sqm 5913.0 112 9.198 9.198.1 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto sqm 4332.0 4.00 sqm). 9.198.2 Two track four panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). sqm 3532.0 9.199 Providing and fixing factory made UPVC white colour sliding glazed door comprising of UPVC multi-chambered frame with in- built roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension UPVC extruded glazing beads, UPVC extruded interlock and UPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), 9.199.1 Two track two panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm upto 10.00 sqm). sqm 3676.0 9.199.2 Two track four panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 8.00 sqm upto10.00 sqm). sqm 3810.0 9.199.3 Three track three panels sliding door made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) sqm 4361.0 9.199.4 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm upto 5.00 sqm) sqm 5617.0 9.2 Providing and fixing 30mm thick factory made solid panel prelaminated PVC internal door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for styles top, lock and bottom rails. M.S.frame shall have a coat of steel primers of approved make and manufacture.M.S. frame sqm 3908.0 113 9.201 9.201.1 24 to 25 mm thick plain solid PVC flush door shutter sqm 2250.0 9.201.2 28 to 30 mm thick plain solid PVC flush door shutter sqm 3229.0 114 9.202 9.202.1 1mm thick laminated sheet sqm 3693.0 9.202.2 0.12 mm thick laminated sheet sqm 3461.0 115 9.255 9.255.1 9 mm thick BWP grade commercial Sqm 841.0 plywood 9.255.2 12 mm thick BWP grade commercial Sqm 1064.0 plywood 9.255.3 18 mm thick BWP grade commercial Sqm 1169.0 plywood 9.255.4 25 mm thick BWP grade commercial Sqm 1366.0 plywood 116 9.256 9.256.1 25 mm outer dia & 300 mm long Each Set 984.0 9.256.2 32 mm outer dia & 450 mm long Each Set 1716.0 9.256.3 32 mm outer dia & 600 mm long Each Set 2041.0 117 9.257 9.196, 9.197, 9.198, 9.199) 118 9.258 9.258.1 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. sqm 1040.0 119 10.7 10.7.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area. sqm 747.0 10.7.2 Exceeding 16.80 sqm in area. sqm 782.0 120 10.11 10.11.1 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). kg 77.0 121 10.12 10.12.1 Profile B of 1.60mm thick single rebate of size 80mmx50mm 10.12.1.1 Fixing with adjustable lugs with split end tail to each jamb. meter 402.0 10.12.1.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 394.0 10.12.2 Profile C of 1.60mm thick single rebate of size 100mmx50mm 10.12.2.1 Fixing with adjustable lugs with split end tail to each jamb. meter 431.0 10.12.2.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 424.0 10.12.3 Profile E of 1.60mm thick double rebate of size 115mmx50mm 10.12.3.1 Fixing with adjustable lugs with split end tail to each jamb. meter 472.0 10.12.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 464.0 10.12.4 Profile B of 1.25mm thick single rebate of size 80mmx50mm 10.12.4.1 Fixing with adjustable lugs with split end tail to each jamb. meter 356.0 10.12.4.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 348.0 10.12.5 Profile C of 1.25mm thick single rebate of size 100mmx50mm 10.12.5.1 Fixing with adjustable lugs with split end tail to each jamb. meter 385.0 10.12.5.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 377.0 10.12.6 Profile E of 1.25mm thick double rebate of size 115mmx50mm 10.12.6.1 Fixing with adjustable lugs with split end tail to each jamb. meter 414.0 10.12.6.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 406.0 122 10.14 10.14.1 Hot finished welded type tubes kg 117.0 10.14.2 Hot finished seamless type tubes kg 123.0 10.14.3 Electric resistance or induction butt welded tubes. kg 142.0 10.15 Design, supply, fabrication, taransportion and erection of structural steel/mild steel built-up sections for steel building in column, rafter, truss, floor joist, wind bracings, tie beam, foundation bolts, fasteners etc. Including two coats ofEpoxy paint and one coat of primer. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code. kg 132.0 123 10.17 124 10.18 125 10.19 126 10.21 127 10.22 10.22.1 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. kg 101.0 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. kg 105.0 128 10.23 10.23.1 M.S. tube. kg 117.0 10.23.2 E.R.W. tubes. kg 132.0 129 10.25 130 10.26 10.26.1 Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4 mm aperture on both sides sqm 646.0 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. sqm 1334.0 131 10.27 10.27.1 With 4.0 mm thick glass panes sqm 792.0 10.27.2 With 5.50 mm thick glass panes sqm 873.0 10.27.3 With 1mm thick mild steel sheet i/c 10x10x1.6mm box beading. sqm 916.0 10.27.4 With 2mm thick fibre reinforced polymer (FRP) sheet i/c 10x10x1.6mm boxbeading. sqm 611.0 10.27.5 With 1mm thick Galvanised steel sheet i/c 10x10x1.6mm box beading. sqm 936.0 10.27.6 With 4mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 750.0 10.27.7 With 6mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 800.0 10.27.8 With 8mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 872.0 132 10.28 10.28.1 With 4.0 mm thick glass panes. sqm 259.0 10.28.2 With 5.5 mm thick glass panes. sqm 262.0 133 10.29 134 11.19 11.19.1 Makrana white second quality. sqm 3051.0 11.19.2 Raj Nagar plain. sqm 1381.0 11.19.3 Agaria White/Morgarh sqm 1882.0 11.19.4 Katni marble sqm 1555.0 11.19.5 Black Zebra. sqm 1315.0 11.19.6 Udaipur / Baroda green marble sqm 1649.0 11.19.7 Pink plain marble. sqm 1448.0 11.19.8 Jaisalmer Yellow sqm 1582.0 135 11.2 11.20.1 Makrana white second quality. sqm 3675.0 11.20.2 Raj Nagar plain. sqm 1932.0 11.20.3 Agaria White/Morgarh sqm 2455.0 11.20.4 Katni marble sqm 2113.0 11.20.5 Black Zebra. sqm 1863.0 11.20.6 Udaipur / Baroda green marble sqm 2211.0 11.20.7 Pink plain marble. sqm 2002.0 11.20.8 Jaisalmer Yellow sqm 2141.0 136 11.21 11.21.1 Makrana white second quality. sqm 3773.0 11.21.2 Raj Nagar plain. sqm 2737.0 11.21.3 Agaria White/Morgarh sqm 2553.0 11.21.4 Katni marble sqm 2219.0 11.21.5 Black Zebra. sqm 1961.0 11.21.6 Udaipur / Baroda green marble sqm 2309.0 11.21.7 Pink plain marble. sqm 2100.0 11.21.8 Jaisalmer Yellow sqm 2240.0 137 11.22 11.22.1 Raj Nagar plain/White Marble/Udaipur Green Marble /Zebra black sqm 1797.0 11.22.2 Granite fine grained dark crystal of other colours and various patterns sqm 2356.0 11.22.3 Granite coarse grained light black/ light red/white with crystal of other colours and various patterns Sqm 2113.0 11.22.4 Granite grey/pink/brown with various patterns Sqm 1808.0 11.22.5 Cuddpah stone sqm 1279.0 138 11.23 139 11.24 140 11.25 141 11.29 11.29.1 Area of slab over 0.50 sqm 11.29.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2919.0 11.29.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2675.0 11.29.1.3 Gray/Pink/Brown or equivalent with various patterns sqm 2370.0 11.29.2 Area of slab upto 0.50 sqm 11.29.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2705.0 11.29.2.2 Coarse grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2486.0 11.29.2.3 Gray/Pink/Brown or equivalent with various patterns sqm 2212.0 142 11.3 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2642.0 11.30.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2422.0 11.30.1.3 Gray/Pink/Brown or equivalent with various patterns sqm 2153.0 11.30.2 Area of slab upto 0.50 sqm 11.30.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2455.0 11.30.2.2 Coarsegrained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2258.0 11.30.2.3 Gray/Pink/Brown or equivalent with various patterns sqm 2011.0 patterns 143 11.32 144 11.33 11.33.1 Flamed Finish Granite sqm 2542.0 11.33.2 Leather Finish Granite sqm 2809.0 145 11.34 146 11.36 Note: - Deduction shall be made for not mirror polishing according to item no 11.43 147 11.37 148 11.38 11.38.1 10-12 mm thick sqm 1177.0 11.38.2 20 mm thick sqm 1231.0 149 11.39 150 11.4 11.40.1 Marble work meter 164.0 11.40.2 Granite work. meter 269.0 151 11.41 152 11.42 153 11.43 154 11.44 11.44.1 Red sand stone sqm 578.0 11.44.2 White sand stone sqm 578.0 11.44.3 Grey lime stone sqm 578.0 11.44.4 Kota stone sqm 678.0 155 11.47 156 11.48 157 11.49 158 11.52 159 11.53 160 11.54 161 11.55 162 11.56 163 12.63 11.63.1 Fastener with threaded dia 6 mm. each 25.0 11.63.2 Fastener with threaded dia 10 mm. each 29.0 11.63.3 Fastener with threaded dia 12 mm. each 46.0 164 11.66 165 11.72 proper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction byusing plate vibrator, filling the joints with sand and cutting of paver blocks as per required sizeand pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in-Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade sqm 805.0 11.72.2 60 mm thick C.C. paver block of M-35 grade sqm 680.0 11.72.3 60 mm thick C.C. paver block of M-30 grade sqm 605.0 166 11.75 including fixing of granite stone door frame with epoxy resin based adhesive including secured to the backing by means of cramps, drilling of hole with rawl plugs and screws 75mm long cleaning etc. complete. Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, towerboltetc complete at all levels as per instruction of Engineer-in-Charge. 11.75.1 Granite Door frame for 100mm thick wall Thickness. metre 1010.0 11.75.2 Granite Door frame for 200mm thick wall Thickness. metre 1512.0 167 11.76 11.76.1 Plain ivory light shade sqm 950.0 Size 600X600mm thickness 9-10mm 11.76.2 Dark shade (terracotta) sqm 1033.0 Size 600X600mm thickness 9-10mm 168 11.77 11. 77.1 Plain ivory light shade sqm 940.0 Size 600X600mm thickness 9-10mm 11. 77.2 Dark shade (terracotta) sqm 1022.0 Size 600X600mm thickness 9-10mm 169 11.8 11.80.1 In light colour and shades as ivory, beige blanco, grey etc. 11.80.1.1 (a) Size 300X300 mm thickness 9-10 mm sqm 934.0 11.80.1.2 (b) Size 600X600mm thickness 9-10mm sqm 1206.0 11.80.1.3 (c) Size 600X600 mm thickness 11-12mm (to be used heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) sqm 1349.0 11.80.2 In dark colour and shade etc. 11.80.2.1 (a) Size 300X300 mm thickness 9-10 mm sqm 946.0 11.80.2.2 (b) Size 600X600mm thickness 9-10mm sqm 1340.0 11.80.2.3 (c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) sqm 1546.0 170 11.81 11. 81.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 81.1.1 (a) Size 300X300 mm thickness 9-10 mm sqm 923.0 11. 81.1.2 (b) Size 600X600mm thickness 9-10mm sqm 1196.0 11. 81.2 In dark colour and shades etc. 11. 81.2.1 (a) Size 300X300 mm thickness 9-10 mm sqm 935.0 11. 81.2.2 (b) Size 600X600mm thickness 9-10mm sqm 1329.0 171 11.82 11. 82.1 For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) 11. 82.1.1 Size 600X600 mm thickness 9-10 mm sqm 1140.0 11. 82.1.2 Size 800X800mm thickness 9-10 mm sqm 1261.0 11. 82.1.3 Size 800X1600mm thickness 9-10 mm sqm 1489.0 11. 82.1.4 Size 1000X1000mm thickness 9-10 mm sqm 1388.0 11. 82.1.5 Size 600X1200 mm thickness 9-10 mm sqm 1235.0 11. 82.1.6 Size 800X1200 mm thickness 9-10 mm sqm 1450.0 11. 82.1.7 Size 1200X1200 mm thickness 9-10 mm sqm 1596.0 11. 82.1.8 Size 1200X1800mm thickness 9-10 mm sqm 1715.0 11. 82.1.9 Size 1200X2400 mm thickness 9-10 mm sqm 2403.0 172 11.83 11. 83.1 For skirting, riser, dado and wall lining etc.glossy/ rustic /stain/mattfinished in all colours and shades 11. 83.1.1 Size 300X600 mm thickness 9-10 mm sqm 1048.0 11. 83.1.2 Size 600X600 mm thickness 9-10 mm sqm 1129.0 11. 83.1.3 Size 800X800mm thickness 11-12mm sqm 1250.0 11. 83.1.4 Size 600X1200 mm thickness 11-12mm sqm 1224.0 11. 83.1.5 Size 800X1200 mm thickness 11-12mm sqm 1440.0 173 11.84 11. 84.1 Area of tiles not less 0.18 sqm 11. 84.1.1 Fine granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter sqm 2296.0 11. 84.1.2 Course granite light Black/light Red/ off White with crystals of other colors and various patterns sqm 2113.0 11. 84.1.3 Gray/Pink/Brown with various patterns sqm 1879.0 174 11.85 11. 85.1 Area of tiles not less 0.18 sqm 11. 85.1.1 Fine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter sqm 1775.0 11. 85.1.2 Coarse grained granite light Black/light Red/ off White with crystals of other colors and various patterns sqm 1610.0 11. 85.1.3 Gray/Pink/Brown with various patterns sqm 1404.0 175 11.97 Size 800X1600 mm thickness 8-9 mm Sqm 1778.0 176 11.102 177 11.103 178 12.4 12.4.1 0.80mm thick with zinc coating not less than 275gm/m² meter 500.0 12.4.2 0.63mm thick with zinc coating not less than 275gm/m² meter 431.0 179 12.7 12.7.1 0.80mm thick with zinc coating not less than 275gm/m² meter 459.0 12.7.2 0.63mm thick with zinc coating not less than 275gm/m² meter 402.0 180 12.12 12.12.1 Corrugated serrated adjustable ridges meter 367.0 12.12.2 Plain wing adjustable ridges meter 311.0 12.12.3 Close fitting adjustable ridges meter 420.0 12.12.4 Unserrated adjustable hips meter 506.0 181 12.13 12.13.1 Corrugated apron pieces meter 340.0 12.13.2 Eaves filler pieces meter 232.0 12.13.3 North light curves meter 500.0 12.13.4 ventilator curves meter 622.0 12.13.5 Barge boards meter 623.0 12.13.6 Ridge finials pair 229.0 12.13.7 Special north light curves each 753.0 12.13.8 S type louvers meter 418.0 182 12.14 183 12.15 primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 184 12.16 12.16.1 Ridges plain (500 - 600mm). meter 320.0 12.16.2 Flashings/ Aprons.( Upto 600 mm) meter 284.0 12.16.3 North light curves. meter 341.0 12.16.4 Barge board (Upto 300 mm) meter 274.0 12.16.5 Crimp curve sqm 315.0 12.16.6 Gutter. (600 mm over all girth) meter 781.0 185 12.17 12.17.1 2mm thick corrugated (2.5 or 4.2 or 6) or step-down (2or 3or 6) as specified. sqm 1031.0 12.17.2 2mm thick flat. sqm 955.0 186 12.23 187 12.24 188 12.26 189 12.27 190 12.32 12.32.1 75 mm diameter (minimum wall thickness 1.8mm) metre 136.0 12.32.2 110 mm diameter (minimum wall thickness 2.2mm) metre 238.0 191 12.33 12.33.1 Coupler 12.33.1.1 75 mm (minimum wall thickness 1.8mm) each 67.0 12.33.1.2 110 mm (minimum wall thickness 2.2mm) each 102.0 12.33.2 Single push fit Coupler : 12.33.2.1 75 mm (minimum wall thickness 1.8mm) each 121.0 12.33.2.2 110 mm (minimum wall thickness 2.2mm) each 94.0 12.33.3 Single tee with door 12.33.3.1 75x75x75 mm (minimum wall thickness 1.8mm) each 106.0 12.33.3.2 110x110x110 mm (minimum wall thickness 2.2mm) each 176.0 12.33.4 Single tee without door 12.33.4.1 75x75x75 mm (minimum wall thickness 1.8mm) each 106.0 12.33.4.2 110x110x110 mm (minimum wall thickness 2.2mm) each 163.0 12.33.5 Bend 87.5° 12.33.5.1 75 mm bend (minimum wall thickness 1.8mm) each 78.0 12.33.5.2 110 mm bend (minimum wall thickness 2.2mm) each 112.0 12.33.6 Shoe (Plain) 12.33.6.1 75 mm Shoe (minimum wall thickness 1.8mm) each 69.0 12.33.6.2 110 mm Shoe (minimum wall thickness 2.2mm) each 99.0 192 12.34 12.34.1 75 mm (minimum wall thickness 1.8mm) each 97.0 12.34.2 110 mm (minimum wall thickness 2.2mm) each 114.0 hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in adirection perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.58.1 10mm thick plaster of Paris (gypsum anhydrous) sheet 10mm thick pop board. 12.58.1.1 Flat surfaces sqm 676.0 12.58.1.2 Curved surfaces sqm 748.0 12.58.1.3 Sunk or raised mouldings sqm 175.0 12.58.1.4 Extra for providing in the plaster of Paris (Gypsum anhydrous) ceiling above 5 metre height from floor level. sqm per meter height 59.0 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.1 Plain board conforming to IS: 2095- Part I: 2011 (Board with BIS certification marks). sqm 750.0 12.58.2.2 Fire resistant Glass ReinforcedGypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) sqm 866.0 12.58.2.3 12.5mm thick moisture resistant gypsum plasterboards Moistbloc as per BS EN 520 confirming to water absorption class H1 with total water absorption < 5%, Green Pro certified by CII sqm 920.0 12.58.2.4 Fully Perforated Gypsum Plaster Board having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturersspecification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. sqm 1277.0 12.58.3 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured throughautoclaving process. sqm 1150.0 193 13.1 13.1.1 1:4 (1 cement : 4 sand) sqm 173.0 13.1.2 1:6 (1 cement : 6 sand) sqm 160.0 194 13.2 13.2.1 1:4 (1 cement : 4 sand) sqm 184.0 13.2.2 1:6 (1 cement : 6 sand) sqm 168.0 195 13.3 13.3.1 1:4 (1 cement : 4 sand) sqm 245.0 13.3.2 1:6 (1 cement : 6 sand) sqm 225.0 196 13.4 13.4.1 1:3 (1 cement : 3 sand) sqm 210.0 13.4.2 1:4 (1 cement : 4 sand) sqm 203.0 197 13.5 13.5.1 1:3 (1 cement : 3 sand) sqm 236.0 13.5.2 1:4 (1 cement : 4 sand) sqm 220.0 198 13.13 199 13.14 200 13.15 13.15.1 Exterior walls of height more than 10 m from ground for every additional height of 3 m or part thereof sqm 34.0 13.15.2 Interior walls of height more than 6 m from floor level for every additional height of 3 m or part thereof sqm 22.0 201 13.16 13.16.1 In one coat sqm 11.0 13.16.2 In two coats sqm 18.0 202 13.17 13.17.1 In one coat sqm 158.0 13.17.2 In two coats sqm 260.0 203 13.18 13.18.1 Spherical ceiling sqm 42.0 13.18.2 Groined ceiling sqm 47.0 13.18.3 Flewing soffits sqm 28.0 204 13.38 205 13.39 13.39.1 Providing and applying plaster of paris punning of 10 mm average thickness over plastered surface to prepare the surface even and smooth complete. sqm 130.0 13.39.2 Extra for making 12mm flute grove with 6 mm depth to prepare the surface even and smooth complete. metre 70.0 206 13.41 207 13.43 208 13.44 209 13.45 210 13.46 211 13.47 13.47.1 One coat. sqm 20.0 13.47.2 Two coats. sqm 32.0 212 13.48 13.48.1 One coat. sqm 37.0 13.48.2 Two coats. sqm 56.0 213 13.49 214 13.51 215 13.52 216 13.53 217 13.54 218 13.54.1 219 13.54.2 220 13.54.3 221 13.55 13.55.1 One coat sqm 63.0 13.55.2 Two coats sqm 101.0 222 13.64 223 13.65 224 13.66 13.66.1 One coat. sqm 35.0 13.66.2 Two coats. sqm 53.0 225 13.68 226 13.71 227 13.77 228 13.8 13.80.1 0.8-1.2mm thickness sqm 368.0 13.80.2 2.0-2.5mm thickness sqm 338.0 229 13.81 effective for 90 Days(03 Months) . 230 13.103 Note:- Applicable to item No. 13.1 to item No. 13.10 231 13.105 13.105.1 Standard pattern and design wallpaper Sqm 615.0 13.105.2 3D pattern and design wallpaper Sqm 750.0 13.105.3 Customize design wallpaper Sqm 1145.0 232 14.5 14.5.1 Float glass panes of thickness 4 mm sqm 679.0 14.5.2 Float glass panes of thickness 5.5 mm sqm 759.0 233 14.6 14.6.1 Float glass panes of thickness 4 mm sqm 801.0 14.6.2 Float glass panes of thickness 5.5 mm sqm 882.0 234 14.7 14.7.1 Float glass panes of thickness 4 mm sqm 697.0 14.7.2 Float glass panes of thickness 5.5 mm sqm 778.0 235 14.8 14.8.1 2nd class teak wood fillets meter 30.0 14.8.2 Haldu/Bija/Kail wood fillets. meter 26.0 236 14.11 237 14.24 238 14.27 239 14.28 240 14.29 241 14.31 242 14.36 243 14.37 244 14.38 245 14.39 246 14.48 247 14.49 14.49.1 Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 liters/10 sqm complete including cost of Priming coat. sqm 42.0 14.49.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. sqm 30.0 248 14.51 14.51.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). sqm 87.0 14.51.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm). sqm 52.0 249 14.52 14.52.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. sqm 65.0 14.52.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm). sqm 41.0 250 14.53 14.53.1 One or more coats applied on walls @ 0.85 ltr/10 sqm. sqm 58.0 251 14.62 14.62.1 (one or more coats) sqm 9.0 14.62.2 (two or more coats) sqm 11.0 252 15.2 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). cum 578.0 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). cum 356.0 253 15.6 15.6.1 In lime mortar with old mughal bricks. cum 421.0 15.6.2 In lime mortar. cum 202.0 15.6.3 In cement mortar. cum 487.0 254 15.7 15.7.1 From brick work in lime mortar. 1000 nos 1254.0 15.7.2 From brick work in cement mortar. 1000 nos 1560.0 255 15.8 15.8.1 In lime mortar. cum 275.0 15.8.2 In cement mortar. cum 582.0 256 15.13 257 15.14 15.14.1 Of area 3 sq. metres and below. each 85.0 15.14.2 Of area beyond 3 sq. metres. each 117.0 258 15.15 15.15.1 Of area 3 sq. metres and below. each 33.0 15.15.2 Of area beyond 3 sq. metres. each 44.0 259 15.47 260 15.48 261 15.49 262 15.51 15.51.1 Rectangular manhole 90x80 cm and 45 cm deep each 611.0 15.51.2 Rectangular manhole 120x90 cm and 90 cm deep. each 1069.0 15.51.3 Rectangular arch type manhole 140x90cm and 2.45m deep. each 2023.0 15.51.4 Circular manhole 122 cm diameter and 1.68 m deep each 1553.0 263 15.52 15.52.1 Rectangular manhole 90x80 cm and beyond 45 cm depth. each 486.0 15.52.2 Rectangular manhole 120x90 cm and beyond 90 cm depth. each 579.0 15.52.3 Rectangular arch type manhole 140x90 cm and beyond 2.45m deep (upto 4.25 m depth). each 468.0 15.52.4 Circular manhole 122 cm diameter and beyond 1.68 m deep (upto 2.29 m depth). each 322.0 264 15.64 265 17.1 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. each 2995.0 266 17.2 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid. each 3036.0 17.2.2 W.C. pan with ISI marked black solid plastic seat and lid. each 3013.0 267 17.3 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. each 4613.0 17.3.2 W.C. pan with ISI marked black solid plastic seat and lid. each 4590.0 268 17.11 17.11.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. each 2187.0 17.11.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar tap. each 1938.0 17.11.4 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. each 1664.0 17.11.5 White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap. each 1775.0 269 17.12 270 17.14 17.14.1 Kitchen sink with drain board 17.14.1.1 510x1040 mm bowl depth 250mm. each 8074.0 17.14.1.2 510x1040 mm bowl depth 225mm. each 7609.0 17.14.1.3 510x1040 mm bowl depth 200mm. each 7493.0 17.14.1.4 510x1040 mm bowl depth 178mm. each 5286.0 17.14.2 Kitchen sink without drain board 17.14.2.1 610x510 mm bowl depth 200 mm. each 4583.0 17.14.2.2 610x460 mm bowl depth 200 mm. each 4351.0 17.14.2.3 470x420 mm bowl depth 178 mm. each 3422.0 271 17.22 17.22.1 White each 945.0 17.22.2 coloured each 1037.0 272 17.24 17.24.1 White each 456.0 17.24.2 Black each 433.0 17.24.3 Coloured (other than black and white) each 688.0 273 17.25 274 17.6 17.60.1 75 mm each 33.0 17.60.2 110 mm each 50.0 275 17.61 276 17.64 17.64.1 Semi rigid pipe 17.64.1.1 32 mm dia each 87.0 17.64.1.2 40 mm dia each 98.0 17.64.2 Flexible pipe (only in residential & complaxes) 17.64.2.1 32 mm dia each 87.0 17.64.2.2 40 mm dia each 98.0 277 17.65 278 17.67 279 17.67 17.68.1 Circular shape 450mm dia. each 806.0 17.68.2 Rectangular shape 453x357mm each 642.0 17.68.3 Oval shape 450x350mm (outer dimensions) each 697.0 17.68.4 Rectangular shape 1500x450 mm each 1311.0 280 17.69 281 17.7 17.70.1 C.P. brass each 340.0 17.70.2 Vitreous china each 324.0 282 17.74 283 17.75 284 17.76 285 18.6 18.6.1 Internal work - Exposed on wall 18.6.1.1 15 mm nominal outer dia .Pipes metre 129.0 18.6.1.2 20 mm nominal outer dia .Pipes metre 153.0 18.6.1.3 25 mm nominal outer dia .Pipes metre 177.0 18.6.1.4 32 mm nominal outer dia .Pipes metre 254.0 18.6.1.5 40 mm nominal outer dia .Pipes metre 354.0 18.6.1.6 50 mm nominal outer dia .Pipes metre 528.0 18.6.2 Concealed work including cutting chases and making good the walls etc. 18.6.2.1 15 mm nominal outer dia .Pipes metre 207.0 18.6.2.2 20 mm nominal outer dia .Pipes metre 234.0 18.6.2.3 25 mm nominal outer dia .Pipes metre 288.0 18.6.2.4 32 mm nominal outer dia .Pipes metre 360.0 286 18.7 External Work 18.7.1 15 mm nominal outer dia .Pipes metre 122.0 18.7.2 20 mm nominal outer dia .Pipes metre 141.0 18.7.3 25 mm nominal outer dia .Pipes metre 185.0 18.7.4 32 mm nominal outer dia .Pipes metre 238.0 18.7.5 40 mm nominal outer dia .Pipes metre 324.0 18.7.6 50 mm nominal outer dia .Pipes metre 498.0 18.7.7 62.50 mm nominal inner dia .Pipes. metre 1429.0 18.7.8 75 mm nominal inner dia .Pipes. metre 2018.0 18.7.9 100mm nominal inner dia .Pipes. metre 2791.0 18.7.10 150 mm nominal inner dia .Pipes. metre 3358.0 287 18.13 18.13.1 25 mm nominal bore each 428.0 18.13.2 32 mm nominal bore. each 500.0 18.13.3 40 mm nominal bore each 584.0 18.13.4 50 mm nominal bore each 749.0 288 18.14 18.14.1 15 mm nominal bore each 316.0 18.14.2 20 mm nominal bore each 431.0 18.14.3 25 mm nominal bore each 499.0 289 18.17 18.17.1 30 cm length 18.17.1.1 15 mm nominal bore each 88.0 18.17.1.2 20 mm nominal bore each 129.0 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore each 149.0 18.17.2.2 20 mm nominal bore each 184.0 290 18.18 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. each 916.0 18.18.2 With well burnt flyash bricks of 50 kg/sqm compressive strength. each 870.0 291 18.28 292 18.29 18.29.1 15 mm nominal bore each 306.0 18.29.2 20 mm nominal bore each 338.0 293 18.3 18.30.1 15 mm nominal bore each 318.0 18.30.2 20 mm nominal bore each 344.0 294 18.31 295 18.32 296 18.33 297 18.34 298 18.35 299 18.36 300 18.37 301 18.38 302 18.39 303 18.41 304 18.42 305 18.43 18.43.1 100 mm diameter each 806.0 18.43.2 150 mm diameter each 922.0 18.43.3 200 mm diameter each 1336.0 306 18.64 307 18.65 308 18.67 309 18.68 18.68.1 300 mm long each 450.0 18.68.2 600 mm long each 650.0 310 19.4 19.4.1 110 mm diameter OD (min. wall thickness 3.2mm) metre 234.0 19.4.2 160 mm diameter OD (min. wall thickness 4.0 mm) metre 477.0 19.4.3 200 mm diameter OD (min. wall thickness 4.9 mm) metre 751.0 19.4.4 250 mm diameter OD (min. wall thickness 6.2mm) metre 972.0 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) metre 1232.0 311 19.5 19.5.1 110 mm diameter PVC. pipe metre 576.0 19.5.2 160 mm diameter PVC. pipe metre 704.0 19.5.3 200 mm diameter PVC. pipe metre 821.0 19.5.4 250 mm diameter PVC. pipe metre 949.0 19.5.5 300 mm diameter PVC pipe metre 1078.0 312 19.6 19.6.1 110 mm diameter PVC. pipe metre 274.0 19.6.2 160 mm diameter PVC. pipe metre 444.0 19.6.3 200 mm diameter PVC. pipe metre 521.0 19.6.4 250 mm diameter PVC. Pipe metre 607.0 19.6.5 300 mm diameter PVC pipe metre 700.0 313 19.7 19.7.1 100x100 mm size P type 19.7.1.1 With well burnt bricks each 1764.0 19.7.1.2 With Sewer bricks conforming to IS : 4885 each 1668.0 19.7.2 150 x 100 mm size P type. 19.7.2.1 With well burnt bricks each 1803.0 19.7.2.2 With sewer bricks conforming to IS : 4885 each 1707.0 19.7.3 180x150 mm size P type 19.7.3.1 With well burnt bricks each 1913.0 19.7.3.2 With Sewer bricks conforming to IS : 4885 each 1818.0 314 19.9 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks each 7997.0 19.9.1.2 With Sewer bricks conforming to IS : 4885 each 7747.0 19.9.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight offrame 58 kg) : 19.9.2.1 With well burnt bricks each 18086.0 19.9.2.2 With Sewer bricks conforming to IS : 4885 each 17402.0 19.9.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) 19.9.3.1 With well burnt bricks each 21816.0 19.9.3.2 With Sewer bricks conforming to IS : 4885 each 21228.0 315 19.1 19.10.1 Size 90x80 cm 19.10.1.1 With well burnt bricks metre 6176.0 19.10.1.2 With Sewer bricks conforming to IS : 4885 metre 5448.0 19.10.2 Size 120x90 cm 19.10.2.1 With well burnt bricks metre 7380.0 19.10.2.2 With Sewer bricks conforming to IS : 4885 metre 6512.0 316 19.12 19.12.1 With well burnt bricks metre 5257.0 19.12.2 With Sewer bricks conforming IS : 4885 metre 4648.0 317 21.1 21.1.1 For fixed portion. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) kg 378.0 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 416.0 21.1.1.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron) kg 426.0 21.1.2 For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings whereverrequired including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) kg 446.0 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 484.0 21.1.2.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron) kg 494.0 21.1.3 Deduct for not providing EDPM rubber/neoprene gasket all around. kg 80.0 318 21.2 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. sqm 802.0 21.2.2 Pre-laminated particle board with decorative lamination on both sides. sqm 907.0 319 21.3 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) sqm 774.0 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than sqm 948.0 12.50 kg/sqm ) 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). sqm 1182.0 320 21.5 21.5.1 With stainless steel cover plate - minimum 1.25 mm thickness each 1890.0 21.5.2 With brass cover plate - minimum 1.25 mm thickness. each 2072.0 321 21.16 21.16.1 Anodized (AC15 ) aluminium each 62.0 21.16.2 Powder coated minimum thickness 50 micron aluminium each 65.0 21.16.3 Polyester powder coated minimum thickness 50 micron aluminium. each 69.0 322 21.17 323 21.18 324 21.19 325 21.21 326 21.22 327 21.23 328 21.24 329 21.32 330 22.6 a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. 331 22.14 22.14.1 Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cum 6569.0 22.14.2 Cement mortar 1:3 (1 cement : 3 sand) cum 9308.0 22.14.3 Cement mortar 1:4 (1cement : 4 sand) cum 8437.0 332 25.1 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440X575X250mm With integral foot rests. (Premium Range) each 4726.0 25.1.2 White Vitreous china Anti germ Fluoro-Polymer coated Orissa pattern W. C. pan of size 410X515X255 mm with integral foot rests.(Premium Range) each 4392.0 333 25.2 25.2.1 Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan Size 360X545X395 with solid poly propelyne made soft closing seat cover (Premium Range) each 9788.0 25.2.2 Anti-germ Fluoro-Polymer Coated Water Closet European type W. C. pan size 360X475X395 mm with solid poly propelyne made soft closing seat cover (Premium Range) each 8742.0 334 25.3 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380X520X375 mm with solid poly propelyne made soft closing seat cover (Premium Range) each 26412.0 25.3.2 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 390X570X365 mm with solid poly propelyne made, soft closing seat cover (Premium Range) each 23559.0 25.3.3 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500 x 330mm with solid poly propelyne made, soft closing seat cover (Premium Range) each 21099.0 25.3.4 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500 x 330mm or greater size with solid poly propelyne made, soft closing seat cover (Premium Range) each 18838.0 335 25.4 25.4.1 Anti germ Fluoro-Polymer Coated couple water closet Size 420X710X810mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 28103.0 25.4.2 Anti germ Fluoro-Polymer Coated couple water closet Size 380X610X805mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 19275.0 25.4.3 Anti germ Fluoro-Polymer Coated couple water closet Size 370 x 640 x 760mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 18952.0 25.4.4 Anti germ Fluoro-Polymer Coated couple water closet Size 375X650X800 mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 18023.0 336 25.5 25.5.1 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) Each 34317.0 25.5.2 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 25954.0 25.5.3 Anti germ Fluoro-Polymer Coated Single PieceW.C. Pan Size 385X720X710mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 22237.0 25.5.4 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 19450.0 337 25.6 25.6.1 Anti germ Fluoro-Polymer Coated extended wall hung type couple closet Size 380X650X730mm with solid poly propelyne made soft closing seat cover (Premium Range) each 13365.0 25.6.2 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet Size 375X360X750mm along with dual flushing cistern flushing capacity 3 & 6 litre. (Premium Range) each 10670.0 338 25.7 25.7.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595X435X185 mm with basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) each 16581.0 339 25.8 25.8.1 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570x415x200mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system with square wall flance & spout complete (decol technology). (Premium Range) each 14543.0 25.8.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570X820X195mm with 15 mm C. P. Table Top pressmatic Pillar cock auto closing system (decol technology). (Premium Range) each 13614.0 340 25.9 25.9.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range) each 15591.0 25.9.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 600x400x185mm with 15 mm C. P. wall mounted single lever concealed basin mixture. (Premium Range) each 14940.0 341 25.1 25.10.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185mm with Table mounted single lever Tall boy basin mixture, (cartridge size 32mm.) (Premium Range) each 18585.0 25.10.2 White vitreous china type Anti germ fluoro- polymer coated counter top wash basin Size 530x420x140mm with tall boy basin mixture, (cartridge size 32 mm). (Premium Range) each 16785.0 342 25.11 25.11.1 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm. (Premium Range) each 14544.0 25.11.2 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal size 475X315X715 mm top inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) with 15mm Brass made Pressmatic auto closing open urinal flush valve with wall flange (Decol technology, 400000 operation warranted) complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : each 13336.0 25.11.3 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal back inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) Size 385X325X635 mm with Concealed sensotronic flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : URS-WHT-13253N & PRS-CHR-073 each 10641.0 343 25.12 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve battery & electrical oprated type (9V transformer) for urinal complete set with installation box with control cock. (Premium Range) each 23927.0 25.12.2 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385x325x635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range) each 20025.0 344 25.13 25.13.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 480 X 300X740 mm with 15mm Brass made pressmatic auto closing concealed urinal flush valve with wall flange (Decol technology, 400000 operation warranted). (Premium Range) each 18491.0 345 25.14 346 25.14.1 25.14.2 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated Urinal size 475x315x715 mm (Inbuilt spreaders, bottle trap and ceramic waste coupling) with inbuilt sensor battery & electrical oprated type (9V transformer) for flushing. (Premium Range) each 22998.0 347 25.15 348 25.16 349 25.17 350 25.18 351 25.19 352 25.21 353 25.22 354 25.23 355 25.24 356 25.25 357 25.26 358 25.27 359 25.28 360 25.29 361 25.31 362 25.32 363 25.33 364 25.34 365 25.35 366 25.36 367 25.37 368 25.38 369 25.39 370 25.41 371 25.42 372 25.43 373 25.44 374 25.45 375 25.46 376 25.47 377 25.48 378 25.49 379 25.51 380 25.52 381 25.53 382 25.54 383 25.55 384 25.56 385 25.57 386 25.58 387 25.59 388 25.61 389 25.62 390 25.63 vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, C. P. brass single lever basin mixer, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.63.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) each 14729.0 25.63.2 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 570x470x190 mm. (Premium Range) each 15100.0 25.63.3 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 495x400x365 mm. (Premium Range) each 18490.0 391 25.64 25.64.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) each 10617.0 Note- Schedule of items includes all the items required for maintainance of buildings regarding A/R, S/R MOW, Deposit & Other Works as per SCHEDULE OF RATES FOR BUILDING WORKS inforce from 01/01/2024, issued by Project Director, Public Works Department (PIU) M.P. Bhopal. Sub Engineer Sub Divisional OfficerSurvey Sub Division.P.W.D. Bhopal Executive EngineerMaintanance Division No.2P.W.D. Bhopal
Contract Date: Apr 23, 2026 Contract Value : 21.93 Lakh
Government Departments No of Bidders 5
Madhya Pradesh View Result →
8.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
9.
Housing Urban and Rular Development #11286216 AOC
Tender For Construction Of New Primary Health Center (Phc New Bldg) At Perumalmalai H/O Adukkam, Kodaikanal Block.; 2 Clearing lightjungle vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 3 Earthwork excavation for foundation (for narrow excavation) to full depth as per designed in all soils and sub soils except soft disintegrated rock not requiring blasting and hard rock requiring blasting and bailing water wherever necessary. 4 Supplying and filling in foundations and basement with fillingM sand in layers not exceeding 15 cm. thick, well watered ,rammed and consolidated etc. complete complying with standard specifications. 5 Plain Cement Concrete 1 : 4 :8 ( one part of cement, four parts of sand and eight parts of hard broken stone ) using 40 mm gauge hand broken hard broken granite stone jelly complying with standard specifications in foundations and basement. 6 Refilling the approved good quality earth in plinths, area development etc. wherever specified in layers is not exceeding 200 mm thick, with available earth at site. 7 Supplying and filling of good earth filling locally available earth transported from the outside including consolidation,leveling specifiedin layers of not exceeding 200 mm thick., etc. complete. 8 Supplying and erecting Centering and Shuttering for soffits including necessary supports and strutting up to 3 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification.(Payment for centering shall be given after the concrete is laid). 9 Upto Basement 10 Ground Floor 11 First Floor 12 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement ratio with plasticizer using 20mm and down concrete structural elements under controlled water graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the depart- mental officers comple.-1m3 13 Foundation & Basement 14 Ground Floor 15 First Floor 16 Steel - Fe 500D : Supply, fabrication and placing of reinforcement steel of high yield strength ribbed bars of various diameters and grade conforming to IS 1786 for reinforced concrete work. The work includes recoiling, straightening, cutting, bending, fabricating, and placing in position, at all levels including lead and lift, according to drawings, specifications etc. complete and supply & use of 18G black annealed binding wire double fold to tie the bars in position and providing precast cement/ PVC cover blocks for main reinforcement to ensure specified cover and complete., including all labor charges etc as directed by departmental officers. 17 Brick work in following Cement Mortar 1:5 using best quality Country bricks of size 83/4 x 41/4 X2 3/4 for foundation and basement including curing etc., complete complying with standard specification. Including scaffolding curing cost of reinforcement etc. all complete as per specifications and drawings as directed by the Engineer in-charge. 18 Foundation basement 19 Ground floor 20 First floor 21 Brick partition walls of 11.50cm thickness using best quality Country bricks of size 83/4 x 41/4 X2 3/4in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately). 22 Ground Floor 23 First Floor 24 PLASTERING WORK 25 Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing.The Surface shall then be allowed to dry for atleast 48 hours.It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface.Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete].The Putty shoule be got approved by the Executive Engineer before use on work. 26 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and ThreeM.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers 27 Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or chambering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labor complete in all respects including all lead, lift and descent andas directed. 28 FLOORING AND DADOOING 29 Paving the floor with best quality Vitrified Tiles of size 600 x 600 x 8mm of approved color, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same color pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works).Basic Cost-Rs.776/sq.m 30 Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works).Basic cost-Rs.464/sq.m 31 Dadooing the walls with colouredDadooing Ceramic tiles of size 150mm x 150mm x 6mm approved size , quality and colour set in CM 1 : 2 - 10 mm thk. And pointed with suitable cement including finishing the joint and pointing flesh with walls and tile surfacein all floors at the rate of 0.40 Kg /Sqm etc. complete. 32 Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). 33 Providing, fabricating and fixing M.S. grillsWindows,and ventilator, gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including necessary fixtures complete as per drawings and specifications and as directed by the Engineer. 34 S.S Handrail 35 Manufacturing,supplying and fixing of stainless steel handrails for staircase using 50mm dia 304L grade stainless steel pipe of 1.6mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1mm thick as vertical at 900mm centre with 2 Nos of 25mm dia intermediate horizontal stainless steel pipe of 1.6mm thick in between.The vertical pipe has to be welded to the 100 x 100 x 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance,electrical charges,ect.complete. 36 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete 37 Supply and Fabrication of UPVC doorincluding cost and conveyance of all charges etc complete. 38 Solid PVC door shutters Toilet door using 19 Gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings.The over all size of styles shall be 50mm x 30mm.The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm.The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. 39 UPVC Windowsupplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride) windows of casement type (open) from the profile the size of outer frame 60mmx58mm and shutter profile are reinforcement with g/1mm 125GSMand 100% corrosion free, the profiles are multi chambered sectionwith wall thick of 2mm. The EPDM rubber (black color) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power points locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed or plainglass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and shouldhave key lockable action, security protective hinges, strong lockingsystems and as per sizefor arrestingnoise and energy loss. 40 UPVC VENTILATOR: Supplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride)Louvered Ventilators of from the profile the size of outer frame 60x58mm and shutter profile the size of 60x78mm both profile size of 60x78mm both profiles are reinforced with GI/1MM 125GSMand 100% corrosion free , the profile are multi chambered sections withwall thick of 2mm. The EPDM rubber (black color) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiation pin headed glass 4mm thick should be fixed to the wall with 100% packing with screws and silicon packing all around the frame. The ventilator should be got approved from the Executive Engineer before use on work. 41 PAINTING WORK 42 Painting two coats of synthetic Enamel paint of approved colour and make over one coat of anti corrosive Zinchromite primerover new wood / steel work, suitably prepared for receiving the paint by surface scraping, rubbing applying filler etc. including cost of filler, primer, paint all complete as per drawings and specifications. 43 Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the wallssmooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.(The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work). 44 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 45 Weathering Course Concrete using best quality broken brick jelly of 20 mm uniform gauge in pure slaked lime ( NO Sand to be used ( over the RCC roof slab in the proportion of brick jelly to lime being 32 : 121/2 by volume laid over in single layer and consolidated to the required slope and finished thickness and beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime, jiggery water etc. complete complying with standard specifications and as directed 46 Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 47 Plumbing Work 48 Supplying and fixing of Indus floor mounted white colour European water closet Parryware or equivalent, with seat cover and dual flush (3 & 6 lit) cistern having P trap withseat cover, supplyingnon corrosive hinges, CP bolts, nuts, washers, providing and fixing dash anchor fastners with bolts / L -brackets with anticorrosive paint cutting grooves in masonry or concrete surfaces, groutingwith cement concrete 1:2:4 mix, using 20mm size stone jelly,restoring the damaged portion to their original condition using required materials,fixing the water closet to perfect level,alignment,testingetc.complete. 49 Providing and keeping in stores, shifting to the place of installation, fixing,testing and commissioning ofwhite coloured vitreous china under counterRegular rectangular wash basin with brackets/ G.I. rag bolts and nuts painted,32mm dia brass C.P. waste coupling, (heavy) 32mm diabrassC.P.bottletrap,15mmdiabrassC.P.Anglestopcockwith flange, 15mm dia brass C.P. coldwater connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors- toilets. Wash Basin 50 Supply & Fixingat sitein position 15mm dia C.P brass BIB COCKS long body with wall flangeincludingcuttingandmakinggoodthe wallswhereverrequired 51 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc.,complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 52 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). 53 Supplying and fixing in positionC.P. Soap tray of size 150 x 150mm including cost of teak wood plug and C.P. screws. etc. complete complying with standard specification.(D) 54 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition,including testing for any leakages,etc.,complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). 55 a) 40mm dia. 6kg class PVC pipes. 56 b) 50mm dia. 6kg class PVC pipes. 57 c) 75mm dia. 6kg class PVC pipes. 58 d) 110mm dia. 6kg class PVC pipes. 59 Supplying and fixing in position cost iron Nahini / Floor trap with Stainless steel grating / PVC nahini / Floor Trap with PVC Grating type of size 100 x 75 / 75 x 50 mm with best quality gratings of approved brand fixed over a bed of brick jelly lime concrete 1;2;5 (One lime two sand and five aggregate ) brick jelly 40mm and finishing with cm 1;3(One cement and three sand) including dismantling masonary wherever found necessary and making good to the original condition and giving connections to the cast iron pipe etc, complete complying with standard specififcation and as directed by the departmental Officers. 60 Supply and fixing in position best quality PVC IS 4985 - CLASS-II - 4 Kg/Sqcm -Rain water pipes of various size having ISI mark and providing leak proof joints with such asBend, Tee Junction, door etc.,of approved qualityincluding fixing to the wall with special PVC /MS clamps, etc., and making connection to all sanitary fittings, wherever necessary and making chipping good to the original condition, complying with standard specification etc.,complete. 61 b).110mm dia. 4kg class pipes. 62 Supplying and fixing in position of the following dia PVC rain water gratings for rain water pipes ,of approved quality and varietyof various size confirming to ISS andincluding necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer. 63 110mm dia 64 Supplying and fixing in position of the following dia PVC specials such asPVC vent Cowl etc.,of approved quality and varietyof various size confirming to ISS amend providing leak proof joint etc., including necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer. 65 a)75mm Dia 66 b)110mm Dia 67 PART-C - EXTERNAL DRAINAGE 68 Soil/ Waste Pipes 69 Supply and fixing in position best quality PVC IS 4985 - CLASS- III - 6 Kg/Sqcm -Soil/ waste pipes of various size with approved quality and varietyof various size confirminghaving ISI mark and providing leak proof joints including erection of below groundwith excavation and refilling etc.,and making connection to Manholes /Gully trap,wherever necessary and making chipping good portion to the original condition,complying with standard specification etc., complete. 70 160mm dia. 6kg class III-pipes. 71 Supply, laying and erction of glazed stone ware gully trap (100 x 75 mm) with 100 mm dia, outlet including embedding trap in cement concrete 1:3:6 and constructing chamber of size 300 x 300 mm inside clear in brick masonry 230 mm thick, plaster with water proof cement mortar (1:3) 15 mm thick on both internal and external surfaces inside finished with floating coat of neat cement. The work including excavation to required depth of gully trap and refilling and making good in the surface withProviding and fixing SFRC frame and cover 400 x 400 mm (clear opening) complete complying with std.specification. 72 Supplying and Erection and construction of sewer chambers of required internal dimensions 600x600 upto 0.6 mtr.depth with 230mm brick masonry in C.M.1:5 thk of masonry over bed of1:2:4 R.C.C. 200 mm thk bove 100 mm thk P.C.C.1;3:6 Cement concrete foundations over sand bed of 100mm thk channelling in 1;2:4 cement concrete, plastering in 1:3 cement mortar for internal and external surface finished with floating coat of neat cement, the work including excavation for required depth of gully trap and refilling and making good in the surface with SFRC cover and frame 600x600mm (clear opening)complete complying with standard specifications etc., 73 Construction of rain water recharge well of 1200mm dia and depth upto 1500mm, in addition 110 dia special blue slotted pipe for bore well.pipe should be laid from bottom of ring well centre to below 1500mm as shown in the drawings,including all types of excavation, occur for pipe,filling of rain water harvesting materials with construction of R.C.C. ring and top 100mm RCC SLAB WITH 450X450mm perforated SFRC manhole and 230mm brick wall in 2height with below 300mm lengthx100mm thk P.C.C. as per the structural filling the filter media as per drawing. 74 Supplying and fixing of PVC water storage tank of best approved quality and make of super thick with lid ofcapacity of 2000 litres with accessories including giving necessary connection etc., complete as directed by the departmental officer. (The PVC water storage tank should be got approved by the Engineer before use on work)(TWAD- Pano:173) 75 provision for rainwater harvesting structure 76 Electrification 77 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) 78 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End 79 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End 80 Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.) 81 Supply and fixing of fancy glass shade and 7W / 9W LED bulb 82 Supply and fixing of single box type 440W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS copper leads from terminals to the fitting 83 Supply and fixing of AC / DC 76mm buzzer / call bell suitable for 230 volts 50 c/s single phase AC supply on suitable TW board with push switch 84 Supply and fixing of 1200mm (48) AC ceiling fan complete with stepped electronic 300W regulator with 300mm down 85 Supply and fixing of 300mm (12) sweep (light duty) AC exhaust fan complete without provision of hole in the wall 86 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End 87 Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End 88 Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earthconnection (For AC Plug) 89 Supply and fixing of 8 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 24 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 90 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 91 Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipeconcealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of theconcealed portion with suitable colour 92 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. 93 Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVCrigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitablecolour 94 Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth Wire connection of 6 sq.mm copper wire with painting of suitablecolour 95 Supply and run of 1 of No.8 SWG GI wire for earth connection 96 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earthconnection 97 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm 98 Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2 x 1-1/2 x 1/4 rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1 x 1/4 with inter connection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with 1 No 63 Amp 30 MA Four Pole RCD / RCCB (Lower End) with suitable necessary connection with earth connection complete 99 Supply and fixing of 63A TPNMC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only 100 Supply and fixing of 63A TPNMC switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing 101 Supply and fixing of brass cable gland for 2 x 16 sq.mm. PVC armoured LTUG cable with earth connection 102 Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection 103 Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 104 Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 105 Supply and Laying of 3 1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 106 Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 107 Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 108 Septic Tank 109 Earthwork for foundationsand depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soilincluding excavated earth. 110 Supplying and filling in foundation and basement with M sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification. 111 Laying the Plain Cement concrete 1:4:8(One cement four sand and eight brokenMachine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc.. 112 Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid) 113 REINFORCED CEMENT CONCRETE M25 1:1.5:3 mixusing 20mm machine crushed 20mm gauge hard broken granite stone jelly for all reinforced cement concrete works connected to this work excluding cenetering, shuttering and cost of reinforcement grills placed in position, but including laying, vibrating, curing and finishing, fixing fan clamps in the RCC floor and roof slab works wherever necessary and bearing surfaces of the wall at the sides and bottom of the slab, beams shall be finished smooth with cement mortar 1:3 (One cement and three sand ) and Kraft paper laid without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers. 114 Brick work in following Cement Mortar using best quality of Country Bricks of size 8-3/4 x 4-1/4 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 115 Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally and externally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or champhering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labour complete in all respects including all lead, lift and descent andas directed. 116 Supplying and fixing in position C.I.Manhole covers (heavy duty) mof various sizes of best approved quality and as per standard specificationsetc., complete.0.6X0.6M Size etc., complete. 117 Providing, machine mixing and laying on the P.C.C/ R.C.C. surface in approved panels of25 mm thick granolithic flooring in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 10 to 12 mm thick)well vibrated,compacted including 45 X 3 mm glass dividing strip, fixed to correct level and finished smooth and cured by keeping surfaces well-covered and protected against excess of an type. (The contractor to provide for preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond and any curling, lifting or beybonding noticed shall be rectified by the contractor at his cost). 118 Supplying, fabricating and placing in position mild steel/Ribbed tor steel rods for all RCC works including cost of steel and binding wire also in all floors, complete complying with standard specfication. 119 Under Ground Sump 120 Earthwork for foundationsand depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soilincluding excavated earth. 121 Supplying and filling in foundation and basement with M sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification. 122 Laying the Plain Cement concrete 1:4:8(One cement four sand and eight brokenMachine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc.. 123 Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid) 124 Reinforced Cement Concrete 1:11/2:3 (One Cement, One and a half sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers 125 Providing and applying 10 mm thick Cement plaster in Cement mortar 1:3 ( One part of Cement and Three parts of Sand ),to finishing the exposed surfaces of R.C.C. items of works such as Roof (or) floor slabs, beams,and Sun shades etc.to correct plane and l 126 Providing, machine mixing and laying on the P.C.C/ R.C.C. surface in approved panels of 25 mm thick granolithic flooring in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 10 to 12 mm thick)well vibrated,compacted including 45 X 3 mm glass dividing strip, fixed to correct level and finished smooth and cured by keeping surfaces well-covered and protected against excess of an type. (The contractor to provide for preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond and any curling, lifting or beybonding noticed shall be rectified by the contractor at his cost) 127 Supplying and fixing in position C.I.Manhole covers (heavy duty) of various sizes of best approved quality and as per standard specificationsetc.,complete.0.6X0.6M Size etc., complete. 128 PVC mould CI steps for sump 129 Supplying, fabricating and placing in position mild steel/Ribbed tor steel rods for all RCC works including cost of steel and binding wire also in all floors, complete complying with standard specfication. 130 Aluminium ladder for maintenance over the Roof top 131 Provision for lab interior 132 Tactile Flooring and Braille Sign Board 133 Provision for Sitting bench and Cubboard Arrangements 134 GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column BB for all works in this package}
Contract Date: Jun 13, 2026 Contract Value : 1.68 Crore
Local Bodies No of Bidders 2
10.
Tourism #11266721 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Jul 03, 2026 Contract Value : 5.42 Crore
Government Departments No of Bidders 2
11.
Housing Urban and Rular Development #11229363 AOC
Misc. Repairs And Other Civil Works Of Tiles, Doors, Windows,Wooden Flooring, Shed And Internal And External Painting In C.M. Bunglow Civil Line Nagpur.(Only For Society).-= 1 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand 2 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 3 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. 4 Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 1190 to 1202 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring 5 Providing and laying Vitrified MATT finishhaving decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical andconfirmingtoIS15622-2006(GroupBla)ofapprovedmakeshadeandpatternfor flooringinrequiredpositionlaidonabedofbondingchemicalfillingjointscuringand cleaning etc .complete. 6 Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. 7 Providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 8 Providing and fixingTable top white wash basin of size 120x635x405mm rubber plugs and brass chain, withpillar cock, C.P.Angular stop cock long thread, continentalincluding S.S. bottle trap of approved make havingnecessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. 9 ProvidingandapplyingTextureplasterwithfinishingwithtexturematerial ofapproved makein 3 to 4 millimeterthickness on previously plastered surface, including Plaster Groove 6mmthicknessorTapeGrooves35to45mmthicknessorasrequired,inallposition including preparing the surface, scaffolding etc. complete. 10 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box 11 Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand. 12 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm 13 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 14 Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etccomplete 15 Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete.b) Granite 16 Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. 17 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. 18 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc.as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.Spec. No. : As directed by Engineer-in-charge. 19 Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors/windows including providing and fixing clips, putty etc. complete. (a) 2.00 mm thick. 20 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. 21 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. 22 Removing W.C. Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the service-able materials as and where directed includingthrowing the unserviceable materials out side etc. complete. 23 Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 24 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. 25 Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. 26 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 27 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 28 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 29 Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 30 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 31 Providing and fixing C.P. BIB cock with wall flange jaquar or equivalent make continental (CAT.NO. CON-047) including necessary sockets/ union nut etc. complete. 32 Providing and fixing C.P. Angular stop clock with wall flange Jaquar make or equivalentcontinental (CAT.NO. CON-059) including necessary sockets/union nut etc. complete. 33 Providing and fixing C.P. pillar cock long neck with aerator jaquar or equivalent make continental (CAT.NO. CON -021) including necessary sockets/union nut etc. complete. 34 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 35 Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 36 Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. 37 Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets & necessary fittings and tested as per municipal requirement etc. complete. 38 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres 39 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 40 Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover. 41 Providing & constructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover etc. complete. 42 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange jaquar or equivalent ?make continental (CAT.NO. CON-273 UPR) including necessary sockets/union nut etc. complete. 43 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 44 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. 45 Providing and fixing crimped with G.I. mesh and size 20 mm x 20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel) 46 Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. 5 km leadloading unloading 47 Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. 48 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 kg) 49 Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 kg) 50 Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kg/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaningetc. complete. (using 100% crushed sand) 51 Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards,screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. 52 Providing and fixing Shutter to wall Cupboard consisting of Teak Wood styles and Rails 25 mm thick and 75 mm wide with panel insert of 12 mm thick particle Board with one approved coloured Laminated Face on one side 1.5 mm thick, bonded with Phenol Formaldehyde Synthetic Resin including Lipping Beading. Iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame). 53 Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 90 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete.(excluding painting to underside of plank). 54 Providing and fixing C.P. 2 Way BIB cock with wall flange of approvedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge. 55 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) 56 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete 57 Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. 58 Trimming of grass, shurbs and weeds from the shoulders/berms and disposing off the same to suitable locations etc. complete 59 Replacement of damaged Mortise Lock of approved quality and make to door shutter including Removing and Refixing with Necessaryscrew, making proper adjustment for smoothoperation etc. complete as per sample approved by Engineer in-chareg. 60 ProvidingHydrulic door closer .... 61 ProvidingSuper Jet Spry with flange 2 in 1 faucet 1.50 mtr long. 62 Providing Skilled plumber with tools as per direction of Engineer Incharge. 63 Providing skilled carpentor with tools as per direction of Engineer Incharge 64 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface and including scraping etc. complete. 65 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 66 Providing and applying single coats ofexterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. 67 Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete 68 Providing and fixing high level 10 liter capacity with fittings inlet PVC pipe with stop tap ,brackets for fixing the cistern,32 mm dia. PVC flush pipe with fitting and clamps 20 mm dia. PVC overflow pipe with mosquito proof couplings, galvanised iron chain and pulley painting if ordered to cistern pipe etc. and cutting and making good the damaged wall and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) 69 Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. 70 Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete 71 Providing curtain rod dropping with channel MAC brand of superiar quaility including all required material labour etc complete. as directed by engineer incharge......... 72 Replacement of damaged alluminium Butt Hinges of 125 mm of approved quality and maketo door shutter including removing existing the same inoriginal position making prope radjustment for smooth operation etc. complete as per sample approved by Engineer incharge. 73 Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and maketo door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. 74 Replacement of damaged Tower Bolt 300 mm Chromium plated of approved quality and maketo door/window shutter including removing existing the same inoriginal position making proper adjustment for smooth operationetc.complete as per sample approved by Engineer in-charge. 75 ProvidingHandle 150 mm Chromium plated (Rounded shape). 76 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. 77 Providing and injecting epoxy grout including structuring of crack in the body of slab girder by sand blasting, fixing inlet tube arrangement including cost of materials, machinery required for the work and labour charges etc. complete. 78 Providing & fixing Decorative wall paper superior quality including adhesive to fix at wall etc complete. as directed by engineer incharge......... 79 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 80 Providing & fixing Mica laminate as per ISI 0.1 mm thick etc complete...... 81 Providing & fixing 19 mm plywood 710 bwp full red core with report etc complete...... 82 Providing & fixing 12 mm plywood 710 bwp full red core with report etc complete...... 83 Providing & fixing teak wood batterns 50x25 mm etc complete...... 84 Providing & fixing plain glass 6 mmetc complete...... 85 Providing & fixing teak wood batterns 70x45 mm etc complete...... 86 Providing & fixing door stopper etc complete...... 87 Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete. 88 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 89 Providing and Laying wearing laminate wooden or eqiuvalent flooring 8 mm thick in attractive strips for conference hall. 90 Providing, laying andfixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 kg/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 91 Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. 92 Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with allnecessaryfixturesandfittingetc.complete.(SampletobefinalbyEngineerIn-charge prior execution of work) 93 Providing and applying French polish for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding etc. complete as directed 94 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. 95 Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 96 Providing and fixing C.P. sink cock with raised J shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete. 97 Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. 98 Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. 99 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 100 BASIC TEST OF CEMENT :-Standerd Consistancy Fineness, Specific Graviti, Setting Time (Initial & final, Compressive Strength, Soundness. 101 BASIC TEST OF BRICK :-Water Absorption, (Set of 5 Brick), Comoressive Strength (Set of 5 Blocks), Efflorescence (Set of 5 Bricks) 102 CERAMIC TILES/ VITRIFIED TILES :- Water Absorption, Modules of Rapture (Set of 6 Tiles) 103 BASIC TEST OF C. C. TILES. :-Flexural test(Set of 6 tiles) Water Absorption,(Set of 6 tiles) Resistance to wear(Set of 6 tiles). 104 BASIC TEST OF Fine Aggregate Fineness Modulus (Sieve Analysis) silt and cley content..... 105 BASIC TEST OF Concrete Paving Block :- Compressive strength, Water Absorption, (Set of 8 Blocks ) 106 BASIC TEST OF STONE / RUBBLE/ Crushing Value/Compressive strengh, Water 107 Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction materials for whichroyalty is necessary.(Royalty charges will be paid to contractor after sumbitting valid documents of revenue authority)Royalty for naturalSand (Royalty + Surcharges 2% & Distt. mineral foundation cess 10%)
Contract Date: Jun 04, 2026 Contract Value : 15.18 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
12.
Defence #11219952 AOC
Tender For (Schedule-A Part-I B/R Works) Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Not Exc 1.50 Sqm Each And Removing From Site Complete All As Specified And Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Exc 1.50 Sqm Eachand N Exc 4 Sqm And Removing From Site Complete All As Specified And Directed. , Taking Down Shutter Of Any Description Area Exc. 1 Sqm And N.Exc. 2 Sqm And Removing From Site Complete All As Specified And Directed. , Demolition Of Brick Work Built In Cement Mortar Including All Quions, Arches, Pillars Etc But Excluding Ashlar Facings Dressed Stone Work And Precast Concrete Articles Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) Of Any Description And Any Position Not Other Wise Specifically Provided Complete All As Specified And Directed. , Demolition Of Cement Concrete (Reinforced) Of Any Description And Any Position Not Other Wise Specifically Provided Reinforcement Cut As Required To Facilitate Demoltion Complete All As Specified And Directed. , Taking Down Cement Plaster On Brick Or Stone Wall Etc Including Racking Out Joints, Hacking For Key Scrubbing Down With Water Etc To Receive New Plaster Etc. Complete All As Specified And Directed. , S&F Pressed Steel Frames Of Size 125 Mm X 60 Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc. Complete All As Specified And Directed. , S&F Pressed Steel Frames Of Size 105 Mm X 60 Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc Complete All As Specified And Directed. , S & F For 35 Mm Thick Factory Made, 2Nd Class Hard Wood Glazed And Skeleton Shutters Open Rebeated And Prepared To Received Glass, Gauzed, With Out Sash Bar Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitered Beads For Securing Glass Etc, Size Of Member Of Shutter As Per Specified In Ssr Part-I Section 8, Clause 8.24 (A) And For Door And Fixed With Chowkats, Chemically Pressure Treated Complete All As Specified And As Directed. , S&F For 35Mm Thick 2Nd Class Hard Wood Plain, Framed Pannelled Shutters (Two Panel) With Lock Rail And Panel Of 9Mm Bwp Commercial Ply Or 12Mm Veneered Particle Board Wiyh Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per (Is : 1003 Part-I , Kiln Seasoned And Chemically Pressure Treated Complete All As Specified And As Directed. , S&F Box Type Steel Window Side Hung Double Shutters With Provision For Desert Cooler/Ac(Inside For Wire Mesh & Out Side For Glass), Including Guard Bar,Hinges, Steel Handle, Tower Bolt And Steel Peg Stay Complete With Glazing Bar Dovetailed Or Welded And Fixed, Steel Window Shall Be Conforming To Relevant Is Complete All As Shown On Drawing No Ceuz/Td/1302/09, Sh 1/3 To 3/3 And Directed. Complete All As Specified And Directed. Note:- Wire Mesh And Sheet Glass Shall Be Measured And Paid Separately , S&F Steel Ventilators Top Hung Double Shutters (Inside For Wire Mesh & Out Side For Glass), Including Hinges, Steel Handle, Tower Bolt And Steel Peg Stay Complete With Glazing Bar Dovetailed Or Welded Including A Coat Of Red Oxide After Preparation Of Surface Before Fixing.Steel Window Shall Be Conforming To Relevant Is All As Specified. Note:- Wire Mesh And Sheet Glass Shall Be Measured And Paid Separately , S&F For Sheet Glass Palin/Coloured (As Per Directed By Engr-In-Charge) 3Mm / 5 Mm Thick Best Quality And Glazing With Rubber Packing, Screws Or Glass Putty In Squares Exc 0.5 Sqm Each Pane Complete All As Specified And Directed. , S & F For Stainless Steel Wire Cloth Of 0.36Mm Dia Wire And Average Width Of Aperture 1.40Mm & Fixed With Tacks Or Screws, Wire Staples, Etc Complete All As Specified And Directed. , S&F Factory Made Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Wooden Grain Printed Pvc Sheet & Edges Will Be Painted To Match With Printed Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawingreinforced Complete All As Specified And Directed. , S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of Ms Tubes For Top & Bottom Rails. Ms Frame Shall Be Covered With Heat Moulded Wood Grain Printed Pvc Sheet 5Mm Thick X15Mm Wide Pvc Sheet Beading Used Inside Stiles And Rails And Decorative Pvc Beading Of 10Mm X 10Mm (900 ) Used Instead Of Exposed Portion Of Pvc Sheet Beading Pvc ‘C Channel Having A Pvc Sheet Strip Of 20 Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail. Panelling Of Plain Colour Pvc Sheet To Be Fitted In The Ms Frame Welded/Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Complete All As Specified And Directed. , S&F 100 Mm Long Mild Steel Butt Hinges, Cold Rolled, Medium Weight Complete All As Specified And Directed. , S&F For 125Mm Long Anodised Aluminium Barrel Tower Bolt Of Extruded Section Complete All As Specified And Directed. , S&F 150Mm Long Anodised Aluminium Handles, Cast Type Complete All As Specified And Directed. , S & F In 300Mm Long Aluminium Alloy, Anodized Sliding Door Bolt With Hasp Stapple ( Bolt Type) And Fixing Clips Of Sheet Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminium Alloy And Fixed Complete All As Specified And Directed. , S&F For 20 To 25 Mm Dia Stainless Steel Drapery Curtain Rod With Brass /Nickel Chrom Polish / Designer Lattos And Brackets Complete All As Specified And Approved By Engr-In-Charge Including Taking Out Old Pelmet With Curtain Rods Complete All As Specified And Directed. , S&F 300 Mm Long Mild Steel Ordinary Rat Tail Rod Pattern Spring Including Roller And Roller Plate Complete All As Specified And Directed. , S& F Floor Door Stopper Of Aluminium Alloy Body And Tongue ,Anodised ,With Hard Drawn Steel Spring ,Fixed In Floor Overall Length Of Cover Plate 140Mm Complete All As Specified And Directed. , S & F 2 Nd Class Hardwood For Plain, Solid, Straight Chowkats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue Pinned At Joints, Complete All As Specified And As Directed. , S & F For Pvc And Cupboard Shelf/ Partition/ Frame / Shutter Of 18Mm Thick Side Of Panel Externally Impact Perfact Finish To The Shutter And Joined Together With Solvent Cement Adhesive 8Mm Thick (4Mmx2)X12Mm Wide Pvc Sheet Is Used As Gap Insert For Top & Bottom Rail, 18Mm X 1Mm Pvc Edge Lipping Is Done On Top & Bottom Side Using Pvc Solvent Cement Adhesive, Incl Hasp And Stable For Locking Purpose, Etc Complete As Per Direction Of Engr-In-Charge, Manufactures Specification And Drawing. , M&L For Block Boards 18/19 Mm Thick, Grade 2 Quality, I N T E R I O R Grade, Decorative Type With Decorative Face Veneer On One Face, Fixed With Screws To Timber Frame-Work For Partision Of Cupboard Complete All As Specified And Directed. , M&L For Brick Work With Sub Class B Bricks Straight Or Curved On Plan Exc. 6M Mean Radius Built In Cement Mortor 1:6., Etc Complete All As Specified And Directed. , M&L For Rendering 10Mm Thick In Cm 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. , M&L For Rendering 15Mm Thick In Cm 1:4 On Other Than Fair Faces Of Brick Or Concrete Surface With Liquid Water Proofing Compound @ 200 Ml Per Bag Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed.(Note:- Liquid Water Proofing Compound To Be Measured Paid Separately) , M&L For Rendering 5Mm Thick In Ceiling Cm 1:3 On Fair Faces Of Brick Work Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. , Supply Only Liquid Water Proofing Compound Complete All As Spesified And Directed. , M&L Plain Cement Concrete 1:4:8, Type D2( Using 40Mm Graded Stone Aggregate) 75Mm Thick As In Sub Base Of Floor/ Interlocking Paver Block Complete All As Specified And Directed . , M & L 25Mm Thick Cement Concrete Type B-0, 1:2:4 (Using 12.5 Mm Graded Aggregate) For Levelling Course In Floors Complete All As Specified And Directed. , M & L For Non Skid Joint Free Coloured Ceramic Floor Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exc 0.11 Sqm But N Exc 0.18 Sqm,In Floor Etc Set & Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface With 15Mm Thick Screed Bed Or Bedding Layer In Cm (1:6) Complete All As Specified And Directed. , All As Per Item No 35 Above But As In Skirting/ Dado Etc With And Including 10Mm Thik Backing Coat In Cement Mortar 1:4 An Wall Complete All As Specified And Directed. , M&L For Glazed Ceramic Coloured Wall Tiles (Textured And Design As Required) In Vertical Surface 450X300X7Mm Thick, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 10 Mm Thick Rendering In 1:4 Cm Complete All As Specified And Directed. , M & L For Applying Two Coat Of Synthetic Enamel Paint On New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. , M & L For Applying Two Coat Of Synthetic Enamel Paint On Old Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. , M & L For Preparing New Plastered Surfaces Of Wall And Applying Two Coats Of Distemper Oil Emulsion Over A Coat Of Alkali Resistant Cement Primer And Over A Coat Of Putty Complete All As Specified And Directed. , Material And Labour For Apply Two Coats Of 100% Premium Anti Fungal Weather Coat Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistence As Per Is 15489;2004, Alkali & Fungal Resistence, Dirt Resistence Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.9 Litre / 10 Sqm Over New Surfaces Complete All As Specified And Directed. . Note:- (A) Each Stage I.E. Preparation Of Surfaces, Application Of Primer, Application Of First Coat, Application Of Second Coat Will Be Got Passed From Engr-In -Charge.The Acrylic Emulsion Paint Work Shall Be Carried Out By Using Smart Painting Tools And Techniques As Specified In Particular Specifications And Contractor Will Have To Produce Necessary Documents For Purchase Of Smart Painting Tools Or Rent Receipt Of These Tools Along With Bill/Rar.The Bidders Are Requested Take This Aspect In Consideration Before Quoting Their Rate And No Clain On Account Of Misunderstanding Or Otherwise Shall Be Admissible On This Account. , M & L For Preparing New Plastered Surface On Ceiling And Applying Three Coat Of White Wash Complete All As Specified And Directed. , M&L For Complete Removal Of Exsting Treatment On Plastered Or Unplastered Surface Including Removal By Brooming Down With Steel Wire Brushing, Scraping Down Smoke Soot, Moulded, Moss, Efflorscent Salt, Trading Oil And Greasy Spots And Applying Two Coat Of Oil Bound Distemper On Walls Over A Coat Of Putty Complete All As Specified And Directed. , Material And Labour For Complete Removal Of Existing Treatment And Apply Two Coats Of 100% Premium Anti Fungal Weather Coat Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistence As Per Is 15489;2004, Alkali & Fungal Resistence, Dirt Resistence Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.9 Litre / 10 Sqm On Old Surfaces Complete All As Specified And Directed. Note:- (A) Each Stage I.E. Preparation Of Surfaces, Application Of Primer, Application Of First Coat, Application Of Second Coat Will Be Got Passed From Engr-In -Charge.The Acrylic Emulsion Paint Work Shall Be Carried Out By Using Smart Painting Tools And Techniques As Specified In Particular Specifications And Contractor Will Have To Produce Necessary Documents For Purchase Of Smart Painting Tools Or Rent Receipt Of These Tools Along With Bill/Rar.The Bidders Are Requested Take This Aspect In Consideration Before Quoting Their Rate And No Clain On Account Of Misunderstanding Or Otherwise Shall Be Admissible On This Account. , M&L For Three Coat Of White Wash On Old Surface On Wall Including Preparation Of Old Surface Complete All As Specified And Directed. , M&L For Three Coat Of White Wash On Old Surface On Ceiling Including Preparation Of Surface Complete All As Specified And Directed. , Dismantling Of Kota Stone Slabs And Tiles Of Any Description Or Thickness In Laid Bedded And Pointed Floors, Aprons Etc Incl Screed Bed Complete All As Specified And Directed.. , M&L For Machine Cut Kota Stone Slab Flooring 18-20 Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completeand Including 20 Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And As Directed. , M&L For Kota Stone Slab 18-20 Mm Thickin Riser Of Steps, Skirting, Dado And Pillar Laid Over Cement Screed And Jointedwith Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completeand Including 10 Mm Thick Rendering In Cm 1:4 Complete All As Specified And As Directed. , M&L For Rubbing And Washing Of Kota Stone Floor And Mirror Polishing On Kota Stone/ Stone Work Where Ever Required To Give High Gloss Finish Complete All As Specified And Directed. , M & L 20Mm Thick Granite (Of Any Type) Work (Table Rubbed And Polished) In Steps, Jambs, Pillars, Window-Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite With Providing 15Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And As Directed.. , M&L Plain Cement Concrete 1:3:6, Type B1( Using 20Mm Graded Stone Aggregate) 75Mm Thick As In Plinth Protection Complete All As Specified And Directed . , Demolition Of Cement Or Lime Concrete In Any Despription Along With Tarfelt Treatment In Sunken Portion / Roof And Cement Mortar Bedding From Roof Removal Rubbish Out Side Md Land Complete All As Specified And Directed. , M&L For Plain Cement Concrete 1:2:4 Type B-0 Using 12.5Mm Graded Crushed Stone Aggregate As In Sunken Portion, Subbase, Etc Complete All As Specified And As Directed. , M&L For Water Proofing Treatment To Sunken Portition / Roof Etc. In Following Sequence:- (I) Properly Cleaning And Drying The Surface (Ii) Applying A Coat Of Bitumen Primer @ 1.2Kg/Sqm And Primer Shall Be Allowed To Dry Over Night. (Iii) Laying App Based Modified Water Proofing Membrane Of Weight Not Less Than 3Kg Per Sqm And Thickness Not Less Than 3 Mm, With 100Mm Overlaps, Sealed And Bonded To The Surface By Torchon Method (Iv) Applying Two Coat Of Bituminous Based Aluminum Painting @ 0.15 Kg/Sqm Each Coat On Water Proofing Treatment With Preparation Of Surfaces Complete All As Specified And Directed At Site. , S&F Vitreous China Squatting Pan Orissa Pattern Of Size 580X440Mm White With Integral Foot Rest (Excluding Flushing Cistern And Flush Pipes) Including Connection To Trap And To Flush Pipe Etc And Lime Concrete Bedding Including P Or S Trap Complete All As Specified And Directed. , M & L For Complete Removal Of Existing Sunken Treatment And Clean The Surface Of Sunken Slab , Appling Plain Cement Concrete B1 1:2:4 (20 Mm Aggregate Of ) With Wpc Of Thickness 100 Mm Finished Even And Fair With 1:20 Sloped Towards Corner Of Outer Wall & Pvc Pipe Of Require Dia Be Inserted At Corner Projecting Outside 20 Cm From Wall And 15 Mm Plaster Cm 1:3 With Wpc Is Also Applied Over Plain Cement Concrete And Returning Filling The Sunken Slab Complete All As Specified And Directed , M&L In Repairs Pvc Valve Less,Syphonic Action Type Flushing Cistern,Low Level ,White With Inlet Ball Valve,Float And Handle Including Brackets And Connection To Pipe And Fixing Of Chain And Pull Or Lever If Any Complete All As Specified And Directed. , Supply And Fixing Of Soap-Dish Chromium Plated Complete All As Specified And As Directed. , S&F In Repairs Of Brass Cp Tubular Towel Rail 20 Mm Dia 60Cm Long Between Flange With Brackets Etc As In Repair Complete All As Specified And Directed. , S&F Vitreous China Wash And Basin, White, Flat Back, Size 550 Mm X 400 Mm Incl Fixed On New Ms Bracket, Fixing Of Tap, Waste Coupling,Fitting,Waste Pipe And Union Incl 15 Mm Bore Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed Complete All As Specified And Directed. , S & F Pvc (Swr) Nani Trap / Floor Trap Plain Or Multi With Stainless Steel Grating Incl Joining To Waste Pipe With Solvent Cement Joint Dia Of Outlet 75Mm Bore Complete All As Specified And As Directed. , S&F In Repair 110Mm Bore Pvc (Swr) Bends Any Radius Complete All As Specified And As Directed. , S&F In Repair 75Mm Bore Pvc (Swr) Bends Any Radius Complete All As Specified And As Directed. , S & F In Repair 110 Mm Bore Pvc (Swr), Junction Single, (Single T) Equal Or Unequal Complete All As Specified And Directed. , S & F In Repair 75 Mm Bore Pvc (Swr), Junction Single, (Single T) Equal Or Unequal Complete All As Specified And Directed. , S & F In Repairs 110Mm Bore Pvc (Swr) Pipes Singles Socket In Any Length With Rubber Ring Joints Fixed To Walls / Floor Or In Tren1Ches Complete All As Specified And As Directed. , S & F In Repairs 75Mm Bore Pvc (Swr) Pipes Singles Socket In Any Length With Rubber Ring Joints Fixed To Walls / Floor Or In Trenches Complete All As Specified And As Directed. , M & L For Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Not Exc 10Cm Girth Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Dia Old Serviceable / Unserviceable Steel Tubing Any Grade And Connections Cleaning For Re-Fixing Or Removal To Store Complete All As Specified And Directed . , All As Per Item No 70 Above But 20Mm Bore Complete All As Specified And As Directed. , S&F Steel Tubing Medium Grade ,Galvanized With All Fitting Such As Bend ,Elbow, Socket,Tees,And Fixed Complete To Wall Or In Ceiling Or In Floors Including Cutting Threading And Making Forged Bends On Pipes Ms Hooks Etc ,For 15Mm Bore Pipes Complete All As Specified And As Directed. , All As Per Item No 72 Above But 20Mm Bore Complete All As Specified And As Directed. , S&F In Repair For 15Mm Bore Bib Taps Chromium Plated With Crutch Or Butterfly Handle ,Screwed Down , Screwed For Iron Pipes Or Brass Ferrule Complete All As Specified And Directed. , S&F In Repair Cp Angle Stop Cock Of 15Mm Bore Screwed Down For High Pressure With Crutch Or Butter Fly Handle ,Screwed Both End For Iron Pipes Complete All As Specified And Directed.. , S&F In Repair Cp Wall Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe 15Mm Bore Complete All As Specified And As Directed. , S&Fixed In Repair 125 Mm Size Chromium Plated Shower Rose With Siwel Joint Suitable For 15 Mm Bore Gi Pipes Complete All As Specified And As Directed. , S&F In Repairs Pvc Connection 15Mm Size With Ptmt Nuts Of Length 450 Mm Long Complete All As Specified And As Directed. , S& F In Repair Rotational Moulded Polyethylene Water Storage Tank 500 Liters Capacity (Cylidrical Vertical With Closed Top) Hoisted And Fixed In Position All As Specified In Ssr Part I Incl Brass Float Valve 20Mm Dia And Dismantling Water Tank. , S & F In Shelf Of Ptmt Fixed With And Including Chromium Plated Brass Screws And Wooden/Plastic Cleats (Minimum Weight 300 Grams) Complete All As Specified And As Directed. , S&F In Trepair Kitchen Sink With Drainage Board Made Of Stainless Steel 1.0 Mm Thick In Kitchen With Plug , Washer And Waste Including Bedding Layer In Cm (1:6) In Wall Or Including Fixing Cantilever Bracket And Connecting Union To Pipes Over All Size 915X460 Mm Bowl Size 410X330X160 Mm Including Taking Out Unserviceable Kitchen Sink Complete All As Specified And As Directed. , M&L For Stain Less Steel Plate Rack For Kitchen 1 Mm Thick Of Best Quality With Suitable Hanging Arrangement And Fixed To Wall Complete All As Specified And Directed .Note:- Size Of Plate Rack Should Not Be Less Than 900X1200 Mm And Weight Of Rack Shall Not Be Less Than 8.5 Kg Each Complete All As Specified And As Directed. , S&F In Repair Gun-Metal, Globe Or Gate Valves, 20 Mm Dia Bore Pipes With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed Complete All As Specified And As Directed. , M & L High Strength Steel Deformed Tmt Bars 10 Mm Dia And Over, Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping Columns,Hookings Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.90 Mm Dia Or Securing With Clips, Etc Complete All As Specified And Directed. , M & L For Formwork Fair And Finished Surfaces To Sides And Soffits Of Floor Or Roof Beam, Beam Hauchings, Bands, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc Complete All As Specified And Directed , M&L Reinforced Cement Concrete B1 1:2:4 Using 20 Mm Graded Stone Aggr As Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Etc Complete All As Specified And Directed , M & L For Formwork Flat Fair Finished Surfaces To Sides And Soffits Of Floor Or Roof Beam, Beam Hauchings, Bands, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc Complete All As Specified And Directed , M&L Reinforced Cement Concrete M-25 Using 20 Mm Graded Stone Aggr As In Beams, Bands, Cantilvers, Bressummers, Linters, Chajjas, Etc Over 1.5M Span Etc Complete All As Specified And Directed , M&L For Mild Steel Bars (Tmt Bars) 5Mm Dia And Over Upto And Including 10Mm Dia In Strriups,Spacers And Binders Complete All As Specified And Directed. , M & L For Precast Cement Concrete 1:2:4 Type B-1 (Using 20Mm Graded Crushed Stone Aggregate) As In Manhole/Drain Slab Cover All As Specified And Set In Cm 1:4 Complete All As Specified And Directed. , Excavation In Trenches N.Exc 1.5M Wide And N.Exc 1.5M In Depth For Foundation Or Etc, For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc N.Exc 10 Sqm On Plan And N.Exc 1.5M In Depth And Getting Out In Hard Dence Soil, Complete All As Specified And Directed. , Returing, Filling In Trenches, Incl Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm In Hard/Dense Soil Complete All As Specified And Directed. , Removing Excavated Material (Soil) To A Distance Not. Exc. 50 Mtr And Depositing Where Directed At A Level Nexc 1.5 Mtr Above The Starting Point Complete All As Specified And Directed. , Demolition And Breaking Up 150Mm Dia Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete ) And Set In Cement Mortar Complete All As Specified And Directed. , M&L For Concrete Bed To Drain Pipes Including Packing Under, And Haunching Against The Sides Of 150 Mm Bore Pipes In Cement Concrete 1:3:6 Type C-2 ( Using 40 Mm Graded Stone Aggregate) After They Are Laid And Tested Complete All As Specified And Directed. , M&L For 150 Mm Bore Salt Glazed Stone Were (Sgsw) Drain Pipe Grade A Laid To Slope In Tranches And Jointed In Cement Mortar (1:1) Including Necessary Testing For Ensuring Teak Proofing Complete All As Specified And Directed. , M & L For Cutting Into Existing Manhole For Connecting New Drains And Making Good To Pipes And Rendering Cutting Out Existing Benching For And Forming Branching For And Forming Branch Channel (1/2 Round Or ¼ Section ) In Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Crushed Stone Aggregate Smooth Finished And Reforming Benching As Specified And Directed For 150Mm Dia Of Pipe Complete All As Specified. , M&L For 60Mm Thick Machine Pressed Precast Concrete Interlocking Paver Block (Glossy Finish) Of M-35 Gde Of Approved Shape, Size And Colour Conferming To Is 15658-2006 And Laid Over And Including 25Mm Thick Grid/Sand Cushion Complete All As Specified And Directed. , S & F For Precast Cement Concrete Type B-1 (1:2:4) (20 Mm Graded Stone Aggregate) As In Kerb And Edging To Road And Footpath Etc, Including Chamfered, Weathering, Throating, Etc Setting In Cm(1:4) Complete All As Specified And Directed. , S & F In Repairs Ms Framed Work As In Doors Or Gates Of Angle Iron, Door Frame Or Other Section With Gusset Plate, Rails, Braces And Stair Case Etc Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering Etc, To Prepared For Hanging Or Sliding With Including Either Hooks And Hinges Also Fastening Grills, Grating, Hold Fast Of Doors And Windows Chowkat Etc, With Ends Of Bars Shouldered And Or Riveted, Or Forget Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walkways; Railings; Framework Of Water Tanksand Fixing And Similar Work Confirming To Fe 290 Gde E-165 Complete All As Specified And As Directed. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing), And Rubbish Off The Premises Complete All As Specified And Directed. , M&L For Cement Concrete B1 1:2:4 (20Mm Aggregate) In Foundations, Filling And Mass Concrete Complete All As Specified And Directed. , M & L Cement Concrete Type B1 1:2:4 ( 20 Mm Graded Aggregate) As In Coping, Bearing Course, Manhole/ Drain Channels Etc In Including Necessary Formwork Complete All As Specified And Directed. , M&L For Preparation Of New Steel Surfaces Exc 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified And Directed. , S&F 600Mmx450Mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers, Complete All As Specified And Directed. , M&L For Preparation Of Old Steel Surfaces Exc 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified And Directed. , (Schedule-A Part-Ii E/M Works) Taking Down Carefully Unserviceable Aluminium Point Wiring Complete (Light, Fan Socket, Bell Or Power) With Fitting Such As Switches, Ceiling Rose Lamp Holder, Regulators, Sockets, Light Fittings Etc. And Keeping In Safe Custedy For Taking Credit Complete All As Specified And As Directed. , (Schedule-A Part-Ii E/M Works) Taking Down Carefully Unserviceable Aluminium Point Wiring Complete (Light, Fan Socket, Bell Or Power) With Fitting Such As Switches, Ceiling Rose Lamp Holder, Regulators, Sockets, Light Fittings Etc. And Keeping In Safe Custedy For Taking Credit Complete All As Specified And As Directed.
Contract Date: Jun 15, 2026 Contract Value : 31.73 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Jammu and Kashmir View Result →
13.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
14.
Defence #11198549 AOC
Tender For Spl Repair To Certain Md Accn In Kandhar Line Under Ge Central Delhi Cantt-10; 1 Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubbing down with water etc including remove alldebris at 2 KM away from site complete all as specified and directed. 2 M&L for 15 mm thick rendering in cement mortaron fair faces of brick work or concrete surfaces, applied in two layers i.e. 1st layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd (top) layer of 5 mm thick rendering in cement mortar (1:4 )mixed with WPCfinished even and fair etc complete all as specified and directed.(Note:- WPC shall be measured and paid separately) 3 M&L for rendering 10 mm thickin CM 1:6 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed. 4 M&L for rendering 5 mm thick in CM 1:3 on ceiling concrete surfaces finished even and fair without using extra cement complete all as specified and directed. 5 M&L for preparation of new plaster surfaces of wall and applying water proof wall putty 1-2 mm thickness over plastered surfaces to prepare the surfaces even and smooth and finishing walls with Two coats @ 1.67 ltr/10 Sqm each acrylic smooth exterior paint of required shadeover and including priming coat of exterior primer @ 2.20 Kg/10Sqm complete all as specified and directed. 6 M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper complete all as specified and directed. 7 M&L for Preparation of new surfaces (Plastered or un-plastered) of ceiling and applying two coats of oil bound distemper complete all as specified and directed. 8 M&L for complete removal of existing treatment of old decorated plastered or unplastered surfaces of wall by rubbing , brooming down, washing with water etc and applying two coats of oil bond distemper complete all a specified and directed. 9 M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing tretament, by rubbing brooming down, washing with water etc and providing and applying 1-2 mm thickness wall putty over plastered surfaces to prepare the surface even and smooth and finishing wall surfaces by applying Two coats @ 1.67 ltr/10 Sqm each with acrylic smooth exterior paint of required shade over and including priming coat of exterior primer @ 2.20 Kg /10Sqm complete all as specified and directed. 10 M&L for dismantling water tanks of capacity exc 250 litres & n. exc 500 litres complete all as specified and directed. 11 M&L for rotational moulded polyethylene water storage tanks (ISI Marked) white colour 500 litres capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT float valve, lid tank cover for polyethylene and polyethylene ball complete all as specified and directed. 12 S&F 15 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed 13 S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed 14 Demolition Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (each layer) complete all as specified and directed. 15 Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thickness removed or only a part thereof) complete all as specified and directed. 16 Removing soil excavated material exc. 1.5Km but n exc 5km and depositing where directed at above the starting pointcomplete all as specified and directed. 17 M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone crushed aggregates) on roof padding, surface finished even and smooth without using extra cement complete all as specified and directed. 18 M&L for providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer or equivalent (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalentcomplete all as specified and as per manufacturers instructions. 19 M&L for providing and applying Smartcare Dampproof or equivalent, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per manufacturers instructions and all as specified & directed. 20 Supply only integral water proofing compound (ISI marked) complete all as specified and directed 21 Demolition of brick work built in cement orcement lime mortar of any description including quoins,arches,pillars,etc., complete all as specified and directed 22 M & L for brick work with Cement Mortar 1:6 using sub class B bricks, old size, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed. 23 All As per item no 22 before but except bricks etc complete all as specified & directed 24 Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 complete all as specified and directed. 25 Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed 26 Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed 27 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified & directed. (M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 28 S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified & directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 29 S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 65 x 125 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (max toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr incharge. Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made. 30 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 31 S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately).Note: MTC and Screw Out Test shall be provided by Contractor 32 Supply and fixing 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of density 650 kg/cbm manufactured by an ISO-9001-2015 certified company. Door to be panelled with SS mosquito and XTN aluminium mesh for additional strength and safety purpose (confirming as per IS 4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. SS butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through other hardwares should be fixed with 19x6mm size steel screws, etc. complete all as specified& directed.”Note: MTC and Screw Out Test shall be provided by Contractor 33 S&F Aluminium windowfor outer frame 40mmx114mm with 1.3mm thickness ,corner 45 degree cut & aluminum welded center mullion size 40mmx65mm also welded, shutter(02) size 40mmx60mm 1.3 thickness 45degree cut mechanically joint with 6mm alen key bolt clamp , 12mm SS 202 grade round bar at 100mm cc distance in middle 150mm cc distance for safety grill welded at both ends with 6mm ss 202 grade round bar, 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock , aluminum kobra hinges 2 nos per shutter , 40x18mm 45 degree cut & welded mosquito net shutter(02) with 0.45mm nominal dia of SS wire mesh,SS 75mm long hinges & pvc magnet,full system powder coating with pure polyster coat of any shade as approved by GE and installing with SS screw roll plug and filled with silcone complete all as specified and directed. 34 S&F Aluminium windowOuter frame 40mmx114mm with 1.3mm thickness ,corner 45 degree cut & aluminum welded center mullion size 40mmx65mm also welded, shutter (02) size 40mmx60mm 1.3 thickness 45degree cut mechanically joint with 6mm alen key bolt clamp , 12mm SS 202 grade round bar at 100mm cc distance in middle 150mm cc distance for safety grill welded at both ends with 6mm SS 202 grade round bar, 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock , aluminum kobra hinges 2 nos per shutter , 40x18mm 45 degree cut & welded mosquito net shutter(02) with 0.45mm nominal dia of SS wire mesh,SS 75mm long hinges & pvc magnet,full system powder coating with pure polyster coat of any shade as approved by GE and installing with SS screw roll plug and filled with silcone complete all as specified and directed. NOTE:- For installation of windows AC/desert cooler the provn of window glass shutter with wire mesh,grill and necessary fittings and locking arrangement for subject portion will be modified as per ground requirementt during execution as direction of Engg-in-Charge. 35 S&F ventilator outer frame 40mmx40mm with 1.3mm thickness, corner 45 degre cut & aluminum welded center mullion size 40mmx65mm also welded , fixed 5mm frosted glass EPDM rubber gasket with provision for fresh air fan, full system powder coating with pure polister coat of any shade install with SS screw rol plug pvc & silicone complete all as specified & directed 36 Dismantling of wall and ceiling/cupboard board fibre pulp AC boards etc any thickness including cover fillets removing the wiring complete all as specified & directed 37 S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbmhaving good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws complete all as specified & directed. Material test certificate and authentication should be compulsory provided by the contractor. (For WC/Bathroom/Toilet/Kitchen and Cabinets) 38 S&F stainless steel continuous (Piano) hinges, bright finish, width of flap when open 30mm, complete all as specified & directed. 39 S&F of stainless steel handles 100 mm sizefor kitchen cabinet shutters and bed room cub boards complete all as per specified and directed. 40 S&F brass chromium plated tubular hanger rod 20 mm dia with suitable brackets complete all as specified and directed. 41 S&F for PVC magnetic door catches of kitchen cabinet and similar work fixed with MS screws complete all as specified & directed 42 S&F SS butt hinges medium weight 100mm size fixed with SS screws (ISI Marked) complete all as specified & directed 43 S&F SS barrel tower bolt extruded section 150mm long and fixed with SS Screws (ISI Marked) complete all as specified & directed 44 S&F 150mm extruded SS handle fabricated type and fixed with SS Screws(ISI Marked) complete all as specified & directed 45 S&F 300mm extruded section SS sliding door bolt with hasp and staple and fixing bolt and nut (ISI Marked) complete all as specified & directed 46 S&F for 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar complete all as specified & directed. 47 M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed 48 M&L for preparation of Old or previously treated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified & directed. 49 S&F for stainless steel plate rack of size 90x80x25 cm depth size made out of 1mm thick sheet complerte all as specified and directed. 50 S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet for kitchen with plug, washers, waste pipe, waste coupling incl fixing cast iron cantilever bracket connecting union over all size 915x460mm with bowl size410x330x160mm complete all as specified and directed. 51 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm etc complete all as specified & directed 52 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm etc complete all as specified & directed 53 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 40mm etc complete all as specified & directed 54 Supplying and laying 16 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete all as specified and directed 55 All as per item No. 54here in beforebut 20 mm dia complete all as specified and directed. 56 All as per item No. 54 here in beforebut 40 mm dia complete all as specified and directed. 57 S & F Floor door stopper 150mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed 58 Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for concealed water tubing etc cutting exceeding 10cm girth but not exc. 20 cm complete all as specified & directed. 59 Supply and fix in repairvitreous China wash hand basin (including pedestal)white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper and waste pipe & waste coupling including all necessary fitting and fixtures complete all as specified & directed 60 Supply and fix in repairs vitreous china squatting pan Orissa pattern long pan size 580x440mm white with integral foot rests ‘standard Grade P’ or ‘S’ trap front or back inlet (excluding flushing cistern and flush pipe) complete all as specified and directed, 61 S&F in repair vitreous china wash down water closet EWC white/ ivory/off white (closedpattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flushpipe) complete in all respect complete all as specified & directed 62 Supply only PVC low level white flushing cistern valveless symphonic action type 5/10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified & directed 63 S&F in repairs 15 mm dia 600mm long PVC connectionswith brass check nut complete all as specified & directed 64 S&F in repairs Glass Corner Shelf 6mm thick including CP railing radius 250mm complete all as specified and directed by Engineer-in-Charge. 65 S&F in repairs Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with cp railingcomplete all as specified and directed by Engineer-in-Charge. 66 S&F in repairsHealth faucet, CP brass with 1.50m long flexible pipe complete all as specified and directed by Engineer-in-Charge. 67 S&F fancy type brass chromium plated toilet paper holder, complete all as specified & directed 68 S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule Make-Jaquar/marc/Kohlar, complete all as specified & directed 69 S&Fin repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as specified & directed 70 S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as specified & directed 71 S&Ffor 15 mm bore gate valve, gun metal, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed 72 S&Ffor 20 mm bore gate valve, gun metal, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed 73 S & F in repairs Chromium plated brass overhead shower with arm complete all as specified and directed. 74 S&F in repairs looking mirror of size 600mmx450mmx5.5mm thick with aluminium frame selected quality mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 75 S&F in repairs Brass chromium plated mode 2 in 1 WHB mixture model Quarter half turn (SOLO) omplete all as specified & directed. 76 S&F in repairs brass chromium plated mode 3 in 1 wall mixture model Quarter half turn (SOLO) complete all as specified & directed 77 S&F in repairs Brass chromium plated mode 2 in 1 sink mixturemodel Quarterhalf turn (SOLO) ofas complete all as specified & directed. 78 S&F in repairs chromium plated soap dish fancy type complete all as specified & directed 79 S & F in repairtowel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embedded in cement mortar 1:3 with MS screws etc complete all as specified and directed. 80 Dismantling of floor of size not exceeding 4.00 Sqm each for EWC and removing out the cinder/concrete from sunken protion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditons, grinding any sharp edges etc all as specified and directed. (a) Cleaning or RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite.(c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified.(d) M&L for providing 25mm dia GI pipe spout projecting at least 150mm beyond outer face of wall.(e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(f) The area of Each WC portion is n.exc 4.00Sqm each.(g) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.Note : The work will be executed by authorised manufacturers/applicator. 81 Dismantling of floor of size not exc 1.50 Sqm for IWC and removing out the cinder/concrete from sunken protion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditons, grinding any sharp edges etc all as specified and directed. (a) Cleaning or RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite.(c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified.(d) M&L for providing 25mm dia GI pipe spout projecting at least 150mm beyond outer face of wall.(e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(f) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.Note : The work will be executed by authorised manufacturers/applicator. 82 Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed. 83 M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqmbut not exceeding 0.11 sqmas in floors over and including 15mm thick screed bedin cement mortar 1:4 set and jointedin neat cement slurry and pointed in coloured cement. complete all as specified and directed 84 S&F for glazed Ceramic tiles 9 to 10 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.. 85 All as per item no. 84 here in before but on vertical surfaces as in skirting etc over and including 10mm thick screed bed in CM 1:3, set and jointed in white cement with pigment to match all as specified and directed. 86 M&L glazed ceramic coloured tiles in vertical surface600x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 10mm thick in CM (1:3) complete allas specified & directed. 87 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc incl brushing neat cement slurry with 3.0kg of cement per sqmtr complete all as specified and directed. 88 M&L for Granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms with necessary hole for gas pipe where ever required and likes over and including cement mortar bedding of 20 mm thick in CM 1:4 including pointing in white cement using marble dust with admixture of pigment to match including rounded edges with shade of granite complete all as specified and directed. 89 M&L for machine cut kota stone slab flooring, and (one Pieces) as in tread, riser, landing, 20-25 mm thick over and including cement screed bed 20mm thick in CM 1:4laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. 90 M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 53 grade and two part ofsand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete all as specified and directed Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer).(c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. 91 M&L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water.All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint complete all as specified and directed. 92 Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially providedincluding removal of rubbish out side complex (MOD land), complete all as specified and directed 93 M&L for 75 mm thick cement concrete 1:3:6type C2(using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished even and smooth without using extra cement, complete all as specified and directed 94 M&L for 40 mm thick cement concrete 1:2:4type B0(using 12.5mm graded stone aggregate) as in floor & surfaces finished even and fairusing extra cement, complete all as specified and directed 95 Demolition of reinforced cement concrete in any position complete all as specified and directed 96 M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm stone crushed graded aggregate) as in louvers and jallies 25mm thick designed as fort pattern (measured solid) including all moulding but exceeding frame and set in CM1:4 all as per sample shown complete all as specified and directed 97 M&L for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone crushed aggregate) as in roof slabs, slab supported on walls, cooking platform, beams and columns, in floors roofs, landings, balconies, canopies and in chajjas, parapet, shelves and the like complete all as specified and directed. 98 Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed. 99 S&F TMTmild steel bars of 10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed. 100 Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortar of any diameter including bends complete all as specified and directed . 101 S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears ,110mm bore complete all as specified and directed . 102 S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears 75 mm bore complete all as specified and directed 103 S&F for PVC (SWR) bends & tee any radius, 110 mm bore complete all as specified and directed. 104 S&F for PVC (SWR) bends & tee any radius, 75 mm bore complete all as specified and directed. 105 S&F for PVC (SWR) door plates , Yjunction 110 mm bore complete all as specified and directed. 106 S&F for PVC (SWR) door plates ,T junction 110 mm bore complete all as specified and directed. 107 S&F for 100 PVC (SWR) bends with door plate& teecomplete all as specified anddirected. 108 S&F for 75 mm PVC (SWR) bends with door plate & tee complete all as specified anddirected. 109 S&F for 75 mm bore PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in solvent cement concrete complete all as specified anddirected. 110 S&F in repair 20 mm nominal dia and minimum thickness 1.2mm of SS-304 Grade of Stainless Steel tubefor curtain rod including pair of suitable S.S brackets approved by GE including taking down old pelmet boxes with curtain rods complete all as specified and directed. 111 Dismantling wrought iron or mild steel work of any description not otherwise provided for parapet railing, balconies, tank staging, metre rooms shaft areaany descriptioncompleteas specified and directed. 112 Supply and fix welded steel wire fabric(MS Jali) fixed to steel members weight n. exc. 4 kg/sqm including welding complete all as specified and directed. 113 S&F rolled sections as in main and cross beams, hip and jack rafters; purlins , pillars, trusses , water tank stage , framed guard bars, barred iron doors, ladders, frame balusters, walk ways, railing and similar work where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed 114 Dismentling asbestos cement corrugated orsemi corrugated sheets in roof fixed with L hook or cranked bolt complete all as specified and directed 115 S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge 116 S&F in repairs two legged aluminium floor door stopper with rubber shoe 140mm long complerte all as specified and directed by Engineer-in-Charge. 117 ROAD, PATH AND CULVERT 118 Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially providedincluding removal of rubbish out side complex (MOD land), complete all as specified and directed 119 M&Lfor 75 mm thick PCCtype D-2 1:4:8 (40mm graded aggreate) as sub-base complete all as specified and directed 120 S&F Endura colour paving tiles 30cm X 30cm x 15-20mm double charged digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. 121 M&L for Providing PCC in coping type B-1, 1:2:4 using 12.5mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified and directed 122 M&L for broken stone boulders of hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed 123 SEWAGE DISPOSAL 124 Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loosesoil complete all as specified and directed 125 Returningfilling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed 126 Removing excavated materials to a distance exc 1.50 Km but not exc 5 Km outside defence land and depositing where directed complete all as specified and directed 127 M&L for PCC 1 : 4 : 8 type D2 using 40mm graded stone crushed aggregates as in foundation of manholes, posts etc completeall as specified and directed. 128 M&L for PCC 1 : 2 : 4 type B1 using 20mm graded stone crushed aggregates as in surfaces channels and drains complete all as specified and directed. 129 Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stoped ends etc complete all as specified and directed. 130 S&F DWCPE(SN8) 150mm dia (Internal Dia)pipes, snap fit coupler and rubber ring including testing and laid and properly jointed laid in trenches to a level on concrete bed complete all as specified and directed. 131 Demolition of brick work built in cement orcement lime mortar of any description including quoins,arches,pillars,etc., complete all as specified & directed 132 M&L for Brick work with sub class ‘B’ bricks straight or curved on plan, built in cement mortar 1:4 using old size bricks complete all as specified and directed. 133 All as per item no 130 here-in-above but except bricks 134 M&L for PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Itemwater troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed. 135 M&L for precast factory made manhole cover, area of each cover n.exc 0.60 Sqm, 100mm thick with SFRCconcretingincluding grove and hook arrangement for lifting and placing in position and sides covered by MS sheet complete all as specified and directed. 136 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100mm internal dia pipe, complete all as specified. 137 M&L for rendering 15mm thick on top of roof concrete in cement mortar 1:4 with water proofing compound @ 3% by weight of cement to have a smooth surface for laying of water proofing membrane. Note: Water proofing compound will be measured and paid seprately. 138 Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),150 mm diapipe of any description and in any position set and jointed in cement mortar complete all as specified and directed by Engr-in-Charge 139 INTERNAL ELECTRIFICATION 140 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc 141 Taking down old MCCB , TPN DBs , SPN DBs (incl MCB SPN & SP) & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed. 142 Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. 143 Disconnecting elect connection and taking down of ceiling fan/ Exhaust fanof any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge. 144 M&L for point wiring complete with 1.5 Sqm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit of 20 mm nominal diaand conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and including provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel concealed in walls, with modular sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, complete all as specified and directed for the following:- 145 One light /Ceiling fan/exhaust fan point controlled by one switch. 146 One light point controlled by two, two way switch ( switch to be measured and paid separtely) 147 One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. 148 One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board 149 One bell point controlled by one bell push. 150 All as per item Ser No 142 here-in-before but point wiring with 2.5 sqmm single core FRLS 1100 Volts in New PVC concealed conduitmedium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 2.5 sqmm single core FRLS 1100 Volts copper conductor cableas earth continuityconnected to common earthfor one 15 A switch socket power point, complete all as specified and directed 151 M&L for submain wiring 4 Sqmm nominal cross sectional area,two single core, 1100 Volts grade, multi-stranded, PVC insulated unsheathed, FRLSHcopper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of suitable dia, medium grade with all conduit accessories and connected to common earth dolly to suitable copper lugs including all cutting/chases etc in walls and making good to the disturbed surfaces to match the existingsurfaces.Note:- Three run of single core wire andone run of conduit shall be measured and paid as one unit complete all as specified and directed 152 All as per item ser No 144 here-in-before but for 02 x 6 Sqmm for phase & neutral and 01 x 6 Sqmm for continuousearth wire concealed/surface 153 M&L for switch Modular type 6 Amp one wayISI marked complete all as specified and directed. Make : Legrand Cat Part No 573400 / Schnider Cat No X1001WH / Wipro Cat No RF 110 154 M&L for switch Modular type 6 Amptwo wayISI marked complete all as specified and directed. Make : Legrand Cat Part No 2573402/ Schnider Cat No X1002WH/Wipro Cat No RF 210 155 M&L for switch Modular type type 16 Ampone way,ISI marked complete all as specified and directedMake : Legrand Cat Part No 573410/ Schnider Cat No X11001WH/Wipro Cat No RF 130 156 M&L for Modular type socket outlet 2 in 1, 5 pin 6 Amp ,ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573424/ /Schnider Cat No X2005WHNS/Wipro Cat No R 1212 157 M&L for Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573471/ Schnider Cat No X2106WH/ Wipro Cat No R 1332P 158 M&L for ceiling rose 3 phase PVCpolycorbonate,isolated body, complete all as specified and directed 159 M&L for bell push,modular type, 6 Amp, 1 moduleISI marked complete all as specified and directed.Make : Legrand Cat Part No 573413/ Schnider Cat No X1005WH/ equivalent in Wipro 160 M&L for bell ding dong AC, 230 volts, single pole complete all as specified and directed. 161 M&L for angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified anddirected. 162 S&F LED bulb 12 watts, 1200 lumens output, 6500K suitable for B-22 base complete all as specified and directed. 163 M&L for earthing complete with GIelectrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earthplate not less than 1.50 mtr below normal ground level connected to GI wire 4.0 mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze drilled and screwed all as specified including excavation and earth work and disposal of surplus soil incl 15 mm GI tubing light grade and necessary fitting for protection of GI wire incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MSangle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised wire and protection light grade GI pipe upto 7.5 mtr, excavation, etc shall be deemed to be in the quoted rates. 164 S&F sheet metal enclosure distribution board confirmingto IEC - 61439-3, single pole and neutral, AC 240 volts, 08 way witn 100 Amps rated copper bus bar and metal double door with IP-43 & IK 09protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete ( Note - MCB & DB shall be of same make) 165 S&F sheet metal enclosure distribution board confirmingto IEC - 61439-3, single pole and neutral, AC 240 volts, 12 way witn 100 Amps rated copper bus bar and metal double door with IP-43 & IK 09protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete ( Note - MCB & DB shall be of same make) 166 S&FMCB confirming to ISI/IEC -60898-1 (2002), SPN, AC, 240 volts, of 40Amps capacityB curve, 10 kA breaking capacity & making connection by using using suitable copper lugs complete all as specified and directed. 167 S&FMCB confirming to ISI/IEC -60898-1 (2002), SP, AC, 240 volts, of 6-32Amps capacityB curve, 10 kA breaking capacity & making connection by using using suitable copper lugs complete all as specified and directed. 168 Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 120 Lumens/watt andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. 169 S&F in replacement of LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.90, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 140 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥120 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. 170 M&L for in replacement Decorative wall mounting CITY-1 Decorative wall light fixture made up of Polycarbonate,Power Factor > 0.90 voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 110 Including 12 W retrofit LED BULB (B-22 base). NOTE- one piece of LED bulb 12 watts included with city -1 fitting complete all as specified and directed. 171 Supply and fix in replacement 10 watts bulkhead fitting, IK 09 with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover,including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. 172 Taking down existing electric meter & refixing the same after completion of job with electric connection by 8 way DB in good way by cleaning and qtr No. marking complete all as specified and directed.. 173 Supply and fixingexhaust fansmetal body AC single phase 230/240 V of size300 mm sweep, Air flow rate > 900cum/min, Bird screen forprotectionagainst birds, double ball bearing, metal body with louvre also with louvre for fixing of exhaust fan complete all as specified and directed. 174 Supply and fixing new BLDC fan against old ceiling fans BLDC conversionthree blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5star rating for energy saving, rated Air delivery >220 cum/min,AC single phase 230/240 V of size 1200 mm sweep including fan regulators,down rod, canopy & all accessories including making connection with three core flexible, copper winding in fan,copper cable pvc insulated of suitable length, complete all as specified and directed. NoteBLDC Fan should work onelectronic fan regulator & also with remote controled. 175 S&F modular type sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall complete all as specified and directed. 176 S&F of water heater storage type Geyser vertical type with suitable size of fastner and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity including provision and connecting up of SS braidedpipe with adopter for inlet and outlet wwater connection having edjustable knob for temperature control and inner tank should be glass line coated, capacity25 Ltrs, having heating element 1.5 KW and not less than 5 star rating,suitable for ,230 volt,50 Hz electric supply complete all as specified and directed . 177 S&F fresh air fan PVC body air delivery > 800 CMH , 5 number of blades, AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed. 178 S&F in replacement pressure die cast aluminium housing LED street light luminaires with IP-66 deg. of protection suitable for 35 watt LED fitting, Power Factor > 0.90 voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 110 duly fixed on 25 mm dia GI pipe light grade including 40 X 6 mm thick MS flat with suitable size of fastner including making connection flexible copper conductor cable from ceiling rose to fitting complete all as specified and directed. Note : Quoted rates shall be inclusive of all accessories like suitable GI pipe, 40x6 mm thick MS flat, fastner, nut & bolts, suitable length of flexiable wire etc. 179 S&F in repair factory made epoxy powder coated Distribution Board VTPN-4 ways (IP-43 protection), mechanical impactstrength IK - 09, with cement spill protector double doorfabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one MCCB 125/160 Amp as incomer and12 Nos of SP MCB 10 to 63 Amps outgoing and conforming to HSN code : 8537 complete all as specified and directed. Note :- MCCB & MCB will be measured & paid separately. 180 S&F in replacement MCCB 125 Amps, thermal magnetic release,4 pole 16 kA ICS=ICU Complete all as specified and directed.
Contract Date: May 30, 2026 Contract Value : 3.02 Crore
Statutory Bodies & Commissions/Committees No of Bidders 11
15.
Public Administrative Department #11192895 AOC
Tender For Osd At Samantara Sahi In W.No-1 Of Nac Ganjam- 1 Earthwork in excavation of foundation in hard soil including dressing and levelling the bed and depositing the soil away from the working area as directed by the EIC 2 Providing ,Supplying , filling in foundation and plinth with sand including watering with cost, conveyance , Royality taxesof all materials with all labour , T & Petc. Complete. 3 Metal concrete (1:4:8) using 40mm size CBG metal with all cost of material, labour, conveyance, royalty, taxes T and P etc. complete. 4 Supplying all materials, labour, T&P and providing reinforced cement concrete work of M-20 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the E.I.C 5 pillar base & plinth band 6 pillar 7 Foundation 8 superstructure 9 Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:6) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the E.I.C 10 Supplying all materials, labour, T&P and providing 16mm thick cement plaster (1:6) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the E.I.C 11 6mm thick cement plaster in cm (1:4) finished smooth to brick masonry including racking out joints including watering, curing, cost, conveyance, taxes, royalties, labour with T&P etc. complete in all respect. 12 Wall painting two coats with weather coat of approved shade & approved make to give an even shade etc including cost of all materials, taxes & labour with T&P etc. complete in all floors as per the direction of EIC. 13 Wall priming one coat with approved wall primer etc including cost of all materials, taxes & labour with T&P etc. complete in all floors as per the direction of E-I-C. 14 Supplying fitting and fixing of precast garden chair including all cost and colouring etc complete as directed by the EIC. 15 Rejuvenation & Renovation of well with excavation of inside slushyearth,garbages,C&D materials etc properly and manually with all costs complete. 16 Fixing of industrial vertrified tiles in floors, Trades of steps & Landing over 25mm thick bed of cement mortar 1:1 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect. 17 Supplying, fitting and fixing of GI grill in Door&windows (Frame with Shutter) including screws as may be required etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect. 18 Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the E.I.C 19 provision for plantation with pot 20 Photography and displayboard Please Enable Macros to View BoQ information
Contract Date: May 30, 2026 Contract Value : 6.40 Lakh
Local Bodies No of Bidders 2
16.
Defence #11191790 Price Bid
Tender for Dismantling Plain Or Corrugated Steel Sheeting Any Guage, Thickness, Including Nainital Pattern Or Similar Pattern Roof Covering Complete All As Specified And Directed. , S&F 0.63Mm Thick Galvanised Corrugated Ms Sheeting (Cgi Sheet Roofing) With Two Corrugation Side Laps, With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusive Fixed With Coach Screws And Washers As In Roofs Etc All As Specified , S&F 0.63Mm Thick Plain Galvanised Ms Sheeting Using Grade-O Sheets With 120Gm Zinc (Spelter) Coating Per Sqm Both Sides Inclusives, As In Roof, Ridges, Hips, Valley Gutters, Drip And Straight Flashing Complete All As Specified And Directed. , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa (Az 150) As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall , Fixed With Self Tapping Screw As Specified And Directed , Demolition Of Brick Work Or Stone Masonry Precast Plain Cement Concrete Block Walling Built In Cement Mortar Complete All As Specified And Directed. , M&L For Brick Work With Sub Class B Bricks Using Old Size Bricks Straight Or Curved On Plan Exc 6 Mtr Mean Radius, Built In Cm 1:6 All As Specified And Directed. , M&L For Precast Cement Concrete Block Masonery With Solid Block Of Cement Concrete 1:3:6 Type C-1 ( Using 20 Mm Graded Stone Aggregate) Exc 10 Cm In Width And Setting In Cm 1:6Complete All As Specified And Directed By Engg-In- Charge , Taking Down Cement Or Cement Lime Plaster Of Any Description On Brick Or Plain Cement Concrete Blocks Or Stone Wall Or Concrete Surface Etc Including Racking Out Joints, Hacking For Keys, Scrubbing Down With Water Etc All As Specified And Directed. , M&L For Rendering 15 Mm Thick Readymade Plaster On Inner/Outer Walls By Adding 17-19% Of Potable Water By Weight Of Material For Thickness Above 15Mm It Is Recommended To Be Applied In Multiple Layers. Ready Mix Plaster Shall Complies With Is 1661-1972, Is 2250-1965, Is 2402-1963 And Confirms The Compressive Strength @ 28 Days 10-12 Mpa/Bulk Density 1500-1600 Kg/M3. (Note : The Rate Quoted By Contractor Shall Include Cleaning Of Surface, Application As Per Instruction And Scaffolding Upto 20 Mtr Ht All As Specified And Directed) , M&L For Applying Two Coats Of Cement Base Paint Over A Coat Of Primer On Newly Plastered Surfaces Of Walls Including Preparation Of Surfaces Complete. , (M&L For Preparation Of New Plastered Surfaces & Applying A Layer Of Birla Putty 3Mm Thickness On Wall Surfaces Including Cornics Etc For Proper Levelling Of Plaster And Two Coat Of Oil Emulision Distemper Complete All As Specified And Directed. , (M&L Three Coats Of White Wash On Walls Including All Preparation Complete , M&L Preparation Of Old Surfaces Including Cornices Etc And One Coat Of Oil Bound Distemper Complete All As Specified And Directed. , M&L For Preparation Of Old Plastered Surfaces & Applying A Layer Of Birla Putty On Wall Surfaces Including Cornics Etc For Proper Levelling Of Plaster And Two Coat Of Oil Emulision Paint Complete All As Specified And Directed. , Dismantling Of Ceiling Board (Flbre Pulp, Insulation Etc) Or Insulation Boards/Slabs/Blankets Any Thickness, Including Cover Fillets Complete All As Specified And Directed. , S&F Of Powder Coated Grid Frame Work For False Celling Comprising Of The Following Sections For Making Partitions Of 600X600 Mm Size Fixed To Walls With Rawl Plugs & Screws And Hanged To Roof With And Including 4Mm Dia Gi Wire Suspender Of Suitable Length And Butterfly Clips, Size Of Main Tee Shall Be 28Mmx24mmx0.3Mm Thick , Cross Tee Shall Be 28Mmx24mmx0.3Mm Thick And Wall Angle Shall Be 24Mmx24mmx0.3 Mm Thick Incl 4 Mm Thick E-Board Classic (Make-Everest) For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Snap Grid As In Ceiling With And Including Dusting Of Surface Complete All As Specified And Directed.Complete All As Specified And Directed , S&F Solid Pvc Wall Lining Dual Colour Consisting Of 5 Mm Thick Wood Grain Printed Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame As Per Specification And Drawing Complete Fixing Arrangement Icluding Taking Down Old Existing Wooden Panelling Complete. , S & F For 5Mm Thick Pvc Sheet Fillet Of Width 35Mm For Wall Paneling Inclusive Of Fixing On To Wall To Make Pvc Frame As Per Specification And Drawing. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exc 15Cm Thickness (Below Or Above Ground Level) Complete All As Specified And Directed. , M&L For Cement Concrete 1:4:8 Type D-2 (Using 20Mm Graded Stone Agg) As In Foundation , Filling And Mass Concrete Complete All As Specified And Directed. , M&L 40 Mm Thick Plain Cement Concrete Type B-1 (1:2:4) Using 20 Mm Graded Stone Aggregate As In Flooring Finishing Cement Concrete Even And Smooth With Using Extra Cement Complete All As Spd , Surface Channel In Concrete 1:3:6 (40 Mm Graded Aggregate) For Drain Complete All As Specified And Directed. , Extra For Forming Fair Finished Drain Or Channel 30 Cm Inner Girth In Cement Complete All As Pecified And Directed. Concrete, Using Ex- Tra Cement, Including Forms, Moulds, Mi- Tred/Stopped Ends Etc.All As Specified And Directed. , M&L For 75Mm Thick Cement Concrete 1:3:6 Type C-2 (Using 40Mm Graded Stone Agg) As In Plinth Protection Laid To Slope In Bays And Finishing The Surfaces Of Concrete Topping Fair And Even And Exposed Edges Fair Or Rounding Or Chamfering Laid In Panels Wit , M&L Chequred Tiles 300 X 300 X 25 Mm Coloured Glossy Finish Rubber Pressed Moulded Of Approved Pattern & Shade Make As Approved By Ge As In Floor Over 15 Mm Thick Screed Bed Or Bedding Layer In Cm(1:4) And Jointed Complete All As Specified And Directed. , M&L Interlocking Tiles 75-80 Mm Coloured Rubber Pressed Glossy Finish Thick Of Approved Pattern & Shade Isi Marked Or Approved By Ge Set Jointed Over 40 Mm Th Fine Sand Cushion Including Sides Are Tappered 75 Mm In Width By Plain Cement Concrete 1:3:6 Type C1 (Using 20Mm Graded Crushed Stone Agg.) Complete All As Specified And Directed. , Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And Directed. , Dismantling Of Timber Scantling 40 Sqcm And Over In Section In Any Position As In Framed Work Complete All As Specified And Directed , M&L For 2Nd Class Hard Wood Clean Sawn In As In Scantling Framed And Over 40Sqcm Fixed With Screws Etc All As Specified And Directed. , S&F 18Mm Thick Mdf Board Both Side Finished As In Wardrobe/ Cup Board Shutter All As Specified And As Directed By Engineer-In-Charge. , Dismantling Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors Laid Bedded And Pointed In Any Mortar, Aprons Etc. , M&L Plain Cement Concrete 1:5:10 Type E2 Using 40Mm Graded Aggregate As In Sub Base Complete All As Spd , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing) Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. , M&L 300X450x7mm Thick Glazed Ceramic Digital Tiles Coloured Incl , Design And Pattern As Approved Fixed As In Vertical Surface Etc, Set And Jointed In Neat Cement Slurry And Pointed With White Cement With Colour Pigment To Match Incl Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 Complete All As Specified And Directed. , M&L Colour Non Skid Ceramic Tiles 7 To 8 Mm Thick ( Square/ Rectangular) Area Of Each Tiles Exc. 0.11 Sqm But N.Exc. 0.18 Sqm In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Cement With Colour Pigment Incl 15Mm Thick Screed Bed In Cm 1:6 Complete All As Spd , M&L Colour Non Skid Ceramic Tiles 7 To 8 Mm Thick ( Square/ Rectangular) Area Of Each Tiles Exc. 0.18 Sqm But N. Exc. 0.38 Sqm In Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Cement With Colour Pigments Incl 15Mm Thick Screed Bed In Cm 1:6Complete All As Spd , M&L Colour Non Skid Ceramic Tiles 7 To 8 Mm Thick ( Square/ Rectangular) Area Of Each Tiles Exc. 0.18 Sqm But N. Exc. 0.38 Sqm In Skirting /Dado Etc Set And Jointed In Neat Cement Slurry And Pointed In White Cement With Colour Pigments Incl Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 Complete All As Specified And Directed.Complete All As Spd , M&L 18 To 20 Mm Thick Granite Stone On Steps Including Rubbing And Polishing And Making Hole For Gas Pipe And Front Portion Rounded And Chamfered Complete Including Screed Bedding 15 Mm Thick In Cm 1:4 Complete All As Spd , S&F In Repairs Parquet Flooring 8.3 Mm Thick Hard Board Plank Both Side Laminated With Decorative Surface And Approved By Ge Laid Above The Thermoplastic Sheet Complete All As Spd , Taking Up Or Down 15Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , Taking Up Or Down 20Mm Dia Steel Tubing And Connections By Disconnecting Fittings/Tubing From Existing Tubing Were Required Including Cleaning For Refixing Or Removal From Site Complete All As Specified And Directed. , M&L For 15Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , M&L For 20 Mm Bore Gi Tubing, Medium Grade, Galvanised With And Including All Gi Fittings And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , S&F In Repair 15Mm Dia Bib Tap Long Body Cp, Screwed For Iron Pipes Complete All As Specified And Directed , S&F Angle Cock 15 Mm Bore Brass Chromium Plated, Screwed Both Ends For Pipes Or For Unions Fixed In Repairs Including Making Good To Match With Existing Surface , S&F In Repair Pillar Taps 15 Mm Bore, Brass Chromium Plated , Screwed Down High Pressure With Or Without Letter Hot Or Cold With Long Screwed Shanks And Fly Nut Complete All As Specified, Fixed In Repairs. , S&F Bib Tap Standard Of Ptmt (Polytetra Methylene Terephthalate Engineering Thermoplastic Bath Fitting), Any Colour, Screwed Foriron Pipe 15 Mm Bore Pipe (Minimum Weight 90 Gm) All As Specified, Fixed In Repairs (Make : Prayag Or Equivelent As Approved) , S&F In Repair Polymer White (Polypropeylene Delrin And Abs) Low Level Flushing Cistern 10 Ltrs Capacity, Valveless, Syphonic Action Type Complete With Inlet, Ball Valve Float Valve, Bends Brackets, Rawl Plug, Brass Screws Handle Etc Complete, Complete All As Specified And Directed. , S&F In Repairs, 550X400mm Vitreous China, Wash Hand Basin , Flat Back With Pedestal Excluding Trap And Waste Chain And Plug And Porcelain Stopper Including Sutaible Size Brackets Waste Pipe And Waste Coupling Complete All As Specified And Directed. , S&F Vitreous China Squatting Pan Orrissa Pattern Size 580 X 440 Mm White With Intregal Foot Rests, With & Including P Or S Trap (Excluding Material & Labour Of Flushing Cistern And Flush Pipe) Including Conection To Trap And To Flush Pipe Etc Complete Including Making Good To Floor Complete All As Specified And Directed Fixed In Repairs. , Dismantling Water Tanks 500 Ltrs Capacity Complete All As Specified And Directed. , Dismantling Water Tanks Of Any Description, Capacity Exceeding 500 Litres But Not Exceeding1000 Liters Complete , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 500 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Make - Prayag Complete All As Specified And Directed. , S&F Rotational Moulded Polythene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Postion 1000 Ltrs Capacity And Including 20Mm Dia Ball Valves, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Minimum Weight 210 Gram Of Make - Prayag Complete All As Specified And Directed. , S&F 20 Mm Dia Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Road & High Density Plastic Ball Screwed For Iron Pipe And Fixed In Repairs (Min Weight 210 Gm). , S&F 15 Mm Dia Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Road & High Density Plastic Ball Screwed For Iron Pipe And Fixed In Repairs (Min Weight 210 Gm). , S&F Pvc Circular Top Cover Suitable To Rotational Moulded Polyethylene Water Storage Tanks Of 500 /1000 Litres Capacity Tanks Of Standard Mares, With 6 Mm Dia Nut And Bolts On Two Ends Of Cover To Act As Hinge As Will As Locking Arrangement For Side Opening , S&F In Repairs Sinks With Drainage Board Made Of Stainless Steel 1Mm Thick Kitchen Or Laboratory With Plugs,Washers And Wastes,Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cautilever Brack Etc And Connecting Union To Pipe Over All Size 915Mmx460mm Bowl Size 405Mm X 354Mm X 178Mm As Approved By Gecomplete All As Specified And Directed. , S&F Pvc Whb Waste Pipe 32/40 Mm Dia Compolete All As Spd , S & F In Repairs 15 Mm Bore Fancy Type Chromium Plated Wall Mixer With Provision For Overhead Shower With 115Mm Long Bend Pipe On Upper Side, Connecting Legs And Wall Flanges, Screwed Down High Pressure With Or Without Lettered Hot And Cold Screwed For Iron Pipe Complete All As Specified And Directed. , S&F, 5.50 Mm Thick Looking Mirror Of Selected Quality Glass, Size 60 Cm X 45 Cm, Mounted On 6Mm Thick Commercial Plywood And Fixed To Wooden Plug With C.P. Brass Screws And Cup Washers With & Including Plastic Fancy Frame Alround All As Directed. , Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Not Exc 1.5 Sqm Each.& Removing To Or From Store All As Specifed & Directed. , Taking Down Chowkats Or Frames Exc 1.5 Sqm But Not Exc 4 Sqm Each With Shutters (Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , M&L For Second Class Hard Wood Plain, Solid, Straight Chowkats And Frames, Wrought, Frame Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue Pinned At Joints Complete All As Specified And Directed. , S&F Factory Made 35Mm Thick Plain Framed, Panelled Shutter (Two Panel) With Lock Rail And Panel Of 9 Mm B.W.P. Commercial Ply Or 12 Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per Is : 1003 (Part I), Kiln Seasoned And Chemically Pressure Treated All As Specified , S & F 35 Mm Thick Second Class Hard Wood Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze, Etc., Rs, Edges Of Framing Plain, Chamfered Complete All As Specified And Directed. , Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door/ Window/ Ceosetory Window & Other Frames/ Chowkhat Of Size 45 X 70 Mm Comprising Of Pvc Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wwod Powder/ Rick Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Stat Headed Ss Screws Having Minimum Frame Density Of 750 Kg/ Cum, Screw Withdrawal Strength Of 2200 N (Face) & 1100 N (Edge), Minimum Compressive Strength Of 58 N/Mm2, Modules Of Elasticity 900 N / Mm 2 And Resistance To Spread Of Flame Of Class A Catogory With Property Of Being Termite/ Borer Proof, Water / Moisture Proof And Fire Retardant And Fixed In Position With Ms Hold Fast/Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge (M.S. Hold Fast/ Lugs Or Ss Dash Fasteners Shall Be Paid For Separately). , Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Plain Flush Door Shutter Of 35 Mm Thick Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Having Minimum Density Of 650 Kg/ Cum And Screw Withdrwal Strength Of 1800 N (Face) & 900 N (Edge), Minimum Compressive Strength 50 N Mm2 Modulus Of Elasticity 850 N / Mm2 And Resistance To Spread Of Flame Of Class A Catogary With Property Of Being Termite/ Borer Proof, Water/ Moisture Proof And Fire Retardanat And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws, All As Per Direction Of Engineer-In-Charge (Note:- Stainless Steel Butt Hinges And Necessary Ss Screws Shall Be Paid Separately. , S&F Aluminium Powder Coated Door With Shutter And Frame Of Aluminium Section Sliding Type As Per Following Specifications With And Including Round Type Aluminium Handle, Tower Bolts, Hinges, Panes Etc And As Directed At Site. Make Jindal Or Its Equivalent Approved Make:- (A) Door Frame : 100 X 44 X1.6 Mm Section For Complete Frame. (B) Door Shutter : Top & Bottom Rail Of 100X44x1.6 Mm, Middle Rail Of 83 X 44 X 1.6Mm, Both Styles Of 83 X 44 X 1.6 Mm Size Shall Be Used. (C) Glass Pane : 5Mm Thick Sun Broken Glass Fixed With Gasket With Aluminium Clip , Jointing Clips, Glazing Clips, Rubber Packing, Screws Etc. (D) Jointing Cleats, Glazing Clips, Rubber Packing, Anodized Aluminium Snap Beading, Screws, Anodized Aluminium Fittings Such As 100Mm Long 03 Nos. Hinges, Aluminium Handles , Aluminium Tower Bolts ,And Mortice Lock 6 Levers Etc Complete All As Specified And Directed , M&L For Taking Down Existing Aluminium Door Shutter Carefully Without Damage Of Glass Panesincluding Replacing Aluminium Clip , Jointing Clips, Glazing Clips, Rubber Packing, Screws Etc As Reqd At Site And Refixing The Same After Complete Repairs All As Specified And Directed ( Note- Any Replacement Of Aluminium Rails Or Stiles If Reqd To Be Replaced Will Be Measured Seperately ) , S&F In Repairs Double Action Floor Spring Hydraulicaly Regulated Made Up Of Minimum 1.25Mm Thick Aluminium Alloy Sheet Foundation Box Main Body With Stainless Steel Cover Governing Pivot Made Brass Other Parts Made Of Mild Steel Heavy Duty And Fixed Complete All Specified , S&F Aluminium Partition Powder Coated Of Frame Of Aluminium Section 44.45 X 44.45 X 1.6Mm Etc And 5 Mm Thick Sun Broken Glass Fixed With Gasket With Aluminium Clip , Jointing Clips, Glazing Clips, Rubber Packing, Screws Etc.And As Directed At Site. Make Jindal Or Its Equivalent Approved Make Including Taking Down Old Userviceable Wooden Partition Completeall As Spd , S&F 100Mm Size Ms Butt Hinges, Medium Weight, Cold Rolled And Fixed Complete All As Specified And Directed. , S&F 150Mm Long Aluminium Tower Bolt And Fixed Complete All As Specified And Directed. , S&F 125 Mm Size Aluminium Handle Plate Type Anodised Complete All As Specified And Directed. , S&F In Repairs Hydraulic Door Closer Aluminium ( Die Cast) Regulated Designation No-3 Universal Type For Door Shutter Complete All As Spd , Hacking Out Old Broken Glass (Any Thickness, Size, Quality Or Description) From Wooden/Metal Frames, Glazed With Putty Or Fixed With Beads Including Punching Or Drilling Out Old Glazing Pins/Spring Clips And Providing And Fixing New Ones All As Specified , S&F 3 Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. , S&F In Repairs Of Galvanised Mild Steel Wire Cloth 0.45 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.18Mm And Fixed With Tinned Tacks Or Galvanised Wire Staples Complete All As Specified And Directed. , M&L For Preparation Of New Or Previously Untreated Wooden Surfaces Of Any Description,Not Otherwise Described Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Specified And Directed. , M&L For Plain Cement Concrete 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Fixing Of Hold Fast, Bed Blocks Etc Including Necessary Form Work As Required Complete All As Specified And Directed. , Demolition And Breaking Up Drains Pipes(150Mm Size) Salt Glazed Ware, Ac Or Reinforced Concrete Set In Cement Mortar Complete All As Specified And Directed. , S&F 110Mm Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Wall And In Floors Complete All As Specified And Directed , S&F Of 75 Mm Bore Pvc (Swr) Pipe Single Socketed In As Length With Rubber Ring As In Vent Pipe Complete All As Specified And Directed , S&F In Repairs Of 110 Mm Dia Pvc (Swr) Bend Complete All As Specified And Directed. , S&F In Repairs Of 75 Mm Dia Pvc (Swr) Bend Complete All As Specified And Directed. , S&F Brass Chromium Plated Tubular Towel Rail, 20 Mm Dia, D; Type, 60 Cm Long Between Flanges Complete All As Specified And Directed. , S&F Chromium Plated Soap Disk Fixed To Plug With Chormium Plated Brass Screws All As Specified And Directed , S & F 20Mm Dia Aluminium Alloy Anodised Curtain Rod Decorative Fency Type With Brackets Complete All As Specified. , S&F Mild Steel Work As Hold Fasts, Bands, Straps, Supports Or Stays For Pipes Eaves Gutter Including Bolts If Required, Hooks (Stay), Clamps And Similar Small Articles, Conforming Tofe 310-0 Or Fe 410-0 Complete All As Specified And Directed. , Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For. , S&F Mild Steel Framed Work Such As Purlin , Truss, Square Tube , Ms Pole , Grating Etc With End Of Bars Shouldered And/ Or Riveted Or Forged Into Spikes, Framed Guard Bars, Barred Iron Doors, Ladders, Framed Balusters, Walk Ways, Railings, Welded Wire Mesh And Similar Work Confirming To Fe-290 Gde E-165 Complete All As Specified And Directed. , M&L For Preparation Of Old Or Previously Treated Wooden Surfaces Of Any Description,Not Otherwise Descri- Bed Over 10Cm Width Or Girth And Applying One Coats Of Synthetic Enamel Paint Complete All As Specified And Directed.. The Contractor Shall Make Necessary Arrangement Of Scaffolding And Ensure Safety Of Labours. , S& F In Repair Vitreous China Premium/ 1St Quality Wash Down Water Closet Wall Hung Ewc White/ Ivory/Off White (Closed Pattern Incl All Necessary Accessories Like Rag Bolts/ Gel Gasket Etc. (Excluding Flushing Cistern & Flush Pipe) Complete In All Respect All As Specified. , Health Faucet (Abs Body) Mild Steel Chromium Plated Suitable For 15 Mm Dia Pipe With 1.25 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified , S & F 20Mm Dia Aluminium Alloy Anodised Curtain Rod Decorative Fency Type With Brackets Complete All As Specified.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
Uttarakhand View Result →
17.
Defence #11191784 Price Bid
Tender for Taking Down Cement / Lime Plaster Of Any Description On Brick Work Or Stone Walls Etc Including Racking Out Joints Hacking For Key Scrubbing Down With Water Etc.Complete All As Specified And As Directed , M&L For Rendering 10 Mm Thick On Brick Or Concrete Surface Of Walls In Cement Mortar 1:6 Finished Even & Smooth Without Extra Cement On Internal Wall Surface Complete. , M&L For Rendering 15 Mm Thick On Brick Or Concrete Surface Of Walls In Cement Mortar 1:4 Finished Even & Smooth Without Extra Cement Including Mixing Only Water Proofing Compound As Per Manufacturer Instruction On External Wall Complete. Note:- Wpc Will Be Measured & Paid Separately , Supply Only Integral Water Proofing Compound , M&L For Preparation Of Newly Plastered Surfaces Of Wall And Applying Two Coat Of Oil Bound Distemper Over A Coat Of Primer Complete All As Specified And Directed , M&L For Preparation Of Newly Plastered Surfaces Of Wall And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , M&L For Preparation Of Newly Plastered Surfaces Of Wall And Applying Two Coats Of Weather Proof Exterior Emulsion Over A Coat Of Primer Complete All As Specified And Directed. , M&L For Preparation Of Old Decorated Surfaces By Washing, Rubbing Down And Stopping Of Painted , Plastered Or Un-Plastered Surfaces Of Walls And Applying One Coat Of Oil Bound Distemper White Or Tinted Complete All As Specified And Directed. , M&L For Preparation Of Old Decorated Surfaces By Washing, Rubbing Down And Stopping Of Painted , Plastered Or Un-Plastered Surfaces Of Walls And Applying One Coat Of Cement Base Paint Complete All As Specified And Directed. , M&L For Preparation Of Old Decorated Surfaces By Washing, Rubbing Down And Stopping Of Painted , Plastered Or Un-Plastered Surfaces Of Walls And Applying One Coat Of Weather Proof Exterior Emulsion Complete All As Specified And Directed. , M&L For Preparation Of Old Decorated Surfaces Of Plastered Or Un-Plastered Surfaces Of Ceiling And Applying One Coat Of White Wash Complete All As Specified And Directed. , M&L For Preparation Of Old Surfaces Of Steel Exc 10Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete As In Roof/Wall Cladding All As Specified And As Directed By Engineer-In-Charge. , M&L For Preparation Of Old Surfaces Of Steel Exc 10Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete As In Door/ Gates,Windows,Railings,Structural Horizontal & Vertical Members & Similar Work All As Specified And As Directed By Engineer-In-Charge. , M&L For Preparation Of Old Wooden Surfaces And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified & As Directed. , Material & Labour For French Polishing Two Or More Coats On Wooden Surfaces Of Any Description, Width Or Girth Including Cleaning And Preparing The Surface Including A Coat Of Wood Filler On Old Work Till To Obtain The Mirror Finish Look Of The Surface Complete All As Specified And Directed. , Demolition Of Brick Work Masonry/Precast Block/Stone Masonry Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars Etc But Excl Ashlars Facing,Dressed Stone Work And Pre-Cast Concrete Articles Complete All As Specified & Directed By Engr-In-Charge , M&L Brick Work With Sub Class B Bricks Straight Or Curved On Plan Exc 6M Mean Radius Built In Cement Mortar (1:6) Complete All As Specified & Directed By Engr-In-Charge , M&L For Rendering 15 Mm Thick In Cement Mortar 1:4 On Faces Of Brick Work Or Concrete Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Specified. , Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Over New Surfaces Complete All As Specified. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Premises.Complete All As Directed. , M&L For Non Skid Coloured Ceremic Tiles 7 To 8 Mm Thick (Square / Rectanguler) Area Of Each Tile Exceeding 0.11 Sqm But Not Exeeding 0.18 Sqm As In Floors Etc Laid Over And Including 15 Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:6, Set And Jointed In Neat Cement Slurry And Pointed With Coloured Cement To Match The Tiles Complete All As Specified & Directed By Engr-In-Charge. , M&L For Glazed Ceramic Coloured Tiles 300X450mmx7mm Thick On Wall/Vertical Surfaces Such As Skirting, Dados And Riser To Steps Etc Including Laid Over 10Mm Thick 1:3 Cement Mortar For Laying Wall/Vertical Finish Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match All Complete All As Specified & Directed By Engr-In-Charge. , M&L For Vitrified Ceramic Tiles 9 To10 Mm Thick (Square / Rectangular) Light Shade Polished Area Of Each Tiles Not Exceeding 0.36 Sqm As In Floors Etc Laid Over And Including 15 Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:6, Set And Jointed In Neat Cement Slurry And Pointed With Coloured Cement To Match The Colour Tiles Complete All As Specified & Directed By Engr-In-Charge. , M&L For Chequered Cement Concrete Tiles 25Mm Thick With Grey Cement & Pigment In Reqd Proportion, Set,Area Of Each Tile Exceeding 0.05 Sqm But Not Exceeding 0.09 Sqm, Jointed And Pointed In Near Cement Slurry In Floors,Laid On Screed Bed Or Bedding Layer Of Mortar 15Mm Thick 1:6 Cement Mortar Complete All As Specified & Directed , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exceeding 15 Cm Thickness.(Below Or Above Ground Level) Complete All As Specified And Directed. , M&L For 75 Mm Thick Plain Cement Concrete, 1:3:6, Type C-2, Using 40Mm Graded Stone Aggregate As In Path/Plinth Protection, Laid In Alternate Bays Including Finishing The Surfaces Even And Smooth Without Using Extra Cement All As Specified & As Directed. , M&L For Plain Cement Concrete Type B1 1:2:4 Using 20 Mm Graded Aggregate In Cills, Steps, Parapets , Copings, Kneelers, Apex Stones, Bed Plates, Kerbs, Flooring, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating, As Directed Complete All As Specified & Directed. , M&L For 75Mm Thick Plain Cement Concrete (1:3:6) Type C2 (Using 40 Mm Graded Stone Aggregate ) As In Sub Base To Floors And Paving Etc Complete All As Specified And Directed. , M&L For 100 Mm Thick Plan Cement Concrete 1:2:4, Type B1 (Using 20 Mm Graded Stone Aggregate) As In Hardstanding,Path, Flooring Surface Finished Even & Smooth Using Extra Cement Complete All As Specified & Directed By Engr-In-Charge. , Dismantling Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Laid, Bedded, Pointed In Mortar Etc , M&L Granite 20Mm Thick (Of Any Type) Work (Table Rubbed And Polished) In Steps, Jambs, Pillars, Window Cills, Cooking Platform And Like In And Including Cement Mortar Backing Cm (1:4),15 Mm Thick, Including Molding, Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Complete All As Specified And Directed. , Dismantling Mild Steel Or Wrought Iron Work In Roof Trusses,Gratings Etc And Similar Work Complete All As Directed , M&L For Mild Steel Work In Roof Trusses,Purlins,Rafters,Wind Ties,Crane Gantries,Rails And Fastenings And Heavy Bracket Framing (Beam,Tee,Angle,Channel Or Flat Sections) Including Distance Pieces,Cleats Etc Complete All As Specified And Directed. , Dismantaling Of Plain Or Corrugated Steel Sheeting, Any Gauge, Thickness, Including Nainital Or Similar Pattern Roof Coverings Complete All As Specified & Directed. , S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strenth Of 550 Mpa As In Roof Covering / Clading To Waall , Fixed Self Tapping Screws Complete All As Specified And Directed. , S&F Pre-Painted Galvatume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strenth Of 550 Mpa As In Roof Covering / Clading To Waall , Fixed Self Tapping Screws Complete All As Specified And Directed. , S&F Galvanised, Corrugated 0.63Mm Thick Mild Steel Sheeting With Two Corrugations Side Lap, Fixed With L-Type Or J-Type Or Cranked Hook Bolts, With Bitumen Washer / Screws Complete All As Specified And Directed. , All Same As Per Item No. 37 Above But Except Sheeting (Any Thickness) Complete All As Specified And Directed . ( Note :- Old Sheet Shall Be Obtaind From Item No - 34 Above) , S&F Plain, Galvanised, 0.63Mm Mild Steel Sheeting, In Ridges, Hips, Valley Gutters, Drip And Straight Flashings (Length And Girth As Fixed) With Grade Of Zinc Coating 275 Fixed With L-Type Or J-Type Or Cranked Hook Bolts, With Bitumen Washer / Screws In Normal/Nainital Pattern Complete All As Specified And Directed. , All Same As Per Item No. 39 Above But Except Sheeting (Any Thickness) Complete All As Specified And Directed . ( Note :- Old Sheet Shall Be Obtaind From Item No - 34 Above) , Dismantling Of Wall And Ceiling Boards (Fiber, Pulp, Insulation Etc,) Or Insulation Boards/Slabs/Blankets, Any Thickness Including Cover Fillet Complete All As Specified And Directed. , S & F For Powder Coated Aluminium Anodised Snap Grid System Of Grid Size 600 X 600 Mm Fixed To Walls With Rawl Plugs And Screws And Hang To Roof Members With 2 Mm Dia Gi Wire Comprising Of The Main Tee 28X24x3mm Thick, Cross Tee 28X24x3mm Thick And Wall Angle 24X24x3mm Thick Sections Complete All As Specified And Directed:- , S & F 4 Mm Thick Everest Designer Ceiling (E-Board Classic) Board / Tiles For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Gi/Aluminium Snap Grid As In Ceiling With And Including Dusting Of Surface And Applying Two Coats Of Oil Bond Distemper Over A Coat Of Primer Complete All As Specified And Directed , S & F In Repairs 6Mm Thick Decorative Pvc Sheet Hollow (Design Approved By Ge) For Insulation And Acoustic Purpose On Wall Surface, Screw To Timber Frame Work For Levelling Of Wall As Reqd, Including With Panelling To Vertical Surfaces, Fixed With Rawl Plug And Screws Complete All As Specified And Directed , Dismantling Of Boarding , Any Description Fixed In Any Position Like Wall ,Wooden Flooring And Ceiling Boards (Fiber, Pulp, Insulation Etc,) Or Insulation Boards/Slabs/Blankets, Any Thickness Including Cover Fillet Complete All As Specified And Directed. , S&F For 8Mm Thick, Wooden Pieces, Machine Presured One Side Laminated And Other Side Balancing Green, As In Parquet Flooring With And Including Necessary Padding As Soft Wool Graded Type As Required At Site, Fixed With Adhesive As Per Manufacturers Instructions Including Taking Down Old Wooden Flooring With Or Without Plywood Complete All As Specified And Directed. , -Ditto- All As Per Item No. 47 Above But Except Material. , M&L For 12 Mm Thick Plywood, Grade Bwr, Type Bb, Number Of Ply 7 Nos Fixed With Screws To Timber Frame Work Complete All As Specified And Directed , S & F Second Class Hardwood 25 Mm Boarding Plain One Side With Butt Joint Fixed With Nails In Any Situation Complete All As Specified And Directed. , M/L For 0.90 Mm Thick Decorative Laminate Type 1 Of Surface Finish,Colour And Pattern As Approved, Fixed With Approved Adhesive As Per ManufacturerS Instructions Complete All As Specified And Directed , Dismatling Timber Scantling 40 Sqcm And Above In Any Position ,Unframed Work Complete All As Specified And Directed , M&L 2Nd Class Hard Wood As In Scantling Clean Sawn As In Floor/Roof/Truss/Purlin & Similar Work Of Any Description In Framed Work Complete All As Specified And Directed. , Taking Down Wooden Chowkhat Or Frame Area Not Exc 1.5 Sqm Each With Shutter (Without Taking Off Shutter From Frame) As Directed. , Taking Down Wooden Chowkhat Or Frame Area Exc 1.5 Sqm And Not Exc 4 Sqm Each With Shutter (Without Taking Off Shutter From Frame) As Directed. , Taking Down Of Shutters Of Any Description Not Exc 1.0 Sqm Each And Resecuring Or Easing And Adjusting With Refixing In Same Opening With Using Of Necessary Arrengements Complete All As Specified And Directed. , Taking Down Of Shutters Of Any Description Exc 1.0 Sqm But Not Exc 2.0 Sqm Each And Resecuring Or Easing And Adjusting With Refixing In Same Opening With Using Of Necessary Arrengements Complete All As Specified And Directed. , Taking Down Shutters ( Per Leaf ) Of Any Description Not Exc 1 Sqm Each Complete All As Specified And Directed. , Taking Down Shutters ( Per Leaf ) Of Any Description Exc 1 Sqm But Not Exc 2 Sqm Each Complete All As Specified And Directed. , S & F 2Nd Class Hard Wood Plain Solid Straight Chowkhats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered Put Together With Glue Pinned At Joints, And Making Good With Existing Surface As Complete As Specified And Directed. , S & F 35 Mm Thick Second Class Hard Wood Glazed And Skeleton Door Shutters, Open Rebated And Prepared To Receive Gauze Without Sash Bars, Edges Of Framing Plain Fitted With Cut And Mitred Beads For Securing Wire Mesh Or Glass, Size Of Members Of Shutter As Specified In Ssr Pt-I Sec-8 Clause 8.24(A) Fitted To Chowkats, Complete As Specified And Directed. , S&F 35 Mm Thick Second Class Hardwood Plain, Framed, Panelled Shutters (Any Number Of Panels), With Panels Of Timber Flat On Both Sides (Feather Edged), Or Of Veneered Particle Board Medium Density, Wood Particle Board With Commercial Face Veneers: Supplied And Fitted To Chowkats Complete All As Specified & Directed. , S&F 30 Mm Thick Flush Shutters Solid Core Construction With Block Board Core And Plywood Face Panels Commercial Type On Both Sides. , S&F 30 Mm Thick Second Class Hard Wood Glazed And Skelton Window And Ventilators Shutters Open Rebated And Prepaired To Received Glass Gauge Etc Divided Into Square With Sash Bar Edges Of Framing Plain Chamfered Or Rounded Fitted With Cut And Mittered Beads For Sequring Glass Gauge Etc , Size Of Members Of Shutters As Specified In Mes Ssr -I Section 8 Clause 8.24 (B) Complete All As Spcified And Directed , M&L Mild Steel Work In Framed Work Such As Grills, Gratings, Guard Bars Etc., With Ends Of Bars Shouldered And/ Or Riveted, Or Forged Into Spikes, And Similar Work Confirming To Fe 290.Gde-E-165, Complete All As Specified And Directed. , Hacking Out Old Broken Glass (Any Thickness, Size, Quality Or Description) From Wooden Frames Or Stone, Concrete Or Brick Surrounds, Glazed With Putty Or Fixed With Beads As Directed. , S&F Sheet Glass Ordinary Quality & Glazing With Wooden Bead/Oil Putty In Square N.Exc 0.5 Sqm In Each Panel 3 Mm Thick Complete All As Per Specified And Directed. , S & F 3 Mm Thick Figured Glass, Pin Headed Type And Glazing With Oil Putty In Squares Not Exceeding 0.5 Sqm In Each Pane Complete As Specified And Directed. , S&F Sheet Glass Ordinary Quality & Glazing With Wooden Bead/Oil Putty In Square N.Exc 0.5 Sqm In Each Panel 5.5 Mm Thick Complete All As Per Specified And Directed. , S & F Galvanized Mild Steel Wire Cloth, 0.56 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18 Mm And Fixed With Tinned Stacks, Or Galvanized Wire Staples, Complete All As Specified And Directed. , Supply And Fixing 75 Mm Butt Hinges Medium Weight Cold Rolled Mild Steel Isi Marked Fixed With Wooden Screws Complete As Specified And Directed. , Supply And Fixing 100 Mm Butt Hinges Medium Weight Cold Rolled Mild Steel Isi Marked Fixed With Wooden Screws Complete As Specified And Directed. , Supply And Fixing 100 Mm Mild Steel Pressed Handles, Oval Type, Stove Enamelled Black And Fixed With Wooden Screws, Complete As Specified And Directed. , Supply And Fixing 150 Mm Mild Steel Pressed Handles, Oval Type, Stove Enamelled Black And Fixed With Wooden Screws, Complete As Specified And Directed. , M&L For Mild Steel Barrel Tower Bolts Stove Enameled Black, With Bright Bolt Length Of Bolt 100 Mm (Isi Marked) Fixed Complete Fixed With Screws,Complete As Specified And Directed. , M&L For Mild Steel Barrel Tower Bolts Stove Enameled Black, With Bright Bolt Length Of Bolt 150 Mm (Isi Marked) Fixed Complete Fixed With Screws,Complete As Specified And Directed. , Supply And Fixing Mild Steel Sliding Door Bolt Clip Type (Isi Marked) Stove Enameled Black With Bright Bolt Not Less Than 12 Mm Dia With And Including A Minimum Of 6 Bolts, Length Of Bolt 250 Mm And Fixed With Mild Steel Wood Screws All As Specified And Directed , S&F In Repair Butt Hinges, Medium Weight, Cold Rolled Mild Steel, 75Mm Size Complete All As Specified And As Directed , S&F In Repair Butt Hinges, Medium Weight, Cold Rolled Mild Steel, 100Mm Size Complete All As Specified And As Directed , S&F In Repair 100 Mm Mild Steel Pressed Handles, Oval Type, Stove Enamelled Black And Fixed With Wooden Screws, Complete As Specified And Directed. , S&F In Repair 150 Mm Mild Steel Pressed Handles, Oval Type, Stove Enamelled Black And Fixed With Wooden Screws, Complete As Specified And Directed. , S&F In Repair Mild Steel Barrel Tower Bolts Stove Enameled Black, With Bright Bolt Length Of Bolt 100 Mm (Isi Marked) Fixed Complete Fixed With Screws,Complete As Specified And Directed. , S&F In Repair Mild Steel Barrel Tower Bolts Stove Enameled Black, With Bright Bolt Length Of Bolt 150 Mm (Isi Marked) Fixed Complete Fixed With Screws,Complete As Specified And Directed. , S&F In Repair Mild Steel Sliding Door Bolt Clip Type (Isi Marked) Stove Enameled Black With Bright Bolt Not Less Than 12 Mm Dia With And Including A Minimum Of 6 Bolts, Length Of Bolt 250 Mm And Fixed With Mild Steel Wood Screws All As Specified And Directed , S&F In Repair Mild Steel 300Mm Ordinary Rat Tail Rod Pattern Spring Including Roller And Roller Plate Complete Complete All As Specified & Directed. , S&F In Repair 150Mm ,Floor Door Stopper Of Aluminium Alloy Body And Tongue, Anodised, With Hard Drawn Steel Spring, Fixed In Floor Complete Complete All As Specified & Directed. , M&L Preparation Of New Or Previously Untreated Wood And Wood Based Surfaces Of Any Description, Not Otherwise Described, Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint (Ordinary Tint) Over A Coat Of Pink Primer Complete All As Specified And Directed. , M&L Preparation Of New Or Previously Untreated Steel Surfaces Of Any Description, Over 10 Cm Width Or Girth, Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint (Ordinary Tint) Over A Coat Of Red Oxide Primer, Complete All As Specified And Directed. , S&F In Repair 25 Mm Dia Curtain Rod/Harrison Rails,Mild Steel, Chromium Plated Fancy Type Fixed With End Brackets, Stops ,Rollers & All Connected Accessories Complete All As Specified And Directed. , Disconnecting Existing Water Tank Setting Aside ( Or Lowering If Required ) For Repairs Cleaning Etc And Hoisting If Required Reconnecting And Re-Fixing In Position Including Cleaning And Removing All Scale And Dirt Etc From Tanks And From Mouths Of Circulating Pipes Etc Cap Exc 250 Ltr & N. Exc 500 Ltrs, Complete All As Specified And As Directed By Engr-In-Charge. , Disconnecting Existing Water Tank Setting Aside ( Or Lowering If Required ) For Repairs Cleaning Etc And Hoisting If Required Reconnecting And Re-Fixing In Position Including Cleaning And Removing All Scale And Dirt Etc From Tanks And From Mouths Of Circulating Pipes Etc Cap Exc 500 Ltr & N. Exc 1000 Ltrs, Complete All As Specified And As Directed By Engr-In-Charge. , Dismantling Pvc Water Tanks And Removing From Site Capacity For Exc 250 Ltrs But N. Exc 500 Ltrs Complete All As Specified And As Directed. , Dismantling Pvc Water Tanks And Removing From Site Capacity For Exc 500 Ltrs But N. Exc 1000 Ltrs Complete All As Specified And As Directed. , M&L For Rotational Moulded Polyethylene Water Storage Tank 250 Ltrs Capacity Double Layered Cylindrical Vertical With Closed Top Hoisted And Fixed In Position Including Fittings All As Specified And As Directed. , M&L For Rotational Moulded Polyethylene Water Storage Tank 500 Ltrs Capacity Double Layered Cylindrical Vertical With Closed Top Hoisted And Fixed In Position Including Fittings All As Specified And As Directed. , M&L For Rotational Moulded Polyethylene Water Storage Tank 1000 Ltrs Capacity Double Layered Cylindrical Vertical With Closed Top Hoisted And Fixed In Position Including Fittings All As Specified And As Directed. , S&F 20Mm Bore Ball Valve, High Pressure With Epoxy Coated Aluminium Rod And High Density Plastic Vavle Screwed For Iron Pipe And Fixed Of 20Mm Dia (Min Wt 210 Grms) Complete All As Specified And Directed. , S&F In Repair 15Mm Bore Ball Valve/Float Valve, High Pressure With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed Of 15Mm Dia (Min Wt 142 Grms) Complete All As Specified And Directed. , S&F In Repair 20Mm Bore Ball Valve/Float Valve, High Pressure With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed Of 20Mm Dia (Min Wt 210 Grms) Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Tubing And Connections, Complete All As Specified And As Directed , Taking Up Or Down 20 Mm Bore Steel Tubing And Connections, Complete All As Specified And As Directed By Engr-In-Charge. , Supply And Fix 15 Mm Bore Galvanized Steel Water Tubing, Medium Grade Including Necessary Fittings Such As Gi Bends, Tee, Union Etc Fixed On Wall / Floor Complete And Connecting To Water Supply Pipe Line All As Specified And As Directed By Engineer-In-Charge. , Supply And Fix 20 Mm Bore Galvanized Steel Water Tubing, Medium Grade Including Necessary Fittings Such As Gi Bends, Tee, Union Etc Fixed On Wall / Floor Complete And Connecting To Water Supply Pipe Line All As Specified And As Directed By Engineer-In-Charge. , Supply And Fix In Repair White Vitreous China Squatting Pan ‘Orissa Pattern Of Size 580 Mm X 450 Mm White With Integral Foot Rests With ‘P Or ‘S Trap, Front Or Back Inlet Including All Connection And Provision Of Lime Concrete Base Complete All As Specified And As Directed.. , S&F In Repair Vitreous China Wash Down Water Closet Pan (Padestal Pattern) With Seat Cover (Excluding Fixing Bolts, Flushing Cistern And Flush Pipe) Etc Complete All As Specified And As Directed. , S&F In Repair Flushing Cistern 10Ltr Capacity Pvc Valveless, Syphonic Action Type, Low Level, White, With Inlet, Ball Valve, Float And Handle Including Brackets Complete All As Specified & Directed. , S&F In Repair For Wash Basins, Vitreous China (Flat Back Or Angle Back Type) Size 580X450mm, Including Cutting For And Pinning In Ends Of Brackets Or Erecting Stand But Exclusive Of Fixing Of Supply And Waste Pipe , Complete All As Specified And As Directed. , S&F In Repair Single Piece Ewc Combined With Flushing Cistern, Waste Pipe, Trap, Seat Cover, Jet Spray Including All Necessary Accessories, Fittings & Bolts Complete All As Specified & Directed. Make- Jaguar Lyric Single Piece Ewc P-180 Complete All As Specified And Directed. , S&F In Repair Bathroom Tabletop Ceramic Washbasin (Size Not Less Than 500X300x125mm) Over Marble Counter And Bwr Plywood Cabinet (White) As Approved By Ge With Waste Pipe, Coupling And Fittings Complete All As Specified & Directed. Make- As Approved By Ge , S&F In Repair 15 Mm Dia Bib Tap Cast Copper Alloy, Fancy Type Chromium Plated ,With Crutch Or Butterfly Handle, Screwed Down For Iron Pipe Or For Brass Ferrule All As Directed. , S&F In Repair Fancy Type 15 Mm Dia Pillar Taps ,Cast Copper Alloy ,With Capstan Heads Chromium Plated Screwed Down High Pressure, With Or Without Letterd Hot Or Cold With Long Screwed Shanks And Fly Nuts ,Screwed For Iron Pipe And Fixed. , S&F In Repair Brass Cp Stop Valve/ Angle Valve 15 Mm Fancy Type With Long Shank And Cup Fixed. , S&F In Repair 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood & Fixed To Wooden Plugs With Cp Brass Screws & Cup Washers Complete All As Specified & Directed. , S&F In Repair Toilet Paper Holder( White) With Flat Recessed Type Stainless Steel Complete All As Specified And Directed. , S&F In Repair Plastic Water Closet Seat, Black, Closed Pattern With Flat Bottom, And Cover And Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified & Directed. , S&F In Repair Soap Dish Tray Embedded In Wall , Vitreous China White, Approximate Size 160X160x90 Mm Complete All As Specified & Directed. , S&F In Repair Pvc Connection 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified & Directed. , S&F In Repair Tubular Brass Chromium Plated Towel Rail, 20Mm Dia, D Type, 60Cm Long Between Flanges Complete All As Specified & Directed. , S&F In Repair 15Mm Bore Fancy Type Chromium Plated Central Hole Wash Basin Mixer With 450Mm Long Braided Hoses,Screwed Down High Pressure With Or Without Lettered Hot And Cold Srcrewed For Iron Pipe Complete All As Specified & Directed. Make-Jaguar Or Equivalent Approved By Ge , S&F In Repair 15Mm Bore Fancy Type Chromium Plated Wall Mixer With Provision For Overhead Shower With 115Mm Long Bend Pipe On Upper Side, Connecting Legs And Wall Flanged,Screwed Down High Pressure With Or Without Lettered Hot And Cold Srcrewed For Iron Pipe Complete All As Specified & Directed. Make- Jaguar Or Equivalent Or Approved By Ge , S&F In Repair Ptmt Nipple 15 Mm Bore Dia For Hdpe Water Tank(Min Weight-38 Gms) Complete All As Specified & Directed. , S&F In Repair Ptmt Nipple 20 Mm Bore Dia For Hdpe Water Tank(Min Weight-45 Gms) Complete All As Specified & Directed. , S&F In Repair Union Brass Of 15Mm Bore Dia To Connect Iron To Polyethylene Complete All As Specified & Directed. , S&F In Repair Union Brass Of 20Mm Bore Dia To Connect Iron To Polyethylene Complete All As Specified & Directed. , S&F In Repair Elbow/Tee Of 15 Mm Bore Dia Brass All Ends Screwed And Fixed Complete All As Specified & Directed. , S&F In Repair Elbow/Tee Of 20 Mm Bore Dia Brass All Ends Screwed And Fixed Complete All As Specified & Directed. , S&F In Repair 32 To 40 Mm Dia Pvc Waste Pipe For Wash Basin And Kitchen Sink Complete All As Specified & Directed. , Taking Up 80Mm Bore Pipes Cast Iron Water Mains (Including All Fittings), With Spigot And Socket Ends And Lead Joints Includingburning Out Joints And Recovering Lead Complete All As Specified And As Directed , S&F In Repair Pvc (Swr) Pipes 75 Mm Dia Single Socketed, In Any Length With Rubber Ring Joints, Fixed On Walls Or Floors Complete All As Specified And As Directed , S&F Pvc (Swr) Plain Bend 75 Mm Dia, Of Any Redius With Rubber Ring Joints, Complete All As Specified And As Directed , S&F Pvc (Swr) Plain Bend 110 Mm Dia, Of Any Redius With Rubber Ring Joints, Complete All As Specified And As Directed , Taking Up 100 Mm Bore Pipes Cast Iron Water Mains (Including All Fittings), With Spigot And Socket Ends And Lead Joints Includingburning Out Joints And Recovering Lead Complete All As Specified And As Directed , S&F In Repair Pvc (Swr) Pipes 110 Mm Dia Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors Complete All As Specified And As Directed , S&F 32Mm Dia Waste Fittings, Brass, Chromium Plated For Glazed Ware Sinks, Basins, Etc With Long Screwed Shanks And Fly Nuts, Flange End Bedded In Red Lead Cement And Other End Fixed. , S & F In Repairs 15 Mm Bore Fancy Type Telephonic Shower (Healthfaucet), Cast Copper Alloy, With Chromium Plated, Screwed Down High Pressure With Or Without Lettered Hot Or Cold With Lenght Not Less Than 1.0Mtr Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe/Stop Value And Fixed As Cat No 455, Make:- Prayag Or Equavalent As Approved By Ge. , M&L For 75Mm Dia Pvc Nahani Trap Or Floor Trap With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B1 Complete All As Specified And Directed. , S&F In Repair Sink With Drainage Board Made Of Stainless Steel 1Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X 460Mm Bowl Size 410Mm X 330Mm X 160Mm Complete All As Specified And Directed. , S& F Power Coated Aluminum (Minimum Thikness Of Power Coated 50 Micron ) Work For Doors Windows, Ventilators And Partition (Fixed Portion ) With Extruded Built Up Standard Tubular Section/Approriate Z Section And Other Section Of Approved Make Confirming To Is 733 And Is 1285 , Fixing With Dash Fasteners Of Required Dia And Size, Inc.Necessary Filling Up The Gaps At Junction , I.E. At Top , Bottom And Sides With Required Epdm Rubber/Neoprene Gasket Etc Aluminium Sections Shall Be Smooth And Rust Free Straight , Mitered And Jointed Mechnicallly Where Ever Required Incl. Cleat Angle . Aluminium Snap Beding For Glazing/Paneling , C.P Brass / Stainless Steel Screws , All Complete As Per Architectural Drg And Direction Engr - In Charge , S &F Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/Neoprene Gasket Required (Fittings Shall Be Paid For Separately) With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.P. Brass/ Stainless Steel Screws All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. , S&F In Reparis 15Mm Bore Bib Tap Standard Of Ptmt Any Colour High Pressure Screwed For Iron Pipe And Fixed With And Including Wall Flange (Minimum Weight 15Mm-90Gms)Complete All As Specified And As Directed (Make : Prayag Or Equivalent). , S&F Aluminium Die Cast Body Door Closer Hydraulically Regulated Designation No,2 Universal Type Suitable For Door Shutter Of 701 To 850Mm Width And Of Weight Between 36 To 60 Kg Isi Marked Complete. , S&F In Repair Vitreous China Urinal, Half Stall Type, White With Waste Pipe And Cp Brass Spreader Complete Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plug With And Including 60Mm Long Brass Screws, Pointing Around Urinal Back In Cement; Flush Pipe, Grating And Union For Discharge Pipe Including Cp Urinal Spreader For Fixing With 15 Mm Dia Pipe Complete All As Specified. , Supply Only Water Tank Cover For Tanks Of Size 500 Ltr Or 1000 Ltrs Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttarakhand View Result →
18.
Agriculture #11175867 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Clearing And Grubbing Road Land Clearing And Grubbing Road Land Including Uprooting Wild Vegetation, Grass, Bushes, Shrubs, Saplings And Trees Of Girth Upto 300 Mm, Removal Of Stumps Of Such Trees Cut Earlier And Disposal Of Unserviceable Materials And Stacking Of Serviceable Material To Be Used Or Auctioned, Upto A Lead Of 1000 M Including Removal And Disposal Of Top Organic Soil Not Exceeding 150 Mm In Thickness As Per Morth Specification Clause 201. By Mechanical Means In Area Of Thorny Jungle , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 50 M As Per Morth Specification Clause 305.3 , Carriage Of Earth, Sand, Lime, Morrum Manure Or Sludge For 5 Km. , Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. , Dismantling Stone Slab/ Terrazo Chip Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. , Carriage Of Building Rubbish Stone Metal (Grit And Ballast Etc.) Up To 50 Mtr Lead , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786) Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Providing And Laying Damp-Proof Course With Cement Concrete Grade M-150 (1 : 2 : 4) Mortar Prepared With 1% Solution Of Water-Proof Compound Complete As Per Specification 50Mm Thick. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Random Rubble Dry Stone Kharanja Under Floor. , Supply And Installation Of Multi Rib Proofing/Cladding Sheet Manufacture Out Of 0.50Mm Tct (Total Coated Thickness) High Tensile Zinc Aluminum Alloy Coated Galvalume Steel (As Per 150Gsm Zinc Aluminum Coated 550Mpa Tuekd Strength) Confirming To Is: 1397/Astm A-792 Sheet To Have Wide Pens 30Mm High Nb At 250 Centre And Centre Width Of 1020Mm Sheets Be Casted With Regular Modified Polyster System On A Continuous With Line On Centre For Face And With A Polyster Coating Respectively Sheet Shall Have Proportionality With Siphoned Plate Made To Prevent Leakage Sheet Shall Be Fixed By More Of Sell Drilling Lift Tapping Hot Dip Zinc Coated Hox Head Fasterner Of Size 12X14x55mm Long. The Sheet Shall Be Supplied In Cost One Length And For A Minimum Up To 12Mts With All Scaffolding. , Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu /Jalore (Red/Choclate/Black/ Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joints Etc. Complete Fine Finish : 12 Mm Thick . , Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) , Repair Of Door, Window Shutters Including Cost Of Material And Labour For Change Of Damaged : Style/Rail Of Teak Wood 30Mm Thick/ Aluminium Section 4Wide , Renewing Glass Panes And Refixing Existing Wooden Fillets : 5Mm Thick Plain Glass Panes. , Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge Window Openable. , Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Making Khurras 450 X 450Mm With Average Minimum Thickness 50Mm Cement Concrete 1 : 2:4 Over P.V.C. Sheet 1 Mtr. X 1 Mtr. X 40Micron Finished With 12Mm Cement Plaster 1 : 3 And One Coat Of Neat Cement, Rounding Edges And Making And Finishing The Out Let Complete. , Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Whenever Required. 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm/M2 , Providing And Fixing Welded Mesh/Expanded Metal Mesh In Frame Work, Flat Iron Beading 20X3mm Including Top Cross Laps Inside And Out Sides Welding, Iron Bolts, Crews, Clips Etc. Complete (Excluding Frame Work) Of Size. Welded Mesh 25 Mmx 25 Mm X 2.1 Mm , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Charge : Profile B , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing & Fixing Mica Of Approved Make For Inner/Outer Side Of Shutters With Fevicol & Nails Complete As Per Approved By Engineer In Charge. 0.8Mm Thick Mica , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 60 Mm As Per Drawings And As Per Is 15658:2006.And Materials Conforming To Morth Specification Clause 602 With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blocks. Category B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Granular Sub-Base With Close Graded Material (Table:- 400-1) Plant Mix Method Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (Crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.E Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (As Per I.S.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[Morth Specification : Clause 401]. By Mechanical Means. For Grading-Iii Material , Dry Lean Cement Concrete Sub - Base. Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Providing And Laying Water Proofing Treatment On Roofs Of Slabs By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : , After Surface Preparation, First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. , Laying Second Layer Of Fiber Glass Cloth When The First Layer Is Still Green . Overlaps Of Joints Of Fiber Cloth Should Not Be Less Than 10 Cm . , Third Layer Of 1.5 Mm Thickness Consisting Of Slurry Of Cement @ 1.289 Kg/Sqm Mixed With Water Proffing Cement Compound @ 0.670 Kg/Sqm And Coarse Sand @ 1.289 Kg/Sqm. This Will Be Allowed To Air Cure For 4 Hours Followed By Water Curing For 48 Hours. The Entire Treatment Will Be Taken Upto 30Cm On Parapet Wall And Tucked Into Groove In Parapet All Around , Fourth And Final Layer Of Brick Tiling ‘With Cement Mortar Or Any Other Approved Protective Coarse. (Which Will Be Paid For Separately) For The Purpose Of Measurement The Entire Treated Surface Will Be Measured , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Old Work (One Or More Coats ) , Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , One Or More Coats On Old Work. , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: Old Work (One Or More Coats). , Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Prepartion Of Base With Sand Papering, Primer, Putty, Etc Complete In All Respect Including Scaffolding And Safety Provision New Work , Old Work , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meter Lead : For Thickness Of Tiles 10Mm To 25Mm. , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. 1: 3: 6 Or Richer Mix. , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately). , For Fixed Portion Anodised Aluminum (Anodised Transparent 81 Dyed To Required Shade According To Is : 1868. (Minimum Anodic Coating Of Grade Ac 15, Anodizing To Be Got Done From Approved Anodizer) , For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Anodised Aluminum (Anodised Transparent 81 Dyed To Required Shade According To Is : 1868. (Minimum Anodic Coating Of Grade Ac 15, Anodizing To Be Got Done From Approved Anodizer) , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs/Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge. (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.) With Glass Panes Of 4.0 Mm Thickness ( Weight Not Less Than 10.0 Kg/Sqm) As Per Is : 2835. , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge. Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , P & F Soap Dish Or Tray Of Approved Quality/Make C.P. Brass , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : Size 580 Mm X 450 Mm , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : Size 630 Mm X 500 Mm Dia For Counter Top , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make :450 Mm , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P & F Kitchen & Lab. Sink Of Approved Make With C.I. Brackets Duly Painted, 40 Mm C.P. Waste Coupling, C.P. Brass Chain With Rubber Plug, 40 Mm G.I. Waste Pipe Up-To Floor Level Complete Including Cutting And Making Good The Wall & Floor : 1.0 Mm Thick Stainless Steel Aisi -304 & Is 13983-1994 Kitchen Sink Of Approved Make As Per Engineer-In-Charge With Large Waste Coupling. 45 X 20 X 8 20X16x8 (With Drain Board) , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- , Size 230 X110 X150 Cm.(For 20 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F Grating Of Approved Quality/Make: Stainless Steel Sheet Size 125Mm Dia. Heavy Quality Of Approved Make , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) 20Mm Nominal Size , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20Mm Nominal Size , 25 Mm Nominal Size , 32Mm Nominal Size , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: C.P. Brass Bib Cock,15Mm Nominal Bore. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings, This Included Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement , Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. (External Work). , 25 Mm Nominal Size , 32Mm Nominal Size , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: , Coupler (Socket) , 110Mm Dia , Plain Tee , 110Mm Dia , Bend 87 .5 , 110Mm Dia , Pipe Clip , 110Mm Dia , Providing And Fixing Superior Quality Pvc Tank Cover Complete As Per Approved By Engineer In Charge , Above 500 Lt. Capacity , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: , 1000 Ltr. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete : Solid Pvc (Is 2548 Marked) Grade-I White For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend As Per Is : 7231 . , Providing And Fixing Unplasticized Poly Vinyl Chloride (Upvc) Swr Pipes Type B For Sciland Waste Discharge System (Is:13592 : 1992 Marked) Of Approved Quality /Make 110 Mm Dia , Providing And Fixing Unplasticized Poly Vinyl Chloride (Upvc) Swr Pipes Fittings Type B For Sciland Waste Discharge System (Is:13592 : 1992 Marked) Of Approved Quality /Make 110Mm Dia , Coupler , Bend 87.5 Dg. , Bend 45 Dg. , Door Bend 87.5 Dg. , Single Tee , Vent Cowel
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
19.
Defence #11153966 AOC
Bids Are invited for Provision Of Shelter Parts And Other Items For Chdh Shelter Parts For Cook House And Dining Hall , Pcc Cement Is 1489 , Coarse Sand , 20Mm Aggregates , 40Mm Aggregates , Hardcore 63Mm Stone Aggegates , Pcc Solid Block 400 Into 200 Into 200Mm , Galvanised Coloured Tiles Size Of 600Mm Into 600Mm Into 910Mm , Glazed Ceramic Coloured Tiles Non Skid Of Size Of 300Mm Into 600Mm Into 9 To 10Mm Thick , Chequred Tile 250 Into 250 Into 25Mm , Mild Steel Tmt Bars 12Mm Dia , Mild Steel Tmt Bar 8Mm Dia , Drapery Curtain Rod 7 Feet Long 20Mm Dia , Drapery Curtain Rod 4 Feet Long 20Mm Dia , Bracket With Knob For Curtain Rod , Granite Stone Slab 2 Into Zero Point 60 Mtr Having 20 To 22 Thick , Wash Hand Basin With Cp Waste Coupling And Pvc Waste Pipe Along With Ms Bracket For Whb , Stainless Steel Kitchen Sink With Cp Waste Coupling And Waste Pipe Along With Angle Base Frame , Pvc Connection Pipe 450Mm Long With Both Side Neat Of 15Mm Dia , Cp Stop Cock 15Mm , Cp Bib Cock Long Body 15Mm Dia , Cp Pillar Cock 15Mm Dia , Pvc Waste Coupling 32Mm Dia , Cp Bib Cock 15Mm Dia , Pvc Waste Pipe 32Mm Dia , Staging For Water Storage Tank Of Size 1 Point 25Mm Into 1 Point 50Mm Into 1 Point 50M Into 4 Point 50Mm Height With Ms , Triple Layer Hdpe Water Storage Tank Cylinderical With Closed Top 1000 Ltrs Capacity , Tank Nipple 20Mm Dia With Both Side Check Nut And Rubber Washer Isi Maked , Pvc Float Valve 25Mm , Ppr Gate Valve 25Mm Dia , Ppr Pipe 25Mm Dia Three Layers Outer Green Uv Stabilized , Ppr Pipe 20Mm Dia Three Layers Outer Green Uv Stabilized , Ppr Pipe Union 25Mm Dia , Ppr Pipe Socket 25Mm Dia , Ppr Pipe Elbow 25Mm Dia , Ppr Pipe Tee 25Mm Dia , Ppr Reduction Tee 25 By 20Mm , Ppr Pipe Tee 20Mm , Ppr Pipe Elbow 20Mm , Ppr Reducer Elbow 25 By 20 , Ppr Pipe Tank Nipple 20Mm , Ppr Pipe Socket 20Mm , Ppr Wall Cl S 20Mm , Ppr Wall Cl S 25Mm , Ppr End Cap 25Mm , Ppr End Cap 20Mm , Ppr Socket Male Brass Threaded 20Mm , Ppr Socket Female Brass Threaded 20Mm , Ppr Elbow Male Brass Threaded 20Mm , Ppr Socket Female Brass Threaded 20Mm , Ppr Socket Female Brass Threaded 20Mm 1 By 2 Inch , 1 Hp Booster Pump With Auto Starter Mcb Dp 16 Dp Main Switch 2 Point 5 Sqmm Copper Wire 40 Mtr And Nrv Complete Set , Pvc Pipe Of 110Mm Dia 6 Mtr Long With Collar For Sewage Disposal To Septic Tank Isi Marked , Pvc Pipe Of 75Mm Dia 6 Feet Long With Collar For Air Extention Of Sewage Tank Isi Marked , Pvc Cowl 100Mm Dia For Air Extesion Pipe , Pvc S Trap 100Mm Dia Isi Marked , Pvc Elbow 100Mm Dia Isi Marked , Pvc Tee 100Mm Dia Isi Marked , Pvc Coupler 100Mm Dia Isi Marked , Pvc Bend 100Mm Dia Isi Marked , Pvc Floor Trap 75Mm Dia With Grating Isi Marked , Pvc Coupler 75Mm Dia Isi Marked , Water Proofing Compound , White Cement , Lime Unslaked Of Best Quality , Surface And Wall Mounted Led Tube Rod 15 Watt 1600 Lumens Output With Fittings Frame , Led 12W Rechargable Emergency Inverter Led Bulb Complete With Inbuilt Lion Battery , Pixel Bulb Head Fittings In Deep Drawn Aluminium Body Led L 1 Into 5 Watt , Ceiling Fan 1200Mmsweep With Regulator Confs To Isi Marked And Complete Fan Hooks And Ms Cl S , Pedestal Fan 400Mm Sweep Isi Marked , Exhaust Fan 300Mm Sweep Isi Marked , Pvc Insulated Unarmoured Standrad Conductor Cable Of Size 10 Sqmm Conf To Isi Marked , Porcelain Insulating Hangers , Pvc Insulated Unarmoured Standrad Conductor Cable Of Size 1 Sqmm Conf To Isi Marked , Pvc Insulated Unarmoured Standrad Conductor Cable Of Size 1 Point 5 Sqmm Conf To Isi Marked , Pvc Sheathered Unarmoured Standrad Conductor Cable Of Size 1 Sqmm Conf To Isi Marked , Pvc Sheathered Unarmoured Standrad Conductor Cable Of Size 1 Point 5 Sqmm Conf To Isi Marked , Pvc Sheathered Unarmoured Standrad Conductor Cable Of Size 2 Point 5 Sqmm Conf To Isi Marked , Pvc Sheathered Unarmoured Standrad Conductor Cable Of Size 4 Sqmm Conf To Isi Marked , Modular Switch Piano Flush Type 6 240 Volts Single Pole Onre Way , Modular Switch Piano Flush Type 16 240 Volts Single Pole Onre Way , Modular Socket Outlet Multipurpose 2 By 3Pion 6 S Flush Button Type , Modular Socket Outlet Multipurpose 2 In 1 6 And 16 S , Surface Mounting Plastic Boxes Suit For Switches 12 Module Of Size 8 Inch Into 6 Inch , Surface Mounting Plastic Boxes Suit For Switches 8 Module Of Size 9 Inch Into 3 Inch , Surface Mounting Plastic Boxes Suit For Switches 6 Module Of Size 8 Inch Into 3 Inch , Surface Mounting Plastic Boxes Suit For Switches 4 Module Of Size 8 Inch Into 3 Inch , Combined Cover Plate With Frame Inner And Outer Of 12 Module , Combined Cover Plate With Frame Inner And Outer Of 8 Module , Combined Cover Plate With Frame Inner And Outer Of 6 Module , Combined Cover Plate With Frame Inner And Outer Of 4 Module , Blanking Plate For Switch Or Socket , Cealing Rose With Square Box 65 Into 50Mm 2 To 3 Terminals , Pvc Flexible Nibbed Pipe 20Mm Dia , Pvc Conduct Pipe 20Mm Dia Isi Marked , Pvc Elbow For 20Mm Dia Pvc Conduit Pipe , Pvc Space Bar Saddies For 20Mm Dia Pvc Pipe , Pvc Coupler For 20Mm Dia Pvc Pipe , Pvc Tee For 20Mm Dia Pvc Pipe , Pvc Socket For Casing Capping 25Mm Conf To Is , Pvc Coupler For 25Mm Casing Capping , Pvc Tee For 25Mm For Casing Capping , Pvc Sockets For 25Mm Casing Capping , Pvc Elbow For 25Mm Casing Capping , Pvc Corner Bend For 25Mm Casing Capping , Pvc Casing Capping 32Mm Wide 2 Mm Thick , Pvc Coupler For 32Mm Casing Capping , Pvc Tee For Casing Capping 32Mm Conf To Is , Pvc Elbow For Casing Capping 32Mm Conf To Is , Pvc Corner Bend For Casing Capping 32Mm Conf To Is , Pvc Junction Box Two Way 20Mm Conf To Is , Pvc Junction Box Three Way 20Mm Conf To Is , Pvc Junction Box Four Way 20Mm Conf To Is , Pvc Junction Linker 75 Into 75 Mm , House Service Bracket Hook Type Complete With 3Mm Long Gi Pipe 40Mm Dia , Mcb Distribution Box 8 Way Conf To Is , Mcb 8 240 Volt Breaking Capacity 10 Ka Conf Top Iec 60898 , Mcb 16 240 Volt Breaking Capacity 10 Ka Conf Top Iec 60898 , Mcb 40 240 Volt Breaking Capacity 10 Ka Conf Top Iec 60898 , Insulation Tape 19Mm Width 25 Mtr Long , No 8 Into 19 Csk Screw Full Threaded , No 8 Into 32 Csk Screw Full Threaded , No 8 Into 50 Csk Screw Full Threaded , No 8 Into 75 Bolt And Nuts Full Threaded , Geyser 25 Ltr Capacity With Isi Marked Incl Bracket With All Fitting Accessories , Pvc Connection Pipe 450Mm Long With Both Side Neat Of 15Mm Dia , Earthing Set Complete With All Fitting Accessoried As Per Appx I Of Ts , Chair Writing As Per Ts Given In Appx C , Writing Table As Per Ts Given In Appx C , Dining Chair As Per Ts Given In Appx C , Dining Table As Per Ts Given In Appx C , Stainless Steel Table As Per Ts Given In Appx C , Water Dispenser As Per Ts Given In Appx C , Powder Based Fire Extinghuisher As Per Ts Given In Appx C , Store Rack As Per Ts Given In Appx D Total Quantity : 8630
Contract Date: Ref. Documents Contract Value : 54.32 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
20.
Defence #11117617 AOC
Tender For Provision Of Training Shed And Pt Shed At Varanasi; Design, fabrication, supply and erecting, Pre-engineered building steel structure/LGSF made from 345 Mpa high strength Hot rolled paletes and factory produced zincalume cold rolled light gauge steel zincalume frame (1 mm BMT)for provision oftraining and PT Sheds of size 72 metre x 18 metre x7.95 metre height from FFL to bottom of truss using 0.45 mm base metal thickness, pre-painted 0.50 mm corrugated galvalume aluminium zinc coating (AZ-150 GSM) aluminium zinc alloy coated colour having tensile strength of 550Mpa as in roofingfixed with self tapping screws including S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.60 mm thick (AZ not less than 150) of colour having tensile strength of 550Mpa as in ridge/valley gutter roof covering/cladding to wall fixed with self tapping screws, (factory made valley gutter, shape and size directed by Engineer-in Charge including supply of bolts, gutter bolts, screws, washer, pipe nails distance pieces, plug, holder bats for pipe and all jointing materials, down take pipe, downspout pipe and metal clamp of appropriate size and shape and LGSF structure with brick work in CM 1:4 onas per mentioned in architectural drawing all as specified with following design parameters all as specified and vetted design and drawing by any IIT/NIT and approved by Chief Engineer Lucknow Zone with permanent specification complete all as specified and as shown on drawing:-(i) Frame type Pre-Engineered Building (ii) Size of training and PT shed as perarchitectural drawing (iii) LGSF structure with 1 mm to 2.5 mm thick(iv) Anti-corrosion treatment and painting as per IS -1477 Part 1 & 2 .(v) PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate including form work in base of footing.(vi)RCC work M-30 in footing, plinth beam & Stair case/steps as per approved mix design and as per IS:9103(vii)All necessary civil works for setting for super structure layout, excavation, back filling, removal of surplus soil, RCC foundation/footing, plinth beam, RCC sitting step with granite finish including bull nosing finish & Stainless steel railing complete.Note : (i) Design parameters of PEB structure is attached as appendix ‘A’ (ii) Following items mentioned under srl no 1.01 to1.13 here-in after shall also be included in lump sum rate quoted against Srl item No 1 of BOQ. 2 Site clearance/site developments 3 Anti termite treatment 4 All primary structural components should be confirmed to IS: 2062 E-350 BR, Having a minimum tensile strength of 490 MPs and pass physical & Chemical tests stipulates therein 5 Purlins and side girt membersshall be made from cold Formed Sections, Confirming to IS : 811, having a minimum tensile strength of 345 MPs. The sheets used for cold forming sections shall confirm to IS : 1079, 2009 quality HR3 6 Permanently colour coated high tensile steel sheet havingminimum base metal thickness of 0.45mm (i.e excluding Aluminium -Zinc/galvanizing & colour coating thickness) & minimum Yield strength of 550 Mpa, coated with 55% Al-Zn alloy @ 150 g/Sqm as per ASTM A792M; Color coated with total minimum thickness of 40 microns (nominal) comprising of Silicon, Modified polyester (SMP with silicon content of 30% minimum) paint or super Polyester paint of minimum 20 microns (nominal) Dry Film Thickness (DFT) on exposed side over 5 microns (nominal) primer coat and 10 microns (nominal) approved colour Epoxy paint on other side over 5 microns (nominal) primer coat as per ASTM A755M 7 Kota stone flooring shall be 18 to 20 mm thick machine cut and polished at site after fixing (Mirror polish/granite polish). Size of Kota stone slabs used in floors shall be not less than 500 mm x 500mm.Kota stone slab shall be laid over 20mm thick screed in CM (1:6) over 100 mm thick PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate over rammed earth. Jointing shall be with grey cement mixed with pigment to match the shade of Kota stone slab. The floor shallachieve mirror finish surface. 8 75 mm thick PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as inplinth protection & Saucer drain. Plinth protection surface finishedeven and smooth without using extra cement of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) 9 Stainless steelrailingwith SS hand rail pipes grade 304 as perarchitectural drawing shall be provided. 10 10 to12 mm thick ready mix plaster on internal surface and external surface of wall. 11 Preparation of newly plaster surface of wall and applying two coats of synthetic enamel paint over a coat of primer on internal and external surface of wall. 12 Ramp provided same as per flooring specification 13 PAINTING SCHEME FOR STRUCTURAL STEEL WORK:(a) Soap paint :- One coat of inorganic zinc silicate primer-75 microns(b) Soap paint :- One coat of polyurethane paint -30 microns(c) Site paint :- One coat of polyurethane paint- 30 microns (after erection & fixing work) 14 Applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer on other than structural steel surface 15 Design, fabrication, supply and erecting, Pre-engineered building steel structure/LGSF made from 345 Mpa high strength Hot rolled paletes and factory produced zincalume cold rolled light gauge steel zincalume frame (1 mm BMT)for provision oftraining and PT Sheds of size 36 metre x 12 metre x 7.95 metre heightfrom FFL to bottom of trussusing 0.45 mm base metal thickness, pre-painted 0.50 mm corrugated galvalume aluminium zinc coating (AZ-150 GSM) aluminium zinc alloy coated colour having tensile strength of 550Mpa as in roofingfixed with self tapping screws including S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.60 mm thick (AZ not less than 150) of colour having tensile strength of 550Mpa as in ridge/valley gutter roof covering/cladding to wall fixed with self tapping screws, (factory made valley gutter, shape and size directed by Engineer-in Charge including supply of bolts, gutter bolts, screws, washer, pipe nails distance pieces, plug, holder bats for pipe and all jointing materials, down take pipe, downspout pipe and metal clamp of appropriate size and shape and LGSF structure with brick work in CM 1:4 onas per mentioned in architectural drawing all as specified with following design parameters all as specified and vetted design and drawing by any IIT/NIT and approved by Chief Engineer Lucknow Zone with permanent specification complete all as specified and as shown on drawing:-(i) Frame type Pre-Engineered Building (ii) Size of training and PT shed as perarchitectural drawing (iii) LGSF structure with 1 mm to 2.5 mm thick(iv) Anti-corrosion treatment and painting as per IS -1477 Part 1 & 2 .(v) PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate including form work in base of footing.(vi)RCC work M-30 in footing, plinth beam & Stair case/steps as per approved mix design and as per IS:9103(vii)All necessary civil works for setting for super structure layout, excavation, back filling, removal of surplus soil, RCC foundation/footing, plinth beam, RCC sitting step with granite finish including bull nosing finish & Stainless steel railing complete.Note : (i) Design parameters of PEB structure is attached as appendix ‘A’ (ii) Following items mentioned under srl no 2.01 to2.13 here-in after shall also be included in lump sum rate quoted against Srl item No 2 of BOQ. 16 Site clearance/site developments 17 Anti termite treatment 18 All primary structural components should be confirmed to IS: 2062 E-350 BR, Having a minimum tensile strength of 490 MPs and pass physical & Chemical tests stipulates therein 19 Purlins and side girt membersshall be made from cold Formed Sections, Confirming to IS : 811, having a minimum tensile strength of 345 MPs. The sheets used for cold forming sections shall confirm to IS : 1079, 2009 quality HR3 20 Permanently colour coated high tensile steel sheet havingminimum base metal thickness of 0.45mm (i.e excluding Aluminium -Zinc/galvanizing & colour coating thickness) & minimum Yield strength of 550 Mpa, coated with 55% Al-Zn alloy @ 150 g/Sqm as per ASTM A792M; Color coated with total minimum thickness of 40 microns (nominal) comprising of Silicon, Modified polyester (SMP with silicon content of 30% minimum) paint or super Polyester paint of minimum 20 microns (nominal) Dry Film Thickness (DFT) on exposed side over 5 microns (nominal) primer coat and 10 microns (nominal) approved colour Epoxy paint on other side over 5 microns (nominal) primer coat as per ASTM A755M 21 Kota stone flooring shall be 18 to 20 mm thick machine cut and polished at site after fixing (Mirror polish/granite polish). Size of Kota stone slabs used in floors shall be not less than 500 mm x 500mm.Kota stone slab shall be laid over 20mm thick screed in CM (1:6) over 100 mm thick PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate over rammed earth. Jointing shall be with grey cement mixed with pigment to match the shade of Kota stone slab. The floor shallachieve mirror finish surface. 22 75 mm thick PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as inplinth protection & Saucer drain. Plinth protection surface finishedeven and smooth without using extra cement of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) 23 Stainless steelrailingwith SS hand rail pipes grade 304 as perarchitectural drawing shall be provided. 24 10 to12 mm thick ready mix plaster on internal surface and external surface of wall. 25 Preparation of newly plaster surface of wall and applying two coats of synthetic enamel paint over a coat of primer on internal and external surface of wall. 26 Ramp provided same as per flooring specification 27 PAINTING SCHEME FOR STRUCTURAL STEEL WORK:(a) Soap paint :- One coat of inorganic zinc silicate primer-75 microns(b) Soap paint :- One coat of polyurethane paint -30 microns(c) Site paint :- One coat of polyurethane paint- 30 microns (after erection & fixing work) 28 Applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer on other than structural steel surface 29 INTERNAL ELECTRIFICATIONM&L for point wiring completeforOne light/Fan/Exhaust Fan/Bell point/ Bldg Security Light / Industrial wall mounting fancontrolled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 Sqmm(nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 25 mm dia non metalic PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof / floor slab and ceiling, pressed GI concealed terminal modular boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including suitable cover plate of any module including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :-(i) In case of roof/ceiling, heavy duty PVC pipe not less than 25 mm dia shall be used without any extra cost.(ii) Height of socket should be 1.2m above from FFL(iii) Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost. 30 M&L for Point wiring completeforone 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insualted and unsheathed FRLSH CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 25 mm dia non metalic PVC conduit medium grade concealed in wall / roof / floor slab and ceiling, pressed GI concealed terminal modular boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :-(i)In case of roof/ceiling, heavy duty PVC pipe not less than 25 mm dia shall be used without any extra cost.(ii) Height of socket should be 1.2m above from FFL 31 M&L forPoint wiring completefor power point controlled by oneswitch with PVC insualted and unsheathed FRLSH cable 2.5 Sqmm(nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 25 mm dia non metalic PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /wall/ floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 2.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :- In case of roof/ceiling, heavy duty PVC pipe not less than 25 mm dia shall be used without any extra cost.One circuit controlled by max one points only. 32 S&F Switch piano, flush type 5 Amps single pole, one way complete all as specified and directed. 33 S&F Socket outlet, flush type 2 in 1, 5 pin, 6 Amps, multi-purpose complete all as speci-fied and directed. 34 S&F Switch piano, flush type single pole, one way 16 Amps complete all as specified and directed. 35 S&F Socket outlet, flush type 2 in 1, 5 pin, 5 and 16 Amps, multipurpose complete all as specified and directed. 36 S&F ceiling rose two to three terminal, complete all as specified and directed. 37 S&F BLDC type air circular wall mounting fan 750mm Sweep, single phase 230 V AC, 1440 RPM, air delivery CMM, power consumption 250 watt, with string, 3 speed choice colour mate, 5 star rating & ISI marked alongwith complete accessories and connecting up the fan to ceiling rose incl PVC insulated 3 core 23/0.0076 copper cable & suitable size of flexible cord with plug top from ceiling rose to wall mounted fan arrangement on pillar / wall is deemed under quoted item rate, complete all as specified and directed 38 S & FLED wide beam optics High Bay Light 100 Wdaylight 150 lum/Wwith PDC housingsuitable for ceiling (surface/suspended) rated aluminium housing indoor type with all fixing arrangement, complete all as specified and directed. 39 S&F LED Building security light fitting 35 Watt with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <20 W (35W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers, complete all as specified and directed. 40 S & F MCB DB vertical type 4-way VTPN sheet metal enclosures 415 V with 200 Amp fully insulatedstandard copper Bushbar for each phase & sourrounded with neutral Bars & two common neutral bar, two earth bar incl cable ties fo cable management suitable for housing MCCB/TPN 415 V as incommer IP-54 protection with metal doors all enclosed on standard steel sheet flush mounted type double door factory fabricated complete without MCB & MCCB but with enclosure blank plate, complete all as specified and directed. 41 Supply and fixing MCB DB single pole pole with neutral sheet metal enclosure double door type, 240 volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standardsteel sheet flush mounting type factory fabricated powder coated complete without MCB and with enclosure blank plates for unused way suitable for 12- way ISI marked, complete all as specified and directed. 42 Supply and fixing MCB DB single pole pole with neutral sheet metal enclosure double door type, 240 volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standardsteel sheet flush mounting type factory fabricated powder coated complete withoutMCB and with enclosure blank plates for unused way suitable for 8- way ISI marked, complete all as specified and directed. 43 S&F MCB SPN 32 Amps B series, 10 KA-240 Volts, AC ISI marked, complete all as specified and directed. 44 S&F MCB single pole 6 to 32 Amp rating C Series,10 KA240 Volts, AC50 Hz , ISI marked, complete all as specified and directed. 45 S&F MCCB 415 Volts AC, with 100 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCBand with enclosure blank plates for unused way suitable for 4 way, complete all as specified and directed. 46 M&L for submain wiring with two single core 4 sqmm copper conductor FRLSH, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 25 mm dia medium grade ISI marked concealed in wallsurface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly, complete all as specified and directed.Note:- Two single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit. 47 M&L Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round baras in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.(ii) Earthing wire beyond 7.5m shall be measured and paid separately. 48 B&R WorkM & L One closed side panel of ACP Sheet with framed Mild steel structure at one side of shed with the raised platform arrangement of size12m x 6m of brick work and Tile/marble flooring for Yoga / PT Shed, complete all as specified and directed. 49 M & L for Design, fabrication ,supply & erection of pre-engineered steel building incl civil works inside shed for One store Room of dimension 5 m x 5 m, complete all as specified and directed. 50 Material and Labour for 08 nos Rope Gallows made up of framed mild steel structure fixed to walls/floors with sliding arrangement which can be slided to one side when not in use with 5 ropes to be hung from each rope gallows including painting with primer, complete all as specified and directed. 51 Material and Labour for 04 nos beam bars made up of framed mild steel structure fixed to walls/ floors to be placed at one side of edge including painting with primer, complete all as specified and directed. 52 Material and Labour for 20 nos chin up bars made up of framed mild steel structure fixed to walls/ floors at 2.4m height fixed at one side of edge of shed including painting with primer, complete all as specified and directed. 53 Supply and fixing MS grill bars all around the shed, complete all as specified and directed. 54 EXTERNAL ELECTRIC SUPPLYSupply,installation and testing of factory made,CPRI Approved cubical outdoor (Kiosk) type feeder pillar box 415 volt, 4 wire, AC 50 Hz, made out of 3.15 mm thick CRCA sheet ,weatherand vermin proof powder coating finish bothside(interior & exterior) for outdoor mounting withhaving degree of protection as per IP-56 complete factory lock two earth terminal suitable cable gland for all incoming and outgoing and removable neutral link,Both Side openable double door Indicating light LED type RYB - 01 Set,Ammeter-01, Voltmeter-01, connecting strip/solid conductor brought out to cable chamber brass/copper nut, bolts/washer etc including grouting of feeder pillar box 60 cm above ground level including suitable size angle iron stand made up of65 x 65 x 6 mm welded on all the four corner embedded in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) upto 30 cm includingexcavation and earth work complete with following asseccories:-(a) copper insulatd busbar high conductivity 400 Amp rated 4 phase including neutral bus bar complete - 01 No.Incoming :-(b) MCCB4 -pole 160 Amp make-L & T,415 Volt,breaking capacity 36 KA,50 HZ with thermal magnetic release - 01 No.Outgoing :-(c)MCCB 4 - pole 125 Ampsbreaking capacity 25 KA, 50 HZ- 02 Nos. (d)MCCB 4 - pole 63 Ampsbreaking capacity 25 KA, 50 HZ- 01 No. 55 M&L for bus bar box of sheet metal 3 mm thick powder coated, having 4 Nos. aluminium bus bar of rating 200 Amp mounted on insulator including 01 No. of MCCB 4 pole 63 Amp 415 volts with thermal magnetic release as incomer, breaking capacity 25 KA inside the box and suitable fixing arrengement like flat iron clamp of size 25x3mm with hinged cover & locking arrangementincluding grouting of feeder piller box 60 cm above ground level by providing 90 cm long angle iron of size 40 X 40 X 6 mm welded on all the four corner embedded in PCC 1:2:4 using 20 mm graded stone aggregate complete duly painted with two coat of synthetic enameled paint over a coat of red oxide primer fixed in repair outdoor type duly fitted oncomplete all as directed by Engineer-in-charge. 56 Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable end termination heat shrink type joint complete with jointing material & accessories suitable for 3.5 core XLPEcable of size 16 sqmmto 35 sqmminsulated armoured aluminium cable complete all as specified and directed. 57 Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable end termination heat shrink type joint complete with jointing material & accessories suitable for 3.5 core XLPEcable of size 50 sqmmto 95 sqmminsulated armoured aluminium cable complete all as specified and directed. 58 Supplying ,laying, commissioning & testing 70 Sq.mm , 3.5 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking out old / unserveciable existing cablecomplete all as specified & directed.Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. 59 Supplying ,laying, commissioning & testing 50 Sqmm , 3.5 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including takingout old / unserveciable existing cablecomplete all as specified & directed.Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. 60 Supplying ,laying, commissioning & testing 35 Sqmm , 3.5 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking out old / unserveciable existing cable,complete all as specified & directed.Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. 61 Supplying ,laying, commissioning & testing 25 Sqmm , 3.5 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking out old / unserveciable existing cablecomplete all as specified & directed.Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. 62 Excavation in trenches, n. exc. 1.5 m wide and n. exc. 1.5 m in depth;for laying of cable, foundation, etc, or for shafts, wells, cesspits, manholes, etc. n. exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil,complete all as specified & directed. 63 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm,complete all as specified & directed. 64 Removing excavated material n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point,complete all as specified & directed. 65 M&L sand filling under floors or in foundations including watering and consolidation,complete all as specified & directed.Note :- Punned thickness shall be measured and paid. 66 Supplying & laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50mm (Note: cable cover shall be laid perpendicular to the axis of cable). 67 M&L for earthing complete with galvanised steel earth plate 600 x 600 x 6.3mm burried directly in ground (Earth pit not less than 2.25 m deep) with top edge of the plate not less than 1.5 m below ground level connected to GI strip of size 32 x 6 mm by means of nuts, bolts & washers,earth wire protected by GI pipe 50 mm dia ‘light grade’ ISI marked including charcoal dust, common salt, excavation & earth work, PCC Pit with 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate),40 mm thick precast RCC cover in 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handles 12 mm dia, PGI funnel & GI watering pipe ‘light grade’ ISI marked, 20 mm bore all as shown in Electrical plate No. 03 of MES Schedule Part-1 (2009) complete. 68 M&L GI pipes/tubes 80 mm bore,light gradeincluding necessary GI Fitting i.e. GI bends with socket ,reducer socket laid in trenches fixed on pole fixed on walls UG Road/floor for cable protection complete,complete all as specified & directed. . 69 M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25x4mm galvanised iron strip,complete all as specified & directed. 70 Chain Link FencingExcavation in post holes (or similar holes) in soft/ loose soil each n exc 0.5 Cum filling in and ramming earth or broken rubble mixed with earth around, complete all speecified and as directed. 71 PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in foudation for fencing post filling, and mass concrete, complete all as specified and directed. 72 Supply and Fixing Mild steel work Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed. 73 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire. 74 Supply chain link MS fencing galvanised mild steel wires 4mm diameter mesh size not less than 75mm x 75mm etc complete all as as specified and directed.
Contract Date: May 20, 2026 Contract Value : 5.24 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
21.
Tourism #11114098 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Cornices & Mouldings , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 150 Mm Strip Between Five Stone For Grassing.Strips To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.( Price Including Stone, Gardening Soil, Fertilizer And Grass Etc. ) , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Of Flashing Tape Along Wall And Tile Jointes ( Abutment Area ) Including Fixing Of Aluminium Strip Above Flash Including Sealing The Top Edge With Uv Resistant Sealant Etc Complete. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Extra For Plastering Done On Mouldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Mts. Lead. , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. A) Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. B) Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. C) Theming Work For Nandi Kalash In Frp As Per Tender Drawing , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Rough Dressing The Trenched Ground Including Breaking Clods. , Fine Dressing The Trenched Ground. , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Of Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevatia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Sebestena , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Foxtail Palms , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Callistemon (Bottlebrush Tree) , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Mimusops Elengi , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 60 To 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 40-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Pf=0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -5 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (A) 5 To 20 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying & Erecting Of Led 12W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A
Contract Date: Jul 02, 2026 Contract Value : 3.70 Crore
Government Departments No of Bidders 2
22.
Defence #11095458 AOC
Tender For Special Repair To Certain Technical Bldg At Af Stn Bkt; 1 Demolition of cement concrete of any description and in any position and complete removal of demolished material exc. 500 m but not exceeding 1.5km to outside Defence land complete all as specified and as directed. 2 M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in floor and finished rough to receive the floor tiles etc complete all as specified anddirected. 3 Dismantling floor, hearth or wall tiling including cement mortar bedding, terrazo dado from wall surface(but not backing), removing serviceable tiles to store and rubbish off the premises. Complete all as specied and directed. 4 M&L for Non - skid DigitalCeramicjoint lesscoloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and set in neat cement slurry and pointed with coloured/white cement to match the surface over and including15 mm thick screed bed in CM (1:4). Complete all as specied and directed.(Make-: Kajaria Tiles/HR Johnson/Somany) 5 M&L for glazed ceramic colouredDigital tiles in vertical surface300x600x7mm thick, set and jointed in neat cement slurry and pointed white or colored cement to match the surface over and including 10 mm thick CM (1:4) Complete all as specied and directed. (Make-: Kajaria Tiles/HR Johnson/Somany) 6 M&L for Vitrified digital double charge light coloured tiles 8-9 mm thick ( square or rectangular) polished, area of each tiles 600 mm X 600 mm as in floors etc.and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer with CM 1:4Complete all as specied and directed. (Make -Kajaria/ Somany/ HR Johnson) 7 Ditto all as per item No 06 above but on wall surfaces over and including 10mm thick rending in CM (1:4) complete all as specified and directed. 8 M&L for mirror rubbing & polishing of kota stone, where ever required to give glossy finish and half nose moulding (bull nosing) etc,complete all as specified and dirceted. 9 Demolition ofreinforced cement concrete of any description at groundfloor and complete removal of demolished material exc. 500 m and upto total distance of 1.5km to outside MoD Land complete all as specified anddirected. 10 Use and waste for formwork to sides and soffits of floor or room beams, beams haunchings, girders, bressummers, lintels, girders, bressummers, lintels, cantilevers, shelves includings supports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of concrete complete all as specied and directed. 11 M&L for Machine cut Cudappah stone slab size 25-30mm thick over cement screed base,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing Complete all as specied and directed. 12 M&L for Jet south black granite slab work 18 to 20mm thick (table rubbed and polished) in cooking platforms and jointing in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types over and including 15mm thick screed bed in CM (1:6)set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces and half nose moulding (bull nosing) etc, complete all as specified and directed. 13 M&L Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified directed. 14 Demolition of brick work built in cement mortar including all quoin, arches pillars but excluding ashlar facing dressed stone work and precast concrete article complete all specified anddirected. 15 M&L for Brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and as directed. 16 M&L for Brick work with subclass B bricks, old size bricks, straight or curved onplan exceeding 6 metre mean radius built in cement mortar (1:6)but except bricks Complete all as specied and directed. 17 M&L for Brick work with fly ash old size bricks, straight or curved to any radius in half brick thick walls, built in CM (1:4) complete all as specified and as directed. . 18 Taking down cement plaster on brick or concrete surfaces walls/chajja/roof,facia at any heigh including racking out joints hacking for key scrubbing down with water etc and M&L for rendering 15 mm thick in cement mortar (1:4) on fair face of brick work of walls mixed with water proofing compound (ISI Marked) @ 2% by weight of cement or as per manufacturers instructions finished even & smooth without using extra cement complete all as specified including mouldings chamfers splay srounded or coved angles. Beards grooves and rebate upto 10 cms in width or 15 cms in girth. Note: Supply only water proofing compound shall be measured and paid for seperately complete all as specified and directed. 19 M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistace as per IS 15489:2004. Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives @1.43 ltr/ 10 sqm over and including one coat of wall care putty 1 mm thick over priming coat of exterior primer applied @ 0.90 ltr/ 10 sqm over new/oldsurfaces complete all as specified and directed. Note: Putty,Primer and Emulsion to be carried out through air less spray machine complete all as specified and directed.(Mechanical Means) (Make:- Asian Paint Apex ultima/Berger weather coat long life 10/Nerolac Excel everlast 12) 20 M&L for complete removal of existing treatment on RCC/stone/concrete/brick walls including preparation of old surface by affixing wall care putty rubbing to smooth finishing and and applying two coat of 100% premium acrylic emulsion Comouflaging pattern having VOC less than 50gm/Ltr and UV resitance as per IS 15489-2004 alkali and fungal resistance, dirt resitance exterior paint of required shade (company depot tinted)with silicon additives @1.43 ltr/10 sqm over and including priming coat of exterior primer applied @09.ltr /10sqm over new prepare surface and height upto 9 meter complete all as specified and directed by and directed. Note : Primer and emulsion to be carried out through airless spray machine (Mechanical means)(Make Asian paint apex ultima/Berger weather coat long life 10/Nerolac excel everlast 12). 21 Supply only Integral water proofing compound complete all as specified and directed. 22 Taking down cement plaster on brick/stone walls/concrete in Roof/Chajja etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all specified and as directed. (Note :- Work will be carried out up to 3rd storey with necessary scaffolding). 23 M&L for rendering 15 mm thick on fair faces of brick or concrete surface walls, in cement mortar (1:6) rendering is to be finished even and smooth without using extra cement. 24 M&L for preparation of old distempered surfaces of wall by washing rubbing down and stopping of old distempered surface of wall including cornices etc and 1mm thick wall care putty as required for levelling and applying two coat of oil bound distemper (Oil emulsion any tint) on wall complete all as specified and directed.Note: Putty,Primer and Emulsion to be carried out through air less spray machine (Mechanical Means) (Make :- Asian Paint Tractor uno/Nerolac Beauty Acrylic/ Berger easy clean) 25 M&L for rendering 10 mm thick on fair faces of brick or concrete surfaceceilings, in cement mortar (1:3) finished even and smooth without using extra cement and applying two coat of white wash on new plastered surface of ceiling after preparation of surfaces complete all as specified and as directed. 26 M&L for preparation of old decorated surfaces by brooming down or steel wire brushing,scrappingdown smoke soot mould, moss and treading oil and greasy spots from plasterd or unplasterd surfaces of ceiling including cornices,pilasters etc and applying one coat of white wash complete all as specified and directed. 27 Taking down chowkats or frames areanot exceeding 1.50 Sqm(w/o taking off shutters from frames) and removing from site, including cutting holes for taking out existing hold fasts and making good in cement mortar (1:3) or PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate, complete all as specified and directed. (Note – The quoted rate shall be deemed toinclude for fixing of hold fast in the same opening irrespective of position of hold fasts and no separate item for making good of hold fasts shall be paid). 28 Taking down chowkats or frames area exceeding 1.50 Sqm andnot exceeding 4.00 Sqm (w/o taking off shutters from frames) and removing from site, including cutting holes for taking out existing hold fasts and making good in cement mortar (1:3) or PCC (1:2:4) type B0 ussing 12.5 mm graded stone aggregate, complete all as specified and as directed. (Note – The qouted rate shall be deemed toinclude for fixing of hold fast in the same opening irrespective of position of hold fasts and no separate item for making good of hold fasts shall be paid). 29 S&F factory made UPVC door frame white colour extrudedwith wall thickness of 2.3mm (+ -0.2mm). Corrner of door frame jointed with galvanised brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frame reinforcement by galvanised MS tube of size 19mm x19mm and 1mm (+- 0.10mm) wall thickness and 3 Nos stainless steel hines by the manufacture and as per directed.(Make :- Rajshree plastiwood/Kaka Industries/century plywood). 30 S&F factory made uPVC white colour casement (Openable) Door made of extruded profile with wall thickness of2.3 mm(+ 0.2 mm). Window profile with hollow section with mitlti chamber, frame (60 mm x 58 mm), sash (60 mm x 78 mm). T profile (onevertical length in between two shutters) (60 mm x 74 mm). Glazing bead (35 mm x 20 mm) will be mitered cutand fusion welded at all corners, including drilling of holes for fixinghardware and drainage of water etc. Making arrangement for fixing ofhardware. EPDM gasket 1.2 + 0.2 mm thick galvanized steel Frame (28 mm x 21.5 mm), sash (31 mm x 27 mm), T profile (27 mm x 17 mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners.(Hardware : casement doorhandle made of zinc alloyed (white powder coated), Corner striker, Secondary Strikers, Cylinder, Door transmission gear made of mild steel with multi point locking system with strikes 3D Hinges of zincalloyed (white powder coated) and 5 mm thick glazing with selected quality glass.}( Note : The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose).(Make :- Rajshree Plastiwood/Kaka Industries/century plywood). 31 S&F factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (112mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. locking arrengment as directed, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories area not exceeding 2.00 sqm each complete all as specified and directed. (Make:- Compreshive/Prominance/Fenesta. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.)(Make :- Rajshree Plastiwood/Kaka Industries/century plywood). 32 S&F factory made UPVC white colour fixed vent areaexceeding 1.00 sqmnot exc. 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass cmplete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose.) :-(Make :- Rajshree Plastiwood/Kaka Industries/century plywood) 33 S&F for sheet glass 5.50 mm thick, toughned glass, fixed in UPVC windiw including all fitting and fixturres complete all as specified and directed. Make:- Modigaend/ Saint Bobin/ Asahi India Glass. 34 S&F Factory made single extruded(Wood Polymer Composite) solid door/ window/ Ceosetory windows & otherFrames/ Chowkhat with double ribet of size 125mm x65 mmcomprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calciumcarbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity indexof 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threadedstar headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) &1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spreadof flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant with and encluding MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note:- For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(Make :- Rajshree Plastiwood/Kaka Industries/century plywood) 35 S&F factory madesingle extruded WPC (Wood Polymer Composite) solid decorative type 10mm deep CNCmoulding design with 0.12 micron laminated both sides shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame ofClass A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved designpasted with hot melt adhesive on both faces of shutter and fixing with and including stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and direction. (Make :- Rajshree Plastiwood/Kaka Industries/century plywood). 36 S&F Factory made single extruded WPC(Wood Polymer Composite) solid door/ window/ Ceosetory windows & otherFrames/ Chowkhat of size 45X70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calciumcarbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity indexof 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threadedstar headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) &1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spreadof flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with and including MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and direction. Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. (Make :- Rajshree Plastiwood/Kaka Industries/century plywood). 37 S&F factorymade single extruded WPC (Wood Polymer Composite) solid decorative type 10mm deep CnCmoulding design with 0.12 micron laminated both sides shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame ofClass A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved designpasted with hot melt adhesive on both faces of shutter and fixing with and including stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws. Complete all as specified and directed. (Make :- Rajshree Plastiwood/Kaka Industries/century plywood) 38 S&F for Aluminium anodised barrel tower bolts of extruded section 200mm long complete all as specifed and directed. 39 S&F 300 mm aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts complete all as specified and directed. 40 S&F Aluminium handles cast type anodised of 150mm complete all as spcecified and directed. 41 S&F butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed 100 mm long, type B-21 complete all as specified and directed. 42 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 43 S&F for mild steel framed work such as grills, gratings etc with ends of bars, M S pipe shouldered and or reiverted or forged into spikes, framed guard bars and similar work conferming to Fe- 290-0 Gde-E-165 complete all as specified and directed. 44 S & F for stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed withtinned tacks or galvanised wire staples complete all as specified and directed. 45 M&L for preparation of new or previously untreated steel surfaces of any description not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat ofzink chromeprimer including necessaryrubbing with sand paper or grinded byhand grinder to achieve smooth and even surface complete all as specified and directed. (Make :- Asian Apcolite Premium Gloss Enamel/Nerolac Synthetic High glass Enamel /Berger HI-Glass luxol ) 46 M&L for applying one coat of synthetic enamel paint to old painted steel surfaces of any description having width/girth exceeding 10 cmcomplete all as specifie including preparation and rubbing withsand paperto make surface even and smooth complete all as specified and as directed.(Make :- Asian Apcolite Premium Gloss Enamel/Nerolac Synthetic High glass Enamel /Berger HI-Glass luxol). 47 S&F in rplacement 20 mm nominal outer diaChlorinated Polyvinyl Chloride (CPVC) pipes SDR 11, having thermal stability for hot & cold water supply, including all Plain CPVC SDR 11 fittings & brass threaded fittings on walls/ceiling or laying in floors,including fixing the pipe with clamps. This includes jointing of pipes & fittings with one step CPVC solvent cement, complete all as specifed and directed. 48 S&F in replacement GI tubes medium grade galvanised, 20 mm bore, ISI marked with all fitting such as bends, tees,elbows, unions,short pieces, connectors, back nuts etc and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. 49 Dismantling water tanks and removing to store of water storage tanks (Cap. 500 ltr to 1000 ltr ) complete all as specified and directed. 50 Supply and fixingRotational moulded polyethylene water storage tanks of 500 litres capacity (white colour with threaded lid cover,minimum tripled layer , weight not less than 18 Kg), hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, highcomplete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete all as specifed and directed. 51 S&F in rotational moulded polyethylene water storage tanks of 1000 litres capacity (White colour with threaded lid cover, cylindrical vertical with closed topminimum tripled layer , weight not less than 33 Kg), white, hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, highcomplete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete all as specified and dircted. 52 S&F in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore pipe including making connections complete all as as specified and directed (Minimum weight 20mm-210 gms). (Make -: Prayag /JK Rubber Industries/Supreme Industries/ Prince/ JAL). 53 S&F in repair Gun metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, Bore dia of 20mm complete all as specified and as directed.(Make :- Zoloto/Leader/Bajaj) 54 M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in floor/ plinth protection laid in alternate bays finished even and smooth without using extra cement including joints filling by using mastic filling comprising one part of bitumen 85/25 mixed with three parts of coarse sand by weight complete all as specifed and directed. 55 S&F in repair PVC valveless,syphonic action type, flushing cistern, low level,white with inlet, ball valve, float and handle including brackets, PVC 32 mm L bend of capacity 10.0 litres and making good to dismantled/damaged floor/surfaces, fixing in repair, complete all as specified and as directed.(Make:- Jaquar/kohler/Grohe/ JAL). 56 S&F Vitreous china ware pedestal type water closet white, with P or S trap including self closing seat cover, closed pattern with flat bottom, 100 mm bore pipe & bedding in PCC (1:2:4) B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make:- Jaquar/kohler/Grohe) 57 S&F in repair CP Bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified complete all as specified and directed.(Make:- Jaquar/kohler/Grohe). 58 S&F in repair CP Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.(Make:- Jaquar/kohler/Grohe) 59 S&Fin repair angle valve with wall flange , cast copper alloy, chromium plated fancy type screwedfor 15 mm iron pipe, complete all as specified and directed. (Make:- Jaquar/kohler/Grohe) 60 S&F in repair PVC connection 15 mm x 450 mm including PTMT check nut at both ends screwed for iron pipe of 15 mm bore. complete all as specified and directed. 61 S&F in repairVitreous China, wash basin white, flat back , size 550mmx400 including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32 mm dia, waste coupling of waste couplingcomplete all as specified and as directed.(Make:- Jaquar/kohler/Grohe) 62 S&F in repairstainless steel Shop dish with PU foam complete all as specified and directed. (Make:- Cera/Prayag/Jaquar/kerovit) 63 S&F in repair for bevelled edge mirror of size (600mm x 450mm), selected quality glass approved size , mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with SS screws and cup washers complete all as specified and directed. 64 S&F in chromium plated brass Urinal auto closing type with built in control box & wall flange etc. complete all as specified and directed. (Make:- Cera/Prayag/Jaquar/kerovit ) 65 S&F in vitreous china half stall urinal with grating and union complete set with 40 mm dia GI light grade waste pipe including. brackets etc complete all as specified and directed. (Make:- Cera/Prayag/Jaquar/kerovit ) 66 S&F in urinal spreader chromium plated for fixing with 15 mm bore pipe etc. complete all as specified and directed.(Make:- Cera/Prayag/Jaquar/kerovit) 67 M&L for cutting chases, pinning in , making good to facings where required and pointing in cement mortar1:3 to ends or edges of landings,steps,cills,sunshades,shelves,lintels etc,and cutting chases for concealed water tubing or concealed conduit wiring,etc,and making good,cutting n.exc 10cm girth in brick walls complete all as specified and as directed. 68 Dismantling PVC/Cement/CI pipes 50 to 110 mm diaincluding allfittings like bend,branch pieces, connectors, heel rest bend etc and removing from site complete all as specifed and directed. 69 S&F in UPVC (SWR) type B pipes 110 mm bore single socketed, in any length with rubber ringjoints laid in trenches orin floors complete all as specified anddirected. 70 S&F UPVC (SWR) type B pipes 110 mm bore single socketed, in any length with rubber ringjoints fixedto walls including stack clamp of GI flat 50mm wide 5mm thick and 16mm dia fixed to wall with nail at spacing of 1m center to center ,complete all as specified and directed. 71 S&F in UPVC (SWR)type B pipes 75 mm bore single socketed in any length with rubber ringjoints, laid in trenches orin floors, complete all as specified and directed. 72 Supply and fixing, UPVC (SWR) , bends for75 mm bore , complete all as specified and as directed. 73 S&F in UPVC(SWR) , bendsfor110 mm borecomplete all as specified and directed . 74 S&F in repair UPVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. 75 M&L for high performance hybrid plyurea elastomeric waterproofing coating cold applied of spray/brush applied,samrtcare ulton liquid membrance at 1.5kg/sqm with an elongation of 600% and tensile strength of 12.6 N/sqmm as per ASTM D2370,crack bridging ability of 3.5mm as per ASTM C1305,shore a hardness of min 75 as per ASTM D2240.The system smartcare includes final base preparation as per site requirement,epoxy primer application and applying smart care Ultron or approved equivalent in two coats at a coverage of 1kg/sqm etc complete as per manufacturer specification including complete removal of old waterproofing system and repairing and cleaning the existing surface complete all as specified and directed.Make :- Asian Paints/ STP/ Berger/ Sika/ Pidilite. 76 M&L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope commplete all as specified and directed. 77 M&L for cement concrete (1:2:4) type B1 using 20mm graded stone aggreate as in benching , haunching kerb etc rounded or chamfered on edges including necessary formwork complete all as specified and directed 78 M&L for PCC (1:4:8) type D-2 using 40 mm graded aggregate as in sub base of 100 mm thickness complete all as specifed and directed. 79 M&L for precast factory made Chequered tiles of size 300mm x 300mm glazed topmade in whitecement and pigment base of thickness not less than 19mm in differentcolourand pattern(compressive strength not less than 250 kg/sqcm) set and jointed in neat cement slurry cover and including 20mm thick screed bed in CM (1:4)complete all as specifed and directed. 80 M&L for plain cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregatein lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and as in benchingand similar work including necessary form work complete all as specifed and directed. 81 S&F Anodised aluminium powder coated snap grid frame workexposed suspended system grid size 595mm X 595 mm comprising of GI powder coated main T -3600/crossT-600/size 25X35X0.7mm, wall angle 25X0.7mm & soffit cleat 37X25X1.80mm thick including dismantling of wll and ceiling boards of any thickness with cover fillets complete all as specifed and directed. (Make -: Everest / Armstrong/Techno Ceiling Product) 82 S&F hanger of4mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40mm x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed (Make -: Everest) 83 S&F Non asbestos fibre cement building boards 4 mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specifed and directed.(Make -: Everest / Armstrong/Techno Ceiling Product) 84 Taking down copper/aluminium point wiring for (light, fan, socket or power) complete including unserviceable fittings such as switches, ceiling rose, holders, sockets,light fittingsetc. and making good the disturbed surfaces on wall/floor etc complete all as specified and directed.Note- (i) Dismantled serviceable light fitting shoud be kept in safe custodyfor reuse.(ii) Refixing of serviceable fitting shall be paid seperately under relevant items- 85 Refixing of serviceable light fittings upto 22 watt obtained form item No 84 above including connecting up with 3 core flexible cable copper conductor of suitable size from ceiling rose complete all as specified and directed. 86 Taking down fans/meter/Geyser/Exhaust fan from existing position and removing the same and depositedto MES store and will installed after completion of work. complete all as specified and directed. 87 Taking down old and unserviceable sub main wiring any size/type /core incl earth wire complete with batten conduit etc complete all as specifed and directed. 88 Taking down old and unsv sheet metal enclousure ,switch fuse unit,distribution board any type/way/capacity including fuses mcbs ,insulator rccbs etc copmlete after removing all connectionand making good the disturbed surface complete all as specifed and directed. 89 Refixing of serviceable MCBs 5-32 Amp rating 240 Volt 10 KA including connection and commissioning including providing lugs and thimbles complete all as specifed and directed. 90 M & L for point wiring with two single core PVC insulated & PVC unsheathed FRLS-H multistranded copper conductor cable of size 1.5 sqmm 1100 volt gradein non metallic rigid PVC concelled conduit medium grade 25 mm dia with all accessories mounting all the surface of wall/ceiling/roof/etc with suitable size of module metal flush boxes and including modular front coverplate & back plate for mounting modular type switches /socket/fan/ regulator etcincluding provision of one single corePVC insulated and unsheathed multi stranded copper cable of size 1.5 sqmm 1100 volt grade as earth continuty conductor connected to common earth dollyswitch board complete for following-Make of Cable- Plaza/Finolex/Havells/Polycab. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex.One light/fan point controlled by one switch SP 5 Amps ,240 V 91 One 3 pin 5 amps switch socket outlet point on independent board complete all as specifed and directed. 92 Ditto all as per item No 90 above but for One 3 pin 5 amps socket point on same board complete all as specifed and directed. 93 Ditto all as per the item No 90 herein before but with 2.5 sqmm conductor for5 pin 15 Amps switch socket outlet. complete all as specifed and directed. 94 S&F switch modular type 1 module single pole, one way 5 Amps complete all as specifed and directed.Make - Goldmedal/cabtree(havells)/ABB 95 S&F switch modular type 1 module single pole, one way 15 Amps. Complete all as specifed and directed.Make - Goldmedal/cabtree(havells)/ABB 96 S&Fsocket outlet 2 in 1, 5 pin, 15Amps modular type 2 module complete all as specifed and directed.Make - Goldmedal/cabtree(havells)/ABB 97 S&F socket outlet 5Amps modular type 2 module complete all as specifed and directed.Make - Goldmedal/cabtree(havells)/ABB. 98 M&L ceiling rose,PVC/polycarbonate, isolated body complete all as specifed and directed. 99 S&F Submain wiring with two single core PVCinsulated FRLS multistrand copper conductor cable of size 10Sq mmdrawn into and including non metallic heavy duty rigid concealedPVCcondute not less than 25mm size ISI marked ivory colour (Pressfit or similar brand ) with allfittings / accessories and 10Sq mm FRLS multistrand copper conductorcable as continuous earth wire complete. Not:- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesis deemed to be included in the quoted unit rate for this items.)Make- Polycab/Havells/RR kables/plaza. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex 100 S&F Submain wiring with two single core PVCinsulated FRLS-H multistrand copper conductor cable of size 04 Sq mmdrawn into and including non metallic medium duty rigid concealedPVCcondute not less than 25mm size ISI markedwith allfittings / accessories and 04 Sq mm FRLS-H multistrand copper conductorcable as continuous earth wire complete. Make- Polycab/Havells/RR kables/plaza (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesis deemed to be included in the quoted unit rate for this items.)Make- Polycab/Havells/RR kables/plaza. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex 101 S&Fsheet metal enclosure double door (MCCB DB) three phase and neutral with 200 Amps rated bus bar VTPN,4 way vertical type, with provision of MCCB incommer, AC, 415 Voltcomplete all as specified & directed.Make :- Havells / Legrand /Seimens/L&T / C&S. 102 S&F Sheet metal enclosure 12 way double door distribution board when MCB to be used SPN 240 volt sheet complete all as specified and directed.Make :- Havells / Legrand /SeimensL&T/ C&S. 103 S&F MCCB 4 pole 100 / 125 Amp 415 volts 50 HZ25 KA breakingcapacity complete all as directed.Make :- Havells / Legrand /Seimens L&T/ C&S. 104 S&FMCB SPN 40 to 63 Amps 240 volt,50 hz,10 KA breaking capacity :C curved type complete all as specified and directed. Make :- Havells / Legrand /Seimens L&T/ C&S. 105 S&F MCBsingle pole, 6 to 32Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.Make :- Havells / Legrand /SeimensL&T/ C&S. 106 S&F socket outlet 5 pin 20 amp modular type 2 module with suitable size of module metal flux boxes and including modular front cover plate and back plate for mounting modular type switch & socket with one single poleone module MCB of 20 amp including electrical connection all as specified and directed.Make-Havells/ABB/Goldmedal L&T/ C&S. 107 S&F in LED light fittings 1x18/20 watt ,220 volt AC decorative box type with driver holder including 18 watt LED tube light connecting up with 3 core flexible cable copper conductor of suitable size from ceiling rose complete all as specified and directed .Make - Phillips/Havells/Bajaj L&T. 108 S&Fin square recessed / surface/suspendedmounting LED ceiling light with extruded aluminium housing and milky diffuser of 36 W 2X 2panel complete with LED driver 240 V ,50 Hz,3600 lumen 6500 k complete all as specified & approved by EIC Make - Phillips/Havells/Bajaj/ L&T. 109 S&F in LED security light 60 watt complete with security light bracket (complete with two set of clamp ,nut and bolt) made out of 40 mm medium grade GI pipebend to shape and with fixing arrangements duly welded (length of pipe should not be less than 1.2 mtrs) and making conection with using 1.5 sqmm PVC insulated multistranded copper conductor two single core cable complete all as specified and directed.Make - Phillips/Havells/Bajaj/ L&T. 110 Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the type and sizes50 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.Make : Plaza/ Finolex / Polycab /RR cable/ Havells 111 Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed. 112 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soilcomplete all as specified and directed. 113 Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. 114 M&L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed. (Note:- Punned thickness only shall be measured & Paid). 115 M&L for precast cable cover class LV type 1 flat size 250mm x 150mm x 40mm, laidflat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specifed and directed. 116 M&L for Horizontal boring in soft/loose soil/under roads of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables complete all as specified and directed by Engr-in-Charge. Note : GI pipe shall be measured and paid separately under relevent items given here-in-after. 117 M&L for 80mm dia steel tubing, galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified and directed.Make -Jindal/Tata/Finolex /Prakash Surya. 118 S&F exhaust fan made of sturdy engineering plastic complete with louvers shutter volt 230 V 50 Hz RPM 1200 copper winding of sweep 250 mm. complete all as directed and specified and directed.Make:- Havells/Philips/crompton/Bajaj/ L&T. 119 Supply installation and testing of wall mountedAir circulator 400 mm sweep with high speed and aerodynamically designed Acrylonitrile Butadienealuminium blades / body, jerk free and smooth oscillation and inbuilt regulator system chord complete all as specified and directed. Make:- Havells/Philips/crompton/Bajaj/L&T. 120 M&L forflame proof pointwiringwith two single core FRLS-H PVC insulated& PVC unsheathed multi stranded copper conductor cable of size 1.5Sqmm1100 voltsgradein and includingstove enamelled steel conduit of size20 to 25 mmwith all accessories and one single core PVC insulated & PVC sheathed multistranded FRLS-H copper cable of size 1.5 Sqmm 1100 Voltsgradeas earthcontinuityconductorconnectedto commonearth dolly, switch board complete incuding cutting chesses on wall/ floour/ ceiling etc. & making good the disturbed surface with 1:4 cement morter all as specified for one light / fan point controlled by one 5 Amps flameproofswitch one way complete all as specifed and directed. 121 Supply and fixing LED Light Fitting 2x20 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &III B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable with suitable sizecomplete all as specified and directed. Make:- Philips/ Bajaj/ Crompton/ Bajaj/ L&T. 122 S&F flame proof metallic body exhaust fan single phase 230 Volt 50 Hz 300 mm 1440 RPM with louvers and shutter including civil work i.e making of holes and complete with all fixing accessories all as specified and directed by E-in-Charge . Make :- Shyam / Bajaj/ Crompton/ Bajaj/ L&T. 123 M&L for switch flame proof rotory type with termination box in LM 6, 16 A,single phase 250 volts,complete all as specified and directed.Make- Legrand/ Scimens/Havells/ L&T/ C&S.
Contract Date: Jan 21, 2026 Contract Value : 27.99 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 9
Uttar Pradesh View Result →
23.
Tourism #11085444 Technical Bid
Tender For Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer. , Supplying And Filling Moorum In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry In Cement Mortar 1:3 (1Cement : 3 Coarse Sand) With Bricks Of Class Designation 75 Kg /Cm2. B. Upto Floor V Level. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs, Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of Sail, Tata, Vizag Made Only (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. Minimum Grade Of Steel - Fe 500 , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4B Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint.In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Providing & Fixing In Position Galvalume/Zincalume Flashings, Cappings, Ridges, Gutters Upto 600Mm/610Mm Girth And Min 3.00M In Length (Cold Rolled Steel 550 Mpa Yeild Stress Astm A 446 Grade E) With Hot-Dip Metallic Coating Of Aluminium-Zinc Alloy(Az 150 Galvalume) (150 Gms/Sqm Total Of Both Sides With Al-Zn Composition= 55% & 43.5% Resp. & 1.5% Si Conforming To Astm 792/ As 1397) 0.45 Mm Base Metal Thickness And 0.50Mm Total Coated Thickness, Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respects With Az 150 Gsm Smp Color Coated (20Mic Exterior Coat Of Silicon Modified Polyester Paint System Over 5 Mic Primer And 5 Mic Polyester Back Coat Over 5 Mic Primer) Incl. Fixing To Purlins With No 12X14X55Mm Mechanically Galvanised Hex Head Self Drilling Screws Of The Best Quality As Per As-3566 Class 3-4 Approved, Which Should Be Compatible To Be Used With Sheets. With Integral Washers And Epdm Seals Etc. Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. Plain Grill , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excludingfixingaccessoriessuchasnuts,Bolts, Fasteners Etc.). , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. Light Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Jet Black With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. ( Price Range 2000 To 2100 Rs Per Sq Mtr.) , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. ( Price Range 1550 To 1600 Rs Per Sq Mtr.) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm .80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Fixing 18Mm Thick Polished Black Granite Machine Cut For Kitchen Platforms, Counters, Window Sills, Door Frame, Urinal Partitions , Fascia And Similar Locations Of Required Size Of Approved Shade, Colour And Texture Laid Over 20Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing,Moulding And Polishing To Edge To Give High Gloss Finish, Etc. Complete At All Levels.( Price Range Rs.1500 To Rs.1700 Per. Sq.M ) , Providing 25Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 60 Cm L X45 Cm H X 15 Cm T , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand). 20 Mm Thick. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 (1 Cement: 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , 12 Mm Thick Cement Plaster 1:4 (1 Cement:4 Fine Sand) , 6Mm Thick Cement Plaster To Ceiling With 1:3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer , Extra For Plastering Done On Moldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws , Plugs And Priming Coat On Unexposed Surfaces Etc. 50X12Mm Size. , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 300X 16 X 5 Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Provided And Fixing 150 Mm Chromium Plated Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutters Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete. 200 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Window With 3 Tracks And 2 Shutters Sliding Window With Tobular Frame Ployster Powder If Thicness 75-80 Microns With Approved Standard Accessaries Such As Ball Beaing Rollers, Concealed Lock, 6Mm Thick Plain Clear Glass With Epdm Beading Etc. , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete. 10 Mm Dia , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete.12 Mm Dia , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead Extra For Dismantling Trusses, Rafters, Purlins Etc. Of Steel Work, For Every Additional Span Of One Meter Or Part Thereof Beyond 10 Mts. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Doors, Windows And Clearestory Windows (Steel Or Wood) Shutters Including Chowkhats Architrave Holdfast Etc. Complete And Staking Within 50 Mt. Lead. Of Area 3 Sq.M. And Below , Dismantling Wood Work Of Area Below 40 Sq.Cm. Wrought Framed And Fixed In Frames, Other Frames And Trusses Including Stacking Of Material Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Nandi In Frp As Per Tender Drawing , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Laying 300X350X160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete) , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Or Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Saraca Ashoka , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Nyctanthes , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Filliciam Decipiens , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Dichotoma , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Millingtonia Hortensis , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Jacaranda Mimosifolia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neolamarckia Cadamba , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevetia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Alba , Supplying & Planting Shrubs, Creepers, Ground Covers, As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. , Providing And Fixing White Vitreous China Type Water Closet Squatting Pan (European Type W.C. Pan) With Dual Flushing (Citren Nelson/ Similar)With Stop Cock Wall Flanges Flush Pipe Or Elbow And Vacuum Breaker Coupling Etc. Including Cutting Making Good The Walls And Floors Where Required. (Excluding Handicap Toilets) , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430 X 260 X 350 Mm And 340 X 430 X 265 Mm Sizes Respectively With Pvc Automatic Flushing Cistern With Fittings, R.S. Or C.I. Brackets, Standard Size Galvanized Steel Flush Pipe And Spreaders With Brass Unions & G.I. Clamps Complete, Including Painting Of Cistern And Fittings, Cutting And Making Good The Walls And Floors Where Required. (A)One Urinal Basin With 5 Liters P .V .C. Automatic Flushing Cistern. , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Including Cutting And Making Good The Walls Where Required. Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws. Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Wall Mixer With 3 In 1 System With 115Mm Long Bend Pipe For Connection To Over Head Shower Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing C.P. Brass Towel Rail Complete With C.P. Brass Brackets Fixed To Wooden Cleats With C. P. Brass Screws. 750X20 , Providing & Fixing Soap Dish Chromium Plated With Brackets Fixed To Wooden Cleats With Cp Brass Screw , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed .110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed. 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating.110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door :110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door :110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door 110Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door . 75Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Providing And Fixing R.P.V.C. Vent Cowl: 75Mm , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Cm2 In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar. , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:.B) 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 32Mm Outer Dia. , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 15Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 40 Mm Nominal Bore . , Providing And Fixing Non-Return Valve Of Approved Quality :40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality .25 Mm Nominal Bore , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 25 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 32 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 40 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 50 Mm , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701;1996. 1000 Lit. Capacity , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70B50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Wall Mounted Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length Complete. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (B) 10 To 40 A , Supply, Installation, Testing And Commissioning Of 3 Kva 1 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. (E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Square / Circular Max. 20 W Pendent Light With Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd10%, P.F. 0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Suspended Accessories Complete. , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii))
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
24.
Public Administrative Department #11036124 AOC
Tender For Construction Of Three Class (Ground And First Floor) School Building.; 1 Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS 20B and Sand, silt or other loose soil, wet sand, silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and completed, cleaning and levelling the site etc., complete Narrow Foundations - First Depth Upto 2.00M 2 Narrow Foundations - Second Depth - 2.00M - 3.00M 3 Open Earth Work Excavation 4 Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 5 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 6 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plinth Beam 7 Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 8 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13cm dia spaced at not more than 75cm centre to centre etc. complete complying with the standard specificaiton. - For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. 9 Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officersUpto Basement 10 Ground Floor 11 First Floor 12 Second Floor 13 Supply and fabrication of steel required for all RCC items of works involved in the schedule, cost of steel at site fabrication, labour charges for cleaning the rods straightening, cutting, bending, tying grills, including overlapping to the required length whenever necessary and placing the reinforcement in position as as per design given and specified in the drawings, including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc complete as per standard specification 14 Supplying and filling the basement with Carted Good Earth 5Km away from the site and filling in layers of not more than 15cmthick well rammed watered and compacted - etc., complete complying with standard specification. 15 Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9X43/8X 23/4 standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost) - Upto Basement 16 Ground Floor 17 First Floor 18 Second Floor 19 Brick Partition walls in CM 1:3 (one cement & three Crushed Stone Sand (M- Sand)) using IIclass ground moulded bricks of size 9X43/8X23/4 using hoop iron reinforcement 2 Nos of 6mm dia M.S.rod at every three alternate layers and the cost shall inclusive of iron reinforcement, Brick work etc, complete as per standard specification - Ground Floor 20 First Floor 21 Second Floor 22 Manufacturing supplying and fixing ofMILD STEEL Window made out of 40 x 40 x 6 mm M.S angle for outer frame, 35 X 35 X 5mm M.S.Angle for outer frame of shutter. The entire shutter area shall be covered with CRC sheets (18 G) with 5Nos of stiffners using M.S.Flats of size 25 X 6mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash butt welding or any other suitable method. Provision towards 3Nos, of Hinges incase of single shutters / 6Nos of Hinges incase ofDouble shutters of 125 X 31 X 1.25mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop 1No. The frame shall be provided with 6Nos,of Hold fast of 200mm length using 50 X 6mm M.S.Flat. The entire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemendal officers. 23 Manufacturing supplying and fixing ofMILD STEEL DOOR made out of 50 x 50 x 6 mm M.S angle for outer frame,35 X 35 X 5mm M.S.Angle for outer frame of shutter. The entire shutter area shall be covered with CRC sheets (18 G) with 5Nos of stiffners using M.S.Flats of size 25 X 6mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash butt welding or any other suitable method. Provision towards 3Nos, of Hinges incase of single shutters / 6Nos,of Hinges incase ofDouble shutters of 125 X 31 X 1.25mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop 1No. The frame shall be provided with 6Nos,of Hold fast of 200mm length using 50 X 6mm M.S.Flat. The entire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemental officers. 24 Special ceiling plastering in all floors and finishing the exposed surface of RCC items of work such as slab, beam, sunshade, facia, canopy slab, staircase waist slab, landing slab etc., with cement mortar 1:3 (One cement and three plastering sand (P- Sand)) 10mm thick including hacking the surfaces and providing cement mortar nosing, beading for sunshade, staircase, step, landing slab etc., including neat finishing and curing etc., complete complying with standard specification and as directed by the departmental officers. 25 Plastering with cement mortar 1:5 (One cement and five plastering sand (P- Sand)) 12mm thick in all floors including cost and conveyance of all materials to site etc,complete as per standard specifications 26 Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being 32:12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete as per standard specification. 27 Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three plastering sand (P- Sand)) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 28 Plain Cement Concrete 1:8:16 (one cement eight Commercial Sand (M- Sand) and sixteen coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying water carrying with all leads of good water compacting and labour charges and all incidential charges such as water providing etc., complete as per standard specification 29 Paving the floor with kota stone slab of size 600 x 600 of 18 / 20mm (un-polished) in all floors laid in of cement mortor 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. 30 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 31 Painting two coats of newly plastered wall surface with ready mixed exterior emulsion paint of first quality and of approved colour over a priming coat including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required etc., complete complying with standard specification. 32 Painting the new iron work with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat and including cost of painting materials, brushes, putty, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer. 33 Paving the Platforms with one side Pre- Polished Cuddapah Slabs of required size 40mm thick in all floors over a base layer of cement mortar 1:3 (one cement and three Plastering sand (P- Sand)) 20mm thick laid in-situ and pointed with same coloured cement etc, complete as per standard specification. 34 Providing & fixing PVC RAIN WATER DOWNFALL PIPE of 110mm dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of U clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] 35 Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). SD 23 36 Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. SD 38 37 Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour. SD 54 38 Supply and fixing of single box type 436 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting SD 87 39 Supplying and fixing of 1200mm ( 48 ) sweep AC ceiling fan complete with regulator with 1M down rod including S & F of fan clamp with side plates and cross arm SD 107 40 Earthing as per P.W.D. standard with an earth electrode of 2Mtr. Class B GI pipe of dia not less than 32mm complete with necessary masonry work.SD 234 41 Supply and fixing of 3 phase 4 wire 4 way ICDB of 32 A per way with 100 A TPN MC switch with suitable trunking box Ms cable entry boxes and internal connection on suitable angle iron frame work with earth connectionSD. 175 42 Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40 A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCBs should be with the ISI mark (lik standard make) SD. 179 43 Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of 1.5m SD.75 44 Supply and run of 4 X 6 sq.mm (84/0.3) 7/20sqmm PVC unshealed copper cable in suitable PVC rigid pipe concealed on wall and ceiling withcontinuos earth wire connection of 14 SWG TCwire with painting of suitable colour SD 68 45 Wiring with 2 x 4sqmm (56 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for15A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC power plug point.SD 40 46 Supply and fixing of TNEB Board suitable for 3 Phases 63A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2 x 1 1/2 x 1/4 rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 63A fuse units(500V) 1 No. Neutral link, copper earth flat of size 1 x 1/4 with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete.SD 131 47 Plain Cement Concrete 1:1.5:3 (one cement, one and half Crushed Stone Sand (M- Sand) and three coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges etc., complete as per standard specification 48 Providing and laying, spreading and compacting graded stone aggregate to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH Rev V specifications. 49 Supplying and laying Rubberised interlocking Paver blockM40 grade Providing and laying of83mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, Stone Dust cushion 150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
Contract Date: Sep 19, 2024 Contract Value : 93.68 Lakh
Local Bodies No of Bidders 2
25.
Agriculture #10988522 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In, All Kinds Of Soil , Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.M20 Grade Nominal Mix / Design Mix , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Columns, Pillars, Posts And Struts Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786)Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Brick Work With Clay Flyash F.P.S. Brick (Is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And Two Corners Are Free , Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , P & F 1St Qualityheavy Duty Vitrified Polished Digital Tiles On Floor, Skirting And Steps Etc.In Different Sizes (Thickness Minimum 10Mm) With Water Absortion Less Than Or Equal 0.08% And Conforming To Is 15622 Of Approved Make In All Colour And Shade, Laid With 20 Mm Thick Cm 1: 4 Including Grounting The Joints With White Cement And Matching Pigment Etc Complete.Size 600Mm X 600Mm , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Extra For Using Size Above 200X300mm In Glazed Tiles And For Using 400Mm X 400Mm Mat Finished Tiles In Place Of 300Mm X 300Mm Size. Wall Tiles , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Chargeprofile C : , Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). , Providing And Fixing M.S. Sheet 1Mm Thick Single Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge , (A) Window Openable. , (B) Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dark Shade Using Ordinary Cement. , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :12Mm Thick . , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 20Mm Thick . , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Fixed Portion Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Is : 6315 Marked, For Doors Including Cost Of Cutting Floors As Required, Embedding In Floors And Cover Plates With Brass Pivot And Single Piece M.S. With Stainless Steel Cover Plate , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge.(Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.)With Float Glass Panes Of 5.0 Mm Thickness ( Weight Not Less Than 13.50 Kg/Sqm) , Providing And Fixing Expanded Grill Made Of Aluminum As Per Design And Drawing Having Members Section Of Size 7.5Mm X 6.0Mm And Opening Of Size 102Mm X 99Mm To Aluminum Window/Vent With Required Screws, Y And H Aluminium Sec (As Per Drawing) At The Ends And Middle Joints Respectively Complete In All Respect As Per Direction Of Engineer In Charge.Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , Providing And Fixing Curtain Rods Of 1.25 Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs, Etc., Wherever Necessary Complete: 20 Mm , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. , Carriage Of Earth Incloding Loading ,Unloading Without Stacking With Lea Of 5Km , Making Grooves As Per Design In Plaster 10Mm To 20Mm Wide. , Extra For Plastering Done On Moulding Cornices Or Architraves Including Neat Finish To Line And Level: In Two Coats , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated ‘J Or ‘L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified.5.0Mm Thick (Wt. 8.4 Kg./Mtr. Sq.) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Crazy Marble Stone Flooring 20Mm Thick Marble Stone With Black Or Of Specified Colour Topping Including Filling The Gaps With Cement Marble Chips Mix In Proportion Of 4 : 7 (4Cement : 7 White Black Or White Or Black Marble Chips) Size From 1Mm To 4Mm By Volume And Under Layer Of 25Mm Thick Cement Concrete [1:2:4, Graded Stone Aggregate 12.5Mm Nominal Size] Rubbing And Polishing And Cement Slurry Etc. Complete : In Ordinary Cement. , Extra In Marble/Other Flooring Work For Upto 50 Mm Wide Strip Of Green/White/ Jaisalmer Stone In Flooring Work As Per Direction Of Engineer In Charge , Providing & Fixing Precast Cement Concrete Coping 1 : 2 : 4 Mix 50Mm Thick Complete As Per Specification : , Renewing Glass Panes,With Putty And Nails Wherever Necessary Float Glass Panes Of Thickness 5 Mm , Filling Of Sunk Portion Of Roof With Earthen Pots Of Required Height Including Filling Voids With 1:3:6 Light Concrete, Using Brick Bats Complete Levelling And Dressing The Surface By 50Mm Thick Cement Concrete 1:2:4 As Per Specification. , Supply And Fixing In Cement Mortar Welded Hand Railing Made Out Of Ms Round Or Square Bars, Flats Etc. For Staircase Or Verandah As Per Design Complete In All Respect (Wooden Or Pvc Hand Railing To Be Paid Extra) With Priming Coat Of Red Oxide. , Extra For Providing D Type Pipe Head As Top Of Hand Railing , Providing And Fixing Almirah Lock (50 To 70 Mm Size )Of Approved Make Without Pair Of Handles For Door With Necessary Screws Etc Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Grade 304 , Lettering With Black Japan Paint Of Approved Brand And Manufacture. , Construction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layers With Tractor Mount Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Smooth Wheel Roller To Achieve The Desired Density, Complete As Per Morth Specification Clause 401..For Grading Iii Material , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 5.00Km As Per Morth Specification Clause 305.3 , Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mixer (Pug Mill), Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers In Sub-Base/Base Course On A Well Prepared Sub-Base And Compacting With Smooth Wheel Roller Of 80 To 100Kn Weight To Achieve The Desired Density Including Lighting, Barricading And Maintenance Of Diversion, Etc As Per Tables 400-12 & 400-13 And Morth Specification Clause 406.By Mechanical Means With All Lead , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 80 Mm As Per Drawings And As Per Is 15658:2006.And All Materials Shall Conform To Morth Specification Clause 602.With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blockscategory B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Dia. Nominal Bore. , Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 200Mm Dia. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. 200Mm Normianl Bore , Supply Of Erw M.S. Black Casing Pipe Isi Marked Is:4270/ 1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 200Mm Normianl Bore , Development Of Tube Well As Per Is Specification Using Suitable Compressor To Give Sand Free Water For Required Yield Of The Gravel Packed Tube Well. , S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size:200Mm Dia. , S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete :Solid Pvc (Is 2548 Marked) Grade-I Black For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend And Superior Internal Fittings As Per Is : 7231 . , P & F Flush Pipe Of Approved Make With Complete Fittings For High Level Flushing Cistern: Pvc Exposed (Heavy) 32Mm. , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : , Size 580 Mm X 450 Mm , Size 630 Mm X 500 Mm Dia For Counter Top , P & F Bevelled Edge Mirror/Mirror With Teak Wood Lipping Around Of Special Glass Of Approved Make As Per Direction Of Engineer-In-Charge Complete With 6Mm Thick Commercial Ply Base Fixed To Wooden Screws & Washers. Size 600 X 450Mm X 4 Mm Thick , P & F Towel Rail Or Ring Of Approved Quality/Make: , C.P. Brass Towel Rail Elbow Type With Concealed Screws Size 450Mm (Heavy Duty). , P & F Grating Of Approved Quality/Make: , Stainless Steel Sheet Size 125Mm Dia. , P & F Liquid Soap Container With Brackets Complete Of Approved Make: , P & F Jet Spray For Water Closet With C.P. Copper Tube Flange Of Approved Make. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Making Connection Of G.I. Distribution Branch With G.I. Main Including All Fitting. , Upto 25Mm Dia , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: , C.P. Brass Bib Cock,15Mm Nominal Bore. , C.P. Brass Bib Cock Long Body, 15Mm Nominal Bore Weight Not Less Than 690 Gm , P & F Ball Cock (Is :1703 Mark) With Rod & P.V.C. Ball Complete : Brass Wt. Not Less Than 300 Gm,15Mm. , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make : Pvc Pipe With C.P. Brass Nuts Upto Length 450Mm. , P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make : , Gun-Metal 15Mm Nominal Bore. , Gun-Metal 25Mm Nominal Bore. , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 1000 Litres Capacity , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia , P & F S.W. Master Trap (Inter-Cepting) A Grade (I.S.: 651 Marked) Of Approved Quality/Make 150Mm Dia , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: 110Mm Dia , Coupler (Socket) , Plain Tee , Bend 45 , Vent Cowel , Pipe Clip , Multi Floor Trap , Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade cement concrete Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead. Depth Up To 0.5 M , Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick cement concrete 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr. -Do- Size 600 X 450Mm Depth Upto 0.5 M Cement Cover With Frame. , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Construction Of Recharge Shaft In Filter Pit Including Earth Work Excavation , Lifting Excavted Earth With All Lift And 50 M Lead And Centering & Shuttering Evenever Required.Diameter 900 Mm , Supply & Fixing Pre-Cast Reinforced Cement Concrete Rinngs At The Mouth Of Recharge Shaft Of M20 Mix With 40 Mm Thicknessdiameter 900 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In All Kinds Of Soil , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :20Mm Thick . , Finishing With Neat Cement (Punning). , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix. , Add Extra For Providing Richer Mixes Respectively At All Floor Levels, Providing M-25 Grade Concrete By Using Min 410 Kg Of Cement Per Cum Instead Of M-20 Grade Design Mix. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting (Height Upto 10 M) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , Inside Size 600X450mm Upto Depth Of 0.5M & 38Kg Ci Cover With Frame , 250Mm Dia Internal. , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii(4 Kg. /Cm.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant, 160Mm Dia. , 250Mm Dia S.W. Pipe. , P & F 60 Cm. Wide M.S. Ladder In Open Well Made Of Flat Iron 32X5mm And 10Mm Dia Bars @ 200Mm C/C With Angle Iron Hold Fasts At Suitable Interval Complete As Per Drawing. , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Nominal Bore , P & F G.I. Pipes (Internal Work) With G.I. Fittings (Is:1239-1992 Mark) & M.S. Clamps Including Cutting And Making Good The Walls And Floors : Exposed On Wall, 15 Mm Dia Nominal Bore. B - Class. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. , Size 9 To 12 Mm , Size 3 To 5 Mm , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of Twin Control Light Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 2 Nos Hot Dipped Galvanized M.S Modular Box Of 1.2 Mm Thick With Earth Terminal,2 Nos10 A Two Way Modular Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector ,Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr..) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , On Board , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , S&F Following Sizes (Dia.) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Mm , 32 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 2X 1.5 Sq.Mm , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , 4 X 10.0 Sq.Mm , 4 X 16.0 Sq.Mm , Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Providing & Fixing Of Wiring Accessories Oem Fabricated Following Size Gi Box Of 1.2 Mm Thick With Earthing Terminal And Adjustable Floating Clamp In Recess/ Surface Suitable For Modular Accessories As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1/2 Module , Providing & Fixing Of Following Size Mounting Grid Plates With Cover Plates Made From Fire Retardent Uv Established High Performance Engineering Plastic Suitable For All Universal Metal Boxes For Front Installation & Removal Direct Fit Type Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1-2 Module , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Single Pole Mcb (With B/C Curve Tripping Characteristics) , 6 A To 32 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box , 6 Way , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For Mcb / Rccb And Sp / Tp Mcb As Outgoing ,Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door (For Double Door Db Only ) Complete With Insulated 100 A Rating Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Double Door Ik-09 & Ip-43 With Metal End Box , 6 Way(8+18) , Providing & Fixing Of 240/415 V Isolator Isi Marked Is:13947-Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Four Pole Isolator , 80 A/ 100 A Rating , Triple Pole Isolator , 63A Rating , Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Amp. 2 Module Motor Starter With On / Off Push Button , Blanking Plate , Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 5 Step Fan Regulator 2 Module 360 Dgree Rotating , Providing & Fixing Of Modular Type Switch/ Bell Push Duly Isi Marked (Is :3854) With Cm/L No. Printed And Made Out Of Unbreakable And Fire Retardant Vergin Uv Stabilized Polycarbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating ,Minimum Width Of Switch Toggle( Push Part ) Should Not Less Then 20Mm, Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 10 A Bell Push , Providing & Fixing Of Ding Dong/Musical Chime Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply Installation Testing and Commissioning of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Improvement =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , 3 Pole Mccb With Thermal Magnetic Release , Up To 100 annual periodical maintenance , 25 Ka, Adjustable O/L & Adjustable S/C Setting, , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 35.0 Sq. Mm , 3.5 Core , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Supplying And Making End Termination With Heavy Aluminium Lugs ( Pin / Ring Type ) Confirming To Is 8309 -1993 & Is 8337-1976 Duly Crimped With Crimping Tool, Pvc Tape Etc Of Following Size.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 35.0 Sq.Mm , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 50 Mm , Labour Charges For Excavating Trenches Of Required Width For Pipes Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr.: , All Kind Of Soils , Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor ,Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 300 Mm Sweep , P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Reqd. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Up To 380 Mm Size , Providing & Fixing Of Energy Efficient Direct Fit (Retrofit) Polycarbonate/ Glass Housing Smd Mid Power Led Tube Rod (With Integral Driver & Alumn. Heat Sink ), On Existing Fixture. System Lumen Efficacy ≥ 100 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv ,Thd 20% ,P.F.≥0.95,Cri 80 , Life Time Of Minimum 35000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80)Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200Mm , Min. Lumens Output 2000 Lm Led Tube Rod With Polycarbonate Housing , Providing & Fixing Of Ip20, 2X2 Led Surface/ Recessed Mounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/External Surge Protection Bis Certified Isolated Driver Having Efficiency 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 10 % , P.F.≥0.95,Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Moutning , Minimum Lumen Output 3600 Lm , Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Mounting (With Extruded Alumn. Housing ) , Minimum Lumen Output 1300 Lm , Minimum Lumen Output 1950 Lm , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached. , 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Led Street Light Fixture With Minimum Lumen Output 12500 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 32 Mm Dia. , Supply Installation Testing and Commissioning of Mnre Approved & Confirming To Is:12933 P-1,2,3 & 5 Flat Plate Collector Type Solar Hot Water System Having Collector With Zincalum Sheet Outer Body , Glass - Line / Titanium Enamel Coated Inner Tank With Metal Rust Proof Puf Insulated Body Including Electrical Back Up, Thermostat, Powder Coated / Hot Dipped Galvanized Ms Stand For Collector & Tank Etc. As Required. Of Following Capacity Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 250 Litre/ Day , Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 4 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1.5 Tr Iseer Not Less Then 3.8 , Supply Installation Testing and Commissioning of Monoblock Motor Pump Set Isi Marked (Is:9079-2002) With Tefc Motor, Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011. With Stainless Steel Impellor, Stainless Steel Shaft, Mechanical Seal, Single/Three Phase ( 240 - 440 V ) Permanent Split Capacitor Type (Psc), Fitted With Thermal Overload Protection, Including Cost Of Hardware Etc On Existing Platform Complete. Pump Shall Have Following Hp Rating, Phase, Head, Minimum Discharge Respectively Complete In All Respect. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 2.0 Hp, 3-Ø, (6-27)Mtr, (425-100) Lpm , Supply Installation Testing and Commissioning of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , For Single Phase Submersible / Monoblock Pump , 2.0 Hp To 3.0 Hp (Dol Starter)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
26.
Power #10907633 AOC
Construction Of New Test Lab Building At 33/11 Kv Sub Centre, Fatehabad And Other Related Civil Works. - Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(DSR 2.8) All kinds of soil. (DSR 2.8.1) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR )(DSR 2.25) 5 Excavating, supplying, stacking and filling of local earth (excluding royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. NSI Based on(DSR 2.25(a)) 6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26) All kinds of soil (DSR 2.26.1) 7 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (DSR 2.28) All kinds of soil (DSR 2.28.1) 8 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. (DSR 2.3) All kinds of soil (DSR 2.30.1) 9 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.31) 10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2) 11 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.3) 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) 13 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.2.2) 14 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3) 15 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) 16 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) (DSR ) (DSR 4.10) 17 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. (DSR )(DSR 4.12) 18 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) 19 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (DSR 5.2) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2) 20 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.3) 21 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) 22 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4) 23 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5) 24 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) 25 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7) 26 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15) 27 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1) 28 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19) 29 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.12) 30 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.13) 31 Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR )(DSR 5.15) 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)/ (DSR 5.22A.6) 33 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) 34 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) 35 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) 36 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) 37 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (DSR 6.13) Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) 38 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab upto 0.50 sqm (DSR 8.2.1.1) 39 (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2) 40 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2) 41 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. (DSR )(DSR 8.4) 42 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR )(DSR 8.5) 43 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. (DSR )(DSR 8.6) 44 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : (DSR 8.14) Red sand stone - exposed face fine dressed with rough backing. 8.14.1 30 mm thick (DSR 8.14.1.5) 45 Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : (DSR 8.28) Decorative veneer facings of approved manufacture (DSR 8.28.1) 46 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 18 mm thick (DSR 8.30.1) 47 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 25 mm thick (DSR 8.30.2) 48 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 8.31) 49 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (DSR 9.1) Sal wood (DSR 9.1.2) 50 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 35 mm thick shutters (DSR 9.5.1.1) 51 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 30 mm thick shutters (DSR 9.5.1.2) 52 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (DSR 9.7) Second class teak wood (DSR 9.7.1) 53 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 35 mm thick (DSR 9.9.1.1) 54 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 30 mm thick (DSR 9.9.1.2) 55 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR 9.11) 5.0 mm thick(weight not less than 12.50 kg per sqm) instead of 4 mm thick(weight not less than 10 kg per sqm). (DSR 9.11.1) 56 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR )(DSR 9.12) 57 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR )(DSR 9.14) 58 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Panelled or panelled & glazed shutters : 9.16.1 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.1.2) 59 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Glazed shutters : 9.16.2 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.2.2) 60 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 12 mm thick (DSR 9.17.1) 61 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 18 mm thick (DSR 9.17.2) 62 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) 63 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x12 mm (DSR 9.40.2.1) 64 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 25 mm dia (heavy type) (DSR 9.47.2) 65 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to steel windows by welding (DSR 9.48.1) 66 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 125x65x2.12 mm (DSR 9.57.1) 67 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2) 68 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 75x47x1.70 mm (DSR 9.57.3) 69 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2) 70 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 200x10 mm (DSR 9.63.2) 71 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 150x10 mm (DSR 9.63.3) 72 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1) 73 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 100 mm (DSR 9.66.2) 74 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 75 mm (DSR 9.66.3) 75 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.1) 76 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.15.2) 77 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16) Electric resistance or induction butt welded tubes (DSR 10.16.3) 78 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. (DSR )(DSR 10.17) 79 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR )(DSR 10.18) 80 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2) 81 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR )(DSR 10.28) 82 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) 83 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1) 84 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR )(DSR 11.2) 85 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1) 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) 87 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR )(DSR 11.27) 88 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR )(DSR 11.37) 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41) Size of Tile 600x600 mm (DSR 11.41.2) 90 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (DSR 11.48) Size of Tile 600x600 mm (DSR 11.48.2) 91 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR 12.41) 110 mm diameter (DSR 12.41.2) 92 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 75 mm (DSR 12.42.1.1) 93 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 110 mm (DSR 12.42.1.2) 94 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (DSR 11.56) Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent (DSR 11.56.1) 95 Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). (DSR 12.64) 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. (DSR 12.64.1) 96 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1) 97 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:6 (1 cement: 6 coarse sand) (DSR 13.4.2) 98 15 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:4 (1 cement: 4 coarse sand) (DSR 13.5.1) 99 15 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:6 (1 cement: 6 coarse sand) (DSR 13.5.2) 100 12 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2) 101 6 mm cement plaster of mix : (DSR 13.16) 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) 102 Neat cement punning. (DSR )(DSR 13.18) 103 Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. (DSR ) (DSR 13.20) 104 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR )(DSR 13.21) 105 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (DSR 13.41) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre (DSR 13.41.1) 106 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) 107 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR )(DSR 13.80) 108 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour(DSR 13.81) Old work (one or more coats) (DSR 13.81.1) 109 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR )(DSR 13.88) 110 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR )(DSR 13.91) 111 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) 112 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (DSR 13.111.1) 113 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (One or more coat applied @ 0.90 ltr/10 sqm). (DSR 13.111.2) 114 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) 115 Renewal of old putty of glass panes (length) (DSR )(DSR 14.9) 116 Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR )(DSR 14.79) 117 Providing & fixing White vitreous china water closet squatting pan (Indian type) along withS or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2) 118 DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (DSR )(DSR 14.82) 119 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (DSR 15.2) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (DSR 15.2.2) 120 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR )(DSR 15.3) 121 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7) In cement mortar (DSR 15.7.4) 122 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): (DSR 15.8) From brick work in cement mortar (DSR 15.8.3) 123 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area 3 sq. metres and below (DSR 15.12.1) 124 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.19) 125 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : (DSR )(DSR 15.24) 126 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) G.S. Sheet (DSR 15.28.1) 127 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (DSR )(DSR 15.52) 128 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR )(DSR 15.56) 129 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. (DSR )(DSR 15.58) 130 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR )(DSR 15.60) 131 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. (DSR )(DSR 16.42) 132 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. (DSR )(DSR 16.44) 133 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR )(DSR 16.53) 134 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR )(DSR 16.68) 135 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR 16.7) Made of G.I. wire of dia 4 mm (DSR 16.70.1) 136 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR )(DSR 16.75) 137 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. (DSR )(DSR 16.76) 138 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) 139 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1) 140 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) 141 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) 142 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR )(DSR 17.7A) 143 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2) 144 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1) 145 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR )(DSR 17.31) 146 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms (DSR 17.69.1) 147 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2) 148 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3) 149 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 20 mm nominal bore (DSR 18.15.2) 150 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 20 mm nominal bore (DSR 18.16.2) 151 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 25 mm nominal bore (DSR 18.17.1) 152 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore (DSR 18.17.1A) 153 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 32 mm nominal bore. (DSR 18.17.2) 154 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 20 mm nominal bore (DSR 18.21.1.2) 155 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 20 mm nominal bore (DSR 18.21.2.2) 156 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR )(DSR 18.48) 157 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR )(DSR 18.65) 158 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : (DSR 19.5) 100 mm diameter (DSR 19.5.1) 159 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.1.1) 160 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2) 161 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.1.3) 162 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.2.1) 163 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2) 164 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3) 165 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR 21.3.1) 166 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 21.3.2) 167 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (DSR 21.3.3) 168 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With stainless steel cover plate minimum 1.25 mm thickness (DSR 21.4.1) 169 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With brass cover plate minimum 1.25 mm thickness (DSR 21.4.2) 170 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). (DSR )(DSR 21.5) 171 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. (DSR )(DSR 21.6) 172 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (DSR )(DSR 21.18) 173 Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq mm frls pvc insulated copper conductor single core cable in surface /recessed medium class pvc conduit , with modular switch ,modular plate, suitable GI box and earething the pint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR E&M 1.10)Group A (DSR E&M 1.10.1) 174 Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulatted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) 175 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x2.5sq. Mm + 1x2.5 sq. mm eartrh wire (DSR E&M 1.14.2) 176 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x4sq. Mm + 1x4 sq. mm eartrh wire (DSR E&M 1.14.3) 177 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 1.21) 25mm (DSR E&M 1.21.2) 178 Supplying and fixing 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on Surface/recess,complete with tinned copper bus bar, heutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator) (DSR E&M 2022 2.3.1) 179 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) 180 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR E&M 2022 2.12.2) 181 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 2022 5.2) 182 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (DSR E&M 2022 19.1) 183 Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 ) 184 Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (CSI No. 5.20) 185 Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.18) 186 Brick work in Super structure with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.19) 187 S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (CSI No. 9.22) 188 Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia 189 Supply and fixing of power plug with 15A/250 voltflushtype switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mmsize with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 2018 PWD 1139 190 Supply and fixing ofLED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. 2018 PWD 1413(A)CAT AA 191 S/F of LED Bulb 9Watt bajaj or equivalent make as approved sample and make as per direction of Engineer in charge (NSI) 192 S/F of 07 Watt LED bulb Syska or other equivalent make including cost of labour, T&P etc required for proper completion of the work (NSI) 193 Providing and lowering of 32 mm dia. uPVC column pipe Finolex/Ashirwad or equivalent make with column coupling socket etc. including cutting the pipe of required length, proper jointing the same including cost of all materials, labour, T&P etc required for proper completion of work.(NSI) 194 Supply and fixing support clamps for 32mm dia column pipes made out of MS flats, pairs of bolt-nuts etc complete with all material, labour, T&P. (CSI No. 19.24 e) 195 Supply & installation of electrical control panel of L&T / Havells or equivalent make for 1.5/2.00 pump set single phase submersible pump / pumpset containing contractor relay condenser. (CSI No. 19.31b) 196 Supply & Installation of 2.00 HP outlet 40mm dia. or more, Head 89/45, Discharge 2000/6000 LPH submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (CSI No. 19.32c) 197 Supply and fixing of 2.5 mm2 for pump above 1 HP and up to 3 HP submersible cable Havels or equivalent make, for submersible pump complete in all respect. (CSI No. 19.33b) 198 Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (CSI No. 19.34) 199 Mild Steel or Iron work in heavy sizes such as trusses built up gates, door frames, record, racks roof work gates etc. wrought to required form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost when steel is to be provided by the department. (CSI No. 9.02) 200 Supply and fixing CP Nahani Trap India make of heavy approved quality complete with CI grating, including supply of all materials,labour and T&P etc. required for proper completion of the work. (CSI No. 27.21b) as above but for 100 mm.PVC trap. 201 Providing and fixing CI GRATING 100 mm dia including all materials, labour cartage T&P etc.required for proper completion of the work. (CSI No. 27.25) 202 Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI) 203 Providing and fixing 12 mm thick Industrial tiles size 300 x 300 mm or more of Kajaria or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete (NSI) 204 Water proofing treatment over Roof, wall, Chajjas, Balcony etc. with Engineer Plus 7 layer waterproofing system at leakage, seepage area consisting of Surface preparation roughening of surface, opening of cracks in V groove in size of 5 mm to 10 mm width, Back filling of cracks with SBR Latex, 2 layer Spraying Mixture of Aquasil-99 and Aquaprime-99 (Take 20 liter clean water+ 1 liter Engineer Plus Aquasil-99 + 2 liter. Engineer Plus Aquaprime-99 in proportion 20:1:2 This solution should not sprayed over more than 40 sqm area, 3rd Laying 90GSM fiber glass mesh with proper overlap, 4th coat of brushable mortar prepared with Engineer Plus Aquaprime-99, water & cement (Aquaprime -99 @ 0.45 kg per sqm, water @0.45 kg per sqm & cement @0.68 kg per sqm.) in the proportion of 1:1:1.5 by weight, After 4th coat allow the coating to air cure for minimum four hours, after 4 hours interval apply, 2 coat of Flexicoat-99 mixed with Water (Flexicoat-99 @0.33 kg/sqm, water @0.66 Kg per Sqm) in the proportion of 1:2 by weight in 4 hours interval. After 6th coat allow the coating to air cure for minimum 4 hours. After 4 hours interval apply, 7th coat of Engineer Plus smartcoat-99 (Smartcoat-99 @ 0.45 Ltr/sqm & water @ 1.35Ltr/sqm in the proportion of 1:3). The surface will dry within 2 hours and surface would be fully water proof and usable after a period of 24 hours and the final appearance of the coating will be gray/milky white. The rates are included the cost of all chemicals, labours, and Required T&P for Proper completion of Work.
Contract Date: Apr 29, 2026 Contract Value : 36.93 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
27.
Tourism #10881944 Technical Bid
Tender for Furniture Supplying Of Bed Headboard Paneling Made In 19Mm Marine Plywood With 0.1Mm Laminate Finish From Outside And In Middle Bed Headboard With Foam 32D And Fabric As Chosen For The Back Restoration Size: 14Ft X 4Ft , Supplying Of Designer Molding Above The Bed Headboard With Wooden Patti 2 X 1 With Designer Patti With Deco Paint Finish. Size: 14Ft X 1Ft With Concealed Coved Light On The Headboard . , Supplying Of Double Bed Made In 19Mm Marine Gurgen Plywood With 0.1Mm Laminate Finish Brand Greenply Century Or Equilant Brand. Size: 78 X 72 X 16 , Supplying Of Bed Side Table Made In 19Mm Marine Gurgen Plywood With 0.1Mm Laminate Finish Brand Greenply Century Or Equilant Brand. Size: 18 X 16 X 24 , Supplying Of Non Woven Wallpaper Above The Bed Headboard Including Installation Charges. Size: 11Ft X 4Ft , Supplying Of Dressing Unit Made In 19Mm Marine Gurgen Plywood With 0.1Mm Laminate Finish Brand Greenply Century Or Equilant Brand With 4Mm Mirror Company Saint Gobin With Appropriate Handles And Fixtures. Size: 36 X 90 X 26 , Supplying Of Dressing Unit Stool Made In Sal Wood Frame With High Density Foam And Fabric As Per The Chosen. Size: 20 X 24 X 18 , Supplying Of Wardrobe Made In 19Mm Marine Gurgen Plywood With 0.1Mm Fabric Colour Laminate Finish Brand Greenply Century Or Equilant Brand With Appropriate Handles And Fixtures With Inside 2 Drawers And Shefls With Access Rod For Hanging Cloths Wardobe Size: 4.6Ft X 7Ft X 24 , Supplying Of Luggage Rack Made In 19Mm Marine Gurgen Plywood With Teakwood Frame Size 2 X 1.5 With 18Mm Stone Marble Finish With Edged Polished On Top. Size: 3.10Ft X 2Ft X 22 , Supplying Of Tv Unit Made In 19Mm Marine Gurgen Plywood With 0.1Mm Glossy Colour Laminate Finish Brand Greenply Century Or Equilant Brand With Appropriate Handles And Fixtures With Inside 2 Drawers. Size: 6.7Ft X 2Ft X 24 , Supplying Of Working Desk Made In 19Mm Marine Gurgen Plywood With 0.1Mm Glossy Colour Laminate Finish Brand Greenply Century Or Equilant Brand With Appropriate Handles And Fixtures With Inside 2 Drawers. Size: 3Ft X 2Ft X 24 , Supplying Of Working Desk Chair Made In Teakwood Frame With High Density Foam And Fabric As Per Chosen With Melamine Polish. , Supplying Of Curtain Pelmet Made In 16Mm Marine Plywood With Laminate Finish With Double Curtain Tracks. Size: 11.4Ft X 2Ft , Curtain Fabric Main (80% Blackout With 100% Polyster Material Easy To Maintain Wash) Brand - Ddecor Size: 11.4Ft X 8.5Ft , Curtain Fabric Sheer (100% Polyster 54 Width Light Weight Easy To Maintain Wash) Brand - Ddecor Size: 11.4Ft X 8.5Ft , Curtain Installation And Stitching Charges For Window Size: 11.4Ft X 8.5Ft , False Ceiling Made In Gyproc Borad With Required Metal Support / Chanel Patti / Rafter Patti / L Patti (Isi Marked ) Etc. All The Materials Used For The Above Item Shall Confirm To The Latest Relevant Is Standards. Size: Size: 22.5Ft X 11.6Ft Including Cutiing Charges For Light Fixtures And Ac Drains , Supplyng Of Sofa Arm Chair Made In Sal Wood Frame With High Density Foam And Fabric Suede Type 400Gsm Fabric As Per The Selection. Size: 30 X 18 X 20 , Supplying Of Center Table Made In Teakwood Frame With Melamine Polish With Top 12Mm Clear Glass. Size: 3Ft X 2Ft , Bathroom Fixtures Providing & Installtion Of Sanitory Ware - Counter Top Basin Brand - Hindware/ Kohler/ Cera / Parryware / Jaguar Or Equilant Other Brand With Bottle Trap 300Mm And Polished Chrome. Model No. K-7314In-Cp , Sanitory Counter - Carcass- Made Of 50Mmx 50Mm Gi Tube Coverd With Marine Plywood / Acrylic Limaniate / Top Made Of Indian Stone - Granite / Jaislermer/ Makrana Etc Edges Witll Diamond Polished With Blunt Edge Profile / Led Lighting / Dustbin & Tissue Throw Cut Provisioned , Western Styled Toilet Seat - Make Of Cera/ Hindware/ Jaguar Etc , With Health Faucet, Tab, Tissue Holder / Storage Tank Etc With Installation , False Ceiling - Made Of Grid Pattern Pvc Multiwall Celing , Supplying Of Toilet Door Made In Teakwood Frame With 20Mm Blockboard With Laminate Finish With Appropriate Hanges And Handles- With 304 Ss Accessories - Auto Door Closer , Mirror -6Mm Clear Mirror Float Glass All Edge Polished Height - 3.5 Ft , Width As Per Requirement - Irrespetive Of Small Or Big Sizes Pof Area Mounted On 16Mm Thick Marine Plywood , Exhuast For Urinal Area And Basin Area 4 Dia Pvc Pipe Ducting / Inline Fan Etc , Supplying Of Square Shower Head With Shower Arm In Polished Chrome - Model No. K226451n-Cp - Brand - Kohler , Supplyin Of Square Hand Shower Without Hose In Polished Chrome - Model No. K970091n-Cp , Supplying Of Bath Spouts With Diverter In Polished Chrome - Model No. K-2351In-Cp , Supplying Of Shower Enclosure With Toughned Glass And Hanges And Fittings With Rubber - Model No. K-704699In-Shp (Id2p-S In) Upto 3000 Mm Running Length , Supplying Of Angle Valve And Polished Chrome - Model No. K-23515In-4-Cp , Supplying Of 2 Way Bib Tap In Polished Chrome - Model No. K-20075In-4-Cp , Supplying Of Click Drain Big Cap In Polished Chrome - Model No. K-7120In-Cp , Supplying Of Towel Shelf In Polished Chrome - Model No. K-25066In-Cp , Supplying Of Square Tissue Holder With Cover In Polished Chrome - Model No. K-25071In-Cp , Supplying Of Towel Ring In Polished Chrome - Model No. K-5631In-Cp , Supplying Of Tissue Holder In Polished Chrome - Model No. K-5632In-Cp , Supplying Of Soap Dish In Polished Chrome -Model No. K-5634In-Cp , Supplying Of Tumbler Holder In Polished Chrome - Model No. K-5637In-Cp , Supplying Of 6L Step Can In Stainless Still Dustbin _ Model No. K-17531T-St , Bath Of Bath Grip In Polished Chrome - Model No. K-10701D-Cp , Supplying Of Outdoor Furniture Chairs Made In Aluminum 18 Gauge Pipe With Plastic Cane With High Density Foam Using Outdoor Sunbrella Fabric All Weather Proof As Per The Design Selected. Size: 30 X 20 X 18 , Supplying Of Outdoor Furniture Center Table Made In Aluminum 18 Gauge Pipe With Plastic Cane As Per The Design Selected. Size: 3Ft X 2Ft , False Ceiling Made In Pvc Sheet For Outdoor Use Using Gyproc Borad With Required Metal Support / Chanel Patti / Rafter Patti / L Patti (Isi Marked ) Etc. All The Materials Used For The Above Item Shall Confirm To The Latest Relevant Is Standards Including Cutiing Charges For Light Fixtures And Ac Drains , Designing Of Floor Plan For The Layout Purpose Including 3D And 2D With Floor Plans False Ceiling, Tiling, Furniture, Plumbing And Electrical Designing. , Designing Of 3D With Colours Scheme And Cordination With Execution Planning And Statistics Including Space Management And Consulting Charges , Electrical Items 25Mm Condut Pipe - Brand Sudhakar , 25 Mm Junction Box - Brand Sudhakar , 25 Mm Bend - Brand Sudhakar , Insulation Tape - Sudhakar , 1 Module Plate Metal Box - Brand Legrand Lyncus , 2 Module Plate Metal Box - Brand Legrand Lyncus , 3 Module Plate Metal - Brand Legrand Lyncus , 4 Module Plate Metal Box - Brand Legrand Lyncus , 6 Module Plate Metal Box - Brand Legrand Lyncus , 8 Module Plate Metal Box - Brand Legrand Lyncus , 1 Sqmm Wire - Brand Polycab , 1.5 Sqmm Wire - Brand Polycab , 2.5 Sqmm Wire - Brand Polycab , 4 Sqmm Wire - Brand Polycab , Cat 6 Cable - Brand D Link , 1 Module Plate - Brand Legrand Lyncus , 2 Module Plate - Brand Legrand Lyncus , 3 Module Plate - Brand Legrand Lyncus , 4 Module Plate - Brand Legrand Lyncus , 6 Module Plate - Brand Legrand Lyncus , 8 Module Plate - Brand Legrand Lyncus , 5 Amps Switch - Brand Legrand Lyncus , 5 Amps Sockets - Brand Legrand Lyncus , 15 Amps Switch - Brand Legrand Lyncus , 15 Amps Socket - Brand Legrand Lyncus , Telephone Socket - Brand Legrand Lyncus , Outside Room - Bell Push Switch - Brand Legrand Lyncus , Room - Regulator - Brand Legrand Lyncus , Room - Main Switch Key Tag - Brand Legrand Lyncus , Room - Fan 48 Inches - Orient,Havells, Crompton , Balcony - Fan 24 Inches - Orient,Havells, Crompton , Bathroom - Celing Exhaust - Brand Orient,Havells, Crompton , Bathroom - Geyser 5L - Brand Crompton, Recoilt , Room - 12 Watt Cob - Brand Panasonic, Wipro, Philips , Bathroom And Wardrobe - 7 Watt Cob - Brand Panasonic, Wipro, Philips , Room - Strip Light 24O Led , Balcony - 12 Watt Cylinder , Room - 3 Module Laser , Balcony - Bollard , Room - Hanging Light , Bathroom And Dressing - Picture Light , Bed Side - Wall Lamp , Corridor - Surface Panel - Brand Panasonic, Wipro, Philips , Wardrobe - Cabinet Light - Brand Wipro, Ledure , Wardrobe - Wardrobe Sensor- Brand Sensonova , Bathroom - Bathroom Sensor - Brand Sensonova , Room - Bell , Room - Foot Lamp (Indoor) , Balcony - Foot Lamp (Outdoor) , Electrical - Wiring And Cabling, Switches And Sockets Installation, Lighting Fixtures And Rectification, Concealed Work Conduit Laying ,Final Inspection , Room - Tv (43 Inches) , Room - Fridge , Room - Kettle , Bathroom - Hair Driyer , Bathroom - Hanging Telephone , Room - Telephone , Room -Digital Locker , Door - Door Lock Rfid - Brand Yale, One Touch, Goderej , Corridor - 25 Mm Conduit (1.2 Mm ) 3 Mtr - Brand Sudhakar , Corridor - 1 Sqmm Multistand - Brand Polycab , Corridor - Surface Panel 15 Watt - Brand Panasonic, Wipro, Philips , Corridor - 4 Module Plate - Brand Legrand , Corridor - 6 Amps Switch - Brand Legrand , Corridor - 4 Module Metal Box - Brand Legrand , Labour Charges For Electrical Work , 25 Mm Conduit (1.2 Mm ) 3 Mtr- Brand - Sudhakar- For Corridor , 25 Mm Band - Brand - Sudhakar , 25 Mm J Box - Brand - Sudhakar , 2.5Sq Mm Wire - Brand - Polycab , 1 Sqmm Multistand - Brand Polycab For Corridor , Surface Panel 15 Watt - Brand Panasonic, Wipro, Philips , Mcb Box - Brand Legrand , Mcb 32 annual periodical maintenance 3 Pole - Brand Legrand , Mcb 16/32 - Brand Legrand , 4 Module Plate - Brand Legrand , 6 Amps Switch - Brand Legrand , 4 Module Metal Box , Erting , Civil Works Breaking Of Toilet Wall And Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block - D3,D8,D7,D5,D6,D1,D4 , Breaking Of Waterproofing In Sunken Area For Provision Of Plumbing Pipes, Shifting The Debris, And Disposing Off The Same Including Cost Of Transportation, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing Crystaline Waterproofing For Toilet Sunk And Wall Upto 1Mtr Height, Including Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Filling Sunken Slab With Hard Laterite Or Rubble Stone Upto 200Mm Ht, With 1:3 Cement Mortar Mixed With Waterproofing Compound, Including Material And Labour Complete. Block D2,D8,D7,D5,D6,D1,D4 , Providing And Applying Smooth Waterproof Cement Plaster 18Mm Thich In Cement Mortar (1:3) To Reinforced Cement Concrete And Masonary Surfaces Mixed With Waterproofing Compound, Including Smooth Patra Finish, With Material And Labour And Material Complete. Block D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing Single Coat Plaster For Toilet Walls Upto 12Mm Thick In (1:4) Cement Mortar, Including Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing In Position Readymade Tiles Of Nitco,Somany, Kajaria Make Of Approved Colour And Sizein Dado/Wall As Per Design, Including Cutting To Proper Size, Fixing To Level In Cement Paste, Filling The Joints With Matching Colour, With Material And Labour Complete (Basic Rate = Rs 800/Sq.Mtr) Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D3,D8,D7,D5,D6,D1,D4 , Providing And Fixing Granite Counter For Wash Basin In Toilet, Including Full Moulding For Edges, With Material And Labour Complete.(Basic Granite Rate = Rs. 200/Sq.Ft) Block D2,D3,D7,D5,D6,D1,D4 , Breaking Of Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Skirting Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Balcony Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Balcony Skirting Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D2,D3,D8,D7,D5,D6,D1,D4 , Breaking Of Balcony Coping Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Block D8,D7,D5,D6 , Providing And Laying In Position Readymade Floor Tile For Flooring Of (Size 2*2/4*2)Size Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Skirting Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D32,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Balcony Flooring Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Skirting Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D2,D3,D8,D7,D5,D6,D1,D4 , Providing And Laying In Position Readymade Floor Tile For Balcony Coping Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. Block D8,D7,D5,D6 , Breaking Of Concrete Sopo In Balcony, Shifting The Debris And Disposing Off The Same Including Transportation Construction Block D2,D3,D1,D4 , Breaking Of Old Damaged Plaster From Internal Ceiling And Wall. Block D3,D8,D7,D6,D1,D4 , Providing And Fixing Single Coat Plaster For Ceiling And Walls Upto 12Mm Thickness, In (1:4) Cement Mortar, Including Material And Labour Complete. Block D8,D7,D6,D1,D4 , Breaking Of Passage Floor Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete. Tile From Pardi Top,Wall Tile In Staircase, Staircase Step, Ground Floor Passage Floor,External Steps,Duct And Store Room Floor,External Step For Block 1 & 4 , Breaking Of Passage Floor Skirting Tile And Shifting The Debris, And Disposing Off The Same Including Transportation Cost, With Material And Labour Complete.Ground Floor Passage Flooring, Duct And Store, Staircase Skirting , Providing And Laying In Position Readymade Floor Tile For Flooring Of (Size 2*2/4*2)Size Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. First Floor Passage Flooring, Tile From Pardi Top, Ground Floor Passage Floor, Duct And Store Room Floor , Providing And Laying In Position Readymade Floor Tile For Skirting Of Nitco, Somany, Kajaria, Make Of Approved Colour And Size In Flooring As Directed To Proper Levels And Lines Including Setting In Cement Mortar(1:3) 25Mm Thick And Joined With Cement Slurry, Including Filling The Joint With Matching Colour Grout. With Material And Labour Complete. (Basic Rate = Rs. 800/Sq.Mtr. First Floor Passage Flooring, Ground Floor Passage Flooring, Duct And Store, Staircase Skirting , Providing And Laying In Position Jet Black Granite In, Steps Tread As Directed To Proper Levels And Lines Including Setting In Cement Mortar (1:3) 25Mm Thk And Joined With Cement Slurry, With Material And Labour Complete. Staircase Step, External Step , Painting Work Application Of 1 Coat Damp Proof Primer And 2 Coat Apex Ultima Paint For Ceiling And Walls, Including Cost Of Scaffolding, With Material And Labour Complete. , Application Of 2 Coat Cement Based Putty, 1 Coat Internal Primer And 2 Coat Premium Emulssion Paint For Ceiling And Walls, Including Material Nad Labour Complete. Room No. D5,D6,D7,D8,D1,D4,D2,D3 , Application Of 1 Coat Primer And 2 Coat Ace Emulsion For Ceiling And Walls Of Staircase And Passage, Including Material And Labour Complete. , Application Of Oil Paint For Railing And Grill, Including Material And Labour Complete. , Plumbing Work Providing And Fixing Upvc Pipes For External Work Confirming To (Astral Flow Guard/Supreme ) Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fitting S Including Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Cheses And Testing 11/2 Pipe Ing Upvc Pipes For External Work Confirming (Astral Flow Guard/Supreme ) Having Thermal Stability For Cold Water Supply Including All Upuc Plain Elbow Tee And Fitting S Including Jointing Of Pipes And Fittings With One Step Upvc Solvent Cement And The Cost And Testing 11/2 Pipe , Providing And Fixing Upvc Pipes For External Work Confirming To (Astral Flow Guard/Supreme ) Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fitting S Including Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Cheses And Testing 11/2 Pipe Ing Upvc Pipes For External Work Confirming (Astral Flow Guard/Supreme ) Having Thermal Stability For Cold Water Supply Including All Upuc Plain Elbow Tee And Fitting S Including Jointing Of Pipes And Fittings With One Step Upvc Solvent Cement And The Cost And Testing 2 Pipe , Providing And Fixing S.W.R Soil And Waste Pipes. Isi Marking/ Rubber Ring Joints All Special Such As Bends,Tee, Reducers Etc.4 Pipe , Providing And Fixing S.W.R Soil And Waste Pipes. Isi Marking/ Rubber Ring Joints All Special Such As Bends,Tee, Reducers Etc.21/2 Pipe , Providing And Fixing Pvc Drenej Pipes Line Including All Fitting Such As Bends ,Tee, Reducers Support Etc 6 Pipe , Providing And Fixing Pvc Drenej Pipes Line Including All Fitting Such As Bends ,Tee, Reducers Support Etc 11/2 Pipe , Providing And Fixing Pvc Rain Water Pipes Including All Fitting Such As Bends ,Tee, Reducers Support Etc 4 Pipe , Providing And Fixing Pvc Ac Drenej Pipes Line Including All Fitting Such As Bends ,Tee, Reducers Support Etc 3/4 Pipe , Providing And Fixing Pvc Floor Trap 110×75 Mm Self Cleansing With Or Without Went Arm Inlet Receiving Cap For Inlet Dia 50And 40 Mm Complete Including Cutting And Marking Good Wall And Floor , Providing And Constricting With First Class Bricks In Cement Mortar 23 Cm Wall Of Inspection Chamber Laid Over A Bed Of Cement Concrete Inside Plastering Thick With Cement Morter Finished With Floating Coat 24×24 Size Including Providing C.I Man Hole Cover With Frame , Providing And Constricting With First Class Bricks In Cement Mortar 23 Cm Wall Of Inspection Chamber Laid Over A Bed Of Cement Concrete Inside Plastering Thick With Cement Morter Finished With Floating Coat 18×18 Size Including Providing C.I Man Hole Cover With Frame , Providing And Fixing Brass Ball Valves Having Pressure Rating Of 20 Bar Make Molotov Or Equivalent 2 Size , Providing And Fixing Brass Ball Valves Having Pressure Rating Of 20 Bar Make Molotov Or Equivalent 11/2 Size , Providing And Fixing Pvc Rigid Water Storage Tank Of 2000 Ltr. Of Sintex And Shakti, Plasto, Supreme Make At All Heights And Level ,,Make Including All Necessary Fixing , Wall Mounted P Trap Water Closet Providing And Fixing In Position First Quality European Type Standard Wall Mounted Model No. Sls-Wht 6953 Including Heavy Solid Plastic Seat Cover With Rubber Buffer Flap Cover , Providing And Fixing Gabriet Or Equivalent Type Plastic Concealed Cistern With Dual Flush 6/3 Ltr Including Water Supply Connection Code No.110.121.00.1 , Concealed Type Flush Control Plate Of Gabriel Make Model No .115.045.21.3 , Providing And Fixing In Position White Under Counter Wash Basin Of Jaqwar Make Model No Fnswht-.40701 Or Equivalent Of Approved Quality With Jaquar Make Series Waste Coupling Model No. 709 Bottle Trap Model No. Acd7696-300×190 Connection Pipes , Providing And Fixing Two Way Bib Cock Model No. Opp-Chr-15041 Of Jaqwar , Providing And Fixing Health Faucet Of Jaqwar Model No. 573 , Providing And Fixing Basin Mixer Model No. Opp-150053 Of Jaqwar , Providing And Fixing Angel Stop Cock Of Jaqwar. Make Continental Seris Model No. 053 Kn , Providing And Fixing Single Lever Diverter Exposed Parts Kit Of Jaqwar Make Opel Prime Series Model No.Opp-15079Nkpm , Providing And Fixing Concealed Body For Single Lever Diverter Of Jaqwar Make Model No.Ald-Chr-079N , Providing And Fixing Overhead Shower Shower Arm Model No.Shp479l450 Ohs-Chr-1603 , Providing And Fixing Bathtub Spout And Hand Shower Of Jaqwar Make Model No.Spj-Chr-15463 , Providing And Fixing Concealed Stop Cock Of Jaqwar Make Model No. 089 ,083 , Providing And Fixing Nahni Trap S.S Jally 6×6 , Providing And Fixing Pressure Pump 1.5 Kg Of Make V Guard , Providing And Fixing Of Storage Heater With Heating Capacity Of 10 Ltr Make Recold Eterno Make Or Equivalent With Necessary Inlet And Outlet With Flexible Pipes , Roofing Removel Of Existing Battens, Asbestos Sheets, Battens, Mangalore Tiles And Fabricated Structure With Acp Sheets , Fabrication Of 2Ft X 2Ft Grid Over The Existing Roof Slab, Iko Cambridge Shingle (30 Year Warranty), Membrane (Asian Paints) 3 Mms, Bitumen Primer, Ridge, 16Mm Fiber Cement Board, Aluminum Drip Edge, Installation, Transport, Handling & Gas , Facia (8Inches) , Upvc Gutters 6Inches
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
28.
Defence #10832999 Price Bid
Tender For Additional / Alternator To Swimming Pool And Other Works Under Age B/R Iii At Chandimandir; 1 Dubbing out average 20mm thick on irregular faces of walls, exposed reinforced surfaces, in Cement and Sand mortar 1:4,including necessary scaffolding & safety arrangement for plaster upto & including 4 storey building complete all as specified. 2 Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. 3 providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate,as in foundations, filling and mass concrete etc., complete all as specified and as directed 4 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. 5 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base finished fair and rough without using extra cement, complete all as specified and directed. 6 Coloured non skid porcelain tiles exterior grade 300x300x 8-10mm thick heavy duty (Endura from Johnson or equivalent) as in floor, set and jointed in neat slurry and pointed in coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in cement mortar 1:6, complete all as specified and directed 7 Glazed coloured ceramic tiles in vertical surface 300mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. 8 Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, including 15mm thick in cement mortar 1:6, complete all as specified and directed 9 Coloured vitrified ceramic tiles, 10mm thick (square/rectangular ) , area of each tiles exc 0.18 Sqm but n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 10 20mm thick Granite work (of any type table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in, set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite compelte all as specified and directed. 11 Kota Stone Slab flooring, 18-20mm thick, best quality over and including cement screed bed 15mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including cutting, rubbing, grinding and polishing (Mirror finish) complete all as specified and directed. 12 Factory made machine pressed, pre polished, coloured chequered cement concrete tiles 250mm x 250mm x 20-22mm thick (with grey cement and no pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 13 Plain cement mortar 1:3:6 (type C-2 using 20mm graded aggregate), 75mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement,all as specified.Note: 10mm construction joint will be provided and panel should not be more than 3metre in length and joint filled with filler bitumen and sand in ratio (1:3) 14 Two coats of oil bound distemper on wall surfaces over a coat of primer including preparation of new plastered surfaces complete all as specified and directed 15 Preparation of new plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed. 16 Applying Two or more coats on new plastered surfaces of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paintof required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. 17 Prepartion of new surface and applying two coat of premium acrylic emulsion weather proof exterior paint over a coat of primer complete all as specified and directed. 18 Rendering 15mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement, inclunding using water proofing compound complete all as specified.Note : WPC shall be measured and paid separately. 19 Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. 20 Rendering 15mm thickin Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and fair without using extra cement complete, all as specified and directed. 21 PCC 1:3:6 type C-1 (using 20m graded crushed stone aggregate) as in roof padding, finished fair and even without using extra cement, complete all as specified and directed. 22 15mm thick (average thickness) rendering on roof surfaces inclduing flashings and junction of parapets etc finished even and fair in cement mortar 1:4 using water proofing compound as per manufacturers instruction after brushing cement slurry complete all as specified and directed 23 Supply only integral water proofing compound complete all as specified & directed. 24 3mm thick Atactic polypropylene polymer (APP) modified prefabricated water proofing membrane, based polymeric membrane minimum weighing 3kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions and finished, complete all as specified & directed. 25 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete allas specified and directed. 26 Factory made steel window box type with side hung shutters including box type hinges and oneshop coat of red oxide primer, 125mm steel handle-02 Nos mild steel ISI marked tower bolt 125mm size (minimum 2 for each shutter) complete with glazing bars, dovetailed or welded fixed with and including MS flat of suitable size for fixing grills and guards bars etc , complete all as specified. 27 Sheet glass 4mm thick, ordinary quality and glazing with oil putty in square, area not exc 0.5 sq. mtr in each pane,complete all as specified and directed. 28 Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,including filling of PCC 1:3:6 in hollow frame complete all as specified and directed. 29 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressuretreated, all as specified and directed. 30 Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). 31 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge 32 Butt hinges 100mm size, of extruded aluminum alloy with galvanisedmild steel hinge pin, anodised, type C-21, complete all as specified and directed. 33 200 mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. 34 150 mm extruded aluminium handles cast typecomplete all as specified and directed. 35 Aluminum alloy, anodized, sliding door bolt 250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed. 36 Factorymade fixed type steel ventilator with glazing bar compelte all as specified and directed. 37 Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples, complete all as specified and directed. 38 preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 39 Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. 40 Two coats of synthetic enameled paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. 41 Two coats of synthetic enamel paint over priming coat onnew stone and concrete surfaces of any description not otherwise described over 10 cm width or girth including preparation of new surfaces complete all as specified 42 Hollow PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and directed(Note : Colour/design and pattern shall be as decided by the GE) 43 Providing & fixing hangers of 6 mm dia. aluminium (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snapgrid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick nonasbestos fibre cement building boardsfixed in aluminium framework with screws, complete all as specified and directed 44 Providing & fixing hangers of 6 mm dia. aluminium (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snapgrid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick nonasbestos fibre cement building boardsfixed in aluminium framework with screws,fixed as in repair complete all as specified and directed 45 Rolled sections as in main and cross beams, hip and jack rafters,purlins where connectedto common rafters and running rails and guidesforsliding doors, fixedwithangle cleats or other connecting plates, conforming to Fe-290 Gde E165, all as specified and directed. 46 Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O or Fe-310-O all as specified and directed. 47 Mild steel framed work as in doors or gates of angles or other sections with gusset plates complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging or sliding with including hooks and hinges (excluding of covering steel sheeting) fastening, locking arrangement, etc conforming to Fe-410-O or Fe-310-O including dismantling old iron all as specified and directed. 48 Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified & directed by Engineer-in-Charge 49 Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and directed. 50 TMT bars for reinforcement, 6 to 8mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge. 51 Pre-painted galvalume aluminium zinc (AZ-70) coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc , complete all as specified & directed by Engineer-in-charge. 52 Powder coated aluminium(minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge, including making good dismantled portion with PCC (1:2:4) type B-1 in CM 1:3 complete all as specified and directed. 53 5.00mm thick ordinary quality tinted glass,fixed to aluminum frame workin panels exc 0.5 Sqm in each pane, complete all as specified & directed. 54 Door closer hydraulically regulated aluminum (die cast) body, designation No 2, universal type, suitable for door shutters of 701mm to 850mmin width and of weight between 36 to 60 Kg,complete all as specified and directed. 55 Demolition of cement concrete (unreinforced) any description and in any position complete all as specified. 56 Demolition of stone slabs and tiles of any description or thicknessin floors laid, bedded and pointed in any mortar complete all as specified and directed. 57 Surface dressing n.exc 15cm deep in hard dense soil complete all as specified and directed 58 Hard core ofbroken stone or boulders of gauge of guage n.exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 59 Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as speciied and directed. 60 Cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. (Cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately). 61 Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified. 62 Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. 63 Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. 64 Reinforced cement concrete, 1:1½:3(nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in beams, cantilevers , bressumers,lintels over 1.5m span, all as specified and directed . (reinforcement shall be measured and paid for separately). 65 Reinforced cement concrete, 1:1½:3(nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in chajja and the like, complete all as specified and directed (reinforcement shall be measured and paid for separately). 66 Material and labour form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. 67 Form work to chullah hoods, chajjas and similar items including edges / sides and soffits of lintelsetc rough finished surface of concrete flat complete all as specified and directed. 68 Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete, all as specified. 69 Dismantling floor hearth or wall tiling including cementmortar bedding (but not backing) removing serviveable tiles to store and rubbish off the premises complete all as specified and directed 70 Taking down shutter of any description exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed. 71 12mm thick toughned glassas in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holeswith necessary screws/ beading, rubber packing, L patch bottom and top, self closing patch etc,complete all as specified and directed.NOTE : Decoratiion/Design or unit name, emblem, crest over glass shutter will be approved by Engr-in-Charge before executionand the rates are inclusive of the same 72 Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. 73 300 mm long stainless steel handle, fancy type , fixed to toughened glass, complete all as specified and directed. 74 Stainless steel lock for 10-12mm thick glass door, having knob inside with three keys, satin finish, complete all as specified and directed. 75 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. 76 Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. 77 All as per serial item 76 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed 78 All as per serial item 76 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 79 All as per serial item 76 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area) cable as earth continuity conductor 80 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 81 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 82 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. 83 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 84 Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 85 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 86 Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 87 LED lamp9 watts, B-22 type complete all as specified . 88 Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCBs ,MCBs etcand removing from site, Complete all as specified and directed . 89 MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 90 Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . 91 TPN distribution board double door flush mounting with provisions for MCB TPN 6 way, 415 volts having IP 43 protection Complete all as specified and directed . 92 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. 93 MCB, DP, 240 volt,32Amps, 10 KA , B series including connection with suitable size aluminium / copper lugs complete all as specified and directed 94 MCB, SP, 240 volt,40 to 63Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 95 MCB SP , 240 volt, 6Amps to 32Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 96 MCB , TPN/FP 40 to 100 Amp 415 volts, 16 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 97 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one SP 20 Amp MCB complete all as speicified and directed. 98 Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and provision of flexible copper cable 3 core from ceiling rose tofan complete all as specified and directed. 99 LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed. 100 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completecomplete all as specified and directed. 101 LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete fixed as in repair complete all as specified and directed. 102 LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed. 103 Exhaust fan energy efficient metallic blades heavy duty turbo force of size 300mm sweep, 1400 rpm, AC 230 volts complete with louvers shutters mounting on wall with holding down bolts, nuts, washerscomplete all as specified and directed. 104 Wall mounted fan PVC body, 400mm sweep, 230 volt , AC,quick start torque motor with copper winding complete all as specified and directed. 105 LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size ncluding taking down any type ceiling fittingcomplee all as specified and directed. 106 LED flood light fitting 100 Watt 6500K outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrision resistantincluding thermal management in multiple optics complete with IP 65 protectioncomplete all as specified and directed. 107 Suface mounting back lit LED 1 x 4 tile in CRCA housing with full opel diffuser for soft & glare free distribution panel with surge protection complete including cutting hole of required size in POP/false ceiling making good disturbedincluding taking down any type ceiling fittingcomplee all as specified and directed. 108 Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. 109 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.NOTE: (i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth 110 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. 111 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), completeall as specified and directed. 112 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed. 113 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection,complete all as specified and directed. 114 XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 3.5core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. 115 32mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
29.
Housing Urban and Rular Development #10831693 Price Bid
Tender For Interior Furnishing Work For School At Vanakbara Bus Stop And School Near Vadlimata Temple At U.T. Of Diu-2 Round stage_ Music room Provide and install a 3000 mm in diameter and 300 mm high, circular stage supported by 50 x 50 mm thick teakwood supports, as per the sizes mentioned in the drawing. The top surface consists of a backing 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick teakwood planks finished with one coat of lacquer and two coats of matte/satin/glossy melamine polish as per the approved sample. The plywood and teakwood planks were fixed to the teakwood frames. The sides are covered with 12 mm thick BWP flexible plywood (Green Ply, Everest or of equivalent make) and 12 mm melamine-polished teakwood beading. Heavy-duty plastic moulded buffers are to be provided at the bottom of the approved wooden supports. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 3 Working table_CCTV roomProvide and install the working table, made of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) on the tabletop and bottom supports, and 12 mm thick BWP plywood for drawers as per the sizes mentioned in the drawing. The tabletop surface to be finished with 1mm thick anti-scratch laminate, all the external surfaces to be finished with 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make), and internal surfaces and drawers to be finished with 0.8 mm thick off-white liner laminate (Century, Green Lam, Royal Touché or of equivalent make) as per the approved sample.All the edges will have 10 mm thick melamine-polished teakwood beading. The study table will include locks and drawer channels fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make).The drawer shutter will have recessed handles (details as per the drawing). Table will include cable management port and ventilation opening as specified in the drawing. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 4 Working table_Accounts room Provide and install the working table, made of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) on the tabletop and bottom supports, and 12mm thick BWP plywood for drawers as per the sizes mentioned in the drawing. The tabletop surface to be finished with 1 mm thick anti-scratch laminate, all the external surfaces to be finished with 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make), and internal surfaces and drawers to be finished with 0.8 mm thick off-white liner laminate as per the approved sample. All the edges will have 10 mm thick melamine-polished teakwood beading. The study table will include locks and drawer channels fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). The drawer shutter will have recessed handles (details as per the drawing). Table will include cable management port and ventilation opening as specified in the drawing.All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 5 Working table–‘a’_Computer lab tableProvide and install the table, using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). The support structure consists of 19 mm thick plywood, vertical and horizontal teakwood supports. Heavy-duty plastic moulded buffers to be provided at the bottom of supports. All the external and internal surfaces to have 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) with one coat of lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the edges will have melamine-polished teakwood beading. Table will include cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 6 Working table–‘b’_Social science lab table / Science lab tableProvide and install the table, using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). The support structure consists of 19 mm thick plywood, vertical and horizontal teakwood supports. Heavy-duty plastic moulded buffers to be provided at the bottom of the wooden supports. Provide 75-125µm functional powder-coated (Asian, ICA, or equivalent make) MS- ‘L’ angle as per size mentioned in drawing, with horizontal teakwood frame to support tabletop. All the external and internal surfaces have a 4 mm thick veneer with one coat of lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the edges have melamine-polished teakwood beading. Table will include cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 7 Working table– ‘c’_lab teacher’s table/lab discussion table/library discussion table Provide and install the table using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) on the table top and 19 mm thick BWP Plywood as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). The support structure consists of 19 mm thick plywood, vertical and horizontal teakwood supports. Heavy-duty plastic moulded buffers to be provided at the bottom of the wooden supports. Provide 75-125µm functional powder-coated (Asian, ICA, or equivalent make) MS- ‘L’ angle as per size mentioned in drawing, with horizontal teakwood frame to support tabletop. All the external and internal surfaces have a 4mm thick veneer with one coat of lacquer and approved melamine polish. All the edges have melamine-polished teakwood beading. Table will include cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 8 Working table–‘d’_Social science lab table / NCC roomProvide and install the table, using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). The support structure consists of 19 mm thick plywood, vertical and horizontal teakwood supports. Heavy-duty plastic moulded buffers to be provided at the bottom of supports. All the external and internal surfaces to have 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) with one coat of lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the edges will have melamine-polished teakwood beading. Table will include cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 9 Working table– ‘e’_Classroom teacher’s table / Staff room tableProvide and install the table using 25 mm and 19 mm thick BWR plywood (IS: 710 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). The support structure consists of 19 mm thick plywood, vertical and horizontal teakwood supports with one coat of lacquer and two coats of matt/satin/glossy finish melamine polish as approved by the architect, heavy-duty plastic moulded buffers to be provided at the bottom of supports. All the external and internal surfaces to have 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) with approved melamine polish. Table will include cable management port and ventilation opening as specified in the drawing. All the edges will have melamine-polished teakwood beading. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 10 Working table– ‘f’_Instructor cabin table + Side storageProvide and install the table, using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). Supports and drawers to be made of 19 mm and 12 mm thick plywood. Heavy-duty plastic moulded buffers are to be provided at the bottom of the plywood, while the 45° niche drawer handle edge will have 2 mm PVC beading of Rehau polymers or an equivalent make with a similar shade of approved polish. All the external surfaces have 4 mm thick veneer with one coat of lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the internal surfaces of the drawers will have 0.8 mm thick off-white liner laminate as per the approved sample. All the edges have melamine-polished teakwood beading. Provide 75-125µm functional powder-coated (Asian, ICA, or equivalent make) MS- ‘L’ angle as per size mentioned in drawing, with horizontal surface of plywood to support the tabletop. The table includes cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 11 Working table–‘g’_HM room table + Side storageProvide and install the table, using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). Supports and drawers to be made of 19 mm and 12 mm thick plywood. Heavy-duty plastic moulded buffers are to be provided at the bottom of the plywood, while the 45° niche drawer handle edge will have 2 mm PVC beading of Rehau polymers or an equivalent make with a similar shade of approved polish. All the external surfaces have 4 mm thick veneer with one coat of lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the internal surfaces of the drawers will have 0.8 mm thick off-white liner laminate as per the approved sample. All the edges have melamine-polished teakwood beading. Provide 75-125µm functional powder-coated (Asian, ICA, or equivalent make) MS- ‘L’ angle as per size mentioned in drawing, with horizontal surface of plywood to support the tabletop. The table includes cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 12 Working table– ‘h’_Admin room workstationProvide and install the table using 25 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The tabletop consists of 25 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make). Supports and drawers to be made of 19 mm and 12 mm thick plywood. Heavy-duty plastic moulded buffers are to be provided at the bottom of plywood supports. All the external and surfaces have 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) with one coat of lacquer and approved melamine polish. All the internal surfaces of the drawers will have 0.8 mm thick off-white liner laminate as per the approved sample. All the edges will have melamine-polished teakwood beading. The table includes cable management port and ventilation opening as specified in the drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 13 Working table– ‘i’_Conference room tableProvide and install the table using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 25 x 25 mm MS box section, 5 mm thick MS plate, and an MS ‘C’ channel as per the sizes mentioned in the drawing. The tabletop consists of 19 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), with 10mm thick melamine-polished teakwood beading on edges. The table is supported by 75-125µm functional powder-coated MS box section frame MS base plate support as per detailed drawing. MS plate supports including 75 mm diameter MS pipe and heavy-duty plastic-moulded buffers to be provided at the bottom. All MS frame surfaces are covered with 12 mm thick plywood and 4mm thick veneer with one coat of lacquer and two coats of matte/satin/glossy finish melamine polish as approved by the architect. Provision for pop up switchboard, cable management port and ventilation opening is to be included as specified in the drawing. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 14 Faculty dining table Type-jProvide and install a table using 25mm thick BWP plywood (IS:710 Grade of Century, Green ply, Everest or of equivalent make) for the table top and 6mm thick BWP plywoodfor underside as per sizes mentioned in the drawing. Finish the tabletop with 4mm thick veneer (Century, Green panel, Archid, Timex or of equivalent make) and apply one coat of lacquer and two coats of matte/satin/glossy finish melamine polish as approved by the architect. All the edges will have 6mm melamine-polished teakwoodbeading. The table will be supported with vertical wooden members and wooden frame below the table top finished with melamine-polish. The buffer strips to be provided at the bottom of the wooden supports. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 15 Library reception tableProvide and install the ‘L’-shaped table using 19mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The lower and upper tabletop consists 19 mm thick plywood and 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) with one coat of lacquer and two coats of matte/satin/glossy finish melamine polish as approved by the architect. Supports and drawers are to be made from 19mm and 12mm thick plywood. All the internal surfaces of the drawers will have 0.8 mm thick off-white liner laminate. The table includes 75 mm plywood skirting; 45° niche drawer handle with 2mm PVC beading of Rehau polymers or equivalent make with a shade similarto the approved polish. All the external surfaces have a 4 mm thick veneer with lacquer and approved melamine polish, while non-visible surfaces have one lacquer finish coat. All the edges have approved melamine-polished teakwood beading. The table includes cable management port and ventilation opening as specified in the drawing. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 16 Stackable table type- ‘a’Provide and assemble stackable table using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports as per detail shown in the drawing and finish 25 mm thick plywood table top with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix table top and legs as per detail drawing. Edges will have 10 mm thick melamine-polished teakwood beading. Rubber gaskets are provided at the table top base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 17 Stackable table type- ‘b’Provide and assemble stackable table using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports as per detail shown in the drawing and finish 25 mm thick plywood table top with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix table top and legs as per detail drawing. Edges will have 10 mm thick melamine-polished teakwood beading. Rubber gaskets are provided at the table top base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 18 Stackable table type- ‘c’Provide and assemble stackable table using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports as per detail shown in the drawing and finish 25 mm thick plywood table top with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix table top and legs as per detail drawing. Edges will have 10 mm thick melamine-polished teakwood beading. Rubber gaskets are provided at the table top base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 19 Stackable table type- ‘d’Provide and assemble stackable table using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports as per detail shown in the drawing and finish 25 mm thick plywood table top with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix table top and legs as per detail drawing. Edges will have 10 mm thick melamine-polished teakwood beading. Rubber gaskets are provided at the table top base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 20 Curved seating_ Music roomProvide and install curved and circular sitting furniture, as per sizes and shapes mentioned in the drawing, supported by teakwood frame supports. The top surface consists of a backing of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make), covered with 75 mm foam. Sides will be covered with 25 mm thick foam on 12 mm thick BWP flexible plywood (Green Ply, Everest or of equivalent make). The top and sides is to be finished with the selected fabric. The lower edge of the sitting area will be framed with 6 mm thick plywood for fabric fixation. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 21 Circular seating_ Music roomProvide and install curved and circular sitting furniture, as per sizes and shapes mentioned in the drawing, supported by teakwood frame supports. The top surface consists of a backing of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make), covered with 75 mm foam. Sides will be covered with 25 mm thick foam on12 mm thick BWP flexible plywood (Green Ply, Everest or of equivalent make). The top and sides is to be finished with the selected fabric. The lower edge of the sitting area will be framed with 6 mm thick plywood for fabric fixation. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 22 Seating outside computer labProvide and install column to column seating, supported by MS supports as per the detailed drawing. The top surface consists of teakwood planks fixed on 19 mm thick plywood BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make), supported by four brackets fabricated from 8 mm MS plates, as per design. Additionally, one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood planks and beading shall cover the MS supports with a seamless finish. All materials include adhesives and hardware must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 23 Waiting area seating_ Admin roomProvide and install a wall-to-wall seat, supported by MS supports as per the detailed drawing. The top surface consists of teakwood planks fixed on 19 mm thick plywood BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make), supported by 75-125µm functional powder-coated MS box sections and four brackets fabricated from 8 mm MS plates, as per design. Additionally, one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood planks and beading shall cover the MS box sections with a seamless finish. All materials include adhesives and hardware must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 24 Library racks type-‘a’ Provide and install a library rack using 8 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. All the external and internal surfaces have 4mm thick veneer with one coat of lacquer and two coats of matte/satin/glossy finish melamine polish as approved by the architect. All the edges have approved melamine-polished teakwood beading as per detailed drawing. The rack includes 75-125µm functional powder-coated MS name plates bolted onto shelves as per detailed drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 25 Library racks type-‘b’Provide and install a library rack using 8 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. All the external and internal surfaces have 4mm thick veneer with one coat of lacquer and two coats of matt/satin/glossy finish melamine polish as approved by the architect. All the edges have approved melamine-polished teakwood beading as per detailed drawing. The rack includes 75-125µm functional powder-coated MS name plates bolted onto shelves as per detailed drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 26 Type-c (single side racks)Provide and install a library rack using 8 mm and 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. All the external and internal surfaces have 4mm thick veneer with one coat of lacquer and two coats of matte/satin/glossy finish melamine polish as approved by the architect. All the edges have approved melamine-polished teakwood beading as per detailed drawing. The rack includes 75-125µm functional powder-coated MS name plates bolted onto shelves as per detailed drawing. A sample must be approved before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 27 Cupboard_Instructor’s cabin + seatProvide and install the Cupboard made of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The cupboard comprises two closed units separated by open shelves. The sides, bottom, shutter, and shelves are to be made of 12 mm, 19 mm and 25 mm thick plywood and back side to be made of 8 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate and all the external surface will have 1mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make), as approved by the architect. All the internal shelf edges will have 10 mm thick approved melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels and magnet fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). The shutter will have recessed handles and 8 mm Saint Gobain glass with flat edges to be fixed with a teakwood frame using silicon and teakwood beading as per the drawing. Additionally, a seating space as detailed in the drawing is featured at the back of the cupboard, assembled from 19 mm and 25 mm plywood (IS: 710 Grade of Century, Green Ply, Everest, or of equivalent make). This seating will be covered with 10 mm thick teakwood beading and 1 mm laminate (Century, Green Lam, Royal Touché or of equivalent make), as per selection. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC).All sizes as indicated in drawings. 28 Cupboard _ CCTV roomProvide and install an ‘L’-shaped cupboard made of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, bottom, shutter, and internal shelves are to be made of 12 mm, 19 mm, and 25 mm thick plywood and back side to be made of 8 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate and all the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make), as approved by the architect. All the internal shelf edges will have 10 mm thick approved melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). The shutter will have recessed handles and 8 mm Saint Gobain glass with flat edges to be fixed with a teakwood frame using silicon and teakwood beading with location and size as per the drawing. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 29 Cupboard _ Accounts room Provide and install a cupboard, made of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, bottom, shutter, and internal shelves are to be made of 12 mm, 19 mm and 25 mm thick plywood and the back side is to be made of 8 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate and all the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. All the internal shelf edges will have 10 mm thick approved melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnet fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). The shutter will have recessed handles and 8 mm Saint Gobain glass with flat edges to be fixed with a teakwood frame using silicon and teakwood beading with location and size as per the drawing. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 30 Cupboard types_Sports RoomProvide and install a cupboard, made in three parts using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matt/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, back, bottom, shutter, and internal shelves are to be made of 12 mm and 19 mm thick plywood. All the internal surfaces will have 0.8 mm thick liner laminate of VIR laminates (SF2001 off white), and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing. The center part of the cabinet includes drawer with veneer finish.All the internal shelf edges will have melamine-polished 10 mm thick teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). This also will include installing a writing board assembly, comprising a white board, niche for smart LCD and duster holder. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). 31 Cupboard types ‘a’_Admin roomProvide and install a cupboard, made with 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, back, bottom, shutter, and internal shelves are to be made of 12 mm and 19 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutter will have 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 32 Cupboard types ‘b’_Staff roomProvide and install a cupboard, made in two parts using 19 mm thick BWR plywood (IS: 710 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matt/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, back, bottom, shutter, and internal shelves are to be made of 12 mm and 19 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 33 Cupboard types ‘c’_Staff room / Atal Tinkering LabProvide and install a cupboard, made in two parts using 19 mm thick BWR plywood (IS: 710 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matt/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, back, bottom, shutter, and internal shelves are to be made of 12 mm and 19 mm thick plywood. All the internal surfaces will have 0.8 mm thick liner laminate of VIR laminates (SF2001 off white), and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have melamine-polished 10 mm thick teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 34 Cupboard types ‘d’_LibraryProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 35 Cupboard types ‘e’_Conference roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 36 Cupboard types ‘f’_Conference roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 37 Cupboard types ‘g’_Conference roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 38 Cupboard types ‘h’_Conference roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 39 Cupboard types ‘i’_Staff roomProvide and install a cupboard, made in two parts using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), according to the sizes of shelves mentioned in the drawing, with teakwood shutters on top finished with one coat of lacquer and two coats of matte/satin/glossy melamine-polish, as approved by the architect. The sides, back, bottom, lower shutters, and internal shelves are to be made of 12 mm and 19 mm thick plywood, as mentioned in the drawings. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnet fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 40 Cupboard types ‘j’_Admin roomProvide and install a cupboard, made in two parts using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polished teakwood shutters and shelves according to the sizes mentioned in the drawing. The sides, back, bottom, shutter, and internal shelves are to be made of 12 mm and 19 mm thick plywood. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 41 Cupboard types ‘k’_Staff roomProvide and install a cupboard, made in two parts using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), according to the sizes of shelves mentioned in the drawing, with teakwood shutters on top finished with one coat of lacquer and two coats of matte/satin/glossy melamine-polish, as approved by the architect. The sides, back, bottom, lower shutters, and internal shelves are to be made of 12 mm and 19 mm thick plywood, as mentioned in the drawings. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The lower shutter will have polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make), recessed handles, while the upper shutter includes 8 mm Saint Gobain glass with flat edges, fixed with a teakwood frame using silicon and teakwood beading as per detailed drawing.All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnet fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 42 Cupboard types ‘l’_Admin roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing. All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 43 Cupboard types ‘m’_Staff roomProvide and install a cupboard using 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) and 12 mm thick plywood for shelves according to the sizes mentioned in the drawing. All the internal surfaces will have 0.8 mm thick off-white liner laminate, and the external surfaces will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), as approved by the architect. The shutters will be finished with one coat of lacquer and two coats of matte/satin/glossy finish melamine- polished 4 mm thick veneer (Century, Green Panel, Archid, Timex, or of equivalent make) and will have recessed handles as per detailed drawing.All the internal shelf edges will have 10 mm thick melamine-polished teakwood beading. The cupboard will include locks, stoppers, hinges, powder-coated MS pipe, drawer channels, and magnate fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 44 Kitchen / pantry / Toilet / Lab: Under the counter cabinet :Provide and install the under the counter cabinet, made of 19 mm thick and 12 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The shutters and side supports are to be made with 19 mm thick plywood and 12 mm thick plywood to be used in the rear. All the external surfaces to have 1 mm thick laminate (Century, Green Lam, Royal Touché or equivalent make), as approved by the architect. All the internal surfaces to have 0.8 mm thick off-white laminate, as approved by the architect. The cabinet will include hinges and magnet fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). The cabinet shutter will have bare aluminium finish profile handles of the approved make. A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 45 Kitchen / pantry: Under the counter drawerProvide and install the under the counter drawer, made of 19 mm thick and 12 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make) as per the sizes mentioned in the drawing. The shutters are to be made with 19 mm thick plywood and 12 mm thick plywood to make the drawer boxes. All the external surfaces to have 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make) and all the internal surfaces and drawers to have 0.8 mm thick off-white laminate, as approved by the architect.The drawers will have channels fixed with necessary hardware (Hettich, Hafele, Blum, Ozone, or of equivalent make). Drawer shutters will have bare aluminium finish profile handles of the approved make. A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 46 Writing Board (Type -a )Provide and install a writing board assembly, comprising a white board and green sliding board using 19 mm and 12 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) with teakwood framing and aluminium sliding channels as per the sizes mentioned in the drawing. The assembly includes 8 mm thick frosted glass (etched finish with grid lines) with two coats of green enamel paint, framed with 38 mm wide sliding aluminium sections and polished teakwood beading along all edges. Provide a fixed white magnetic board (Alkon or of equivalent make) according to the sizes mentioned in the drawing. Necessary heavy-duty hardware shall be used for securing the aluminium sliding assembly. All the external surfaces to have 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make) and all the teakwood polished with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polish as approved by the architect. All the edges have approved 12mm thick melamine-polished teakwood beading as per detailed drawing. Additionally, fix the LCD TV as directed by the concerned department. The contractor shall package, transport, and install the LCD TVs, ensuring damage – free delivery. The scope encompasses timely completion, compliance with client instruction, a smart LCD stand on the back wall, chalk and duster holders, necessary studs, fasteners, and hardware. A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 47 Writing Board (Type -b)Provide and install a writing board assembly, comprising a white board, niche for smart LCD and duster holder using 19 mm and 12 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) as per the sizes mentioned in the drawing. The assembly includes teakwood frame and 12 mm thick melamine-polished teakwood beading with white magnetic board (Alkon or of equivalent make) according to the sizes mentioned in the drawing. All the external surfaces to have 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make) and all the teakwood polished with one coat of lacquer and two coats of matte/satin/glossy finish melamine-polish as approved by the architect. Additionally, fix the LCD TV as directed by the concerned department. The contractor shall package, transport, and install the LCD TVs, ensuring damage – free delivery. The scope encompasses timely completion, compliance with client instruction, a smart LCD stand on the back wall, chalk and duster holders, necessary studs, fasteners, and hardware. A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 48 Lectern/PodiumProvide and install a Lectern as per size mentioned in the drawing using 19 mm and 12 mm thick plywood (IS: 710 Grade of Century, Green Ply, Everest, or of equivalent make). The cabinet is divided horizontally into two parts. The cabinet is made with 12 mm thick plywood shutters. The external surface will have 1 mm thick laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect, and internal surfaces of plywood are polished with one coat of lacquer. The longer shutters shall be provided with PVD/ZINC-coated SS D-shaped handles with mortice lock externally and tower bolt internally on the opposite shutter. The shorter shutters shall be given aluminium knobs. 75-125µm functional powder-coated MS SHS (size mentioned in drawing) is to be provided at the all the corners and in the center of the total height. Melamine-polished teakwood beading is to be provided as shown in drawing. Table will include cable management port and ventilation opening as specified in the drawing. A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 49 Map Stand _Social science labAssemble a freestanding stand using 50 x 50 mm MS SHS, 5 mm thick MS plate and 5 mm thick solid bar as per the sizes mentioned in the drawing. Provide 600 mm wide support with rubber strips at the bottom fabricated with 50 x 50 mm MS SHS and 5 mm thick MS plate. Integrate 5 mm thick metal hooks, welded into the vertical supports of the stand as a map holder. Finish metal welds with grinding and sanding. Apply 75-125µm functional powder-coated for a durable and scratch-resistant finish. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 50 Stackable stool type-’a’ Provide and assemble stackable stool using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports and 25 mm thick plywood seating with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix seating top and legs as per detail drawing. Edges will have melamine-polished 10 mm thick teakwood beading. Rubber gaskets are provided at the seating base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 51 Stackable stool type-’b’ Provide and assemble stackable stool using 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make), 8 mm thick MS plate, 15 x 15 mm MS SHS and teakwood as per the sizes and shapes mentioned in the drawing. Fabricate legs by bending and appropriate welding of MS plate and Box sections, finishing with grinding and sanding. Apply 75-125µm functional powder-coating for a durable and scratch-resistant finish. Include teakwood buffers at the bottom of the supports, as per detail shown in the drawing and 25 mm thick plywood seating with 1 mm laminate (Century, Green Lam, Royal Touché, or of equivalent make), approved by the architect. Fix seating top and legs as per detail drawing. Edges will have melamine-polished 10 mm thick teakwood beading. Rubber gaskets are provided at the seating base for stacking. A sample will have to be made for approval before mass execution of the work. All materials and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 52 Chair type - 1Provide and install a rocking chair made of glass-reinforced concrete of approved make as per sizes mentioned in the drawing. The chair’s seating, hand rest and backrest shall be moulded in glass-reinforced concrete as one single entity, with pigment approved by the architect. The chair features rounded edges and sealed surfaces for outdoor durability. The support structure consists of an 18° bended MS plate with three coats of synthetic enamel paint of approved shade over a coat of zinc chromate primer, and MS base plate with rubber strips at the bottom as per the detailed drawing. MS plate supports include a compression spring for easy movement.A sample will have to be made for approval before mass execution of the work. All materials, including adhesives and hardware, must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC).All sizes as indicated in drawings.Colour to be approved by the Architect. 53 Chair type - 2 roviding and placing in position ergonomic medium back revolving office chair with AN-70 breathable mesh backrest, single-lock synchro tilt mechanism with tilt tension adjustment, and adjustable lumbar support. Chair to have one-way heightadjustable armrests made of polypropylene, a cushioned seat with high-density PU foam upholstered in fabric, and a sturdy nylon five-star base with twin-wheel castors for smooth mobility. Suitable for long working hours with optimal comfort and posture support. Finish and color as approved by the architect. Make: Featherlite Versa or approved equivalent 54 Chair type -3 Supplying and placing in position ergonomic high back executive mesh chair with integrated headrest, made with IS 20D breathable mesh for enhanced airflow and seating comfort. Chair shall have a multi-lock synchro tilt mechanism allowing multiple reclining positions, and one-way (height adjustable) polypropylene armrests. Seat to be upholstered with high-density PU foam and durable fabric. The base shall be a five-star black nylon structure with twin-wheel castors for smooth movement. Suitable for executive cabins or prolonged work use with ergonomic support. Finish and color as per architect approval. Make: Featherlite Liberate or approved equivalent 55 Chair type -4Supplying and placing ergonomically designed chairs suitable for library and laboratory use, with cushioned seat and back upholstered in durable fabric/leatherette for user comfort during prolonged sitting. Chair to have a strong powdercoated metal sledge base ensuring stability, low maintenance, and non-scratch movement on floor surfaces. Ideal for educational and institutional settings, with available color options including Black, White, Red, Orange, and Green (as approved by architect). Make: Featherlite Loop Cushion or approved equivalent 56 Chair type -5Supplying and placing in position ergonomically designed low back mesh office chair with AC-60 breathable mesh backrest and fabric upholstered high-density cushion seat. The chair shall be fitted with a centre tilt mechanism for basic recline functionality and fixed polypropylene armrests. Base to be made of durable nylon with twin-wheel castors for smooth mobility. Suitable for visitor seating, conference rooms, or short-duration workstations. Finish and color as approved by the architect. Make: Featherlite Smart or approved equivalent 57 Bed_Girls rest room area Provide and install a bed, made of 25 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or of equivalent make) for the bed top, 19 mm thick for supports and 12 mm thick for the bed back according to the sizes mentioned in the drawing. The external surfaces will have the 1 mm thick laminate (Century, Green Lam, Royal Touché or of equivalent make) and all the internal surface will have 0.8 mm thick off-white liner laminate, as approved by the architect.. Edges will have 2 mm PVC beading of Rehau polymers or equivalent make with similar shade of approved laminate. A sample must be approved before mass execution of the work. All materials, including of adhesive and hardware must be approved by the consultant as per the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 58 Pre – Primary school sofaProvide and install rectangular sitting furniture, as per sizes and shapes mentioned in the drawing, supported by teakwood frame supports. The top surface consists of a backing of 19 mm thick BWR plywood (IS: 303 Grade of Century, Green Ply, Everest, or equivalent make), covered with 75 mm foam. Sides will be covered with 25 mm thick foam with rounded edges on 12 mm thick BWP plywood (Green Ply, Everest or of equivalent make). The top and sides is to be finished with the selected fabric. The lower edge of the sitting area will be framed with 6 mm thick plywood for fabric fixation. All materials, including adhesives and hardware, must be approved by the consultant according to the detailed specifications in the drawing and as directed by the Engineer-in-Charge (EIC). All sizes as indicated in drawings. 59 HM Room Sofa / Conference room sofaSEAT FOAM : The seat is made up of PU foam in Density 28 ±2 kg/cu.mtr with an additional top layer of supersoft PU foam in Density 32 ± 2 kg/cu, upholstered with fabric or leatherette.BACK FOAM : The back is made up of PU foam in Density 28 ± 2 kg/cu. mtr with two additional top layer of supersoft foam of density 32±2 kg/cu. mtr, upholstered with fabric or leatherette.UNDERSTRUCTRE : Understructure is made up of 1.2±0.1 cm. thick hot pressed plywood [moisture resistance & termite proof as per IS:303] & pinewood of cross sections devoid of major knots & surface defects. 6 nos. per seat & 3.8mm Dia zigzag spring assembly is mounted over understructure for cushioning purpose.LEG ASSEMBLY : It is a welded Assembly made in Stainless steel (grade SS 202) tube & plate with plastic endcap.Width (W): 206.0 CM. Depth (D): 90.5 CM. Height (H): 85.5 CM. Seat Height (SH): 45.0 CM.Approved make: Godrej, bonton, Geeken or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 60 Student Desk Type - 1Providing, supplying and placing of Desk cum Bench N Seater. Its size shall be 1040x1060x625. Desk-Top Panel-All panels are made from 18mm thick Pre-laminated twin board (E1/P2 GRADE) with PVC edge banding on all sides. The panels have corners rounded for safety usageUnderstructure: All side metal frames and cross connectors are made from combination of 25.4 x1.2 mm thick(approx. 18 SWG) Round ERW tubes ,31.8 x 1.2 mm thick(approx. 18 SWG) Round ERW tubes and 28.6 x 1.2 mm thick(approx. 18 SWG) Round ERW tubes(As per IS:7138) which are welded together. The Welded structures and cross connectors are coated with min. 45 micron thickness of epoxy polyester coating. Back supports which are provided at the rear back are made of 50.8 x 25.4 x 1.2 mm thick(approx. 18 SWG) rectangular ERW tubes(As per IS:7138).The tubes are coated with min. 45 micron thickness of epoxy polyester coating. The storage shelves are made from 0.6 mm thick MS sheet(As per IS:513) fixed below the desk top panel and are coated with min. 45 micron thickness of epoxy polyester coating. Hooks are provided on the vertical side frames on both sides of the desk for hanging bags/bottles. They are made from 2 mm thick MS sheet(As per IS:513) and are coated with min. 45 micron thickness of epoxy polyester coating.The understructure is assembled using M6 trilobular screws(As per DIN 7500)with Zn blue plating.Compact Laminate seat and back panels are assembled using M6 Countersunk Trilobular screws(as per DIN 7500) with Zn Black Plating (As per IS 1573:1986) Spacers Are provided on th top of round tubes for wooden panels fixing. They are made of PP Glass filled (30%)Plastic Caps made of PP copolymer(3530 Grade) are also provided on the rear frames adding more aesthetic value to the product. M6 high tensile TVS make bolt(Class 8.8) with glasss filled nylon level adjustors are provided at the bottom of understructure to take care of unevenness in floor with height adjustment of approx 15mm.Approved make: Godrej, bonton or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 61 Student Desk Type - 2Providing, supplying and placing of Desk cum Bench N Seater. Its size shall be 1140x1095x710.Desk-Top Panel-All panels are made from 18mm thick Pre-laminated twin board (E1/P2 GRADE) with PVC edge banding on all sides. The panels have corners rounded for safety usageUnderstructure: All side metal frames and cross connectors are made from combination of 25.4 x1.2 mm thick(approx. 18 SWG) Round ERW tubes ,31.8 x 1.2 mm thick (approx. 18 SWG) Round ERW tubes and 28.6 x 1.2 mm thick(approx. 18 SWG) Round ERW tubes(As per IS:7138) which are welded together. The Welded structures and cross connectors are coated with min. 45 micron thickness of epoxy polyester coating. Back supports which are provided at the rear back are made of 50.8 x 25.4 x 1.2 mm thick(approx. 18 SWG) rectangular ERW tubes(As per IS:7138).The tubes are coated with min. 45 micron thickness of epoxy polyester coating. The storage shelves are made from 0.6 mm thick MS sheet(As per IS:513) fixed below the desk top panel and are coated with min. 45 micron thickness of epoxy polyester coating. Hooks are provided on the vertical side frames on both sides of the desk for hanging bags/bottles. They are made from 2 mm thick MS sheet(As per IS:513) and are coated with min. 45 micron thickness of epoxy polyester coating.The understructure is assembled using M6 trilobular screws(As per DIN 7500)with Zn blue plating.Compact Laminate seat and back panels are assembled using M6 Countersunk Trilobular screws(as per DIN 7500) with Zn Black Plating (As per IS 1573:1986)Spacers Are provided on th top of round tubes for wooden panels fixing. They are made of PP Glass filled (30%)Plastic Caps made of PP copolymer(3530 Grade) are also provided on the rear frames adding more aesthetic value to the product.M6 high tensile TVS make bolt(Class 8.8) with glasss filled nylon level adjustors are provided at the bottom of understructure to take care of unevenness in floor with height adjustment of approx 15mm.Approved make: Godrej, bonton or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 62 Student Desk Type - 3Providing, supplying and placing of Desk cum Bench N Seater. Its size shall be 1240 x 1130 x 760.Desk-Top Panel-All panels are made from 18mm thick Pre-laminated twin board (E1/P2 GRADE) with PVC edge banding on all sides. The panels have corners rounded for safety usageUnderstructure: All side metal frames and cross connectors are made from combination of 25.4 x1.2 mm thick(approx. 18 SWG) Round ERW tubes ,31.8 x 1.2 mm thick (approx. 18 SWG) Round ERW tubes and 28.6 x 1.2 mm thick (approx. 18 SWG) Round ERW tubes(As per IS:7138) which are welded together. The Welded structures and cross connectors are coated with min. 45 micron thickness of epoxy polyester coating. Back supports which are provided at the rear back are made of 50.8 x 25.4 x 1.2 mm thick (approx. 18 SWG) rectangular ERW tubes (As per IS:7138). The tubes are coated with min. 45 micron thickness of epoxy polyester coating. The storage shelves are made from 0.6 mm thick MS sheet(As per IS:513) fixed below the desk top panel and are coated with min. 45 micron thickness of epoxy polyester coating. Hooks are provided on the vertical side frames on both sides of the desk for hanging bags/bottles. They are made from 2 mm thick MS sheet(As per IS:513) and are coated with min. 45 micron thickness of epoxy polyester coating.The understructure is assembled using M6 trilobular screws(As per DIN 7500)with Zn blue plating.Compact Laminate seat and back panels are assembled using M6 Countersunk Trilobular screws(as per DIN 7500) with Zn Black Plating (As per IS 1573:1986)Spacers Are provided on the top of round tubes for wooden panels fixing. They are made of PP Glass filled (30%)Plastic Caps made of PP copolymer(3530 Grade) are also provided on the rear frames adding more aesthetic value to the product.M6 high tensile TVS make bolt(Class 8.8) with glass filled nylon level adjustors are provided at the bottom of understructure to take care of unevenness in floor with height adjustment of approx. 15mm.Approved make: Godrej, bonbon or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 63 EPDM flooring Multicolour EPDM flooring for Pre school classroom. The interlocking tile to be 500 mm x 500 mm. The thickness of EPDM tile to be 25mm & tensile failure stress of 17MPa. Laying of tile with thin coat of water based adhesive. The sample to be approved by the Engineer in Charge (EIC). 64 RugProviding of the rug for HM rooms of the size 2000 x 3000 and placed as per the location provided by the architect. The rug should have vinyl rubber bottom. The sample to be approved by the architect. 65 Anti-Skid Door MatProviding of the door/rubber mat for boys/girls/handicap toilet placed as per the location provided by the architect. The mat should have anti-skid bottom. The sample to be approved by the architect 66 MDM Roll carpetHand woven reversible 100% natural cotton striped / roll carpet (Blue - Border, 600mm wide x 5m roll), washable, fade resistant, durable and easily foldable. 67 Carpet tile flooringProviding and laying Flotex floor covering (or approved equivalent), a high-performance textile flooring solution suitable for music rooms in schools. The flooring shall be made of dense nylon 6.6 fibers electrostatically flocked onto a waterproof PVC backing, offering excellent durability, acoustic absorption, slip resistance, and ease of maintenance. Flotex shall combine the resilience of a resilient floor with the comfort and acoustic benefits of a textile floor. The material shall be anti-microbial, allergy-friendly, stain-resistant, and suitable for high foot traffic educational areas. Flooring shall be laid with recommended adhesive on a properly prepared subfloor, ensuring neat joints and smooth finish. Color/Pattern: As per architect’s selection 68 Aluminium galvanized wooden finish ceilingProviding and fixing aluminium galvanized ceiling panels in 100mm / 150mm / 200mm width, with wood grain finish (teak/oak/walnut or approved), fixed on concealed GI/aluminium suspension system with all necessary accessories (trims, hangers, fasteners). Panels shall be pre-coated/powder-coated, rust-proof, and suitable for indoor ceiling applications. 69 Acoustic Wall panellingProvide and install acoustic panels as per approved design and sample by Architect. The panels shall feature fabric-wrapped high- density glass wool/wood wool/ combinations of foam and fabric/basophilic elements like cork and moss measuring 600 x 600/1200mm with a thickness of 25-50mm. Fixing of the panelling should be approved by the Engineer-in-Charge (EIC). 70 Ceiling panellingProvide and install medium-density fibreboard(MDF) acoustic panels for slab and wall applications. The perforated panels, manufactured from high-quality MDF with a density of 750-850 kg/cubic meter and thickness of 1 mm ( ½” to 1”), shall have a sound absorption coefficient of 0.5-0.8 and a noise reduction coefficient of 0.55 for a 3.12 sq.m area. The panels measure 190mm x 1190mm with 6mm perforation holes and shall be fixed using aluminium channels and hold clips. The sample must be approved by the Engineer-in-Charge (EIC). 71 Acoustic Baffle and cloud CeilingProvide Rockwool rigid baffles and clouds, manufactured from high-density rock wool, with specifications including: 1200 x 1200mm size, 40mm thickness and a Noise Reduction coefficient (NRC) of 0.9. The baffles and clouds shall be wrapped in a textured finish fabric, offering various colour and fabric options. Fixing shall be done using anchor bolts to secure the baffles to the slab and suspension system for the clouds. Fixing of the panelling should be approved by the Engineer-in-Charge (EIC). 72 Painting work on MS FabricationApply painting work on MS fabrication, including PU coating, touch-ups and surface rubbing to rectify poor finishes. This involves two or more coats of Deluxe Multi Surface Paint to achieve an even shade, applying two or more coats (@0.90 litter/10sqm) over a primer undercoat (@0.80 litter/10 sqm) to achieve an even shade on existing steel columns, following thorough surface cleaning, using materials from approved brands and manufacturers. 73 Roller BlindsProviding and fixing roller blinds with fabric of approved shade and design, mounted on heavy-dutyaluminum roller tube with powder-coated finish. The fabric shall be UV-resistant, dust-repellent, and fade-proof, suitable for interior applications,with smooth rolling action using a chain and clutch mechanism for manual operation. The blinds shall be fixed with appropriate MS/Aluminium brackets, end caps, and fittings for wall or ceiling mounting, as per site condition. Edges of the fabric shall be heat sealed or hemmed to prevent fraying.Material: Polyester fabric / Sunscreen / Blackout fabric (as specified)Color/Shade: As approved by architect 74 Dustbin Type - aProviding of the black finished stainless steel perforated open top waste bin of the size 175 x 250 for classroom, lab, toilets and girls rest room as per the location provided by the architect. The waste bin to be made of NON MAGNETIC SS 200 SERIES Thickness - 0.4 mm, Metallic Elegant look. The waste bin to have anti-slip base. The sample to be approved by the architect. The items shall be in working condition. Approved Make :IKEA, Mofna Industries pvt. ltd. 75 MirrorProviding and fixing bevelled edge mirror of required size and shape as per architectural drawings, made from 5mm thick high-quality float glass with polished bevelled edges (bevel width approx. 18–25mm). The mirror shall be fixed to the wall using concealed fixtures, stainless steel studs/spacers, or adhesive as per site condition, ensuring a secure and flush installation. All necessary fittings and supports shall be included in the scope. Approved Make: Saint-Gobain, Modiguard, or equivalent 76 Toilet paper holdersProviding and fixing wall-mounted toilet paper holder made of corrosion-resistant stainless steel with brushed/matte finish. The design shall be minimal and contemporary, suitable for modern toilet interiors. Holder to be fixed using concealed fasteners for a clean look. All necessary screws, wall plugs, and installation accessories to be included. Suitable for use in residential, commercial, or institutional toilets. Approved Make: IKEA (BROGRUND), Jaquar, Kohler, or equivalent 77 Soap Dispensers and dispenser holderProviding and fixing wall-mounted liquid soap dispenser complete with stainless steel holder, suitable for residential, commercial, or institutional toilets. The dispenser container shall be made of durable acrylic or frosted glass with a hand-operated pump mechanism. The holder shall be fabricated from corrosion-resistant stainless steel (SS 304 or equivalent) with a brushed finish, designed to securely support the dispenser. The unit shall be installed with concealed fasteners and shall include all necessary mounting hardware and accessories. Approved Make: Jaquar, Kohler, or equivalent 78 Wall clockProviding and fixing wall-mounted round analog clock of 380mm diameter (38 cm), with a clear, easy-toreaddial featuring bold hour and minute markings. The clock shall have a durable plastic frame and a front cover made of glass/acrylic,equipped with a silent quartz movement mechanism for smooth and noise-free operation. Battery-operated and suitable for classrooms,offices, or institutional spaces. Color and design as approved by architect. Approved Make: IKEA (Tagged model), Ajanta, or equivalent 79 Type - 1 SignagesSupply & fixing ONE 100mm in height Stainless Steel Cut-out (5mm Thick), displaying classroom number, name of room, etc., complete matter will be Laser Cut from natural SS with Matt Finish & Matt Lacquer, fitting directly on wall with 3M Double-Gum tape 80 Type - 2 SignageSupply & fixing reverseLit channel letter, displayingschool name as per your design in which letter will be 450mm in height, complete with all accessories i.e. 1.5” emboss Stainless Steel Matt Finish (0.8mm Thick) Letters with with Groove cut 25mm Thick Acrylic Letters assembled behind SS Letter, LED’s (Warm White or White), SMPS, L.T.Wire for inside Wiring etc. 81 Type - 3 SignageProviding and fixing of the evacuation diagram, made on acrylic sheet with eco-solvent print. The evacuation diagram to be of the size 297 x 210mm and made from 5mm thick acrylic sheet. The diagram to be printed on the sheet with the eco-solvent print. The diagram to be fixed on the surface with 3M adhesive tape as per the location provided by the architect. Diagram for printing in required format shall be provided by architect. 82 S.S. RailingProviding and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) and as directed by EIC. The rate to include all scaffolding and hoisting charges. 83 100mm foam mattressProviding of the 100mm thick foam mattress of the size 850 x 1700 as per the location provided by the architect. The foam mattress to include the layer of PU foam, a layer of Resitec foam, a layer of double layered quilting foam and a layer of knitted fabric as the top most layer. The sample to be approved by the architect. Approved Make: Sleepwell or equivalent 84 Notice Board: Providing and fixing wall-mounted notice board of size 900mm × 600mm (3 feet × 2 feet), constructedwith 12mm thick soft board mounted on 6mm thick BWR Grade plywood conforming to IS:303 (Century Ply or equivalent). The board surfaceshall be covered with fabric/felt cloth in approved color for pin-up use. The notice board shall be enclosed in a polished hardwood frame andfitted with a hinged front-opening 4mm thick clear glass shutter, complete with brass/SS hinges, magnetic catch, and handle. Suitable forsecure display of notices in educational or institutional spaces. 85 Soft BoardProviding and fixing pin-up soft board of size 2400mm × 1200mm (8 feet × 4 feet), comprising 12mmthick soft board mounted on 6mm thick BWR Grade plywood of IS:303 Century Ply or equivalent. The board surface shall be covered withfabric/felt cloth in approved shade, suitable for classroom and lab use. The board shall be finished with an anodized aluminium frame withmitred corners, fixed flush to wall with concealed fasteners and necessary supports. 86 Smart TVSITC of 65 inch Smart Interactive display true 4K UltraHD (3,840 × 2,160) resolution for outstanding details and stunning visuals. It should be IPS Panel with 3mm-thick toughened glass for added protection against scratches or screen damage, Anti-Glare + Anti-Fingerprint + Antimicrobial. with Pen including all required wall mounting stand and all accessoriesIt must equip front bezel USB-A, USB-C ports for quick connection to USB keyboards/mice, memory drives and data, High-speed Wi-Fi 6 connection, Bluetooth 5.2, Dual RJ45 ports. Brightness 400 cd/m² or above. 20-point touch, 18W x 2 (Stereo), OS Android v13 or above, Speakers: 18W x 2 (Stereo), 32GB Internal memory + 4GB RAMPreloaded software like whiteboard, screen share, screen annotation and recording tools, centralized device management through Remote Manager Cloud or Windows software, Browser, App Store, Media Player. Screen lock, Dual Network Environment. OPS: Intel® i5 Processor Iris® Xe Graphics, 8GB RAM, 256 GB name SSD, 3 nos. USB 3.0 ports,1 HDMI port, 1 DP interface,1 Type-C port, Support dual channel memory, Wi-Fi IEEE 802.11. Windows 11 Pro Licence. ISO 27001 Certified. 3 years warranty of Samsung, LG Panasonic, DELTA 87 Movable Softboard: Suppling, fabricating and installing movable soft board with anodized aluminium frame and high density 12mm thick softboard surface finished with approved fabric of Red/blue/brown/white colour. The Board shall be mounted on smooth castor wheels with locking mechanism for stability ensuring durability and ease of mobility. Dimension 2400 x 1200 with precise fitting and smooth edge for safety. 88 Metal Box Kitchen StorageProviding and supplying grain storage container fabricated from galvanized iron (GI) sheet, suitable foruse in school kitchen store under the Mid-Day Meal scheme. The container shall be made from 22–24 gauge GI sheet, rust-resistant and foodsafe, with a capacity to hold up to 100 kg of food grains (such as rice or wheat). The container shall be of cylindrical or rectangular shape (as approved), with a tight-fitting hinged or lift-off lid to protect contents from moisture, pests, and contamination. All edges shall be folded or crimped for safety and strength. 89 Metal Box Kitchen StorageProviding and supplying grain storage container fabricated from galvanized iron (GI) sheet, suitable foruse in school kitchen store under the Mid-Day Meal scheme. The container shall be made from 22–24 gauge GI sheet, rust-resistant and foodsafe, with a capacity to hold up to 20 kg of food grains (such as rice or wheat). The container shall be of cylindrical or rectangular shape (as approved), with a tight-fitting hinged or lift-off lid to protect contents from moisture, pests, and contamination. All edges shall be folded or crimped for safety and strength. 90 MDM Storage RacksProviding and placing in position storage rack fabricated from mild steel (MS) sections, suitable for the store area of a school kitchen under the Mid-Day Meal scheme. The rack shall be free-standing, made with MS tubular vertical supports and horizontal bracing, and shelves fabricated from 24-gauge (approx. 0.6mm thick) MS sheet, fixed or adjustable as per site condition. The entire structure shall be degreased, pre-treated, and finished with oven-baked powder coating of minimum 50–60 microns in approved color. The rack shall have a minimum of four shelves, with sufficient load-bearing capacity to store grains, containers, and kitchen supplies. All edges shall be smooth and safe to handle.Material: Mild Steel frame with 24-gauge MS sheet shelvesFinish: Powder-coated (min. 50–60 microns) in approved shadeSize: As per drawing / approx. 5–6 height, 3–4 length, 18–24 depth 91 Dish RackProviding and fixing stainless steel dish rack made of SS 304 grade material, designed specifically for use in school kitchens for mid-day meal purposes. The rack shall be multi-tiered to accommodate large plates, glasses, and utensils, with proper drainage and a detachable drip tray to ensure hygiene. The design will include durable, corrosion-resistant stainless steel with smooth, easy-to-clean surfaces and rounded edges to prevent damage to the dishes. The rack shall be wall-mounted or free-standing based on the kitchen layout and shall include all necessary brackets, screws, and hardware for secure installation. 92 WoodProviding and supplying seasoned Indian Teak Wood of approved quality and grade (CP/MP or equivalent), free from warping, cracks, knots, or other defects, with uniform grain and texture. The wood shall be properly kiln/air dried with a moisture content not exceeding 12–14%, suitable for use in premium interior applications such as furniture, panelling, door frames, or customized joinery works. Rate to include loading, unloading, handling, and stacking at site. 93 Wall Table (VB_Bio) 7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns. Worktop is 19mm (+/- 2mm) thickJet Black Granite construction. Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle leg space and 1 no of 600mm wide corner leg space. Master uprights, uprights and height adjustable reagent racks,8 nos of one way LPG gas valves and 5 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 94 Island Table (VB_Bio)4880L X 1540D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 8 nos of 600mm wide 2 shutter 1 drawer units with 6nos of 600mm widemiddle legspace and 2 no of 600mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 4 nos of two way lpg valves and8 nos of stools are considered inthe same table. 14 nos of 6 module plate with 28 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 95 Wall Table (VB_Bio)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction. Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks ,6nos of one way lpg gas valves and 6 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 96 MS Apparatus Storage Cabinet (VB_Bio)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plate. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 97 Wall Table (VB_Physics)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, and electrical trunkings and 6 nos of stools are considered inthe same table. 17 nos of 6 module plate with 34 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 98 Island Table(VB_Physics)4880L X 1540D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 8 nos of 600mm wide 2 shutter 1 drawer units with 6nos of 600mm widemiddle legspace and 2 no of 600mm wide Corner legspace. Master uprights,electrical trunkings and8 nos of stools are considered inthe same table. 22 nos of 6 module plate with 44 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 99 Wall Table(VB_Physics)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns. Worktop is 19mm (+/- 2mm) thickJet Black Granite construction. Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, and electrical trunkings and 6 nos of stools are considered inthe same table. 17 nos of 6 module plate with 34 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 100 Full Height Acid/Corrosive Storage Cabinet(VB_Physics)1000 x 1500 x 486Full Height Acid/Corrosive Storage Cabinet (Resilience). Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 101 MS Apparatus Storage Cabinet(VB_Physics)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plate. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 102 Wall Table(VB_Chemistry)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 6 nos of one way lpg gas valves and 5 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 103 Island Table (VB_Chemistry)4880L X 1540D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 8 nos of 600mm wide 2 shutter 1 drawer units with 6nos of 600mm widemiddle legspace and 2 no of 600mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 4 nos of two way lpg gas valves and8 nos of stools are considered inthe same table. 14 nos of 6 module plate with 28 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 104 Wall Table (VB_Chemistry)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 6 nos of one way lpg gas valves and 5 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 105 MS Apparatus Storage Cabinet(VB_Chemistry)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plate. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 106 Wall Table (VD_Bio)6830L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered3 nos of 750mm wide 2 shutter sink unit including 3 no of PP sinks of size 560x355 with 3 water faucets, 2nos of 1500mm widemiddle legspace and 2 no of 750mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 4 nos of one way lpg gas valves and 6 nos of stools are considered inthe same table. 4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 107 Island Table (VD_Bio)4880L X 1540D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 4 nos of 750mm wide 2 shutter sink unit including 4 no of PP sink of size 560x355 with 4 water faucet, 2nos of 1500mm widemiddle legspace and 4 no of 750mm wide Corner legspace.Master uprights, uprights and height adjustable reagent racks, 3 nos of two way lpg gas valves and8 nos of stools are considered inthe same table,4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 108 Wall Table (VD_Bio) 6830L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered3 nos of 750mm wide 2 shutter sink unit including 3 no of PP sinks of size 560x355 with 3 water faucets, 2nos of 1500mm widemiddle legspace and 2 no of 750mm wide Corner legspace.Master uprights, uprights and height adjustable reagent racks, 4 nos of one way lpg gas valves and 6 nos of stools are considered inthe same table. 4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 109 MS Apparatus Storage Cabinet (VD_Bio)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plate. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 110 Wall Table (VD_Physics)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction. Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, electrical trunkings and 6 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 111 Island Table(VD_Physics)4880L X 1540D X 900H Floor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction. Considered with 8 nos of 600mm wide 2 shutter 1 drawer units with 6nos of 600mm widemiddle legspace and 2 no of 600mm wide Corner legspace. Master uprights,electrical trunkings and8 nos of stools are considered inthe same table. 22 nos of 6 module plate with 44 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 112 Wall Table(VD_Physics)7280L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 6 nos of 600mm wide 2 shutter 1 drawer units with 5nos of 600mm widemiddle legspace and 1 no of 600mm wide Corner legspace. Master uprights, electrical trunkings and 6 nos of stools are considered inthe same table. 12 nos of 6 module plate with 24 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 113 Full Height Acid/Corrosive Storage Cabinet(VD_Physics)1000 x 1500 x 486 Full Height Acid/Corrosive Storage Cabinet (Resilience). Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 114 MS Apparatus Storage Cabinet(VD_Physics)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plat. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 115 Wall Table(VD_Chemistry)6830L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered3 nos of 750mm wide 2 shutter sink unit including 3 no of PP sinks of size 560x355 with 3 water faucets, 2nos of 1500mm widemiddle legspace and 2 no of 750mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 4 nos of one way lpg gas valves and 6 nos of stools are considered inthe same table. 4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 116 Island Table (VD_Chemistry)4880L X 1540D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered with 4 nos of 750mm wide 2 shutter sink unit including 4 no of PP sink of size 560x355 with 4 water faucet, 2nos of 1500mm widemiddle legspace and 4 no of 750mm wide Corner legspace.Master uprights, uprights and height adjustable reagent racks, 3 nos of two way lpg gas valves and8 nos of stools are considered inthe same table,4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 117 Wall Table (VD_Chemistry)6830L X 770D X 900HFloor Based Cabinet with Metal Skirting powder coated withpure epoxy of thickness 40-50 microns.Worktop is 19mm (+/- 2mm) thickJet Black Granite construction.Considered3 nos of 750mm wide 2 shutter sink unit including 3 no of PP sinks of size 560x355 with 3 water faucets, 2nos of 1500mm widemiddle legspace and 2 no of 750mm wide Corner legspace. Master uprights, uprights and height adjustable reagent racks, 4 nos of one way lpg gas valves and 6 nos of stools are considered inthe same table. 4 nos of 6 module plate with 8 nos of 6/16A switch and sockets also maintained in the layout. Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender document Colour to be approved by the Architect. 118 MS Apparatus Storage Cabinet(VD_Chemistry)900W X560D X 2100HMS Apparatus Storage Cabinet with top cover plat.Approved make: Godrej or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 119 Lab Stool/ Drg. Stool- Specification: Size:H:710, Seat:H:550, D:300,Under Structure:-Made up of MS cold rolled close annealed,18G tube. Topmade of 18mm thick pre-laminated particle board. Side edges covered with teak wood beading duly polished. All steel components are epoxy powder coated followed by seven tanks anti corrosion treatment of surface. Approved make: Godrej, bonbon or as specified in the list of approved furniture manufacture in the tender documentColour to be approved by the Architect. 120 Kesariyaji Green MarbleProviding and laying kesariyaji green marble, 18-20 mm thick machine cut and polished to a smooth finish. Marble laid over a 1:4 cement mortar bed with white cement slurry, ensuring proper alignments and vein continuity. Joints to be filled with matching epoxy joint. 121 Wooden Laminate FlooringSupply and instakkation of 8mm thick wooden laminate flooring with a screatch-resistant, anti slip surface and click-lock joint system. Incudes foam/felt underlayment for sounfproofing and moisture resistance, skirting, trims and post-installation cleaning.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Daman And Diu View Result →
30.
Housing Urban and Rular Development #10813592 Price Bid
Tender for Construction Of Libary Building At Lalapet Head Of Lalapet Panchayat , Earthwork Excavation For Foundation (For Narrow Excavation) To Full Depth As Per Designed In All Soils And Sub Soils Except Soft Disintegrated Rock Not Requiring Blasting And Hard Rock Requiring Blasting And Bailing Water Wherever Necessary. Refilling The Sides Of Foundation With Excavated Earth Other Than Sand In Layers Of Well Rammed And Compacted And Depositing The Surplus Earth In Places Shown By The Departmental Officers With An Initial Lead Of 10M And Initial Lift Of 2M And Clearing And Leveling The Site Etc. Complete Complying With Standard Specification. , Supplying And Filling In Foundations And Basement With Filling M- Sand In Layers Not Exceeding 15 Cm.Thick,Well Watered,Rammed And Consolidated Etc. Complete Complying With Standard Specifications. , Plain Cement Concrete 1 : 4 :8 ( One Part Of Cement, Four Parts Of Sand And Eight Parts Of Hard Broken Stone ) Using 40 Mm Gauge Hand Broken Hard Broken Granite Stone Jelly Complying With Standard Specifications In , Refilling The Approved Good Quality Earth In Plinths, Area Development Etc. Wherever Specified In Layers Is Not Exceeding 200 Mm Thick, With Available Earth At Site. , Supplying And Filling Of Good Earth Filling Locally Available Earth Transported From The Outside Including Consolidation, Leveling Specified In Layers Of Not Exceeding 200 Mm Thick., Etc. Complete. , Supplying And Erecting Centering And Shuttering For Soffits Including Necessary Supports And Strutting Up To 3 M Height For Plane Surfaces As Detailed Below In All Floors With All Cross Bracings Using Mild Steel Sheets Of Size 90 X 60 Cm And 10 Bg Stiffened With Welded Mild Steel Angle Of Size 25Mm X 25Mm X 3 Mm For Boarding Laid Over Silver Oak Joists Of Size 10Cm X 6.50 Cm Spaced At About 90 Cm Centre To Centre And Supported By Casurina Props Of 10Cm To 13 Cm Dia Spaced At Not More Than 75 Cm Centre To Centre Etc. Complete Complying With The Standard Specification.(Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Centering And Shuttering For Soffits Including Necessary Supports And Strutting Up To 3 M Height For Plane Surfaces As Detailed Below In All Floors With All Cross Bracings Using Mild Steel Sheets Of Size 90 X 60 Cm And 10 Bg Stiffened With Welded Mild Steel Angle Of Size 25Mm X 25Mm X 3 Mm For Boarding Laid Over Silver Oak Joists Of Size 10Cm X 6.50 Cm Spaced At About 90 Cm Centre To Centre And Supported By Casurina Props Of 10Cm To 13 Cm Dia Spaced At Not More Than 75 Cm Centre To Centre Etc. Complete Complying With The Standard Specification.(Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Centering And Shuttering For Soffits Including Necessary Supports And Strutting Up To 3 M Height For Plane Surfaces As Detailed Below In All Floors With All Cross Bracings Using Mild Steel Sheets Of Size 90 X 60 Cm And 10 Bg Stiffened With Welded Mild Steel Angle Of Size 25Mm X 25Mm X 3 Mm For Boarding Laid Over Silver Oak Joists Of Size 10Cm X 6.50 Cm Spaced At About 90 Cm Centre To Centre And Supported By Casurina Props Of 10Cm To 13 Cm Dia Spaced At Not More Than 75 Cm Centre To Centre Etc. Complete Complying With The Standard Specification.(Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Centering And Shuttering For Soffits Including Necessary Supports And Strutting Up To 3 M Height For Plane Surfaces As Detailed Below In All Floors With All Cross Bracings Using Mild Steel Sheets Of Size 90 X 60 Cm And 10 Bg Stiffened With Welded Mild Steel Angle Of Size 25Mm X 25Mm X 3 Mm For Boarding Laid Over Silver Oak Joists Of Size 10Cm X 6.50 Cm Spaced At About 90 Cm Centre To Centre And Supported By Casurina Props Of 10Cm To 13 Cm Dia Spaced At Not More Than 75 Cm Centre To Centre Etc. Complete Complying With The Standard Specification.(Payment For Centering Shall Be Given After The Concrete Is Laid). , Providing And Laying In Position, M-20 Grade In Accordance With Is:456-2000, Using 20Mm And Down Grade Hard Broken Granite Stone Jelly For All Reinforced Cement Concrete Items Of Works With Minimum Cement Content Of 350Kg/M3 And Maximum Water Cement Ratio Of 0.50, Including Admixture (Plasticiser / Super Plasticiser) In Recommended Proportions As Per Is:9130 To Accelerate, Rated Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About (5.0 Cu.M) 7730Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3Cum) 5156 Kg. Of 10-12Mm Machine Crused Stone Jelly And With About (4.79Cum) 7670 Kg Of Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc.,And Providing Fixtures Like Fan Clamps In The Reinforced Cement Concrete Floor / Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And Fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , Providing And Laying In Position, M-20 Grade In Accordance With Is:456-2000, Using 20Mm And Down Grade Hard Broken Granite Stone Jelly For All Reinforced Cement Concrete Items Of Works With Minimum Cement Content Of 350Kg/M3 And Maximum Water Cement Ratio Of 0.50, Including Admixture (Plasticiser / Super Plasticiser) In Recommended Proportions As Per Is:9130 To Accelerate, Rated Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About (5.0 Cu.M) 7730Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3Cum) 5156 Kg. Of 10-12Mm Machine Crused Stone Jelly And With About (4.79Cum) 7670 Kg Of Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc.,And Providing Fixtures Like Fan Clamps In The Reinforced Cement Concrete Floor / Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And Fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , Steel - Fe 500 D: Supply, Fabrication And Placing Of Reinforcement Steel Of High Yield Strength Ribbed Bars Of Various Diameters And Grade Conforming To Is 1786 For Reinforced Concrete Work. The Work Includes Recoiling, Straightening, Cutting, Bending, Fabricating, And Placing In Position, At All Levels Including Lead And Lift, According To Drawings, Specifications Etc. Complete And Supply & Use Of 18G Black Annealed Binding Wire Double Fold To Tie The Bars In Position And Providing Precast Cement/ Pvc Cover Blocks For Main Reinforcement To Ensure Specified Cover And Complete., Including All Labor Charges Etc As Directed By Departmental Officers. , Brick Work In Following Cement Mortar 1:5 Using Best Quality Ii Class Table Moulded Bricks 83/4 X 41/4 X23/4 For Foundation And Basement Including Curing Etc.,Complete Complying With Standard Specification.Including Scaffolding Curing Cost Of Reinforcement Etc.All Complete As Per Specifications And Drawings As Directed By The Engineer In-Charge. , Brick Work In Following Cement Mortar 1:5 Using Best Quality Ii Class Table Moulded Bricks 83/4 X 41/4 X23/4 For Foundation And Basement Including Curing Etc.,Complete Complying With Standard Specification.Including Scaffolding Curing Cost Of Reinforcement Etc.All Complete As Per Specifications And Drawings As Directed By The Engineer In-Charge. , Brick Partition Walls Of 11.50Cm Thickness Using Best Quality Ii Class Table Moulded Bricks 83/4 X 41/4 X23/4 In Cement Mortar 1:3 (One Cement And Three Sand) Using Hoop Iron Reinforcement If Found Necessary Including Curing Etc. Complete And As Directed By The Departmental Officers. , Supplying And Painting The Walls With Two Coats Of Wall Putty As Instructed By The Departmental Officers Including Preparation Of Surface Curing, Etc., Complete In All Floors Complying With Standard Specifications (The Wall Putty Shall Be Got Approved By The Executive Engineer Before Use Of Work). , Providing & Applying 12 Mm Thick Cement Plaster In Cm 1:5 (1 Part Of Cement: 5 Parts Of Sand) To Walls Internally In Single Coat At All Levels To Correct Line And Level Including Chicken Wire Mesh At All Joints Of Brick And Concrete Surfaces With Minimum Overlap Of 150 Mm In All Directions, Scaffolding, Rounding Off Or Chambering Of Corners, Offsets, Fin/ Bands, Projections, Etc. And Cleaning Of Surface, Raking Out Joints, Roughening Of Surface, Chiseling The Undulated Surface Wherever Necessary And Curing, Etc., All Materials And Labor Complete In All Respects Including All Lead, Lift And Descent And As Directed. , Providing & Applying 12 Mm Thick Cement Plaster In Cm 1:5 (1 Part Of Cement: 5 Parts Of Sand) To Walls Externally In Single Coat At All Levels To Correct Line And Level Including Scaffolding, Rounding Off Or Chambering Of Corners, Offsets, Fin/ Bands, Projections, Etc. And Cleaning Of Surface, Raking Out Joints, Roughening Of Surface, Chiseling The Undulated Surface Wherever Necessary And Curing, Etc., All Materials And Labor Complete In All Respects Including All Lead, Lift And Descent And As Directed. , Paving The Floor With Best Quality Vertified Tiles Of Size 600 X 600 X 8Mm Of Approved Colour, Shade And Quality Laid In Cement Mortar 1:3 (One Cement And Three Crushed Stone M.Sand) 20Mm Thick In All Floors And The Top Pointed With The White Cement Mixed Same Colour Pigments Etc., Complete Complying With Standard Specification. (The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works) , Providing Granolithic Floor Finish Of The Following Thickness With Plain Cement Concrete 1:2:4 (One Cement, Two Sand And Four Aggregate) Using 10 To 12Mm Gauge Hard Broken Stone Jelly Including Laying, Finishing And The Top Rubbed Smooth With Power Trawl,(25 Mm Thick) , Providing, Fabricating And Fixing M.S. Grills Windows, And Ventilator, Gates, Ladders, Rail Pipes, Nosing Angles, With M.S.Lugs In Staircase Steps Etc., Made Out Of M.S Rods, Flats, Angles, Pipes, Channels Etc. Including Necessary Fixtures Complete As Per Drawings And Specifications And As Directed By The Engineer , Upvc Window.The Cost Includes Cost Of All Materials, Labour Charges And Other Incidental Charges, Etc., Complete , Manufacturing, Supplying And Fixing Of Steel Doors With Following Specification.Ms Angle Of Size 40X40x6mm At 3.5 Kg/M Used For Outer Frame And Ms Angle Of Size 35X35x5mm At 2.6 Kg/M For The Shutter Frame. Stiffeners With 32X6mm At 1.5 Kg/M Ms Flat Is Provided As The Lock Rail Of The Door And Welded Intact On Both Ends To The Shutter Frame.18 G Cr Sheets Of Best Quality Is Laid As Panel In The Shutter Frames. 18X5mm At 0.70 Kg/M Ms Flat Is Welded Over The 32X6mm At 1.50Kg/M Ms Flat On The Rear Side Of The Door, Sandwiching The Cr Sheet For Rigidity. Additional Stiffeners With 18X5mm At 0.7 Kg/M Ms Flats Are Provided Diagonally On The Rear Side Of The Shutter. 300Mm Length Of Hinges 2Nos, For Shutter Is Provided. 6 Nos. Of 250Mm Length Hold Fasts 200Mm Length Specified At The Ends Are Welded To The Outer Frame Of The Door. Tower Bolt 2 Nos. At The Top Provided. , Supplying And Painting New Ceiling Plastered Surface With Two Coats Of Distempering One Coat Of Distemper Primer , Supplying And Painting New Plastered Internal Wall Surface With Two Coats Of Distempering One Coat Of Distemper Primer , Supplying And Painting The Walls With One Coat Of Wall Primer And Two Coats Of Exterior Emulsion (Apex Or Equivalent) As Instructed By The Departmental Officers Including Preparation Of Surface Curing, Etc., Complete In All Floors Complying With Standard Specifications (The Colour And Shade Of The Cement Paint Shall Be Got Approved By The Executive Engineer Before Use Of Work). , Paving The Top Of Roof With Solar Reflective Ceramic Tiles Of Size 305 X 305 X 7Mm Thick Of Approved Quality And Colour Laid In Cement Mortar 1:3 (One Cement And Three M.Sand) 12Mm Thick And Pointed With Tile Grout (Nitotile Grout Or Equivalent) And Cement In The Ratio Of 1:3 For Joint, Curing Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Make And Brand Of The Tiles Should Be Got Approved By The Executive Engineer Before Use On Works) , Supplying And Fixing Cuddapah Slab For Cupboard Shelf , Providing Cup-Board Shutter With Frame Using Termite / Water Proof Plywood Of 19Mm Thick Over Which Laminated Sheet Of 0.8Mm Thick Fixed Inside The Shutter And 1Mm Thick Fixed In The Outside Of The Shutter Using Fevicol Along With Necessary Furniture Fittings, Such As, Hydralic Hinges, Tower Bolt, Handles, Multi Purpose Locks Etc., As Directed By The Departmental Officers. The Design Pattern, Water Proof Plywood, Laminate Sheet And Other Materials Should Be Got Approved From The Executive Engineer Befoe Use On Wor , Cement Concrete 1:2:4 Using 20 Mm And 12 Mm Metal Including All Cost And Conveyance And All Labour Charges , Provision For Electrification , Wiring 2 X 1.5 Sq.Mm (22/0.30)Pvc Insulated Unsheathed Sc.Cu.Conductor Of 1100 V Grade In Suitable Pvc Rigid Pipe On Wall And Ceiling With Pvc Accessories With Tw Switch Box With In Flush With Wall Covered With Hylem Sheet Of 3 Mm Thick With Painting Of Suitable Colour For Concealed Pvc Light/ Fan Point (Sd No.25) , Supply And Fixing Of 4-40W Led Tube With Fitting Inclusive Of All Charges (Sd 88) , Wiring 2 X 1.5 Sq.Mm (22/0.30)Pvc Insulated Unsheathed Sc.Cu. Conductor Of 1100 V Grade In Suitable Pvc Rigid Pipe On Wall And Ceiling With Pvc Accessories With Tw Switch Box With In Flush With Wall Covered With Hylem Sheet Of 3 Mm Thick With Painting Of Suitable Colour For Concealed Pvc Plug Point (Sd No.38) 5 Pin Plug Point , Supply And Fixing Of 1200Mm Sweep Ac Ceiling Fan Complete With Stepped Electronic Regulator With 300Mm Down Rod On The Existing Clamp Sd 106 , Supply And Fixing Of Water Tight Bulk Head Fitting With Guard (Philips / Bajaj / Crompton / Klite) Suitable For Incandencent Lamp And 60W Bulb (Sd N0.83) , Supply And Run Of 2 Of 1.50 Sq.Mm Polythene Insulated Pvc Sheathed Heavy Duty Sc Copper Conductor Of 1100 V Grade On 7/20 Gi Bearer Wire For Service Connection Mains (Sd No.64) , Supply And Fixing Of Tneb Meter Board Suitable For 32A Single Phase Service Connection With 32A Fuse Unit (500V) 32A Neutral Link And Earth Link (1 X 1/8 Copper Flat) On Tw Plank Of Size 375Mm X 300Mm X 19Mm With Supporting Tw Reepers Of 1 Thick An Either Side With Painting With Suitable Bolt And Nuts For Fixing The Tw Plank On Wall With Earth Connection And Inter Connection With 7/20 Pvc Insulated Copper Wire From Eb Meter To Fuse Unit. (Sd No. 125) , Supply And Run Of 2X4 Sqmm (22/0.3) Pvc Insulated Sc Unsheathed Cu.Conductor Of 1100V Grade In 25Mm Dia Gi Pipe (Class B) Suitably Bent At Both Ends With Necessary Angle Iron Upright And End Supports For Mains Sd 70 , Supply And Fixing Of 16 Amps Dp Switch Of 500V With Metal Clad With Fuse And Neutral Sd 142 , Gst Amount For Providing Service To Government Contract Works For The Above Construction & Maintenance Works.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
31.
Defence #10793129 Price Bid
Tender For Additional / Alternator Certain Offer Md Accommodation Under Age B/R I At Chandimandir; 1 Taking down chowkats or frame not exc. 1.5 Sqm with shutters, without taking off shutters from the frame,complete all as specified and directed. 2 Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame,complete all as specified and directed. 3 Taking down shutter of any description exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed. 4 Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). 5 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in- Charge 6 35mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides all as specified & directed by Engineer-in-charge. 7 35mm thick second class hard wood glazed and Skeleton shutteropen rebated & prepared to receive glass, gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut & mitred beads for securing glass etc.; Size of members of shutters as specified in SSR Part 1, Section 8, clause8.24 (a); supplied and fitted to chowkats complete all as specified and directed. 8 150 mm size aluminium anodized, barrel tower bolt (ISI Marked) of extruded section complete all as specified and directed. 9 Aluminum alloy, anodized, sliding door bolt 2500mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed. 10 Butt hinges 100mm long, of extruded aluminium alloy with galvanised mild steel hinge pin, complete all as directed. 11 150mm size aluminium handle (ISI Marked), cast type, anodised,complete all as specified & directed by Engineer-in-charge. 12 Dismantling boarding, any type and any description, fixed any position with nails all as specified and directed. 13 18mm thick HDHMR Board of uniform density not less than 850 kg/m3, both faces of HDHMR board shall be prelaminated as per approved design, fixed as in cupboard shutters complete all as specified and directed by Engineer-in-charge. 14 PVC body magnetic shutter catcher for kitchen cup boards cabinets etc, complete all as specified and directed. 15 Continuous (piano) hinges, mild steel bright finish, width of flap when open30mm, complete all as specified and directed. 16 1.5mm thick scratch proof high gloss Acrylic sheet, to be pasted on front shutters of HDHMR board, complete all as specified and directed by Engineer-in-charge. 17 20mm wide & 1mm thick PVC edge beading of PVC pasted on edges with suitable adhesive, complete all as specified and directed. 18 Angular stop cock, fancy type, cast copper alloy chromium plated, screwed down,screwed both end for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed. 19 Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, fixed as in repair complete all as specified and directed. 20 Wall / sink mixer for mixing hot & cold water, chromium plated suitable, and screwed down for 15mm bore GI pipe or union, fixed as in repaircomplete all as specified and directed. 21 WHB mixer, for mixing hot or cold water, screwed down for pipe and fixed, suitable for 15mm bore pipe fixed as in repaircomplete all as specified and directed. 22 Harrison rails 25 mm size, mild steel, chromium plated with fixing brackets, stops, rollers etc. for curtain rod inclulding taking down defective bracket complete all as specified and as directed. 23 Towel rail 600mm long ofmild steel, chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats, fixed as in repair complete all as specified and directed. 24 Chromium plated, fancy type shower rose with swivel joints 125mm dia with arm and fixing to steel pipe 15mm bore, fixed as in repaircomplete all as specified and directed 25 Sheet glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with CP bracket guard and railing 60cm long, fixed as in repair complete all as specified and directed. 26 PVC connections 15 mm size with PTMT nuts of length 450 mm , fixed as in repair complete all as specified and directed. 27 Vitreous china, wash down water closet pan, white, Pedestal pattern WC with ‘P’ or ‘S’ trap, with all fittings and connection, fixed as in repairs complete all as specified and directed. 28 Kitchen sink with drainage board made out of stainless steel sheet 1.0mm thick with plug, washers and wastes, overall size 940 x 460 x 203mm, bowl size 405x354x203mm incl fixing of cantilever brackets to wall with making hole complete in cement mortar 1:2 and connection to union, pipe, fixed as in repair complete all as specified and directed. 29 Plastic water closet seat cover white closed pattern with flat bottom mild steel chromium plated or aluminium hinging device, fixed as in repairs, complete all as specified and directed. 30 Single piece EWC (one piece), minimum size 715 x 335 x 715mm, , snow white colour, S-trap with integraed flusing cistern, including slim soft close seat cover , fixed as in repairs, complete all as specified and directed. 31 Precast concrete interlocking paver block, with grey cement and no pigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade,laid over and including 25mm thick sand cushioning,well ramming complete all as specified and directed 32 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. 33 Demolition of brick masonry, built in cement mortar including all quoins arches, pillars etc completeall as specified & directed 34 Brick work using old size sub class B bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:4, complete all as specified and directed. 35 15mm thick rendering in Cement and Sand mortar 1:4 over brick , concrete surfacesfinished fair and even without using extra cement and providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed. 36 Applying Two or more coats on new plastered surfaces of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paintof required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. 37 Two coats of white wash on ceiling surfaces including preparation of new plastered surfaces complete all as specified and directed. 38 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premises, complete all as specified and directed. 39 Non skid ceramic coloured tiles7 to 8 mm thick, area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in CM 1:6, complete all as specified and directed. 40 Glazed coloured ceramic tiles in vertical surface 450mm x 350 x7mm thick, set and jointed in neat cement slurry over 10mm thick thick rendering in cement mortar 1:4, for receving the tiles,complete all as specified and directed. 41 Coloured vitrified ceramic tiles, light shade,10mm thick (square / rectangular) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. 42 All as per serial item 41but as in skirting/ daddo including,over & including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. 43 15-18mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and likein cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade ofgranite over and including 15mm thick screed in cement mortar 1:6 complete all as specified and directed. 44 Granite stone slabs, 16 to 18mm thick,width and length as per site requirement, best qualitymachine cut andpolished to be fixed infloors,cooking platform, tread, raiser of steps and vertical surfaces etc and jointed with gray cement slurry and pointed in white cement mixed with marble dust (1:2) with admixture of pigment to match the shade of slab, rubbing, cutting / rounding of edgesand corners where required with and including 15 mm thick screed bed in cement mortar 1:4, Complete all as specified and directed. 45 Dismantling plain or corrugated steel sheeting, AC sheetany gauge, thickness, including nainital or similar pattern roof coverings complete all as specified & directed by Engineer-in-charge. 46 Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. 47 Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified & directed by Engineer-in-Charge 48 Rolled sections as in main and cross beams, hip and jack rafters,purlins where connectedto common rafters and running rails and guidesforsliding doors, fixedwithangle cleats or other connecting plates, conforming to Fe-290 Gde E165, all as specified and directed. 49 Two coats of synthetic enameled paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. 50 PVC (SWR) pipe, 110mm bore, single socketed in any length with rubber ring joints fixed to wall/floor including taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, fixed as in repaircomplete all specified and directed. 51 110mm bore PVC (SWR) bends any radius, complete all as specified and directed 52 Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators/ partitions including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. 53 Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge 54 Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) ofapproved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. 55 4.80mm thick ordinary quality tinted glass,fixed to aluminum frame workin panels not exc 0.5 Sqm in each pane, complete all as specified & directed. 56 4.80mm thick ordinary quality tinted glass,fixed to aluminum frame workin panels exc 0.5 Sqm in each pane, complete all as specified & directed. 57 Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including fixed with stainless steel wire staplescomplete all as specified & directed. 58 Food grade stainless steel wire in any baskets of a modular kitchen (storage basket, cup and saucer basket, jas basket, thali basket, cutlery basket, grain trolley , plain basket, bottle pull out etc), minimum loading capacity65 Kg, made by min 6 mm dia stainless steel round bars, proper welded and joints finish by grinding, chromium plated finish, fixed properly with WPC board of any thickness as per design approved, including fixing of auto closing hinges, ball bearing runners of any description, stainless steel handles fixing clips, sliding frame structure, SS screw etc complete all as specified and directed by Engineer-in-charge.Note:1. Only weight of SS wire basket will be measured before fixing.2. Only Fixing of all Fitting/fixtures like handles, hinges, ball bearing runners, telescopic channels etc are included and will be paid in separate items as supply only. 59 Supply only of soft auto closing hinges openable at 0 degree for kitchen cabinet shutters Make :Hettich/Ebco/ Prime 60 Supply only Ball bearing runners 45 mm soft closing Telescopic Channel (20 Inch) full extension load capacity 50 Kgs, Black powder coated, Make :Hettich/Ebco/ Prime 61 Metal profile section for each shutter in kitchen cabinets either below or above slab complete all as specified. 62 Excavation in post holes (or similar hole) each in hard and dense soil n.exc 0.50 cu m getting out and removing surplus spoil at a distance not exc 50 metre and making good surfaces complete all as specified and directed. 63 Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, sub base and mass concrete complete all as specified & directed. 64 Plain cement concrete type B-0, 1:2:4 using (2012.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. 65 Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0,all as specified and directed. 66 Powder coated GI Frame work grid Size of grid 605 x 605mm for ceiling comprising of Gl periMetre channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and directed 67 4mm thick Nonasbestos fibre cement building boardsfixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping complete all as specified. 68 Factory made 18mm thick solid WPC (Wood Polymer Composite) board of density 650 Kg /cum of one sideprelaminated / rigidlam with any colour and other side balancing laminate as in cup board/ kitchen cabinet shutter/ drawer, front shuters, fixed with screws, solvent/ adhesive, complete all as specified and directed. 69 Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socketor power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete 70 Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. 71 All as per serial item 70 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 72 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 73 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 74 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 75 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 76 Decorative wall light 12 watt LED indoor type antique design, synthetic type material, perfect ambience for living . Bedroom suitable for all type of lamp complete all as specified and directed. 77 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed. 78 Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mmand provision of flexible copper cable 3 core from ceiling rose to exhaust fan complete all as specified and directed. 79 Cutting openings, through brick walls in round shape , for 300mm dia exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required including finishing and matching the disturbed surface and removing surplus unserviceable bricks, hard-core, etc..from site and rubbish complete all as specified & directed by Engineer-in-charge. 80 Taking down carefully Geysers of any capacity and removing with materials to store for keeping in safe custody by the contractor and deposit to the MES store yard, check its serviceability and futher action, complete all as specified & directed 81 Fixing only seviceable Geysers of any capacity and connecting up with existing site as sper direction compelte received from MES store yard complete all as specified and directed. 82 Electric water heater(vertical type geyser), capacity 25 litre, 2 KW BEE 5 Star rated AC single phase, including MS glass lined inner tank, glass coated heating element, high density PUF insulation, Anode rod protection, heavy duty fastner not less than 100mm with suitable size of nut & washer grouted in wall with complete mason work for proper mounting of geyser fastner bolts with all accessories such as safety valve, thermostat, NRV, connection piece etc. making necessary inlet / outlet water connection, testing on load including connection with 3 core PVC insulated, sheathed, stranded copper conductor cable / flexible shord with plug complete all as specified and directed. 83 Electric auto clean glass chimney (ISI Marked) with invertor technology, suction capacity 1400-1500m3/h, Filterless tech 6062 BLDC AC 9 speeds control brushless powerful DC motor, Touch controls with motion sensor, wave and start, stainless steel body black colour with LED light including flexibly adjustableto lenght PVC pipe 150mm for fixing in wall inside and outside for exhaust cooking air through chimney with louvers complete all as specified and directed. Make as approved by GE
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
32.
Defence #10790289 AOC
Tender For Special Repair To Building No T-89 At Signal Vihar Of 172 Inf Bn (Ta) Madras, Brichgunj Mil Stn, Sri Vijaya Puram; 1 Taking down chowkats or frame with shutters area n.exc 1.5 Sqm (without taking of shutter from frame) including cutting holes to facilitate the taking down etc complete all as directed. 2 All as per item no 1 above but area exc 1.5 and n.exc 4 Sqm Each 3 Dismantling floor hearth or wall tiling of any description, size and thickness including cement mortor bedding (but not backing), removing rubbish off the premises etc complete all as directed. 4 Taking down cement plaster on brick masonry walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as directed. 5 Taking up or down 20mm bore of pipe GIsteel tubing and connections, including cleaning for refixing or removal outside MD land etc complete all as directed. 6 All as per item No 5 above but 25 or 32 mm dia 7 All as per item No 5 above but 40 or 50 mm dia 8 Demolition of Precast Concrete Block work built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed. 9 Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortor etc complete all as directed. 10 Demolition of PCC unreinforced in ground floor and paving above or below any thickness etc complete all as directed. 11 Demolition of reinforced cement concrete in roofs, floors (other than ground floor), beams, staircase, landing, chajjas and other similar suspended works etc complete all as specified and directed. 12 Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed. 13 Dismantling plain or corrugated steel sheeting any gauge, thickness, in roof coverings etc complete all as specified. 14 Dismantling wrought iron or mild steel work of any description not otherwise provided for and fixed in any position etc completeall as directed. 15 M&L RCC M-30 (design mix) using 20 mm graded stone aggregateas in Chajjas complete all as specified and directed. 16 Use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges for flat fair finished surfaces complete all as specified and directed. 17 M&L TMT mild steel bars 6 to8 mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming tocomplete all as specified and directed 18 M&Lprecast RCC (1:2:4) type B1 (20 mm graded crushed stone aggregate) as in cover slabs and similar articles with plain faces set in CM (1:4) complete all as directed. 19 M&L Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) all as specified. 20 Cutting chases in brick/ block masonry walls built in cement mortor for concealed water tubing or concealed conduit wiring, etc., and making good in CM 1:3, cutting not exc 10 cm girth etc complete all as directed. 21 M&L for Granite (of any type) work 16 to 18mm thick (table rubbed and polished) in flooring, steps, jambs, pillars, window cills, cooking platforms, vertical surfaces/wall lining and like including 15mm thick bedding in CM 1:6and pointing in white cement (1:2) using marble dust with admixture of pigment to match the colour of tiles etc complete all as directed. 22 Extra over Granite or marble slabs as in rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as directed. 23 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (max toxicity index of 12 for 100gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. 24 S&F factory made wire gauge panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC ‘C’ channel having a PVC sheet strip of 5mm thick & 15mm wide stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes fitted in frame welded / sealed to the stiles & rails with suitable decorative PVC beading of 10mm x 10mm (90degree), and joined together with solvent cement. The wire gauge shall be stretched to tighten firmly 25 S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/ Chowkhat of size 50 x 125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (max toxicity index of 12 for 100gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 26 All as per item no 25 above but size of size 50x100mm 27 S&F 150 mm size aluminium anodised barrel tower bolts of extruded sections, with cast or sheet barrel and rolled or cast bolts etc complete all as directed. 28 S&F aluminium alloy, anodised, sliding door bolt with hasp, staple & fixed clips of sheet, cast or extruded section & fixed bolts & sliding bolts of extruded section or cast aluminium alloy, length of bolt 300 mm etc complete all as directed. 29 S&F 100mm size butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed etc complete all as directed. 30 S&F incontinuous piano type hinges mild steel bright finish or electro galvanised width of flap 30 mm (when opened) complete all as directed 31 S&F Aluminium (extruded section ) Door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg andfixed etc complete all as directed 32 S&F 150 mm size extruded aluminium handles fabricated type, anodised and polished etc complete all as directed. 33 S&F 100 mm size extruded aluminium handles fabricated type, anodised and polished etc complete all as directed. 34 S&F magnetic catch of approved design and pattern and fixed as directed etc complete all as directed. 35 S&F in repairs anodised aluminium alloy curtain rails 20mm dia with brackets fixed to required lengths etc complete all as directed. 36 S&F floor door stopper of aluminium alloy body and tongue anodised, with hard drawn steel spring fixed in floor overall length of cover plate 150mm etc complete all as directed. 37 S&F aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and as directed 38 S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. 39 S&F powder coated of any colour(minimum thickness of powder coating 50 micron)aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed 40 S&F powder coated of any colour (min thickness of powder coating 50 micron) aluminium window and ventilator shutters, side/top hung type without sash bars, aluminium sections weighing 0.55 kg/m with and including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (2 no.) complete all as specified and as directed. 41 S&F aluminium composite panel sheet of 3 to 4 mm thick as in cup board, wall cladding and false ceiling fixed onaluminium frame work with plastic strips (double sided sticker) of suitable size of varying thickness of 10 to 30 mm, applying adhesive over aluminium sections for fixing composite panel and fixed with screws. The joints of panels shall be filled with weather proof sealant, The board shall be stuck with a layer of any colour high intensity reflective grade polymer sticker installed using epoxy adhesive complete all as specified and as directed. 42 M&L for false ceiling with aluminum grid work (Size of grid 600x600mm) with 35x25x1.5mm main tee and 25x25x1.4mm cross tee and wall angle and suspended with 2mm dia GI wire hooked to roof with needful adjustment bolts at an interval of 1.20m centre to centre staggered and board with Eco board decorative type size 600x600x4mm thick etc complete all as directed 43 M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete incl 15mm thick screed bed in CM 1:6 all as specified and as directed. 44 All as per item no 43 above but prepolished kota stone in riser of steps, skirtings, dado and pillar with and including 10mm thick CM 1:4 backing coat 45 All as per item no 43 above but single piece prepolished stones in Treads with full round nosing and two nos 6mm wide and 3mm deep grooves along the exposed length. 46 M&L for 25 mm thick PCC (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in floor finished rough to receive tiles complete all as specified and as directed. 47 M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded aggregate as in Plinth Protection etc complete all as directed. 48 M&L for PCC in surface channels and drains type C2 1:3:6 (40 mm graded aggregate) all as specified and as directed. 49 Extra for forming fair finished drain or channel 30cm inner girth in cement concrete all as specified and as directed. 50 M&L for glazed ceramic coloured tiles on vertical surface 300x 450X 7mm thick with and including 10mm thick CM 1:3 backing coat, set and jointed in neat cement slurry and pointed in white or colour cement to match etc complete all as directed. 51 M&L forNon - skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) laid in floors area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc.with and including 15mm thick screed bed in CM 1:6 , set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as directed. 52 M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) light shade polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed. 53 All as per item No. 52 above but in vertical surfaces such as skirting and dado, laid over and including 10 mm thick rendering in CM 1:4. complete all as specified and as directed. 54 M&L for water proofing treatment to sunken surfaces of the slab in following sequences:- 55 (a) Slope correction by using 1:2:4(Nominal Mix) concrete minimum 25mm thickness at one end and a slope of 1:20 by using 12.5 mm graded stone aggregate with integral water proofing Chemical PIDI PROOF-LW mixed in proporation 200ml /50 Kgcementof DR Fixit of Pidilite Industries Ltd or STP No 1 (liquid) of STP Ltd in proporation 200ml / 50 Kg cement or equivalentas per manufacturer instructions complete. 56 (b) PCC padding with cement concrete 1:1.5: 3 type A0 (using 12.5 mm graded stone aggregate) 25mm thick with integral water proofing compound Dr Fixit manufactured by M/S Bouchemic or equivalent as per manufacturer instructions complete incl providing spout pipe of 50 mm as required. 57 (c) Vertical sides plastered in CM 1:4, 15mm thick with WPC @ 3 % by wt of cement and sunken portion to be filled(ponded) with water and tested for 7 days after required period of curing to observe leakages/seepages, if any, shall be arrested by pressure grouting and retested till leakages/seepages are completely stopped.(Note :-WPC Measured Separately) 58 (d) After ponding test the surface shall be dried and sides of sunken slab shall be treated with two coats proof coats black manufactured by M/S Dr fixit or equivalent as per manufacturer instructions all over and testing again for water tightness by ponding of water for 72 hours complete. 59 (e) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. 60 (f) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5 Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. 61 (g) M&L for 25 mm thick PCC 1:3:6 type C2 using 40mm graded aggregate as in Mass concrete in sunken treatment. 62 (h) M&L for 50 mm thick PCC 1:2:4 type B1 using 20 mm graded aggregate as in top surface after sunken treatment. The joints in CI/GI/PVC pipes, Nahani traps,WC, P/S traps shall be made leak proof. The gap around pipes in walls/beams shall be properly filled and sealed with water proof joint fillers. 63 (j) M&L for PCC 1:5:10 type E2 using 40mm graded aggregate as in Mass concrete in sunken treatment. 64 M&L for water proofing treatment with the following specifications including taking down existing roof treatment of any description and cleaning with water and scrubbing and disposing off the rubbish outside the premises, complete all as specified and as per manufacturers instructions:-(i)Rendering 10mm thick in CM 1:4 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement as leveling course (ii)Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm.(iii) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5 Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm.Note :- Water proofing compound shall be measured and paid separately. 65 M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed. 66 M&L for 15mm thick rendering in two layers of 10mm thick backing coat in CM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces finished even and smooth without using extra cement. (Note : Water proofing compound shall be measured and paid seperately) 67 M&L for 5mm thick rendering on fair faces of brick work or concrete surfaces as in Ceiling Surface, soffits of slab/chhajasin CM 1:3 finished even and smooth without using extra cement complete all as specified and as directed. 68 Supply only liquid integral water proofing chemicals complete all as specified and directed. [Make; Dr.Fixit Pidiproof LW+ of M/s Pidilite Industries or STP No. 1 (liquid) of M/s STP Ltd] (3% by wt of cement). 69 M&L for application of high build polymer cement sand mortar 1:2.5 with water cement ratio 0.35 to 0.45 mixing with Nito bond SBR @ 5 ltrs per 50 Kg cement on ceiling / chajja surfaces 10 to 20mm thick in two layers over slurry priming coat of 1 volume Nito bond SBRto 1 volume water, 3 volume fresh cement (5 sqm per litre Nito Bond SBR) etc all as per manufacturers instructions, including painting/finishing to match with the existing complete all as specified and as directed.[ Note : Nitobond SBR shall from Fosroc chemical (India) Pvt Ltd or equivalent chemicals of MC Bouchemics/Beck] 70 M&L for preparation of old plastered surfaces of ceiling and applying one coat of oil bound distemper etc complete all as specificed and as per directed. 71 M&L for preparation of old plastered surfaces of walls and applying one coat of oil bound distemper etc complete all as specificed and as per directed. 72 M&L for preparation of newly plastered surfaces of walland applying two coats of Oil Bound distemper over a coat of primer etc complete all as specified and directed. 73 M&L for preparation of newly plastered surfaces of ceilingand applying two coats of Oil Bound distemper over a coat of primer etc complete all as specified and directed. 74 M&L for preparation of newly plastered surfaces of wall and applying twocoat ofweather proofexterior acrylic emulsion paint with anti fungal property over a coat of exterior primer complete all as specified and directed. 75 M&L for preparation of old plastered surfaces of wall and applying twocoat ofweather proofexterior acrylic emulsion paint with anti fungal property etc complete all as specified and directed. 76 M&L for applying 1mm thick wall care putty on newly plastered surfaces of wall etc complete all as specified and directed. 77 M&L for writing letters/fiqures/numbers (Block. Roman, Italic or Indian) etc. n.exc. 30 cm high over and including black synthentic enamel painted surface all as specified and directed. 78 S&F 4.00 mm thick sheet glass ordinary quality n.exc 0.5 sqm etc complete all as directed. 79 S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, including cranking to shape as specified and fixed with self tapping screws etc complete all as specified and as directed. 80 S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, including cranking to shape as specified and fixed with self tapping screws etc complete all as specified and as directed. 81 S&F MS works as in wind ties for roof incl securing bolts etc complete all as specified and as directed. 82 S&F Roof Trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, Tee, Angle, Channel or Flat section) including distance pieces, cleats etc conforming to Fe-410-W grade E 250 Quality B complete all as specified and directed. 83 M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified and as directed. 84 M&L for providing & fixing in repairs stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with and including necessary stainless steel nuts & bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as directed. 85 M&L for preparation of new steel and iron surfacesexc 10 cm width/girth and applying two coats of synthethic enamel paint over a coat of red oxide, zinc chrome primer etc complete all as directed. 86 M&L for preparation of old painted steel surfaces over 10 cm in width or girth andapplying one coat of synthetic enamel paint etc complete all as specified and directed. 87 S&F 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors etc complete all as specified and as directed. 88 All as per item No. 78 above but 25 mm dia 89 All as per item No. 78 above but 40 mm dia 90 Supplying, hoisting and fixing in repairsrotational moulded polythylene water storage tanks (cylindrical vertical with closed top)hoisted and fixed in position all as specified in SSR Part-I of 1000 Litre capacity etc complete all as specified and directed. 91 S&F in repair 40mm bore gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe etc completeall as specified and directed. 92 S&F40mm bore ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe etc complete all as specified. 93 S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm etc complete all as directed. 94 S&F in repairs 15mm size fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed etc complete all as directed. 95 S&F in repairs 15mm size fancy type Bib taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed etc complete all as directed. 96 S&F in repairs 15mm size fancy type chromum plated Stop valves/angle cock, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixedetc complete all as directed. 97 S&F in repairs chromium plated two way bib cock 15mm bore etc complete all as specified and as directed. 98 S&F in repairs 15mm sizefancy type brass chromium platedwall mixer for mixing cold and hot water with necessary fittings, screwed down for iron pipe and fixed etc complete all as directed. 99 S&F in repairs glass shelf of size 600x120mm with brass chromiun plated fancy brackets and railing fixed with screws and wooden/plastic cleats etc complete all as directed. 100 S&F in repairs soap dish fixed with chromium plated brass screws and wooden/plastic cleats etc complete all as directed. 101 S&F in repairs Brass chromium plated tubular towel rail, 600mm long between flanges fixed with screws and wooden/plastic cleats etc complete all as directed. 102 S&FPVC connections 15mm size with PTMT nuts of length 450mm etc complete all as directed. 103 Taking down PVC waste ,vent,rain water pipes incl fittings in any position 104 S&F 75mm bore of pipe PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 105 All as per item no 95 above but 110mm dia 106 S&F 75mm bore of pipe PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 107 All as per item no 97 above but 110mm dia 108 S&F 75mm bore of pipe PVC (SWR) bends any radius with access door etc complete all as directed. 109 All as per item no 99 above but 110mm dia 110 S&F 110 mm bore of pipe PVC (SWR) plain bends any radius etc complete all as directed. 111 S&F in repairs 75mm bore of pipe PVC (SWR) vent cowletc complete all as directed. 112 S&F in repairs 110mm bore of pipe PVC (SWR) vent cowletc complete all as directed. 113 S&FStack clamps out of 50mm by 5 mm flat ironand 16mm dia roundiron stays, includingbolts and nuts andsecuring ends of stays towall or rooffor 75 mm dia pipecomplete all as specified and as directed 114 S&FStack clamps out of 50mm by 5 mm flat ironand 16mm dia roundiron stays, includingbolts and nuts andsecuring ends of stays towall or rooffor 100 mm dia pipecomplete all as specified and as directed 115 S&F in repairs Cast iron Nahani trap with diameter of outlet 75mmwith grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) etc complete all as directed. 116 S&Fin repairs 75mm dia outlet PVC (SWR) PVC (SWR) floor trap with grating including jointing with solvent cement 117 S&F in repairs glazed earthen ware viterous china wash basin white coloured (flat back or angle back type), size 550x400 mm with and including CI brackets, PVC waste pipe, 32 mm bore brass CP waste couplings with long screwed shanks and fly nuts etc complete all as specified and as directed. 118 S&F in repairs glazed earthen ware viterous china wash down water closet (pedestal pattern) white coloured with and including seat cover, white, closed pattern with recessed bottom, and cover and mild steel chromium plated hinging device and flushing pipe including connection to trap and to flushing pipe, anti syphonage pipe etc complete all as directed. 119 S&F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and as directed. 120 S&F in repairs, 10 ltr capacity, PVC flushing cistern, white, syphonic action type, low level, with inlet, ball valve float and handle, PVC flush pipe, brackets etc complete all as specified and as directed by Engineer-in-Charge. 121 S&F in repair looking mirror Bevelled Edge 600mmx450mm mounted on 6mm thickAC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers etc complete all as directed 122 S&F in repair chromium plated hand shower (health faucet) 1 meter, with PVC tube with wall hook, complete all as specified and as directed by Engineer-in-Charge. 123 S&Fin repairstainless steel grade 304, 0.50mm thick, glossy finish, wall mounted kitchen plate rack assembeled set of 750 x 600 x 250mm and fixed with screws complete all as specified and directed 124 Taking down carefully aluminium point wiring(light, fan, socket or power) DBs complete offering credit, making good disturbed surfaces of walls, floors, etc, all as specified and as directed. 125 M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated andunsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets,fan regulators etc., all as specified and as directed for the following:- 126 One light point controlled by one switch 127 One exhaust fan point controlled by one switch 128 One bell point controlled by one switch 129 One fan point controlled by one switch and one regulator 130 One 3 pin switch socket outlet point 5 amps on same board with other switches 131 One 3 pin switch socket outlet point 5 amps on independent board 132 One light point controlled by two 2-way switches, with cables 1.5 sqmm size 133 All as per item No 116 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed. 134 Supply and fixswitch piano flush button single pole oneway 5 amp complete all as specified and as directed. 135 Supply and fix switch piano flush button single pole two way 5 amp complete all as specified and as directed. 136 Supply and fix switch socket combination 3 & 2 pin (multi pin) 5 amp flush type complete all as specified and as directed. 137 Supply and fixsocket outlet multipurpose 3 & 2 pin5 amp flush type complete all as specified and as directed. 138 Supply and fix switch socket outlet multipurpose 3 pin 15 and 5 amp controlled by one switch, flush type complete all as specified and as directed. 139 Supply and fix ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and as directed. 140 Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge. 141 Supply and fix B-22 LED lamp of 9/10 watt all as speciifed and dircted 142 Supply and fix of bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed by Engineer-In-Charge. 143 Supply and fixbell Ding Dong 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge. 144 Supply and fix fan speed regulator, electronic suitable socket typefor single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge 145 S & F in repairs Single pole and neutral metal enclosure with 2 pin and earth plug and socket and top plug complete with 20 Amps MCB SP , 240 Volt all as specifiedand as directd 146 Taking down serviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site with new clamps, nuts, washers, safety wire of size not less than 1.00mm & bolts including cotter pin for complete all as directed. 147 Taking down serviceable exhaust 300 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades complete and refixing back at site with new clamps, nuts, washers & bolts complete all as directed. 148 Supply and fix in repairs exhaustfan suitable for on working of AC 230 V ,50 Hz380 mm sweep 1200 RPM,with steel metal body ,incl louvers depositing old fan in MES storecomplete all as specified 149 Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, double door suitable for mounting MCBs including taking down old MCB/DB complete all as specified and directed.Note-: Incoming & outgoing connections from yhe DB shall be provided with proper lugs/ thimbles etc 150 Supply and fix in repair sheet metal enclosure Loadline distribution vertical DB, MCCB as incomer 4 ways 415 volts, with 200 amps rated bus bar double door suitable for mounting MCCB 100 A TPN as incomer and MCBs as outgoing, Triple pole as incoming complete all as specified and directed including taking down old MCB DBs complete.The Rate shall be included the incomer MCCB TPN of 100 AmpsNote-: Incoming & outgoing connections from the DB shall be provided with proper lugs/ thimbles etc 151 Supply and fix in repair MCB single pole240 volts, 6 to 32 amps B series complete all as specified and as directed by Engineer-in-Charge 152 Supply and fix single pole and netural 240 Volts 32 amps complete all as specified and as directed by Engineer-in-Charge 153 Supply and fixing in repair of aluminium housing LED batten 20 Watt mounted battenfitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours includinglamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected. 154 Supply and fixingin repair of aluminium housing LED batten 10Watt mounted battenfitting 2 ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours includinglamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected. 155 S&F in repair of 25 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed. 156 M & Lin repairs for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessoriesfixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLSsingle core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of casing caping & one run of earth continuity conductor shall be measured as one running metre. 157 All as per item sr no 140.00 above but of size 4 sqmm complete all as specidied and as directed. 158 M&L for earthing in repairscomplete with galvanised steel earth plate electrode 60 x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I 159 supply & Layin repair XLPEinsulated,heavy duty 1100 volt grade electricarmoured LT UG cable with aluminium conductorof size 25 Sqmm 3.5 Core in trenches/along the wall/including making all connections, saddles, spacers including scaffolding if any required for saddling the cable in walls of building of height up to 25 meter, complete with aluminium lugs as required at site and as directed by Engr-in-Charge 160 Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and 38mm ID confirming to IS 14930 -II and ISI Marked all specified and directed. 161 Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out Soft/loose Soil 162 Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cmsoil / hard dense soil. 163 Removing excavated material Soft Soil / hard dense soil not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point. 164 Disconnecting the electric connection ,taking down theexisting Electric Energy meter of any type and size care fully , refix the same incl electric aconnection to the meter at existing / new location after repairs of building all as specified and as directed. 165 S& F in repairssteel water tubeslight grade (ISI marked) galvanised with all fittings supportingfor ceiling fans in ceilings of size 50 mm bore pipe, complete, all as specified and as directed by Engr-in-Charge.
Contract Date: Mar 27, 2026 Contract Value : 47.03 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
Andaman And Nicobar Islands View Result →
33.
Water Resources and Irrigation #10778603 Price Bid
Tender For Dvdb Works In Nct Of Delhi Sub Work:-Renovation Of Baghel Chaupal At Village Basai Darapur In Madipur Ac- 1 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 3 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter 4 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend 5 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Shoe (Plain) 6 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 7 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 8 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern 9 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 10 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia 11 Providing and fixing 100 mm sand cast Iron grating for gully trap. 12 Providing and fixing soil, waste and vent pipes 100 mm dia Sand cast iron S&S pipe as per IS: 1729 13 Providing and fixing plain bend of required degree. 100 mm dia Sand cast iron S&S as per IS - 1729 14 Providing and fixing single equal plain junction of required degree 100x100x100 mm Sand cast iron S&S as per IS - 1729 15 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 16 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore 17 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 20 mm dia nominal bore 18 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore 19 Providing and fixing uplasticised PVC connection pipe with brass unions 30 cm length 15 mm nominal bore 20 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 15 mm nominal bore 21 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent 22 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 23 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm 24 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm 25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 26 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below 27 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 28 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 29 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 30 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 31 Demolishing mud phaska in terracing and disposal of material within 50 metres lead. 32 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : of area 3 sq. metres and below 33 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. 34 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 35 Wall lining butch work upto 10m height with Dholpur stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width, including embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size 75x75 mm and by providing layer of 75 mm thick strips i/c 12 mm thick bed of cement mortar 1:3 (1 Cement : 3 coarse sand) i/c ruled pointing in cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in-charge. 36 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 37 Providing and fixing 34/36 watt LED panel of size 600x600mm suitable for grid ceiling control with white sheet complete with driver as required(Make Havells/Bajaj/Crompton 38 Supply of 2.0TR Spilt Air Conditioner complete with indoor & outdoor unit, compressor, refrigerant etc. 3 Star rated capacity : 2.0 TR (nominal Marketing capacity in Ton, as per BEE Standards) (Make Voltas, Daikin, O-General) 39 Supply of refrigerant copper pipe (suction & Discharge) for interconnection indoor and outdoor unit of Suitable Dia as per manufecruters standerd and recommandation for the above mentioned air conditioners 40 Supply of electirc cable of 3 core 4 Square mm from power Source to indoor or outdoor unit for each of the air conditioner preferable reputed make 41 Supplying, installation, testing and commissioning of compatrmentallised Cubicla panel board made up of 6 mm thick CRCA Sheet dust and vermin proof duly phosphatize and painted in clusive of suitablr strip, all bus bar complete with inter connection etc. 42 Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.(Group C). 43 Supplying, installation, testing and commisioning of 1200mm sweep AC electric ceiling fan capacitor type with double ball bearing complete with down rod, canopies, shackless, blades but without regulator suitable for operation on 230/240 volts, 50HZ single phase AC supply including wiring the down rod of standard length up to 1mtr with 2x1.5 Sq.mm PVC insulated copper conductor with fan sheet etc. as required (Make Bajaj/Havells/Usha/C.G.) (M/R) 44 Supplying, installation, testing and commisioning of 70/72 watt LED 6000K asymmetric new generation energy saving and environment long life versatile pressure die cast aluminium IP 66 roadway luminaries with high power LED light source complete etc. As required housing reflector and enclosed with toughened glass complete with all accessories. Phillips,Bajaj, Crompton,Helonix,Havells, (Model LHFAXU7DNP6J070). (M/R) Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
34.
Housing Urban and Rular Development #10778167 Price Bid
Tender For Maintenance of Road (Project-126 Model Road) Noida - Earth work in excavation by Mecanical means ( Hydraulic Excavator ) Manual means over Areas Exclooding 30cm in Depth , 1.5m in With as well as 10 Sqm on Plan including getting out and disposal of Excavated earth load upto 50 m and Lift upto 1.5m as direction by engineer in Charge . The Contractor has defect different utilities like Sever line, water supply line, electric cable , Telephone Cable , Gas Pipe line Etc. using Utility Detecting Machine Before Start of Excavation and Shall atart Excavated only After Getting Permission on E/I. 2 Providing and laying Cement concrete with 4cm gauge approved stone ballast, approved coarse sand and cement in the proportion of 1:4:8 (1 cement ; 4 Coarse sand : 8 graded Stone Ballast 40mm. Nominal size.) including supply of all materials, labour and T & P etc. required for proper completion of the work. 3 Providing and laying Cement concrete with 4cm gauge approved stone ballast, approved coarse sand and cement in the proportion of 1:3:6 (1 cement ; 4 Coarse sand : 8 graded Stone Ballast 40mm. Nominal size.) including supply of all materials, labour and T & P etc. required for proper completion of the work. 4 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 5 Fabrication & Manufacturing of Prestressed Hollow Core slab (Hollow area 25 to 30%) of different thickness nodular width 1200 mm in Controlled Factory Envionment with approved methodology confirming to IS 10297:1982 by using long line casting method having arrangement of proper steel bed. Concreting should bel done by batch mixing plant capable of producing zero slump concrete, transported through automatic shuttels off tandard make & layed on bed with the help of extruder/Slipfonner, finishing, curing and also provision off steam curing. Cutting, making necessary cutout/holes of required sizes for services in stab element after achieving required strength, yard handling & stacking all complete as per approved shop drawings & design mix as per the direction of the Engineer-in-change. (Cost of strands should be paid separately) Note: Exces/less cement over the specified cement content used as per design mix is payable/recoverablo separatcly) icluding steel & Transport charge. 150 mm thick hollow core stab Providing and laying in position cument 6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth and above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 7 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. 8 Brick work with Common Brunt clay F.P.S( Non-modular) bricks of class designation 100 in foundation and plinth in:Cement mortar 1:4 (1 cement :4 coarse sand) 9 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 10 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 11 12mm cement plaster on of mix: 1:4 (1 cement : 4 coarse sand) 12 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 13 Providing wall putty on Old Surface with Approved Quality Material of Berger/J.K/Birla or Similar make 2 Coats. 14 Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 15 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 16 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 17 Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. 18 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 19 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). 20 Providing and Fixing of Multi cell Polycarbonate Panels 12 mm Danpalthick with 3 cells 4 walls structure over MS Supporting structures / MS frame (Paid separately). Panel Width shall be600-900 mm to ensure best performance for wind uplift. The panels shall be uniform in color with an integral Multi-Cell core. In a cross section, the core shall be constructed of Microcell of max 4.5mm x4.5 mm and soft light finish DG both side. The appearance should be either rectangular/tight cell like to giveMR highest resistance to impact and hail damage. The weight of theSqm 5205;$208.00 panel only shall not be less than 1550 gram per square meter. panel should have co-extruded UV protection with U value 2.4 RCHIW/M2.K and UV transmission less than 0.1% with UV filtration test AS No. 1067-1990. Panel and system should have impact and shock resistance with D1-10j -M 50,300 J-M 50 400 J. I DEL Polycarbonate panels also shall have Yellowness Index as perASTM D 1925 and sample exposed to UV for minimum 2000Hrs. Panel should (have fire test-Bsido.5205.70/3gm Lowest rates reicud 21 Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 to 1.00 kg/sqm using mechanical means. 22 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm 23 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe 24 Demolishing cement concrete including disposal of material within 50 metre lead: Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 25 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 26 Extra for cutting reinforcement bars in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) 27 Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work. 28 Dismolishing brick work manually / by mechanical means including stacking of sericeable material and disposal of unserviceable material within 50 metre lead as per direction of engineer- in- charge. In cement mortar 29 Removing mortar form bricks and cleaning bricks including stacking within a lead of 50m (stacks of cleaned bricks shall be measured): From brick work in cement mortar 30 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. 31 Dismantling including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.Water bound macadam road 32 bituminous road 33 Dismantling Kerb Stone (Dismantling kerb stone by manual means and disposal of dismantled material with all lifts and up to a lead of 1000 metre) 34 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge 35 Disposal of building rubbish / malba / similarunserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer- in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 36 TR Concrete bench Supply of concrete bench as per approved design casted in FRP mould for uniform surface straingthness and appropriate edge precasted with M-25 concrete mix appropriate reinforcement, the other surface to be coated with sealer. 37 Providing and fixing of Signage of Size 3000x600x150mm height approx in MS finished as per attached drawing/image and placing on finished platform as attached drawing without damaging the edges complete as per instruction from consultant and Engineer-in-charge. 38 Providing and fixing of Decorative wall (IAM NOIDA) of Size 5000mm height approx in 75x100mm MS sections with letters in laser cuttring aluminium finished as per attached drawing and placing in position without damaging the edges complete as per instruction from consultant and Engineer-in-charge. 39 Providing and fixing of Colourful swing sculptures of Size 3000mm height approx in 1000x500mm MS finished as per attached drawing and placing in position without damaging the edges complete as per instruction from consultant and Engineer-in-charge. 40 Providing and fixing of MS Sphere entry of 2100mm height approx in 304 SS finished as per attached drawing and placing in position without damaging the edges complete as per instruction from consultant and Engineer-in-charge. 41 White Marble Modern Art Ht. 120 (3 nos of each set) 42 Concrete bench with planter supply of glass fiber reinforced concrete bench as per approved design, the planter should be casted in fiber reinforced plastic molds allowing tolerence +10 mm. The wall thickness should be minimum 25 mm, casted in portland cement based of J.K. Cement, Ultratech or equivalent, using appropriate reinforced with alkali resistence glass fiber rainging from 3 to 5% of N.E.G. Japan or ownes cornng. The bench should be pigmented with synthetic oxide non fading water proof, UV resistance pigment of M/s Bayferrox / Lanxess of equivalent. The outer surface need to be coated with sealer. 43 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 44 P/F of 4050 mm dia granite polished spheres with base plate of granite 45 Dustbin-MSWDBANALYSIS OF RATEDim:- 370 L x 340 w x 875 H mm.Capacity- 50 Ltr.Construction:-GI. powder coated frame with 70 x 12 mm synthetic wood planks cladding (synthetic wood is a composite material of wood & plastic which makes it termite free and weather resistance & has a good self life). 46 Providiing and fixing of 8x8 metal kiosk with canopy on windows and completely locable as approved by architect. 47 CNC Jali 4 mm powder coated MS Sheet 4874.12-18% GST 48 P/F of Saucer drain of Size 600x300x100 m (along the side) in PCC (1:1/2:3) Complete and provide proper slope of drain of rainwateron the top of drain including all lead lift etc complete for the fineshedItem of work as per direction Engineer in charge. Note: ( No Separate measurement will be considered for the excavation) : M 40 Grade. 49 Supply of Labour Complete at site on etc. in all respect as per direction of engineer in charge. 50 Supply of Tractor with Trolley Complete at site on hire basis including cost of diesel and driver etc. complete in all respect as per direction of engineer in charge. 51 Supply of J.C.B. Complete at site on hire basis including cost of diesel and driver etc. complete in all respect as per direction of engineer in charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Uttar Pradesh View Result →
35.
Defence #10774093 Price Bid
Tender For Welcome Maintenance Of Offrs Md Accn In Zone A Area Of Age B/R-I Under Ge (A) Ahmedabad-- 1 Notes : (i) The work consists of 01 job as under:- JOB (A) : MAINT GRANT 2024-2025(ii) Please refer schedule A notesbefore quoting the tender.(iii) Amount of Schedule of Credit shall be deducted off line by the department. 2 Taking up or down steel tubing and connections of any description and from any position incl cleaning for refixing or removing from site complete all as specified and directed 3 15mm bore of pipe 4 20mm bore of pipe 5 25mm bore of pipe 6 S&F forGI tubing concealed or open incl replacing of unserviceable GI fittings, medium grade ISI mark like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 15mm bore of pipe complete all as specified and directed 7 S&F for GI tubing concealed or open incl replacing of unserviceable GI fittings, medium grade ISI mark like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 20mm bore of pipe complete all as specified and directed 8 S&F for GI tubing concealed or open incl replacing of unserviceable GI fittings, medium grade ISI mark like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 25mm bore of pipe complete all as specified and directed 9 S&F in repair ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe 20mm bore (Minimum weight 210 gms) complete all as specified and directed. 10 S&F in repairs bib taps 15mm bore of cast copper alloy chromium plated fancy type, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed. 11 S&F in repair Bib tap standard of PTMT any colour high pressure screwed for iron pipe 15mm bore (Minimum weight 90 gms) complete all as specified and directed 12 S&F in repair 15 mm dia bore pillar taps cast copper alloy with capstan heads chromium plated fixed in repairs 15mm bore fancy type screwed down, high pressure with long screwed shanks and fly nuts, screwed down for iron pipe or for union. 13 S&F in repairs two way bib taps 15mm bore of cast copper alloy chromium plated fancy type, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed. 14 S&F in repair two way angle valve chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handle for pipe of 15mm/20mm bore complete all as specified and directed. 15 S&F in repair Stop valve of PTMT any colour high pressure screwed for iron pipe 15mm bore (Minimum weight 90gms) complete all as specified and directed 16 Supply and fixing in repairfor 15mm bore CP central hole basin mixer for WHB mixer complete all as specified and directed. Make:- Jaguar,Plumber,Cera 17 Supply and fixing in repair 15mm borefor CP wallmixer for mixing hot or cold water screwed downiron pipes complete all as specified and directed. Make:- Jaguar,Plumber,Cera 18 S&F in repair stop valve of PTMT any colour high pressure screwed for iron pipe 20mm bore (Minimum weight 112gms) complete all as specified and directed. 19 S&F in repair stop/angle valve cast copper alloy screwed down high pressure with crutch or butterfly handle for pipe of 15mm/20mm bore complete all as specified and directed. 20 S&F in repair waste coupling of PTMT (half or full threaded) for discharge pipe of 32mm/40mm bore (Minimum weight 45gms) complete all as specified and directed . 21 S & F in repairs 32 mm bore Brass chromium plated Waste coupling for wash basin with inlet and outlet screwed for pipe or connections includding necessary packing, union and cap and fixed complete all as specified and directed. 22 S&F in repair 10 litres PVC valveless, syphonic action type flushing cistern, with inlet ball valve, float and handleincloding brackets and PVC connections 15mm size with PTMT nuts oflength 600 mm complete all as specified and directed 23 S&F in repair Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. 24 S&F in repair Rotational moulded polyethylene Water storage tanks (cylindrical vertical with closed top) 1000 litres capacity hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed 25 M&L for cleaning of 1000 litre PVC Rotational moulded polyethylene Water storage tanks by empty the tank completely use mild detergent of tank cleaning solution, to scrub the inside of the tank, rinse the tank thoroughly to remove any residue, Use a disinfectant like bleaching powder or calcium hypochlorite to kill bacteria and other microorganisms and finaly Rinse the tank again to remove any remaining bleach complete all as specified and directed. 26 M&L for cleaning of 500 litre PVC Rotational moulded polyethylene Water storage tanks by empty the tank completely use mild detergent of tank cleaning solution, to scrub the inside of the tank, rinse the tank thoroughly to remove any residue, Use a disinfectant like bleaching powder or calcium hypochlorite to kill bacteria and other microorganisms and finaly Rinse the tank again to remove any remaining bleach complete all as specified and directed. 27 S&F in repair PVC lids for water storage tank of cap 500 Litres/1000 Litres complete all as specified and directed . 28 Repair to GI tubing concealed or open incl replacing of unserviceable GI fittings, medium grade ISI mark like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 15mm bore of pipe complete all as specified and directed 29 Repair to GI tubing concealed or open incl replacing of unserviceable GI fittings, medium grade ISI mark like elbow, socket, nipple, union socket, tee etc with the existing size complete including making necessary threading work to be carried out upto any height or on walls for 20mm bore of pipe complete all as specified and directed 30 S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes ; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting unions to pipe, overall size 495mmX420mm bowl size 410mmX330mmX160mm. 31 S&F in repair 300 mm ordinary mild steel rat tail rod pattern spring incl roller and roller plate complete all as specified and directed 32 S&F in repair Double/Singleaction spring hinges brass, with phosphor bronze wire spring, bright polished 100mm, complete all as specified and directed 33 S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples all as specified and directed 34 S&F Floor door stopper 150mm of amuminium alloy body and tongue, nodised, with dard drawn steel spring all as directed fixed in repairs complete all as specified and directed 35 S&F in repair Floor door stopper 150mm of amuminium alloy body and tongue, nodised, with dard drawn steel spring all as directed fixed in repairs complete all as specified and directed 36 S&F in repairs 4mm thick frosted glass panes and glazing with oil putty & pins/spring pins complete in squares n.exc 0.50 sqm each panes complete all as specified and directed 37 S&F in repair MS handles for steel windows (left or right) 150mm size complete all as specified and directed 38 S&F in repairs 18/19 mm thick12057Block boards, grade 1 quality, exterior grade, commercial type, fixed with screws to timber frame-workcomplete all as specified and directed 39 S&F 0.9 mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturers instructions complete all as specified and directed. 40 S & F magnet catcher 50 mm size for kitchen cup board shutter complete all as specified and as directed. 41 S&F 30mm width open flap Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as spacified and directed 42 S & F in repairs 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and as directed. 43 S&F in repair vitreous china squatting pan, Orissa pattern, size 580 x 440 mm white with integral foot rests and connection with cast iron P trap and to flushing pipe, anti syphonage pipe etc (excluding flushing cistern and flush pipe)complete with provision of lime concrete bedding including taking down/ Dismantling existing unserviceable WC of any description and in any position & fixingnew WC in repair and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed. 44 S & F in repair vitreous china wash basin, white flat back , size 550mmx450mm with and including Waste fittings, brass, chromium plated forbasins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated fancy typepillar tap 15mm bore,screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed. 45 S&F in repair vitreous china Wash down water closet (pedestal pattern), complete including Pedestal pan and trap and seat cover, including connection to drain ( or outgoing pipe) and flushing pipe, antisyphonage pipes etc (excluding flushing cistern and flush pipe)complete 46 Supply and Fixing in repair for European type EWC (Cascade type) with integrated flushing cistern, EWC seat cover and with necessary fittings complete all as specified and directed. Make :- Jaquar/Marc . 47 S & F in repair Glass corner self fancy type 250x250 and 10mm thick fixed its brass bracket and screwed complete all as specified and directed. Make : Jaguar Cat No 7771 or equivalent of Marc/ESS 48 S & F in repair PVC coloured bath cabinet overall size 560 x 410mm decorative design with looking mirror including all fittings complete all as specified and directed. Make :- Prayag or Equivalent 49 S&F in repair PVC seat cover for pedestal pan, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminiumisedhanging device complete all as directed. 50 Cutting chases of brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends for concealed water tubing etc and making good, cutting exceeding 10cm but not exc 20 cm girth complete all as specified and directed 51 S&F for 19/20 mm harrison rail/curtain rails stainless steel chromium plated with fixing brackets stops fixed in repairs complete all as specified and directed 52 S&F 600mmX450mm size bevelled edge mirror of selected quality glass 5mm to 5.5mm thick mounted on 6mm AC building board or commercial ply wood and plastic framing fixed to plugs with CP brass screws and cup washers fixed in repairscomplete all as specified and directed. 53 Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed 54 M&L Granite slab work 18-20mm thick in floors steps,riser,wall cladding, cooking platforms and likeincluding pointing in white cement with admixture of pigment to match with granite shade over & including screed bed 15mm thick in CM 1:6 including cutting recess opening for the sink portion and embedding complete all as specified and directed . (Note : No deduction shall be made for opening of sink portion, shall deemed to be included in the quoted rate) 55 Taking down chowkats or frame with shutters (without taking off shutters from the frame) n exc 1.5 sqm each complete all as specified and directed 56 Taking down chowkats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm and n exc 4.0 Sqm each complete all as specified and directed 57 Taking down shutters of any descriptionexc 1 Sqm but n exc 2.0mcomplete all as specified adnd directed. 58 S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides incl decorativelaminated sheet on both faces complete all as specified and directed 59 S&F factory made35 mm thick2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash members, any numbers and mited beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.20(a) supplied and fitted to chowkats complete all as specified and directed 60 S & F stainless steel wire cloth 0.36 nominal dia wire & average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as specified and directed 61 M&L for Preparation of new or previously untreated wooden surfaces of any description, not otherwise, described, over 10cm width or girth and applying two coats of synthetic enamal paint over a coat of pink primer complete all as specified. 62 M & L for preparation of old painted wooden : surfaces of any description postion and location not otherwise described over 10cms width or girth and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and directed 63 M & L for preparation of old painted steel : surfaces of any description postion and location not otherwise described over 10cms width or girth and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and directed 64 S&F solid PVC door frame of size 50mmX47mm made out of 5mm both side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening all as per specifications and drawing shown on sl page No 150 of SSR part II (for item-884) complete all as specified and directed 65 S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & both side prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; panelling of both side prelam PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent cement, supply & fixing in the frame at site as per SSR specifications & diagram/product drawing shown on sl page NO 146 of SSR Part II with the size of door shutter as required & directed 66 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed . (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 67 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x125 mm comprisingof virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed . (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 68 S&F for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) 69 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed . (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 70 Providing and fixing factory made uPVG white colour Sliding window of area n exc. 2 Sqm, Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) 71 S&F aluminium powder coated framed windows, any pattern, fixed/side hung/sliding 3 track , AC opening using powder coated aluminium sections of approved make, with or without sash bars, suitable for 5 mm thick glazing and Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm wire guaze, including necessary rubber packing, joining cleats, glazing clips, aluminium snap beading, handles, locking arrangementsetc, frame of window should be of 1.5 mm thick section & shutter secincluding cutting down existing glazed/gauge shutter completeall as specified and as directedNote :Rates include all glazing/aluminium wire cloth, rubber packing, jointing cleats, glazing clips, aluminium snap beading, locking arrangements, handleetc 72 S & Faluminium anodisedventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members andhalf portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass including necessary channel frame work, including rubber gasket and frame with wire mesh of aluminium,and deco grill ,aluminiumbeading complete all as specified and as directed. 73 S&F for butt hinges 100mm size medium weight stainless steel . 74 M&L for 150mm long extructed aluminium handle fabricated type complete all as specified and directed. 75 S&F Aluminium anodised barrel tower bolt of extruded section 200 mm sizecomplete all as specified and directed. 76 S&F aluminium alloy anodised sliding door bolt with hasp and stapple (bolt type) and fixing clips of sheet cast or extruded section with fixing bolts and sliding bolt of extruded section 300mm length & dia not less than 12mm with & including 6 Nos of bolts complete all as specified and directed. 77 Dismantling wall and ceiling boards any thickness including cover fillets complete all as specified and directed. 78 S&F Tee grid suspension system of size 600 mm x 600 mm type-1 made out of roll framed hot dipped galvanised steel zince coated of not less than 120 gm/Sqm, main runner 0.3 mm thick of section24 mm x 33 mm crross runner 0.30 mm thick of section 24 mm x 25 mm, wall angle shall be 0.63 mm thick of section 24 mm x 24 mm grid shall be suspended by 4 mm dia adjustable quick fit hanger rod, system exposed portion shall be pre painted polyester coated in off whitee/white in colour complete with material, fixing, jointing etc., with Coloured textured designer ceiling board (Everest)/Asbestos Cement white fiber Board 4mm thick of size 595 x 595 mm fixing with screws/clips complete all as per manufacturers instructions and direction. 79 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. 80 M & L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincl and over screed bed or beeding layers of mortar 15mm thick in CM 1:6 in floors, complete all as specified and directed.complete all as specified and directed. 81 M&L for Glazed ceramic tiles coloured (300x450mm) x 7mm thick, on wall dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick backing coat of tiles in CM (1:4) complete all as specified 82 M & L for coloured double chargedVirified Ceramic tiles light/Dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover and including screed bed or bedding layer 15mm thick in cement mortar 1:4 including roughening of old surface complete all as specified and directed. 83 M & L for coloured double chargedVirified Ceramic tiles light/Dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, as in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover and including 10mm thick backing coat of CM 1:6 including roughening of old surface complete all as specified and directed. 84 M & L for colouredvitrified ceramic tile, light shadeflooring of sizeof tile 600x600x8-10mmthick as in floor, set and jointed in neat cement slurry and pointed in coloured cement to match the suraface over and including screed bed or bedding layer 15mm thick in cement mortar 1:4 including roughening of old surface complete all as specified and directed. 85 M & L for colouredvitrified ceramic tile, light shadeof size 600x600x8-10mmthick as in skriting set and jointed in neat cement slurry and pointed in coloured cement to match the suraface over and including 10 mm thick rendering in CM 1:4 complete all as specified and direceted. 86 Taking down cement or lime plaster of any description from stone or brick walls etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish complete all as specified or directed. 87 M&L for rendering on external wall fair faces of brick work in two layers i.e., 10 mm thick in CM 1:6 and top layer of 5 mm thick in CM 1:4 mixed with water proofing compound in top layer @3% by the weight of cement or as per manufacturers instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. 88 M&L for 10 mm thick rendering on internal wall surfaces other than fair faces of brick/concrete surfacesin CM (1:6) and finished even and smooth without using extra cement complete all as specified and directed 89 M & L for 5mm thick rendering on cement concrete as in ceiling with cement mortaar 1:3 complete all as specified and directed. 90 Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed 91 M&L for preparation of the newly plastered surfacesof walls & applying two coatsOil bound distemper, white or tintedover a coat of primer surfaces of wall complete all as specified and directed. 92 M&L for preparation of new plastered surfaces on wallsand applying two coats of cement based paint over one coat ofPrimer on walls complete all as specified and directed. 93 M&L for preparationof new surfaces of ceiling plastered sheet andapplying three coat of white wash complete all as specified and directed 94 M&L for perparation of old decorated surface of ceiling by brooming down or steel wire brushing, scraping down smoke, soot moulds, moass and effloroscent salts trading oil and greasy spots and applyingone coat of white wash on ceilings. 95 M&L for perparation of old decorated surface of ceiling by brooming down or steel wire brushing, scraping down smoke, soot moulds, moass and effloroscent salts trading oil and greasy spots and applyingTwo coats of white wash on ceilings complete all as specified and directed. 96 M&L for perparation of old decorated surface of walls (plastered/unplastered) including cornices, pilasters etc by brooming down or steel wire brushing, scraping down smoke, soot moulds, moass and effloroscent salts trading oil and greasy spots and applyingone coat of Oil bound distemper on wall complete all as specified and directed. 97 M&L for perparation of old decorated surface of walls (plastered/unplastered) including cornices, pilasters etc by brooming down or steel wire brushing, scraping down smoke, soot moulds, moass and effloroscent salts trading oil and greasy spots and applyingTwo coats of Oil bound distemper on wall complete all as specified and directed. 98 M&L for perparation of old decorated surface of walls (plastered/unplastered) including cornices, pilasters etc by brooming down or steel wire brushing, scraping down smoke, soot moulds, moass and effloroscent salts trading oil and greasy spots and applyingone coat of cement base paint on walls complete all as specified and directed. 99 M&L for complete removal of existing treatment on wall by brooming down or scraping down smoke ,soot moulds,moass and efflorcocent salts trading oil and greasy sposts to surfaces of wall and Finishing walls with Acrylic Smooth exterior paint of required shade, Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed. 100 M&L for complete removal of existing treatment on wall by brooming down or scraping down smoke ,root moulds,moass and efflorcocent salts trading oil and greasy sposts to surfaces of wall and applying two coats of cement base paint over a coat of alkali resistace primer complete all as specified and directed. 101 M&L for complete removal of existing treatment and applying two coats of Oil Bound Distemper over 1mm thickavg plaster of paris wall care putty and alkali resistant priming paint on wall.complete all as specified and directed. 102 Demolition ofBrick work or stone/boulder masonry, build in cementmortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 103 M&L for brick work with sub class B bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed 104 M&L Brickworkwith old size sub class B bricks, straight or curved on plan to any radius in half brick thick walls, built in In CM (1:4) complete all as specified and directed 105 Repair of steel window shutter not exc 1 Sqmeach by replacing projected type unserviceable hinges with welding new hinges or welded of existing broken hinges and handles to window frames easing of shutter top proper closing with oiling to hinges and painting at welded portion to match the existing surface complete all as specified and directed 106 Hacking out old broken glass (any thickness, size, quality or description) from wooden or metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and directed. 107 S&F 3mm thick sheet glass ordinary quality and glazing with oil putty& pins/spring pins complete in squares n.exc 0.50 sqm each pane complete all as specified and directed 108 S&F 3mm thick frosted glass panes and glazing with oil putty & pins/spring pins complete in squares n.exc 0.50 sqm each panes complete all as specified and directed 109 S & F of mild steel work such as window guard bars door frame and similar work conforming to Fe – 290 Grade – E 165 complete all as specified and directed. 110 S&F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel heeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete complete all as specified conforming to Fe – 410 W Grade – E 250complete all as specified and directed. 111 S&F Rolled sections as in Purlin ,rafter ,main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plate conforming to Fe – 410 W Grade – E 250complete all as specified and directed. 112 M&Lfor preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified. 113 S&F in repairs shower rose 150 mm dia/square of brass chromium plated fancy type with or without swivel joint suitable for fixing to 15mm bore GI pipecomplete all as specified and directed. 114 S&F stainless steel kitchen plate rack, 1 mm thick of size 900 mm x 780 mm x 222 mm fixed to wall in repairs with brass screws complete all as specified and directed. 115 S&F in repair health faucet with one meter tube and hook complete all as specified and directed 116 S & F in repair 15mm size PVC connections with PTMT nuts of length 450mm and fixed in repairscomplete all as specified and directed. 117 S/Fgrating doom 150 mm size of PTMT (Minimum weight 100 gms)complete all as specified and directed. 118 Taking down CI/PVC/AC soil pipe with fittings from wall, treches of any description including fittings complete all as specified and directed 119 S & F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors incl fittings and fixtures like bend , elbow,tee etc.complete all as specified and directed. 120 S & F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls incl incl fittings and fixtures like bend , elbow,Y(equal or unequal),tee etc.complete all as specified and directed. 121 S&F in repairs 75mm bore for PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing with solvent cement..complete all as specified and directed. 122 S & F fixed in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. 123 Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed 124 S&Fmild steel tubular / rectangluar section as in coloumn, posts, raffetrs beams gasset plate andstruts embedding in concrete , and screwing etc complete all as specified and directed. 125 Taking down shutter resecuring, easing and cuttingrefixing in the same openingshutters of any description exc 1 Sqm and not exc 2 Sqmcomplete all as specified and directed. 126 S&F in repair 18/19 mm thick block board, interior grade, veneeredone both sides with decorativechoice lamination & other side balancing white lamination, fixed with screws/nails to timber frame work as in cupbord door/shelves complete all as specified and directed 127 S & F MS Auto hinges of crank 0 degree & 90 degree, fixed with screws to timber frame complete all as specified and as directed. 128 Dismatling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings incl ridge etc.complete all as specified and directed. 129 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. 130 S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. 131 Complete removal of existing water proofing treatment with washing and brushing and removal of all bushes and algaes and after drying surfaceproviding & applying first coat of acrylic polymer based elastomeric water proofingchemical coating and after drying of 1st coat applying fiber mesh and again applying 2nd coat of acrylic polymer based elastomeric water proofing coating application ofboth coat of chemical shouldt be less than 1 kg/Sqm complete all as specified and directed as Engr-in-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
36.
Science and Technology #10758410 Price Bid
Tender For Renovation Of Bill Section, General Section, R A Section, Establishment Section, Vigilance Apar Section And Record Room Of A/C Section (Civil Work); 1 Demolishing cement concrete 1:3:6 or richer mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 2 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below 3 Dismantling tile work of thickness 10 mm to 25 mm in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 4 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 5 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 6 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 7 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 8 For 15 mm to 40 mm nominal bore 9 Above 40 mm nominal bore 10 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 11 Providing and laying in position cement concrete of grade 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level : 12 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand) 13 12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) 14 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. For Granite stone slab colour black, Cherry/Ruby red and slab area over 0.50 sqm. 15 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.For Double charge vitrified tile polished finish of size 600 x 600 mm. 16 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 17 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 18 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 19 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 20 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :For New work (two or more coats) over and including water thinnable priming coat with cement primer 21 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work 22 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work 23 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 24 For fixed portion 25 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 26 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Powder coated aluminium (minimum thickness of powder coating 50 micron) 27 For fixed portion 28 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 29 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 30 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :For 150x10 mm 31 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 32 125 mm 33 100 mm 34 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. For Twin rubber stopper 35 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 36 Providing and fixing 12 mm thick prelaminated particle board with decorative lamination on both sides flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. 37 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 38 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). 39 Supplying unskilled Mandays 40 Providing and fixing 19 mm water proofing board with 0.80 mm laminated Sunmica top area and both side area with one drawer, three cup board including inside shelves, lock and key and one key board tray , binding, cable manager, cather etc with all complete fittings. (Height and width of work station is 0.75 metre and measurement will be taken as length and height of work station) as per the direction of Engineer-in-charge. (Only weight of grill to be measured for payment). For work station 41 Providing and fixing 19 mm water proofing board with 0.80 mm laminated Sunmica front area and both side area with cup board / storage cabinet including inside shelves witj all complete fittings such as cather, handle, lock & key etc. complete as per the direction and approved of Engineer-in-Charge. (Measurement will be taken as length and height of storage cabinet.) For cup board
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
Uttarakhand View Result →
37.
Defence #10733980 AOC
Tender For Special Repair To Bldg No P-139 At Fazilka Mil Station.; 1 Taking down chowkatsor frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified and directed by Engineer - in-Charge. 2 Taking down chowkatswith shutters(without taking off shutters from the frameexceeding 1.50 sqm each but not exceeding 4 sqm) removing to store all as specified and directed by Engineer - in-Charge. 3 Dismantling of boarding, any description, fixed in position with nail 4 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 5 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type skelton door shutter of size 30mm thick open rebated and prepared to receive glass, gauge etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVCfoil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 6 S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 7 Ditto as per item No. 16 Above but of frame size 65 x 100 mm 8 Ditto as per item No. 16Above but of frame size 65 x 125 mm 9 Material and labour for providing kitchen cabinet and cubboard in required sizes at site made out of 18mm thick PVC sheet (prelam) having one side decorative laminated sheet (for shutter, sides of cabinet, partition and shelves etc). All the edges of shutter and front exposed edge of partition/shelves shall be covered with 2mm thick edge bonding tape as per manufacturer. Including all required fixing material such as SS brackets, screws, adhesive etc., including taking out old any type cabinet complete all as specified and as directed by Engineer-in-charge.Note :- (i) The area of each sheet (shutter, sides of cabinet, partition and shelves)shall be measured in sqm for payment. (ii)Magnetic catcher, handles, continuous Piano hinges and PVC frame (where required) shall be measured and paid separately under appropriate item of BOQ.(iii) Any other material required for making/fixing/hanging of cabinet shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 10 Material and labour for modular wardrobe cabinet shutter in required sizes at site made out of 18mm thick PVC sheet (prelam) having one side decorative laminated sheet for shutter fixed with and incl powder coated aluminium frame section/channel including PVC rollers,brass locking device and handle in each shutter. All the edges of shuttershall be covered with 2mm thick edge bonding tape as per manufacturer. Including all required fixing material such as SS brackets, screws, adhesive etc., including taking out old any type cabinet complete all as specified and as directed by Engineer-in-charge. 11 S & F 100 mm long butt hinges, medium weight, cold rolled mild steel and fixed complete/ 12 S&F 125 mm long Aluminium handle cast type anodized all as specified and directed by Engineer-in-Charge. 13 S&F 150 mm long Aluminium handle cast type anodizedall as specified and directed by Engineer-in-Charge. 14 S&F 150 mm long Aluminium anodized barrel tower bolt of extended section and fixed all as specified and directed by Engineer-in-Charge. 15 S&F 200 mm long Aluminium anodized barrel tower bolt of extended section and fixedall as specified and directed by Engineer-in-Charge. 16 S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing boltsand sliding bolts of extruded sections or cast aluminium alloy all as directed. 17 S&F Aluminium door stopper of any description all as specified and directed by Engineer-in-Charge. 18 S & F continous (Piano)type hinges mild steel bright finish or lectro galvanised with wide of flaps30mm complete all as spd and directed. 19 S&F magnet ball catcher for cupboard shutter, complete all as specified and as directed by Engineer-in-Charge 20 S&F 125 mm size hasp and staple,aluminium anodished,including bolt to hinge plate and fixed with screws,complete all as directed. 21 S&F in repair MS 300mm ordinaryrat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge. 22 S&F 25 mm dia Stainless steel drapery curtain rod, 25mm dia with decoative brackets,knobs,end stops etc and fixed to walls complete all as specified and directed by Engineer-in-Charge. 23 S & F4mm thick sheet glass ordinary quality and glazing with aluminium glazing beading clips not exceeding 0.50 sqm in each pane complete all as specified and directed by Engineer - in-Charge. 24 S & F 4 mm thick figured glass pin headed and glazing with aluminium glazing beading clips in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer - in-Charge. 25 S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanesed wire stapels complete all as specifed and directed. 26 S&Fpowder coated anodized aluminum frame for doors, windows , ventilators with one of more rebates including joining cleat for fixing etc. completed all as specified 27 S&F powder coated aluminum anodizedgrill diamond shape 100mm x 100mm aperture of 6 mm dia roundbars including necessary joining cleats, clips anodised complete all as specified. 28 S & Fpowder coated aluminum sliding window three track with frame & two glass shutter using 4 mm thick glass tinted modi guard and one shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperture 1.61 mm using aluminum powder coated section aluminum cleat , PVC track, bearing, handle lock rubber beading etc complete fittings as approved. Note :- Size of aluminum section shall be under – (i) three track top and vertical – jindal main 2010. Section No 20621 or equivalent as approved by GE.(ii) Three track bottom – Jindal main – 2010 section 20620 orequivalent as approved by GE.(iii)Shutter Vertical Section - Jindal main – 2010 section 20604 orequivalent as approved by GE.(iv) Shutter top and bottom - Jindal main – 2010 section 20604 orequivalent as approved by GE.(v) Shutter vertical middle ( interlock) - Jindal main – 2010 section 20605 orequivalent as approved by GE. 29 S&Fpowder coated aluminumWindow/Ventilators shutter side hung type without sash, aluminum section weighing glazed clips, rubber packing anodized aluminum fittings such as peg stays 150 mm long (1 nos)hinges type B-21 100 mm long (2 Nos) suitable handle (1 Nos) complete all as specified. 30 S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. 31 S&F 10mm thick PVC insulation panels with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing complete all as specified and directed by Engr-in-charge. 32 S&F of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame all as per specification and drawing. 33 S&F Solid PVC Wall Lining consisting of 5mm thicksingle side colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing 34 Demolation of ashlar facings, dressed stone work, stone slabs or tiles from paving and precast concrete blocks and articlesall as specified.& directed by Engineer -in-charge.. 35 M&L16-18mm thick granite (of any type ) work (table rubbed and polished ) in cooking platform and likein 15mm thick cm (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shed of granite. 36 M&L for 16mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. 37 Providing edge moulding to 16mm thick granitestone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete 38 M&L machine cut kota stone slab flooring 16-18mm thick in single piece over cement screed base laid and jointed with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing complete inculding screed bed or bedding layer of mortar 15 mm thick CM (1:6)all as directed by Engineer-in-Charge. 39 M&L forkota stone slab flooring 16-18mm thickin single piecein riser of steps,skirting,dado and pillar laid and jointed with grey cement mixed with pgment to match the shade of the slab including rubbing and polishing complete inculding screed bed or bedding layer of mortar 15 mm thick CM (1:6)all as directed by Engineer-in-Charge. 40 Cutting ,grinding ,cleaning and treating the surface of existing kota stone flooring with beeswax polishing complete as directed by Engr-in-Charge. 41 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), remving serviceable tiles to stores and and rubbish off the permises. 42 M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over and including 10mm thick cement sand plaster (1:3) complete all as specified and directed by Engineer - in - Charge. 43 M&L Non skid ceramic coloured /printed tiles 7 to 8 mm thick( square /rectangular ) joint free tiles area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shadeover and incl 15 mm thick rendering in CM 1:4 complete all as specified and directed by Engr in Charge. 44 M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tile shade complete all as specified and directed by Engr in Charge. 45 M&L vitrified ceramic coloured /printed tiles(HDVT) 10mm thick (square /rectangular ) joint free tiles area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shadeover and incl 15 mm thick rendering in CM 1:4 complete all as specified and directed by Engr in Charge. 46 M & L 20mm thick screed bed on concrete surfacesin CM 1:4 finished even & fair to receive floor tiles comlpete all as specified and directed by Engineer - in - Charge . 47 M & L rendering 10mm thick on fair faces of brick work or concrete surfacesin CM 1:3 finished even & fair to receive wall tiles comlpete all as specified and directed by Engineer - in - Charge . 48 Demolitionof cement concrete (un re-inforced) of any description in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge. 49 M & L 25 mm thick Cement Concrete 1:2:4 type B–0 using 12.5mm graded stone aggregates flooring finished even and rough to receive topping layer all as specified and directed by Engineer - in – Charge . 50 M & L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge. 51 Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed. 52 M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . 53 Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc. 54 M & L 10mm thick rendering in Cement Mortar 1:3 on fair facesof brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge . 55 M & L rendering 15mm thick on fair facesof brick work or concrete surfacesin CM 1:6 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge . 56 M & L rendering 15mm thick on fair facesof brick work or concrete surfacesin CM 1:4 mixed with water proofing compound 3%by weightof cement finished even & smooth without using extra cement ( WPC shall be measured & paid separately) cement all as specified and directed by Engineer - in - Charge . 57 Supply only liquid water proofing compound 58 Dismantling brick terracing tiles single layer from roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge. 59 Demolition/taking out of mud from roofs, any thickness, including removing / cutting uprooting grass,vegetations and roots of small plants etc on roof and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge 60 M & L for levelling coarse for roof slab,PainCement Concrete 1:2:4 (type B–0 using 12.5mm graded stone aggregates) for maintaining prooper slope and finishing the surface even and smooth complete all as specified and directed by Engineer - in – Charge . 61 M & L PCC 1:2:4, type B-1 , using 20mm graded stone aggregate as in kerbs or mud stops, rounded or chamfered on edges and similar work all as specified and as directed. 62 M&L forrendering10mm thick plasterin cement mortar (1:4) shall be provided mixed with water proofing compound, ISI markedas per manufacturer instructions. The plaster shall be steel toweled to get a smooth surface. 63 M&L for roof treatment as specified below and as directed -(a) Over the plastered surface apply one coat of compactible primer for PU coating as per manufacturer specification. Allow the primer to touch dry condition.(b) Apply first coat of PU coating (Shaliurethane @ LHM @650gm/Sqm (minimum) or equivalent) by brush/roller/spray, spread water proofing reinforced glass fiber Tissue of 150 GSM with overlaps of 75mmin both directions when the surface is still tacky. Alloow 1st coat to dry for 10-12 hr.(c) Apply 2nd and 3rd coat of PU membrane (Shaliurethane @ LHM @650gm/Sqm (minimum) or equivalent) as per as per manufacturer instructions having sun reflective index (SRI) of minimum 106 on top of roof surface after application. Extend water proofing treatment upto 200mm and terminate into groove on the parapet wall.Note :(i) The minimum thickness of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat.(ii) the plan area shall be considered for payment.(iii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicater approved by GE.(iv) trhe manufacturer/authorised applicator shall give a warranty for the performance and durability for 10 years. 64 Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided for. 65 M & L RCC 1:1½:3, (nominal mix), Type A-1, using 20mm graded aggregates as in chajjas, fins, fascias,shelves , louvers, parapets and railing etc and the like including necessary formworks all as specified and directed by Engineer - in - Charge. 66 S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia. 67 M&L for providing precast cement concrete louvres and jallies 1:2:4 type B-0, 25mm thick (measured solid) set in cement mortar 1:4, including all mould- ings but excluding frame complete all as specified and directed by Engr-in-Charge. 68 M&L 50mm thick PCC1:3:6 type C2 using 40 mm graded stone aggregate as in plinth protection, surface finished even smooth without using extra cement. 69 Dismantling of CI pipes or reinforced concrete pipes 100 mm dia fixed to wall etc complete all as specified and directed. 70 Dismantling of CI pipes or reinforced concrete pipes 75 mm dia fixed to wall etc complete all as specified and directed. 71 Taking down eves and gutter and rain water of any size all as specified and directed by Engineer - in - Charge . 72 S&F 110mm PVC (SWR) pipes single socketed(pressureratingnotlessthan 6kg/sqcm)in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. 73 Supply&fixing110mmborePVC(SWR)pipessinglesocketed(pressureratingnotlessthan 6kg/sqcm)inanylengthwithrubberringjointsfordrainorrainwaterfixedalongwallswithand including PVC clamps, complete all as specified and as directed by Engineer-in- charge. 74 Supply&fixing75mmborePVC(SWR)pipessinglesocketed(pressureratingnotlessthan 6kg/sqcm)inanylengthwithrubberringjointsfordrainorrainwaterfixedalongwallswithand including PVC clamps, complete all as specified and as directed by Engineer-in- charge. 75 S&F 75mm PVC (SWR) pipes single socketed (pressureratingnotlessthan 6kg/sqcm)in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. 76 Supply&fixingPVC(SWR)bends(anyradius)suitablefor110mmborepipecompleteallas specified and as directed by Engineer-in- charge. 77 Supply&fixingPVC(SWR)bends(anyradius)suitablefor75mmborepipecompleteallas specified and as directed by Engineer-in- charge. 78 Supply&fixingPVC(SWR)floortrap,plainwithgrating,suitablefor100/75mmborepipeincluding jointing with solvent cement complete all as specified and as directed by Engineer-in- charge. 79 Supply and fixing PVC (SWR) reducer 110/75 complete all as specified and as directed by Engineer-in-charge. 80 Supply & fixing PVC (SWR) vent cowl suitable for 75mm bore PVC pipe complete all as specifiedand as directed by Engineer-in- charge. 81 Supply & fixing 110mm bore PVC (SWR) junction single (single T) equal or unequal fixed with solvent cement, with access door complete all as specified and as directed by Engineer-in- charge. 82 S&F 110mm PVC(SWR) sanitary connection socket to fit out let of WC complete all as specified and directed. 83 Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store 84 Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store 85 S&F Chlorinated PVC (CPVC) pipes 20 mm outer dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.0 m spacing . this includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete all as specified and directed. Make : Supreme/Vectus or equivalent 86 Supply & fixing mild steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wallall as specified. 87 S&Fin repair gun metal globe or gate valve with iron wheel screwed both ends for iron pipe of 20 mm dia all as directed. 88 S&F 32mm bore for discharge pipe Bottle trap of stainless steel having minimum water seal of 25mm 89 S&F in repairs wall mounted vitreous china wash down water closet pan padestel pattern white including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern anti-syphonage pipe with PVC flush pipe of 32mm dia and including Jet spray and plastic seat cover with mild steel chromoum plated hinging and P or S trap device complete all as specified and directed by Engineer-in-Charge.Make ;- cat part No. ARS-WHT-0110 of Jaquar or equivalent as approved by garrison Engineer. 90 S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. 91 S&F in repair PVC concealed type flushing cistern set of capacity 10 ltr with half frame including all fixing accessories and knob fixed in wall and including flush pipe of PVC 32mm bore and connection to WC pan making good dismantled portion of wall complete all as specifed and directed. Make:Cera cat part No B1110112 or equivalent 92 S & F in repair vitreous china whitetable top wash basin of size185 x 490 X410 mm including brackets,waste fitting 32 mm brass chromium plated complete all as specified and as directed.Make ;- cat part No. FNS-WHT-0540 of Jaquar or equivalent as approved by garrison Engineer. 93 S&F PVC waste pipe 32mm dia & 90 cm long all as specified and directed by Engineer-in-Charge 94 S&F 600mm dia modular circular type beveled edge mirror of selected quality glass with touch screen pattern type lighting system fixed with brass screw and cup washes fixedin repaire complete all as specified and directed. 95 S&F in repair bib taps long body, 15mm bore dia, fancy type, cast copper alloychromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified. 96 S & F in repairs 15mm bore CP Angle cock one waychromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified . 97 S&F in repairs 15mmstop valves fancy type, chromium plated with long shank and cup (concealed type) ,cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed. 98 S & F in repair brass chromium plated central hole basin mixer with regular spout , popup waste system and 450mm long braided hoses with connection and nuts completeall as specified and directed by Engr-in-charge. 99 S & F in repairs brass chromium plated wall mixer with telephonic shower arrangement incl with CP 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in positionfor mixing hot and cold water screwed down for iron pipe and fixed as directed by Engr-in-charge : Make : Jaquar/ESS ESS/Prayag or equivalent. 100 S& F in repairs for brass chromium plated over head shower rose oval shape single flow 300 x 200 mm size with swivel joint including fixing to 15 mm dia steel pipe or union.Make :Cat part No. OHS-49497 ofJaquar or equivalent. 101 S & F soap dish holder brass chromium plated, fixed to plugs with brass chromium plated screws complete all as specified and directed by Engineer - in - Charge.Make ;- cat part No. AKP-35731P of Jaquar or equivalent as approved by garrison Engineer. 102 S & F soap dish dispenser with glass bottle brass chromium plated, fixed to plugs with brass chromium plated screws complete all as specified and directed by Engineer - in - Charge.Make ;- cat part No. ACN-1135N of Jaquar or equivalent as approved by garrison Engineer. 103 S & Fbrass chromium plated tubular towel rail 20mm dia “D” type 60 cm long between flanges incldg brackets complete all as specified and directed by Engineer - in - Charge .Make ;- cat part No. AKP-35711P of Jaquar or equivalent as approved by garrison Engineer. 104 S & F in repairs stainless steel towel rack with hook, mirror finish,polished,rust proof, foldable with multi purpose hooks (min. weight 1.5 Kg) complete all as specified and directed.Make ;- cat part No. AHS-1581H of Jaquar or equivalent as approved by garrison Engineer. 105 S&F CP stainless steel toilet paper holder complete all as specified and directed.Make ;- cat part No. AHS-1553 of Jaquar or equivalent as approved by garrison Engineer. 106 S & F in repairs glass corner shelf assembly fancy type made 8 mm thick sheet glass of size 300x300mm fixed with F or D type brass CP brackets complete all as specified.Make ;- cat part No. ACN-1173 of Jaquar or equivalent as approved by garrison Engineer. 107 S&F in repair CP grating suitable for 75/100 mm bore floor trap and fixed with white cement. 108 S&F in repair PVC connection both side brass unions internal for size 15mm dia and 600mm long all as specified and directed by Engineer-in-Charge. 109 Dismantling water tanks and removing to store of 500 ltr capacity 110 S&F rotational moulded polythene water storage tank (Cylindrical vertical withclosed top) hoisted and fixed in position of 500 ltrs capacity fixed with PVC tank nipples,complete all as specified in SSR Part I. 111 S&F in repair 20 mm float ball valve high pressire of PTMT with epoxy coated aluminium rod & high density platic ball screwed for iron pipe and fixed. ( Min weight 15 mm - 142 gms/20 mm 210 gms/25 mm 455gms/40mm 690 gms) 112 M & L for complete removal of existing treatment and applying two coats of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in - Charge . 113 M & L applying three coat of white wash on newly plastered or unplastered wall surface including preparation ofsurfaces, complete all as specified. 114 M & L for preparation of old surfaces by complete removal of existing treatment of painted walls incl pillar etc. by mechanical equipments like electric wall sander/water jet machine and applying a coat of cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturers specification complete all as specified and directed. 115 M & L for preparation of old surfaces by complete removal of existing treatment of painted ceiling incl beams etc. by mechanical equipments like electric wall sander/water jet machine and applying a coat of cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturers specification complete all as specified and directed. 116 M & L for preparation of old surfaces by complete removal of existing treatment of painted wall/ceiling incl pillar etc. by mechanical equipments like electric wall sander/water jet machine and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces complete, by mechanical means as per manufacturers specification complete all as specified and directed. 117 M & L for preparation of new surfaces of walls incl pillar etc. and applying a coat of cement based putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete, by mechanical means as per manufacturers specification complete all as specified and directed. 118 M & L for preparation of new surfacesof wall/ceiling incl pillars etc. and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces by mechanical means as per manufacturers specification complete all as specified and directed. 119 Material and labour for preparation of wall/ceiling surfaces and applying 1 mm thick cement based external wall care putty on old or new plaster surface complete all as specified and directed. 120 M&L for preparation of newplastered or concrete surfaces and applying two coats of weather proof exterior emulsion paint over a coat of exterior primer of approved shade on walls all as specified & directed by Engineer-in-Charge 121 M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge . 122 M & L forproviding and injecting chemical emulsion for post constructional antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.50 Ltrs per Sqm of the vertical surfaces of the sub-structure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete all as specified and directed. Note : Quantity will be measured perimeter of wall x depth of penetration. 123 Labour for disconnecting and taking out old unserviceable underground LT Cable any type alongwith stone patti/ cable cover/bricks/interlocking tiles etc from trenches/ floor/ road /pipe /along poles complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth workrequired for item shall be measured and paid separately under respective items of BOQ. 124 Supply, laying, Jointing and testingin trenches or fixing to wall/pole or passing through pipe and and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including making good to all disturbed surfaces/flooring/tiling/road to match with existing specifications complete all as specified and directed. 125 All per itemd No 124, but size 6 Sqmm 4 core 126 All per itemd No 124, but size 50 Sqmm 3.5 core 127 M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor with 80mm GI pipe complete all as specified and directed. 128 Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth for foundations of poles, struts, stays etc. or layingunderground cable etc.in soft/loose soil,& getting out complete all as specified and directed by Engineer-in-Charge. 129 Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge 130 Removal of excavated surplus material to a distance n. exc. 50 mtr away in layer n. exc. 25cm from the starting point all as direcet by Engr-in-Charge. 131 Supply and laying double wall corrugated pipe (DWCP) DWC Pipe dia 77/63, Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating,conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable complete all as specified anddirected by Engr - in charge 132 Supplying, fixing,testing,& commissioning intergal decorative Water proof 9 Watt LED bollard light with opal acrylic with IP-65 protection with inbuilt driver, colour temperature of 5700 K of graphite grey powder coated finish type including PCC base with specified size complete all as specified and directed by Engr-in-Charge. 133 S&F Post top lantern Light of 40 Watt capacity made of housing epoxy powder coated pressure die cast aluminium spigot and lid cover with graphite grey finish and clear acrylic cover, IP65 protction,including suitable mounting GI pipe to be fitted into the column / piller with allfitting and wiringand PCC grouting complete all as specified and directed 134 Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface all as spd and directed by Engr-in-Charge.Note: Rate for making good shall be deemed to be included in above item rate. 135 Taking down unserviceable main switches and MCB distribution boards single phase complete all as spd 136 Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 137 All as per Item No.136 above here in before but for One three pins 5 Amps switch socket outlet point on independent board with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 138 All as per Item No.136 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed.(socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 139 All as per item No.136 above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.(switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. 140 S & F modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. 141 S & Fmodular Socket outlet multipurpose type 6 Amp 2/3 pin combined, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. 142 S & Fmodular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. 143 S & F modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. 144 M&L for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked complete all as specified and directed. 145 S & F of MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 6 to 32 Amps all as specified and directed. 146 S & F of RCCBs suitable for 240 volts AC supply, double pole40A, 100mA with earth leakage protectionall as specified and directed. 147 S& F plug and socket type DB (Functional unit)20 Amps capacity with provision of single pole 20 amps MCB,plug top and earth plug,grouted flush to walls complete all as specified. 148 S&F Electric bell ding dong complete all as specified. 149 S & Fmodular Bell Push switch, 5Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be includedin point wiring item of BOQ. 150 S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed.. 151 S&F and testing LEDlight fitting 1x20watt 4 feet long including LED tube middle round shape with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. Make :- Bajaj, crompton & Havells 152 S&F for WEE Plus LED bulk head luminaire of capacity 10 Watt an ideal energy efficient solution for upgrading conventional GLS bulkhead luminaires to LED bulk head IP 65 complete all as specified and directed by Engr-InCharge 153 S & F aesthetic wall lamp of 15 W having warm white colour complete suitable for wall panelling including connecting up to with 3 core flexible conductor copper of suitable size complete all as specified and directed by Engineer-in Charge, 154 Supply and fixing bracket made out of GI tubing light grade 25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. 155 S&F for WEE Plus LED Bldg security light luminaire of capacity 35 Watt an ideal energy efficient solution for upgrading conventional GLS bulkhead luminaires to LED bulk head IP 65 complete all as specified and directed by Engr-InCharge :Bajaj, crompton & Havells 156 M&L forsubmain wiring comprisingsingle core ,2 Runs of 10 sqmm nominal cross sectional areamultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings/existing concealed conduit complete,including provision of 1 x 10 sqmm nominal cross sectional areamultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earthwirecomplete incl taking down old UNSV sub main all as specified.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) 157 Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of B class insulation, single phase, maximum 26W (± 10%), Temperature rise 40 degree maximum with remote, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 158 Supply and fix electric water heater, storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 litre,BEE 5 Star rated complete with all accessories such as safety valve,thermostate,NRV, connection piece etc all as specified 159 Supply and fixing Air freshener fanPVC body, AC single Phase 230V, 50 Cycle per second, copper winding of sweep size 250mmwith blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. 160 Supply and fixing Exhaustfan metal body body, AC single Phase 230V, size 300mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.5 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. 161 Supply and Fixing Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of size 20mm dia all as specified and directed Engr-in-charge. 162 S&F neon strip LED light of warm colour or desired colour with complete driver /connector/adaptor of suitablecap withpower input of DC 2V,6.5W/Mtr consumption and 3000K warm white and 6500K coolday light, 120 LED. 580 lumensper mtr, IP65surge cap upto 3.5KV approx with heat dessipation of length 50 Mtr roll incl all as specified and directed. 163 M&L for ceiling light fitting of skylux LED warm type efficient LED surface square type luminaire & galre free soft illumination of capacity 15 watt LED white/warm coliur complete suitable for roof ceiling including connecting upto with driver 3 core flexible conductor copper of suitable size complete all asspecified anddirectedby Engrin-charge. Make;- Bajaj, Crompton & Havells 164 S&F neon strip/profileLED light of warm colour or desired colour for Modular almirah with auto switch on /off with complete driver /connector/adaptor of suitablecap withpower input of DC 2V,6.5W/Mtr consumption and 3000K warm white and 6500K coolday light, 120 LED. 580 lumensper mtr, IP65surge cap upto 3.5KV approx with heat dessipation with all complete fitting all as specified and directed. 165 S&F 1.5 sqmm 3 core, 1100 volt grade heavy duty cable, PVC insulated copper multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for making connection Of bldg street lights/fan/garden lights complete all as specified and directed 166 Supply and fix light grade 50mm GI pipe fix complete to Wall , Poles etc with suitable clamp for protection of cable complete all as directed 167 Earthing complete with galvanised steel earth plate electroe 60 cmx60cm6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connectedto and including galvanized earth lead 4mm dia GI earth wire by means of GI bolt/snuts/washers, protected by 40mm bore GI light grade pipe from earth plate & upto 3m long pole fixed with 2 clamp made from mild steel flat iron 32x6mm bolts, nuts, washer etc. earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around buttom and top of earth plate 20mm dia GI Medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame PCC 1:3:6 type C1 using 20mm graded stone aggregate as in earthing pit including necessary excavation & earth work all as specified & shown on electrical plate No. 3 of SSR Part-I, (Note: (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner (ii) earthing for Lightning protection is also included in the above item) 168 Supply and fix LT Main control board of CRCA sheet metal board made out of 2.0mm thick and painting with 2 coats with synthetic enemel paint over a coat of red oxide primer including copper bus bar and fixed on/inside wall for fixing arrangement of existing smart meter incl internal connection with suitable size of copper conductor wire, and accessories, locking arrangement with opening handle (size not less than of box 120cmx100cmx35cm and adequate depth for the following equipments,internal wiring and termination of external cables, lugs and glands and conduit as required) including Taking down existing Old Unserviceable main control board comprising of following :- (a) Incoming :- MCCB 63 Amps, 4 Pole,415 Volts, 16 KA-01 No(b) Copper Bus bar 200 Amps for phase and neutral and earth bar(c) Out going MCB double pole 40 Amps - 2 Nos(d) Out going MCB SPN 10 Amps - 1 No
Contract Date: Nov 10, 2025 Contract Value : 16.54 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
38.
Public Administrative Department #10730816 Price Bid
Proposed Furniture Work At Kusumagraj Smarak In P.No.12 Nashik West Division.-1 COLLECTION counter Providing & fixing COLLECTION counter as per design of 0.9 m width & 1.2 in height with drawers above in 19mm thk. waterproof ply for frames, sliders & drawer facia,6mm thk. plywood for back & drawer bottoms with 12mm plywood for drawers, drawer side with bte lipping to all exposed edges of plywood including 1.mm thk. Laminate on top & 1mm thk laminate on sides & front of drawer facia & sliding shutters with necessary tower bolts castors handles, locks,etc.complete.with oil paint to all exposed surfaces of ply & lipping. Additional item Spec. no. as directed by Spec.No.: RA 22-23 A GROUND FLOOR 2 Providing and fixing vertical/roller blindes for window as approved by engineer in charge and architect GEM ID - 5116877-93262266948 Spec.No.: QUOTATION ATTACHED A GROUND FLOOR 3 GODREJ -ENTERPRIES TABLE 1200X600 X750 Enterprise 1200 Table without CPU Hanger size shall be 1200 Width mm x 600 Depth mm x 728 Height mm . Top shall be 18 mm thick Pre laminated particle board all work surface edges shall be having duly sealed with 2 mm thick PVC edgebanding. Understructure Modesty Panel 18 mm thick Pre laminated particle board . The Rectangular frame shall be fabricated component in 1.2 mm thick CRCA , Finish : powder Coat( epoxy polyster) . Leg shall be fabricated component in 38 mm x 25 mm 1.2 mm thick MS ERW ATube ,finish powder coat ( epoxy polyster).The plastic cap for cable travel shall be injection moulded polypropylene and leveler glide for shall be nylon 6 & MS bolt. The storage shall be having shell and drawer tray 0.6 mm thick CRCA Finish powder coat (epoxy polyster) plus the drawer front shall be 0.8 mm thick CRCA Finish powder coat (epoxy polyster) plus lock with 10 lever and handle and leveller. The wire management shall be horizontal wire carrier 0.7 mm thick CRCA Finish powder coat (epoxy polyster) and vertical wire carrier 0.8 mm thick CRCA Finish powder coat (epoxy polyster) . Spec.No.: AS PER QUTATION A GROUND FLOOR 4 GODREJ MAKE REVOVING CHAIR THRILL FULL BACK 1. SEAT/BACK ASSEMBLY: The back is made up of 1.2 ±0.1cm. thick hot-pressed plywood & seat is made up of 1.5 ±0.1cm. thick hot-pressed plywood measured and upholstered with fabric upholstery covers and moulded Polyurethane foam. The back foam is designed with contoured foam lumbar support. The seat has extra thick foam on front edge to give comfort to popliteal area .The Recron filling done in seat & back ( Executive chairs only) for extra fluffiness and comfort in chair. The chair seat & back size are *HIGH BACK SIZE 51.5 cm. (W) x 82.0 cm. (H) *FULL BACK SIZE 51.5 cm. (W) x 69.0 cm. (H) *SEAT SIZE 53.5 cm. (W) x 51.0 cm. (D) 2. HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam is moulded with density = 45±2 kg/m3 and hardness load 14 ± 2 kgf as per IS:7888 for 25% compression. 3. ARMRESTS (THRILL PLUS CHAIR) : The adjustable armrest is designed with the following features · Up-Down adjustment- 6 steps (7.2 ± 0.5cm range) · Armrest top is mounted on Armrest structure made of glass filled Nylon. · Armrest Top is PU moulded over glass filled Nylon insert. 4. CENTER TILT SYNCHRO MECHANISM WITH MULTI LOCK : The mechanism is designed with the following features: · 360° revolving type. · 3 position locking with anti shock mechanism. · Tilt tension adjustment 5. PNEUMATIC HEIGHT ADJUSTMENT : The pneumatic height adjustment has an adjustment stroke of 9.5 ± 0.3 cm 6. PEDESTAL ASSEMBLY ( THRILL PLUS) : The pedestal is injection moulded in black glass-filled Nylon and fitted with 5 nos. twin wheel castors. The pedestal is 66.1 ±0.5cm. pitch-center dia. (76.1 ±1.0cm with castors). 7. TWIN WHEEL CASTORS : The twin wheel castors are injection moulded in Black Nylon. WIDTH (W): 76.1 CM. DEPTH (D): 76.1 CM. HEIGHT (H): 113.5-123.5 CM. SEAT HEIGHT (SH): 46.0-56.0 CM. Spec.No.: AS PER QUTATION A GROUND FLOOR 5 GODREJ MAKE RELFEX CHAIRS WITH STACKEBALE TYPE 4 METAL LEG . SEAT / BACK ASSEMBLY : The Seat is injection moulded in glass filled Polypropylene compound which is upholstered with fabric upholstery covers and moulded Polyurethane foam. The Back is injection moulded in glass filled Polypropylene compound which is upholstered with Mesh fabric (Refer colour chart for seat & Back upholstery in product catalog). * SEAT SIZE : 50.0cm. (W) x 48.0 cm. (D) * BACK SIZE : 53.0 cm. (W) x 39.0cm. (H) 2. HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45±2 kg/m³ and hardness 16±2 kgf as per IS:7888 for 25% compression. 3. M.S. POWDER COATED FRAMES FOR 4 LEG CHAIRS :The powder coated ( DFT50±10 microns) welded tubular main frame is made from Ø 2.54 ± 0.03 cm x 0.2 ± 0.016 cm andØ1.6±0.3mm x 0.16 ± 0.0128cm M.S. E.R.W tube. The Ø1.9 ±0.3mm x 0.12 ±0.0096 cm M.S.E.R.W. tube used as connecting member between LH & RH frames. Desk let support frame is made from Ø 2.22 ± 0.03 cm x 0.16 ± 0.0128 cm and welded to mainframe. Spec.No.: AS PER QUTATION A GROUND FLOOR 6 GODREJ MAKE GAIN 8 FT HIGHT GLASS DOOR BOOK RACK- 2325 H x 900 W x 450 D GAIN PRO STORAGE (BOOK RACK) 2325 H x 900 W x 450 D EACH UNIT SIZE Construction & Material - Aesthetically appealing completely knock down construction. The add-on units are stack widthwise to form arow of storage.(Note- Single Main unit should not be offered. Minimum 1Main + 1Addon to be offered)Legs fitted with screw type leveler.Made from combination of Top panel(0.5mm CRCA), side panel(0.5mm CRCA), Bottom panel(0.5mm CRCA for 450W/600W and 0.8mm CRCA for 900W/1200W), Back panel(0.5mm CRCA), Top Bottom stiffener(1.2mm CRCA) and End Cover(0.5mm CRCA). ** - CRCA D Grade as per IS-513Shelving - It is a 12 bend panel made of 0.7mm Thick CRCA (D Grade, IS-513) Each shelf has max Load Capacity of - 4 Nos. of fixed shelves for 1950(H) A4 size Box file (85Wx340Hx285D) can be stored vertically on all loading levels (Refer Sheet 4 of 17) Number of files that can be stored in one shelf is as follows: Finish - Epoxy Polyester Powder coated to the thickness of 50 microns (+/-10 micron). Construction & Material - Made from 0.6mm Thick CRCA (D Grade, IS-513) Soft closing Hinge Handle - Asthetically appealing handle made of Aluminum Cam Lock -3 Way locking provision. Click action mechanism. #NAME? positions. Zinc alloy die cast housing. Finish - Epoxy Polyester Powder coated to the thickness of 50 microns (+/-10 micron).Material to be supplied by certified ISO 50001:2018, ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, ISO 13485:2016, AIOTA member. Item should have at least one of the GRIHA/GREENGAURD/GREENPRO/ GREEN ASSURANCE Certifications adhering to standard environmental practices. Valid test certificate should be available for the item under consideration. Also, OEM must have dedicated toll free service number. Spec.No.: AS PER QUTAION A GROUND FLOOR 7 UPBEAT Discussion Table without wire manager-Size-900 Dia.750H MM Upbeat is a Complete office Furniture setup solution, designed to cater to the various settings in an office space.19mm thick both sided laminated MDF top Metal leg with epoxy powder coating Spec.No.: AS PER QUTATION A GROUND FLOOR 8 Excavation for foundation in earth, soil of all types, sand,gravel and soft murum, including removing the excavatedmaterial up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering,preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc.complete. (Lift upto 1.5 m.) By Mechanical Means Spec.No.: Bd.A.1 PageNo. 259 I.NO 21.0 2 A GROUND FLOOR 9 Excavation for foundation in hard murum includingremoving the excavated material upto distance of 50metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming,watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No.: Bd.A.2 PageNo.269 I NO 21.0 6 A GROUND FLOOR 10 Filling in plinth and floors with Contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec.No.: Bd.A.11 Page 253 21.37 A GROUND FLOOR 11 Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Spec.No.: Bd.A. 12 PAGE 254 21.38 A GROUND FLOOR 12 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.: Bd.E.4 Page No. 289 and B-7, Page No.38 I.NO.24.08 A GROUND FLOOR 13 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.: Bd.F.6 Page No. 300 and B.7, Page No.38 I.NO.25.50 A GROUND FLOOR 14 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering,ormwork, cover blocks,laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.: Bd.F.8 Page No. 302 and B.7, Page No.38 I.NO.25.70 A GROUND FLOOR 15 Providing and laying Cast in situ/Ready Mixcement concrete M20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.: Bd.F.9 Page No. 303 and B.7, Page No.38 I.NO.26.05 A GROUND FLOOR 16 Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec.No.: Bd. F. 12 Page No. 304 and B -7, Pg 38 I.NO.26.23 A GROUND FLOOR 17 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps,footings, foundations, slabs, beams columns, canopies,staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules.including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec.No.: Bd.F.17, Page No.306 I.NO.26 0.33 A GROUND FLOOR 18 Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Spec.No.: As director by engineer in c harge and BDG- 2 and 5 I.NO.27.12 A GROUND FLOOR 19 Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Spec.No.: As director by engineer inch arge and BDG- 2 and 5 I.NO.27.13 A GROUND FLOOR 20 Providing uncoursed rubble masonry of trap / granite /quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually, striking joints on un exposed faces and watering etc.complete. Spec.No.: Bd.H.1 Page No.329 I.NO.28.0 1 A GROUND FLOOR 21 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec.No.: As directed by Engineer in c harge. I.NO. 31.04 A GROUND FLOOR 22 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete. Spec.No.: Bd. L.2 Page No. 368 I.NO.32 0.03 A GROUND FLOOR 23 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec.No.: Bd.L.7 Page No. 369 I.NO.32. 11 A GROUND FLOOR 24 Providing neeru finish to plastered surfaces in all positions including. Spec.No.: Bd. L.10, Page 370 I NO. 32. 15 A GROUND FLOOR 25 Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Spec.No.: Bd.M. 12 Page No.385 I.NO.33 0.42 A GROUND FLOOR 26 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Spec.No.: Bd.M. 12 Page No.385 I.NO.33 0.43 A GROUND FLOOR 27 Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. Spec.No.: As directed by Engineer in c harge. I.NO.35.25 A GROUND FLOOR 28 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. Spec.No.: Bd.P.6 Page No. 414 I.NO.36. 12 A GROUND FLOOR 29 Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kgs/M2 and minimum pull out strength of 100 Kgs.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Spec.No.: As directed by Engineer in c harge. I.NO.38.45 A GROUND FLOOR 30 Providing and fixing frame with / without ventilator of size as specified with Country non teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec.No.: As directed by Engineer inch arge. I.NO.39.02 A GROUND FLOOR 31 Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing without hot dip zinc coating including fabricating glazing with plain / obscured glass panes 5 mm thick and approved type and quality and iron oxidized fixtures and fastening oil paint 2 coats etc. complete. Spec.No.: BD-T-53 Page No. 509 As dire cted by Engineer in charge I.NO.39.29 A GROUND FLOOR 32 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm . Spec.No.: As directed by Engineer in c harge. i. no.39.56 A GROUND FLOOR 33 Providing and fixing 30mm thick PVC FLUSH L DOOR SHUTTER consisting of panel of hollow PVC profile of 20 mm thickness consisting frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mminserted inside the hollow section of stiles rails top ?and bottom rails and two 19x 19 mm MS tubes inserted horizontally inside the hollow profile section using 4/5 mm sheet using screws hollow profile shall be lipped with 10 mm (5mm x2) thick x 20 mm width on stiles and rails using solvent cement. The inner panel shall be laminated with 5mm thick termite proof waterproof plain /prelam PVC sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening etc. Complete as per direction of Engineer incharge, manufacturers specification and drawing. Spec.No.: As directed by Engineer in c harge. i. no.39.82 A GROUND FLOOR 34 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Spec.No.: Bd.V.8 Page No. 554 I.NO.41. 400 A GROUND FLOOR 35 Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete. Spec.No.: Bd.V.9 Page No. 555 I. NO.41 0.48 A GROUND FLOOR 36 Providing and fixing 15mm diameter concussion push button type brass/gun metal self-closing tap including necessary socket complete. Spec.No.: Bd.V.14 Page No. 557 I.NO.41 0.52 A GROUND FLOOR 37 Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe. Spec.No.: Bd.V.23 Page No. 562 I. NO.4 1.57 A GROUND FLOOR 38 Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. Spec.No.: Bd.V.30 Page No. 565 I. NO.4 1.63 A GROUND FLOOR 39 Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and Spec.No.: BdV41 PAGE NO 573 I NO 42.07 0 A GROUND FLOOR 40 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75 kg with lid and frame fixed in cement concrete. Spec.No.: Bd.V.43,Page No.574 I.NO.42. A GROUND FLOOR 41 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Spec.No.: As directed by Engineer inch arge. I.NO.42.200 A GROUND FLOOR 42 Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Spec.No.: As directed by Engineer in c harge. I.NO.42.320 A GROUND FLOOR 43 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as direc ted by Engineer in charge I.NO.42.550 A GROUND FLOOR 44 Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec.No.: BD.V 5 page 551 and as direc ted byEngineer in charge I.NO.42.580 A GROUND FLOOR 45 Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Spec.No.: BD.V 5 page 551 and as direc ted by Engineer in charge I.NO.42.600 A GROUND FLOOR 46 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. Spec.No.: BD.V 32 A page 551 and as di rected by Engineer in charge I.NO.42.670 0 A GROUND FLOOR 47 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. Spec.No.: As directed by Engineer Inch arge I.NO.42.860 A GROUND FLOOR 48 CARTING UN WANTED MATERIAL FROM SITE UP TO 5 KM Spec.No.: AS DIRECTED (LEAD CHRGES FOR 5 KM) A GROUND FLOOR 49 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. Spec.No.: As directed by Engineer inch arge. I.NO.46.090 A GROUND FLOOR PART B (ELECTRICAL) 1 Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories (PWD DSR 2023-24, 1-7-18) 2 Point wiring for ceiling fan in PVC trunking (casingcapping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories (PWD DSR 2023-24, 1-7- 19) 3 Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories (PWD DSR 2023-24, 1- 7-20) 4 Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories (PWD DSR 2022-23, 1-7-25) 5 Providing and fixing PVC trunking (PVC casing-ncapping) of size 25 mm with accessories on wall/ceiling (PWD DSR 2023-24, 1-2-7) 6 Providing and fixing HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling (PWD DSR 2023-24, 1-2-4) 7 Concealing of provided G.I. pipe/H.G. screwed conduit/PVC pipe in wall/floor/false ceiling (PWD DSR 2023-24, 1-1-13) 8 Providing and fixing mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking (PWD DSR 2023-24, 3-1) 9 Providing and fixing mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking (PWD DSR 2023-24, 3-2) 10 Providing and fixing mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking (PWD DSR 2023-24, 3-3) 11 Providing and fixing LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete (PWD Elec 2023-24, 2-1-18). 12 Providing and fixing LED square / circular Max. W down lighter / Panel Light having pressure diecast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens,(PWD DSR 2023-24, 2-1-5) 13 Providing and fixing LED Panel Light (600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, etc complete (PWD DSR 2023-24, 2-1-5) 14 Providing and fixing Ceiling fan 230 V A.C. 50 cycles 1400 mm etc complete (PWD DSR 2023- 24, 2-9-3) 15 Providing and fixing modular type electronic step regulator for fan etc complete. (PWD DSR 2023- 24, 2-10-9) 16 Providing and fixing fan clamp of 30 x 5 mm. M. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. (PWD DSR 2023-24, 2-10- 3) 17 Providing and fixing ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected (PWD DSR 2023-24, 2-10-6) 18 Providing and fixing bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator (PWD DSR 2023-24, 2-9- 19 Providing and fixing exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials (PWD DSR 2023-24, 2-9- 13) 20 Providing, fixing and marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board (PWD DSR 2023-24, 5-3-3) 21 Providing, fixing and marking DPMCB 40A to 63A, B- series (for lighting) in provided distribution board (PWD DSR 2023-24, 5-3-9) 22 Providing, fixing single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs (PWD DSR 2023-24, 5-4-7) 23 Providing and fixing single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, (PWD DSR 2023-24, 5-4-9) 24 Providing, fixing testing and commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 5.00 suitable operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete (PWD DSR 2023-24, 3-2-9) 25 Providing, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete(PWD DSR 2023-24, 3-2-13) 26 Providing and fixing PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to kV (PWD DSR 2023-24, 1-3-15) 27 Providing and fixing copper pipe suitable for refrigeration system having size 12 mm complete. (PWD DSR 2023-24, 3-2-26) 28 Providing and fixing bracket for split type AC 29 Providing and fixing copper pipe suitable for refrigeration system having size 16 mm complete. (PWD DSR 2023-24, 3-2-27) 30 Providing and fixing Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm (PWD DSR 2023-24, 4-2-3) 31 Providing and fixing Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm (PWD DSR 2023-24, 4-2-4) 32 Providing and fixing rigid PVC pipe 20 mm dia.with PVC accessories for drain (PWD DSR 2023-24, 1-2-3) 33 Providing and fixing meter box with all accessories complete. 34 Providing, laying and terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe (PWD DSR 2023-24, 7-1-28) 35 Providing, fixing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials and recording the results (PWD DSR 2023-24, 9-1-1) 36 Providing and fixing GI earth wire of high purity of different sizes used for earthing. (PWD DSR 2023- 24, 9-2-5)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Maharashtra View Result →
41.
Public Administrative Department #10714170 Price Bid
Civil Work For Auditorium For Nagar Parishad, Dausa, Rajasthan Civil Work For Auditorium For Nagar Parishad, Dausa, Rajasthan EARTH WORKClearing Grass and Removal of Rubbish (Maximum 150mm) by manual means and disposal at a lead of 50 metres as per MoRT&H specification clause 201. 2 Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). In all type of soil. Upto 3.0 m depth. 3 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m. 4 Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.1.1 5 In ordinary rock. Depth upto 1.5 M. 6 Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.2.1 7 Carriage of Materials by mechanical transport including loading, unloading and stacking ::Upto 1 Km 8 Stone, boulders, gravelly materia 9 Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. 10 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion). 11 Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRT&H specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification including all material, labour, machinery as per clause 710.1.4 of IRC:78 and clause 2200 of MoRT&H specification. 12 CONCRETE WORK 13 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 14 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 15 REINFORCED CEMENT CONCRETE 16 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix). 17 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement :1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix) 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-30 Grade Concrete. 19 Reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15° upto two stories excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 20 Providing and laying upto two stories reinforced cement concrete in kerbs, steps and the like excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 21 Add extra for laying reinforced cement concrete above two stories (or 7.50 mtr height above plinth level) for every one storey or 3.00 m height or part thereof. 22 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 23 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 24 Suspended floors, roofs, landings, balconies and access platform. 25 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 26 Columns, Pillars, Piers, Abutments, Posts and Struts.22.1.5 27 Stairs, (excluding landings) except spiral-staircases. 28 Extra for shuttering in circular work (20% of respective centring and shuttering items). 29 Edges of slabs and breaks in floors and walls. Under 20 cm wide. 30 Weather shade, Chajjas, corbels etc., including edges. 31 Add extra for doing centering and shutteriing work for every additional height of 1 metre or part thereof beyond initial 7.5 metre height from plinth level. 32 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. 33 BRICK / STONE MASONERY WORK 34 Brick work with FPS bricks of class designation 75 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand). 35 Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand). 36 Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:3 (1 cement :3 coarse sand). 37 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 38 Random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of MoRT&H specification including all scaffolding material, labour, machinery but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand). 39 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Green / Black Above 3601 Cm2 Slabs. 40 Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work. Moulding. 41 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 42 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 43 Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles 44 Providing and fixing Motive pieces all coloures for glazed tiles laid over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shade complete. Size 200 x 300mm. 45 P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm. 46 Providing and fixing 1st quality MAT & GLOSSY finished ceramic tiles colour such as standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the the cost of cement mortar bed 1:4) Size 300mm x 450mm. 47 Providing and fixing 1st quality ceramic glazed vitrified tiles of colour standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete. (excluding the the cost of cement plaster on wall and pillar). Size 600mm x 1200mm 48 38mm thick wood block flooring of first class teak wood laid over 25mm thick levelling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10mm nominal size) to be paid separately coated with a thin layer of hot bitumen (blown type) @ 2.45 kg per sqm. including fixing blocks in position after dipping in hot bitumen (blown type) upto half depth, planed, levelled smooth and finished complete. 49 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 50 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Red sand stone. 51 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 52 ROOFING 53 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75mm deep chase. 54 Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80mm thick with zinc coating not less than 275gm/m². 55 Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimetre 0.80 mm thick 56 Providing and fixing 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.80mm thick with zinc coating not less than 275gm/m² 57 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine/ coarse sand) 58 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand). 59 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 60 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 61 18 mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) toplayer 6mm thick with cement mortar 1:4 (1 cement : 4 fine sand). Design on outer plaster. 62 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 63 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 64 Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). 65 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work. 66 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 67 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8193, density 16kg/m3 , 50mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire. 68 Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving screws, over expansion joints on vertical surfaces/ceilings with full threaded, cadmium plated steel screws 4mm dia. stem, 30mm long and aluminium washers 2mm thick, 15mm dia. at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete. Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron). 69 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width. 70 Providing and laying expansion joint complete as per drawing and technical specification and as per clause 2605 of MoRT&H Specification including all material, labour, machinary etc. 71 Fillar joint with 20m thick compressible fibre board. 72 Fillar joint with Joint sealing compound with coarse sand and 6 %bitumen by weight. 73 Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: Hot finished seamless type tubes. 74 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 75 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C 76 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S. tube. 77 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 78 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure A : 30 mm thick Decorative teak veneer both side. 79 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured). Decorative teak veneer both side. 80 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) Rectangular or square. 81 Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area ofthe shutter to be measured). 82 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 50 mm long. 83 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 20 mm dia. 84 Providing and fixing to existing door frames. 30mm thick factory made solid both side Pre-laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded Pre-laminated PVC C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side Pre-laminated PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification & drawing (for W.C. and bathroom door shutter). 85 ALUMINIUM WORK 86 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). 87 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron). 88 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 25 mm thick 89 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basicitem) : With float glass panes of 5.50 mm thickness. 90 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate. 91 Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin-charge complete. 355 X 19 mm. 92 INTERIOR WORK 93 FALSE CEILING 94 Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part I, 95 Sanitary Items 96 Plumbing 97 Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour. 98 15 mm nominal bore with 3 cm length. 99 15 mm nominal bore with 45 cm length. 100 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. 101 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 102 15 mm nominal bore 103 20 mm nominal bore 104 25 mm nominal bore 105 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 106 25 mm nominal bore Horizontal 107 25 mm nominal bore Vertical 108 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 109 Sanitary 110 Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : Upto 300 mm dia. 111 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : 112 100 mm dia. pipe 113 125 mm diameter pipe 114 Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead : 115 100 mm diameter pipe 116 125 mm diameter pipe 117 Supplying pig lead at site of work. 118 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter 119 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 120 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With bricks with class designation 75 121 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With bricks class designation 75 122 Providing and fixing square-mouth S.W. gully trap grade A’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With bricks class designation 75. 123 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design With bricks. 124 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design With bricks 125 Fixtures 126 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. 127 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated levers. 128 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm. 129 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 130 Rectangular shape 453x357mm 131 Rectangular shape 1500x450 mm 132 Providing and fixing 100 mm sand cast Iron grating for gully trap 133 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 134 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 100 mm outlet 135 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 mm nominal bore 136 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. 137 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-incharge and finished smooth. Granite Stone of approved shade 138 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 139 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. 140 Internal work - Exposed on wall 15 mm dia. nominal bore 141 Internal work - Exposed on wall 20 mm dia. nominal bore 142 Internal work - Exposed on wall 25 mm dia. nominal bore 143 Internal work - Exposed on wall 32 mm dia. nominal bore 144 Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 15 mm dia. nominal bore 145 Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 20 mm dia. nominal bore 146 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 147 15 mm dia. nominal bore 148 20 mm dia. nominal bore 149 25 mm dia. nominal bore 150 32 mm dia. nominal bore 151 Painting G.I. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work : 152 15 mm dia. nominal bore 153 20 mm dia. nominal bore 154 25 mm dia. nominal bore 155 32 mm dia. nominal bore 156 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 157 15 mm dia. nominal bore 158 20 mm dia. nominal bore 159 25 mm dia. nominal bore 160 32 mm dia. nominal bore 161 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 162 15 mm nominal bore 163 20 mm nominal bore 164 25 mm nominal bore 165 WATER HARVESTING SYSTEM 166 Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes but excluding cost of casing pipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 200 mm dia Nominal bore 167 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985 of following nominal bore sizes at site of work. 200 mm dia 168 Supply and fixing of M.S. clamp set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 169 Providing & lowering of G.I. flange pipe B Class including rubber washer and nuts of 8 mm dia complete in all respect. 50 mm dia 170 Development of tube well as per IS specification using suitable compressor to give sand free water for required yield of the gravel packed tube well. 171 ELECTRICAL G-SCHEDULE 172 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its accessories, round tiles,18 SWG M.S. box with earth terminal, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 173 Short point (up to 3 mtr.) 174 Medium point (up to 6 mtr.) 175 Long point(up to 10 mtr..) 176 Wiring of twin control light / fan / call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its accessories, round tles,18 SWG M.S. box with earth terminal, 6 A two way switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 177 Short point (up to 3 mtr.) 178 Medium point (up to 6 mtr.) 179 Long point(up to 10 mtr..) 180 Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm FR PVC insulated unsheathed 1.1 kV grade flexible copper conductor and 1.5 sq.mm FR PVC insulated unsheathed 1.1 kV grade copper earth conductor (IS:694) of approved make double lock/ ISI marked single lock pvc casing capping & its accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & falce ceiling point, 6 A switch, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 181 On board 182 Short point (up to 3 mtr.) 183 Medium point (up to 6 mtr.) 184 Long point(up to 10 mtr..) 185 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required. 186 20 mm 187 25 mm 188 32 mm 189 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 190 3x 1.5 sq.mm 191 2 x 2.5 sq. mm. + 1x1.5sqmm 192 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 193 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 194 4 x 10.0 sq.mm 195 4 x 16.0 sq.mm 196 Supplying and drawing PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable of approved make in existingsurface or recessed conduit/casing capping including making connections as required. 197 RG - 6 198 RG -11 199 Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped &confirming to ITD specification S/WS-112C &113 C of approved make in existing surface or recessed conduit/casing capping. 200 Unarmoured 2 pair 201 Unarmoured 10 pair 202 Unarmoured 20 pair 203 Unarmoured 50 pair 204 Jelly filled armoured (PIJF) 5 pair 205 Jelly filled armoured (PIJF) 10 pair 206 Jelly filled armoured (PIJF) 20 pair 207 Jelly filled armoured (PIJF) 50 pair 208 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar masking sheet conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. Double door (Three phase) Per phase isolation 209 2+8 Way 210 2+12 Way 211 Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 212 2.5 Sq. mm 4 core 213 4.0 Sq.mm 4 core 214 6.0 Sq.mm 4 core 215 10.0 Sq.mm 4 core 216 16.0 Sq.mm 4 core 217 25.0 Sq.mm 3.5 core 218 35.0 Sq.mm 3.5 core 219 50.0 Sq.mm 3.5 core 220 70.0 Sq,mm 3.5 core 221 95.0 Sq.mm 3.5 core 222 120.0 Sq.mm 3.5 core 223 150.0 Sq.mm 3.5 core 224 240.0 Sq.mm 3.5 core 225 300.0 Sq.mm 3.5 core 226 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 227 3.5 x 25.0 sq.mm 228 3.5 x 35.0 sq.mm 229 3.5 x 50.0 sq.mm 230 3.5 x 70.0 sq.mm 231 3.5 x 95.0 sq.mm 232 3.5 x 120.0 sq.mm 233 3.5 x 150.0 sq.mm 234 3.5 x 240.0 sq.mm 235 3.5 x 300.0 sq.mm 236 4 x 2.5 sq.mm 237 4 x 4.0 sq.mm 238 4 x 6.0 sq.mm 239 4 x 10.0 sq.mm 240 4 x 16.0 sq.mm 241 Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. Hot Dipped Galvanized. 242 150mm x 50mm x 1.6mm 243 300mm x 50mm x 1.6mm 244 450mm x 50mm x 2.0mm 245 600mm x 50mm x 2.0mm 246 Maintenance free gel earthing with pipe in pipe /Strip in Pipe technology filled with anti corrosive conductive compound (CPRI tested) below the ground in 150 -200 mm dia earth pit and surrounding filled with required mineral filling compound (MFC should have hygroscopic proper ty to retain the moisture for long time to create low resistance Zone) and C.C. finished chamber covered with hinge type with locking arrangement C.I cover. C.I. frame of size 300mm x300mm complete testing of earth resistance as required of following sizes With pipe in pipe technology (inner pipe dia / outer pipe dia) 80 -100 micron G.I. coating With pipe in pipe technology with 80-100 micron G.I. coating G.I. pipe 3000 mm long , 80/40 mm , terminal 14 mm G.I. strip 247 S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 248 8 SWG copper Wire 249 25mm x 3mm copper strip 250 50mm x 6mm copper strip 251 25mm x 3mm G.I. ( Hot Dipped) Strip 252 25mm x 6mm G.I. ( Hot Dipped) Strip 253 P & F of IP20 LED Recessed/ Surface Mounted Round/ sqaure Non Dimmable Downlight with die-cast aluminum housing & Heat sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to IEC standards. ( supplied together with luminaire) Power consumption of =< 7w/10w/8w/12w/15w/18W with 100/500/750/1100/1250 lumens, system lumen, efficeancy of 70 lm / Watt or 100 lm / Watt output suitable to replace 1x18W/ 2x18w/2x26w CFL downlights, life time of 50000 Burning Hours with 70% of intial Lumen maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be CE Compliance. 254 Recessed mounting LED Downlight 18/20W 255 Surface Mounting LED Downlight 18/20W 256 P & F of IP20 LED Ceiling/ Recessed/ suspended mounting light fixture made form CRCA sheet steel housing, high purity/ transmisivity diffuser for uniform light distrubution.High efficiency driver electronics having efficiency > 85% and in compliance to IEC standards.(integral driver). Power consumption of 40 W/50W/60W, 3000/3300/4200 lumens, system lumen efficiency of 70-80 lm / Watt output suitable for 2x36W FTL/ 2x36w CFL/3x36w CFL light fixtures, life time of 50000 burning Hours with 70% intial Lumens maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be CE compliance. Surface Mounting 36W LED Light 2’x2’ with acrylic/ prismatic front cover 257 P & F energy efficient direct fit (Retrofit) LED tube system (with integral driver), on existing fixture. Power Consumption of18W / 36W 1500-3000 lumens, system lumen efficiency 80 lm/Watt output, life time of 50,000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K& 6000°K. 4 LED Tube shape fixture 18W. 258 P/ F IP-65/ IP-66 protected street light luminaries on existing bracket. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance. IP-65 protected LED street light luminaries LED street light fixture 150 watt 259 Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. 9 Mtr. 260 Supply, Installation, Testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer (+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5% of the maximum total loss values for 11 KV as per energy efficiency level - 2 at basic Insulation level conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014. Transformers described as above and as per the following continuous rating. 315KVA 261 Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 11 KV Incomer VCB panel up to 630 A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 25KA/3 and IAC A-FLR for 25kA/1sec. Make of HT Panel, Vaccum Interrupter and VCB should be of same make. 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-12 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer, Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core dual ratio 3CTs of suitable ratio with sec 1 of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection, Multifunction Meter. 262 SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.Alternator shall be self regulated with standard Alternator Protection( Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping , electronic / Mechanical governor, Manual & electric Start, Batteries, Fuel tank ( with Stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183 .The doors are fabricated from 1.6 mm CRCA sheet packed with accoustic material, floor of MS chequrred plate 5.0 mmthick, All doors/ opening are sealed with neoprene/ EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 °C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system mccb Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. Lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 db (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity : Radiator cooled and turbo charged 250 KVA at 0.8 pf 415V 50Hz 3-?. 263 Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: (i) Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii) Provision for fixing of combined CT PT Set (To be supplied by DISCOMs) (iii)TT Block (iv) 6mm Bakelite sheet on all sides. 264 Supply, Installation, testing and commissioning of 11 KV Double Pole structure With Air Break SWITCH having following specifications : (a) DP : Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required. (b) GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3 phase, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 Nos pin insulator ,GI pipe of suitable length for operation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Post insulators. (c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators (d) LA:3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. (e) JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ 265 FIRE ALARM G-SCHEDULE 266 SITC of microprocessor based 2 - wire loop (each loop accessing 90 addressable units ) Fire Alarm Control Panel. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. The Panel shall also be able to give voice announcement to individualized speakers. The Panel shall have built in sounder, Maintenance Free Batteries of minimum 15 Ah of 24 volts capable of minimum of 12 hours with battery charger, rectifier. Loop cards, LCD unit to indicate Fire / Fault Signal of individual unit, built in-built / external printer, to log all incoming data etc complete in all respect. 2-LOOP. 267 SITC Manual Call Point complete with , Glass, hammer and chain etc as required: Analogue addressable type 268 SITC Automatic commendable Control Switches for shutting downAC Plant, Power Supply, Gas Supply etc. Response Indicators. 269 SITC Fault Isolators for isolating shorted, dead wire and loose circuits between two successive Fault Isolators with automatic resetting arrangement. Analogue addressable type. 270 FIRE FIGHTING G-SCHEDULE 271 Sub Head - I - (Wet Riser System - Pumping Equipments)SITC of electric driven Sprinkler / Hydrant pump Suitable for automatic Operation consisting of the following-(A) Horizontal multi stage Centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary sluice value on the suction side ( all items to be matching the suction side of the pump) and pressure gauge sluice value and non return valve on the delivery side side ( all of the necessary dia) and including bypass arrangement for testing of pump.(B) Squirrel cage induction motor suitable for 415 V, 50 HZ, Ac supply of below mentioned HP for the above pump ,1450 RPM T.E.F.C confirming to IP:55 and flexible coupling and coupling guard with the pump. (C) Common bed plate fabricated from mild steel channel or cast iron type1620 LPM at 70 Mtr Head ( 50 HP Motor) 272 SITC of diesel engine drive Standby Pump suitable for automatic operation consisting of the following A, B, C. .The Diesel driven pump shall be suitable for following discharge:(A) Horizontal multi stage centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary flexible pipe, sluice value on the suction side (all items shall be matching the suction side of the pump) and pressure gauge, sluice valve and non return valve on the delivery side (all of the necessary dia) and including bypass arrangement for testing of pump.(B) Water cooled Diesel Engine developing suitable BHP for the below mentioned discharge at 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump, d cushy foot, damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically with a unit of battery of 12/24v, 88 Ah, 13/21 plate, Exhaust Pipe of minimum 10 M length, with muffler, day oil tank of 300 1ts capacity with first charge and hand operated oil pumpingset, Supply, installation, testing, & commissioning of electric driven automatic pressurization pump setC) Horizontally mounted single stage centrifugal end delivery pump of below mentioned discharge with necessary sluice valve on the suction side (all items matching the suction side of the pump) and sluice valve, non return value, pressure gauge on the delivery side including by pass arrangement for testing of the working of the pumping set as required.1620 LPM at 70 Mtr Head ( 50 HP Engine) 273 SITC of Jockey pump having Squirrel cage induction motor suitable for 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM T.E.F.C type confirming to IP:55 and flexible coupling and coupling guard with the pump ,Common bed plate of fabricated mild steel channel or cast iron type. 180 LPM at 70 Mtr (15 HP). 274 Supplying & Installing cylindrical type air vessel, 250 mm dia 1.5M high of thickness 6.0 mm M.S. complete with air release valve, safety valve, pressure gauge etc.along with two coats of Red Oxide and two coat of post office red enamel paint as required. 275 Providing & fixing 100mm dia pressure Gauge on Pump DeliveryLine complete with shut off cock. 276 SITC of pressure switches for Main, Jockey, and standby pumps,including necessary wiring UPTO control panel and stop valve. 277 Sub Head - II - (Hydrants System) 278 Providing and fixing single headed hydrant valves with flanged inletISI marked with 63 mm female instantaneous outlet of gun metalcomplete with blank cap and chain conforming to IS : 5290 279 Providing . 63 mm dia 15 M long reinforced rubber hose pipeconforming to IS : 636-1962, Part –A & ISI marked with Gun Metalmale & female coupling wire wound with the pipe. 280 Providing & fixing (1.0 M x .45 M x 0.6 M ) OUTDOOR HOSECABINET suitable for accommodating hydrants made of not lessthan 16 swg. M. S. sheet having central opening glazed doorincluding necessary locking arrangement, painting (one coat primer& two coats of paint ) and housing 2 Nos. RRL hose pipe, 1 Nobranch pipe. 281 Providing and fixing Swinging Drum type hose reel ISI marked 30M(L) x 20 mm (dia) rubber lined pipe with shut off nozzle of 6 mm diaincluding the cost of 25 mm dia pipe connection from riser to hosereel , all sockets, nipples, elbows and 25 mm globe valve. 282 Providing and fixing ISI marked Three Way fire Brigade Inlet to wetRiser with non return valve complete in all respects 283 Providing, fixing, jointing and testing of Heavy Gauge (C class ) MSPipe ISI marked with accessories like tees, elbows, flanged joints,reducers, compressed asbestos gaskets, nuts and bolts includingfixing the pipe with suitable flat iron strip clamps /bracket, paintingetc. Complete as required for delivery/ suction manifold relating tothe pump including painting of two coats of Red Oxide and two coatof post office red enamel paint including all civil breakages andmaking good the same : 284 200mm dia 285 150 mm dia 286 80 mm dia 287 Sub Head - III - (Piping, Valves and Accessories) 288 MS (Medium duty B class) pipe with cleaning,wrapping and coatingof the pipe as per IS; 10221 in all kind of soil at 1.0 M depthincluding excavation as required. 289 150 mm dia 290 100 mm dia 291 80 mm dia 292 Providing & fixing Butterfly valve with Cast Iron Body, Cast Iron Discand Seat of Nitrile Rubber Bonded on Bakelite with hard back to PN1.6 rating with following sizes complete with bolts, washers andcompressed asbestos gasket as required 293 150 mm dia 294 100 mm dia 295 80 mm dia 296 Providing and fixing non return valve complete with bolts nuts washers and compressed asbestos gasket etc as required : 297 200 mm dia 298 150 mm dia 299 80 mm dia 300 Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5kg capacity. 301 Providing, fixing, testing & commissioning of sprinkler heads of thefollowing type : Pendant type with quartziod bulb, operating temperature at 68 deg Cas per specifications. 302 Providing & fixing 10 SWG chrome plated brass 100 mm diadecorative flanges / escutcheon plates to be fixed at junction ofSprinkler piping with the false ceiling. 303 Sub Head - III - (Piping, Valves and Accessories) 304 Sub Head - IV (Fire Electrical Control Panel) 305 Supplying and making end termination with heavy copper lugs (pin/ring type) duty crimped with crimping tool, PVC tape etc of followingsize 306 1.5 Sq.mm 307 10.0 Sq.mm 308 35.0 Sq.mm 309 Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. 100mm x 50mm x 1.6mm 310 BOUNDARY WALL G-SCHEDULE 311 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 312 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 313 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 314 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) 315 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-30 Grade Concrete. 316 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 317 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 318 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars 319 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing. 320 Random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of MoRT&H specification including all scaffolding material, labour, machinery but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand) 321 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 322 EARTH WORK 323 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 324 Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). In all type of soil Upto 3.0 m depth. 325 EXTERNAL DEVELOPMENT 326 Compacting original ground 327 Loosening upto a level of 500 mm below the subgrade level watered, graded and compacted in layers by vibratory roller 8-10 tonne to meet requirement of table 300-2 for subgrade construction as per MoRT&H specification clause 305.3.4. 328 Loosening and recompacting original ground below embankment including Loosening leveling and recompacting original ground supporting embankment to facilitate placement of of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling by vibratory roller 8-10 tonne so as to achieve minimum dry density as given in table 300-2 for embankment construction as per MoRT&H specification clause 305.3.4. 329 Providing, laying, spreading (with paver finisher only) and compacting wet mix macadam (WMM) base course comprising of graded stone aggregate and granular material conforming to MORT&H specifications (Table 400-II) in layers of equal compacted thickness each consolidated, including pre-mixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub-base/ base course and compacting with power vibratory-roller to achieve the desired density complete as per MoRT&H specification clause - 406 including all material, labour, machinery, lighting, guarding and maintenance of diversion. 330 CEMENT CONCRETE PAVEMENTS 331 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid manualy, compacting with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 332 Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. PCC M-30. 333 Providing and laying cast-in-situ cement concrete M-20 grade kerb stone channel top and bottom width 115 and 165 mm respectively, 250mm high laid with kerb laying machine, on 150 mm thick PCC M10 grade foundation (laid manually) as per design, including fixing at site as per clause 408 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. Using Concrete Mixer. 334 Providing and fixing of 60mm thick precast cement concrete interlocking paver block casted with rubber moulds in approved reflective colour and design having minimun compressive strength of 300 kg/ sq cm. The CC paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. 335 Flooring with Cobble stone of approx. Size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3 ( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respect as per direction of Engineer-in-charge. 336 Providing at site, lowering & laying in trenches, aligning & jointing of RCC pipes NP4 class (with s/s ends) IS: 458 - 2003 (amended up to date) marked and pipes from 300 mm and upto 1800 mm manufactured through vertical casting process at all depths with Rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of Rubber gaskets, lubricants) as per drawing, sectional hydro testing of the sewer pipe line (including cost and conveyance of water to site for testing) etc., complete as per specification and / or as directed by Engineer. Note : E/w to be measured and paid separately. 300 mm internal diameter. 337 Horticulture Work 338 Grassing with Doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. In rows 7.5 cm apart in either direction. 339 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 340 Ficus panda 341 Tecoma capensis ( Ratanjot) 342 Clerodendron inermii ( Choti Aari) 343 Tabernaemontana variegated ( Chandni) 344 Hamelia patens ( Firebush, Thal Kamal) 345 Hibiscus variegated ( Guddal) 346 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 300 mm min. height ground covers at site in 0.3 m dia holes, 0.3 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 347 Wedelia trilobata ( SunFlower Family) 348 Alternathera green (Parrot Leaf) 349 Iresine herbstii (Blood Leaf) 350 Ophiopogon Black ( Lily Turf, Mondograss) 351 Asparagus myerii (Fox Tail) 352 Lantana sellowiana 353 Rhoeo spathacea Compacta‘ ( Oyster, Boat Lily) 354 Golden duranta 355 Pennisetum setaceum (Fountain Grass)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
42.
Defence #10694376 Price Bid
Tender For Repair And Renovation Of 03 Nos Toilet Blocks ( Bd Unit ) At Nsg Manesar During 2023-24.; 1 Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, With In Nsg Campus At Designated Place. Nothing Extra Will Be Paid For Any Lead Or Lift With In Nsg Camo. : All Kind Of Soil 2 Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia 3 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 4 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 5 1:5:10 ( 1 Cement : 5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 10 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources ) 6 Making Plinth Protection 50 Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement: 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Finishing The Top Smooth. 7 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . 8 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : 9 Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 10 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete At All Level. 11 Thermo-Mechanically Treated Bars 12 Brick Work Withcommon Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In: 13 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 14 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 15 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 16 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. 17 Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 18 Brick Edging 7Cm Wide 11.4 Cm Deep To Plinth Protection With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 Including Grouting With Cement Mortar 1:4 ( 1 Cement : 4 Fine Sand ) . 19 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias, Window Jambs, Header, Horizontal, Verticaland Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing Of Edges To Give High Gloss Finish Etc. Complete At All Levels.Granite Stone Slab Of Colour Black, Cherry / Ruby Red 20 Granite Stone Slab Of Colour Black, Cherry / Ruby Red 21 Area Of Slab Upto 0.50 Sqm 22 Area Of Slab Over 0.50 Sqm 23 Extra For Providing Opening Of Required Size & Shape For Wash Basin / Kitchen Sink In Kitchenplatform, Vanity Counter And Similar Location In Marble / Granite / Stone Work, Including Necessaryholes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 24 Providing And Fixing Rubbed Stone Slab Table, Edges Rounded And Polished, 75 Cm High 50 Cm Deep And 18Mm Thick, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 6 Mm Nominal Size ) As Per Direction Of Engineer-In-Charge And Finished Smooth. 25 Granite Stone Of Approved Shade 26 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Of Size 300Mm X 600Mm Or More Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 27 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 28 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 29 Providing And Fixing Is : 12817 Marked Stainless Steel Butt Hinges With Stainless Steel Screws Etc. Complete :100X58x1.90 Mm 30 Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) , Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Including Dismantling Of Old Haps And Staple / Sliding Door Bolt If Required Complete : 31 300X16 Mm 32 250X16 Mm 33 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 34 300X10 Mm 35 200X10 Mm 36 Providing And Fixing Aluminium Handles, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 37 125 Mm 38 Providing And Fixing Fiber Glass Reinforced Plastic ( Frp ) Door Frames Of Cross-Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15 Mm To Receive Shutter Of 30 Mm Thickness. The Laminate Shall Be Moulded With Fire Resistant Grade Unsaturated Polyester Resin And Chopped Mat. Door Frame Laminate Shall Be 2Mm Thick And Shall Be Filled With Suitable Wooden Block In All The Three Legs. The Frame Shall Be Covered With Fiber Glass From All Sides. M.S. Stay Shall Be Provided At The Bottom To Steady The Frame. 39 Providing And Fixing To Existing Door Frames. 40 30 Mm Thick Fiberglass Reinforced Plastic ( F.R.P. ) Flush Door Shutter In Different Plain And Wood Finish Made With Fire Retardant Grade Unsaturated Polyester Resin, Moulded To 3 Mm Thick Frp Laminate All Around, With Suitable Wooden Blocks Inside At Required Places For Fixing Of Fittings And Polyurethane Foam ( Puf ) / Polystyrene Foam To Be Used As Filler Material Throughout The Hollow Panel, Casted Monolithically With Testing Parameters Of F.R.P. Laminate Conforming To Table - 3 Of Is: 14856, Complete As Per Direction Of Engineer-In-Charge. 41 Providing And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily. 42 Glazed Vitrified Tiles Matt / Antiskid Finish Of Size 43 Size Of Tile 600 X 600 Mm 44 Providing And Laying Polished Granite Stone Flooring / Door Sillin Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. 45 Polished Granite Stone Slab Colour Of Jetblack, Cherry / Ruby Red Or Equivalent 46 Providing And Fixing On Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Sewer Pipes Conforming To Is : 13592 Type B, Including Jointing With Adhesive. 47 Coupler A ) 110 Mm 48 Single Tee With Door A ) 110X110x110 Mm 49 Single Tee Without Door A ) 110X110x110 Mm 50 Bend 87.5° A ) 110 Mm Bend 51 12 Mm Cement Plaster Of Mix : ( Including Height Up To 10 Meters ) 52 1:6 ( 1 Cement: 6 Coarse Sand ) 53 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : ( Including Height Up To 10 Meters ) 54 1:6 ( 1 Cement: 6 Coarse Sand ) 55 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicon Additive Of Required Shade : ( Including Height Up To 10 Meters ) 56 New Work ( Two Or More Coat Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) 57 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : ( Including Height Up To 10 Meters ) 58 Two Or More Coats On New Work 59 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. ( Including Height Up To 10 Meters ) 60 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : ( Including Height Up To 10 Meters ) 61 One Or More Coats On Old Work 62 Finishing Walls With Primium Acrylic Smooth Exterior Paint With Silicon Additives Of Required Shade : ( Including Height Up To 10 Meters ) 63 Old Work ( One Or More Coat Applied @ 0.83 Ltr / 10 Sqm ) . 64 Cleaning Of Chocked Sewer Line By Diesel Running Vehicle Mounting Hydraulic Operated High Pressure Suction Cum Jetting Sewer Cleaning Machine Fitted With Pump Having 4000 Litres Suction Capacity And 6000 Litres Water Jetting Tank Capacity Including Skilled Operator, Supervising Engineer Etc. For Cleaning And Partial Desilting Of Manholes And Dechocking Of Sewer Lines. Dechocking And Flushing Of Sewer Line From One Manhole To Another By High Pressure Jetting System Of 2200 Psi For Sewer Line From 150Mm Dia Upto 300Mm 65 Providing & Fixing White Vitreous China Water Closet Squatting Pan ( Indian Type ) Along With S Or P Trap Including Dismantling Of Old Wc Seat And S Or P Trap At Site Complete With All Operations Including All Necessary Materials, Labour And Disposal Of Dismantled Material I / C Malba, All Complete As Per The Direction Of Engineer-In Charge. 66 Orissa Pattern W.C Pan Of Size 580X440 Mm 67 Dismantling W.C. Pan Of All Sizes Including Disposal Of Dismantled Materials I / C Malba All Complete As Per Directions Of Engineer-InCharge 68 Dismantling 15 To 40 Mm Dia G.I. Pipe Including Stacking Of Dismantled Pipes ( Within 50 Metres Lead ) As Per Direction Of Engineerin- Charge. ( A ) Internal Work- Exposed On Wall 69 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. 70 Nominal Concrete 1:3:6 Or Richer Mix ( I / C Equivalent Design Mix ) 71 Taking Out / Dismantling Doors, Windows And Clerestory Window Shutters ( Steel Or Wood ) With Or Without Chowkhats Includingstacking Within 50 Metres Lead : 72 Of Area 3 Sq. Metres And Below 73 Dismantling Tile Work In Floors And Roofslaid In Cement Mortar Or Top Cement Mortar Layer Of Coba Treatment Including Stacking Material Within 50 Metres Lead. 74 For Thickness Of Tiles 10 Mm To 25 Mm 75 Dismantling Of Flushing Cistern Of All Types ( C.I. / Pvc / Vitrious China ) Including Stacking Of Useful Materials Near The Site And Disposal Of Unserviceable Materials Within 50 Metres Lead. 76 Dismantling Old Plaster Or Skirting / Wall Tile Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 77 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors, Dismantling Of Old European Type W.C. Pan Wherever Required : 78 W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 79 Providing And Fixing P.V.C. Low Level Flushing Cistern With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete. 80 10 Litre Capacity - White 81 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. 82 Semi Rigid Pipe 83 32 Mm Dia 84 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I / C Making Good The Walls Etc. Concealed Pipe, Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall : 20 Mm Dia Nominal Bore 85 Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. 86 20 Mm Dia Nominal Bore 87 25 Mm Dia Nominal Bore 88 Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : 89 25 To 40 Mm Nominal Bore 90 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 91 25 Mm Nominal Bore 92 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 93 45 Cm Length 94 15 Mm Nominal Bore 95 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 96 150 Mm Diameter 97 Painting G.I. Pipes And Fittings With Two Coats Of Anti-Corrosive Bitumastic Paint Of Approved Quality : 98 20 Mm Diameter Pipe 99 25 Mm Diameter Pipe 100 Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) : 101 20 Mm Nominal Bore 102 25 Mm Nominal Bore 103 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 104 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 105 15 Mm Nominal Bore 106 Providing And Fixing C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931. A ) 15 Mm Nominal Bore 107 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 A ) 15 Mm Nominal Bore 108 15Mm Nominal Bore 109 Providing And Fixing C.P. Brass Extension Nipple ( Size 15Mmx50mm ) Of Approved Make And Quality As Per Direction Of Engineer-In-Charge. 110 Providing And Fixing Ptmt Ball Cock Of Approved Quality, Colour And Make Complete With Epoxy Coated Aluminium Rod With L.P. / H.P.H.D. Plastic Ball. 111 20 Mm Nominal Bore, 120 Mm Long, Weighing Not Less Than 198 Gms 112 Providing And Fixing Gi / Ptmt Extension Nipple For Water Tank Pipe, Fittings Of Approved Quality And Colour. 20 Mm Nominal Bore, Weighing Not Less Than 40 Gms 113 Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 114 100X100 Mm Size P Type 115 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 116 Providing And Laying Non-Pressure Np2 Class ( Light Duty ) R.C.C. Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints 117 300 Mm Dia. R.C.C. Pipe 118 Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) With R.C.C. Top Slab With 1:1.5:3 Mix ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : 119 Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame ( Light Duty ) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15 Kg ) : 120 With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 121 Extra For Depth For Manholes :Size 90X80 Cm With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 122 Providing And Fixing In Position Pre-Cast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Qualityl D- 2.5Rectangular Shape 600X450 Mm Internal Dimensions 123 Making Connection Of Drain Or Sewer Line With Existing Manhole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Cement Plastered On Both Sides With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) , Finished With A Floating Coat Of Neat Cement And Making Necessary Channels For The Drain Etc. Complete : 124 For Pipes 100 To 450 Mm Diameter 125 Raising Manhole Cover And Frame Slab To Required Level Including Dismantling Existing Slab And Making Good The Damage As Required ( Raising Depth Of Manhole To Be Paid Separately ) :Rectangular Manhole 90X80 Cm With Rectangular Cover 600 X 450 Mm Of Grade Ld - 2.5 126 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fastenersto Be Paid For Separately ) : 127 For Fixed Portion 128 Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 129 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) 130 Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 131 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : 132 With Float Glass Panes Of 5 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) 133 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : ( A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. ( B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 134 Providing And Applying White Cement Based Putty Of Average Thickness 0.5 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 135 Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm / 230Mm / 300 Mm Thick Aac Blocks In Super Structure Above Plinth Level Up To Floor V Level With Filling Joint With Cement Mortar ( 1 Cement :4 Coarse Sand ) All Complete As Per Direction Of Engineer-In-Charge. 136 Dismantling C.I. Pipes Including Excavation And Refilling Trenches After Taking Out The Pipes, Manually / By Mechanicalincluding Stacking Of Pipes & Lead At Site Within 50 Metre Lead As Per Direction Of Engineer-In-Charge: 137 Up To 150 Mm Diameter 138 Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm Withspreaders ( C.P. Brass ) With Waste Fitting As Per Is : 2556, With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittings And Cutting And Making Good The Walls Floors Wherever Required : 139 Single Half Stall Urinal 140 Providing And Fixing Cp Grating Of Approved Quality Circular Type, 110 Mm Dia, With Or Without25 Mm Waste Hole 141 Providing And Fixing Table Top Wash Basin [ Cera Calburt Or Equivalent ] Of Size 550 Mm X 400 Mm Snow White Table Top Basin With 15 Mm C.P. Brass Pillar Taps [ Equivalant To Cat No 9302 ( Prayag Make ) , Cera F1015101 Steel Pillar Cock, Silver, Steel Finish Or Equivalent ] , 32 Mm C.P. Brass Waste Of As Per Approved Make Of Selection Including Fittings And Waste Pipe Etc. And Fixing On Wash Basin Counter By Tile Adhesive Of Approved Make. 142 Providing And Laying Unplasticised Rigid Pvc Sewer Pipe Wih Min. Pressure 6 Kg / Sqcm Conforming To Is : 13592 , Type B Including Jointing With Adhesive ( I ) Plain Socketed Pipes. ( Including All Heights Up To 10 Meter ) 143 110 Mm Diameter 144 Providing And Fixing On Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Sewer Pipes Conforming To Is : 13592 Type B, Including Jointing With Adhesive. 145 110 Mm P Trap 146 Providing And Fixing 1200 Mm X 750 Mmmirror With Plastic Moulded Frame Havingglass Thickness Not Less Then 5Mm Thick Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 147 Providing And Fixing C.P Brass Health Faucet As Per Approved Design And Make And All Fitting Etc Complete, Including Cost Of Cutting And Making Good The Walls And Floors As Per Direction Of Engineering In Charge. 148 Providing And Fixing C.P. Brass Pressmatic Valve Hindware Or Equivalent Approved Quality Conforming To Is Standards 149 15Mm Nominal Bore 150 Excavating / Demolishing Of Malba / Foam Concrete / Lean Mix And Refillingin Sunken Portion Of Toilet As Per Direction Of Engineering-In-Charge 151 Providing And Fixing 600 Mm Long Cp Brass Towel Rail Completefixed To Wooden Cleats Withscrews Of Approved Quality As Per Direction Of Engineer In Charge. 152 Providing And Fixing Gi Pipe Clamp For Pvc Rain Pipes Of Diameter : A ) 110 Mm 153 Providing And Fixingss Cloth Hanger With 06 Hookcompletefixed Withscrews Of Approved Quality As Per Direction Of Engineer In Charge. 154 Credit For Dismantled Material Received From Site Of Work Which Will Be Handed Over To Contractor As Per Direction Of Engineer-In-Charge.Dismantled Old Wood 155 Credit For Dismantled Material Received From Site Of Work Which Will Be Handed Over To Contractor As Per Direction Of Engineer-In-Charge.Dismantled Old Steel 156 Credit For Dismantled Material Received From Site Of Work Which Will Be Handed Over To Contractor As Per Direction Of Engineer-In-Charge.Dismantled Old Pvc 157 Electrical 158 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 159 Group B 160 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required. 161 Group B 162 Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 163 Group B 164 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 165 Wiring For Light / Power Plug With 4X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit Alongwith 2 Nos 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 166 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 167 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 168 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 169 3 X4 Sq.Mm 170 6 X4 Sq.Mm 171 3 X 1.5 Sq.Mm 172 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 173 20 Mm 174 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 175 5 / 6 Amp Switch 176 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 177 1 Or 2 Module ( 75Mmx75mm ) 178 3 Module ( 100Mmx75mm ) 179 12 Module ( 200Mmx150mm ) 180 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, C Curve Including Connections, Painting Etc. As Required. ( For Geyser / Ac ) 181 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 182 Providing And Fixing A Metallic Louvred Shutter Suitable For Following Sizes Exhaust Fan, The Louvres Should Be Able To Open When The Fan Is On And Close When The Fan Is Turned Off, On The Existing Opening On The Wall, Etc., As Required. 183 300 Mm 184 Providing And Fixing 3 Mm Thick Pvc / Phenolic Laminatedround Sheet Cover With A Minimum Of 170 Mm Dia On The Existing Fan Box With Two Screws, Etc., As Required. 185 Providing And Fixing 3 Mm Thick Pvc / Phenolic Laminatedround Sheet Cover On The Existing Junction Boxwith Two Screws, Etc., As Required. 186 Supplying And Fixingprcd Plug Top, 16 A 30 Ma Rating Including Connection Etc. As Required. 187 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 188 Supplying And Installation Of 300 Mm Sweep, 1400 Rpm Heavy-Duty, Single Phase, Metallic Exhaust Fan Conforming To Is:2312 -1967In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. ( Havellsturbo Force Heavy Duty Exhaust Fan Or With Similar Specifications C&G / Orient / Usha / Almonard ) 189 300 Mm Sweep 190 Cutting Holes Of Required Size In Brick Masonry Wall For Fixing Of Exhaust Fan Including Providing And Fixing 300 Mm Dia Pvc Pipe And Making Good The Same Etc. Complete As Per Direction Of Engineer-In-Charge. 191 Supply, Installation, Testing And Commissioning Of Surface Mountedled Downlighter Luminaire Inmetallic Housing, With A Minimum System Lumen Output Of 1500 Lumen Andwith A Minimum System Luminous Efficacy Of 100 Lm / W, Average Led Life L70b50: 50000 Hours, Suitable For Operation On 140-270V, 1F, 50Hz Ac Supply System, Complete With All Accessories, Diffuser And Electronic Driver, Directly On Ceiling, Including Connections And Earthing Etc. As Required. 192 Supply, Installation, Testing, And Commissioning Of Integrated Led Batten Luminaire, 600 Mm ( Nominal Size ) With A Minimum System Lumen Output Of 1000 Lumen Andwith A Minimum System Luminous Efficacy Of 100 Lm / W, Made Of Aluminium Housing Having A Colour Temperature5500k - 6500 K, Average Life L70b50: 50000 Hours, Suitable For Operation On 140-270V, 1F, 50Hz Ac Supply System, Complete With All Accessories, Electronic Driver, Diffuser, Directly On The Ceiling / Wall, Including Connections, Earthing, Etc. As Required. 193 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing Andcommissioning Etc. As Required. 194 Single Pole 195 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 196 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) ( Note : Db Should Be Suitable For Rccb / Rcbo As Incomer. ) 197 12 Way , Double Door 198 Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Following Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface / Recess, Complete With Testing And Commissioning Etc. As Required 199 For 10 / 12 Way, Double Door Spn Mcbdb 200 Supplying And Fixing Following Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required 201 40 A Double Pole 202 Dismantling Of The Existing Switch Accessories Like Switches, Sockets, And Mcbs, Etc., As Required. 203 Dismantling Of The Existing Ceiling Rose, Holder, And Wall Bracket And Depositing The Same With The Listing Of Materials In The Store. 204 Dismantling Of Existing Fluorescent Fitting From Ceiling / Wall Including Making Good The Damage To Match The Adjacent Surface, Etc., As Required. 205 Dismantling Of The Existing Ceiling Fan / Exhaust Fan Of Any Size Installed In The Building And Depositing It In The Mmc Store. 206 Dismantling Of The Existing Recessed Spn Mcb Distribution Board Of Any Size Along With Mcbs And Other Accessories, Including Making Good The Damage To Match The Adjacent Surface, Etc., As Required. 207 Dismantling Of The Existing Recessed Switch Board Of Light Points / Power Points, Power / Light Plug Points / Socket Outlet Metal Boxes Of Any Size, Along With Phenolic Laminated Sheet, Switches, Sockets, Etc., Making Good The Damage To Match The Adjacent Surface, Etc., As Required. 208 Dismantling Wires From The Following Sizes, Existing Circuit / Submain / Power Wiring Conduits, Complete As Required. The Length Of The Conduit From Which The Wires Are Removed Will Be Measured For Payment Purposes, Irrespective Of The Number Of Wires In It.Above 25 Mm Conduits. 209 Dismantling Wires From The Following Sizes, Existing Circuit / Submain / Power Wiring Conduits, Complete As Required. The Length Of The Conduit From Which The Wires Are Removed Will Be Measured For Payment Purposes, Irrespective Of The Number Of Wires In It.Up To 25 Mm Conduit. 210 Less Credit For The Unserviciable Items Dismantled Items During Execution Of The Work. 211 Assorted Mcb Tp And Tp&N & Other Switchgear 212 Assorted Piano Type Switches 213 Assorted Piano Type Sockets 214 Assorted Brass Batten / Angle Holder / Brass Bracket 215 Assorted Exhaust Fan 300 / 380 / 450 216 Less Credit For The Dismantled Copper Wirewires From Light Points / Circuit / Submain / Power Circuit Wiring, . 217 Less Credit For The Dismantled Aluminium Wirewires From Light Points / Circuit / Submain / Power Circuit Wiring, . 218 Assorted Metal Switch Box. 219 Assorted Mcb Db Spn With Out Mcbs 220 Assorted Mcb Sp 221 Assorted Mcb Dp 222 Add 1.0633 Multiplying Factor For Gst On Dsr
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
43.
Housing Urban and Rular Development #10692680 Price Bid
Earth Work Excavation For Foundation In Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales Murram, Gravel, Stoney Earth And Earth Mixed With Small Size Boulders Ss.20B And Sand, Silt Or Other Loose Soil, Wet Sand, Or Silt Not Under Water, Light Black Cotton Soil, Sandy Loam Ordinary Soil And To Full Depth As May Be Directed Except In Hardrockrequiring Blasting Inclusive Of Shoring Shuttering And Baling Out Water And Cleaning And Levelling The Site Etc., Complete 10 Cum 2 Column 3 Plinth Beam 4 Supplying And Filling In Foundation Andbasement With Filling Crushed Stone Sand In Layers Of Not More Than 15Cm.Thick Well Rammed Watered And Compactedetc., Complete Complying With Standard Specification. 5 Cement Concrete 1:4:8 ( One Cement, Five Sand And Ten Hard Broken Stone Jelly ) Using 40 Mm Gauge Hard Broken Granite Stone Jelly For Foundationincluding Dewatering Wherever Necessary And Laid In Layers Of Not More Than 15 Cm Thick Well Rammed, Consolidated And Curing Etc. Complete Complying With Standard Specification 6 Providing And Laying In Position, Standardised Concrete Mix M-20 Grade In Accordance With Is:456-2000, Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cement Content Of 325 Kg / M? And Maximum Water Cement Ratio Of 0.55, Including Admixture ( Plasticiser / Super Plasticiser ) In Recommended Proportions As Per Is:9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About ( 5 Cu.M. ) 7730 Kg. Of 20Mm Machine Crushed Stone Jelly And With About ( 3.3 Cu.M. ) 5156 Kg. Of 10-12Mm Machine Crushed Stone Jelly And With About ( 4.79 Cu.M. ) 7670 Kg. Of Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators Etc Completed 7 Foundation & Basement 8 Centering For Soffits Of Rcc Slabs Of Plane Surface Like Lintels, Beams , Etc., Including Strutting 3M High Using Mild Steel Sheets Of Size 90Cm X60cm X And B.G 10 Stiffened With M.S Angles Of Size 25Mm X 25Mm X 3Mm Laid Over Silver Oak ( C.W ) Joists Of Size 10Cm X 6.5Cm ( Spaced At About 90Cm C / C ) And Supported Dy Casurina Props Of 10Cm To 13Cm Dia ( Spaced Of 75Cm C / C ) Complying With Standard Specification And Directed 9 Column 10 Plinth Beam 11 Suppling And Fabricating And Placing In Position Ms ( Or ) R.T.S. Bar For Reinforcement To All Rcc Works As Per The Design Given Including Cost Ofsteel And Binding Wire Also In All Floors. 12 Brick Work In Cm 1:5 Mix Using Second Class Ground Moulded Chamber Burnt Bricks 9 X 4 3 / 8 X 2 ¾ Sizeincluding Cost And Conveyance Of Materials And Labour Charges Etc., Complete As Per Standard Specification. ( Item No. 2B ) 13 Foundation & Basement 14 Superstructure From G.F 15 Plastering With Cm 1:5 Mix Using 12Mm Thick Including Cost And Conveyance Of Materials And Labour Charges Etc., Complete As Per Standard Specification 16 Painting Two Coats Of Newly Plastered Wall Surface With Approved Cement Paint Over Cement Plastered Wall Surface, Ceiling Andincluding Preparing The Surface, Clean Removal Of Dirt And Including Necessary Plaster Of Paris Putty Wherever Required And Cost Of Painting Materials, Brushes, Preparation Of Surfaces And Scaffolding Charges Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officer 17 Supply Delivery And Filling Of Carted Earth In Layer Of Not More Than 15Cm Thick Including Watering With All Layers And Consolidation Complying With Standard Specifications Inlcuding Cost And Conveyance Of All Materials And Labour Charges Etc., Complete 18 Providing And Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam ( Wmm ) Specification Including Premixing The Material With Water At Omc In Mechanical Mix Plant Carriage To Mixed Material By Tipper To Site Laying In Uniform Layers With Paver In Sub Base / Base Course On Well Prepared Surface And Compacting With Vibratory Roller To Achive The Desired Density Complete As Per Clasue 406 Of Morth Specifications. 19 Plaincement Concrete 1:2:4 Mix ( One Cement, Two Fine Aggregate And Four Course Aggregate ) Using 20Mm Iss Hbg Metal Including All Cost Conveyance Of Materials And Labour Charges Including Vibrating Charges Etc. Complete As Per Standard Specification. 20 Fabrication Supply And Fixing In Position Weld Mesh Inclusive And Cost Of Red Oxide Prime Etc.., Complete As Per Standard Specification. 21 Supplying, Fabricating, Erecting Structural Steel Work For Roofing Welded Or Bolted Type Using Ms Channels, Angles, Plates And Round Bars Etc. Conforming To Is Specification Including Primer Coating And Enamal Painting As Per Design Given By The Departmental Officers Etc, Complete As Per Standard Specification 22 Fabricating Supplying And Fixing Of Pre Painted Galvanium Iron Sheets With The Following Specification. The Materials Should Be Of Ppgi Tile Profile With A Red Colour Or Any Other Approved Design 0.47Mm Thick 24 Guage Having Width 1050 Mm. The Sheet Should Be G.I.Base Pre Painted Hot Dipped Galvanized Iron Sheet And To Be Fixed With Shelf Tapping Screws, Plastic Washer.The Washer And Screws To Be Fixed By Using Minute Power Machine Drilled With Out Damaging The Sheets Paint Coating To Be Regular Modified Polyster Coat With Zinc Coating Of Z 120 Gsm Paint Thickness The Finish Should Be Terra Cotta Finish Like Malabar Mangalore Tiles Finish Optional Matt Finish. The Sheet To Be Fixed With Making Suitable Corrugated, Cutting The Sheet In To The Required Ssize And Making Ornamental Designs As Per The Site Condition And As Directed By The Departmental Officers. 23 Providing & Fixing Pvc Rain Water Downfall Pipe Of The Following Dia With Necessary T.W.Clamps Plugs, Shoes, Bemds, Other Clamps, Screws Nails Etc., Complete Complying With Standard Specification. The Rate Is Inclusive Of Cost Of Removable Iron Gratings Of Appropriate Size. The Size Of Teak Wood Plugs Used Is 150X25mm In Front & 200X75mm In Rear ( Wall Side ) With A Depth Of 110Mm. The Pipe Is To Be Fixed By Means Of U Clamps At The Centre Of Pipes To Be Fixed.110Mm Dia Pvc Pipe [ 4 Kg / Sqcm ] 24 Special Ceiling Plastering For Rcc Slabs And Beams With Cement Mortar 1:3 Mix 10Mm Thick Including Cost And Conveyance Of All Materials To Site, Loading And Unloading Charges And Labour Charges For Mixing, Laying And Curing Etc. Complete . Complying With Std. Specifications 25 Wiring With 2 X 1.5 Sq.Mm. ( 22 / 0.3 ) Pvc Insulated Single Core Unsheathed Copper Conductor Cable Of 1100V Grade In Suitable Heavy Gauge Ms Conduit Pipe On Wall And Ceiling With Ms Accessories With Ms Switch Box And 5A Ft Switch With Painting Of Suitable Colour Continuous Earth Wire Connection Of 14 Swg Tc Wire For Light Point / Fan Point ( For Electronic Regulator ) ( Sd-22 ) 26 Wiring With 2 X 4 Sq.Mm. ( 56 / 0.3Mm ) Pvc Insulated Single Core Unsheathed Copper Cable Conductor Cable Of 1100V Grade In Suitable Heavy Gauge Ms Conduit Pipe On Wall And Ceiling With Ms Accessories With 150Mm X 100Mm X 75Mm Ms Switch Box For 15A 3 Pin Non Interlocking Cs Plug With Painting Of Suitable Colour With Continuous Earth Wire Connection By 14 Swg Tc Wire For Open Power Plug Point ( Sd-39 ) 27 Supply And Run Of 2 Of 1.5 Sq.Mm. ( 22 / 0.3 ) Pvc Insulated Single Core Unsheathed Copper Conductor Of 1100V Grade In Suitable Pvc Rigid Pipe On Wall And Ceiling With Continuous Earth Wire Connection 14 Swg Tc Wire With Painting Of Suitable Colour ( Sd-54 ) 28 Supply And Fixing Of Single Box Type 440W Fluorescent Fitting Complete With Copper Choke And Condensor With Conduit Pipe Suspension From The Ceiling With Pvc Unsheathed Copper Leads From Terminals To The Fitting With Tube ( Sd -88 ) 29 Supply And Fixing Of 25Mm G.I. Service Pipe With Bend Including Cost And Conveyance Etc., Complete., As Per Standard Specification As Directed By The Departmental Officers 30 Painting With Two Coats Of Approved Colour Painting Including Cost And Conveyance Of Materials And Labour Charges Etc. Complete As Per Standard Specification For ( New Iron Surface ) 31 Supply And Fixing Of 1200Mm ( 48 ) Sweep Ac Ceiling Fan Complete With Stepped Electronic 300W Regulator With 1Metre Down Rod With Fan Clamp With Side Plates And Cross Arm Of Size 450Mm ( 18 ) ( Sd - 106 ) 32 Hydraulic Plastic Bailing Machine With Mechanical Vertical Clamping Force - Ms Body - Chamber Size 700 X 500 X 1400 ( Mm ) - Bail Size 700 X 500 X 650 ( Mm ) With Bail Weight Of 50-60Kg, 15-20 Cycle Time Per Bale In Minutes, Single Cylinder 700 X 500 ( Mm ) - Hydraulic System Gear Cum Plunger Pump System And Day Light Gap Between Bottom Plate And Pressing Plate 1400 Mm Motor Power 7.5 Hp, 2Nos Ties Of Rope, Single Door, Body Plate 8 Mmm Thickness, Clamping Plate Thickness 30 Mm And 3 Phase - Electrical Control System - Manual Bale Eject Swing Plate With Screw System, Hand Lever Operated And Drainage System For The Residual And Fluid / Liquid While Rushing / Pressing The Material Provisions, Overall Weight Of The Machine In 1000 Kg Overall Dimensions Of The Machine In Mm X Mm X Mm ( Length X Width X Height ) 700X500x650 Mmadditional Parameters: The Machine Should Be Painted And Power Coated To Avoid Rust, Packaging Should Be Into Crate Using Timber Bracing, Electrical Safety System Shall Confirm To Is 302, Instruction Mannual, Service Details, Maintanance Manual L To Be Provided With The Machine, Installation And Demonstration To Be Completed By The Seller Before Acceptance Of Item, Certificates: Manufacturer Of The Machine Shal Be Holdingiso 9001:2008 / 2015 Certification, Details Of Iso Certification Picl / Qms / 0518 / 2059 31.05.2018, Test Certificate From Govt / Nabl / Ilac Approved Lab Regarding Various Performance Parameters Indicated As Well As Electrical Saftey Systems As Per Is 302, Test Report No Gm / 2019 / 78 Test Report Date 25 / 11 / 2019, Name And Address Of Lab Gujarat Metal & Equipment Testing Lab- Rajkot Copies Of All Certifications And Test Reports To Be Provided To Buyer On Demand At Time Of Supplies . Including Labour Cost. ( Warranty 1 Year ) 33 Supply, Fixing And Commissioning Of Plastic Shredder Machine ( Grinding Of All 7 Category Of Plastic Waste ) Wit 6 Blades Size Of 46 X 13Cm , With Shredding Capacity Of 200 To 250 Kg Per Hour Having Motor Capaity Of 15 To 22.5 Kw With Cast Iron Body Including Conveance And All Labour Harges Etc, Complete With Standard Specification. 34 Supply And Delivery Of Sorting Table Size 8.00 X 1.50M Including Conveance And All Labour Harges Etc, Complete With Standard Specification. 35 Supply And Delivery Of Electronic Weighing Scale 2000Kg Capacity Including Conveance And All Labour Harges Etc, Complete With Standard Specification. 36 Supply And Delivery Of Manual Fork Lift Of Capacity 100Kg Capacity Including All Labour Harges Etc, Complete With Standard Specification. 37 Solid Pvc Door Shutters Using 19 Gauge 19Mm Ms Square Tubes For Styles And Outer Frames. 15Mm Ms Square Tubes For Top, Lock And Bottom Rails. The Steel Tubes Shall Be Covered With 5Mm Thick Solid Pvc Sheets. Shutter Using 5Mm Thick Solid Pvc Sheets For Panelling Shall Rigidly Fixed In Position Including Necessary Furniture And Fittings. The Over All Size Of Styles Shall Be 50Mm X 30Mm. The Over All Size Of Top Rail, Lock Rail And Bottom Rail Shall Be 75Mm X 30Mm. The Over All Size Of Frames Shall Be 50Mm X 45Mm With Suitable Rabate For Housing The Shutter 38 Supplying And Erecting Pull And Push Type Rolling Shutter With I.S.I. Make Of Approved Size And Section Using 18 Gauge G.I.Sheet With Manually Operated Type. The Shutter Shall Be Painted With One Coat Of Red Oxide Primer And The Rate Is Inclusive Of Hood Covers, Transportation Charges Etc, Complete As Per Standard Specification. 39 Supply And Delivery Fabrication Of Ms Doors And Windows With Outer Frame And Shutter Frame In Ms Angle Of Size 40Mm X 40Mm X 6 Mm With Ms Flat 25Mm X 25Mm X 6Mm And Ms Sheet Of 18 Gauge Including Ventilating Arrangements Using 20Mm Square Ms Rods With Locking Arrangements Including Two Coats Of Approved Enamel Paint Over Coat Of Red Oxide Including Cost Of Angles, Plates, Sheets, Fabrication Charges, Cost Of Hold Fast And Transportation Charges Etc., Complete. ( Twad Sor Pg.No87 ) 40 Fully Panelled Single Leaf Door 0.90 X 2.00Mt 41 Fully Panelled Double Leaf Window 1.20 X 0.90Mt 42 Ventilator 0.45 X 0.60 43 Supplying And Fixing In Position Indian Water Closet Of Size 580 X 440Mm, White Glazed Earthen Ware Of Approved Quality With P Trap Or S Trap Confirming To Is:2556 -Part Xii With Sand Cushion And Forming Flooring Alround The Closet Using 40Mm Broken Brick Jelly In Lime Concrete1:2:5 ( One Part Of Lime, Two Parts Of Sand And Five Parts Of Brick Jelly ) 100Mm Thick And Finishing The Top To Required Slope And Including Giving Necessary Connection To Cast Iron Soil Pipes / Pvc Pipes By Dismandling Brick Masonry, Reinforced Cement Concrete Roof / Floor Slab And Making Good The Disturbed Portion To Original Condition Without Leakage Etc., Complete Complying With Standard Specifications And As Directed By The Departmental Officers. 44 Providing Granolithic Floor Finish Of 25Mm Thickness With Plain Cement Concrete 1:2:4 ( One Cement, Two Crushed Sand ( M-Sand ) And Four Aggregate ) Using 10 To 12Mm Gauge Hard Broken Stone Jelly Including Laying, Finishing And The Top Rubbed Smooth With Power Trawl, Thread Lining, Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. ( The Rate Is Inclusive Of Necessary Planking For Panellingwherever Necessary And As Directed By The Departmental Officers ) 45 Supply And Fixing Of Tneb Board Suitable For 3 Phases 63A Service Connection Made Up Of Suitable Angle Iron Frame Work Of Size 2 Feet X 1 1 / 2 Feet Using Angle Iron Of Size 1 1 / 2 X 1 1 / 2 X 1 / 4 Rigidly Fixed On Wall Covered With Hylem Sheet Of Size 2 Feet X 1 / 2 Feet Of 6Mm Thickness With Necessary Bolts And Nuts Supports And Supply And Fixing Of 3 Nos 63A Fuse Units ( 500V ) 1 No. Neutral Link, Copper Earth Flat Of Size 1 X 1 / 4 With Inter Connection Of Eb Meter To Fuse Units By 7 / 16 Pvc Insulated Copper Wire With Earth Connection Complete.Sd 129 46 Supplying And Fixing In Position Best Quality P.V.C Soil / Waste Pipes ( 6Ksc ) Of Various Sizes Having Isi Mark And Providing Leakproof Joints Including Fixing To The Wall With P.V.C / M.S Clamps Etc., And Making Connection To All Sanitaryfittings, Dismandling Masonry / R.C.C. Works Wherever Necessary And Making Good The Dismandled Portion To The Original Condition, Complying With Standard Specifications. 47 110Mm Dia Pvc 6Ksc Pipe 48 Supplying Laying And Jointing G.I. Pipes Of Approved Quality And Best Varity Of B Class Pipe Of 20Mm Dia In Size Including Fixing G.I Specials But Excludingcost Of Such Specials Cutting Threading Of Pipes Andfixing To Wall With Necessary Teak Wood Plugs, Clamps And Screws Masking Holes On The Wall Or Drilling Holesin Roof And Making Good The Dismandled Portions To Original Conditions With Necessary Brick Work And Concrete And Plastering Where Ever Necessary With Necessary Scafolding Charges. The Pipes Are To Be Painted With Two Coats Of Good Variety And Best Approved Quality Of Synthetic Enamel Paint Over A Priming Coat Of Red-Oxide Primer Etc., Complete. 49 Supplying And Fixing In Position First Quality And Approved Variety Of Gun Metal Gate Valve ( Heavy Type ) With I.S.I.Mark Of 25Mm Dia In Size Including Cost Of Shellac , Thread Etc, .Including Labour For Cutting And Threading Of G.I.Pipes Etc., Complete Complying With Standard Specifications For Both Internal And External Water Supply Arrangements. 50 Suppling And Fixing In Position15mm.Diameter Brass Screw Down Tap ( Heavy Duty ) Of Approved Make Conforming To I.S.Specifications And Quality Including Cost Of Shellac , Thread Etc.Complying With Standard Specifications And Including Cutting And Threading Wherever Necessary. 51 Supply And Fixing Of Following Plumbing G.I.Materials 52 20Mm Dia G.I Coupling 53 20Mm Dia G.I Tee 54 20Mm Dia G.I Elbow 55 20Mm Dia G.I Union 56 20Mm X 15Mm Dia G.I Reducer Elbow 57 Supplying And Fixing In Position C.I.Manhole Covers ( Light Or Heavy Duty ) Of 600 X 600Mm In Size Of Best Approved Quality And As Per Standard Specifications Etc., Complete. 58 Supplying And Fixing P.V.C. Ventilating Shaft Of110mm Dia And 3M Height Of Best Approved Quality And As Per Standard Specifications. 59 Gst. 18% ( Cgst-9%, Sgst-9% )
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
44.
Public Administrative Department #10653635 Price Bid
Civil Work - Repair Of Mcd Flat Nob-4 By Plastering, Painting, Wooden Work, M.S Steel Work, , Door And Window Repairs, Aluminium Work, Plumbing Work, Distempering And Water Proofing Treatment Etc.In R-Block In Ward No.-173 ( Greater Kailash ) / South Zone-Repair Of Mcd Flat No B-4 By Plastering, Painting, Wooden Work, M.S Steel Work, , Door And Window Repairs, Aluminium Work, Plumbing Work, Distempering And Water Proofing Treatment Etc. In R-Block In Ward No.-173 ( Greater Kailash ) / South Zone , Dsr 2018 And Approved Items; 1 Repair Of Mcd Flat No B-4 By Plastering, Painting, Wooden Work, M.S Steel Work, , Door And Window Repairs, Aluminium Work, Plumbing Work, Distempering And Water Proofing Treatment Etc. In R-Block In Ward No.-173 ( Greater Kailash ) / South Zone 2 15.56:Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 3 13.1.2:12 Mm Cement Plaster Of Mix:1:6 ( 1 Cement : 6 Fine Sand ) . 4 13.90.1:Distempering With 1St Quality Acrylic Distember ( Ready Mix ) Having Voc Content Less Than 50 Grams / Litre Of Approved Brand And Manufacture To Give An Even Shade : Old Work ( One Or More Coats ) 5 9.21.3:Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non- Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:25 Mm Thick ( For Cupboard ) Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws 6 13.26:Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. 7 13.61.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 8 9.40.2.1:Providing And Fixing Wooden Moulded Beading To Door And Window Frames With Iron Screws, Plugs And Priming Coat On Unexposed Surface Etc. Complete:Kiln Seasoned And Chemically Treated Hollock Wood50x12 Mm 9 8.31:Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By EngineerIn-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 10 17.2.1:Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 11 17.35.1.1:Providing And Fixing Soil, Waste And Vent Pipes:100 Mm Diasand Cast Iron S & S Pipe As Per Is : 1729 12 15.23.1:Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm 13 14.2.1:Fixing Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15 X 10 X 10 Cm With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) , Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In-Charge.Door Chowkhats 14 11.56.1:Providing And Laying Polished Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing , Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. 15 18.75.1:Providing And Fixing Ptmt Extension Nipple For Water Thank Pipe, Fittings Of Approved Quality And Colour .15 Mm Nominal Bore Weighing Not Less Than 32 Gms 16 11.41.2:Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 17 9.62.1:Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete:300X16 Mm 18 9.63.2:Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, ( Barrel Type ) With Necessary Screws Etc. Complete:200X10 Mm 19 13.72:Washed Stone Grit Plaster On Exterior Walls Height Upto 10 Metre Above Ground Level, In Two Layers, Under Layer 12 Mm Cement Plaster 1:4 ( 1 Cement : 4 Coarse Sand ) , Furrowing The Under Layer With Scratching Tool, Applying Cement Slurry On The Under Layer @ 2 Kg Of Cement Per Square Metre, Top Layer 15 Mm Cement Plaster 1:1 / 2:2 ( 1 Cement : 1 / 2 Coarse Sand : 2 Stone Chipping 10 Mm Nominal Size ) , In Panels With Groove All Around As Per Approved Pattern Including Scrubbing And Washing The Top Layer With Brushes And Water To Expose The Stone Chippings, Complete As Per Specification And Direction Of Engineer-In-Charge ( Payment For Providing Grooves Shall Be Made Separately ) . 20 9.66.1:Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is : 4992 With Necessary Screws Etc. Complete:125 Mm 21 9.97.5:Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per : 1868 ) , Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:100X10 Mm 22 18.7.1:Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge.Internal Work - Exposed On Wall15 Mm Nominal Dia Pipes 23 9.100.2:Providing And Fixing Aluminium Handles, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:100 Mm 24 9.101.1:Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Single Rubber Stopper 25 21.1.2.3:Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micorn ) 26 10.25.2:Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 27 9.5.2.2:Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. ( Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately ) Kiln Seasoned And Chemically Treated Hollock Wood30 Mm Thick Shutters 28 9.48.2:Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc 29 9.7.3.1:Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) , Panelling For Panelled Or Panelledand Glazed Shutters 25 Mm To 40 Mm Thick:Ply Wood 5 Ply, 9 Mm Thickdecorative Plywood Both Side Decorative Veneer ( Type - I ) Conforming To Is 1328 Bwr Type. 30 17.10.2.2:Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:Kitchen Sink Without Drain Board610x460 Mm Bowl Depth 200 Mm 31 9.7.7.1:Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) , Panelling For Panelled Or Panelledand Glazed Shutters 25 Mm To 40 Mm Thick:Float Glass Panes4 Mm Thick Glass Pane ( Weight Not Less Than 10Kg / Sqm ) . 32 17.13.2:Providing And Fixing White Vitreous China Water Closet Squatting Pan ( Indian Type ) :Orissa Pattern W.C. Pan Of Size 580X440 Mm 33 17.25.1:Providing And Fixing White Vitreous China Wash Basin Including Making All Connectionsbut Excluding The Cost Of Fittings:Flat Back Wash Basin Of Size 630X450 Mm 34 17.18.1:Providing And Fixing P.V.C. Low Level Flushing Cistern With Manually Controlled Device ( Handle Lever ) Conforming To Is: 7231, With All Fittings And Fixtures Complete.10 Litre Capacity - White 35 17.22A:Providing And Fixing Cp Brass 32Mm Size Bottle Trap Of Approved Quality & Make And As Per The Direction Of Engineer In Charge. 36 17.28.2.2:Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete.Flexible Pipe40 Mm Dia 37 17.32.2:Providing And Fixing Mirror Of Superior Glass ( Of Approved Quality ) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing :Rectangular Shape 453X357 Mm 38 17.34.1:Providing And Fixing Toilet Paper Holder:C.P. Brass 39 18.8.1:Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15 Mm Nominal Dia Pipes 40 18.9.9:Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching , Refilling & Testing Of Joints Complete As Per Direction Of Engineer- In-Charge.External Work100 Mm Nominal Dia Pipes 41 18.10.1:Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc. Internal Work- Exposed On Wall15 Mm Dia Nominal Bore 42 18.18.1:Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete:15 Mm Nominal Bore 43 18.21.2.1:Providing And Fixing Uplasticised Pvc Connectionpipe With Brass Unions:45 Cm Length15 Mmnominal Bore 44 18.22.2:Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet:150 Mm Diameter 45 18.47.1:Providing And Fixing G.I Union In Existing G.I Pipe Line, Cutting And Threading The Pipe And Making Long Screws, Including Excavation, Refilling The Earth Or Cutting Of Wall And Making Good The Same Complete Wherever Required:15 Mm Nominal Bore 46 18.49.1:Providing And Fixing C.P Brass Bib Cock Of Approved Quality Conforming To Is: 8931.15 Mm Nominal Bore 47 18.50.1:Providing And Fixing C.P Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms.15 Mm Nominal Bore 48 18.52.1:Providing And Fixing C.P Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is: 893115 Mm Nominal Bore 49 18.53.1:Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 50 18.53A:Providing And Fixing C.P. Brass Extension Nipple ( Size 15Mmx50mm ) Of Approved Make And Quality As Per Direction Of Engineer-In-Charge. 51 18.78:Making Chases Up To 7.5X7.5 Cm In Walls Including Making Good And Finishing With Matching Surface After Housing G.Il Pipe Etc. 52 1.1.1_10:Disposal Of Materials By Mechanical Transportincluding Loading , Unloading And Stacking Lime , Moorum, Buildingrubbish Lead For 10 Km
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
45.
Science and Technology #10618785 Price Bid
Supply , Installation , Testing And Commissioning Of Laboratory Furniture - 2 Room No.-309 3 Granite Worktop & Skirting 4 Supply & Fixing Jet Black Granite Top 20 ( ±2 ) Mm Thick Superior Quality. The Overall Hanging Of Granite Is 25 Mm At Front Side Of Under Structure. Drip Lining Below The Tops At 15Mm From The Edge 5 Granite Skirting; 100 Mm Height; 20 ( ±2 ) Mm Thick 6 C- Frame & Modules Details Table Wise, Size Depth 770 ( ±20 ) Mm, Ht. 900 Mm 7 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 8 C-Frame For Wall Table - Depth 900 Mm X 900 Mm ( H ) 9 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 10 C-Frame For Corner Unit - Depth 900 Mm X 900 Mm ( H ) 11 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 12 C- Frame & Modules Details Table Wise, Size Depth 670 ( ±10 ) Mm, Ht. 750 Mm 13 C-Frame For Wall Table - Depth 650 Mm X 750 Mm ( H ) 14 Modules On C-Frame ( 570 Mm D X 635Mm H ) Approx. ( Castors Type ) 15 One Drawer & One Shutter- 450Mm W ( 535 Mm D X 535Mm H ) 16 One Drawer & Two Shutters- 600Mm W 17 One Drawer & Two Shutters- 750Mm W 18 One Shutter Corner Unit- 900Mm L X 900Mm W 19 Filler Panel / Closing Panles 20 900 H Table ( Side / Back Panel ) 21 750 H Table ( Side / Back Panel ) 22 Reagent Rack 23 Reagent Rack Wall Table:- 2 Tier Structure With Provision For Switch And Socket . Both Shelves Will Have 3Mm Friction Glass Fixing On Top 24 Size:-2500Mml X 210Mmw X 750Mmh 25 Sink / Peg Board / Taps / Utility 26 Big Pp Sink Outer Size: 22 L X 18 W X 12 D & Inner Size: 19 L X 15W X 11 D 27 Peg Board Big Size: 750Mm L X 750Mm H ( 30 Pegs. ) With Ss Collection Tray. 28 One Way Mixer Water Tap- ( Far-Italy ) ( Hot & Cold ) 29 Pvc Waste Pipe 30 Cpvc Pipe 15Mm Dia With Connection For Sink 31 Pvc Drain Pipe 3 Dia 32 Ptmt Stop Cock 15Mm Dia 33 Electric Geyser ( Instant Type ) , 3 Lpm, 3 Kw, 6 Lts. Tank Capacity, Fibre / Metalic Body Of 69.5 Deg C Temperature Output, Including Source Connector ( Pprc ) , Electrical Fitting As Per Requirement Complete. 34 Electrical Trunking ( Box Structure ) 35 Electrical Trunking:- Box Structure Single Side With Provision For Switch And Socket Fittings. ( Wall Table ) 36 Size:- 5800Mml X 120Mm W X 120 Mmh 37 Size:- 600Mml X 120Mm W X 120 Mmh 38 Size:- 2100Mml X 120Mm W X 120 Mmh 39 Switch / Sockets 40 Electrical 6 Pin Shutter Socket With Piano Switch Including Module Plate 5 / 15A , ( Northwest / Norisys Make ) With Wiring ( 2.5 Sq.Mm Frls ) 41 Data Point With Wiring ( Cat-6 Wire ) 42 Voice Point With Wiring ( 0.5 Sq. Mm Fr ) 43 Storage Cabinets 44 Wall Mounted Overhead File Cabinets ( Float Glass Door ) Gi Structure Two Shutter With One Adjustable Shelf Size:- 750Lmm X 370Mm W X 750 Mmh ( Approx. ) 45 Lab Furniture 46 Medium Back Chair On Castors, 4 Bend Pu Arms, Chrome Plated Pipe Frame & Base, Synchro Mechanism & Gas Lift, Seat And Back Letherite Tapestry. 47 Visitor Chair, Pu Arms, Pipe Frame , Seat And Back Letherite Tapestry. 48 High Rise Revolving Stool ( Black Seat Cover ) With Cushion In Seat & Lumber Support At Back, Metal Stand With Ring Type Foot Rest & Castors & Gas Lift 49 Electrical Work 50 Electrical Point 51 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Type Switch, Phenolic Laminated Sheet, Suitable Size G.I. Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. ( 12 No For Room No.-306 ) 52 Group C 53 Light / Fan / Exhaust And Accessories 54 Supplying And Fixing Of 2X2 Recess Mounted Led Fixture With 25-30 Watts Lamp ( Make - Phillips / Bajaj / Crompton Greaves / Havells / Wipro ) ( 4 No For Room No.-306 ) 55 Supply And Fixing Of Wall Mountain Fan 16 . ( Make- Bajaj / Crompton Greaves / Havells ) ( 5 No For Room No.-306 ) 56 Miscellaneous 57 Dismantling Of Old Type Ceramic Tile In Floor Area And Supply And Fixing Vitrified Tiles In ( Sizes 600 X 600 Mm ) On Same Place As Per Specification. ( Room Size 8.10 M X 4.30 M ) 58 Re-Fixing Tiled False Ceiling Of Specified Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections With 12.5 Mm Thick Square Edge Pvc Laminated Gypsum Tile Of Size 595X595 Mm, Made Of Gypsum Plasterboard, Manufactured From Natural Gypsumas Per Specification / Direction Of Engineer In-Charge. ( Room Size 8.10 M X 4.30 M ) 59 Supply And Fixing Aluminium Work And Partitions / Doors With Extruded Built Up Standard Tubular Sectionswith Various Size 80Mm / 60Mm / 40Mm And Thickness 2.8-3 Mm. Anodised Aluminium / Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides At Epdm Rubber / Neoprene Gasket Etc. Providing Fixing In Bottem Portion 12 Mm Thick Prelaminated Particle Board / Pvc Sheet / Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is:Glazing / Paneling, C.P. Brass / Stainless Steel Screws, And Fixing Float Glass Panes Of 5 Mm Thicknessglazing In Aluminium Partation, Door Shutters Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling, Hardware, Hingess, And Dash Fasteners Is Including Of These Item ) 60 Supply Installation, Testing & Commissioning Of 2.0 Ton Window A.C ( 5 Star Rating ) With 4 Mm Copper Wire ( 15 Mtr. ) , Pvc Condute, 16 Amp Rating, 240 / 415 Volts Mcb With Mcb Box Connections, Etc. As Required. Make:- Blue Star, Voltas, Daikin, Hitachi, Haier 61 Supply Installation, Testing & Commissioning Of 1.5 Ton Split Inverter A.C ( 5 Star Rating ) With 4 Mm Copper Wire ( 15 Mtr. ) , Pvc Condute, 16 Amp Rating, 240 / 415 Volts Mcb With Mcb Box Connections, Etc. As Required. Make:- Blue Star, Voltas, Daikin, Hitachi, Haier 62 Amc Charges For 1St Year 63 Amc Charges For 2Nd Year 64 Amc Charges For 3Rd Year 65 Amc Charges For 4Th Year 66 Amc Charges For 5Th Year 67 Room No. 309 68 Room No.-306 And 326 69 Granite Worktop & Skirting 70 Supply & Fixing Jet Black Granite Top 20 ( ±2 ) Mm Thick Superior Quality. The Overall Hanging Of Granite Is 25 Mm At Front Side Of Under Structure. Drip Lining Below The Tops At 15Mm From The Edge 71 Granite Skirting; 100 Mm Height; 20 ( ±2 ) Mm Thick 72 C- Frame & Modules Details Table Wise, Size Depth 770 ( ±20 ) Mm, Ht. 900 Mm 73 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 74 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 75 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 76 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 77 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 78 C- Frame & Modules Details Table Wise, Size Depth 670 ( ±10 ) Mm, Ht. 750 Mm 79 C-Frame For Wall Table - Depth 650 Mm X 750 Mm ( H ) 80 Modules On C-Frame ( 570 Mm D X 635Mm H ) Approx. ( Castors Type ) 81 One Drawer & One Shutter- 450Mm W ( 535 Mm D X 535Mm H ) 82 One Drawer & Two Shutters- 600Mm W 83 One Drawer & Two Shutters- 750Mm W 84 One Shutter Corner Unit- 900Mm L X 900Mm W 85 Filler Panel / Closing Panles 86 900 H Table ( Side / Back Panel ) 87 750 H Table ( Side / Back Panel ) 88 Reagent Rack 89 Reagent Rack Wall Table:- 2 Tier Structure With Provision For Switch And Socket . Both Shelves Will Have 3Mm Friction Glass Fixing On Top 90 Size:-2500Mml X 210Mmw X 750Mmh 91 Sink / Peg Board / Taps / Utility 92 Big Pp Sink Outer Size: 22 L X 18 W X 12 D & Inner Size: 19 L X 15W X 11 D 93 Peg Board Big Size: 750Mm L X 750Mm H ( 30 Pegs. ) With Ss Collection Tray. 94 One Way Mixer Water Tap- ( Far-Italy ) ( Hot & Cold ) 95 Pvc Waste Pipe 96 Cpvc Pipe 15Mm Dia With Connection For Sink 97 Pvc Drain Pipe 3 Dia 98 Ptmt Stop Cock 15Mm Dia 99 Electric Geyser ( Instant Type ) , 3 Lpm, 3 Kw, 6 Lts. Tank Capacity, Fibre / Metalic Body Of 69.5 Deg C Temperature Output, Including Source Connector ( Pprc ) , Electrical Fitting As Per Requirement Complete. 100 Electrical Trunking ( Box Structure ) 101 Electrical Trunking:- Box Structure Single Side With Provision For Switch And Socket Fittings. ( Wall Table ) 102 Size:- 5800Mml X 120Mm W X 120 Mmh 103 Size:- 600Mml X 120Mm W X 120 Mmh 104 Size:- 2100Mml X 120Mm W X 120 Mmh 105 Switch / Sockets 106 Electrical 6 Pin Shutter Socket With Piano Switch Including Module Plate 5 / 15A , ( Northwest / Norisys Make ) With Wiring ( 2.5 Sq.Mm Frls ) 107 Data Point With Wiring ( Cat-6 Wire ) 108 Voice Point With Wiring ( 0.5 Sq. Mm Fr ) 109 Glassware Storage Cabinets ( Gsc ) 110 Glassware Storage Cabinets ( Gsc ) In Crca Ms / Gi Structure Gi Structure Epoxy Powder Coated Construction, Five Nos. Adjustable Shelf, Double Skin Glass Doors With Ss Handles, Size:-1000Lmm X 450Mm W X 2100 Mmh ( Approx. ) 111 Storage Cabinets 112 Wall Mounted Overhead File Cabinets ( Float Glass Door ) Gi Structure Two Shutter With One Adjustable Shelf Size:- 750Lmm X 370Mm W X 750 Mmh ( Approx. ) 113 Lab Furniture 114 Table With Top ( 1500 X 750 Mm ) Shall Be 25Mm Thick Plain Particle Board Clad With 0.6Mm Thick Post Formed Laminate And 1Mm Thick Backing Laminate And Flat Edge Duly Sealed With 2Mm Thick Pvc Beading, 115 Medium Back Chair On Castors, 4 Bend Pu Arms, Chrome Plated Pipe Frame & Base, Synchro Mechanism & Gas Lift, Seat And Back Letherite Tapestry. 116 Visitor Chair, Pu Arms, Pipe Frame , Seat And Back Letherite Tapestry. 117 High Rise Revolving Stool ( Black Seat Cover ) With Cushion In Seat & Lumber Support At Back, Metal Stand With Ring Type Foot Rest & Castors & Gas Lift 118 Sliding Door Unit ( 1200Mm ( W ) X450mm ( D ) X1200mm ( H ) ) 119 Room No.-326 120 Granite Worktop & Skirting 121 Supply & Fixing Jet Black Granite Top 20 ( ±2 ) Mm Thick Superior Quality. The Overall Hanging Of Granite Is 25 Mm At Front Side Of Under Structure. Drip Lining Below The Tops At 15Mm From The Edge 122 Granite Skirting; 100 Mm Height; 20 ( ±2 ) Mm Thick 123 C- Frame & Modules Details Table Wise, Size Depth 770 ( ±20 ) Mm, Ht. 900 Mm 124 C-Frame For Island Table- Depth-1500Mm X 900 Mm ( H ) 125 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 126 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 127 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 128 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 129 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 130 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 131 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 132 C- Frame & Modules Details Table Wise, Size Depth 670 ( ±10 ) Mm, Ht. 750 Mm 133 C-Frame For Wall Table - Depth 650 Mm X 750 Mm ( H ) 134 Modules On C-Frame ( 570 Mm D X 635Mm H ) Approx. ( Castors Type ) 135 One Drawer & One Shutter- 450Mm W ( 535 Mm D X 535Mm H ) 136 One Drawer & Two Shutters- 600Mm W 137 One Drawer & Two Shutters- 750Mm W 138 One Shutter Corner Unit- 900Mm L X 900Mm W 139 Filler Panel / Closing Panles 140 900 H Table ( Side / Back Panel ) 141 750 H Table ( Side / Back Panel ) 142 Reagent Rack 143 Reagent Rack Island Table :- 2 Tier Structure With Provision For Switch And Socket Cutout Provision. Both Shelves Will Have 3Mm Friction Glass Fixing On Top. Two Shelves Of 380 Mm Depth Are Adjustable And Part Will Have Storage Cabinet Aggange. 144 Size:- 5200Lmm X 400 / 380 + 300Mmw X 1200 H 145 Sink / Peg Board / Taps / Utility 146 Big Pp Sink Outer Size: 22 L X 18 W X 12 D & Inner Size: 19 L X 15W X 11 D 147 Peg Board Big Size: 750Mm L X 750Mm H ( 30 Pegs. ) With Ss Collection Tray. 148 One Way Water Tap- ( Far-Italy ) 149 Pvc Waste Pipe 150 Cpvc Pipe 15Mm Dia With Connection For Sink 151 Pvc Drain Pipe 3 Dia 152 Ptmt Stop Cock 15Mm Dia 153 Electrical Trunking ( Box Structure ) 154 Electrical Trunking:- Box Structure Single Side With Provision For Switch And Socket Fittings. ( Wall Table ) 155 Size:- 5300Mml X 120Mm W X 120 Mmh 156 Size:- 1800Mml X 120Mm W X 120 Mmh 157 Size:- 2400Mml X 120Mm W X 120 Mmh 158 Size:- 3200Mml X 120Mm W X 120 Mmh 159 Switch / Sockets 160 Electrical 6 Pin Shutter Socket With Piano Switch Including Module Plate 5 / 15A , ( Northwest / Norisys Make ) With Wiring ( 2.5 Sq.Mm Frls ) 161 Data Point With Wiring ( Cat-6 Wire ) 162 Voice Point With Wiring ( 0.5 Sq. Mm Fr ) 163 Glassware Storage Cabinets ( Gsc ) 164 Glassware Storage Cabinets ( Gsc ) In Crca Ms / Gi Structure Gi Structure Epoxy Powder Coated Construction, Five Nos. Adjustable Shelf, Double Skin Glass Doors With Ss Handles, Size:-1000Lmm X 450Mm W X 2100 Mmh ( Approx. ) 165 Storage Cabinets 166 Wall Mounted Overhead File Cabinets ( Float Glass Door ) Gi Structure Two Shutter With One Adjustable Shelf Size:- 750Lmm X 370Mm W X 750 Mmh ( Approx. ) 167 Lab Furniture 168 Medium Back Chair On Castors, 4 Bend Pu Arms, Chrome Plated Pipe Frame & Base, Synchro Mechanism & Gas Lift, Seat And Back Letherite Tapestry. 169 High Rise Revolving Stool ( Black Seat Cover ) With Cushion In Seat & Lumber Support At Back, Metal Stand With Ring Type Foot Rest & Castors & Gas Lift 170 Miscellaneous 171 Dismantling Of Old Type Ceramic Tile In Floor Area And Supply And Fixing Vitrified Tiles In ( Sizes 600 X 600 Mm ) On Same Place As Per Specification. ( Room Size 8.10 M X 4.25 M ) 172 Re-Fixing Tiled False Ceiling Of Specified Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections With 12.5 Mm Thick Square Edge Pvc Laminated Gypsum Tile Of Size 595X595 Mm, Made Of Gypsum Plasterboard, Manufactured From Natural Gypsumas Per Specification / Direction Of Engineer In-Charge. ( Room Size 8.10 M X 4.25 M ) 173 Supply And Fixing Aluminium Work And Partitions / Doors With Extruded Built Up Standard Tubular Sectionswith Various Size 80Mm / 60Mm / 40Mm And Thickness 2.8-3 Mm. Anodised Aluminium / Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides At Epdm Rubber / Neoprene Gasket Etc. Providing Fixing In Bottem Portion 12 Mm Thick Prelaminated Particle Board / Pvc Sheet / Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is:Glazing / Paneling, C.P. Brass / Stainless Steel Screws, And Fixing Float Glass Panes Of 5 Mm Thicknessglazing In Aluminium Partation, Door Shutters Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling, Hardware, Hingess, And Dash Fasteners Is Including Of These Item ) 174 Supply Installation, Testing & Commissioning Of 2.0 Ton Window A.C ( 5 Star Rating ) With 4 Mm Copper Wire ( 15 Mtr. ) , Pvc Condute, 16 Amp Rating, 240 / 415 Volts Mcb With Mcb Box Connections, Etc. As Required. Make:- Blue Star, Voltas, Daikin, Hitachi, Haier 175 Supply Installation, Testing & Commissioning Of 1.5 Ton Split Inverter A.C ( 5 Star Rating ) With 4 Mm Copper Wire ( 15 Mtr. ) , Pvc Condute, 16 Amp Rating, 240 / 415 Volts Mcb With Mcb Box Connections, Etc. As Required. Make:- Blue Star, Voltas, Daikin, Hitachi, Haier 176 Amc Charges For 1St Year 177 Amc Charges For 2Nd Year 178 Amc Charges For 3Rd Year 179 Amc Charges For 4Th Year 180 Amc Charges For 5Th Year 181 Total Room No. 306 And 326 182 Granite Worktop & Skirting : Formulation Laboratory ( Room No.-258 ) 183 Supply & Fixing Jet Black Granite Top 20 ( ±2 ) Mm Thick Superior Quality. The Overall Hanging Of Granite Is 25 Mm At Front Side Of Under Structure. Drip Lining Below The Tops At 15Mm From The Edge 184 Granite Skirting; 100 Mm Height; 20 ( ±2 ) Mm Thick 185 C- Frame & Modules Details Table Wise, Size Depth 770 ( ±20 ) Mm, Ht. 900 Mm 186 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 187 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 188 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 189 C- Frame & Modules Details Table Wise, Size Depth 670 ( ±10 ) Mm, Ht. 750 Mm 190 C-Frame For Wall Table - Depth 650 Mm X 750 Mm ( H ) 191 Modules On C-Frame ( 570 Mm D X 635Mm H ) Approx. ( Castors Type ) 192 One Drawer & One Shutter- 450Mm W ( 535 Mm D X 535Mm H ) 193 One Drawer & Two Shutters- 750Mm W 194 One Drawer & Two Shutters- 600Mm W 195 One Shutter Corner Unit- 900Mm L X 900Mm W 196 Filler Panel / Closing Panles 197 750 H Table ( Side / Back Panel ) 198 Sink / Peg Board / Taps / Utility 199 Big Pp Sink Outer Size: 22 L X 18 W X 12 D & Inner Size: 19 L X 15W X 11 D 200 Peg Board Big Size: 750Mm L X 750Mm H ( 30 Pegs. ) With Ss Collection Tray. 201 One Way Water Tap 202 Pvc Waste Pipe 203 Cpvc Pipe 15Mm Dia With Connection For Sink 204 Pvc Drain Pipe 3 Dia 205 Ptmt Stop Cock 15Mm Dia 206 Electrical Trunking ( Box Structure ) 207 Electrical Trunking:- Box Structure Single Side With Provision For Switch And Socket Fittings. ( Wall Table ) 208 Size:- 3200Mml X 120Mm W X 120 Mmh 209 Size:- 750Mml X 120Mm W X 120 Mmh 210 Size:- 2600Mml X 120Mm W X 120 Mmh 211 Switch / Sockets / Copper Wiring 212 Electrical 6 Pin Shutter Socket With Piano Switch Including Module Plate 5 / 15A , ( Northwest / Norisys Make ) With Wiring ( 2.5 Sq.Mm Frls ) 213 Data Point With Wiring ( Cat-6 Wire ) 214 Storage Cabinets 215 Wall Mounted Overhead File Cabinets ( Float Glass Door ) Gi Structure Two Shutter With One Adjustable Shelf Size:- 750Lmm X 370Mm W X 750 Mmh ( Approx. ) 216 Lab / Office Furniture 217 Medium Back Chair On Castors, 4 Bend Pu Arms, Chrome Plated Pipe Frame & Base, Synchro Mechanism & Gas Lift, Seat And Back Letherite Tapestry. 218 Visitor Chair, Pu Arms, Pipe Frame , Seat And Back Letherite Tapestry. 219 High Rise Revolving Stool ( Black Seat Cover ) With Cushion In Seat & Lumber Support At Back, S S Metal Stand With Ring Type Foot Rest & Castors & Gas Lift 220 Table With Top ( 1500 X 750 Mm ) Shall Be 25Mm Thick Plain Particle Board Clad With 0.6Mm Thick Post Formed Laminate And 1Mm Thick Backing Laminate And Flat Edge Duly Sealed With 2Mm Thick Pvc Beading, 221 Sliding Door Unit ( 1200Mm ( W ) X450mm ( D ) X1200mm ( H ) ) 222 Class Ii Biological Safety Cabinet 223 Bio Safety Cabinet Class Ii, Fitted With Ulpa / Hepa Filters With Min 99% Efficiency Against 0.3 Μm Particles. Automatic Balance Of Inflow & Downflow Air Velocities. Digital Airflow Verification Alarm, Tested & Certified To Nsf / Ansi 49. Size 1200 X 900 X 2400 ( Lxwxh ) , As Per Attached Specification. 224 Supply Installation, Testing & Commissioning Of 2.0 Ton Split Inverter A.C ( 5 Star Rating ) With 4 Mm Copper Wire ( 15 Mtr. ) , Pvc Condute, 16 Amp Rating, 240 / 415 Volts Mcb With Mcb Box Connections, Etc. As Required. Make:- Blue Star, Voltas, Daikin, Hitachi, Haier 225 Amc Charges For 1St Year 226 Amc Charges For 2Nd Year 227 Amc Charges For 3Rd Year 228 Amc Charges For 4Th Year 229 Amc Charges For 5Th Year 230 Total Formulation Lboratory ( Room No. 258 ) 231 Granite Worktop & Skirting: Microbial Biochemistry Division 232 Work Surface -18 / 19 Mm Thick Superior Quality Jet Black Granite . The Overall Hanging Of Granite Is 25 Mm At Front Side Of Under Structure. Drip Lining Below The Tops At 15Mm From The Edge 233 Granite Skirting; 100 Mm Height; 18 / 19 Mm Thick 234 C-Frame Details Table Wise 235 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 236 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 237 C-Frame For Wall Table - Depth 750 Mm X 900 Mm ( H ) 238 C-Frame For Isaland Table - Depth 1500 Mm X 900 Mm ( H ) 239 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 240 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 241 C-Frame For Corner Unit - Depth 750 Mm X 900 Mm ( H ) 242 C-Frame For Wall Table - Depth 650 Mm X 750 Mm ( H ) 243 C-Frame For Wall Table - Depth 650 Mm X 750 Mm ( H ) 244 C-Frame For Corner Unit - Depth 650 Mm X 750 Mm ( H ) 245 Modules On C-Frame With Castors Type ( 535Mm D X 635Mm H ) Approx. 246 One Drawer & Two Shutters- 600Mml 247 One Drawer & Two Shutters- 750Mml 248 One Shutter Corner Unit- 900Mml X 900Mml 249 Modules On C-Frame With Castors Type ( 535Mm D X 570Mm H ) Approx. 250 One Drawer & One Shutters- 450Mml 251 One Shutter Corner Unit- 800Mml X 800Mml 252 Flexis Gap Closing Panles 253 900 H Table ( Side Panel ) 538 W X 726 H 254 900 H Table ( Side Panel ) 1320 W X 726 H 255 750 H Table ( Side Panel ) 425 W X 610 H 256 Leg Space / Foot Rest / Key Board 257 Leg Space With Foot Rest And Back Panel :- 600Mm 258 Reagent Rack 259 Reagent Rack Island Table :- 2 Tier Structure With Provision For Switch And Socket Cutout Provision. Both Shelves Will Have 3Mm Friction Glass Fixing On Top. Two Shelves Of 380 Mm Depth Are Adjustable And Part Will Have Storage Cabinet Aggange. 260 Size:- 3000Lmm X 400 / 380 + 300Mmw X 1200 H 261 Sink - Big 262 Big Pp Sink Outer Size: 22 L X 18 W X 12 D & Inner Size: 19 L X 15W X 11 D 263 Waste For Pp Drop In Sink, Color-Black ( Size : 38 X 76Mm Dia. ) 264 Anti-Siphon Bottle Trap, Size : 38Mm Dia. ( Black Color ) 265 Peg Board 266 Peg Board Big Size: 750Mm L X 750Mm H ( 30 Pegs. ) With Ss Collection Tray. 267 Taps 268 One Way Water Tap-Gooseneck 269 Cpvc Pipe 15Mm Dia With Connection For Sink 270 Pvc Drain Pipe 3 Dia With Conection Complete 271 Ptmt Stop Cock 15Mm Dia 272 Electrical Trunking ( Box Structure ) 273 Electrical Trunking:- Box Structure Single Side With Provision For Switch And Socket Fittings. ( Wall Table ) 274 Size:- 3300Mml X 120Mm W X 120 Mmh 275 Size:- 1350Mml X 120Mm W X 120 Mmh 276 Size:- 1350Mml X 120Mm W X 120 Mmh 277 Size:- 1050Mml X 120Mm W X 120 Mmh 278 Size:- 900Mml X 120Mm W X 120 Mmh 279 Size:- 1800Mml X 120Mm W X 120 Mmh 280 Size:- 1350Mml X 120Mm W X 120 Mmh 281 Switch / Sockets 282 Electrical Socket With Piano Switch 5 / 15Amp ( Northwest / Norisys Make ) Without Wiring 283 Data Point Without Wiring 284 Copper Wiring 285 1.5 Sq. Mm For Switch & Socket 5 / 15 Amp 286 2.5 Sq. Mm For Switch & Socket 5 / 15 Amp 287 Cat-6 Wire For Data Point 288 Class Ii Biological Safety Cabinet 289 External Size: Width 4 To 4.5 Feet, Depth 2.4 To 3.5 Feet Height 4.5 To 5 Feet, Internal Size: Width 4 To 4.5 Feet, Depth 1.8 To 2.0 Feet, Height 2.0 To 2.3 Feet ( See Enclosed Details Specification ) N 290 Storage Cabinets 291 Wall Mounted Overhead File Cabinets ( Float Glass Door ) Gi Structure Two Shutter With One Adjustable Shelf Size:- 750Lmm X 370Mm W X 750 Mmh ( Approx. ) 292 Lab Chairs 293 Medium Back Chair On Castors, 4 Bend Pu Arms, Chrome Plated Pipe Frame & Base, Synchro Mechanism & Gas Lift, Seat And Back Letherite Tapestry. 294 Visitor Chair, Pu Arms, Pipe Frame , Seat And Back Letherite Tapestry. 295 High Rise Revolving Stool ( Black Seat Cover ) With Cushion In Seat & Lumber Support At Back, Metal Stand With Ring Type Foot Rest & Castors & Gas Lift 296 Table With Top ( 1500 X 750 Mm ) Shall Be 25Mm Thick Plain Particle Board Clad With 0.6Mm Thick Post Formed Laminate And 1Mm Thick Backing Laminate And Flat Edge Duly Sealed With 2Mm Thick Pvc Beading, Three Drawers Of Over All Size 390Mm ( Width ) X 585Mm ( Depth ) X 656Mm ( Height ) Consisting Of Two Utility Drawers And One Filling Box Drawer. Side Unit As Per Drawing Ref; 900 Mmx 520Mm 302 Total Microbial Bio-Chemistry Division
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
Jammu And Kashmir View Result →
46.
Rural Development #10583263 Price Bid
Providing Supplying And Erecting Various Material And Machinery And Labour Services For Fhtc At Grampanchayatmanerwadi-Haweli-2 40 / 60 Mm Metal 3 53Grade Cement 4 20Mm Metal 5 Crush Sand 6 Mrum 7 Pcc M-10 8 Pvc Coated Gi Wire 9 G.I. Pipe 15Mm Dia. Medium Type 10 G.I. Pipe 15Mm Dia. Heavy Type 11 G.I. Pipe 20Mm Dia. Medium Type 12 G.I. Pipe 20Mm Dia.Heavy Type 13 G.I. Pipe 25Mm Dia. Medium Type 14 G.I. Pipe 25Mm Dia. Heavy Type 15 G.I. Pipe 32Mm Dia. Medium Type 16 G.I. Pipe 32Mm Dia.Heavy Type 17 G.I. Pipe 40Mm Dia. Medium Type 18 G.I. Pipe 40Mm Dia. Heavy Type 19 G.I. Pipe 50Mm Dia. Medium Type 20 G.I. Pipe 50Mm Dia. Heavy Type 21 G.I. Pipe 65Mm Dia. Medium Type 22 G.I. Pipe 65Mm Dia. Heavy Type 23 G.I. Pipe 80Mm Dia. Medium Type 24 G.I. Pipe 80Mm Dia. Heavy Type 25 Pvc Nahani Trap 75 Mm 26 G.I.Clamps 100Mm To 150Mm 27 Pvc Nahani Trap 150 Mm 28 G.I.Clamps 12Mm To 32Mm 29 G.I.Clamps 40Mm To 80Mm 30 Anglo Indian W.C. Pan Colour 31 G.I.Fixtures 32 P.V.C. Cowl 100 Mm 33 G.I.Screws 30Mm 34 G.I.Screws 40Mm 35 G.I.Union 25Mm Dia. 36 Gully Trap Cover With Frame 37 Gun Metal Stop Tap With Crutch Wheel 20Mm 38 Gun Metal Stop Tap With Crutch Wheel 25Mm 39 Gun Metal Stop Tap With Crutch Wheel 15Mm 40 Gun Metal Stop Tap With Crutch Wheel 20Mm 41 C.I.Bend 75Mm Dia. 42 C.I.Bend 100Mm Dia. 43 C.I.Bip Tap 12Mm 44 C.I.Grating 150Mm Dia. 45 C.I.Grating 100Mm Dia. 46 C.I.Grating 75Mm Dia. 47 C.I.Brackets 48 C.I.Collers 100Mm Dia. 49 C.I.Copllers 75Mm Dia. 50 C.I.Cover 45*30 Cm With Frame 51 C.I.Cowl / Vent 100Mm Dia. 52 C.I.Cowl / Vent 150Mm Dia. 53 C.I.Cowl / Vent 75Mm Dia. 54 C.I.Hinged Cover With Frame 55 C.I.Man Hole Cover 50 Kg. 56 C.I.Man Hole Cover 75 Kg. 57 C.I.Man Hole Cover 100 Kg. 58 C.I.Man Hole Cover 175 Kg.Heavy ( 0.9*0.45M ) 59 C.I.Nahani Trap 100Mm Dia. ( 375Mm Long ) 60 C.I.Nahani Trap 75 To 80Mm Dia. ( 375Mm Long ) 61 C.I.100*75*300 Long Arm ( Wt. 6Kg ) Nahani Trap 62 C.I.Soil Pipe 100Mm Dia. 63 C.I.Soil Pipe 150Mm Dia. 64 C.I, Soil Pipe 75 To 80Mm Dia. 65 C.I.Shoe 75 Mm Dia. 66 C.I. Shoe 100 Mm Dia. 67 C.I.Shoe 150Mm 68 Ball Cock 15Mm Dia.P.V.C.Float 69 Ball Cock 25Mm Dia.P.V.C.Float 70 Ball Cock 40Mm Dia.P.V.C.Float 71 Ball Cock 50Mm Dia.P.V.C.Float 72 Bib Cock Stop Tap Brass Heavy 15Mm 73 Bib Cock Stop Tap Brass Heavy 20Mm 74 Bib Cockstop Tap Brass Heavy 25Mm 75 Bib Tap 12Mm Brass Medium 76 Colour Wash Hand Basin 55*40Cm 77 Colour Wash Hand Basin 63*45Cm 78 White Glazed Wash Basin 45*30Cm 79 White Glazed Wash Hand Basin 55*50Cm 80 P.V.C. Flexible Waste Pipe 32 Mm Dia 81 White Glazed Wash Hand Basin 63 X 45 Cm 82 Sink White Glazed 45*20*30Cm 83 Pedestal For Wash Basin ( Standard Size ) 84 C.C.Septic Tank 0.9M Dia. ( 2.5M Long ) 85 C.C.Septic Tank 1.20M Dia. ( 2.5M Long ) 86 C.I.Steps For Manhole 87 C.I.Cover With Frame ( Gully Trap ) 88 C.I.Plug Bend 150Mm Dia. 89 Clamp For G.I.Pipe 25Mm 90 Colour European Type W.C.Pan 91 European Type Glazed W.C.Pan 92 W.C.Pan Coloured Glazed 64Cm. ( Orissa ) 93 W.C.Pan White Glazed 58 Cm.Indian 94 W.C.Pan White Glazed 57.50 Cm ( Orissa ) 95 Fibre Flushing Tank For W.C. 96 Flushing Tank Automatic Urinal 10Ltr. C.I. 97 Flushing Tank Automatic Urinal 5Ltr. ( P.V.C. ) 98 Low Level Flush Pr. St. 10Ltr. 99 Flat Back Urinal 100 Stall Type Urinal 101 Lipped Type Urinal 102 Coloured Glazed Full Stall Urinal 103 Bleaching Powder 104 Potassium Permanganate 105 Nylon Brush 106 Duster 107 Plastic Bucket 108 Coir 109 Gunny Cloth 110 Kharata 111 Wheel Stop Tap Brass 15Mm 112 Wheel Stop Tap Brass 20Mm 113 Wheel Stop Tap Brass 25Mm 114 Socket Brass For 32Mm Tap 115 Socket Brass For 40Mm Tap 116 Socket Brass For 50Mm Tap 117 Socket Brass For 65Mm Tap 118 Socket For 100Mm Tap 119 Socket For 15Mm Tap 120 Socket For 20Mm Tap 121 Socket For 25Mm Tap 122 Socket For 32Mm Tap 123 Socket For 40Mm Tap 124 Socket For 50Mm Tap 125 Socket For 65Mm Tap 126 Socket For 80Mm Tap 127 Span Yarn 128 Strainer For 100Mm 129 Strainer For 40Mm 130 Strainer For 50Mm 131 Strainer For 80Mm 132 Strainer For 15Mm 133 Strainer For 20Mm 134 Strainer For 25Mm 135 Stone Ware Pipe 100Mm Dia. 136 Stone Ware Pipe 150Mm Dia. 137 Stone Ware Pipe 225Mm Dia. 138 Stone Ware Glazed Pipe Half Round 100Mm Dia. 139 Stop Tap Brass With Crunch Wheel 15Mm Dia. 140 Towel Rod With Clamps 16Mm Dia. 141 Mirror 40*50Cm. With Plastic Frame 142 Brass T Thimble Socket 32Mm Dia. 143 Brass Wheel Stop Tap 32Mm Dia. 144 Brass Wheel Stop Tap 40Mm Dia. 145 Brass Wheel Stop Tap 50Mm Dia. 146 Brass Wheel Stop Tap 65Mm Dia. 147 Brass Wheel Stop Tap 80Mm Dia. 148 Half Turn Flush Cock 25Mm Dia. 149 12Mm Flexible Inlet Pipe Connection 150 Bell Mouth Cover 100Mm Dia. 151 Box Chamber With Lock 0.6*0.45M 152 Brass Nozzle Pillar Tap 12Mm 153 Black Bakelite Seat To European Closer 154 Concussion Push Button Type Gun Metal Tap 15 To 25Mm Dia. 155 Coupling Cast Iron 100Mm Dia. 156 Coupling Cast Iron 80Mm Dia. 157 Chromium Plated 12Mm Dia.Bib Cock 158 C.I.Trap Grating 15*10 Cm 159 C.I.Y Junction 100Mm Dia. 160 C.I.Y Junction 150Mm Dia. 161 C.I.Y Junction 75Mm Dia. 162 Enameled Bend 40Mm Dia. 163 Ferrul For C.I.Pipr 100Mm 164 White Glazed Foot Rest Chequred 25*10 Cm 165 Half Round Earthware Pipe 100Mm ( 60Cm Long ) 166 Half Round Earthware Pipe 150Mm ( 60Cm Long ) 167 Jute Rope 168 Half Round Chaina Ware Pipe 100Mm ( 60Cm Long ) 169 Lead Pipe 32Mm Dia. 170 Mohagani Seat With Lid 171 Mosquito Proof Coupling 172 Non-Return Valve 15Mm For Water Meter 173 Non-Return Valve 25Mm For Water Meter 174 Non-Return Valve 20Mm For Water Meter 175 Piller Tap 12Mm Dia.Chromium Plated Heavy 176 P.Trap And Lead Pipe Upto 40Mm Dia. 177 Rubber Gasket ( 25, 28 And 20 Cm ) 178 Rubber Incertion 179 Rubberised Adhesive 180 Salt Glazed Stone Ware Gully Trap ( 150*150Mm ) 181 Self Project Tap Brass Chromium Plated 15Mm 182 Sewer Trap 183 Shower Rose Chromium Plated Brass 10Cm 184 P.V.C. Pipe 15Mm Dia.10Kg / Cm2 Pressure ( Class Iv ) 185 P.V.C. Pipe 20Mm Dia.10Kg / Cm2 Pressure ( Class Iv ) 186 P.V.C. Pipe 25Mm Dia.10Kg / Cm2 Pressure ( Class Iv ) 187 P.V.C. Pipe 32Mm Dia.10Kg / Cm2 Pressure ( Class Iv ) 188 P.V.C. Pipe 40Mm Dia.10Kg / Cm2 Pressure ( Class Iv ) 189 P.V.C. Pipe 50Mm Dia.10Kg / Cm2 Pressure ( Class Iv ) 190 P.V.C. Pipe 60Mm Dia.10Kg / Cm2 Pressure ( Class Iv ) 191 P.V.C. Pipe 75Mm Dia.4 Kg / Cm2 Pressure ( Class Ii ) 192 P.V.C. 75 Mm Soil Pipe 6 Kg / Cm2 Pressure 193 P.V.C. Pipe 90Mm Dia.4 Kg / Cm2 Pressure ( Class Ii ) 194 P.V.C.Pipe 110Mm Dia.4Kg / Cm2 Pressure ( Class Ii ) 195 P.V.C. 110 Mm Rain Water Pipe 6Kg / Cm2 Pressure 196 P.V.C. 110 Mm Soil Pipe 6 Kg / Cm2 Pressure 197 P.V.C.Pipe 140Mm Dia.4Kg / Cm2 Pressure ( Class Ii ) 198 P.V.C.Pipe 160Mm Dia.4Kg / Cm2 Pressure ( Class Ii ) 199 P.V.C.Pipe 160Mm Dia.Soil Pipe 200 P.V.C.Pipe 160Mm Dia. Rain Water Pipe 201 P.V.C.Socket 15Mm Dia. 202 P.V.C.Socket 20Mm Dia. 203 P.V.C.Socket 25Mm Dia. 204 P.V.C.Socket 32Mm Dia. 205 P.V.C.Socket 40Mm Dia. 206 P.V.C.Socket 50Mm Dia. 207 P.V.C.Socket 60Mm Dia. 208 P.V.C.Flushing Tank ( 12 Ltr. Capacity ) 209 Flush Valve 32Mm Dia. 210 Ferocret Tank 211 Stainless Steel Sink Of Size 600*510*200Mmof Nirali Or Equivalent Make 212 C.P.Pillar Cock Jaquar Make Continental ( Cat.No. Con-011 ) 213 C.P.Pillar Cock ( Isi ) Jaquar Make Continental 214 C.P.Pillar Cock Long Neck With Aerator Jaquar Make Continental ( Cat.No. Con- 021 ) 215 C.P.Bib Cock ( Isi ) Jaquar Make Continental ( Cat.No. Con-037 ) 216 C.P.Bib Cock Long Thread Jaquar Make Continental ( Cat.No. Con-039 ) 217 C.P.2-Way Bib Cock Jaquar Make Continental ( Cat.No. Con-041 ) 218 C.P.Bib Cock With Wall Flange Long Thread Jaquar Make Continental ( Cat.No. Con- 047 ) 219 C.P.Bib Cock With Nozzle Jaquar Make Continental ( Cat.No. Con-049 ) 220 C.P.Angular Stop Cockjaquar Make Continental ( Cat.No. Con-053 ) 221 C.P.Angular Stop Cock Long Thread Jaquar Make Continental ( Cat.No. Con-055 ) 222 C.P.Angular Stop Cock With Wall Flange Jaquar Make Continental ( Cat.No. Con- 059 ) 223 C.P.Central Hole Basin Mixer Without Popup Waste System With 450Mm Long Braided Hoses Jaquar Make Continental ( Cat.No. Con-167B ) 224 C.P.Wall Mixer With Telephone Shower Arragnementonly But Without Teltphone Shower Crutch Jaquar Make Continental ( Cat.No. Con-217 ) 225 C.P.Wall Mixer Non-Telephonic Shower Arrangement Jaquar Make Continental ( Cat.No. Con-219 ) 226 C.P.Wall Mixer ( Wall Mounted Model ) With Telephone Shower Arrangement Only And With Telephone Shower Crutch Jaquar Make Continental ( Cat.No. Con-267 ) 227 C.P.Wall Mixer With Provision For Overheadshower With 115Mm Long Bend Pipe And Wall Flange Jaquar Make Continental ( Cat.No. Con-273Upr ) 228 C.P.Sink Mixer With Swinging Casted Spout ( Wallmounted ) Jaquar Make Continental ( Cat.No. Con-309 ) 229 C.P.Sink Mixer Swinging Spout ( Table Mounted Model ) 450Mm Long Braided Hoses Jaquar Make Continental ( Cat.No. Con-309B ) 230 C.P.Sink Cock With Swinging Casted Spout Jaquar Make Continental ( Cat.No. Con- 347 ) 231 C.P.Sink Cock With Raised J Shaped Swinging Casted Spout ( Table Mounted ) Jaquar Make Continental ( Cat.No. Con- 359 ) 232 C.P.Shower Arm 190Mm Long Light Body With Wallflange Jaquar Make Continental ( Cat. No. Sha - 477 ) 233 C.P.Flush Cock With Wall Flange 25Mm With Plain Knob Jaquar Make Continental ( Cat.No. Flr 6081 ) 234 C.P.Towel Rail 24 Jaquar Make Continental ( Cat. No. Acn 1111N ) 235 C.P.Towel Ring Square Jaquar Make Continental ( Cat. No. Acn 1121N ) 236 C.P.Soap Dish Hooker Jaquar Make Continental ( Cat. No. Akb 35731 ) 237 C.P.Soap Dish ( Polyurethane ) Jaquar Make Continental ( Cat. No. Aqn 7733 ) 238 C.P.Toilet Paper Holder Jaquar Make Continental ( Cat. No. Aq 7751 ) 239 C.P.Toilet Rack 24With Lower Hanger Jaquar Make Continental ( Cat. No. Acn 1181N ) 240 C.P.Handshower ( Health Faucet ) 1M.Pvc Tube With Wall Hook Jaquar Make ( Cat. No. Ald 563 ) 241 C.P.Pillar Cock Jaquar Make QueenS Collection ( Quarter Turn Fitting ) ( Cat. No. Qqt 7011 ) 242 C.P.Bib Cock With Wall Flange Aqua Make QueenS Collection ( Quarter Turn Fitting ) ( Cat. No. Qqt7037 ) 243 C.P.2-Way Bib Cock With Wall Flange Aqua Make QueenS Collection ( Quarter Turn Fitting ) ( Cat. No. Qqt 7041 ) 244 C.P.Angular Stop Cock With Wall Flange Aqua Make QueenS Collection ( Quarter Turn Fitting ) ( Cat. No. Qqt 7053 ) 245 C.P.Central Hole Basin Mixer With Regular Spout Without Popup Waste System With 450Mm Longbraided Hoses Jaquar Make QueenS Collection ( Quarter Turn Fitting ) ( Cat. No. Qqt 7167Bb ) 246 C.P.Central Hole Basin Mixer With Regular Spout With Popup Waste System With 450Mm Longbraided Hoses Jaquar Make QueenS Collection ( Quarter Turn Fitting ) ( Cat. No. Qqt 7169B ) 247 C.P.Central Hole Basin Mixer With Small Spout Without Popup Waste System With 450Mm Longbraided Hoses Jaquar Make QueenS Collection ( Quarter Turn Fitting ) ( Cat. No. Qqt 7171B ) 248 C.P.Wall Mixer ( Wall Mounted Model ) With Telephonic Shower Arrangement Only But Without Crutchjaquar Make QueenS Collection ( Quarter Turn Filling ) ( Cat. No. Qqt 7217 ) 249 C.P.Wall Mixer Non-Telephonic Shower System Jaquar Make QueenS Collection ( Quarter Turn Filling ) ( Cat. No. Qqt 7219 ) 250 C.P.Wall Mixer ( Wall Mounted Model ) With Telephonic Shower Arrangement Only And With Telephone Shower Crutch Jaquar Make QueenS Collection ( Quarter Turn Filling ) ( Cat. No. Qqt 7267 ) 251 Hydraulic Door Closer 252 Cpvc Pipe 15Mm Dia. 253 Cpvc Pipe 20Mm Dia. 254 Cpvc Pipe 25Mm Dia. 255 Cpvc Pipe 32Mm Dia. 256 Cpvc Pipe 40Mm Dia. 257 Cpvc Pipe 50Mm Dia. 258 Cpvc Coupling For 15Mm Dia. 259 Cpvc Coupling For 20Mm Dia. 260 Cpvc Coupling For 25Mm Dia. 261 Cpvc Coupling For 32Mm Dia. 262 Cpvc Coupling For 40Mm Dia. 263 Cpvc Coupling For 50Mm Dia. 264 Elbow 90 Degree For 15Mm Dia. 265 Elbow 90 Degree For 20Mm Dia. 266 Elbow 90 Degree For 25Mm Dia. 267 Elbow 90 Degree For 32Mm Dia. 268 Elbow 90 Degree For 40Mm Dia. 269 Elbow 90 Degree For 50Mm Dia. 270 Tee For 15Mm Dia. 271 Tee For 20Mm Dia. 272 Tee For 25Mm Dia. 273 Tee For 32Mm Dia. 274 Tee For 40Mm Dia. 275 Tee For 50Mm Dia. 276 End Cap For 15Mm Dia. 277 End Cap For 20Mm Dia. 278 End Cap For 25Mm Dia. 279 End Cap For 32Mm Dia. 280 End Cap For 40Mm Dia. 281 End Cap For 50Mm Dia. 282 Ball Cock For 15Mm Dia. 283 Ball Cock For 12Mm Dia. 284 Ball Cock For 25Mm Dia. 285 Ball Cock For 32Mm Dia. 286 Ball Cock For 40Mm Dia. 287 Araldite Adhesive 288 Ball Valves For 50Mm Dia. 289 Male Adapter ( Brass Threads ) For 15Mm Dia. 290 Male Adapter ( Brass Threads ) For 20Mm Dia. 291 Male Adapter ( Brass Threads ) For 25Mm Dia. 292 Male Adapter ( Brass Threads ) For 32Mm Dia. 293 Male Adapter ( Brass Threads ) For 40Mm Dia. 294 Male Adapter ( Brass Threads ) For 50Mm Dia. 295 Male Adapter ( Plastic Threads ) For 15Mm Dia. 296 Male Adapter ( Plastic Threads ) For 20Mm Dia. 297 Male Adapter ( Plastic Threads ) For 25Mm Dia. 298 Male Adapter ( Plastic Threads ) For 32Mm Dia. 299 Male Adapter ( Plastic Threads ) For 40Mm Dia. 300 Male Adapter ( Plastic Threads ) For 50Mm Dia. 301 Female Adapter ( Brass Threads ) For 15Mm Dia. 302 Female Adapter ( Brass Threads ) For 20Mm Dia. 303 Female Adapter ( Brass Threads ) For 25Mm Dia. 304 Female Adapter ( Brass Threads ) For 32Mm Dia. 305 Female Adapter ( Brass Threads ) For 40Mm Dia. 306 Female Adapter ( Brass Threads ) For 50Mm Dia. 307 Female Adapter ( Plastic Threads ) For 15Mm Dia. 308 Female Adapter ( Plastic Threads ) For 20Mm Dia. 309 Female Adapter ( Plastic Threads ) For 25Mm Dia. 310 Union For 15Mm Dia. 311 Union For 20Mm Dia. 312 Union For 25Mm Dia. 313 Union For 32Mm Dia. 314 Union For 40Mm Dia. 315 Union For 50Mm Dia. 316 Cross For 15Mm Dia. 317 Cross For 20Mm Dia. 318 Step Over Bend 15Mm Dia. 319 Step Over Bend 20Mm Dia. 320 Tee Holder For 15Mm Dia. 321 Tee Holder For 32Mm Dia. 322 End Plug Threaded For 15Mm Dia. 323 R.C.C.Chamber Cover With Frame 90Cm*45Cm Heavy Duty 225Kg 324 R.C.C.Chamber Cover With Frame 90Cm*45Cm Medium Duty 140Kg 325 R.C.C.Chamber Cover With Frame 60Cm*45Cm Heavy Duty 160Kg 326 R.C.C.Chamber Cover With Frame 60Cm*45Cm Medium Duty 100Kg 327 I.S.I.Ferrul Connection15mm Dia. 328 I.S.I.Ferrul Connection 20Mm Dia. 329 I.S.I.Ferrul Connection 25Mm Dia. 330 I.S.I.Ferrul Connection 32Mm Dia. 331 I.S.I.Ferrul Connection 40Mm Dia. 332 I.S.I.Ferrul Connection 50Mm Dia. 333 Water Meter 15 Mm Diameter 334 Water Meter 20 Mm Diameter 335 Water Meter 25 Mm Diameter 336 Water Meter 40 Mm Diameter 337 Water Meter 50 Mm Diameter 338 Water Meter 80 Mm Diameter 339 Water Meter 100 Mm Diameter 340 Non Return Valve 40 Mm Diameter 341 Non Return Valve 50 Mm Diameter 342 Non Return Valve 80 Mm Diameter 343 Non Return Valve 100 Mm Diameter 344 Colour Wash Hand Basin 0.45 X 0.30 345 White Glaze Earth Sink 0.6 X 0.2 X 0.45 346 Clamp For G.I.Pipe 200Mm 347 Earopean Type Glazed W.C.Pan 68Cm 348 Earopean White Glazed Earthen Ware Closet Pan 349 P.V.C. Nahni Trap 350 P.V.C. Connector. 15 Mm Dia 351 Low Level Flushing Cistern 352 Upvc Sanitary Pipes All 20 Mm Dia. 353 Upvc Sanitary Pipes All 75 Mm Dia. 354 Bib Cock Stop Tap Brass Heavy 15Mm 355 Stainless Steel Sink Of Size 610 X 460 X 200 Mm Of Nirali Or Equivalent Make 356 Upvc Sanitary Pipes All 63 Mm Dia. 357 W.C.Pan Colour Glazed 57.50 Cm ( Orissa ) 358 Piller Cock Mixer & Angle Cock 359 Upvc Sanitary Pipes All 25 Mm Dia. 360 Upvc Sanitary Pipes All 15 Mm Dia. 361 Cement 362 Upvc Sanitary Pipes All 40 Mm Dia. 363 Upvc Sanitary Pipes All 50 Mm Dia. 364 Stainless Steel Sink Of Size 470 X 420 X 178 Mm Of Nirali Or Equivalent Make 365 Bib Cock Long Arm 366 Bottletrap Wash Basin 32 Mm Cromium Plated 367 Upvc Sanitary Pipes All 32 Mm Dia. 368 Hamp Rope 369 Bib Cock Cock Stop Tap Brass Heavy 15 Mm 370 Colour Wash Hand Basin 45*30Cm 371 Ultra 250 Mm. Dia. Upvc 90 Degree Junction Chamber Base With U Trap 372 Ultra 250 Mm.Dia. Upvccover & Frame 373 Upvc Blanking Plug 110 Mm 374 Upvc 90 Degree Bend 375 Ultra Shaft 250X470mm 376 Water Jet With Accessories 377 White Glazed Full Stall Urinal 378 Glass Plain 6Mm Thick 379 White Glazed Earthenware Squatting Plate ( Ladies Urinal ) 380 Autoclosing Pillar Cock Of Pressmatic Tap 381 Pvc Aqua Kraft Type Super Bib Tap 15 Mm 382 Pvc Aqua Kraft Type Super Two Way Bib Tap 15 Mm 383 Super Push Button Type Cock / Tap With Flange 15 Mm 384 Pvc Aqua Kraft Type Super Jet Spray 15 Mm 385 Pvc Aqua Kraft Type Super Right Angle Stop Tap 386 Pvc Aqua Kraft Type Super Pillar Tap 15 Mm 387 Fixing In Cc Bk Clamp, Battan 388 Wall Mounted European Type Glazed W.C.Pan 389 Super Wall Sink Type Tap With Flange 15 Mm 390 Two Way Bib Tap With Flange 391 Super Jet Spray With Flange 2 In 1 Faucet 1.50 Metre Long 392 Chloryphyriphos 393 Solvent 394 D.D.V.P. 395 Malathion 396 Pine Oil 397 S.S. Pipe 40 Mm Dia 398 Mild Steel 399 Barbed Wire 400 Concentina Coil Wire 401 M.S.Steel 402 Rcc Pole 403 Green Marble 404 Telephone Black Granite 405 Karva ( For Roof And Sides 10Kg Bundle ) 406 Tatti 407 Bamboo 25Mm Dia. 408 Lightening Conductor 409 Salt 410 Copper Tape Width 25Mm*3Mm Thick 411 Aluminium Strips 50 Mm X 3 Mm 412 Cripped Wire3 - 0 , 4 - 0 And 5 - 0 Wide 413 Welding Electrodes 414 Welded Mesh 75 X 75 Mm 415 Welded Mesh 150 X 150 Mm 416 Tarat 36 Width ( Gunny Cloth ) 417 Chain Link3 - 0 , 4 - 0 And 5 - 0 Wide 418 Bamboo 50Mm Dia. 419 Hold Fast For Steel Gate 420 Nut Boldts 12 Mm Dia. / Nails All Size 421 M.S. Pipe 40 Mm Dia 422 Welding Rod 423 Pvc Hand Rail Cover 424 Antitermite Liquid 425 Lock For Drawer / Cupboard 426 Glycel 427 Hing 428 Hot Lime 429 Ladder 430 Fine Tooth Chisel 431 Saw 432 Gloves 433 Tractor Breaker 434 Inforamtion Board 435 Labour Services Skilled Labour 436 Labour Services Unskilled Labour 437 Mechanic 438 Lorry Driver / Mixer Operator 439 Welder / Driller - Skilled 440 Polishman - Semi Skilled 441 Assistant Plumber - Skilled 442 Maistry Skilled / Supervisor / Mate 443 Vibrator Operator - Skilled 444 Skilled Labour 445 Labour For Excavation In Hard Rock ( Un Blast ) 446 Mazdoor - For Polishing 447 Bhisti ( Mixing / Curing ) - Semi Skilled 448 Mukadam - Semi Skilled 449 Helper Un Skilled 450 Mazdoor - Unskilled Heavy Male 451 Mazdoor - Unskilled Heavy Female 452 Laboratory Assistant 453 Labour For Tile Turning 454 Excavator - Unskilled Heavy 455 Breaker - Semi Skilled 456 Jack Hammer Operator 457 Electrician 458 Welder Skilled 459 Labour For Traffic Regulation 460 Watchman 461 Compressor Operator / Driver 462 Supervisor / Mate 463 Blacksmith ( 1St Class ) Welder / Plumber / Electrician. 464 Blaster ( Stone Cutter ) 465 Mali 466 Mazdoor / Dresser ( Semi Skilled ) 467 Mazdoor / Dresser Sinker B116 Skilled 468 Medical Officer 469 Operator ( Grouting ) 470 Para Medical Personnel 471 Mazdoor Unskilled Female ( Light ) 472 Junior Engineer 473 Surveyor 474 Autocad Operator 475 Attendent 476 Computer Typist 477 Tracer 478 Total Station Operator 479 Senior Engineer 480 Assistant 481 Operator / Fitter 482 Mazdoor Unskilled Light Male 483 Computer Operator 484 Survey Helper 485 Technician 486 Skilled Assistants-On The Site 487 Supervisor 488 Valuation Expert 489 Office Support Staff 490 Co-Ordinator 491 Senior Surveyor 492 Revenue Expert 493 Welder
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
47.
Defence #10566033 Price Bid
Tender For Additional / Alternator And Improvement To Smqs ( Phase- Iii ) At Afa Hyderabad; 1 Demolition Of Pcc In Roof Surfaces Including Existing Treatment And Demolition Of Pcc Under Sunken Floors Of Bathroom Including Floor Tiles Rooms Flooring Etc Of Any Description And In Any Position Not Otherwise Specifically Provided, Complete All As Specified And As Directed 2 Demolition Of Rcc Lintels, Chajja, Slab Cover, Beams Of Any Description And Height Upto 3M To 5M, Not Other Wise Specically Provided And In Simillar Works Complete All As Specified And As Directed 3 Removal Of Debris ( Aggregates Concrete, Rubble Etc Of Any Description ) Obatained From Demolition Including Loading And Unloading To A Distance Of 5.0 Km From The Starting Point And Deposited Where Directedcomplete All As Specified And As Directed.Note: One Load Equals To 0.62 Cum Of Aggregate / Concrete Debris / Rubble Etc. 4 M&L For Making Good With Cement Mortar 1:4 Under Cills Or Over Arches, Lintels And Bressummers, Including All Pinning When Necessary, At Any Height With Necessary Scafoldings Complete All As Specified And As Directed. 5 Demolition Of Brick / Stone Masonry Built In Cement Mortar Of Any Description, Complete All As Specified And As Directed 6 M&L For Pre-Cast Cement Concrete Block Masonry In ( 1:3:6 ) Type C1 ( Using 20Mm Graded Stone Aggregate ) With Solid Blocks Exc 10Cm In Width And Setting In Cement Mortar 1:4 In Walls / Parapet Walls Etcat Any Heightcomplete All As Specified And As Directed. 7 Taking Down Cement Plaster On Brick Or Stone Walls, Etc., Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc Complete All As Specifiedand Directed. 8 Cleaning The Roof Surfaces And Applying Oil Basedbitumen Primer @0.20 Kg Per Sqm, Providing4mm Thick App Modified Water Proofing Membrane Weight Not Less Than 4 Kg Per Sqm Reinforced With Non Woven Polyster Mat Weight Not Less 160 Gm Per Sqm Having Softening Point Not Less Than 140 Degree Centigrade, Longitudinal Tensile Strength Not Less Than 800N Per Sqcm Tearing Strenght Of 180N With Minimum Of 10 Cm Side Laps And 15 Cm End Laps By Application Of Torch, Applying A Coat Of Blown Grade Hot Bitumen Over The Membrane @ 1.20 Kg / Sqmas Per Manufacturer Instructionscomplete All As Specified And As Directed 9 M & L Cement Concrete ( 1:2:4 ) Typeb-1 Using ( 20Mm Graded Stone Aggregate ) In Haunching And Padding On Chajjas, Approchable / Unapprochable Areas Of Any Height, Complete All As Specified And As Directed 10 M&L For Applying One Coat Of Solar Reflective Bituminous Aluminium Paint Over Surface Of App Water Proofing Membrane @ 0.1 Kg / Sqm Complete All As Specified And As Directed. 11 Taking Up Or Downsteel Tubing And Connections Upto 25 Mm Bore For Refixing Or Removalcomplete All As Directed. 12 S&F 15 Mm Bore Steel Tubing Medium Grade Galvanised With All Fittings And Fixed Complete To Walls, Ceilings Or Laid In Floorscomplete All As Specified And As Directed. 13 S&F 20 Mm Bore Steel Tubing Medium Grade Galvanised With All Fittings And Fixed Complete To Walls, Ceilings Or Laid In Floors Complete All As Specified And As Directed. 14 Refixing Old 15 Mm Gi Tubing Obtained From Sl Item No 11Of Any Grade, Fixed With All Necessary Fittings / Connections In New Or Old Positions To Walls And Ceilings Or Laying In Floorscomplete All As Specified And As Directed. 15 Refixing Old 20 Mm Gi Tubing Obtained From Sl Item No 11 Of Any Grade, Fixed With All Necessary Fittings / Connections In New Or Old Positions To Walls And Ceilings Or Laying In Floors Etc Complete All As Specified And As Directed. 16 Cutting Chases For Concealed Water Tubing In Brick Or Stone Walls Or Concrete Surfaces And Making Good To Facings Where Required And Pointing In Cement Mortar 1:3, Cutting Not Exc 10 Cm Girthcomplete All As Specified And As Directed. 17 M&L For Pcc 1:2:4 Type B0 ( Using 12.5Mm Graded Stone Aggregate ) Average 25 Mm Thick With Water Proofing Compond As Per Manufacturers Instructions, Finished Even And Fair In Bottom Portion Of Sunken Floor Portion . Complete All As Specified And As Directed. Note : ( Wpc Will Be Measured & Paid Separately Under Relevant Item ) 18 M&L For Rendering 15Mm Thick In Cm 1 : 3 On Fair Faces Of Brick Or Concrete Surfaces Mixed With Water Proofing Compound As Per Manufacturers Instructions Finished Even And Smooth In Sunken Portion Withoutusing Extra Cement Etc Complete As Specified And As Directed. Note :Wpc Will Be Measured & Paid Separately Under Relevant Item 19 M&L For Applying A Uniform Coat Of Blown Grade Bitumen 85 / 25 @ 1.20 Kg Per Sqm Conforming To Is 702 Over A Coat Of Bituminous Primer @ 0.70 Kg Per Sqm And Over That Provision Of Water Proofing 3Mm Thick App Based Polymeric Membrane Of Weight Not Less Than 3 Kg Per Sqm Reinforced With Polyster Non Woven Fabric ( Wt Not Less Than 150 Gms / Sqm ) Laid On Prepared Surface By Forced Application As Per Manufacturers Instructions In Sunken Floorcomplete All As Specified And As Directed. 20 M&L For Pcc ( 1:5:10 ) Type E2 ( Using 40Mm Graded Stone Aggregate ) In Foundationfilling And Mass Concrete Complete As Specified And As Directed.. 21 Supply Only Intergral Water Proofing Compound As Per Manufacturers Instructions Complete All As Directed. 22 M&L For 40 Mm Dia Gi Pipe As Spouts In Sunken Floors, Medium Grade Complete All As Specified And As Directed 23 Dismantling Floor Hearth Or Existing Wall Tiling Incl Cement Mortar Bedding ( But Not Backing ) Including Removal Of Debris From The Site, Complete All As Specified And As Directed 24 M&L Joint Free Non Skid Ceramic Coloured Tiles Of Premium Quality 7 To 8 Mm Thick, ( Square / Rectangular ) , Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Colour Tiles, Laid Over And Including Screed Bed In Cm ( 1:6 ) 10 Mm Thick Complete All As Specified And Directed. 25 M&L Joint Free Glazed Coloured Ceramic Tiles Of Digital Quality In Vertical Surfaces Of Dados Skirting Etc450x300x7-8Mm Thick, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, Laid Over And Including Backing Coat / Renderingin Cm ( 1:4 ) 10 Mm Thick Complete All As Specified And Directed. ( Note: Colour Of Tile Will Be Finalized By Engr-In-Charge ) 26 M&L For Roughening Surfaces Of Old Concrete Floor By Picking, Hacking For Keys, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. For Preparation For Tilingand Spreading & Laying Of Cera Bond Chemical @ 6 Kg / Sqm For Fixing Floor Tiles Complete All As Specified And As Directed 27 M&L For Joint Free Glazed Colour Tiles Of Premium Quality 7 To 8 Mm Thick, ( Square / Rectangular ) , Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Colour Tiles, Laid Over And Including Screed Bed In Cm ( 1:6 ) , 10Mm Thick Complete All As Specified And Directed. 28 All As Per Item No 27 Above But In Vertical Surfaces Of Dados, Skirtings Etc Laid Over And Including Backing Coat / Rendering In Cm ( 1:4 ) 10Mm Thickcomplete All As Specified And As Directed. 29 S&F Of 20 Mm Thick Granite Work ( Table Rubbed And Polished ) Black Coloured, Cooking Platform And Like In Cement Mortar ( 1:4 ) Including Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite , Laid Over And Including Screed Bed 15 Mm Thick In Cm ( 1:6 ) Complete All As Specified And As Directed. 30 M&L Rounding To Edges Of Stone Slabs One Edge, In Cooking Plotforms Complete All As Specified And As Directed. 31 M & L For Rendering 15 Mm Thick In Cement Mortar 1:6On Fair Faces Of Brick Work Or Concrete Surfaces At Any Height With Neccesary Scafoldings, Finished Even Smooth Withoutusing Extra Cement. 32 M & L Forexternal Rendering 15 Mm Thick Cement Plaster In Two Layers 5Mm Thick In Cm 1:4 With Wpc / Liquid As Per Manufacturers Instruction Over 10 Mm Thick In Cm 1:6 On Fair Faces Of Brick Work Or Concrete Surfacesat Any Height With Neccesary Scafoldings, Finished Even Smooth Withoutusing Extra Cement Note :- ( Wpc Will Be Measured & Paid Separately Under Relevant Item ) 33 M & L For Rendering 10 Mm Thick In Cement Mortar 1:4 On Ceilings & Soffits Of Stair Case Waist Slab, Beam Bottom, Etc, Ofconcrete Surfacesat Any Height Including Neccesary Scafoldings, Finished Even And Smooth Without Using Extra Cement.All As Specified And As Directed. 34 Preparation Of Newly Plastered Internal Wall Surface And Applyingtwo Coats Of Distemper Oil Emulsion Over A Coat Of Alkali Resistant Priming Paint Over A Coat Of 3Mm Thick Wall Care Putty Complete All As Specified And As Directed 35 Preparing Newly Plastered External Wall Surfaces And Applying Two Coats Of Cement Based Paint Over A Coat Of Cement Primer, Complete All As Specified And As Directed. 36 Preparingnewly Plastered Surfaces Of Ceiling And Applying Three Coats White Washcomplete All As Specified And As Directed. 37 S&F In Repairs Of Vitreous China Wash Basin, White, Flat Back, Size 580X450mm Excluding Taps, Waste Chain And Plug And Porcelain Stopper But Including Brackets Complete All As Specified. 38 S&Fof Waste Coupling Of32 Mm Chromium Plated For Glazed Ware Basins With Long Screwed Shanks And Fly-Nuts Complete All As Specified And As Directed. 39 S&F Of Pillar Taps 15 Mm Dia, Cast Copper Alloy Long Nose, Chromium Platedfancy Typescrewed Down High Pressure, With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly-Nuts, Screwed For Iron Pipe Of 15 Mm Bore Complete All As Specified And As Directed. 40 S&F In Repair Of Bib Taps, Cp Fancy Typescrewed Down, Screwed For Iron Pipe Or For Brass Ferrule Andfixed To 15Mm Bore Pipecomplete All As Specified And As Directed 41 S&F In Repairs Of Stop Valves / Angle Cocks 15Mm Dia Cpfancy Typescreweddown High Pressure Screwed Both Ends For Iron Pipe Or For Unions, Of 15Mm Borecomplete All As Specified And As Directed. 42 S&F In Repairs Of Stop Valves ( Concealed Type ) 15Mm Dia Cpfancy Type Screweddown High Pressure Screwed Both Ends For Iron Pipe Or For Unions, Of 15Mm Bore Complete All As Specified And As Directed. 43 S&F In Repairs Of Vitreous China Squatting Pan, Orissa Pattern Of Size 580 X 440Mm, White With Integral Foot Rest Including Trap And Set In Concrete P Ors Trap As Per Site Requirements Including Making Good To Floor Complete All As Specified And Directed By Engr -In- Charge. 44 S&F In Repair 10 Lts Pvc Valveless, Syphonic Action Type, Flushing Cistern, Low Level, White, With Inlet, Ball Valve, Float And Handle Including Brackets For Fluslhing Cistern And Connections To Pipes Including Long Bends Complete All As Specified And As Directed. 45 S&F In Repairs Of Pvc Waste Pipe 32 Mm Bore, 900 Mm Longcomplete All As Specified And Directed By Engr -In- Charge. 46 Supply And Fix In Repairs, Pvc Connection 15 Mm Bore With Brass Cp Nuts, Of Length 450 Mm Complete All As Specified And As Directed. 47 S&F High Density Polyethylene Pipes 32Mm ( Hdpe ) With Collar Of Pressure Rating 6 Kgf / Cm2 Fixed Complete To Walls, Ceilings Or In Floors Etc.Complete All As Specified And As Directed. 48 S&F In Repairs For 15 Mm Dia Gun Metal Gate Valve With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed Complete All As Specified And As Directed. 49 S&F In Repairs For 20 Mm Dia Gun Metal Gate Valve With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed Complete All As Specified And As Directed. 50 S&F In Repairs For 125 Mm Cp Shower Rose, Fancy Type With Cp Arm, All As Specified And As Directed 51 S&F In Repair Of Stainless Steel Gratings 100Mm Dia, Hinge Or Openable Type, Fixed With Suitable Solvent Cement Etc Complete All As Specified And As Directed. 52 S&F Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long, Complete All As Specified And As Directed 53 Supply And Fix In Repairs Stainless Steel Sink With Drain Board Of Overall Size 915Mmx460mm Bowl Size 410Mmx330mmx160mm With Draining Board Made Out Of Stainless Steel 1 Mm Thick For Kitchenwith Plugs, Washers And Waste Pipe Including Cast Iron Cantilever Bracketsand Connecting To Union / Pipe Complete All As Specified And As Directed. 54 S & F In Repairs Brass Cp Fancy Tubular Towel Rail Of 20 Mm Dia, D Type 600 Mm Long Between Flanges, Including Brackets Complete All As Specified And As Directed. 55 S&F Pvc Cabinet Of Size 585X290x215, Complete All As Specified And As Directed. Cat No; Cc-252 Ofpearl Precision Products Or Equivalent In Prayag Or Equivalent Approved By Ge. 56 S&F Dish / Plate Display Rack Stainless Steel Hand Made - Wall Hangingof Cat No. P.336 Pf Prayag Or Equivalent ( Approximte Size 600Mm X 900Mm X 250Mm ) , Complete All As Specified And As Directed. 57 S&F 5Mm Thick Bevelled Edge Looking Mirror Of Size 600X450mm, Of Selected Quality, Including Fixing To Walls With Catch Nuts, Complete All As Specified And As Directed. 58 Taking Down Eaves Gutters And Rainwater Pipes ( Any Size Or Pattern ) , Including All Fittings, Heads, Shoes, Bends, Swan-Necks, Etc., Including Cleaning Or Refixing Or Removal To Store ( Measured Overall As Fixed Along The Centre Line Over Fitting And Accessories ) Complete All As Specified And As Directed. 59 S & F110 Mm Bore Pvc ( Swr ) Pipes Type BSingle Socketed, In Any Lengthfixed To Walls Or In Floors, Ceiling Etc Complete All As Specified And As Directed. 60 S & F75 Mm Bore Pvc ( Swr ) Pipestype B Single Socketed, In Any Length Fxed To Walls Or In Floors, Ceilingcomplete All As Specified And As Directed. 61 S & F 110 Mm Dia Bore Pvc ( Swr ) Bends, Any Radius With Oval Access Door, Complete All As Specified And As Directed. 62 S & F110 Mm Dia Bore Pvc ( Swr ) Bends, Any Radius, Complete All As Specified And As Directed. 63 S & F75 Mm Dia Bore Pvc ( Swr ) Bends, Any Radius With Oval Access Door, Complete All As Specified And As Directed. 64 S & F 110 Mm Bore Pvc ( Swr ) Vent Cowl, Complete All As Specified And As Directed. 65 S & F 110 Mm Bore Pvc ( Swr ) , Junction Single, ( Single T ) Equal Or Unequal With Access Door, Complete All As Specified And As Directed. 66 S&F In Repair Of Cast Iron Nahani Trap Of 75Mm Size With Cp Grating Including Jointing To Waste Pipe Fixed In Cement Concrete Type B1 ( 1:2:4 ) , Including Taking Down Existing Of Any Descriptioncomplete All As Specified. 67 S&F In Repair Of Cast Iron Floor Trap Of 100 Mm Size With Cp Grating Including Jointing To Waste Pipe Fixed In Cement Concrete Type B1 ( 1:2:4 ) , Including Taking Down Existing Of Any Descriptioncomplete All As Specified. 68 S & Fin Repairs Salt Glazed Stoneware Gully Trap, P Type 150X100mmmm, Including Taking Down Existing Of Any Descriptioncomplete All As Specified And As Directed. 69 Complete Removal Of The Existing Treatment On Walls And Applying Three Coats Of White Wash Including Preparation Of Surfaces Complete All As Specified And Directed By Engineer-In-Charge. 70 Complete Removal Of The Existing Treatment On Ceilings And Applying Two Coats Of White Wash Including Preparation Of Surfaces Complete All As Specified And Directed By Engineer-In-Charge. 71 M&L For Complete Removal Of The Existing Old Treatment On Walls And Applying Two Coats Of Distemper Oil Emulsion Over A Coat Of Alkali Resistant Primer Over 3Mm Thick Wall Care Putty, Including Preparation Of Surfaces Complete All As Specified And Directed By Engineer-In-Charge. 72 M&L For Complete Removal Of Existing Painting On Old Plastered Or Unplastered Surfaces On Wallsincluding Cornices By Applying Two Coats Of Cement Based Paint Over A Coat Of Cement Primerall As Specified And Directed By The Engineer-In-Charge. 73 M&L For Complete Removal Of Existing Painting On Old Plastered Or Concrete Facia / Cornice Surfaces And Applying Two Coat Of Santex Matt Painting Over A Coat Of Primertcomplete All As Directed. 74 M & L For Preparing Old Painted Wood And Wood Based Surfaces Of Any Description, Not Otherwise Described And Applying One Coat Of Synthetic Enamel Paint All As Specified And Directed By Engineer-In-Charge. 75 M & L For Preparing Old Painted Steel And Iron Surfaces Of Any Description, Not Otherwise Described Applying One Coat Of Synthetic Enamel Paint All As Specified And Directed By Engineer-In-Charge. 76 M & L For Preparing Old Painted Steel And Iron Surfaces, Plain Or Moulded, N Exc 10Cm Width Or Girth When Unconnected With Other Painting Or When Painted In A Different Tint, Not Otherwise Described Applying One Coat Of Synthetic Enamel Paint All As Specified And Directed By Engineer-In-Charge. 77 S&F Rotational Moulded Pvc Water Storage Tanks Of 500 Ltrs Capacity ( Cylindrical Vertical With Closed Top ) , Threelayered, Hoisted And Fixed In Positionincluding Out Let And Inlet Connections Including Dismantling Existing Water Tanks Of Capacity 500 Litres, All As Specified In Ssr Part–I And As Directed.. 78 S & F20 Mm Dia Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High-Density Plastic Ball Screwed For Iron Pipe ( Minimum Weigh 210 Gms ) Complete All As Specified And As Directed. 79 S&F Stainless Steel Tubular Curtain Rails 20Mm Diacompleteall As Specified And As Directed 80 S&F 20Mm Dia Fancy Type Brass Chromium Plated Curtain End Finials, Completeall As Specified And As Directed 81 S&F Stainless Steel Brackets Suitable For 20Mm Dia Curtain Rails, Etc Completeall As Specified And As Directed 82 Taking Down Chowkats Or Steel Window / Door Frames With Shutters ( Without Taking Off Shutters From Frames ) Not Exc 1.5 Sqm Each Complete All As Specified And As Directed. 83 Taking Down Chowkats Or Steel Window / Door Frames With Shutters ( Without Taking Off Shutters From Frames ) Exc 1.5 Sqm But Not Exc 4 Sqm Each Complete All As Specified And As Directed. 84 Taking Down Shutters Of Any Description Of Area Exc 1.0 Sqm But N Exc 2 Sqm Each Complete All As Specified And As Directed. 85 M & Lpcc 1:2:4 Type B1 Using 20 Mm Graded Aggregate For Bed Blocks For Securing Hold Fast And The Like Including Weathering, Sligtly Rounded Or Chamfered Angles And Throating, With Necessary Formwork Complete All As Specified And As Directed. 86 S & F Pressed Steel Frames 105X60mm Size Made With 1.25 Mm Thick Sheet , For Doors With Singlerebates Including Necessary Fixing Lugs, Lock Strick Plate, Etc, Complete All As Specified. 87 S & F Pressed Steel Frames 125X60mm Size Made With 1.25 Mm Thick Shee For Doors With Double Rebates Including Necessary Fixing Lugs, Lock Strick Plate, Etc, Complete All As Specified. 88 M&L For Pcc 1:3:6 Type C0 ( Using 12.5Mm Graded Stone Aggregate ) As In Filling Of Hollow Portion Of Pressed Steel Framecomplete All As Specied And As Direceted. 89 S & F 30Mm Thick Factory Made Flush Shutters, Solid Core Construction, With Block Board Core And Ply Wood Face Panels, Commercial Type On Both Sides Complete All As Specified And As Directed. 90 S & F35 Mm Thick Factory Made Second Class Hardwood Glazed / Gauzed And Skeleton Door Shutters , Open Rebated And Prepared To Receive Glass, Gauze, Mesh Etc With Sash Bars Divided Into Squares With Plain Chamfered Or Rounded Mitred Beads For Securing Glass Etc, Size Of Members Of Shutters As Specified In Ssr Part I Section 8, Clause 8.24 ( A ) And Fixed To Chowkats Complete All As Specified And As Directed. 91 S&F Powder Coated ( Thickness Not Less Than 50Micron ) Aluminium Three Track Sliding Windows Of Approximate Size 2000Mm X 1200Mm Made Out Of Anodised Aluminium Extruded Section Outer Frame With Gutter 92X45.5X1.50Mm And Shutter Section 40X18x1.50Mm Fully Glazed Including 5Mm Thick Sheet Glass, Rubber Gasket, Aluminium Beading, Suitable Fancy Type Handles, Locking Device, Rollers And All Other Required Hardware Fittings As Per Standard Engg. Practice, Complete All As Specified And Directed. 92 S&F Powder Coated ( Thickness Not Less Than 50Micron ) Aluminium Two Track Sliding Windows Of Approximate Size 115Mm X 1200Mm Made Out Of Anodised Aluminium Extruded Section Outer Frame With Gutter 61.85X45.5X1.50Mm And Shutter Section 40X18x1.50Mm Fully Glazed Including 5Mm Thick Sheet Glass, Rubber Gasket, Aluminium Beading, Suitable Fancy Type Handles, Locking Device, Rollers And All Other Required Hardware Fittings As Per Standard Engg. Practice, Complete All As Specified And Directed. 93 S&F Powder Coated ( Thickness Not Less Than 50Micron ) Aluminium Ventilators Of Approximate Size 600Mm X 800Mm, Top Hung Type Made Out Of Anodised Aluminium Extruded Section Of Thickness Not Less Than 1.50 Mm, Including 5 Mm Thick Tinted Glass, Suitable Aluminium Hinges, Aluminium Tower Bolts, Rubber Gasket, Aluminium Beading, Suitable Fancy Type Handles, Peg Stay And Including All Other Required Fittings As Per Standard Engg. Practice, Complete All As Specified And Directed. 94 S&F Powder Coated ( Thickness Not Less Than 50Micron ) Anodised Aluminium Frame For Windows And Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified And As Directed. 95 S&F Powder Coated ( Thickness Not Less Than 50Micron ) Anodised Aluminium Window Shutters, Side Hung Type Without Sash Bars, Aluminium Sections Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Aluminium Fittings Such As Peg Stays 150Mm Long ( 1 No. ) Hinge Type B-21 100Mm Long ( 2 No. ) Suitable Handle ( 1 No. ) Complete All As Specified And As Directed. 96 S&F 4.80Mm Thick Sheet Glass, Ordinary Quality, In Squares Exc 0.5 Sq. M Each Pane And Fixed To Aluminium Frames Or Shutters Of Any Description Complete All As Specified And Directed By Engr In Charge. 97 S&F Powder Coated ( Thickness Not Less Than 50Micron ) Aluminium Anodised Grill, Aperture N Exc 75 Mm , Size 6Mm X 4Mm Thick, Including 1 Mm Thick F Or H Section Channelsfixed With Steel Screws Complete All As Specified And Directed. 98 S&F Stainless Steel Wire Cloth, 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Wire Staples, Complete All As Specified And As Directed 99 S&F In Repair Ms Framed Work Such As In Grills And Framed Guard Bars For Windows / Ventilators With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes Etc And Similar Work Conforming To Fe 290, Gde E 165 Etc Complete All As Specified And As Directed 100 S&F Solid Pvc Frame ( Single Rebated ) Of Size 60Mm X 30Mm Made Out Ofsolid Pvc Foam With Homogeneous Fine Cellular Structure Having Smooth Outer Integral Skin With Suitable Metal Stiffner And Fixed With 100 X 8 Sheet Metal Csk Screws Complete All As Specified And As Shown On Drawing. ( Note:- Door Frame Shall Be Water Proof, Termite Proof, Elegant And Should Have Excellent Screws Holding Strength To Fix Hinges And Hold Doors Properly For A Long Life ) All As Specified And As Directed 101 S&F Factory Made Solid Pvc Profiled Panel Door Shutter 28Mm Thick With Integral Skin As Frame & 3Mm Thick High Pressure Compact Laminate On Both Side Of Approved Colour As Infill, With C Type Gi Or 40 X 20 X 19 Of Ms Pipe As Stiffner & Supplying & Fixing In Frame At Site As Per Specificationsall As Specified And As Directed 102 Taking Down Shutters Of Any Description Exc1 Sqm But N Exc 2 Sqm And Refixing The Same In Same Openings After Repairing Or Cutting Bottom As Per Site Requirement, Complete All As Specified And As Directed 103 S & Fbutt Hinges Of 100Mm Size, Medium Weight Cold Rolled Mild Steel And Fixedcomplete All As Specified And As Directed. 104 S & F Butt Hinges Of 100Mm Size, Extruded Aluminium Alloy With Galvanised Mild Steel Hinge Pin, Anodised, Type C-21 Complete All As Specified And As Directed. 105 S & F150mm Long Extruded Aluminium Alloy Handles, Cast Type Anodised Complete All As Specified And As Directed. 106 S & F Tower Bolt 150Mm Long, Extruded Aluminium Anodised Complete All As Specified And As Directed. 107 S & F 300Mm Long Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified And As Directed. 108 S & F 300Mm Long Mild Steel Ordinary Rat And Tail Rod Pattern Springs, Including Roller And Roller Plate Complete All As Specified And As Directed. 109 S&F50 Mm Size Butt Hinges, Medium Weight, Cold Rolled Mild Steel Complete All As Specified And As Directed. 110 S&F Second Class Hardwood Small Fittings Such As Brackets Of Any Type, Latch And Hinge Blocks, Shaped Door And Window Stops And The Like, Including All Necessary Labours; Articles N Exc 200 Cu. Cm Each Complete All As Specified And As Directed. 111 S&F 150Mm Long Floor Door Stopper Of Aluminium Alloy Body And Tongue, Anodised, With Hard Drawn Steel Spring. Fixed In Floor, Etc Complete All As Specified And As Directed 112 Running Welding In Repairs Of Thickness Of Metal N.Exc 6 Mmcomplete All As Specified And As Directed. 113 M & L Preparation Of New Or Previously Untreated Wooden Surfaces Of Any Description, Not Otherwise Described, Over 10 Cm Width Or Girth And Applying Two Coat Of Synthetic Enamel Paint ( Ordinary Tint ) Over A Coat Of Pink Primer, Complete All As Specified And Directed. 114 M & Lfor Preparation And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxideprimer On Newly Treated Steel Surfaces Of Any Description, Not Otherwise Described Over 10 Cm Width Or Girth Complete All As Specified And As Directed. 115 Demolition Of Cement Concrete In Ground Floors And Pavings N.Exc 15 Cm Thick Above Or Below Ground Level, Complete All As Specified And As Directed.. 116 M&L For Hardcore Of Gauge N Exc. 63 Mm Of Broken Stone Boulders, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed. 117 M&L 75 Mm Thick Cement Concrete In Sub Base To Pavings, Type D2 1:4:8 ( 40 Mm Graded Aggregate ) Complete All As Specified And As Directed 118 M&L 75 Mm Thick Cement Concrete, Type B-1, 1:2:4 ( 20Mm Graded Aggregate ) As In Pavings, Finished Even And Smoothwithout Using Extra Cement, Complete All As Specified And As Directed 119 Forming Construction Joint 30Mm Deep X 10Mm Wide Filled With Sealing Compound Of Grade A, Complete All As Specified And As Direceted. 120 M&L 75 Mm Thick Plain Cement Concrete 1:3:6 Type C2 Using 20Mm Graded Stone Aggregate As Inplinth Protection Etc., Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 121 Complete Removing Of Plants Including Roots By Dismantling / Cuttings Etc. Of Brick Work / Pcc / Rcc Including Necessary Scaffolding, Any Type, Any Location / Height ( I.E Roof, Parapet Walls Near Pipes Etc. ) And Applying Conc Acid After Removing Roots For Preventing The Regrowthing And Making Good The Disturbed Portion Using Pcc 1:2:4 Type B-O And Plaster In Cm 1:3 ( Size Of Disturbed Portion 150 X 150 X 150Mm ) Complete All As Specified & Directed By Engr- In -Charge. 122 M&L For Cleaning The Spalled Concrete Covers, Exposed Reinforced Corroded Bars With Water And Applying Two Coats Of Zinc Rich Anti Corrosive Coat On Bars And Then Replaster The Same With Cement Mortar 1:4 Of Average Thickness Of 40Mm, All Around With Wpc On Ceilings & Soffits Of Stair Case Waist Slab, Beams Ofconcrete Surfacesat Any Height With Neccesary Scafoldings, Finished Even And Smooth Without Using Extra Cement With Necessary Bonding Agent As Directed. Make: Build Core Chemicals, Stp Limited, Dr.Fixit Or Equivalent Approved By Ge. 123 M&L For Taking Down Existing Pointing Of Any Description Including Racking Out Joints, Hacking For Keys, Scrubbing Down With Water And Providing Raised Pointing To Old Stone Walls Surfaces Of Any Description, With Necessary Scaffoldings, By Using Cement Mortar 1:3 Complete All As Specified And As Directed. 124 M&L In Repair Second Class Hard-Wood In Scantlings, Clean Sawn, Fixed To Existing Chowkats Or To Walls, Complete All As Specified And As Directed 125 M&L For Second Class Hardwood Plain Fillets In Cub Boards, Shelves, Etc Exc 13 & N. Exc 25 Sq. Cm, Square, Rectangular Or Triangular In Section, Clean Sawn, Secured With Nails Or Brads, , Complete All As Specified And As Directed 126 M&L For Second Class Hardwood Plain Fillets In Cub Boards, Shelves, Etc Exc 6 & N Exc 13 Sq. Cm, Square, Rectangular Or Triangular In Section, Clean Sawn, Secured With Nails Or Brads, , Complete All As Specified And As Directed 127 M&L 18Mm Thick Marine Plywood Of First Grade , Fixed With Screws As In Cupboards, Sides Of Shelves, Partitions And In Simillar Works, All As Specified And As Directed.. 128 M&L 12Mm Thick Marine Plywood Of First Grade , Fixed With Screws As In Cupboards, Sides Of Shelves, Partitions And In Simillar Works, All As Specified And As Directed.. 129 M&L For 0.9 Mm Thick Decorative Laminated Sheet Type 1 Of Surface Finish Coloured Andpattern As Approved And Fixed Over Plywood With Approved Adhesive All As Specified. 130 M&L For External Teak Wood Lipping, 6Mm Thick, Fixed With Nails 19Mm Wide.Complete All As Specified And As Directed 131 S&F Brass Continuous ( Piano ) Hinges, Width Of Flap 30Mm Bright Finish Or Electrogalvanised, All As Specified And As Dierected. 132 Supply And Fix 100Mm Long Extruded Aluminium Alloy Handles, Cast Type Anodised Complete All As Specified And As Directed. 133 S&F In Repairs Of 100Mm Aluminium Anodised Hasp And Staple, Safty Type, With Hinge Pin Including Bolt To Hinge Plate And Fixed With Screws Etc Complete All As Specified And As Directed. 134 S&F Tower Bolt 100Mm Long, Extruded Aluminium Anodised Complete All As Specified And As Directed. 135 Excavating In Trenches N. Exc 1.5 M Width And N. Exc 1.5 M In Depth For Foundation Or Cesspits , Manholes , Pier Holes Etc N Exc 10 Sqm On Plan And N Exc 1.5 M In Depth Orgetting Out Soft / Loose Soil, Complete All As Specified And As Directed. 136 Demolition And Breaking Up Drain / Sewage Pipes 150 Mm Dia, ( Salt Glazed Ware, Ac Or Reinforced Concrete ) Set In Concrete Mortar, Complete All As Specified And Directed. 137 Cutting Holes Into Or Through Stone Wall Built In Cement Mortar Or Cement Lime Mortar And Walls Of Cement Concrete, Of Superficial Area Exc 400 Sq. Cm But N. Exc. 0.10 Sqm, Complete All As Specified And Directed. 138 Returning Filling In , Including Spreading , Levelling, Watering And Well Ramming In Layers N Exc 25 Cm In Soft / Loose Soil, Complete All As Specified And As Directed. 139 Removing Excavatedmaterialto A Distance Exc 1.50 Km But N Exc 5 Km Distance And Depositing Where Directed At A Level N.Exc 1.5Mm Abovethe Starting Pointcomplete All As Specified And As Directed. 140 M&L For Pcc 1:4:8, Type D-2 ( Using 40Mm Graded Stone Aggregate ) For Concrete Bed Of 10Cm Thick, To Drain Pipes Of 150 Mm Dia, Including Packing Under, And Hunching Against The Sides Of Pipes After They Are Laid And Tested, Complete All As Specified And As Directed. 141 M&L For 150 Mm Dia Pipe ( Grade ‘A’ Pipe ) Salt Glazed Stone Ware Drain Pipes Laid In Trenches And Jointed In Cm 1:3 Complete All As Specified And Directed. 142 Cutting Into Existing Manholes For Connecting New Drain Of 150 Mm Dia, Making Good To Pipes And Rendering, Cutting Out Existing Benching For And Forming Branch Channel ( 1 / 2 Round Or 3 / 4 Section ) In Cement Concrete 1:2:4 Type B-1, Smooth Finished, And Reforming Benching As Required, Complete All As Specified And As Directed. 143 M&Lproviding Precast Cement Concrete Type B1 1:2:4 ( 20 Mm Graded Aggregate ) In Landing, Cover Slabs Manholes, Chullah Hoods , Chajjas , Water Troughs , Shelves And Similar Articles With Plain Faces Set In Cement Mortar 1:4, Complete All As Specified And Directed. Note: Reinforcement Shall Be Measured Sepreatly 144 S&F Mild Steel Tmt Bar 6Mm To 8Mm Dia, Cut To Length , Bent To Shape As Required, Including Cranking, Bendingspirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia.Complete All As Specified And Directed. 145 Taking Down The Unserviceablepoint Wiring ( Light, Fan, Socket Or Power ) Complete With Fittings Such As Switches, Sockets Ceiling Roses Pendent Regulators, Sockets Etc Any Light Points And Making Good Disturbed Surfaces Of Walls And Floorscomplete All As Specified And Directed. 146 Taking Down Unserviceable Mcbs, Dbs, Main Switches Complete All As Specified And Directed. 147 Removing The Existing Metering Board Panel From Theexisting Wall After Removing The Existing Serviceable Electric Metersall As Specified And Directed.Note- Serviceable Electric Meter To Be Fixed In The New Panel Board. Item No- 148 148 Supply, Installation, Testing & Commissioning Of Indoor Type, Wall Mounted ( With Bolts And Nuts ) Meter Cabinet Of Size 1.5X1.2X0.2Mtr And Made Out Of 2Mm Thick Crca Ms Sheet With Front Door Having Glass Window For Viewing Kwh Meter And Other Doors Shall Be Opaque. All Door Sholud Have Neaprene Rubber Gasket And Locking Arrangements. The Cabinet Shall Be Painted Both Internally And Externally With Powder Coated Paint ( Shade : Ral 7032 Siemens Grey ) . The Cabinet Shall Be Dust And Vermin Proof With Degree Of Protection Ip 43. The Cabinet Shall Be Comprising With The Following Accessories:- 149 ( A ) Four Pole Mccb, 100Amps With Breaking Capacity Of 16Ka Having Adustable Thermal And Fixed Magnetic Release. ( B ) Aluminium Bus Bars For 3-Phase & Nuetral Of Current Carying Capacity Up To 200Amps Dully Mounted On Frp / Dmc Insulators And Necessary Drillingfor Connections And Duly Covered With Heat Shrinkable Pvc Sleeves Of Standard Colour Code. ( C ) Mcb Spn 32Amps, 10Ka - 5Nos. ( 04Nos For Meters, 01 For Spare ) ( D ) Mcb Spn 10Amps-01 ( 1 For Security Lights & Stair Case ) ( E ) Analog Type Timer Up To 10Amps Capacity Single Phase 230Voltage For Building Security Lights & Common Lights ( F ) Two Way Bakelite Connector With Nut, Bolts And Wahsers Suitable For Connecting The Outgoing Wires In The Cabinet - 6Nos ( G ) Fixing Of Old Serviceable Electric Meters Obtained From The Old Meter Panel Board. ( H ) Internal Wiring Of Meters / Mcb / Cable Connector Shall Be Carried Out With10sqmm Copper Conductor Unsheathed, Multistranded, Pvc Insulated, 1100Volts Grade, Single Core Cable Of Standard Colour Code For Phase & Neutral Including Necessary Lugs / Nuts / Bolts / Washers Etc. ( J ) Led Phase Indicating Lamps ( Ryb ) With Control Mcb ( Sp-2Amps ) - 3Nos.Taking Down Ceiling Fan / Exhaust Fan, Dismantling Blades And Removing Fan And Refixing Ceiling Fan / Exhaust Fan After Completion Of Re-Wiring And Connecting Up By Cleaning / Oiling Etc Including Provision Of 3Core Flexible Round Cable From Ceiling Rose Or Connector To Fan All As Directed. 150 Taking Down Ceiling Fan / Exhaust Fan, Dismantling Blades And Removing Fan And Refixing Ceiling Fan / Exhaust Fan After Completion Of Re-Wiring And Connecting Up By Cleaning / Oiling Etc Including Provision Of 3Core Flexible Round Cable From Ceiling Rose Or Connector To Fan All As Directed. 151 M&L For Point Wiring With 1.5 Sqmm Copper Conductor Unsheathed, Multistranded, Pvc Insulated, 1100Volts Grade, Single Core Cable With Earth Continuity Conductor Of 1.5 Sqmm Pvc Insulated Copper Conductor And Including Rigid Pvccondit Or Pvc Conduits / Casing Caping Of Suitable Size Withaccessories Fixed Orconsealed In Stone Walletc., Including Terminal Boxes Made Out Of 1.2Mm Thick Ms Sheet For Switches, Fan Regulators Socket Outlet Etc Along-With 3Mm Thick Top Laminated Bakelite Sheet For Housing Switches, Sockets, Regulators Etcfor One Light Point Controlled By One One Way 5 Amps Switch 152 Note ( I ) : Necessary Pvc Rigid Junction Boxes For Identifying Junction As Required On Site / Directed By Engr-In-Charge For Point Wiring Work With Pvc Dummy Plates Shall Deemed To Be Included In The Quoted Rate. 153 ( Ii ) Same Size Wire Shall Be Used For Phase, Neutral & Earth Conductor 154 ( Iii ) The Wiring Shall Be Done Strictly By Following Proper Colour Coding Using Red, Yellow And Blue For Phase, Black For Neutral And Green For Earth Leads. 155 All As Per Item No 151 Above But One Light Point Controlled By Two, Two Way 5 Amps Switch 156 All As Per Item No151above But One Ceiling Fan / Exhaust Fan Point Controlled By One 5 Amps Switch 157 All As Per Item No 151Above But Socket 5 Amp On Independent Board. 158 All As Per Item No 151 Above But One 3 / 5 Pin Socket Out Let5 Amp On Same Board With Other Switches. 159 All As Per Item No 151 Above But One Bell / Buzzer Controlled By One 5 Amps Push Button Switch. 160 All As Per Item No 151 Above Butwiring With 2.5 Sq Mm Copper Cable With 2.5 Sq Mm For One Earth Continuitycablefor 6 Pin 15 Amps Socket Out Controlled By 15 Amps Switch.Complete All As Specified And As Directed. 161 Supply And Fixswitch Socket Combination 5 A / 15 Amps 5 In 1, Multipurpose Flush Type, Isi Markedcomplete All As Specified And As Directed. 162 Supply And Fixswitch Socket Combination 2 In 1, 5 Pin 5 Amps, Multipurpose Flush Type, Isi Markedcomplete All As Specified And As Directed. 163 Supply & Fixing Socket Outlet 3 / 5 Pin 5 Amp Flush Type Isi Markedcomplete All As Specified And As Directed. 164 Supply And Fixswitch Piano Flush Type, Single Pole, One Way, 5 Amps, 230 Volts, Isi Markedcomplete All As Specified And As Directed. 165 Supply And Fixswitch Piano Flush Type, Single Pole, Two Way, 5 Amps, 230 Volts, Isi Marked Complete.Isi Markedcomplete All As Specified And As Directed. 166 Supply And Fixbell Push , 5 Amps, 230 Volts, Isi Markedcomplete All As Specified And As Directed. 167 S&F Ceiling Rose, Three Terminal, Pvc / Polycarbonate, Isolated Body, Isi Markedcomplete All As Specified And As Directed. 168 Supply And Fix Bell Multi Music Type Ac 230 V Complete All As Specified And As Directed. 169 S & F Stepped Type Electronic Fan Regulator Flush Type All As Specified And As Directed. 170 Supply & Fixing Angle Holder / Batten Holder Insulated Complete All As Specified And As Directed. 171 S&F Surface Mounting / Wall Mounted Led Tube Light Fitting 1X18 To 20Wattshigh Efficiency, Anti Glare, Maintenance Free Operation Including Led Driver And Mounting Arrangements, All Accessories Internally Pre-Wired, Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable White Colour With Suitable Size All As Specified And Directed By Engineer-In-Charge. 172 S&F Surface Mounting / Wall Mounted Led Tube Light Fitting 1X10wattshigh Efficiency, Anti Glare, Maintenance Free Operation Including Led Driver And Mounting Arrangements, All Accessories Internally Pre-Wired, Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable White Colour With Suitable Size All As Specified And Directed By Engineer-In-Charge. 173 Supply & Fixing 1X10w Led Bulkhead Fitting Housing With High Pressure Die Cast Alluminium, Poly Carbonate Front Diffuser Cover Including Led Driver, Lamp Andall Accessories Internally Pre-Wired, Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable White Colour With Suitable Size Including Taking Out Old Unserviceable One Complete All As Specified And Directed By Engineer-In-Charge. 174 Supply And Fix Gi Pipe Light Grade Brackets 40 Mm Dia, 1.5 M Long Bent To Shape As Required And Fixed With Suitable Size Of 02 Nos Ms Clamps Made Out Of Flat 25Mm X 4Mm Duly Drilled With Nuts, Bolts, Washers Etc., To Poles / Walls Complete All As Directed. 175 Supply And Fixled Street Light Fitting 1 X 30 Watt Led Pressure Die Cast Aluminum Housing Heat Resistant Toughened Glass With Frame , Ip - 66 Protection, Uniform Distribution Make:-Cromptoncat Part No:- Lsto-30-Cdl Or Equvalent ( Suitable For 40 Mm Outer Dia G I Pipe ) And Connecting Up .Complete All As Specified And As Directed. 176 M&L For Sub Main Wiring Pvc Insulated Cable 2 Single Core 10Sq Mm 1100 V Grade ( Nominal Area ) Single Core Pvc Insulated Unsheathed Cable Multi-Stranded Copper Conductor Drawn Through And Including Medium Grade, Rigid Non-Metallic Pvc Conduit / Casing & Capping Of Suitable Size With All Necessary Fittings, Concealed In Walls / Roof / Floor Duly Earthed With One Run Of Single Core Cable Of Same Size But Green In Colour As Continuous Earthing Wire And Connecting To Common Earth Dolly Complete And After Taking Out The Existing Sub-Main Wiringetc. Complete All As Specified And Directed By Engineer-In-Charge. 177 Note ( I ) : Necessary Pvc Rigid Junction Boxes For Identifying Junction As Required On Site / Directed By Engr-In-Charge For Point Wiring Work With Pvc Dummy Plates Shall Deemed To Be Included In The Quoted Rate. 178 ( Ii ) Three Runs Of Cable And One Run Of Conduit With Necessary Accessories Will Be Measured As One Unit Length. 179 ( Iii ) The Wiring Shall Be Done Strictly By Following Proper Colour Coding Using Red, Yellow And Blue For Phase, Black For Neutral And Green For Earth Leads. 180 M&L For Sub Main Wiring Pvc Insulated Cable 2 Single Core 6Sq Mm 1100 V Grade ( Nominal Area ) Single Core Pvc Insulated Unsheathed Cable Multi-Stranded Copper Conductor Drawn Through And Including Medium Grade, Rigid Non-Metallic Pvc Conduit / Casing & Capping Of Suitable Size With All Necessary Fittings, Concealed In Walls / Roof / Floor Duly Earthed With One Run Of Single Core Cable Of Same Size But Green In Colour As Continuous Earthing Wire And Connecting To Common Earth Dolly Complete And After Taking Out The Existing Sub-Main Wiringetc. Complete All As Specified And Directed By Engineer-In-Charge. 181 Note ( I ) : Necessary Pvc Rigid Junction Boxes For Identifying Junction As Required On Site / Directed By Engr-In-Charge For Point Wiring Work With Pvc Dummy Plates Shall Deemed To Be Included In The Quoted Rate. 182 ( Ii ) Three Runs Of Cable And One Run Of Conduit With Necessary Accessories Will Be Measured As One Unit Length. 183 ( Iii ) The Wiring Shall Be Done Strictly By Following Proper Colour Coding Using Red, Yellow And Blue For Phase, Black For Neutral And Green For Earth Leads. 184 M&L For Sub Main Wiring With Two Runs Of 1.5Sq Mm 1100 V Grade ( Nominal Area ) Single Core Pvc Insulated Unsheathed Cable Multi-Stranded Copper Conductor Drawn Through Medium Grade, Rigid Non-Metallic Pvc Conduit / Casing & Caping ( As Per Site Requirement ) Of Suitable Sizewith All Necessary Fittings, Surface In Walls / Roof / Floor Duly Earthed With One Run Of Single Core Cable Of Same Size But Green In Colour As Continuous Earthing Wire And Connecting To Common Earth Dolly Complete All As Specified And Directed By Engineer-In-Charge. ( For Bldg Security Light ) 185 Note:- ( I ) Necessary Pvc Dummy Plates & Pvc Rigid Junction Boxes For Identifying Junction As Required On Site / Directed By Engr-In-Charge Shall Deemed To Be Included In The Quoted Rate. 186 ( Ii ) The Wiring Shall Be Done Strictly By Following Proper Colour Coding Using Red, Yellow And Blue For Phase, Black For Neutral And Green For Earth Leads. 187 ( Iii ) Three Runs Of Cable And One Run Of Pvc Conduit / Casing Caping Will Be Measured As One Uint. 188 Supply And Fix Sheet Metal Enclosure Single Door Mcb Db2 Way With 240V Rated Without Busbar Complete All As Specified And Directed By Engineer-In-Charge. 189 Supply And Fix Sheet Metal Enclosure Double Door Mcb Db Spn 8 Way With 100 A Rated Bus Bar & Neutral Link Complete All As Specified And Directed By Engineer-In-Charge. 190 S & F Mcb Spn 6 To 32A, 10 Ka Rupturing Capacity Complete All As Specified And Directed By Engineer-In-Charge. 191 S & F Mcb Sp 6 To 32A 10 Ka Rupturing Capacity Complete All As Specified And Directed By Engineer-In-Charge. 192 M&L For Earthing Complete With Gi Earth Plate Electrode Of Size 600X600x6.6 Mm Thick Buried Directly In Ground With Earth Pit Not Less Than 2.25 Meter Deep Below Ground Level With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level Connected To Gi Wire 4 Mm Dia Earth Lead By Means Of Nuts, Bolts, Check Nuts, Washers Of Galvanised Iron As Steel, Protected By Galvanized Iron Pipe 40Mm Bore ( Medium Grade ) Allas Directed Including Cement Concrete ( 1:3:6 ) Type C-1 Earth Pit With Precast Rcc ( 1:1.5:3 ) Type A-1 Cover Slab Of Size 42 X 42 X10cm Thick Reinforced With 8Mm Dia Tmt Bars @ 15 Cm C / C Both Ways With 10Mm Dia Mild Steel Round Bar Of 30 Cm Long, Bent To Shape As Lifting Handle, Funnel, Wire Mesh, 20 Mm Bore Galvanized Iron Pipe ( Medium Grade ) For Watering, Earth Testing Point, Charcoal Or Coke And Salt In Alternate Layers With Necessary Earth Work In Soft / Loose Soil Complete All As Shown In Electrical Plate No 3 Of Ssr Part I Including Testing On Completion All Complete As Specified And Directed After Taking Down Old Earthing. ( Gi Wire Upto 7.5M Including Testing Consider In This Item ) . 193 Note: ( I ) Cost Of Gi Earth Wire And Gi Protection Pipe Upto 7.5Mtr Length Shall Be Deemed To Be Included In The Rate Quoted For This Item. ( Ii ) The Unit Rate Shall Also Includes For Wire Mesh, Funnel, Excavation, Returninng & Filling, Pcc Chamber Pit, Rcc Cover & Test Point ( Iii ) Pcc Pit Shall Be Provided At Least 500Mm Away From The Earth Pit And Not Just On The Earth Pit 194 M & L Sand Covering / Cushioning For Underground Cable Protection All As Specified In Ssr Part- I And Punning Down Complete All As Specified And Directed By Engineer-In-Charge.Note: Punned Thickness Shall Be Measured 195 M&Lfor Burntbricks Sub ClassB Laid Perpendicularover & Cushioning For Cable Protectioncomplete All As Specified & Directed At Site By The Engr- In Charge. 196 Supply And Lay Lt Ug Cable, Xlpe Insulated Armoured, Heavy Dutyaluminium Conductor Multistranded, 1100Volts Grade, Of 16Sqmm X 4Core Cross Sectional Area Laid In Trenches / Fixing On Walls / Poles Or Passing Through Gi Pipe Including Connecting Up With Suaitable Lugs, Nuts And Bolts Wherever Required And Testing Complete All As Specified. 197 Supply And Fix Cable Gland Double Compression Type, Weather Proof For 4Core 16Sqmm Armoured Cable Complete All As Specifed And Directed By Enginner-In-Charge. 198 Taking Out Old Unserviceable Cable, Lt 1100V 10Sqmm 2 Core From The Trench After Taking Necessary Shutdown From The Oh Lt Supply And Making Good The Disturbed Surfaces As Per Existing Complete All As Specified And As Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
48.
Public Administrative Department #10554880 Price Bid
Construction of tube well pumping plant & Pump House for 300*200 mm tubewell at ward 17 kashiram avash yojna sikarpur road - Drilling of borehole for Tubewell contruction by RCRig Machine including transportation, erection,dismantling of Rig and assoiated T & P complete inall respect including required all material, labouretc. 2 Transportation, Erection and Dismantling of Rig Machine 3 Drilling of 675 mm size bore from GL to 45 BGL 4 Drilling of 600mm size bore from 45M BGL to 100MBGL 5 Drilling of 600mm size bore from 100M BGL to 150MBGL 6 Tubewell Assembly M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect 7 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. 8 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. 9 Supply of pea gravel 10 Logging of bore hole by departmental / approved electric logger 11 Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect 12 Lowering of 300mm dia pipe from GL to 42m deep BGL. 13 Lowering of 200 mm dia pipe from 42 to 100mdeep BGL 14 Lowering of 200 mm dia pipe from 100 to 135m deep BGL 15 Development of Tubewell by compressor 16 Transportation, Installation and Dismantling of 250 PSI Compressor 17 Development of Tubewell by 600 PSI Capacity Air compressor 18 Development of Tubewell by O.P. unit 19 Transportation, Installation and Dismantling of 1 Cusec O.P. Unit & Yield Test 20 Development of Tubewell by 600 PSI Capacity Air compressor 21 Chemical and Bacterological test of water sample from depaprtmental/ approved lab 22 Water arrangement for construction ofT.W 23 Provision of temporary fencing baricating at T.W site 24 Site Clearance after completion of T.W & cutting,welding of well cap after development and earth filling in water pits 25 PUMPING PLANT FOR 300*200 MM TUBEWELL 26 Switch gear panel for 40 HP along with cubical panel, star delta automatic starter , power wring and earthing material,Earthing,Painting ,Toolset, r,Wiring of pumphouse internal & external, ChainpulleyBlock and all Pumping Plant accessories with nut bolts andRubber packing etc.complete in all respect with all requiredmaterial, T&P labour etc., dozzing plant. complete in all respect 27 submersible pump set of 1500 LPM dishcharge 45mtr. Headcompleate with 40Hp electric motor 28 Motor operated Actuators with Sluice valve of size 150 mm. at Main line and Bye-pass line as well. 29 3 Mtr. long heavy duty size 150mm dia column pipe same as above spare.( 01 No. set has 02 nos. column pipes 30 Supply & Fixing of riflex valve (6) C.I including all competion of work. 31 Supply and Laying 150mm (6) M.S pipe with lowering, flenge, paking seat etc. including all completion of work 32 Supply and Laying submersibble cable-10mm2 , 3 core 33 Cost for shifting and subsequent erection of scada system with fixing offlow meter,power wiringetc. with connected material from old tubewell to location of rebore tubewell complete 34 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank 35 Excavation in foundation in ordinary soil (loam, clay or sand) including lift up to 1.50m & lead up to 50m, refilling, watering and ramming of evcavated earth into the trenches or space betwwen the building and sides of foundation trenches or into the plinth and disposal of surplus earth up to the distance of 50m from the center of the foundation trenches. 36 Concretewith40mmgauge brick ballast,local sand and cement in proportion in 12:6:1 in foundation including supply of all material, labour T&P etc. required for proper completion of work. 37 Ist.Classbrickworkin1:4cement andlocalmortarinfoundationandplinth including supply of all material,labour T & P etc. required for proper completion of work. 38 RCC Work with cement, approved coarse sand and 2 cm gauge approved stone grit in proportions of 1:1.5:3 in Beam S.I. No. 285 (a) 39 Ist.Classbrickworkin1:4cement andlocalmortarinfoundationandplinth including supply of all material,labour T & P etc. required for proper completion of work. 40 Supply and fixing of M.S. angle iron chaukhats of 40mmx40mmx5mm with M.S. sheet door shutter including simple moulding straightg work as in chaukhats and also supply of all material, labour T&P etc. required for proper completion of work. 41 R.C.C. work with cement, coarse sand and 20mm gauge approved stone ballast in proportion of 1:1.5:3 in sunshed and lintel on doors and windows excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50mm thick binding wire and the cost of binding wire and including necessary centering and shuttering supply of all material, labour T &P etc. required for proper completion of work. 42 M. S. or iron work in plain work such as R.C.C.or R.B. work (when not included in over all rates) brought to required shape as necessary including bending for proper completion of the work including supply of steel and its wastage. 43 12mm thick plaster with cement and local sand mortar I:6 over brick work minimum thickness not to be less than 10mm including supply of all material, labour T&P etc. required for proper completion of work. 44 Supply and fixing of 50mm wide and 4mm thick glass strips in panels including supply of all material, labour T&P etc. required for proper completion of work. 45 50mm thick 1:1.5:3 plain cement concrete floor with cement coarse sand and 20mm gauge stone ballast laid in pannels finished with 3mm floating coat of neat cement or cement and marble dust in ratio 1:5 as specified and removing any overlaping or mortar at the joints of panels if any and giving them uniform finish including 46 Painting or varnishingnew work or new wood work in smallareas with one priming coat and two coat of approved quality paint or varnish including supply of all material, labour T&P etc. required for proper completion of work. 47 Distempering (two coat) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N, Shalimar, Asian Paint after thoroughly brushing the surface free from mortar dropping and other foreign matters and also sand papered smooth including supply of all materials, labour, Tools & plants etc. required for proper completion of the work.. 48 Finishing walls with water proof cement paint of approved make (Apex painting) and quality on new work with two coats to give an even shade including supply of all material, labour T&P etc required for proper completion of work. 49 Supply and fixing of Girder of 250 mmx125mmsize over the pump house including its painting with approved quality paint and also one priming coat. 50 Sand filling in plinth in pump house and chloronating room including supply of all material, labour T&P etc. required for proper completion of work. 51 Supply cutting and dressing with size and fixing V-Notch of size 90x90cm in the by pass chamber including prepration of by pass chamber as per direction of E/I including supply of all material, labour T&P etc. required for proper completion of work. 52 Mud Faska on R.B. or R.C.C. Roof with 100 mm thick clay layer on roof and laying of tiles and jointing them with cement and sand mortar including supply of all material, labour T&P etc. complete. 53 Supply & Fix 100 mm dia P.V.C. down pipes complete with rose & bend and gratings with M.S. clamps 25X3mm fixed on walls & supply of 150mm long, 6mm dia nails complete. 54 Earth filling in plinth including cartage up to site of work complete. 55 Supply and fixing of inoguration black granite stone padestal i/c grooving matter, b/w, plaster, painting etc all complete work
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
49.
Health and Family Welfare #10546188 Price Bid
Ct Scanner 16 Slice With Flat Table Top Couch(Ct Simulator) Ct Scanner 16 Slice With Flat Table Top Couch(Ct Simulator) , Ct Scanner 16 Slice With Flat Table Top Couch As Per The Specification Except The Following , Additional Work Station , Dry Imager , Pressure Injector With Syringes , Full System Ups , Lead Glass , Light Weight Vinyl Lead Apron With Thyroid Shield , Gonad Shield , Music And Patient Address System With Speakers , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion):Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos /Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System (Cup Lock Type ) On The Exterior Side Of Building/Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, (2) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size). , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S (Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand)Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976/2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili/ Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977/2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978/2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979/2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer(Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980/2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C/C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms/Sqm (Both Side Inclusive), Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, ,Made Of G.I Sheet Having Galvanizing Of 100 Gms/ Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections (Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg/ Sq. Cm, Bending Strength 100 Kg/Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg/Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer (Fittings To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , 10.16.3 Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981/2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982/2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983/2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500/31000/40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I/C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878/2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf/Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf/ Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf/Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf/Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf/Cm2 , Od31984/2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized/Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness,Fixed To The Shutter Styles By Means Of Plastic/Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge( For W.C. And Bathroom Door Shutter). , Od31985/2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986/2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987/2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989/2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990/2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991/2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board /Any Other False Ceiling. The Rate Including All Labour Charges ,Material Charges Ect Complete. , Od33559/2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth(Bio-Active Fabric Washable Germfree-Suitable For Icu Room) Curtain System With Maximum Curtain Cloth Height 230Cm (Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval) Stitching With Stifiner Tape,Pleats,Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging/Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup ,All Leads And Lifts Including All Labour Charges Etc. Complete.(Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet)/Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length (App. Length 1.10M) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C/C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level ,Sealing All Gaps In False Ceiling Due To Hanging Supports ,All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560/2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored(30Mm) Lead(2Mm) Lined Flush Door Side Hung Two Rebated Shutters With Plywood(6Mm) & Laminated (1Mm) On Both Sides And All Accessories ( Ss Hinges (4 Nos), Tower Bolt , Ss Handles Etc..) , Lead Lined Door Frames: Lead(2Mm) Lined Flush Door Side Hung Single Shutter With Plywood(6Mm) &Laminated (1Mm) On Both Sides And All Accessories(Lead Sheet Should Overlap Door Frame & Wall )Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood /Jack Wood (Frame Size 12 Cm X 8 Cm) , Wood Frame For Fixing Lead Glass (Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard (Godrej) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled (Looped) Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor,Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module (200Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module (125Mmx125mm) , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers/ Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300/305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va/C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way (8+18) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8 + 18) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface/ Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/ Rccb/Isolator)2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, (Three Phaseand Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35/36 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 70 Sq. Mm (38Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 95 Sq. Mm (45Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 185 Sq. Mm (57Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 240 Sq. Mm (62Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm (25Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm (35Mm) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.65 Mm Copper Conductor (12 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm (12 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm (10 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm (8 Swg) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/ Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required (For Horizontal Run) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/ Terminating With Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W (Max), 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required (Philips, Wipro Or Similar Superior Make) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes (Make: M/S Almonard/ Crompton/Bajaj Or Equivalent) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan/ Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable (Size As Per The Requirement Of Ac Manufacturer) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit(Powder Coated) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw/Hr With Rotary/Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw/Hr With Rotary /Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables/Wires(Havells/Rr Kabel/V-Guard Frls Wires) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg/Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts/Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning (Sitc) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required , Supply And Providing Copper Earth Bus In The Panel Board , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos %Icu= 25Ka) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Suitable De- Humidifier Units : Extraction At Least 35 Litres/Day, Compresor : Rotary, Air Flow : At Least 220M3/Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Buy Back Offer Of Old Ct Simulator Available At Mch Kohikode , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp Digital Multifunction Meter To Read V,A.Hz,Pf,Kwh Surge Protection Device (Type1+2) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply, Installation, Testing And Commissioning (Sitc) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required (Not Taken For Evaluation) , Ct Fluoroscopy (Not Taken For Evaluation) , Branded Personal Computer With Printer (Not Taken For Evaluation) , Led View Box 3 Film (Not Taken For Evaluation) , Apple Osrix Workstation (Not Taken For Evaluation) , Neuro Package Including Neuro Dsa & Neuro Perfusion (Not Taken For Evaluation) , Spectral Package Including Twin Spiral Spectral Viewing, Dual Energy And Calculi Characterization (Not Taken For Evaluation)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
50.
Metro Rail #10545528 Price Bid
tender for Maintenance Contract Of Civil Works Addition Alteration modification Repair Maintenance Of Various Stations Rss Buildings Between Mansarovar To Badi Chaupar And Any Other Metro Railway Premises Of Jaipur Metro Rail Corporation At Jaipur As Per Bid Documents - Maintenance Contract Of Civil Works : Addition, Alteration/Modification, Repair & Maintenance Of Various Stations & RSS Buildings Between Mansarovar To Badi Chaupar And any Other Metro Railway Premises Of Jaipur Metro Rail Corporation At Jaipur Sl. No. Item Description 1 6mm Toughened Glass in existing frame: Providing and Fixing 6mm thick clear float toughened glass in aluminium door, window, ventilator, shutters and partitions etc. with PVC/ Neoprene gasket etc complete as per architectural drawings and the directions of Engineer-In-Charge. 2 Providing and fixing in position Toughned glass of 12mm thickness all complete including minor cutouts/openings as per the direction of Engineer-in-charge. 3 Providing & Fixing of Floor Spring, Patch (Hydraulic) (OZONE MAKE) for Glass Door Assembly/Unit complete as per Directions of Engineer-In-Charge. 4 Providing and fixing tactiles 12mm thick yellow directional vitrified porcelain Granite tactiles (Australian made) laid on floor with laticrete 111 crete filler powder mixed with laticrete 73 latex admix and applied to a minimum thickness of 4.5 mm. The mixing ratio shall be as follows : 20 Kg Bag (Laticrete111):5.5 Ltr (Laticrete 73) spacer of 3 mm shall be used between the tiles and joints filled using laticrete Latapoxy SP-100 epoxy grout in Inca gold colour. The joint depth shall be 6 mm. Laticrete product shall be procured by Laticrete India Pvt Ltd/Laticrete International Inc (Tiles for blind people - directional tiles as installed in JMRC station) 5 Repair of defective rolling shutter with using any material required for bend repair,tightening of spring,bolt & screw and welding by welder as a complete job as per direction of Engineer In charge.(Upto 12 Sqm in area)(This item includes cost of necessary scaffolding,all lead & lift and consumable i.e welding electrodes of required specifications as per site requirements) 6 Extra For Reparing of Rolling Shutter having size more than 12 sqm in area 7 Skilled labour for sewerage chamber/pipe line cleaning/clearing choking with all T&P including all required machinery. 8 ROCA meridian-N soft close seat cover white 9 Providing ofaccess raised floor of light grade (15 KN/m2) UDL panels manufactured from pressed formed corrosion resistant galvanised steel with total overwrap of one piece top, sides and bottom flange encapsulating high performance chip board case stiched and with a panel to cater in the size 600*600*31mm with new panels of same specifications complete in all respects. the acess floor should be able to take a point load of 2.5 KN over 25 mm sq. and UDL of 15 KN/sqm. The panel shall be finished with high abrasion , anti-static HPL of formica colour Y606 having fire rating as per BS 476 clause 5, 6 & 7. 10 Supplying and fixing rolling shutters of approved make, made of 80 x 0.8mm color coated G.I Laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets of M.S, side guides of G.I and arrangements for inside and outside locking with push and pull operation complete including cost of sring hooks, providing and fixing necessary 45.0 cm. long wire springs grade No-02 including dismantling of existing rolling shutter as per the directions of Engineer-In-Charge. 11 Colour Coated G.I Top Cover 0.5mm thick for rolling shutters as per instructions of Engineer-In-Charge. 12 Providing and fixingpink dholpur sand stone work of size as specified below, of approved colour/patternat all levels for wall lining/Columns (veneer work) by mechanical arrangement with S.S.Cramp/ brackets,.Anchor bolts,5mm vertical S.S. of approved make. Inserts as per drawings and specifications. The cost for making necessary grooves in the stone to accommodate the vertical inserts, grooves all-around stone pieces, making 10mm deep rebate for tile inlay, chamfering of corner edges and polishing are included. 13 pink dholpur sand stonesize (1600-1800)x600x25mm minimum thick 14 Providing and laying 30mm thick FLAMED Sadarhalli Grey Granite Stone flooring in treads and landings (including bull nosing, rounding the nose and making groove) of stepsof approved colour, size and pattern, (sample of granite stone shall be approved by Engineer-in-charge) over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with neat cement slurry mixed with pigment to match the shade of granite stone complete as per specifications andas per direction of engineer-in-charge. 15 Extra for Red/ Raw Silk/ Tan Brown/ Jet Black granite Stone 16 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 17 Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge. 18 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in- Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Epoxy injection grout in concrete/RCC work of approved make. 19 Providing and applying crystalline mortar by mixing in the ratio of 4.5: 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 ?45 MPa and adhesive bond strength Class R3 ?1.5 MPa. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. 20 Strengthening of existing open cell metal false ceiling by clipping assembled cell ceiling panels into extra U-profile carriers (as per requirement) in Galvanized Mild steel, pre-coated in black enamelled finish. In addition to the carriers, extra C-profile wire clips shall be fixed to hold the cell ceiling panels into the carriers for strengthening. Further, for lateral strengthening,extra angles made out of Galvanized Mild steel shall be fixed for cross connection with U-profile carriers. Payment shall be made on the basis of unit plan area measured. This item includes all material, labour, night charges, scaffolding, transportation, taxes etc. 21 Providing and fixing 12 mm thick partition/doors assembly of solid acrylic material with stainless steel hardware complete in toilets. 22 Providing and fixing backlit or high quality flex prints of high resolutionimages and to be pasted or installed on the walls or any other surfaces,of approved size and design as directed by the Architect. Necessaryframework in wood or aluminium to be provided for mounting of flex panel asrequired or as directed by the Architect. Flex panel to be installed takingutmost care to avoid any damages or stains on walls etc. In case of theinstallation or printing is found unsatisfactory the sheet to be replaced withnew with necessary corrections as part of rectification works. Item to includeall necessary tools, Flex and printing, framework for mounting of flex panelscaffolding if required etc. complete 23 Providing and fixing Small Size MDF Bases for mounting Sculptures of required sizes and design as directed by the Architect. Base to be made using 19mm MDF sheets including necessary wooden framework if required and finished with Duco paint of approved shade and type as directed by the Architect. Item to include all necessary tools, hardware etc complete in all respects. 24 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 25 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 26 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 27 Providing and fixing 8mm thick Black Painted Toughened Glass Clading on walls of required size and design as directed by the Architect. 8mm thick Marine Plywood backing to be provided behind the glass, to be fixed over 25mm x 25mm teak wood framework fixed to wall @ 1.2M c/c or as required as per site conditions. Item to include providing necessary lipping to hold glass in place, tools, hardware etc. to complete item in all respects. 28 Manufacturing, supplying and Fixing retroreflective overhead signage boards made up of 2mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retroreflective sheeting confirming to type III of ASTM-D-4956-01 as approved by Engineer-In-Charge, letters, borders etc. as per IRC:67-2001 in silver white with blue color background and with high intensity grade, pasted on substraight by pressure sensitive adhesive backing which shall be activated by applying pressure confirming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts and nuts @ 300mm centre to centre all along the periphery as well as in 02 vertical rows along with theft resistantmeasures, including the cost of painting with two OR more coats of epoxy paint in grey color on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specifications and directions of the Engineer-In-Charge. (Structural Frame work Including M.S Plate to be provided seperately. Rectangular area of the sheet only shall be measured for payment). 29 ILLUMINATED SIGNS:Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per relvant drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-In-Charge. 30 SIGN FRAME:-The sign frame shall be made out of aluminium extruded sections fabricated to required sizes and shape. Item to include providing and fixing of aluminium channel spot welded to sign frame including channel supports are to be powder coated to match as per apptoved colour or in colour duly approved by Engineer-In-Charge. The inside edge of sign frame to have EPDM gasket where it gets in contact with the sign panel as per approved design is required.All powder coating shall be done on all internal as well as external surafaces. The Sign shall be internally lit with the specified luminare (LED MODULE) and item to include providing and fixing luminare and fixtures comple as per the technical specifications for electrical works. 31 SIGN PANEL:- For elevated and underground stations.Providing and fixing sign pannel made out of 04mm thick polycarboate sheeting with vinyl message (3630/7725 series 03M OR equivalent) to required sixe and shape. Vinyl colour to match graphics and text as per schedule and pasted on sign panel. All the confont in the signage will be plotter cut/screen printing. The signage will be laminated for the protection of plotter cut vinyl pasted on sign panel. For double side 32 REFLECTOR PANEL:- Item to include providing and fixing embosed aluminium mirror reflector panel as per approved specifications and make, with provision to hold luminaries in position. 33 BACK PANEL:- For elevated and underground stations.For single sided signs, where graphics/text is to be on 01 side. Item to include providing in embosed radiant mirror reflector, back panel to be pure polyster coated to match as per approved colour as per technical specifications.ACCESSORIES:- Providing and fixing all accessories such as magnetic catchers, hinges, spring clips, anchoring hooks, nuts, cleats, screw hooks and slots etc complete as per specified fabrication drawing. All anchor fastener, bolts etc to be SS-304 Grade.Above description holds good for the following signage unless otherwise specified except for modifications due to their respective finished dimensions and fixing arrangement OR unless otherwise specified. 34 ILLUMINATED FACE MOUNTED SIGN:- (At Height of Roof at Entry/Exit and at room height of Underground Metro Stations Badi Chaupar and Chhoti Chaupar)The sign frame is to be mounted on BRICK/RCC wall backing with cladded or Non cladded.Item to include aluminium sign frame of required size and shape including mounting the sign frame on the RCC/BRICK wall backing by drilling holes of required diameter in the RCC/Brick Wall and achoring the sign frame using HILTI FASTENERS or Equivalent or specified size and length and providing and fixing all item and accesaories including silicon sealant and backer rod of approved make complete as per drawing for following panel sizes. The mounting surfacesshall be required and finished as per surrounding area complete at no extra cost. This sign is to be necessarily signle sided only. All achor fasteners, bolts etc to be SS-304 Grade. (SIZE: 2400mmX900mm Approx. OR 5200mmX1000mm Approx. Depth of SIGN DEPTH: 75mm OR as approved by EIC) 35 Supply and Installation of Vinyl Sheet (03M) in UV Print on existing signages at metro stations of Jaipur Metro. 36 Providing and fixing 120 minutes steel fire rated doors as per detailed specifiction made by shakti mate, Godrej etc. Along with hinge and door closer as per nfpa 80 and as per NFPA 252, temperture increase on the unexposed surface not exceeding on average 361.c (650.F) during first 30 mins of test size as per directions of Engineer in charge. 37 Re-alignment of misaligned doors by taking out the door and the door frame (as per site requiement), rectifying and re-fixing of the same. The door shall be made good using any fixtures required (except hinges, door closer, trim paces, panic bars) and nithing shall be paid extra in line of the same. The work shall be carried out as per the direction of Engineeer in charge. 38 Removing of old paint, rust with help of power tool and preparing the surface to various standards (ASA 3.0) before application of primer. The rate will include all tools, plants, labour and other consumables and incidental charges. Nothing shall be paid extra. Except NBSR no.1, 3,4,5 and 6. The surface which are not accessible with the help of power tool shall be prepared with wire brush. 39 Applying surface tolerant epoxy coating in two coats with epoxy based primer with minimum DFT of 200 microns at all locations wherever required and volume of solids not less than 75%. Paint is to be applied with spray painting, in place where its inaccessible it may be applied with brush (item to be used where surface is having scaling.) 40 Application of finishing coat epoxy polyurethane system of approved quality brand ot UV resistant coat at all locations and colour to achieve smooth & even surface with minimum volume of solids 57% and of 75 microns thickness of surfaces. 41 Providing and fixing of Anti Birds Spikesmade of high quality of Poly Carbonate, 5 Row 304 mm. Rates are inclusive of screws, cable ties, adhesives, fasteners up to 5 meter Height complete as per direction of Engineer-in-Charge. 42 Supply 5-7.5 HP submersible pump of discharge capacity 50-60 kl/hrs including cost of operation etc complete. 43 Cladding Work 44 Granite cladding work : Providing and laying 30 mm thick mirror polished Sadarhalli Grey/Cheema Pink/Jhalore Beige granite stone work of up to and including sizes of 1200mmX600mm of approved colour/ pattern with 4mm groove all around at all levels for wall linings/ columns/ cladding/skirtings (veneer work) by mechanical arrangement with SS cramps/ brackets, anchor bolts, 6 mm vertical SS pins of approved make and inserts as per drawings and specifications. The cost of making necessary grooves all around stone pieces, chamfering of corner edges and polishing are included. 45 Extra for Red/ Raw Silk/ Tan Brown/ Jet Black granite 46 Removal of old expansion joint, repair of site and providing & fixing of BITUFLEX close cell form twice for overlaping of close cell form joints filling of POLYDEEN GROUTFAST or equivalent non curing mortar and applying POYDEE liquid membrane or equivalent on the entire area of expansion joint mfg by M/S Greensboro Polychem Pvt. Ltd Or equivalent and fixing of 6 mm thick and 150 mm wide aluminium sheet one with sliding screw complete as per direction of Engineer- In-Charge 47 Polishing and buffing of SS 304 railing/SS surface provided in metro stations with minor grinding(as required) and removing stains/blemish with proper rubbing and polishing. The surface with suitable material and finally buffing the surface with high speed buffing machine using buffing material complete as per dierection of Engineer In Charge. The work will be carried out in non revanue hours and rates are inclusive of all taxes man power material, tools and plants, CO and OH etc all complete. 48 Providing skilled manpower such as welder/fitter for welding works along with welding machine to carry out welding as per direction of Engineer-In-charge including cost of tools, safety equipments,consumable(electrodes) etc. 49 Providing semiskilled manpower such as Plumber/carpentor/mason/ for plumbing/sewerage/carpentory/masonary, rectification works with all required T&P complete as per direction of Engineer-In-charge. 50 Providing unskilled manpower such as helper/beldar etc for miscelleneous Civil works with all required T&P as per direction of Engineer-In-charge. 51 Supply of potable water through water tankers o capacity 5000 liters at stations of JMRC from MSOR-BICP
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
TenderDetail
Loading tenders